WorldWideScience

Sample records for implanted tilting disc

  1. Retinal Nerve Fiber Layer Protrusion Associated with Tilted Optic Discs.

    Science.gov (United States)

    Chiang, Jaclyn; Yapp, Michael; Ly, Angelica; Hennessy, Michael P; Kalloniatis, Michael; Zangerl, Barbara

    2018-03-01

    This study resulted in the identification of an optic nerve head (ONH) feature associated with tilted optic discs, which might potentially contribute to ONH pathologies. Knowledge of such findings will enhance clinical insights and drive future opportunities to understand disease processes related to tilted optic discs. The aim of this study was to identify novel retinal nerve fiber layer (RNFL) anomalies by evaluating tilted optic discs using optical coherence tomography. An observed retinal nerve fiber protrusion was further investigated for association with other morphological or functional parameters. A retrospective review of 400 randomly selected adult patients with ONH examinations was conducted in a referral-only, diagnostic imaging center. After excluding other ONH pathologies, 215 patients were enrolled and evaluated for optic disc tilt and/or torsion. Gross anatomical ONH features, including size and rim or parapapillary region elevation, were assessed with stereoscopic fundus photography. Optical coherence tomography provided detailed morphological information of individual retinal layers. Statistical analysis was applied to identify significant changes between individual patient cohorts. A dome-shaped hyperreflective RNFL bulge, protruding into the neurosensory retina at the optic disc margins, was identified in 17 eyes with tilted optic discs. Available follow-up data were inconclusive regarding natural changes with this ONH feature. This RNFL herniation was significantly correlated with smaller than average optic disc size (P = .005), congenital disc tilt (P optic discs, which has not previously been assessed as an independent ONH structure. The feature is predominantly related to congenital crowded, small optic discs and variable between patients. This study is an important first step to elucidate diagnostic capabilities of tilted disc morphological changes and understanding associated functional deficits.

  2. Serous Macular Detachment Associated with Dome-Shaped Macula and Tilted Disc

    Directory of Open Access Journals (Sweden)

    Diamar Pardo-López

    2011-03-01

    Full Text Available Introduction: An entirely new type of staphyloma has been recently described as dome-shaped macula (DSM. It is characterized by an abnormal convex macular contour within the concavity of a posterior staphyloma. We found DSM associated with serous macular detachment (SMD and tilted disc in two consecutive cases. Case Reports: Case 1: A 37-year-old female presented to our department because of sudden onset blurred vision in her right eye (OD. The best-corrected visual acuity (BCVA was 0.5 in both eyes. Funduscopy evidenced bilateral tilted disc associated with posterior staphyloma. Optical coherence tomography (OCT demonstrated a DSM with SMD in her OD. After 15 months of follow-up, BCVA of her OD remained stable with chronic SMD. Case 2: A 32-year-old female presented to our department because of blurred vision in her OD. The BCVA was 0.4 in the OD and 1.0 in the left eye (OS. Bilateral tilted disc and posterior staphyloma were evidenced in the funduscopy. OCT demonstrated a bilateral DSM with SMD in her OD. After 45 months of follow-up, two further episodes of transient SMD were observed in her OD and seven in her OS. The final BCVA was 0.63 in the OD and 0.8 in the OS. Discussion: SMD associated with tilted disc constitutes a potential cause of subretinal fluid accumulation in myopic patients. OCT is essential for the detection of both SMD and DSM.

  3. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  4. Two-dimensional FSI simulation of closing dynamics of a tilting disc mechanical heart valve.

    Science.gov (United States)

    Govindarajan, V; Udaykumar, H S; Herbertson, L H; Deutsch, S; Manning, K B; Chandran, K B

    2010-03-01

    The fluid dynamics during valve closure resulting in high shear flows and large residence times of particles has been implicated in platelet activation and thrombus formation in mechanical heart valves. Our previous studies with bi-leaflet valves have shown that large shear stresses induced in the gap between the leaflet edge and the valve housing results in relatively high platelet activation levels whereas flow between the leaflets results in shed vortices not conducive to platelet damage. In this study we compare the result of closing dynamics of a tilting disc valve with that of a bi-leaflet valve. The two-dimensional fluid-structure interaction analysis of a tilting disc valve closure mechanics is performed with a fixed grid Cartesian mesh flow solver with local mesh refinement, and a Lagrangian particle dynamic analysis for computation of potential for platelet activation. Throughout the simulation the flow remains in the laminar regime and the flow through the gap width is marked by the development of a shear layer which separates from the leaflet downstream of the valve. Zones of re-circulation are observed in the gap between the leaflet edge and the valve housing on the major orifice region of the tilting disc valve and are seen to be migrating towards the minor orifice region. Jet flow is observed at the minor orifice region and a vortex is formed which sheds in the direction of fluid motion as observed in experiments using PIV measurements. The activation parameter computed for the tilting disc valve, at the time of closure was found to be 2.7 times greater than that of the bi-leaflet mechanical valve and was found to be in the vicinity of the minor orifice region mainly due to the migration of vortical structures from the major to the minor orifice region during the leaflet rebound of the closing phase.

  5. Ranibizumab in the treatment of choroidal neovascularization on the border of an inferior staphyloma associated with tilted disc syndrome

    Directory of Open Access Journals (Sweden)

    Luis Arias

    2010-03-01

    Full Text Available Luis Arias1,2, Jordi Monés21Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Barcelona; 2Institut de la Màcula i de la Retina, Centro Médico Teknon, BarcelonaPurpose: To describe a case of choroidal neovascularization (CNV on the border of an inferior staphyloma associated with tilted disc syndrome treated with intravitreal ranibizumab.Patients: Observational case report.Methods: A patient with CNV on the border of an inferior staphyloma associated with tilted disc syndrome was imaged using fluorescein angiography, autofluorescence and spectral domain optical coherence tomography, and treated with intravitreal injections of ranibizumab. Results: The patient received 3 ranibizumab injections during the 9-month follow-up. The visual acuity improved from 20/40 to 20/32 and the foveal thickness reduced from 470 microns to 248 microns. The angiograms showed resolution of leakage associated with CNV. There were no adverse events.Conclusion: Intravitreal ranibizumab is an efficacious and safe treatment in the management of choroidal neovascularization on the border of an inferior staphyloma associated with tilted disc syndrome.Keywords: intravitreal ranibizumab, choroidal neovascularization, tilted disc syndrome, inferior staphyloma

  6. Transient analysis for a system with a tilted disc check valve

    International Nuclear Information System (INIS)

    Jeung, Jaesik; Lee, Kyukwang; Cho, Daegwan

    2014-01-01

    Check valves are used to prevent reverse flow conditions in a variety of systems in nuclear power plants. When a check valve is closed by a reverse flow, the transient load can jeopardize the structural integrity on the piping system and its supports. It may also damage intended function of the in-line components even though the severity of the load differs and depends strongly on types of the check valves. To incorporate the transient load in the piping system, it is very important to properly predict the system response to transients such as a check valve closure accompanied by pump trip and to evaluate the system transient. The one-dimensional transient simulation codes such as the RELAP5/MOD3.3 and TRACE were used. There has not been a single model that integrates the two codes to handle the behavior of a tilted disc check valve, which is designed to mitigate check valve slams by shorting the travel of the disc. In this paper a model is presented to predict the dynamic motion of a tilted disc check valve in the transient simulation using the RELAP5/MOD3.3 code and the model is incorporated in a system transient analysis using control variables of the code. In addition, transient analysis for Essential Service Water (ESW) system is performed using the proposed model and the associated load is evaluated for the system. (author)

  7. Comparison of marginal bone loss and implant success between axial and tilted implants in maxillary All-on-4 treatment concept rehabilitations after 5 years of follow-up.

    Science.gov (United States)

    Hopp, Milena; de Araújo Nobre, Miguel; Maló, Paulo

    2017-10-01

    There is need for more scientific and clinical information on longer-term outcomes of tilted implants compared to implants inserted in an axial position. Comparison of marginal bone loss and implant success after a 5-year follow-up between axial and tilted implants inserted for full-arch maxillary rehabilitation. The retrospective clinical study included 891 patients with 3564 maxillary implants rehabilitated according to the All-on-4 treatment concept. The follow-up time was 5 years. Linear mixed-effect models were performed to analyze the influence of implant orientation (axial/tilted) on marginal bone loss and binary logistic regression to assess the effect of patient characteristics on occurrence of marginal bone loss >2.8 mm. Only those patients with measurements of at least one axial and one tilted implant available were analyzed. This resulted in a data set of 2379 implants (1201 axial, 1178 tilted) in 626 patients (=reduced data set). Axial and tilted implants showed comparable mean marginal bone losses of 1.14 ± 0.71 and 1.19 ± 0.82 mm, respectively. Mixed model analysis indicated that marginal bone loss levels at 5 years follow up was not significantly affected by the orientation (axial/tilted) of the implants in the maxillary bone. Smoking and female gender were associated with marginal bone loss >2.8 mm in a logistic regression analysis. Five-year implant success rates were 96%. The occurrence of implant failure showed to be statistically independent from orientation. Within the limitations of this study and considering a follow-up time of 5 years, it can be concluded that tilted implants behave similarly with regards to marginal bone loss and implant success in comparison to axial implants in full-arch rehabilitation of the maxilla. Longer-term outcomes (10 years +) are needed to verify this result. © 2017 Wiley Periodicals, Inc.

  8. A prospective, split-mouth study comparing tilted implants with angulated connection versus conventional implants with angulated abutment.

    Science.gov (United States)

    Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan

    2017-12-01

    An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce the amount of plaque. © 2017 Wiley Periodicals, Inc.

  9. Antimetropia in a 10-year-old boy with unilateral tilted disc syndrome

    Directory of Open Access Journals (Sweden)

    Makino S

    2014-05-01

    Full Text Available Shinji MakinoDepartment of Ophthalmology, Jichi Medical University, Shimotsuke, Tochigi, JapanAbstract: Antimetropia is a condition in which one eye is myopic, while the fellow eye is hyperopic. This report describes a case of antimetropia associated with unilateral tilted disc syndrome. A 10-year-old boy presented with the complaint of diminished vision for distant objects in his right eye for several months. His uncorrected distance visual acuity was 0.15 in the right eye and 1.0 in the left eye. Best corrected visual acuity was 1.0, with -6.00 D/-2.00 D 170° in the right eye and +1.50 D in the left eye. The cover test revealed right esotropia and hypertropia. Bifoveal fixation was achieved using a 14 prism diopter (PD base at 220° in the right eye. Fundus examination revealed a tilted disc with inferior staphyloma in the right eye, but no abnormal findings were observed in the left eye. In addition, the patient occasionally experienced diplopia under casual viewing conditions. A cycloplegic refraction revealed -6.00 D/-2.00 D 170° in the right eye and +1.50 D/-2.00 D 5° in the left eye. Thus, prism glasses were prescribed. While wearing the prism glasses, the patient has shown no diplopia and maintains good binocular function.Keywords: amblyopia, strabismus, anisometropia, staphyloma

  10. Optic disc and peripapillary retinal nerve fiber layer characteristics associated with glaucomatous optic disc in young myopia.

    Science.gov (United States)

    Lee, Jong Eun; Sung, Kyung Rim; Park, Ji Min; Yoon, Joo Young; Kang, Sung Yong; Park, Sung Bae; Koo, Hyung Jin

    2017-03-01

    To explore optic disc and peripapillary retinal nerve fiber layer (RNFL) features associated with glaucomatous optic disc (GOD) in young myopia. Presence of GOD, optic disc tilt, and disc torsion were determined using fundus photographs. If the measured disc tilt ratio was >1.3, the optic disc was classified as tilted. Optic disc torsion was defined as a >15° deviation in the long axis of the optic disc from the vertical meridian. The average and four quadrants RNFL thicknesses were assessed using spectral domain optical coherence tomography (SD-OCT). Logistic regression analyses were performed to identify factors associated with the presence of GOD. Nine hundred and sixty myopic subjects were recruited from four refractive surgery clinic databases. The mean age was 26.6 ± 5.7 years and spherical equivalent (SE) was -5.5 ± 2.5 diopters. Among 960 eyes, 26 (2.7%) received GOD group classification. Among 934 normal eyes, 290 (31.0%) had titled optic discs. Eighteen eyes (69.2%) in the GOD group had tilted optic discs. When compared to normal eyes, the GOD group had significantly higher tilt ratios (1.4 ± 0.2 vs. 1.2 ± 0.1, p Optic disc tilt was found in approximately one-third of young myopic eyes and was independently associated with the presence of GOD.

  11. Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    Science.gov (United States)

    Fortin, Yvan; Sullivan, Richard M

    2017-02-01

    Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. Consecutive patients presenting for either routine hygiene maintenance or unplanned emergency care who had received tilted implants as a sinus graft alternative to support fixed fully implant-supported restoration of an edentulous maxilla and were followed for a minimum of 10 years from initial implant placement were included in this evaluation. Forty-four patients were identified: 40 with bilateral tilted implants and 4 with one tilted and one axial posterior implant. Eight patients received one-piece fixed porcelain-to-gold screw-retained restorations, and thirty-six patients received a fully implant-supported patient-removable Marius Bridge. Seventy-nine out of 84 originally loaded posterior tilted implants survived a minimum of 10 years loading; one tilted implant was lost at 10 years. Eight additional posterior implants were placed for either these lost tilted posterior implants or as proactive supplemental support; one of these replacement tilted implants survived for at least 10 years and is included in the data. All patients have maintained continuous fixed function throughout the follow-up period. Forty-one out of 44 patients continue with the original restoration, 33 without modification or removal of the fixed restoration or implant-connecting bar. One porcelain-to-gold and seven Marius Bridges had framework modifications to accommodate additional implants; 3 Marius Bridge restorations were replaced with a newer generation. Within the limits of this retrospective study, the results show that continuous fixed function of fully implant-supported maxillary restorations using posterior tilted implants in terminal positions of support as a sinus graft alternative combined with axial anterior implants is possible over a prolonged period. Loss of a posterior

  12. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  13. Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae.

    Science.gov (United States)

    Wentaschek, Stefan; Lehmann, Karl Martin; Scheller, Herbert; Weibrich, Gernot; Behneke, Nikolaus

    2016-01-01

    The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12-16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).

  14. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    Directory of Open Access Journals (Sweden)

    Yue JJ

    2016-05-01

    Full Text Available James J Yue,1 Rolando Garcia Jr,2 Larry E Miller3 1Department of Orthopaedic Surgery, Yale School of Medicine, New Haven, CT, 2Orthopedic Care Center, Miami, FL, 3Miller Scientific Consulting, Inc., Asheville, NC, USA Abstract: Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval - the activL® Artificial Disc (Aesculap Implant Systems. Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. Keywords: activL® Artificial Disc, artificial disc, degenerative disc disease, discogenic, implant, lumbar, motion preservation, pain

  15. Combination of straight and tilted implants for supporting screw-retained dental prostheses in atrophic posterior maxillae: A 2-year prospective study.

    Science.gov (United States)

    Casar-Espinosa, Juan-Carlos; Castillo-Oyagüe, Raquel; Serrera-Figallo, María Ángeles; Garrido-Serrano, Roberto; Lynch, Christopher D; Menéndez-Collar, Manuel; Torres-Lagares, Daniel; Gutiérrez-Pérez, José-Luis

    2017-08-01

    To evaluate the two-year survival rate (SR) and marginal bone loss (MBL) of fixed dental prostheses (FDPs) supported by straight (S) and tilted (T) implants under the influence of diverse study variables. A prospective investigation comprising 21 patients provided with a total of 27 maxillary screw-retained restorations fixed to 70 dental implants was developed. Two groups of implants were considered depending on their inclination with respect to the occlusal plane: Group 1 (S, n=37): straight/axial implants and Group 2 (T, n=33): tilted/angled fixations. Each FDP was supported by a combination of S and T implants. SR and MBL were assessed at the time of loading and two years after surgery. Patient-, surgical- and/or rehabilitation-related information was gathered. Data were statistically analysed at the α=0.05 significance level. After 24 months, a 100% SR was achieved and the MBL of S and T implants were statistically similar. T implants located in the molar region showed lower MBL than did those replacing premolars (p=0.031). Upright and angled fixations inserted at posterior maxillary areas resulted in comparable survival rates and peri-implant MBL after two years. The marginal bone resorption around tilted implants depended on their location. Screw-retained restorations fixed to straight and tilted implants seem to be a safe treatment option in posterior atrophic maxillae. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    Science.gov (United States)

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  17. Tilted Implants for Full-Arch Rehabilitations in Completely Edentulous Maxilla: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2012-01-01

    Full Text Available Purpose. The aims of this study were to assess the treatment outcome of immediately loaded full-arch fixed bridges anchored to both tilted and axially placed implants in the edentulous maxilla and to evaluate the incidence of biological and prosthetic complications. Materials and Methods. Thirty-four patients (18 women and 16 men were included in the study. Each patient received a maxillary full-arch fixed bridge supported by two axial implants and two distal tilted implants. A total of 136 implants were inserted. Loading was applied within 48 hours of surgery and definitive restorations were placed 4 to 6 months later. Patients were scheduled for followup at 6, 12, 18, and 24 months and annually up to 5 years. At each followup plaque level and bleeding scores were assessed and every complication was recorded. Results. The overall follow-up range was 12 to 73 months (mean 38.8 months. No implant failures were recorded to date, leading to a cumulative implant survival rate of 100%. Biological complications were recorded such as alveolar mucositis (11.8% patients, peri-implantitis (5.9% patients, and temporomandibular joint pain (5.9% patients. The most common prosthetic complications were the fracture or detachment of one or multiple acrylic teeth in both the temporary (20.6% patients and definitive (17.7% patients prosthesis and the minor acrylic fractures in the temporary (14.7% patients and definitive (2.9% patients prosthesis. Hygienic complications occurred in 38.2% patients. No patients’ dissatisfactions were recorded. Conclusions. The high cumulative implant survival rate indicates that this technique could be considered a viable treatment option. An effective recall program is important to early intercept and correct prosthetic and biologic complications in order to avoid implant and prosthetic failures.

  18. Heterotopic ossification associated with myelopathy following cervical disc prosthesis implantation.

    Science.gov (United States)

    Wenger, Markus; Markwalder, Thomas-Marc

    2016-04-01

    This case report presents a 37-year-old man with clinical signs of myelopathy almost 9 years after implantation of a Bryan disc prosthesis (Medtronic Sofamor Danek, Memphis, TN, USA) for C5/C6 soft disc herniation. As demonstrated on MRI and CT scan, spinal cord compression was caused by bony spurs due to heterotopic ossification posterior to the still moving prosthesis. The device, as well as the ectopic bone deposits, had to be removed because of myelopathy and its imminent aggravation. Conversion to anterior spondylodesis was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. PEG modulated release of etanidazole from implantable PLGA/PDLA discs.

    Science.gov (United States)

    Wang, Fangjing; Lee, Timothy; Wang, Chi-Hwa

    2002-09-01

    In this work, etanidazole (one type of hypoxic radiosensitizer) is encapsulated into spray dried poly(D),L-lactide-co-glycolide) (PLGA) microspheres and then compressed into discs for controlled release applications. Etanidazole is characterized by intracellular glutathione depletion and glutathione transferases inhibition, thereby enhancing sensitivity to radiation. It is also cytotoxic to tumor cells and can chemosensitize some alkylating agents by activating their tumor cell killing capabilities. We observed the release characteristics of etanidazole in the dosage forms of microspheres and discs, subjected to different preparation conditions. The release characteristics, morphology changes, particle size, and encapsulation efficiency of microspheres are also investigated. The release rate of etanidazole from implantable discs (13 mm in diameter, 1 mm in thickness, fabricated by a press) is much lower than microspheres due to the reduced specific surface. After the initial burst of 1% release for the first day, the cumulative release within the first week is less than 2% until a secondary burst of release (caused by polymer degradation) occurs after one month. Some key preparation conditions such as drug loadings, disc thickness and diameter, and compression pressure can affect the initial burst of etanidazole from the discs. However, none of them can significantly make the release more uniform. In contrast, the incorporation of polyethylene glycol (PEG) can greatly enhance the release rate of discs and also reduces the secondary burst effect, thereby achieving a sustained release for about 2 months.

  20. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  1. Research Regarding the Manufacturing through AM Technologies of an Implant for Cervical Disc Replacement

    Directory of Open Access Journals (Sweden)

    Miron-Borzan Cristina Stefana

    2017-01-01

    Full Text Available Worldwide, accidents are one of the main causes of illness in developed and undeveloped socio-economic countries. Additive Manufacturing (AM technologies bring extremely useful and advantageous applications for the new neurosurgical procedures. Because the surgical insertion of devices for cervical disc replacement is very difficult, the development of new devices that can minimize these disadvantages, are needed. The aim of this paper was to improve the characteristics of an implant for cervical intervertebral disc replacement, a model based on an existing implant. A cervical cage designed for stabilization and arthrodesis between the cervical vertebrae was analyzed. A new design of a cage that have some improvements, useful for patient safety, as well as for facilitating the surgery was developed. The new proposed design was verified through Fine Element Analysis.

  2. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

    Science.gov (United States)

    Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto

    2012-05-01

    Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.

  3. Complete Transversal Disc Fracture in a Björk-Shiley Delrin Mitral Valve Prosthesis 43 Years After Implantation.

    Science.gov (United States)

    González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier

    2016-10-01

    A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. 2D Bayesian automated tilted-ring fitting of disc galaxies in large H I galaxy surveys: 2DBAT

    Science.gov (United States)

    Oh, Se-Heon; Staveley-Smith, Lister; Spekkens, Kristine; Kamphuis, Peter; Koribalski, Bärbel S.

    2018-01-01

    We present a novel algorithm based on a Bayesian method for 2D tilted-ring analysis of disc galaxy velocity fields. Compared to the conventional algorithms based on a chi-squared minimization procedure, this new Bayesian-based algorithm suffers less from local minima of the model parameters even with highly multimodal posterior distributions. Moreover, the Bayesian analysis, implemented via Markov Chain Monte Carlo sampling, only requires broad ranges of posterior distributions of the parameters, which makes the fitting procedure fully automated. This feature will be essential when performing kinematic analysis on the large number of resolved galaxies expected to be detected in neutral hydrogen (H I) surveys with the Square Kilometre Array and its pathfinders. The so-called 2D Bayesian Automated Tilted-ring fitter (2DBAT) implements Bayesian fits of 2D tilted-ring models in order to derive rotation curves of galaxies. We explore 2DBAT performance on (a) artificial H I data cubes built based on representative rotation curves of intermediate-mass and massive spiral galaxies, and (b) Australia Telescope Compact Array H I data from the Local Volume H I Survey. We find that 2DBAT works best for well-resolved galaxies with intermediate inclinations (20° < i < 70°), complementing 3D techniques better suited to modelling inclined galaxies.

  5. Upper full arch rehabilitation with sinus by-pass with tilted implants via tapered-threaded expanders in low density bone: a clinical trial.

    Science.gov (United States)

    Andreasi Bassi, M; Andrisani, C; Lico, S; Ormanier, Z; Arcuri, C

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants, in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors present a case series of full-arch rehabilitations performed with this procedure named: Tilted Implant Expansion Osteotomy (TIEO). 12 patients (5 males and 7 females, average age 58.5 ± 8.1 years) with totally or partially edentulous maxilla were enrolled in this study. For each patient 4 implants were placed, the anterior implants in the area of lateral incisors or canines while, the posterior implants, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 48 cylindrical two-piece implants were placed, 24 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 6 months, the second stage surgery was performed. The cases were finalized by means of a hybrid metal-acrylic prosthesis. The post finalization follow-up was at 12 months. Survival rate was 100% since none fixtures were lost. At the one-year follow up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for full-arch rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  6. Acquired spondylolysis after implantation of a lumbar ProDisc II prosthesis: case report and review of the literature.

    Science.gov (United States)

    Schulte, Tobias L; Lerner, Thomas; Hackenberg, Lars; Liljenqvist, Ulf; Bullmann, Viola

    2007-10-15

    A case of acquired lumbar spondylolysis following lumbar disc arthroplasty L5-S1 in an 40-year-old woman and review of the literature. To present and discuss a case of acquired lumbar spondylolysis after implantation of an artificial disc L5-S1 that may have impaired a good clinical result requiring additional posterior lumbar instrumentation and fusion in order to improve understanding of this condition and to propose an effective method of surgical management. Lumbar disc arthroplasty is a possible surgical option for patients with degenerative disc disease. Acquired spondylolysis is a rare but known complication of spinal fusion but has never been described as a consequence of mobile disc arthroplasty. The authors present the first case in the literature who developed this complication. A 40-year-old woman with severe osteochondrosis L5-S1 and discogenic lumbar back pain underwent implantation of an artificial disc. Surgery and postoperative course were uneventful and the patient improved significantly as for back pain and mobility. Eighteen months after surgery, the patient was again admitted to our outpatient clinic for back pain that had slowly increased over time. The radiologic workup showed a new spondylolysis L5 without a spondylolisthesis. Because of unsuccessful conservative treatment, the patient underwent posterior lumbar instrumentation and fusion L5-S1, leading to a significant pain reduction and a good clinical outcome. Spine surgeons should be aware of the possibility of lumbar disc arthroplasty to induce acquired spondylolysis impairing good clinical results.

  7. Maxillary sinus by-pass with tilted implants via tapered-screw bone expanders in low density bone: one year follow -up of a case series.

    Science.gov (United States)

    Andreasi Bassi, M; Andrisani, C; Lopez, M A; Gaudio, R M; Lombardo, L; Lauritano, D

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors named the procedure: Tilted Implant Expansion Osteotomy (TIEO). Fifteen patients (10 females and 5 males, mean age 47.8±8.15 years) with distal edentulous maxillae were enrolled in this study. For each edentulous site 2 implants were placed, the anterior implant in the area of the most anterior missing tooth while, the posterior implant, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 34 cylindrical two-piece implants were placed, 17 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 4-6 months, the second stage surgery was performed. The cases were finalized by metal-ceramic cementable restorations with a variable number of elements, from 2 to 4, without any cantilever element. The post finalization follow-up was at 12 months. Survival rate was 100% since no fixtures were lost. At the one-year follow-up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for oral rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  8. ASSOCIATION OF SPINOPELVIC PARAMETERS WITH THE LOCATION OF LUMBAR DISC HERNIATION

    OpenAIRE

    Léo, Jefferson Coelho de; Léo, Álvaro Coelho de; Cardoso, Igor Machado; Jacob Júnior, Charbel; Batista Júnior, José Lucas

    2015-01-01

    Objective:To associate spinopelvic parameters, pelvic incidence, sacral slope, pelvic tilt and lumbar lordosis with the axial location of lumbar disc herniation.Methods:Retrospective study, which evaluated imaging and medical records of 61 patients with lumbar disc herniation, who underwent surgery with decompression and instrumented lumbar fusion in only one level. Pelvic incidence, sacral slope, pelvic tilt and lumbar lordosis with simple lumbopelvic lateral radiographs, which included the ...

  9. Saddle-fin cell transistors with oxide etch rate control by using tilted ion implantation (TIS-fin) for sub-50-nm DRAMs

    International Nuclear Information System (INIS)

    Yoo, Min Soo; Choi, Kang Sik; Sun, Woo Kyung

    2010-01-01

    As DRAM cell pitch size decreases, the need for a high performance transistor is increasing. Though saddle-fin (S-fin) transistors have superior characteristics, S-fin transistors are well known to be more sensitive to process variation. To make uniform S-fin transistors, for the first time, we developed a new fin formation method using tilted ion implantation along the wordline direction after a recess gate etch. Due to the increased etch rate of the oxide film by ion implantation damage, fins are made at the bottom channel of the recess gate after wet etching. The resulting tilt implanted saddle-fin (TIS-fin) transistor has remarkably improved characteristics, such as ∼8% subthreshold swing (SS) and a 40% drain induced barrier lowering (DIBL) decrease. Especially, the TIS-fin with a neutral dopant has a reduced threshold voltage (Vth) variation within a wafer (<100 mV), which is comparable with that of a mass-produced sphere-shaped recessed channel array transistor (SRCAT).

  10. Total disc replacement using tissue-engineered intervertebral discs in the canine cervical spine.

    Directory of Open Access Journals (Sweden)

    Yu Moriguchi

    Full Text Available The most common reason that adults in the United States see their physician is lower back or neck pain secondary to degenerative disc disease. To date, approaches to treat degenerative disc disease are confined to purely mechanical devices designed to either eliminate or enable flexibility of the diseased motion segment. Tissue engineered intervertebral discs (TE-IVDs have been proposed as an alternative approach and have shown promise in replacing native IVD in the rodent tail spine. Here we demonstrate the efficacy of our TE-IVDs in the canine cervical spine. TE-IVD components were constructed using adult canine annulus fibrosis and nucleus pulposus cells seeded into collagen and alginate hydrogels, respectively. Seeded gels were formed into a single disc unit using molds designed from the geometry of the canine spine. Skeletally mature beagles underwent discectomy with whole IVD resection at levels between C3/4 and C6/7, and were then divided into two groups that received only discectomy or discectomy followed by implantation of TE-IVD. Stably implanted TE-IVDs demonstrated significant retention of disc height and physiological hydration compared to discectomy control. Both 4-week and 16-week histological assessments demonstrated chondrocytic cells surrounded by proteoglycan-rich matrices in the NP and by fibrocartilaginous matrices in the AF portions of implanted TE-IVDs. Integration into host tissue was confirmed over 16 weeks without any signs of immune reaction. Despite the significant biomechanical demands of the beagle cervical spine, our stably implanted TE-IVDs maintained their position, structure and hydration as well as disc height over 16 weeks in vivo.

  11. The velocity ellipsoid in the Galactic disc using Gaia DR1

    Science.gov (United States)

    Anguiano, Borja; Majewski, Steven R.; Freeman, Kenneth C.; Mitschang, Arik W.; Smith, Martin C.

    2018-02-01

    The stellar velocity ellipsoid of the solar neighbour (d Standard of Rest in Galactic rotation to be V⊙ = 13.9 ± 3.4 km s-1. A relation is found between the vertex deviation and the chemical abundances for the thin disc, ranging from -5 to +40° as iron abundance increases. For the thick disc we find a vertex deviation of luv ˜- 15°. The tilt angle (luw) in the U-W plane for the thin disc groups ranges from -10 to +15°, but there is no evident relation between luw and the mean abundances. However, we find a weak relation for luw as a function of iron abundances and α-elements for most of the groups in the thick disc, where the tilt angle decreases from -5 to -20° when [Fe/H] decreases and [α/Fe] increases. The velocity anisotropy parameter is independent of the chemical group abundances and its value is nearly constant for both discs (β ˜ 0.5), suggesting that the combined disc is dynamically relaxed.

  12. ASSOCIATION OF SPINOPELVIC PARAMETERS WITH THE LOCATION OF LUMBAR DISC HERNIATION

    Directory of Open Access Journals (Sweden)

    Jefferson Coelho de Léo

    2015-09-01

    Full Text Available Objective:To associate spinopelvic parameters, pelvic incidence, sacral slope, pelvic tilt and lumbar lordosis with the axial location of lumbar disc herniation.Methods:Retrospective study, which evaluated imaging and medical records of 61 patients with lumbar disc herniation, who underwent surgery with decompression and instrumented lumbar fusion in only one level. Pelvic incidence, sacral slope, pelvic tilt and lumbar lordosis with simple lumbopelvic lateral radiographs, which included the lumbar spine, the sacrum and the proximal femur. The affected segment was identified as the level and location of lumbar disc herniation in the axial plane with MRI scans.Results:Of 61 patients, 29 (47.5% had low lumbar lordosis; in this group 24 (82.8% had central disc herniation, 4 (13.8% had lateral recess disc herniation and 1 (3.4% had extraforaminal disc herniation (p<0.05. Of the 61 patients, 18 (29.5% had low sacral slope; of this group 15 (83.3% had central disc herniation and 3 (16.7% had disc herniation in lateral recess (p<0.05.Conclusions:There is a trend towards greater load distribution in the anterior region of the spine when the spine has hypolordotic curve. This study found an association between low lordosis and central disc herniation, as well as low sacral slope and central disc herniation.

  13. [Influence of disc height on outcome of posterolateral fusion].

    Science.gov (United States)

    Drain, O; Lenoir, T; Dauzac, C; Rillardon, L; Guigui, P

    2008-09-01

    Experimentally, posterolateral fusion only provides incomplete control of flexion-extension, rotation and lateral inclination forces. The stability deficit increases with increasing height of the anterior intervertebral space, which for some warrants the adjunction of an intersomatic arthrodesis in addition to the posterolateral graft. Few studies have been devoted to the impact of disc height on the outcome of posterolateral fusion. The purpose of this work was to investigate the spinal segment immobilized by the posterolateral fusion: height of the anterior intervertebral space, the clinical and radiographic impact of changes in disc height, and the short- and long-term impact of disc height measured preoperatively on clinical and radiographic outcome. In order to obtain a homogeneous group of patients, the series was limited to patients undergoing posterolateral arthrodesis for degenerative spondylolisthesis, in combination with radicular release. This was a retrospective analysis of a consecutive series of 66 patients with mean 52 months follow-up (range 3-63 months). A dedicated self-administered questionnaire was used to collect data on pre- and postoperative function, the SF-36 quality of life score, and patient satisfaction. Pre- and postoperative (early, one year, last follow-up) radiographic data were recorded: olisthesic level, disc height, intervertebral angle, intervertebral mobility (angular, anteroposterior), and global measures of sagittal balance (thoracic kyphosis, lumbar lordosis, T9 sagittal tilt, pelvic version, pelvic incidence, sacral slope). SpineView was used for all measures. Univariate analysis searched for correlations between variation in disc height and early postoperative function and quality of fusion at last follow-up. Multivariate analysis was applied to the following preoperative parameters: intervertebral angle, disc height, intervertebral mobility, sagittal balance parameters, use of osteosynthesis or not. At the olisthesic

  14. In-situ photopolymerized and monitored implants: successful application to an intervertebral disc replacement

    Science.gov (United States)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2016-02-01

    Photopolymerization is a common method to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler by using ultra-violet light. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. We designed a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 500 μm in diameter. Using a combination of Raman and fluorescence spectroscopy, the current state of the photopolymerization was inferred and monitored in real time within an in-vitro tissue model. It was also possible to determine roughly the position of the probe within the tissue cavity by analysing the fluorescence signal. Using the technique hydrogels were successfully implanted into a bovine intervertebral disc model. Mechanical tests could not obstruct the functionality of the implant. Finally, the device was also used for other application such as the implantation of a hydrogel into an aneurysm tissue cavity which will be presented at the conference.

  15. The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration.

    Science.gov (United States)

    Kim, Yong Chan; Jung, Younhea; Park, Hae-Young Lopilly; Park, Chan Kee

    2017-07-19

    Tilted and rotated appearances are hallmarks of the myopic optic disc. As the eyeball grows axially, the posterior pole elongates not only globally but in a localized manner as well. In this process, the optic disc is pulled towards the deepest point of the elongated eyeball, which might result in a change in optic disc configuration. Thus, we hypothesized that analyzing the variation of posterior pole contour can play a major role in understanding optic disc configuration in myopic subjects. By analyzing consecutive images of swept source OCT coronal sections at the posterior pole, the deepest interface between Bruch's membrane and the choroid could be identified as the deepest point of the eyeball (DPE). The location and the properties of the DPE differed significantly between the 125 eyes of non-glaucomatous myopic group and the 40 eyes of non-glaucomatous emmetropic group classified based on 24 mm axial length. The results suggested that the larger disc to DPE angle and the larger disc to DPE depth strongly predicts the optic disc torsion degree and the optic disc tilt. Our findings suggest that identifying the posterior pole profile plays a major role in understanding the optic disc alterations found in myopic subjects.

  16. The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.

    Science.gov (United States)

    Wan, Zongmiao; Wang, Shaobai; Kozanek, Michal; Xia, Qun; Mansfield, Frederick L; Lü, Guohua; Wood, Kirkham B; Li, Guoan

    2012-03-01

    To evaluate the biomechanical effect of the X-Stop device on the intervertebral foramen (IVF) and segmental spinal canal length (SSCL), as well as the intervertebral disc space at the implanted and the adjacent segments in patients with lumbar spinal stenosis (LSS). Eight elderly patients with LSS, scheduled for X-stop implantation, were CT or MRI scanned to construct 3D vertebral models (L2-S1). Before and after the surgery, each patient was also imaged using a dual-fluoroscopic image system during weight-bearing standing and maximum extension-flexion. The positions of the vertebrae were then determined using an established 2D-3D model matching method. The data revealed that the postoperative IVF area was significantly increased by 32.9% (or 32 mm2) (pspace of the implanted level was significantly decreased from 8.0 to 6.6 mm during standing. The X-Stop implantation efficiently enlarged the IVF area in the elderly patients with LSS at the operated level with little biomechanical effect immediately on the superior and inferior adjacent levels. However, it reduced the anterior disc space at the implanted level.

  17. Evaluation of intervertebral disc regeneration with implantation of bone marrow mesenchymal stem cells (BMSCs) using quantitative T2 mapping: a study in rabbits.

    Science.gov (United States)

    Cai, Feng; Wu, Xiao-Tao; Xie, Xin-Hui; Wang, Feng; Hong, Xin; Zhuang, Su-Yang; Zhu, Lei; Rui, Yun-Feng; Shi, Rui

    2015-01-01

    The aim of the study was to investigate the curative effects of transplantation of bone marrow mesenchymal stem cells (BMSCs) on intervertebral disc regeneration and to investigate the feasibility of the quantitative T2 mapping method for evaluating repair of the nucleus pulposus after implantation of BMSCs. Forty-eight New Zealand white rabbits were used to establish the lumber disc degenerative model by stabbing the annulus fibrosus and then randomly divided into four groups, i.e. two weeks afterwards, BMSCs or phosphate-buffered saline (PBS) were transplanted into degenerative discs (BMSCs group and PBS group), while the operated rabbits without implantation of BMSCs or PBS served as the sham group and the rabbits without operation were used as the control group. At weeks two, six and ten after operation, the T2 values and disc height indices (DHI) were calculated by magnetic resonance imaging (MRI 3.0 T), and the gene expressions of type II collagen (COL2) and aggrecan (ACAN) in degenerative discs were evaluated by real-time reverse transcription polymerase chain reaction (RT-PCR). T2 values for the nucleus pulposus were correlated with ACAN or COL2 expression by regression analysis. Cell clusters, disorganised fibres, interlamellar glycosaminoglycan (GAG) matrix and vascularisation were observed in lumber degenerative discs. BMSCs could be found to survive in intervertebral discs and differentiate into nucleus pulposus-like cells expressing COL2 and ACAN. The gene expression of COL2 and ACAN increased during ten weeks after transplantation as well as the T2 signal intensity and T2 value. The DHI in the BMSCs group decreased more slowly than that in PBS and sham groups. The T2 value correlated significantly with the gene expression of ACAN and COL2 in the nucleus pulposus. Transplantation of BMSCs was able to promote the regeneration of degenerative discs. Quantitative and non-invasive T2 mapping could be used to evaluate the regeneration of the nucleus

  18. Optic Disc Change during Childhood Myopic Shift: Comparison between Eyes with an Enlarged Cup-To-Disc Ratio and Childhood Glaucoma Compared to Normal Myopic Eyes.

    Directory of Open Access Journals (Sweden)

    Hae-Young Lopilly Park

    Full Text Available Progressive disc tilting and the development or enlargement of peripapillary atrophy (PPA are observed during a myopic shift in children. This could be related to the changes around the optic nerve head during eyeball elongation. If the biomechanical properties at or around the optic nerve head are changed after exposure to elevated intraocular pressure (IOP in glaucoma eyes, different response of the disc tilting and PPA changes could take place during eyeball elongation by myopic shift. On the basis of this background, the aim of this study was to compare the morphological changes in the optic disc induced by a myopic shift during childhood between normal control eyes, eyes from disc suspects with an enlarged cup-to-disc ratio (CDR, and eyes with childhood glaucoma.Total of 82 eyes from 82 subjects younger than 14 years of age were included in the study. Serial disc photographs were classified into one of two groups: eyes with an optic nerve head (ONH or peripapillary atrophy (PPA change or without an ONH/PPA change. Using ImageJ software, the outlines of the optic disc and PPA were plotted, and the vertical disc diameter (VDD, horizontal disc diameter (HDD, and maximum PPA width (PPW were measured. The changes in the ratios of these parameters and the relationships between the degree of myopic shift or the ONH/PPA change were analyzed.Twenty-five eyes with normal optic disc appearance, 36 eyes with enlarged cup-to-disc ratio, and 21 eyes of glaucoma patients were analyzed. The initial intraocular pressure (IOP at diagnosis was significantly different among the groups (P<0.001. The degree of myopic shift during follow-up period was not significantly different among the groups (P=0.612. However, the changes in the HDD/VDD and PPW/VDD ratios were significantly greater in the disc suspect group and significantly smaller in the glaucoma group. Among the 42 eyes with an ONH/PPA change, 16 (38.1% were from the normal control group, 24 (57.1% were

  19. Lumbar spine intervertebral disc gene delivery: a pilot study in lewis rats.

    Science.gov (United States)

    Damle, Sheela R; Rawlins, Bernard A; Boachie-Adjei, Oheneba; Crystal, Ronald G; Hidaka, Chisa; Cunningham, Matthew E

    2013-02-01

    Basic research toward understanding and treating disc pathology in the spine has utilized numerous animal models, with delivery of small molecules, purified factors, and genes of interest. To date, gene delivery to the rat lumbar spine has only been described utilizing genetically programmed cells in a matrix which has required partial disc excision, and expected limitation of treatment diffusion into the disc. This study was designed to develop and describe a surgical technique for lumbar spine exposure and disc space preparation, and use of a matrix-free method for gene delivery. Naïve or genetically programmed isogeneic bone marrow stromal cells were surgically delivered to adolescent male Lewis rat lumbar discs, and utilizing quantitative biochemical and qualitative immunohistological assessments, the implanted cells were detected 3 days post-procedure. Statistically significant differences were noted for recovery of the β-galactosidase marker gene comparing delivery of naïve or labeled cells (10(5) cells per disc) from the site of implantation, and between delivery of 10(5) or 10(6) labeled cells per disc at the site of implantation and the adjacent vertebral body. Immunohistology confirmed that the β-galactosidase marker was detected in the adjacent vertebra bone in the zone of surgical implantation. The model requires further testing in larger cohorts and with biologically active genes of interest, but the observations from the pilot experiments are very encouraging that this will be a useful comparative model for basic spine research involving gene or cell delivery, or other locally delivered therapies to the intervertebral disc or adjacent vertebral bodies in rats.

  20. Implant planning on NobelClinician software‎ : incidence of bone density on the implants orientation for completely edentulous maxillae

    OpenAIRE

    Vankelst, Maëva

    2016-01-01

    The Purpose of this study wasto compare bone density in straight and tilted implants using the software NobelClinician on fifteen maxillary edentulous. For each patient, two schedules were created on NobelClinician: a first plan of 6 implants placed axially and a second plan where the last implant of each sector was tilted of 30 ° from the occlusal plane. The laying of the first four implants being common to both plans.The study was performed on DICOM files coming from the CBCT’s of 15 patien...

  1. Influence of patient position and implant material on the stress distribution in an artificial intervertebral disc of the lumbar vertebrae

    Directory of Open Access Journals (Sweden)

    Karpiński Robert

    2017-01-01

    Full Text Available The aim of this paper was to determine the effect of using cobalt and titanium-based alloys as implant materials for the lumbar vertebrae with an artificial intervertebral disc on the stress distribution. The lumbar vertebrae were chosen for the study because they carry considerably higher loads, especially while standing or sitting. Finite element method (FEM simulations were conducted for three standard loads reflecting three patient's positions: recumbent, standing and sitting. The FEM analysis was performed using the SolidWorks Simulation module. Artificial units containing a pair of vertebrae with a prosthesis between them were designed by the Solid Edge software, based on micro-computed tomography CT scans of the patient's spine. The implant model was designed with its shape based on the geometry of surrounding vertebrae, consisting of an upper pad, a bottom pad and an insert (intervertebral disc. Two implant material configurations were studied. One involved the use of titanium alloy for the upper and bottom pads, while in the other, these pads were made of cobalt alloy. In both cases, a polyethylene insert was used. The FEM results demonstrate that both material configurations meet the requirements for prosthesis design. In both material configurations, the maximum stresses in each prosthesis element are almost twice higher in a sitting posture than in a recumbent position.

  2. Tribological studies of ion-implanted steel constituents

    International Nuclear Information System (INIS)

    Wei, Ronghau.

    1990-01-01

    Tribological properties of ion-implanted ferrite and austenite were studied systematically using a unique oscillating pin-on-disc wear tester. Results show that nitrogen implantation at elevated temperatures to high doses dramatically improves the adhesive wear resistance of ferrite and the critical load at which the adhesive wear mechanism changes from mild to severe for austenite. The wear resistance of nitrogen-implanted ferrite is determined by the nitride formed. Extremely hard solid solutions of nitrogen develop on the implanted austenite surfaces and induce three orders of magnitude reductions in wear rates. The implantation conditions that should be used to produce deep, wear-resistant layers for both steels are discussed in detail. Oscillating pin-on-disc wear tests demonstrate that nitrogen does not diffuse during the wearing process although tests conducted using conventional fixed pin-on-disc test equipment could erroneously suggest this occurs. Taken together, the results show that high-dose-rate implantation at low energies yields very-high-quality implanted surfaces at low cost

  3. Biomaterials for intervertebral disc regeneration and repair.

    Science.gov (United States)

    Bowles, Robert D; Setton, Lori A

    2017-06-01

    The intervertebral disc contributes to motion, weight bearing, and flexibility of the spine, but is susceptible to damage and morphological changes that contribute to pathology with age and injury. Engineering strategies that rely upon synthetic materials or composite implants that do not interface with the biological components of the disc have not met with widespread use or desirable outcomes in the treatment of intervertebral disc pathology. Here we review bioengineering advances to treat disc disorders, using cell-supplemented materials, or acellular, biologically based materials, that provide opportunity for cell-material interactions and remodeling in the treatment of intervertebral disc disorders. While a field still in early development, bioengineering-based strategies employing novel biomaterials are emerging as promising alternatives for clinical treatment of intervertebral disc disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Material Science in Cervical Total Disc Replacement

    Science.gov (United States)

    Pham, Martin H.; Mehta, Vivek A.; Tuchman, Alexander; Hsieh, Patrick C.

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation. PMID:26523281

  5. Material Science in Cervical Total Disc Replacement.

    Science.gov (United States)

    Pham, Martin H; Mehta, Vivek A; Tuchman, Alexander; Hsieh, Patrick C

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  6. [Longterm results of cervical arthroplasty with disc prosthesis. A literature review].

    Science.gov (United States)

    Fransen, P; Schils, F

    2014-01-01

    Cervical arthroplasty has now been performed for over 10 years. Despite the large number of implanted artificial discs, the quality of the published studies is weak, and very few report a follow up exceeding two years. We reviewed the literature on cervical total disc replacement, focusing on publications reporting a follow-up of more than two years. The selection of patients, the type of implant and the surgical technique seem to influence greatly the quality of the clinical and radiological results. The occurrence of heterotopic ossifications around the implant seems to be the rule rather than the exception. Wear debris are likely to be observed in the vicinity of the prosthesis. Most long term studies also report a progressive decrease in the range of motion of the prosthesis, although without influence on the clinical evolution. It seems reasonable to say that cervical disc prosthesis is not inferior to discectomy and fusion, and that these implants allow a short term preservation of cervical mobility, but the efficacy in preventing adjacent segment disease or a favourable costleffectiveness ratio have yet to be demonstrated. A more widespread use of cervical disc prosthesis can only be suggested when these questions have been answered by long term follow-up studies.

  7. Cervical artificial disc extrusion after a paragliding accident

    OpenAIRE

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C.

    2017-01-01

    Background: Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. Case Description: ...

  8. Material Science in Cervical Total Disc Replacement

    Directory of Open Access Journals (Sweden)

    Martin H. Pham

    2015-01-01

    Full Text Available Current cervical total disc replacement (TDR designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti, and cobalt-chrome (CoCr. These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  9. Biomimetic hydrogels for biosensor implant biocompatibility: electrochemical characterization using micro-disc electrode arrays (MDEAs).

    Science.gov (United States)

    Justin, Gusphyl; Finley, Stephen; Abdur Rahman, Abdur Rub; Guiseppi-Elie, Anthony

    2009-02-01

    Our interest is in the development of engineered microdevices for continuous remote monitoring of intramuscular lactate, glucose, pH and temperature during post-traumatic hemorrhaging. Two important design considerations in the development of such devices for in vivo diagnostics are discussed; the utility of micro-disc electrode arrays (MDEAs) for electrochemical biosensing and the application of biomimetic, bioactive poly(HEMA)-based hydrogel composites for implant biocompatibility. A poly(HEMA)-based hydrogel membrane containing polyethylene glycol (PEG) was UV cross-linked with tetraethyleneglycol diacrylate following application to MDEAs (50 mum discs) and to 250 mum diameter gold electrodes within 8-well culture ware. Cyclic voltammetry (CV) of the MDEAs revealed a reduction in the apparent diffusion coefficient of ferrocenemonocarboxylic acid (FcCO(2)H), from 6.68 x 10(-5) to 6.74 x 10(-6) cm(2)/s for the uncoated and 6 mum thick hydrogel coated devices, respectively. Single frequency (4 kHz) temporal impedance measurements of the hydrogels in the 8-well culture ware showed a reversible 5% change in the absolute impedance of the hydrogels when exposed to a pH change between 6.1 to 7.2 and a 20% drop between pH 6.1 and 8.8.

  10. Efficacy of tilt training in patients with vasovagal syncope.

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Mazurek, Walentyna

    2006-06-01

    Besides pharmacological therapy and pacemaker implantation, tilt training is a promising method of treatment in patients with vasovagal syncope (VVS). Tilt training is usually offered to patients with malignant or recurrent VVS which impairs their quality of life and carries a risk of injury. To assess the efficacy of tilt training in patients with VVS. The study group consisted of 40 patients (29 females, 11 males, aged 36.6+/-14 years, range 18-57 years) who underwent tilt training using tilt table testing according to the Westminster protocol. The mean number of syncopal episodes prior to the initiation of tilt training was 6.5+/-4.9 (range 0-20); 3 patients had a history of very frequent faints. According to the VASIS classification, type I VVS (mixed) was diagnosed in 17 patients, type II (cardioinhibitory) in 22 subjects, and type III (vasodepressive) in one patient. Mean follow-up duration was 35.1+/-13.5 months. The control group, which did not undergo the tilt testing programme, consisted of 29 patients with VVS (25 females, 4 males, mean age 44.2+/-15.0 years) who had a mean of 3.3+/-3.2 (range 0-12) syncopal episodes in the past (p <0.05 vs study group); 6 of these patients had only pre-syncopal episodes. Type I VVS was diagnosed in 23 controls and type II VVS in 6 control subjects (syncope occurred during the passive phase of tilt testing in 7 subjects, whereas the remaining 22 fainted during NTG infusion). Of the patients from the study group, 3 underwent pacemaker implantation at the time of the initiation of tilt training. At the end of follow-up, 31 (77.5%) patients remained free from syncope recurrences, 5 had syncopal episodes during the initial phase of tilt training, whereas the remaining 4 continued to suffer from syncopal episodes. Out of 3 patients with presyncope, 2 had no syncope recurrences whereas 1 patient continued to have presyncopal attacks. Out of 3 patients with pacemakers, 1 reported activation of pacing in the interventional mode

  11. Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc

    International Nuclear Information System (INIS)

    Biederer, J.; Hutzelmann, A.; Heller, M.; Rama, B.

    1999-01-01

    Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with local symptoms can be evaluated with follow-up X-rays and functional imaging. (orig.) [de

  12. Cervical artificial disc extrusion after a paragliding accident.

    Science.gov (United States)

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C

    2017-01-01

    Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. A 33-year-old female who had undergone C4-C5 CAD implantation presented with neck pain and spasm after experiencing a paragliding accident. A 4 mm anterior protrusion of the CAD was seen on x-ray. She underwent removal of the CAD followed by anterior fusion. Other cases of CAD extrusion in the literature are discussed and the device's durability and testing are considered. Overall, CAD extrusion is a rare event. This case is likely the result of insufficient osseous integration. Patients undergoing cervical TDR should avoid high-risk activities to prevent trauma that could compromise the disc's placement, and future design/research should focus on how to enhance osseous integration at the interface while minimizing excessive heterotopic ossification.

  13. Spine imaging after lumbar disc replacement: pitfalls and current recommendations

    Directory of Open Access Journals (Sweden)

    Sandén Bengt

    2009-07-01

    Full Text Available Abstract Background Most lumbar artificial discs are still composed of stainless steel alloys, which prevents adequate postoperative diagnostic imaging of the operated region when using magnetic resonance imaging (MRI. Thus patients with postoperative radicular symptoms or claudication after stainless steel implants often require alternative diagnostic procedures. Methods Possible complications of lumbar total disc replacement (TDR are reviewed from the available literature and imaging recommendations given with regard to implant type. Two illustrative cases are presented in figures. Results Access-related complications, infections, implant wear, loosening or fracture, polyethylene inlay dislodgement, facet joint hypertrophy, central stenosis, and ankylosis of the operated segment can be visualised both in titanium and stainless steel implants, but require different imaging modalities due to magnetic artifacts in MRI. Conclusion Alternative radiographic procedures should be considered when evaluating patients following TDR. Postoperative complications following lumbar TDR including spinal stenosis causing radiculopathy and implant loosening can be visualised by myelography and radionucleotide techniques as an adjunct to plain film radiographs. Even in the presence of massive stainless steel TDR implants lumbar radicular stenosis and implant loosening can be visualised if myelography and radionuclide techniques are applied.

  14. Channeling effect for low energy ion implantation in Si

    International Nuclear Information System (INIS)

    Cho, K.; Allen, W.R.; Finstad, T.G.; Chu, W.K.; Liu, J.; Wortman, J.J.

    1985-01-01

    Ion implantation is one of the most important processes in semiconductor device fabrication. Due to the crystalline nature of Si, channeling of implanted ions occurs during this process. Modern devices become smaller and shallower and therefore require ion implantation at lower energies. The effect of channeling on ion implantation becomes a significant problem for low energy ion implantation. The critical angle for axial and planar channeling increases with decreasing energy. This corresponds to an increased probability for channeling with lowering of ion energy. The industry approach to avoid the channeling problem is to employ a tilt angle of 7 0 between the ion implantation direction and the surface normal. We approach the problem by mapping major crystalline axes and planes near the [100] surface normal. Our analysis indicates that a 7 0 tilt is not an optimum selection in channeling reduction. Tilt angles in the range 5 0 to 6 0 combined with 7 0 +- 0.5 0 rotation from the (100) plane are better selections for the reduction of the channeling effect. The range of suitable angles is a function of the implantation energy. Implantations of boron along well specified crystallographic directions have been carried out by careful alignment and the resulting boron profiles measured by SIMS. (orig.)

  15. Assessment of lumbar intervertebral disc glycosaminoglycan content by gadolinium-enhanced MRI before and after 21-days of head-down-tilt bedrest.

    Directory of Open Access Journals (Sweden)

    Timmo Koy

    Full Text Available During spaceflight, it has been shown that intervertebral discs (IVDs increase in height, causing elongation of the spine up to several centimeters. Astronauts frequently report dull lower back pain that is most likely of discogenic origin and may result from IVD expansion. It is unknown whether disc volume solely increases by water influx, or if the content of glycosaminoglycans also changes in microgravity. Aim of this pilot study was to investigate effects of the spaceflight analog of bedrest on the glycosaminoglycan content of human lumbar IVDs. Five healthy, non-smoking, male human subjects of European descent were immobilized in 6° head-down-tilt bedrest for 21 days. Subjects remained in bed 24 h a day with at least one shoulder on the mattress. Magnetic Resonance Imaging (MRI scans were taken according to the delayed gadolinium-enhanced magnetic resonance imaging (dGEMRIC protocol before and after bedrest. The outcome measures were T1 and ΔT1. Scans were performed before and after administration of the contrast agent Gd-DOTA, and differences between T1-values of both scans (ΔT1 were computed. ΔT1 is the longitudinal relaxation time in the tissue and inversely related to the glycosaminoglycan-content. For data analysis, IVDs L1/2 to L4/5 were semi-automatically segmented. Zones were defined and analyzed separately. Results show a highly significant decrease in ΔT1 (p<0.001 after bedrest in all IVDs, and in all areas of the IVDs. The ΔT1-decrease was most prominent in the nucleus pulposus and in L4/5, and was expressed slightly more in the posterior than anterior IVD. Unexpected negative ΔT1-values were found in Pfirrmann-grade 2-discs after bedrest. Significantly lower T1 before contrast agent application was found after bedrest compared to before bedrest. According to the dGEMRIC-literature, the decrease in ΔT1 may be interpreted as an increase in glycosaminoglycans in healthy IVDs during bedrest. This interpretation seems

  16. M6-C artificial disc placement.

    Science.gov (United States)

    Coric, Domagoj; Parish, John; Boltes, Margaret O

    2017-01-01

    There has been a steady evolution of cervical total disc replacement (TDR) devices over the last decade resulting in surgical technique that closely mimics anterior cervical discectomy and fusion as well as disc design that emphasizes quality of motion. The M6-C TDR device is a modern-generation artificial disc composed of titanium endplates with tri-keel fixation as well as a polyethylene weave with a polyurethane core. Although not yet approved by the FDA, M6-C has finished a pilot and pivotal US Investigational Device Exemption (IDE) study. The authors present the surgical technique for implantation of a 2-level M6-C cervical TDR device. The video can be found here: https://youtu.be/rFEAqINLRCo .

  17. Realization of a tilted reference wave for electron holography by means of a condenser biprism

    Energy Technology Data Exchange (ETDEWEB)

    Röder, Falk, E-mail: Falk.Roeder@tu-dresden.de [Triebenberg Labor, Institut für Strukturphysik, Technische Universität Dresden, D-01062 Dresden (Germany); CEMES-CNRS and Université de Toulouse, 29 rue Jeanne Marvig, F-31055 Toulouse (France); Houdellier, Florent; Denneulin, Thibaud; Snoeck, Etienne; Hÿtch, Martin [CEMES-CNRS and Université de Toulouse, 29 rue Jeanne Marvig, F-31055 Toulouse (France)

    2016-02-15

    As proposed recently, a tilted reference wave in off-axis electron holography is expected to be useful for aberration measurement and correction. Furthermore, in dark-field electron holography, it is considered to replace the reference wave, which is conventionally diffracted in an unstrained object area, by a well-defined object-independent reference wave. Here, we first realize a tilted reference wave by employing a biprism placed in the condenser system above three condenser lenses producing a relative tilt magnitude up to 20/nm at the object plane (300 kV). Paraxial ray-tracing predicts condenser settings for a parallel illumination at the object plane, where only one half of the round illumination disc is tilted relative to the optical axis without displacement. Holographic measurements verify the kink-like phase modulation of the incident beam and return the interference fringe contrast as a function of the relative tilt between both parts of the illumination. Contrast transfer theory including condenser aberrations and biprism instabilities was applied to explain the fringe contrast measurement. A first dark-field hologram with a tilted – object-free – reference wave was acquired and reconstructed. A new application for bright/dark-field imaging is presented.

  18. The effects of N+ implantation on the wear and friction of type 304 and 15-5 PH stainless steels

    International Nuclear Information System (INIS)

    Yost, F.G.; Picraux, S.T.; Follstaedt, D.M.; Pope, L.E.; Knapp, J.A.

    1983-01-01

    Ion implantation of N + into mechanically polished type 304 and 15-5 PH stainless steels was studied to determine its effect on dry wear and friction behavior. Implantation of 4.0 X 10 17 N + cm -2 at 50 keV yielded a depth profile with a peak concentration of about 45 at.% at a depth of 70 nm which dropped to about 10 at.% at 120 nm. Wear and friction were studied in an unlubricated pin-on-disc configuration using type 304 and 440C stainless steel pins. Both N + -implanted steels exhibited reduced wear at low loads but no significant reduction in the coefficient of friction was found. At the lowest normal load studied (12.3 gf), the average maximum wear depth of the implanted 15-5 PH stainless steel disc (about 0.1 μm) was reduced to approximately 10% of that for the corresponding unimplanted pin-on-disc pair after 1000 cycles. At normal loads of 50 gf or above (corresponding to hertzian stresses of 1160 MPa or higher) all beneficial effects were gone. Vacuum heat treatment at 923 K for 1.8 ks of an identically implanted type 304 stainless steel specimen eradicated the beneficial effects of the nitrogen implantation. The N + -implanted discs show similar reductions in wear to discs implanted with titanium and carbon, but the N + -implanted discs do not exhibit the reductions in the coefficient of friction seen with the discs implanted with titanium and carbon. (Auth.)

  19. Intervertebral disc (IVD): Structure, degeneration, repair and regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Whatley, Benjamin R.; Wen Xuejun, E-mail: xjwen@clemson.edu

    2012-02-01

    Low back pain affects a large portion of the population, resulting in high care costs for therapy and treatment. One primary cause of low back pain is the degeneration of the intervertebral disc (IVD) resulting in the compression of the spinal nerves and adjacent vertebrae. Exact causes of degeneration are unknown, but it is thought that natural aging, and both biological and genetic factors may play a significant role in the degenerative process. Conventional methods to alleviate low back pain include spinal fusion and artificial disc replacement. Traditional treatments through spinal fusion may eliminate pain yet do not restore disc function and lead to further degeneration of adjacent levels by altering disc biomechanics and natural kinematics. Recently, artificial IVD replacements have started to gain interest, with two IVD implants currently approved in the United States. Although these implants facilitate the preservation of motions and disc space height, they are unable to sustain compressive forces due to their lack of elasticity. In addition, the implants may produce wear debris that can cause osteolysis and other deleterious effects. As an alternative to these conventional approaches, tissue engineered IVD constructs offer the advantage of biointegration while preserving the essential attributes of natural motion and disc space restoration. There is a great need for the development of tissue engineered scaffolds that simulate the natural 3D morphology and microenvironment of the targeted tissue. Scaffolds should facilitate biological transport to satisfy nutrition and waste removal requirements within the IVD. The discrete tissue architectures of the nucleus pulposus (NP) and annulus fibrosus (AF) have posed great challenges to IVD tissue engineering. Current attempts have not been able to satisfy the biological functions and/or mechanical properties of native tissue. Therefore, these current scaffolds are far from satisfactory. This review highlights the

  20. Ion implantation in advanced planar and vertical devices

    International Nuclear Information System (INIS)

    Gossmann, Hans-Joachim L.

    2005-01-01

    The extent ('gate overlap') and slope ('abruptness') of the lateral junction are quickly replacing vertical junction depth as the most important physical junction metrics in advanced device architectures. This is in particular true for ultra-thin body devices, where the vertical junction is limited by a geometric constraint. The optimum gate overlap is quite small, or may even be negative, making a process without the need of high-tilt implantation feasible, even for dopant activation with negligible diffusion by flash annealing or laser thermal processing. Dopant activation by solid phase epitaxial regrowth might require high-tilt implants for a positive overlap. The use of such implants, however, is expected to lead to severe gate-poly and gate-oxide degradation. Scaling the 150 nm technology has drastically shrunk the overlap, accomplished by an equally aggressive reduction in thermal budget. For a 65 nm node device, a significant fraction of the overlap originates in the as-implanted dopant profile and the importance of diffusion is diminished. As a consequence small changes in the as-implanted profile are beginning to have a disproportionate impact on device characteristics. Small angular deviations of the incident beam from normal incidence, as seen by the wafer, lead to large changes in on-current. This can be alleviated significantly by a quad implant provided the tilt-angle is sufficiently large, in the order >5 deg.

  1. Histomorphometric and histologic evaluation of titanium-zirconium (aTiZr) implants with anodized surfaces.

    Science.gov (United States)

    Sharma, Ajay; McQuillan, A James; Shibata, Yo; Sharma, Lavanya A; Waddell, John Neil; Duncan, Warwick John

    2016-05-01

    The choice of implant surface has a significant influence on osseointegration. Modification of TiZr surface by anodization is reported to have the potential to modulate the osteoblast cell behaviour favouring more rapid bone formation. The aim of this study is to investigate the effect of anodizing the surface of TiZr discs with respect to osseointegration after four weeks implantation in sheep femurs. Titanium (Ti) and TiZr discs were anodized in an electrolyte containing DL-α-glycerophosphate and calcium acetate at 300 V. The surface characteristics were analyzed by scanning electron microscopy, electron dispersive spectroscopy, atomic force microscopy and goniometry. Forty implant discs with thickness of 1.5 and 10 mm diameter (10 of each-titanium, titanium-zirconium, anodized titanium and anodized titanium-zirconium) were placed in the femoral condyles of 10 sheep. Histomorphometric and histologic analysis were performed 4 weeks after implantation. The anodized implants displayed hydrophilic, porous, nano-to-micrometer scale roughened surfaces. Energy dispersive spectroscopy analysis revealed calcium and phosphorous incorporation into the surface of both titanium and titanium-zirconium after anodization. Histologically there was new bone apposition on all implanted discs, slightly more pronounced on anodised discs. The percentage bone-to-implant contact measurements of anodized implants were higher than machined/unmodified implants but there was no significant difference between the two groups with anodized surfaces (P > 0.05, n = 10). The present histomorphometric and histological findings confirm that surface modification of titanium-zirconium by anodization is similar to anodised titanium enhances early osseointegration compared to machined implant surfaces.

  2. Spine imaging after lumbar disc replacement: pitfalls and current recommendations

    OpenAIRE

    Robinson, Yohan; Sand?n, Bengt

    2009-01-01

    Abstract Background Most lumbar artificial discs are still composed of stainless steel alloys, which prevents adequate postoperative diagnostic imaging of the operated region when using magnetic resonance imaging (MRI). Thus patients with postoperative radicular symptoms or claudication after stainless steel implants often require alternative diagnostic procedures. Methods Possible complications of lumbar total disc replacement (TDR) are reviewed from the available literature and imaging reco...

  3. Effect of total lumbar disc replacement on lumbosacral lordosis.

    Science.gov (United States)

    Kasliwal, Manish K; Deutsch, Harel

    2012-10-01

    Original article : To study effect of lumbar disc replacement on lumbosacral lordosis. There has been a growing interest in total disc replacement (TDR) for back pain with the rising concern of adjacent segment degeneration. Lumbar fusion surgery has been shown to lead to decrease in lumbar lordosis, which may account for postfusion pain resulting in less acceptable clinical outcome after successful fusion. TDR has recently emerged as an alternative treatment for back pain. There have been very few studies reporting lumbar sagittal outcome after TDR. Retrospective study of radiographic data of 17 patients who underwent TDR for single level degenerative disc disease at the author's institution was carried out. Study included measurement of preoperative and postoperative segmental and global lumbar lordosis and angle of lordosis. Patients age varied from 19 to 54 (mean, 35) years. Follow-up ranged from 12 to 24 months. TDR was performed at L4-5 level in 3 patients and L5-S1 level in 14 patients. The average values for segmental lordosis, global lordosis, and angle of lordosis at the operated level before and after surgery were 17.3, 49.7, and 8.6 degrees and 21.6, 54, and 9.5 degrees, respectively. There was a trend toward significant (P=0.02) and near significant (P=0.057) increase in segmental and global lordosis, respectively after TDR. Although prosthesis increased angle of lordosis at the level implanted in majority of the patients, the difference in preoperative and postoperative angle of lordosis was not significant (P=0.438). In addition, there was no correlation between the angle of implant of chosen and postoperative angle of lordosis at the operated level. The effect of TDR on sagittal balance appears favorable with an increase in global and segmental lumbar lordosis after single level TDR for degenerative disc disease. The degree of postoperative angle of lordosis was not affected by the angle of implant chosen at the operated level and varied

  4. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Traumatic Migration of the Bryan Cervical Disc Arthroplasty.

    Science.gov (United States)

    Wagner, Scott C; Kang, Daniel G; Helgeson, Melvin D

    2016-02-01

    Study Design Case study. Objective To describe a case of dislodgment and migration of the Bryan Cervical Disc (Medtronic Sofamor Danek, Memphis, Tennessee, United States) arthroplasty more than 6 months after implantation secondary to low-energy trauma. Methods The inpatient, outpatient, and radiographic medical records of a patient with traumatic migration of the Bryan Cervical Disc arthroplasty were reviewed. The authors have no relevant disclosures to report. Results A 36-year-old man with chronic left upper extremity radiculopathy underwent uncomplicated Bryan Cervical Disc arthroplasty at C5-C6, with complete resolution of his symptoms. Approximately 6 months after his index procedure, he sustained low-energy trauma to the posterior cervical spine, after being struck by a book falling from a shelf. The injury forced his neck into flexion, and though he did not have recurrence of his radiculopathy symptoms, radiographs demonstrated anterior migration of the arthroplasty device. He underwent revision to anterior cervical diskectomy and fusion. Conclusions Although extremely rare, it is imperative that surgeons consider the potential for failure of osseous integration in patients undergoing cervical disk arthroplasty, even beyond 3 to 6 months postoperatively. This concern is especially relevant to press-fit or milled devices like the Bryan Cervical Disc arthroplasty, which lack direct fixation into adjacent vertebral bodies. We are considering modification of our postoperative protocol to improve protection of the device after implantation, even beyond 3 months postoperatively.

  6. A simple method to produce quasi-simultaneous multiple energy helium implantation

    International Nuclear Information System (INIS)

    Paszti, F.; Fried, M.; Manuaba, A.; Mezey, G.; Kotai, E.; Lohner, T.

    1982-11-01

    If a monoenergetic ion beam is bombarding a target through an absorber foil tilted continuously (i.e. its effective thickness changing continuously), the depth distribution of the implanted ions in the sample depends on the way the absorber is moving. The present paper describes a way of absorber tilting for obtaining a uniform depth distribution and its experimental verification in the case of MeV energy helium ions implanted into aluminium target. (author)

  7. Are Collapsed Cervical Discs Amenable to Total Disc Arthroplasty?: Analysis of Prospective Clinical Data With 2-Year Follow Up.

    Science.gov (United States)

    Patwardhan, Avinash G; Carandang, Gerard; Voronov, Leonard I; Havey, Robert M; Paul, Gary A; Lauryssen, Carl; Coric, Domagoj; Dimmig, Thomas; Musante, David

    2016-12-15

    Analysis of prospectively collected radiographic data. To investigate the influence of preoperative index-level range of motion (ROM) and disc height on postoperative ROM after cervical total disc arthroplasty (TDA) using compressible disc prostheses. Clinical studies demonstrate benefits of motion preservation over fusion; however, questions remain unanswered as to which preoperative factors have the ability to identify patients who are most likely to have good postoperative motion, which is the primary rationale for TDA. We analyzed prospectively collected data from a single-arm, multicenter study with 2-year follow up of 30 patients with 48 implanted levels. All received compressible cervical disc prostheses of 6 mm-height (M6C, Spinal Kinetics, Sunnyvale, CA). The influence of index-level preoperative disc height and ROM (each with two levels: below-median and above-median) on postoperative ROM was analyzed using 2 x 2 ANOVA. We further analyzed the radiographic outcomes of a subset of discs with preoperative height less than 3 mm, the so-called "collapsed" discs. Shorter (3.0 ± 0.4 mm) discs were significantly less mobile preoperatively than taller (4.4 ± 0.5 mm) discs (6.7° vs. 10.5°, P = 0.01). The postoperative ROM did not differ between the shorter and taller discs (5.6° vs. 5.0°, P = 0.63). Tall discs that were less mobile preoperatively had significantly smaller postoperative ROM than short discs with above-median preoperative mobility (P < 0.05). The "collapsed discs" (n = 8) were less mobile preoperatively compared with all discs combined (5.1° vs. 8.6°, P < 0.01). These discs were distracted to more than two times the preoperative height, from 2.6 to 5.7 mm, and had significantly greater postoperative ROM than all discs combined (7.6° vs. 5.3°, P < 0.05). We observed a significant interaction between preoperative index-level disc height and ROM in influencing postoperative ROM. Although limited by small sample

  8. Antimicrobial effect of chlorhexidine on Aggregatibacter actinomycetemcomitans biofilms associated with peri-implantitis

    Directory of Open Access Journals (Sweden)

    Zeinab Kadkhoda

    2016-08-01

    Full Text Available Background. This study aimed to assessthe antimicrobial effect of chlorhexidine (CHX on Aggregatibacter actinomyce-temcomitans biofilms isolated from subgingival plaque of peri-implantitis lesions. Methods. Thirteen patients requiring peri-implantitis treatment were consecutively selected and their subgingival biofilm was collected by inserting fine sterile paper points into peri-implant pockets for 15 seconds. A. actinomycetemcomitans was isolated from the subgingival biofilm and cultured. In this study, the standard strain of A. actinomycetemcomitans served as the positive control group and a blank disc impregnated with water served as the negative control; 0.1 mL of the bacterial suspension was cultured on specific culture medium and blank discs (6 mm in diameter impregnated with 0.2%CHX mouthrinse (Behsa Pharmaceutical Co. and negative control discs were placed on two sides of the bacterial culture plate. The size of growth inhibition zone was measured by a blinded independent observer in millimetres. Results. According to the results of disc diffusion test, the mean diameter of growth inhibition zone of A. actinomycetem-comitans around discs impregnated with CHX was larger in both standard (positive control and biofilm samples of A. acti-nomycetemcomitans compared to the negative control group (blank disc (P<0.001. Conclusion. Use of0.2% CHX mouthwash had antibacterial effects on A. actinomycetemcomitans species isolated from peri-implantitis sites.

  9. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis.

    Science.gov (United States)

    Fazi, Giovanni; Tellini, Simone; Vangi, Dario; Branchi, Roberto

    2011-01-01

    The distribution of stresses in bone, implants, and prosthesis were analyzed via three-dimensional finite element modeling in different implant configurations for a fixed implant-supported prosthesis in an edentulous mandible. A finite element model was created with data obtained from computed tomographic scans of a human mandible. Anisotropic characteristics for cortical and cancellous bone were incorporated into the model. Six different configurations of intraforaminal implants were tested, with the number of implants varying from three to five and the distal implants inserted either parallel to the other implants or tilted distally by 17 or 34 degrees. A prosthetic structure connecting the implants was designed, with 20-mm posterior cantilevers for the parallel implant configurations, and a load of 200 N was applied to the distal portion of the cantilevers. Stresses were measured at the level of the implant, the prosthetic structure, and the bone. Bone-level stresses were analyzed at the implant-bone interface, at the external cortical bone surface, distal to the terminal implant, and in the cancellous bone along the implant body. A three-parallel-implant configuration resulted in higher stress in the implant and bone than configurations with four or five parallel implants. Configurations with the distal implants tilted resulted in a more favorable stress distribution at all levels. In parallel-implant configurations for fixed implant-supported mandibular prostheses, four and five implants resulted in similar stress distribution in the bone, framework, and implants. A distribution of four implants with the distal implants tilted 34 degrees (ie, the "All-on-Four" configuration) resulted in a favorable reduction of stresses in the bone, framework, and implants.

  10. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

    Science.gov (United States)

    Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V

    1992-02-01

    From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and

  11. Tribological effects of oxygen ion implantation into stainless steel

    International Nuclear Information System (INIS)

    Evans, P.J.; Vilaithong, T.; Yu, L.D.; Monteiro, O.R.; Yu, K.M.; Brown, I.G.

    2000-01-01

    The formation of sub-surface oxide layers by hybrid metal-gas co-implantation into steel and other metals can improve their tribological properties. In this report, we compare the wear and friction performance of previously studied Al + O hybrid implants with that produced by single species oxygen ion (O + ) implantation under similar conditions. The substrates were AISI 304L stainless steel discs polished to a final mirror finish using 1 μm diamond paste, and the ion implantation was done using a conventional swept-beam technique at ion energies of 70 or 140 keV and doses of up to 1x10 17 cm -2 . The wear and friction behaviour of the implanted and unimplanted material was measured with a pin-on-disc tribometer. Here we describe the experimental procedure and results, and discuss the improvement relative to that achieved with surface layers modified by metal-gas co-implantation

  12. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification

    Directory of Open Access Journals (Sweden)

    Hamed A. Hamed

    2018-02-01

    Full Text Available AIM: This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS: Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05. RESULTS: Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. CONCLUSION: It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  13. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification.

    Science.gov (United States)

    Hamed, Hamed A; Marzook, Hamdy A; Ghoneem, Nahed E; El-Anwar, Mohamed I

    2018-02-15

    This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  14. Percutaneous treatment of cervical and lumbar herniated disc

    Energy Technology Data Exchange (ETDEWEB)

    Kelekis, A., E-mail: akelekis@med.uoa.gr; Filippiadis, D.K., E-mail: dfilippiadis@yahoo.gr

    2015-05-15

    Therapeutic armamentarium for symptomatic intervertebral disc herniation includes conservative therapy, epidural infiltrations (interlaminar or trans-foraminal), percutaneous therapeutic techniques and surgical options. Percutaneous, therapeutic techniques are imaging-guided, minimally invasive treatments for intervertebral disc herniation which can be performed as outpatient procedures. They can be classified in 4 main categories: mechanical, thermal, chemical decompression and biomaterials implantation. Strict sterility measures are a prerequisite and should include extensive local sterility and antibiotic prophylaxis. Indications include the presence of a symptomatic, small to medium sized contained intervertebral disc herniation non-responding to a 4–6 weeks course of conservative therapy. Contraindications include sequestration, infection, segmental instability (spondylolisthesis), uncorrected coagulopathy or a patient unwilling to provide informed consent. Decompression techniques are feasible and reproducible, efficient (75–94% success rate) and safe (>0.5% mean complications rate) therapies for the treatment of symptomatic intervertebral disc herniation. Percutaneous, imaging guided, intervertebral disc therapeutic techniques can be proposed either as an initial treatment or as an attractive alternative prior to surgery for the therapy of symptomatic herniation in both cervical and lumbar spine. This article will describe the mechanism of action for different therapeutic techniques applied to intervertebral discs of cervical and lumbar spine, summarize the data concerning safety and effectiveness of these treatments, and provide a rational approach for the therapy of symptomatic intervertebral disc herniation in cervical and lumbar spine.

  15. Percutaneous treatment of cervical and lumbar herniated disc

    International Nuclear Information System (INIS)

    Kelekis, A.; Filippiadis, D.K.

    2015-01-01

    Therapeutic armamentarium for symptomatic intervertebral disc herniation includes conservative therapy, epidural infiltrations (interlaminar or trans-foraminal), percutaneous therapeutic techniques and surgical options. Percutaneous, therapeutic techniques are imaging-guided, minimally invasive treatments for intervertebral disc herniation which can be performed as outpatient procedures. They can be classified in 4 main categories: mechanical, thermal, chemical decompression and biomaterials implantation. Strict sterility measures are a prerequisite and should include extensive local sterility and antibiotic prophylaxis. Indications include the presence of a symptomatic, small to medium sized contained intervertebral disc herniation non-responding to a 4–6 weeks course of conservative therapy. Contraindications include sequestration, infection, segmental instability (spondylolisthesis), uncorrected coagulopathy or a patient unwilling to provide informed consent. Decompression techniques are feasible and reproducible, efficient (75–94% success rate) and safe (>0.5% mean complications rate) therapies for the treatment of symptomatic intervertebral disc herniation. Percutaneous, imaging guided, intervertebral disc therapeutic techniques can be proposed either as an initial treatment or as an attractive alternative prior to surgery for the therapy of symptomatic herniation in both cervical and lumbar spine. This article will describe the mechanism of action for different therapeutic techniques applied to intervertebral discs of cervical and lumbar spine, summarize the data concerning safety and effectiveness of these treatments, and provide a rational approach for the therapy of symptomatic intervertebral disc herniation in cervical and lumbar spine

  16. Effects of annulus defects and implantation of poly(lactic-co-glycolic acid) (PLGA)/fibrin gel scaffolds on nerves ingrowth in a rabbit model of annular injury disc degeneration.

    Science.gov (United States)

    Xin, Long; Xu, Weixing; Yu, Leijun; Fan, Shunwu; Wang, Wei; Yu, Fang; Wang, Zhenbin

    2017-05-12

    Growth of nerve fibers has been shown to occur in a rabbit model of intravertebral disc degeneration (IVD) induced by needle puncture. As nerve growth may underlie the process of chronic pain in humans affected by disc degeneration, we sought to investigate the factors underlying nerve ingrowth in a minimally invasive annulotomy rabbit model of IVD by comparing the effects of empty disc defects with those of defects filled with poly(lactic-co-glycolic acid)/fibrin gel (PLGA) plugs. New Zealand white rabbits (n = 24) received annular injuries at three lumbar levels (L3/4, L4/5, and L5/6). The discs were randomly assigned to four groups: (a) annular defect (1.8-mm diameter; 4-mm depth) by mini-trephine, (b) annular defect implanted with a PLGA scaffold containing a fibrin gel, (c) annular puncture by a 16G needle (5-mm depth), and (d) uninjured L2/3 disc (control). Disc degeneration was evaluated by radiography, MRI, histology, real-time PCR, and analysis of proteoglycan (PG) content. Nerve ingrowth into the discs was assessed by immunostaining with the nerve marker protein gene product 9.5. Injured discs showed a progressive disc space narrowing with significant disc degeneration and proteoglycan loss, as confirmed by imaging results, molecular and compositional analysis, and histological examinations. In 16G punctured discs, nerve ingrowth was observed on the surface of scar tissue. In annular defects, nerve fibers were found to be distributed along small fissures within the fibrocartilaginous-like tissue that filled the AF. In discs filled with PLGA/ fibrin gel, more nerve fibers were observed growing deeper into the inner AF along the open annular track.  In addition, innervations scores showed significantly higher than those of punctured discs and empty defects. A limited vascular proliferation was found in the injured sites and regenerated tissues. Nerve ingrowth was significantly higher in PLGA/fibrin-filled discs than in empty defects. Possible

  17. Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography

    International Nuclear Information System (INIS)

    Luckow, Marlen; Deyhle, Hans; Beckmann, Felix; Dagassan-Berndt, Dorothea; Müller, Bert

    2011-01-01

    Objective: The image quality in cone-beam computed tomography (CBCT) should be improved tilting the mandible that contains two dental titanium implants, within the relevant range of motion. Materials and methods: Using the mandible of a five-month-old pig, CBCT was performed varying the accelerating voltage, beam current, the starting rotation angle of the mandible in the source-detector plane and the tilt angles of the jaw with respect to the source-detector plane. The different datasets were automatically registered with respect to micro CT data to extract the common volume and the deviance to the pre-defined standard that characterizes the image quality. Results: The variations of the accelerating voltage, beam current and the rotation within the source-detection plane provided the expected quantitative behavior indicating the appropriate choice of the imaging quality factor. The tilting of the porcine mandible by about 14° improves the image quality by almost a factor of two. Conclusions: The tilting of the mandible with two dental implants can be used to significantly reduce the artifacts of the strongly X-ray absorbing materials in the CBCT images. The comparison of 14° jaw tilting with respect to the currently recommended arrangement in plane with the teeth demonstrates that the applied exposure time and the related dose can be reduced by a factor of four without decreasing the image quality.

  18. Disc degeneration: current surgical options

    Directory of Open Access Journals (Sweden)

    C Schizas

    2010-10-01

    Full Text Available Chronic low back pain attributed to lumbar disc degeneration poses a serious challenge to physicians. Surgery may be indicated in selected cases following failure of appropriate conservative treatment. For decades, the only surgical option has been spinal fusion, but its results have been inconsistent. Some prospective trials show superiority over usual conservative measures while others fail to demonstrate its advantages. In an effort to improve results of fusion and to decrease the incidence of adjacent segment degeneration, total disc replacement techniques have been introduced and studied extensively. Short-term results have shown superiority over some fusion techniques. Mid-term results however tend to show that this approach yields results equivalent to those of spinal fusion. Nucleus replacement has gained some popularity initially, but evidence on its efficacy is scarce. Dynamic stabilisation, a technique involving less rigid implants than in spinal fusion and performed without the need for bone grafting, represents another surgical option. Evidence again is lacking on its superiority over other surgical strategies and conservative measures. Insertion of interspinous devices posteriorly, aiming at redistributing loads and relieving pain, has been used as an adjunct to disc removal surgery for disc herniation. To date however, there is no clear evidence on their efficacy. Minimally invasive intradiscal thermocoagulation techniques have also been tried, but evidence of their effectiveness is questioned. Surgery using novel biological solutions may be the future of discogenic pain treatment. Collaboration between clinicians and basic scientists in this multidisciplinary field will undoubtedly shape the future of treating symptomatic disc degeneration.

  19. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    Science.gov (United States)

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for

  20. Intervertebral Fusion with Mobile Microendoscopic Discectomy for Lumbar Degenerative Disc Disease.

    Science.gov (United States)

    Xu, Bao-Shan; Liu, Yue; Xu, Hai-Wei; Yang, Qiang; Ma, Xin-Long; Hu, Yong-Cheng

    2016-05-01

    The aim of this article is to introduce a technique for lumbar intervertebral fusion that incorporates mobile microendoscopic discectomy (MMED) for lumbar degenerative disc disease. Minimally invasive transforaminal lumbar interbody fusion is frequently performed to treat degenerative diseases of the lumbar spine; however, the scope of such surgery and vision is limited by what the naked eye can see through the expanding channel system. To expand the visual scope and reduce trauma, we perform lumbar intervertebral fusion with the aid of a MMED system that provides a wide field through freely tilting the surgical instrument and canals. We believe that this technique is a good option for treating lumbar degenerative disc disease that requires lumbar intervertebral fusion. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  1. Monte Carlo simulation of boron-ion implantation into single-crystal silicon

    International Nuclear Information System (INIS)

    Klein, K.M.

    1991-01-01

    A physically based Monte Carlo boron implantation model developed comprehends previously neglected but important implant parameters such as native oxide layers, wafer temperature, beam divergence, tilt angle, rotation (twist) angle, and dose, in addition to energy. This model uses as its foundation the MARLOWE Monte Carlo simulation code developed at Oak Ridge National Laboratory for the analysis of radiation effects in materials. This code was carefully adapted for the simulation of ion implantation, and a number of significant improvements have been made, including the addition of atomic pair specific interatomic potentials, the implementation of a newly developed local electron concentration dependent electronic stopping model, and the implementation of a newly developed cumulative damage model. This improved version of the code, known as UT-MARLOWE, allows boron implantation profiles to be accurately predicted as a function of energy, tilt angle, rotation angle, and dose. This code has also been used in the development and implementation of an accurate and efficient two-dimensional boron implantation model

  2. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  3. Orbital alignment of circumbinary planets that form in misaligned circumbinary discs: the case of Kepler-413b

    Science.gov (United States)

    Pierens, A.; Nelson, R. P.

    2018-06-01

    Although most of the circumbinary planets detected by the Kepler spacecraft are on orbits that are closely aligned with the binary orbital plane, the systems Kepler-413 and Kepler-453 exhibit small misalignments of ˜2.5°. One possibility is that these planets formed in a circumbinary disc whose midplane was inclined relative to the binary orbital plane. Such a configuration is expected to lead to a warped and twisted disc, and our aim is to examine the inclination evolution of planets embedded in these discs. We employed 3D hydrodynamical simulations that examine the disc response to the presence of a modestly inclined binary with parameters that match the Kepler-413 system, as a function of disc parameters and binary inclinations. The discs all develop slowly varying warps, and generally display very small amounts of twist. Very slow solid body precession occurs because a large outer disc radius is adopted. Simulations of planets embedded in these discs resulted in the planet aligning with the binary orbit plane for disc masses close to the minimum mass solar nebular, such that nodal precession of the planet was controlled by the binary. For higher disc masses, the planet maintains near coplanarity with the local disc midplane. Our results suggest that circumbinary planets born in tilted circumbinary discs should align with the binary orbit plane as the disc ages and loses mass, even if the circumbinary disc remains misaligned from the binary orbit. This result has important implications for understanding the origins of the known circumbinary planets.

  4. Dynamic of charged planar geometry in tilted and non-tilted frames

    Energy Technology Data Exchange (ETDEWEB)

    Sharif, M., E-mail: msharif.math@pu.edu.pk; Zaeem Ul Haq Bhatti, M., E-mail: mzaeem.math@pu.edu.pk [University of the Punjab, Department of Mathematics (Pakistan)

    2015-05-15

    We investigate the dynamics of charged planar symmetry with an anisotropic matter field subject to a radially moving observer called a tilted observer. The Einstein-Maxwell field equations are used to obtain a relation between non-tilted and tilted frames and between kinematical and dynamical quantities. Using the Taub mass formalism and conservation laws, two evolution equations are developed to analyze the inhomogeneities in the tilted congruence. It is found that the radial velocity (due to the tilted observer) and the electric charge have a crucial effect on the inhomogeneity factor. Finally, we discuss the stability in the non-tilted frame in the pure diffusion case and examine the effects of the electromagnetic field.

  5. CT patellar cortex tilt angle: A radiological method to measure patellar tilt

    International Nuclear Information System (INIS)

    Mirza Toluei, F.; Afshar, A.; Salarilak, S.; Sina, A.

    2005-01-01

    Background/Objectives: the role of patellar tilt in the anterior knee pain is indisputable. Traditionally. the lateral patello-femoral angle of Laurin has been defined in both the axial view and CT images for measuring the tilt of patella. We present a new angle. which is independent of the morphology of patella and directly relates to clinical assessment of the tilt. which is appreciated from palpation of the edges of the patella. Patients and Methods: 38 patients with anterior knee pain and forty normal control subjects were examined using CT scan of patello-femoral joint in 15 degrees of knee flexion. The amount of lateral patellar tilt was quantitatively assessed using the lateral patello-femoral angle, as described by Laurin et al, and the newly defined patellar cortex tilt angle. This angle is subtended by the line drawn along the posterior femoral condyles and the one parallel to the subchondral bone of patellar cortex. The fifteen-degree tilt was taken as normal cut-off point for patellar cortex tilt angle in the control group. Results: in patients, the average tilt of patella. using the patellar cortex tilt angle was 15.26 versus 7.05 in the control group. Using Student's t test, the difference between the two means was significant (P<0.001). The sensitivity and specificity of patellar cortex tilt angle were 40 and 90 percent, respectively There was a moderate agreement between our presented test and the lateral tilt angle test (kappa=0.40. P<0.001). Conclusion: our results indicate that patellar tilt can also be detected using patellar cortex tilt angle. We need more specific studies ta determine the validity of the test

  6. Dippers and dusty disc edges: new diagnostics and comparison to model predictions

    Science.gov (United States)

    Bodman, Eva H. L.; Quillen, Alice C.; Ansdell, Megan; Hippke, Michael; Boyajian, Tabetha S.; Mamajek, Eric E.; Blackman, Eric G.; Rizzuto, Aaron; Kastner, Joel H.

    2017-09-01

    We revisit the nature of large dips in flux from extinction by dusty circumstellar material that is observed by Kepler for many young stars in the Upper Sco and ρ Oph star formation regions. These young, low-mass 'dipper' stars are known to have low accretion rates and primarily host moderately evolved dusty circumstellar discs. Young low-mass stars often exhibit rotating starspots that cause quasi-periodic photometric variations. We found no evidence for periods associated with the dips that are different from the starspot rotation period in spectrograms constructed from the light curves. The material causing the dips in most of these light curves must be approximately corotating with the star. We find that disc temperatures computed at the disc corotation radius are cool enough that dust should not sublime. Crude estimates for stellar magnetic field strengths and accretion rates are consistent with magnetospheric truncation near the corotation radius. Magnetospheric truncation models can explain why the dips are associated with material near corotation and how dusty material is lifted out of the mid-plane to obscure the star that would account for the large fraction of young low-mass stars that are dippers. We propose that variations in disc orientation angle, stellar magnetic field dipole tilt axis and disc accretion rate are underlying parameters accounting for differences in the dipper light curves.

  7. Tilt testing results are influenced by tilt protocol.

    Science.gov (United States)

    Zyśko, Dorota; Fedorowski, Artur; Nilsson, David; Rudnicki, Jerzy; Gajek, Jacek; Melander, Olle; Sutton, Richard

    2016-07-01

    It is unknown how the return to supine position influences duration of loss of consciousness (LOC) and cardioinhibition during tilt test. Retrospective analysis of two datasets containing records of patients who underwent tilt testing for unexplained syncope in two centres was performed. Patients, totalling 1232, were included in the study: 262 in a Swedish centre and 970 patients in a Polish centre. In Sweden, tilt table with tilt-down time (TDT) of 18 s was used (Group II). In Poland, two different tilt tables were used, one of them with TDT of 10 s (Group I, n = 325), and the other with TDT of 47 s (Group III, n = 645). Cardioinhibitory reflex occurred most frequently in Group III, whereas number of pauses >3 s, frequency of very long asystole ≥30 s, and the total duration of pauses >3 s demonstrated a trend to increase from Group I to III. Duration of LOC in Groups II and III was significantly longer compared with Group I (32.0 and 33.7 s vs. 16.4 s). In the multivariate-adjusted regression model, cardioinhibitory reflex was predicted by tilt-table model (odds ratio per model with increasing TDT: 1.40; 95% confidence interval, 1.19-1.64; P < 0.0001), whereas LOC duration was longer with increasing TDT (P < 0.0001) and age (P < 0.0001). Longer TDT during induced vasovagal syncope increases the prevalence of cardioinhibitory reflex and prolongs the duration of LOC. Tilt-down time does not affect asystolic pause duration but delay may lead to occurrence of multiple pauses, higher frequency of very long asystole, and longer total asystole duration. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  8. Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

    Science.gov (United States)

    MacBarb, Regina F; Lindsey, Derek P; Bahney, Chelsea S; Woods, Shane A; Wolfe, Mark L; Yerby, Scott A

    2017-01-01

    An aging society and concomitant rise in the incidence of impaired bone health have led to the need for advanced osteoconductive spinal implant surfaces that promote greater biological fixation ( e.g. for interbody fusion cages, sacroiliac joint fusion implants, and artificial disc replacements). Additive manufacturing, i.e. 3D-printing, may improve bone integration by generating biomimetic spinal implant surfaces that mimic bone morphology. Such surfaces may foster an enhanced cellular response compared to traditional implant surfacing processes. This study investigated the response of human osteoblasts to additive manufactured (AM) trabecular-like titanium implant surfaces compared to traditionally machined base material with titanium plasma spray (TPS) coated surfaces, with and without a nanocrystalline hydroxyapatite (HA) coating. For TPS-coated discs, wrought Ti6Al4V ELI was machined and TPS-coating was applied. For AM discs, Ti6Al4V ELI powder was 3D-printed to form a solid base and trabecular-like porous surface. The HA-coating was applied via a precipitation dip-spin method. Surface porosity, pore size, thickness, and hydrophilicity were characterized. Initial cell attachment, proliferation, alkaline phosphatase (ALP) activity, and calcium production of hFOB cells ( n =5 per group) were measured. Cells on AM discs exhibited expedited proliferative activity. While there were no differences in mean ALP expression and calcium production between TPS and AM discs, calcium production on the AM discs trended 48% higher than on TPS discs ( p =0.07). Overall, HA-coating did not further enhance results compared to uncoated TPS and AM discs. Results demonstrate that additive manufacturing allows for controlled trabecular-like surfaces that promote earlier cell proliferation and trends toward higher calcium production than TPS coating. Results further showed that nanocrystalline HA may not provide an advantage on porous titanium surfaces. Additive manufactured porous

  9. Hybrid testing of lumbar CHARITE discs versus fusions.

    Science.gov (United States)

    Panjabi, Manohar; Malcolmson, George; Teng, Edward; Tominaga, Yasuhiro; Henderson, Gweneth; Serhan, Hassan

    2007-04-20

    An in vitro human cadaveric biomechanical study. To quantify effects on operated and other levels, including adjacent levels, due to CHARITE disc implantations versus simulated fusions, using follower load and the new hybrid test method in flexion-extension and bilateral torsion. Spinal fusion has been associated with long-term accelerated degeneration at adjacent levels. As opposed to the fusion, artificial discs are designed to preserve motion and diminish the adjacent-level effects. Five fresh human cadaveric lumbar specimens (T12-S1) underwent multidirectional testing in flexion-extension and bilateral torsion with 400 N follower load. Intact specimen total ranges of motion were determined with +/-10 Nm unconstrained pure moments. The intact range of motion was used as input for the hybrid tests of 5 constructs: 1) CHARITE disc at L5-S1; 2) fusion at L5-S1; 3) CHARITE discs at L4-L5 and L5-S1; 4) CHARITE disc at L4-L5 and fusion at L5-S1; and 5) 2-level fusion at L4-L5-S1. Using repeated-measures single factor analysis of variance and Bonferroni statistical tests (P < 0.05), intervertebral motion redistribution of each construct was compared with the intact. In flexion-extension, 1-level CHARITE disc preserved motion at the operated and other levels, while 2-level CHARITE showed some amount of other-level effects. In contrast, 1- and 2-level fusions increased other-level motions (average, 21.0% and 61.9%, respectively). In torsion, both 1- and 2-level discs preserved motions at all levels. The 2-level simulated fusion increased motions at proximal levels (22.9%), while the 1-level fusion produced no significant changes. In general, CHARITE discs preserved operated- and other-level motions. Fusion simulations affected motion redistribution at other levels, including adjacent levels.

  10. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  11. 3D-printing zirconia implants; a dream or a reality? An in-vitro study evaluating the dimensional accuracy, surface topography and mechanical properties of printed zirconia implant and discs.

    Science.gov (United States)

    Osman, Reham B; van der Veen, Albert J; Huiberts, Dennis; Wismeijer, Daniel; Alharbi, Nawal

    2017-11-01

    The aim of this study was to evaluate the dimensional accuracy, surface topography of a custom designed, 3D-printed zirconia dental implant and the mechanical properties of printed zirconia discs. A custom designed implant was 3D-printed in zirconia using digital light processing technique (DLP). The dimensional accuracy was assessed using the digital-subtraction technique. The mechanical properties were evaluated using biaxial flexure strength test. Three different build angles were adopted to print the specimens for the mechanical test; 0°(Vertical), 45° (Oblique) and 90°(Horizontal) angles. The surface topography, crystallographic phase structure and surface roughness were evaluated using scanning electron microscopy analysis (SEM), X-ray diffractometer and confocal microscopy respectively. The printed implant was dimensionally accurate with a root mean square (RMSE) value of 0.1mm. The Weibull analysis revealed a statistically significant higher characteristic strength (1006.6MPa) of 0° printed specimens compared to the other two groups and no significant difference between 45° (892.2MPa) and 90° (866.7MPa) build angles. SEM analysis revealed cracks, micro-porosities and interconnected pores ranging in size from 196nm to 3.3µm. The mean Ra (arithmetic mean roughness) value of 1.59µm (±0.41) and Rq (root mean squared roughness) value of 1.94µm (±0.47) was found. A crystallographic phase of primarily tetragonal zirconia typical of sintered Yttria tetragonal stabilized zirconia (Y-TZP) was detected. DLP prove to be efficient for printing customized zirconia dental implants with sufficient dimensional accuracy. The mechanical properties showed flexure strength close to those of conventionally produced ceramics. Optimization of the 3D-printing process parameters is still needed to improve the microstructure of the printed objects. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effects of ion-implanted C on the microstructure and surface mechanical properties of Fe alloys implanted with Ti

    International Nuclear Information System (INIS)

    Follstaedt, D.M.; Knapp, J.A.; Pope, L.E.; Yost, F.G.; Picraux, S.T.

    1984-01-01

    The microstructural and tribological effects of ion implanting C into Ti-implanted, Fe-based alloys are examined and compared to the influence of C introduced by vacuum carburization during Ti implantation alone. The amorphous surface alloy formed by Ti implantation of pure Fe increases in thickness when additional C is implanted at depths containing Ti but beyond the range of carburization. Pin-on-disc tests of 15-5 PH stainless steel show that implantation of both Ti and C reduces friction significantly under conditions where no reduction is obtained by Ti implantation alone; wear depths are also less when C is implanted. All available experimental results can be accounted for by consideration of the thickness and Ti concentration of the amorphous Fe-Ti-C alloy. The thicker amorphous layer on samples implanted with additional C extends tribological benefits to more severe wear regimes

  13. Wear properties of metal ion implanted 4140 steel

    International Nuclear Information System (INIS)

    Evans, P.J.; Paoloni, F.J.

    1994-01-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10 16 ionscm -2 were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  14. Optical coherence tomography detection of characteristic retinal nerve fiber layer thinning in nasal hypoplasia of the optic disc.

    Science.gov (United States)

    Haruta, M; Kodama, R; Yamakawa, R

    2017-12-01

    PurposeTo determine the clinical usefulness of optical coherence tomography (OCT) for detecting thinning of the retinal nerve fiber layer (RNFL) in eyes with nasal hypoplasia of the optic discs (NHOD).Patients and methodsThe medical records of five patients (eight eyes) with NHOD were reviewed. The ratio of the disc-macula distance to the disc diameter (DM/DD) and the disc ovality ratio of the minimal to maximal DD were assessed using fundus photographs. The RNFL thicknesses of the temporal, superior, nasal, and inferior quadrants were evaluated using OCT quadrant maps.ResultsAll eight eyes had temporal visual field defects that respected the vertical meridians that needed to be differentiated from those related to chiasmal compression. The mean DM/DD ratio was 3.1 and the mean disc ovality ratio was 0.81. The mean RNFL thicknesses of the temporal, superior, nasal, and inferior quadrants were 90.3, 103.1, 34.8, and 112.8 microns, respectively.ConclusionSmall optic discs and tilted discs might be associated with NHOD. Measurement of the RNFL thickness around the optic disc using OCT scans clearly visualized the characteristic RNFL thinning of the nasal quadrants corresponding to the temporal sector visual field defects in eyes with NHOD. OCT confirmed the presence of NHOD and might differentiate eyes with NHOD from those with chiasmal compression.

  15. Disc defect classification for optical disc drives

    NARCIS (Netherlands)

    Helvoirt, van J.; Leenknegt, G.A.L.; Steinbuch, M.; Goossens, H.J.

    2005-01-01

    Optical disc drives are subject to various disturbances and faults. A special type of fault is the so-called disc defect. In this paper we present an approach for disc defect classification. It is based on hierarchical clustering of measured signals that are affected by disc defects. The

  16. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    Science.gov (United States)

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  17. Wear properties of metal ion implanted 4140 steel

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J. (Applications of Nuclear Physics, Ansto, Private Mail Bag 1, Menai, NSW 2234 (Australia)); Paoloni, F.J. (Department of Electrical and Computer Engineering, University of Wollongong, GPO Box 1144, Wollongong, NSW 2500 (Australia))

    1994-07-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10[sup 16]ionscm[sup -2] were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  18. Segmental translation after lumbar total disc replacement using Prodisc-L®: associated factors and relation to facet arthrosis.

    Science.gov (United States)

    Shin, Myung H; Ryu, Kyeong S; Rathi, Nitesh K; Park, Chun K

    2017-02-01

    Segmental translation after lumbar total disc replacement (TDR) with ProDisc-L® prosthesis frequently observed radiographic findings during follow-up period. However its precise pathomechanism and relation with facet arthrosis have not been investigated yet. This study was performed to evaluate possible factors that affect postoperative segmental translation and to identify its relation with facet joint degeneration after lumbar TDR using ProDisc-L® prosthesis. Thirty-five consecutive patients, who underwent lumbar TDR using ProDisc-L®, completed minimum 24 months follow-up. Segmental translation was assessed postoperatively at 1 month and at least at 24 months by using dynamic plain radiograph. Segmental translation was assessed in relation to patient age, sex, change of functional spinal unit (FSU) height, segmental range of motion (ROM), global lumbar ROM, implanted level, relative prosthesis size and prosthesis position. The comparison of segmental translation between progressive facet arthrosis (PFA) group and non-PFA group was also made. The mean segmental translation was 0.49±0.49 mm at 1 month after surgery and showed significant increase to 0.83±0.78 mm at last follow-up (P=0.014). Change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis were the significant factors among the variables related to segmental translation that authors assessed (P=0.032, P=0.000, P=0.001, P=0.046 and P=0.042, respectively). There was no significant intergroup difference of mean segmental translation between PFA group and non-PFA group (P=0.586). This study demonstrates that segmental translation after TDR using ProDisc-L® has significant relations with change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis. With the intergroup comparison, PFA group did not show significant higher segmental translation than non-PFA group.

  19. Parametric modeling of the intervertebral disc space in 3D: application to CT images of the lumbar spine.

    Science.gov (United States)

    Korez, Robert; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-10-01

    Gradual degeneration of intervertebral discs of the lumbar spine is one of the most common causes of low back pain. Although conservative treatment for low back pain may provide relief to most individuals, surgical intervention may be required for individuals with significant continuing symptoms, which is usually performed by replacing the degenerated intervertebral disc with an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study, we propose a method for parametric modeling of the intervertebral disc space in three dimensions (3D) and show its application to computed tomography (CT) images of the lumbar spine. The initial 3D model of the intervertebral disc space is generated according to the superquadric approach and therefore represented by a truncated elliptical cone, which is initialized by parameters obtained from 3D models of adjacent vertebral bodies. In an optimization procedure, the 3D model of the intervertebral disc space is incrementally deformed by adding parameters that provide a more detailed morphometric description of the observed shape, and aligned to the observed intervertebral disc space in the 3D image. By applying the proposed method to CT images of 20 lumbar spines, the shape and pose of each of the 100 intervertebral disc spaces were represented by a 3D parametric model. The resulting mean (±standard deviation) accuracy of modeling was 1.06±0.98mm in terms of radial Euclidean distance against manually defined ground truth points, with the corresponding success rate of 93% (i.e. 93 out of 100 intervertebral disc spaces were modeled successfully). As the resulting 3D models provide a description of the shape of intervertebral disc spaces in a complete parametric form, morphometric analysis was straightforwardly enabled and allowed the computation of the corresponding

  20. Bone marrow mesenchymal stem cells differentiation and proliferation on the surface of coral implant

    International Nuclear Information System (INIS)

    Al-Salihi, K.A.; Samsudin, A.R.

    2004-01-01

    This study was designed to evaluate the ability of natural coral implant to provide an environment for marrow cells to differentiate into osteoblasts and function suitable for mineralized tissue formation. DNA content, alkaline phosptatase (ALP) activity, calcium (Ca) content and mineralized nodules, were measured at day 3, day 7 and day 14, in rat bone marrow stromal cells cultured with coral discs glass discs, while cells alone and coral disc alone cultured as control. DNA content, ALP activity, Ca content measurements showed no difference between coral, glass and cells groups at 3 day which were higher than control (coral disc alone), but there were higher asurement at day 7 and 14 in the cell cultured on coral than on glass discs, control cells and control coral discs. Mineralized nodules formation (both in area and number) was more predominant on the coral surface than in control groups. These results showed that natural coral implant provided excellent and favorable situation for marrow cell to differentiate to osteoblasts, lead to large amount of mineralized tissue formation on coral surface. This in vitro result could explain the rapid bone bonding of coral in vivo. (Author)

  1. A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.

    Science.gov (United States)

    Leuridan, Steven; Goossens, Quentin; Roosen, Jorg; Pastrav, Leonard; Denis, Kathleen; Mulier, Michiel; Desmet, Wim; Vander Sloten, Jos

    2017-02-01

    Accurate pre-clinical evaluation of the initial stability of new cementless hip stems using in vitro micromotion measurements is an important step in the design process to assess the new stem's potential. Several measuring systems, linear variable displacement transducer-based and other, require assuming bone or implant to be rigid to obtain micromotion values or to calculate derived quantities such as relative implant tilting. An alternative linear variable displacement transducer-based measuring system not requiring a rigid body assumption was developed in this study. The system combined advantages of local unidirectional and frame-and-bracket micromotion measuring concepts. The influence and possible errors that would be made by adopting a rigid body assumption were quantified. Furthermore, as the system allowed emulating local unidirectional and frame-and-bracket systems, the influence of adopting rigid body assumptions were also analyzed for both concepts. Synthetic and embalmed bone models were tested in combination with primary and revision implants. Single-legged stance phase loading was applied to the implant - bone constructs. Adopting a rigid body assumption resulted in an overestimation of mediolateral micromotion of up to 49.7μm at more distal measuring locations. Maximal average relative rotational motion was overestimated by 0.12° around the anteroposterior axis. Frontal and sagittal tilting calculations based on a unidirectional measuring concept underestimated the true tilting by an order of magnitude. Non-rigid behavior is a factor that should not be dismissed in micromotion stability evaluations of primary and revision femoral implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Comparison of Animal Discs Used in Disc Research to Human Lumbar Disc: Torsion Mechanics and Collagen Content

    Science.gov (United States)

    Showalter, Brent L.; Beckstein, Jesse C.; Martin, John T.; Beattie, Elizabeth E.; Orías, Alejandro A. Espinoza; Schaer, Thomas P.; Vresilovic, Edward J.; Elliott, Dawn M.

    2012-01-01

    Study Design Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these to the human disc. Objective To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. Summary of Background Data There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Methods Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar, and cow, rat, and mouse caudal. Collagen content was measured and normalized by dry weight for the same discs except the rat and mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Results Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Conclusion Disc torsion mechanics are comparable to human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented is useful for selecting and interpreting results for animal models of the disc. Structural composition of the disc, such as initial fiber angle, may explain the differences that were noted between species after geometric normalization. PMID:22333953

  3. Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease.

    Science.gov (United States)

    Noh, Sung Hyun; Zhang, Ho Yeol

    2018-01-25

    We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease. We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 patients), or a titanium plate with a polyetheretherketone (PEEK) cage (71 patients). We conducted a retrospective study to compare the clinical and radiological results among the three groups. The length of the operation, intraoperative blood loss, and duration of hospitalization were significantly lower in the Perfect-C group than in the Zero-P and plate-with-cage groups (P Zero-P groups but was noted in 21 cases (30%) in the plate-with-cage group. The cephalad and caudal plate-to-disc distance (PDD) and the cephalad and caudal PDD/anterior body height (ABH) were significantly greater in the Perfect-C and Zero-P groups than in the plate-with-cage group (P Zero-P group, and in 15 cases (21%) in the plate-with-cage group. Fusion occurred in 37 cases (90%) in the Perfect-C group, in 31 cases (86%) in the Zero-P group, and in 68 cases (95%) in the plate-with-cage group. The Perfect-C, Zero-P, and plate-with-cage devices are effective for treating single-level cervical degenerative disc disease. However, the Perfect-C implant has many advantages over both the Zero-P implant and conventional plate-cage treatments. The Perfect-C implant was associated with shorter operation times and hospitalization durations, less blood loss, and lower subsidence rates compared with the Zero-P implant or the titanium plate with a PEEK cage.

  4. The age-velocity dispersion relation of the Galactic discs from LAMOST-Gaia data

    Science.gov (United States)

    Yu, Jincheng; Liu, Chao

    2018-03-01

    We present the age-velocity dispersion relation (AVR) in three dimensions in the solar neighbourhood using 3564 commonly observed sub-giant/red giant branch stars selected from The Large Sky Area Multi-Object Fiber Spectroscopic Telescope, which gives the age and radial velocity, and Gaia, which measures the distance and proper motion. The stars are separated into metal-poor ([Fe/H] -0.2 dex) groups, so that the metal-rich stars are mostly α-poor, while the metal-poor group are mostly contributed by α-enhanced stars. Thus, the old and metal-poor stars likely belong to the chemically defined thick disc population, while the metal-rich sample is dominated by the thin disc. The AVR for the metal-poor sample shows an abrupt increase at ≳7 Gyr, which is contributed by the thick disc component. On the other hand, most of the thin disc stars with [Fe/H] > -0.2 dex display a power-law-like AVR with indices of about 0.3-0.4 and 0.5 for the in-plane and vertical dispersions, respectively. This is consistent with the scenario that the disc is gradually heated by the spiral arms and/or the giant molecular clouds. Moreover, the older thin disc stars (>7 Gyr) have a rounder velocity ellipsoid, i.e. σϕ/σz is close to 1.0, probably due to the more efficient heating in vertical direction. Particularly for the old metal-poor sample located with |z| > 270 pc, the vertical dispersion is even larger than its azimuthal counterpart. Finally, the vertex deviations and the tilt angles are plausibly around zero with large uncertainties.

  5. Artificial Disc Replacement

    Science.gov (United States)

    ... Spondylolisthesis BLOG FIND A SPECIALIST Treatments Artificial Disc Replacement (ADR) Patient Education Committee Jamie Baisden The disc ... Disc An artificial disc (also called a disc replacement, disc prosthesis or spine arthroplasty device) is a ...

  6. [Epidemiology investigation and biomechanics analyses for the correlation between sacroiliac joint disorder and lumbar intervertebral disc degeneration].

    Science.gov (United States)

    Shi, Ning-Ning; Shen, Guo-Quan; He, Shui-Yong; Guo, Ru-Bao

    2014-07-01

    To study the correlation between lumber disc degeneration and sacroiliac joint disorder, in order to provides a new understanding concepts and therapeutic approach for the prevention and treatment of chronic intractable low back pain. From August 2009 to October 2010,129 cases with lumbar disc herniation were studied with epidemiological methods. Among them, 61 patients with L4, disc herniation included 37 males and 24 females, ranging in aged from 20 to 75 years old, duration of the disease ranged from 1 to 144 months; The other 68 patients with L5S1 disc herniation included 32 males and 36 females,ranging in aged froml8 to 76 years old,duration of the disease ranged from 0.5 to 240 months. The clinical data, symptoms and signs,X-ray characteristics of lumbar spine and pelvis of the patients were investigated by epidemiological. The risk of lumbar disc herniation was calculated with case-control study; independent variables were screened with single factor analysis; the risk factors for lumbar disc herniation were determined with logistic regression analysis, and biomechanics analyses were taken. Among 129 patients with lumbar disc herniation, 88 cases associated with sacroiliac joint disorders, sacroiliac joint disorder was a risk factor of lumbar disc herniation (OR = 4.61, P = 0.00); 47 cases associated with sacroiliac joint disorders in 61 patients with L4,5 disc herniation, iliac crest uneven caused by iliac rotational displacement was a high risk factor of L4,5 disc herniation (OR = 11.27, P = 0.00); 41 cases associated with sacroiliac joint disorders in 68 patients with L5S1 disc herniation, lumbar sacral angle abnormalities caused by sacral tilt shift was a high risk factor L5S1 disc herniation (OR = 2.31, P = 0.03). Lumbar disc herniation and sacroiliac joint disorder are two of fallot, the two factors affect each other and there is a causal relationship. They are common exists in low back pain.

  7. A new computationally-efficient two-dimensional model for boron implantation into single-crystal silicon

    International Nuclear Information System (INIS)

    Klein, K.M.; Park, C.; Yang, S.; Morris, S.; Do, V.; Tasch, F.

    1992-01-01

    We have developed a new computationally-efficient two-dimensional model for boron implantation into single-crystal silicon. This paper reports that this new model is based on the dual Pearson semi-empirical implant depth profile model and the UT-MARLOWE Monte Carlo boron ion implantation model. This new model can predict with very high computational efficiency two-dimensional as-implanted boron profiles as a function of energy, dose, tilt angle, rotation angle, masking edge orientation, and masking edge thickness

  8. Tilt angles and positive response of head-up tilt test in children with orthostatic intolerance.

    Science.gov (United States)

    Lin, Jing; Wang, Yuli; Ochs, Todd; Tang, Chaoshu; Du, Junbao; Jin, Hongfang

    2015-01-01

    This study aimed at examining three tilt angle-based positive responses and the time to positive response in a head-up tilt test for children with orthostatic intolerance, and the psychological fear experienced at the three angles during head-up tilt test. A total of 174 children, including 76 boys and 98 girls, aged from 4 to 18 years old (mean 11.3±2.8 years old), with unexplained syncope, were randomly divided into three groups, to undergo head-up tilt test at the angles of 60°, 70° and 80°, respectively. The diagnostic rates and times were analysed, and Wong-Baker face pain rating scale was used to access the children's psychological fear. There were no significant differences in diagnostic rates of postural orthostatic tachycardia syndrome and vasovagal syncope at different tilt angles during the head-up tilt test (p>0.05). There was a significant difference, however, in the psychological fear at different tilt angles utilising the Kruskal-Wallis test (χ2=36.398, ptest (ptest for vasovagal syncope or for postural orthostatic tachycardia syndrome. Hence, it is suggested that a tilt angle of 60° and head-up tilt test time of 45 minutes should be suitable for children with vasovagal syncope.

  9. Comparison of 2 Zero-Profile Implants in the Treatment of Single-Level Cervical Spondylotic Myelopathy: A Preliminary Clinical Study of Cervical Disc Arthroplasty versus Fusion.

    Directory of Open Access Journals (Sweden)

    Sheng Shi

    Full Text Available Cervical disc arthroplasty (CDA with Discover prosthesis or anterior cervical discectomy and fusion (ACDF with Zero-P cage has been widely used in the treatment of cervical spondylotic myelopathy (CSM. However, little is known about the comparison of the 2 zero-profile implants in the treatment of single-level CSM. The aim was to compare the clinical outcomes and radiographic parameters of CDA with Discover prosthesis and ACDF with Zero-P cage for the treatment of single-level CSM.A total of 128 consecutive patients who underwent 1-level CDA with Discover prosthesis or ACDF with Zero-P cage for single-level CSM between September 2009 and December 2012 were included in this study. Clinical outcomes were evaluated using the Japanese Orthopaedic Association (JOA score and Neck Disability Index (NDI. For radiographic assessment, the overall sagittal alignment (OSA, functional spinal unit (FSU angle, and range of motion (ROM at the index and adjacent levels were measured before and after surgery. Additionally, the complications were also recorded.Both treatments significantly improved all clinical parameters (P 0.05. Besides, no significant differences existed in dysphagia, subsidence, or adjacent disc degeneration between the 2 groups (P > 0.05. However, significant differences occurred in prosthesis migration in CDA group.The results of this study showed that clinical outcomes and radiographic parameters were satisfactory and comparable with the 2 techniques. However, more attention to prosthesis migration of artificial cervical disc should be paid in the postoperative early-term follow-up.

  10. Bacterial recovery using sonication versus swabbing of titanium and stainless steel implants inoculated with Staphylococcus pseudintermedius or Pseudomonas aeruginosa.

    Science.gov (United States)

    Keeshen, Thomas; Case, J Brad; Wellehan, James F; Dujowich, Mauricio

    2017-09-12

    To evaluate the use of sonication to improve recovery of bacteria from metal discs infected with bacteria commonly associated with implant infections in veterinary medicine. In vitro study in which sterile titanium (Ti6Al4V) and stainless steel (AIS1316-L) discs were incubated with either Staphylococcus pseudintermedius or Pseudomonas aeruginosa for 24 hours. The following three groups were compared: 1) the sonication group involved immersing the discs in sterile saline and sonicating for five minutes; 2) the sham group was considered a negative control in which the discs were immersed in saline for five minutes without sonication; and 3) the swab group involved systematically swabbing the implant with a sterile culturette. All samples were plated on blood agar and incubated for 24 hours. Colonies were then counted and compared. For both species of bacteria, there was a significant increase in bacterial colonies isolated using sonication compared to the other two study groups (p = 0.0001). No differences in bacterial growth were found between the two types of metal implants. There was a significant increase in bacterial colony counts for S. pseudintermedius when comparing the swab group versus the sham group, but this was not significant for P. aeruginosa. Sonication significantly improves recovery of bacteria commonly associated with veterinary implant-associated surgical site infections compared to swabbing of implants in vitro. A prospective clinical evaluation is indicated to determine the in vivo efficacy of sonication in veterinary patients.

  11. [Research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration].

    Science.gov (United States)

    Liang, Hang; Deng, Xiangyu; Shao, Zengwu

    2017-10-01

    To summarize the research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration and deduce the therapeutic potential of endogenous repair for intervertebral disc degeneration. The original articles about intervertebral disc endogenous stem cells for intervertebral disc regeneration were extensively reviewed; the reparative potential in vivo and the extraction and identification in vitro of intervertebral disc endogenous stem cells were analyzed; the prospect of endogenous stem cells for intervertebral disc regeneration was predicted. Stem cell niche present in the intervertebral discs, from which stem cells migrate to injured tissues and contribute to tissues regeneration under certain specific microenvironment. Moreover, the migration of stem cells is regulated by chemokines system. Tissue specific progenitor cells have been identified and successfully extracted and isolated. The findings provide the basis for biological therapy of intervertebral disc endogenous stem cells. Intervertebral disc endogenous stem cells play a crucial role in intervertebral disc regeneration. Therapeutic strategy of intervertebral disc endogenous stem cells is proven to be a promising biological approach for intervertebral disc regeneration.

  12. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    Science.gov (United States)

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  13. Temporal Analyses of the Response of Intervertebral Disc Cells and Mesenchymal Stem Cells to Nutrient Deprivation

    Directory of Open Access Journals (Sweden)

    Sarah A. Turner

    2016-01-01

    Full Text Available Much emphasis has been placed recently on the repair of degenerate discs using implanted cells, such as disc cells or bone marrow derived mesenchymal stem cells (MSCs. This study examines the temporal response of bovine and human nucleus pulposus (NP cells and MSCs cultured in monolayer following exposure to altered levels of glucose (0, 3.15, and 4.5 g/L and foetal bovine serum (0, 10, and 20% using an automated time-lapse imaging system. NP cells were also exposed to the cell death inducers, hydrogen peroxide and staurosporine, in comparison to serum starvation. We have demonstrated that human NP cells show an initial “shock” response to reduced nutrition (glucose. However, as time progresses, NP cells supplemented with serum recover with minimal evidence of cell death. Human NP cells show no evidence of proliferation in response to nutrient supplementation, whereas MSCs showed greater response to increased nutrition. When specifically inducing NP cell death with hydrogen peroxide and staurosporine, as expected, the cell number declined. These results support the concept that implanted NP cells or MSCs may be capable of survival in the nutrient-poor environment of the degenerate human disc, which has important clinical implications for the development of IVD cell therapies.

  14. Feasibility of using interstitial ultrasound for intradiscal thermal therapy: a study in human cadaver lumbar discs

    International Nuclear Information System (INIS)

    Nau, William H; Diederich, Chris J; Shu, Richard

    2005-01-01

    Application of heat in the spine using resistive wire heating devices is currently being used clinically for minimally invasive treatment of discogenic low back pain. In this study, interstitial ultrasound was evaluated for the potential to heat intradiscal tissue more precisely by directing energy towards the posterior annular wall while avoiding vertebral bodies. Two single-element directional applicator design configurations were tested: a 1.5 mm OD direct-coupled (DC) applicator which can be implanted directly within the disc, and a catheter-cooled (CC) applicator which is inserted in a 2.4 mm OD catheter with integrated water cooling and implanted within the disc. The transducers were sectored to produce 90 deg. spatial heating patterns for directional control. Both applicator configurations were evaluated in four human cadaver lumbar disc motion segments. Two heating protocols were employed in this study in which the temperature measured 5 mm away from the applicator was controlled to either T = 52 deg. C, or T > 70 deg. C for the treatment period. These temperatures (thermal doses) are representative of those required for thermal necrosis of in-growing nociceptor nerve fibres and disc cellularity alone, or with coagulation and restructuring of annular collagen in the high-temperature case. Steady-state temperature maps, and thermal doses (t 43 ) were used to assess the thermal treatments. Results from these studies demonstrated the capability of controlling temperature distributions within selected regions of the disc and annular wall using interstitial ultrasound, with minimal vertebral end-plate heating. While directional heating was demonstrated with both applicator designs, the CC configuration had greater directional heating capabilities and offered better temperature control than the DC configuration, particularly during the high-temperature protocol. Further, ultrasound energy was capable of penetrating within the highly attenuating disc tissue to

  15. Optimum Tilt Angle at Tropical Region

    Directory of Open Access Journals (Sweden)

    S Soulayman

    2015-02-01

    Full Text Available : One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. Meanwhile, is the rule of thumb, which says that solar collector Equator facing position is the best, is valid for tropical region? Thus, it is required to determine the optimum tilt as for Equator facing and for Pole oriented collectors. In addition, the question that may arise: how many times is reasonable for adjusting collector tilt angle for a definite value of surface azimuth angle? A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle for the solar collector at any latitude. This model was applied for determining optimum tilt angle and orientation in the tropical zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of 11% to 18% more than the case of a solar collector fixed on a horizontal surface.

  16. Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation.

    Science.gov (United States)

    Pesce, Paolo; Pera, Francesco; Setti, Paolo; Menini, Maria

    To evaluate the accuracy and precision of a digital scanner used to scan four implants positioned according to an immediate loading implant protocol and to assess the accuracy of an aluminum framework fabricated from a digital impression. Five master casts reproducing different edentulous maxillae with four tilted implants were used. Four scan bodies were screwed onto the low-profile abutments, and a digital intraoral scanner was used to perform five digital impressions of each master cast. To assess trueness, a metal framework of the best digital impression was produced with computer-aided design/computer-assisted manufacture (CAD/CAM) technology and passive fit was assessed with the Sheffield test. Gaps between the frameworks and the implant analogs were measured with a stereomicroscope. To assess precision, three-dimensional (3D) point cloud processing software was used to measure the deviations between the five digital impressions of each cast by producing a color map. The deviation values were grouped in three classes, and differences were assessed between class 2 (representing lower discrepancies) and the assembled classes 1 and 3 (representing the higher negative and positive discrepancies, respectively). The frameworks showed a mean gap of 3D point cloud software, with higher frequencies of points in class 2 than in grouped classes 1 and 3 (P impression may represent a reliable method for fabricating full-arch implant frameworks with good passive fit when tilted implants are present.

  17. Tilting Saturn without Tilting Jupiter: Constraints on Giant Planet Migration

    Science.gov (United States)

    Brasser, R.; Lee, Man Hoi

    2015-11-01

    The migration and encounter histories of the giant planets in our solar system can be constrained by the obliquities of Jupiter and Saturn. We have performed secular simulations with imposed migration and N-body simulations with planetesimals to study the expected obliquity distribution of migrating planets with initial conditions resembling those of the smooth migration model, the resonant Nice model and two models with five giant planets initially in resonance (one compact and one loose configuration). For smooth migration, the secular spin-orbit resonance mechanism can tilt Saturn’s spin axis to the current obliquity if the product of the migration timescale and the orbital inclinations is sufficiently large (exceeding 30 Myr deg). For the resonant Nice model with imposed migration, it is difficult to reproduce today’s obliquity values, because the compactness of the initial system raises the frequency that tilts Saturn above the spin precession frequency of Jupiter, causing a Jupiter spin-orbit resonance crossing. Migration timescales sufficiently long to tilt Saturn generally suffice to tilt Jupiter more than is observed. The full N-body simulations tell a somewhat different story, with Jupiter generally being tilted as often as Saturn, but on average having a higher obliquity. The main obstacle is the final orbital spacing of the giant planets, coupled with the tail of Neptune’s migration. The resonant Nice case is barely able to simultaneously reproduce the orbital and spin properties of the giant planets, with a probability ˜ 0.15%. The loose five planet model is unable to match all our constraints (probability <0.08%). The compact five planet model has the highest chance of matching the orbital and obliquity constraints simultaneously (probability ˜0.3%).

  18. Disc operational system

    International Nuclear Information System (INIS)

    Veretenov, V.Yu.; Volkov, A.I.; Gurevich, M.I.; Kozik, V.S.; Pod'yachev, E.I.; Shapiro, M.L.

    1974-01-01

    A disc operational system is proposed, which is based on the file structure and designed for use in a BESM-6 computer with the software system comprising a dispatcher DD-73 and a monitor 'Dubna'. The main distinguishing feature of the disc operational system is the decentralization of the file system. Each disc package is an independent file unaffected by the state of the other disc packages. The use of several disc packages is allowed. The above feature of the disc operational system makes it possible to simplify the language of communication with the system, to give the user the opportunity of controlling the file quite independently, and to simplify the maintenance of the discs by the computer personnel. One and the same disc can be simultaneously addressed by all problems in the processor (both mathematical and service). A single file, however, may be used in the recording mode by only one problem. The description presented is the instruction for users. It also describes special possibilities open to the system programmers [ru

  19. Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten

    Energy Technology Data Exchange (ETDEWEB)

    Biederer, J; Hutzelmann, A; Heller, M [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie; Rama, B [Paracelsus Klinik, Osnabrueck (Germany). Klinik fuer Neurochirurgie

    1999-08-01

    Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with local symptoms can be evaluated with follow-up X-rays and functional imaging. (orig.) [German] Ziel: An Patienten mit zervikalen Kompressionssyndromen wurden Stellung und Funktion der Halswirbelsaeule nach Diskektomie und Fusion mit einem neuartigen Titaninterponat untersucht. Patienten und Methoden: Bei 37 Patienten (42 Segmente) wurden praeoperativ sowie 4 Tage, 6 Wochen und 7 Monate postoperativ mit seitlichen Uebersichts- und Funktionsaufnahmen Stellung und Mobilitaet der HWS beurteilt. Erfasst wurden Lageveraenderungen des Titaninterponates und die Reaktion der angrenzenden Wirbelkoerperabschlussplatten. Ergebnisse: Das Titaninterponat bewirkte postoperativ eine

  20. Molecular tilt on monolayer-protected nanoparticles

    KAUST Repository

    Giomi, L.

    2012-02-01

    The structure of the tilted phase of monolayer-protected nanoparticles is investigated by means of a simple Ginzburg-Landau model. The theory contains two dimensionless parameters representing the preferential tilt angle and the ratio ε between the energy cost due to spatial variations in the tilt of the coating molecules and that of the van der Waals interactions which favors the preferential tilt. We analyze the model for both spherical and octahedral particles. On spherical particles, we find a transition from a tilted phase, at small ε, to a phase where the molecules spontaneously align along the surface normal and tilt disappears. Octahedral particles have an additional phase at small ε characterized by the presence of six topological defects. These defective configurations provide preferred sites for the chemical functionalization of monolayer-protected nanoparticles via place-exchange reactions and their consequent linking to form molecules and bulk materials. Copyright © EPLA, 2012.

  1. Molecular tilt on monolayer-protected nanoparticles

    KAUST Repository

    Giomi, L.; Bowick, M. J.; Ma, X.; Majumdar, A.

    2012-01-01

    The structure of the tilted phase of monolayer-protected nanoparticles is investigated by means of a simple Ginzburg-Landau model. The theory contains two dimensionless parameters representing the preferential tilt angle and the ratio ε between the energy cost due to spatial variations in the tilt of the coating molecules and that of the van der Waals interactions which favors the preferential tilt. We analyze the model for both spherical and octahedral particles. On spherical particles, we find a transition from a tilted phase, at small ε, to a phase where the molecules spontaneously align along the surface normal and tilt disappears. Octahedral particles have an additional phase at small ε characterized by the presence of six topological defects. These defective configurations provide preferred sites for the chemical functionalization of monolayer-protected nanoparticles via place-exchange reactions and their consequent linking to form molecules and bulk materials. Copyright © EPLA, 2012.

  2. An efficient eikonal solver for tilted transversely isotropic and tilted orthorhombic media

    KAUST Repository

    Waheed, Umair bin

    2014-01-01

    Computing first-arrival traveltimes in the presence of anisotropy is important for high-end near surface modeling, microseismic source localization, and fractured reservoir characterization. Anisotropy deviating from elliptical anisotropy introduces higher-order nonlinearity into the eikonal equation, which makes solving the equation a challenging task. We address this challenge by iteratively solving a sequence of simpler tilted elliptically anisotropic eikonal equations. At each iteration, the source function is updated to capture the effects due to the higher order nonlinear terms in the anisotropy. We use Aitken extrapolation to speed up the convergence rate of the iterative algorithm. The result is an efficient algorithm for firstarrival traveltime computations in tilted anisotropic media. We demonstrate the proposed method for the tilted transversely isotropic media and the tilted orthorhombic media. Numerical tests show that the proposed method is feasible and produces results that are comparable to wavefield extrapolation, even for strongly anisotropic and complex structures. Therefore, for the cases where one or two-point ray tracing fails, our method may be a potential substitute for computing traveltimes.

  3. Fluid observers and tilting cosmology

    International Nuclear Information System (INIS)

    Coley, A A; Hervik, S; Lim, W C

    2006-01-01

    We study perfect fluid cosmological models with a constant equation of state parameter γ in which there are two naturally defined timelike congruences, a geometrically defined geodesic congruence and a non-geodesic fluid congruence. We establish an appropriate set of boost formulae relating the physical variables, and consequently the observed quantities, in the two frames. We study expanding spatially homogeneous tilted perfect fluid models, with an emphasis on future evolution with extreme tilt. We show that for ultra-radiative equations of state (i.e. γ > 4/3), generically the tilt becomes extreme at late times and the fluid observers will reach infinite expansion within a finite proper time and experience a singularity similar to that of the big rip. In addition, we show that for sub-radiative equations of state (i.e. γ < 4/3), the tilt can become extreme at late times and give rise to an effective quintessential equation of state. To establish the connection with phantom cosmology and quintessence, we calculate the effective equation of state in the models under consideration and we determine the future asymptotic behaviour of the tilting models in the fluid frame variables using the boost formulae. We also discuss spatially inhomogeneous models and tilting spatially homogeneous models with a cosmological constant

  4. Evaluating Tilt for Wind Farms: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Annoni, Jennifer; Scholbrock, Andrew; Churchfield, Matthew; Fleming, Paul

    2017-06-29

    The objective of this work is to demonstrate the feasibility of tilt in a wind plant. Tilt control, much like other wind plant control strategies, has the potential to improve the performance of a wind plant. Tilt control uses the tilt angle of the turbine to direct the wake above or below the downstream turbines. This paper presents a study of tilt in two- and threeturbine arrays. Specifically, the authors show that the power production of a two-turbine array can be increased by tilting turbines in a specific orientation. When adding more turbines, as is shown with the three-turbine array, the overall percentage of power gain increases. This outcome deviates from some of the results seen in typical wind plant control strategies. Finally, we discuss the impact this type of control strategy has on the aerodynamics in a wind plant. This analysis demonstrates that a good understanding of wake characteristics is necessary to improve the plant's performance. A tilt strategy such as the one presented in this paper may have implications for future control/optimization studies including optimization of hub heights in a wind plant and analysis of deep array effects.

  5. Direct cone beam SPECT reconstruction with camera tilt

    International Nuclear Information System (INIS)

    Jianying Li; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.; Zongjian Cao; Tsui, B.M.W.

    1993-01-01

    A filtered backprojection (FBP) algorithm is derived to perform cone beam (CB) single-photon emission computed tomography (SPECT) reconstruction with camera tilt using circular orbits. This algorithm reconstructs the tilted angle CB projection data directly by incorporating the tilt angle into it. When the tilt angle becomes zero, this algorithm reduces to that of Feldkamp. Experimentally acquired phantom studies using both a two-point source and the three-dimensional Hoffman brain phantom have been performed. The transaxial tilted cone beam brain images and profiles obtained using the new algorithm are compared with those without camera tilt. For those slices which have approximately the same distance from the detector in both tilt and non-tilt set-ups, the two transaxial reconstructions have similar profiles. The two-point source images reconstructed from this new algorithm and the tilted cone beam brain images are also compared with those reconstructed from the existing tilted cone beam algorithm. (author)

  6. High energy P implants in silicon

    International Nuclear Information System (INIS)

    Raineri, V.; Cacciato, A.; Benyaich, F.; Priolo, F.; Rimini, E.; Galvagno, G.; Capizzi, S.

    1992-01-01

    Phosphorus ions in the energy range 0.25-1 MeV and in the dose range 2x10 13 -1x10 15 P/cm 2 were implanted into (100) Si single crystal at different tilt angles. In particular channeling and random conditions were investigated. For comparison some implants were performed on samples with a 2 μm thick surface amorphous layer. Chemical concentration P profiles were obtained by secondary ion mass spectrometry. Carrier concentration and mobility profile measurements were carried out by sheet resistance and Hall measurements on implanted van der Pauw patterns. Carrier concentration profiles were also obtained by spreading resistance (SR) measurements. The damage in the as-implanted samples was determined by backscattering and channeling spectrometry (RBS) as a function of the dose and implantation energy. Comparison of random implants in crystal with implants in amorphous layers shows that in the first case it is impossible to completely avoid the channeling tail. In the implants performed under channeling conditions at low doses the P profiles are flat over more than 2 μm thick layers. Furthermore, by increasing the implanted dose, the shape of the profiles dramatically changes due to the dechanneling caused by the crystal disorder. The data are discussed and compared with Monte Carlo simulations using the MARLOWE code. A simple description of the electronic energy loss provides an excellent agreement between the calculated and experimental profiles. (orig.)

  7. Transient inhibition of connective tissue infiltration and collagen deposition into porous poly(lactic-co-glycolic acid) discs.

    Science.gov (United States)

    Love, Ryan J; Jones, Kim S

    2013-12-01

    Connective tissue rapidly proliferates on and around biomaterials implanted in vivo, which impairs the function of the engineered tissues, biosensors, and devices. Glucocorticoids can be utilized to suppress tissue ingrowth, but can only be used for a limited time because they nonselectively arrest cell proliferation in the local environment. The present study examined use of a prolyl-4-hydroxylase inhibitor, 1,4-dihydrophenonthrolin-4-one-3-carboxylic acid (1,4-DPCA), to suppress connective tissue ingrowth in porous PLGA discs implanted in the peritoneal cavity for 28 days. The prolyl-4-hydroxylase inhibitor was found to be effective at inhibiting collagen deposition within and on the outer surface of the disc, and also limited connective tissue ingrowth, but not to the extent of glucocorticoid inhibition. Finally, it was discovered that 1,4-DPCA suppressed Scavenger Receptor A expression on a macrophage-like cell culture, which may account for the drug's ability to limit connective tissue ingrowth in vivo. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  8. 3D microscopy of hydrogen and magnetic force on proton implanted microstructures in graphite

    International Nuclear Information System (INIS)

    Reichart, P.; Cluitmans, J.F.J.; Pakes, C.; Orbons, S.; Jamieson, D.N.

    2005-01-01

    We investigated the depth dependence of magnetic signals in proton irradiated graphite using a tilted microspot implantation followed by combined AFM/MFM analysis. This study is motivated by the not yet independently reproduced discovery of ferromagnetism in carbon materials created by proton irradiation. We present results of 3D hydrogen analysis of pristine and irradiated highly oriented pyrolytic graphite (HOPG). These results, previously presented in collaboration with universities in Leipzig and Munich, are summarized here and reveal a hydrogen level in pristine HOPG less than 0.3 at-ppm and that 2.25 MeV implanted hydrogen is located within a peak confined to the end of range with no evidence of diffusion broadening. For implanted microspots, up to 40 at-% of the implanted hydrogen is not detected, providing support for lateral hydrogen diffusion. Up to 10 16 H-atoms/cm 2 are detected in the near-surface region on all samples, which has not yet been considered in possible mechanisms for creation of ferromagnetism. As theoretical models propose that hydrogen could play a major role in carbon ferromagnetism, this result raises the hypothesis for an effect restricted to the surface. Our preliminary data on magnetic force microscopy of tilted implants show a strong magnetic phase shift localized on the beam entrance point only. (author). 14 refs., 5 figs

  9. Unilateral otolith centrifugation by head tilt.

    Science.gov (United States)

    Winters, Stephanie M; Bos, Jelte E; Klis, Sjaak F L

    2014-01-01

    To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. To test a new, more simple method of unilateral stimulation with head tilt and the body remaining on axis. During stationary and during 360 deg/s rotation, 12 healthy blindfolded subjects had their heads tilted 30 degrees sideways, positioning one otolithic organ on the axis of rotation after the other. The haptic subjective vertical (SV) was recorded several times by means of a manually adjustable rod. It was found that during stationary the SV tilted about 4 degrees on average in the direction of the head. During rotation, the SV tilted about 9 degrees on average. We therefore estimate the effect of eccentric otolith rotation to be 5 degrees on average. Tilt of the subjective vertical induced by head tilt during on-axis body rotation can provide a relatively uncomplicated alternative to test unilateral otolithic function as compared to body and head translation during rotation. Moreover, unlike eccentric rotation of the entire body, somatosensory cues are minimized by keeping the body fixed on axis and by subtracting the effect of head tilt per se.

  10. Star-disc interaction in galactic nuclei: formation of a central stellar disc

    Science.gov (United States)

    Panamarev, Taras; Shukirgaliyev, Bekdaulet; Meiron, Yohai; Berczik, Peter; Just, Andreas; Spurzem, Rainer; Omarov, Chingis; Vilkoviskij, Emmanuil

    2018-05-01

    We perform high-resolution direct N-body simulations to study the effect of an accretion disc on stellar dynamics in an active galactic nucleus (AGN). We show that the interaction of the nuclear stellar cluster (NSC) with the gaseous accretion disc (AD) leads to formation of a stellar disc in the central part of the NSC. The accretion of stars from the stellar disc on to the super-massive black hole is balanced by the capture of stars from the NSC into the stellar disc, yielding a stationary density profile. We derive the migration time through the AD to be 3 per cent of the half-mass relaxation time of the NSC. The mass and size of the stellar disc are 0.7 per cent of the mass and 5 per cent of the influence radius of the super-massive black hole. An AD lifetime shorter than the migration time would result in a less massive nuclear stellar disc. The detection of such a stellar disc could point to past activity of the hosting galactic nucleus.

  11. Influence of forming conditions on fiber tilt

    Science.gov (United States)

    David W. Vahey; John M. Considine; Michael A. and MacGregor

    2013-01-01

    Fiber tilt describes the projection of fiber length in the thickness direction of paper. The projection is described by the tilt angle of fibers with respect to the plane of the sheet. A simple model for fiber tilt is based on jet-to-wire velocity differential in combination with cross-flows on the wire. The tilt angle of a fiber is found to vary as the sine of its in-...

  12. Realization of Tip Tilting By 8-Step Line Tilting

    International Nuclear Information System (INIS)

    Chen Yingtian; Zhang Yang; Lim, Boon Ham; Lim, Chen Sin; Hu Sen; Ho, Tso-Hsiu

    2009-01-01

    By direct calculation of rotation matrices of SO(3), we show how certain specific sequence of eight consecutive rotations of digital angles can yield a tilting of a facet mirror. We also design a detailed program specifically to tilt an array of mirrors from planar orientation to the required focusing orientation. We describe how to use the 8-step to realize the focusing of the mirror array. We have found, in our designed program, an important feature of row-sharing during the rotations for the columns and similarly the column-sharing during the rotations for the row. This feature can save a lot of operating time during the actual realization of the mechanical movements.

  13. Usefulness of implantable loop recorder in a patient with syncope during bathing

    Directory of Open Access Journals (Sweden)

    Motohiro Nakao, MD

    2013-02-01

    Full Text Available A 27-year-old man presented to our hospital with a 1-year-hisory of repeated syncope, which particularly occurred while bathing or on a hot day. The head-up tilt test did not induce arrhythmia; however, blood pressure decreased by 39 mm Hg without any symptoms. Given that no bradycardia/tachycardia was induced on electrophysiological study and carotid sinus massage, an implantable loop recorder (ILR was implanted. After 2 months, syncope again occurred during bathing at midnight. Sinus arrest and a maximum ventricular pause of 10.2 s were documented using the ILR. After pacemaker implantation, the patient had not experienced syncope for 14 months.

  14. Tilting mode in field-reversed configurations

    International Nuclear Information System (INIS)

    Schwarzmeier, J.L.; Barnes, D.C.; Lewis, H.R.; Seyler, C.E.; Shestakov, A.I.

    1982-01-01

    Field Reversed Configurations (FRCs) experimentally have exhibited remarkable stability on the magnetohydrodynamic (MHD) timescale, despite numerous MHD calculations showing FRCs to be unstable. It is easy to believe that local modes are stabilized by finite Larmor radius (FLR) effects, but more puzzling is the apparent stability of FRCs against global modes, where one would expect FLR effects to be less important. In this paper we study the tilting mode, which MHD has shown to be a rapidly growing global mode. The tilting mode in FRCs is driven by the pressure gradient, and magnetic compression and field line bending are the stabilizing forces. A schematic of the evolution of the tilting mode is shown. The tilting mode is considered dangerous, because it would lead to rapid tearing across the separatrix. Unlike spheromaks, the tilting mode in FRCs has a separatrix that is fixed in space, so that the mode is strictly internal

  15. Lumbar disc arthroplasty: indications, biomechanics, types, and radiological criteria

    International Nuclear Information System (INIS)

    Baur-Melnyk, A.; Reiser, M.F.; Birkenmaier, C.

    2006-01-01

    Lumbar total disc replacement (TDR) was developed to treat a painful degenerative lumbar motion segment while avoiding the disadvantages of fusion surgery, such as adjacent segment instabilities. Early clinical results with TDR have shown a significant reduction in low back pain and a significant improvement in disability scores. When compared to fusion, the results with TDR tend to be superior in the short-term follow-up and initial rehabilitation is faster. The radiological assessment is an integral part of the preoperative work-up. Plain X-rays of the lumbar spine should be complemented by flexion - extension views in order to assess residual segmental mobility. Computed tomography is used to exclude osteoarthritis of the zygapophyseal joints, Baastrup's disease (kissing spines) and other sources of low back pain. Magnetic resonance imaging is useful to exclude substantial disc protrusions; it allows for the detection of disc dehydration and bone marrow edema in the case of activated spondylochondrosis. If osteoporosis is suspected, an osteodensitometry of the lumbar spine should be performed. Postoperative plain X-rays should include antero-posterior and lateral views as well as flexion - extension views in the later postoperative course. Measurements should determine the disc space height in the lateral view, the segmental and total lumbar lordosis as well as the segmental mobility in the flexion - extension views. The ideal position of a TDR is exactly central in the ap-view and close to the dorsal border of the vertebral endplates in the lateral view. Malpositioning may cause segmental hyperlordosis and unbalanced loading of the endplates with the risk of implant subsidence and migration. (orig.) [de

  16. MR imaging findings of a sequestered disc in the lumbar spine: a comparison with an extruded disc

    International Nuclear Information System (INIS)

    Sim, Su Youn; Park, Ji Seon; Ryu, Kyung Nam; Jin, Wook

    2007-01-01

    To compare the MR findings of a sequestered disc with an extruded disc. MR images of 28 patients with a sequestered disc and 18 patients with an extruded disc were retrospectively reviewed. Patients with sequestered discs were divided into two groups whether definite separation from the parent disc was or was not seen. In the latter group (definite separation not seen) and the extruded disc group of patients, the signal intensities of the herniated discs were compared with the signal intensities of the parent discs and were evaluated on T1-and T2-weighted images. We also assessed the presence of a notch within the herniated disc. In the sequestered disc group of patients (28 discs), only 5 discs (18%) showed obvious separation from the parent disc. Among the remaining 23 discs with indefinite separation, the notch was visible in 14 discs (61%) and 9 discs (39%) had no notch. In the extruded disc group (18 discs), the notch was visible in 2 (11%) discs and the difference between the two groups was statistically significant (ρ 0.0002). The signal intensities of the herniated discs on T1-weighted images were isointense in both the sequestered and extruded discs. The difference of incidence of high signal intensities on T2-weighted images was not statistically significant (ρ = 0.125). It is necessary to consider the possibility of the presence of a sequestered disc when a herniated disc material shows a notch

  17. Instability of warped discs

    Science.gov (United States)

    Doǧan, S.; Nixon, C. J.; King, A. R.; Pringle, J. E.

    2018-05-01

    Accretion discs are generally warped. If a warp in a disc is too large, the disc can `break' apart into two or more distinct planes, with only tenuous connections between them. Further, if an initially planar disc is subject to a strong differential precession, then it can be torn apart into discrete annuli that precess effectively independently. In previous investigations, torque-balance formulae have been used to predict where and when the disc breaks into distinct parts. In this work, focusing on discs with Keplerian rotation and where the shearing motions driving the radial communication of the warp are damped locally by turbulence (the `diffusive' regime), we investigate the stability of warped discs to determine the precise criterion for an isolated warped disc to break. We find and solve the dispersion relation, which, in general, yields three roots. We provide a comprehensive analysis of this viscous-warp instability and the emergent growth rates and their dependence on disc parameters. The physics of the instability can be understood as a combination of (1) a term that would generally encapsulate the classical Lightman-Eardley instability in planar discs (given by ∂(νΣ)/∂Σ < 0) but is here modified by the warp to include ∂(ν1|ψ|)/∂|ψ| < 0, and (2) a similar condition acting on the diffusion of the warp amplitude given in simplified form by ∂(ν2|ψ|)/∂|ψ| < 0. We discuss our findings in the context of discs with an imposed precession, and comment on the implications for different astrophysical systems.

  18. Development of industrial ion implantation technology

    International Nuclear Information System (INIS)

    Choi, Byung Hoh; Jung, Kee Suk; Kim, Wan; Song, Woo Sub; Hwang, Chul Kyoo

    1994-02-01

    We developed an ion implanter fitted for the treatment of 12 inch or larger wafers to make 256 or higher Mega D-Ram wafers. Design features are dual usage of gas/solid for the ion source loading, production of multi-balanced ions, and the possible oxygen ion implantation. BOSII program was used for the ion optics calculation. Beams are triangularly scanned to wafers for the even implantation by a proper magnetic field application. More than 10 mA ion current is produced. For the efficient implantation to be made, target is made to rotate with tilted angle at a displaced axis. High speed tools, diamond tools, precision dies, and razor blades were implanted and the performance was evaluated after two or three times of line application. Of those materials studied, PCB drills and end mills are on the commercial treatment stages. Industrial materials as SKD-11, WC-Co, NAK-55 was compositely treated with ion beam and coating. Resultant properties were analyzed using AES, XRD, and TEM. For the case of xenon ions, excellent TiN coating resulted and its application to microcircuit lead frame increased the performance to more than 30 percent. 94 figs, 29 pix, 19 tabs, 50 refs. (Author)

  19. Development of industrial ion implantation technology

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Byung Hoh; Jung, Kee Suk; Kim, Wan; Song, Woo Sub; Hwang, Chul Kyoo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-02-01

    We developed an ion implanter fitted for the treatment of 12 inch or larger wafers to make 256 or higher Mega D-Ram wafers. Design features are dual usage of gas/solid for the ion source loading, production of multi-balanced ions, and the possible oxygen ion implantation. BOSII program was used for the ion optics calculation. Beams are triangularly scanned to wafers for the even implantation by a proper magnetic field application. More than 10 mA ion current is produced. For the efficient implantation to be made, target is made to rotate with tilted angle at a displaced axis. High speed tools, diamond tools, precision dies, and razor blades were implanted and the performance was evaluated after two or three times of line application. Of those materials studied, PCB drills and end mills are on the commercial treatment stages. Industrial materials as SKD-11, WC-Co, NAK-55 was compositely treated with ion beam and coating. Resultant properties were analyzed using AES, XRD, and TEM. For the case of xenon ions, excellent TiN coating resulted and its application to microcircuit lead frame increased the performance to more than 30 percent. 94 figs, 29 pix, 19 tabs, 50 refs. (Author).

  20. A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures: 113 consecutive patients treated by internal fixation and followed for 1 year

    DEFF Research Database (Denmark)

    Palm, Henrik; Gosvig, Kasper; Krasheninnikoff, Michael

    2009-01-01

    BACKGROUND AND PURPOSE: Preoperative posterior tilt in undisplaced (Garden I-II) femoral neck fractures is thought to influence rates of reoperation. However, an exact method for its measurement has not yet been presented. We designed a new measurement for posterior tilt on preoperative lateral...... radiographs and investigated its association with later reoperation. PATIENTS AND METHODS: A consecutive series of 113 patients, > or = 60 years of age with undisplaced (Garden I-II) femoral neck fractures treated with two parallel implants, was assessed regarding patient characteristics, radiographs...... and able to predict reoperation in patients with undisplaced (Garden I-II) femoral neck fractures....

  1. Finite element study of a lumbar intervertebral disc nucleus replacement device

    Directory of Open Access Journals (Sweden)

    Jessica S Coogan

    2016-12-01

    Full Text Available Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics

  2. Tilt measurements at Vulcano Island

    Directory of Open Access Journals (Sweden)

    B. Saraceno

    2007-06-01

    Full Text Available A network of tiltmeters has been operational on Vulcano Island for numerous years. At present, the network comprises five functioning borehole stations, four of which are installed at 8-10 m and allow recording very stable, high precision signals with very low noise. We report observations over the last 12 years that illustrate impulsive variations linked to seismicity and long-term (several years trends in the signals. We suggest a relationship between tilt changes correlated to the strongest regional seismic events and site acceleration; long-term tilt variations analyzed in combination with other ground deformation data seem to represent the evidence of a contraction of the La Fossa cone. We also analyzed how the tilt device has the capability to detect possible magma migrations; we considered previous studies that have imaged spatially well-defined levels of magma accumulation beneath La Fossa, and Vulcanello; we concluded that the Vulcano tilt network should be capable of detecting the upward migration of small magma volumes. Finally, we show that no evidence of changes are visible on tilt signals during anomalous degassing episodes (linked to a building up input of magmatic fluids at the La Fossa thereby evidencing that no magma migration occurred during such events.

  3. Evolution of viscous discs. 3. Giant discs in symbiotic stars

    Energy Technology Data Exchange (ETDEWEB)

    Bath, G T [Oxford Univ. (UK). Dept. of Astrophysics; Pringle, J E [Cambridge Univ. (UK). Inst. of Astronomy

    1982-10-01

    The structure of time-dependent accretion discs in giant binaries with separation of the order of 10/sup 13/ cm is examined. Radiative ..cap alpha..-viscosity discs with ..cap alpha.. of order unity accreting on to main-sequence stars at accretion rates which generate luminosities greater than a giant companion decay on time-scales of the same order as the binary period, unlike those in dwarf nova binaries which decay on time-scales 100 times longer than the binary period. This results from the lower gravitational potential and consequent larger disc thickness (relative to the radius) of luminous 'giant' discs accreting at high accretion rates. The eruptions of the symbiotic binary C I Cygni are modelled by an ..cap alpha.. = 1 disc with outer radius 8.5 x 10/sup 12/ cm and a sequence of five mass-transfer bursts at rates between 1.5 x 10/sup 21/ and 4 x 10/sup 22/g s/sup -1/.

  4. Superluminous accretion discs

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, M [Cambridge Univ. (UK). Inst. of Astronomy; Polska Akademia Nauk, Warsaw. Centrum Astronomiczne)

    1981-07-01

    Upper limits are computed for the total luminosities and collimation of radiation from thick, radiation supported accretion discs around black holes. Numerical results are obtained for the 'extreme' discs with rsub(out) = 10/sup 3/ GMsub(BH)/c/sup 2/, the angular momentum of the black hole being Jsub(BH) = 0.998 GMsub(BH)/c. The high luminosity (L approximately 8.5 Lsub(Edd)) and substantial collimation of radiation found for these discs indicate that such discs can explain both the high luminosities of quasars and similar objects and may produce some of the observed beams and jets.

  5. Tracing Planets in Circumstellar Discs

    Directory of Open Access Journals (Sweden)

    Uribe Ana L.

    2013-04-01

    Full Text Available Planets are assumed to form in circumstellar discs around young stellar objects. The additional gravitational potential of a planet perturbs the disc and leads to characteristic structures, i.e. spiral waves and gaps, in the disc density profile. We perform a large-scale parameter study on the observability of these planet-induced structures in circumstellar discs in the (submm wavelength range for the Atacama Large (SubMillimeter Array (ALMA. On the basis of hydrodynamical and magneto-hydrodynamical simulations of star-disc-planet models we calculate the disc temperature structure and (submm images of these systems. These are used to derive simulated ALMA maps. Because appropriate objects are frequent in the Taurus-Auriga region, we focus on a distance of 140 pc and a declination of ≈ 20°. The explored range of star-disc-planet configurations consists of six hydrodynamical simulations (including magnetic fields and different planet masses, nine disc sizes with outer radii ranging from 9 AU to 225 AU, 15 total disc masses in the range between 2.67·10-7 M⊙ and 4.10·10-2 M⊙, six different central stars and two different grain size distributions, resulting in 10 000 disc models. At almost all scales and in particular down to a scale of a few AU, ALMA is able to trace disc structures induced by planet-disc interaction or the influence of magnetic fields in the wavelength range between 0.4...2.0 mm. In most cases, the optimum angular resolution is limited by the sensitivity of ALMA. However, within the range of typical masses of protoplane tary discs (0.1 M⊙...0.001 M⊙ the disc mass has a minor impact on the observability. At the distance of 140 pc it is possible to resolve discs down to 2.67·10-6 M⊙ and trace gaps in discs with 2.67·10-4 M⊙ with a signal-to-noise ratio greater than three. In general, it is more likely to trace planet-induced gaps in magneto-hydrodynamical disc models, because gaps are wider in the presence of

  6. Microstructure and tribology of carbon, nitrogen, and oxygen implanted ferrous materials

    International Nuclear Information System (INIS)

    Williamson, D.L.

    1993-01-01

    Nitrogen, carbon, and oxygen ions have been implanted into ferrous materials under unusual conditions of elevated temperatures and very high dose rates. The tribological durabilities of the resulting surfaces are examined with a special type of pin-on-disc wear test apparatus and found in most cases to be dramatically improved compared to surfaces prepared with conventional implantation conditions. Near-surface microstructures and compositions are characterized after implantation and after wear testing by backscatter Moessbauer spectroscopy, X-ray diffraction, scanning electron microscopy, and Auger electron spectroscopy. These data provide evidence for the predominant mechanisms responsible for the observed sliding wear behavior induced by each of the three species. (orig.)

  7. Association of facet tropism and progressive facet arthrosis after lumbar total disc replacement using ProDisc-L.

    Science.gov (United States)

    Shin, Myung-Hoon; Ryu, Kyeong-Sik; Hur, Jung-Woo; Kim, Jin-Sung; Park, Chun-Kun

    2013-08-01

    The purpose of this retrospective study was to examine the association of facet tropism and progressive facet arthrosis (PFA) after lumbar total disc replacement (TDR) surgery using ProDisc-L. A total of 51 segments of 42 patients who had undergone lumbar TDR using ProDisc-L between October 2003 and July 2007 and completed minimum 36-month follow-up period were retrospectively reviewed. The changes of facet arthrosis were categorized as non-PFA and PFA group. Comparison between non-PFA and PFA group was made according to age, sex, mean follow-up duration, grade of preoperative facet arthrosis, coronal and sagittal prosthetic position and degree of facet tropism. Multiple logistic regression analysis was also performed to analyze the effect of facet tropism on the progression of facet arthrosis. The mean age at the surgery was 44.43 ± 11.09 years and there were 16 males and 26 females. The mean follow-up period was 53.18 ± 15.79 months. Non-PFA group was composed of 19 levels and PFA group was composed of 32 levels. Age at surgery, sex proportion, mean follow-up period, level of implant, grade of preoperative facet arthrosis and coronal and sagittal prosthetic position were not significantly different between two groups (p = 0.264, 0.433, 0.527, 0.232, 0.926, 0.849 and 0.369, respectively). However, PFA group showed significantly higher degree of facet tropism (7.37 ± 6.46°) than that of non-PFA group (3.51 ± 3.53°) and p value was 0.008. After adjustment for age, sex and coronal and sagittal prosthetic position, multiple logistic regression analysis revealed that facet tropism of more than 5° was the only significant independent predictor of progression of facet arthrosis (odds ratio 5.39, 95 % confidence interval 1.251-19.343, p = 0.023). The data demonstrate that significant higher degree of facet tropism was seen in PFA group compared with non-PFA group and facet tropism of more than 5° had a significant association with PFA after TDR using ProDisc-L.

  8. Accretion discs around neutron stars

    International Nuclear Information System (INIS)

    Pringle, J.E.

    1982-01-01

    If the central object in the disc is a neutron star, then we do not need the disc itself to produce the X-rays. In other words, the disc structure itself is not important as long as it plays the role of depositing matter on the neutron star at a sufficient rate to produce the X-ray flux. Similarly, in the outer disc regions, the main disc luminosity comes from absorption and reradiation of X-ray photons and not from the intrinsic, viscously-produced, local energy production rate. These two points indicate why in the compact binary X-ray sources confrontation between disc theory and observations is not generally practicable. For this reason I will divide my talk into two parts: one on observational discs in which I discuss what observational evidence there is for discs in the compact X-ray sources and what the evidence can tell the theorist about disc behaviour, and the other on theoretical discs where I consider in what ways theoretical arguments can put limits or cast doubt on some of the empirical models put forward to explain the observations. (orig.)

  9. Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter

    International Nuclear Information System (INIS)

    Xiao, Liang; Shen, Jing; Tong, Jia Jie; Huang, De Sheng

    2012-01-01

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10 degree) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, X 2 = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, X 2 = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  10. Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Liang; Shen, Jing; Tong, Jia Jie [The First Hospital of China Medical University, Shenyang (China); Huang, De Sheng [College of Basic Medical Science, China Medical University, Shenyang (China)

    2012-07-15

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 {+-} 4.14 degrees. In Group C, the average ACF was 7.1 {+-} 4.52 degrees. In Group T, the average ACF was 4.4 {+-} 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 {+-} 4.59 vs. 5.1 {+-} 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF {>=} 10 degree) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, X{sup 2} = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, X{sup 2} = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  11. Lifting to cluster-tilting objects in higher cluster categories

    OpenAIRE

    Liu, Pin

    2008-01-01

    In this note, we consider the $d$-cluster-tilted algebras, the endomorphism algebras of $d$-cluster-tilting objects in $d$-cluster categories. We show that a tilting module over such an algebra lifts to a $d$-cluster-tilting object in this $d$-cluster category.

  12. Double rupture disc experience

    International Nuclear Information System (INIS)

    1979-01-01

    Result of these observations, comparisons and evaluations can be summarized in the following list of concerns regarding the use of double rupture discs coupled to the liquid space of a steam generator that is subjected to a large leak sodium water reaction event. Single rupture disc show delayed collapse characteristics in LLTR Series I and double disc assemblies are presumed to be more complex with additional delay before opening to give pressure relief. Delayed failure increases pressures in the IHTS and must be adequately covered by design requirements. With CRBR design, the first disc may fail only partially reducing the loading on the second disc with the result that relief performance may not meet requirements

  13. Fatigue and wear of metalloid-ion-implanted metals

    International Nuclear Information System (INIS)

    Hohmuth, K.; Richter, E.; Rauschenbach, B.; Blochwitz, C.

    1985-01-01

    The effect of metalloid ion implantation on the fatigue behaviour and wear of nickel and two steels has been investigated. These metals were implanted with boron, carbon and nitrogen ions at energies from 30 to 60 keV and with doses from 1 X 10 16 to 1 X 10 18 ions cm -2 at room temperature. The mechanical behaviour of fatigued nickel was studied in push-pull tests at room temperature. Wear measurements were made using a pin-and-disc technique. The surface structure, dislocation arrangement and modification of the implantation profile resulting from mechanical tests on metals which had been implanted with metalloid ions were examined using high voltage electron microscopy, transmission high energy electron diffraction, scanning electron microscopy and Auger electron spectroscopy. It is reported that nitrogen and boron ion implantation improves the fatigue lifetime, changes the number and density of the slip bands and modifies the dislocation arrangements in nickel. The cyclic deformation leads to recrystallization of the boron-ion-induced amorphous structure of nickel and to diffusion of the boron and nitrogen in the direction of the surface. The wear behaviour of steels was improved by implantation of mass-separated ions and by implantation of ions without mass separation. (Auth.)

  14. Optimal wireless receiver structure for omnidirectional inductive power transmission to biomedical implants.

    Science.gov (United States)

    Gougheri, Hesam Sadeghi; Kiani, Mehdi

    2016-08-01

    In order to achieve omnidirectional inductive power transmission to biomedical implants, the use of several orthogonal coils in the receiver side (Rx) has been proposed in the past. In this paper, the optimal Rx structure for connecting three orthogonal Rx coils and the power management is found to achieve the maximum power delivered to the load (PDL) in the presence of any Rx coil tilting. Unlike previous works, in which a separate power management has been used for each coil to deliver power to the load, different resonant Rx structures for connecting three Rx coils to a single power management are studied. In simulations, connecting three Rx coils with the diameters of 3 mm, 3.3 mm, and 3.6 mm in series and resonating them with a single capacitor at the operation frequency of 100 MHz led to the maximum PDL for large loads when the implant was tilted for 45o. This optimal Rx structure achieves higher PDL in worst-case scenarios as well as reduces the number of power managements to only one.

  15. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    International Nuclear Information System (INIS)

    Murakoshi, Sadaaki

    1986-01-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 ± 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period. (author)

  16. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    Energy Technology Data Exchange (ETDEWEB)

    Murakoshi, Sadaaki

    1986-07-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 +- 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period.

  17. [Role of different scale structures of titanium implant in the biological behaviors of human umbilical vein endothelial cells].

    Science.gov (United States)

    Liang, N W; Shi, L; Huang, Y; Deng, X L

    2017-02-18

    To study the role of different scale structure of Ti implants on the biological behaviors of human umbilical vein endothelial cell (HUVECs) and to reveal the role of material surface topographical features on peri-implant angiogenesis. Titanium (Ti) discs with different surface structures (Ti discs with smooth surface, Ti discs with nano scale structure, Ti discs with micro scale structure and Ti discs with micro/nano scale structure, named as SM-Ti, Nano-Ti, Micro-Ti and Micro/Nano-Ti, respectively) were prepared and their surface topographical features were confirmed via scanning electron microscopy (SEM) observation. HUVECs were cultured on these Ti discs. Biological outcomes of HUVECs on different surfaces were carried out, including cell adhesive capacity, proliferation, vascular endothelial growth factor (VEGF) production and intracellular expression of Ca(2+). The results of SEM images and immunofluorescence double staining of rhodamine-phalloidin and DAPI showed that compared with the SM-Ti and Nano-Ti group, the adhesive capacity and proliferation behavior of HUVECs on the surfaces of Micro-Ti and Micro/Nano-Ti was decreased. The results of culturing HUVECs on different groups of Ti discs after 24 hours showed that the cells number grew from (18±4) to (42±6)/ vision on SM-Ti, (28±6) to (52±10)/vision on Nano-Ti, (20±4) to (21±6)/vision on Micro-Ti and (16±4) to (18±6)/vision on Micro/Nano-Ti. Moreover, compared with the adhesion and proliferation of HUVECs on SM-Ti group and Nano-Ti, the adhesion and proliferation of HUVECs on Micro-Ti group and Micro/Nano-Ti group was significantly reduced (PMicro-Ti and Micro/Nano-Ti were (690±35) ng/L, (560±20) ng/L, (474±43) ng/L and (517±29) ng/L, respectively. Moreover, compared with the VEGF production of HUVECs on SM-Ti group, the VEGF production of HUVECs on Micro-Ti group and Micro/Nano-Ti group was significantly reduced (PMicro-Ti and Micro/Nano-Ti was significantly higher than that on the surface of

  18. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  19. Radially truncated galactic discs

    NARCIS (Netherlands)

    Grijs, R. de; Kregel, M.; Wesson, K H

    2000-01-01

    Abstract: We present the first results of a systematic analysis of radially truncatedexponential discs for four galaxies of a sample of disc-dominated edge-onspiral galaxies. Edge-on galaxies are very useful for the study of truncatedgalactic discs, since we can follow their light distributions out

  20. Introducer curving technique for the prevention of tilting of transfemoral Günther Tulip inferior vena cava filter.

    Science.gov (United States)

    Xiao, Liang; Huang, De-sheng; Shen, Jing; Tong, Jia-jie

    2012-01-01

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ(2) = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ(2) = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  1. Optic disc oedema

    DEFF Research Database (Denmark)

    Nielsen, Marianne Kromann; Hamann, Steffen

    2014-01-01

    Optic disc oedema describes the nonspecific, localized swelling of the optic nerve head regardless of aetiology. Therefore, differentiating among the various aetiologies depends on a thorough history and knowledge of the clinical characteristics of the underlying conditions. Papilloedema strictly...... refers to optic disc oedema as a consequence of elevated intracranial pressure. It is usually a bilateral condition and visual function is preserved until late. Optic disc oedema caused by an anterior optic neuropathy is usually unilateral and accompanied by the loss of visual function....

  2. Cluster analysis as a method for determining size ranges for spinal implants: disc lumbar replacement prosthesis dimensions from magnetic resonance images.

    Science.gov (United States)

    Lei, Dang; Holder, Roger L; Smith, Francis W; Wardlaw, Douglas; Hukins, David W L

    2006-12-01

    Statistical analysis of clinical radiologic data. To develop an objective method for finding the number of sizes for a lumbar disc replacement. Cluster analysis is a well-established technique for sorting observations into clusters so that the "similarity level" is maximal if they belong to the same cluster and minimal otherwise. Magnetic resonance scans from 69 patients, with no abnormal discs, yielded 206 sagittal and transverse images of 206 discs (levels L3-L4-L5-S1). Anteroposterior and lateral dimensions were measured from vertebral margins on transverse images; disc heights were measured from sagittal images. Hierarchical cluster analysis was performed to determine the number of clusters followed by nonhierarchical (K-means) cluster analysis. Discriminant analysis was used to determine how well the clusters could be used to classify an observation. The most successful method of clustering the data involved the following parameters: anteroposterior dimension; lateral dimension (both were the mean of results from the superior and inferior margins of a vertebral body, measured on transverse images); and maximum disc height (from a midsagittal image). These were grouped into 7 clusters so that a discriminant analysis was capable of correctly classifying 97.1% of the observations. The mean and standard deviations for the parameter values in each cluster were determined. Cluster analysis has been successfully used to find the dimensions of the minimum number of prosthesis sizes required to replace L3-L4 to L5-S1 discs; the range of sizes would enable them to be used at higher lumbar levels in some patients.

  3. Optic flow induced self-tilt perception

    NARCIS (Netherlands)

    Bos, J.E.

    2008-01-01

    Roll optic flow induces illusory self-tilt in humans. As far as the mechanism underlying this visual-vestibular interaction is understood, larger angles of self-tilt are predicted than observed. It is hypothesized that the discrepancy can be explained by idiotropic (i.e., referring to a personal

  4. Spheromak tilting and its stability control

    International Nuclear Information System (INIS)

    Hayashi, T.; Sato, T.

    1983-01-01

    Spheromak tilting instability was studied. A numerical technique to create a rather arbitrarily-shaped spheromak like the one with a flux hole was investigated. The dynamics governing the tilting instability, namely, the influence of the magnetic index, the toroidal current (q-profile) and the resistivity upon the tilting growth rate, and the roles of magnetc reconnection upon the nonlinear development were studied. The best way to control the tilting instability was invented. The stabilizing effects of the vertical wall, the isolated conducting cylindrical belt, and the horizontal wall were studied. Central pole stabilization was also investigated. The influence of the wall condition, namely, whether the wall acted as a flux conserver in the spheromak creation stage or not is discussed. The present study has shown that the three- dimensional simulation is indeed useful and practical in not only studying the underlying physics but also finding a stabilization technique of spheromaks. (Kato, T.)

  5. Backscattered electron imaging: The role in calcified tissue and implant analysis

    International Nuclear Information System (INIS)

    Bloebaum, R.D.; Bachus, K.N.; Boyce, T.M.

    1990-01-01

    The working distance and tilt studies helped to clarify the influences of specimen variability when the BSE mode is used in calcified tissue research. This work has shown that the BSEPs of cortical bone may be accurately maintained within 2 percent error over a 10 degree range of tilt, or 300 microns working distance variation. If future bone and implant investigators wish to conduct accurate, quantitative mineral microanalysis in bone, then standard grinding and polishing techniques should be adequate if calibration procedures are developed. The BSEP characteristics of the pure metals make them suitable to be used for calibrating the BSE signal. BSE analysis, with correlated biomechanical studies, will lead us to a better understanding of the relationships between structure, function, and mineral content in bone. On-line BSEP analysis techniques will expand our understanding of the mineralization events in bone which are associated with aging, weightlessness, pharmaceutical therapies, and the presence of biomaterials. The future of the BSE imaging technology and the contributions to be made in understanding the histometry, biomechanics and mineral content of bone as well as bone's response to implant materials has just begun to unfold. 74 references

  6. Proto-planetary disc evolution and dispersal

    Science.gov (United States)

    Rosotti, Giovanni Pietro

    2015-05-01

    Planets form from gas and dust discs in orbit around young stars. The timescale for planet formation is constrained by the lifetime of these discs. The properties of the formed planetary systems depend thus on the evolution and final dispersal of the discs, which is the main topic of this thesis. Observations reveal the existence of a class of discs called "transitional", which lack dust in their inner regions. They are thought to be the last stage before the complete disc dispersal, and hence they may provide the key to understanding the mechanisms behind disc evolution. X-ray photoevaporation and planet formation have been studied as possible physical mechanisms responsible for the final dispersal of discs. However up to now, these two phenomena have been studied separately, neglecting any possible feedback or interaction. In this thesis we have investigated what is the interplay between these two processes. We show that the presence of a giant planet in a photo-evaporating disc can significantly shorten its lifetime, by cutting the inner regions from the mass reservoir in the exterior of the disc. This mechanism produces transition discs that for a given mass accretion rate have larger holes than in models considering only X-ray photo-evaporation, constituting a possible route to the formation of accreting transition discs with large holes. These discs are found in observations and still constitute a puzzle for the theory. Inclusion of the phenomenon called "thermal sweeping", a violent instability that can destroy a whole disc in as little as 10 4 years, shows that the outer disc left can be very short-lived (depending on the X-ray luminosity of the star), possibly explaining why very few non accreting transition discs are observed. However the mechanism does not seem to be efficient enough to reconcile with observations. In this thesis we also show that X-ray photo-evaporation naturally explains the observed correlation between stellar masses and accretion

  7. Damage accumulation in nitrogen implanted 6H-SiC: Dependence on the direction of ion incidence and on the ion fluence

    International Nuclear Information System (INIS)

    Zolnai, Z.; Ster, A.; Khanh, N. Q.; Battistig, G.; Lohner, T.; Gyulai, J.; Kotai, E.; Posselt, M.

    2007-01-01

    The influence of crystallographic orientation and ion fluence on the shape of damage distributions induced by 500 keV N + implantation at room temperature into 6H-SiC is investigated. The irradiation was performed at different tilt angles between 0 degree sign and 4 degree sign with respect to the crystallographic axis in order to consider the whole range of beam alignment from channeling to random conditions. The applied implantation fluence range was 2.5x10 14 -3x10 15 cm -2 . A special analytical method, 3.55 MeV 4 He + ion backscattering analysis in combination with channeling technique (BS/C), was employed to measure the disorder accumulation simultaneously in the Si and C sublattices of SiC with good depth resolution. For correct energy to depth conversion in the BS/C spectra, the average electronic energy loss per analyzing He ion for the axial channeling direction was determined. It was found that the tilt angle of nitrogen implantation has strong influence on the shape of the induced disorder profiles. Significantly lower disorder was found for channeling than for random irradiation. Computer simulation of the measured BS/C spectra showed the presence of a simple defect structure in weakly damaged samples and suggested the formation of a complex disorder state for higher disorder levels. Full-cascade atomistic computer simulation of the ion implantation process was performed to explain the differences in disorder accumulation on the Si and C sublattices. The damage buildup mechanism was interpreted with the direct-impact, defect-stimulated amorphization model in order to understand damage formation and to describe the composition of structural disorder versus the ion fluence and the implantation tilt angle

  8. Mapping of moveout in tilted transversely isotropic media

    KAUST Repository

    Stovas, A.; Alkhalifah, Tariq Ali

    2013-01-01

    The computation of traveltimes in a transverse isotropic medium with a tilted symmetry axis tilted transversely isotropic is very important both for modelling and inversion. We develop a simple analytical procedure to map the traveltime function from a transverse isotropic medium with a vertical symmetry axis (vertical transversely isotropic) to a tilted transversely isotropic medium by applying point-by-point mapping of the traveltime function. This approach can be used for kinematic modelling and inversion in layered tilted transversely isotropic media. © 2013 European Association of Geoscientists & Engineers.

  9. Mapping of moveout in tilted transversely isotropic media

    KAUST Repository

    Stovas, A.

    2013-09-09

    The computation of traveltimes in a transverse isotropic medium with a tilted symmetry axis tilted transversely isotropic is very important both for modelling and inversion. We develop a simple analytical procedure to map the traveltime function from a transverse isotropic medium with a vertical symmetry axis (vertical transversely isotropic) to a tilted transversely isotropic medium by applying point-by-point mapping of the traveltime function. This approach can be used for kinematic modelling and inversion in layered tilted transversely isotropic media. © 2013 European Association of Geoscientists & Engineers.

  10. CT discography for cervical soft disc hernia

    Energy Technology Data Exchange (ETDEWEB)

    Iwasa, Kenichi; Mizutani, Shigeru; Morimoto, Hiroyuki; Yamada, Hidehito; Iwasa, Satoru

    1985-03-01

    In this study the effectiveness of computed tomographic discography (CTD) in diagnosing cervical soft disc hernia was evaluated. Twenty-five intervertebral discs of 15 cases with cervical soft disc hernia were examined with a discography and then a CT scan. Results of the CT scan were as follows: three discs were protruded, 12 discs were prolapsed, 6 discs were extruded, and 4 discs were sequestrated. The findings were helpful in determining the location of soft disc hernias between the median and posterolateral discs. They were also valuable in classifying types of hernias and surgical approaches.

  11. Magnetic moment of $^{17}$Ne using beta -NMR and tilted foil polarization

    CERN Document Server

    Baby, L T; Hass, M; Haas, H; Weissman, L; Brown, B A

    2004-01-01

    We report on the measurement of the magnetic moment of the ground state of /sup 17/Ne. Radioactive /sup 17/Ne nuclei were delivered from the high resolution mass separator at ISOLDE onto a high voltage platform at -200 kV and were polarized using the tilted foil polarization method. The polarized nuclei were implanted into a Pt stopper situated in a liquid-helium cooled beta -NMR apparatus and the asymmetry destruction of the ensuing beta rays was monitored as a function of the rf frequency applied to the polarized nuclei. The measured value of mu = 0.74 +or- 0.03 affirms the nu p/sub 1/2//sup - / nature of the ground state of /sup 17/Ne and is compared to shell model calculations. (10 refs).

  12. CT discography for cervical soft disc hernia

    International Nuclear Information System (INIS)

    Iwasa, Kenichi; Mizutani, Shigeru; Morimoto, Hiroyuki; Yamada, Hidehito; Iwasa, Satoru

    1985-01-01

    In this study the effectiveness of computed tomographic discography (CTD) in diagnosing cervical soft disc hernia was evaluated. Twenty-five interververtebral discs of 15 cases with cervical soft disc hernia were examined with a discography and then a CT scan. Results of the CT scan were as follows: three discs were protruded, 12 discs were prolapsed, 6 discs were extruded, and 4 discs were sequestrated. The findings were helpful in determining the location of soft disc hernians between the median and posterolateral discs. They were also valuable in classifying types of hernians and surgical aproaches. (author)

  13. Bacteremia following dental implant surgery: preliminary results.

    Science.gov (United States)

    Bölükbaşı, Nilüfer; Özdemir, Tayfun; Öksüz, Lütfiye; Gürler, Nezahat

    2012-01-01

    The aims of this study were to investigate the incidence of bacteremia, bacteriology and antibiotic susceptibility against to causative bacteria associated with dental implant installation. 30 generally healthy patients were enrolled in this study. Blood samples were collected at baseline and at 30 minutes after dental implant installation and 24 hours after dental implant surgery. Blood samples were cultured in a BACTEC system. The isolated bacteria were identified using conventional methods. Antimicrobial sensitivity tests were performed by disc diffusion. No bacteria were isolated at the baseline and 24 hours after surgery, whereas the prevalence of bacteremia at 30 minutes after dental implant installation was 23%. The isolated bacteria species were Staphylococcus epidermidis, Eubacterium spp., Corynebacterium spp. and Streptococcus viridans. The Staphylococcus epidermidis, which was isolated in three patients, was found to be resistant to penicillin which is first choice of many clinicians. Our findings suggest that installation of dental implants can produce bacteremia. Within the limitations of this study, it can be speculated that the resistance of antibiotics may compromise the routine prophylaxis against infective endocarditis. Therefore use of blood cultures and antibiograms may be suggested in risky patients. The outcome of the present study should be verified using a larger patient group with varying conditions.

  14. Transient cardio-respiratory responses to visually induced tilt illusions

    Science.gov (United States)

    Wood, S. J.; Ramsdell, C. D.; Mullen, T. J.; Oman, C. M.; Harm, D. L.; Paloski, W. H.

    2000-01-01

    Although the orthostatic cardio-respiratory response is primarily mediated by the baroreflex, studies have shown that vestibular cues also contribute in both humans and animals. We have demonstrated a visually mediated response to illusory tilt in some human subjects. Blood pressure, heart and respiration rate, and lung volume were monitored in 16 supine human subjects during two types of visual stimulation, and compared with responses to real passive whole body tilt from supine to head 80 degrees upright. Visual tilt stimuli consisted of either a static scene from an overhead mirror or constant velocity scene motion along different body axes generated by an ultra-wide dome projection system. Visual vertical cues were initially aligned with the longitudinal body axis. Subjective tilt and self-motion were reported verbally. Although significant changes in cardio-respiratory parameters to illusory tilts could not be demonstrated for the entire group, several subjects showed significant transient decreases in mean blood pressure resembling their initial response to passive head-up tilt. Changes in pulse pressure and a slight elevation in heart rate were noted. These transient responses are consistent with the hypothesis that visual-vestibular input contributes to the initial cardiovascular adjustment to a change in posture in humans. On average the static scene elicited perceived tilt without rotation. Dome scene pitch and yaw elicited perceived tilt and rotation, and dome roll motion elicited perceived rotation without tilt. A significant correlation between the magnitude of physiological and subjective reports could not be demonstrated.

  15. Gravitating discs around black holes

    International Nuclear Information System (INIS)

    Karas, V; Hure, J-M; Semerak, O

    2004-01-01

    Fluid discs and tori around black holes are discussed within different approaches and with the emphasis on the role of disc gravity. First reviewed are the prospects of investigating the gravitational field of a black hole-disc system using analytical solutions of stationary, axially symmetric Einstein equations. Then, more detailed considerations are focused to the middle and outer parts of extended disc-like configurations where relativistic effects are small and the Newtonian description is adequate. Within general relativity, only a static case has been analysed in detail. Results are often very inspiring. However, simplifying assumptions must be imposed: ad hoc profiles of the disc density are commonly assumed and the effects of frame-dragging are completely lacking. Astrophysical discs (e.g. accretion discs in active galactic nuclei) typically extend far beyond the relativistic domain and are fairly diluted. However, self-gravity is still essential for their structure and evolution, as well as for their radiation emission and the impact on the surrounding environment. For example, a nuclear star cluster in a galactic centre may bear various imprints of mutual star-disc interactions, which can be recognized in observational properties, such as the relation between the central mass and stellar velocity dispersion. (topical review)

  16. Motion perception during tilt and translation after space flight

    Science.gov (United States)

    Clément, Gilles; Wood, Scott J.

    2013-11-01

    Preliminary results of an ongoing study examining the effects of space flight on astronauts' motion perception induced by independent tilt and translation motions are presented. This experiment used a sled and a variable radius centrifuge that translated the subjects forward-backward or laterally, and simultaneously tilted them in pitch or roll, respectively. Tests were performed on the ground prior to and immediately after landing. The astronauts were asked to report about their perceived motion in response to different combinations of body tilt and translation in darkness. Their ability to manually control their own orientation was also evaluated using a joystick with which they nulled out the perceived tilt while the sled and centrifuge were in motion. Preliminary results confirm that the magnitude of perceived tilt increased during static tilt in roll after space flight. A deterioration in the crewmember to control tilt using non-visual inertial cues was also observed post-flight. However, the use of a tactile prosthesis indicating the direction of down on the subject's trunk improved manual control performance both before and after space flight.

  17. Mechanical valve at pulmonary site in adult TOF & absent pulmonary valve

    Directory of Open Access Journals (Sweden)

    Aayush Goyal

    2017-09-01

    Full Text Available Absent pulmonary valve syndrome (APVS is a rare congenital heart disease. Tetralogy of Fallot (TOF with APVS is a rare variation of TOF. These patients are commonly cyanotic at birth. Respiratory complaints predominate due to airway compression by dilated pulmonary arteries. Commonest age of presentation is infancy with anecdotal adult case-reports. Surgical treatment requires establishing unobstructed competent right ventricular outflow tract (RVOT often with monocusp or conduits. We present a novel technique of rendering RVOT competent by implanting a tilting disc mechanical prosthesis in a rare adult TOF with APVS.

  18. Perception of self-tilt in a true and illusory vertical plane

    Science.gov (United States)

    Groen, Eric L.; Jenkin, Heather L.; Howard, Ian P.; Oman, C. M. (Principal Investigator)

    2002-01-01

    A tilted furnished room can induce strong visual reorientation illusions in stationary subjects. Supine subjects may perceive themselves upright when the room is tilted 90 degrees so that the visual polarity axis is kept aligned with the subject. This 'upright illusion' was used to induce roll tilt in a truly horizontal, but perceptually vertical, plane. A semistatic tilt profile was applied, in which the tilt angle gradually changed from 0 degrees to 90 degrees, and vice versa. This method produced larger illusory self-tilt than usually found with static tilt of a visual scene. Ten subjects indicated self-tilt by setting a tactile rod to perceived vertical. Six of them experienced the upright illusion and indicated illusory self-tilt with an average gain of about 0.5. This value is smaller than with true self-tilt (0.8), but comparable to the gain of visually induced self-tilt in erect subjects. Apparently, the contribution of nonvisual cues to gravity was independent of the subject's orientation to gravity itself. It therefore seems that the gain of visually induced self-tilt is smaller because of lacking, rather than conflicting, nonvisual cues. A vector analysis is used to discuss the results in terms of relative sensory weightings.

  19. Suppression of threshold voltage variability in MOSFETs by adjustment of ion implantation parameters

    Science.gov (United States)

    Park, Jae Hyun; Chang, Tae-sig; Kim, Minsuk; Woo, Sola; Kim, Sangsig

    2018-01-01

    In this study, we investigate threshold voltage (VTH) variability of metal-oxide-semiconductor field-effect transistors induced by random dopant fluctuation (RDF). Our simulation work demonstrates not only the influence of the implantation parameters such as its dose, tilt angle, energy, and rotation angle on the RDF-induced VTH variability, but also the solution to reduce the effect of this variability. By adjusting the ion implantation parameters, the 3σ (VTH) is reduced from 43.8 mV to 28.9 mV. This 34% reduction is significant, considering that our technique is very cost effective and facilitates easy fabrication, increasing availability.

  20. Vortex trapping by tilted columnar defects

    International Nuclear Information System (INIS)

    Baladie, I.; Buzdin, A.

    2000-01-01

    The irradiation of high-T c superconductors by inclined heavy-ion beam can create columnar defects (CD's) practically at any angle towards the crystal c axis. We calculate the energy of a tilted vortex trapped on an inclined columnar defect within the framework of an electromagnetic model. Under a weak perpendicular magnetic field, and if the CD radius is larger than the superconducting coherence length, vortices always prefer to be on a tilted CD than to be aligned along the external field. We calculate also the interaction energy between two tilted vortices and find that large attractive regions appear. In particular, in the plane defined by c axis and the CD axis, tilted vortices attract each other at long distances, leading to the formation of vortex chains. The equilibrium distance between vortices in a chain is of the order of the magnitude of the in-plane London penetration depth. The existence of the inclined trapped vortices could be revealed by torque measurements, and could also lead to the anisotropy of the in-plane resistivity and the critical current

  1. Behavior of Tilted Angle Shear Connectors

    Science.gov (United States)

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N. H.

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type. PMID:26642193

  2. Behavior of Tilted Angle Shear Connectors.

    Directory of Open Access Journals (Sweden)

    Koosha Khorramian

    Full Text Available According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.

  3. Fas ligand exists on intervertebral disc cells: a potential molecular mechanism for immune privilege of the disc.

    Science.gov (United States)

    Takada, Toru; Nishida, Kotaro; Doita, Minoru; Kurosaka, Masahiro

    2002-07-15

    Rat and human intervertebral disc specimens were examined immunohistochemically. Reverse transcription polymerase chain reaction (RT-PCR) analysis was also performed on rat disc tissue to demonstrate the existence of Fas ligand. To clarify the existence of Fas ligand on intact intervertebral disc cells. The nucleus pulposus has been reported to be an immune-privileged site. The immune-privileged characteristic in other tissues such as the retina and testis has been attributed to the local expression of Fas ligand, which acts by inducing apoptosis of invading Fas-positive T-cells. The existence of Fas ligand in normal disc cells has not yet been addressed. Skeletally mature SD male rats were killed, and the coccygeal discs were harvested. Human disc specimens were obtained from idiopathic scoliosis patients during surgical procedures. Immunohistochemical staining for Fas ligand was performed for cross-sections of the discs by standard procedures. Reverse transcription polymerase chain reaction analysis was also carried out to demonstrate Fas ligand mRNA expression on rat intervertebral discs. Testes of the rats were used for positive controls, and muscles were used for negative controls. The sections were observed by light microscopy. The nucleus pulposus cells exhibited intense positive immune staining for Fas ligand. The outer anulus fibrosus cells and notochordal cells exhibited little immunopositivity. The positive controls exhibited positive immune staining, and the negative control showed no immunopositivity. The result of RT-PCR confirmed the existence of Fas ligand in disc cells. The human nucleus pulposus cells showed a similar predilection to rat disc cells. We demonstrated the existence of Fas ligand on disc cells, which should play a key role in the potential molecular mechanism to maintain immune privilege of the disc. Immune privilege and Fas ligand expression of the intervertebral disc may provide a new insight for basic science research as well as

  4. Evidence for cell-replacement repair of X-ray-induced teratogenic damage in male genital imaginal discs of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Fukunaga, Akihiro; Kondo, Sohei

    1985-01-01

    Male genital imaginal discs from old (late-third-instar) larvae of Drosophila that had been X-irradiated with appropriate doses developed into severely damaged adult genitalia when implanted into old larvae, but they developed into completely normal adult genitalia when transplanted into 2-day-younger larvae. Complete repair of X-ray-induced teratogenic damage in the genital discs on transplantation into young host larvae was similar in the wild-type and mei-9sup(a) strains. The results are discussed in relation to the hypothesis that repair of X-ray-induced teratogenic damage depends not on DNA repair but on replacement of damage-bearing primordial cells by healthy ones after suicidal elimination of the former. (Auth.)

  5. Lake-tilting investigations in southern Sweden

    International Nuclear Information System (INIS)

    Paasse, T.

    1996-04-01

    The main aim of lake-tilting investigations is to determine the course of the glacio-isostatic uplift, i.e. to find a formula for the uplift. Besides the lake-tilting graphs, knowledge of the recent relative uplift and the gradient of some marine shorelines are used for solving this problem. This paper summarizes four investigations. 23 refs, 10 figs

  6. Characterization and human gingival fibroblasts biocompatibility of hydroxyapatite/PMMA nanocomposites for provisional dental implant restoration

    Science.gov (United States)

    Zhang, Jingchao; Liao, Juan; Mo, Anchun; Li, Yubao; Li, Jidong; Wang, Xuejiang

    2008-11-01

    The aim of this study was to determine nHA/PMMA composites (H/P) in an optimal ratio with improved cytocompatibility as well as valid physical properties for provisional dental implant restoration. 20 wt.%, 30 wt.%, 40 wt.% and 50 wt.% H/P were developed and characterized using XPS, bending strength test and SEM. Human gingival fibroblasts cultured in extracts or directly on sample discs were investigated by fluorescent staining and MTT assay. Chemical integration in nHA/PMMA interface was indicated by XPS. Typical fusiform cells with adhesion spots were detected on H/P discs. MTT results also indicated higher cell viability in 30 wt.% and 40 wt.% H/P discs ( P provisional fixed crowns (PFC) is 0.4:1.

  7. Retina image–based optic disc segmentation

    Directory of Open Access Journals (Sweden)

    Ching-Lin Wang

    2016-05-01

    Full Text Available The change of optic disc can be used to diagnose many eye diseases, such as glaucoma, diabetic retinopathy and macular degeneration. Moreover, retinal blood vessel pattern is unique for human beings even for identical twins. It is a highly stable pattern in biometric identification. Since optic disc is the beginning of the optic nerve and main blood vessels in retina, it can be used as a reference point of identification. Therefore, optic disc segmentation is an important technique for developing a human identity recognition system and eye disease diagnostic system. This article hence presents an optic disc segmentation method to extract the optic disc from a retina image. The experimental results show that the optic disc segmentation method can give impressive results in segmenting the optic disc from a retina image.

  8. Prognosis of intervertebral disc loss from diagnosis of degenerative disc disease

    Science.gov (United States)

    Li, S.; Lin, A.; Tay, K.; Romano, W.; Osman, Said

    2015-03-01

    Degenerative Disc Disease (DDD) is one of the most common causes of low back pain, and is a major factor in limiting the quality of life of an individual usually as they enter older stages of life, the disc degeneration reduces the shock absorption available which in turn causes pain. Disc loss is one of the central processes in the pathogenesis of DDD. In this study, we investigated whether the image texture features quantified from magnetic resonance imaging (MRI) could be appropriate markers for diagnosis of DDD and prognosis of inter-vertebral disc loss. The main objective is to use simple image based biomarkers to perform prognosis of spinal diseases using non-invasive procedures. Our results from 65 subjects proved the higher success rates of the combination marker compared to the individual markers and in the future, we will extend the study to other spine regions to allow prognosis and diagnosis of DDD for a wider region.

  9. Physiological pattern of lumbar disc height

    International Nuclear Information System (INIS)

    Biggemann, M.; Frobin, W.; Brinckmann, P.

    1997-01-01

    Purpose of this study is to present a new method of quantifying objectively the height of all discs in lateral radiographs of the lumbar spine and of analysing the normal craniocaudal sequence pattern of lumbar disc heights. Methods: The new parameter is the ventrally measured disc height corrected for the dependence on the angle of lordosis by normalisation to mean angles observed in the erect posture of healthy persons. To eliminate radiographic magnification, the corrected ventral height is related to the mean depth of the cranially adjoining vertebra. In this manner lumbar disc heights were objectively measured in young, mature and healthy persons (146 males and 65 females). The craniocaudal sequence pattern was analysed by mean values from all persons and by height differences of adjoining discs in each individual lumbar spine. Results: Mean normative values demonstrated an increase in disc height between L1/L2 and L4/L5 and a constant or decreasing disc height between L4/L5 and L5/S1. However, this 'physiological sequence of disc height in the statistical mean' was observed in only 36% of normal males and 55% of normal females. Conclusion: The radiological pattern of the 'physiological sequence of lumbar disc height' leads to a relevant portion of false positive pathological results especially at L4/L5. An increase of disc height from L4/L5 to L5/S1 may be normal. The recognition of decreased disc height should be based on an abrupt change in the heights of adjoining discs and not on a deviation from a craniocaudal sequence pattern. (orig.) [de

  10. CT morphometry of adult thoracic intervertebral discs.

    Science.gov (United States)

    Fletcher, Justin G R; Stringer, Mark D; Briggs, Christopher A; Davies, Tilman M; Woodley, Stephanie J

    2015-10-01

    Despite being commonly affected by degenerative disorders, there are few data on normal thoracic intervertebral disc dimensions. A morphometric analysis of adult thoracic intervertebral discs was, therefore, undertaken. Archival computed tomography scans of 128 recently deceased individuals (70 males, 58 females, 20-79 years) with no known spinal pathology were analysed to determine thoracic disc morphometry and variations with disc level, sex and age. Reliability was assessed by intraclass correlation coefficients (ICCs). Anterior and posterior intervertebral disc heights and axial dimensions were significantly greater in men (anterior disc height 4.0±1.4 vs 3.6±1.3 mm; posterior disc height 3.6±0.90 vs 3.4±0.93 mm; p<0.01). Disc heights and axial dimensions at T4-5 were similar or smaller than at T2-3, but thereafter increased caudally (mean anterior disc height T4-5 and T10-11, 2.7±0.7 and 5.4±1.2 mm, respectively, in men; 2.6±0.8 and 5.1±1.3 mm, respectively, in women; p<0.05). Except at T2-3, anterior disc height decreased with advancing age and anteroposterior and transverse disc dimensions increased; posterior and middle disc heights and indices of disc shape showed no consistent statistically significant changes. Most parameters showed substantial to almost perfect agreement for intra- and inter-rater reliability. Thoracic disc morphometry varies significantly and consistently with disc level, sex and age. This study provides unique reference data on adult thoracic intervertebral disc morphometry, which may be useful when interpreting pathological changes and for future biomechanical and functional studies.

  11. Surface engineering by ion implantation

    International Nuclear Information System (INIS)

    Nielsen, Bjarne Roger

    1995-01-01

    Awidespread commercial applica tion iof particle accelerators is for ion implantation. Accelerator beams are used for ion implantation into metals, alloying a thin surface layer with foreign atoms to concentrations impossible to achieve by thermal processes, making for dramatic improvements in hardness and in resistance to wear and corrosion. Traditional hardening processes require high temperatures causing deformation; ion implantation on the other hand is a ''cold process'', treating the finished product. The ionimplanted layer is integrated in the substrate, avoiding the risk of cracking and delamination from normal coating processes. Surface properties may be ''engineered'' independently of those of the bulk material; the process does not use environmentally hazardous materials such as chromium in the surface coating. The typical implantation dose required for the optimum surface properties of metals is around 2 x 10 17 ion/cm 2 , a hundred times the typical doses for semiconductor processing. When surface areas of more than a few square centimetres have to be treated, the implanter must therefore be able to produce high beam currents (5 to 10 mA) to obtain an acceptable treatment time. Ion species used include nitrogen, boron, carbon, titanium, chromium and tantalum, and beam energies range from 50 to 200 keV. Since most components are three dimensional, it must be possible to rotate and tilt them in the beam, and control beam position over a large area. Examples of industrial applications are: - surface treatment of prostheses (hip and knee joints) to reduce wear of the moving parts, using biocompatible materials; - ion implantation into high speed ball bearings to protect against the aqueous corrosion in jet engines (important for service helicopters on oil rigs); - hardening of metal forming and cutting tools; - reduction of corrosive wear of plastic moulding tools, which are expensive to produce

  12. Study of a Car Body Tilting System Using a Variable Link Mechanism: Fundamental Characteristics of Pendulum Motion and Strategy for Perfect Tilting

    Science.gov (United States)

    Yoshida, Hidehisa; Nagai, Masao

    This paper analyzes the fundamental dynamic characteristics of a tilting railway vehicle using a variable link mechanism for compensating both the lateral acceleration experienced by passengers and the wheel load imbalance between the inner and outer rails. The geometric relations between the center of rotation, the center of gravity, and the positions of all four links of the tilting system are analyzed. Then, equations of the pendulum motions of the railway vehicle body with a four-link mechanism are derived. A theoretically discussion is given on the geometrical shapes employed in the link mechanism that can simultaneously provide zero lateral acceleration and zero wheel load fluctuation. Then, the perfect tilting condition, which is the control target of the feedforward tilting control, is derived from the linear equation of tilting motion.

  13. Source to Accretion Disk Tilt

    OpenAIRE

    Montgomery, M. M.; Martin, E. L.

    2010-01-01

    Many different system types retrogradely precess, and retrograde precession could be from a tidal torque by the secondary on a misaligned accretion disk. However, a source to cause and maintain disk tilt is unknown. In this work, we show that accretion disks can tilt due to a force called lift. Lift results from differing gas stream supersonic speeds over and under an accretion disk. Because lift acts at the disk's center of pressure, a torque is applied around a rotation axis passing through...

  14. Optimal tilt-angles for solar collectors used in China

    International Nuclear Information System (INIS)

    Tang Runsheng; Wu Tong

    2004-01-01

    A reasonable estimation of the optimal tilt angle of a fixed collector for maximizing its energy collection must be done based on the monthly global and diffuse radiation on a horizontal surface. However, the monthly diffuse radiation is not always available in many places. In this paper, a simple mathematical procedure for the estimation of the optimal tilt angle of a collector is presented based on the monthly horizontal radiation. A comparison of the optimal tilt angles of collectors obtained from expected monthly diffuse radiation and that from the actual monthly diffuse radiation showed that this method gives a good estimation of the optimal tilt angle, except for places with a considerably lower clearness index. A contour map of the optimal tilt angle of the south-facing collectors used for the entire year in China is also outlined, based on monthly horizontal radiation of 152 places around the country, combing the optimal tilt angle of another 30 cities based on the actual monthly diffuse radiation

  15. LONG-TERM MEASUREMENTS OF SUNSPOT MAGNETIC TILT ANGLES

    Energy Technology Data Exchange (ETDEWEB)

    Li Jing [Department of Earth and Space Sciences, University of California at Los Angeles, Los Angeles, CA 90095-1567 (United States); Ulrich, Roger K., E-mail: jli@igpp.ucla.edu [Department of Physics and Astronomy, University of California at Los Angeles, Los Angeles, CA 90095-1567 (United States)

    2012-10-20

    Tilt angles of close to 30,600 sunspots are determined using Mount Wilson daily averaged magnetograms taken from 1974 to 2012, and SOHO/MDI magnetograms taken from 1996 to 2010. Within a cycle, more than 90% of sunspots have a normal polarity alignment along the east-west direction following Hale's law. The median tilts increase with increasing latitude (Joy's law) at a rate of {approx}0.{sup 0}5 per degree of latitude. Tilt angles of spots appear largely invariant with respect to time at a given latitude, but they decrease by {approx}0.{sup 0}9 per year on average, a trend that largely reflects Joy's law following the butterfly diagram. We find an asymmetry between the hemispheres in the mean tilt angles. On average, the tilts are greater in the Southern than in the Northern Hemisphere for all latitude zones, and the differences increase with increasing latitude.

  16. Persistent axial neck pain after cervical disc arthroplasty: a radiographic analysis.

    Science.gov (United States)

    Wagner, Scott C; Formby, Peter M; Kang, Daniel G; Van Blarcum, Gregory S; Cody, John P; Tracey, Robert W; Lehman, Ronald A

    2016-07-01

    There is very little literature examining optimal radiographic parameters for placement of cervical disc arthroplasty (CDA), nor is there substantial evidence evaluating the relationship between persistent postoperative neck pain and radiographic outcomes. We set out to perform a single-center evaluation of the radiographic outcomes, including associated complications, of CDA. This is a retrospective review. Two hundred eighty-five consecutive patients undergoing CDA were included in the review. The outcome measures were radiological parameters (preoperative facet arthrosis, disc height, CDA placement in sagittal and coronal planes, heterotopic ossification [HO] formation, etc.) and patient outcomes (persistent pain, recurrent pain, new-onset pain, etc.). We performed a retrospective review of all patients from a single military tertiary medical center from August 2008 to August 2012 undergoing CDA. Preoperative, immediate postoperative, and final follow-up films were evaluated. The clinical outcomes and complications associated with the procedure were also examined. The average radiographic follow-up was 13.5 months and the rate of persistent axial neck pain was 17.2%. For patients with persistent neck pain, the rate of HO formation per level studied was 22.6%, whereas the rate was significantly lower for patients without neck pain (11.7%, p=.03). There was no significant association between the severity of HO and the presence of neck pain. Patients with a preoperative diagnosis of cervicalgia, compared to those without cervicalgia, were significantly more likely to experience continued neck pain postoperatively (28.6% vs. 13.1%, p=.01). There were no differences in preoperative facet arthrosis, pre- or postoperative disc height, segmental range of motion, or placement of the device relative to the posterior edge of the vertebral body.However, patients with implants more centered between the uncovertebral joints were more likely to experience posterior neck pain

  17. Surface modification of austenitic stainless steel by titanium ion implantation

    International Nuclear Information System (INIS)

    Evans, P.J.; Hyvarinen, J.; Samandi, M.

    1995-01-01

    The wear properties of AISI 316 austenitic stainless steel implanted with Ti were investigated for ion doses in the range (2.3-5.4)x10 16 ionscm -2 and average ion energies of 60 and 90keV. The implanted layer was examined by Rutherford backscattering, from which the retained doses were determined, and glow discharge optical emission spectroscopy. Following implantation, the surface microhardness was observed to increase with the greatest change occurring at higher ion energy. Pin-on-disc wear tests and associated friction measurements were also performed under both dry and lubricated conditions using applied loads of 2N and 10N. In the absence of lubrication, breakthrough of the implanted layer occurred after a short sliding time; only for a dose of 5.1x10 16 ionscm -2 implanted at an average energy of 90keV was the onset of breakthrough appreciably delayed. In contrast, the results of tests with lubrication showed a more gradual variation, with the extent of wear decreasing with implant dose at both 2N and 10N loads. Finally, the influence of Ti implantation on possible wear mechanisms is discussed in the light of information provided by several surface characterization techniques. ((orig.))

  18. Disc-halo interactions in ΛCDM

    Science.gov (United States)

    Bauer, Jacob S.; Widrow, Lawrence M.; Erkal, Denis

    2018-05-01

    We present a new method for embedding a stellar disc in a cosmological dark matter halo and provide a worked example from a Λ cold dark matter zoom-in simulation. The disc is inserted into the halo at a redshift z = 3 as a zero-mass rigid body. Its mass and size are then increased adiabatically while its position, velocity, and orientation are determined from rigid-body dynamics. At z = 1, the rigid disc (RD) is replaced by an N-body disc whose particles sample a three-integral distribution function (DF). The simulation then proceeds to z = 0 with live disc (LD) and halo particles. By comparison, other methods assume one or more of the following: the centre of the RD during the growth phase is pinned to the minimum of the halo potential, the orientation of the RD is fixed, or the live N-body disc is constructed from a two rather than three-integral DF. In general, the presence of a disc makes the halo rounder, more centrally concentrated, and smoother, especially in the innermost regions. We find that methods in which the disc is pinned to the minimum of the halo potential tend to overestimate the amount of adiabatic contraction. Additionally, the effect of the disc on the subhalo distribution appears to be rather insensitive to the disc insertion method. The LD in our simulation develops a bar that is consistent with the bars seen in late-type spiral galaxies. In addition, particles from the disc are launched or `kicked up' to high galactic latitudes.

  19. Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.

    Science.gov (United States)

    Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G

    2012-06-01

    We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.

  20. The comparative analysis of rocks' resistance to forward-slanting disc cutters and traditionally installed disc cutters

    Science.gov (United States)

    Zhang, Zhao-Huang; Fei, Sun; Liang, Meng

    2016-08-01

    At present, disc cutters of a full face rock tunnel boring machine are mostly mounted in the traditional way. Practical use in engineering projects reveals that this installation method not only heavily affects the operation life of disc cutters, but also increases the energy consumption of a full face rock tunnel boring machine. To straighten out this issue, therefore, a rock-breaking model is developed for disc cutters' movement after the research on the rock breaking of forward-slanting disc cutters. Equations of its displacement are established based on the analysis of velocity vector of a disc cutter's rock-breaking point. The functional relations then are brought forward between the displacement parameters of a rock-breaking point and its coordinate through the analysis of micro displacement of a rock-breaking point. Thus, the geometric equations of rock deformation are derived for the forward-slanting installation of disc cutters. With a linear relationship remaining between the acting force and its deformation either before or after the leap breaking, the constitutive relation of rock deformation can be expressed in the form of generalized Hooke law, hence the comparative analysis of the variation in the resistance of rock to the disc cutters mounted in the forward-slanting way with that in the traditional way. It is discovered that with the same penetration, strain of the rock in contact with forward-slanting disc cutters is apparently on the decline, in other words, the resistance of rock to disc cutters is reduced. Thus wear of disc cutters resulted from friction is lowered and energy consumption is correspondingly decreased. It will be useful for the development of installation and design theory of disc cutters, and significant for the breakthrough in the design of full face rock tunnel boring machine.

  1. A Simulation Model of Focus and Radial Servos in Compact Disc Players with Disc Surface Defects

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Andersen, Palle

    2004-01-01

    Compact Disc players have been on the market in more than two decades.As a consequence most of the control servo problems have been solved. A large remaining problem to solve is the handling of Compact Discs with severe surface defects like scratches and fingerprints. This paper introduces a method...... for making the design of controllers handling surface defects easier. A simulation model of Compact Disc players playing discs with surface defects is presented. The main novel element in the model is a model of the surface defects. That model is based on data from discs with surface defects. This model...

  2. Intratracheal Seal Disc

    DEFF Research Database (Denmark)

    Christiansen, Karen J; Moeslund, Niels; Lauridsen, Henrik

    2017-01-01

    . The device consisted of an intratracheal silicone seal disc fixated by a cord through the stoma to an external part. At day 14, computed tomography (CT) was performed before the device was extracted. With the pulling of a cord, the disc unraveled into a thin thread and was extracted through the stoma. At day...

  3. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    OpenAIRE

    Luo Jun; Wang Zhiqian; Shen Chengwu; Wen Zhuoman; Liu Shaojin; Cai Sheng; Li Jianrong

    2015-01-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendic...

  4. MR image assessment of disc configuration and degree of anterior disc displacement in internal derangement related to age

    International Nuclear Information System (INIS)

    Igarashi, Chinami; Kobayashi, Kaoru; Imanaka, Masahiro; Yuasa, Masao; Yamamoto, Akira

    1999-01-01

    This study was designed to evaluate the configuration of the articular disc and degree of anterior disc displacement on magnetic resonance (MR) imagings in temporomandibular joints (TMJs) with internal derangement. A total of 363 joints diagnosed as having anterior disc displacement with reduction (ADD w R) and 523 joints diagnosed as having anterior disc displacement without reduction (ADD wo R) by MR imaging were examined. These joints did not show severe osseous changes on the condylar head or glenoid fossa. We assessed the configuration of the articular disc and degree of anterior disc displacement. In the ADD w R group, 82.6% of the articular discs showed biconcave configuration; enlargement of the posterior band in 4.6%, biconvex configuration in 0.5%, and others in 10.7%. Moreover 62.5% of the discs showed a slight degree of anterior disc displacement; were 27.2% moderately displaced and were 10.2% severe displaced. The prevalence of slightly displaced discs was higher in the TMJs of cases over 50 years of age than in cases under 30 years in the ADD w R group. On the other hand, in the ADD wo R group 35.9% of the articular discs showed biconcave configuration; enlargement of the posterior band in 12.6%, biconvex configuration in 25.4%, and others in 22.3%. Furthermore, 4.4% of the discs were slightly displaced; 43.9% moderately displaced and 51.6% were severely displaced. The prevalence of severely displaced and deformed discs in joints of cases over 40 years of age was high in the ADD wo R group. The prevalence of slightly displaced biconcave discs was higher in the ADD w R group. The other hand, the prevalence of severely displaced deformed discs was higher in the ADD wo R group. MR findings of internal derangement of the TMJ were found to be significantly correlated with age. (author)

  5. Accuracy of impressions with different impression materials in angulated implants.

    Science.gov (United States)

    Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R

    2013-01-01

    To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.

  6. Magnetic configurations of the tilted current sheets in magnetotail

    Directory of Open Access Journals (Sweden)

    C. Shen

    2008-11-01

    Full Text Available In this research, the geometrical structures of tilted current sheet and tail flapping waves have been analysed based on multiple spacecraft measurements and some features of the tilted current sheets have been made clear for the first time. The geometrical features of the tilted current sheet revealed in this investigation are as follows: (1 The magnetic field lines (MFLs in the tilted current sheet are generally plane curves and the osculating planes in which the MFLs lie are about vertical to the equatorial plane, while the normal of the tilted current sheet leans severely to the dawn or dusk side. (2 The tilted current sheet may become very thin, the half thickness of its neutral sheet is generally much less than the minimum radius of the curvature of the MFLs. (3 In the neutral sheet, the field-aligned current density becomes very large and has a maximum value at the center of the current sheet. (4 In some cases, the current density is a bifurcated one, and the two humps of the current density often superpose two peaks in the gradient of magnetic strength, indicating that the magnetic gradient drift current is possibly responsible for the formation of the two humps of the current density in some tilted current sheets. Tilted current sheets often appear along with tail current sheet flapping waves. It is found that, in the tail flapping current sheets, the minimum curvature radius of the MFLs in the current sheet is rather large with values around 1 RE, while the neutral sheet may be very thin, with its half thickness being several tenths of RE. During the flapping waves, the current sheet is tilted substantially, and the maximum tilt angle is generally larger than 45°. The phase velocities of these flapping waves are several tens km/s, while their periods and wavelengths are several tens of minutes, and several earth radii, respectively. These tail flapping events generally last several hours and occur during quiet periods or periods of

  7. Tumor regression induced by intratumor therapy with a disabled infectious single cycle (DISC) herpes simplex virus (HSV) vector, DISC/HSV/murine granulocyte-macrophage colony-stimulating factor, correlates with antigen-specific adaptive immunity.

    Science.gov (United States)

    Ali, Selman A; Lynam, June; McLean, Cornelia S; Entwisle, Claire; Loudon, Peter; Rojas, José M; McArdle, Stephanie E B; Li, Geng; Mian, Shahid; Rees, Robert C

    2002-04-01

    Direct intratumor injection of a disabled infectious single cycle HSV-2 virus encoding the murine GM-CSF gene (DISC/mGM-CSF) into established murine colon carcinoma CT26 tumors induced a significant delay in tumor growth and complete tumor regression in up to 70% of animals. Pre-existing immunity to HSV did not reduce the therapeutic efficacy of DISC/mGM-CSF, and, when administered in combination with syngeneic dendritic cells, further decreased tumor growth and increased the incidence of complete tumor regression. Direct intratumor injection of DISC/mGM-CSF also inhibited the growth of CT26 tumor cells implanted on the contralateral flank or seeded into the lungs following i.v. injection of tumor cells (experimental lung metastasis). Proliferation of splenocytes in response to Con A was impaired in progressor and tumor-bearer, but not regressor, mice. A potent tumor-specific CTL response was generated from splenocytes of all mice with regressing, but not progressing tumors following in vitro peptide stimulation; this response was specific for the gp70 AH-1 peptide SPSYVYHQF and correlated with IFN-gamma, but not IL-4 cytokine production. Depletion of CD8(+) T cells from regressor splenocytes before in vitro stimulation with the relevant peptide abolished their cytolytic activity, while depletion of CD4(+) T cells only partially inhibited CTL generation. Tumor regression induced by DISC/mGM-CSF virus immunotherapy provides a unique model for evaluating the immune mechanism(s) involved in tumor rejection, upon which tumor immunotherapy regimes may be based.

  8. Enhanced wear resistance of production tools and steel samples by implantation of nitrogen and carbon ions

    International Nuclear Information System (INIS)

    Mikkelsen, N.J.; Straede, C.A.

    1992-01-01

    In recent years ion implantation has become a feasible technique for obtaining improved wear resistance of production tools. However, basic knowledge of how and in which cases ion implantation is working at its best is still needed. The present paper discusses structural and tribological investigations of carbon and nitrogen implanted steels. The nitrogen data were obtained mainly from field tests and the investigation of carbon implantations took place mainly in the laboratory. A study was made of how the tribological behaviour of implanted steels changes with different implantation parameters. The tribological laboratory investigations were carried out using pin-on-disc equipment under controlled test conditions, and deal with high dose carbon implantation (approximately (1-2)x10 18 ions cm -2 ). The wear resistance of steels was enhanced dramatically, by up to several orders of magnitude. The field test results cover a broad range of ion implanted production tools, which showed a marked improvement in wear resistance. Nitrogen implanted tools are also compared with carbon and titanium implanted tools. (orig.)

  9. Lumbar disc excision through fenestration

    Directory of Open Access Journals (Sweden)

    Sangwan S

    2006-01-01

    Full Text Available Background : Lumbar disc herniation often causes sciatica. Many different techniques have been advocated with the aim of least possible damage to other structures while dealing with prolapsed disc surgically in the properly selected and indicated cases. Methods : Twenty six patients with clinical symptoms and signs of prolapsed lumbar intervertebral disc having radiological correlation by MRI study were subjected to disc excision by interlaminar fenestration method. Results : The assessment at follow-up showed excellent results in 17 patients, good in 6 patients, fair in 2 patients and poor in 1 patient. The mean preoperative and postoperative Visual Analogue Scores were 9.34 ±0.84 and 2.19 ±0.84 on scale of 0-10 respectively. These were statistically significant (p value< 0.001, paired t test. No significant complications were recorded. Conclusion : Procedures of interlaminar fenestration and open disc excision under direct vision offers sufficient adequate exposure for lumbar disc excision with a smaller incision, lesser morbidity, shorter convalescence, early return to work and comparable overall results in the centers where recent laser and endoscopy facilities are not available.

  10. Metrical analysis of disc-condyle relation with different splint treatment positions in patients with TMJ disc displacement

    Directory of Open Access Journals (Sweden)

    Mu-Qing Liu

    Full Text Available Abstract Objective: To evaluate the effect of bite positions characterizing different splint treatments (anterior repositioning and stabilization splints on the disc-condyle relation in patients with TMJ disc displacement with reduction (DDwR, using magnetic resonance imaging (MRI. Material and Methods: 37 patients, with a mean age of 18.8±4.3 years (7 male and 30 females and diagnosed with DDwR based on the RDC/TMD, were recruited. MRI metrical analysis of the spatial changes of the disc/condyle, as well as their relationships, was done in three positions: maximum intercuspation (Position 1, anterior repositioning splint position (Position 2, and stabilization splint position (Position 3. Disc/condyle coordinate measurements and disc condyle angles were determined and compared. Results: In Position 1, the average disc-condyle angle was 53.4° in the 60 joints with DDwR, while it was −13.3° with Position 2 and 30.1° with Position 3. The frequency of successful "disc recapture" with Position 2 was significantly higher (58/60, 96.7% than Position 3 (20/60, 33.3%. In Positions 2 and 3, the condyle moved forward and downward while the disc moved backward. The movements were, however, more remarkable with Position 2. Conclusions: Anterior repositioning of the mandible improves the spatial relationship between the disc and condyle in patients with DDwR. In addition to anterior and inferior movement of the condyle, transitory posterior movement of the disc also occurred.

  11. Tibiotalar tilt - a new slant

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, H.; Wandtke, J.

    1981-05-01

    Classically tibiotalar tilt (TTT) is associated with four conditions: Fairbanks disease, hemophilia, sickle-cell anemia and juvenile rheumatoid arthritis. We have found it to be present in at least 20 other conditions including other dysplasias, developmental conditions such as fibrous dysplasia and a variety of other acquired disorders including various metabolic diseases and following previous trauma. The pathogenesis is controversial, but the most probable cause is related to stress and the blood supply of the distal tibial epiphysis. The differentiation of TTT from pseudotibiotalar tilt is also discussed.

  12. Comparative analysis of stress in a new proposal of dental implants.

    Science.gov (United States)

    Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Macedo, Ana Paula; Shimano, Antonio Carlos; Dos Reis, Andréa Cândido

    2017-08-01

    The purpose of this study was to compare, through photoelastic analysis, the stress distribution around conventional and modified external hexagon (EH) and morse taper (MT) dental implant connections. Four photoelastic models were prepared (n=1): Model 1 - conventional EH cylindrical implant (Ø 4.0mm×11mm - Neodent®), Model 2 - modified EH cylindrical implant, Model 3 - conventional MT Conical implant (Ø 4.3mm×10mm - Neodent®) and Model 4 - modified MT conical implant. 100 and 150N axial and oblique loads (30° tilt) were applied in the devices coupled to the implants. A plane transmission polariscope was used in the analysis of fringes and each position of interest was recorded by a digital camera. The Tardy method was used to quantify the fringe order (n), that calculates the maximum shear stress (τ) value in each selected point. The results showed lower stress concentration in the modified cylindrical implant (EH) compared to the conventional model, with application of 150N axial and 100N oblique loads. Lower stress was observed for the modified conical (MT) implant with the application of 100 and 150N oblique loads, which was not observed for the conventional implant model. The comparative analysis of the models showed that the new design proposal generates good stress distribution, especially in the cervical third, suggesting the preservation of bone tissue in the bone crest region. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantization of band tilting in modulated phononic crystals

    Science.gov (United States)

    Nassar, H.; Chen, H.; Norris, A. N.; Huang, G. L.

    2018-01-01

    A general theory of the tilting of dispersion bands in phononic crystals whose properties are being slowly and periodically modulated in space and time is established. The ratio of tilt to modulation speed is calculated, for the first time, in terms of Berry's phase and curvature and is proven to be a robust integer-valued Chern number. Derivations are based on a version of the adiabatic theorem for elastic waves demonstrated thanks to WKB asymptotics. Findings are exemplified in the case of a 3-periodic discrete spring-mass lattice. Tilted dispersion diagrams plotted using fully numerical simulations and semianalytical calculations based on a numerically gauge invariant expression of Berry's phase show perfect agreement. One-way blocking of waves due to the tilt, and ultimately to the breaking of reciprocity, is illustrated numerically and shown to be highly significant across a limited number of unit cells, suggesting the feasibility of experimental demonstrations. Finally, a version of the bulk-edge correspondence principle relating the tilt of bulk bands to the number of one-way gapless edge states is demonstrated.

  14. Disc Golf: Teaching a Lifetime Activity

    Science.gov (United States)

    Eastham, Susan L.

    2015-01-01

    Disc golf is a lifetime activity that can be enjoyed by students of varying skill levels and abilities. Disc golf follows the principles of ball golf but is generally easier for students to play and enjoy success. The object of disc golf is similar to ball golf and involves throwing a disc from the teeing area to the target in as few throws as…

  15. Cell-seeded polyurethane-fibrin structures – A possible system for intervertebral disc regeneration

    Directory of Open Access Journals (Sweden)

    C Mauth

    2009-10-01

    Full Text Available Nowadays, intervertebral disc (IVD degeneration is one of the principal causes of low back pain involving high expense within the health care system. The long-term goal is the development of a medical treatment modality focused on a more biological regeneration of the inner nucleus pulposus (NP. Hence, interest in the endoscopic implantation of an injectable material took center stage in the recent past. We report on the development of a novel polyurethane (PU scaffold as a mechanically stable carrier system for the reimplantation of expanded autologous IVD-derived cells (disc cells to stimulate regenerative processes and restore the chondrocyte-like tissue within the NP. Primary human disc cells were seeded into newly developed PU spheroids which were subsequently encapsulated in fibrin hydrogel. The study aims to analyze adhesion properties, proliferation capacity and phenotypic characterization of these cells. Polymerase chain reaction was carried out to detect the expression of genes specifically expressed by native IVD cells. Biochemical analyses showed an increased DNA content, and a progressive enhancement of total collagen and glycosaminoglycans (GAG was observed during cell culture. The results suggest the synthesis of an appropriate extracellular matrix as well as a stable mRNA expression of chondrogenic and/or NP specific markers. In conclusion, the data presented indicate an alternative medical approach to current treatment options of degenerated IVD tissue.

  16. Black hole spin from wobbling and rotation of the M87 jet and a sign of a magnetically arrested disc

    Science.gov (United States)

    Sob'yanin, Denis Nikolaevich

    2018-06-01

    New long-term Very Long Baseline Array observations of the well-known jet in the M87 radio galaxy at 43 GHz show that the jet experiences a sideways shift with an approximately 8-10 yr quasi-periodicity. Such jet wobbling can be indicative of a relativistic Lense-Thirring precession resulting from a tilted accretion disc. The wobbling period together with up-to-date kinematic data on jet rotation opens up the possibility for estimating angular momentum of the central supermassive black hole. In the case of a test-particle precession, the specific angular momentum is J/Mc = (2.7 ± 1.5) × 1014 cm, implying moderate dimensionless spin parameters a = 0.5 ± 0.3 and 0.31 ± 0.17 for controversial gas-dynamic and stellar-dynamic black hole masses. However, in the case of a solid-body-like precession, the spin parameter is much smaller for both masses, 0.15 ± 0.05. Rejecting this value on the basis of other independent spin estimations requires the existence of a magnetically arrested disc in M87.

  17. Group theoretical analysis of octahedral tilting in perovskites

    International Nuclear Information System (INIS)

    Howard, C.J.; Stokes, H.T.

    1998-01-01

    Full text: Structures of the perovskite family, ABX 3 , have interested crystallographers over many years, and continue to attract attention on account of their fascinating electrical and magnetic properties, for example the giant magnetoresistive effects exhibited by certain perovskite materials. The ideal perovskite (cubic, space group Pm -/3 m) is a particularly simple structure, but also a demanding one, since aside from the lattice parameter there are no variable parameters in the structure. Consequently, the majority of perovskite structures are distorted perovskites (hettotypes), the most common distortion being the corner-linked tilting of the practically rigid BX 6 octahedral units. In this work, group theoretical methods have been applied to the study of octahedral tilting in perovskites. The only irreducible representations of the parent group (Pm -/3 m) which produce octahedral tilting subject to corner-linking constraints are M + / 3 and R 4 ' + . A six-dimensional order parameter in the reducible representation space of M + / 3 + R + / 4 describes the different possible tilting patterns. The space groups for the different perovskites are then simply the isotropy subgroups, comprising those operations which leave the order parameter invariant. The isotropy subgroups are obtained from a computer program or tabulations. The analysis yields a list of fifteen possible space groups for perovskites derived through octahedral tilting. A connection is made to the (twenty-three) tilt systems given previously by Glazer. The group-subgroup relationships have been derived and displayed. It is interesting to note that all known perovskites based on octahedral tilting conform with the fifteen space groups on our list, with the exception of one perovskite at high temperature, the structure of which seems poorly determined

  18. [Partial nucleotomy of the ovine disc as an in vivo model for disc degeneration].

    Science.gov (United States)

    Guder, E; Hill, S; Kandziora, F; Schnake, K J

    2009-01-01

    The aim of this study was to develop a suitable animal model for the clinical situation of progressive disc degeneration after microsurgical nucleotomy. Twenty sheep underwent standardised partial anterolateral nucleotomy at lumbar segment 3/4. After randomisation, 10 animals were sacrificed after 12 weeks (group 1). The remainder was sacrificed after 48 weeks (group 2). For radiological examination X-rays, MRI and post-mortem CT scans were performed. Lumbar discs L 3/4 with adjacent subchondral trabecular bone were harvested and analysed macroscopically and histologically. An image-analysing computer program was used to measure histomorphometric indices of bone structure. 17 segments could be evaluated. After 12 weeks (group 1) histological and radiological degenerative disc changes were noted. After 48 weeks (group 2), radiological signs in MRI reached statistical significance. Furthermore, group 2 showed significantly more osteophyte formations in CT scans. Histomorphometric changes of the disc and the adjacent vertebral bone structure suggest a significant progressive degenerative remodelling. The facet joints did not show any osteoarthrosis after 48 weeks. Partial nucleotomy of the ovine lumbar disc leads to radiological and histological signs of disc degeneration similar to those seen in humans after microsurgical nucleotomy. The presented in vivo model may be useful to evaluate new orthopaedic treatment strategies.

  19. Radiological assessment of loss of disc height during acute and chronic degenerative lumbar disc alterations

    International Nuclear Information System (INIS)

    Zoellner, J.; Sancaktaroglu, T.; Nafe, B.; Eysel, P.; Loew, R.

    2001-01-01

    Aim of the study: A loss of disc height with increasing segmental mobility is an important reason for low back pain. The measurement of hyaluronic acid content of the nucleus pulposus prolaps shows a difference between acute (group 1) and chronic (group 2) disc degeneration. The purpose of the present investigation was to determine the decreasing of disc height between these two groups and the no-symptomatic segments of these patients. Methods: 20 human lateral preoperative X-ray measurements according to Frobin et al. were taken; group 1 with 7 patients (mean age 41 years) and group 2 with 13 patients (mean age 44 years). Results: There was a significant tendency (p=0.091) to a reduction of disc height in group 2 between symptomatic and asymptomatic discs. Conclusion: The used method is not suitable to answer the present question conclusively. (orig.) [de

  20. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

    Science.gov (United States)

    Singh, Ipsha; Nair, K Chandrasekharan; Shetty, Jayakar

    2017-01-01

    The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains). Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains). Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  1. Actuator disc edge singularity. The key to a revised actuator disc concept and momentum theory

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, G.A.M. van (The Wind Energy Group of the Technical University Eindhoven (NL))

    1989-01-01

    Since the beginning of rotor aerodynamics the actuator disc momentum theory occupies a prominant place in almost any textbook on this subject. Specially in axial flow the theory provides an easy and rather accurate performance prediction. The results first obtained by Lanchester for the induced power of a hovering rotor and the maximum power of a wind turbine are still used as guidelines for complicated calculations. On the other hand, experimental results for propellers are known to deviate systematically (some 10%) from the momentum theory results. This is commonly attributed to the differences between a real rotor and an actuator disc. However, some actuator disc- and actuator strip (the 2-dimensional version) experiments are described in literature, showing the same deviations from momentum theory results. Therefore, apart from the question how representative an actuator disc is for a real rotor, the actuator disc concept itself may be inadequate. This problem is the subject of the work describe here. It will be shown that the classical actuator disc concept ignores discrete forces resulting from a flow singularity at the edge of the disc. The (extended) momentum theory, applied to this actuator strip model, shows a shift of the results towards the experimental data, and for the static case (hover) even a quantitative agreement is obtained. (author) 12 refs.

  2. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  3. Study on tribological behaviors of Fe+ ion implanted in 2024 aluminum alloy

    International Nuclear Information System (INIS)

    Zhang Aimin; Chen Jianmin; Shi Weidong; Liu Zhenmin

    2000-01-01

    2024 aluminum alloy was implanted with Fe + ions at a dose of 7x10 16 -3 x 10 17 Fe + /cm 2 . The depth profile of Fe element was investigated by Auger electron spectroscopy (AES). The composition of the surface layer was investigated by XRD with sample-tilting diffraction (STD) mode. The worn out surface was observed by scanning electron microscopy (SEM). Micro-hardness, friction and wear properties have been studied before and after Fe + implantation. An AES analysis shows Fe display Gaussian shape distributions. STD shows Al 5 Fe 2 formed during the implantation. Micro-hardness of surface layer was reduced after implantation, but it did not simply decrease with the increasing implantation doses. The friction and wear tests of implanted and unimplanted samples were carried out on a static-dynamic friction precise measuring apparatus. After implantation, the friction coefficient was reduced from 0.7 to 0.1; the wear resistance was improved remarkably, but decreased with increasing implantation dose. The wear mechanism of the unimplanted sample was adhesive wear, abrasive wear and plastic deformation. The wear reducing effect of Fe + ion induced on 2024 aluminum alloy is mainly attributed to tribooxidation of iron and transfixion of line defect. These two factors prevent the adhesive wear, abrasive wear and plastic deformation of 2024 aluminum alloy

  4. Deep-down ionization of protoplanetary discs

    Science.gov (United States)

    Glassgold, A. E.; Lizano, S.; Galli, D.

    2017-12-01

    The possible occurrence of dead zones in protoplanetary discs subject to the magneto-rotational instability highlights the importance of disc ionization. We present a closed-form theory for the deep-down ionization by X-rays at depths below the disc surface dominated by far-ultraviolet radiation. Simple analytic solutions are given for the major ion classes, electrons, atomic ions, molecular ions and negatively charged grains. In addition to the formation of molecular ions by X-ray ionization of H2 and their destruction by dissociative recombination, several key processes that operate in this region are included, e.g. charge exchange of molecular ions and neutral atoms and destruction of ions by grains. Over much of the inner disc, the vertical decrease in ionization with depth into the disc is described by simple power laws, which can easily be included in more detailed modelling of magnetized discs. The new ionization theory is used to illustrate the non-ideal magnetohydrodynamic effects of Ohmic, Hall and Ambipolar diffusion for a magnetic model of a T Tauri star disc using the appropriate Elsasser numbers.

  5. A new tilt on pelvic radiographs: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Richards, P.J. [North Staffordshire Royal Infirmary, Department of Radiology, Stoke-on-Trent, Staffordshire (United Kingdom); Pattison, J.M. [University Hospital of North Staffordshire, Department of Radiology, Stoke on Trent (United Kingdom); Belcher, J. [Keele University, Department of Mathematics, Keele, Staffordshire (United Kingdom); DeCann, R.W. [IMECS, Department of Radiology, Market Drayton, Shropshire (United Kingdom); Anderson, Suzanne [University of Melbourne, Department of Radiology, Melbourne (Australia); Wynn-Jones, C. [University Hospital of North Staffordshire, Department of Orthopaedic Surgery, Stoke on Trent (United Kingdom)

    2009-02-15

    The aim of this study was to evaluate pelvic tilt on commonly performed measurements on radiography in primary protrusio acetabuli and developmental dysplasia of the hip. A dry assembled pelvis and spine skeleton was positioned in an isocentric skull unit and films exposed with increasing degrees of angulation of pelvic tilt. The films were then read by two independent readers for seven different measurements used to evaluate the hips and acetabular: acetabular line to ilioischial line, teardrop appearance, intercristal/intertuberous ratio, co-ordinates of femoral head, centre edge angle, acetabular depth/width ratio and acetabular angle. There was so much variation in the protrusio results that no formal recommendation of any standard radiographic test can be given. Only the inter tuberous distance is not effected by pelvic tilt. The acetabular angles for developmental dysplasia of the hip showed the most potential with pelvic tilt below 15 . As pelvic tilt increases, measurements used in protusio become unreliable, and computed tomography/magnetic resonance imaging are probably going to be more accurate as one can directly visualise pelvic intrusion. We recommend a lateral view to assess the degree of pelvic tilt in patients with protrusion to ensure these measurements are valid. (orig.)

  6. Tilted hexagonal post arrays: DNA electrophoresis in anisotropic media.

    Science.gov (United States)

    Chen, Zhen; Dorfman, Kevin D

    2014-02-01

    Using Brownian dynamics simulations, we show that DNA electrophoresis in a hexagonal array of micron-sized posts changes qualitatively when the applied electric field vector is not coincident with the lattice vectors of the array. DNA electrophoresis in such "tilted" post arrays is superior to the standard "un-tilted" approach; while the time required to achieve a resolution of unity in a tilted post array is similar to an un-tilted array at a low-electric field strengths, this time (i) decreases exponentially with electric field strength in a tilted array and (ii) increases exponentially with electric field strength in an un-tilted array. Although the DNA dynamics in a post array are complicated, the electrophoretic mobility results indicate that the "free path," i.e. the average distance of ballistic trajectories of point-sized particles launched from random positions in the unit cell until they intersect the next post, is a useful proxy for the detailed DNA trajectories. The analysis of the free path reveals a fundamental connection between anisotropy of the medium and DNA transport therein that goes beyond simply improving the separation device. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Comparison of Heidelberg Retina Tomograph with disc-macula distance to disc diameter ratio in diagnosing optic nerve hypoplasia.

    Science.gov (United States)

    Pang, Yi; Frantz, Kelly A

    2016-05-01

    To evaluate whether Heidelberg Retinal Tomograph (HRT) is a valid test for diagnosing congenital optic nerve hypoplasia (CONH) compared to the ratio of the distance between the centre of the optic disc and the centre of the macula and the mean optic disc diameter (DM:DD ratio). Furthermore, to determine the optimal cut-off value of HRT disc area to differentiate a hypoplastic disc from a normal optic disc. A total of 33 subjects with CONH (4-67 years old) and 160 normal subjects (5-65 years old) were recruited and underwent comprehensive eye examinations, fundus photography and HRT. Receiver operating characteristic curves for DM:DD ratio and HRT disc area were constructed based on data from the 46 CONH eyes and 160 control eyes. Mean (±S.D.) HRT disc area was 1.94 (±0.54) mm(2) for the control eyes and 0.84 (±0.35) mm(2) for the CONH eyes (p < 0.0001). The area under the curve (AUC) for DM:DD ratio was 0.83 (95% confidence interval: 0.76-0.90). The AUC for HRT disc area was 0.96 (95% confidence interval: 0.94-0.99). A statistically significant difference was found between AUC for HRT disc area and that for DM:DD ratio (p = 0.0004). The optimal cut-off value for HRT disc area was 1.42 mm(2) with 95% sensitivity and 85% specificity. The optimal cut-off value for DM:DD ratio was 3.20 with 78% sensitivity and 78% specificity. Both HRT and the DM:DD ratio are valid tests to aid diagnosis of CONH. HRT is superior to DM:DD ratio in diagnosing CONH with higher sensitivity and specificity. We suggest the optimal cut-off value for HRT disc area as 1.42 mm(2) in order to discriminate a hypoplastic disc from a normal optic disc. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  8. Gravito-Inertial Force Resolution in Perception of Synchronized Tilt and Translation

    Science.gov (United States)

    Wood, Scott J.; Holly, Jan; Zhang, Guen-Lu

    2011-01-01

    Natural movements in the sagittal plane involve pitch tilt relative to gravity combined with translation motion. The Gravito-Inertial Force (GIF) resolution hypothesis states that the resultant force on the body is perceptually resolved into tilt and translation consistently with the laws of physics. The purpose of this study was to test this hypothesis for human perception during combined tilt and translation motion. EXPERIMENTAL METHODS: Twelve subjects provided verbal reports during 0.3 Hz motion in the dark with 4 types of tilt and/or translation motion: 1) pitch tilt about an interaural axis at +/-10deg or +/-20deg, 2) fore-aft translation with acceleration equivalent to +/-10deg or +/-20deg, 3) combined "in phase" tilt and translation motion resulting in acceleration equivalent to +/-20deg, and 4) "out of phase" tilt and translation motion that maintained the resultant gravito-inertial force aligned with the longitudinal body axis. The amplitude of perceived pitch tilt and translation at the head were obtained during separate trials. MODELING METHODS: Three-dimensional mathematical modeling was performed to test the GIF-resolution hypothesis using a dynamical model. The model encoded GIF-resolution using the standard vector equation, and used an internal model of motion parameters, including gravity. Differential equations conveyed time-varying predictions. The six motion profiles were tested, resulting in predicted perceived amplitude of tilt and translation for each. RESULTS: The modeling results exhibited the same pattern as the experimental results. Most importantly, both modeling and experimental results showed greater perceived tilt during the "in phase" profile than the "out of phase" profile, and greater perceived tilt during combined "in phase" motion than during pure tilt of the same amplitude. However, the model did not predict as much perceived translation as reported by subjects during pure tilt. CONCLUSION: Human perception is consistent with

  9. Optical bleaching of bismuth implanted silica glass: A threshold effect

    International Nuclear Information System (INIS)

    Park, S.Y.; Magruder, R.H. III; Weeks, R.A.

    1992-01-01

    The near surface regions of high purity silica glass discs, Spectrosil A, were modified by implantation with bismuth ions at 160 key and room temperature. The glasses implanted with a nominal dose of 6x10 16 Bi/cm 2 at ∼5 μA/cm 2 were subsequently bleached with a 5.0 eV KrF pulsed excimer laser. The laser had an average pulse duration of ∼20 ns and repetition rate of 10 Hz. It was found that the bleaching was dependent upon the power density of the laser for a constant total integrated energy. Ion backscattering and optical absorption measurements were made before and after laser irradiation. Large changes in optical density and depth distribution of the implanted ions were observed at power densities of ≥45 mJ/cm 2 -pulse. Onset of threshold for bleaching of silica glass implanted with 6x10 16 Bi/cm 2 at 160 key and at room temperature is between 30 and 45 mJ/cm 2 -pulse

  10. CT findings of lumbar intervertebral disc: II. Disc herniation (HNP)

    International Nuclear Information System (INIS)

    Yang, W. J.; Lee, J. M.; Bahk, Y. W.

    1984-01-01

    In lumbar region the epidural fat pad is relatively abundant so that CT can provides sufficient information in diagnosis of lumbar HNP. Many authors have reported on the CT findings of HNP such as focal nodular protrusion of the posterior disc margin, obliteration of epidural fat pad, impingement of dural sac and nerve root, swelling of nerve root, soft tissue density in the spinal canal and calcification of disc. However there was so previous report describing incidence and reliability of the findings. It is the purpose of the present study to survey the frequency, reliability, and limitation of these CT findings. The clinical material was consisted of 30 operatively proven cases of HNP of the lumbar spine. Each lumbar CT scan was reviewed retrospectively and the findings were analysed by two radiologists independently. There were 20 males and 10 females and the mean age was 36.7 years. Involvement of L4-S5 level was 2.3 times more frequent than that of L5-S1 level. Of 30 cases, 22 were unilateral posterolateral types and 8 cases central or unilateral far lateral types. CT findings observed were nodular protrusion of the posterior margin of the disc, obliteration of epidural fat pad, impingement of dural sac or nerve root, soft tissue density in the spinal canal and calcification in the posterior portion of the protruded disc, in order of decreasing frequency. The conclusions are follows: 1. Nodular protrusion of the posterior disc margin accompanied by obliteration of epidural fat pad was observed in every case. The former findings was designated as direct sign and the latter indirect. 2. Obliteration of the epidural fat appears to be significant in lateral recesses especially when it occurs unilaterally. This was not true, however, in the centrally located fat pad. 3. Impingement of the dural sac and nerve root were observed in 90% and 67%, respectively, and were very helpful in establishing HNP diagnosis when the direct and indirect signs were equivocal

  11. The Galactic stellar disc

    International Nuclear Information System (INIS)

    Feltzing, S; Bensby, T

    2008-01-01

    The study of the Milky Way stellar discs in the context of galaxy formation is discussed. In particular, we explore the properties of the Milky Way disc using a new sample of about 550 dwarf stars for which we have recently obtained elemental abundances and ages based on high-resolution spectroscopy. For all the stars we also have full kinematic information as well as information about their stellar orbits. We confirm results from previous studies that the thin and the thick discs have distinct abundance patterns. But we also explore a larger range of orbital parameters than what has been possible in our previous studies. Several new results are presented. We find that stars that reach high above the Galactic plane and have eccentric orbits show remarkably tight abundance trends. This implies that these stars formed out of well-mixed gas that had been homogenized over large volumes. We find some evidence that suggest that the event that most likely caused the heating of this stellar population happened a few billion years ago. Through a simple, kinematic exploration of stars with super-solar [Fe/H], we show that the solar neighbourhood contains metal-rich, high velocity stars that are very likely associated with the thick disc. Additionally, the HR1614 moving group and the Hercules and Arcturus stellar streams are discussed and it is concluded that, probably, a large fraction of the groups and streams so far identified in the disc are the result of evolution and interactions within the stellar disc rather than being dissolved stellar clusters or engulfed dwarf galaxies.

  12. Optimum tilt angle and orientation for solar collectors in Syria

    International Nuclear Information System (INIS)

    Skeiker, Kamal

    2009-01-01

    One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle) for the solar collector in the main Syrian zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle) maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of approximately 30% more than the case of a solar collector fixed on a horizontal surface.

  13. A Horizontal Tilt Correction Method for Ship License Numbers Recognition

    Science.gov (United States)

    Liu, Baolong; Zhang, Sanyuan; Hong, Zhenjie; Ye, Xiuzi

    2018-02-01

    An automatic ship license numbers (SLNs) recognition system plays a significant role in intelligent waterway transportation systems since it can be used to identify ships by recognizing the characters in SLNs. Tilt occurs frequently in many SLNs because the monitors and the ships usually have great vertical or horizontal angles, which decreases the accuracy and robustness of a SLNs recognition system significantly. In this paper, we present a horizontal tilt correction method for SLNs. For an input tilt SLN image, the proposed method accomplishes the correction task through three main steps. First, a MSER-based characters’ center-points computation algorithm is designed to compute the accurate center-points of the characters contained in the input SLN image. Second, a L 1- L 2 distance-based straight line is fitted to the computed center-points using M-estimator algorithm. The tilt angle is estimated at this stage. Finally, based on the computed tilt angle, an affine transformation rotation is conducted to rotate and to correct the input SLN horizontally. At last, the proposed method is tested on 200 tilt SLN images, the proposed method is proved to be effective with a tilt correction rate of 80.5%.

  14. Björk-Shiley strut fracture and disc escape: literature review and a method of disc retrieval.

    Science.gov (United States)

    Hendel, P N

    1989-03-01

    Embolization of a prosthetic valve poppet is a rare but life-threatening event. It was reported sporadically before the introduction of the Björk-Shiley 70-degree convexoconcave prosthesis in 1980. Since that time, there have been a large number of reported mechanical failures with disc escape. The rate for the 29-mm to 33-mm mitral valves is estimated as 5.2%. In 29 of 35 patients (including the 2 presented here) in whom the site of disc lodgment could be determined, the disc was in the descending or abdominal aorta. Fifteen of these patients died. Six survivors had the disc removed at the same operation and 6 at a later operation. In 2 patients, the disc was not removed. In 2 patients in whom the disc was not removed initially, it was thought to contribute to postoperative complications. Two more cases of structural failure of the Björk-Shiley convexoconcave prosthesis are presented. A transpericardial approach to the descending aorta on bypass is described. It allows easy removal of the disc and eliminates the need for a second operation.

  15. Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries

    Directory of Open Access Journals (Sweden)

    Xiangjia Zhu

    2017-01-01

    Full Text Available Purpose. To evaluate the tilt, decentration, and internal higher-order aberrations (HOAs of sutured posterior-chamber intraocular lenses (IOLs in patients with open globe injuries. Methods. 46 consecutive patients (47 eyes who underwent transsclerally sutured IOL implantation were enrolled in this prospective cohort study. Nineteen eyes had a history of open globe injury. The tilt and decentration of the IOLs and the visual quality were measured 1 month after surgery. Results. The horizontal tilt and decentration of the IOLs in the open-globe-injury group were significantly higher than those in the control group (both P<0.05. In the open-globe-injury group, the horizontal decentration was significantly greater in the limbus-sclera-involved group (n=11 than in the only-cornea-involved group (n=8, P=0.040. The internal coma, 3rd-order, and total HOA values at pupil sizes of 4 mm (P=0.006 and 6 mm (P=0.013 were significantly higher in the open-globe-injury group than in the controls. Consequently, the optical quality data for the modulation transfer function and the Strehl ratio (all P<0.05 were significantly poorer in the open-globe-injury group. Conclusions. Open globe injuries damage the structural integrity of the eyeball, resulting in more-misaligned sutured IOLs and poorer visual quality.

  16. In vitro evaluation of a multispecies oral biofilm on different implant surfaces

    International Nuclear Information System (INIS)

    Violant, Deborah; Galofré, Marta; Nart, José; Teles, Ricardo Patricio

    2014-01-01

    Biofilm accumulation on implant surfaces is one of the most important factors for early and late implant failure. Because of the related clinical implications, the aim of this in vitro study was to compare the bacterial cell attachment of a four-species oral biofilm on titanium discs of purity grade 2 and 4, with machined surfaces and etched-thermochemically modified with Avantblast®. The in vitro biofilm model was composed of early (Actinomyces naeslundii, Streptococcus gordonii), secondary (Veillonella parvula), and intermediate (Fusobacterium nucleatum ssp. polymorphum) colonizers of tooth surfaces. A total of 36 discs were divided into four groups: Tigr2-c (titanium grade 2, machined surface), Tigr2-t (titanium grade 2, modified surface with Avantblast®), Tigr4-c (titanium grade 4, machined surface), Tigr4-t (titanium grade 4, modified surface with Avantblast®). The experiment was repeated three times. Biofilm viability was tested with 1% 2, 3, 5-triphenyltetrazolium chloride solution and bacterial cell quantification by checkerboard DNA–DNA hybridization. Descriptive analysis was performed to evaluate biofilm composition and differences between groups were checked with the Mann–Whitney test (p < 0.05). After one week, multispecies biofilms showed a similar pattern of bacterial composition on all analyzed implant surfaces. The most prevalent bacterium was V. parvula (∼50% of the total biomass), followed by S. gordonii (∼30%), F. nucleatum ssp. polymorphum (∼10%) and A. naeslundii (<5%). Total bacterial biomass was significantly higher in both grade-4-titanium surfaces (p < 0.05). The results demonstrated that not only implant surface treatment, but also titanium purity, influence early bacterial colonization. (paper)

  17. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Wen, Zhuoman; Liu, Shaojin; Cai, Sheng; Li, Jianrong

    2015-10-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  18. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Directory of Open Access Journals (Sweden)

    Luo Jun

    2015-10-01

    Full Text Available This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  19. Use of Temporary Implantable Biomaterials to Reduce Leg Pain and Back Pain in Patients with Sciatica and Lumbar Disc Herniation

    Directory of Open Access Journals (Sweden)

    Gere S. diZerega

    2010-05-01

    Full Text Available The principle etiology of leg pain (sciatica from lumbar disc herniation is mechanical compression of the nerve root. Sciatica is reduced by decompression of the herniated disc, i.e., removing mechanical compression of the nerve root. Decompression surgery typically reduces sciatica more than lumbar back pain (LBP. Decompression surgery reduces mechanical compression of the nerve root. However, decompression surgery does not directly reduce sensitization of the sensory nerves in the epidural space and disc. In addition, sensory nerves in the annulus fibrosus and epidural space are not protected from topical interaction with pain mediators induced by decompression surgery. The secondary etiology of sciatica from lumbar disc herniation is sensitization of the nerve root. Sensitization of the nerve root results from a mechanical compression, b exposure to cellular pain mediators, and/or c exposure to biochemical pain mediators. Although decompression surgery reduces nerve root compression, sensory nerve sensitization often persists. These observations are consistent with continued exposure of tissue in the epidural space, including the nerve root, to increased cellular and biochemical pain mediators following surgery. A potential contributor to lumbar back pain (LBP is stimulation of sensory nerves in the annulus fibrosus by a cellular pain mediators and/or b biochemical pain mediators that accompany annular tears or disruption. Sensory fibers located in the outer one-third of the annulus fibrosus increase in number and depth as a result of disc herniation. The nucleus pulposus is comprised of material that can produce an autoimmune stimulation of the sensory nerves located in the annulus and epidural space leading to LBP. The sensory nerves of the annulus fibrosus and epidural space may be sensitized by topical exposure to cellular and biochemical pain mediators induced by lumbar surgery. Annulotomy or annular rupture allows the nucleus pulposus

  20. Multi-scale modeling of photopolymerization for medical hydrogel-implant design

    Science.gov (United States)

    Schmocker, Andreas; Khoushabi, Azadeh; Farahi, Salma; Pioletti, Dominique; Bourban, Pierre-Etienne; Manson, Jan A.; Moser, Christophe

    2013-02-01

    We report on the modeling of a photopolymerizable hydrogel and its application as a replacement of the interior of the intervertebral disc (so called Nucleus Pulposus). The hydrogel is initially injected in its liquid form and then photopolymerized via a small catheter. Therefore, also the light necessary for the photopolymerization is constrained to a small light guide to keep the surgical procedure as minimally invasive as possible. Hence, the hydrogel is photopolymerized inside. For applications with restricted physical access and illumination time, such as an Nucleus Pulposus replacement, photopolymerization of volumes with a large volume/illumination-area ratio becomes highly challenging. During polymerization, the material's absorption and scattering coefficients change and directly influence local polymerization rates. By understanding and controlling such polymerization patterns, local material properties can be engineered (e.g. elastic modulus, swelling ratio), to match the set of mechanical requirements for the implant. Thus, it is essential to better understand and model photopolymerization reactions. Experiments were conducted by polymerizing a hydrogel in a column-like volume using an optical fiber for light delivery. Quantitative scattering and absorption values as well as monomer conversion rates of the hydrogel sample were validated using a newly established Monte Carlo model for photopolymerization. The results were used to study and predict 3D polymerization patterns for different illumination configurations. In particular, we show an example of a lumbar intervertebral disc replacement where the jelly core of the intervertebral disc (Nucleus Pulposus) is replaced by an in situ photopolymerized hydrogel. The results provide insights for the development of novel endoscopic light-scattering polymerization probes paving the way for a new generation of implantable hydrogels.

  1. Large optics inspection, tilting, and washing stand

    Science.gov (United States)

    Ayers, Marion Jay [Brentwood, CA; Ayers, Shannon Lee [Brentwood, CA

    2010-08-24

    A large optics stand provides a risk free means of safely tilting large optics with ease and a method of safely tilting large optics with ease. The optics are supported in the horizontal position by pads. In the vertical plane the optics are supported by saddles that evenly distribute the optics weight over a large area.

  2. Debris disc constraints on planetesimal formation

    Science.gov (United States)

    Krivov, Alexander V.; Ide, Aljoscha; Löhne, Torsten; Johansen, Anders; Blum, Jürgen

    2018-02-01

    Two basic routes for planetesimal formation have been proposed over the last decades. One is a classical `slow-growth' scenario. Another one is particle concentration models, in which small pebbles are concentrated locally and then collapse gravitationally to form planetesimals. Both types of models make certain predictions for the size spectrum and internal structure of newly born planetesimals. We use these predictions as input to simulate collisional evolution of debris discs left after the gas dispersal. The debris disc emission as a function of a system's age computed in these simulations is compared with several Spitzer and Herschel debris disc surveys around A-type stars. We confirm that the observed brightness evolution for the majority of discs can be reproduced by classical models. Further, we find that it is equally consistent with the size distribution of planetesimals predicted by particle concentration models - provided the objects are loosely bound `pebble piles' as these models also predict. Regardless of the assumed planetesimal formation mechanism, explaining the brightest debris discs in the samples uncovers a `disc mass problem'. To reproduce such discs by collisional simulations, a total mass of planetesimals of up to ˜1000 Earth masses is required, which exceeds the total mass of solids available in the protoplanetary progenitors of debris discs. This may indicate that stirring was delayed in some of the bright discs, that giant impacts occurred recently in some of them, that some systems may be younger than previously thought or that non-collisional processes contribute significantly to the dust production.

  3. T1 hyperintense disc in alkaptonuria.

    Science.gov (United States)

    Sag, Alan A; Silbergleit, Richard; Olson, Rick E; Wilson, Jon; Krishnan, Anant

    2012-10-01

    Case report. To report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation. A 46-year-old man without previous diagnosis of alkaptonuria underwent evaluation for progressive back pain revealing a T1-hyperintense disc herniation at the L3-L4 level. Discectomy recovered a blackened disc that was pathologically confirmed to be nucleus pulposus with alkaptonuric involvement. The differential diagnosis of a T1-hyperintense, T2-hypointense disc on magnetic resonance imaging is discussed, with emphasis on the pathophysiology of alkaptonuria. A single patient is reported. Pathologically proven patient presentation with radiological and pathological images. We report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation.

  4. RE-EXAMINING SUNSPOT TILT ANGLE TO INCLUDE ANTI-HALE STATISTICS

    Energy Technology Data Exchange (ETDEWEB)

    McClintock, B. H. [University of Southern Queensland, Toowoomba, 4350 (Australia); Norton, A. A. [HEPL, Stanford University, Palo Alto, CA 94305 (United States); Li, J., E-mail: u1049686@umail.usq.edu.au, E-mail: aanorton@stanford.edu, E-mail: jli@igpp.ucla.edu [Department of Earth, Planetary, and Space Sciences, University of California at Los Angeles, Los Angeles, CA 90095 (United States)

    2014-12-20

    Sunspot groups and bipolar magnetic regions (BMRs) serve as an observational diagnostic of the solar cycle. We use Debrecen Photohelographic Data (DPD) from 1974-2014 that determined sunspot tilt angles from daily white light observations, and data provided by Li and Ulrich that determined sunspot magnetic tilt angle using Mount Wilson magnetograms from 1974-2012. The magnetograms allowed for BMR tilt angles that were anti-Hale in configuration, so tilt values ranged from 0 to 360° rather than the more common ±90°. We explore the visual representation of magnetic tilt angles on a traditional butterfly diagram by plotting the mean area-weighted latitude of umbral activity in each bipolar sunspot group, including tilt information. The large scatter of tilt angles over the course of a single cycle and hemisphere prevents Joy's law from being visually identified in the tilt-butterfly diagram without further binning. The average latitude of anti-Hale regions does not differ from the average latitude of all regions in both hemispheres. The distribution of anti-Hale sunspot tilt angles are broadly distributed between 0 and 360° with a weak preference for east-west alignment 180° from their expected Joy's law angle. The anti-Hale sunspots display a log-normal size distribution similar to that of all sunspots, indicating no preferred size for anti-Hale sunspots. We report that 8.4% ± 0.8% of all bipolar sunspot regions are misclassified as Hale in traditional catalogs. This percentage is slightly higher for groups within 5° of the equator due to the misalignment of the magnetic and heliographic equators.

  5. RE-EXAMINING SUNSPOT TILT ANGLE TO INCLUDE ANTI-HALE STATISTICS

    International Nuclear Information System (INIS)

    McClintock, B. H.; Norton, A. A.; Li, J.

    2014-01-01

    Sunspot groups and bipolar magnetic regions (BMRs) serve as an observational diagnostic of the solar cycle. We use Debrecen Photohelographic Data (DPD) from 1974-2014 that determined sunspot tilt angles from daily white light observations, and data provided by Li and Ulrich that determined sunspot magnetic tilt angle using Mount Wilson magnetograms from 1974-2012. The magnetograms allowed for BMR tilt angles that were anti-Hale in configuration, so tilt values ranged from 0 to 360° rather than the more common ±90°. We explore the visual representation of magnetic tilt angles on a traditional butterfly diagram by plotting the mean area-weighted latitude of umbral activity in each bipolar sunspot group, including tilt information. The large scatter of tilt angles over the course of a single cycle and hemisphere prevents Joy's law from being visually identified in the tilt-butterfly diagram without further binning. The average latitude of anti-Hale regions does not differ from the average latitude of all regions in both hemispheres. The distribution of anti-Hale sunspot tilt angles are broadly distributed between 0 and 360° with a weak preference for east-west alignment 180° from their expected Joy's law angle. The anti-Hale sunspots display a log-normal size distribution similar to that of all sunspots, indicating no preferred size for anti-Hale sunspots. We report that 8.4% ± 0.8% of all bipolar sunspot regions are misclassified as Hale in traditional catalogs. This percentage is slightly higher for groups within 5° of the equator due to the misalignment of the magnetic and heliographic equators

  6. LOTTTTUCE: Layer Oriented Tip-Tilt Turbulence Tomography using Covariance and Elevation

    International Nuclear Information System (INIS)

    Lai, Olivier; Hayano, Yutaka; Oya, Shin; Chun, Mark; Lu, Jessica R; Toomey, Douglas

    2015-01-01

    LOTTTTUCE is based upon the fact that turbulence at the pupil produces correlated tip-tilt motion over the entire field (averaging the tip-tilt across the widest field possible gives the strength of the turbulence at the telescope), while the on-axis (any axis) image motion measures the integrated tip-tilt over the line of sight (single stars provide the variance of the tip-tilt, which allows to infer the integrated seeing). Between these two extremes, the amount of correlation across a given field size is the integral of the turbulence from the ground to the altitude where the tip-tilt decorrelates over the meta-pupil. Differentiating the altitude- integrated tip-tilt with respect to altitude generates an estimate of tip-tilt (hence turbulence, assuming Kolmogorov properties) at each altitude. Alternately, the 3D Fourier transform of a data cube containing the time evolution of the tip (or tilt) across the field allows to determine the amount of energy for “field” frequencies (in other words, the integrated seeing across each same size patches) and the temporal spectrum of each of these features. Differentiating the spectrum with respect to spatial frequency would provide the amount of energy, as well as speed and direction, of each layer. The LOTTTTUCE method is a novel method of measuring the vertical turbulence profile that uses wide field tip-tilt information such as that provided by Pan-STARRS. However, the method also has limitations due to tip-tilt decorrelation as a function of meta-pupil overlap, finite outer scale, and non-Kolmogorov power spectrum. (paper)

  7. Non-axisymmetric line-driven disc winds - I. Disc perturbations

    Science.gov (United States)

    Dyda, Sergei; Proga, Daniel

    2018-04-01

    We study mass outflows driven from accretion discs by radiation pressure due to spectral lines. To investigate non-axisymmetric effects, we use the ATHENA++ code and develop a new module to account for radiation pressure driving. In 2D, our new simulations are consistent with previous 2D axisymmetric solutions by Proga et al., who used the ZEUS 2D code. Specifically, we find that the disc winds are time dependent, characterized by a dense stream confined to ˜45° relative to the disc mid-plane and bounded on the polar side by a less dense, fast stream. In 3D, we introduce a vertical, ϕ-dependent, subsonic velocity perturbation in the disc mid-plane. The perturbation does not change the overall character of the solution but global outflow properties such as the mass, momentum, and kinetic energy fluxes are altered by up to 100 per cent. Non-axisymmetric density structures develop and persist mainly at the base of the wind. They are relatively small, and their densities can be a few times higher than the azimuthal average. The structure of the non-axisymmetric and axisymmetric solutions differ also in other ways. Perhaps most importantly from the observational point of view are the differences in the so-called clumping factors, that serve as a proxy for emissivity due to two body processes. In particular, the spatially averaged clumping factor over the entire fast stream, while it is of a comparable value in both solutions, it varies about 10 times faster in the non-axisymmetric case.

  8. The presence and absence of lymphatic vessels in the adult human intervertebral disc: relation to disc pathology

    International Nuclear Information System (INIS)

    Kliskey, Karolina; Williams, Kelly; Yu, J.; Urban, Jill; Athanasou, Nick; Jackson, David

    2009-01-01

    Although the normal adult human intervertebral disc is considered to be avascular, vascularised cellular fibrous tissue can be found in pathological conditions involving the disc such as disc herniation. Whether lymphatics vessels form a component of this reparative tissue is not known as the presence or absence of lymphatics in herniated and normal disc tissue is not known. We examined spinal tissues and discectomy specimens for the presence of lymphatics. The examination used immunohistochemistry to identify the specific lymphatic endothelial cell markers, podoplanin and LYVE1. Lymphatic vessels were not found in the nucleus pulposus or annulus fibrosus of intact, non-herniated lumbar and thoracic discs but were present in the surrounding ligaments. Ingrowth of fibrous tissue was seen in 73% of herniated disc specimens of which 36% contained LYVE1+/podoplanin + lymphatic vessels. Lymphatic vessels were not seen in the sacrum and coccyx or biopsies of four sacrococcygeal chordomas, but they were noted in surrounding extra-osseous fat and fibrous tissue at the edge of the infiltrating tumour. Our findings indicate that lymphatic vessels are not present in the normal adult intervertebral disc but that, when there is extrusion of disc material into surrounding soft tissue, there is ingrowth of reparative fibrous tissue containing lymphatic vessels. Our findings also indicate that chordoma, a tumour of notochordal origin, spreads to regional lymph nodes via lymphatics in para-spinal soft tissues. (orig.)

  9. Archival-grade optical disc design and international standards

    Science.gov (United States)

    Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo

    2015-09-01

    Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.

  10. Age, splanchnic vasoconstriction, and heat stress during tilting

    Science.gov (United States)

    Minson, C. T.; Wladkowski, S. L.; Pawelczyk, J. A.; Kenney, W. L.

    1999-01-01

    During upright tilting, blood is translocated to the dependent veins of the legs and compensatory circulatory adjustments are necessary to maintain arterial pressure. For examination of the effect of age on these responses, seven young (23 +/- 1 yr) and seven older (70 +/- 3 yr) men were head-up tilted to 60 degrees in a thermoneutral condition and during passive heating with water-perfused suits. Measurements included heart rate (HR), cardiac output (Qc; acetylene rebreathing technique), central venous pressure (CVP), blood pressures, forearm blood flow (venous occlusion plethysmography), splanchnic and renal blood flows (indocyanine green and p-aminohippurate clearance), and esophageal and mean skin temperatures. In response to tilting in the thermoneutral condition, CVP and stroke volume decreased to a greater extent in the young men, but HR increased more, such that the fall in Qc was similar between the two groups in the upright posture. The rise in splanchnic vascular resistance (SVR) was greater in the older men, but the young men increased forearm vascular resistance (FVR) to a greater extent than the older men. The fall in Qc during combined heat stress and tilting was greater in the young compared with older men. Only four of the young men versus six of the older men were able to finish the second tilt without becoming presyncopal. In summary, the older men relied on a greater increase in SVR to compensate for a reduced ability to constrict the skin and muscle circulations (as determined by changes in FVR) during head-up tilting.

  11. Thermochemical modelling of brown dwarf discs

    NARCIS (Netherlands)

    Greenwood, A. J.; Kamp, I.; Waters, L. B. F. M.; Woitke, P.; Thi, W.-F.; Rab, Ch.; Aresu, G.; Spaans, M.

    The physical properties of brown dwarf discs, in terms of their shapes and sizes, are still largely unexplored by observations. ALMA has by far the best capabilities to observe these discs in sub-mm CO lines and dust continuum, while also spatially resolving some discs. To what extent brown dwarf

  12. NUMERICAL SIMULATIONS OF NATURALLY TILTED, RETROGRADELY PRECESSING, NODAL SUPERHUMPING ACCRETION DISKS

    International Nuclear Information System (INIS)

    Montgomery, M. M.

    2012-01-01

    Accretion disks around black hole, neutron star, and white dwarf systems are thought to sometimes tilt, retrogradely precess, and produce hump-shaped modulations in light curves that have a period shorter than the orbital period. Although artificially rotating numerically simulated accretion disks out of the orbital plane and around the line of nodes generate these short-period superhumps and retrograde precession of the disk, no numerical code to date has been shown to produce a disk tilt naturally. In this work, we report the first naturally tilted disk in non-magnetic cataclysmic variables using three-dimensional smoothed particle hydrodynamics. Our simulations show that after many hundreds of orbital periods, the disk has tilted on its own and this disk tilt is without the aid of radiation sources or magnetic fields. As the system orbits, the accretion stream strikes the bright spot (which is on the rim of the tilted disk) and flows over and under the disk on different flow paths. These different flow paths suggest the lift force as a source to disk tilt. Our results confirm the disk shape, disk structure, and negative superhump period and support the source to disk tilt, source to retrograde precession, and location associated with X-ray and He II emission from the disk as suggested in previous works. Our results identify the fundamental negative superhump frequency as the indicator of disk tilt around the line of nodes.

  13. Notochord Cells in Intervertebral Disc Development and Degeneration

    Science.gov (United States)

    McCann, Matthew R.; Séguin, Cheryle A.

    2016-01-01

    The intervertebral disc is a complex structure responsible for flexibility, multi-axial motion, and load transmission throughout the spine. Importantly, degeneration of the intervertebral disc is thought to be an initiating factor for back pain. Due to a lack of understanding of the pathways that govern disc degeneration, there are currently no disease-modifying treatments to delay or prevent degenerative disc disease. This review presents an overview of our current understanding of the developmental processes that regulate intervertebral disc formation, with particular emphasis on the role of the notochord and notochord-derived cells in disc homeostasis and how their loss can result in degeneration. We then describe the role of small animal models in understanding the development of the disc and their use to interrogate disc degeneration and associated pathologies. Finally, we highlight essential development pathways that are associated with disc degeneration and/or implicated in the reparative response of the tissue that might serve as targets for future therapeutic approaches. PMID:27252900

  14. Notochord Cells in Intervertebral Disc Development and Degeneration

    Directory of Open Access Journals (Sweden)

    Matthew R. McCann

    2016-01-01

    Full Text Available The intervertebral disc is a complex structure responsible for flexibility, multi-axial motion, and load transmission throughout the spine. Importantly, degeneration of the intervertebral disc is thought to be an initiating factor for back pain. Due to a lack of understanding of the pathways that govern disc degeneration, there are currently no disease-modifying treatments to delay or prevent degenerative disc disease. This review presents an overview of our current understanding of the developmental processes that regulate intervertebral disc formation, with particular emphasis on the role of the notochord and notochord-derived cells in disc homeostasis and how their loss can result in degeneration. We then describe the role of small animal models in understanding the development of the disc and their use to interrogate disc degeneration and associated pathologies. Finally, we highlight essential development pathways that are associated with disc degeneration and/or implicated in the reparative response of the tissue that might serve as targets for future therapeutic approaches.

  15. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model

    Directory of Open Access Journals (Sweden)

    Ipsha Singh

    2017-01-01

    Full Text Available Aim: The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. Materials and Methods: A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Results: Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains. Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains. Conclusions: Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  16. The life cycles of Be viscous decretion discs: fundamental disc parameters of 54 SMC Be stars

    Science.gov (United States)

    Rímulo, L. R.; Carciofi, A. C.; Vieira, R. G.; Rivinius, Th; Faes, D. M.; Figueiredo, A. L.; Bjorkman, J. E.; Georgy, C.; Ghoreyshi, M. R.; Soszyński, I.

    2018-05-01

    Be stars are main-sequence massive stars with emission features in their spectrum, which originates in circumstellar gaseous discs. Even though the viscous decretion disc model can satisfactorily explain most observations, two important physical ingredients, namely the magnitude of the viscosity (α) and the disc mass injection rate, remain poorly constrained. The light curves of Be stars that undergo events of disc formation and dissipation offer an opportunity to constrain these quantities. A pipeline was developed to model these events that use a grid of synthetic light curves, computed from coupled hydrodynamic and radiative transfer calculations. A sample of 54 Be stars from the OGLE survey of the Small Magellanic Cloud (SMC) was selected for this study. Because of the way our sample was selected (bright stars with clear disc events), it likely represents the densest discs in the SMC. Like their siblings in the Galaxy, the mass of the disc in the SMC increases with the stellar mass. The typical mass and angular momentum loss rates associated with the disc events are of the order of ˜10-10 M⊙ yr-1 and ˜5 × 1036 g cm2 s-2, respectively. The values of α found in this work are typically of a few tenths, consistent with recent results in the literature and with the ones found in dwarf novae, but larger than current theory predicts. Considering the sample as a whole, the viscosity parameter is roughly two times larger at build-up ( = 0.63) than at dissipation ( = 0.26). Further work is necessary to verify whether this trend is real or a result of some of the model assumptions.

  17. Correlation between length and tilt of lipid tails

    Science.gov (United States)

    Kopelevich, Dmitry I.; Nagle, John F.

    2015-10-01

    It is becoming recognized from simulations, and to a lesser extent from experiment, that the classical Helfrich-Canham membrane continuum mechanics model can be fruitfully enriched by the inclusion of molecular tilt, even in the fluid, chain disordered, biologically relevant phase of lipid bilayers. Enriched continuum theories then add a tilt modulus κθ to accompany the well recognized bending modulus κ. Different enrichment theories largely agree for many properties, but it has been noticed that there is considerable disagreement in one prediction; one theory postulates that the average length of the hydrocarbon chain tails increases strongly with increasing tilt and another predicts no increase. Our analysis of an all-atom simulation favors the latter theory, but it also shows that the overall tail length decreases slightly with increasing tilt. We show that this deviation from continuum theory can be reconciled by consideration of the average shape of the tails, which is a descriptor not obviously includable in continuum theory.

  18. Correlation between length and tilt of lipid tails

    Energy Technology Data Exchange (ETDEWEB)

    Kopelevich, Dmitry I., E-mail: dkopelevich@che.ufl.edu [Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Nagle, John F., E-mail: nagle@cmu.edu [Department of Physics, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States)

    2015-10-21

    It is becoming recognized from simulations, and to a lesser extent from experiment, that the classical Helfrich-Canham membrane continuum mechanics model can be fruitfully enriched by the inclusion of molecular tilt, even in the fluid, chain disordered, biologically relevant phase of lipid bilayers. Enriched continuum theories then add a tilt modulus κ{sub θ} to accompany the well recognized bending modulus κ. Different enrichment theories largely agree for many properties, but it has been noticed that there is considerable disagreement in one prediction; one theory postulates that the average length of the hydrocarbon chain tails increases strongly with increasing tilt and another predicts no increase. Our analysis of an all-atom simulation favors the latter theory, but it also shows that the overall tail length decreases slightly with increasing tilt. We show that this deviation from continuum theory can be reconciled by consideration of the average shape of the tails, which is a descriptor not obviously includable in continuum theory.

  19. Evaluation of Osseointegration of Titanium Alloyed Implants Modified by Plasma Polymerization

    Directory of Open Access Journals (Sweden)

    Carolin Gabler

    2014-02-01

    Full Text Available By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V coated with plasma-polymerized allylamine (PPAAm and plasma-polymerized ethylenediamine (PPEDA versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%. Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5% and implants with PPEDA a significantly increased BIC (63.7%. In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.

  20. On the illumination of neutron star accretion discs

    Science.gov (United States)

    Wilkins, D. R.

    2018-03-01

    The illumination of the accretion disc in a neutron star X-ray binary by X-rays emitted from (or close to) the neutron star surface is explored through general relativistic ray tracing simulations. The applicability of the canonical suite of relativistically broadened emission line models (developed for black holes) to discs around neutron stars is evaluated. These models were found to describe well emission lines from neutron star accretion discs unless the neutron star radius is larger than the innermost stable orbit of the accretion disc at 6 rg or the disc is viewed at high inclination, above 60° where shadowing of the back side of the disc becomes important. Theoretical emissivity profiles were computed for accretion discs illuminated by hotspots on the neutron star surfaces, bands of emission and emission by the entirety of the hot, spherical star surface and in all cases, the emissivity profile of the accretion disc was found to be well represented by a single power law falling off slightly steeper than r-3. Steepening of the emissivity index was found where the emission is close to the disc plane and the disc can appear truncated when illuminated by a hotspot at high latitude. The emissivity profile of the accretion disc in Serpens X-1 was measured and found to be consistent with a single unbroken power law with index q=3.5_{-0.4}^{+0.3}, suggestive of illumination by the boundary layer between the disc and neutron star surface.

  1. Minimum weight design of inhomogeneous rotating discs

    International Nuclear Information System (INIS)

    Jahed, Hamid; Farshi, Behrooz; Bidabadi, Jalal

    2005-01-01

    There are numerous applications for gas turbine discs in the aerospace industry such as in turbojet engines. These discs normally work under high temperatures while subjected to high angular velocities. Minimizing the weight of such items in aerospace applications results in benefits such as low dead weights and lower costs. High speed of rotation causes large centrifugal forces in a disc and simultaneous application of high temperatures reduces disc material strength. Thus, the latter effects tend to increase deformations of the disc under the applied loads. In order to obtain a reliable disc analysis and arrive at the corresponding correct stress distribution, solutions should consider changes in material properties due to the temperature field throughout the disc. To achieve this goal, an inhomogeneous disc model with variable thickness is considered. Using the variable material properties method, stresses are obtained for the disc under rotation and a steady temperature field. In this paper this is done by modelling the rotating disc as a series of rings of different but constant properties. The optimum disc profile is arrived at by sequentially proportioning the thicknesses of each ring to satisfy the stress requirements. This method vis-a-vis a mathematical programming procedure for optimization shows several advantages. Firstly, it is simple iterative proportioning in each design cycle not requiring involved mathematical operations. Secondly, due to its simplicity it alleviates the necessity of certain simplifications that are common in so-called rigorous mathematical procedures. The results obtained, compared to those published in the literature show agreement and superiority. A further advantage of the proposed method is the independence of the end results from the initially assumed point in the iterative design routine, unlike most methods published so far

  2. Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

    Science.gov (United States)

    Wilson, Thad E.; Cui, Jian; Zhang, Rong; Witkowski, Sarah; Crandall, Craig G.

    2002-01-01

    Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P heat-stressed humans.

  3. The effects of ion implantation on the tribology of perfluoropolyether-lubricated 440C stainless steel couples

    Science.gov (United States)

    Shogrin, Bradley; Jones, William R., Jr.; Wilbur, Paul J.; Pilar, Herrera-Fierro; Williamson, Don L.

    1995-01-01

    The lubricating lifetime of thin films of a perfluoropolyether (PFPE) based on hexafluoropropene oxide in the presence of ion implanted 440C stainless steel is presented. Stainless steel discs, either unimplanted or implanted with N2, C, Ti, Ti + N2, or Ti + C had a thin film of PFPE (60-400 A) applied to them reproducibly (+/- 20 percent) and uniformly (+/- 15 percent) using a device developed for this study. The lifetimes of these films were quantified by measuring the number of sliding-wear cycles required to induce an increase in the friction coefficient from an initial value characteristic of the lubricated wear couple to a final, or failure value, characteristic of an unlubricated, unimplanted couple. The tests were performed in a dry nitrogen atmosphere (less than 1 percent RH) at room temperature using a 3 N normal load with a relative sliding speed of 0.05 m/s. The lubricated lifetime of the 440C couple was increased by an order of magnitude by implanting the disc with Ti. Ranked from most to least effective, the implanted species were: Ti; Ti+C; unimplanted; N2; C approximately equals Ti+N2. The mechanism postulated to explain these results involves the formation of a passivating or reactive layer which inhibits or facilitates the production of active sites. The corresponding surface microstructures induced by ion implantation, obtained using x-ray diffraction and conversion electron Mossbauer spectroscopy, ranked from most to least effective in enhancing lubricant lifetime were: amorphous Fe-Cr-Ti; amorphous Fe-Cr-Ti-C + TiC; unimplanted; epsilon-(Fe,Cr)(sub x)N, x = 2 or 3; amorphous Fe-Cr-C approximately equals amorphous Fe-Cr-Ti-N.

  4. Spectroscopic Parameters of Lumbar Intervertebral Disc Material

    Science.gov (United States)

    Terbetas, G.; Kozlovskaja, A.; Varanius, D.; Graziene, V.; Vaitkus, J.; Vaitkuviene, A.

    2009-06-01

    There are numerous methods of investigating intervertebral disc. Visualization methods are widely used in clinical practice. Histological, imunohistochemical and biochemical methods are more used in scientific research. We propose that a new spectroscopic investigation would be useful in determining intervertebral disc material, especially when no histological specimens are available. Purpose: to determine spectroscopic parameters of intervertebral disc material; to determine emission spectra common for all intervertebral discs; to create a background for further spectroscopic investigation where no histological specimen will be available. Material and Methods: 20 patients, 68 frozen sections of 20 μm thickness from operatively removed intervertebral disc hernia were excited by Nd:YAG microlaser STA-01-TH third harmonic 355 nm light throw 0, 1 mm fiber. Spectrophotometer OceanOptics USB2000 was used for spectra collection. Mathematical analysis of spectra was performed by ORIGIN multiple Gaussian peaks analysis. Results: In each specimen of disc hernia were found distinct maximal spectral peaks of 4 types supporting the histological evaluation of mixture content of the hernia. Fluorescence in the spectral regions 370-700 nm was detected in the disc hernias. The main spectral component was at 494 nm and the contribution of the components with the peak wavelength values at 388 nm, 412 nm and 435±5 nm were varying in the different groups of samples. In comparison to average spectrum of all cases, there are 4 groups of different spectral signatures in the region 400-500 nm in the patient groups, supporting a clinical data on different clinical features of the patients. Discussion and Conclusion: besides the classical open discectomy, new minimally invasive techniques of treating intervertebral disc emerge (PLDD). Intervertebral disc in these techniques is assessed by needle, no histological specimen is taken. Spectroscopic investigation via fiber optics through the

  5. Tilted dipole model for bias-dependent photoluminescence pattern

    Energy Technology Data Exchange (ETDEWEB)

    Fujieda, Ichiro, E-mail: fujieda@se.ritsumei.ac.jp; Suzuki, Daisuke; Masuda, Taishi [Department of Electrical and Electronic Engineering, Ritsumeikan University, Kusatsu 525-8577 (Japan)

    2014-12-14

    In a guest-host system containing elongated dyes and a nematic liquid crystal, both molecules are aligned to each other. An external bias tilts these molecules and the radiation pattern of the system is altered. A model is proposed to describe this bias-dependent photoluminescence patterns. It divides the liquid crystal/dye layer into sub-layers that contain electric dipoles with specific tilt angles. Each sub-layer emits linearly polarized light. Its radiation pattern is toroidal and is determined by the tilt angle. Its intensity is assumed to be proportional to the power of excitation light absorbed by the sub-layer. This is calculated by the Lambert-Beer's Law. The absorption coefficient is assumed to be proportional to the cross-section of the tilted dipole moment, in analogy to the ellipsoid of refractive index, to evaluate the cross-section for each polarized component of the excitation light. Contributions from all the sub-layers are added to give a final expression for the radiation pattern. Self-absorption is neglected. The model is simplified by reducing the number of sub-layers. Analytical expressions are derived for a simple case that consists of a single layer with tilted dipoles sandwiched by two layers with horizontally-aligned dipoles. All the parameters except for the tilt angle can be determined by measuring transmittance of the excitation light. The model roughly reproduces the bias-dependent photoluminescence patterns of a cell containing 0.5 wt. % coumarin 6. It breaks down at large emission angles. Measured spectral changes suggest that the discrepancy is due to self-absorption and re-emission.

  6. Position, Attitude, and Fault-Tolerant Control of Tilting-Rotor Quadcopter

    Science.gov (United States)

    Kumar, Rumit

    The aim of this thesis is to present algorithms for autonomous control of tilt-rotor quadcopter UAV. In particular, this research work describes position, attitude and fault tolerant control in tilt-rotor quadcopter. Quadcopters are one of the most popular and reliable unmanned aerial systems because of the design simplicity, hovering capabilities and minimal operational cost. Numerous applications for quadcopters have been explored all over the world but very little work has been done to explore design enhancements and address the fault-tolerant capabilities of the quadcopters. The tilting rotor quadcopter is a structural advancement of traditional quadcopter and it provides additional actuated controls as the propeller motors are actuated for tilt which can be utilized to improve efficiency of the aerial vehicle during flight. The tilting rotor quadcopter design is accomplished by using an additional servo motor for each rotor that enables the rotor to tilt about the axis of the quadcopter arm. Tilting rotor quadcopter is a more agile version of conventional quadcopter and it is a fully actuated system. The tilt-rotor quadcopter is capable of following complex trajectories with ease. The control strategy in this work is to use the propeller tilts for position and orientation control during autonomous flight of the quadcopter. In conventional quadcopters, two propellers rotate in clockwise direction and other two propellers rotate in counter clockwise direction to cancel out the effective yawing moment of the system. The variation in rotational speeds of these four propellers is utilized for maneuvering. On the other hand, this work incorporates use of varying propeller rotational speeds along with tilting of the propellers for maneuvering during flight. The rotational motion of propellers work in sync with propeller tilts to control the position and orientation of the UAV during the flight. A PD flight controller is developed to achieve various modes of the

  7. Sedimentary basins reconnaissance using the magnetic Tilt-Depth method

    Science.gov (United States)

    Salem, A.; Williams, S.; Samson, E.; Fairhead, D.; Ravat, D.; Blakely, R.J.

    2010-01-01

    We compute the depth to the top of magnetic basement using the Tilt-Depth method from the best available magnetic anomaly grids covering the continental USA and Australia. For the USA, the Tilt-Depth estimates were compared with sediment thicknesses based on drilling data and show a correlation of 0.86 between the datasets. If random data were used then the correlation value goes to virtually zero. There is little to no lateral offset of the depth of basinal features although there is a tendency for the Tilt-Depth results to be slightly shallower than the drill depths. We also applied the Tilt-Depth method to a local-scale, relatively high-resolution aeromagnetic survey over the Olympic Peninsula of Washington State. The Tilt-Depth method successfully identified a variety of important tectonic elements known from geological mapping. Of particular interest, the Tilt-Depth method illuminated deep (3km) contacts within the non-magnetic sedimentary core of the Olympic Mountains, where magnetic anomalies are subdued and low in amplitude. For Australia, the Tilt-Depth estimates also give a good correlation with known areas of shallow basement and sedimentary basins. Our estimates of basement depth are not restricted to regional analysis but work equally well at the micro scale (basin scale) with depth estimates agreeing well with drill hole and seismic data. We focus on the eastern Officer Basin as an example of basin scale studies and find a good level of agreement between previously-derived basin models. However, our study potentially reveals depocentres not previously mapped due to the sparse distribution of well data. This example thus shows the potential additional advantage of the method in geological interpretation. The success of this study suggests that the Tilt-Depth method is useful in estimating the depth to crystalline basement when appropriate quality aeromagnetic anomaly data are used (i.e. line spacing on the order of or less than the expected depth to

  8. Development of rupture discs for the FBTR

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, C.; Anandkumar, V.; Seetharaman, V.; Rajan, K.K.

    1984-01-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. Reverse buckling knife blade concept with austenitic stainless steel disc has been developed for the rupture disc assemblies required for Fast Breeder Test Reactor (FBTR). Hydroforming process without any die has been used for disc fabrication. One rupture disc assembly required for steam generator is undergoing sodium endurance test and has accumulated 4,500 hours. The present status of development work as demonstrated by room temperature experimental results as well as the scope for future work are discussed. (author)

  9. Tilted Lemaitre-Tolman-Bondi spacetimes: Hydrodynamic and thermodynamic properties

    International Nuclear Information System (INIS)

    Herrera, L.; Di Prisco, A.; Ibanez, J.

    2011-01-01

    We consider Lemaitre-Tolman-Bondi spacetimes from the point of view of a tilted observer, i.e. one with respect to which the fluid is radially moving. The imperfect fluid and the congruence described by its four-velocity, as seen by the tilted observer, is studied in detail. It is shown that from the point of view of such tilted observer, the fluid evolves nonreversibly (i.e. with nonvanishing rate of entropy production). The nongeodesic character of the tilted congruence is related to the nonvanishing of the divergence of the 4-vector entropy flow. We determine the factor related to the existence of energy-density inhomogeneities and describe its evolution; these results are compared with those obtained for the nontilted observer. Finally, we exhibit a peculiar situation where the nontilted congruence might be unstable.

  10. On the diversity and statistical properties of protostellar discs

    Science.gov (United States)

    Bate, Matthew R.

    2018-04-01

    We present results from the first population synthesis study of protostellar discs. We analyse the evolution and properties of a large sample of protostellar discs formed in a radiation hydrodynamical simulation of star cluster formation. Due to the chaotic nature of the star formation process, we find an enormous diversity of young protostellar discs, including misaligned discs, and discs whose orientations vary with time. Star-disc interactions truncate discs and produce multiple systems. Discs may be destroyed in dynamical encounters and/or through ram-pressure stripping, but reform by later gas accretion. We quantify the distributions of disc mass and radii for protostellar ages up to ≈105 yr. For low-mass protostars, disc masses tend to increase with both age and protostellar mass. Disc radii range from of order 10 to a few hundred au, grow in size on time-scales ≲ 104 yr, and are smaller around lower mass protostars. The radial surface density profiles of isolated protostellar discs are flatter than the minimum mass solar nebula model, typically scaling as Σ ∝ r-1. Disc to protostar mass ratios rarely exceed two, with a typical range of Md/M* = 0.1-1 to ages ≲ 104 yr and decreasing thereafter. We quantify the relative orientation angles of circumstellar discs and the orbit of bound pairs of protostars, finding a preference for alignment that strengths with decreasing separation. We also investigate how the orientations of the outer parts of discs differ from the protostellar and inner disc spins for isolated protostars and pairs.

  11. Queixas auditivas de disc jockeys da cidade de Recife Auditory complaints in disc jockeys in Recife

    Directory of Open Access Journals (Sweden)

    Eliza Maia de Britto Macedo

    2011-06-01

    Full Text Available OBJETIVO: investigar a ocorrência de queixas auditivas em disc jockeys da cidade de Recife/PE. MÉTODOS: foi realizada uma entrevista com 30 disc jockeys, com idade entre 19 e 28 anos, abordando informações ocupacionais, conhecimentos gerais sobre o ruído e queixas auditivas (diminuição da acuidade auditiva, desconforto a sons intensos, zumbido, sensação de ouvido abafado e otalgia. A análise foi realizada por meio de abordagem quantitativa, utilizando o teste estatístico t-student. RESULTADOS: dentre os dados mais relevantes, destacam-se: 46,7% dos disc jockeys apresentaram, espontaneamente, queixas auditivas, em especial, a diminuição da acuidade auditiva (relatada por todos os sujeitos; 14 disc jockeys (46,67% referiram desconforto a sons intensos e 13 (43,33% mencionaram zumbido. Todos afirmaram ter conhecimento sobre os riscos do ruído para a saúde auditiva, mas 76,7% não realizam qualquer medida preventiva de suas consequências. A perda auditiva foi referida pelos sujeitos como o principal risco da exposição a níveis intensos de pressão sonora. CONCLUSÃO: todos os disc jockeys apresentaram queixa de perda auditiva e, entre as demais queixas auditivas, destacaram-se o desconforto a sons intensos e o zumbido. Tendo em vista a irreversibilidade da perda auditiva induzida por elevados níveis de pressão sonora, os disc jockeys devem ser periodicamente avaliados a fim de que se confirme ou não a perda auditiva de que se queixaram e, caso ela exista, deve ser monitorada para que seja passível de intervenção pelo fonoaudiólogo. Desta forma, percebe-se a necessidade de atuação da Fonoaudiologia junto aos disc jockeys, uma vez que poder-se-á propiciar a otimização do exercício profissional com o mínimo de risco possível.PURPOSE: to investigate the occurrence of auditory complaints in disc jockeys from the city of Recife/PE. METHODS: an interview was carried through with 30 disc jockeys aged between 19 and 48 years

  12. The reports of thick discs' deaths are greatly exaggerated. Thick discs are NOT artefacts caused by diffuse scattered light

    Science.gov (United States)

    Comerón, S.; Salo, H.; Knapen, J. H.

    2018-02-01

    Recent studies have made the community aware of the importance of accounting for scattered light when examining low-surface-brightness galaxy features such as thick discs. In our past studies of the thick discs of edge-on galaxies in the Spitzer Survey of Stellar Structure in Galaxies - the S4G - we modelled the point spread function as a Gaussian. In this paper we re-examine our results using a revised point spread function model that accounts for extended wings out to more than 2\\farcm5. We study the 3.6 μm images of 141 edge-on galaxies from the S4G and its early-type galaxy extension. Thus, we more than double the samples examined in our past studies. We decompose the surface-brightness profiles of the galaxies perpendicular to their mid-planes assuming that discs are made of two stellar discs in hydrostatic equilibrium. We decompose the axial surface-brightness profiles of galaxies to model the central mass concentration - described by a Sérsic function - and the disc - described by a broken exponential disc seen edge-on. Our improved treatment fully confirms the ubiquitous occurrence of thick discs. The main difference between our current fits and those presented in our previous papers is that now the scattered light from the thin disc dominates the surface brightness at levels below μ 26 mag arcsec-2. We stress that those extended thin disc tails are not physical, but pure scattered light. This change, however, does not drastically affect any of our previously presented results: 1) Thick discs are nearly ubiquitous. They are not an artefact caused by scattered light as has been suggested elsewhere. 2) Thick discs have masses comparable to those of thin discs in low-mass galaxies - with circular velocities vc< 120 km s-1 - whereas they are typically less massive than the thin discs in high-mass galaxies. 3) Thick discs and central mass concentrations seem to have formed at the same epoch from a common material reservoir. 4) Approximately 50% of the up

  13. How do visual and postural cues combine for self-tilt perception during slow pitch rotations?

    Science.gov (United States)

    Scotto Di Cesare, C; Buloup, F; Mestre, D R; Bringoux, L

    2014-11-01

    Self-orientation perception relies on the integration of multiple sensory inputs which convey spatially-related visual and postural cues. In the present study, an experimental set-up was used to tilt the body and/or the visual scene to investigate how these postural and visual cues are integrated for self-tilt perception (the subjective sensation of being tilted). Participants were required to repeatedly rate a confidence level for self-tilt perception during slow (0.05°·s(-1)) body and/or visual scene pitch tilts up to 19° relative to vertical. Concurrently, subjects also had to perform arm reaching movements toward a body-fixed target at certain specific angles of tilt. While performance of a concurrent motor task did not influence the main perceptual task, self-tilt detection did vary according to the visuo-postural stimuli. Slow forward or backward tilts of the visual scene alone did not induce a marked sensation of self-tilt contrary to actual body tilt. However, combined body and visual scene tilt influenced self-tilt perception more strongly, although this effect was dependent on the direction of visual scene tilt: only a forward visual scene tilt combined with a forward body tilt facilitated self-tilt detection. In such a case, visual scene tilt did not seem to induce vection but rather may have produced a deviation of the perceived orientation of the longitudinal body axis in the forward direction, which may have lowered the self-tilt detection threshold during actual forward body tilt. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  15. Tilted-ring modelling of disk galaxies : Anomalous gas

    NARCIS (Netherlands)

    Jozsa, G. I. G.; Niemczyk, C.; Klein, U.; Oosterloo, T. A.

    We report our ongoing work on kinematical modelling of HI in disk galaxies. We employ our new software TiRiFiC (Tilted-Ring-Fitting-Code) in order to derive tilted-ring models by fitting artificial HI data cubes to observed ones in an automated process. With this technique we derive very reliable

  16. Mechanoreceptors in Diseased Cervical Intervertebral Disc and Vertigo.

    Science.gov (United States)

    Yang, Liang; Yang, Cheng; Pang, Xiaodong; Li, Duanming; Yang, Hong; Zhang, Xinwu; Yang, Yi; Peng, Baogan

    2017-04-15

    We collected the samples of cervical intervertebral discs from patients with vertigo to examine the distribution and types of mechanoreceptors in diseased cervical disc. The aim of this study was to determine whether mechanoreceptors are distributed more abundantly in cervical discs from patients with cervical spondylosis, and whether they are related to vertigo. Previous limited studies have found that normal cervical intervertebral discs are supplied with mechanoreceptors that have been considered responsible for proprioceptive functions. Several clinical studies have indicated that the patients with cervical spondylosis manifested significantly impaired postural control and subjective balance disturbance. We collected 77 samples of cervical discs from 62 cervical spondylosis patients without vertigo, 61 samples from 54 patients with vertigo, and 40 control samples from 8 cadaveric donors to investigate distribution of mechanoreceptors containing neurofilament (NF200) and S-100 protein immunoreactive nerve endings. The immunohistochemical investigation revealed that the most frequently encountered mechanoreceptors were the Ruffini corpuscles in all groups of cervical disc samples. They were obviously increased in the number and deeply ingrown into inner annulus fibrosus and even into nucleus pulposus in the diseased cervical discs from patients with vertigo in comparison with the discs from patients without vertigo and control discs. Only three Golgi endings were seen in the three samples from patients with vertigo. No Pacinian corpuscles were found in any samples of cervical discs. The diseased cervical discs from patients with vertigo had more abundant distribution of Ruffini corpuscles than other discs. A positive association between the increased number and ingrowth of Ruffini corpuscles in the diseased cervical disc and the incidence of vertigo in the patients with cervical spondylosis was found, which may indicate a key role of Ruffini corpuscles in the

  17. Are galaxy discs optically thick?

    International Nuclear Information System (INIS)

    Disney, Michael; Davies, Jonathan; Phillipps, Steven

    1989-01-01

    We re-examine the classical optical evidence for the low optical depths traditionally assigned to spiral discs and argue that it is highly model-dependent and unconvincing. In particular, layered models with a physically thin but optically thick dust layer behave like optically thin discs. The opposite hypotheses, that such discs are optically thick is then examined in the light of modern evidence. We find it to be consistent with the near-infrared and IRAS observations, with the surface brightnesses, with the HI and CO column densities and with the Hα measurements. (author)

  18. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  19. High-speed-rail tilt-train technology: A state-of-the-art survey. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Boon, C.J.; Hayes, W.F.; Kesler, J.K.; Whitten, B.T.

    1992-05-01

    The report presents an assessment of the technical and operational features of existing and proposed tilt-body rail passenger vehicles. Basic concepts of railroad route selection, track geometry, and curve negotiation are reviewed, and the rationale, advantages and disadvantages associated with body tilting and the techniques used to achieve body tilt are discussed. An overview of the development status and selected key characteristics of tilt technologies are presented. Issues associated with deployment and operation of tilt-body technologies in the U..S are identified and analyzed, including a review of U.S. experience to date, areas of incompatibility of foreign tilt technology with existing U.S. equipment and infrastructure, special maintenance procedures and skill requirements, and compliance with FRA and other regulations. Appendices to the report present discussions on the physics of curve negotiation for conventional and tilting vehicles, the principles of tilting and tilt control strategies and mechanisms, and a description and technical characterization of the principal tilt technologies.

  20. NEuclid: a long-range tilt-immune homodyne interferometer

    Science.gov (United States)

    Bradshaw, M. J.; Speake, C. C.

    2017-11-01

    The new Easy to Use Compact Laser Interferometric Device (nEUCLID) is a polarisation-based homodyne interferometer with substantially unequal arms that is tolerant to target mirror tilt. The design has no active components, uses standard optical components of 25 mm diameter, has a working distance of 706 mm and a reference arm-length of 21 mm. nEUCLID optics have a footprint of 210 x 190 x 180 mm, and has a tolerance to target mirror tilt of +/- 0.5 degrees, made possible by a novel new retro-reflector design [1]. nEUCLID was built to a set of specifications laid down by Airbus Defence and Space, who required a lowmass, low-power device to measure displacement with nanometre accuracy for space applications. At the University of Birmingham we have previously built a smaller, more compact tilt-insensitive homodyne interferometer - the EUCLID [2, 3, 4] - which has a working distance of 6 mm, a working range of +/- 3 mm, and a tilt range of +/- 1° [2]. We created a new optical design to allow a much larger working distance to be achieved (as discussed in Section II) and used this in a new interferometer - the nEUCLID. Section II describes the interferometer in detail; how nEUCLID is tilt insensitive, and the optical configuration. Section III states the design specifications from Airbus Defence and Space and the components used in the final design. The output interference pattern from nEUCLID, and how it has been corrected with a meniscus lens, is also discussed. In Section IV we discuss the results demonstrating the tilt immunity range, and the sensitivity of the device. Section V describes several potential applications of nEUCLID, and Section VI draws together our conclusions.

  1. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  2. Angular momentum projection of tilted axis rotating states

    Energy Technology Data Exchange (ETDEWEB)

    Oi, M; Onishi, N; Tajima, N [Tokyo Univ. (Japan); Horibata, T

    1998-03-01

    We applied an exact angular momentum projection to three dimensional cranked HFB (3d-CHFB) states. Tilted axis rotating states (TAR) and principal axis rotating states (PAR) are compared. It is shown that TAR is more adequate than PAR for description of the back bending phenomena driven by tilted rotation or wobbling motion. (author)

  3. Examination of turbine discs from nuclear power plants

    International Nuclear Information System (INIS)

    Czajkowski, C.J.; Weeks, J.R.

    1982-01-01

    Investigations were performed on a cracked turbine disc from the Cooper Nuclear Power Station, and on two failed turbine discs (governor and generator ends) from the Yankee-Rowe Nuclear Power Station. Cooper is a boiling water reactor (BWR) which went into commercial operation in July 1974, and Yankee-Rowe is a pressurized water reactor (PWR) which went into commercial operation in June 1961. Cracks were identified in the bore of the Cooper disc after 41,913 hours of operation, and the disc removed for repair. At Yankee-Rowe two discs failed after 100,000 hours of operation. Samples of the Cooper disc and both Yankee-Rowe disc (one from the governor and one from the generator end of the LP turbine) were sent to Brookhaven National Laboratory (BNL) for failure analysis

  4. Wear behaviour of the couple polyethylene Ti6Al4V: Effects of the metallic surface preparation and nitrogen implantation

    Science.gov (United States)

    Martinella, R.; Giovanardi, S.; Palombarini, G.; Corchia, M.; Delogu, P.; Giorgi, R.; Tosello, C.

    The wear behaviour improvement of the tribological couple Ti6Al4V-UHMWPE is of great interest to the medical field. Wear tests were carried out in water on a reciprocating UHMWPE annulus on implanted Ti6Al4V disc tribotestcr, with loads and velocities simulating those of hip joints. A comparison of wear behaviours was also carried out between untreated Ti6Al4V samples and Ti6Al4V subjected to a special lapping procedure. UHMWPE worn against ion-implanted and especially lapped Ti alloy showed the lowest wear rate, while, the highest (about one order of magnitude) was shown by the UHMWPE against untreated Ti6Al4V samples. XPS and AES surface analyses were carried out on metallic discs to examine the chemical composition of the surface before wear tests. Moreover depth distribution of nitrogen in implanted samples was determined using the same techniques. SEM observations displayed a polyethylene transfer film on all metallic surfaces, particularly on untreated Ti6Al4V samples. A discussion about uselessness of more conventional surface treatments for the Ti alloy is also reported.

  5. The importance of prostate bed tilt during postprostatectomy intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Bell, Linda J.; Cox, Jennifer; Eade, Thomas; Rinks, Marianne; Kneebone, Andrew

    2014-01-01

    Variations in rectal and bladder filling can create a tilt of the prostate bed, which generates the potential for a geographic miss during postprostatectomy radiotherapy. The aim of this study is to assess the effect that bladder and rectum filling has on planning target volume angle, to determine a method to assess prostate bed tilt leading to potential geographic miss, and to discuss possible implementation issues. The cone-beam computed tomography images (n = 377) of 40 patients who received postprostatectomy radiotherapy with intensity-modulated radiotherapy were reviewed. The amount of tilt in the prostate bed was defined as the angle change between 2 surgical clips, one in the upper prostate bed and another in the lower. A potential geographic miss was defined as movement of any clip of more than 1 cm in any direction or 0.5 cm posteriorly when aligned to bone anatomy. Variations in bladder and rectum size were correlated with the degree of prostate bed tilt, and the rate of potential geographic miss was determined. A possible clinical use of prostate bed tilt was then assessed for different imaging techniques. A tilt of more than 10° was seen in 20.2% of images, which resulted in a 57.9% geographic miss rate of the superior clip. When tilt remained within 10°, there was only a 9% rate of geographic miss. Potential geographic miss of the inferior surgical clip was rare, occurring in only 1.9% of all images reviewed. The most common occurrence when the prostate bed tilt increased by more than 10° was a smaller bladder and larger rectum (6.4% of all images). The most common occurrence when the prostate bed tilt decreased by more than 10° was a larger bladder and smaller rectum (1.3% of all images). Significant prostate bed tilt (>± 10°) occurred in more than 20% of images, creating a 58% rate of geographic miss. Greatest prostate bed tilt occurred when the bladder size increased or reduced by more than 2 cm or the superior rectum size increased by more

  6. The importance of prostate bed tilt during postprostatectomy intensity-modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Linda J., E-mail: Linda.Bell1@health.nsw.gov.au [Northern Sydney Cancer Centre, Radiation Oncology Department, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales (Australia); Cox, Jennifer [Northern Sydney Cancer Centre, Radiation Oncology Department, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales (Australia); Eade, Thomas; Rinks, Marianne; Kneebone, Andrew [Northern Sydney Cancer Centre, Radiation Oncology Department, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2014-10-01

    Variations in rectal and bladder filling can create a tilt of the prostate bed, which generates the potential for a geographic miss during postprostatectomy radiotherapy. The aim of this study is to assess the effect that bladder and rectum filling has on planning target volume angle, to determine a method to assess prostate bed tilt leading to potential geographic miss, and to discuss possible implementation issues. The cone-beam computed tomography images (n = 377) of 40 patients who received postprostatectomy radiotherapy with intensity-modulated radiotherapy were reviewed. The amount of tilt in the prostate bed was defined as the angle change between 2 surgical clips, one in the upper prostate bed and another in the lower. A potential geographic miss was defined as movement of any clip of more than 1 cm in any direction or 0.5 cm posteriorly when aligned to bone anatomy. Variations in bladder and rectum size were correlated with the degree of prostate bed tilt, and the rate of potential geographic miss was determined. A possible clinical use of prostate bed tilt was then assessed for different imaging techniques. A tilt of more than 10° was seen in 20.2% of images, which resulted in a 57.9% geographic miss rate of the superior clip. When tilt remained within 10°, there was only a 9% rate of geographic miss. Potential geographic miss of the inferior surgical clip was rare, occurring in only 1.9% of all images reviewed. The most common occurrence when the prostate bed tilt increased by more than 10° was a smaller bladder and larger rectum (6.4% of all images). The most common occurrence when the prostate bed tilt decreased by more than 10° was a larger bladder and smaller rectum (1.3% of all images). Significant prostate bed tilt (>± 10°) occurred in more than 20% of images, creating a 58% rate of geographic miss. Greatest prostate bed tilt occurred when the bladder size increased or reduced by more than 2 cm or the superior rectum size increased by more

  7. The effect of MEVVA ion implantation on the tribological properties of PVD-TiN films

    International Nuclear Information System (INIS)

    Manory, R.; Mollica, S.

    1998-01-01

    The present work is the first study in which the effects of metal evaporation vacuum (MEVVA) implantation are studied on TiN of the PVD type which is commercially available in Australia. The MEVVA ion implanter differs from the 'conventional' type of ion implanter in the fact that it has a high throughput of metal ions which are not mass analysed and therefore has more potential for industrial non-electronic applications. TiN-coated steel samples have been implanted with two types of species - one light and one heavy - C + and W + respectively. The samples were analysed by Rutherford backscattering (RBS) and x-ray diffraction (XRD). The tribological performance was assessed by pin-on-disc and microhardness. The results show that carbon implantation was very effective in improving the friction coefficient by the formation of a carbonaceous layer on the surface. XRD also shows formation of TiC in the near surface region. W implantation does not improve the friction coefficient but improves the lifetime of the coating. Unimplanted films fail in the pin-on-disk test after 7000 cycles, whereas implanted films are still well adhered after 18000 cycles

  8. V/STOL tilt rotor aircraft study. Volume 6: Preliminary design of a composite wing for tilt rotor research aircraft

    Science.gov (United States)

    Soule, V. A.; Badri-Nath, Y.

    1973-01-01

    The results of a study of the use of composite materials in the wing of a tilt rotor aircraft are presented. An all-metal tilt rotor aircraft was first defined to provide a basis for comparing composite with metal structure. A configuration study was then done in which the wing of the metal aircraft was replaced with composite wings of varying chord and thickness ratio. The results of this study defined the design and performance benefits obtainable with composite materials. Based on these results the aircraft was resized with a composite wing to extend the weight savings to other parts of the aircraft. A wing design was then selected for detailed structural analysis. A development plan including costs and schedules to develop this wing and incorporate it into a proposed flight research tilt rotor vehicle has been devised.

  9. Inner core tilt and polar motion

    Science.gov (United States)

    Dumberry, Mathieu; Bloxham, Jeremy

    2002-11-01

    A tilted inner core permits exchange of angular momentum between the core and the mantle through gravitational and pressure torques and, as a result, changes in the direction of Earth's axis of rotation with respect to the mantle. We have developed a model to calculate the amplitude of the polar motion that results from an equatorial torque at the inner core boundary which tilts the inner core out of alignment with the mantle. We specifically address the issue of the role of the inner core tilt in the decade polar motion known as the Markowitz wobble. We show that a decade polar motion of the same amplitude as the observed Markowitz wobble requires a torque of 1020 N m which tilts the inner core by 0.07 degrees. This result critically depends on the viscosity of the inner core; for a viscosity less than 5 × 1017 Pa s, larger torques are required. We investigate the possibility that a torque of 1020 N m with decadal periodicity can be produced by electromagnetic coupling between the inner core and torsional oscillations of the flow in the outer core. We demonstrate that a radial magnetic field at the inner core boundary of 3 to 4 mT is required to obtain a torque of such amplitude. The resulting polar motion is eccentric and polarized, in agreement with the observations. Our model suggests that equatorial torques at the inner core boundary might also excite the Chandler wobble, provided there exists a physical mechanism that can generate a large torque at a 14 month period.

  10. Analysis of rabbit intervertebral disc physiology based on water metabolism. II. Changes in normal intervertebral discs under axial vibratory load

    International Nuclear Information System (INIS)

    Hirano, N.; Tsuji, H.; Ohshima, H.; Kitano, S.; Itoh, T.; Sano, A.

    1988-01-01

    Metabolic changes induced by axial vibratory load to the spine were investigated based on water metabolism in normal intervertebral discs of rabbits with or without pentobarbital anesthesia. Tritiated water concentration in the intervertebral discs of unanesthetized rabbits was reduced remarkably by axial vibration for 30 minutes using the vibration machine developed for this study. Repeated vibratory load for 18 and 42 hours duration showed the recovery of 3 H 2 O concentration of the intervertebral disc without anesthesia. Computer simulation suggested a reduction of blood flow surrounding the intervertebral disc following the vibration stress. However, no reduction of the 3 H 2 O concentration in the intervertebral disc was noted under anesthesia. Emotional stress cannot be excluded as a factor in water metabolism in the intervertebral disc

  11. INJURIES IN DISC GOLF - A DESCRIPTIVE CROSS-SECTIONAL STUDY

    DEFF Research Database (Denmark)

    Rahbek, Martin Amadeus; Nielsen, Rasmus Oestergaard

    2016-01-01

    BACKGROUND: Disc golf is rapidly increasing in popularity and more than two million people are estimated to regularly participate in disc golf activities. Despite this popularity, the epidemiology of injuries in disc golf remains under reported. PURPOSE: The purpose of the present study...... was to investigate the prevalence and anatomic distribution of injuries acquired through disc-golf participation in Danish disc golf players. METHODS: The study was a cross-sectional study conducted on Danish disc-golf players. In May 2015, invitations to complete a web-based questionnaire were spread online via...... social media, and around disc-golf courses in Denmark. The questionnaire included questions regarding disc-golf participation and the characteristics of injuries acquired through disc golf participation. The data was analyzed descriptively. RESULTS: An injury prevalence of 13.3% (95% CI: 6.7% to 19...

  12. Simultaneous determination of sample thickness, tilt, and electron mean free path using tomographic tilt images based on Beer-Lambert law.

    Science.gov (United States)

    Yan, Rui; Edwards, Thomas J; Pankratz, Logan M; Kuhn, Richard J; Lanman, Jason K; Liu, Jun; Jiang, Wen

    2015-11-01

    Cryo-electron tomography (cryo-ET) is an emerging technique that can elucidate the architecture of macromolecular complexes and cellular ultrastructure in a near-native state. Some important sample parameters, such as thickness and tilt, are needed for 3-D reconstruction. However, these parameters can currently only be determined using trial 3-D reconstructions. Accurate electron mean free path plays a significant role in modeling image formation process essential for simulation of electron microscopy images and model-based iterative 3-D reconstruction methods; however, their values are voltage and sample dependent and have only been experimentally measured for a limited number of sample conditions. Here, we report a computational method, tomoThickness, based on the Beer-Lambert law, to simultaneously determine the sample thickness, tilt and electron inelastic mean free path by solving an overdetermined nonlinear least square optimization problem utilizing the strong constraints of tilt relationships. The method has been extensively tested with both stained and cryo datasets. The fitted electron mean free paths are consistent with reported experimental measurements. The accurate thickness estimation eliminates the need for a generous assignment of Z-dimension size of the tomogram. Interestingly, we have also found that nearly all samples are a few degrees tilted relative to the electron beam. Compensation of the intrinsic sample tilt can result in horizontal structure and reduced Z-dimension of tomograms. Our fast, pre-reconstruction method can thus provide important sample parameters that can help improve performance of tomographic reconstruction of a wide range of samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Magnetic resonance imaging in cadaver dogs with metallic vertebral implants at 3 Tesla: evaluation of the WARP-turbo spin echo sequence.

    Science.gov (United States)

    Griffin, John F; Archambault, Nicholas S; Mankin, Joseph M; Wall, Corey R; Thompson, James A; Padua, Abraham; Purdy, David; Kerwin, Sharon C

    2013-11-15

    Laboratory investigation, ex vivo. Postoperative complications are common after spinal implantation procedures, and magnetic resonance imaging (MRI) would be the ideal modality to image these patients. Unfortunately, the implants cause artifacts that can render MRI nondiagnostic. The WARP-turbo spin echo (TSE) sequence has been developed to mitigate artifacts caused by metal. The objective of this investigation was to evaluate the performance of the WARP-TSE sequence in canine cadaver specimens after implantation with metallic vertebral implants. Magnetic field strength, implant type, and MRI acquisition technique all play a role in the severity of susceptibility artifacts. The WARP-TSE sequence uses increased bandwidth, view angle tilting, and SEMAC (slice-encoding metal artifact correction) to correct for susceptibility artifact. The WARP-TSE technique has outperformed conventional techniques in patients, after total hip arthroplasty. However, published reports of its application in subjects with vertebral column implants are lacking. Ex vivo anterior stabilization of the atlantoaxial joint was performed on 6 adult small breed (implantation with stainless steel implants. N/A.

  14. Hydrodynamic forces on two moving discs

    Directory of Open Access Journals (Sweden)

    Burton D.A.

    2004-01-01

    Full Text Available We give a detailed presentation of a flexible method for constructing explicit expressions of irrotational and incompressible fluid flows around two rigid circular moving discs. We also discuss how such expressions can be used to compute the fluid-induced forces and torques on the discs in terms of Killing drives. Conformal mapping techniques are used to identify a meromorphic function on an annular region in C with a flow around two circular discs by a Mobius transformation. First order poles in the annular region correspond to vortices outside of the two discs. Inflows are incorporated by putting a second order pole at the point in the annulus that corresponds to infinity.

  15. Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

    Science.gov (United States)

    Wood, S. J.; Rupert, A. H.; Vanya, R. D.; Esteves, J. T.; Clement, G.

    2011-01-01

    We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.

  16. Novel tilt-curvature coupling in lipid membranes

    Science.gov (United States)

    Terzi, M. Mert; Deserno, Markus

    2017-08-01

    On mesoscopic scales, lipid membranes are well described by continuum theories whose main ingredients are the curvature of a membrane's reference surface and the tilt of its lipid constituents. In particular, Hamm and Kozlov [Eur. Phys. J. E 3, 323 (2000)] have shown how to systematically derive such a tilt-curvature Hamiltonian based on the elementary assumption of a thin fluid elastic sheet experiencing internal lateral pre-stress. Performing a dimensional reduction, they not only derive the basic form of the effective surface Hamiltonian but also express its emergent elastic couplings as trans-membrane moments of lower-level material parameters. In the present paper, we argue, though, that their derivation unfortunately missed a coupling term between curvature and tilt. This term arises because, as one moves along the membrane, the curvature-induced change of transverse distances contributes to the area strain—an effect that was believed to be small but nevertheless ends up contributing at the same (quadratic) order as all other terms in their Hamiltonian. We illustrate the consequences of this amendment by deriving the monolayer and bilayer Euler-Lagrange equations for the tilt, as well as the power spectra of shape, tilt, and director fluctuations. A particularly curious aspect of our new term is that its associated coupling constant is the second moment of the lipid monolayer's lateral stress profile—which within this framework is equal to the monolayer Gaussian curvature modulus, κ¯ m. On the one hand, this implies that many theoretical predictions now contain a parameter that is poorly known (because the Gauss-Bonnet theorem limits access to the integrated Gaussian curvature); on the other hand, the appearance of κ¯ m outside of its Gaussian curvature provenance opens opportunities for measuring it by more conventional means, for instance by monitoring a membrane's undulation spectrum at short scales.

  17. SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER

    International Nuclear Information System (INIS)

    QIAN, S.; QIAN, K.; HONG, Y.; SENG, L.; HO, T.; TAKACS, P.

    2007-01-01

    Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately

  18. Effect of Interbody Fusion on the Remaining Discs of the Lumbar Spine in Subjects with Disc Degeneration.

    Science.gov (United States)

    Ryu, Robert; Techy, Fernando; Varadarajan, Ravikumar; Amirouche, Farid

    2016-02-01

    To study effects (stress loads) of lumbar fusion on the remaining segments (adjacent or not) of the lumbar spine in the setting of degenerated adjacent discs. A lumbar spine finite element model was built and validated. The full model of the lumbar spine was a parametric finite element model of segments L 1-5 . Numerous hypothetical combinations of one-level lumbar spine fusion and one-level disc degeneration were created. These models were subjected to 10 Nm flexion and extension moments and the stresses on the endplates and consequently on the intervertebral lumbar discs measured. These values were compared to the stresses on healthy lumbar spine discs under the same load and fusion scenarios. Increased stress at endplates was observed only in the settings of L4-5 fusion and L3-4 disc degeneration (8% stress elevation at L2,3 in flexion or extension, and 25% elevation at L3,4 in flexion only). All other combinations showed less endplate stress than did the control model. For fusion at L3-4 and degeneration at L4-5 , the stresses in the endplates at the adjacent level inferior to the fused disc decreased for both loading disc height reductions. Stresses in flexion decreased after fusion by 29.5% and 25.8% for degeneration I and II, respectively. Results for extension were similar. For fusion at L2-3 and degeneration at L4-5 , stresses in the endplates decreased more markedly at the degenerated (30%), than at the fused level (14%) in the presence of 25% disc height reduction and 10 Nm flexion, whereas in extension stresses decreased more at the fused (24.3%) than the degenerated level (5.86%). For fusion at L3-4 and degeneration at L2-3 , there were no increases in endplate stress in any scenario. For fusion at L4-5 and degeneration at L3-4 , progression of degeneration from I to II had a significant effect only in flexion. A dramatic increase in stress was noted in the endplates of the degenerated disc (L3-4 ) in flexion for degeneration II. Stresses are greater

  19. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.

    Science.gov (United States)

    Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton

    2015-02-01

    The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and

  20. Modulation of internal estimates of gravity during and after prolonged roll-tilts.

    Directory of Open Access Journals (Sweden)

    Alexander A Tarnutzer

    Full Text Available Perceived direction of gravity, as assessed by the subjective visual vertical (SVV, shows roll-angle dependent errors that drift over time and a bias upon return to upright. According to Bayesian observer theory, the estimated direction of gravity is derived from the posterior probability distribution by combining sensory input and prior knowledge about earth-vertical in a statistically optimal fashion. Here we aimed to further characterize the stability of SVV during and after prolonged roll-tilts. Specifically we asked whether the post-tilt bias is related to the drift pattern while roll-tilted. Twenty-nine healthy human subjects (23-56 yo repetitively adjusted a luminous arrow to the SVV over periods of 5 min while upright, roll-tilted (± 45°, ± 90°, and immediately after returning to upright. Significant (p<0.05 drifts (median absolute drift-amplitude: 10°/5 min were found in 71% (± 45° and 78% (± 90° of runs. At ± 90° roll-tilt significant increases in absolute adjustment errors were more likely (76%, whereas significant increases (56% and decreases (44% were about equally frequent at ± 45°. When returning to upright, an initial bias towards the previous roll-position followed by significant exponential decay (median time-constant: 71 sec was noted in 47% of all runs (all subjects pooled. No significant correlations were found between the drift pattern during and immediately after prolonged roll-tilt. We conclude that the SVV is not stable during and after prolonged roll-tilt and that the direction and magnitude of drift are individually distinct and roll-angle-dependent. Likely sensory and central adaptation and random-walk processes contribute to drift while roll-tilted. Lack of correlation between the drift and the post-tilt bias suggests that it is not the inaccuracy of the SVV estimate while tilted that determines post-tilt bias, but rather the previous head-roll orientation relative to gravity. We therefore favor central

  1. Spondylolisthesis adjacent to a cervical disc arthroplasty does not increase the risk of adjacent level degeneration.

    Science.gov (United States)

    Kieser, David Christopher; Cawley, Derek Thomas; Roscop, Cecile; Mazas, Simon; Coudert, Pierre; Boissiere, Louis; Obeid, Ibrahim; Vital, Jean-Marc; Pointillart, Vincent; Gille, Olivier

    2018-03-31

    To understand whether a spondylolisthesis in the sub-axial spine cranial to a cervical disc arthroplasty (CDA) construes a risk of adjacent level disease (ALD). A retrospective review of 164 patients with a minimum 5-year follow-up of a cervical disc arthroplasty was performed. Multi-level surgeries, including hybrid procedures, were included. Multiple implant types were included. The two inter-vertebral discs (IVD) cranial of the CDA were monitored for evidence of radiologic degeneration using the Kettler criteria. The rate of ALD in CDA found in this series was 17.8%, with most affecting the immediately adjacent IVD (27.4 and 7.6%, respectively p = 0.000). Pre-operative mild spondylolisthesis adjacent to a planned CDA was not found to be a risk factor for ALD within 5 years. Those with a degenerative spondylolisthesis are at higher risk of ALD (33%) than those with a non-degenerative cause for their spondylolisthesis (11%). Post-operative CDA alignment, ROM or induced spondylolisthesis do not affect the rate of ALD in those with an adjacent spondylolisthesis. Patients with ALD experience significantly worse 5-year pain and functional outcomes than those unaffected by ALD. A pre-operatively identified mild spondylolisthesis in the sub-axial spine cranially adjacent to a planned CDA is not a risk factor for ALD within 5 years. These slides can be retrieved under Electronic Supplementary Material.

  2. Effects of external feedback about body tilt: Influence on the Subjective Proprioceptive Horizon.

    Science.gov (United States)

    Bringoux, L; Bourdin, C; Nougier, V; Raphel, C

    2006-11-06

    The present study investigated a cognitive aspect upon spatial perception, namely the impact of a true or false verbal feedback (FB) about the magnitude of body tilt on Subjective Proprioceptive Horizon (SPH) estimates. Subjects were asked to set their extended arm normal to gravity for different pitch body tilts up to 9 degrees . True FB were provided at all body tilt angles, whereas false FB were provided only at 6 degrees backward and 6 degrees forward body tilts for half of the trials. Our data confirmed previous results about the egocentric influence of body tilt itself upon SPH: estimates were linearly lowered with forward tilts and elevated with backward tilts. In addition, results showed a significant effect of the nature of the external FB provided to the subjects. When subjects received a false FB inducing a 3 degrees forward bias relative to physical body tilt, they set their SPH consequently higher than when they received a false FB inducing a 3 degrees backward bias. These findings clearly indicated that false cognitive information about body tilt might significantly modify the judgement of a geocentric direction of space, such as the SPH. This may have deleterious repercussions in aeronautics when pilots have to localize external objects relative to earth-based directions in darkened environments.

  3. Research on calculation of the IOL tilt and decentration based on surface fitting.

    Science.gov (United States)

    Li, Lin; Wang, Ke; Yan, Yan; Song, Xudong; Liu, Zhicheng

    2013-01-01

    The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the anterior and posterior surfaces of the IOL. By the established relationship between IOL tilt (decentration) and the scanned angle, at which a piece of AS-OCT image was taken by the instrument, the IOL tilt and decentration were calculated. IOL tilt angle and decentration of each subject were given. Moreover, the horizontal and vertical tilt was also obtained. Accordingly, the possible errors of IOL tilt and decentration existed in the method employed by AS-OCT instrument. Based on 6-12 pieces of AS-OCT images at different directions, the tilt angle and decentration values were shown, respectively. The method of the surface fitting to the IOL surface can accurately analyze the IOL's location, and six pieces of AS-OCT images at three pairs symmetrical directions are enough to get tilt angle and decentration value of IOL more precisely.

  4. Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting

    Directory of Open Access Journals (Sweden)

    Lin Li

    2013-01-01

    Full Text Available The tilt and decentration of intraocular lens (IOL result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the anterior and posterior surfaces of the IOL. By the established relationship between IOL tilt (decentration and the scanned angle, at which a piece of AS-OCT image was taken by the instrument, the IOL tilt and decentration were calculated. IOL tilt angle and decentration of each subject were given. Moreover, the horizontal and vertical tilt was also obtained. Accordingly, the possible errors of IOL tilt and decentration existed in the method employed by AS-OCT instrument. Based on 6–12 pieces of AS-OCT images at different directions, the tilt angle and decentration values were shown, respectively. The method of the surface fitting to the IOL surface can accurately analyze the IOL’s location, and six pieces of AS-OCT images at three pairs symmetrical directions are enough to get tilt angle and decentration value of IOL more precisely.

  5. Magnetic domain-wall tilting due to domain-wall speed asymmetry

    Science.gov (United States)

    Kim, Dae-Yun; Park, Min-Ho; Park, Yong-Keun; Kim, Joo-Sung; Nam, Yoon-Seok; Hwang, Hyun-Seok; Kim, Duck-Ho; Je, Soong-Geun; Min, Byoung-Chul; Choe, Sug-Bong

    2018-04-01

    Broken symmetries in diverse systems generate a number of intriguing phenomena and the analysis on such broken symmetries often provides decisive clues for exploring underlying physics in the systems. Recently, in magnetic thin-film systems, the Dzyaloshinskii-Moriya interaction (DMI)—induced by the broken symmetry of structural inversion—accounts for various chiral phenomena, which are of timely issues in spintronics. Here, we report an experimental observation on unexpected tilting of magnetic domain walls (DWs) due to the broken symmetry under the application of the magnetic field transverse to the magnetic wire systems. It has been predicted that the DMI possibly causes such DW tilting in the direction of the energy minimization. However, very interestingly, experimental observation reveals that the DW tilting does not follow the prediction based on the energy minimization, even for the tilting direction. Instead, the DW tilting is governed by the DW speed asymmetry that is initiated by the DW pinning at wire edges. A simple analytic model is proposed in consideration of the DW speed asymmetry at wire edges, which successfully explains the experimental observation of the DW tilting directions and angles, as confirmed by numerical simulation. The present study manifests the decisive role of the DW pinning with the DW speed asymmetry, which determines the DW configuration and consequently, the dynamics.

  6. Mechanisms of Günther Tulip filter tilting during transfemoral placement.

    Science.gov (United States)

    Matsui, Y; Horikawa, M; Ohta, K; Jahangiri Noudeh, Y; Kaufman, J A; Farsad, K

    The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  7. Mechanical design criteria for intervertebral disc tissue engineering.

    Science.gov (United States)

    Nerurkar, Nandan L; Elliott, Dawn M; Mauck, Robert L

    2010-04-19

    Due to the inability of current clinical practices to restore function to degenerated intervertebral discs, the arena of disc tissue engineering has received substantial attention in recent years. Despite tremendous growth and progress in this field, translation to clinical implementation has been hindered by a lack of well-defined functional benchmarks. Because successful replacement of the disc is contingent upon replication of some or all of its complex mechanical behaviors, it is critically important that disc mechanics be well characterized in order to establish discrete functional goals for tissue engineering. In this review, the key functional signatures of the intervertebral disc are discussed and used to propose a series of native tissue benchmarks to guide the development of engineered replacement tissues. These benchmarks include measures of mechanical function under tensile, compressive, and shear deformations for the disc and its substructures. In some cases, important functional measures are identified that have yet to be measured in the native tissue. Ultimately, native tissue benchmark values are compared to measurements that have been made on engineered disc tissues, identifying where functional equivalence was achieved, and where there remain opportunities for advancement. Several excellent reviews exist regarding disc composition and structure, as well as recent tissue engineering strategies; therefore this review will remain focused on the functional aspects of disc tissue engineering. Copyright 2009 Elsevier Ltd. All rights reserved.

  8. Numerical modelling of the tilt casting processes of titanium alumindes

    OpenAIRE

    Wang, Hong

    2008-01-01

    This research has investigated the modelling and optimisation of the tilt casting process of Titanium Aluminides (TiAl). This study is carried out in parallel with the experimental research undertaken in IRC at the University of Birmingham. They propose to use tilt casting inside a vacuum chamber and attempt to combine this tilt casting process with Induction Skull Melting (ISM). A totally novel process is developing for investment casting, which is suitable for casting gamma TiAl.\\ud \\ud As ...

  9. Tilting-connected symmetric algebras

    OpenAIRE

    Aihara, Takuma

    2010-01-01

    The notion of silting mutation was introduced by Iyama and the author. In this paper we mainly study silting mutation for self-injective algebras and prove that any representation-finite symmetric algebra is tilting-connected. Moreover we give some sufficient conditions for a Bongartz-type Lemma to hold for silting objects.

  10. Rigidity of tilting modules

    DEFF Research Database (Denmark)

    Haahr Andersen, Henning; Kaneda, Masaharu

    Let $U_q$ denote the quantum group associated with a finite dimensional semisimple Lie algebra. Assume that $q$ is a complex root of unity of odd order and that $U_q$ is %the quantum group version obtained via Lusztig's $q$-divided powers construction. We prove that all regular projective (tilting...

  11. [Atypical sinus node dysfunction. Usefulness of implantable Holter. A case report].

    Science.gov (United States)

    Martí Almor, J; Delclòs Urgell, J; Bruguera Cortada, J

    2001-12-01

    We present an 84 year-old female patient with repeated syncopes/presyncopes in the last nine years. All diagnosis tests were negative, including ECG, 24-hour Holter, tilt table test and EP study. Therefore, a subcutaneous insertable loop recorder was implanted (Reveal). The recording of three episodes showed the association of presyncope with the onset of atrial fibrilation and, in two syncopes, with an atrial pause between AF episodes. Probably an abnormal prolonged sinus node recovery time (more than 6 s) allowed AF to restart before the sinus rhythm.

  12. Velocity dependence of vestibular information for postural control on tilting surfaces

    Science.gov (United States)

    Kluzik, JoAnn; Hlavacka, Frantisek

    2016-01-01

    Vestibular information is known to be important for postural stability on tilting surfaces, but the relative importance of vestibular information across a wide range of surface tilt velocities is less clear. We compared how tilt velocity influences postural orientation and stability in nine subjects with bilateral vestibular loss and nine age-matched, control subjects. Subjects stood on a force platform that tilted 6 deg, toes-up at eight velocities (0.25 to 32 deg/s), with and without vision. Results showed that visual information effectively compensated for lack of vestibular information at all tilt velocities. However, with eyes closed, subjects with vestibular loss were most unstable within a critical tilt velocity range of 2 to 8 deg/s. Subjects with vestibular deficiency lost their balance in more than 90% of trials during the 4 deg/s condition, but never fell during slower tilts (0.25–1 deg/s) and fell only very rarely during faster tilts (16–32 deg/s). At the critical velocity range in which falls occurred, the body center of mass stayed aligned with respect to the surface, onset of ankle dorsiflexion was delayed, and there was delayed or absent gastrocnemius inhibition, suggesting that subjects were attempting to actively align their upper bodies with respect to the moving surface instead of to gravity. Vestibular information may be critical for stability at velocities of 2 to 8 deg/s because postural sway above 2 deg/s may be too fast to elicit stabilizing responses through the graviceptive somatosensory system, and postural sway below 8 deg/s may be too slow for somatosensory-triggered responses or passive stabilization from trunk inertia. PMID:27486101

  13. Locally prepared antibiotic sensitivity discs: a substitute for imported ...

    African Journals Online (AJOL)

    Zones of inhibition were compared with those obtained from commercial antibiotic discs. Results obtained showed that discs prepared locally from antibiotic tablets, performed comparably with commercially obtained discs. There was no significant statistical difference between the two tested discs. We therefore recommend ...

  14. Imaging characteristics of noncontained migrating disc fragment and cyst

    International Nuclear Information System (INIS)

    Eerens, I.; Demaerel, P.; Haven, F.; Wilms, G.; Loon, J. van; Calenbergh, F. van

    2001-01-01

    The purpose of this article is to review less common presentations of degenerative disc disease on MR imaging. The images of eight patients were retrospectively analyzed. Six of them had transligamentous (or noncontained) disc herniations, the fragments of which were located in the posterior epidural space in three of them. One patient had a transdural disc fragment and one patient had a disc cyst. The cyst was located in the ventrolateral epidural space. On T2-weighted images, the migrated disc fragment returned a higher signal than the disc of origin in 6 of 7 patients. The disc cyst returned a signal similar to that of cerebrospinal fluid. The MR appearances of disc fragments can be puzzling, particularly if they are located in the posterior epidural space. It is important to recognize the abnormalities in order to differentiate them from less common lesions such as hematoma, abscess and neurinoma. (orig.)

  15. Imaging characteristics of noncontained migrating disc fragment and cyst

    Energy Technology Data Exchange (ETDEWEB)

    Eerens, I.; Demaerel, P.; Haven, F.; Wilms, G. [Dept. of Radiology, University Hospitals, Leuven (Belgium); Loon, J. van; Calenbergh, F. van [Dept. of Neurosurgery, University Hospitals, Leuven (Belgium)

    2001-05-01

    The purpose of this article is to review less common presentations of degenerative disc disease on MR imaging. The images of eight patients were retrospectively analyzed. Six of them had transligamentous (or noncontained) disc herniations, the fragments of which were located in the posterior epidural space in three of them. One patient had a transdural disc fragment and one patient had a disc cyst. The cyst was located in the ventrolateral epidural space. On T2-weighted images, the migrated disc fragment returned a higher signal than the disc of origin in 6 of 7 patients. The disc cyst returned a signal similar to that of cerebrospinal fluid. The MR appearances of disc fragments can be puzzling, particularly if they are located in the posterior epidural space. It is important to recognize the abnormalities in order to differentiate them from less common lesions such as hematoma, abscess and neurinoma. (orig.)

  16. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  17. Thoracic spine disc-related abnormalities: longitudinal MR imaging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Girard, Charles J.; Schweitzer, Mark E.; Morrison, William B.; Parellada, Joan A. [TJUH Radiology, Philadelphia, Pennsylvania (United States); Carrino, J.A. [Department of Radiology ASB-1, Harvard Medical School, Brigham and Women' s Hospital, L1, Room 002B, 75 Francis Street, MA 02115, Boston (United States)

    2004-04-01

    To describe and characterize the temporal changes in disc-related disorders of the thoracic spine using MR imaging. A retrospective longitudinal cohort study was carried out of 40 patients with two sequential thoracic spine MR images at variable intervals. The images were assessed for baseline presence of, new incidence of and changes in disc herniation, degenerative disc disease, endplate marrow signal alteration and Schmorl nodes. The range of follow-up was 4-149 weeks. Baseline presence was: disc herniation, 10% (49/480); degenerative disc disease, 14% (66/480); endplate marrow signal alteration, 2.3% (11/480); Schmorl nodes 9.6% (46/480). Most pre-existing lesions tended to remain unchanged. Herniations showed the most change, tending to improve in 27%. New incidence was: disc herniation, 1.5% (7/480), degenerative disc disease, 2% (10/480); endplate marrow signal alteration, 1.6% (8/480); Schmorl nodes, 2.1% (10/480). Disc degeneration was first visible at an 11-week interval and once established almost never changed over many weeks to months. Endplate signal alterations (Modic changes) were uncommon. Schmorl nodes show no change from baseline for up to 2 1/2 years. All findings predominated in the lower intervertebral levels from T6 to T10. The most prevalent thoracic spine disc-related findings are degeneration and herniation. Disc herniations predominate in the lower segments and are a dynamic phenomenon. Disc degeneration can be rapidly evolving but tends to remain unchanged after occurrence. Endplate marrow signal changes were an uncommon manifestation of thoracic disc disease. Schmorl nodes showed the least change over time. (orig.)

  18. Use NASA GES DISC Data in ArcGIS

    Science.gov (United States)

    Yang, Wenli; Pham, Long B.; Kempler, Steve

    2015-01-01

    This presentation describes GIS relevant data at NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), GES DISC Services and Support for GIS Users, and use cases of GES DISC data in ArcGIS.

  19. The formation of planets by disc fragmentation

    Directory of Open Access Journals (Sweden)

    Stamatellos Dimitris

    2013-04-01

    Full Text Available I discuss the role that disc fragmentation plays in the formation of gas giant and terrestrial planets, and how this relates to the formation of brown dwarfs and low-mass stars, and ultimately to the process of star formation. Protostellar discs may fragment, if they are massive enough and can cool fast enough, but most of the objects that form by fragmentation are brown dwarfs. It may be possible that planets also form, if the mass growth of a proto-fragment is stopped (e.g. if this fragment is ejected from the disc, or suppressed and even reversed (e.g by tidal stripping. I will discuss if it is possible to distinguish whether a planet has formed by disc fragmentation or core accretion, and mention of a few examples of observed exoplanets that are suggestive of formation by disc fragmentation.

  20. Senescent intervertebral disc cells exhibit perturbed matrix homeostasis phenotype.

    Science.gov (United States)

    Ngo, Kevin; Patil, Prashanti; McGowan, Sara J; Niedernhofer, Laura J; Robbins, Paul D; Kang, James; Sowa, Gwendolyn; Vo, Nam

    2017-09-01

    Aging greatly increases the risk for intervertebral disc degeneration (IDD) as a result of proteoglycan loss due to reduced synthesis and enhanced degradation of the disc matrix proteoglycan (PG). How disc matrix PG homeostasis becomes perturbed with age is not known. The goal of this study is to determine whether cellular senescence is a source of this perturbation. We demonstrated that disc cellular senescence is dramatically increased in the DNA repair-deficient Ercc1 -/Δ mouse model of human progeria. In these accelerated aging mice, increased disc cellular senescence is closely associated with the rapid loss of disc PG. We also directly examine PG homeostasis in oxidative damage-induced senescent human cells using an in vitro cell culture model system. Senescence of human disc cells treated with hydrogen peroxide was confirmed by growth arrest, senescence-associated β-galactosidase activity, γH2AX foci, and acquisition of senescence-associated secretory phenotype. Senescent human disc cells also exhibited perturbed matrix PG homeostasis as evidenced by their decreased capacity to synthesize new matrix PG and enhanced degradation of aggrecan, a major matrix PG. of the disc. Our in vivo and in vitro findings altogether suggest that disc cellular senescence is an important driver of PG matrix homeostatic perturbation and PG loss. Published by Elsevier B.V.

  1. Ambiguous Tilt and Translation Motion Cues in Astronauts after Space Flight

    Science.gov (United States)

    Clement, G.; Harm, D. L.; Rupert, A. H.; Beaton, K. H.; Wood, S. J.

    2008-01-01

    Adaptive changes during space flight in how the brain integrates vestibular cues with visual, proprioceptive, and somatosensory information can lead to impaired movement coordination, vertigo, spatial disorientation, and perceptual illusions following transitions between gravity levels. This joint ESA-NASA pre- and post-flight experiment is designed to examine both the physiological basis and operational implications for disorientation and tilt-translation disturbances in astronauts following short-duration space flights. The first specific aim is to examine the effects of stimulus frequency on adaptive changes in eye movements and motion perception during independent tilt and translation motion profiles. Roll motion is provided by a variable radius centrifuge. Pitch motion is provided by NASA's Tilt-Translation Sled in which the resultant gravitoinertial vector remains aligned with the body longitudinal axis during tilt motion (referred to as the Z-axis gravitoinertial or ZAG paradigm). We hypothesize that the adaptation of otolith-mediated responses to these stimuli will have specific frequency characteristics, being greatest in the mid-frequency range where there is a crossover of tilt and translation. The second specific aim is to employ a closed-loop nulling task in which subjects are tasked to use a joystick to null-out tilt motion disturbances on these two devices. The stimuli consist of random steps or sum-of-sinusoids stimuli, including the ZAG profiles on the Tilt-Translation Sled. We hypothesize that the ability to control tilt orientation will be compromised following space flight, with increased control errors corresponding to changes in self-motion perception. The third specific aim is to evaluate how sensory substitution aids can be used to improve manual control performance. During the closed-loop nulling task on both devices, small tactors placed around the torso vibrate according to the actual body tilt angle relative to gravity. We hypothesize

  2. Intervertebral Disc Characteristic on Progressive Neurological Deficit

    Directory of Open Access Journals (Sweden)

    Farid Yudoyono

    2017-09-01

    Full Text Available Objective: To examine the intervertebral disc characteristic on magnetic resonance imaging (MRI in lumbar herniated disc (LHD patients with progressive neurological deficit. Methods: Patients were collected retrospectively from Dr. Hasan Sadikin General Hospital Database from 2011–2013 with LHD, had neurological deficit such as radiculopathy and cauda equine syndrome for less than four weeks with a positive sign confirmed by neurological examination and confirmatory with MRI examination. Results: A total of 14 patients with lumbar herniated disc disease (10 males, 4 females suffered from progressive neurological deficit with an average age of (52.07±10.9 years old. Early disc height was 9.38±0.5 mm and progressive neurological deficit state disc height was 4.03±0.53 mm, which were significantly different statisticaly (p<0.01. Symptoms of radiculopathy were seen in 11 patients and cauda equine syndrome in three patients. Modic changes grade 1 was found in five patients, grade 2 in eight patients,grade 3 in one patient, Pfirmman grade 2 in eleven patients and grade 3 in three patients. Thecal sac compression 1/3 compression was seen in four patients and 2/3 compression in ten patients. Conclusions: Neurosurgeon should raise concerns on the characteristic changes of intervertebral disc in magnetic resonance imaging examination to avoid further neural injury in lumbar herniated disc patients.

  3. Head tilt produced by hemilabyrinthectomy does not depend on the direct vestibulospinal tracts.

    Science.gov (United States)

    Fukushima, K; Fukushima, J; Kato, M

    1988-01-01

    Head tilt is one of the most characteristic and enduring symptoms produced by hemilabyrinthectomy and is compensated by the central nervous system with time. In order to study the central mechanisms of compensation of the head tilt, it is first necessary to understand how it is produced. However, its mechanism remains unknown. Experiments were performed in cats to examine whether the direct vestibulocollic pathways are responsible for the head tilt, as suggested by some authors. Hemilabyrinthectomies produced a characteristic head tilt in cats in which the medial and/or one lateral vestibulospinal tracts (VSTs) had been interrupted. The lesions of the medial VST did not influence the preexisting head tilt produced by hemilabyrinthectomies. These results suggest that the head tilt produced by hemilabyrinthectomies does not depend on the activity of the VSTs.

  4. Low-intensity pulsed ultrasound enhances bone formation around miniscrew implants.

    Science.gov (United States)

    Ganzorig, Khaliunaa; Kuroda, Shingo; Maeda, Yuichi; Mansjur, Karima; Sato, Minami; Nagata, Kumiko; Tanaka, Eiji

    2015-06-01

    Miniscrew implants (MSIs) are currently used to provide absolute anchorage in orthodontics; however, their initial stability is an issue of concern. Application of low-intensity pulsed ultrasound (LIPUS) can promote bone healing. Therefore, LIPUS application may stimulate bone formation around MSIs and enhance their initial stability. To investigate the effect of LIPUS exposure on bone formation after implantation of titanium (Ti) and stainless steel (SS) MSIs. MSIs made of Ti-6Al-4V and 316L SS were placed on rat tibiae and treated with LIPUS. The bone morphology around MSIs was evaluated by scanning electron microscopy and three-dimensional micro-computed tomography. MC3T3-E1 cells cultured on Ti and SS discs were treated with LIPUS, and the temporary expression of alkaline phosphatase (ALP) was examined. Bone-implant contact increased gradually from day 3 to day 14 after MSI insertion. LIPUS application increased the cortical bone density, cortical bone thickness, and cortical bone rate after implantation of Ti and SS MSIs (P<0.05). LIPUS exposure induced ALP upregulation in MC3T3-E1 cells at day 3 (P<0.05). LIPUS enhanced bone formation around Ti and SS MSIs, enhancing the initial stability of MSIs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Modeling Flow Past a Tilted Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L

    2009-06-29

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside a model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.

  6. A wide-field suprachoroidal retinal prosthesis is stable and well tolerated following chronic implantation.

    Science.gov (United States)

    Villalobos, Joel; Nayagam, David A X; Allen, Penelope J; McKelvie, Penelope; Luu, Chi D; Ayton, Lauren N; Freemantle, Alexia L; McPhedran, Michelle; Basa, Meri; McGowan, Ceara C; Shepherd, Robert K; Williams, Chris E

    2013-05-01

    The safety of chronic implantation of a retinal prosthesis in the suprachoroidal space has not been established. This study aimed to determine the safety of a wide-field suprachoroidal electrode array following chronic implantation using histopathologic techniques and electroretinography. A platinum electrode array in a wide silicone substrate was implanted unilaterally in the suprachoroidal space in adult cats (n = 7). The lead and connector were tunneled out of the orbit and positioned subcutaneously. Postsurgical recovery was assessed using fundus photography and electroretinography (ERG). Following 3 months of passive implantation, the animals were terminated and the eyes assessed for the pathologic response to implantation. The implant was mechanically stable in the suprachoroidal space during the course of the study. The implanted eye showed a transient increase in ERG response amplitude at 2 weeks, which returned to normal by 3 months. Pigmentary changes were observed at the distal end of the implant, near the optic disc. Histopathologic assessment revealed a largely intact retina and a thin fibrous capsule around the suprachoroidal implant cavity. The foreign body response was minimal, with sporadic presence of macrophages and no active inflammation. All implanted eyes were negative for bacterial or fungal infections. A midgrade granuloma and thick fibrous buildup surrounded the extraocular cable. Scleral closure was maintained in six of seven eyes. There were no staphylomas or choroidal incarceration. A wide-field retinal prosthesis was stable and well tolerated during long-term suprachoroidal implantation in a cat model. The surgical approach was reproducible and overall safe.

  7. Only marginal alignment of disc galaxies

    Science.gov (United States)

    Andrae, René; Jahnke, Knud

    2011-12-01

    Testing theories of angular-momentum acquisition of rotationally supported disc galaxies is the key to understanding the formation of this type of galaxies. The tidal-torque theory aims to explain this acquisition process in a cosmological framework and predicts positive autocorrelations of angular-momentum orientation and spiral-arm handedness, i.e. alignment of disc galaxies, on short distance scales of 1 Mpc h-1. This disc alignment can also cause systematic effects in weak-lensing measurements. Previous observations claimed discovering these correlations but are overly optimistic in the reported level of statistical significance of the detections. Errors in redshift, ellipticity and morphological classifications were not taken into account, although they have a significant impact. We explain how to rigorously propagate all the important errors through the estimation process. Analysing disc galaxies in the Sloan Digital Sky Survey (SDSS) data base, we find that positive autocorrelations of spiral-arm handedness and angular-momentum orientations on distance scales of 1 Mpc h-1 are plausible but not statistically significant. Current data appear not good enough to constrain parameters of theory. This result agrees with a simple hypothesis test in the Local Group, where we also find no evidence for disc alignment. Moreover, we demonstrate that ellipticity estimates based on second moments are strongly biased by galactic bulges even for Scd galaxies, thereby corrupting correlation estimates and overestimating the impact of disc alignment on weak-lensing studies. Finally, we discuss the potential of future sky surveys. We argue that photometric redshifts have too large errors, i.e. PanSTARRS and LSST cannot be used. Conversely, the EUCLID project will not cover the relevant redshift regime. We also discuss the potentials and problems of front-edge classifications of galaxy discs in order to improve the autocorrelation estimates of angular-momentum orientation.

  8. Simulations of Micropumps Based on Tilted Flexible Fibers

    Science.gov (United States)

    Hancock, Matthew; Elabbasi, Nagi; Demirel, Melik

    2015-11-01

    Pumping liquids at low Reynolds numbers is challenging because of the principle of reversibility. We report here a class of microfluidic pump designs based on tilted flexible structures that combines the concepts of cilia (flexible elastic elements) and rectifiers (e.g., Tesla valves, check valves). We demonstrate proof-of-concept with 2D and 3D fluid-structure interaction (FSI) simulations in COMSOL Multiphysics®of micropumps consisting of a source for oscillatory fluidic motion, e.g. a piston, and a channel lined with tilted flexible rods or sheets to provide rectification. When flow is against the rod tilt direction, the rods bend backward, narrowing the channel and increasing flow resistance; when flow is in the direction of rod tilt, the rods bend forward, widening the channel and decreasing flow resistance. The 2D and 3D simulations involve moving meshes whose quality is maintained by prescribing the mesh displacement on guide surfaces positioned on either side of each flexible structure. The prescribed displacement depends on structure bending and maintains mesh quality even for large deformations. Simulations demonstrate effective pumping even at Reynolds numbers as low as 0.001. Because rod rigidity may be specified independently of Reynolds number, in principle, rod rigidity may be reduced to enable pumping at arbitrarily low Reynolds numbers.

  9. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  10. Evaluation of bone and disc configuration in TMJ internal derangement

    International Nuclear Information System (INIS)

    Park, Cheol Woo; Hwang, Eui Hwan; Lee, Sang Rae

    2001-01-01

    To investigate bone and disc configuration on MR images in internal derangement related to age. MR images of 150 TMJs in 107 patients were analyzed to determine the morphologic changes. Two groups were distinguished to be correlated with age. Group 1 consisted of TMJs that were diagnosed as having anterior disc displacement with reduction (ADDwR), and Group 2 consisted of TMJs that were diagnosed as having anterior disc displacement without reduction (ADDwR). We assessed the configuration of the articular disc, degree of anterior disc displacement, and osseous changes of TMJs. The third decade (83 of 150 joints) was most frequent in this study. In the ADDwR group biconcave disc was most frequent at all ages except fifth decade, but in the ADDwoR group deformed discs was most frequent at third and forth decades. In the ADDwR group slightly displaced discs was most frequent at all ages, but in the ADDwoR group severely displaced discs was most frequent at second decade, and the degree of disc displacement was increased with aging over 30 years of age. TM joints showed osseous changes in 17% of the ADDwR group, and in 30% of the ADDwoR group. MR findings of osseous changes of the TMJ were not found to be significantly correlated with age. The prevalence of deformation of disc, displacement of disc, and osseous changes of TMJ was higher in the ADDwoR group than in the ADDwR group. MR findings of disc configuration and degree of disc displacement were found to be correlated with age

  11. A computational study of intervertebral disc degeneration in relation to changes in regional tissue composition and disc nutrition

    OpenAIRE

    Ruiz Wills, Carlos

    2015-01-01

    Up to 85% of the world population suffers from low back pain, a clinical condition often related to the intervertebral disc (IVD) degeneration (DD). Altered disc cell nutrition affects cell viability and can generate catabolic cascades that degrade the extracellular matrix (ECM). Also, a major degenerative biochemical change in the disc is the proteoglycan (PG) loss, which affects the osmotic pressure and hydration that is critical for cell nutrition. However, the relationship between biochem...

  12. Tilted wheel satellite attitude control with air-bearing table experimental results

    Science.gov (United States)

    Inumoh, Lawrence O.; Forshaw, Jason L.; Horri, Nadjim M.

    2015-12-01

    Gyroscopic actuators for satellite control have attracted significant research interest over the years, but their viability for the control of small satellites has only recently started to become clear. Research on variable speed gyroscopic actuators has long been focused on single gimbal actuators; double gimbal actuators typically operate at constant wheel spin rate and allow tilt angle ranges far larger than the ranges needed to operate most satellite missions. This research examines a tilted wheel, a newly proposed type of inertial actuator that can generate torques in all three principal axes of a rigid satellite using a spinning wheel and a double tilt mechanism. The tilt mechanism tilts the angular momentum vector about two axes providing two degree of freedom control, while variation of the wheel speed provides the third. The equations of motion of the system lead to a singularity-free system during nominal operation avoiding the need for complex steering logic. This paper describes the hardware design of the tilted wheel and the experimental setup behind both standalone and spherical air-bearing tables used to test it. Experimental results from the air bearing table are provided with the results depicting the high performance capabilities of the proposed actuator in torque generation.

  13. Schrödinger evolution of self-gravitating discs

    Science.gov (United States)

    Batygin, Konstantin

    2018-04-01

    An understanding of the long-term evolution of self-gravitating discs ranks among the classic outstanding problems of astrophysics. In this work, we show that the secular inclination dynamics of a geometrically thin quasi-Keplerian disc, with a surface density profile that scales as the inverse square-root of the orbital radius, are described by the time-dependent Schrödinger equation. Within the context of this formalism, nodal bending waves correspond to the eigenmodes of a quasi-particle's wavefunction, confined in an infinite square well with boundaries given by the radial extent of the disc. We further show that external secular perturbations upon self-gravitating discs exhibit a mathematical similarity to quantum scattering theory. Employing this framework, we derive an analytic criterion for the gravitational rigidity of a nearly-Keplerian disc under external perturbations. Applications of the theory to circumstellar discs and Galactic nuclei are discussed.

  14. Evidence for accreted component in the Galactic discs

    Science.gov (United States)

    Xing, Q. F.; Zhao, G.

    2018-06-01

    We analyse the distribution of [Mg/Fe] abundance in the Galactic discs with F- and G-type dwarf stars selected from the Large Sky Area Multi-Object Fibre Spectroscopic Telescope (LAMOST) archive. The sample stars are assigned into different stellar populations by using kinematic criteria. Our analysis reveals the chemical inhomogeneities in the Galactic thick disc. A few of metal-poor stars in the thick disc exhibit relatively low [Mg/Fe] abundance in respect to the standard thick-disc sample. The orbital eccentricities and maximum Galactocentric radii of low-α metal-poor stars are apparently greater than that of high-α thick-disc stars. The orbital parameters and chemical components of low-α stars in the thick disc suggest that they may have been formed in regions with low star formation rate that were located at large distances from the Galactic centre, such as infalling dwarf spheroidal galaxies.

  15. Quantum well electronic states in a tilted magnetic field.

    Science.gov (United States)

    Trallero-Giner, C; Padilha, J X; Lopez-Richard, V; Marques, G E; Castelano, L K

    2017-08-16

    We report the energy spectrum and the eigenstates of conduction and uncoupled valence bands of a quantum well under the influence of a tilted magnetic field. In the framework of the envelope approximation, we implement two analytical approaches to obtain the nontrivial solutions of the tilted magnetic field: (a) the Bubnov-Galerkin spectral method and b) the perturbation theory. We discuss the validity of each method for a broad range of magnetic field intensity and orientation as well as quantum well thickness. By estimating the accuracy of the perturbation method, we provide explicit analytical solutions for quantum wells in a tilted magnetic field configuration that can be employed to study several quantitative phenomena.

  16. Gas Modelling in the Disc of HD 163296

    Science.gov (United States)

    Tilling, I.; Woitke, P.; Meeus, G.; Mora, A.; Montesinos, B.; Riviere-Marichalar, P.; Eiroa, C.; Thi, W. -F.; Isella, A.; Roberge, A.; hide

    2011-01-01

    We present detailed model fits to observations of the disc around the Herbig Ae star HD 163296. This well-studied object has an age of approx. 4Myr, with evidence of a circumstellar disc extending out to approx. 540AU. We use the radiation thermo-chemical disc code ProDiMo to model the gas and dust in the circumstellar disc of HD 163296, and attempt to determine the disc properties by fitting to observational line and continuum data. These include new Herschel/PACS observations obtained as part of the open-time key program GASPS (Gas in Protoplanetary Systems), consisting of a detection of the [Oi] 63 m line and upper limits for several other far infrared lines. We complement this with continuum data and ground-based observations of the CO-12 3-2, 2-1 and CO-13 J=1-0 line transitions, as well as the H2 S(1) transition. We explore the effects of stellar ultraviolet variability and dust settling on the line emission, and on the derived disc properties. Our fitting efforts lead to derived gas/dust ratios in the range 9-100, depending on the assumptions made. We note that the line fluxes are sensitive in general to the degree of dust settling in the disc, with an increase in line flux for settled models. This is most pronounced in lines which are formed in the warm gas in the inner disc, but the low excitation molecular lines are also affected. This has serious implications for attempts to derive the disc gas mass from line observations. We derive fractional PAH abundances between 0.007 and 0.04 relative to ISM levels. Using a stellar and UV excess input spectrum based on a detailed analysis of observations, we find that the all observations are consistent with the previously assumed disc geometry

  17. DZ Chamaeleontis: a bona fide photoevaporating disc

    Science.gov (United States)

    Canovas, H.; Montesinos, B.; Schreiber, M. R.; Cieza, L. A.; Eiroa, C.; Meeus, G.; de Boer, J.; Ménard, F.; Wahhaj, Z.; Riviere-Marichalar, P.; Olofsson, J.; Garufi, A.; Rebollido, I.; van Holstein, R. G.; Caceres, C.; Hardy, A.; Villaver, E.

    2018-02-01

    Context. DZ Cha is a weak-lined T Tauri star (WTTS) surrounded by a bright protoplanetary disc with evidence of inner disc clearing. Its narrow Hα line and infrared spectral energy distribution suggest that DZ Cha may be a photoevaporating disc. Aims: We aim to analyse the DZ Cha star + disc system to identify the mechanism driving the evolution of this object. Methods: We have analysed three epochs of high resolution optical spectroscopy, photometry from the UV up to the sub-mm regime, infrared spectroscopy, and J-band imaging polarimetry observations of DZ Cha. Results: Combining our analysis with previous studies we find no signatures of accretion in the Hα line profile in nine epochs covering a time baseline of 20 yr. The optical spectra are dominated by chromospheric emission lines, but they also show emission from the forbidden lines [SII] 4068 and [OI] 6300Å that indicate a disc outflow. The polarized images reveal a dust depleted cavity of 7 au in radius and two spiral-like features, and we derive a disc dust mass limit of Mdust 80 MJup) companions are detected down to 0.̋07 ( 8 au, projected). Conclusions: The negligible accretion rate, small cavity, and forbidden line emission strongly suggests that DZ Cha is currently at the initial stages of disc clearing by photoevaporation. At this point the inner disc has drained and the inner wall of the truncated outer disc is directly exposed to the stellar radiation. We argue that other mechanisms like planet formation or binarity cannot explain the observed properties of DZ Cha. The scarcity of objects like this one is in line with the dispersal timescale (≲105 yr) predicted by this theory. DZ Cha is therefore an ideal target to study the initial stages of photoevaporation. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere under ESO programme 097.C-0536. Based on data obtained from the ESO Science Archive Facility under request number 250112.

  18. Custom-tailored tissue engineered polycaprolactone scaffolds for total disc replacement

    International Nuclear Information System (INIS)

    Van Uden, S; Silva-Correia, J; Correlo, V M; Oliveira, J M; Reis, R L

    2015-01-01

    Degeneration of the intervertebral disc (IVD) represents a significant musculoskeletal disease burden. Tissue engineering has proposed several strategies comprising the use of biodegradable materials to prepare scaffolds that can present mechanical properties similar to those of native IVD tissues. However, this might be insufficient, since the patient’s intervertebral space geometry must be replicated to allow for appropriate implant fixation and integration. Herein, we propose the use of reverse engineering and rapid prototyping techniques with the goal of preparing custom-tailored annulus fibrosus scaffolds; these techniques have previously been applied to rabbit models. The IVD reverse-engineered architecture was obtained by means of microcomputed tomography acquisition and three-dimensional modelling, resulting in a computer-aided design (CAD) that replicates the original rabbit IVD. Later, a fused deposition-modelling three-dimensional printer was used to produce the scaffolds with different geometries provided by the CAD, using polycaprolactone (PCL) with 100% infill density. The microstructure of the PCL scaffolds was investigated by scanning electron microscopy (SEM), which allowed us to observe an adequate fusion adhesion between the layers. The SEM images revealed that, up to the point of moderate resolution, the porosities manually designed in the CAD model were successfully replicated. The PCL scaffolds’ three-dimensional architecture was also assessed by means of microcomputed tomography analysis. Compressive stiffness was determined using a mechanical testing system. Results showed higher values than those of human IVDs (5.9–6.7 kN mm −1 versus 1.2 kN mm −1 , respectively). In vitro studies were performed to investigate the possible cytotoxicity of the polycaprolactone scaffolds’ leachables. The results showed that the custom-tailored PCL scaffolds do not have any deleterious cytotoxic effect over annulus fibrosus cells or the mouse lung

  19. Magnetic resonance imaging of intervertebral disc degeneration

    International Nuclear Information System (INIS)

    Maeda, Hiroshi; Noguchi, Masao; Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi.

    1993-01-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.)

  20. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  1. Proto-CIRCUS tilted-coil tokamak–torsatron hybrid: Design and construction

    Energy Technology Data Exchange (ETDEWEB)

    Clark, A.W.; Doumet, M.; Hammond, K.C. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States); Kornbluth, Y. [Yeshiva University, New York, NY 10033 (United States); Spong, D.A. [Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States); Sweeney, R. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States); Volpe, F.A., E-mail: fvolpe@columbia.edu [Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027 (United States)

    2014-11-15

    Highlights: • A tokamak-like device with tilted toroidal field (TF) coils needs less plasma current than a conventional tokamak. • Rotational transform is partly generated by external coils. Device can be considered a tokamak–torsatron hybrid. • We designed and constructed the first device of this type. • Tilted TF coils are interlinked to each other, which helps to reduce aspect ratio of plasma. • This is a six-coil generalization of CNT stellarator, also at Columbia University, which features two interlinked coils. - Abstract: We present the field-line modeling, design, and construction of a prototype circular-coil tokamak–torsatron hybrid called Proto-CIRCUS. The device has a major radius R = 16 cm and minor radius a < 5 cm. The six “toroidal field” coils are planar as in a tokamak, but they are tilted. This, combined with induced or driven plasma current, is expected to generate rotational transform, as seen in field-line tracing and equilibrium calculations. The device is expected to operate at lower plasma current than a tokamak of comparable size and magnetic field, which might have interesting implications for disruptions and steady-state operation. Additionally, the toroidal magnetic ripple is less pronounced than in an equivalent tokamak in which the coils are not tilted. The tilted coils are interlocked, resulting in a relatively low aspect ratio, and can be moved, both radially and in tilt angle, between discharges. This capability will be exploited for detailed comparisons between calculations and field-line mapping measurements. Such comparisons will reveal whether this relatively simple concept can generate the expected rotational transform.

  2. The comparative study of lumbar disc disruption with MRI and CT discography

    International Nuclear Information System (INIS)

    Chen Xingcan; Liu Naifang; Li Xiaohong; Xu Wengen; Zou Qing; Yang Yonghong

    2005-01-01

    Objective: To compare MRI with CT discography (CTD) for diagnostic assessment of lumbar disc disruption. Methods: Paired comparative examination in 16 patients with chronic lower back pain without radicular pain and no disc herniation was conducted using CT or MRI. The standard of CTD classification and positive disc was formulated and the correlation between the induced lower back pain and dosage used in CTD was observed. Results: For a total of 21 discs in the 16 patients, CTD showed the disc as type 2 in 12 discs and type 5 in 1 disc with 13 positive discs, while MRI only showed the high-intensity zone of posterior annulus in 6 discs as the indirect sign of disc disruption and disc degeneration in 7 discs. Conclusion: CTD was the only method for showing the direct sign of disc disruption. The induced lower back pain was related with the type of disc disruption. MRI can show some of the indirect signs of disc disruption and CTD can show the direct sign of disc disruption. (authors)

  3. Tilt sensor and servo control system for gravitational wave detection

    CERN Document Server

    Cheng, Y; Ju, L; Blair, D G

    2002-01-01

    This paper describes the design of a novel double-flexure two-axis tilt sensor with a tilt readout based on an optical walk-off sensor. The performance of the device has been investigated theoretically and experimentally. The walk-off sensor has demonstrated a sensitivity of 10 sup - sup 1 sup 1 rad Hz sup - sup 1 sup / sup 2 at 1 Hz. The tilt sensor has measured seismic noise approx 10 sup - sup 9 -10 sup - sup 1 sup 0 rad Hz sup - sup 1 sup / sup 2 for frequency in the 2-10 Hz range.

  4. Exoplanet recycling in massive white-dwarf debris discs

    Science.gov (United States)

    van Lieshout, R.; Kral, Q.; Charnoz, S.; Wyatt, M. C.; Shannon, A.

    2018-05-01

    Several tens of white dwarfs are known to host circumstellar discs of dusty debris, thought to arise from the tidal disruption of rocky bodies originating in the star's remnant planetary system. This paper investigates the evolution of such discs if they are very massive, as may be the case if their progenitor was a terrestrial planet, moon, or dwarf planet. Assuming the discs are physically thin and flat, like Saturn's rings, their evolution is governed by Poynting-Robertson drag or viscous spreading, where the disc's effective viscosity is due to self-gravity wakes. For discs with masses ≳ 1026 g, located in the outer parts of the tidal disruption zone, viscous spreading dominates the evolution, and mass is transported both in- and outwards. When outwards-spreading material flows beyond the Roche limit, it coagulates into new (minor) planets in a process analogous to the ongoing formation of moonlets at the outer edge of Saturn's rings. The newly formed bodies migrate outwards by exchanging angular momentum with the disc and coalesce into larger objects through mutual collisions. Eventually, the disc's Roche-limit overflow recycles tens of percent of the original disc mass; most ends up in a single large body near 2:1 mean-motion resonance with the disc's outer edge. Hence, the recycling of a tidally disrupted super-Earth, for example, could yield an Earth-mass planet on a ˜10-h orbit, located in the habitable zone for 2-to-10-Gyr-old white dwarfs. The recycling process also creates a population of smaller bodies just outside the Roche limit, which may explain the minor planets recently postulated to orbit WD 1145+017.

  5. Design and Development of Tilting Rotary Furnace

    Science.gov (United States)

    Sai Varun, V.; Tejesh, P.; Prashanth, B. N.

    2018-02-01

    Casting is the best and effective technique used for manufacturing products. The important accessory for casting is furnace. Furnace is used to melt the metal. A perfect furnace is one that reduces the wastage of material, reduces the cost of manufacturing and there by reduces the cost of production. Of all the present day furnaces there may be wastage of material, and the chances of increasing the time of manufacturing as the is continuous need of tilting of the furnace for every mould and then changing the moulds. Considering these aspects, a simple and least expensive tilting rotary furnace is designed and developed. The Tilting and Rotary Furnace consists of mainly melting chamber and the base. The metal enters the melting chamber through the input door that is provided on the top of the melting chamber. Inside the melting chamber there is a graphite furnace. The metal is melted in the graphite crucible. An insulation of ceramic fibre cloth is provided inside the furnace. The metal is melted using Propane gas. The propane gas is easily available and economic. The gas is burned using a pilot burner. The pilot burner is more efficient that other burners. The pilot burner is lit with a push button igniter. The pilot burner is located at the bottom of the combustion chamber. This enables the uniform heating of the metal inside the crucible. The temperature inside the melting chamber is noted using a temperature sensor. The gas input is cut-off if the temperature is exceeding a specific temperature. After the melting of the metal is done the furnace is tilted and after the mould is filled it is rotated. The external gears are used to controlling the tilting. The results of studies carried out for the design & development of low cost, simple furnace that can be mounted anywhere on the shop floor and this can be very much useful for the education purposes and small scale manufacturing. The furnace can be rotated in 360 degrees and can help in reducing the time taken

  6. SIMULTANEOUS DISC HERNIATION IN PATIENTS WITH MULTIPLE SCLEROSIS

    Directory of Open Access Journals (Sweden)

    Kalina V. Drenska

    2013-04-01

    Full Text Available Background: Multiple sclerosis (MS is a chronic autoimmune, inflammatory demyelinating disease of the central nervous system. Commonly, MS patients present with accompanying degenerative vertebral disc diseases. Simultaneous disc herniations situated in the cervical or lumbosacral spine can mimic the clinical symptoms of MS and worsen patients’ quality of life.Objective: to investigate the incidence rate and clinical impact of accompanying disc herniations in patients with MS.Material and methods: Our study covered 330 patients (220 females and 110 males, mean age 40.5±12.4 years with clinically definite MS, according to McDonald’s criteria. Comprehensive neurological examinations, EDSS (Expanded Disability Status Scale assessments, and MRI neuroimaging were carried out. Statistical data processing was performed by using the method of variation analysis.Results: Relapsing-remitting MS (RRMS was diagnosed in 280 patients while 50 patients presented with secondary progressive MS (SPMS. Disc herniation was found in 64 (19.4% of our patients. Cervical disc pathology was detected in 38 patients (11.5% of the cases and lumbosacral - in 26 (7.9% of the cases. EDSS scores ranged from 2.5 to 5.5. EDSS evaluation showed statistically significantly worse scores in MS patients with disc herniation comorbidity (p<0, 05.Conclusion: Our own data confirm the assumption that MS patients often present with accompanying degenerative disc pathology. We suggest that comorbidity of disc herniation and MS exert an additional unfavorable effect on patient’s disability and individual quality of life.

  7. CT in diagnosis of recurrent vertebral disc hernias after preceding lumbar disc prolapse surgery

    International Nuclear Information System (INIS)

    Burval, S.; Nekula, J.; Vaverka, M.; Veliskova, J.

    1992-01-01

    20 patients with recurrent symptoms following operations for disc prolapse and resistant to treatment were studied by CT, using plain and enhanced images. The results have been analysed. In 10 patients a recurrence of disc prolapse was diagnosed, and this was confirmed surgically in 8 cases. In 2 patients there was epidural scarring. The findings indicate that differential diagnosis between scarring and recurring prolapse can by accurately made by this technique. (orig.) [de

  8. Height and Tilt Geometric Texture

    DEFF Research Database (Denmark)

    Andersen, Vedrana; Desbrun, Mathieu; Bærentzen, Jakob Andreas

    2009-01-01

    compromise between functionality and simplicity: it can efficiently handle and process geometric texture too complex to be represented as a height field, without having recourse to full blown mesh editing algorithms. The height-and-tilt representation proposed here is fully intrinsic to the mesh, making...

  9. LUMBOSACRAL TRANSITIONAL ANATOMY TYPES AND DISC DEGENERATIVE CHANGES

    Directory of Open Access Journals (Sweden)

    Chabukovska Radulovska Jasminka

    2014-07-01

    Full Text Available Background and purpose: The relationship between presence of lumbo sacral transitional vertebra (LSTV and disc degenerative changes is unclear. The aim of the study was to examine the relation between different types of LSTV and disc degenerative changes at the transitional and the adjacent cephalad segment. Material and methods: Sixty-three patients (mean age 51.48 ± 13.51 out of 200 adults with low back pain who performed MRI examination of the lumbo sacral spine, classified as positive for LSTV, were included in the study. Annular tears, disc degeneration according to Phirmann classification and disc herniations were evaluated and graded at transitional and adjacent cephalad level. Results: The severity of disc degeneration at the transitional level and the adjacent level correlated with the types of LSTV. Severe disc degenerative changes were most frequent in articulated connection LSTV types and incombined LSTV type at the transitional level and in osseus connection LSTV types at the adjacent cephalad level. These changes were more frequent in unilateral articulated connection LSTV subtype (64% vs 54%; and in unilateral osseus connection LSTV subtype (25% vs no patients at transitional level, and in bilateral osseus connection LSTV subtype (100% vs 50% at the level above. High prevalence of disc herniations was observed in articulated connection LSTV types as well as in unilateral osseus connection LSTV subtype at transitional and the adjacent cephalad level. At the transitional level higher prevalence of disc herniations was characteristic for unilateral articulated connection LSTV sub type (46%vs 41% and for unilateral osseus connection LSTV subtype (50% vs no patients. At the adjacent level higher prevalence of disc herniations was observed in bilateral articulated connection LSTV subtype (38% vs 27% and in bilateral osseus connection LSTV subtype (50% vs 25%. Conclusions: The compact osseus connection (osseus bridging vs articular

  10. Lumbosacral transitional anatomy types and disc degenerative changes

    Directory of Open Access Journals (Sweden)

    Chabukovska-Radulovska Jasminka

    2014-07-01

    Full Text Available Background and purpose: The relationship between presence of lumbosacral transitional vertebra (LSTV and disc degenerative changes is unclear. The aim of the study was to examine the relation between different types of LSTV and disc degenerative changes at the transitional and the adjacent cephalad segment. Material and methods: Sixty-three patients (mean age 51.48 ± 13.51 out of200 adults with low back pain who performed MRI examination of the lumbosacral spine, classified as positive for LSTV, were included in the study. Annular tears, disc degeneration according to Phirmann classification and disc herniations were evaluated and graded at transitional and adjacent cephalad level. Results: The severity of disc degeneration at the transitional level and the adjacent level correlated with the types of LSTV. Severe disc degenerative changes were most frequent in articulated connection LSTV types and in combined LSTV type at the transitional level and in osseus connection LSTV types at the adjacent cephalad level. These changes were more frequent in unilateral articulated connection LSTV subtype (64% vs 54%; and in unilateral osseus connection LSTV subtype (25% vs no patients at transitional level, and in bilateral osseus connection LSTV subtype (100% vs 50% at the level above. High prevalence of disc herniations was observed in articulated connection LSTV types as well as in unilateral osseus connection LSTV subtype at transitional and the adjacent cephalad level. At the transitional level higher prevalence of disc herniations was characteristic for unilateral articulated connection LSTV subtype (46%vs 41% and for unilateral osseus connection LSTV subtype (50% vs no patients. At the adjacent level higher prevalence of disc herniations was observed in bilateral articulated connection LSTV subtype (38% vs 27% and in bilateral osseus connection LSTV subtype (50% vs 25%. Conclusions: The compact osseus connection (osseus bridging vs articular

  11. Development and Evaluation of Polyvinyl Alcohol-Hydrogels as an Artificial Atrticular Cartilage for Orthopedic Implants

    Directory of Open Access Journals (Sweden)

    Masanori Kobayashi

    2010-04-01

    Full Text Available Due to its excellent biocompatibility and mechanical properties, various different applications of polyvinyl alcohol-hydrogels (PVA-H has been attempted in many fields. In the field of orthopedic surgery, we have been engaged for long time in research on the clinical applications of PVA-H as a artificial cartilage, and have performed many basic experiments on the mechanical properties, synthesis of PVA-H, and developed orthopedic implants using PVA-H. From these studies, many applications of artificial articular cartilage, intervertbral disc and artificial meniscus etc. have been developed. This review will present the overview of the applications and recent advances of PVA-H cartilages, and discuss clinical potential of PVA-H for orthopedics implant.

  12. Development and Evaluation of Polyvinyl Alcohol-Hydrogels as an Artificial Atrticular Cartilage for Orthopedic Implants

    Science.gov (United States)

    Kobayashi, Masanori; Hyu, Hyon Suong

    2010-01-01

    Due to its excellent biocompatibility and mechanical properties, various different applications of polyvinyl alcohol-hydrogels (PVA-H) has been attempted in many fields. In the field of orthopedic surgery, we have been engaged for long time in research on the clinical applications of PVA-H as a artificial cartilage, and have performed many basic experiments on the mechanical properties, synthesis of PVA-H, and developed orthopedic implants using PVA-H. From these studies, many applications of artificial articular cartilage, intervertbral disc and artificial meniscus etc. have been developed. This review will present the overview of the applications and recent advances of PVA-H cartilages, and discuss clinical potential of PVA-H for orthopedics implant.

  13. Rules and mechanisms governing octahedral tilts in perovskites under pressure

    Science.gov (United States)

    Xiang, H. J.; Guennou, Mael; Íñiguez, Jorge; Kreisel, Jens; Bellaiche, L.

    2017-08-01

    The rotation of octahedra (octahedral tilting) is common in A B O3 perovskites and relevant to many physical phenomena, ranging from electronic and magnetic properties, metal-insulator transitions to improper ferroelectricity. Hydrostatic pressure is an efficient way to tune and control octahedral tiltings. However, the pressure behavior of such tiltings can dramatically differ from one material to another, with the origins of such differences remaining controversial. In this paper, we discover several new mechanisms and formulate a set of simple rules that allow us to understand how pressure affects oxygen octahedral tiltings via the use and analysis of first-principles results for a variety of compounds. Besides the known A -O interactions, we reveal that the interactions between specific B ions and oxygen ions contribute to the tilting instability. We explain the previously reported trend that the derivative of the oxygen octahedral tilting with respect to pressure (dR /dP ) usually decreases with both the tolerance factor and the ionization state of the A ion by illustrating the key role of A -O interactions and their change under pressure. Furthermore, three new mechanisms/rules are discovered, namely that (i) the octahedral rotations in A B O3 perovskites with empty low-lying d states on the B site are greatly enhanced by pressure, in order to lower the electronic kinetic energy; (ii) dR /dP is enhanced when the system possesses weak tilt instabilities, and (iii) for the most common phase exhibited by perovskites—the orthorhombic Pbnm state—the in-phase and antiphase octahedral rotations are not automatically both suppressed or both enhanced by the application of pressure because of a trilinear coupling between these two rotation types and an antipolar mode involving the A ions. We further predict that the polarization associated with the so-called hybrid improper ferroelectricity could be manipulated by hydrostatic pressure by indirectly controlling the

  14. Comparison of Modelled and Measured Tilted Solar Irradiance for Photovoltaic Applications

    Directory of Open Access Journals (Sweden)

    Riyad Mubarak

    2017-10-01

    Full Text Available This work assesses the performance of five transposition models that estimate the global and diffuse solar irradiance on tilted planes based on the global horizontal irradiance. The modelled tilted irradiance values are compared to measured one-minute values from pyranometers and silicon sensors tilted at different angles at Hannover (Germany and NREL (Golden, CO, USA. It can be recognized that the deviations of the model of Liu and Jordan, Klucher and Perez from the measurements increases as the tilt angle increases and as the sensors are oriented away from the south direction, where they receive lower direct radiation than south-oriented surfaces. Accordingly, the vertical E, W and N planes show the highest deviation. Best results are found by the models from Hay and Davies and Reindl, when horizontal pyranometer measurements and a constant albedo value of 0.2 are used. The relative root mean squared difference (rRMSD of the anisotropic models does not exceed 11% for south orientation and low inclination angles (β = 10–60°, but reaches up to 28.9% at vertical planes. For sunny locations such as Golden, the Perez model provides the best estimates of global tilted irradiance for south-facing surfaces. The relative mean absolute difference (rMAD of the Perez model at NREL ranges from 4.2% for 40° tilt to 8.7% for 90° tilt angle, when horizontal pyranometer measurements and a measured albedo value are used; the use of measured albedo values instead of a constant value of 0.2 leads to a reduction of the deviation to 3.9% and 6.0%, respectively. The use of higher albedo values leads to a significant increase of rMAD. We also investigated the uncertainty resulting from using horizontal pyranometer measurements, in combination with constant albedo values, to estimate the incident irradiance on tilted photovoltaic (PV modules. We found that these uncertainties are small or negligible.

  15. The evolution of stellar exponential discs

    NARCIS (Netherlands)

    Ferguson, AMN; Clarke, CJ

    2001-01-01

    Models of disc galaxies which invoke viscosity-driven radial flows have long been known to provide a natural explanation for the origin of stellar exponential discs, under the assumption that the star formation and viscous time-scales are comparable. We present models which invoke simultaneous star

  16. Evaluation of various procedures transposing global tilted irradiance to horizontal surface irradiance

    Science.gov (United States)

    Housmans, Caroline; Bertrand, Cédric

    2017-02-01

    Many transposition models have been proposed in the literature to convert solar irradiance on the horizontal plane to that on a tilted plane. The inverse process, i.e. the conversion from tilted to horizontal is investigated here based upon seven months of in-plane global solar irradiance measurements recorded on the roof of the Royal Meteorological Institute of Belgium's radiation tower in Uccle (Longitude 4.35° E, Latitude 50.79° N). Up to three pyranometers mounted on inclined planes of different tilts and orientations were involved in the inverse transposition process. Our results indicate that (1) the tilt to horizontal irradiance conversion is improved when measurements from more than one tilted pyranometer are considered (i.e. by using a multi-pyranometer approach) and (2) the improvement from using an isotropic model to anisotropic models in the inverse transposition problem is not significant.

  17. Grain size segregation in debris discs

    Science.gov (United States)

    Thebault, P.; Kral, Q.; Augereau, J.-C.

    2014-01-01

    Context. In most debris discs, dust grain dynamics is strongly affected by stellar radiation pressure. Because this mechanism is size-dependent, we expect dust grains to be spatially segregated according to their sizes. However, because of the complex interplay between radiation pressure, grain processing by collisions, and dynamical perturbations, this spatial segregation of the particle size distribution (PSD) has proven difficult to investigate and quantify with numerical models. Aims: We propose to thoroughly investigate this problem by using a new-generation code that can handle some of the complex coupling between dynamical and collisional effects. We intend to explore how PSDs behave in both unperturbed discs at rest and in discs pertubed by planetary objects. Methods: We used the DyCoSS code to investigate the coupled effect of collisions, radiation pressure, and dynamical perturbations in systems that have reached a steady-state. We considered two setups: a narrow ring perturbed by an exterior planet, and an extended disc into which a planet is embedded. For both setups we considered an additional unperturbed case without a planet. We also investigated the effect of possible spatial size segregation on disc images at different wavelengths. Results: We find that PSDs are always spatially segregated. The only case for which the PSD follows a standard dn ∝ s-3.5ds law is for an unperturbed narrow ring, but only within the parent-body ring itself. For all other configurations, the size distributions can strongly depart from such power laws and have steep spatial gradients. As an example, the geometrical cross-section of the disc is very rarely dominated by the smallest grains on bound orbits, as it is expected to be in standard PSDs in sq with q ≤ -3. Although the exact profiles and spatial variations of PSDs are a complex function of the set-up that is considered, we are still able to derive some reliable results that will be useful for image or SED

  18. Modelling and simulation of a compliant tilting pad air bearing

    NARCIS (Netherlands)

    Duijnhouwer, F.; Nijmeijer, H.

    The compliant tilting pad air bearing concept, a tilting pad bearing with the pivot of the pads placed on radial springs, is a promising aerodynamic bearing solution. Nevertheless, its non-linear dynamics make a time domain dynamic simulation model an essential tool for the design of rotor systems

  19. Time Localisation of Surface Defects on Optical Discs

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Wickerhauser, M.V.

    Many have experienced problems with their Compact Disc player when a disc with a scratch or a finger print is tried played. One way to improve the playability of discs with such a defect, is to locate the defect in time and then handle it in a special way. As a consequence this time localisation...

  20. Time Localisation of Surface Defects on Optical Discs

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Wickerhauser, M.V.

    2004-01-01

    Many have experienced problems with their Compact Disc Player when a disc with a scratch or a fingerprint is tried played. One way to improve the playability of discs with such a defect, is to locate the defect in time and then handle it in a special way. As a consequence this time localization...

  1. Intradiscal injection of simvastatin results in radiologic, histologic, and genetic evidence of disc regeneration in a rat model of degenerative disc disease

    Science.gov (United States)

    Than, Khoi D.; Rahman, Shayan U.; Wang, Lin; Khan, Adam; Kyere, Kwaku A.; Than, Tracey T.; Miyata, Yoshinari; Park, Yoon-Shin; La Marca, Frank; Kim, Hyungjin M.; Zhang, Huina; Park, Paul; Lin, Chia-Ying

    2014-01-01

    BACKGROUND CONTEXT A large percentage of back pain can be attributed to degeneration of the intervertebral disc (IVD). Bone morphogenetic protein-2 (BMP-2) is known to play an important role in chondrogenesis of the IVD. Simvastatin is known to up-regulate expression of BMP-2. Thus, we hypothesized that intradiscal injection of simvastatin in a rat model of degenerative disc disease (DDD) would result in retardation of DDD. PURPOSE To develop a novel conservative treatment for DDD and related discogenic back pain. STUDY DESIGN/SETTING Laboratory investigation. METHODS Disc injury was induced in 272 rats via 21-gauge needle puncture. After 6 weeks, injured discs were treated with simvastatin in a saline or hydrogel carrier. Rats were sacrificed at predetermined time points. Outcome measures assessed were radiologic, histologic, and genetic. Radiologically, the MRI index (number of pixels multiplied by corresponding image densities) was determined. Histologically, disc spaces were read by 3 blinded scorers employing a previously described histological grading scale. Genetically, nuclei pulposi were harvested and polymerase chain reaction was run to determine relative levels of aggrecan, collagen type II, and BMP-2 gene expression. This project was supported by Grant No. R01 AR056649 from NIAMS/NIH. There are no other financial conflicts of interest to report. RESULTS Radiologically, discs treated with 5 mg/mL simvastatin in hydrogel or saline demonstrated MRI indices that were normal through 8 weeks post-treatment, although this was more sustained when delivered in hydrogel. Histologically, discs treated with 5 mg/mL simvastatin in hydrogel demonstrated improved grades in comparison to discs treated at higher doses. Genetically, discs treated with 5 mg/mL of simvastatin in hydrogel demonstrated higher gene expression of aggrecan and collagen type II than control. CONCLUSIONS Degenerate discs treated with 5 mg/mL simvastatin in a hydrogel carrier demonstrated

  2. New Brown Dwarf Discs in Upper Scorpius Observed with WISE

    Science.gov (United States)

    Dawson, P.; Scholz, A.; Ray, T. P.; Natta, A.; Marsh, K. A.; Padgett, D.; Ressler, M. E.

    2013-01-01

    We present a census of the disc population for UKIDSS selected brown dwarfs in the 5-10 Myr old Upper Scorpius OB association. For 116 objects originally identified in UKIDSS, the majority of them not studied in previous publications, we obtain photometry from the Wide-Field Infrared Survey Explorer data base. The resulting colour magnitude and colour colour plots clearly show two separate populations of objects, interpreted as brown dwarfs with discs (class II) and without discs (class III). We identify 27 class II brown dwarfs, 14 of them not previously known. This disc fraction (27 out of 116, or 23%) among brown dwarfs was found to be similar to results for K/M stars in Upper Scorpius, suggesting that the lifetimes of discs are independent of the mass of the central object for low-mass stars and brown dwarfs. 5 out of 27 discs (19 per cent) lack excess at 3.4 and 4.6 microns and are potential transition discs (i.e. are in transition from class II to class III). The transition disc fraction is comparable to low-mass stars.We estimate that the time-scale for a typical transition from class II to class III is less than 0.4 Myr for brown dwarfs. These results suggest that the evolution of brown dwarf discs mirrors the behaviour of discs around low-mass stars, with disc lifetimes of the order of 5 10 Myr and a disc clearing time-scale significantly shorter than 1 Myr.

  3. Method to fabricate a tilted logpile photonic crystal

    Science.gov (United States)

    Williams, John D.; Sweatt, William C.

    2010-10-26

    A method to fabricate a tilted logpile photonic crystal requires only two lithographic exposures and does not require mask repositioning between exposures. The mask and photoresist-coated substrate are spaced a fixed and constant distance apart using a spacer and the stack is clamped together. The stack is then tilted at a crystallographic symmetry angle (e.g., 45 degrees) relative to the X-ray beam and rotated about the surface normal until the mask is aligned with the X-ray beam. The stack is then rotated in plane by a small stitching angle and exposed to the X-ray beam to pattern the first half of the structure. The stack is then rotated by 180.degree. about the normal and a second exposure patterns the remaining half of the structure. The method can use commercially available DXRL scanner technology and LIGA processes to fabricate large-area, high-quality tilted logpile photonic crystals.

  4. Do tilt-in-space wheelchairs increase occupational engagement: a critical literature review.

    Science.gov (United States)

    Harrand, Jenny; Bannigan, Katrina

    2016-01-01

    A wheelchair can enhance the quality of life of an individual with limited mobility, poor trunk control and stability, by enabling activity and participation and so occupational engagement. High specification wheelchairs which can tilt-in-space enable the position of users to be altered to suit activity and context. Despite tilt-in-space wheelchairs being expensive little is known about their therapeutic value. A critical literature review of the evidence was undertaken to evaluate whether the use of tilt-in-space increases occupational engagement. A wide ranging search strategy identified 170 articles which were screened using inclusion criteria. The eligible literature (n = 6) was analysed thematically using open coding. The majority of the participants used tilt-in-space but the data was too heterogeneous to combine. Measures of occupational engagement were not used so the therapeutic value could not be assessed. There is a lack of high quality evidence about the therapeutic benefits of tilt-in-space wheelchairs. Given the expense associated with providing these wheelchairs, and the increase in their provision, research is needed to justify provision of high specification wheelchairs to meet the occupational needs of users within the limited resources of health and social care. Implications for Rehabilitation Tilt-in-space wheelchairs. Wheelchairs are an important and essential assistive device for promoting independence and function. Suggests there are benefits for tilt-in-space wheelchairs. Identifies the need for additional large scale research.

  5. Development of a tilting system for electric multiple unit to speed up on conventional lines

    International Nuclear Information System (INIS)

    Seo, Sung Il; Kim, Nam Po; Lee, Soo Gil; Kim, Seok Won

    2008-01-01

    An advanced tilting system for KTT (Korean Tilting Train) was developed and a performance test of the system has been completed. KTT has been constructed to speed up and promise a significant enhancement in service quality on a conventional line. KTT is an electric multiple unit composed of 6 cars running at the design speed of 200 km/h. The tilting system is the core technology of KTT and combined with the conventional bogie system. It has a self-steering mechanism and a swing link. The self-steering mechanism of Z-bar type is free to rotate on the curve and stable to run on a straight line. The swing link mechanism of the bolster enables the carbody to tilt up to 8 .deg.. A tilting control system detects a curve with sensors and commands the electro-mechanical actuators to move the bolster through the computer network system. GPS collaborates with the tilting system to perceive the curve previously and enables gradual tilting so as not to violate passenger comfort. The performance of the tilting system has been verified by a trial test running of KTT on a commercial conventional line. The tilting system is ready for commercial use

  6. MRI findings of traumatic cervical disc herniation

    International Nuclear Information System (INIS)

    Tanaka, Hisato; Kasahara, Takaki; Akiyama, Nanae

    2011-01-01

    In general practice, disc hernia is increasingly being questioned about its relation with traffic injuries. In this study, we examined the image findings of cervical disc herniation for findings indicative of traumatic hernia. In 2008, we examined 35 cases of cervical disc herniation at our hospital by MRI. The patients were divided into two groups; patients with trauma history (19 cases) and those without (16 cases), and their images were compared. Disc herniation in the trauma group showed high intensity at T2, with some of the patients in this group also indicating continuous high intensity of the internal and herniated discs. Traumatic force was found to cause swelling under the laryngeal soft tissue. Cases with further flexion injury showed interspinous ligament hemorrhage. These findings strongly suggest the involvement of injury. But given that some younger patients in the non-trauma group also show high intensity at T2*, attention must be paid not to confuse swelling below the larynx with inflammation of the longus colli muscle. (author)

  7. Physical Limitations to Tissue Engineering of Intervertabral Disc Cells

    OpenAIRE

    Kobayashi, Shigeru; Baba, Hisatoshi; Takeno, Kenichi; Miyazaki, Tsuyoshi; Meir, Adam; Urban, Jill

    2010-01-01

    There is increasing interest in the using biological methods to repair degenerate discs. Biological repair depends on the disc maintaining a population of viable and active cells. Adequate nutrition of the disc influences the outcome of such therapies and, hence, must be considered to be a crucial parameter. Therefore, it is very important to maintain an appropriate physicochemical environment to achieve successful disc repair by biological methods and tissue engineering procedures.

  8. Nonlinear dynamics of the human lumbar intervertebral disc.

    Science.gov (United States)

    Marini, Giacomo; Huber, Gerd; Püschel, Klaus; Ferguson, Stephen J

    2015-02-05

    Systems with a quasi-static response similar to the axial response of the intervertebral disc (i.e. progressive stiffening) often present complex dynamics, characterized by peculiar nonlinearities in the frequency response. However, such characteristics have not been reported for the dynamic response of the disc. The accurate understanding of disc dynamics is essential to investigate the unclear correlation between whole body vibration and low back pain. The present study investigated the dynamic response of the disc, including its potential nonlinear response, over a range of loading conditions. Human lumbar discs were tested by applying a static preload to the top and a sinusoidal displacement at the bottom of the disc. The frequency of the stimuli was set to increase linearly from a low frequency to a high frequency limit and back down. In general, the response showed nonlinear and asymmetric characteristics. For each test, the disc had different response in the frequency-increasing compared to the frequency-decreasing sweep. In particular, the system presented abrupt changes of the oscillation amplitude at specific frequencies, which differed between the two sweeps. This behaviour indicates that the system oscillation has a different equilibrium condition depending on the path followed by the stimuli. Preload and amplitude of the oscillation directly influenced the disc response by changing the nonlinear dynamics and frequency of the jump-phenomenon. These results show that the characterization of the dynamic response of physiological systems should be readdressed to determine potential nonlinearities. Their direct effect on the system function should be further investigated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Prevalence of disc cupping in non-glaucomatous eyes

    Directory of Open Access Journals (Sweden)

    José Pablo Chiappe

    2015-02-01

    Full Text Available This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter 1.5 times (respectively the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81% were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg. There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001; therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7% small, 141 (76.6% medium and 16 (8.7% large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

  10. Efficacy and safety of Mobi-C cervical artificial disc versus anterior discectomy and fusion in patients with symptomatic degenerative disc disease: A meta-analysis.

    Science.gov (United States)

    Lu, Hui; Peng, Lihua

    2017-12-01

    Total disc replacement (TDR) using Mobi-C cervical artificial disc might be promising to treat symptomatic degenerative disc disease. However, the results remained controversial. We conducted a systematic review and meta-analysis to compare the efficacy and safety of Mobi-C cervical artificial disc and anterior cervical discectomy and fusion (ACDF) in patients with symptomatic degenerative disc disease. PubMed, EMbase, Web of science, EBSCO, and Cochrane library databases were systematically searched. Randomized controlled trials (RCTs) assessing the effect of Mobi-C versus ACDF on the treatment of symptomatic degenerative disc disease were included. Two investigators independently searched articles, extracted data, and assessed the quality of included studies. The primary outcomes were neck disability index (NDI) score, patient satisfaction, and subsequent surgical intervention. Meta-analysis was performed using the random-effect model. Four RCTs were included in the meta-analysis. Overall, compared with ACDF surgery for symptomatic degenerative disc disease, TDR using Mobi-C was associated with a significantly increased NDI score (Std. mean difference = 0.32; 95% CI = 0.10-0.53; P = .004), patient satisfaction (odds risk [OR] = 2.75; 95% confidence interval [CI] = 1.43-5.27; P = .002), and reduced subsequent surgical intervention (OR = 0.20; 95% CI = 0.11-0.37; P degenerative disc disease, TDR using Mobi-C cervical artificial disc resulted in a significantly improved NDI score, patient satisfaction, and reduced subsequent surgical intervention. There was no significant difference of neurological deterioration, radiographic success, and overall success between TDR using Mobi-C cervical artificial disc versus ACDF surgery. TDR using Mobi-C cervical artificial disc should be recommended for the treatment of symptomatic degenerative disc disease.

  11. Substorm onset location and dipole tilt angle

    Directory of Open Access Journals (Sweden)

    J. Wanliss

    2006-03-01

    Full Text Available From an initial data set of over 200 substorms we have studied a subset of 30 magnetospheric substorms close to magnetic midnight to investigate, in a statistical fashion, the source region of the auroral arc that brightens at the onset of expansive phase. This arc is usually identified as the ionospheric signature of the expansive phase onset that occurs in the magnetotail. All the substorm onsets were identified via ground-based magnetometer and photometer data from the CANOPUS array. Various Tsyganenko global magnetic field models were used to map magnetic field lines from the location of the onset arc out to its greatest radial distance in the magnetotail. The results appear to favour the current disruption model of substorms since the average onset location has an average of 14.1 Earth radii (RE and is therefore more consistent with theories that place the onset location in the inner magnetotail. For the narrow range of tilts available our modeling indicates the parameter that appears to strongly influence the location of the substorm onset is the dipole tilt angle; as tilt becomes less negative onsets occur further downtail.

  12. Design of a Piezoelectric-Driven Tilt Mirror for a Fast Laser Scanner

    Science.gov (United States)

    Park, Jung-Ho; Lee, Hu-Seung; Lee, Jae-Hoon; Yun, So-Nam; Ham, Young-Bog; Yun, Dong-Won

    2012-09-01

    Recently, laser scanners have been used for laser processing such as cutting, welding, and grooving, especially in the automotive industry. The laser scanners need a high-speed driving to minimize cracks caused by thermal shock of brittle materials. Therefore, a novel laser processing system that is composed of a laser source and a piezoelectric-driven tilt mirror to control the reflection angle of the laser beam, and a stage equipped with the tilt mirror has been investigated. In this study, a piezoelectric-driven tilt mirror is designed and analyzed for scanning performance to achieve a beam spot of 30 µm, a pattern width of 1 mm, an overlap ratio of 70% of the circle area, and a scanning speed of 1 m/s. Then, structural analysis of the tilt mirror with three piezoelectric actuators is performed to determine the maximum reflection angle and resonance frequency. Finally, a prototype tilt mirror is fabricated and its basic characteristics are experimentally investigated and discussed.

  13. Modulated electron bunch with amplitude front tilt in an undulator

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2015-12-01

    In a previous paper we discussed the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick. We demonstrated that the effect of aberration of light supplies the basis for understanding phenomena like the deflection of coherent undulator radiation by a dipole magnet. We illustrated this fact by examining the operation of an XFEL under the steady state assumption, that is a harmonic time dependence. We argued that in this particular case the microbunch front tilt has no objective meaning; in other words, there is no experiment that can discriminate whether an electron beam is endowed with a microbunch front tilt of not. In this paper we extend our considerations to time-dependent phenomena related with a finite electron bunch duration, or SASE mode of operation. We focus our attention on the spatiotemporal distortions of an X-ray pulse. Spatiotemporal coupling arises naturally in coherent undulator radiation behind the kick, because the deflection process involves the introduction of a tilt of the bunch profile. This tilt of the bunch profile leads to radiation pulse front tilt, which is equivalent to angular dispersion of the output radiation. We remark that our exact results can potentially be useful to developers of new generation XFEL codes for cross-checking their results.

  14. Apparent quasar disc sizes in the "bird's nest" paradigm

    Science.gov (United States)

    Abolmasov, P.

    2017-04-01

    Context. Quasar microlensing effects make it possible to measure the accretion disc sizes around distant supermassive black holes that are still well beyond the spatial resolution of contemporary instrumentation. The sizes measured with this technique appear inconsistent with the standard accretion disc model. Not only are the measured accretion disc sizes larger, but their dependence on wavelength is in most cases completely different from the predictions of the standard model. Aims: We suggest that these discrepancies may arise not from non-standard accretion disc structure or systematic errors, as it was proposed before, but rather from scattering and reprocession of the radiation of the disc. In particular, the matter falling from the gaseous torus and presumably feeding the accretion disc may at certain distances become ionized and produce an extended halo that is free from colour gradients. Methods: A simple analytical model is proposed assuming that a geometrically thick translucent inflow acts as a scattering mirror changing the apparent spatial properties of the disc. This inflow may be also identified with the broad line region or its inner parts. Results: Such a model is able to explain the basic properties of the apparent disc sizes, primarily their large values and their shallow dependence on wavelength. The only condition required is to scatter a significant portion of the luminosity of the disc. This can easily be fulfilled if the scattering inflow has a large geometrical thickness and clumpy structure.

  15. Numerical tilting compensation in microscopy based on wavefront sensing using transport of intensity equation method

    Science.gov (United States)

    Hu, Junbao; Meng, Xin; Wei, Qi; Kong, Yan; Jiang, Zhilong; Xue, Liang; Liu, Fei; Liu, Cheng; Wang, Shouyu

    2018-03-01

    Wide-field microscopy is commonly used for sample observations in biological research and medical diagnosis. However, the tilting error induced by the oblique location of the image recorder or the sample, as well as the inclination of the optical path often deteriorates the imaging quality. In order to eliminate the tilting in microscopy, a numerical tilting compensation technique based on wavefront sensing using transport of intensity equation method is proposed in this paper. Both the provided numerical simulations and practical experiments prove that the proposed technique not only accurately determines the tilting angle with simple setup and procedures, but also compensates the tilting error for imaging quality improvement even in the large tilting cases. Considering its simple systems and operations, as well as image quality improvement capability, it is believed the proposed method can be applied for tilting compensation in the optical microscopy.

  16. The diagnosis of internal disc disruption with CT discography

    International Nuclear Information System (INIS)

    Liu Miao; Chen Xingcan; Li Xiaohong; Pan Yongqin

    2008-01-01

    Objective: To study the value of diagnosis for internal disc disruption (IDD)with CT discography(CTD). Methods: 42 discs of 32 patients showing no disc herniation on CT or MRI, but suffering from chronic low back pain, were undertaken CTD to work out the types of CTD with correlation between contrast medium dosages and the induction of pain. Results: CTD demonstrated 4 types of IDD which was individually correlated with the contrast dosages and induced pain; furthermore the dosages for positive and negative disc cases showed significant differece (P<0.01). Conclusions: CTD can show the direct sign of internal disc disruption, providing more information than conventional discography. (authors)

  17. Performance verification of focus variation and confocal microscopes measuring tilted ultra-fine surfaces

    DEFF Research Database (Denmark)

    Quagliotti, Danilo; Baruffi, Federico; Tosello, Guido

    2016-01-01

    The behaviour of two optical instruments, scilicet a laser scanning confocal microscope and a focus-variation microscope, was investigated considering measurements of tilted surfaces. The measured samples were twelve steel artefacts for mould surface finish reference, covering Sa roughness...... parameter in the range (101—103) nm. The 3D surface texture parameters considered were Sa, Sq and Sdq. The small working distance of the confocal microscope objectives influenced the measurement setup, preventing from selecting a high tilting angle. The investigation was carried out comparing measurements...... of flat surfaces (0° tilt) with measurements of 12.5° tilted surfaces. The confocal microscope results showed a high sensitivity to tilting due to the laser beam reflection on the metal surfaces. The focus variation microscope results were more robust with respect to the considered angular variation...

  18. Thermal analysis on motorcycle disc brake geometry

    Science.gov (United States)

    W. M. Zurin W., S.; Talib, R. J.; Ismail, N. I.

    2017-08-01

    Braking is a phase of slowing and stop the movement of motorcycle. During braking, the frictional heat was generated and the energy was ideally should be faster dissipated to surrounding to prevent the built up of the excessive temperature which may lead to brake fluid vaporization, thermoelastic deformation at the contact surface, material degradation and failure. In this paper, solid and ventilated type of motorcycle disc brake are being analyse using Computational Fluid Dynamic (CFD) software. The main focus of the analysis is the thermal behaviour during braking for solid and ventilated disc brake. A comparison between both geometries is being discussed to determine the better braking performance in term of temperature distribution. It is found that ventilated disc brake is having better braking performance in terms of heat transfer compare to solid disc.

  19. Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahn, Hyoun Suk; Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ disc were assessed. Lateral or medial disc displacement was also evaluated on cornal images. Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 disc. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality

  20. Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

    Science.gov (United States)

    Wood, Scott J.; Serrador, Jorge M.; Black, F. Owen; Rupert,Angus H.; Schlegel, Todd T.

    2004-01-01

    The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor

  1. Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials.

    Science.gov (United States)

    Schildhauer, Thomas A; Robie, Bruce; Muhr, Gert; Köller, Manfred

    2006-07-01

    Evaluation of bacterial adhesion to pure tantalum and tantalum-coated stainless steel versus commercially pure titanium, titanium alloy (Ti-6Al-4V), and grit-blasted and polished stainless steel. Experimental in vitro cell culture study using Staphylococcus aureus and Staphylococcus epidermidis to evaluate qualitatively and quantitatively bacterial adherence to metallic implants. A bacterial adhesion assay was performed by culturing S. aureus (ATCC 6538) and S. epidermidis (clinical isolate) for one hour with tantalum, tantalum-coated stainless steel, titanium, titanium alloy, grit-blasted and polished stainless steel metallic implant discs. Adhered living and dead bacteria were stained using a 2-color fluorescence assay. Adherence was then quantitatively evaluated by fluorescence microscopy and digital image processing. Qualitative adherence of the bacteria was analyzed with a scanning electron microscope. The quantitative data were related to the implant surface roughness (Pa-value) as measured by confocal laser scanning microscopy. Bacterial adherence of S. aureus varied significantly (p = 0.0035) with the type of metallic implant. Pure tantalum presented with significantly (p titanium alloy, polished stainless steel, and tantalum-coated stainless steel. Furthermore, pure tantalum had a lower, though not significantly, adhesion than commercially pure titanium and grit-blasted stainless steel. Additionally, there was a significantly higher S. aureus adherence to titanium alloy than to commercially pure titanium (p = 0.014). S. epidermidis adherence was not significantly different among the tested materials. There was no statistically significant correlation between bacterial adherence and surface roughness of the tested implants. Pure tantalum presents with a lower or similar S. aureus and S. epidermidis adhesion when compared with commonly used materials in orthopedic implants. Because bacterial adhesion is an important predisposing factor in the development of

  2. Adjacent level effects of bi level disc replacement, bi level fusion and disc replacement plus fusion in cervical spine--a finite element based study.

    Science.gov (United States)

    Faizan, Ahmad; Goel, Vijay K; Biyani, Ashok; Garfin, Steven R; Bono, Christopher M

    2012-03-01

    Studies delineating the adjacent level effect of single level disc replacement systems have been reported in literature. The aim of this study was to compare the adjacent level biomechanics of bi-level disc replacement, bi-level fusion and a construct having adjoining level disc replacement and fusion system. In total, biomechanics of four models- intact, bi level disc replacement, bi level fusion and fusion plus disc replacement at adjoining levels- was studied to gain insight into the effects of various instrumentation systems on cranial and caudal adjacent levels using finite element analysis (73.6N+varying moment). The bi-level fusion models are more than twice as stiff as compared to the intact model during flexion-extension, lateral bending and axial rotation. Bi-level disc replacement model required moments lower than intact model (1.5Nm). Fusion plus disc replacement model required moment 10-25% more than intact model, except in extension. Adjacent level motions, facet loads and endplate stresses increased substantially in the bi-level fusion model. On the other hand, adjacent level motions, facet loads and endplate stresses were similar to intact for the bi-level disc replacement model. For the fusion plus disc replacement model, adjacent level motions, facet loads and endplate stresses were closer to intact model rather than the bi-level fusion model, except in extension. Based on our finite element analysis, fusion plus disc replacement procedure has less severe biomechanical effects on adjacent levels when compared to bi-level fusion procedure. Bi-level disc replacement procedure did not have any adverse mechanical effects on adjacent levels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Possibilities of reconstruction and implant-prosthetic rehabilitation following mandible resection

    Directory of Open Access Journals (Sweden)

    Konstantinović Vitomir S.

    2013-01-01

    Full Text Available Introduction. Mandible reconstruction is still very challenging for surgeons. Mandible defects could be the consequence of ablative surgery for malignancies, huge jaw cysts, infection and trauma. Segmental resection of the mandible may compromise orofacial function and often lead to patients psychological disorders. Despite very frequent use of microvascular flaps, autogenous bone grafts are still very reliable technique for mandible reconstruction. Comprehensive therapy means not only mandible reconstruction, but prosthodontic rehabilitation supported by dental implants, which can significantly improve patients quality of life. The aim of this paper was to evaluate possible techniques of mandible reconstruction and to present a patient who had been submitted to mandible resection and reconstruction with autogenous iliac bone graft and prosthodontic rehabilitation with fixed denture anchoraged by disc-shaped implants in early loading protocol. Case report. Mandible reconstruction was performed simultaneously with resection. Autogenous iliac bone graft was taken, reshaped and placed in two parts, to the required optimal contour of the mandible. After graft consolidation, decision was made for prosthodontics rehabilitation with fixed dentures supported by implants. In addition to the standard preoperative procedures, planning was done based on a biomodel gained by rapid prototyping after CT scan. It offered a real 3D planning to obtain a proper shape, dimension and the position of implants. Conclusion. If bone dimensions of a reconstructed mandible are insufficient, like in the presented case, the use of basal osseointegrated implants may be a method of choice. Avoiding bone augmentation procedures, as well as early loading protocol for this type of implants, shorten the total rehabilitation time, which is very convenient for patients. Fixed denture supported by dental implants is the best solution for comprehensive rehabilitation after mandible

  4. A novel method of measuring spatial rotation angle using MEMS tilt sensors

    International Nuclear Information System (INIS)

    Cao, Jian’an; Zhu, Xin; Zhang, Leping; Wu, Hao

    2017-01-01

    This paper presents a novel method of measuring spatial rotation angle with a dual-axis micro-electro-mechanical systems tilt sensor. When the sensor is randomly mounted on the surface of the rotating object, there are three unpredictable and unknown mounting position parameters: α , the sensor’s swing angle on the measuring plane; β , the angle between the rotation axis and the horizontal plane; and γ , the angle between the measuring plane and the rotation axis. Thus, the sensor’s spatial rotation model is established to describe the relationship between the measuring axis, rotation axis, and horizontal plane, and the corresponding analytical equations are derived. Furthermore, to eliminate the deviation caused by the uncertain direction of the rotation axis, an extra perpendicularly mounted, single-axis tilt sensor is combined with the dual-axis tilt sensor, forming a three-axis tilt sensor. Then, by measuring the sensors’ three tilts and solving the model’s equations, the object’s spatial rotation angle is obtained. Finally, experimental results show that the developed tilt sensor is capable of measuring spatial rotation angle in the range of  ±180° with an accuracy of 0.2° if the angle between the rotation axis and the horizontal plane is less than 75°. (paper)

  5. Isolated Optic Disc Tuberculosis

    Science.gov (United States)

    Mansour, Ahmad M.; Tabbara, Khalid F.; Tabbarah, Zuhair

    2015-01-01

    We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation. PMID:26483675

  6. Isolated Optic Disc Tuberculosis

    Directory of Open Access Journals (Sweden)

    Ahmad M. Mansour

    2015-09-01

    Full Text Available We present a healthy male subject who developed progressive visual loss in the left eye initially diagnosed as optic neuritis. Upon suspicion of infectious etiology, testing was positive for tuberculosis. There were no signs or symptoms of active systemic tuberculosis infection. The patient responded swiftly to antimycobacterial therapy with return of vision and resolution of disc swelling. Positive purified protein derivative skin test, negative chest radiograph, negative systemic workup, negative workup for other causes of unilateral optic neuritis and quick response to mycobacterial therapy reaffirm the entity of isolated optic disc tuberculosis similar to isolated choroidal tuberculosis without systemic manifestation.

  7. Auto fluorescence of intervertebral disc tissue: a new diagnostic tool.

    Science.gov (United States)

    Hoell, T; Huschak, G; Beier, A; Hüttmann, G; Minkus, Y; Holzhausen, H J; Meisel, H J

    2006-08-01

    The paper reports on auto fluorescence phenomena of inter-vertebral human discs. It systematically investigates the auto fluorescence effects of ex vivo disc specimen and reports on surgical cases to demonstrate the potential value of the new method. The paper offers biologic explanations of the phenomenon and discusses the potential value of the UV auto fluorescence technique as a diagnostic tool. Intra- and postoperative observations are made by a surgical microscope with an integrated UV light source. Quantitative measurements were carried out using a photon counter and a spectrometer ex vivo. The auto fluorescence phenomenon allows the differentiation of traumatized and degenerated disc tissue intraoperatively in some cases, it allows the differentiation of bony and collagen endplate in cervical disc surgery. The source of the auto fluorescent light emission are amino acids of the collagen molecules. The proteoglycan components and the liquid components of the disc do not show relevant auto fluorescence. Emission wavelength of disc material is equivalent to color perception. It differs due to different collagen composition of the intervertebral disc components from yellow-green to blue-green and can be visualized in situ by naked eye.UV-auto fluorescence of inter-vertebral discs is a new clinical tool that has the potential to differentiate disc material from the anatomical surrounding, to distinguish between different fractions of the disc and to give information on the quality and status of the disc material. Since the technology has just emerged, it needs further investigations to quantify the clinical observations reported in this paper.

  8. Angiogenesis in the degeneration of the lumbar intervertebral disc

    OpenAIRE

    David, Gh; Ciurea, AV; Iencean, SM; Mohan, A

    2010-01-01

    The goal of the study is to show the histological and biochemical changes that indicate the angiogenesis of the intervertebral disc in lumbar intervertebral disc hernia and the existence of epidemiological correlations between these changes and the risk factors of lumbar intervertebral disc hernia, as well as the patient's quality of life (QOL). We have studied 50 patients aged between 18 and 73 years old, who have undergone lumbar intervertebral disc hernia surgery, making fibroblast growth ...

  9. Lumbar disc herniation in patients with chronic backache.

    Science.gov (United States)

    Ali, Asghar; Khan, Shahbaz Ali; Aurangzeb, Ahsan; Ahmed, Ehtisham; Ali, Gohar; Muhammad, Gul; Mehmood, Shakir

    2013-01-01

    Low back pain with or without lower extremity pain is the most common problem among chronic pain disorders with significant economic, social, and health impact. This study was conducted to determine the frequency of lumbar disc herniation and its different levels, among patients with chronic backache. This cross sectional study was conducted in the department of Neurosurgery, Ayub Medical College Abbottabad from January 2011 to January 2013. All the patients presenting with chronic low backache of either gender above the age 14 years were included in the study. Magnetic resonance imaging (MRI) was done in all the patients included in the study to look for lumbar disc herniation. A total of 477 patients with chronic low backache were included in the study out of which 274 (57.4%) were males. Age of the patients ranged from 19 to 75 (39.92 +/- 12.31) years. Out of 477 patients 38 (7.9%) had significant radiological evidence of disc prolapse at lumbar vertebral levels, with 26 (9.5%) males and 12 (5.9%) females. Among these 38 patients with inter-vertebral disc, 20 (52.6%) of patients had disc herniation at L5-S1, 15 (39.5%) at L4-L5, 2 (5.26%) cases at L3-L4 level and only one case (2.6%) had the involvement of L2-L3 level. No cases of L1-L2 disc prolapse were found. Patients with chronic backache can have inter-vertebral lumbar disc prolapsed disease. Middle age group are more affected by lumbar disc disease especially at the lower lumbar regions.

  10. Radiographic identification of ingested disc batteries

    International Nuclear Information System (INIS)

    Maves, M.D.

    1986-01-01

    Recently, the hazards by posed the accidental ingestion and impaction of small disc batteries have been widely publicized in the medical and lay press. These foreign bodies, when lodged in the esophagus, leak a caustic solution of 26 to 45% sodium or potassium hydroxide which can cause a burn injury to the esophagus in a very short period of time. Because of the considerable clinical morbidity and mortality from this foreign body, it becomes imperative for the radiologist to quickly and accurately identify disc batteries on plain radiographs. This communication offers a series of radiologic signs important in the identification of disc batteries demonstrate a double density shadow due to the bilaminar structure of the battery. On lateral view, the edges of most disc batteries are round and again present a step-off at the junction of the cathode and anode. These findings are differentiated from the more common esophageal foreign body of a coin which does not have a double density on frontal projection, has a much sharper edge and no visible stepoff. (orig.)

  11. Fundamental study on articular disc with magnetic resonance imagings

    International Nuclear Information System (INIS)

    Chiba, Toyokazu

    1993-01-01

    In order to establish criteria of reading MRI of the temporomandibular joint, a morphological comparison between MRI and the section, and an observation of the articular disc associated with the opening were made. Five temporomandibular joints isolated from 3 human cadavers were subjected to MRI, and sections were prepared to examine criteria of reading MRI. In 20 male adults, 40 temporomandibular joints underwent MRI in three conditions of the intercuspal position, 10 and 20 mm opening positions, and the kinetics of the articular disc were examined. External feature of the head of mandible and that of the articular fossa, the articular tubercule and the postglenoid process were outlined in a row of blacks. The articular disc was outlined in a row of dark ashen areas of the anterior band, the intermediate region, and the posterior band. In the intercuspal position, the head of mandible was rarely covered with the articular disc, and being situated postero-inferiorly, at the most rear point of the posterior band of the articular disc. In the 10 mm-opening position, the head of mandible was practically covered with the articular disc. In the 20 mm-opening position, the intermediate region of the articular disc, and the head of mandible were situated in an approximate position. Quantitative movement of the articular disc was slower than that of the head of mandible. Comparison of various points of the articular disc revealed that movements of the anterior and posterior band varied almost proportionally to the opening distance, but with lesser movement of the intermediate region. (author)

  12. Monitoring of Cyclic Steam Stimulation by Inversion of Surface Tilt Measurements

    Science.gov (United States)

    Maharramov, M.; Zoback, M. D.

    2014-12-01

    Temperature and pressure changes associated with the cyclic steam simulation (CSS) used in heavy oil production from sands are accompanied by significant deformation. Inversion of geomechanical data may provide a potentially powerful reservoir monitoring tool where geomechanical effects are significant. Induced pore pressure changes can be inverted from measurable surface deformations by solving an inverse problem of poroelasticity. In this work, we apply this approach to estimating pore pressure changes from surface tilt measurements at a heavy oil reservoir undergoing cyclic steam simulation. Steam was injected from November 2007 through January 2008. Surface tilt measurements were collected from 25 surface tilt stations during this period. The injection ran in two overlapping phases: Phase 1 ran from the beginning of the injection though mid-December, and Phase 2 overlapped with Phase 1 and ran through the beginning of January. During Phase 1 steam was injected in the western part of the reservoir, followed by injection in the eastern part in Phase 2. The pore pressure evolution was inverted from daily tilt measurements using regularized constrained least squares fitting, the results are shown on the plot. Estimated induced pore pressure change (color scale), observed daily incremental tilts (green arrows) and modeled daily incremental tilts (red arrows) are shown in three panels corresponding to two and five weeks of injection, and the end of injection period. DGPS measurements available for a single location were used as an additional inversion constraint. The results indicate that the pore pressure increase in the reservoir follows the same pattern as the steam injection, from west to east. This qualitative behaviour is independent of the amount of regularization, indirectly validating our inversion approach. Patches of lower pressure appear to be stable with regard to regularization and may provide valuable insight into the efficiency of steam injection

  13. CT reconstruction technique in lumbar intraneuroforaminal disc herniation

    International Nuclear Information System (INIS)

    Volle, E.; Claussen, C.; Kern, A.; Stoltenburg, G.

    1988-01-01

    The CT appearance of the lumbar neural foramina and contents is described in detail and compared to histopathological specimens. Direct axial scans with secondary sagittal, coronal and paraxial reconstruction series of slices of the neuralforamen were derived from lumbar spine examination of fifty normal adults. These normal parameters were then used to evaluate and subdivide 20 patients with disc herniation involving the neuralforamen. The new paraxial reformation was able to show an intraneuroforaminal disc involvement. CT-reformation technique and operative results in intraneuroforaminal disc herniation correspond in 80%. This improvement in preoperative diagnosis demonstrates to the neurosurgeon the full extent of disc herniation and results in an optimized operative approach. (orig.)

  14. CT reconstruction technique in lumbar intraneuroforaminal disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Volle, E.; Claussen, C.; Kern, A.; Stoltenburg, G.

    1988-04-01

    The CT appearance of the lumbar neural foramina and contents is described in detail and compared to histopathological specimens. Direct axial scans with secondary sagittal, coronal and paraxial reconstruction series of slices of the neuralforamen were derived from lumbar spine examination of fifty normal adults. These normal parameters were then used to evaluate and subdivide 20 patients with disc herniation involving the neuralforamen. The new paraxial reformation was able to show an intraneuroforaminal disc involvement. CT-reformation technique and operative results in intraneuroforaminal disc herniation correspond in 80%. This improvement in preoperative diagnosis demonstrates to the neurosurgeon the full extent of disc herniation and results in an optimized operative approach.

  15. Cervical disc hernia operations through posterior laminoforaminotomy.

    Science.gov (United States)

    Yolas, Coskun; Ozdemir, Nuriye Guzin; Okay, Hilmi Onder; Kanat, Ayhan; Senol, Mehmet; Atci, Ibrahim Burak; Yilmaz, Hakan; Coban, Mustafa Kemal; Yuksel, Mehmet Onur; Kahraman, Umit

    2016-01-01

    The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years). Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%). On control examinations, there was no finding of instability or cervical kyphosis. Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  16. Tilted Bianchi type I dust fluid cosmological model in general relativity

    Indian Academy of Sciences (India)

    Tilted Bianchi type I dust fluid cosmological model in general relativity ... In this paper, we have investigated a tilted Bianchi type I cosmological model filled with dust of perfect fluid in general relativity. ... Pramana – Journal of Physics | News ...

  17. Studies on the surface modification of TiN coatings using MEVVA ion implantation with selected metallic species

    International Nuclear Information System (INIS)

    Ward, L.P.; Purushotham, K.P.; Manory, R.R.

    2016-01-01

    Highlights: • Reduced surface roughness was observed after ion implantation. • W implantation increased residual stress. • Reduced friction and wear accompanied Mo implantation. • Mo implanted layer was more resistant to breakdown during wear testing. • Ion implantation effects can be complex on various implanting species properties. - Abstract: Improvement in the performance of TiN coatings can be achieved using surface modification techniques such as ion implantation. In the present study, physical vapor deposited (PVD) TiN coatings were implanted with Cr, Zr, Nb, Mo and W using the metal evaporation vacuum arc (MEVVA) technique at a constant nominal dose of 4 × 10 16 ions cm −2 for all species. The samples were characterized before and after implantation, using Rutherford backscattering (RBS), glancing incident angle X-ray diffraction (GIXRD), atomic force microscopy (AFM) and optical microscopy. Friction and wear studies were performed under dry sliding conditions using a pin-on-disc CSEM Tribometer at 1 N load and 450 m sliding distance. A reduction in the grain size and surface roughness was observed after implantation with all five species. Little variation was observed in the residual stress values for all implanted TiN coatings, except for W implanted TiN which showed a pronounced increase in compressive residual stress. Mo-implanted samples showed a lower coefficient of friction and higher resistance to breakdown during the initial stages of testing than as-received samples. Significant reduction in wear rate was observed after implanting with Zr and Mo ions compared with unimplanted TiN. The presence of the Ti 2 N phase was observed with Cr implantation.

  18. Spiral density waves and vertical circulation in protoplanetary discs

    Science.gov (United States)

    Riols, A.; Latter, H.

    2018-06-01

    Spiral density waves dominate several facets of accretion disc dynamics - planet-disc interactions and gravitational instability (GI) most prominently. Though they have been examined thoroughly in two-dimensional simulations, their vertical structures in the non-linear regime are somewhat unexplored. This neglect is unwarranted given that any strong vertical motions associated with these waves could profoundly impact dust dynamics, dust sedimentation, planet formation, and the emissivity of the disc surface. In this paper, we combine linear calculations and shearing box simulations in order to investigate the vertical structure of spiral waves for various polytropic stratifications and wave amplitudes. For sub-adiabatic profiles, we find that spiral waves develop a pair of counter-rotating poloidal rolls. Particularly strong in the non-linear regime, these vortical structures issue from the baroclinicity supported by the background vertical entropy gradient. They are also intimately connected to the disc's g modes which appear to interact non-linearly with the density waves. Furthermore, we demonstrate that the poloidal rolls are ubiquitous in gravitoturbulence, emerging in the vicinity of GI spiral wakes, and potentially transporting grains off the disc mid-plane. Other than hindering sedimentation and planet formation, this phenomena may bear on observations of the disc's scattered infrared luminosity. The vortical features could also impact on the turbulent dynamo operating in young protoplanetary discs subject to GI, or possibly even galactic discs.

  19. Collimation of particle beams from thick accretion discs

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, M [N. Copernicus Astronomical Center, Warszawa (Poland); Wilson, D B [Cambridge Univ. (UK). Inst. of Astronomy

    1981-11-01

    The acceleration and collimation of particle beams in the funnel of thick accretion discs is studied in the approximation that the flow is optically thin. Such flows can be collimated to within approximately 0.1 radians by sufficiently thick discs. The flow cannot convert more than a small fraction of the disc's (super-Eddington) luminosity into the energy flow of a narrow beam without being optically thick.

  20. Combined Influence of Visual Scene and Body Tilt on Arm Pointing Movements: Gravity Matters!

    Science.gov (United States)

    Scotto Di Cesare, Cécile; Sarlegna, Fabrice R.; Bourdin, Christophe; Mestre, Daniel R.; Bringoux, Lionel

    2014-01-01

    Performing accurate actions such as goal-directed arm movements requires taking into account visual and body orientation cues to localize the target in space and produce appropriate reaching motor commands. We experimentally tilted the body and/or the visual scene to investigate how visual and body orientation cues are combined for the control of unseen arm movements. Subjects were asked to point toward a visual target using an upward movement during slow body and/or visual scene tilts. When the scene was tilted, final pointing errors varied as a function of the direction of the scene tilt (forward or backward). Actual forward body tilt resulted in systematic target undershoots, suggesting that the brain may have overcompensated for the biomechanical movement facilitation arising from body tilt. Combined body and visual scene tilts also affected final pointing errors according to the orientation of the visual scene. The data were further analysed using either a body-centered or a gravity-centered reference frame to encode visual scene orientation with simple additive models (i.e., ‘combined’ tilts equal to the sum of ‘single’ tilts). We found that the body-centered model could account only for some of the data regarding kinematic parameters and final errors. In contrast, the gravity-centered modeling in which the body and visual scene orientations were referred to vertical could explain all of these data. Therefore, our findings suggest that the brain uses gravity, thanks to its invariant properties, as a reference for the combination of visual and non-visual cues. PMID:24925371

  1. Edge detection of magnetic anomalies using analytic signal of tilt angle (ASTA)

    Science.gov (United States)

    Alamdar, K.; Ansari, A. H.; Ghorbani, A.

    2009-04-01

    Magnetic is a commonly used geophysical technique to identify and image potential subsurface targets. Interpretation of magnetic anomalies is a complex process due to the superposition of multiple magnetic sources, presence of geologic and cultural noise and acquisition and positioning error. Both the vertical and horizontal derivatives of potential field data are useful; horizontal derivative, enhance edges whereas vertical derivative narrow the width of anomaly and so locate source bodies more accurately. We can combine vertical and horizontal derivative of magnetic field to achieve analytic signal which is independent to body magnetization direction and maximum value of this lies over edges of body directly. Tilt angle filter is phased-base filter and is defined as angle between vertical derivative and total horizontal derivative. Tilt angle value differ from +90 degree to -90 degree and its zero value lies over body edge. One of disadvantage of this filter is when encountering with deep sources the detected edge is blurred. For overcome this problem many authors introduced new filters such as total horizontal derivative of tilt angle or vertical derivative of tilt angle which Because of using high-order derivative in these filters results may be too noisy. If we combine analytic signal and tilt angle, a new filter termed (ASTA) is produced which its maximum value lies directly over body edge and is easer than tilt angle to delineate body edge and no complicity of tilt angle. In this work new filter has been demonstrated on magnetic data from an area in Sar- Cheshme region in Iran. This area is located in 55 degree longitude and 32 degree latitude and is a copper potential region. The main formation in this area is Andesith and Trachyandezite. Magnetic surveying was employed to separate the boundaries of Andezite and Trachyandezite from adjacent area. In this regard a variety of filters such as analytic signal, tilt angle and ASTA filter have been applied which

  2. Metallicity gradient of the thick disc progenitor at high redshift

    Science.gov (United States)

    Kawata, Daisuke; Allende Prieto, Carlos; Brook, Chris B.; Casagrande, Luca; Ciucă, Ioana; Gibson, Brad K.; Grand, Robert J. J.; Hayden, Michael R.; Hunt, Jason A. S.

    2018-01-01

    We have developed a novel Markov Chain Monte Carlo chemical 'painting' technique to explore possible radial and vertical metallicity gradients for the thick disc progenitor. In our analysis, we match an N-body simulation to the data from the Apache Point Observatory Galactic Evolution Experiment survey. We assume that the thick disc has a constant scaleheight and has completed its formation at an early epoch, after which time radial mixing of its stars has taken place. Under these assumptions, we find that the initial radial metallicity gradient of the thick disc progenitor should not be negative, but either flat or even positive, to explain the current negative vertical metallicity gradient of the thick disc. Our study suggests that the thick disc was built-up in an inside-out and upside-down fashion, and older, smaller and thicker populations are more metal poor. In this case, star-forming discs at different epochs of the thick disc formation are allowed to have different radial metallicity gradients, including a negative one, which helps to explain a variety of slopes observed in high-redshift disc galaxies. This scenario helps to explain the positive slope of the metallicity-rotation velocity relation observed for the Galactic thick disc. On the other hand, radial mixing flattens the slope of an existing gradient.

  3. Twenty-degree-tilt radiography for evaluation of lateral humeral condylar fracture in children

    International Nuclear Information System (INIS)

    Imada, Hideaki; Tanaka, Ryuji; Itoh, Yohei; Kishi, Kazuhiko

    2010-01-01

    To investigate the efficacy of '20 -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 -tilt A-P radiographs. The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 -tilt A-P radiography (9.3 ± 3.6 mm and 5.6 ± 2.5 mm) was significantly wider than that measured by the conventional method (6.8 ± 4.1 mm and 2.0 ± 1.5 mm), which may influence treatment. Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment. (orig.)

  4. Early Poststroke Rehabilitation Using a Robotic Tilt-Table Stepper and Functional Electrical Stimulation

    Directory of Open Access Journals (Sweden)

    Alexey N. Kuznetsov

    2013-01-01

    Full Text Available Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES and robotic tilt-table training (ROBO against tilt-table training alone (control. A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age years, days after stroke were assigned to 30 days of ROBO-FES (, ROBO (, or control ( in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped % during robot training. In 52% of controls mean arterial pressure decreased by %. ROBO-FES increased leg strength by points, ROBO by more than control (, . CBFV increased in both robotic groups more than in controls (. Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone.

  5. [Evaluation of psychological fear in children undergoing head-up tilt test].

    Science.gov (United States)

    Chu, Wei-Hong; Wu, Li-Jia; Wang, Cheng; Lin, Ping; Li, Fang; Zhu, Li-Ping; Ran, Jing; Zou, Run-Mei; Liu, De-Yu

    2014-03-01

    To investigate the effects of different tilt angles of head-up tilt test (HUTT) and different responses to HUTT on the psychological fear in children undergoing the test. HUTT was performed on children with unexplained syncope or pre-syncope (107 cases: 52 males and 55 females), aged 5.5-17.8 years (mean 12.0±2.8 years). All subjects were randomly assigned to undergo HUTT at an angle of 60°, 70° or 80°; the negative cases underwent sublingual nitroglycerin-provocation HUTT at the same tilt angle. The Wong-Baker Faces Pain Rating Scale was used for self-assessment of psychological fear in subjects during HUTT at the end point of the test. The positive rate, hemodynamic changes and distribution of response types showed no significant differences between children at tilt angles of 60°, 70° and 80° (P>0.05). The greater the tilt angle, the higher the degree of psychological fear in children undergoing the test, but there were no significant differences between them (P>0.05). The degree of psychological fear in children who showed a positive response to HUTT (n=76) was significantly higher than that in children who showed a negative response (n=31) (Pfear in children undergoing the test, and the degree of psychological fear increases in children tested at tilt angles from 60° to 80°, but the differences have no statistical significance. A positive response to HUTT can significantly increase the psychological fear in children.

  6. Upper thoracic-spine disc degeneration in patients with cervical pain.

    Science.gov (United States)

    Arana, Estanislao; Martí-Bonmatí, Luis; Mollá, Enrique; Costa, Salvador

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6 +/- 14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P < 0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated ( P = 0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together ( P < 0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms.

  7. Upper thoracic-spine disc degeneration in patients with cervical pain

    Energy Technology Data Exchange (ETDEWEB)

    Arana, Estanislao; Marti-Bonmati, Luis; Costa, Salvador [Department of Radiology, Clinica Quiron, Avda Blasco Ibanez 14, 46010, Valencia (Spain); Molla, Enrique [Department of Radiology, Clinica Quiron, Avda Blasco Ibanez 14, 46010, Valencia (Spain); Department of Morphological Sciences, University of Valencia, Valencia (Spain)

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6{+-}14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P<0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated (P=0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together (P<0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms. (orig.)

  8. Human disc degeneration is associated with increased MMP 7 expression.

    Science.gov (United States)

    Le Maitre, C L; Freemont, A J; Hoyland, J A

    2006-01-01

    During intervertebral disc (IVD) degeneration, normal matrix synthesis decreases and degradation of disc matrix increases. A number of proteases that are increased during disc degeneration are thought to be involved in its pathogenesis. Matrix metalloproteinase 7 (MMP 7) (Matrilysin, PUMP-1) is known to cleave the major matrix molecules found within the IVD, i.e., the proteoglycan aggrecan and collagen type II. To date, however, it is not known how its expression changes with degeneration or its exact location. We investigated the localization of MMP 7 in human, histologically graded, nondegenerate, degenerated and prolapsed discs to ascertain whether MMP 7 is up-regulated during disc degeneration. Samples of human IVD tissue were fixed in neutral buffered formalin, embedded in paraffin, and sections stained with hematoxylin and eosin to score the degree of morphological degeneration. Immunohistochemistry was performed to localize MMP 7 in 41 human IVDs with varying degrees of degeneration. We found that the chondrocyte-like cells of the nucleus pulposus and inner annulus fibrosus were MMP 7 immunopositive; little immunopositivity was observed in the outer annulus. Nondegenerate discs showed few immunopositive cells. A significant increase in the proportion of MMP 7 immunopositive cells was seen in the nucleus pulposus of discs classified as showing intermediate levels of degeneration and a further increase was seen in discs with severe degeneration. Prolapsed discs showed more MMP 7 immunopositive cells compared to nondegenerated discs, but fewer than those seen in cases of severe degeneration.

  9. Upper thoracic-spine disc degeneration in patients with cervical pain

    International Nuclear Information System (INIS)

    Arana, Estanislao; Marti-Bonmati, Luis; Costa, Salvador; Molla, Enrique

    2004-01-01

    To study the relationship of upper thoracic spine degenerative disc contour changes on MR imaging in patients with neck pain. The relation between upper thoracic and cervical spine degenerative disc disease is not well established. One hundred and fifty-six patients referred with cervical pain were studied. There were 73 women and 77 men with a mean age of 48.6±14.6 years (range, 19 to 83 years). All MR studies were performed with a large 23-cm FOV covering at least from the body of T4 to the clivus. Discs were coded as normal, protrusion/bulge or extrusion. Degenerative thoracic disc contour changes were observed in 13.4% of patients with cervical pain. T2-3 was the most commonly affected level of the upper thoracic spine, with 15 bulge/protrusions and one extrusion. Upper degenerative thoracic disc contour changes presented in older patients than the cervical levels (Student-Newman-Keuls test, P<0.001). Degenerative disc contour changes at the C7-T1, T1-2, T2-3 and T3-4 levels were significantly correlated (P=0.001), but unrelated to any other disc disease, patient's gender or age. Degenerative cervical disc disease was closely related together (P<0.001), but not with any thoracic disc. A statistically significant relation was found within the upper thoracic discs, reflecting common pathoanatomical changes. The absence of relation to cervical segments is probably due to differences in their pathomechanisms. (orig.)

  10. Coherent field propagation between tilted planes.

    Science.gov (United States)

    Stock, Johannes; Worku, Norman Girma; Gross, Herbert

    2017-10-01

    Propagating electromagnetic light fields between nonparallel planes is of special importance, e.g., within the design of novel computer-generated holograms or the simulation of optical systems. In contrast to the extensively discussed evaluation between parallel planes, the diffraction-based propagation of light onto a tilted plane is more burdensome, since discrete fast Fourier transforms cannot be applied directly. In this work, we propose a quasi-fast algorithm (O(N 3  log N)) that deals with this problem. Based on a proper decomposition into three rotations, the vectorial field distribution is calculated on a tilted plane using the spectrum of plane waves. The algorithm works on equidistant grids, so neither nonuniform Fourier transforms nor an explicit complex interpolation is necessary. The proposed algorithm is discussed in detail and applied to several examples of practical interest.

  11. 3D single-molecule super-resolution microscopy with a tilted light sheet.

    Science.gov (United States)

    Gustavsson, Anna-Karin; Petrov, Petar N; Lee, Maurice Y; Shechtman, Yoav; Moerner, W E

    2018-01-09

    Tilted light sheet microscopy with 3D point spread functions (TILT3D) combines a novel, tilted light sheet illumination strategy with long axial range point spread functions (PSFs) for low-background, 3D super-localization of single molecules as well as 3D super-resolution imaging in thick cells. Because the axial positions of the single emitters are encoded in the shape of each single-molecule image rather than in the position or thickness of the light sheet, the light sheet need not be extremely thin. TILT3D is built upon a standard inverted microscope and has minimal custom parts. The result is simple and flexible 3D super-resolution imaging with tens of nm localization precision throughout thick mammalian cells. We validate TILT3D for 3D super-resolution imaging in mammalian cells by imaging mitochondria and the full nuclear lamina using the double-helix PSF for single-molecule detection and the recently developed tetrapod PSFs for fiducial bead tracking and live axial drift correction.

  12. PATHOGENESIS OF OPTIC DISC EDEMA IN RAISED INTRACRANIAL PRESSURE

    Science.gov (United States)

    Hayreh, Sohan Singh

    2015-01-01

    Optic disc edema in raised intracranial pressure was first described in 1853. Ever since, there has been a plethora of controversial hypotheses to explain its pathogenesis. I have explored the subject comprehensively by doing basic, experimental and clinical studies. My objective was to investigate the fundamentals of the subject, to test the validity of the previous theories, and finally, based on all these studies, to find a logical explanation for the pathogenesis. My studies included the following issues pertinent to the pathogenesis of optic disc edema in raised intracranial pressure: the anatomy and blood supply of the optic nerve, the roles of the sheath of the optic nerve, of the centripetal flow of fluids along the optic nerve, of compression of the central retinal vein, and of acute intracranial hypertension and its associated effects. I found that, contrary to some previous claims, an acute rise of intracranial pressure was not quickly followed by production of optic disc edema. Then, in rhesus monkeys, I produced experimentally chronic intracranial hypertension by slowly increasing in size space-occupying lesions, in different parts of the brain. Those produced raised cerebrospinal fluid pressure (CSFP) and optic disc edema, identical to those seen in patients with elevated CSFP. Having achieved that, I investigated various aspects of optic disc edema by ophthalmoscopy, stereoscopic color fundus photography and fluorescein fundus angiography, and light microscopic, electron microscopic, horseradish peroxidase and axoplasmic transport studies, and evaluated the effect of opening the sheath of the optic nerve on the optic disc edema. This latter study showed that opening the sheath resulted in resolution of optic disc edema on the side of the sheath fenestration, in spite of high intracranial CSFP, proving that a rise of CSFP in the sheath was the essential pre-requisite for the development of optic disc edema. I also investigated optic disc edema with

  13. Herniated Cervical Disc

    Science.gov (United States)

    ... are sometimes prescribed for more severe arm and neck pain because of their very powerful anti-inflammatory effect. ... caused by a herniated cervical disc. However, some neck pain may persist. Most patients respond well to discectomy; ...

  14. In vitro dermal and epidermal cellular response to titanium alloy implants fabricated with electron beam melting.

    Science.gov (United States)

    Springer, Jessica Collins; Harrysson, Ola L A; Marcellin-Little, Denis J; Bernacki, Susan H

    2014-10-01

    Transdermal osseointegrated prostheses (TOPs) are emerging as an alternative to socket prostheses. Electron beam melting (EBM) is a promising additive manufacturing technology for manufacture of custom, freeform titanium alloy (Ti6Al4V) implants. Skin ongrowth for infection resistance and mechanical stability are critically important to the success of TOP, which can be influenced by material composition and surface characteristics. We assessed viability and proliferation of normal human epidermal keratinocytes (NHEK) and normal human dermal fibroblasts (NHDF) on several Ti6Al4V surfaces: solid polished commercial, solid polished EBM, solid unpolished EBM and porous unpolished EBM. Cell proliferation was evaluated at days 2 and 7 using alamarBlue(®) and cell viability was analyzed with a fluorescence-based live-dead assay after 1 week. NHDF and NHEK were viable and proliferated on all Ti6Al4V surfaces. NHDF proliferation was highest on commercial and EBM polished surfaces. NHEK was highest on commercial polished surfaces. All EBM Ti6Al4V discs exhibited an acceptable biocompatibility profile compared to solid Ti6Al4V discs from a commercial source for dermal and epidermal cells. EBM may be considered as an option for fabrication of custom transdermal implants. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Magnetic fields in giant planet formation and protoplanetary discs

    Science.gov (United States)

    Keith, Sarah Louise

    2015-12-01

    Protoplanetary discs channel accretion onto their host star. How this is achieved is critical to the growth of giant planets which capture their massive gaseous atmosphere from the surrounding flow. Theoretical studies find that an embedded magnetic field could power accretion by hydromagnetic turbulence or torques from a large-scale field. This thesis presents a study of the inuence of magnetic fields in three key aspects of this process: circumplanetary disc accretion, gas flow across gaps in protoplanetary discs, and magnetic-braking in accretion discs. The first study examines the conditions needed for self-consistent accretion driven by magnetic fields or gravitational instability. Models of these discs typically rely on hydromagnetic turbulence as the source of effective viscosity. However, magnetically coupled,accreting regions may be so limited that the disc may not support sufficient inflow. An improved Shakura-Sunyaev ? disc is used to calculate the ionisation fraction and strength of non-ideal effects. Steady magnetically-driven accretion is limited to the thermally ionised, inner disc so that accretion in the remainder of the disc is time-dependent. The second study addresses magnetic flux transport in an accretion gap evacuated by a giant planet. Assuming the field is passively drawn along with the gas, the hydrodynamical simulation of Tanigawa, Ohtsuki & Machida (2012) is used for an a posteriori analysis of the gap field structure. This is used to post-calculate magnetohydrodynamical quantities. This assumption is self-consistent as magnetic forces are found to be weak, and good magnetic coupling ensures the field is frozen into the gas. Hall drift dominates across much of the gap, with the potential to facilitate turbulence and modify the toroidal field according to the global field orientation. The third study considers the structure and stability of magnetically-braked accretion discs. Strong evidence for MRI dead-zones has renewed interest in

  16. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    Science.gov (United States)

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Characteristics of X-ray photons in tilted incident laser-produced plasma

    International Nuclear Information System (INIS)

    Wang Ruirong; Chen Weimin; Xie Dongzhu

    2008-01-01

    Characteristics of X-ray and spout direction of heat plasma flow were studied on Shenguang-II laser facility. Using of pinhole X-ray camera, X-ray photons from the plasma of aluminum (Al) irradiated by 1.053 μm laser, was measured and analysed. It is observed that the spatial distribution of X-ray photons in Al plasma for tilted irradiation is symmetic at the center of the target. The spout direction of heat plasma flow is inferred by the distribution contour of X-ray photons. the experimental results show that the spout direction of heat plasma flow is normal to target plane and the output intensity of X-ray photons does not increase significantly for tilted laser incidence. Uniformity of laser energy deposition is improved by superposing tilted incident and laser perpendicularly incident laser. At the same time, it is found that the conversion efficiency from the tilted incident laser energy to X-ray photons of laser-produced plasma is decreased. (authors)

  18. Analysis of an Assemblage of Discs Employing Interactive Graphics.

    Science.gov (United States)

    1980-12-01

    facilitate the program’s efficiency. Indeed, the ulsabilitv of tie distinct element method is pred icated on ef f ic ielt Irogramming techniques...paragraphs. Any subsequent user of DISC should not necessarily feel bound to this scheme. 33. At the outset of writing DISC, it was decided that a disc

  19. Utility of Digital Stereo Images for Optic Disc Evaluation

    Science.gov (United States)

    Ying, Gui-shuang; Pearson, Denise J.; Bansal, Mayank; Puri, Manika; Miller, Eydie; Alexander, Judith; Piltz-Seymour, Jody; Nyberg, William; Maguire, Maureen G.; Eledath, Jayan; Sawhney, Harpreet

    2010-01-01

    Purpose. To assess the suitability of digital stereo images for optic disc evaluations in glaucoma. Methods. Stereo color optic disc images in both digital and 35-mm slide film formats were acquired contemporaneously from 29 subjects with various cup-to-disc ratios (range, 0.26–0.76; median, 0.475). Using a grading scale designed to assess image quality, the ease of visualizing optic disc features important for glaucoma diagnosis, and the comparative diameters of the optic disc cup, experienced observers separately compared the primary digital stereo images to each subject's 35-mm slides, to scanned images of the same 35-mm slides, and to grayscale conversions of the digital images. Statistical analysis accounted for multiple gradings and comparisons and also assessed image formats under monoscopic viewing. Results. Overall, the quality of primary digital color images was judged superior to that of 35-mm slides (P digital color images were mostly equivalent to the scanned digitized images of the same slides. Color seemingly added little to grayscale optic disc images, except that peripapillary atrophy was best seen in color (P digital over film images was maintained under monoscopic viewing conditions. Conclusions. Digital stereo optic disc images are useful for evaluating the optic disc in glaucoma and allow the application of advanced image processing applications. Grayscale images, by providing luminance distinct from color, may be informative for assessing certain features. PMID:20505199

  20. On the formation of exponential discs

    International Nuclear Information System (INIS)

    Yoshii, Yuzuru; Sommer-Larsen, Jesper

    1989-01-01

    Spiral galaxy discs are characterized by approximately exponential surface luminosity profiles. In this paper the evolutionary equations for a star-forming, viscous disc are solved analytically or semi-analytically. It is shown that approximately exponential stellar surface density profiles result if the viscous time-scale t ν is comparable to the star-formation time scale t * everywhere in the disc. The analytical solutions are used to illuminate further on the issue of why the above mechanism leads to resulting exponential stellar profiles under certain conditions. The sensitivity of the solution to variations of various parameters are investigated and show that the initial gas surface density distribution has to be fairly regular in order that final exponential stellar surface density profiles result. (author)

  1. Developments in intervertebral disc disease research: pathophysiology, mechanobiology, and therapeutics.

    Science.gov (United States)

    Weber, Kathryn T; Jacobsen, Timothy D; Maidhof, Robert; Virojanapa, Justin; Overby, Chris; Bloom, Ona; Quraishi, Shaheda; Levine, Mitchell; Chahine, Nadeen O

    2015-03-01

    Low back pain is a leading cause of disability worldwide and the second most common cause of physician visits. There are many causes of back pain, and among them, disc herniation and intervertebral disc degeneration are the most common diagnoses and targets for intervention. Currently, clinical treatment outcomes are not strongly correlated with diagnoses, emphasizing the importance for characterizing more completely the mechanisms of degeneration and their relationships with symptoms. This review covers recent studies elucidating cellular and molecular changes associated with disc mechanobiology, as it relates to degeneration and regeneration. Specifically, we review findings on the biochemical changes in disc diseases, including cytokines, chemokines, and proteases; advancements in disc disease diagnostics using imaging modalities; updates on studies examining the response of the intervertebral disc to injury; and recent developments in repair strategies, including cell-based repair, biomaterials, and tissue engineering. Findings on the effects of the omega-6 fatty acid, linoleic acid, on nucleus pulposus tissue engineering are presented. Studies described in this review provide greater insights into the pathogenesis of disc degeneration and may define new paradigms for early or differential diagnostics of degeneration using new techniques such as systemic biomarkers. In addition, research on the mechanobiology of disease enriches the development of therapeutics for disc repair, with potential to diminish pain and disability associated with disc degeneration.

  2. Appearance of Keplerian discs orbiting Kerr superspinars

    Energy Technology Data Exchange (ETDEWEB)

    Stuchlik, Zdenek; Schee, Jan, E-mail: zdenek.stuchlik@fpf.slu.c, E-mail: jan.schee@fpf.slu.c [Institute of Physics, Faculty of Philosophy and Science, Silesian University in Opava, Bezrucovo nam. 13, Opava (Czech Republic)

    2010-11-07

    We study optical phenomena related to the appearance of Keplerian accretion discs orbiting Kerr superspinars predicted by string theory. The superspinar exterior is described by standard Kerr naked singularity geometry breaking the black hole limit on the internal angular momentum (spin). We construct local photon escape cones for a variety of orbiting sources that enable us to determine the superspinars silhouette in the case of distant observers. We show that the superspinar silhouette depends strongly on the assumed edge where the external Kerr spacetime is joined to the internal spacetime governed by string theory and significantly differs from the black hole silhouette. The appearance of the accretion disc is strongly dependent on the value of the superspinar spin in both their shape and frequency shift profile. Apparent extension of the disc grows significantly with the growing spin, while the frequency shift grows with the descending spin. This behaviour differs substantially from the appearance of discs orbiting black holes enabling thus, at least in principle, to distinguish clearly the Kerr superspinars and black holes. In vicinity of a Kerr superspinar the non-escaped photons have to be separated to those captured by the superspinar and those being trapped in its strong gravitational field leading to self-illumination of the disc that could even influence its structure and cause self-reflection effect of radiation of the disc. The amount of trapped photons grows with descending superspinar spin. We thus can expect significant self-illumination effects in the field of Kerr superspinars with near-extreme spin a {approx} 1.

  3. Normal modes of Bardeen discs

    International Nuclear Information System (INIS)

    Verdaguer, E.

    1983-01-01

    The short wavelength normal modes of self-gravitating rotating polytropic discs in the Bardeen approximation are studied. The discs' oscillations can be seen in terms of two types of modes: the p-modes whose driving forces are pressure forces and the r-modes driven by Coriolis forces. As a consequence of differential rotation coupling between the two takes place and some mixed modes appear, their properties can be studied under the assumption of weak coupling and it is seen that they avoid the crossing of the p- and r-modes. The short wavelength analysis provides a basis for the classification of the modes, which can be made by using the properties of their phase diagrams. The classification is applied to the large wavelength modes of differentially rotating discs with strong coupling and to a uniformly rotating sequence with no coupling, which have been calculated in previous papers. Many of the physical properties and qualitative features of these modes are revealed by the analysis. (author)

  4. Power diagrams and interaction processes for unions of discs

    DEFF Research Database (Denmark)

    Møller, Jesper; Helisova, Katarina

    We study a flexible class of finite disc process models with interaction between the discs. We let U denote the random set given by the union of discs, and use for the disc process an exponential family density with the canonical sufficient statistic only depending on geometric properties of U......, becomes useful for handling the problem of edge effects when only U is observed within a bounded observation window. The power tessellation and its dual graph become major tools when establishing inclusion-exclusion formulae, formulae for computing geometric characteristics of U, and stability properties...

  5. Power diagrams and interaction processes for unions of discs

    DEFF Research Database (Denmark)

    Møller, Jesper; Helisova, Katerina

    2008-01-01

     We study a flexible class of finite-disc process models with interaction between the discs. We let U denote the random set given by the union of discs, and use for the disc process an exponential family density with the canonical sufficient statistic depending only on geometric properties of U......, becomes useful for handling the problem of edge effects when only U is observed within a bounded observation window. The power tessellation and its dual graph become major tools when establishing inclusion-exclusion formulae, formulae for computing geometric characteristics of U, and stability properties...

  6. The Application of Normal Stress Reduction Function in Tilt Tests for Different Block Shapes

    Science.gov (United States)

    Kim, Dong Hyun; Gratchev, Ivan; Hein, Maw; Balasubramaniam, Arumugam

    2016-08-01

    This paper focuses on the influence of the shapes of rock cores, which control the sliding or toppling behaviours in tilt tests for the estimation of rock joint roughness coefficients (JRC). When the JRC values are estimated by performing tilt tests, the values are directly proportional to the basic friction of the rock material and the applied normal stress on the sliding planes. Normal stress obviously varies with the shape of the sliding block, and the basic friction angle is also affected by the sample shapes in tilt tests. In this study, the shapes of core blocks are classified into three representative shapes and those are created using plaster. Using the various shaped artificial cores, a set of tilt tests is carried out to identify the shape influences on the normal stress and the basic friction angle in tilt tests. The test results propose a normal stress reduction function to estimate the normal stress for tilt tests according to the sample shapes based on Barton's empirical equation. The proposed normal stress reduction functions are verified by tilt tests using artificial plaster joints and real rock joint sets. The plaster joint sets are well matched and cast in detailed printed moulds using a 3D printing technique. With the application of the functions, the obtained JRC values from the tilt tests using the plaster samples and the natural rock samples are distributed within a reasonable JRC range when compared with the measured values.

  7. [Surgical treatment of thoracic disc herniation].

    Science.gov (United States)

    Hrabálek, L; Kalita, O; Langová, K

    2010-08-01

    The aim of this study was to compare the efficiency of different surgical approaches to thoracic disc herniation, and to show the role of segmental fusion and selection of an appropriate microsurgical decompression technique for the successful outcome of surgery. A group of 27 patients, 10 men and 17 women, between 31 and 70 years (average age, 49.33 years) were included in this prospective study. They underwent surgery for thoracic degeneration disc disease in the period from June 1994 to August 2008. In all patients, the severity of myelopathy was assessed using the grading Frankel system and JOA score, axial and radicular pain intensity was evaluated with VAS and ODI rating systems. The diagnosis was established on the basis of thoracic spine radiography, thoracic spine MRI and a CT scan of the segment. A total of 30 thoracic segments, in the range of Th4/Th5 to Th12/L1, were indicated for surgery. Localisation of the hernia was medial at 19 segments, mediolateral at three and lateral at eight segments. Soft disc herniation was found in 17 cases and hard disc protrusion at the remaining 13 segments. Surgery for significant myelopathy was carried out in 23 patients and for pain in four patients. According to the surgical procedure used, the patients were allocated to two groups: group A comprised 10 patients treated without disc replacement through a laminectomy or a costotransversectomy exposure, and group B consisted of 17 patients undergo- ing intersomatic fusion via a thoracotomy. Clinical and radiographic examinations were made at regular intervals for at least 1 year of follow-up. The results of clinical assessment, including JOA scores, JOA Recovery Rate, VAS scores at rest and after exercise and ODI, were statistically analysed for each group and compared. There was a statistically significant difference in JOA evaluation of myelopathy between the groups in group A, the mean JOA score declined from 7.9 to 7.0, i.e., -0.9 point, while in group B it

  8. Clinical evaluation of disc battery ingestion in children.

    Science.gov (United States)

    Mirshemirani, AliReza; Khaleghnejad-Tabari, Ahmad; Kouranloo, Jaefar; Sadeghian, Naser; Rouzrokh, Mohsen; Roshanzamir, Fatolah; Razavi, Sajad; Sayary, Ali Akbar; Imanzadeh, Farid

    2012-04-01

    BACKGROUND The purpose of this study was to evaluate the characteristics, management, and outcomes of disc battery ingestion in children. METHODS We reviewed the medical records of children admitted to Mofid Children's Hospital due to disc battery ingestion from January 2006 to January 2010. Clear history, clinical symptoms and results of imaging studies revealed diagnosis of disc battery ingestion in suspected patients. The clinical data reviewed included age, gender, clinical manifestation, radiologic findings, location of disc battery, duration of ingestion, endoscopic results and surgical treatment. RESULTS We found 22 cases (11 males and 11 females) of disc battery ingestion with a mean age of 4.3 years (range: 9 months to 12 years). Common symptoms were vomiting, cough, dysphagia, and dyspnea. The mean duration of ingestion was 2.7 days (4 hours to 1.5 months). A total of 19 patients had histories of disc battery ingestion, but three cases referred with the above symptoms, and the batteries were accidentally found by x-ray. Only three cases had batteries impacted in the esophagus. Twelve batteries were removed endoscopically, 6 batteries spontaneously passed through the gastrointestinal (GI) tract within 5 to 7 days, and 4 patients underwent surgery due to complications: 3 due to tracheo-esophageal fistula (TEF) and 1 due to intestinal perforation. There was no mortality in our study. CONCLUSION Most cases of disc battery ingestion run uneventful courses, but some may be complicated. If the battery lodges in the esophagus, emergency endoscopic management is necessary. However, once in the stomach, it will usually pass through the GI tract.

  9. Indigenous development of rupture discs for FBTR (Paper No. 028)

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, Chander; Anandkumar, V.; Seetharaman, V.

    1987-02-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water-steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. As an import substitution of the costly items for the FBTR Project, development of the rupture disc assemblies has been in progress at Indira Gandhi Centre for Atomic Research, Kalpakkam. Reverse buckling knife blade concept with stainless steel disc has been taken up for development. Hydroforming process without any die has been selected for disc fabrication. One rupture disc assembly required for steam generator has been tested in sodium satisfactorily. (author). 4 tables, 5 figs

  10. Comparison of optimum tilt angles of solar collectors determined at yearly, seasonal and monthly levels

    International Nuclear Information System (INIS)

    Despotovic, Milan; Nedic, Vladimir

    2015-01-01

    Highlights: • Optimum yearly, biannual, seasonal, monthly, and daily tilt angles were found. • Energy collected per square meter is compared for ten different scenarios. • Four seasonal scenarios and two biannual scenarios were considered. • It is sufficient to adjust tilt angles only twice per year. - Abstract: The amount of energy that is transformed in solar collector depends on its tilt angle with respect to horizontal plane and orientation of the collector. In this article the optimum tilt angle of solar collectors for Belgrade, which is located at the latitude of 44°47′N is determined. The optimum tilt angle was found by searching for the values for which the solar radiation on the collector surface is maximum for a particular day or a specific period. In that manner the yearly, biannual, seasonal, monthly, fortnightly, and daily optimum tilt angles are determined. Annually collected energy per square meter of tilted surface is compared for ten different scenarios. In addition, these optimum tilt angles are used to calculate the amount of energy on the surface of PV panels that could be installed at the roof of the building. The results show that for observed case study placing the panels at yearly, seasonal and monthly optimum tilt angles, would yield increasing yearly amount of collected energy by factor of 5.98%, 13.55%, and 15.42% respectively compared to energy that could be collected by putting the panels at current roofs’ surface angles

  11. Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors.

    Science.gov (United States)

    Gutiérrez, Sergio; Comiskey, Charles A; Luo, Zong-Ping; Pupello, Derek R; Frankle, Mark A

    2008-12-01

    Evaluations of functional outcomes of reverse shoulder arthroplasty have revealed variable improvements in the range of motion and high rates of scapular notching. The purpose of this study was to systematically examine the impact of surgical factors (location of the glenosphere on the glenoid and tilt angle of the glenosphere on the glenoid) and implant-related factors (implant size, center-of-rotation offset, and humeral neck-shaft angle) on impingement-free abduction motion. A computer model was developed to virtually simulate abduction/adduction motion and its dependence on five surgical and implant-related factors. Three conditions were tested for each factor, resulting in a total of 243 simulated combinations. The overall motion was determined from 0 degrees of abduction until maximum abduction, which would be limited by impingement of the humerosocket on the scapula. In those combinations in which 0 degrees of abduction could not be achieved, the adduction deficit was recorded. The largest average increase in the range of impingement-free abduction motion resulted from a more lateral center-of-rotation offset: the average increase was 31.9 degrees with a change in the center-of-rotation offset from 0 to 10 mm, and this change resulted in an increase in abduction motion in eighty of the eighty-one combinations. The position of the glenosphere on the glenoid was associated with the second largest average increase in abduction motion (28.1 degrees when the glenosphere position was changed from superior to inferior, with the change resulting in an increase in seventy-one of the eighty-one combinations). These factors were followed by glenosphere tilt, humeral neck-shaft angle, and prosthetic size in terms of their effects on abduction motion. The largest effect in terms of avoiding an adduction deficit was provided by a humeral neck-shaft angle of 130 degrees (the deficit was avoided in forty-nine of the eighty-one combinations in which this angle was used

  12. Maintaining Low Voiding Solder Die Attach for Power Die While Minimizing Die Tilt

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, Randy; Peterson, Kenneth A.

    2015-10-01

    This paper addresses work to minimize voiding and die tilt in solder attachment of a large power die, measuring 9.0 mm X 6.5 mm X 0.1 mm (0.354” x 0.256” x 0.004”), to a heat spreader. As demands for larger high power die continue, minimizing voiding and die tilt is of interest for improved die functionality, yield, manufacturability, and reliability. High-power die generate considerable heat, which is important to dissipate effectively through control of voiding under high thermal load areas of the die while maintaining a consistent bondline (minimizing die tilt). Voiding was measured using acoustic imaging and die tilt was measured using two different optical measurement systems. 80Au-20Sn solder reflow was achieved using a batch vacuum solder system with optimized fixturing. Minimizing die tilt proved to be the more difficult of the two product requirements to meet. Process development variables included tooling, weight and solder preform thickness.

  13. Use of an Android application "clinometer" for measurement of head down tilt given during subarachnoid block.

    Science.gov (United States)

    Dixit, R B; Neema, M M

    2016-01-01

    Head down tilt is given to patients after sub arachnoid block for adjustment of height of block. However, the amount of tilt given is subjective and cannot be documented. We used an android application named "clinometer" to measure exact degree of tilt given by anesthesiologists as their routine practice. This observational study, at a medical college hospital, was done in 130 patients given sub arachnoid block for lower abdominal surgeries. We observed and documented vital data of patients and measured tilt given by application "clinometer." We observed that the application was easy to use and measured tilt each time. The result obtained can be documented, digitally saved and transferred. In 130 patients studied, we observed incidence of degree of tilt as follows: 6-8° tilt in 38 patients (29.23%), 8-10 in 36 patients (27.69%), 10-12 in 30 patients (23.08%), 12-14 in 12 patients (9.23%) and 14-16° tilt in 14 patients (10.77%). Use of application was received with enthusiasm by practicing anesthesiologists. Various possible uses of this application are discussed.

  14. CFD Numerical Simulation of Biodiesel Synthesis in a Spinning Disc Reactor

    Directory of Open Access Journals (Sweden)

    Wen Zhuqing

    2015-03-01

    Full Text Available In this paper a two-disc spinning disc reactor for intensified biodiesel synthesis is described and numerically simulated. The reactor consists of two flat discs, located coaxially and parallel to each other with a gap of 0.2 mm between the discs. The upper disc is located on a rotating shaft while the lower disc is stationary. The feed liquids, triglycerides (TG and methanol are introduced coaxially along the centre line of rotating disc and stationary disc. Fluid hydrodynamics in the reactor for synthesis of biodiesel from TG and methanol in the presence of a sodium hydroxide catalyst are simulated, using convection-diffusion-reaction species transport model by the CFD software ANSYS©Fluent v. 13.0. The effect of the upper disc’s spinning speed is evaluated. The results show that the rotational speed increase causes an increase of TG conversion despite the fact that the residence time decreases. Compared to data obtained from adequate experiments, the model shows a satisfactory agreement.

  15. Silver nanoparticle-enriched diamond-like carbon implant modification as a mammalian cell compatible surface with antimicrobial properties

    Science.gov (United States)

    Gorzelanny, Christian; Kmeth, Ralf; Obermeier, Andreas; Bauer, Alexander T.; Halter, Natalia; Kümpel, Katharina; Schneider, Matthias F.; Wixforth, Achim; Gollwitzer, Hans; Burgkart, Rainer; Stritzker, Bernd; Schneider, Stefan W.

    2016-01-01

    The implant-bone interface is the scene of competition between microorganisms and distinct types of tissue cells. In the past, various strategies have been followed to support bony integration and to prevent bacterial implant-associated infections. In the present study we investigated the biological properties of diamond-like carbon (DLC) surfaces containing silver nanoparticles. DLC is a promising material for the modification of medical implants providing high mechanical and chemical stability and a high degree of biocompatibility. DLC surface modifications with varying silver concentrations were generated on medical-grade titanium discs, using plasma immersion ion implantation-induced densification of silver nanoparticle-containing polyvinylpyrrolidone polymer solutions. Immersion of implants in aqueous liquids resulted in a rapid silver release reducing the growth of surface-bound and planktonic Staphylococcus aureus and Staphylococcus epidermidis. Due to the fast and transient release of silver ions from the modified implants, the surfaces became biocompatible, ensuring growth of mammalian cells. Human endothelial cells retained their cellular differentiation as indicated by the intracellular formation of Weibel-Palade bodies and a high responsiveness towards histamine. Our findings indicate that the integration of silver nanoparticles into DLC prevents bacterial colonization due to a fast initial release of silver ions, facilitating the growth of silver susceptible mammalian cells subsequently. PMID:26955791

  16. Computing Decoupled Residuals for Compact Disc Players

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Andersen, Palle

    2006-01-01

    a pair of residuals generated by Compact Disc Player. However, these residuals depend on the performance of position servos in the Compact Disc Player. In other publications of the same authors a pair of decoupled residuals is derived. However, the computation of these alternative residuals has been...

  17. A comparison of cup-to-disc ratio estimates by fundus biomicroscopy and stereoscopic optic disc photography in the Tema Eye Survey.

    Science.gov (United States)

    Mwanza, J C; Grover, D S; Budenz, D L; Herndon, L W; Nolan, W; Whiteside-de Vos, J; Hay-Smith, G; Bandi, J R; Bhansali, K A; Forbes, L A; Feuer, W J; Barton, K

    2017-08-01

    PurposeTo determine if there are systematic differences in cup-to-disc ratio (CDR) grading using fundus biomicroscopy compared to stereoscopic disc photograph reading.MethodsThe vertical cup-to-disc ratio (VCDR) and horizontal cup-to-disc ratio (HCDR) of 2200 eyes (testing set) were graded by glaucoma subspecialists through fundus biomicroscopy and by a reading center using stereoscopic disc photos. For validation, the glaucoma experts also estimated VCDR and HCDR using stereoscopic disc photos in a subset of 505 eyes that they had assessed biomicroscopically. Agreement between grading methods was assessed with Bland-Altman plots.ResultsIn both sets, photo reading tended to yield small CDRs marginally larger, but read large CDRs marginally smaller than fundus biomicroscopy. The mean differences in VCDR and HCDR were 0.006±0.18 and 0.05±0.18 (testing set), and -0.053±0.23 and -0.028±0.21 (validation set), respectively. The limits of agreement were ~0.4, which is twice as large as the cutoff of clinically significant CDR difference between methods. CDR estimates differed by 0.2 or more in 33.8-48.7% between methods.ConclusionsThe differences in CDR estimates between fundus biomicroscopy and stereoscopic optic disc photo reading showed a wide variation, and reached clinically significance threshold in a large proportion of patients, suggesting a poor agreement. Thus, glaucoma should be monitored by comparing baseline and subsequent CDR estimates using the same method rather than comparing photographs to fundus biomicroscopy.

  18. Cervical disc hernia operations through posterior laminoforaminotomy

    Directory of Open Access Journals (Sweden)

    Coskun Yolas

    2016-01-01

    Full Text Available Objective: The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. Materials and Methods: We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. Results: The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years. Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%. On control examinations, there was no finding of instability or cervical kyphosis. Conclusion: Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis.

  19. Bulge Growth Through Disc Instabilities in High-Redshift Galaxies

    Science.gov (United States)

    Bournaud, Frédéric

    The role of disc instabilities, such as bars and spiral arms, and the associated resonances, in growing bulges in the inner regions of disc galaxies have long been studied in the low-redshift nearby Universe. There it has long been probed observationally, in particular through peanut-shaped bulges (Chap. 14 10.1007/978-3-319-19378-6_14"). This secular growth of bulges in modern disc galaxies is driven by weak, non-axisymmetric instabilities: it mostly produces pseudobulges at slow rates and with long star-formation timescales. Disc instabilities at high redshift (z > 1) in moderate-mass to massive galaxies (1010 to a few 1011 M⊙ of stars) are very different from those found in modern spiral galaxies. High-redshift discs are globally unstable and fragment into giant clumps containing 108-9 M⊙ of gas and stars each, which results in highly irregular galaxy morphologies. The clumps and other features associated to the violent instability drive disc evolution and bulge growth through various mechanisms on short timescales. The giant clumps can migrate inward and coalesce into the bulge in a few 108 years. The instability in the very turbulent media drives intense gas inflows toward the bulge and nuclear region. Thick discs and supermassive black holes can grow concurrently as a result of the violent instability. This chapter reviews the properties of high-redshift disc instabilities, the evolution of giant clumps and other features associated to the instability, and the resulting growth of bulges and associated sub-galactic components.

  20. On the evolution of vortices in massive protoplanetary discs

    Science.gov (United States)

    Pierens, Arnaud; Lin, Min-Kai

    2018-05-01

    It is expected that a pressure bump can be formed at the inner edge of a dead-zone, and where vortices can develop through the Rossby Wave Instability (RWI). It has been suggested that self-gravity can significantly affect the evolution of such vortices. We present the results of 2D hydrodynamical simulations of the evolution of vortices forming at a pressure bump in self-gravitating discs with Toomre parameter in the range 4 - 30. We consider isothermal plus non-isothermal disc models that employ either the classical β prescription or a more realistic treatment for cooling. The main aim is to investigate whether the condensating effect of self-gravity can stabilize vortices in sufficiently massive discs. We confirm that in isothermal disc models with Q ≳ 15, vortex decay occurs due to the vortex self-gravitational torque. For discs with 3≲ Q ≲ 7, the vortex develops gravitational instabilities within its core and undergoes gravitational collapse, whereas more massive discs give rise to the formation of global eccentric modes. In non-isothermal discs with β cooling, the vortex maintains a turbulent core prior to undergoing gravitational collapse for β ≲ 0.1, whereas it decays if β ≥ 1. In models that incorpore both self-gravity and a better treatment for cooling, however, a stable vortex is formed with aspect ratio χ ˜ 3 - 4. Our results indicate that self-gravity significantly impacts the evolution of vortices forming in protoplanetary discs, although the thermodynamical structure of the vortex is equally important for determining its long-term dynamics.

  1. The use of genetic algorithms to model protoplanetary discs

    Science.gov (United States)

    Hetem, Annibal; Gregorio-Hetem, Jane

    2007-12-01

    The protoplanetary discs of T Tauri and Herbig Ae/Be stars have previously been studied using geometric disc models to fit their spectral energy distribution (SED). The simulations provide a means to reproduce the signatures of various circumstellar structures, which are related to different levels of infrared excess. With the aim of improving our previous model, which assumed a simple flat-disc configuration, we adopt here a reprocessing flared-disc model that assumes hydrostatic, radiative equilibrium. We have developed a method to optimize the parameter estimation based on genetic algorithms (GAs). This paper describes the implementation of the new code, which has been applied to Herbig stars from the Pico dos Dias Survey catalogue, in order to illustrate the quality of the fitting for a variety of SED shapes. The star AB Aur was used as a test of the GA parameter estimation, and demonstrates that the new code reproduces successfully a canonical example of the flared-disc model. The GA method gives a good quality of fit, but the range of input parameters must be chosen with caution, as unrealistic disc parameters can be derived. It is confirmed that the flared-disc model fits the flattened SEDs typical of Herbig stars; however, embedded objects (increasing SED slope) and debris discs (steeply decreasing SED slope) are not well fitted with this configuration. Even considering the limitation of the derived parameters, the automatic process of SED fitting provides an interesting tool for the statistical analysis of the circumstellar luminosity of large samples of young stars.

  2. Octahedral tilt transitions in the relaxor ferroelectric Na1/2Bi1/2TiO3

    International Nuclear Information System (INIS)

    Meyer, Kai-Christian; Gröting, Melanie; Albe, Karsten

    2015-01-01

    The kinetics of octahedral tilt transitions in the lead-free relaxor material sodium bismuth titanate Na 1/2 Bi 1/2 TiO 3 (NBT) is investigated by electronic structure calculations within density functional theory. Energy barriers for transitions between tetragonal, rhombohedral and orthorhombic tilts in cation configurations with [001]- and [111]-order on the A-sites are determined by nudged elastic band calculations. By tilting entire layers of octahedra simultaneously we find that the activation energy is lower for structures with 001-order compared to such with 111-order. The energetic coupling between differently tilted layers is, however, negligibly small. By introducing a single octahedral defect we create local tilt disorder and find that the deformation energy of the neighboring octahedra is less in a rhombohedral than in a tetragonal structure. By successively increasing the size of clusters of orthorhombic defects in a rhombohedral matrix with 001-order, we determine a critical cluster size of about 40 Å . Thus groups of about ten octahedra can be considered as nuclei for polar nanoregions, which are the cause of the experimentally observed relaxor behavior of NBT. - Graphical abstract: Nine orthorhombic oxygen octahedral tilt defects in a rhombohedral tilt configuration. - Highlights: • Chemical order influences energy barriers of octahedral tilt transitions. • The octahedral deformation energy is lower in rhombohedral phases. • Tilt defect clusters are more likely in rhombohedral structures. • Tilt defect clusters can act as nuclei for polar nanoregions

  3. Reducing friction in tilting-pad bearings by the use of enclosed recesses

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2008-01-01

    A three-dimensional thermoelastohydrodynamic model is applied to the analysis of tilting-pad bearings with spherical pivots and equipped with deep recesses in the high-pressure regions. A potential for a 10-20% reduction in the friction loss compared to conventional plain bearing pads is documented....... Design suggestions minimizing the power loss are given for various length-to-width ratios. The tilting angle in the sliding direction is more sensitive to correct positioning of the pivot point than conventional bearing pads. Improving the performance by equipping a tilting-pad bearing with a deep recess...... therefore requires accurate analysis and design of the bearing. Similarly, a high sensitivity perpendicular to the sliding direction suggests that this method of reducing friction is more feasible when using line pivots or spring beds than when using spherical pivots for controlling the tilting angle....

  4. The effect of parental factors in children with large cup-to-disc ratios.

    Directory of Open Access Journals (Sweden)

    Hae-Young Lopilly Park

    Full Text Available To investigate large cup-to-disc ratios (CDR in children and to determine the relationship between parental CDR and clinical characteristics associated with glaucoma.Two hundred thirty six children aged 6 to 12 years with CDR ≥ 0.6 were enrolled in this study. Subjects were classified into two groups based on parental CDR: disc suspect children with disc suspect (CDR ≥0.6 parents and disc suspect children without disc suspect parents. Ocular variables were compared between the two groups.Of the 236 disc suspect children, 100 (42.4% had at least one disc suspect parent. Intraocular pressure (IOP was higher in disc suspect children with disc suspect parents (16.52±2.66 mmHg than in disc suspect children without disc suspect parents (14.38±2.30 mmHg, p = 0.023. In the group with disc suspect parents, vertical CDR significantly correlated with IOP (R = -0.325, p = 0.001, average retinal nerve fiber layer (RNFL thickness (R = -0.319, p = 0.001, rim area (R = -0.740, p = 0.001, and cup volume (R = 0.499, p = 0.001. However, spherical equivalent (R = 0.333, p = 0.001, AL (R = -0.223, p = 0.009, and disc area (R = 0.325, p = 0.001 significantly correlated with vertical CDR in disc suspect children without disc suspect parents, in contrast to those with disc suspect parents. Larger vertical CDR was associated with the presence of disc suspect parents (p = 0.001, larger disc area (p = 0.001, thinner rim area (p = 0.001, larger average CDR (p = 0.001, and larger cup volume (p = 0.021.Family history of large CDR was a significant factor associated with large vertical CDR in children. In children with disc suspect parents, there were significant correlations between IOP and average RNFL thickness and vertical CDR.

  5. The effect of parental factors in children with large cup-to-disc ratios.

    Science.gov (United States)

    Park, Hae-Young Lopilly; Ha, Min Ji; Shin, Sun Young

    2017-01-01

    To investigate large cup-to-disc ratios (CDR) in children and to determine the relationship between parental CDR and clinical characteristics associated with glaucoma. Two hundred thirty six children aged 6 to 12 years with CDR ≥ 0.6 were enrolled in this study. Subjects were classified into two groups based on parental CDR: disc suspect children with disc suspect (CDR ≥0.6) parents and disc suspect children without disc suspect parents. Ocular variables were compared between the two groups. Of the 236 disc suspect children, 100 (42.4%) had at least one disc suspect parent. Intraocular pressure (IOP) was higher in disc suspect children with disc suspect parents (16.52±2.66 mmHg) than in disc suspect children without disc suspect parents (14.38±2.30 mmHg, p = 0.023). In the group with disc suspect parents, vertical CDR significantly correlated with IOP (R = -0.325, p = 0.001), average retinal nerve fiber layer (RNFL) thickness (R = -0.319, p = 0.001), rim area (R = -0.740, p = 0.001), and cup volume (R = 0.499, p = 0.001). However, spherical equivalent (R = 0.333, p = 0.001), AL (R = -0.223, p = 0.009), and disc area (R = 0.325, p = 0.001) significantly correlated with vertical CDR in disc suspect children without disc suspect parents, in contrast to those with disc suspect parents. Larger vertical CDR was associated with the presence of disc suspect parents (p = 0.001), larger disc area (p = 0.001), thinner rim area (p = 0.001), larger average CDR (p = 0.001), and larger cup volume (p = 0.021). Family history of large CDR was a significant factor associated with large vertical CDR in children. In children with disc suspect parents, there were significant correlations between IOP and average RNFL thickness and vertical CDR.

  6. Tilt Precursors before Earthquakes on the San Andreas Fault, California.

    Science.gov (United States)

    Johnston, M J; Mortensen, C E

    1974-12-13

    An array of 14 biaxial shallow-borehole tiltmeters (at 1O(-7) radian sensitivity) has been installed along 85 kilometers of the San Andreas fault during the past year. Earthquake-related changes in tilt have been simultaneously observed on up to four independent instruments. At earthquake distances greater than 10 earthquake source dimensions, there are few clear indications of tilt change. For the four instruments with the longest records (> 10 months), 26 earthquakes have occurred since July 1973 with at least one instrument closer than 10 source dimensions and 8 earthquakes with more than one instrument within that distance. Precursors in tilt direction have been observed before more than 10 earthquakes or groups of earthquakes, and no similar effect has yet been seen without the occurrence of an earthquake.

  7. The Gaia-ESO Survey: the Galactic thick to thin disc transition

    NARCIS (Netherlands)

    Recio-Blanco, A.; de Laverny, P.; Kordopatis, G.; Helmi, A.; Hill, V.; Gilmore, G.; Wyse, R.; Adibekyan, V.; Randich, S.; Asplund, M.; Feltzing, S.; Jeffries, R.; Micela, G.; Vallenari, A.; Alfaro, E.; Allende Prieto, C.; Bensby, T.; Bragaglia, A.; Flaccomio, E.; Koposov, S. E.; Korn, A.; Lanzafame, A.; Pancino, E.; Smiljanic, R.; Jackson, R.; Lewis, J.; Magrini, L.; Morbidelli, L.; Prisinzano, L.; Sacco, G.; Worley, C. C.; Hourihane, A.; Bergemann, M.; Costado, M. T.; Heiter, U.; Joffre, P.; Lardo, C.; Lind, K.; Maiorca, E.

    Aims: The nature of the thick disc and its relation to the thin disc is presently an important subject of debate. In fact, the structural and chemo-dynamical transition between disc populations can be used as a test of the proposed models of Galactic disc formation and evolution. Methods: We used

  8. Can magnetic resonance imaging accurately predict concordant pain provocation during provocative disc injection?

    International Nuclear Information System (INIS)

    Kang, Chang Ho; Kim, Yun Hwan; Kim, Jung Hyuk; Chung, Kyoo Byung; Sung, Deuk Jae; Lee, Sang-Heon; Derby, Richard

    2009-01-01

    To correlate magnetic resonance (MR) image findings with pain response by provocation discography in patients with discogenic low back pain, with an emphasis on the combination analysis of a high intensity zone (HIZ) and disc contour abnormalities. Sixty-two patients (aged 17-68 years) with axial low back pain that was likely to be disc related underwent lumbar discography (178 discs tested). The MR images were evaluated for disc degeneration, disc contour abnormalities, HIZ, and endplate abnormalities. Based on the combination of an HIZ and disc contour abnormalities, four classes were determined: (1) normal or bulging disc without HIZ; (2) normal or bulging disc with HIZ; (3) disc protrusion without HIZ; (4) disc protrusion with HIZ. These MR image findings and a new combined MR classification were analyzed in the base of concordant pain determined by discography. Disc protrusion with HIZ [sensitivity 45.5%; specificity 97.8%; positive predictive value (PPV), 87.0%] correlated significantly with concordant pain provocation (P < 0.01). A normal or bulging disc with HIZ was not associated with reproduction of pain. Disc degeneration (sensitivity 95.4%; specificity 38.8%; PPV 33.9%), disc protrusion (sensitivity 68.2%; specificity 80.6%; PPV 53.6%), and HIZ (sensitivity 56.8%; specificity 83.6%; PPV 53.2%) were not helpful in the identification of a disc with concordant pain. The proposed MR classification is useful to predict a disc with concordant pain. Disc protrusion with HIZ on MR imaging predicted positive discography in patients with discogenic low back pain. (orig.)

  9. Intervertebral disc herniation: prevalence and association with ...

    African Journals Online (AJOL)

    Background: Low back pain is one of the common health problems encountered in life with intervertebral disc herniation being a common cause of its occurrence. Magnetic resonance imaging has emerged the gold standard for diagnosing a herniated disc. Aims and Objectives: To assess the frequency and pattern of ...

  10. Robust control of a compact disc mechanism

    NARCIS (Netherlands)

    Steinbuch, M.; Schootstra, G.; Bosgra, O.H.; Levine, W.S.

    1995-01-01

    A compact disc (CD) player is an optical decoding device that reproduces high-quality audio from a digitally coded signal recorded as a spiral-shaped track on a reflective disc. Apart from the audio application, other optical data systems (CD-ROM, optical data drive) and combined audio/video

  11. Suspected herniated lumbar disc - computed tomography in differential diagnosis of non-disc-related sciatica

    International Nuclear Information System (INIS)

    Weiss, T.; Koehler, D.; Treisch, J.; Claussen, C.; Felix, R.

    1984-01-01

    The most common reason a patient is referred for spinal CT examination is to exclude a ruptured intervertebral disc. Besides nerve root entrapment due to herniated disc, a number of unusual for unexpected conditions have been encountered in the course of CT lumbar spine studies. These include spondylolisthesis, spinal dysraphism, Paget's disease, and inflammatory, neoplastic, or metastatic lesions. The application of spinal (small-circle) target imaging includes the risk to overlook soft tissue lesions that extend beyond the reconstruction circle. Therefore, complete (large-circle) circumferential abdominal scanning is recommended in case of a suspected extraspinal cause of sciatica. (orig.) [de

  12. Suspected herniated lumbar disc - computed tomography in differential diagnosis of non-disc-related sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, T.; Koehler, D.; Treisch, J.; Claussen, C.; Felix, R.

    1984-07-01

    The most common reason a patient is referred for spinal CT examination is to exclude a ruptured intervertebral disc. Besides nerve root entrapment due to herniated disc, a number of unusual or unexpected conditions have been encountered in the course of CT lumbar spine studies. These include spondylolisthesis, spinal dysraphism, Paget's disease, and inflammatory, neoplastic, or metastatic lesions. The application of spinal (small-circle) target imaging includes the risk of overlooking soft tissue lesions that extend beyond the reconstruction circle. Therefore, complete (large-circle) circumferential abdominal scanning is recommended in case of a suspected extraspinal cause of sciatica.

  13. Design of an Annular Disc Subject to Thermomechanical Loading

    Directory of Open Access Journals (Sweden)

    Sergei Alexandrov

    2012-01-01

    Full Text Available Two solutions to design a thin annular disc of variable thickness subject to thermomechanical loading are proposed. It is assumed that the thickness of the disc is everywhere sufficiently small for the stresses to be averaged through the thickness. The state of stress is plane. The initiation of plastic yielding is controlled by Mises yield criterion. The design criterion for one of the solutions proposed requires that the distribution of stresses is uniform over the entire disc. In this case there is a relation between optimal values of the loading parameters at the final stage. The specific shape of the disc corresponds to each pair of such parameters. The other solution is obtained under the additional requirement that the distribution of strains is uniform. This solution exists for the disc of constant thickness at specific values of the loading parameters.

  14. Preliminary Experience with Anterior Interbody Titanium Cage Fusion for Treatment of Cervical Disc Disease

    Directory of Open Access Journals (Sweden)

    Chung-Nan Lin

    2003-05-01

    Full Text Available This study evaluated the efficacy and safety of titanium cage implants in cervical reconstruction to treat cervical spondylosis. Surgical data covered a 4-year period from January 1999 to December 2002 and included 34 consecutive patients, 20 men and 14 women, with ages ranging from 27 to 84 years (mean, 57 years. Patients underwent anterior cervical microdiscectomy followed by interbody fusion with a titanium cage implant (rather than an autogenous iliac crest bone graft at a single level ranging from C3 to C7. Twenty-one patients had a herniated intervertebral disc, nine had degenerative disc disease, and four had previous failed autograft fusion surgery that required revision. At clinical presentation, 26 patients had neck pain, 23 had radiculopathy, and nine had myelopathy. Diagnostic imaging studies included spinal dynamic roentgenography, computerized tomography, and magnetic resonance imaging. Lesions were located at C3-4 in seven cases, C4-5 in 14 cases, C5-6 in nine cases, and C6-7 in four cases. The follow-up period ranged from 7 to 48 months (mean, 26 months. Results revealed that the procedure was technically feasible. There were no intra- or postoperative complications. The most commonly used cage was 9 mm high. Imaging studies showed no cage instability, migration, or pseudarthrosis. Although mild subsidence (< 5 mm was observed in three cases, these patients preserved adequate postoperative cervical lordosis and the subsidence did not preclude a good clinical result. The advantages of this procedure over a similar operation using traditional tricorticate bone graft are: no graft morbidity; shorter operation time (mean time saved, 35 minutes; reduced blood loss (average blood loss, 75 mL; and early postoperative ambulation (mean, 4.7 hospital days. Nearly all patients rapidly lost their neck pain (92%, 24/26 and radicular symptoms (87%, 20/23 after surgery. The recovery rate from myelopathy was 44% (4/9. Progressive bony shield

  15. Biomechanical analysis of the camelid cervical intervertebral disc

    Directory of Open Access Journals (Sweden)

    Dean K. Stolworthy

    2015-01-01

    Full Text Available Chronic low back pain (LBP is a prevalent global problem, which is often correlated with degenerative disc disease. The development and use of good, relevant animal models of the spine may improve treatment options for this condition. While no animal model is capable of reproducing the exact biology, anatomy, and biomechanics of the human spine, the quality of a particular animal model increases with the number of shared characteristics that are relevant to the human condition. The purpose of this study was to investigate the camelid (specifically, alpaca and llama cervical spine as a model of the human lumbar spine. Cervical spines were obtained from four alpacas and four llamas and individual segments were used for segmental flexibility/biomechanics and/or morphology/anatomy studies. Qualitative and quantitative data were compared for the alpaca and llama cervical spines, and human lumbar specimens in addition to other published large animal data. Results indicate that a camelid cervical intervertebral disc (IVD closely approximates the human lumbar disc with regard to size, spinal posture, and biomechanical flexibility. Specifically, compared with the human lumbar disc, the alpaca and llama cervical disc size are approximately 62%, 83%, and 75% with regard to area, depth, and width, respectively, and the disc flexibility is approximately 133%, 173%, and 254%, with regard to range of motion (ROM in axial-rotation, flexion-extension, and lateral-bending, respectively. These results, combined with the clinical report of disc degeneration in the llama lower cervical spine, suggest that the camelid cervical spine is potentially well suited for use as an animal model in biomechanical studies of the human lumbar spine.

  16. MR image findings on advanced internal derangement of the temporomandibular joints. Cases of disc position changed from anterior disc displacement with reduction to without reduction

    International Nuclear Information System (INIS)

    Igarashi, Chinami; Kobayashi, Kaoru; Yuasa, Masao; Imanaka, Masahiro; Yamamoto, Akira

    2005-01-01

    This study was designed to evaluate the suggestion that the clinical findings and MR image findings of anterior disc displacement with reduction cases could not reduce the disc displacement within the follow-up period. We selected 26 joints without remarkable bone changes in the condylar head or glenoid fossa in which reduction disappeared during follow-up. Clinical evaluation focused on temporomandibular pain, trismus, and joint sound. MR imaging was targeted for configuration of articular disc, degree of disc displacement, and condylar head position. Clinical signs observed with progression of the condition were disappearance of joint sound in 12/26 joints (46.1%), temporomandibular pain in 15/26 joints (57.6%), and decreased distance of opening mouth in 19/26 joints (73%). MR image findings were disc configuration changes in 12/26 joints (46.1%), increased degree of anterior displacement of disc in 20/26 joints (76.9%), and condylar head position changes in 9/26 joints (34.6%). It is suggested that the advanced stage of internal derangement is closely associated with the degree of disc displacement. (author)

  17. The anterior tilt of the acromion: radiographic evaluation and correlation with shoulder diseases

    International Nuclear Information System (INIS)

    Prato, N.; Peloso, D.; Franconeri, A.; Tegaldo, G.; Ravera, G.B.; Silvestri, E.; Derchi, L.E.

    1998-01-01

    The aim of this study was to test whether the anterior tilt of the acromion can be objectively evaluated on lateral radiographs, and whether there is a relation between this anatomical feature and the most common shoulder diseases. Lateral radiographs of 15 dried scapulas were performed in neutral position and with 5 of caudal, cranial, anterior and posterior angulations. Two hundred and forty-three shoulders, both asymptomatic and affected by chronic and post-traumatic impingement, calcific tendinitis and instability, were examined by conventional radiography. The presence of rotator-cuff tears was investigated by sonography. A method was elaborated to obtain reproducible lateral radiographs and to determine the acromial tilt angle. Inter- and intraobserver and inter- and intraoperator variations in measurements were evaluated. Variations in tube angulation produced changes in tilt-angle values on dried scapulas. The average tilt angle for the chronic impingement and the instability groups were significantly different from the post-traumatic, calcific tendinitis and control groups. Rotator-cuff tears were significantly more frequent in the chronic impingement group and related to a more acute tilt angle. The inter- and intraobserver variability coefficients were 0.95 and 0.98, whereas the inter- and intraoperator variability coefficients were 0.94 and 0.96, respectively. Conventional radiography using fluoroscopy for positioning is a well-reproducible method for the evaluation of acromial tilt. There is a significant difference in tilt-angle values between some groups of subjects examined, but the lack of specificity limits the clinical importance of such measurement. (orig.)

  18. The anterior tilt of the acromion: radiographic evaluation and correlation with shoulder diseases

    Energy Technology Data Exchange (ETDEWEB)

    Prato, N.; Peloso, D.; Franconeri, A. [Department of Radiology, San Carlo Hospital, Genoa (Italy); Tegaldo, G. [Dept. of Orthopaedic Surgery, San Carlo Hospital, Genoa (Italy); Ravera, G.B. [Inst. of Medical Statistics and Biometry, University of Genoa (Italy); Silvestri, E.; Derchi, L.E. [Inst. of Radiology, University of Genoa (Italy)

    1998-12-01

    The aim of this study was to test whether the anterior tilt of the acromion can be objectively evaluated on lateral radiographs, and whether there is a relation between this anatomical feature and the most common shoulder diseases. Lateral radiographs of 15 dried scapulas were performed in neutral position and with 5 of caudal, cranial, anterior and posterior angulations. Two hundred and forty-three shoulders, both asymptomatic and affected by chronic and post-traumatic impingement, calcific tendinitis and instability, were examined by conventional radiography. The presence of rotator-cuff tears was investigated by sonography. A method was elaborated to obtain reproducible lateral radiographs and to determine the acromial tilt angle. Inter- and intraobserver and inter- and intraoperator variations in measurements were evaluated. Variations in tube angulation produced changes in tilt-angle values on dried scapulas. The average tilt angle for the chronic impingement and the instability groups were significantly different from the post-traumatic, calcific tendinitis and control groups. Rotator-cuff tears were significantly more frequent in the chronic impingement group and related to a more acute tilt angle. The inter- and intraobserver variability coefficients were 0.95 and 0.98, whereas the inter- and intraoperator variability coefficients were 0.94 and 0.96, respectively. Conventional radiography using fluoroscopy for positioning is a well-reproducible method for the evaluation of acromial tilt. There is a significant difference in tilt-angle values between some groups of subjects examined, but the lack of specificity limits the clinical importance of such measurement. (orig.) With 6 figs., 3 tabs., 34 refs.

  19. Analysis of fixed tilt and sun tracking photovoltaic–micro wind based hybrid power systems

    International Nuclear Information System (INIS)

    Sinha, Sunanda; Chandel, S.S.

    2016-01-01

    Graphical abstract: 6 kW_p photovoltaic–micro wind based hybrid power system analysis in a Indian Western Himalayan location. - Highlights: • Power generation by a roof mounted photovoltaic–micro wind hybrid system is explored. • Optimum hybrid configurations using fixed and sun tracking photovoltaic systems are determined. • Analysis of hybrid systems with optimally tilted and different sun tracking systems is presented. • Two axis sun tracking systems are found to generate 4.88–26.29% more energy than fixed tilt system. • Hybrid system installed at optimum tilt angle is found to be cost effective than a sun tracking system. - Abstract: In this study fixed tilt and sun tracking photovoltaic based micro wind hybrid power systems are analyzed along with determining the optimum configurations for a 6 kW_p roof mounted micro wind based hybrid system using fixed and tracking photovoltaic systems to enhance the power generation potential in a low windy Indian hilly terrain with good solar resource. The main objective of the study is to enhance power generation by focusing on photovoltaic component of the hybrid system. A comparative power generation analysis of different configurations of hybrid systems with fixed tilt, monthly optimum tilt, yearly optimum tilt and 6 different sun tracking photovoltaic systems is carried out using Hybrid Optimization Model for Electric Renewables. Monthly and seasonal optimum tilt angles determined for the location vary between 0° and 60° with annual optimum tilt angle as 29.25°. The optimum configurations for all sun tracking systems except for the two axis tracking system is found to be 7 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The optimum configuration for two axis tracking system and two types of fixed tilt systems, is found to be a 8 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The results show that horizontal axis with

  20. Transient events in bright debris discs: Collisional avalanches revisited

    Science.gov (United States)

    Thebault, P.; Kral, Q.

    2018-01-01

    Context. A collisional avalanche is set off by the breakup of a large planetesimal, releasing vast amounts of small unbound grains that enter a debris disc located further away from the star, triggering there a collisional chain reaction that could potentially create detectable transient structures. Aims: We investigate this mechanism, using for the first time a fully self-consistent code coupling dynamical and collisional evolutions. We also quantify for the first time the photometric evolution of the system and investigate whether or not avalanches could explain the short-term luminosity variations recently observed in some extremely bright debris discs. Methods: We use the state-of-the-art LIDT-DD code. We consider an avalanche-favoring A6V star, and two set-ups: a "cold disc" case, with a dust release at 10 au and an outer disc extending from 50 to 120 au, and a "warm disc" case with the release at 1 au and a 5-12 au outer disc. We explore, in addition, two key parameters: the density (parameterized by its optical depth τ) of the main outer disc and the amount of dust released by the initial breakup. Results: We find that avalanches could leave detectable structures on resolved images, for both "cold" and "warm" disc cases, in discs with τ of a few 10-3, provided that large dust masses (≳1020-5 × 1022 g) are initially released. The integrated photometric excess due to an avalanche is relatively limited, less than 10% for these released dust masses, peaking in the λ 10-20 μm domain and becoming insignificant beyond 40-50 μm. Contrary to earlier studies, we do not obtain stronger avalanches when increasing τ to higher values. Likewise, we do not observe a significant luminosity deficit, as compared to the pre-avalanche level, after the passage of the avalanche. These two results concur to make avalanches an unlikely explanation for the sharp luminosity drops observed in some extremely bright debris discs. The ideal configuration for observing an

  1. Likelihood inference for unions of interacting discs

    DEFF Research Database (Denmark)

    Møller, Jesper; Helisova, K.

    2010-01-01

    This is probably the first paper which discusses likelihood inference for a random set using a germ-grain model, where the individual grains are unobservable, edge effects occur and other complications appear. We consider the case where the grains form a disc process modelled by a marked point...... process, where the germs are the centres and the marks are the associated radii of the discs. We propose to use a recent parametric class of interacting disc process models, where the minimal sufficient statistic depends on various geometric properties of the random set, and the density is specified......-based maximum likelihood inference and the effect of specifying different reference Poisson models....

  2. Tilt stability in nonlinear programming under Mangasarian-Fromovitz constraint qualification

    Czech Academy of Sciences Publication Activity Database

    Mordukhovich, B. S.; Outrata, Jiří

    2013-01-01

    Roč. 49, č. 3 (2013), s. 446-464 ISSN 0023-5954 R&D Projects: GA ČR(CZ) GAP201/12/0671 Institutional support: RVO:67985556 Keywords : variational analysis * second-order theory * generalized differentiation * tilt stability Subject RIV: BA - General Mathematics Impact factor: 0.563, year: 2013 http://library.utia.cas.cz/separaty/2013/MTR/outrata-tilt stability in nonlinear programming under mangasarian-fromovitz constraint qualification.pdf

  3. Posterior epidural disc fragment masquerading as spinal tumor: Review of the literature.

    Science.gov (United States)

    Park, Taejune; Lee, Ho Jun; Kim, Jae Seong; Nam, Kiyeun

    2018-03-09

    Posterior epidural lumbar disc fragment is infrequent because of anatomical barriers, and it is difficult to diagnose posterior epidural lumbar disc fragment because of its rare incidence and the ambiguity of radiologic evaluations. And it is difficult to differentiate it from other diseases such as spinal tumors. Differential diagnosis of posterior epidural lumbar disc fragment is clinically important because its diagnosis can affect treatment and prognosis. To investigate the incidence, anatomical concern, etiology, symptom, diagnostic tool, management and prognosis of posterior epidural lumbar disc fragment, we reviewed articles including case report. We performed a search of all clinical studies of posterior epidural lumbar disc fragment published to date. The following keywords were searched: Posterior epidural lumbar disc fragment, disc migration, posterior epidural disc, extradural migration, dorsal epidural migration, sequestrated disc, and disc fragment. We identified 40 patients of posterior epidural lumbar disc fragment from 28 studies. The most common presentation of posterior epidural lumbar disc fragment was sudden onset radiculopathy (70.0%), followed by cauda equina syndrome (27.5%). The most frequently used diagnostic modality was magnetic resonance imaging (MRI), conducted in 36 cases (90.0%), and followed by computed tomography in 14 cases (35.0%). After the imaging studies, the preoperative diagnoses were 45.0% masses, 20.0% lesions, and 12.5% tumors. Characteristic MRI findings in posterior epidural lumbar disc fragment are helpful for diagnosis; it typically displays low signals on T1-weighted images and high signals on T2-weighted images with respect to the parent disc. In addition, most of the disc fragments show peripheral rim enhancement on MRI with gadolinium administration. Electrodiagnostic testing is useful for verifying nerve damage. Surgical treatment was performed in all cases, and neurologic complications were observed in 12.5%. As

  4. Magnetic resonance imaging of diseased cervical and lumbar intervertebral discs

    Energy Technology Data Exchange (ETDEWEB)

    Kadoya, Satoru; Nakamura, Tsutomu; Takarada, Akira; Yamamoto, Itaru; Sato, Shuji.

    1989-02-01

    Magnetic resonance images (MRI) of diseased cervical and lumbar intervertebral discs involving both intrinsic and extrinsic cord lesions were examined using either a 0.15 T resistive or a 0.5 T superconductive magnetic imaging system. The vertebrae, intervertebral discs, and spinal cord were delineated on spin-echo (SE) images with a long repetition time (TR) and a short echo time (proton density-weighted image). Protrusion of degenerated intervertebral discs into the spinal canal was clearly demonstrated not only on sagittal but also on parasagittal and transverse views. The location of protruded discs and compression of the spinal cord, caudal sac, and nerve roots were well visualized three-dimensionally. Pathological features of intervertebral discs were well appreciated on T/sub 2/-weighted images with long TR and SE pulse sequences. Degeneration of intervertebral discs resulted in decreased signal intensity in cases of lumbar disc involvement. For suspected myelomalacia, the intrinsic cord lesion resulting from traumatic disc protrusion appeared as focal low signal intensity on T/sub 1/-weithed images and as somewhat high intensity on T/sub 2/ weighted images. The inversion recovery sequence with median inversion time displayed an inferior image of low contrast and was judged uninformative in comparison to SE imags. The findings showed MRI to be an essential diagnostic technique for spinal cord disorders. It clearly pinpoints the anatomic structures of the spine and the features of disc degeneration. Both extrinsic and intrinsic cord abnormalities can be identified with MRI. The selection of proper pulse sequences is required for the differentiation of the object of interest. (Namekawa, K).

  5. Magnetic resonance imaging of diseased cervical and lumbar intervertebral discs

    International Nuclear Information System (INIS)

    Kadoya, Satoru; Nakamura, Tsutomu; Takarada, Akira; Yamamoto, Itaru; Sato, Shuji.

    1989-01-01

    Magnetic resonance images (MRI) of diseased cervical and lumbar intervertebral discs involving both intrinsic and extrinsic cord lesions were examined using either a 0.15 T resistive or a 0.5 T superconductive magnetic imaging system. The vertebrae, intervertebral discs, and spinal cord were delineated on spin-echo (SE) images with a long repetition time (TR) and a short echo time (proton density-weighted image). Protrusion of degenerated intervertebral discs into the spinal canal was clearly demonstrated not only on sagittal but also on parasagittal and transverse views. The location of protruded discs and compression of the spinal cord, caudal sac, and nerve roots were well visualized three-dimensionally. Pathological features of intervertebral discs were well appreciated on T 2 -weighted images with long TR and SE pulse sequences. Degeneration of intervertebral discs resulted in decreased signal intensity in cases of lumbar disc involvement. For suspected myelomalacia, the intrinsic cord lesion resulting from traumatic disc protrusion appeared as focal low signal intensity on T 1 -weithed images and as somewhat high intensity on T 2 weighted images. The inversion recovery sequence with median inversion time displayed an inferior image of low contrast and was judged uninformative in comparison to SE imags. The findings showed MRI to be an essential diagnostic technique for spinal cord disorders. It clearly pinpoints the anatomic structures of the spine and the features of disc degeneration. Both extrinsic and intrinsic cord abnormalities can be identified with MRI. The selection of proper pulse sequences is required for the differentiation of the object of interest. (Namekawa, K)

  6. DISC1 (disrupted-in-schizophrenia-1 regulates differentiation of oligodendrocytes.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Hattori

    Full Text Available Disrupted-in-schizophrenia 1 (DISC1 is a gene disrupted by a translocation, t(1;11 (q42.1;q14.3, that segregates with major psychiatric disorders, including schizophrenia, recurrent major depression and bipolar affective disorder, in a Scottish family. Here we report that mammalian DISC1 endogenously expressed in oligodendroglial lineage cells negatively regulates differentiation of oligodendrocyte precursor cells into oligodendrocytes. DISC1 expression was detected in oligodendrocytes of the mouse corpus callosum at P14 and P70. DISC1 mRNA was expressed in primary cultured rat cortical oligodendrocyte precursor cells and decreased when oligodendrocyte precursor cells were induced to differentiate by PDGF deprivation. Immunocytochemical analysis showed that overexpressed DISC1 was localized in the cell bodies and processes of oligodendrocyte precursor cells and oligodendrocytes. We show that expression of the myelin related markers, CNPase and MBP, as well as the number of cells with a matured oligodendrocyte morphology, were decreased following full length DISC1 overexpression. Conversely, both expression of CNPase and the number of oligodendrocytes with a mature morphology were increased following knockdown of endogenous DISC1 by RNA interference. Overexpression of a truncated form of DISC1 also resulted in an increase in expression of myelin related proteins and the number of mature oligodendrocytes, potentially acting via a dominant negative mechanism. We also identified involvement of Sox10 and Nkx2.2 in the DISC1 regulatory pathway of oligodendrocyte differentiation, both well-known transcription factors involved in the regulation of myelin genes.

  7. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  8. Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting

    OpenAIRE

    Li, Lin; Wang, Ke; Yan, Yan; Song, Xudong; Liu, Zhicheng

    2013-01-01

    The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the anterior and posterior surfaces of the IOL. By the established relationship between IOL tilt (decentrati...

  9. Impaired perception of surface tilt in progressive supranuclear palsy.

    Directory of Open Access Journals (Sweden)

    Marian L Dale

    Full Text Available Progressive supranuclear palsy (PSP is characterized by early postural instability and backward falls. The mechanisms underlying backward postural instability in PSP are not understood. The aim of this study was to test the hypothesis that postural instability in PSP is a result of dysfunction in the perception of postural verticality.We gathered posturography data on 12 subjects with PSP to compare with 12 subjects with idiopathic Parkinson's Disease (PD and 12 healthy subjects. Objective tests of postural impairment included: dynamic sensory perception tests of gravity and of surface oscillations, postural responses to surface perturbations, the sensory organization test of postural sway under altered sensory conditions and limits of stability in stance.Perception of toes up (but not toes down surface tilt was reduced in subjects with PSP compared to both control subjects (p≤0.001 standing, p≤0.007 seated and subjects with PD (p≤0.03 standing, p≤0.04 seated. Subjects with PSP, PD and normal controls accurately perceived the direction of gravity when standing on a tilting surface. Unlike PD and control subjects, subjects with PSP exerted less postural corrective torque in response to toes up surface tilts.Difficulty perceiving backward tilt of the surface or body may account for backward falls and postural impairments in patients with PSP. These observations suggest that abnormal central integration of sensory inputs for perception of body and surface orientation contributes to the pathophysiology of postural instability in PSP.

  10. Jahn-Teller distortions, cation ordering and octahedral tilting in perovskites

    International Nuclear Information System (INIS)

    Lufaso, M.W.; Woodward, P.M.

    2004-01-01

    In transition metal oxides, preferential occupation of specific d orbitals on the transition metal ion can lead to the development of a long-range ordered pattern of occupied orbitals. This phenomenon, referred to as orbital ordering, is usually observed indirectly from the cooperative Jahn-Teller distortions (CJTDs) that result as a consequence of the orbital ordering. This paper examines the interplay between orbital ordering, octahedral tilting and cation ordering in perovskites. Both ternary AMX 3 perovskites containing an active Jahn-Teller (J-T) ion on the octahedral site and quaternary A 2 MM'X 6 perovskites containing a J-T ion on one-half of the octahedral sites have been examined. In AMX 3 perovskites, the tendency is for the occupied 3d 3x 2 -r 2 and 3d 3z 2 -r 2 orbitals to order in the ac plane, as exemplified by the crystal structures of LaMnO 3 and KCuF 3 . This arrangement maintains a favorable coordination environment for the anion sites. In AMX 3 perovskites, octahedral tilting tends to enhance the magnitude of the J-T distortions. In A 2 MM'X 6 perovskites, the tendency is for the occupied 3d 3z 2 -r 2 orbitals to align parallel to the c axis. This pattern maintains a favorable coordination environment about the symmetric M'-cation site. The orbital ordering found in rock-salt ordered A 2 MM'X 6 perovskites is compatible with octahedral rotations about the c axis (Glazer tilt system a 0 a 0 c - ) but appears to be incompatible with GdFeO 3 -type octahedral tilting (tilt system - b + a - ). (orig.)

  11. Protective effects of cannabidiol on lesion-induced intervertebral disc degeneration.

    Directory of Open Access Journals (Sweden)

    João W Silveira

    Full Text Available Disc degeneration is a multifactorial process that involves hypoxia, inflammation, neoinnervation, accelerated catabolism, and reduction in water and glycosaminoglycan content. Cannabidiol is the main non-psychotropic component of the Cannabis sativa with protective and anti-inflammatory properties. However, possible therapeutic effects of cannabidiol on intervertebral disc degeneration have not been investigated yet. The present study investigated the effects of cannabidiol intradiscal injection in the coccygeal intervertebral disc degeneration induced by the needle puncture model using magnetic resonance imaging (MRI and histological analyses. Disc injury was induced in the tail of male Wistar rats via a single needle puncture. The discs selected for injury were punctured percutaneously using a 21-gauge needle. MRI and histological evaluation were employed to assess the results. The effects of intradiscal injection of cannabidiol (30, 60 or 120 nmol injected immediately after lesion were analyzed acutely (2 days by MRI. The experimental group that received cannabidiol 120 nmol was resubmitted to MRI examination and then to histological analyses 15 days after lesion/cannabidiol injection. The needle puncture produced a significant disc injury detected both by MRI and histological analyses. Cannabidiol significantly attenuated the effects of disc injury induced by the needle puncture. Considering that cannabidiol presents an extremely safe profile and is currently being used clinically, these results suggest that this compound could be useful in the treatment of intervertebral disc degeneration.

  12. Feature Based Control of Compact Disc Players

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh

    Two servo control loops are used to keep the Optical Pick-up Unit focused and radially on the information track of the Compact Disc. These control servos have problems handling surface faults on the Compact Disc. In this Ph.D thesis a method is proposed to improve the handling of these surface...

  13. Analysis of a ferrofluid core differential transformer tilt measurement sensor

    Energy Technology Data Exchange (ETDEWEB)

    Medvegy, T.; Molnár, Á.; Molnár, G.; Gugolya, Z.

    2017-04-15

    In our work, we developed a ferrofluid core differential transformer sensor, which can be used to measure tilt and acceleration. The proposed sensor consisted of three coils, from which the primary was excited with an alternating current. In the space surrounded by the coils was a cell half-filled with ferrofluid, therefore in the horizontal state of the sensor the fluid distributes equally in the three sections of the cell surrounded by the three coils. Nevertheless when the cell is being tilted or accelerated (in the direction of the axis of the coils), there is a different amount of ferrofluid in the three sections. The voltage induced in the secondary coils strongly depends on the amount of ferrofluid found in the core surrounded by them, so the tilt or the acceleration of the cell becomes measurable. We constructed the sensor in several layouts. The linearly coiled sensor had an excellent resolution. Another version with a toroidal cell had almost perfect linearity and a virtually infinite measuring range. - Highlights: • A ferrofluid core differential transformer can be used to measure tilt. • The theoretical description of two different type of the sensor is introduced. • The measuring range, and the sensitivity depends on the dimensions of the sensor.

  14. Super-Cavitating Flow Around Two-Dimensional Conical, Spherical, Disc and Stepped Disc Cavitators

    Science.gov (United States)

    Sooraj, S.; Chandrasekharan, Vaishakh; Robson, Rony S.; Bhanu Prakash, S.

    2017-08-01

    A super-cavitating object is a high speed submerged object that is designed to initiate a cavitation bubble at the nose which extends past the aft end of the object, substantially reducing the skin friction drag that would be present if the sides of the object were in contact with the liquid in which the object is submerged. By reducing the drag force the thermal energy consumption to move faster can also be minimised. The super-cavitation behavioural changes with respect to Cavitators of various geometries have been studied by varying the inlet velocity. Two-dimensional computational fluid dynamics analysis has been carried out by applying k-ε turbulence model. The variation of drag coefficient, cavity length with respect to cavitation number and inlet velocity are analyzed. Results showed conical Cavitator with wedge angle of 30° has lesser drag coefficient and cavity length when compared to conical Cavitators with wedge angles 45° and 60°, spherical, disc and stepped disc Cavitators. Conical cavitator 60° and disc cavitator have the maximum cavity length but with higher drag coefficient. Also there is significant variation of supercavitation effect observed between inlet velocities of 32 m/s to 40 m/s.

  15. The effects of diode laser on Staphylococcus aureus biofilm and Escherichia coli lipopolysaccharide adherent to titanium oxide surface of dental implants. An in vitro study.

    Science.gov (United States)

    Giannelli, Marco; Landini, Giulia; Materassi, Fabrizio; Chellini, Flaminia; Antonelli, Alberto; Tani, Alessia; Zecchi-Orlandini, Sandra; Rossolini, Gian Maria; Bani, Daniele

    2016-11-01

    Effective decontamination of biofilm and bacterial toxins from the surface of dental implants is a yet unresolved issue. This in vitro study aims at providing the experimental basis for possible use of diode laser (λ 808 nm) in the treatment of peri-implantitis. Staphylococcus aureus biofilm was grown for 48 h on titanium discs with porous surface corresponding to the bone-implant interface and then irradiated with a diode laser (λ 808 nm) in noncontact mode with airflow cooling for 1 min using a Ø 600-μm fiber. Setting parameters were 2 W (400 J/cm 2 ) for continuous wave mode; 22 μJ, 20 kHz, 7 μs (88 J/cm 2 ) for pulsed wave mode. Bactericidal effect was evaluated using fluorescence microscopy and counting the residual colony-forming units. Biofilm and titanium surface morphology were analyzed by scanning electron microscopy (SEM). In parallel experiments, the titanium discs were coated with Escherichia coli lipopolysaccharide (LPS), laser-irradiated and seeded with RAW 264.7 macrophages to quantify LPS-driven inflammatory cell activation by measuring the enhanced generation of nitric oxide (NO). Diode laser irradiation in both continuous and pulsed modes induced a statistically significant reduction of viable bacteria and nitrite levels. These results indicate that in addition to its bactericidal effect laser irradiation can also inhibit LPS-induced macrophage activation and thus blunt the inflammatory response. The λ 808-nm diode laser emerges as a valuable tool for decontamination/detoxification of the titanium implant surface and may be used in the treatment of peri-implantitis.

  16. Tilted Bianchi type I dust fluid cosmological model in general relativity

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 58; Issue 3. Tilted Bianchi type I dust fluid cosmological model in general ... In this paper, we have investigated a tilted Bianchi type I cosmological model filled with dust of perfect fluid in general relativity. To get a determinate solution, we have assumed a condition  ...

  17. Disc displacement patterns in lumbar anterior spondylolisthesis: Contribution to foraminal stenosis

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Taylor, D.H.; Duke, D.; Brennan, D.D.; Eustace, S.J.

    2009-01-01

    Purpose: To describe the particular disc displacement pattern seen at MRI in patients with spondylolisthesis, and its potential contribution to foraminal stenosis. Methods: 38 patients with symptomatic lumbar anterior spondylolisthesis and 38 sex and aged matched control patients with herniated disc disease, at corresponding disc space levels, were included for study. In each case note was made of the presence, absence and direction of disc displacement and also the presence and location of neural contact with the displaced disc. Results: In 33 of 38 (86.8%) patients in the spondylolisthesis group, the vertical disc displacement was upward. In the control group only 3 patients (7.8%) had upward vertical disc displacement. 19 patients (53%) from the spondylolisthesis group had exit foraminal nerve root contact, compared to 7 patients (18.4%) from the control group. 27 control patients (71%) had contact within the lateral recess, compared to only 6 patients (17%) with spondylolisthesis. Differences for upward displacement were significant (p < 0.05). Conclusion: Disc displacement in patients with spondylolisthesis is predominately in a cephalad and lateral direction. Although this disc displacement pattern can occur in patients without spondylolisthesis, its incidence is much greater in the subset of patients with concomitant spondylolisthesis. In the setting of acquired osseous narrowing of the exit foramen, this described pattern of disc displacement superiorly and laterally in spondylolisthesis increases the susceptibility of spondylolisthesis patients to radicular symptoms and accounts for the exiting nerve root being more commonly affected than the traversing nerve root.

  18. A tilted transversely isotropic slowness surface approximation

    KAUST Repository

    Stovas, A.

    2012-05-09

    The relation between vertical and horizontal slownesses, better known as the dispersion relation, for transversely isotropic media with a tilted symmetry axis (TTI) requires solving a quartic polynomial equation, which does not admit a practical explicit solution to be used, for example, in downward continuation. Using a combination of the perturbation theory with respect to the anelliptic parameter and Shanks transform to improve the accuracy of the expansion, we develop an explicit formula for the vertical slowness that is highly accurate for all practical purposes. It also reveals some insights into the anisotropy parameter dependency of the dispersion relation including the low impact that the anelliptic parameter has on the vertical placement of reflectors for a small tilt in the symmetry angle. © 2012 European Association of Geoscientists & Engineers.

  19. Documentation of programs that compute 1) static tilts for a spatially variable slip distribution, and 2) quasi-static tilts produced by an expanding dislocation loop with a spatially variable slip distribution

    Science.gov (United States)

    McHugh, Stuart

    1976-01-01

    The material in this report is concerned with the effects of a vertically oriented rectangular dislocation loop on the tilts observed at the free surface of an elastic half-space. Part I examines the effect of a spatially variable static strike-slip distribution across the slip surface. The tilt components as a function of distance parallel, or perpendicular, to the strike of the slip surface are displayed for different slip-versus-distance profiles. Part II examines the effect of spatially and temporally variable slip distributions across the dislocation loop on the quasi-static tilts at the free surface of an elastic half space. The model discussed in part II may be used to generate theoretical tilt versus time curves produced by creep events.

  20. Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

    Science.gov (United States)

    Clement, Gilles; Wood, Scott J.

    2010-01-01

    This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

  1. Effect of manual tilt adjustments on incident irradiance on fixed and tracking solar panels

    International Nuclear Information System (INIS)

    Lubitz, William David

    2011-01-01

    Hourly typical meteorological year (TMY3) data was utilized with the Perez radiation model to simulate solar radiation on fixed, azimuth tracking and two axis tracking surfaces at 217 geographically diverse temperate latitude sites across the contiguous United States of America. The optimum tilt angle for maximizing annual irradiation on a fixed south-facing panel varied from being equal to the latitude at low-latitude, high clearness sites, to up to 14 o less than the latitude at a north-western coastal site with very low clearness index. Across the United States, the optimum tilt angle for an azimuth tracking panel was found to be on average 19 o closer to vertical than the optimum tilt angle for a fixed, south-facing panel at the same site. Azimuth tracking increased annual solar irradiation incident on a surface by an average of 29% relative to a fixed south-facing surface at optimum tilt angle. Two axis tracking resulted in an average irradiation increase of 34% relative to the fixed surface. Introduction of manual surface tilt changes during the year produced a greater impact for non-tracking surfaces than it did for azimuth tracking surfaces. Even monthly tilt changes only resulted in an average annual irradiation increase of 5% for fixed panels and 1% for azimuth tracked surfaces, relative to using a single optimized tilt angle in each case. In practice, the decision whether to manually tilt panels requires balancing the added cost in labor and the panel support versus the extra energy generation and the cost value of that energy. A spreadsheet file is available that gives individual results for each of the 217 simulated sites.

  2. A method for quantitative measurement of lumbar intervertebral disc structures

    DEFF Research Database (Denmark)

    Tunset, Andreas; Kjær, Per; Samir Chreiteh, Shadi

    2013-01-01

    There is a shortage of agreement studies relevant for measuring changes over time in lumbar intervertebral disc structures. The objectives of this study were: 1) to develop a method for measurement of intervertebral disc height, anterior and posterior disc material and dural sac diameter using MR...

  3. Estimation of pelvic tilt on anteroposterior X-rays - a comparison of six parameters

    International Nuclear Information System (INIS)

    Tannast, M.; Murphy, S.B.; Langlotz, F.; Anderson, S.E.; Siebenrock, K.A.

    2006-01-01

    To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum. (orig.)

  4. Tilt shift determinations with spatial-carrier phase-shift method in temporal phase-shift interferometry

    International Nuclear Information System (INIS)

    Liu, Qian; Wang, Yang; He, Jianguo; Ji, Fang; Wang, Baorui

    2014-01-01

    An algorithm is proposed to deal with tilt-shift errors in temporal phase-shift interferometry (PSI). In the algorithm, the tilt shifts are detected with the spatial-carrier phase-shift (SCPS) method and then the tilt shifts are applied as priori information to the least-squares fittings of phase retrieval. The algorithm combines the best features of the SCPS and the temporal PSI. The algorithm could be applied to interferograms of arbitrary aperture without data extrapolation for the Fourier transform is not involved. Simulations and experiments demonstrate the effectiveness of the algorithm. The statistics of simulation results show a satisfied accuracy in detecting tilt-shift errors. Comparisons of the measurements with and without environmental vibration show that the proposed algorithm could compensate tilt-shift errors and retrieve wavefront phase accurately. The algorithm provides an approach to retrieve wavefront phase for the temporal PSI in vibrating environment. (paper)

  5. Tilt rotor tricopter : control system for the holonomic multirotor platform

    OpenAIRE

    Gjertsen, Sindre; Salem, Daniel

    2013-01-01

    Masteroppgave i mekatronikk MAS500 2013 – Universitetet i Agder, Grimstad Development of a new approach to the multicopter segment of the Unmanned Areal Vehicle (UAV) family is presented. The system is designed on a T-shaped tricopter platform with ability to tilt all three motors, hereby defined as Tilt Rotor Tricopter (TRT). The highly coupled nonlinear system is investigated through the mathematical model, and verified by simulations. Linearization of the system has been ach...

  6. Outcome of Cloward technique in cervical disc prolapse.

    Science.gov (United States)

    Rehman, Lal; Qayoom Khan, Hina Abdul; Hashim, A Sattar M

    2010-11-01

    To determine the association of pre-operative assessment of MRI findings, neurological status and symptoms with postoperative Cloward surgical outcome in cervical disc prolapse. Descriptive study. The Neurosurgery Department of Jinnah Postgraduate Medical Centre (JPMC), Karachi, from May 2008 to May 2009. Patients presenting with neck pain, brachialgia, limb weakness and spasticity were clinically examined for pre-operative neurological status of power, reflexes and sensation. The exclusion criteria were, cervical disc prolapsed patients, planned for smith-Robinson and micro-discectomy, traumatic cervical disc prolapse and cervical spondylosis. Neuroradiological investigations included cervical spine X-rays and MRI. All patients were surgically treated for cervical prolapsed intervertebral disc with anterior cervical discectomy and interbody fusion with Cloward technique. Postoperative neck immobilization was done with cervical collar for 7-8 weeks. Drain was removed on first postoperative day while check plain cervical X-rays were taken on third day. Results were analysed using chi-square test with significance at p cervical disc prolapse were C 5-6 (43.3%) and C 6-7 (23.3%); 26 (86.6%) patients had disc herniation causing thecal effacement with cord compression and 04 (13.3%) patients showed ischemia of cord. Single-level Cloward surgery done in 26 (86.3%) patients while two-level Cloward surgery performed in 04 (13.3%) only. About 83.3% patients improved and 13.3% did not while 01 patient was re-operated. No complications and mortality was related to the surgical procedure. Statistically different variables identified, related to outcome were pre-operative neurological status (p=0.001) and spinal cord involvement on MRI (p=0.001). Cloward technique for cervical disc prolase was simple and safe surgical procedure with favourable results and few complications; 100% fusion occurred after Cloward surgery, even without instrumentation. Outcome was significantly

  7. Low virulence bacterial infections in cervical intervertebral discs: a prospective case series.

    Science.gov (United States)

    Chen, Yilei; Wang, Xianjun; Zhang, Xuyang; Ren, Hong; Huang, Bao; Chen, Jian; Liu, Junhui; Shan, Zhi; Zhu, Zhihai; Zhao, Fengdong

    2018-04-19

    A prospective cross-sectional case series study. To investigate the prevalence of low virulence disc infection and its associations with characteristics of patients or discs in the cervical spine. Low virulence bacterial infections could be a possible cause of intervertebral disc degeneration and/or back pain. Controversies are continuing over whether these bacteria, predominantly Propionibacterium acnes (P. acnes), represent infection or contamination. However, the current studies mainly focus on the lumbar spine, with very limited data on the cervical spine. Thirty-two patients (20 men and 12 women) who underwent anterior cervical fusion for degenerative cervical spondylosis or traumatic cervical cord injury were enrolled. Radiological assessments included X-ray, CT, and MRI of the cervical spine. Endplate Modic changes, intervertebral range of motion, and disc herniation type were evaluated. Disc and muscle tissues were collected under strict sterile conditions. Samples were enriched in tryptone soy broth and subcultured under anaerobic conditions, followed by identification of the resulting colonies by the PCR method. Sixty-six intervertebral discs were excised from thirty-two patients. Positive disc cultures were noted in eight patients (25%) and in nine discs (13.6%). The muscle biopsy (control) cultures were negative in 28 patients and positive in 4 patients (12.5%); three of whom had a negative disc culture. Seven discs (10.6%) were positive for coagulase-negative Staphylococci (CNS) and two discs were positive for P. acnes (3.0%). A younger patient age and the extrusion or sequestration type of disc herniation, which represented a complete annulus fibrous failure, were associated with positive disc culture. Our data show that CNS is more prevalent than P. acnes in degenerative cervical discs. The infection route in cervical discs may be predominantly through an annulus fissure. Correlation between these infections and clinical symptoms is uncertain

  8. An affine model of the dynamics of astrophysical discs

    Science.gov (United States)

    Ogilvie, Gordon I.

    2018-06-01

    Thin astrophysical discs are very often modelled using the equations of 2D hydrodynamics. We derive an extension of this model that describes more accurately the behaviour of a thin disc in the absence of self-gravity, magnetic fields, and complex internal motions. The ideal fluid theory is derived directly from Hamilton's Principle for a 3D fluid after making a specific approximation to the deformation gradient tensor. We express the equations in Eulerian form after projection on to a reference plane. The disc is thought of as a set of fluid columns, each of which is capable of a time-dependent affine transformation, consisting of a translation together with a linear transformation in three dimensions. Therefore, in addition to the usual 2D hydrodynamics in the reference plane, the theory allows for a deformation of the mid-plane (as occurs in warped discs) and for the internal shearing motions that accompany such deformations. It also allows for the vertical expansions driven in non-circular discs by a variation of the vertical gravitational field around the horizontal streamlines, or by a divergence of the horizontal velocity. The equations of the affine model embody conservation laws for energy and potential vorticity, even for non-planar discs. We verify that they reproduce exactly the linear theories of 3D warped and eccentric discs in a secular approximation. However, the affine model does not rely on any secular or small-amplitude assumptions and should be useful in more general circumstances.

  9. Wear studies on ZrO2-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V

    International Nuclear Information System (INIS)

    Song, Jian; Liu, Yuhong; Liao, Zhenhua; Wang, Song; Tyagi, Rajnesh; Liu, Weiqiang

    2016-01-01

    Polyetheretherketone (PEEK) and its composite coatings are believed to be the potential candidates' bio-implant materials. However, these coatings have not yet been used on the surface of titanium-based orthopedics and joint products and very few investigations on the tribological characteristics could be found in the published literature till date. In this study, the wettabilities, composition and micro-hardness were characterized using contact angle measurement, scanning electron microscopy (SEM) and hardness tester. The tribological tests were conducted using a ball-on-disc contact pair under 25% newborn calf serum (NCS) lubricated condition. For comparison, bare Ti6Al4V was studied. The obtained results revealed that those PEEK/ZrO 2 composite coatings could improve the tribological properties of Ti6Al4V significantly. Adhesive wear and mild abrasive wear might be the dominant wear and failure mechanisms for PEEK/ZrO 2 composite coatings in NCS lubricated condition. After comprehensive evaluation in the present study, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Graphical abstract: Polyetheretherketone (PEEK) is a type of biomaterial which might be used in surface modification. In this study, the wettabilities, composition, hardness, friction and wear characteristics of PEEK/ZrO 2 coatings were investigated, compared with bare Ti6Al4V sample. After comprehensive evaluation, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Highlights: • PEEK coating were filled by ZrO 2 nanoparticles with different weight percentage. • The lubrication regime of all the tested samples are boundary lubrication. • Adhesive wear and mild abrasive wear were the dominant wear

  10. Novel localized heating technique on centrifugal microfluidic disc with wireless temperature monitoring system.

    Science.gov (United States)

    Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman

    2015-01-01

    Recent advances in the field of centrifugal microfluidic disc suggest the need for electrical interface in the disc to perform active biomedical assays. In this paper, we have demonstrated an active application powered by the energy harvested from the rotation of the centrifugal microfluidic disc. A novel integration of power harvester disc onto centrifugal microfluidic disc to perform localized heating technique is the main idea of our paper. The power harvester disc utilizing electromagnetic induction mechanism generates electrical energy from the rotation of the disc. This contributes to the heat generation by the embedded heater on the localized heating disc. The main characteristic observed in our experiment is the heating pattern in relative to the rotation of the disc. The heating pattern is monitored wirelessly with a digital temperature sensing system also embedded on the disc. Maximum temperature achieved is 82 °C at rotational speed of 2000 RPM. The technique proves to be effective for continuous heating without the need to stop the centrifugal motion of the disc.

  11. Lateral forces exerted through ball or bar attachments in relation to the inclination of mini-implant underneath overdentures: in vitro study.

    Science.gov (United States)

    Takagaki, Kyozo; Gonda, Tomoya; Maeda, Yoshinobu

    2015-09-01

    Lateral force to mini-implants should be avoided because mini-implants are weak mechanically because of its small diameter. Overdentures retained by mini-implants are usually formed using ball attachments. However, bar attachments can offer the advantage of splinting the mini-implants. This study examined the effect of attachments in withstanding these lateral forces in tilted mini-implants of overdentures. Strain gauges were attached to the mini-implants (2.5 × 18 mm) embedded in an acrylic resin block. Two mini-implants were inserted vertically (Control) or with one mini-implant inclined at 10° or 20° (10-inclined and 20-inclined, respectively). The female portions of the attachments were secured to the denture base. A prefabricated ball attachment and CAD/CAM-fabricated bar attachment were compared. A vertical load of 49 N was applied to the occlusal surface at a distance 10 mm away from the center of two mini-implants. The lateral force borne by the mini-implants was measured via the attached strain gauge. Mann-Whitney U-test and an analysis of Bonferroni correction were used to compare differences between the two attachments and among the three models (P < 0.05). The lateral force exerted to the inclined mini-implant was significantly greater than that borne by a vertical mini-implant for both attachment types. The lateral force on the 20° inclined mini-implants with bar attachments was smaller than that on mini-implants with ball attachments. Inclined mini-implants are subjected to greater stresses than vertical ones, and a bar attachment can reduce the lateral forces borne by the mini-implant when one mini-implant inclined at 20°. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Nonlinear fluid/structure interaction relating a rupture-disc pressure-relief device

    International Nuclear Information System (INIS)

    Hsieh, B.J.; Kot, C.A.; Shin, Y.W.; Youngdahl, C.K.

    1983-01-01

    Rupture disc assemblies are used in piping network systems as a pressure-relief device. The reverse-buckling type is chosen for application in a liquid metal fast breeder reactor. This assembly is used successfully in systems in which the fluid is highly compressible, such as air; the opening up of the disc by the knife setup is complete. However, this is not true for a liquid system; it had been observed experimentally that the disc may open up only partially or not at all. Therefore, to realistically understand and represent a rupture disc assembly in a liquid environment, the fluid-structure interactions between the liquid medium and the disc assembly must be considered. The methods for analyzing the fluid and the disc and the mechanism interconnecting them are presented. The fluid is allowed to cavitate through a column-cavitation model and the disc is allowed to become plastically deformed through the classic Von Mises' yield criteria, when necessary

  13. Acupuncture and Spontaneous Regression of a Radiculopathic Cervical Herniated Disc

    Directory of Open Access Journals (Sweden)

    Kim Sung-Ha

    2012-06-01

    Full Text Available The spontaneous regression of herniated cervical discs is not a well-established phenomenon. However, we encountered a case of a spontaneous regression of a severe radiculopathic herniated cervical disc that was treated with acupuncture, pharmacopuncture, and herb medicine. The symptoms were improved within 12 months of treatment. Magnetic resonance imaging (MRI conducted at that time revealed marked regression of the herniated disc. This case provides an additional example of spontaneous regression of a herniated cervical disc documented by MRI following non-surgical treatment.

  14. Influence of tilt training on activation of the autonomic nervous system in patients with vasovagal syncope.

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Halawa, Bogumił; Mazurek, Walentyna

    2006-04-01

    Tilt training is a new treatment for vasovagal syncope. Its therapeutic efficacy is thought to be the result of the desensitization of cardiopulmonary receptors, but it could be the influence of the tilt training on the activation of the autonomic nervous system as well. The study group consisted of 24 vasovagal patients (17 women and 7 men) aged 32.5 +/- 11.8 years. The diagnostic head-up tilt test was performed according to the Italian protocol with nitroglycerin if necessary. The monitoring head-up tilt test was performed according to the Westminster protocol without provocation, after 1 to 3 months of tilt training. Holter ECG recordings for HRV parameters (time and frequency domain) were obtained from selected 2-min intervals before, during and after the diagnostic and monitoring tilt test. The diagnostic test was positive in the passive phase in 6 and after provocation in 18 patients. During the training period no syncope occurred. Analysing the HRV parameters we demonstrated the following findings: I. mRR decreases immediately after assumption of a vertical position in both tests (diagnostic and monitoring) but in the diagnostic test its further decrease occurs earlier than in the monitoring test; 2. the absolute power of the HF component is greater in the early phase of tilt after tilt training than in the corresponding period in the diagnostic test. After a longer period of tilt training the activation of the sympathetic nervous system in response to the erect position is diminished.

  15. Vertebral osteomyelitis without disc involvement

    Energy Technology Data Exchange (ETDEWEB)

    Kamani, I.; Syed, I.; Saifuddin, A. E-mail: asaifuddin@aol.com; Green, R.; MacSweeney, F

    2004-10-01

    Vertebral osteomyelitis is most commonly due to pyogenic or granulomatous infection and typically results in the combined involvement of the intervertebral disc and adjacent vertebral bodies. Non-infective causes include the related conditions of chronic recurrent multifocal osteomyelitis (CRMO) and SAPHO (synovitis, acne, pustulosis, hyperostosis, and osteitis) syndrome. Occasionally, these conditions may present purely within the vertebral body, resulting in various combinations of vertebral marrow oedema and sclerosis, destructive lesions of the vertebral body and pathological vertebral collapse, thus mimicking neoplastic disease. This review illustrates the imaging features of vertebral osteomyelitis without disc involvement, with emphasis on magnetic resonance imaging (MRI) findings.

  16. Changes seen on magnetic resonance imaging in the intervertebral disc space after chemonucleosis: a hypothesis concerning regeneration of the disc after chemonucleosis

    International Nuclear Information System (INIS)

    Kato, F.; Mimatsu, K.; Kawakami, N.; Miura, T.

    1992-01-01

    Measurements of the intervertebral disc space were made by magnetic resonance imaging and plain film examinations over a period of 2 years in 26 patients who had undergone chemonucleolysis. The height of the posterior portion of the disc decreased after 3 months and never recovered; the height of the anterior portion also decreased but recovered slightly over the same period. The angle of lordosis and the range of motion in the treated segment were decreased, but recovered. Marked decrease in signal from the disc was observed after 2 weeks which did not recover till 2 years after chemonucleolysis. We suspect that the disc degenerated markedly after chemonucleolysis and changed into a type of scar tissue, maturation of which could stabilize the affected segment. (orig.)

  17. Changes seen on magnetic resonance imaging in the intervertebral disc space after chemonucleosis: a hypothesis concerning regeneration of the disc after chemonucleosis

    Energy Technology Data Exchange (ETDEWEB)

    Kato, F; Mimatsu, K; Kawakami, N; Miura, T [Dept. of Orthopaedic Surgery, School of Medicine, Nagoya Univ. (Japan)

    1992-08-01

    Measurements of the intervertebral disc space were made by magnetic resonance imaging and plain film examinations over a period of 2 years in 26 patients who had undergone chemonucleolysis. The height of the posterior portion of the disc decreased after 3 months and never recovered; the height of the anterior portion also decreased but recovered slightly over the same period. The angle of lordosis and the range of motion in the treated segment were decreased, but recovered. Marked decrease in signal from the disc was observed after 2 weeks which did not recover till 2 years after chemonucleolysis. We suspect that the disc degenerated markedly after chemonucleolysis and changed into a type of scar tissue, maturation of which could stabilize the affected segment. (orig.).

  18. Comparative analysis of diffused solar radiation models for optimum tilt angle determination for Indian locations

    International Nuclear Information System (INIS)

    Yadav, P.; Chandel, S.S.

    2014-01-01

    Tilt angle and orientation greatly are influenced on the performance of the solar photo voltaic panels. The tilt angle of solar photovoltaic panels is one of the important parameters for the optimum sizing of solar photovoltaic systems. This paper analyses six different isotropic and anisotropic diffused solar radiation models for optimum tilt angle determination. The predicted optimum tilt angles are compared with the experimentally measured values for summer season under outdoor conditions. The Liu and Jordan model is found to exhibit t lowest error as compared to other models for the location. (author)

  19. Oxygen depth profiling in Kr+-implanted polycrystalline alpha titanium by means of 16O(α,α)16O resonance scattering

    International Nuclear Information System (INIS)

    Nsengiyumva, S.; Riviere, J.P.; Raji, A.T.; Comrie, C.M.; Britton, D.T.; Haerting, M.

    2011-01-01

    The 16 O(α,α) 16 O resonance scattering was applied to study the effects of ion implantation on the oxygen distribution in the near surface region of polycrystalline titanium implanted with 180 keV krypton ions at fluences, ranging between 1 x 10 14 and 5 x 10 15 Kr + /cm 2 . Two sample sets were chosen: as-received polycrystalline titanium discs rolled and annealed in half-hard condition which had a thick oxygen layer and similar samples in which this surface layer was removed by polishing. An increase of the mean oxygen concentration observed in both unpolished and polished samples at low fluence suggests a knock-on implantation of surface oxygen atoms. At high fluence, an overall decrease in the mean oxygen concentration and mean oxygen depth suggests an out-diffusion of near-surface oxygen atoms.

  20. Tilting Uranus without a Collision

    Science.gov (United States)

    Rogoszinski, Zeeve; Hamilton, Douglas P.

    2016-10-01

    The most accepted hypothesis for the origin of Uranus' 98° obliquity is a giant collision during the late stages of planetary accretion. This model requires a single Earth mass object striking Uranus at high latitudes; such events occur with a probability of about 10%. Alternatively, Uranus' obliquity may have arisen from a sequence of smaller impactors which lead to a uniform distribution of obliquities. Here we explore a third model for tilting Uranus using secular spin-orbit resonance theory. We investigate early Solar System configurations in which a secular resonance between Uranus' axial precession frequency and another planet's orbital node precession frequency might occur.Thommes et al. (1999) hypothesized that Uranus and Neptune initially formed between Jupiter and Saturn, and were then kicked outward. In our scenario, Neptune leaves first while Uranus remains behind. As an exterior Neptune slowly migrates outward, it picks up both Uranus and Saturn in spin-orbit resonances (Ward and Hamilton 2004; Hamilton and Ward 2004). Only a distant Neptune has a nodal frequency slow enough to resonate with Uranus' axial precession.This scenario, with diverging orbits, results in resonance capture. As Neptune migrates outward its nodal precession slows. While in resonance, Uranus and Saturn each tilt a bit further, slowing their axial precession rates to continually match Neptune's nodal precession rate. Tilting Uranus to high obliquities takes a few 100 Myrs. This timescale may be too long to hold Uranus captive between Jupiter and Saturn, and we are investigating how to reduce it. We also find that resonance capture is rare if Uranus' initial obliquity is greater than about 10°, as the probability of capture decreases as the planet's initial obliquity increases. We will refine this estimate by quantifying capture statistics, and running accretion simulations to test the likelihood of a low early obliquity. Our preliminary findings show that most assumptions about