WorldWideScience

Sample records for implanted intrathecal drug

  1. Measured density and calculated baricity of custom-compounded drugs for chronic intrathecal infusion.

    Science.gov (United States)

    Hejtmanek, Michael R; Harvey, Tracy D; Bernards, Christopher M

    2011-01-01

    To minimize the frequency that intrathecal pumps require refilling, drugs are custom compounded at very high concentrations. Unfortunately, the baricity of these custom solutions is unknown, which is problematic, given baricity's importance in determining the spread of intrathecally administered drugs. Consequently, we measured the density and calculated the baricity of clinically relevant concentrations of multiple drugs used for intrathecal infusion. Morphine, clonidine, bupivacaine, and baclofen were weighed to within 0.0001 g and diluted in volumetric flasks to produce solutions of known concentrations (morphine 1, 10, 25, and 50 mg/mL; clonidine 0.05, 0.5, 1, and 3 mg/mL; bupivacaine 2.5, 5, 10, and 20 mg/mL; baclofen 1, 1.5, 2, and 4 mg/mL). The densities of the solutions were measured at 37°C using the mechanical oscillation method. A "best-fit" curve was calculated for plots of concentration versus density for each drug. All prepared solutions of clonidine and baclofen were hypobaric. Higher concentrations of morphine and bupivacaine were hyperbaric, whereas lower concentrations were hypobaric. The relationship between concentration and density is linear for morphine (r > 0.99) and bupivacaine (r > 0.99) and logarithmic for baclofen (r = 0.96) and clonidine (r = 0.98). This is the first study to examine the relationship between concentration and density for custom drug concentrations commonly used in implanted intrathecal pumps. We calculated an equation that defines the relationship between concentration and density for each drug. Using these equations, clinicians can calculate the density of any solution made from the drugs studied here.

  2. Intrathecal Catheterization and Drug Delivery in Guinea Pigs: A Small-animal Model for Morphine-evoked Granuloma Formation.

    Science.gov (United States)

    Eddinger, Kelly A; Rondon, Eric S; Shubayev, Veronica I; Grafe, Marjorie R; Scadeng, Miriam; Hildebrand, Keith R; Page, Linda M; Malkmus, Shelle A; Steinauer, Joanne J; Yaksh, Tony L

    2016-08-01

    Intrathecal infusion of opioids in dogs, sheep, and humans produces local space-occupying masses. To develop a small-animal model, the authors examined effects of intrathecal catheterization and morphine infusion in guinea pigs. Under isoflurane, polyethylene or polyurethane catheters were advanced from the cisterna magna to the lumbar enlargement. Drugs were delivered as a bolus through the externalized catheter or continuously by subcutaneous minipumps. Hind paw withdrawal to a thermal stimulus was assessed. Spinal histopathology was systematically assessed in a blinded fashion. To assist in determining catheter placement, ex vivo images were obtained using magnetic resonance imaging in several animals. Canine spinal tissue from previous intrathecal morphine studies was analyzed in parallel. (1) Polyethylene (n = 30) and polyurethane (n = 25) catheters were implanted in the lumbar intrathecal space. (2) Bolus intrathecal morphine produced a dose-dependent (20 to 40 μg/10 μl) increase in thermal escape latencies. (3) Absent infusion, a catheter-associated distortion of the spinal cord and a fibrotic investment were noted along the catheter tract (polyethylene > polyurethane). (4) Intrathecal morphine infusion (25 mg/ml/0.5 μl/h for 14 days) resulted in intrathecal masses (fibroblasts, interspersed collagen, lymphocytes, and macrophages) arising from meninges proximal to the catheter tip in both polyethylene- and polyurethane-catheterized animals. This closely resembles mass histopathology from intrathecal morphine canine studies. Continuous intrathecal infusion of morphine leads to pericatheter masses that morphologically resemble those observed in dogs and humans. This small-animal model may be useful for studying spinal drug toxicology in general and the biology of intrathecal granuloma formation in particular.

  3. Continuous intrathecal orexin delivery inhibits cataplexy in a murine model of narcolepsy.

    Science.gov (United States)

    Kaushik, Mahesh K; Aritake, Kosuke; Imanishi, Aya; Kanbayashi, Takashi; Ichikawa, Tadashi; Shimizu, Tetsuo; Urade, Yoshihiro; Yanagisawa, Masashi

    2018-06-05

    Narcolepsy-cataplexy is a chronic neurological disorder caused by loss of orexin (hypocretin)-producing neurons, associated with excessive daytime sleepiness, sleep attacks, cataplexy, sleep paralysis, hypnagogic hallucinations, and fragmentation of nighttime sleep. Currently, human narcolepsy is treated by providing symptomatic therapies, which can be associated with an array of side effects. Although peripherally administered orexin does not efficiently penetrate the blood-brain barrier, centrally delivered orexin can effectively alleviate narcoleptic symptoms in animal models. Chronic intrathecal drug infusion through an implantable pump is a clinically available strategy to treat a number of neurological diseases. Here we demonstrate that the narcoleptic symptoms of orexin knockout mice can be reversed by lumbar-level intrathecal orexin delivery. Orexin was delivered via a chronically implanted intrathecal catheter at the upper lumbar level. The computed tomographic scan confirmed that intrathecally administered contrast agent rapidly moved from the spinal cord to the brain. Intrathecally delivered orexin was detected in the brain by radioimmunoassay at levels comparable to endogenous orexin levels. Cataplexy and sleep-onset REM sleep were significantly decreased in orexin knockout mice during and long after slow infusion of orexin (1 nmol/1 µL/h). Sleep/wake states remained unchanged both quantitatively as well as qualitatively. Intrathecal orexin failed to induce any changes in double orexin receptor-1 and -2 knockout mice. This study supports the concept of intrathecal orexin delivery as a potential therapy for narcolepsy-cataplexy to improve the well-being of patients.

  4. Practical considerations and patient selection for intrathecal drug delivery in the management of chronic pain

    Directory of Open Access Journals (Sweden)

    Saulino M

    2014-11-01

    Full Text Available Michael Saulino,1,2 Philip S Kim,3,4 Erik Shaw5 1MossRehab, Elkins Park, PA, USA; 2Department of Rehabilitation Medicine, Jefferson Medical College, Philadelphia, PA, USA; 3Helen F Graham Cancer Center, Christiana Care Health System, Newark, DE, USA; 4Center for Interventional Pain Spine, LLC., Bryn Mawr, PA, USA; 5Shepherd Pain Institute, Shepherd Center, Atlanta, GA, USA Abstract: Chronic pain continues to pose substantial and growing challenges for patients, caregivers, health care professionals, and health care systems. By the time a patient with severe refractory pain sees a pain specialist for evaluation and management, that patient has likely tried and failed several nonpharmacologic and pharmacologic approaches to pain treatment. Although relegated to one of the interventions of “last resort”, intrathecal drug delivery can be useful for improving pain control, optimizing patient functionality, and minimizing the use of systemic pain medications in appropriately selected patients. Due to its clinical and logistical requirements, however, intrathecal drug delivery may fit poorly into the classic pain clinic/interventional model and may be perceived as a "critical mass" intervention that is feasible only for large practices that have specialized staff and appropriate office resources. Potentially, intrathecal drug delivery may be more readily adopted into larger practices that can commit the necessary staff and resources to support patients' needs through the trialing, initiation, monitoring, maintenance, and troubleshooting phases of this therapy. Currently, two agents – morphine and ziconotide – are approved by the United States Food and Drug Administration for long-term intrathecal delivery. The efficacy and safety profiles of morphine have been assessed in long-term, open-label, and retrospective studies of >400 patients with chronic cancer and noncancer pain types. The efficacy and safety profiles of ziconotide have been

  5. Thoracic Nerve Root Entrapment by Intrathecal Catheter Coiling: Case Report and Review of the Literature.

    Science.gov (United States)

    Han, Jing L; Loriaux, Daniel B; Tybout, Caroline; Kinon, Merritt D; Rahimpour, Shervin; Runyon, Scott L; Hopkins, Thomas J; Boortz-Marx, Richard L; Lad, Shivanand P

    2016-03-01

    Intrathecal catheter placement has long-term therapeutic benefits in the management of chronic, intractable pain. Despite the diverse clinical applicability and rising prevalence of implantable drug delivery systems in pain medicine, the spectrum of complications associated with intrathecal catheterization remains largely understudied and underreported in the literature. To report a case of thoracic nerve root entrapment resulting from intrathecal catheter migration. Case report. Inpatient hospital service. A 60-year-old man status post implanted intrathecal (IT) catheter for intractable low back pain secondary to failed back surgery syndrome returned to the operating room for removal of IT pump trial catheter after experiencing relapse of preoperative pain and pump occlusion. Initial attempt at ambulatory removal of the catheter was aborted after the patient reported acute onset of lower extremity radiculopathic pain during the extraction. Noncontrast computed tomography (CT) subsequently revealed that the catheter had ascended and coiled around the T10 nerve root. The patient was taken back to the operating room for removal of the catheter under fluoroscopic guidance, with possible laminectomy for direct visualization. Removal was ultimately achieved with slow continuous tension, with complete resolution of the patient's new radicular symptoms. This report describes a single case report. This case demonstrates that any existing loops in the intrathecal catheter during initial implantation should be immediately re-addressed, as they can precipitate nerve root entrapment and irritation. Reduction of the loop or extrication of the catheter should be attempted under continuous fluoroscopic guidance to prevent further neurosurgical morbidity.

  6. Delayed postoperative gastric emptying following intrathecal morphine and intrathecal bupivacaine.

    LENUS (Irish Health Repository)

    Lydon, A M

    2012-02-03

    PURPOSE: A decrease in the rate of gastric emptying can delay resumption of enteral feeding, alter bioavailability of orally administered drugs, and result in larger residual gastric volumes, increasing the risk of nausea and vomiting. We compared the effects of 1) intrathecal bupivacaine (17.5 mg) and 2) the combination of intrathecal morphine (0.6 mg) and intrathecal bupivacaine (17.5 mg) on the rate of gastric emptying in patients undergoing elective hip arthroplasty. METHODS: Twenty four fasting ASA 1-3 patients were randomly assigned, in a double blind manner, to receive intrathecal hyperbaric bupivacaine (17.5 mg), either alone (group 1), or followed by intrathecal morphine (0.6 mg) (group 2). Gastric emptying was measured (using an acetaminophen absorption technique), twice in each patient; preoperatively, and approximately one hour postoperatively. Gastric emptying parameters are: AUC (area under the plasma acetaminophen concentration time curve), maximum plasma acetaminophen concentration (Cmax), and time to Cmax (tCmax), analyzed using paired Student\\'s t tests. RESULTS: Gastric emptying rates were reduced in both group 1 (AUC = 14.98 (3.8) and 11.05 (4.6) pre- and postoperatively, respectively) and group 2 (AUC = 13.93 (3.59) and 6.4 (3.42) pre- and postoperatively, respectively); the magnitude of the reduction was greater in group 2 [AUC (P = 0.04), Cmax (P = 0.05), tCmax (P = 0.13)]. CONCLUSION: The combination of intrathecal morphine (0.6 mg) and intrathecal bupivacaine (17.5 mg) delays gastric emptying postoperatively.

  7. Intrathecal baclofen in multiple sclerosis and spinal cord injury: complications and long-term dosage evolution.

    Science.gov (United States)

    Draulans, Nathalie; Vermeersch, Kristof; Degraeuwe, Bart; Meurrens, Tom; Peers, Koen; Nuttin, Bart; Kiekens, Carlotte

    2013-12-01

    To investigate the long-term dosage evolution and complication rate of intrathecal baclofen use in multiple sclerosis and spinal cord injury patients, based on a large population with a long follow-up. Retrospective data analysis. Academic hospital. Patients with multiple sclerosis (n = 81) or spinal cord injury (n = 49) having an intrathecal baclofen pump implanted at the University Hospitals Leuven between 1988 and 2009. Medical records review of included patients in August 2010. Complications linked to intrathecal baclofen therapy. Daily baclofen dosage after 3 and 6 months, and yearly thereafter. Data on dosage evolution were analysed using a mixed-effect linear model. In 130 patients with a mean follow-up of 63 months, comprising 797 pump years, 104 complications were recorded. This corresponds to a complication rate of 0.011 per month, equally divided among both groups. Seventy-eight of these complications were catheter related. The mean dosage of baclofen stabilizes two years after implantation at 323 µg/day in the multiple sclerosis population. In spinal cord injury patients the daily dose only stabilizes after five years at a significantly higher dosage (504 µg/day). No significant increase in dosage is seen in the long term. In multiple sclerosis and spinal cord injury patients, intrathecal baclofen therapy has a complication rate of 1% per month. Complications are mainly due to catheter-related problems (74%). The intrathecal baclofen dosage stabilizes in the long term, indicating that long-term tolerance, defined as progressive diminution of the susceptibility to the effects of a drug, is not present.

  8. Intrathecal Baclofen Pump for Spasticity

    Science.gov (United States)

    2005-01-01

    Executive Summary Objective To conduct an evidence-based analysis of the effectiveness and cost-effectiveness of intrathecal baclofen for spasticity. The Technology Spasticity is a motor disorder characterized by tight or stiff muscles that may interfere with voluntary muscle movements and is a problem for many patients with multiple sclerosis (MS), spinal cord injury (SCI), cerebral palsy (CP), and acquired brain injury (ABI).(1). Increased tone and spasm reduces mobility and independence, and interferes with activities of daily living, continence and sleep patterns. Spasticity may also be associated with significant pain or discomfort (e.g., due to poor fit in braces, footwear, or wheelchairs), skin breakdown, contractures, sleep disorders and difficulty in transfer. Goals of treatment are to decrease spasticity in order to improve range of motion, facilitate movement, reduce energy expenditure and reduce risk of contractures. Existing treatments include physical therapy, oral medications, injections of phenol or botulinum toxin, or surgical intervention. Baclofen is the oral drug most frequently prescribed for spasticity in cases of SCI and MS.(1) Baclofen is a muscle relaxant and antispasticity drug. In the brain, baclofen delivered orally has some supraspinal activity that may contribute to clinical side effects. The main adverse effects of oral baclofen include sedation, excessive weakness, dizziness, mental confusion, and somnolence.(2) The incidence of adverse effects is reported to range from 10% to 75%.(2) Ochs et al. estimated that approximately 25-30% of SCI and MS patients fail to respond to oral baclofen.(3;4) Adverse effects appear to be dose-related and may be minimized by initiating treatment at a low dose and gradually titrating upwards.(2) Adverse effects usually appear at doses >60 mg/day.(2) The rate of treatment discontinuation due to intolerable adverse effects has generally been reported to range from 4% to 27%.(2) When baclofen is

  9. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  10. Intrathecal delivery of protein therapeutics to the brain: a critical reassessment.

    Science.gov (United States)

    Calias, Pericles; Banks, William A; Begley, David; Scarpa, Maurizio; Dickson, Patricia

    2014-11-01

    Disorders of the central nervous system (CNS), including stroke, neurodegenerative diseases, and brain tumors, are the world's leading causes of disability. Delivery of drugs to the CNS is complicated by the blood-brain barriers that protect the brain from the unregulated leakage and entry of substances, including proteins, from the blood. Yet proteins represent one of the most promising classes of therapeutics for the treatment of CNS diseases. Many strategies for overcoming these obstacles are in development, but the relatively straightforward approach of bypassing these barriers through direct intrathecal administration has been largely overlooked. Originally discounted because of its lack of usefulness for delivering small, lipid-soluble drugs to the brain, the intrathecal route has emerged as a useful, in some cases perhaps the ideal, route of administration for certain therapeutic protein and targeted disease combinations. Here, we review blood-brain barrier functions and cerebrospinal fluid dynamics and their relevance to drug delivery via the intrathecal route, discuss animal and human studies that have investigated intrathecal delivery of protein therapeutics, and outline several characteristics of protein therapeutics that can allow them to be successfully delivered intrathecally. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Intrathecal baclofen pump for spasticity: an evidence-based analysis.

    Science.gov (United States)

    2005-01-01

    To conduct an evidence-based analysis of the effectiveness and cost-effectiveness of intrathecal baclofen for spasticity. Spasticity is a motor disorder characterized by tight or stiff muscles that may interfere with voluntary muscle movements and is a problem for many patients with multiple sclerosis (MS), spinal cord injury (SCI), cerebral palsy (CP), and acquired brain injury (ABI).(1). Increased tone and spasm reduces mobility and independence, and interferes with activities of daily living, continence and sleep patterns. Spasticity may also be associated with significant pain or discomfort (e.g., due to poor fit in braces, footwear, or wheelchairs), skin breakdown, contractures, sleep disorders and difficulty in transfer. Goals of treatment are to decrease spasticity in order to improve range of motion, facilitate movement, reduce energy expenditure and reduce risk of contractures. Existing treatments include physical therapy, oral medications, injections of phenol or botulinum toxin, or surgical intervention. Baclofen is the oral drug most frequently prescribed for spasticity in cases of SCI and MS.(1) Baclofen is a muscle relaxant and antispasticity drug. In the brain, baclofen delivered orally has some supraspinal activity that may contribute to clinical side effects. The main adverse effects of oral baclofen include sedation, excessive weakness, dizziness, mental confusion, and somnolence.(2) The incidence of adverse effects is reported to range from 10% to 75%.(2) Ochs et al. estimated that approximately 25-30% of SCI and MS patients fail to respond to oral baclofen.(3;4) Adverse effects appear to be dose-related and may be minimized by initiating treatment at a low dose and gradually titrating upwards.(2) Adverse effects usually appear at doses >60 mg/day.(2) The rate of treatment discontinuation due to intolerable adverse effects has generally been reported to range from 4% to 27%.(2) When baclofen is administered orally, only a small portion of the

  12. Effect of intrathecal non-NMDA EAA receptor antagonist LY293558 in rats: a new class of drugs for spinal anesthesia.

    Science.gov (United States)

    Von Bergen, Nicholas H; Subieta, Alberto; Brennan, Timothy J

    2002-07-01

    Excitatory amino acid receptors are important for both sensory and motor function in the spinal cord. We studied the effects of intrathecal LY293558, a competitive non-N-methyl-D-aspartate excitatory amino acid receptor antagonist, on motor and sensory function in rats to determine whether drugs blocking these receptors could potentially be used as alternative agents to local anesthetics for spinal anesthesia. Rats were tested before and 15-240 min after intrathecal injection of 5 nmol (in 10 microl) LY293558. Sensory function was tested at the hind paw using withdrawal response to pin prick and withdrawal to pinch with sharp forceps. Motor performance (ambulation, placing reflex, and Rotorod time), blood pressure, and heart rate were also evaluated. Some tests were repeated the next day. Responses after LY293558 were compared to injection of 40 microl bupivacaine, 0.75%. Pin-prick responses at the forepaw, chest, abdomen, hind leg, and hind paw were also examined after intrathecal LY293558. Intrathecal LY293558 blocked both sensory and motor responses through 180 min; complete recovery was present the following day. No change in blood pressure or heart rate occurred. The effects of LY293558 were more pronounced and sustained than those of bupivacaine. Segmental blockade of the response to pin prick was present after LY293558. Drugs like LY293558 that block alpha-amino-3-hydroxy-5-methyl-4-isoxazole-propionic acid (AMPA)/kainate receptors may be an alternative to local anesthetics for spinal anesthesia in humans.

  13. Practical aspects of the use of intrathecal chemotherapy

    OpenAIRE

    Olmos-Jiménez, Raquel; Espuny-Miró, Alberto; Cárceles-Rodríguez, Carlos; Díaz-Carrasco, María Sacramento

    2017-01-01

    Abstract Introduction: Intrathecal chemotherapy is frequently used in clinical practice for treatment and prevention of neoplastic meningitis. Despite its widespread use, there is little information about practical aspects such as the volume of drug to be administered or its preparation and administration. Objective: To conduct a literature review about practical aspects of the use of intrathecal chemotherapy. Materials: Search in PubMed/ Medline using the terms “chemotherapy AND intrat...

  14. 'Was it worth it?' Intrathecal analgesia for cancer pain: A qualitative study exploring the views of family carers.

    Science.gov (United States)

    Patel, Nishi; Huddart, Melanie; Makins, Helen; Mitchell, Theresa; Gibbins, Jane L; Graterol, Juan; Stevens, Deborah; Perkins, Paul

    2018-01-01

    Intrathecal drug delivery is known to reduce pain in patients where conventional systemic analgesia has been ineffective or intolerable. However, there is little information regarding the effects of intrathecal drug delivery on quality of life and function in those with advanced, incurable cancer. Retrospective exploration of the views of bereaved carers regarding the physical and psychosocial effects of external tunnelled intrathecal drug delivery in patients with advanced incurable cancer. Thematic analysis of qualitative interviews with carers of deceased individuals who received percutaneous external tunnelled intrathecal drug delivery as part of their pain management, within two UK centres. A total of 11 carers were recruited from two UK Palliative Care centres. Family carers of adult patients who had received external tunnelled intrathecal drug delivery analgesia for cancer pain and had died between 6 and 48 months prior to contact were included. Carer relatives who were considered likely to be too vulnerable or who had lodged a complaint about treatment within the recruiting department or who had been treated directly by the interviewer were excluded. In total, 11 interviews took place. The emerging themes were (1) making the decision to have the intrathecal - relatives described desperate situations with severe pain and/or sedation, meaning that the individual would try anything; (2) timing and knowing they were having the best - an increased access to pain and palliative care services, meant carers felt everything possible was being done, making the situation more bearable; (3) was it worth it? - the success of the external tunnelled intrathecal drug delivery was judged on its ability to enable the individual to be themselves through their final illness. Side effects were often considered acceptable, if the external tunnelled intrathecal drug delivery enabled improvements in quality of life. Carers perceived external tunnelled intrathecal drug delivery

  15. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  16. Intrathecal tramadol versus intrathecal fentanyl for visceral pain ...

    African Journals Online (AJOL)

    Intrathecal tramadol versus intrathecal fentanyl for visceral pain control during bupivacaine subarachnoid block for open appendicectomy. ... Visual analog scale scores and frequency of subjective symptoms among patients in the three groups formed the primary outcome measure of this study. Results: Effective ...

  17. Inadvertent intrathecal injection of atracurium.

    Science.gov (United States)

    Zirak, Nahid; Soltani, Ghasem; Ghomian, Naiere; Hasanpour, Mohamad Reza; Mashayekhi, Zahra

    2011-04-01

    This report relates how tracurium was given by mistake, intrathecally, during spinal anesthesia, to a 38-year-old woman, who was a candidate for abdominal hysterectomy. When no analgesia was observed, the mistake in giving the injection was understood. She was evaluated postoperatively by train of four ratio, measuring her breathing rate, eye opening, and protruding of tongue at one, two, twenty-four, and forty-eight hours, and then at one and two weeks, with the final evaluation the following month. The patient had normal timings during the operation and postoperation periods, and no abnormal findings were observed through the first month. This finding was contrary to several studies, which described adverse reactions due to accidental intrathecal injection of neuromuscular blocking drugs.

  18. Inadvertent intrathecal injection of atracurium

    Directory of Open Access Journals (Sweden)

    Nahid Zirak

    2011-01-01

    Full Text Available This report relates how tracurium was given by mistake, intrathecally, during spinal anesthesia, to a 38-year-old woman, who was a candidate for abdominal hysterectomy. When no analgesia was observed, the mistake in giving the injection was understood. She was evaluated postoperatively by train of four ratio, measuring her breathing rate, eye opening, and protruding of tongue at one, two, twenty-four, and forty-eight hours, and then at one and two weeks, with the final evaluation the following month. The patient had normal timings during the operation and postoperation periods, and no abnormal findings were observed through the first month. This finding was contrary to several studies, which described adverse reactions due to accidental intrathecal injection of neuromuscular blocking drugs.

  19. Intrathecal nalbuphine versus intrathecal fentanyl as adjuvant to 0.5% hyperbaric bupivacaine for orthopedic surgery of lower limbs under subarachnoid block: A comparative evaluation

    Directory of Open Access Journals (Sweden)

    Kumkum Gupta

    2016-01-01

    Full Text Available Background: Subarachnoid block (SAB possesses many benefits with a drawback of short duration of anesthetic action. Intrathecal opioids have been used to enhance the clinical efficiency and duration of action of local anesthetic drugs. The present study was aimed to compare the clinical efficiency of intrathecal fentanyl with nalbuphine as adjuvant to 0.5% hyperbaric bupivacaine for orthopedic surgery of lower limbs. Patients and Methods: Sixty-eight adult patients of American Society of Anesthesiologist physical status I and II of both gender aged 25-65 years were randomized into two groups of 34 each to receive either fentanyl 25 μg (Group I or nalbuphine 2 mg (Group II with 3.5 mL 0.5% hyperbaric bupivacaine, making intrathecal drug volume to 4 mL in each group. Sensory and motor block characteristics and time to first rescue analgesic (intravenous tramadol 100 mg were recorded as the primary end points. Drug-related side effects of pruritus, nausea/vomiting, and respiratory depression were recorded as the secondary outcomes. Results: Both groups were comparable regarding the onset and cephalic extension of block. The time to two dermatome regressions and time for complete motor recovery were significantly prolonged in patients of Group II with statistical significant difference (P < 0.05. Duration of analgesia was also extended in patients of Group II (378.0 ± 35.72 min as compared to Group I (234.0 ± 24.10 min with highly significant difference (P < 0.001. No drug-related side effects were observed in either group. Conclusion: Intrathecal nalbuphine 2 mg as adjuvant to 0.5% bupivacaine was clinically more efficient than fentanyl for enhancing the postoperative analgesia.

  20. Chronic intrathecal cannulation enhances nociceptive responses in rats

    Directory of Open Access Journals (Sweden)

    Almeida F.R.C.

    2000-01-01

    Full Text Available The influence of a chronically implanted spinal cannula on the nociceptive response induced by mechanical, chemical or thermal stimuli was evaluated. The hyperalgesia in response to mechanical stimulation induced by carrageenin or prostaglandin E2 (PGE2 was significantly increased in cannulated (Cn rats, compared with naive (Nv or sham-operated (Sh rats. Only Cn animals presented an enhanced nociceptive response in the first phase of the formalin test when low doses were used (0.3 and 1%. The withdrawal latency to thermal stimulation of a paw inflamed by carrageenin was significantly reduced in Cn rats but not in Nv or Sh rats. In contrast to Nv and Sh rats, injection in Cn animals of a standard non-steroid anti-inflammatory drug, indomethacin, either intraperitoneally or into the spinal cord via an implanted cannula or by direct puncture of the intrathecal space significantly blocked the intensity of the hyperalgesia induced by PGE2. Cannulated animals treated with indomethacin also showed a significant inhibition of second phase formalin-induced paw flinches. Histopathological analysis of the spinal cord showed an increased frequency of mononuclear inflammatory cells in the Cn groups. Thus, the presence of a chronically implanted cannula seems to cause nociceptive spinal sensitization to mechanical, chemical and thermal stimulation, which can be blocked by indomethacin, thus suggesting that it may result from the spinal release of prostaglandins due to an ongoing mild inflammation.

  1. Respiratory failure following delayed intrathecal morphine pump refill: a valuable, but costly lesson.

    Science.gov (United States)

    Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas

    2010-01-01

    Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of

  2. Use of Intrathecal Fluorescein in Recurrent Meningitis after Cochlear Implantation-A Case Report

    Directory of Open Access Journals (Sweden)

    Swati Tandon

    2016-05-01

    Full Text Available Introduction: Congenital anomalies of the cochlea and labyrinth can be associated with meningitis and varying degrees of hearing loss or deafness. Despite antibiotics, meningitis remains a life threatening complication.   Case Report: We report a case of recurrent meningitis following episodes of otitis media in a cochlear implantee child with bilateral vestibulocochlear malformation, due to fistula in the stapes footplate. Intrathecal fluorescin was used to identify the leak site.   Conclusion:  Recurrent meningitis can indicate for possible immunological or anatomical abnormalities as well for chronic parameningeal infections. Intraoperative use of intrathecal fluorescin is an ideal investigative tool to demonstrate cerebrospinal fluid (CSF leak site in patients in whom other investigations fail to do so.

  3. Minimum effective local anesthetic dose of intrathecal hyperbaric ropivacaine and bupivacaine for cesarean section

    Institute of Scientific and Technical Information of China (English)

    GENG Zhi-yu; WANG Dong-xin; WU Xin-min

    2011-01-01

    Background Intrathecal anesthesia is commonly used for cesarean section. Bupivacaine and ropivacaine have all been used as intrathecal drugs. The minimum effective local anesthetic dose (MLAD) of intrathecal ropivacaine for nonobstetric patients has been reported. However, few data are available on the MLAD of hyperbaric ropivacine for obstetric patients and the relative potency to bupivacaine has not been fully determined. In this study, we sought to determine the MLAD of intrathecal ropivacaine and bupivacaine for elective cesarean section and to define their relative potency ratio.Methods We enrolled forty parturients undergoing elective cesarean section under combined spinal-epidural anesthesia and randomized them to one of two groups to receive intrathecal 0.5% hyperbaric ropivacaine or bupivacaine.The initial dose was 10 mg, and was increased in increments of 1 mg, using the technique of up-down sequential allocation. Efficacy was accepted if adequate sensory dermatomal anesthesia to pin prick to T7 or higher was attained within 20 minutes after intrathecal injection, and required no supplementary epidural injection for procedure until at least 50 minutes after the intrathecal injection.Results The intrathecal MLAD was 9.45 mg (95%confidence interval (CI), 8.45-10.56 mg) for ropivacaine and 7.53 mg (95%CI, 7.00-8.10 mg) for bupivacaine. The relative potency ratio was 0.80 (95% Cl, 0.74-0.85) for ropivacaine/bupivacaine when given intrathecally in cesarean section.Conclusion Ropivacaine is 20% less potent than bupivacaine during intrathecal anesthesia for cesarean delivery.

  4. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  5. Intrathecal isobaric ropivacaine-fentanyl versus intrathecal isobaric bupivacaine-fentanyl for labor analgesia: A controlled comparative double-blinded study

    Directory of Open Access Journals (Sweden)

    Meenoti Pramod Potdar

    2014-01-01

    Full Text Available Context: Neuraxial analgesia and walking epidural is the popular method of practicing labor analgesia. The combination of local anesthetic and opioid is advantageous as it prolongs the duration of labor analgesia. Ropivacaine is the newer local anesthetic agent having lesser motor effects and toxic effects hence would be preferred for labor analgesia. Aims: The primary objective of the study was to assess the duration of analgesia of the intrathecal drug. The secondary objective was the assessment of onset, fixation of analgesia, motor weakness, ambulation, sedation, incidence of side-effects, maternal, and neonatal outcomes. Settings and Design: This is prospective, randomized, controlled, double-blinded, study of 120 patients consenting for labor analgesia. Subjects and Methods: A total of 120 primiparas with a singleton pregnancy in active labor who were given combined spinal epidural (CSE were included in the study. These patients were randomly allocated to three groups of 40 each and received CSE. Group F-received 25 μcg fentanyl intrathecally. Group BF-received 25 μcg fentanyl with 2.5 mg isobaric bupivacaine intrathecally. Group RF-received 25 μcg fentanyl with 2.5 mg isobaric ropivacaine intrathecally. Statistical Analysis Used: Correlations among different measurements were assessed using Pearson′s correlation coefficients, P <0.05 was considered to be statistically significant. Results: The three groups show comparable demographic data and obstetric parameters. The duration of spinal analgesia was significantly greater with Group RF 106.63 ± 17.99 min and Group BF 111.75 ± 23.58 min than the control Group F which was 60 ± 10.39 min with P = 0.001, but were comparable for Group BF and RF. The secondary outcome was comparable in all the three groups. Conclusions: The addition of bupivacaine or ropivacaine to fentanyl intrathecally increased duration and quality of analgesia, did not affect ambulation and bearing down. The

  6. Intrathecal Ropivacaine in Cesarean Delivery

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Conclusion: Ropivacaine administration produced rapid induction of ... KEYWORDS: Ropivacaine, spinal anesthesia, intrathecal, cesarean section. Intrathecal .... expressed as mean standard deviation (SD). One-way.

  7. Design of Drug Delivery Methods for the Brain and Central Nervous System

    Science.gov (United States)

    Lueshen, Eric

    Due to the impermeability of the blood-brain barrier (BBB) to macromolecules delivered systemically, drug delivery to the brain and central nervous system (CNS) is quite difficult and has become an area of intense research. Techniques such as convection-enhanced intraparenchymal delivery and intrathecal magnetic drug targeting offer a means of circumventing the blood-brain barrier for targeted delivery of therapeutics. This dissertation focuses on three aspects of drug delivery: pharmacokinetics, convection-enhanced delivery, and intrathecal magnetic drug targeting. Classical pharmacokinetics mainly uses black-box curve fitting techniques without biochemical or biological basis. This dissertation advances the state-of-the-art of pharmacokinetics and pharmacodynamics by incorporating first principles and biochemical/biotransport mechanisms in the prediction of drug fate in vivo. A whole body physiologically-based pharmacokinetics (PBPK) modeling framework is engineered which creates multiscale mathematical models for entire organisms composed of organs, tissues, and a detailed vasculature network to predict drug bioaccumulation and to rigorously determine kinetic parameters. These models can be specialized to account for species, weight, gender, age, and pathology. Systematic individual therapy design using the proposed mechanistic PBPK modeling framework is also a possibility. Biochemical, anatomical, and physiological scaling laws are also developed to accurately project drug kinetics in humans from small animal experiments. Our promising results demonstrate that the whole-body mechanistic PBPK modeling approach not only elucidates drug mechanisms from a biochemical standpoint, but offers better scaling precision. Better models can substantially accelerate the introduction of drug leads to clinical trials and eventually to the market by offering more understanding of the drug mechanisms, aiding in therapy design, and serving as an accurate dosing tool. Convection

  8. Intentional intrathecal opioid detoxification in 3 patients: characterization of the intrathecal opioid withdrawal syndrome.

    Science.gov (United States)

    Jackson, Tracy P; Lonergan, Daniel F; Todd, R David; Martin, Peter R

    2013-04-01

    Intrathecal (IT) drug delivery systems for patients with chronic non-malignant pain are intended to improve pain and quality of life and reduce side effects of systemic use. A subset of patients may have escalating pain, functional decline, and/or intolerable side effects even as IT opioid doses are increased. Discontinuation of IT medications may represent a viable treatment option but strategies to accomplish this are needed. Three patients with intrathecal drug delivery systems (IDDS), inadequate pain control, and declining functionality underwent abrupt IT opioid cessation. This was accomplished through a standardized protocol with symptom-triggered administration of clonidine and buprenorphine, monitored using the clinical opiate withdrawal scale. Symptoms of IT withdrawal were similar in all patients and included diuresis, agitation, hyperalgesia, mild diarrhea, yawning, and taste and smell aversion. Hypertension and tachycardia were effectively controlled by clonidine administration. Classic symptoms of withdrawal, such as piloerection, chills, severe diarrhea, nausea, vomiting, diaphoresis, myoclonus, and mydriasis, were not noted. At 2 to 3 months follow-up, patients reported decreased, but ongoing pain, with improvements in functional capacity and quality of life. This preliminary work demonstrates the safety of abrupt IT opioid cessation utilizing standardized inpatient withdrawal protocols. To our knowledge, these are among the first reported cases of intentional, controlled IT opioid cessation without initiation of an opioid bridge: self-reported pain scores, functional capacity, and quality of life improved. The IT opioid withdrawal syndrome is characterized based upon our observations and a review of the literature. © 2012 The Authors. Pain Practice © 2012 World Institute of Pain.

  9. Postoperative analgesia and antiemetic efficacy after intrathecal neostigmine in patients undergoing abdominal hysterectomy during spinal anesthesia.

    Science.gov (United States)

    Lauretti, G R; Mattos, A L; Gomes, J M; Pereira, N L

    1997-01-01

    Postoperative analgesia and antiemetic efficacy after intrathecal neostigmine were investigated in a randomized, double-blind, placebo-controlled trial of 100 patients undergoing abdominal hysterectomy. The patients were assigned to one of five groups (n = 20), and received intravenous prior to the spinal block the antiemetic test drug (except propofol) and 0.05 mg/kg midazolam. The control group (group C), the neostigmine group (group N), and the propofol group (group P) received saline as the test drug. The droperidol group (group D) received 0.5 mg intravenous droperidol, and the metoclopramide group (group M) 10 mg intravenous metoclopramide. Group P was single-blinded and had an intravenous continuous propofol infusion (2-4 mg/kg/h) turned on 10 minutes after the spinal injection. The intrathecal drugs administered were 20 mg hyperbaric bupivacaine (0.5%) associated with either 100 microg neostigmine or saline (for group C). Nausea, emetic episodes, and the need for rescue medication were recorded for the first 24 hours postoperative and scored by the Visual Analog Scale (VAS). Time-to-first-rescue medication and rescue medications in 24 hours were similar among the groups (P = .2917 and P = .8780, respectively). Intrathecal 100 microg neostigmine was associated with a high incidence of nausea and vomiting perioperative, leading to a high consumption of antiemetics (P antiemetic test drugs were effective in preventing nausea and vomiting after 100 microg neostigmine. Intrathecal neostigmine (100 microg) was ineffective for postoperative analgesia after abdominal hysterectomy due to side effects of nausea and vomiting.

  10. Intrathecal Bupivacaine Monotherapy with a Retrograde Catheter for the Management of Complex Regional Pain Syndrome of the Lower Extremity.

    Science.gov (United States)

    McRoberts, W Porter; Apostol, Catalina; Haleem, Abdul

    2016-01-01

    Complex regional pain syndrome (CRPS) presents a therapeutic challenge due to its many presentations and multifaceted pathophysiology. There is no approved treatment algorithm and clinical interventions are often applied empirically. In cases of CRPS where symptoms are localized to an extremity, a targeted treatment is indicated. We describe the use of intrathecal bupivacaine monotherapy, delivered through a retrograde catheter, in the treatment of CRPS affecting the lower extremity. The patient, a 57-year-old woman with a history of failed foot surgery, was seen in our office after 2 years of ineffective treatments with local blocks and neurolytic procedures. We advanced therapy to moderately invasive procedures with an emphasis on neuromodulation. A combined central and peripheral stimulation technique that initially provided 75% pain relief, failed to provide lasting analgesia. We proceeded with an intrathecal pump implant. Based on the results of dorsal root ganglion (DRG) mapping, L5-S1 was identified as the optimal target for therapy and a retrograde catheter was placed at this level. Various intrathecal medications were tested individually. An intrathecal morphine trial was ineffective (visual analog scale [VAS] 7), while intrathecal clonidine provided excellent pain relief (VAS 0) that was limited by severe side effects. Bupivacaine provided 100% analgesia with tolerable side effects (lower extremity weakness and minor bladder incontinence) and was selected for intrathecal infusion. After 14 months, bupivacaine treatment continued to control pain exacerbations. We conclude that CRPS patients benefit from early identification of the predominant underlying symptoms and a targeted treatment with moderately invasive techniques when less invasive techniques fail. Intrathecal bupivacaine, bupivacaine monotherapy, retrograde catheter, complex regional pain syndrome (CRPS), dual stimulation, dosal root ganglion (DRG) testing.

  11. A comparison of intrathecal dexmedetomidine verses intrathecal fentanyl with epidural bupivacaine for combined spinal epidural labor analgesia

    Directory of Open Access Journals (Sweden)

    P K Dilesh

    2014-01-01

    Conclusion: 10 μg dexmedetomidine intrathecally provides a longer duration of analgesia with lesser incidence of pruritus compared to 20 μg fentanyl intrathecally for CSE labor analgesia with comparable neonatal side-effects.

  12. Intrathecal tramadol versus intrathecal fentanyl for visceral pain ...

    African Journals Online (AJOL)

    2013-10-29

    Oct 29, 2013 ... Nigerian Journal of Clinical Practice • May-Jun 2014 • Vol 17 • Issue 3. Original ... intrathecal fentanyl and a normal saline placebo‑controlled protocol for ..... pain experienced by pregnant women during Caesarean section.

  13. Biodistribution of Idursulfase Formulated for Intrathecal Use (Idursulfase-IT in Cynomolgus Monkeys after Intrathecal Lumbar Administration.

    Directory of Open Access Journals (Sweden)

    Jou-Ku Chung

    Full Text Available Enzyme replacement therapy with intravenous idursulfase (recombinant iduronate-2-sulfatase is approved for the treatment of Hunter syndrome. Intravenous administration does not, however, treat the neurological manifestations, due to its low central nervous system bioavailability. Using intrathecal-lumbar administration, iduronate-2-sulfatase is delivered directly to the central nervous system. This study investigates the central nervous system biodistribution of intrathecal-lumbar administered iduronate-2-sulfatase in cynomolgus monkeys. Twelve monkeys were administered iduronate-2-sulfatase in one 30 mg intrathecal-lumbar injection. Brain, spinal cord, liver, and kidneys were collected for iduronate-2-sulfatase concentration (measured by an enzyme linked immunosorbent assay and enzyme activity measurement (via a method utilizing 4-methylumbelliferyl-α-iduronate-2-sulfate at 1, 2, 5, 12, 24, and 48 hours following administration. The tissue enzyme linked immunosorbent assay confirmed iduronate-2-sulfatase uptake to the brain, spinal cord, kidneys, and liver in a time-dependent manner. In spinal cord and brain, iduronate-2-sulfatase appeared as early as 1 hour following administration, and peak concentrations were observed at ~2 and ~5 hours. Iduronate-2-sulfatase appeared in liver and kidneys 1 hour post intrathecal-lumbar dose with peak concentrations between 5 and 24 hours. Liver iduronate-2-sulfatase concentration was approximately 10-fold higher than kidney. The iduronate-2-sulfatase localization and enzyme activity in the central nervous system, following intrathecal administration, demonstrates that intrathecal-lumbar treatment with iduronate-2-sulfatase may be considered for further investigation as a treatment for Hunter syndrome patients with neurocognitive impairment.

  14. Italian multicentre study on intrathecal fluorescein for craniosinusal fistulae.

    Science.gov (United States)

    Felisati, G; Bianchi, A; Lozza, P; Portaleone, S

    2008-08-01

    Cerebrospinal fluid leak (CSF), clinical sign of a dural lesion of the skull base, is a relatively rare event that can present with a variety of symptoms. Every craniosinus fistula should be considered a serious, potentially life-threatening situation (even those cases with hidden CSF leak). Reports of experience concerning diagnosis and treatment of craniosinus fistulae have appeared in the Literature. In the last few years, the endoscopic nasal approach is proving effective as it makes diagnosis much easier and is the least invasive surgical approach, with the greatest percentage of success. Various classifications are being proposed to improve clinical evaluation of CSF leaks and to simplify the diagnostic and therapeutic approach. The most common parameters of classification are: aetiology (traumatic, iatrogenic, non-traumatic, etc.) site, type of flow (high or low pressure) and, as far as concerns treatment, the type of graft used, all of which have contributed to various diagnostic and therapeutic algorithms being proposed. Therefore, the subject seems to be widely schematized and the therapeutic attitude widely agreed. However, one of the diagnostic and therapeutic approaches is now being questioned. For some, it is the heart of the clinical approach, while for others, it is a useful tool yet too dangerous to be used on account of potential side effects: namely, the fluorescein test. This procedure, consisting of intrathecal injection of a colorant (fluorescein), is well known by the Food and Drug Administration (FDA) which neither explicitly prohibits it, nor allows it, intrathecal administration is, therefore, an off label use. As far as the Authors know, authorization of this procedure has not been forthcoming anywhere in the world although the procedure itself is widely employed. As far as concerns the use of intrathecal fluorescein, many scientific papers have been written, clearly supporting its clinical usefulness. One limit to the use of fluorescein

  15. Effects of intrathecal lidocaine on hyperalgesia and allodynia following chronic constriction injury in rats.

    Science.gov (United States)

    Tian, Jie; Gu, Yiwen; Su, Diansan; Wu, Yichao; Wang, Xiangrui

    2009-02-01

    The present study investigated the effects of different doses of intrathecal lidocaine on established thermal hyperalgesia and tactile allodynia in the chronic constriction injury model of neuropathic pain, defined the effective drug dose range, the duration of pain-relief effects, and the influence of this treatment on the body and tissues. Male Sprague-Dawley rats were divided into five groups and received intrathecal saline or lidocaine (2, 6.5, 15, and 35 mg/kg) 7 days after loose sciatic ligation. Respiratory depression and hemodynamic instability were found to become more severe as doses of lidocaine increased during intrathecal therapy. Two animals in the group receiving 35 mg/kg lidocaine developed pulmonary oedema and died. Behavioral tests indicated that 6.5, 15, and 35 mg/kg intrathecal lidocaine showed different degrees of reversal of thermal hyperalgesia, and lasted for 2-8 days, while 2 mg/kg lidocaine did not. The inhibition of tactile allodynia was only observed in rats receiving 15 and 35 mg/kg lidocaine, and the anti-allodynic effects were identical in these two groups. Histopathologic examinations on the spinal cords revealed mild changes in rats receiving 2-15 mg/kg lidocaine. However, lesions were severe after administration of 35 mg/kg lidocaine. These findings indicate that intrathecal lidocaine has prolonged therapeutic effects on established neuropathic pain. The balance between sympathetic and parasympathetic nervous activities could be well preserved in most cases, except for 35 mg/kg. Considering the ratio between useful effects and side effects, doses of 15 mg/kg are suitable for intrathecal injection for relief of neuropathic pain.

  16. Fluconazole and intrathecal injection of amphotericin B for treating cryptococcal meningitis

    Institute of Scientific and Technical Information of China (English)

    Shiguang Wen; Jian Yin; Shaosen Qin; Meiping Wen; Xiaoyan Zhang; Dongke Chen

    2006-01-01

    intracranial hypertension,were used at the same time of administration. When cryptococcus of cerebrospinal fluid was negative, patients received the secondary therapy at anaphase. The drug withdrawal was not performed untill ink smear of cerebrospinal fluid was negative for 3 successive cultures. ③ Evaluative criteria: Evaluative criteria were classified into 4 styles: Cure: Clinical symptoms and physical signs disappeared and ink smear of cerebrospinal fluid was negative for 3 successful cultures; Improvement: Clinical symptoms and physical signs were improved remarkably, amount of cerebrospinal fluid was decreased, and ink smear was not negative; inefficiency and death.MAIN OUTCOME MEASURE: Clinical effects and poor responses of intrathecal injection of amphotericin B and fluconazole treatment.RESULTS: Among 8 patients with cryptococcal meningitis, one died due to ntracranial hypertension combining with cerebral hernia, and others were returned visit at 1 year after drug withdrawal. ① Clinical effects: Among 8patients with cryptococcal meningitis, 4 were cured, 3 were improved, and one died. There was no relapse case. ② Results of mycological examination: After first intrathecal injection of 4 improved patients, the amount of cryptococcus of cerebrospinal fluid was decreased 20%-30%; in addition, after intrathecal injection for twice or three times, the amount was decreased 33%-50%. ③ Improvement of intracranial hypertension: Seven patients had the intracranial hypertension. After intrathecal injection for twice or three times, pressure of cerebrospinal fluid was decreased below 2 451.75 Pa, and the clinical symptoms were relieved remarkably. ④Poor responses: After intrathecal injection, patients had headache, nausea, emesis and pain of lower limb.Especially, 2 cases had transient paraplegia of both lower limbs, one had retention of urine, and two had conscious disturbance.CONCLUSrON: Controlling intracranial hypertension with repeatedly piercing waist and

  17. Targeted drug delivery to magnetic implants for therapeutic applications

    International Nuclear Information System (INIS)

    Yellen, Benjamin B.; Forbes, Zachary G.; Halverson, Derek S.; Fridman, Gregory; Barbee, Kenneth A.; Chorny, Michael; Levy, Robert; Friedman, Gary

    2005-01-01

    A new method for locally targeted drug delivery is proposed that employs magnetic implants placed directly in the cardiovascular system to attract injected magnetic carriers. Theoretical simulations and experimental results support the assumption that using magnetic implants in combination with externally applied magnetic field will optimize the delivery of magnetic drug to selected sites within a subject

  18. Antinociceptive effect of intrathecal microencapsulated human pheochromocytoma cell in a rat model of bone cancer pain.

    Science.gov (United States)

    Li, Xiao; Li, Guoqi; Wu, Shaoling; Zhang, Baiyu; Wan, Qing; Yu, Ding; Zhou, Ruijun; Ma, Chao

    2014-07-08

    Human pheochromocytoma cells, which are demonstrated to contain and release met-enkephalin and norepinephrine, may be a promising resource for cell therapy in cancer-induced intractable pain. Intrathecal injection of alginate-poly (l) lysine-alginate (APA) microencapsulated human pheochromocytoma cells leads to antinociceptive effect in a rat model of bone cancer pain, and this effect was blocked by opioid antagonist naloxone and alpha 2-adrenergic antagonist rauwolscine. Neurochemical changes of cerebrospinal fluid are in accordance with the analgesic responses. Taken together, these data support that human pheochromocytoma cell implant-induced antinociception was mediated by met-enkephalin and norepinephrine secreted from the cell implants and acting at spinal receptors. Spinal implantation of microencapsulated human pheochromocytoma cells may provide an alternative approach for the therapy of chronic intractable pain.

  19. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  20. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management

    Directory of Open Access Journals (Sweden)

    Dharani Manickavasagam

    2013-01-01

    Full Text Available Glaucoma is a group of heterogeneous disorders involving progressive optic neuropathy that can culminate into visual impairment and irreversible blindness. Effective therapeutic interventions must address underlying vulnerability of retinal ganglion cells (RGCs to degeneration in conjunction with correcting other associated risk factors (such as elevated intraocular pressure. However, realization of therapeutic outcomes is heavily dependent on suitable delivery system that can overcome myriads of anatomical and physiological barriers to intraocular drug delivery. Development of clinically viable sustained release systems in glaucoma is a widely recognized unmet need. In this regard, implantable delivery systems may relieve the burden of chronic drug administration while potentially ensuring high intraocular drug bioavailability. Presently there are no FDA-approved implantable drug delivery devices for glaucoma even though there are several ongoing clinical studies. The paper critically assessed the prospects of polymeric implantable delivery systems in glaucoma while identifying factors that can dictate (a patient tolerability and acceptance, (b drug stability and drug release profiles, (c therapeutic efficacy, and (d toxicity and biocompatibility. The information gathered could be useful in future research and development efforts on implantable delivery systems in glaucoma.

  1. Characterization of drug-release kinetics in trabecular bone from titania nanotube implants

    Directory of Open Access Journals (Sweden)

    Aw MS

    2012-09-01

    Full Text Available Moom Sinn Aw,1 Kamarul A Khalid,2,3 Karan Gulati,1 Gerald J Atkins,2 Peter Pivonka,4 David M Findlay,2 Dusan Losic11School of Chemical Engineering, 2Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, SA, Australia; 3Department of Orthopaedics, Traumatology and Rehabilitation, Faculty of Medicine, International Islamic University Malaysia, Kuantan, Pahang, Malaysia; 4Engineering Computational Biology Group, School of Computer Science and Software Engineering, The University of Western Australia, Perth, WA, AustraliaPurpose: The aim of this study was to investigate the application of the three-dimensional bone bioreactor for studying drug-release kinetics and distribution of drugs in the ex vivo cancellous bone environment, and to demonstrate the application of nanoengineered titanium (Ti wires generated with titania nanotube (TNT arrays as drug-releasing implants for local drug deliveryMethods: Nanoengineered Ti wires covered with a layer of TNT arrays implanted in bone were used as a drug-releasing implant. Viable bovine trabecular bone was used as the ex vivo bone substrate embedded with the implants and placed in the bone reactor. A hydrophilic fluorescent dye (rhodamine B was used as the model drug, loaded inside the TNT–Ti implants, to monitor drug release and transport in trabecular bone. The distribution of released model drug in the bone was monitored throughout the bone structure, and concentration profiles at different vertical (0–5 mm and horizontal (0–10 mm distances from the implant surface were obtained at a range of release times from 1 hour to 5 days.Results: Scanning electron microscopy confirmed that well-ordered, vertically aligned nanotube arrays were formed on the surface of prepared TNT–Ti wires. Thermogravimetric analysis proved loading of the model drug and fluorescence spectroscopy was used to show drug-release characteristics in-vitro. The drug release from implants inserted into bone ex

  2. A comparison between post-operative analgesia after intrathecal nalbuphine with bupivacaine and intrathecal fentanyl with bupivacaine after cesarean section

    Directory of Open Access Journals (Sweden)

    Hala Mostafa Gomaa

    2014-10-01

    Conclusion: Either intrathecal nalbuphine 0.8 mg or intrathecal fentanyl 25 μg combined with 10 mg bupivacaine provides good intra-operative and early post-operative analgesia in cesarean section.

  3. Safety and efficacy of intrathecal ziconotide in the management of severe chronic pain

    Directory of Open Access Journals (Sweden)

    Howard S Smith

    2009-07-01

    Full Text Available Howard S Smith,1 Timothy R Deer21Albany Medical College, Department of Anesthesiology, Albany, New York, USA; 2The Center for Pain Relief, Clinical Professor, West Virginia, University, Charleston, West Virginia, USAAbstract: Ziconotide is a conopeptide intrathecal (IT analgesic which is approved by the US Food and Drug Administration (FDA for the management of severe chronic pain. It is a synthetic equivalent of a naturally occurring conopeptide found in the venom of the fish-eating marine cone snail and provides analgesia via binding to N-type voltage-sensitive calcium channels in the spinal cord. As ziconotide is a peptide, it is expected to be completely degraded by endopeptidases and exopeptidases (Phase I hydrolytic enzymes widely located throughout the body, and not by other Phase I biotransformation processes (including the cytochrome P450 system or by Phase II conjugation reactions. Thus, IT administration, low plasma ziconotide concentrations, and metabolism by ubiquitous peptidases make metabolic interactions of other drugs with ziconotide unlikely. Side effects of ziconotide which tend to occur more commonly at higher doses may include: nausea, vomiting, confusion, postural hypotension, abnormal gait, urinary retention, nystagmus/amblyopia, drowsiness/somnolence (reduced level of consciousness, dizziness or lightheadedness, weakness, visual problems (eg, double vision, elevation of serum creatine kinase, or vestibular side effects. Initially, when ziconotide was first administered to human subjects, titration schedules were overly aggressive and led to an abundance of adverse effects. Subsequently, clinicians have gained appreciation for ziconotide’s relatively narrow therapeutic window. With appropriate usage multiple studies have shown ziconotide to be a safe and effective intrathecal analgesic alone or in combination with other intrathecal analgesics.Keywords: pain, ziconotide, intrathecal analgesics, safety, patient

  4. Evaluation of Postoperative Anti-nociceptive Efficacy of Intrathecal Dexketoprofen in Rats

    Directory of Open Access Journals (Sweden)

    Birol Muhammet Er

    2016-06-01

    Full Text Available Background: Some studies have suggested that the intrathecal use of cyclooxygenase enzyme inhibitors provides an anti-nociceptive effect. Therefore, the occurrence of side effects seen in systemic usage can be eliminated. Aims: The primary objective of this experimental, randomized, controlled trial was to test the hypothesis asserting that intrathecal dexketoprofen trometamol would demonstrate an analgesic effect during postoperative period. Study Design: Animal experimentation. Methods: Forty rats were randomized into 4 groups 7 days after intrathecal catheterization; the following drugs were given through catheter lumens: Group Lidocaine (Group L: Lidocaine 20 μg; Group Lidocaine-Morphine (Group LM: Lidocaine 20 μg and morphine 0.5 μgr; Group Lidocaine-Dexketoprofen (Group LD: Lidocaine 20 μg and dexketoprofen trometamol 100 μg; and Group Dexketoprofen (Group D: Dexketoprofen trometamol 100 μg. Paw incision was achieved under ether inhalation. To measure analgesic potential, hot plate and tail immersion tests were used as nociceptive tests during the postoperative period. Results: The mean reaction times detected in groups during hot plate and tail immersion tests were shortest in Group L at 15, 30, 45, 60, 75, 90, 105, and 120 minutes after start of surgery (p<0.01, all others. In the groups using dexketoprofen, as in the morphine group, longer reaction times were detected than in the lidocaine group at all measurement times except 120 minutes (p<0.01. Conclusion: Intrathecal dexketoprofen in the optimal perioperative pain management is effective, and can be administered as an adjuvant in clinics after neurotoxicity studies in animals, and effective dose studies in volunteers.

  5. The antinociceptive effects of Monechma ciliatum and changes in EEG waves following oral and intrathecal administration in rats

    Science.gov (United States)

    Meraiyebu, Ajibola B.; Adelaiye, Alexander B.; O, Odeh S.

    2010-02-01

    The research work was carried out to study the effect of Oral and Intrathecal Monechma Ciliatum on antinociception and EEG readings in Wistar Rats. Traditionally the extract is given to women in labour believed to reduce pain and ease parturition, though past works show that it has oesteogenic and oxytotic effects. The rats were divided into 5 major groups. Group 1 served as oral control group while groups 2 and 3 served as oral experimental groups and were treated with 500mg/kg and 1000mg/kg monechma ciliatum respectively. Group 4 served as intrathecal control group treated with intrathecal dextrose and group 5 received 1000mg/kg Monechma Ciliatrum intrathecally. The antinociceptive effect was analysed using a Von Frey's aesthesiometer. Monechma Ciliatum showed significant antinociceptive effect both orally and intrathecally, although it had a greater effect orally and during the first 15 minutes of intrathecal administration. EEG readings were also taken for all the groups and there was a decrease in amplitude and an increase in frequency for high dose (1000mg/ml) experimental groups and the mid brain electrodes produced a change from theta waves (3.5 - 7 waves per second) to alpha waves (7.5 - 13 waves per second) as seen in relaxed persons and caused decreased amplitudes and change in distribution seen in beta waves. Properties similarly accentuated by sedativehypnotic drugs.

  6. Antinociceptive Effect of Intrathecal Microencapsulated Human Pheochromocytoma Cell in a Rat Model of Bone Cancer Pain

    Directory of Open Access Journals (Sweden)

    Xiao Li

    2014-07-01

    Full Text Available Human pheochromocytoma cells, which are demonstrated to contain and release met-enkephalin and norepinephrine, may be a promising resource for cell therapy in cancer-induced intractable pain. Intrathecal injection of alginate-poly (l lysine-alginate (APA microencapsulated human pheochromocytoma cells leads to antinociceptive effect in a rat model of bone cancer pain, and this effect was blocked by opioid antagonist naloxone and alpha 2-adrenergic antagonist rauwolscine. Neurochemical changes of cerebrospinal fluid are in accordance with the analgesic responses. Taken together, these data support that human pheochromocytoma cell implant-induced antinociception was mediated by met-enkephalin and norepinephrine secreted from the cell implants and acting at spinal receptors. Spinal implantation of microencapsulated human pheochromocytoma cells may provide an alternative approach for the therapy of chronic intractable pain.

  7. Treatment of severe spacticity in multiple sclerosis by continuous intrathecal baclofen

    Directory of Open Access Journals (Sweden)

    Perić Predrag

    2006-01-01

    Full Text Available Background. Successful treatment of severe spasticity represents an imperative of symptomatic therapy of multiple sclerosis (MS due to a significant improvement of physical, psychic and social rehabilitation of MS patients, as well as a longterm cost savings for the additional treatments of conditions arising from uncontrolled severe spasticity. Continuous intrathecal administration of baclofen (ITB, using a subcutaneously implanted programmable infusion pump, is a minimally invasive, reversible method for the treatment of severe diffuse spasticity of the spinal origin. Case report. The first two cases in our country, treated by ITB due to severe spasticity caused by MS, were reported. Despite the local complications of surgical wound healing above the implanted components of the ITB-system in one patient, the optimal reduction of spasticity the with complete elimination of spastic pain was obtained in both patients. Conclusion. Our initial experiences confirmed ITB as a safe and effective therapeutical option for the treatment of intractable spasticity in patients with MS. Major prerequisites for this were adequate patient selection and good control of the basic disease. The use of the minimal invasive implantation technique and the experience in choosing of the adequate ITB-system components, could successfully prevent the occurrence of local complications related to the impaired healing of the ITB-system implantation site.

  8. Intrathecal analgesia and palliative care: A case study

    Directory of Open Access Journals (Sweden)

    Naveen S Salins

    2010-01-01

    Full Text Available Intrathecal analgesia is an interventional form of pain relief with definite advantages and multiple complications. Administration of intrathecal analgesia needs a good resource setting and expertise. Early complications of intrathecal analgesia can be very distressing and managing these complications will need a high degree of knowledge, technical expertise and level of experience. Pain control alone cannot be the marker of quality in palliative care. A holistic approach may need to be employed that is more person and family oriented.

  9. Resolution of chronic migraine headaches with intrathecal ziconotide: a case report

    Directory of Open Access Journals (Sweden)

    Narain S

    2015-09-01

    Full Text Available Sachin Narain,1 Lama Al-Khoury,2 Eric Chang3–6 1Department of Anesthesiology and Perioperative Care, 2Department of Neurology, 3Department of Physical Medicine and Rehabilitation, 4Department of Neurosurgery, 5Department of Orthopedics, 6Reeve-Irvine Research Center for Spinal Cord Injury, University of California Irvine, Irvine, CA, USA Background: Migraine headaches are a common and functionally debilitating disorder affecting approximately 17% of women and 5.6% of men. Compared to episodic migraine patients, chronic migraineurs are more likely to be occupationally disabled, miss family activities, have comorbid anxiety and/or chronic pain disorders, and utilize significantly more health care dollars. Ziconotide is a calcium channel blocker used for the treatment of chronic severe pain without issues of tolerance or dependency found with opioid therapy. Case: A 59-year-old female had an intrathecal baclofen pump placed for spasticity secondary to multiple sclerosis. Her symptoms also included lower extremity neuropathic pain and severe migraine headaches with 22 migraine headache days per month. Prior treatments included nonsteroidal anti-inflammatory drugs, triptans, anticonvulsants, antihypertensives, and Botox injections which reduced her symptoms to four migraine days per month at best. While her spasticity had markedly improved with intrathecal baclofen, ziconotide was added to help her neuropathic pain complaints. Following initiation of low-dose ziconotide (1 µg/day, the patient noted both lower extremity pain improvement and complete resolution of migraine headaches resulting in zero migraine days per month. She has now been migraine free for 8 months. Conclusion: Upon review of the available literature, there are no published cases of migraine improvement with intrathecal ziconotide. This represents the first case describing resolution of migraine symptoms with low-dose ziconotide. Keywords: ziconotide, migraine, symptoms, chronic

  10. Intrathecal hypobaric versus hyperbaric bupivacaine with morphine for cesarean section.

    Science.gov (United States)

    Richardson, M G; Collins, H V; Wissler, R N

    1998-08-01

    Both hyper- and hypobaric solutions of bupivacaine are often combined with morphine to provide subarachnoid anesthesia for cesarean section. Differences in the baricity of subarachnoid solutions influence the intrathecal distribution of anesthetic drugs and would be expected to influence measurable clinical variables. We compared the effects of hyper- and hypobaric subarachnoid bupivacaine with morphine to determine whether one has significant advantages with regard to intraoperative anesthesia and postoperative analgesia in term parturients undergoing elective cesarean section. Thirty parturients were randomized to receive either hyper- or hypobaric bupivacaine (15 mg) with morphine sulfate (0.2 mg). Intraoperative outcomes compared included extent of sensory block, quality of anesthesia, and side effects. Postoperative outcomes, including pain visual analog scale scores, systemic analgesic requirements, and side effects, were monitored for 48 h. Sedation effects were quantified and compared using Trieger and digit-symbol substitution tests. We detected no differences in sensory or motor block, quality of anesthesia, quality of postoperative analgesia, incidence of side effects, or psychometric scores. Both preparations provide highly satisfactory anesthesia for cesarean section and effective postoperative analgesia. Dextrose alters the density of intrathecal bupivacaine solutions and is thought to influence subarachnoid distribution of the drug. We randomized parturients undergoing cesarean section to one of two often used spinal bupivacaine preparations, hypobaric and hyperbaric. We detected no differences in clinical outcomes between groups.

  11. Intrathecal opioids versus epidural local anesthetics for labor analgesia: a meta-analysis.

    Science.gov (United States)

    Bucklin, Brenda A; Chestnut, David H; Hawkins, Joy L

    2002-01-01

    Some anesthesiologists contend that intrathecal opioid administration has advantages over conventional epidural techniques during labor. Randomized clinical trials comparing analgesia and obstetric outcome using single-injection intrathecal opioids versus epidural local anesthetics suggest that intrathecal opioids provide comparable analgesia with few serious side effects. This meta-analysis compared the analgesic efficacy, side effects, and obstetric outcome of single-injection intrathecal opioid techniques versus epidural local anesthetics in laboring women. Relevant clinical studies were identified using electronic and manual searches of the literature covering the period from 1989 to 2000. Searches used the following descriptors: intrathecal analgesia, spinal opioids, epidural analgesia, epidural local anesthetics, and analgesia for labor. Data were extracted from 7 randomized clinical trials comparing analgesic measures, incidence of motor block, pruritus, nausea, hypotension, mode of delivery, and/or Apgar scores. Combined test results indicated comparable analgesic efficacy 15 to 20 minutes after injection with single-injection intrathecal opioid administration. Intrathecal opioid injections were associated with a greater incidence of pruritus (odds ratio, 14.01; 99% confidence interval, 6.9 to 28.3), but there was no difference in the incidence of nausea or in the method of delivery. Published studies suggest that intrathecal opioids provide comparable early labor analgesia when compared with epidural local anesthetics. Intrathecal opioid administration results in a greater incidence of pruritus. The choice of technique does not appear to affect the method of delivery.

  12. Efficacy of intrathecal baclofen delivery in the management of severe spasticity in upper motor neuron syndrome

    NARCIS (Netherlands)

    Rietman, Johan Swanik; Geertzen, J.H.B.

    In the treatment of patients with severe spasticity, intrathecal administration of baclofen (ITB) was introduced in order to exert its effect directly at the receptor sites in the spinal cord, and have better therapeutic efficacy with smaller drug doses compared to oral antispasmodic medications.

  13. Historical spirals of intrathecal therapy of bacterial meningoencephalites: from past to present

    Directory of Open Access Journals (Sweden)

    Сергей Петрович Борщев

    2015-10-01

    Full Text Available On the base of studying medical literature in the article was considered the history of using intrathecal methods of bacterial meningoencephalites therapy, using intrathecal methods in other medical fields, the modern state of problem.Aim of research: To study the history of using intrathecal methods of bacterial meningoencephalites therapy, the state of problem in the world, an experience of using intrathecal therapeutical methods in other medical fields and to define prospects and necessity of further scientific researches in this direction.Materials and methods: There were used scientometric data bases, available scientific medical printing editions, historical, analytical, philosophical methods, analysis and generalization, the cause-and-effect relations, logic, dialectic.Results of research: There were revealed regularities of growth and decline of interest of medical community to this problem. For today there is no unambiguous attitude to intrathecal therapy of bacterial meningoencephalites. There are contrary opinions about necessity of using this method. There were revealed objective factors that complicate the development of researches in the field of intrathecal therapy of bacterial meningoencephalites.Conclusions: 1. Intrathecal methods of administration preparations at treating patients with bacterial meningoencephalites were successfully used from the beginning of 20 century.2. The degree of interest of medical scientific community to intrathecal therapeutical methods depended on objective necessity of its use in different medical fields at the concrete historical stage.3. Attention to intrathecal methods of treatment decreased as an effect of discovery new antibacterial preparations4. From historical point of view the spread of intrathecal methods of treatment depends on toxicity and effectiveness of preparations for the system use: the higher toxicity and less effectiveness of the system therapy, the more spread use of intrathecal

  14. Evaluation of Postoperative Anti-nociceptive Efficacy of Intrathecal Dexketoprofen in Rats.

    Science.gov (United States)

    Birol Muhammet, Er; Kocamanoğlu, İsmail Serhat; Bozkurt, Ayhan; Bilge, Sırrı; Çetinoğlu, Erhan Çetin

    2016-05-01

    Some studies have suggested that the intrathecal use of cyclooxygenase enzyme inhibitors provides an anti-nociceptive effect. Therefore, the occurrence of side effects seen in systemic usage can be eliminated. The primary objective of this experimental, randomized, controlled trial was to test the hypothesis asserting that intrathecal dexketoprofen trometamol would demonstrate an analgesic effect during postoperative period. Animal experimentation. Forty rats were randomized into 4 groups 7 days after intrathecal catheterization; the following drugs were given through catheter lumens: Group Lidocaine (Group L): Lidocaine 20 μg; Group Lidocaine-Morphine (Group LM): Lidocaine 20 μg and morphine 0.5 μgr; Group Lidocaine-Dexketoprofen (Group LD): Lidocaine 20 μg and dexketoprofen trometamol 100 μg; and Group Dexketoprofen (Group D): Dexketoprofen trometamol 100 μg. Paw incision was achieved under ether inhalation. To measure analgesic potential, hot plate and tail immersion tests were used as nociceptive tests during the postoperative period. The mean reaction times detected in groups during hot plate and tail immersion tests were shortest in Group L at 15, 30, 45, 60, 75, 90, 105, and 120 minutes after start of surgery (pdexketoprofen, as in the morphine group, longer reaction times were detected than in the lidocaine group at all measurement times except 120 minutes (pdexketoprofen in the optimal perioperative pain management is effective, and can be administered as an adjuvant in clinics after neurotoxicity studies in animals, and effective dose studies in volunteers.

  15. Histologic Assessment of Drug-Eluting Grafts Related to Implantation Site

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Tille

    2016-02-01

    Full Text Available Drug-eluting vascular prostheses represent a new direction in vascular surgery to reduce early thrombosis and late intimal hyperplasia for small calibre grafts. Subcutaneous implantation in rats is a rapid and cost-effective screening model to assess the drug-elution effect and could, to some extent, be useful to forecast results for vascular prostheses. We compared biological and histological responses to scaffolds in different implantation sites. Polycaprolactone (PCL, paclitaxel-loaded PCL (PCL-PTX and dexamethasone-loaded PCL (PCL-DXM electrospun scaffolds were implanted subcutaneously and in an infrarenal abdominal aortic model in rats for up to 12 weeks. At the conclusion of the study, a histological analysis was performed. Cellular graft invasion revealed differences in the progression of cellular infiltration between PCL-PTX and PCL/PCL-DXM groups in both models. Cell infiltration increased over time in the aortic model compared to the subcutaneous model for all groups. Cell counting revealed major differences in fibroblast, macrophage and giant cell graft colonisation in all groups and models over time. Macrophages and giant cells increased in the PCL aortic model; whereas in the subcutaneous model these cell types increased only after three weeks or even decreased in the drug-eluting PCL groups. Other major findings were observed only in the aortic replacement such as extracellular matrix deposition and neo-angiogenesis. The subcutaneous implant model can be used for screening, especially when drug-eluting effects are studied. However, major histological differences were observed in cell type reaction and depth of cell penetration compared to the aortic model. Our results demonstrate that the implantation site is a critical determinant of the biological response.

  16. Efficacy of intravenous plus intrathecal/intracerebral ventricle injection of polymyxin B for post-neurosurgical intracranial infections due to MDR/XDR Acinectobacter baumannii: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Sijun Pan

    2018-01-01

    Full Text Available Abstract Background Post-neurosurgical intracranial infections caused by multidrug-resistant or extensively drug-resistant Acinetobacter baumannii are difficult to treat and associated with high mortality. In this study, we analyzed the therapeutic efficacy of intravenous combined with intrathecal/intracerebral ventricle injection of polymyxin B for this type of intracranial infection. Methods This retrospective study was conducted from January 2013 to September 2017 at the Second Affiliated Hospital, Zhejiang University School of Medicine (Hangzhou,China and included 61 cases for which cerebrospinal fluid (CSF cultures were positive for multidrug-resistant or extensively drug-resistant A. baumannii after a neurosurgical operation. Patients treated with intravenous and intrathecal/intracerebral ventricle injection of polymyxin B were assigned to the intrathecal/intracerebral group, and patients treated with other antibiotics without intrathecal/intracerebral injection were assigned to the intravenous group. Data for general information, treatment history, and the results of routine tests and biochemistry indicators in CSF, clinical efficiency, microbiological clearance rate, and the 28-day mortality were collected and analyzed. Results The rate of multidrug-resistant or extensively drug-resistant A. baumannii infection among patients who experienced an intracranial infection after a neurosurgical operation was 33.64% in our hospital. The isolated A. baumannii were resistant to various antibiotics, and most seriously to carbapenems (100.00% resistance rate to imipenem and meropenem, cephalosporins (resistance rates of 98.38% to cefazolin, 100.00% to ceftazidime, 100.00% to cefatriaxone, and 98.39% to cefepime. However, the isolated A. baumannii were completely sensitive to polymyxin B (sensitivity rate of 100.00%, followed by tigecycline (60.66% and amikacin (49.18%. No significant differences in basic clinical data were observed between the two

  17. Retrospective analysis of the financial break-even point for intrathecal morphine pump use in Korea.

    Science.gov (United States)

    Kim, Eun Kyoung; Shin, Ji Yeon; Castañeda, Anyela Marcela; Lee, Seung Jae; Yoon, Hyun Kyu; Kim, Yong Chul; Moon, Jee Youn

    2017-10-01

    The high cost of intrathecal morphine pump (ITMP) implantation may be the main obstacle to its use. Since July 2014, the Korean national health insurance (NHI) program began paying 50% of the ITMP implantation cost in select refractory chronic pain patients. The aims of this study were to investigate the financial break-even point and patients' satisfaction in patients with ITMP treatment after the initiation of the NHI reimbursement. We collected data retrospectively or via direct phone calls to patients who underwent ITMP implantation at a single university-based tertiary hospital between July 2014 and May 2016. Pain severity, changes in the morphine equivalent daily dosage (MEDD), any adverse events, and patients' satisfaction were determined. We calculated the financial break-even point of ITMP implantation via investigating the patient's actual medical costs and insurance information. During the studied period, 23 patients received ITMP implantation, and 20 patients were included in our study. Scores on an 11-point numeric rating scale (NRS) for pain were significantly reduced compared to the baseline value ( P break-even point was 28 months for ITMP treatment after the NHI reimbursement policy. ITMP provided effective chronic pain management with improved satisfaction and reasonable financial break-even point of 28 months with 50% financial coverage by NHI program.

  18. Comparison of the pharmacokinetics of imipenem after intravenous and intrathecal administration in rabbits.

    Science.gov (United States)

    Wang, Y; Qiu, L; Dong, J; Wang, B; Shi, Z; Liu, B; Wang, W; Zhang, J; Cai, S; Ye, G; Cai, X

    2013-03-01

    Intrathecal administration of antibiotics has potentially high effectiveness for the treatment for severe intracranial infections, particularly nosocomial meningitis. The use of intrathecal injection of antibiotics has been reported mostly in case reports. However, there is sparse data regarding the pharmacokinetics of antibiotics after intrathecal administration. This study investigated whether intrathecal injection is an effective method for the administration of imipenem. The pharmacokinetics of imipenem after intrathecal and intravenous administration of 1:1 imipenem: cilastatin (IMI/CIL) to rabbits were compared. The AUC0-t in the cerebrospinal fluid for intrathecal administration was approximately twice that of an equal dose of intravenous administration at doses of 0.35, 0.7, and 1.4 mg/kg. Brain concentrations of imipenem after intrathecal injection were three times greater than observed after intravenous injection and remained high for at least 8 hours post-injection. Elimination of imipenem after administration by either route was primarily via urine, but a transient surge of imipenem in bile and intestinal tissue was observed. Results indicate that there is a clinical potential for intrathecally administered IMI/CIL. Further studies are warranted to investigate the potential for seizure and to assess the translatability of the rabbit model to human treatment.

  19. Clopidogrel discontinuation within the first year after coronary drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Thim, Troels; Johansen, Martin Berg; Chisholm, Gro Egholm

    2014-01-01

    BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug-eluting ......BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug......-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. RESULTS: Discontinuation of clopidogrel within the first 3 months after...... stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were...

  20. Aneurysm, arachnoiditis and intrathecal Au (gold)

    International Nuclear Information System (INIS)

    Pence, D.M.; Kim, T.H.; Levitt, S.H.

    1990-01-01

    This report is a 20-year follow-up of 14 patients treated with external beam craniospinal irradiation and intrathecal gold (10-45 mCi) for medulloblastoma. Six of the patients died within 2 years of treatment from persistent disease. No patients are alive without complications. Six of eight surviving patients developed arachnoiditis and cauda equina syndrome within 5 to 10 years of treatment. Seven of eight survivors developed aneurysms and/or cerebrovascular accidents 9 to 20 years after treatment. Four of the cerebrovascular events were fatal. Intrathecal gold pools in the basal cisterns and cauda equina delivering an extremely inhomogeneous dose throughout the neuroaxis. Its use is discouraged

  1. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  2. Bupivacaine administered intrathecally versus rectally in the management of intractable rectal cancer pain in palliative care

    Directory of Open Access Journals (Sweden)

    Zaporowska-Stachowiak I

    2014-10-01

    Full Text Available Iwona Zaporowska-Stachowiak,1,2 Grzegorz Kowalski,3 Jacek Łuczak,2 Katarzyna Kosicka,4 Aleksandra Kotlinska-Lemieszek,3 Maciej Sopata,3 Franciszek Główka4 1Chair and Department of Pharmacology, Poznan University of Medical Sciences, Poznan, Poland; 2Palliative Medicine In-patient Unit, University Hospital of Lord's Transfiguration, Poznan University of Medical Sciences, Poznan, Poland; 3Palliative Medicine Chair and Department, Poznan University of Medical Sciences, Poznan, Poland; 4Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, Poznan, Poland Background: Unacceptable adverse effects, contraindications to and/or ineffectiveness of World Health Organization step III "pain ladder" drugs causes needless suffering among a population of cancer patients. Successful management of severe cancer pain may require invasive treatment. However, a patient's refusal of an invasive procedure necessitates that clinicians consider alternative options. Objective: Intrathecal bupivacaine delivery as a viable treatment of intractable pain is well documented. There are no data on rectal bupivacaine use in cancer patients or in the treatment of cancer tenesmoid pain. This study aims to demonstrate that bupivacaine administered rectally could be a step in between the current treatment options for intractable cancer pain (conventional/conservative analgesia or invasive procedures, and to evaluate the effect of the mode of administration (intrathecal versus rectal on the bupivacaine plasma concentration.Cases: We present two Caucasian, elderly inpatients admitted to hospice due to intractable rectal/tenesmoid pain. The first case is a female with vulvar cancer, and malignant infiltration of the rectum/vagina. Bupivacaine was used intrathecally (0.25–0.5%, 1–2 mL every 6 hours. The second case is a female with ovarian cancer and malignant rectal infiltration. Bupivacaine was adminstered rectally (0.05–0.1%, 100 m

  3. Chronopharmacodynamics of Intrathecal Co-injection of Sufentanyl and Bupivacaine in Orthopedic Surgery of Lower Extremities

    Directory of Open Access Journals (Sweden)

    B Sadri

    2012-05-01

    Full Text Available  

    Background and objectives: In chronopharmacology the biological rhythm variations caused by drug administration is assessed. Evaluation of the time of drug administration and the qualitative and quantitative effects of reactions to drugs is called chronopharmacodynamics. In this study, we assessed the chronopharmacodynamics of intrathecal co-administration of sufentanyl and bupivacaine in surgical operations of lower extremities.  

    Methods: In 2006, patients aged 20-50 with ASA physical status of I and II, who underwent surgical operation of lower extremities were entered into this prospective study. The patients received a slow intrathecal injection of 10 μg sufentanyl and 15 mg bupivacaine into subarachnoid of third and fourth lumbar spaces in 30 seconds. After the operation, the time of first pain sensation and the visual analogue scale (VAS score, as the measure of severity of pain, were recorded.  

    Results: 115 patients were studied in this project. The pain-free interval was considered as the time between injection and patient’s demand for pain relief. This interval was 746 (± 322 minutes. The average score of pain severity on VAS at the time of demand for pain relief was 24.7 (± 9.3. The average pain-free duration in patients injected about noon or at midnight was significantly longer than the pain-free interval of other patients. 

    Conclusion: The results show that intrathecal co-administration of sufentanyl and bupivacaine at noon or midnight (conforming to the circadian rhythm causes better pain-relief with longer duration in comparison with other times of the day or night. 

  4. Labour analgesia with intrathecal fentanyl decreases maternal stress.

    Science.gov (United States)

    Cascio, M; Pygon, B; Bernett, C; Ramanathan, S

    1997-06-01

    Lumbar epidural analgesia (LEA) decreases maternal stress as measured by maternal circulating plasma catecholamine concentrations. Intrathecal fentanyl (ITF) provides effective labour analgesia but its effect on maternal epinephrine (Epi) and norepinephrine (NE) concentrations is not known. This study assesses whether ITF reduces maternal stress in the same manner as conventional LEA. Twenty-four healthy women in active labour received either 25 micrograms ITF (n = 12) or epidural lidocaine 1.5% (n = 12) for analgesia. Venous blood samples were collected before anaesthesia and at five minute intervals for 30 min following anaesthesia for the measurement of plasma Epi and NE by high performance liquid chromatography. Maternal blood pressure (BP), heart rate (HR), visual analog scores (VAS) to pain and pruritus were recorded at the same time. Both ITF and LEA decreased pain VAS scores, maternal BP, and plasma Epi concentrations with only minimal effects on plasma NE concentrations. Intrathecal fentanyl (ITF) and LEA reduced plasma epi to a similar extent, with ITF reducing the levels slightly faster than LEA. Intrathecal fentanyl(ITF) and LEA reduced plasma Epi concentrations by 52% and 51%, respectively (P value < 0.01). We conclude that ITF is as effective as LEA in producing pain relief in the labouring patient. Intrathecal Fentanyl (ITF) is also capable of reducing maternal plasma epinephrine concentration, thus avoiding the possibly deleterious side effects of excess amounts of this catecholamine during labour.

  5. Intracranial Stent Implantation for Drug Resistant Atherosclerotic Stenosis: Results of 52 Cases

    International Nuclear Information System (INIS)

    Kim, Kuk Seon; Hwang, Dae Hyun; Ko, Young Hwan; Kang, Ik Won; Lee, Eil Seong; Han, You Mie; Kim, In Soo; Hur, Choon Woong

    2011-01-01

    We evaluated the usefulness of intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses. Between March 2004 and July 2007, we tried intracranial stent implantation in 49 patients with 52 lesions (anterior circulation 48 cases, posterior circulation 4 cases) who had an ischemic stroke with more than 50% of major cerebral artery stenosis. We classified the lesions by their location and morphology, analyzed the results in terms of the success rate, complication rate, and restenosis rate during the follow-up period. Intracranial stent implantation was performed successfully in 43 cases (82.7%). In eight of the nine cases, the stent implantation failure was due to the tortuosity of the target vessel. There was no major periprocedural complication. One patient showed cerebellar infarction after the procedure. Mean residual stenoses decreased from 70.2% to 13.0%. Four cases (9.3%) demonstrated in-stent restenoses and more than 50% during the mean and 25.3/month after the follow-up period. Success rate of intracranial stent implantation may improve on developing technique and more experience. Low rate of complication and restenosis suggest that we can consider intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses.

  6. Efficacy of intravenous plus intrathecal/intracerebral ventricle injection of polymyxin B for post-neurosurgical intracranial infections due to MDR/XDR Acinectobacter baumannii: a retrospective cohort study.

    Science.gov (United States)

    Pan, Sijun; Huang, Xiaofang; Wang, Yesong; Li, Li; Zhao, Changyun; Yao, Zhongxiang; Cui, Wei; Zhang, Gensheng

    2018-01-01

    Post-neurosurgical intracranial infections caused by multidrug-resistant or extensively drug-resistant Acinetobacter baumannii are difficult to treat and associated with high mortality. In this study, we analyzed the therapeutic efficacy of intravenous combined with intrathecal/intracerebral ventricle injection of polymyxin B for this type of intracranial infection. This retrospective study was conducted from January 2013 to September 2017 at the Second Affiliated Hospital, Zhejiang University School of Medicine (Hangzhou,China) and included 61 cases for which cerebrospinal fluid (CSF) cultures were positive for multidrug-resistant or extensively drug-resistant A. baumannii after a neurosurgical operation. Patients treated with intravenous and intrathecal/intracerebral ventricle injection of polymyxin B were assigned to the intrathecal/intracerebral group, and patients treated with other antibiotics without intrathecal/intracerebral injection were assigned to the intravenous group. Data for general information, treatment history, and the results of routine tests and biochemistry indicators in CSF, clinical efficiency, microbiological clearance rate, and the 28-day mortality were collected and analyzed. The rate of multidrug-resistant or extensively drug-resistant A. baumannii infection among patients who experienced an intracranial infection after a neurosurgical operation was 33.64% in our hospital. The isolated A. baumannii were resistant to various antibiotics, and most seriously to carbapenems (100.00% resistance rate to imipenem and meropenem), cephalosporins (resistance rates of 98.38% to cefazolin, 100.00% to ceftazidime, 100.00% to cefatriaxone, and 98.39% to cefepime). However, the isolated A. baumannii were completely sensitive to polymyxin B (sensitivity rate of 100.00%), followed by tigecycline (60.66%) and amikacin (49.18%). No significant differences in basic clinical data were observed between the two groups. Compared with the intravenous group, the

  7. Transdermal nitroglycerine enhances postoperative analgesia of intrathecal neostigmine following abdominal hysterectomies

    Directory of Open Access Journals (Sweden)

    Fareed Ahmed

    2010-01-01

    Full Text Available This study was carried out to assess the effect of nitroglycerine (transdermal on intrathecal neostigmine with bupivacaine on postoperative analgesia and note the incidence of adverse effects, if any. After taking informed consent, 120 patients of ASA Grade I and II were systematically randomised into four groups of 30 each. Patients were premedicated with midazolam 0.05 mg/kg intravenously and hydration with Ringer′s lactate solution 10ml/kg preoperatively in the holding room. Group I patients received Intrathecal injection of 15 mg bupivacaine with 1ml of normal saline and transdermal placebo patch. Group II patients received Intrathecal injection of 15 mg bupivacaine with 5 mcg of neostigmine and transdermal placebo patch. Group III patients received Intrathecal injection of 15 mg bupivacaine with 1ml of normal saline with transdermal nitroglycerine patch (5 mg/24 hours. Group IV patients received Intrathecal injection of 15 mg bupivacaine with 5mcg of neostigmine and transdermal nitroglycerine patch (5 mg/24 hours, applied on a non anaesthetised area after 20 minutes. Groups were demographically similar and did not differ in intraoperative characteristics like sensory block, motor block, haemodynamic parameters and SpO 2 . The mean duration of analgesia was 202.17 minutes, 407.20 minutes, 207.53 minutes and 581.63 minutes in control group (I, neostigmine group (II, nitroglycerine group (III and nitroglycerine neostigmine group (IV respectively (P< 0.01. To conclude, our results show that transdermal nitroglycerine itself does not show any analgesic potential but it enhances the analgesic potential of intrathecal neostigmine.

  8. Does the intrathecal propofol have a neuroprotective effect on spinal cord ischemia?

    Science.gov (United States)

    Sahin, Murat; Gullu, Huriye; Peker, Kemal; Sayar, Ilyas; Binici, Orhan; Yildiz, Huseyin

    2015-11-01

    The neuroprotective effects of propofol have been confirmed. However, it remains unclear whether intrathecal administration of propofol exhibits neuroprotective effects on spinal cord ischemia. At 1 hour prior to spinal cord ischemia, propofol (100 and 300 µg) was intrathecally administered in rats with spinal cord ischemia. Propofol pre-treatment greatly improved rat pathological changes and neurological function deficits at 24 hours after spinal cord ischemia. These results suggest that intrathecal administration of propofol exhibits neuroprotective effects on spinal cord structural and functional damage caused by ischemia.

  9. The effect of posture and baricity on the spread of intrathecal bupivacaine for elective cesarean delivery.

    Science.gov (United States)

    Hallworth, Stephen P; Fernando, Roshan; Columb, Malachy O; Stocks, Gary M

    2005-04-01

    Posture and baricity during induction of spinal anesthesia with intrathecal drugs are believed to be important in determining spread within the cerebrospinal fluid. In this double-blind prospective study, 150 patients undergoing elective cesarean delivery were randomized to receive a hyperbaric, isobaric, or hypobaric intrathecal solution of 10 mg bupivacaine during spinal anesthesia induced in either the sitting or right lateral position. After an intrathecal injection using a combined-spinal technique patients were placed in the supine wedged position. We determined the densities of the three intrathecal solutions from a previously validated formula and measured using a DMA-450 density meter. Data collection included sensory level, motor block, episodes of hypotension, and ephedrine use. Statistical analysis included analysis of variance and Cuzick's trend. In the lateral position, baricity had no effect on the spread of sensory levels for bupivacaine compared to the sitting position, where there was a statistically significant difference in spread with the hypobaric solution producing higher levels of analgesia than the hyperbaric solution (P = 0.002). However, the overall differences in maximal spread only differed by one dermatome, with the hyperbaric solution achieving a median maximum sensory level to T3 compared with T2 for the isobaric and hypobaric solutions. Motor block was significantly (P = 0.029) reduced with increasing baricity and this trend was significant (P = 0.033) for the lateral position only. Hypotension incidence and ephedrine use increased with decreasing baricity (P = 0.003 and 0.004 respectively), with the hypobaric sitting group having the most frequent incidence of hypotension (76%) as well as cervical blocks (24%; P = 0.032).

  10. Ultrasound enhanced release of therapeutics from drug-releasing implants based on titania nanotube arrays.

    Science.gov (United States)

    Aw, Moom Sinn; Losic, Dusan

    2013-02-25

    A non-invasive and external stimulus-driven local drug delivery system (DDS) based on titania nanotube (TNT) arrays loaded with drug encapsulated polymeric micelles as drug carriers and ultrasound generator is described. Ultrasound waves (USW) generated by a pulsating sonication probe (Sonotrode) in phosphate buffered saline (PBS) at pH 7.2 as the medium for transmitting pressure waves, were used to release drug-loaded nano-carriers from the TNT arrays. It was demonstrated that a very rapid release in pulsatile mode can be achieved, controlled by several parameters on the ultrasonic generator. This includes pulse length, time, amplitude and power intensity. By optimization of these parameters, an immediate drug-micelles release of 100% that spans a desirable time of 5-50 min was achieved. It was shown that stimulated release can be generated and reproduced at any time throughout the TNT-Ti implant life, suggesting considerable potential of this approach as a feasible and tunable ultrasound-mediated drug delivery system in situ via drug-releasing implants. It is expected that this concept can be translated from an in vitro to in vivo regime for therapeutic applications using drug-releasing implants in orthopedic and coronary stents. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  11. Does the intrathecal propofol have a neuroprotective effect on spinal cord ischemia?

    Directory of Open Access Journals (Sweden)

    Murat Sahin

    2015-01-01

    Full Text Available The neuroprotective effects of propofol have been confirmed. However, it remains unclear whether intrathecal administration of propofol exhibits neuroprotective effects on spinal cord ischemia. At 1 hour prior to spinal cord ischemia, propofol (100 and 300 µg was intrathecally administered in rats with spinal cord ischemia. Propofol pre-treatment greatly improved rat pathological changes and neurological function deficits at 24 hours after spinal cord ischemia. These results suggest that intrathecal administration of propofol exhibits neuroprotective effects on spinal cord structural and functional damage caused by ischemia.

  12. Extensive scarring induced by chronic intrathecal tubing augmented cord tissue damage and worsened functional recovery after rat spinal cord injury.

    Science.gov (United States)

    Zhang, Shu-xin; Huang, Fengfa; Gates, Mary; White, Jason; Holmberg, Eric G

    2010-08-30

    Intrathecal infusion has been widely used to directly deliver drugs or neurotrophins to a lesion site following spinal cord injury. Evidence shows that intrathecal infusion is efficient for 7 days but is markedly reduced after 14 days, due to time dependent occlusion. In addition, extensive fibrotic scarring is commonly observed with intrathecal infusion. These anomalies need to be clearly elucidated in histology. In the present study, all adult Long-Evans rats received a 25 mm contusion injury on spinal cord T10 produced using the NYU impactor device. Immediately after injury, catheter tubing with an outer diameter of 0.38 mm was inserted through a small dural opening at L3 into the subdural space with the tubing tip positioned near the injury site. The tubing was connected to an Alzet mini pump, which was filled with saline solution and was placed subcutaneously. Injured rats without tubing served as control. Rats were behaviorally tested for 6 weeks using the BBB locomotor rating scale and histologically assessed for tissue scarring. Six weeks later, we found that the intrathecal tubing caused extensive scarring and inflammation, related to neutrophils, macrophages and plasma cells. The tubing's tip was occluded by scar tissue and inflammatory cells. The scar tissue surrounding the tubing consists of 20-70 layers of fibroblasts and densely compacted collagen fibers, seriously compressing and damaging the cord tissue. BBB scores of rats with intrathecal tubing were significantly lower than control rats (p<0.01) from 2 weeks after injury, implying serious impairment of functional recovery caused by the scarring. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  13. Effects of amphiphilic chitosan-g-poly(ε-caprolactone) polymer additives on paclitaxel release from drug eluting implants

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Weibin [Department of General Surgery, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200092 (China); Gu, Chunhua [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237 (China); Jiang, Han [Department of General Surgery, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200092 (China); Zhang, Mengru [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237 (China); Lang, Meidong, E-mail: mdlang@ecust.edu.cn [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237 (China)

    2014-12-01

    Bioresorbable polymer stents have been proposed as promising medical implants to avoid long-term safety concerns and other potential issues caused by traditional materials. As an important member, poly(ε-caprolactone) (PCL) was used as the implant matrix with different drug loadings. To better regulate drug release rate, the hydrophilicity of PCL was adjusted by addition of amphiphilic graft copolymers, chitosan-g-poly(ε-caprolactone) (CP). The in vitro release results indicated that the improvement of bulk hydrophilicity could accelerate drug release better than that of surface coating. The optimum additive amount was 25% with CP9. Further study showed that the effect of aspirin molecules displayed no obvious difference to that of CP macromolecules on drug release rate. Moreover, these release profiles were fitted with mathematical models. The similarities were evaluated with similarity factors. Scanning electron microscopy (SEM) images displayed surface/cross-section morphologies of pure PCL and modified implants before and after release. - Highlights: • The improvement of bulk hydrophilicity better accelerated drug release. • The higher weight ratio of CP implants had, the faster the drug released. • The shorter PCL chain in CP graft coploymers, the faster the drug released. • The optimum additive amount was 25% with CP9. • Drug release profile conformed to controllable Fick diffusional release mechanism.

  14. Drug-releasing nano-engineered titanium implants: therapeutic efficacy in 3D cell culture model, controlled release and stability

    Energy Technology Data Exchange (ETDEWEB)

    Gulati, Karan [School of Chemical Engineering, The University of Adelaide, SA 5005 (Australia); Kogawa, Masakazu; Prideaux, Matthew; Findlay, David M. [Discipline of Orthopaedics and Trauma, The University of Adelaide, SA 5005 (Australia); Atkins, Gerald J., E-mail: gerald.atkins@adelaide.edu.au [Discipline of Orthopaedics and Trauma, The University of Adelaide, SA 5005 (Australia); Losic, Dusan, E-mail: dusan.losic@adelaide.edu.au [School of Chemical Engineering, The University of Adelaide, SA 5005 (Australia)

    2016-12-01

    There is an ongoing demand for new approaches for treating localized bone pathologies. Here we propose a new strategy for treatment of such conditions, via local delivery of hormones/drugs to the trauma site using drug releasing nano-engineered implants. The proposed implants were prepared in the form of small Ti wires/needles with a nano-engineered oxide layer composed of array of titania nanotubes (TNTs). TNTs implants were inserted into a 3D collagen gel matrix containing human osteoblast-like, and the results confirmed cell migration onto the implants and their attachment and spread. To investigate therapeutic efficacy, TNTs/Ti wires loaded with parathyroid hormone (PTH), an approved anabolic therapeutic for the treatment of severe bone fractures, were inserted into 3D gels containing osteoblast-like cells. Gene expression studies revealed a suppression of SOST (sclerostin) and an increase in RANKL (receptor activator of nuclear factor kappa-B ligand) mRNA expression, confirming the release of PTH from TNTs at concentrations sufficient to alter cell function. The performance of the TNTs wire implants using an example of a drug needed at relatively higher concentrations, the anti-inflammatory drug indomethacin, is also demonstrated. Finally, the mechanical stability of the prepared implants was tested by their insertion into bovine trabecular bone cores ex vivo followed by retrieval, which confirmed the robustness of the TNT structures. This study provides proof of principle for the suitability of the TNT/Ti wire implants for localized bone therapy, which can be customized to cater for specific therapeutic requirements. - Highlights: • Ti wire with titania nanotubes (TNTs) are proposed as ‘in-bone’ therapeutic implants. • 3D cell culture model is used to confirm therapeutic efficacy of drug releasing implants. Osteoblasts migrated and firmly attached to the TNTs and the micro-scale cracks. • Tailorable drug loading from few nanograms to several hundred

  15. Prodigiosin release from an implantable biomedical device: kinetics of localized cancer drug release

    International Nuclear Information System (INIS)

    Danyuo, Y.; Obayemi, J.D.; Dozie-Nwachukwu, S.; Ani, C.J.; Odusanya, O.S.; Oni, Y.; Anuku, N.; Malatesta, K.; Soboyejo, W.O.

    2014-01-01

    This paper presents an implantable encapsulated structure that can deliver localized heating (hyperthermia) and controlled concentrations of prodigiosin (a cancer drug) synthesized by bacteria (Serratia marcesce (subsp. marcescens)). Prototypical Poly-di-methyl-siloxane (PDMS) packages, containing well-controlled micro-channels and drug storage compartments, were fabricated along with a drug-storing polymer produced by free radical polymerization of Poly(N-isopropylacrylamide)(PNIPA) co-monomers of Acrylamide (AM) and Butyl-methacrylate (BMA). The mechanisms of drug diffusion of PNIPA-base gels were elucidated. Scanning Electron Microscopy (SEM) was also used to study the heterogeneous porous structure of the PNIPA-based gels. The release exponents, n, of the gels were found to between 0.5 and 0.7. This is in the range expected for Fickian (n = 0.5). Deviation from Fickian diffusion was also observed (n > 0.5) diffusion. The gel diffusion coefficients were shown to vary between 2.1 × 10 −12 m 2 /s and 4.8 × 10 −6 m 2 /s. The implications of the results are then discussed for the localized treatment of cancer via hyperthermia and the controlled delivery of prodigiosin from encapsulated PNIPA-based devices. - Highlights: • Fabricated thermo-sensitive hydrogels for localized drug release from an implantable biomedical device. • Determined the cancer drug diffusion mechanisms of PNIPA-co-AM copolymer hydrogel. • Encapsulated PNIPA-based hydrogels in PDMS capsules for controlled drug delivery. • Established the kinetics of drug release from gels and channels in an implantable biomedical device. • Demonstrated the potential for the controlled release of prodigiosin (PG) as an anticancer drug

  16. Prodigiosin release from an implantable biomedical device: kinetics of localized cancer drug release

    Energy Technology Data Exchange (ETDEWEB)

    Danyuo, Y.; Obayemi, J.D.; Dozie-Nwachukwu, S. [Department of Materials Science and Engineering, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Ani, C.J. [Department of Theoretical Physics, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Odusanya, O.S. [Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), Abuja, Federal Capital Territory (Nigeria); Oni, Y. [Department of Chemistry, Bronx Community College, New York, NY (United States); Anuku, N. [Department of Chemistry, Bronx Community College, New York, NY (United States); Princeton Institute for the Science and Technology of Materials (PRISM), 70 Prospect Street, Princeton, NJ 08544 (United States); Malatesta, K. [Department of Chemistry, Bronx Community College, New York, NY (United States); Soboyejo, W.O., E-mail: soboyejo@princeton.edu [Department of Materials Science and Engineering, African University of Science and Technology (AUST), Abuja, Federal Capital Territory (Nigeria); Princeton Institute for the Science and Technology of Materials (PRISM), 70 Prospect Street, Princeton, NJ 08544 (United States); Department of Mechanical and Aerospace Engineering 1 Olden Street, Princeton, NJ 08544 (United States)

    2014-09-01

    This paper presents an implantable encapsulated structure that can deliver localized heating (hyperthermia) and controlled concentrations of prodigiosin (a cancer drug) synthesized by bacteria (Serratia marcesce (subsp. marcescens)). Prototypical Poly-di-methyl-siloxane (PDMS) packages, containing well-controlled micro-channels and drug storage compartments, were fabricated along with a drug-storing polymer produced by free radical polymerization of Poly(N-isopropylacrylamide)(PNIPA) co-monomers of Acrylamide (AM) and Butyl-methacrylate (BMA). The mechanisms of drug diffusion of PNIPA-base gels were elucidated. Scanning Electron Microscopy (SEM) was also used to study the heterogeneous porous structure of the PNIPA-based gels. The release exponents, n, of the gels were found to between 0.5 and 0.7. This is in the range expected for Fickian (n = 0.5). Deviation from Fickian diffusion was also observed (n > 0.5) diffusion. The gel diffusion coefficients were shown to vary between 2.1 × 10{sup −12} m{sup 2}/s and 4.8 × 10{sup −6} m{sup 2}/s. The implications of the results are then discussed for the localized treatment of cancer via hyperthermia and the controlled delivery of prodigiosin from encapsulated PNIPA-based devices. - Highlights: • Fabricated thermo-sensitive hydrogels for localized drug release from an implantable biomedical device. • Determined the cancer drug diffusion mechanisms of PNIPA-co-AM copolymer hydrogel. • Encapsulated PNIPA-based hydrogels in PDMS capsules for controlled drug delivery. • Established the kinetics of drug release from gels and channels in an implantable biomedical device. • Demonstrated the potential for the controlled release of prodigiosin (PG) as an anticancer drug.

  17. Effects of intrathecal or intracerebroventricular administration of nonsteroidal anti-inflammatory drugs on a C-fiber reflex in rats.

    Science.gov (United States)

    Bustamante, D; Paeile, C; Willer, J C; Le Bars, D

    1997-06-01

    A C-fiber reflex elicited by electrical stimulation within the territory of the sural nerve was recorded from the ipsilateral biceps femoris muscle in anesthetized rats. The temporal evolution of the response was studied using a constant stimulus intensity (3 times threshold), and recruitment curves were built by varying the stimulus intensity from 0 to 7 times threshold. The intrathecal (i.t.) but not i.c.v. administration of aspirin, indomethacin, ketoprofen and lysine clonixinate resulted in dose-dependent depressions of the C-fiber reflex. In contrast, saline was ineffective. Regardless of the route of administration, the drugs never produced disturbances in heart rate and/or acid-base equilibrium. When a constant level of stimulation was used, 500 microg of aspirin i.t. induced a blockade of the reflex immediately after the injection, followed by a partial recovery. Indomethacin produced a stable depression, which reached 80 to 90% with an i.t. dose of 500 microg. Ketoprofen and lysine clonixinate produced a more stable effect; the highest doses (500 microg) produced a steady-state depression of approximately 50% for approximately 30 min. When the recruitment curves were built with a range of nociceptive stimulus intensities, all of the drugs except for indomethacin produced a dose-dependent decrease in the slopes and the areas under the recruitment curves without major modifications in the thresholds; indomethacin also induced a significant dose-related increase in the threshold. The orders of potency for both stimulation paradigms with the i.t. route were the same, namely aspirin > indomethacin > lysine clonixinate > or = ketoprofen. It is concluded that nonsteroidal anti-inflammatory drugs elicit significant antinociceptive effects at a spinal level, which do not depend on the existence of a hyperalgesic or inflammatory state. Such effects were not seen after injections within the lateral ventricle.

  18. Evaluation of Postoperative Anti-nociceptive Efficacy of Intrathecal Dexketoprofen in Rats

    OpenAIRE

    Birol Muhammet Er; İsmail Serhat Kocamanoğlu; Ayhan Bozkurt; Sırrı Bilge; Erhan Çetin Çetinoğlu

    2016-01-01

    Background: Some studies have suggested that the intrathecal use of cyclooxygenase enzyme inhibitors provides an anti-nociceptive effect. Therefore, the occurrence of side effects seen in systemic usage can be eliminated. Aims: The primary objective of this experimental, randomized, controlled trial was to test the hypothesis asserting that intrathecal dexketoprofen trometamol would demonstrate an analgesic effect during postoperative period. Study Design: Animal experimentation. ...

  19. Design of an Implantable Device for Ocular Drug Delivery

    Directory of Open Access Journals (Sweden)

    Jae-Hwan Lee

    2012-01-01

    Full Text Available Ocular diseases, such as, glaucoma, age-related macular degeneration (AMD, diabetic retinopathy, and retinitis pigmentosa require drug management in order to prevent blindness and affecting million of adults in USA and worldwide. There is an increasing need to develop devices for drug delivery to address ocular diseases. This study focuses on the design, simulation, and development of an implantable ocular drug delivery device consisting of micro-/nanochannels embedded between top and bottom covers with a drug reservoir made from polydimethylsiloxane (PDMS which is silicon-based organic and biodegradable polymer. Several simulations were carried out with six different micro-channel configurations in order to see the feasibility for ocular drug delivery applications. Based on the results obtained, channel design of osmotic I and osmotic II satisfied the diffusion rates required for ocular drug delivery. Finally, a prototype illustrating the three components of the drug delivery design is presented. In the future, the device will be tested for its functionality and diffusion characteristics.

  20. Histologic examination of the rat central nervous system after intrathecal administration of human beta-endorphin

    DEFF Research Database (Denmark)

    Hée, P.; Klinken, Leif; Ballegaard, Martin

    1992-01-01

    Neuropathology, analgesics - intrathecal, central nervous system, histology, human beta-endorphin, toxicity......Neuropathology, analgesics - intrathecal, central nervous system, histology, human beta-endorphin, toxicity...

  1. Intrathecal huperzine A increases thermal escape latency and decreases flinching behavior in the formalin test in rats.

    Science.gov (United States)

    Park, Paula; Schachter, Steven; Yaksh, Tony

    2010-02-05

    Huperzine A (HupA) is an alkaloid isolated from the Chinese club moss Huperzia serrata and has been used for improving memory, cognitive and behavioral function in patients with Alzheimer's disease in China. It has NMDA antagonist and anticholinesterase activity and has shown anticonvulsant and antinociceptive effects in preliminary studies when administered intraperitoneally to mice. To better characterize the antinociceptive effects of HupA at the spinal level, Holtzman rats were implanted with intrathecal catheters to measure thermal escape latency using Hargreaves thermal escape testing system and flinching behavior using the formalin test. Intrathecal (IT) administration of HupA showed a dose-dependent increase in thermal escape latency with an ED50 of 0.57 microg. Atropine reversed the increase in thermal escape latency produced by 10 microg HupA, indicating an antinociceptive mechanism through muscarinic cholinergic receptors. The formalin test showed that HupA decreased flinching behavior in a dose-dependent manner. Atropine also reversed the decrease in flinching behavior caused by 10 microg HupA. A dose-dependent increase of side effects including scratching, biting, and chewing tails was observed, although antinociceptive effects were observed in doses that did not produce any adverse effects. (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  2. Intrathecal immunoglobulin synthesis in patients with symptomatic epilepsy and epilepsy of unknown etiology ('cryptogenic').

    Science.gov (United States)

    Fauser, S; Soellner, C; Bien, C G; Tumani, H

    2017-09-01

    To compare the frequency of intrathecal immunoglobulin (Ig) synthesis in patients with symptomatic epilepsy and epilepsy of unknown etiology ('cryptogenic'). Patients with epileptic (n = 301) and non-epileptic (n = 10) seizures were retrospectively screened for autochthonous intrathecal Ig synthesis and oligoclonal bands (OCBs) in the cerebrospinal fluid. Intrathecal IgG/OCBs were detected in 8% of patients with epilepsies of unknown etiology, 5% of patients with first seizures of unknown cause and 0-4% of patients with epilepsy due to brain tumors, cerebrovascular disease or other etiologies. Intrathecal IgG/OCBs were not seen in patients with psychogenic seizures. Identical OCBs in serum and cerebrospinal fluid were more common in all patient groups (10-40% depending on underlying etiology). Intrathecal IgG synthesis/OCBs were observed slightly more frequently in patients with 'cryptogenic' epilepsy and with first seizures of unknown etiology than in other patient groups. However, this remained an infrequent finding and thus we could not confirm humoral immunity as a leading disease mechanism in patients with epilepsy in general or with unknown etiology in particular. © 2017 EAN.

  3. A programmed release multi-drug implant fabricated by three-dimensional printing technology for bone tuberculosis therapy

    International Nuclear Information System (INIS)

    Wu Weigang; Zheng Qixin; Guo Xiaodong; Sun Jianhua; Liu Yudong

    2009-01-01

    In the world, bone tuberculosis is still very difficult to treat and presents a challenge to clinicians. In this study, we utilized 3D printing technology to fabricate a programmed release multi-drug implant for bone tuberculosis therapy. The construction of the drug implant was a multi-layered concentric cylinder divided into four layers from the center to the periphery. Isoniazid and rifampicin were distributed individually into the different layers in a specific sequence of isoniazid-rifampicin-isoniazid-rifampicin. The drug release assays in vitro and in vivo showed that isoniazid and rifampicin were released orderly from the outside to the center to form the multi-drug therapeutic alliance, and the peak concentrations of drugs were detected in sequence at 8 to 12 day intervals. In addition, no negative effect on the proliferation of rabbit bone marrow mesenchymal stem cells was detected during the cytocompatibility assay. Due to its ideal pharmacologic action and cytocompatibility, the programmed release multi-drug implant with a complex construction fabricated by 3D printing technology could be of interest in prevention and treatment of bone tuberculosis.

  4. A programmed release multi-drug implant fabricated by three-dimensional printing technology for bone tuberculosis therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wu Weigang; Zheng Qixin; Guo Xiaodong; Sun Jianhua; Liu Yudong, E-mail: Zheng-qx@163.co [Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022 (China)

    2009-12-15

    In the world, bone tuberculosis is still very difficult to treat and presents a challenge to clinicians. In this study, we utilized 3D printing technology to fabricate a programmed release multi-drug implant for bone tuberculosis therapy. The construction of the drug implant was a multi-layered concentric cylinder divided into four layers from the center to the periphery. Isoniazid and rifampicin were distributed individually into the different layers in a specific sequence of isoniazid-rifampicin-isoniazid-rifampicin. The drug release assays in vitro and in vivo showed that isoniazid and rifampicin were released orderly from the outside to the center to form the multi-drug therapeutic alliance, and the peak concentrations of drugs were detected in sequence at 8 to 12 day intervals. In addition, no negative effect on the proliferation of rabbit bone marrow mesenchymal stem cells was detected during the cytocompatibility assay. Due to its ideal pharmacologic action and cytocompatibility, the programmed release multi-drug implant with a complex construction fabricated by 3D printing technology could be of interest in prevention and treatment of bone tuberculosis.

  5. RELATIVE POTENCIES OF MOTOR BLOCKADE AFTER INTRATHECAL ROPIVACAINE, LEVOBUPIVACAINE AND BUPIVACAINE

    Directory of Open Access Journals (Sweden)

    Udayagiri Ravisankar

    2015-12-01

    Full Text Available AIM Ever since the times spinal anaesthesia has been introduced by August Bier, multiple drugs at different dosages, concentrations and differing baricities have been studied. This study was conducted to compare the anaesthetic efficacy of intrathecal isobaric 0.5% ropivacaine, isobaric 0.5% bupivacaine and isobaric levobupivacaine in lower abdominal and lower limb surgeries, in 150 ASA grade I and II patients of both sexes in the age group of 19-65 years undergoing elective surgery under spinal anaesthesia. MATERIALS & METHODS After getting ethical committee approval and informed written consent from the patients, 150 patients were allocated into three groups of 50 patients each. The baseline pulse rate and mean arterial pressure were recorded. The first group A received 3ml of isobaric 0.5% ropivacaine (5mg/ml, the second group received 3ml of isobaric 0.5% bupivacaine and the third group C received 3ml of isobaric levobupivacaine intrathecally. The onset of sensory and motor blocks, duration of sensory and motor blocks was recorded in three groups. RESULTS The results were analyzed statistically using epidemiologically information package. On comparison of data we have found that the intrathecal isobaric 0.5% ropivacaine produces delayed onset of both sensory and motor block but of shorter duration which is statistically significant when compared with that of isobaric 0.5% bupivacaine and levobupivacaine. There is no significant inter-group difference between bupivacaine and levobupivacaine except for the mean duration of sensory block, which is more in levobupivacaine group. The quality of motor block which was assessed by Bromage scale, shows relatively lesser degree of motor block for ropivacaine group, when compared with that of bupivacaine and levobupivacaine groups. The haemodynamics were also recorded. The incidence of hypotension and Bradycardia is more in bupivacaine group. The height of block (peak sensory level is higher for

  6. Treatment of HER2-positive breast carcinomatous meningitis with intrathecal administration of {alpha}-particle-emitting {sup 211}At-labeled trastuzumab

    Energy Technology Data Exchange (ETDEWEB)

    Boskovitz, Abraham; McLendon, Roger E.; Okamura, Tatsunori [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States); Sampson, John H. [Department of Surgery, Duke University Medical Center, Durham, NC 27710 (United States); Bigner, Darell D. [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States); Zalutsky, Michael R. [Department of Radiology, Duke University Medical Center, Durham, NC 27710 (United States)], E-mail: zalut001@mc.duke.edu

    2009-08-15

    Introduction: Carcinomatous meningitis (CM) is a devastating disease characterized by the dissemination of malignant tumor cells into the subarachnoid space along the brain and spine. Systemic treatment with monoclonal antibody (mAb) trastuzumab can be effective against HER2-positive systemic breast carcinoma but, like other therapies, is ineffective against CM. The goal of this study was to evaluate the therapeutic effect of {alpha}-particle emitting {sup 211}At-labeled trastuzumab following intrathecal administration in a rat model of breast carcinoma CM. Methods: Athymic rats were injected intrathecally with MCF-7/HER2-18 breast carcinoma cells through a surgically implanted indwelling intrathecal catheter. In Experiment 1, animals received 33 or 66 {mu}Ci {sup 211}At-labeled trastuzumab, cold trastuzumab or saline. In Experiment 2, animals were inoculated with a lower tumor burden and received 46 or 92 {mu}Ci {sup 211}At-labeled trastuzumab or saline. In Experiment 3, animals received 28 {mu}Ci {sup 211}At-labeled trastuzumab, 30 {mu}Ci {sup 211}At-labeled TPS3.2 control mAb or saline. Histopathological analysis of the neuroaxis was performed at the end of the study. Results: In Experiment 1, median survival increased from 21 days for the saline and cold trastuzumab groups to 45 and 48 days for 33 and 66 {mu}Ci {sup 211}At-labeled trastuzumab, respectively. In Experiment 2, median survival increased from 23 days for saline controls to 68 and 92 days for 46 and 92 {mu}Ci {sup 211}At-labeled trastuzumab, respectively. In Experiment 3, median survival increased from 20 days to 29 and 36 days for animals treated with {sup 211}At-labeled TPS3.2 and {sup 211}At-labeled trastuzumab, respectively. Long-term survivors were observed exclusively in the {sup 211}At-trastuzumab-treated groups. Conclusion: Intrathecal {sup 211}At-labeled trastuzumab shows promise as a treatment for patients with HER2-positive breast CM.

  7. Dental implants modified with drug releasing titania nanotubes: therapeutic potential and developmental challenges.

    Science.gov (United States)

    Gulati, Karan; Ivanovski, Sašo

    2017-08-01

    The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.

  8. Validation of a preclinical spinal safety model: effects of intrathecal morphine in the neonatal rat.

    Science.gov (United States)

    Westin, B David; Walker, Suellen M; Deumens, Ronald; Grafe, Marjorie; Yaksh, Tony L

    2010-07-01

    Preclinical studies demonstrate increased neuroapoptosis after general anesthesia in early life. Neuraxial techniques may minimize potential risks, but there has been no systematic evaluation of spinal analgesic safety in developmental models. We aimed to validate a preclinical model for evaluating dose-dependent efficacy, spinal cord toxicity, and long-term function after intrathecal morphine in the neonatal rat. Lumbar intrathecal injections were performed in anesthetized rats aged postnatal day (P) 3, 10, and 21. The relationship between injectate volume and segmental spread was assessed postmortem and by in vivo imaging. To determine the antinociceptive dose, mechanical withdrawal thresholds were measured at baseline and 30 min after intrathecal morphine. To evaluate toxicity, doses up to the maximum tolerated were administered, and spinal cord histopathology, apoptosis, and glial response were evaluated 1 and 7 days after P3 or P21 injection. Sensory thresholds and gait analysis were evaluated at P35. Intrathecal injection can be reliably performed at all postnatal ages and injectate volume influences segmental spread. Intrathecal morphine produced spinally mediated analgesia at all ages with lower dose requirements in younger pups. High-dose intrathecal morphine did not produce signs of spinal cord toxicity or alter long-term function. The therapeutic ratio for intrathecal morphine (toxic dose/antinociceptive dose) was at least 300 at P3 and at least 20 at P21 (latter doses limited by side effects). These data provide relative efficacy and safety for comparison with other analgesic preparations and contribute supporting evidence for the validity of this preclinical neonatal safety model.

  9. Near-infrared fluorescence imaging platform for quantifying in vivo nanoparticle diffusion from drug loaded implants.

    Science.gov (United States)

    Markovic, Stacey; Belz, Jodi; Kumar, Rajiv; Cormack, Robert A; Sridhar, Srinivas; Niedre, Mark

    2016-01-01

    Drug loaded implants are a new, versatile technology platform to deliver a localized payload of drugs for various disease models. One example is the implantable nanoplatform for chemo-radiation therapy where inert brachytherapy spacers are replaced by spacers doped with nanoparticles (NPs) loaded with chemotherapeutics and placed directly at the disease site for long-term localized drug delivery. However, it is difficult to directly validate and optimize the diffusion of these doped NPs in in vivo systems. To better study this drug release and diffusion, we developed a custom macroscopic fluorescence imaging system to visualize and quantify fluorescent NP diffusion from spacers in vivo. To validate the platform, we studied the release of free fluorophores, and 30 nm and 200 nm NPs conjugated with the same fluorophores as a model drug, in agar gel phantoms in vitro and in mice in vivo. Our data verified that the diffusion volume was NP size-dependent in all cases. Our near-infrared imaging system provides a method by which NP diffusion from implantable nanoplatform for chemo-radiation therapy spacers can be systematically optimized (eg, particle size or charge) thereby improving treatment efficacy of the platform.

  10. In vitro stability of low-concentration ziconotide alone or in admixtures in intrathecal pumps.

    Science.gov (United States)

    Dupoiron, Denis; Richard, Hélène; Chabert-Desnot, Vincent; Devys, Catherine; Leynia, Pierre; Boisdron-Celle, Michèle

    2014-07-01

    Ziconotide is often administered in combination with other analgesics via an intrathecal pump. Studies have established that ziconotide is stable when delivered alone in high concentrations. No stability data are available, however, for ziconotide given in low concentrations and/or with other analgesics as usually occurs in clinical oncology practice. The objective of this study was to assess the in vitro stability of ziconotide alone and combined with other analgesics in intrathecal pumps at 37 °C, as well as in syringes at 5 °C, to evaluate conditions for storing and transporting preparations. Various ziconotide concentrations (0.1, 0.25, 0.5, and 0.75 μg/mL) were combined with an admixture of ropivacaine (7.5 mg/mL), morphine (7.5 mg/mL), and clonidine (15 μg/mL) in 20-mL intrathecal pumps at 37 °C and in syringes at 5 °C. Solutions of ziconotide alone in concentrations of 0.25, 0.5, 0.75, and 1 μg/mL were introduced into pumps at 37 °C and syringes at 5 °C. Assays were performed using ultra high pressure liquid chromatography. In admixtures, mean ziconotide concentrations decreased linearly to 53.4% (± 3.33%) of baseline after 35 days. When ziconotide was introduced alone in pumps at 37 °C, the residual concentration on day 31 was 35.54% (± 0.04%) with 0.25 μg/mL, 39.37% (± 0.15%) with 0.5 μg/mL, and 44.49% (± 0.18%) with 1 μg/mL. Ziconotide alone or combined with the other analgesics was stable in syringes stored at 5 °C. The preparations complied with the prescriptions, with a mean error of less than 10%, except with the lowest ziconotide concentration (0.1 μg/mL). At the low ziconotide concentrations studied, the degradation of ziconotide admixed with other drugs was linear and only weakly influenced by the baseline concentration. Linear regression with intrapolation to 30 days showed that the degradation of ziconotide admixed with other drugs was consistent with previously published data. © 2014 International Neuromodulation Society.

  11. Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Sridhar, Srinivas; Suh, W. Warren; D'Amico, Anthony V.; Makrigiorgos, G. Mike

    2010-01-01

    Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate 125 I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for ∼4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

  12. 76 FR 3488 - Implantation or Injectable Dosage Form New Animal Drugs; Oxytetracycline and Flunixin

    Science.gov (United States)

    2011-01-20

    .... FDA-2010-N-0002] Implantation or Injectable Dosage Form New Animal Drugs; Oxytetracycline and Flunixin... combination drug injectable solution containing oxytetracycline and flunixin meglumine in cattle. [[Page 3489... veterinary prescription use of HEXASOL (oxytetracycline and flunixin meglumine) Injection for the treatment...

  13. Implants as drug delivery devices for the treatment of eye diseases

    Directory of Open Access Journals (Sweden)

    Gisele Rodrigues da Silva

    2010-09-01

    Full Text Available The treatment of diseases affecting the posterior segment of the eye is limited by the difficulty in transporting effective doses of drugs to the vitreous, retina, and choroid. Topically applied drugs are poorly absorbed due to the low permeability of the external ocular tissues and tearing. The blood-retina barrier limits drug diffusion from the systemic blood to the posterior segment, thus high doses of drug are needed to maintain therapeutic levels. In addition, systemic side effects are common. Intraocular injections could be an alternative, but the fast flowing blood supply in this region, associated with rapid clearance rates, causes drug concentration to quickly fall below therapeutic levels. To obtain therapeutic levels over longer time periods, polymeric sustained-drug release systems implanted within the vitreous are being studied for the treatment of vitreoretinal disorders. These systems are prepared using different kinds of biodegradable or non-biodegradable polymers. This review aims to demonstrate the main characteristics of these drug delivery implants and their potential for clinical application.O tratamento de doenças do segmento posterior do olho é limitado pela dificuldade no transporte de doses efetivas de fármacos para o vítreo, retina e coróide. Os fármacos aplicados topicamente são pouco absorvidos por causa da baixa permeabilidade dos tecidos oculares externos e ao lacrimejamento. Embora a administração sistêmica seja capaz de transportar fármacos para o segmento posterior do olho, as barreiras hemato-aquosa e hematorretiniana dificultam a absorção e, normalmente, são necessárias doses elevadas, as quais estão geralmente associadas a potenciais efeitos adversos. Injeções intravitreais são capazes de transportar fármacos para o segmento posterior do olho, mas é uma técnica invasiva, pouco tolerada pelos pacientes e apresenta riscos de infecções oculares e danos aos tecidos. Visando a obtenção de

  14. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  15. The effect of HPMC and MC as pore formers on the rheology of the implant microenvironment and the drug release in vitro

    DEFF Research Database (Denmark)

    Aho, Johanna; Halme, Amanda; Boetker, Johan

    2017-01-01

    gradually increasing the porosity of the implant and simultaneously release drug from the implant matrix. Different molecular weight grades of methylcellulose (MC) and hydroxypropyl methylcellulose (HPMC) were mixed with polylactide and extruded into model implants containing nitrofurantoin as a model drug...

  16. A COMPARATIVE STUDY OF HEAMOD Y NAMIC PARAMETERS IN LSCS WITH INTRATHECAL FENTANYL - BUPIVACAINE COMBINATION AND BUPIVACAINE ALONE

    Directory of Open Access Journals (Sweden)

    Ramana Prasad

    2015-10-01

    Full Text Available BACKGROUND: Caesarean section is considered as a major abdominal surgery, which requires profound blockade of spinal segments. Spinal anaesthesia is the most elegant approach providing profound anaesthesia and excellent operative conditions. Hypotension, the most clinically significant effect of spinal anaesthesia can occur rapidly and have a significant impact on neonatal outcome. There has been interest in using analgesic additives to local anaesthetics to decrease the dose of local anaesthetics and reduce in incidence of hypotension without compromising intra - operative analgesia, enabling faster motor recovery and providing efficient post - operative analgesia. This study was conducted t o compare the incidence of hypotension between intrathecal fentanyl - bupivacaine combinations with bupivacaine alone in patients undergoing elective LSCS. INTRODUCTION: In Caesarean section, the surgery is major and profound blockade of many spinal segments is required. Strong visceral stimulation is present, sudden cardiovascular changes is compounded by posture and fetal wellbeing may be influenced by several physiologic variables and drugs. Spinal anaesthesia is perhaps the most efficient and elegant appr oach to this challenge. With a small needle and little amount of drug, profound anaesthesia and excellent operating conditions can be readily provided for this major intrabdominal surgery. Spinal hypotension, the most clinically significant aspect of spina l anaesthesia can occur rapidly and may have a significant impact on the neonatal outcome. Recently, there has been an interest in using analgesic additives to subarachnoid local anaesthetic dose so as to reduce the incidence and degree of hypotension but at the same time without compromising intraoperative analgesia and also to enable faster recovery and providing efficient post - operative analgesia. Opioids were the first clinically used selective spinal analgesics after the discovery of opioids

  17. ED50 and ED95 of Intrathecal Bupivacaine Coadministered with Sufentanil for Cesarean Delivery Under Combined Spinal-epidural in Severely Preeclamptic Patients

    Institute of Scientific and Technical Information of China (English)

    Fei Xiao; Wen-Ping Xu; Xiao-Min Zhang; Yin-Fa Zhang; Li-Zhong Wang; Xin-Zhong Chen

    2015-01-01

    Background:Spinal anesthesia was considered as a reasonable anesthetic option in severe preeclampsia when cesarean delivery is indicated,and there is no indwelling epidural catheter or contraindication to spinal anesthesia.However,the ideal dose of intrathecal bupivacaine has not been quantified for cesarean delivery for severe preeclamptic patients.This study aimed to determine the ED50 and ED95 of intrathecal bupivacaine for severely preeclamptic patients undergoing elective cesarean delivery.Methods:Two hundred severely preeclamptic patients are undergoing elective cesarean delivery under combined spinal-epidural anesthesia enrolled in this randomized,double-blinded,dose-ranging study.Patients received 4 mg,6 mg,8 mg,or 10 mg intrathecal hyperbaric bupivacaine with 2.5 μg sufentanil.Successful spinal anesthesia was defined as a T6 sensory level achieved within 10 minutes after intrathecal drug administration and/or no epidural supplement was required during the cesarean section.The ED50 and ED95 were calculated with a logistic regression model.Results:ED50 and ED95 ofintrathecal bupivacaine for successful spinal anesthesia were 5.67 mg (95% confidence interval [CI]:5.20-6.10 mg) and 8.82 mg (95% CI:8.14-9.87 mg) respectively.The incidence of hypotension in Group 8 mg and Group 10 mg was higher than that in Group 4 mg and Group 6 mg (P < 0.05).The sensory block was significantly different among groups 10 minutes after intrathecal injection (P < 0.05).The use of lidocaine in Group 4 mg was higher than that in other groups (P < 0.05).The use of phenylephrine in Group 8 mg and Group 10 mg was higher than that in the other two groups (P < 0.05).The lowest systolic blood pressure before the infant delivery of Group 8 mg and Group 10 mg was lower than the other two groups (P < 0.05).The satisfaction of muscle relaxation in Group 4 mg was lower than other groups (P < 0.05).There was no significant difference in patients' satisfaction and the newborns

  18. Intrathecal ligaments and nerve root tension: possible sources of lumbar pain during spaceflight.

    Science.gov (United States)

    Kershner, David; Binhammer, Robert

    2004-04-01

    Lumbar intrathecal ligaments have recently been demonstrated to randomly bind dorsal nerve roots to the dura within the lumbar vertebral column. Lengthening of the vertebral column and associated lumbar back pain experienced by astronauts is common in microgravity. This study was designed to investigate the relationship of lumbar intrathecal ligaments in spinal lengthening as a possible mechanism for back pain. A two-part study was designed using 36 vertebral columns from embalmed cadavers. There were 12 vertebral columns studied in mid-sagittal section to demonstrate the possible movement of the spinal cord during lengthening of the vertebral column. The remainder were assessed for the amount of tension placed on a dorsal nerve root by the lumbar intrathecal ligament during lengthening of the vertebral column. The spinal cord moves in a cephalic direction approximately 2.8 mm with 4 cm lengthening of the vertebral column. During lengthening, a loss of thoracic and lordotic curvature was noted with an increase in disk height. Tension was significantly increased on the dorsal nerve roots being tethered by the lumbar intrathecal ligaments in comparison to non-tethered nerve roots during lengthening of the vertebral column. A significant amount of tension is placed on dorsal nerve roots tethered by intrathecal ligaments within the lumbar spine during spinal lengthening. These ligaments randomly bind dorsal nerve roots in the lumbar spine and may be involved in the back pain experienced by astronauts in microgravity.

  19. Intrathecal ropivacaine in cesarean delivery | Ateser | Nigerian ...

    African Journals Online (AJOL)

    Objective: The aim of the present study was to evaluate the optimum dose of ropivacaine by comparing three different dosing regimens of isobaric ropivacaine 1% (naropin 10 mg/ml, Astra Zeneca) administered intrathecally and to demonstrate the effects of anesthesia in pregnant women scheduled for cesarean section.

  20. A case of trigeminal hypersensitivity after administration of intrathecal sufentanil and bupivacaine for labor analgesia

    Directory of Open Access Journals (Sweden)

    Adriano Bechara de Souza Hobaika

    2014-01-01

    Full Text Available Rostral spread of intrathecal drugs and sensitization of supraspinal sites may provoke several adverse effects. This case describes a patient with right hemifacial paresthesia, trismus and dysphasia on the trigeminal nerve distribution after intrathecal sufentanil administration. Primigravida, 34 years, 39 weeks of pregnancy, with hypothyroidism and pregnancy induced hypertension. Allergic to latex. In the use of puran T4, 50 μg /day. When the patient presented cervical dilatation of 4 cm, she requested analgesia. She was placed in the sitting position and a spinal puncture was performed with a 27G needle pencil point in L4/L5 (1.5 mg of bupivacaine plus 7.5 μg of sufentanil. Next, was performed an epidural puncture in the same space. It was injected bupivacaine 0.065%, 10 ml, to facilitate the passage of the catheter. After 5 min lying down in the lateral upright position, she complained of perioral and right hemifacial paresthesia, mainly maxillary and periorbital, as well as trismus and difficulty to speak. The symptoms lasted for 30 min and resolved spontaneously. After 1 h, patient requested supplementary analgesia (12 ml of bupivacaine 0.125% and a healthy baby girl was born. Temporary mental alterations have been described with the use of fentanyl and sufentanil in combined epidural-spinal analgesia, such as aphasia, difficulty of swallowing, mental confusion and even unconsciousness. In this patient, facial areas with paresthesia indicated by patient appear in clear association with the ophthalmic and maxillary branches of the trigeminal nerve and the occurrence of trismus and dysphagia are in association with the mandibular motor branch. The exact mechanism of rostral spread is not known, but it is speculated that after spinal drug administration, a subsequent epidural dose may reduce the intratecal space and propel the drug into the supraspinal sites.

  1. Concomitant monitoring of implant formation and drug release of in situ forming poly (lactide-co-glycolide acid) implants in a hydrogel matrix mimicking the subcutis using UV-vis imaging.

    Science.gov (United States)

    Sun, Yu; Jensen, Henrik; Petersen, Nickolaj J; Larsen, Susan W; Østergaard, Jesper

    2018-02-20

    For poly (lactide-co-glycolide acid) (PLGA)-based in situ forming implants, the rate of implant formation plays an important role in determining the overall drug release kinetics. Currently, in vitro techniques capable of characterizing the processes of drug release and implant formation at the same time are not available. A hydrogel-based in vitro experimental setup was recently developed requiring only microliter of formulation and forming a closed system potentially suitable for interfacing with various spectroscopic techniques. The aim of the present proof-of-concept study was to investigate the feasibility of concomitant UV imaging, Vis imaging and light microscopy for detailed characterization of the behavior of in situ forming PLGA implants in the hydrogel matrix mimicking the subcutis. The model compounds, piroxicam and α-lactalbumin were added to PLGA-1-methyl-2-pyrrolidinone and PLGA-triacetin solutions. Upon bringing the PLGA-solvent-compound pre-formulation in contact with the hydrogel, Vis imaging and light microscopy were applied to visualize the depot formation and UV imaging was used to quantify drug transport in the hydrogel. As compared to piroxicam, the α-lactalbumin invoked an acceleration of phase separation and an increase of implant size. α-Lactalbumin was released faster from the PLGA-1-methyl-2-pyrrolidinone system than the PLGA-triacetin system opposite to the piroxicam release pattern. A linear relationship between the rate of implant formation and initial compound release within the first 4h was established for the PLGA-NMP systems. This implies that phase separation may be one of the controlling factors in drug release. The rate of implant formation may be an important parameter for predicting and tailoring drug release. The approach combining UV imaging, Vis imaging and light microscopy may facilitate understanding of release processes and holds potential for becoming a useful tool in formulation development of in situ forming

  2. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    International Nuclear Information System (INIS)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H.; Mauck, William D.; Burke, Michelle M.

    2011-01-01

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  3. Implementation of wireless power transfer and communications for an implantable ocular drug delivery system.

    Science.gov (United States)

    Tang, T B; Smith, S; Flynn, B W; Stevenson, J T M; Gundlach, A M; Reekie, H M; Murray, A F; Renshaw, D; Dhillon, B; Ohtori, A; Inoue, Y; Terry, J G; Walton, A J

    2008-09-01

    A wireless power transfer and communication system based on near-field inductive coupling has been designed and implemented. The feasibility of using such a system to remotely control drug release from an implantable drug delivery system is addressed. The architecture of the wireless system is described and the signal attenuation over distance in both water and phosphate buffered saline is studied. Additionally, the health risk due to exposure to radio frequency (RF) radiation is examined using a biological model. The experimental results demonstrate that the system can trigger the release of drug within 5 s, and that such short exposure to RF radiation does not produce any significant (implantable system, eliminating the risks associated with battery failure and leakage and also allowing more compact designs for applications such as drug delivery.

  4. Experimental study of PLLA/INH slow release implant fabricated by three dimensional printing technique and drug release characteristics in vitro.

    Science.gov (United States)

    Wu, Gui; Wu, Weigang; Zheng, Qixin; Li, Jingfeng; Zhou, Jianbo; Hu, Zhilei

    2014-07-19

    Local slow release implant provided long term and stable drug release in the lesion. The objective of this study was to fabricate biodegradable slow release INH/PLLA tablet via 3 dimensional printing technique (3DP) and to compare the drug release characteristics of three different structured tablets in vitro. Three different drug delivery systems (columnar-shaped tablet (CST), doughnut-shaped tablet (DST) and multilayer doughnut-shaped tablet (MDST)) were manufactured by the three dimensional printing machine and isoniazid was loaded into the implant. Dynamic soaking method was used to study the drug release characteristics of the three implants. MTT cytotoxicity test and direct contact test were utilized to study the biocompatibility of the implant. The microstructures of the implants' surfaces were observed with electron microscope. The PLLA powder in the tablet could be excellently combined through 3DP without disintegration. Electron microscope observations showed that INH distributed evenly on the surface of the tablet in a "nest-shaped" way, while the surface of the barrier layer in the multilayer doughnut shaped tablet was compact and did not contain INH. The concentration of INH in all of the three tablets were still higher than the effective bacteriostasis concentration (Isoniazid: 0.025 ~ 0.05 μg/ml) after 30 day's release in vitro. All of the tablets showed initial burst release of the INH in the early period. Drug concentration of MDST became stable and had little fluctuation starting from the 6th day of the release. Drug concentration of DST and CST decreased gradually and the rate of decrease in concentration was faster in DST than CST. MTT cytotoxicity test and direct contact test indicated that the INH-PLLA tablet had low cytotoxicity and favorable biocompatibility. Three dimensional printing technique was a reliable technique to fabricate complicated implants. Drug release pattern in MDST was the most stable among the three implants. It was

  5. Ceasing intrathecal therapy in chronic non-cancer pain: an invitation to shift from biomedical focus to active management.

    Directory of Open Access Journals (Sweden)

    Chris Hayes

    Full Text Available OBJECTIVE: To report long term experience (1997-2009 of intrathecal (IT therapy for chronic non-cancer pain in the context of our team's increasing emphasis on active management. DESIGN: Descriptive case series. SETTING: Australian tertiary multidisciplinary pain center, Hunter Integrated Pain Service (HIPS. INTERVENTION: This case series reports the changing use of IT implanted drug delivery systems (IDDSs for chronic non-cancer pain over 13 years. Initially IT therapy was used selectively following multidisciplinary assessment and double blind IT trial. Typical therapy combined opioid with clonidine. Multidimensional management was offered. Treatment strategy changed in 2003 due to HIPS experience of limited therapeutic gains and equivocal support for IT therapy in the literature. Subsequently IT therapy was no longer initiated for non-cancer pain and those on established regimes were encouraged to shift to oral/transdermal opioids with greater emphasis on active management. Patient education and consultation were key elements. Where IT cessation was elective gradual dose reduction commenced as an outpatient. In elective and urgent cases ketamine infusion and oral clonidine were used during hospital admissions to cover the switch to oral/transdermal opioids. Over the study period transition occurred to a broader management framework in which IT therapy for chronic non-cancer pain was no longer supported by HIPS. RESULTS: 25 patients were managed using IDDSs; 8 implanted by HIPS and 17 by other teams. Dose escalation and adverse effects were common. 24 of 25 patients ceased IT therapy; 7 (29% with urgent IDDS related complications, 16 (67% electively and 1 due to an unrelated death. The remaining patient returned to her original team to continue IT therapy. One post-explantation patient transferred to another team to recommence IT therapy. The remainder were successfully maintained on oral/transdermal opioids combined with active management.

  6. Intrathecal Versus Oral Baclofen: A Matched Cohort Study of Spasticity, Pain, Sleep, Fatigue, and Quality of Life.

    Science.gov (United States)

    McCormick, Zachary L; Chu, Samuel K; Binler, Danielle; Neudorf, Daniel; Mathur, Sunjay N; Lee, Jungwha; Marciniak, Christina

    2016-06-01

    Baclofen commonly is used to manage spasticity caused by central nervous system lesions or dysfunction. Although both intrathecal and oral delivery routes are possible, no study has directly compared clinical outcomes associated with these 2 routes of treatment. To compare spasticity levels, pain, sleep, fatigue, and quality of life between individuals receiving treatment with intrathecal versus oral baclofen. Cross-sectional matched cohort survey study. Urban academic rehabilitation outpatient clinics. Adult patients with spasticity, treated with intrathecal or oral baclofen for at least 1 year, matched 1:1 for age, gender, and diagnosis. Standardized surveys were administered during clinic appointments or by telephone. Surveys included the Penn Spasm Frequency Scale, Brief Pain Inventory, Epworth Sleepiness Scale, Fatigue Severity Scale, Life Satisfaction Questionnaire, and Diener Satisfaction with Life Scale. A total of 62 matched subjects were enrolled. The mean (standard deviation [SD]) age was 46 (11) years with a mean duration of intrathecal baclofen or oral baclofen treatment of 11 (6) and 13 (11) years, respectively. There were 40 (64%) male and 22 (36%) female subjects. Primary diagnoses included spinal cord injury (n = 38), cerebral palsy (n = 10), stroke (n = 10), and multiple sclerosis (n = 4). The mean (SD) dose of intrathecal and oral baclofen at the time of survey were 577 (1429) μg/day and 86 (50) mg/day, respectively. Patients receiving intrathecal compared with oral baclofen experienced significantly fewer (1.44 [0.92] versus 2.37 [1.12]) and less severe (1.44 [0.92] versus 2.16 [0.83]) spasms, respectively as measured by the Penn Spasm Frequency Scale (P life between groups. Subanalysis of patients with SCI mirrored results of the entire study sample, with significant decreases in spasm frequency and severity associated with intrathecal compared to oral baclofen (P < .01; P < .01), but no other between group differences. The mean (SD) percent

  7. Comparison of Major Immunoglobulins Intrathecal Synthesis Patterns in Ecuadorian and Cuban Patients with Angiostrongyliasis

    Science.gov (United States)

    Padilla-Docal, Bárbara; Dorta-Contreras, Alberto J.; Moreira, Juan M.; Martini-Robles, Luiggi; Muzzio-Aroca, Jenny; Alarcón, Fernando; Magraner-Tarrau, María Esther; Bu-Coifiu-Fanego, Raisa

    2011-01-01

    Angiostrongylus cantonensis meningitis was first reported in Cuba in 1981, and it was recently reported in South America. The aim of this paper is to evaluate the intrathecal immunoglobulin synthesis patterns from Cuba's and Ecuador's patients with angiostrongyliasis; 8 Ecuadorian patients from two different outbreaks and 28 Cuban patients were studied. Simultaneous blood and cerebrospinal fluid simples were taken. Immunoglobulin (Ig) A, IgM, IgG, and albumin were quantified by radial immunodiffusion. Corresponding Reibergrams were applied. A three-Ig pattern was the most frequent in the two groups, but IgM was presented in all Ecuadorian young mature patients; however, in the Cuban children, only 12 of 28 patients had intrathecal IgM, but about 90% had an IgA and IgG synthesis at time of later puncture. This indicates that, with a larger amount of parasites ingested, clinical symptoms are more severe, and a higher frequency of intrathecal IgM synthesis could be observed. This is discussed as a similarity with the intrathecal IgM synthesis in African trypanosomiasis. PMID:21363978

  8. Evaluating glymphatic pathway function utilizing clinically relevant intrathecal infusion of CSF tracer.

    Science.gov (United States)

    Yang, Lijun; Kress, Benjamin T; Weber, Harris J; Thiyagarajan, Meenakshisundaram; Wang, Baozhi; Deane, Rashid; Benveniste, Helene; Iliff, Jeffrey J; Nedergaard, Maiken

    2013-05-01

    Neurodegenerative diseases such as Alzheimer's are associated with the aggregation of endogenous peptides and proteins that contribute to neuronal dysfunction and loss. The glymphatic system, a brain-wide perivascular pathway along which cerebrospinal fluid (CSF) and interstitial fluid (ISF) rapidly exchange, has recently been identified as a key contributor to the clearance of interstitial solutes from the brain, including amyloid β. These findings suggest that measuring changes in glymphatic pathway function may be an important prognostic for evaluating neurodegenerative disease susceptibility or progression. However, no clinically acceptable approach to evaluate glymphatic pathway function in humans has yet been developed. Time-sequenced ex vivo fluorescence imaging of coronal rat and mouse brain slices was performed at 30-180 min following intrathecal infusion of CSF tracer (Texas Red- dextran-3, MW 3 kD; FITC- dextran-500, MW 500 kD) into the cisterna magna or lumbar spine. Tracer influx into different brain regions (cortex, white matter, subcortical structures, and hippocampus) in rat was quantified to map the movement of CSF tracer following infusion along both routes, and to determine whether glymphatic pathway function could be evaluated after lumbar intrathecal infusion. Following lumbar intrathecal infusions, small molecular weight TR-d3 entered the brain along perivascular pathways and exchanged broadly with the brain ISF, consistent with the initial characterization of the glymphatic pathway in mice. Large molecular weight FITC-d500 remained confined to the perivascular spaces. Lumbar intrathecal infusions exhibited a reduced and delayed peak parenchymal fluorescence intensity compared to intracisternal infusions. Lumbar intrathecal contrast delivery is a clinically useful approach that could be used in conjunction with dynamic contrast enhanced MRI nuclear imaging to assess glymphatic pathway function in humans.

  9. A COMPARATIVE STUDY OF INTRATHECAL DEXMEDETOMIDINE AND FENTANYL AS ADJUVANTS TO BUPIVACAINE FOR LOWER ABDOMINAL SURGERIES

    Directory of Open Access Journals (Sweden)

    Hari Kishore

    2015-01-01

    Full Text Available INTRODUCTION: Various adjuvants have been used with local anesthetics in spinal anesthesia to improve the quality of block and to provide prolonged postoperative analgesia. Dexmedetomidine, the new highly selective α2 - agonist drug, is now being used as a neuraxial adju vant. AIM: The aim of this study was to evaluate the onset and duration of sensory and motor block, hemodynamic effect, postoperative analgesia, and adverse effects of dexmedetomidine or fentanyl given intrathecally with hyperbaric 0.5% bupivacaine. METHOD OLOGY: Fifty patients classified in American Society of Anesthesiologists classes I and II scheduled for lower abdominal surgeries were included in this prospective cohort study at Amala Institute of Medical Sciences. Patients received either 15 mg hyperba ric bupivacaine plus 25 μg fentanyl (group 1, n = 25 or 15 mg hyperbaric bupivacaine plus 5 μg dexmedetomidine (group 2, n = 25 intrathecally . RESULTS : Patients in dexmedetomidine group (2 had a significantly longer duration of motor and sensory block t han patients in fentanyl group . (1 The mean time regression of motor block to reach Bromage 0 was 17 6 . 2± 5.71 min in d exmeditomid ine group and 16 6 . 36 ± 5.97 min in fentanyl group (P<0.05. Duration of analgesia was 2 39.52 ± 9.05 min in D exmed i tomidine gro up and 189.96 ± 5.35 min in fentanyl group ( p< 0.05. A significant decrease in heart rate was noted in dexmedetomidine group. CONCLUSION : Intrathecal dexmedetomidine is associated with prolonged duration of analgesia and motor block along with significant dec rease in heart rate.

  10. Ultrasound Pulsed-Wave Doppler Detects an Intrathecal Location of an Epidural Catheter Tip: A Case Report.

    Science.gov (United States)

    Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat

    2018-04-01

    Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.

  11. Approaches and Challenges of Engineering Implantable Microelectromechanical Systems (MEMS Drug Delivery Systems for in Vitro and in Vivo Applications

    Directory of Open Access Journals (Sweden)

    Ken-Tye Yong

    2012-11-01

    Full Text Available Despite the advancements made in drug delivery systems over the years, many challenges remain in drug delivery systems for treating chronic diseases at the personalized medicine level. The current urgent need is to develop novel strategies for targeted therapy of chronic diseases. Due to their unique properties, microelectromechanical systems (MEMS technology has been recently engineered as implantable drug delivery systems for disease therapy. This review examines the challenges faced in implementing implantable MEMS drug delivery systems in vivo and the solutions available to overcome these challenges.

  12. Combined spinal epidural analgesia for labor using sufentanil epidurally versus intrathecally: a retrospective study on the influence on fetal heart trace

    NARCIS (Netherlands)

    Everaert, Nele; Coppens, Marc; Vlerick, Peter; Braems, Geert; Wouters, Patrick; de Hert, Stefan

    2015-01-01

    Objective: We retrospectively compared a protocol using sufentanil and ropivacaine intrathecally with a protocol in which only ropivacaine was administered intrathecally and sufentanil was used epidurally to evaluate whether banning sufentanil from the intrathecal space results in a decreased

  13. [Intrathecal baclofen therapy for spastic paraparesis due to aortic dissecting aneurysm; recent progress in treatment strategy].

    Science.gov (United States)

    Nakajima, T; Akagawa, H; Ochiai, T; Hayashi, M; Goto, S; Taira, T; Okada, Y

    2009-11-01

    A 48-year-old man suffered from acute dissection of thoracic aortic aneurysm which eventually led to replacement of the ascending aorta with a tube graft. During this clinical course, circulatory failure in intercostal artery resulted in spinal cord infarction followed by moto-sensory disturbance below Th7 dermatomic area. Seven months later, spasticity with pain in both lower extremities became conspicuous that was uncontrollable by any oral medication. Eventually the patient underwent the implantation of continuous infusion pump for intrathecal baclofen therapy (ITB). The clinical condition was remarkably improved and now has been well controlled. ITB, authorized by Japanese Ministry of Health Labour and Welfare in 2006, has notable therapeutic effects on spasticity derived from any sort of central nervous disorder. More promotive enlightenment if ITB is indispensable for enhancement of its medical benefit in Japan.

  14. Efficacy of intrathecal midazolam versus fentanyl for endoscopic

    African Journals Online (AJOL)

    intrathecal midazolam versus fentanyl as an adjunct to bupivacaine for endoscopic urology surgery. Methods: Sixty adult ASA grade I–II patients undergoing transurethral resection of prostate or bladder tumor under spinal block. Postoperative analgesia was provided with intravenous diclofenac. The onset and duration of ...

  15. Dosimetry in intrathecal radiogold therapy. 2

    International Nuclear Information System (INIS)

    Doege, H.; Hennig, K.

    1978-01-01

    Measurements of 198 Au colloid adsorbed at the surface of the subarachnoid cavities are described. 24 hours after intrathecal administration less than 1% of radiogold is freely moving in the liquor, i.e., more than 99% are adsorbed on the walls of the cavities. Therefore, in calculating the absorbed dose the surface of all anatomic structures forming the boundary of the subarachnoid cavities has to be taken into account. (author)

  16. Intrathecal sufentanil versus fentanyl for lower limb surgeries - A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Poonam Motiani

    2011-01-01

    Full Text Available Background:To compare the efficacy and safety of intrathecal sufentanil or fentanyl as adjuvants to hyperbaric bupivacaine in patients undergoing major orthopaedic lower limb surgeries in terms of onset and duration of sensory block, motor block and post-operative pain relief. Patients & Methods: Ninety patients were recruited in this Prospective, randomized double blind study to receive either intrathecal sufentanil 5 μg (Group S, fentanyl 25 μg (Group F or normal saline 0.5 ml (Group C as adjuvants to 15 mg of 0.5% hyperbaric bupivacaine. The onset and duration of sensory and motor block were assessed intraoperatively. The pain scores were assessed postoperatively. Duration of complete and effective analgesia was recorded. The incidence of side effects such as nausea, vomiting, pruritus, shivering and PDPH was recorded. Results: The Demographic data, hemodynamic and respiratory parameters were comparable in the three groups. There was a significantly earlier onset and prolonged duration of sensory block in the sufentanil and fentanyl groups. The duration of complete and effective analgesia were also significantly prolonged in the fentanyl and sufentanil groups. Pruritus was noticed in the study groups (Groups S&F. Conclusions: Intrathecal sufentanil (5 μg and fentanyl (25 μg, as adjuvants lead to an earlier onset and prolonged duration of sensory block. The duration of effective analgesia with intrathecal sufentanil and fentanyl as adjuvants to hyperbaric bupivacaine is longer than that of bupivacaine alone.

  17. A comparison of intrathecal dexmedetomidine verses intrathecal fentanyl with epidural bupivacaine for combined spinal epidural labor analgesia

    OpenAIRE

    P K Dilesh; S Eapen; S Kiran; Vivek Chopra

    2014-01-01

    Context: Combined spinal epidural (CSE) analgesia technique is effective for labor analgesia and various concentrations of bupivacaine and lipophilic opioids like fentanyl have been studied. Dexmedetomidine is a highly selective alpha 2 adrenoreceptor agonist with analgesic properties and has been used intrathecally with bupivacaine for prolonged postoperative analgesia. Recent reviews have shown that it is highly lipophilic and does not cross placenta significantly. Aim: The aim of this s...

  18. 76 FR 22610 - Implantation or Injectable Dosage Form New Animal Drugs; Enrofloxacin

    Science.gov (United States)

    2011-04-22

    .... FDA-2011-N-0003] Implantation or Injectable Dosage Form New Animal Drugs; Enrofloxacin AGENCY: Food... the indications for use of enrofloxacin solution in cattle, as a single injection, for the treatment... supplement to NADA 141-068 for BAYTRIL 100 (enrofloxacin), an injectable solution. The supplemental NADA...

  19. 78 FR 38994 - Implanted Blood Access Devices for Hemodialysis; Draft Guidance for Industry and Food and Drug...

    Science.gov (United States)

    2013-06-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0749] Implanted Blood Access Devices for Hemodialysis; Draft Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...

  20. Transdermal power transfer for recharging implanted drug delivery devices via the refill port.

    Science.gov (United States)

    Evans, Allan T; Chiravuri, Srinivas; Gianchandani, Yogesh B

    2010-04-01

    This paper describes a system for transferring power across a transdermal needle into a smart refill port for recharging implantable drug delivery systems. The device uses a modified 26 gauge (0.46 mm outer diameter) Huber needle with multiple conductive elements designed to couple with mechanical springs in the septum of the refill port of a drug delivery device to form an electrical connection that can sustain the current required to recharge a battery during a reservoir refill session. The needle is fabricated from stainless steel coated with Parylene, and the refill port septum is made from micromachined stainless steel contact springs and polydimethylsiloxane. The device properties were characterized with dry and wet ambient conditions. The needle and port pair had an average contact resistance of less than 2 Omega when mated in either environment. Electrical isolation between the system, the liquid in the needle lumen, and surrounding material has been demonstrated. The device was used to recharge a NiMH battery with currents up to 500 mA with less than 15 degrees C of resistive heating. The system was punctured 100 times to provide preliminary information with regard to device longevity, and exhibited about 1 Omega variation in contact resistance. The results suggest that this needle and refill port system can be used in an implant to enable battery recharging. This allows for smaller batteries to be used and ultimately increases the volume efficiency of an implantable drug delivery device.

  1. Comparative study of clindamycin concentration in the cerebrospinal fluid after intravenous and intrathecal administration in patients with toxoplasmic meningoencephalitis

    Directory of Open Access Journals (Sweden)

    Сергій Петрович Борщов

    2015-07-01

    Full Text Available Aim of the work: to study the difference of clindamycin concentration in CSF at the intravenous and combined (intrathecal + intravenous ways of administration of preparation.Materials and methods: study was carried out at the treatment of 11 HIV-positive patients 27-63 years old (men and women with toxoplasmic meningoencephalitises.There was measured the clindamycin concentration in CSF of every patient after intravenous and combined (intrathecal + intravenous ways of administration of preparation. The determinations of concentration were done by the way of the reverse-phase high-performance liquid chromatography (HPLC with ultraviolet (UV detection. Statistic processing of the received data was carried out using the Wilcoxon criterion.Results of research. There was received the statistically significant increase of clindamycin concentration in CSF of patients in a day after combined (intrathecal + intravenous administration of preparation comparing with an intravenous administration.Conclusions. 1. Intrathecal administration of 150 mg. of clindamycin with 8 mg. of dexamethasone is safe.2. Intrathecal administration of 150 mg. of clindamycin with 8 mg. of dexamethasone in combination with an intravenous administration of preparation leads to statistically significant increase of clindamycin concentration in CSF at least during a day after injection.3. Intrathecal administration of clindamycin with dexamethasone in offered doses can be recommended for treatment of meningoencephalitises that caused by microorganisms susceptible to clindamycin.4. If the therapy of toxoplasmic meningoencephalitis was started with an intravenous prescription of clindamycin it is recommended an additional treatment with an intrathecal administration of clindamycin with dexamethasone in offered doses to increase efficiency by creating an effective concentration of preparation in the nidus of infection.5. Intrathecal methods of therapy must be used by the specialists of

  2. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    Energy Technology Data Exchange (ETDEWEB)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mauck, William D. [Mayo Clinic, Department of Anesthesiology, Rochester, MN (United States); Burke, Michelle M. [Mayo Clinic, Department of Psychiatry and Psychology, Rochester, MN (United States)

    2011-02-15

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  3. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    Science.gov (United States)

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  4. Comparative Study of Intrathecal Dexamethasone with Epinephrine as Adjuvants to Lidocaine in Cesarean Section

    Directory of Open Access Journals (Sweden)

    Fereshteh Naziri

    2013-09-01

    Full Text Available Background: Different additives have been used with local anesthetics to provide prolonged duration of sensory block in spinal anesthesia. The aim of present study was to evaluate the onset and duration of sensory block of intrathecal dexamethasone and epinephrine as adjuvants to lidocaine in patients who were candidate for cesarean section. Materials and Methods: This double-blind clinical trial research was conducted on 90 pregnant women candidate for cesarean section under spinal anesthesia. Patients were randomly allocated to receive intrathecally either 75 mg hyperbaric lidocaine plus 100 μg epinephrine or 75 mg hyperbaric lidocaine plus 4 mg dexamethasone or 75 mg hyperbaric lidocaine. The onset and duration of sensory block as well as postoperative analgesia were assessed. Results: The time to reach the peak sensory block in lidocaine group was shorter than that of other two groups (p<0.001. Duration of sensory block in the control group, dexamethasone group, and epinephrine group were 64.16±7.99 min, 74.79±12.78 min, and 99.30±10.93 min, respectively (p<0.001. Conclusion: The present research shows that intrathecal dexamethasone and intrathecal epinephrine as adjuvant to lidocaine increases sensory block duration in the women candidate for cesarean section.

  5. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne Kjer

    2013-01-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.......This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention....

  6. Severe neurotoxicity associated to the intrathecal of metotreaxate and cytanobina in patients with tenkenic or lymphoma

    International Nuclear Information System (INIS)

    Garcia Tena, J.; Lopez Andreu, J.A.; Verdeguer, A.; Menor, F.; Mulas, F.; Ferris, J.

    1995-01-01

    The prophylaxis and treatment of central nervous system leukemia and lymphoma with intrathecal chemotherapy have been related to severe neurotoxicity. At least 35 cases of subacute myeloencepthalopathy with transient a permanent paraplegia/quadriplegia have been reported. A comprehensive view of the literature and a description of a new case of intrathecal chemotherapy-related neurotoxicity is made. Among the cases reported in the literature, complete recovery was observed in 9 patients, partial recovery with variable sequelae in 6, no recovery in 8 and 13 patients died. Early cerebrospinal fluid exchange seems to be the only potentially effective approach although not universally accepted. The rarity of this toxicity and the proved efficacy of the intrathecal chemotherapy justify its use

  7. An implantable thermoresponsive drug delivery system based on Peltier device.

    Science.gov (United States)

    Yang, Rongbing; Gorelov, Alexander V; Aldabbagh, Fawaz; Carroll, William M; Rochev, Yury

    2013-04-15

    Locally dropping the temperature in vivo is the main obstacle to the clinical use of a thermoresponsive drug delivery system. In this paper, a Peltier electronic element is incorporated with a thermoresponsive thin film based drug delivery system to form a new drug delivery device which can regulate the release of rhodamine B in a water environment at 37 °C. Various current signals are used to control the temperature of the cold side of the Peltier device and the volume of water on top of the Peltier device affects the change in temperature. The pulsatile on-demand release profile of the model drug is obtained by turning the current signal on and off. The work has shown that the 2600 mAh power source is enough to power this device for 1.3 h. Furthermore, the excessive heat will not cause thermal damage in the body as it will be dissipated by the thermoregulation of the human body. Therefore, this simple novel device can be implanted and should work well in vivo. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Chiron Vision files FDA application to market intraocular implant for CMV retinitis. Food and Drug Administration.

    Science.gov (United States)

    1995-07-01

    Chiron Corporation and Hoffman-LaRoche announced a filing of a New Drug Application with the Food and Drug Administration (FDA) to market Vitrasert, its intraocular implant which delivers ganciclovir directly to the eye for treatment of CMV retinitis. Clinical trials show that Vitrasert offers a clinical improvement versus intravenous ganciclovir in further delaying progression of CMV retinitis in the treated eye. One study reported that the median time to progression of CMV retinitis was 186 days for eyes receiving Vitrasert compared to 72 days for eyes receiving intravenous ganciclovir therapy. Chiron's intraocular implant contains ganciclovir embedded in a polymer-based system that slowly releases the drug into the eye for up to eight months. Two additional trials are underway. For further information contact the Professional Services Group at Chiron Corporation at (800) 244-7668, select 2.

  9. An Implantable MEMS Drug Delivery Device for Rapid Delivery in Ambulatory Emergency Care

    Science.gov (United States)

    2009-06-01

    controlled devices provide advantages over passive release devices, as the drug delivery process can be controlled actively after implantation and...mm, 5 μm, 100 Å, Alltech Associates, USA), with methanol and 0.1% trifluoroacetic acid (TFA) in water. The gradient used was 2 % TFA/min, starting

  10. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  11. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2015-11-01

    Recently, the "glymphatic system" of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain.

  12. The effect of intrathecal midazolam on the characteristics of ...

    African Journals Online (AJOL)

    Objectives: The present study was undertaken to determine the onset of sensory block, the time to achieve the maximum level of sensory block and the analgesic efficacy of intrathecal midazolam when given in combination with bupivacaine, and also to observe any undesirable side-effects produced by the ...

  13. Feasibility of subcutaneously implanted magnetic microarrays for site specific drug and gene targeting

    Directory of Open Access Journals (Sweden)

    M. Babincová

    2010-01-01

    Full Text Available The magnetic nanoparticles play a crucial role as a drug carriers in the human body. The wedge like magnetic arrays creatinga strongly non-homogeneous magnetic field are considered as a useful way to focus magnetic nanoparticles functionalizedwith various drugs or genes to desired sites. The goal of this study is to develop a numerical model of drug targetingusing subcutaneously implanted magnetic microarrays. The Finite Element Method is applied to solve partial differentialequations describing electromagnetic field (Maxwell equations and motion of these particles in a given magnetic field isobtained solving set of ordinary differential equations expressed by Newton law of motion. The results are encouragingshowing the potential to target drug to the tumour cell locally, without unwanted side effects.

  14. Benefits of using intrathecal buprenorphine.

    Science.gov (United States)

    Rabiee, Seyed Mozaffar; Alijanpour, Ebrahim; Jabbari, Ali; Rostami, Sara

    2014-01-01

    General anesthesia draws attention to the most commonly used modalities for post cesarean delivery pain relief in systemic administration of opioids, while the administration of small dose of intrathecal opioid during spinal anesthesia can be a possible alternative. The aim of this study was to evaluate the effects of buprenorphine on cesarean section prescribed intrathecally. This double blind randomized clinical trial study was conducted in patients for cesarean section under spinal anesthesia. The patients were randomly divided into case and control groups. Case group (208 patients) received 65-70 mg of 5% lidocaine plus 0.2 ml of buprenorphine while the same amount of 5% lidocaine diluted with 0.2 ml of normal saline was given to 234 cases in the control group. Hemodynamic changes and neonatal APGAR scores (Appearance, Pulse, Grimace, Activity, Respiration) were recorded. Pain score was recorded according to the visual analog scale. This study was registered in the Iranian Registry of clinical Trials; IRCT2013022112552N1. The mean age of case and control groups was 24.4±5.38 and 26.84±5.42 years, respectively. Systolic blood pressure was not significantly different until the 45th minute but diastolic blood pressure showed a significant difference at the 15th and the 60th minutes (P<0.001). Heart rate changes were significantly different between cases and controls at the initial 5th, 15th and after 60th minutes (P<0.001). Pain-free period was significantly different between two groups (1.25 h versus 18.73 h) (P<0.001). The results show that prescription of intratechal buprenorphine prolongs the duration of analgesia without any significant considerable side effects.

  15. Magnetic nanoparticles for local drug delivery using magnetic implants

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Pacheco, Rodrigo [Instituto Universitario de Investigacion en Nanociencia de Aragon (INA), Universidad de Zaragoza, Edif. Inter. II, 50009 Zaragoza (Spain); Marquina, Clara [Instituto de Ciencia de Materiales de Aragon (ICMA), CSIC-Universidad de Zaragoza, Facultad de Ciencias, 50009 Zaragoza (Spain); Gabriel Valdivia, J. [Instituto Universitario de Investigacion en Nanociencia de Aragon (INA), Universidad de Zaragoza, Edif. Inter. II, 50009 Zaragoza (Spain); Hospital Clinico Universitario ' Lozano Blesa' , Avda Gomez Laguna, 50009 Zaragoza (Spain)] (and others)

    2007-04-15

    Magnetic nanoparticles are good candidates used for the targeted delivery of anti-tumor agents. They can be concentrated on a desired region, reducing collateral effects and improving the efficiency of the chemotherapy. We propose a method in which permanent magnets are implanted by laparoscopic technique directly in the affected organ. This method proposes the use of FeC nanoparticles, which are loaded with doxorubicin and injected intravenously. The particles, once attracted to the magnet, release the drug at the tumor region. This method seems to be more promising and effective than that based on the application of external magnetic fields.

  16. Magnetic nanoparticles for local drug delivery using magnetic implants

    International Nuclear Information System (INIS)

    Fernandez-Pacheco, Rodrigo; Marquina, Clara; Gabriel Valdivia, J.

    2007-01-01

    Magnetic nanoparticles are good candidates used for the targeted delivery of anti-tumor agents. They can be concentrated on a desired region, reducing collateral effects and improving the efficiency of the chemotherapy. We propose a method in which permanent magnets are implanted by laparoscopic technique directly in the affected organ. This method proposes the use of FeC nanoparticles, which are loaded with doxorubicin and injected intravenously. The particles, once attracted to the magnet, release the drug at the tumor region. This method seems to be more promising and effective than that based on the application of external magnetic fields

  17. Efficacy of intravenous plus intrathecal/intracerebral ventricle injection of polymyxin B for post-neurosurgical intracranial infections due to MDR/XDR Acinectobacter baumannii: a retrospective cohort study

    OpenAIRE

    Pan, Sijun; Huang, Xiaofang; Wang, Yesong; Li, Li; Zhao, Changyun; Yao, Zhongxiang; Cui, Wei; Zhang, Gensheng

    2018-01-01

    Background Post-neurosurgical intracranial infections caused by multidrug-resistant or extensively drug-resistant Acinetobacter baumannii are difficult to treat and associated with high mortality. In this study, we analyzed the therapeutic efficacy of intravenous combined with intrathecal/intracerebral ventricle injection of polymyxin B for this type of intracranial infection. Methods This retrospective study was conducted from January 2013 to September 2017 at the Second Affiliated Hospital,...

  18. Efficacy of intravenous plus intrathecal/intracerebral ventricle injection of polymyxin B for post-neurosurgical intracranial infections due to MDR/XDR Acinectobacter baumannii: a retrospective cohort study

    OpenAIRE

    Sijun Pan; Xiaofang Huang; Yesong Wang; Li Li; Changyun Zhao; Zhongxiang Yao; Wei Cui; Gensheng Zhang

    2018-01-01

    Abstract Background Post-neurosurgical intracranial infections caused by multidrug-resistant or extensively drug-resistant Acinetobacter baumannii are difficult to treat and associated with high mortality. In this study, we analyzed the therapeutic efficacy of intravenous combined with intrathecal/intracerebral ventricle injection of polymyxin B for this type of intracranial infection. Methods This retrospective study was conducted from January 2013 to September 2017 at the Second Affiliated ...

  19. First-in-Man Intrathecal Application of Neurite Growth-Promoting Anti-Nogo-A Antibodies in Acute Spinal Cord Injury.

    Science.gov (United States)

    Kucher, Klaus; Johns, Donald; Maier, Doris; Abel, Rainer; Badke, Andreas; Baron, Hagen; Thietje, Roland; Casha, Steven; Meindl, Renate; Gomez-Mancilla, Baltazar; Pfister, Christian; Rupp, Rüdiger; Weidner, Norbert; Mir, Anis; Schwab, Martin E; Curt, Armin

    2018-05-01

    Neutralization of central nervous system neurite growth inhibitory factors, for example, Nogo-A, is a promising approach to improving recovery following spinal cord injury (SCI). In animal SCI models, intrathecal delivery of anti-Nogo-A antibodies promoted regenerative neurite growth and functional recovery. This first-in-man study assessed the feasibility, safety, tolerability, pharmacokinetics, and preliminary efficacy of the human anti-Nogo-A antibody ATI355 following intrathecal administration in patients with acute, complete traumatic paraplegia and tetraplegia. Patients (N = 52) started treatment 4 to 60 days postinjury. Four consecutive dose-escalation cohorts received 5 to 30 mg/2.5 mL/day continuous intrathecal ATI355 infusion over 24 hours to 28 days. Following pharmacokinetic evaluation, 2 further cohorts received a bolus regimen (6 intrathecal injections of 22.5 and 45 mg/3 mL, respectively, over 4 weeks). ATI355 was well tolerated up to 1-year follow-up. All patients experienced ≥1 adverse events (AEs). The 581 reported AEs were mostly mild and to be expected following acute SCI. Fifteen patients reported 16 serious AEs, none related to ATI355; one bacterial meningitis case was considered related to intrathecal administration. ATI355 serum levels showed dose-dependency, and intersubject cerebrospinal fluid levels were highly variable after infusion and bolus injection. In 1 paraplegic patient, motor scores improved by 8 points. In tetraplegic patients, mean total motor scores increased, with 3/19 gaining >10 points, and 1/19 27 points at Week 48. Conversion from complete to incomplete SCI occurred in 7/19 patients with tetraplegia. ATI335 was well tolerated in humans; efficacy trials using intrathecal antibody administration may be considered in acute SCI.

  20. A comparative study of the effect of clonidine, fentanyl, and the combination of both as adjuvant to intrathecal bupivacaine for postoperative analgesia in total abdominal hysterectomy

    Science.gov (United States)

    Ahmed, Fareed; Khandelwal, Mamta; Sharma, Anil

    2017-01-01

    Background and Aims: The aim of this study was to evaluate the level of sensory block, onset and duration of motor block, postoperative analgesia, and adverse effects of combination of clonidine and fentanyl given intrathecally with hyperbaric bupivacaine (HB). Material and Methods: Three hundred and twenty eight patients were randomized into four groups. Group bupivacaine (group B) received 15 mg of HB; group bupivacaine clonidine (group BC) received 15 mg of HB plus 25 μg clonidine; group bupivacaine fentanyl (group BF) received 15 mg of HB plus 25 μg fentanyl and group bupivacaine clonidine fentanyl (group BCF) received 15 mg of HB plus 25 μg clonidine and 25 μg fentanyl intrathecally. All groups were evaluated for level of sensory block, onset and duration of motor block, postoperative analgesia, VAS score, sedation score and adverse effects of study drugs. All the data were analyzed using unpaired t-test. P < 0.05 was considered significant. Results: The level of sensory block, onset, and duration of motor block were comparable in all groups. Total duration of analgesia was 407.3 ± 20 min in group BCF compared to 242.1 ± 2 min and 209.2 ± 16 in groups BC and BF, respectively. Lesser doses of rescue analgesic were required in group BCF. The time interval from intrathecal injection to two-segment regression was statistically significant in study groups. Only 2.4% patients showed mild sedation in BCF group. Conclusion: We found that combination of intrathecal clonidine and fentanyl along with bupivacaine increases the total duration of analgesia without significant side effects. PMID:28413281

  1. Recent advances in the design of drug-loaded polymeric implants for the treatment of solid tumors.

    Science.gov (United States)

    Wadee, Ameena; Pillay, Viness; Choonara, Yahya E; du Toit, Lisa C; Penny, Clement; Ndesendo, Valence M K; Kumar, Pradeep; Murphy, Caragh S

    2011-10-01

    The effective treatment of solid tumors continues to be a great challenge to clinicians, despite the development of novel drugs. In order to improve the clinical efficacy of existing chemotherapeutic agents, researchers have considered the possibility of site-specific solid tumor treatment. The greatest advantage of localized delivery is the significantly fewer side effects experienced by patients. Recently, in situ forming implants have attracted considerable interest. These polymeric systems are injected as solutions into tumor sites and the injected solution forms an implant as a result of local environmental stimuli and hence removes the need for surgical implantation. This review summarizes the attempts that have been made to date in the development of polymeric implants for the treatment of solid tumors. Both in situ forming implants and preformed implants, fabricated using natural and synthetic polymers, are described. In addition, the peri- or intra-tumoral delivery of chemotherapeutic agents based on implants inserted surgically into the affected region is also discussed along with a short coverage of implants having an undesirable initial burst release effect. Although these implants have been shown to improve the treatment of various solid tumors, the ideal implant that is able to deliver high doses of chemotherapeutics to the tumor site, over prolonged periods with relatively few side effects on normal tissue, is yet to be formulated.

  2. Intrathecal morphine for postoperative analgesia in patients with idiopathic scoliosis undergoing posterior spinal fusion.

    Science.gov (United States)

    Tripi, Paul A; Poe-Kochert, Connie; Potzman, Jennifer; Son-Hing, Jochen P; Thompson, George H

    2008-09-15

    A retrospective study of postoperative pain management with intrathecal morphine. Identify the dosing regimen of intrathecal morphine that safely and effectively provides postoperative analgesia with minimal complications in patients with idiopathic scoliosis undergoing posterior spinal fusion (PSF) and segmental spinal instrumentation (SSI). Postoperative pain after surgery for idiopathic scoliosis is a concern. Intrathecal morphine has been used to decrease pain. However, the most appropriate dose has not been determined. We retrospectively analyzed 407 consecutive patients with idiopathic scoliosis who underwent PSF and SSI at our institution from 1992 through 2006. Patients were divided into 3 groups based on the intrathecal morphine dose: no dose (n = 68); moderate dose of 9 to 19 microg/kg, mean 14 microg/kg (n = 293); and high dose of 20 microg/kg or greater, mean 24 microg/kg (n = 46). Data included demographics, Wong-Baker visual analog scale postoperative pain scores, postoperative intravenous morphine requirements, time to first rescue dose of intravenous morphine, and postoperative complications of pruritus, nausea/vomiting, respiratory depression, and pediatric intensive care unit (PICU) admission. The demographics of the 3 study groups showed no statistical differences. The mean Wong-Baker visual analog scale pain score in the post anesthesia care unit was 5.2, 0.5, and 0.2, and the mean time to first morphine rescue was 6.6, 16.7, and 22.9 hours, respectively. In the first 48 postoperative hours, respiratory depression occurred in 1 (1.5%), 8 (2.7%), and 7 (15.2%) patients, whereas PICU admission occurred in 0 (0%), 6 (2%), and 8 (17.4%) patients, respectively. The majority of PICU admissions were the result of respiratory depression. Frequency of pruritus and nausea/vomiting was similar in all 3 groups. Intrathecal morphine in the moderate dose range of 9 to 19 microg/kg (mean 14 microg/kg), provides safe and effective postoperative analgesia in the

  3. Intrathecal Administration of Morphine Decreases Persistent Pain after Cesarean Section: A Prospective Observational Study.

    Directory of Open Access Journals (Sweden)

    Kumi Moriyama

    Full Text Available Chronic pain after cesarean section (CS is a serious concern, as it can result in functional disability. We evaluated the prevalence of chronic pain after CS prospectively at a single institution in Japan. We also analyzed perioperative risk factors associated with chronic pain using logistic regression analyses with a backward-stepwise procedure.Patients who underwent elective or emergency CS between May 2012 and May 2014 were recruited. Maternal demographics as well as details of surgery and anesthesia were recorded. An anesthesiologist visited the patients on postoperative day (POD 1 and 2, and assessed their pain with the Prince Henry Pain Scale. To evaluate the prevalence of chronic pain, we contacted patients by sending a questionnaire 3 months post-CS.Among 225 patients who questionnaires, 69 (30.7% of patients complained of persistent pain, although no patient required pain medication. Multivariate analyses identified lighter weight (p = 0.011 and non-intrathecal administration of morphine (p = 0.023 as determinant factors associated with persistent pain at 3 months. The adjusted odds ratio of intrathecal administration of morphine to reduce persistent pain was 0.424, suggesting that intrathecal administration of morphine could decrease chronic pain by 50%. In addition, 51.6% of patients had abnormal wound sensation, suggesting the development of neuropathic pain. Also, 6% of patients with abnormal wound sensation required medication, yet no patients with persistent pain required medication.Although no effect on acute pain was observed, intrathecal administration of morphine significantly decreased chronic pain after CS.

  4. Abdominal girth and vertebral column length aid in predicting intrathecal hyperbaric bupivacaine dose for elective cesarean section.

    Science.gov (United States)

    Wei, Chang-Na; Zhou, Qing-He; Wang, Li-Zhong

    2017-08-01

    Currently, there is no consensus on how to determine the optimal dose of intrathecal bupivacaine for an individual undergoing an elective cesarean section. In this study, we developed a regression equation between intrathecal 0.5% hyperbaric bupivacaine volume and abdominal girth and vertebral column length, to determine a suitable block level (T5) for elective cesarean section patients.In phase I, we analyzed 374 parturients undergoing an elective cesarean section that received a suitable dose of intrathecal 0.5% hyperbaric bupivacaine after a combined spinal-epidural (CSE) was performed at the L3/4 interspace. Parturients with T5 blockade to pinprick were selected for establishing the regression equation between 0.5% hyperbaric bupivacaine volume and vertebral column length and abdominal girth. Six parturient and neonatal variables, intrathecal 0.5% hyperbaric bupivacaine volume, and spinal anesthesia spread were recorded. Bivariate line correlation analyses, multiple line regression analyses, and 2-tailed t tests or chi-square test were performed, as appropriate. In phase II, another 200 parturients with CSE for elective cesarean section were enrolled to verify the accuracy of the regression equation.In phase I, a total of 143 parturients were selected to establish the following regression equation: YT5 = 0.074X1 - 0.022X2 - 0.017 (YT5 = 0.5% hyperbaric bupivacaine volume for T5 block level; X1 = vertebral column length; and X2 = abdominal girth). In phase II, a total of 189 participants were enrolled in the study to verify the accuracy of the regression equation, and 155 parturients with T5 blockade were deemed eligible, which accounted for 82.01% of all participants.This study evaluated parturients with T5 blockade to pinprick after a CSE for elective cesarean section to establish a regression equation between parturient vertebral column length and abdominal girth and 0.5% hyperbaric intrathecal bupivacaine volume. This equation can accurately

  5. Active implants and scaffolds for tissue regeneration

    CERN Document Server

    Zilberman, Meital

    2011-01-01

    Active implants are actually drug or protein-eluting implants that induce healing effects, in addition to their regular task, such as support. This book gives a broad overview of biomaterial platforms used as basic elements of drug-eluting implants.

  6. Intrathecal application of autologous bone marrow cell preparations in parkinsonian syndromes

    DEFF Research Database (Denmark)

    Storch, Alexander; Csoti, Ilona; Eggert, Karla

    2012-01-01

    A growing number of patients is treated with intrathecal application of autologous bone marrow cells (aBMCs), but clinical data are completely lacking in movement disorders. We provide first clinical data on efficacy and safety of this highly experimental treatment approach in parkinsonian...

  7. Efficacy of a Targeted Drug Delivery on-Demand Bolus Option for Chronic Pain.

    Science.gov (United States)

    Bolash, Robert B; Niazi, Tariq; Kumari, Meera; Azer, Gerges; Mekhail, Nagy

    2018-03-01

    Intrathecal targeted drug delivery systems historically required physician office visits for dose adjustment to manage fluctuating pain. A wireless device now enables patients to supplement their basal intrathecal infusion with a programmed on-demand bolus dose. We sought to quantify the change in oral breakthrough opioid need associated with the use of an intrathecal bolus in comparison to those treated with the basal infusion alone. Demographic, dosage, bolus usage and longevity data were extracted from the historical medical record of 69 patients (18/51 bolus/nonbolus) followed continuously at our center. Medication consumption and Pain Disability Index measures were obtained at baseline and most recent follow-up. Among patients with the bolus option, only 2 (11%; confidence interval [CI] 0% to 26%) continued to require oral opiates to manage breakthrough pain compared to 29 (57%; CI 43% to 71%) without the bolus option. The Pain Disability Index score decreased by 19% in patients with the bolus option and by 25% in those with the basal infusion. Total daily intrathecal opioid intake was 34% lower in the group with the bolus device. Utilizing an intrathecal bolus to treat incident pain was a safe way to manage unpredictable breakthrough pain and may represent a cost-saving opportunity by eliminating the need for oral analgesic medications. © 2017 World Institute of Pain.

  8. Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho

    2011-01-01

    The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of 98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Intrathecal morphine is superior to intravenous PCA in patients undergoing minimally invasive cardiac surgery

    Directory of Open Access Journals (Sweden)

    Chirojit Mukherjee

    2012-01-01

    Full Text Available Aim of our study was to evaluate the beneficial effect of low dose intrathecal morphine on postoperative analgesia, over the use of intravenous patient controlled anesthesia (PCA, in patients undergoing fast track anesthesia during minimally invasive cardiac surgical procedures. A randomized controlled trial was undertaken after approval from local ethical committee. Written informed consent was obtained from 61 patients receiving mitral or tricuspid or both surgical valve repair in minimal invasive technique. Patients were assigned randomly to 2 groups. Group 1 received general anesthesia and intravenous patient controlled analgesia (PCA pump with Piritramide (GA group. Group 2 received a single shot of intrathecal morphine (1.5 μg/kg body weight prior to the administration of general anesthesia (ITM group. Site of puncture was confined to lumbar (L1-2 or L2-3 intrathecal space. The amount of intravenous piritramide used in post anesthesia care unit (PACU and the first postoperative day was defined as primary end point. Secondary end points included: time for tracheal extubation, pain and sedation scores in PACU upto third postoperative day. For statistical analysis Mann-Whitney-U Test and Fishers exact test (SPSS were used. We found that the demand for intravenous opioids in PACU was significantly reduced in ITM group (P <0.001. Pain scores were significantly decreased in ITM group until second postoperative day (P <0.01. There was no time delay for tracheal extubation in ITM group, and sedation scores did not differ in either group. We conclude that low dose single shot intrathecal morphine provides adequate postoperative analgesia, reduces the intravenous opioid consumption during the early postoperative period and does not defer early extubation.

  10. Improved design and characterization of PLGA/PLA-coated Chitosan based micro-implants for controlled release of hydrophilic drugs.

    Science.gov (United States)

    Manna, Soumyarwit; Donnell, Anna M; Kaval, Necati; Al-Rjoub, Marwan F; Augsburger, James J; Banerjee, Rupak K

    2018-05-29

    Repetitive intravitreal injections of Methotrexate (MTX), a hydrophilic chemotherapeutic drug, are currently used to treat selected vitreoretinal (VR) diseases, such as intraocular lymphoma. To avoid complications associated with the rapid release of MTX from the injections, a Polylactic acid (PLA) and Chitosan (CS)-based MTX micro-implant prototype was fabricated in an earlier study, which showed a sustained therapeutic release rate of 0.2-2.0 µg/day of MTX for a period ∼1 month in vitro and in vivo. In the current study, different combinations of Poly(lactic-co-glycolic) acid (PLGA)/PLA coatings were used for lipophilic surface modification of the CS-MTX micro-implant, such as PLGA 5050, PLGA 6535 and PLGA 7525 (PLA: PGA - 50:50, 65:35, 75:25, respectively; M.W: 54,400 - 103,000) and different PLA, such as PLA 100 and PLA 250 (MW: 102,000 and 257,000, respectively). This improved the duration of total MTX release from the coated CS-MTX micro-implants to ∼3-5 months. With an increase in PLA content in PLGA and molecular weight of PLA, a) the initial burst of MTX and the mean release rate of MTX can be reduced; and b) the swelling and biodegradation of the micro-implants can be delayed. The controlled drug release mechanism is caused by a combination of diffusion process and hydrolysis of the polymer coating, which can be modulated by a) PLA content in PLGA and b) molecular weight of PLA, as inferred from Korsmeyer Peppas model, Zero order, First order and Higuchi model fits. This improved micro-implant formulation has the potential to serve as a platform for controlled release of hydrophilic drugs to treat selected VR diseases. Copyright © 2018. Published by Elsevier B.V.

  11. Complete response in HER2+ leptomeningeal carcinomatosis from breast cancer with intrathecal trastuzumab.

    Science.gov (United States)

    Oliveira, Mafalda; Braga, Sofia; Passos-Coelho, José Luís; Fonseca, Ricardo; Oliveira, João

    2011-06-01

    Trastuzumab, a monoclonal antibody against the HER2 receptor, is a major breakthrough in the treatment of HER2+ breast cancer. However, its high molecular weight precludes it from crossing the intact blood-brain barrier, making the central nervous system a sanctuary to HER2+ breast cancer metastases. We prospectively assessed functional outcome and toxicity of administering trastuzumab directly into the cerebrospinal fluid of a patient with leptomeningeal carcinomatosis (LC) and brain metastases from HER2+ breast cancer that had already been treated with other intrathecal chemotherapy, with no benefit. Upon signed informed consent, weekly lumbar puncture with administration of trastuzumab 25 mg was begun to a 44 year-old women with metastatic breast cancer (lymph node, bone, lung, and liver involvement) previously treated with tamoxifen, letrozole, anthracyclines, taxanes, capecitabine, intravenous trastuzumab, and lapatinib. She received 67 weekly administrations of intrathecal trastuzumab with marked clinical improvement and no adverse events. She survived 27 months after LC diagnosis. A complete leptomeningeal response, with no evidence of leptomeningeal metastasis at necropsy, was achieved. We believe that intrathecal trastuzumab administration should be prospectively evaluated to confirm clinical activity and optimize dose, schedule, and duration of treatment.

  12. Cautious Use of Intrathecal Baclofen in Walking Spastic Patients: Results on Long-term Follow-up.

    Science.gov (United States)

    Dones, Ivano; Nazzi, Vittoria; Tringali, Giovanni; Broggi, Giovanni

    2006-04-01

    Intrathecal baclofen is presently the most effective treatment for diffuse spasticity whatever the cause. The fact that both spasticity is always accompanied by a degree of muscle weakness and that any antispastic treatment causes a decrease in muscle strength indicate that major attention must be paid in treating spasticity in ambulant patients. Methods.  We present here a retrospective study, approved by the insitutional ethics committee, of 22 ambulant spastic patients, selected as homogeneous for disease and disease duration, who were treated with intrathecal baclofen at the Istituto Nazionale Neurologico "C.Besta" in Milan. These patients were followed-up for to 15 years of treatment and their clinical assessment was enriched by the evaluation of their functional independence measurement (FIM) before and during treatment. Results.  There was improvement in quality of life as measured by the FIM scale; however, an increase in the patient's motor performance could not be detected. Conclusion.  Although we did not show any improvement in muscle performance, intrathecal baclofen did improve daily quality of life, even in spastic patients who were able to walk.

  13. Prilocaine hydrochloride 2% hyperbaric solution for intrathecal injection: a clinical review

    Directory of Open Access Journals (Sweden)

    Manassero A

    2017-03-01

    Full Text Available Alberto Manassero,1 Andrea Fanelli2 1Department of Emergency and Critical Care, Anesthesia and Intensive Care Unit, S. Croce e Carle Hospital, Cuneo, 2Department of Medical and Surgical Sciences, Anesthesia and Intensive Care Unit, Policlinico S. Orsola-Malpighi, Bologna, Italy Abstract: Prilocaine is a local anesthetic characterized by intermediate potency and duration and fast onset of action. As hyperbaric formulation of 5% solution, it was introduced and has been successfully used for spinal anesthesia since 1960. A new formulation of 2% plain and hyperbaric solution is currently available in Europe. Because of its lower incidence of transient neurological symptoms, prilocaine is suggested as substitute to lidocaine and mepivacaine in spinal anesthesia for ambulatory surgery, as well as a suitable alternative to low doses of long-acting local anesthetics. The National Library of Medicine database, the Excerpta Medica database, the Cochrane Database of Systematic Reviews, and the Cochrane Central Register of Controlled Trials database, were searched for the period 1970 to September 2016, with the aim to identify studies evaluating the intrathecal use of 2% prilocaine. A total of 13 randomized clinical trials (RCTs, 1 observational study, 2 dose finding, and 4 systematic reviews has been used for this review. The studies evaluated showed that 2% hyperbaric prilocaine due to a favorable anesthetic and safety profile is an alternative drug to lidocaine and mepivacaine for spinal anesthesia of intermediate or short duration. In comparison with plain solutions, hyperbaricity remarkably accelerates the onset and offset times of intrathecal 2% prilocaine. Literature suggests a dose ranging between 40 and 60 mg of prilocaine for lower extremities and lower abdominal procedures lasting up to 90 min, whereas a dose ranging from 10 to 30 mg is appropriate for perineal surgery. Readiness for discharge occurs in ~4 h from spinal administration. Keywords

  14. The effects of intrathecal midazolam on the duration of analgesia in ...

    African Journals Online (AJOL)

    This study was designed to evaluate the effect of 2 mg preservative-free intrathecal midazolam added to spinal bupivacaine during postoperative analgesia, and the incidence of adverse effects, if any, in patients undergoing knee arthroscopies. Method: Fifty consenting American Society of Anesthesiologists (ASA) physical ...

  15. Intrathecal pressure monitoring and cerebrospinal fluid drainage in acute spinal cord injury: a prospective randomized trial.

    Science.gov (United States)

    Kwon, Brian K; Curt, Armin; Belanger, Lise M; Bernardo, Arlene; Chan, Donna; Markez, John A; Gorelik, Stephen; Slobogean, Gerard P; Umedaly, Hamed; Giffin, Mitch; Nikolakis, Michael A; Street, John; Boyd, Michael C; Paquette, Scott; Fisher, Charles G; Dvorak, Marcel F

    2009-03-01

    Ischemia is an important factor in the pathophysiology of secondary damage after traumatic spinal cord injury (SCI) and, in the setting of thoracoabdominal aortic aneurysm repair, can be the primary cause of paralysis. Lowering the intrathecal pressure (ITP) by draining CSF is routinely done in thoracoabdominal aortic aneurysm surgery but has not been evaluated in the setting of acute traumatic SCI. Additionally, while much attention is directed toward maintaining an adequate mean arterial blood pressure (MABP) in the acute postinjury phase, little is known about what is happening to the ITP during this period when spinal cord perfusion pressure (MABP - ITP) is important. The objectives of this study were to: 1) evaluate the safety and feasibility of draining CSF to lower ITP after acute traumatic SCI; 2) evaluate changes in ITP before and after surgical decompression; and 3) measure neurological recovery in relation to the drainage of CSF. Twenty-two patients seen within 48 hours of injury were prospectively randomized to a drainage or no-drainage treatment group. In all cases a lumbar intrathecal catheter was inserted for 72 hours. Acute complications of headache/nausea/vomiting, meningitis, or neurological deterioration were carefully monitored. Acute Spinal Cord Injury motor scores were documented at baseline and at 6 months postinjury. On insertion of the catheter, mean ITP was 13.8 +/- 1.3 mm Hg (+/- SD), and it increased to a mean peak of 21.7 +/- 1.5 mm Hg intraoperatively. The difference between the starting ITP on catheter insertion and the observed peak intrathecal pressure after decompression was, on average, an increase of 7.9 +/- 1.6 mm Hg (p drainage group was 30.6 +/- 2.3 mm Hg, which was significantly higher than the peak intraoperative ITP (p = 0.0098). During the same period, the peak recorded ITP in patients randomized to receive drainage was 28.1 +/- 2.8 mm Hg, which was not statistically higher than the peak intraoperative ITP (p = 0.15). The

  16. Treatment of neuropathic cancer pain with continuous intrathecal administration of S (+)-ketamine

    NARCIS (Netherlands)

    Vranken, J. H.; van der Vegt, M. H.; Kal, J. E.; Kruis, M. R.

    2004-01-01

    The effective treatment of patients suffering from neuropathic cancer pain remains a clinical challenge. When patients experience either insufficient analgesia or problematic side-effects after opioid administration, intrathecal administration of morphine and other medications such as bupivacaine

  17. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  18. Sonographic evaluation of epidural and intrathecal injections in cats.

    Science.gov (United States)

    Otero, Pablo E; Verdier, Natali; Zaccagnini, Andrea S; Fuensalida, Santiago E; Sclocco, Matias; Portela, Diego A; Waxman, Samanta

    2016-11-01

    To describe the ultrasonographic anatomy of the caudal lumbar spine in cats and to detect ultrasound (US) signs associated with epidural or intrathecal injection. Prospective, clinical study. Twenty-six client-owned cats. Transverse (position 1) and parasagittal (position 2) two-dimensional US scanning was performed over the caudal lumbar spine in all cats. Midline distances between the identified structures were measured. Cats assigned to epidural injection (group E, n = 16) were administered a bupivacaine-morphine combination confirmed by electrical stimulation. Cats assigned to intrathecal injection (group I, n = 10) were administered a morphine-iohexol combination injected at the lumbosacral level and confirmed by lateral radiography. The total volume injected (0.3 mL kg -1 ) was divided into two equal aliquots that were injected without needle repositioning, with the US probe in positions 1 and 2, respectively. The presence or absence of a burst of color [color flow Doppler test (CFDT)], dural sac collapse and epidural space enlargement were registered during and after both injections. US scanning allowed measurement of the distances between the highly visible structures inside the spinal canal. CFDT was positive for all animals in group E. In group I, intrathecal injection was confirmed in only two animals, for which the CFDT was negative; seven cats inadvertently and simultaneously were administered an epidural injection and showed a positive CFDT during the second aliquot injection, and the remaining animal was administered epidural anesthesia and was excluded from the CFDT data analysis. Dural sac collapse and epidural space enlargement were present in all animals in which an epidural injection was confirmed. US examination allowed an anatomical description of the caudal lumbar spine and real-time confirmation of epidural injection by observation of a positive CFDT, dural sac collapse and epidural space enlargement. © 2016 Association of Veterinary

  19. Repair of spinal cord injury by implantation of bFGF-incorporated HEMA-MOETACL hydrogel in rats

    Science.gov (United States)

    Chen, Bo; He, Jianyu; Yang, Hao; Zhang, Qian; Zhang, Lingling; Zhang, Xian; Xie, En; Liu, Cuicui; Zhang, Rui; Wang, Yi; Huang, Linhong; Hao, Dingjun

    2015-03-01

    There is no effective strategy for the treatment of spinal cord injury (SCI). An appropriate combination of hydrogel materials and neurotrophic factor therapy is currently thought to be a promising approach. In this study, we performed experiments to evaluate the synergic effect of implanting hydroxyl ethyl methacrylate [2-(methacryloyloxy)ethyl] trimethylammonium chloride (HEMA-MOETACL) hydrogel incorporated with basic fibroblast growth factor (bFGF) into the site of surgically induced SCI. Prior to implantation, the combined hydrogel was surrounded by an acellular vascular matrix. Sprague-Dawley rats underwent complete spinal cord transection at the T-9 level, followed by implantation of bFGF/HEMA-MOETACL 5 days after transection surgery. Our results showed that the bFGF/HEMA-MOETACL transplant provided a scaffold for the ingrowth of regenerating tissue eight weeks after implantation. Furthermore, this newly designed implant promoted both nerve tissue regeneration and functional recovery following SCI. These results indicate that HEMA-MOETACL hydrogel is a promising scaffold for intrathecal, localized and sustained delivery of bFGF to the injured spinal cord and provide evidence for the possibility that this approach may have clinical applications in the treatment of SCI.

  20. The analgesic effects of intrathecal xylazine and detomidine in sheep and their antagonism with systemic atipamezole.

    Science.gov (United States)

    Christina Haerdi-Landerer, M; Schlegel, Urs; Neiger-Aeschbacher, Gina

    2005-09-01

    To evaluate the analgesic and adverse side effects of intrathecal (IT) xylazine (XYL) and detomidine (DET) and the subsequent effects of two doses of intravenous (IV) atipamezole (ATI). Prospective, randomized, cross-over. Five adult healthy female sheep with mean body mass of 55 +/- 2.3 kg. Material and methods Each sheep underwent four treatments: 1) 50 microg kg(-1) XYL IT and 5 microg kg(-1) ATI IV, 2) 50 microg kg(-1) XYL IT and 2.5 microg kg(-1) ATI IV, 3) 10 microg kg(-1) DET IT and 5 microg kg(-1) ATI IV, 4) 10 microg kg(-1) DET IT and 2.5 microg kg(-1) ATI IV. Pain threshold (TH) was tested by applying pulsed and stepwise incremental direct current to the skin overlying the pastern. The current at the point of foot lift was recorded as the TH. Heart rate (HR), mean arterial pressure, arterial oxygen (PO(2)) and carbon dioxide (PCO(2)) tensions were monitored. Outcomes were derived as differences between baseline assessment and measurements after treatment. Two-way anova was used to analyse drug effects, treatment differences between groups were examined with an F-test or Wilcoxon's rank sum test in case of non-parametric data distribution. p was set at 0.05. Both drugs increased the pain TH, caused small increases in PCO(2), and small decreases in HR, the latter was only significant for XYL recipients. Xylazine produced a significantly higher TH, more rapidly and for longer than DET. Atipamezole only significantly affected PaCO(2) in the XYL group 2. The pain TH was not affected in either group after IV ATI. At the doses used, IT XYL, and to a lesser extent DET, induced pastern analgesia. Atipamezole 5 microg kg(-1) IV antagonized some side effects without affecting analgesia. Intrathecal XYL may be useful as an analgesic in sheep. Its safety is increased because IV ATI antagonizes side effects, but not analgesia.

  1. The effects of intrathecal administration of betamethasone over the dogs' spinal cord and meninges.

    Science.gov (United States)

    Barros, Guilherme Antonio Moreira de; Marques, Mariângela Esther Alencar; Ganem, Eliana Marisa

    2007-01-01

    To determinate the potential clinical and histological changes due the injection of betamethasone, when administered into the canine intrathecal space. Twenty one animals were included in a random and blind manner in the study. After general anesthesia, intrathecal puncture was performed and 1 ml of the random solution was injected. The G1 dogs received 0.9% saline solution, the G2 dogs received 1.75 mg betamethasone and the G3 dogs received 3.5 mg of betamethasone. The animals were clinically evaluated for 21 days and then sacrificed. The lumbar and sacral portions of the spinal cord were removed for light microscopy histological analyses. No clinical changes were observed in any of the animals included in this study. No histological changes were observed in G1 animals. Inflammatory infiltration was observed in two dogs, one in G2, another in G3. Hemorrhage and necrosis were also seen in the G2 dog which inflammatory infiltration was detected. In other two dogs, one from G2 and another from G3, there was discreet fibrosis and thickness of the arachnoid layer which was focal in one and diffuse in the other. Intrathecal administration of betamethasone caused histological changes in the spinal cord and meninges in some of the dogs involved in this study.

  2. Perioperative analgesia after intrathecal fentanyl and morphine or morphine alone for cesarean section: A randomized controlled study.

    Science.gov (United States)

    Weigl, Wojciech; Bieryło, Andrzej; Wielgus, Monika; Krzemień-Wiczyńska, Świetlana; Kołacz, Marcin; Dąbrowski, Michał J

    2017-12-01

    Intrathecal morphine is used in the postoperative management of pain after caesarean section (CS), but might not be optimal for intraoperative analgesia. We hypothesized that intrathecal fentanyl could supplement intraoperative analgesia when added to a local anesthetic and morphine without affecting management of postoperative pain. This prospective, randomized, double-blind, parallel-group study included 60 parturients scheduled for elective CS. Spinal anesthesia consisted of bupivacaine with either morphine 100 μg (M group), or fentanyl 25 μg and morphine 100 μg (FM group). The frequency of intraoperative pain and pethidine consumption in the 24 hours postoperatively was recorded. Fewer patients in the FM group required additional intraoperative analgesia (P fentanyl and morphine may provide better perioperative analgesia than morphine alone in CS and could be useful when the time from anesthesia to skin incision is short. However, an increase in PONV and possible acute spinal opioid tolerance after addition of intrathecal fentanyl warrants further investigation using lower doses of fentanyl.

  3. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 3-year follow-up of the randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) Trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Thuesen, Leif

    2010-01-01

    The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI)....

  4. Fast Track Liver Resection: The Effect of a Comprehensive Care Package and Analgesia with Single Dose Intrathecal Morphine with Gabapentin or Continuous Epidural Analgesia

    Directory of Open Access Journals (Sweden)

    Jonathan B. Koea

    2009-01-01

    Full Text Available Background. A comprehensive care package for patients undergoing hepatectomy was developed with the aim of minimal physiological disturbance in the peri-operative period. Peri-operative analgesia with few gastrointestinal effects and reduced requirement for intravenous (IV fluid therapy was central to this plan. Methods. Data on 100 consecutive patients managed with continuous epidural infusion (n = 50; bupivicaine 0.125% and fentanyl 2 g/mL at 0.1 mL/kg/hr or intrathecal morphine (n = 50; 300 g in combination with oral gabapentin 1200 mg preoperatively and 400 mg bd postoperatively was compared. Results. The epidural and intrathecal morphine groups were equivalent in terms of patient demographics, procedures and complications. Patients receiving intrathecal morphine received less intra-operative IV fluids (median 1500 mL versus 2200 mL, =.06, less postoperative IV fluids (median 1200 mL versus 4300 mL, =.03 than patients receiving epidural infusion. Patients managed with intrathecal morphine established a normal dietary intake sooner (16 hours versus 20 hours, =.05 and had shorter hospital stays than those managed with epidural infusions (4.7 ± 0.9 days versus 6.8 ± 1.2 days, =.02. Conclusions. Single dose intrathecal morphine is a safe and effective means of providing peri-operative analgesia. Patients managed with intrathecal morphine have reduced peri-operative physiological disturbance and return home within a few days of hepatic resection.

  5. Positive experience with intrathecal baclofen treatment in children with severe cerebral palsy

    DEFF Research Database (Denmark)

    Overgård, Tinett Martesen; Kjærsgaard-Hansen, Lars; Søe, Morten

    2015-01-01

    INTRODUCTION: Treatment of severe spasticity and dystonia with intrathecal baclofen (ITB) in children has been shown to be effective and has therefore been employed in the Region of Southern Denmark. The aim of this retrospective study was to analyse the efficacy and adverse events since ITB was ...

  6. Prolonged Survival of Acute Lymphoblastic Leukemia with Intrathecal Treatments for Isolated Central Nervous System Relapse

    Directory of Open Access Journals (Sweden)

    Elan Gorshein

    2018-01-01

    Full Text Available Acute lymphoblastic leukemia is commonly cured when diagnosed in the pediatric population. It portends a poorer prognosis if present in adult patients. Although adults frequently achieve complete remission, relapse rates are substantial, particularly among the elderly and high-risk populations. In the absence of prophylactic intrathecal chemotherapy, more than half of patients may develop CNS involvement or relapse, which is associated with significant risk for systemic illness. This report describes a patient with acute lymphoblastic leukemia with repeated isolated CNS relapses. This case should remind clinicians that isolated CNS disease in the absence of systemic recurrence could successfully respond to intrathecal therapy and offer patients a favorable quality of life.

  7. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  8. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Radu, Maria D; Räber, Lorenz; Heo, Jungho

    2014-01-01

    history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS...

  9. Low intrathecal antibody production despite high seroprevalence of Epstein-Barr virus in multiple sclerosis: a review of the literature.

    Science.gov (United States)

    Ruprecht, Klemens; Wildemann, Brigitte; Jarius, Sven

    2018-02-01

    Patients with multiple sclerosis (MS) frequently have an intrathecal production of antibodies to different common viruses, which can be detected by elevated antiviral antibody indices (AIs). There is a strong and consistent association of MS and Epstein-Barr virus (EBV) infection. To systematically compare the frequencies of intrathecal antibody production to EBV, measles virus, rubella virus, varicella zoster virus (VZV) and herpes simplex virus (HSV) in patients with MS. Review of the English and German literature on the frequencies of intrathecal immunoglobulin (Ig)G antibody production, as defined by an elevated AI, to EBV, measles virus, rubella virus, VZV and HSV in adult and pediatric patients with MS. In nine original studies identified, the frequencies of an intrathecal production of antibodies to Epstein-Barr nuclear antigen-1 (33/340, 9.7%), EBV viral capsid antigen (12/279, 4.3%) and antigens from EBV-infected cell lines (14/90, 15.6%) in adult patients with MS were clearly lower (p ≤ 0.03 for all pairwise comparisons) than the frequencies of an intrathecal production of antibodies to measles virus (612/922, 66.4%), rubella virus (521/922, 56.5%), VZV (470/922, 51%; data from 17 original studies) and HSV (78/291, 26.8%; data from 6 original studies). Though based on a lower number of original studies and patients, findings in children with MS were essentially similar. As in adults and children with MS the seroprevalence of EBV is higher than the seroprevalences of the other investigated viruses, the lower frequency of elevated EBV AIs became even more pronounced after correction of the frequencies of elevated antiviral AIs for the seroprevalences of the respective viruses. Given the very high seroprevalence of EBV in MS, the frequency of intrathecally produced antibodies to EBV in patients with MS is paradoxically low compared to that of other common viruses. These findings are compatible with the recently proposed hypothesis that in individuals

  10. 21 CFR 870.3610 - Implantable pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable pacemaker pulse generator. 870.3610 Section 870.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has...

  11. Intrathecal isobaric versus hyperbaric bupivacaine for elective caesarean section

    International Nuclear Information System (INIS)

    Aftab, S.; Ali, H.; Zafar, S.; Sheikh, M.; Sultan, T.

    2007-01-01

    To compare the results of isobaric bupivacaine (0.5%) with hyperbaric bupivacaine (0.75%) in cases of elective Caesarean Section, in respect of time to sensory analgesia, highest level of sensory block, haemodynamic effects, and complications. Sixty pregnant patients scheduled for elective Caesarean Section. The patients were randomly assigned to receive either 0.5% isobaric bupivacaine (Group-1B) or 0.75% hyperbaric bupivacaine (Group-HB) via intrathecal route. The time of onset of block, highest level of sensory block, cardio-respiratory data, duration of analgesia and complications were recorded during surgery. The time taken to reach T4 sensory analgesia in Group-1B was 6+-6.43 minutes as compared to 6.93+-7.8 minutes in Group-HB, while the highest sensory level achieved in Group-1B was T1 and in Group-HB T2. The lowest systolic blood pressure recorded in Group-1B was 83.27+-12.69 mmHg and in Group-HB 114.33+-13.83 mm Hg, the difference being significant (p<0.05). There was a higher incidence of complications in Group-1B as compared to Group-HB like high spinal analgesia, vomiting and discomfort. Intrathecal block showed a greater reduction in the systolic blood pressure, and associated complications, with Isobaric Bupivacaine as compared to Hyperbaric Bupivacaine. (author)

  12. Liposomal Cytarabine Induces Less Neurocognitive Dysfunction Than Intrathecal Methotrexate in an Animal Model

    DEFF Research Database (Denmark)

    Thomsen, Anna M; Gulinello, Maria E; Wen, Jing

    2018-01-01

    Liposomal cytarabine is currently being tested clinically as an alternative to intrathecal (IT) methotrexate (MTX) for preventing relapse within the central nervous system among patients with acute lymphoblastic leukemia. To compare the toxicity and cognitive deficits caused by IT MTX versus lipo...

  13. Progressive increase in brain glucose metabolism after intrathecal administration of autologous mesenchymal stromal cells in patients with diffuse axonal injury.

    Science.gov (United States)

    Vaquero, Jesús; Zurita, Mercedes; Bonilla, Celia; Fernández, Cecilia; Rubio, Juan J; Mucientes, Jorge; Rodriguez, Begoña; Blanco, Edelio; Donis, Luis

    2017-01-01

    Cell therapy in neurological disability after traumatic brain injury (TBI) is in its initial clinical stage. We describe our preliminary clinical experience with three patients with diffuse axonal injury (DAI) who were treated with intrathecal administration of autologous mesenchymal stromal cells (MSCs). Three patients with established neurological sequelae due to DAI received intrathecally autologous MSCs. The total number of MSCs administered was 60 × 10 6 (one patient), 100 × 10 6 (one patient) and 300 × 10 6 (one patient). All three patients showed improvement after cell therapy, and subsequent studies with 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) showed a diffuse and progressive increase in brain glucose metabolism. Our present results suggest benefit of intrathecal administration of MSCs in patients with DAI, as well as a relationship between this type of treatment and increase in brain glucose metabolism. These preliminary findings raise the question of convenience of assessing the potential benefit of intrathecal administration of MSCs for brain diseases in which a decrease in glucose metabolism represents a crucial pathophysiological finding, such as Alzheimer's disease (AD) and other dementias. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  14. Autologous Bone Marrow Mononuclear Cells Intrathecal Transplantation in Chronic Stroke

    Directory of Open Access Journals (Sweden)

    Alok Sharma

    2014-01-01

    Full Text Available Cell therapy is being widely explored in the management of stroke and has demonstrated great potential. It has been shown to assist in the remodeling of the central nervous system by inducing neurorestorative effect through the process of angiogenesis, neurogenesis, and reduction of glial scar formation. In this study, the effect of intrathecal administration of autologous bone marrow mononuclear cells (BMMNCs is analyzed on the recovery process of patients with chronic stroke. 24 patients diagnosed with chronic stroke were administered cell therapy, followed by multidisciplinary neurorehabilitation. They were assessed on functional independence measure (FIM objectively, along with assessment of standing and walking balance, ambulation, and hand functions. Out of 24 patients, 12 improved in ambulation, 10 in hand functions, 6 in standing balance, and 9 in walking balance. Further factor analysis was done. Patients of the younger groups showed higher percentage of improvement in all the areas. Patients who underwent cell therapy within 2 years after the stroke showed better changes. Ischemic type of stroke had better recovery than the hemorrhagic stroke. This study demonstrates the potential of autologous BMMNCs intrathecal transplantation in improving the prognosis of functional recovery in chronic stage of stroke. Further clinical trials are recommended. This trial is registered with NCT02065778.

  15. COMBINED SPINAL EPIDURAL ANALGESIA IN LABOUR: COMPARISON OF BUPIVACAINE 1.25 MG WITH FENTANYL AND ROPIVACAINE 2.5 MG WITH FENTANYL INTRATHECAL

    Directory of Open Access Journals (Sweden)

    Prakash T. S. N

    2016-10-01

    with ASA I and ASA II in established labour with cervical dilatation less than 5 cm was selected and randomly allocated into two groups using closed envelope method. Informed written consent was taken from all participants. They were divided into 2 groups of 20 each. Group I received intrathecal Inj. Bupivacaine 1.25 mg and Inj. Fentanyl 20 µg. Group II received intrathecal Inj. Ropivacaine 2.5 mg and Inj. Fentanyl 20 µg for combined spinal epidural. IV line was secured with 18G cannula. Patient was preloaded with 500 mL of Hartmann’s solution. Basal vital parameter like pulse rate, blood pressure, respiration, O2 saturation were recorded. The patient was positioned in a sitting position with the help of an assistant. Under aseptic conditions, the back was prepared with 5% povidone-iodine solution, spirit and area was draped. L3-L4 interspace was identified. Skin was infiltrated with 2 mL of 1% Xylocaine. After infiltration of local anaesthetic by using needle through needle technique 18-gauge Tuohy needle, epidural space was identified with loss of resistance to air technique. Then, a 15 mm (27 G long ‘Whitacre’ spinal needle was introduced through the epidural needle and the correct position of the tip in the intrathecal space was confirmed by observation of free flow of CSF. Patients were allocated randomly to receive intrathecal injection of bupivacaine 1.25 mg (0.5% bupivacaine 0.25 mL with fentanyl 20 µg (Group I n=30 or ropivacaine 2.5 mg/0.2% ropivacaine 1.25 mL with fentanyl 20 µg (Group II, n=30 both made up to total volume of 2 mL with saline. Injection of intrathecal drug was completed in 10 secs., then 20G epidural catheter was threaded through the epidural needle into the epidural space in cephalad direction. The epidural needle was slowly pulled out without disturbing the catheter. About 3 to 5 cm of catheter was left in epidural space. The catheter was well secured with plaster. Patients vitals was recorded every 5, 10, 15, 30, 45, 60, 75, 90

  16. Electrophysiologic Study of a Method of Euthanasia Using Intrathecal Lidocaine Hydrochloride Administered during Intravenous Anesthesia in Horses.

    Science.gov (United States)

    Aleman, M; Davis, E; Williams, D C; Madigan, J E; Smith, F; Guedes, A

    2015-01-01

    An intravenous (IV) overdose of pentobarbital sodium is the most commonly used method of euthanasia in veterinary medicine. However, this compound is not available in many countries or rural areas resulting in usage of alternative methods such as intrathecal lidocaine administration after IV anesthesia. Its safety and efficacy as a method of euthanasia have not been investigated in the horse. To investigate changes in mean arterial blood pressure and electrical activity of the cerebral cortex, brainstem, and heart during intrathecal administration of lidocaine. Our hypothesis was that intrathecal lidocaine affects the cerebral cortex and brainstem before affecting cardiovascular function. Eleven horses requiring euthanasia for medical reasons. Prospective observational study. Horses were anesthetized with xylazine, midazolam, and ketamine; and instrumented for recording of electroencephalogram (EEG), electrooculogram (EOG), brainstem auditory evoked response (BAER), and electrocardiogram (ECG). Physical and neurological (brainstem reflexes) variables were monitored. Mean arterial blood pressure was recorded throughout the study. Loss of cerebro-cortical electrical activity occurred up to 226 seconds after the end of the infusion of lidocaine solution. Cessation of brainstem function as evidenced by a lack of brainstem reflexes and disappearance of BAER occurred subsequently. Undetectable heart sounds, nonpalpable arterial pulse, and extremely low mean arterial blood pressure supported cardiac death; a recordable ECG was the last variable to disappear after the infusion (300-1,279 seconds). Intrathecal administration of lidocaine is an effective alternative method of euthanasia in anesthetized horses, during which brain death occurs before cardiac death. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  17. Intrathecal administration of clonidine or yohimbine decreases the nociceptive behavior caused by formalin injection in the marsh terrapin (Pelomedusa subrufa)

    DEFF Research Database (Denmark)

    Makau, Christopher M; Towett, Philemon K; Abelson, Klas S P

    2014-01-01

    BACKGROUND: The role of noradrenergic system in the control of nociception is documented in some vertebrate animals. However, there are no data showing the role of this system on nociception in the marsh terrapins. METHODOLOGY: In this study, the antinociceptive action of intrathecal administration...... of the α 2-adrenoreceptor agonist clonidine and α 2-adrenoreceptor antagonist yohimbine was evaluated in the African marsh terrapin using the formalin test. The interaction of clonidine and yohimbine was also evaluated. RESULTS: Intrathecal administration of clonidine (37.5 or 65 μg/kg) caused...... a significant reduction in the mean time spent in pain-related behavior. Yohimbine, at a dose of 25 μg/kg, significantly blocked the effect of clonidine (65 μg/kg). However, administration of yohimbine (40 or 53 μg/kg) caused a significant reduction in the mean time spent in pain-related behavior. Intrathecal...

  18. CT examination after intrathecal or intraventricular application of metrizamide in 110 patients for neurosurgery

    International Nuclear Information System (INIS)

    Krakow, D.

    1983-01-01

    The CT scans were done in 110 patients for examination of the liquor carrying cerebral brain compartments, especially the cisterns, after intrathecal application of the radiopaque medium metrizamide. The properties of the medium are explained in detail. (orig./MG) [de

  19. Efficacy of Polyvalent Human Immunoglobulins in an Animal Model of Neuromyelitis Optica Evoked by Intrathecal Anti-Aquaporin 4 Antibodies

    Directory of Open Access Journals (Sweden)

    Benedikt Grünewald

    2016-08-01

    Full Text Available Neuromyelitis Optica Spectrum Disorders (NMOSD are associated with autoantibodies (ABs targeting the astrocytic aquaporin-4 water channels (AQP4-ABs. These ABs have a direct pathogenic role by initiating a variety of immunological and inflammatory processes in the course of disease. In a recently-established animal model, chronic intrathecal passive-transfer of immunoglobulin G from NMOSD patients (NMO-IgG, or of recombinant human AQP4-ABs (rAB-AQP4, provided evidence for complementary and immune-cell independent effects of AQP4-ABs. Utilizing this animal model, we here tested the effects of systemically and intrathecally applied pooled human immunoglobulins (IVIg using a preventive and a therapeutic paradigm. In NMO-IgG animals, prophylactic application of systemic IVIg led to a reduced median disease score of 2.4 on a 0–10 scale, in comparison to 4.1 with sham treatment. Therapeutic IVIg, applied systemically after the 10th intrathecal NMO-IgG injection, significantly reduced the disease score by 0.8. Intrathecal IVIg application induced a beneficial effect in animals with NMO-IgG (median score IVIg 1.6 vs. sham 3.7 or with rAB-AQP4 (median score IVIg 2.0 vs. sham 3.7. We here provide evidence that treatment with IVIg ameliorates disease symptoms in this passive-transfer model, in analogy to former studies investigating passive-transfer animal models of other antibody-mediated disorders.

  20. 21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.

    Science.gov (United States)

    2010-04-01

    ... composite implant material. 878.3500 Section 878.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION... Prosthetic Devices § 878.3500 Polytetrafluoroethylene with carbon fibers composite implant material. (a) Identification. A polytetrafluoroethylene with carbon fibers composite implant material is a porous device...

  1. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  2. Intrathecal baclofen therapy in children with intractable spastic cerebral palsy: a cost-effectiveness analysis

    NARCIS (Netherlands)

    Hoving, M.A.; Evers, S.M.A.A.; Ament, A.J.H.A.; van Raak, E.P.M.; Becher, J.G.; Rotteveel, J.; Vles, J.S.H.

    2008-01-01

    In a Dutch national study, we recently established the effectiveness and safety of continuous intrathecal baclofen infusion (CITB) in children with intractable spastic cerebral palsy (CP). Because prospective studies on the cost-effectiveness of CITB in children with spastic CP are lacking, we

  3. Intrathecal baclofen therapy in children with intractable spastic cerebral palsy: a cost-effectiveness analysis.

    NARCIS (Netherlands)

    Hoving, M.A.; Evers, S.M.; Ament, A.J.; Raak, E.P. van; Vles, J.S.; Becher, J.G.; Vermeulen, R.; Brouwer, O.F.; Maathuis, C.G.B.; Catsman-Berrevoets, C.E.; Gerritsen, J.; Geerts, M.J.; Jongerius, P.H.; Nieuwenhuizen, O.F.; Rotteveel, J.J.; Speth, L.A.; Stroink, H.; Ziel, E.G. van der

    2008-01-01

    In a Dutch national study, we recently established the effectiveness and safety of continuous intrathecal baclofen infusion (CITB) in children with intractable spastic cerebral palsy (CP). Because prospective studies on the cost-effectiveness of CITB in children with spastic CP are lacking, we

  4. Enhanced drug delivery capabilities from stents coated with absorbable polymer and crystalline drug.

    Science.gov (United States)

    Carlyle, Wenda C; McClain, James B; Tzafriri, Abraham R; Bailey, Lynn; Zani, Brett G; Markham, Peter M; Stanley, James R L; Edelman, Elazer R

    2012-09-28

    Current drug eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug delivery. A novel, absorbable-coating sirolimus-eluting stent (AC-SES) was evaluated for its capacity to deliver drug more evenly within the intimal area rather than concentrating drug around the stent struts and for its ability to match coating erosion with drug release. The coating consisted of absorbable poly-lactide-co-glycolic acid (PLGA) and crystalline sirolimus deposited by a dry-powder electrostatic process. The AC-SES demonstrated enhanced drug stability under simulated use conditions and consistent drug delivery balanced with coating erosion in a porcine coronary implant model. The initial drug burst was eliminated and drug release was sustained after implantation. The coating was absorbed within 90 days. Following implantation into porcine coronary arteries the AC-SES coating is distributed in the surrounding intimal tissue over the course of several weeks. Computational modeling of drug delivery characteristics demonstrates how distributed coating optimizes the load of drug immediately around each stent strut and extends drug delivery between stent struts. The result was a highly efficient arterial uptake of drug with superior performance to a clinical bare metal stent (BMS). Neointimal thickness (0.17±0.07 mm vs. 0.28±0.11 mm) and area percent stenosis (22±9% vs. 35±12%) were significantly reduced (pstent implantation in an overlap configuration in porcine coronary arteries. Inflammation was significantly reduced in the AC-SES compared to the BMS at both 30 and 90 days after implantation. Biocompatible, rapidly absorbable stent coatings enable the matching of drug release with coating erosion and provide for the controlled migration of coating material into tissue to reduce vicissitudes in drug tissue levels, optimizing efficacy and reducing potential toxicity. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Chemokines CXCL10 and CCL2: differential involvement in intrathecal inflammation in multiple sclerosis

    DEFF Research Database (Denmark)

    Sørensen, T.L.; Sellebjerg, F; Jensen, C.V.

    2001-01-01

    leukocyte count, the CSF concentration of neopterin, matrix metalloproteinase (MMP)-9, and intrathecal IgG and IgM synthesis. The concentration of CCL2 increased between baseline for 3 weeks in both groups, more distinctly so in patients treated with methylprednisolone. CCL2 correlated negatively with MMP-9...... patients in relapse, whilst levels of CCL2 (MCP-1) were reduced. Here, we report a serial analysis of CSF CXCL10 and CCL2 concentrations in 22 patients with attacks of MS or acute optic neuritis (ON) treated with methylprednisolone, and 26 patients treated with placebo in two randomized controlled trials....... Chemokine concentrations were measured by enzyme linked immunosorbent assay (ELISA) in CSF obtained at baseline and after 3 weeks, and were compared with other measures of intrathecal inflammation. At baseline CSF concentrations of CCL2 were significantly lower in the patient group than in controls...

  6. Intrathecal dexmedetomidine as adjuvant for spinal anaesthesia for perianal ambulatory surgeries: A randomised double-blind controlled study

    Directory of Open Access Journals (Sweden)

    S S Nethra

    2015-01-01

    Full Text Available Background and Aim: The newer trend in regional anaesthesia for ambulatory anorectal surgeries advocate use of lower dose of local anaesthetic, providing segmental block with adjuvants such as opioids and α2 agonists to prolong analgesia. The current study investigated effects of addition of 5 μg of dexmedetomidine to 6 mg of hyperbaric bupivacaine on duration of analgesia, sensory and motor block characteristics for perianal ambulatory surgeries. Methods: This study is a prospective randomised controlled double blind study. Forty adult patients between 18 and 55 years of age were divided into 2 groups. Group D received intrathecal 0.5% hyperbaric bupivacaine 6 mg (1.2 ml with injection dexmedetomidine 5 μg in 0.5 ml of normal saline and Group N received intrathecal 0.5% hyperbaric bupivacaine 6 mg (1.2 ml with 0.5 ml of normal saline. The parameters assessed were time to regression of sensory blockade, motor blockade, ambulation, time to void, first administration of analgesic. Statistical analysis was done using appropriate tests. Results: Time for regression of sensory level and time for first administration of analgesic were prolonged in Group D (430.05 ± 89.13 min, 459.8 ± 100.9 min, respectively in comparison to Group N (301.10 ± 94.86 min, 321.85 ± 95.08 min, respectively. However, the duration of motor blockade, time to ambulation, and time to void were also significantly prolonged in Group D (323.05 ± 54.58 min, 329.55 ± 54.06 min, 422.30 ± 87.59 min than in Group N (220.10 ± 63.61 min, 221.60 ± 63.84 min, 328.45 ± 113.38 min. Conclusion: Intrathecal dexmedetomidine 5 μg added to intrathecal bupivacaine 6 mg as adjuvant may not be suitable for ambulatory perianal surgeries due to prolongation of motor blockade.

  7. 21 CFR 522.1662 - Oxytetracycline hydrochloride implantation or injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride implantation or injectable dosage forms. 522.1662 Section 522.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1662 Oxytetracycline hydrochloride implantation or injectable...

  8. Durable treatment response of relapsing CNS plasmacytoma using intrathecal chemotherapy, radiotherapy, and Daratumumab.

    Science.gov (United States)

    Elhassadi, Ezzat; Murphy, Maurice; Hacking, Dayle; Farrell, Michael

    2018-04-01

    CNS myelomatous involvement is a rare complication of multiple myeloma with dismal outcome. This disease's optimal treatment is unclear. Combined approach of systemic therapy, radiotherapy, and intrathecal injections chemotherapy should be considered and autologous stem cell transplant consolidation is offered to eligible patients. The role of Daratumumab in this disease deserves further evaluation.

  9. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  10. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  11. 21 CFR 872.3645 - Subperiosteal implant material.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3645 Subperiosteal implant material. (a) Identification. Subperiosteal implant material is a device composed of titanium or cobalt chrome molybdenum... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subperiosteal implant material. 872.3645 Section...

  12. Efficacy of magnesium sulphate and/or fentanyl as adjuvants to intrathecal low-dose bupivacaine in parturients undergoing elective caesarean section

    Directory of Open Access Journals (Sweden)

    Shelly Rana

    2017-01-01

    Full Text Available Background and Aim: Recent developments in the field of intrathecal adjuvants have led to accelerated functional recovery with adequate postoperative analgesia following caesarean section. Encouraging results have been obtained with the use of intrathecal magnesium with or without fentanyl in parturients. This study was conceived to evaluate the effects of adding magnesium sulphate and/or fentanyl to low-dose intrathecal bupivacaine in parturients undergoing caesarean section under subarachnoid block (SAB. Materials and Methods: Ninety, American Society of Anesthesiologists I or II, parturients for the elective caesarean section were enrolled in this prospective randomized, double-blind study. The parturients were randomly assigned to three groups. In Group M, parturients received 8.5 mg (1.7 mL hyperbaric bupivacaine 0.5% with 50 mg (0.1 mL magnesium sulphate and 0.4 mL normal saline. Group F received 8.5 mg hyperbaric bupivacaine 0.5% with 20 μg (0.4 mL fentanyl and 0.1 mL of normal saline and Group MF parturients received 8.5 mg hyperbaric bupivacaine 0.5% with 20 μg fentanyl added to 50 mg magnesium sulphate. Results: Parturients in the group MF were pain free for longest period (273.70 ± 49.30 min as compared to group M (252.67 ± 40.76 min and group F (239.80 ± 38.45 mins [gp MF vs F and, gp M vs F (P = 0.00]. The total doses of rescue analgesics were least in group MF (2.43 ± 0.56 and maximum in group F (3.30 ± 0.63, with comparable neonatal outcomes in three groups. Conclusion: Our data supports synergistic action of intrathecal magnesium sulphate to fentanyl, and it is concluded that on addition of intrathecal magnesium sulphate and fentanyl to low-dose bupivacaine as adjuvant in subarachnoid block, results in prolonged duration of postoperative analgesia with lesser pain scores and lesser dose of rescue analgesia with better haemodynamic stability.

  13. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  14. Implantable medical electronics prosthetics, drug delivery, and health monitoring

    CERN Document Server

    Khanna, Vinod Kumar

    2016-01-01

    This book is a comprehensive, interdisciplinary resource for the latest information on implantable medical devices, and is intended for graduate students studying electrical engineering, electronic instrumentation, and biomedical engineering. It is also appropriate for academic researchers, professional engineers, practicing doctors, and paramedical staff. Divided into two sections on Basic Concepts and Principles, and Applications, the first section provides an all-embracing perspective of the electronics background necessary for this work. The second section deals with pacing techniques used for the heart, brain, spinal cord, and the network of nerves that interlink the brain and spinal cord with the major organs, including ear and eye prostheses. The four main offshoots of implantable electronics, which this book discusses, are: The insertion of an implantable neural amplifier for accurate recording of neural signals for neuroengineering studies The use of implantable pulse generators for pacing the activi...

  15. Intrathecal Morphine for Laparoscopic Segmental Colonic Resection as Part of an Enhanced Recovery Protocol: A Randomized Controlled Trial.

    Science.gov (United States)

    Koning, Mark V; Teunissen, Aart Jan W; van der Harst, Erwin; Ruijgrok, Elisabeth J; Stolker, Robert Jan

    2018-02-01

    Management of postoperative pain after laparoscopic segmental colonic resections remains controversial. We compared 2 methods of analgesia within an Enhanced Recovery After Surgery (ERAS) program. The goal of the study was to investigate whether administration of intrathecal bupivacaine/morphine would lead to an enhanced recovery. A single-center, randomized, double-blind controlled trial was performed (NL43488.101.13). Patients scheduled for laparoscopic segmental intestinal resections were considered. Exclusion criteria were patients in whom contraindications to spinal anesthesia were present, conversion to open surgery, and gastric and rectal surgery. The intervention group received single-shot intrathecal bupivacaine/morphine (12.5 mg/300 μg), with an altered dose for older patients. The control group received a sham procedure and a bolus of piritramide (0.1 mg/kg). Both groups received standardized general anesthesia and a patient-controlled intravenous analgesia pump as postoperative analgesia. All patients were treated according to an ERAS protocol. A decrease in days to "fit for discharge" was the primary outcome. Fifty-six patients were enrolled. Intervention group patients were fit for discharge earlier (median of 3 vs 4 days, P = 0.044). Furthermore, there was a significant decrease in opioid use and lower pain scores on the first postoperative day in the intervention group. There were no differences in adverse events (except for more pruritus), time to mobilization, fluid administration, or patient satisfaction. This randomized controlled trial shows that intrathecal morphine is a more effective method of postoperative analgesia in laparoscopic surgery than intravenous opioids within an ERAS program. Recovery is faster and less painful with intrathecal morphine. Other studies have confirmed these results, although data on faster recovery are new and require confirmation in future trials. This study was registered at ClinicalTrials.gov, identifier NCT

  16. 21 CFR 872.3640 - Endosseous dental implant.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  17. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  18. Efficacy and Toxicity of Intrathecal Liposomal Cytarabine in First-line Therapy of Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Levinsen, Mette; Harila-Saari, Arja; Grell, Kathrine

    2016-01-01

    We investigated efficacy and toxicity of replacing conventional triple (cytarabine, methotrexate, and hydrocortisone) intrathecal therapy (TIT) with liposomal cytarabine during maintenance therapy among 40 acute lymphoblastic leukemia patients. Twenty-eight of 29 patients in the TIT arm received...

  19. 21 CFR 522.1696 - Penicillin G procaine implantation and injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin G procaine implantation and injectable dosage forms. 522.1696 Section 522.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... DOSAGE FORM NEW ANIMAL DRUGS § 522.1696 Penicillin G procaine implantation and injectable dosage forms. ...

  20. Detection of endotoxins in radiopharmaceutical preparations--I. Comparison of rabbit hyperthermia after intravenous or intrathecal administration of reference endotoxin preparations

    Energy Technology Data Exchange (ETDEWEB)

    Merlin, L; Bruneau, J; Cohen, Y; Michaud, T

    1986-01-01

    The rise of the rabbit internal temperature after endotoxin injection is related to the route of administration. A rise of 1.71 +/- 0.411/sup 0/C is obtained after i.v. injection of 1 ng/kg Escherichia coli 0111.B.4 endotoxin. An increase of 1.93 +/- 0.236/sup 0/C is obtained after suboccipital intrathecal injection of 0.1 ng/kg of the same endotoxin; with the intrathecal route, the hyperthermia is induced by E. coli endotoxin after a dose ten times lower than with i.v. injection as shown by statistical analysis.

  1. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  2. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  3. Osteoporotic rat models for evaluation of osseointegration of bone implants

    NARCIS (Netherlands)

    Alghamdi, H.S.A.; Beucken, J.J.J.P van den; Jansen, J.A.

    2014-01-01

    Osseointegration of dental and orthopedic bone implants is the important process that leads to mechanical fixation of implants and warrants implant functionality. In view of increasing numbers of osteoporotic patients, bone implant surface optimization strategies with instructive and drug-loading

  4. Drug loading of nanoporous TiO2 films

    International Nuclear Information System (INIS)

    Ayon, Arturo A; Cantu, Michael; Chava, Kalpana; Agrawal, C Mauli; Feldman, Marc D; Johnson, Dave; Patel, Devang; Marton, Denes; Shi, Emily

    2006-01-01

    The loading of therapeutic amounts of drug on a nanoporous TiO 2 surface is described. This novel drug-loading scheme on a biocompatible surface, when employed on medical implants, will benefit patients who require the deployment of drug-eluting implants. Anticoagulants, analgesics and antibiotics can be considered on the associated implants for drug delivery during the time of maximal pain or risk for patients undergoing orthopedic procedures. Therefore, this scheme will maximize the chances of patient recovery. (communication)

  5. Intrathecal application of /sup 198/Au colloid in acute leukemia and non-Hodgkin's lymphoma in chilhood. 2. Metaphylaxis of meningosis neoplastica

    Energy Technology Data Exchange (ETDEWEB)

    Metz, O; Unverricht, A; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic)

    1979-08-01

    7 children suffering from acute lymphatic leukemia (ALL) and non-Hodgkin's lymphoma, resp., were injected intrathecally with /sup 198/Au colloid for metaphylaxis. The children had been cured of 8 relapses of miningosis and received irregularly intrathecal injections of methotrexate for cerebral maintenance therapy. The median cerebral period of remission was 52 weeks. 1 child suffering from ALL had been free from meningosis relapses for 128 weeks. Continuous cytostatic therapy is necessary for methaphylaxis. However, despite of the good results presented, /sup 198/Au colloid can not be recommended for long-term therapy because radiation injuries are to be expected.

  6. Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural Technique with Intrathecal Plain Bupivacaine

    Directory of Open Access Journals (Sweden)

    Yu-Ying Tang

    2012-01-01

    Full Text Available Background. It was suggested that labor may influence the spread of intrathecal bupivacaine using combined spinal epidural (CSE technique. However, no previous studies investigated this proposition. We designed this study to investigate the spinal block characteristics of plain bupivacaine between nonlaboring and laboring parturients using CSE technique. Methods. Twenty-five nonlaboring (Group NL and twenty-five laboring parturients (Group L undergoing cesarean delivery were enrolled. Following identification of the epidural space at the L3-4 interspace, plain bupivacaine 10 mg was administered intrathecally using CSE technique. The level of sensory block, degree of motor block, and hemodynamic changes were assessed. Results. The baseline systolic blood pressure (SBP and the maximal decrease of SBP in Group L were significantly higher than those in Group NL (=0.002 and =0.03, resp.. The median sensory level tested by cold stimulation was T6 for Group NL and T5 for Group L (=0.46. The median sensory level tested by pinprick was T7 for both groups (=0.35. The degree of motor block was comparable between the two groups (=0.85. Conclusion. We did not detect significant differences in the sensory block levels between laboring and nonlaboring parturients using CSE technique with intrathecal plain bupivacaine.

  7. 21 CFR 882.5830 - Implanted diaphragmatic/phrenic nerve stimulator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted diaphragmatic/phrenic nerve stimulator... Implanted diaphragmatic/phrenic nerve stimulator. (a) Identification. An implanted diaphragmatic/phrenic nerve stimulator is a device that provides electrical stimulation of a patient's phrenic nerve to...

  8. Neuropathological findings after continuous intrathecal administration of S(+)-ketamine for the management of neuropathic cancer pain

    NARCIS (Netherlands)

    Vranken, J. H.; Troost, D.; Wegener, J. T.; Kruis, M. R.; van der Vegt, M. H.

    2005-01-01

    Questions have been raised about the potential neurotoxicity of the neuraxial use of ketamine although ketamine and its active enantiomer S(+)-ketamine have been used intrathecally and epidurally (caudally) for the management of perioperative pain and in a variety of chronic pain syndromes. Clinical

  9. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  10. Implantable and transdermal polymeric drug delivery technologies for the treatment of central nervous system disorders.

    Science.gov (United States)

    Govender, Thiresen; Choonara, Yahya E; Kumar, Pradeep; Bijukumar, Divya; du Toit, Lisa C; Modi, Girish; Naidoo, Dinesh; Pillay, Viness

    2017-06-01

    The complexity of the brain and the membranous blood-brain barrier (BBB) has proved to be a significant limitation to the systemic delivery of pharmaceuticals to the brain rendering them sub-therapeutic and ineffective in the treatment of neurological diseases. Apart from this, lack of innovation in product development to counteract the problem is also a major contributing factor to a poor therapeutic outcome. Various innovative strategies show potential in treating some of the neurological disorders; however, drug delivery remains the most popular. To attain therapeutic drug levels in the central nervous system, large, intolerable systemic doses are generally administered. The major factors responsible for the success maintenance therapy of neurological diseases included controlled and sustained release of neurotherapeutics, reduced frequency of administration, higher bioavailability, and patient compliances. Conventional oral or injectable formulations cannot satisfy all the requirements in many circumstances. This article reviews the therapeutic implantable polymeric and transdermal devices employed in an attempt to effectively achieve therapeutic quantities of drug across the BBB over a prolonged period, to improve patient disease prognosis.

  11. Long-term intrathecal baclofen: outcomes after more than 10 years of treatment.

    Science.gov (United States)

    Mathur, Sunjay N; Chu, Samuel K; McCormick, Zack; Chang Chien, George C; Marciniak, Christina M

    2014-06-01

    To report outcomes of intrathecal baclofen (ITB) therapy for spasticity management in a cohort of patients who had received this treatment for at least 10 years. A cross-sectional survey and retrospective chart review. An academic rehabilitation outpatient clinic. Adult patients with spasticity treated with ITB for at least 10 years. Surveys included the Brief Pain Inventory, Penn Spasm Frequency Scale, Epworth Sleepiness Scale, Fatigue Severity Scale, Diener Satisfaction with Life, Life Satisfaction Questionnaire, and Intrathecal Baclofen Survey. Twenty-four subjects completed the surveys. The subjects had been treated with ITB from 10.0-28.4 years, with a mean (standard deviation) of 14.7 ± 4.2 years. The mean (standard deviation) dose of ITB was 627.9 ± 306.7 μg/d, with only 6 subjects averaging daily dose changes of more than 10% compared with 3 years earlier. The mean (standard deviation) scores on outcomes surveys were the following: 2.6 ± 2.3 for pain severity on the Brief Pain Inventory, 1.4 ± 0.7 for spasm severity on the Penn Spasm Frequency Scale, 7.9 ± 5.4 on the Epworth Sleepiness Scale, 4.1 ± 1.6 on the Fatigue Severity Scale, 19.4 ± 8.1 on the Diener Satisfaction with Life, 3.9 ± 0.9 on the Life Satisfaction Questionnaire, and 8.8 ± 1.9 for overall satisfaction with ITB on the Intrathecal Baclofen Survey. On the Brief Pain Inventory, the mean scores for pain severity and interference of pain with life showed moderate inverse correlations with ITB dose (r = -0.386, P = .115; and r = -0.447, P = .062, respectively). On the Life Satisfaction Questionnaire, the mean scores for life satisfaction showed statistically significant positive correlation with ITB dose (r = 0.549, P = .021). The subjects reported low levels of pain, moderate levels of life satisfaction, normal levels of sleepiness, low-to-moderate levels of fatigue, infrequent spasms at mild-to-moderate severity, and high levels of satisfaction. The efficacy and favorable adverse

  12. 21 CFR 882.5840 - Implanted intracerebral/subcortical stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ... pain relief. 882.5840 Section 882.5840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 882.5840 Implanted intracerebral/subcortical stimulator for pain relief. (a) Identification. An implanted intracerebral/subcortical stimulator for pain relief is a device that applies electrical current...

  13. Dosimetry in intrathecal radiogold therapy. 5. Principles of gonad dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Hliscs, R; Doege, H [Medizinische Akademie, Dresden (German Democratic Republic). Nuklearmedizinische Klinik

    1980-10-01

    Basing on MIRD recommendations the absorbed dose per unit of accumulated activity in the ovaries and testes is calculated when radioactivity is accumulated in the spinal and cerebral liquor space as well as in the liver following instillation of /sup 198/Au colloid for intrathecal therapy of acute leukemia in childhood. The calculations were made for the IAEA standard man as well as for a 100 cm tall child. Besides that the maximum value of ovarian exposure for the child was determined which arises when the ovaries are close to the spinal column.

  14. Intrathecally enhanced spinal CT in the early diagnosis of cerebrospinal fluid-borne metastasis in pediatric patients with primary brain tumors

    International Nuclear Information System (INIS)

    Wang, H.; Rosenbaum, A.E.; Ahn, H.S.; Zinreich, S.J.; Diffley, D.M.; Killmond, T.A.; Strauss, L.C.

    1987-01-01

    Early diagnosis and treatment of asymptomatic intraspinal cerebrospinal fluid-borne metastases can obviate serious sequelae in pediatric patients with known intracranial tumors. MR imaging is a superior imaging modality; however, in very young patients who need general anesthesia for immobilization and also for evaluation of small subarachnoid seedings, the authors found CT to be a valuable alternative. Twelve patients ranging in age from 3 months to 13 years underwent CT screening of the entire spine after intrathecal enhancement with 3-5 ml of metrizamide (100 mg iodine per milliliter) via a lumbar puncture. Intrathecal spinal metastases were found in 67% of the studied patients and even in a patient whose MR imaging examination failed to disclose the lesion

  15. Spinal cord distribution of sup 3 H-morphine after intrathecal administration: Relationship to analgesia

    Energy Technology Data Exchange (ETDEWEB)

    Nishio, Y.; Sinatra, R.S.; Kitahata, L.M.; Collins, J.G. (Yale Univ. School of Medicine, CT (USA))

    1989-09-01

    The distribution of intrathecally administered {sup 3}H-morphine was examined by light microscopic autoradiography in rat spinal cord and temporal changes in silver grain localization were compared with results obtained from simultaneous measurements of analgesia. After tissue processing, radio-activity was found to have penetrated in superficial as well as in deeper layers (Rexed lamina V, VII, and X) of rat spinal cord within minutes after application. Silver grain density reached maximal values at 30 min in every region of cord studied. Radioactivity decreased rapidly between 30 min and 2 hr and then more slowly over the next 24 hr. In rats tested for responses to a thermal stimulus (tail flick test), intrathecal administration of morphine (5 and 15 micrograms) resulted in significant dose dependent analgesia that peaked at 30 min and lasted up to 5 hr (P less than 0.5). There was a close relationship between analgesia and spinal cord silver grain density during the first 4 hr of the study. It is postulated that the onset of spinal morphine analgesia depends on appearance of molecules at sites of action followed by the activation of anti-nociceptive mechanisms.

  16. Intrathecal antitetanus serum (horse) with steroid in the treatment of neonatal tetanus.

    OpenAIRE

    Singh, A K; Bansal, A; Goel, S P; Agarwal, V K

    1980-01-01

    107 patients with neonatal tetanus were studied and the value of intrathecal antitetanus serum with steroid was noted. The mortality rate in a control group (68%) was significantly higher than that of the test group (37%). Furthermore, a delay in antitetanus serum administration was found to have a strong positive linear correlation with the mortality rate. In fact, the mortality rate for neonates who were given antitetanus serum 24 hours after the onset of convulsions was found to be as high...

  17. Clinically Isolated Syndrome According to McDonald 2010: Intrathecal IgG Synthesis Still Predictive for Conversion to Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Philipp Schwenkenbecher

    2017-09-01

    Full Text Available While the revised McDonald criteria of 2010 allow for the diagnosis of multiple sclerosis (MS in an earlier stage, there is still a need to identify the risk factors for conversion to MS in patients with clinically isolated syndrome (CIS. Since the latest McDonald criteria were established, the prognostic role of cerebrospinal fluid (CSF and visual evoked potentials (VEP in CIS patients is still poorly defined. We conducted a monocentric investigation including patients with CIS in the time from 2010 to 2015. Follow-ups of 120 patients revealed that 42% converted to MS. CIS patients with positive oligoclonal bands (OCB were more than twice as likely to convert to MS as OCB negative patients (hazard ratio = 2.6. The probability to develop MS was even higher when a quantitative intrathecal IgG synthesis was detected (hazard ratio = 3.8. In patients with OCB, VEP did not add further information concerning the conversion rate to MS. In patients with optic neuritis and negative OCB, a significantly higher rate converted to MS when VEP were delayed. In conclusion, the detection of an intrathecal IgG synthesis increases the conversion probability to MS. Pathological VEP can help to predict the conversion rate to MS in patients with optic neuritis without an intrathecal IgG synthesis.

  18. Intrathecal dihydroergotamine inhibits capsaicin-induced vasodilatation in the canine external carotid circulation via GR127935- and rauwolscine-sensitive receptors.

    Science.gov (United States)

    Marichal-Cancino, Bruno A; González-Hernández, Abimael; Manrique-Maldonado, Guadalupe; Ruiz-Salinas, Inna I; Altamirano-Espinoza, Alain H; MaassenVanDenBrink, Antoinette; Villalón, Carlos M

    2012-10-05

    It has been suggested that during a migraine attack trigeminal nerves release calcitonin gene-related peptide (CGRP), producing central nociception and vasodilatation of cranial arteries, including the extracranial branches of the external carotid artery. Since trigeminal inhibition may prevent this vasodilatation, the present study has investigated the effects of intrathecal dihydroergotamine on the external carotid vasodilatation to capsaicin, α-CGRP and acetylcholine. Anaesthetized vagosympathectomized dogs were prepared to measure blood pressure, heart rate and external carotid conductance. A catheter was inserted into the right common carotid artery for the continuous infusion of phenylephrine (to restore the carotid vascular tone), whereas the corresponding thyroid artery was cannulated for one-min intracarotid infusions of capsaicin, α-CGRP and acetylcholine (which dose-dependently increased the external carotid conductance). Another cannula was inserted intrathecally (C(1)-C(3)) for the administration of dihydroergotamine, the α(2)-adrenoceptor antagonist rauwolscine or the serotonin 5-HT(1B/1D) receptor antagonist GR127935 (N-[4-methoxy-3-(4-methyl-1-piperazinyl) phenyl]-2'-methyl-4'-(5-methyl-1,2,4-oxadiazol-3-yl)[1,1-biphenyl]-4-carboxamide hydrochloride monohydrate). Intrathecal dihydroergotamine (10, 31 and 100μg) inhibited the vasodilatation to capsaicin, but not that to α-CGRP or acetylcholine. This inhibition was: (i) unaffected by 10μg GR127935 or 100μg rauwolscine, but abolished by 31μg GR127935 or 310μg rauwolscine at 10μg dihydroergotamine; and (ii) abolished by the combination 10μg GR127935+100μg rauwolscine at 100μg dihydroergotamine. Thus, intrathecal (C(1)-C(3)) dihydroergotamine seems to inhibit the external carotid vasodilatation to capsaicin by spinal activation of serotonin 5-HT(1B/1D) (probably 5-HT(1B)) receptors and α(2) (probably α(2A/2C))-adrenoceptors. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. 'Breath figure' PLGA films as implant coatings for controlled drug release

    Science.gov (United States)

    Ponnusamy, Thiruselvam

    The breath figure method is a versatile and facile approach of generating ordered micro and nanoporous structures in polymeric materials. When a polymer solution (dissolved in a high vapor pressure organic solvent) is evaporated out in the presence of a moist air stream, the evaporative cooling effect causes the condensation and nucleation of water droplets onto the polymer solution surface. This leads to the formation of an imprinted porous structure upon removal of the residual solvent and water. The facile removal of the water droplet template leaving its structural imprint is a specifically appealing aspect of the breath figure film technology. The first part of the dissertation work involves the fabrication of drug loaded breath figure thin films and its utilization as a controlled drug release carrier and biomaterial scaffold. In a single fabrication step, single layer/multilayer porous thin films were designed and developed by combining the breath figure process and a modified spin or dip coating technique. Using biodegradable polymers such as poly (lactic-co-glycolic acid) (PLGA) and poly (ethylene glycol) (PEG), drug loaded films were fabricated onto FDA approved medical devices (the Glaucoma drainage device and the Surgical hernia mesh). The porosity of the films is in the range of 2-4 microm as characterized by scanning electron microscope. The drug coated medical implants were characterized for their surface and bulk morphology, the degradation rate of the film, drug release rate and cell cytotoxicity. The results suggest that the use of breath figure morphologies in biodegradable polymer films adds an additional level of control to drug release. In comparison to non-porous films, the breath figure films showed an increased degradation and enhanced drug release. Furthermore, the porous nature of the film was investigated as a biomaterial scaffold to construct three dimensional in vitro tissue model systems. The breath figure film with interconnected

  20. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  1. 21 CFR 1308.26 - Excluded veterinary anabolic steroid implant products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Excluded veterinary anabolic steroid implant... SCHEDULES OF CONTROLLED SUBSTANCES Excluded Veterinary Anabolic Steroid Implant Products § 1308.26 Excluded veterinary anabolic steroid implant products. (a) Products containing an anabolic steroid, that are expressly...

  2. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  3. Leukoencephalopathy and cortical leminar necrosis associated with intrathecal methotrexate and cranial irridiation

    International Nuclear Information System (INIS)

    Iqbal, Yasir; Al-Sudairy, Reem; Abdullah, Mohammad F.

    2003-01-01

    With the advent of chemotherapy, mortality rates in children with acute lymphoblastic leukemia have decreased . Though prophylactic treatment of central nervous system (CNS) to prevent leukemic infiltration has reduced the incidence of CNS relapse and improved the survival in pediatric acute lymphoblastic leukemia. We studied a unique case of neurotoxicity associated with prophylactic cranial irradiation and intrathecal MTX. This is the first reported case of pure MTX-related CLN.Perhaps the combination of MTX along with cranial irradiation, can result in increased neurotoxic effects. (author)

  4. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation

    Directory of Open Access Journals (Sweden)

    S. Lumetti

    2016-01-01

    Full Text Available Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD and oral parafunction (OP rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  5. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.

    Science.gov (United States)

    Lumetti, S; Ghiacci, G; Macaluso, G M; Amore, M; Galli, C; Calciolari, E; Manfredi, E

    2016-01-01

    Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  6. Safely re-integrating silicone breast implants into the plastic surgery practice.

    Science.gov (United States)

    Gladfelter, Joanne

    2006-01-01

    In the early 1990s, it was reported that silicone breast implants were possibly responsible for serious damage to women's health. In January 1992, the Food and Drug Administration issued a voluntary breast implant moratorium and, in April, issued a ban on the use of silicone gel-filled implants for cosmetic breast augmentation. Since that time, silicone gel-filled breast implants have been available to women only for select cases: women seeking breast reconstruction or revision of an existing breast implant, women who have had breast cancer surgery, a severe injury to the breast, a birth defect that affects the breast, or a medical condition causing a severe breast deformity. Since the ban on the use of silicone gel-filled breast implants for cosmetic breast augmentation, numerous scientific studies have been conducted. To ensure patient safety, the American Board of Plastic Surgery believes that these scientific studies and the Food and Drug Administration's scrutiny of silicone gel-filled breast implants have been appropriate and necessary.

  7. Progression of scoliosis in patients with spastic quadriplegia after the insertion of an intrathecal baclofen pump.

    Science.gov (United States)

    Ginsburg, Glen M; Lauder, Anthony J

    2007-11-15

    Medical and radiographic review of 19 consecutive patients with spastic quadriplegia before and after intrathecal baclofen pump insertion with special attention paid to progression of scoliosis. Many orthopedic surgeons who treat spastic quadriplegic patients have noticed a trend of marked scoliosis progression after the administration of intrathecal baclofen (ITB) via subcutaneous pump and catheter. The purpose of this study is to quantify scoliosis progression in this patient population before and after baclofen administration and compare this to published natural history data. The authors had noted rapid progression of scoliosis in spastic quadriplegic patients after intrathecal baclofen pump insertion. This had been noted at other centers, but no significant statistical analysis had been done comparing prepump to postpump scoliosis progression in these patients. To document the magnitude and rate of scoliosis progressions after the placement of an ITB pump, the charts and radiographs of 19 consecutive nonambulatory patients with spastic quadriplegia and an ITB pump were reviewed. To document the rate of scoliosis progression, each patient had at least 2 pre and 2 postpump insertion spinal radiographs made. All radiographs were made with the patients in the supine position without orthoses. A board-certified orthopedic surgeon reviewed these radiographs. Skeletal maturity was assessed using Risser grading. Catheter tip location and rate of baclofen administration were recorded. For 19 patients with complete radiographic data, average Cobb angles were 10.2 degrees before pump insertion and 25 degrees at an average of 20.9 months after pump insertion (P quadriplegia and ITB pump. The authors are now performing spinal fusions for curves that exceed 40 degrees to 50 degrees in the presence of an ITB pump as recommended by previous reviews of scoliosis and accompanying quadriplegia.

  8. Failure of Urological Implants in Spinal Cord Injury Patients due to Infection, Malfunction, and Implants Becoming Obsolete due to Medical Progress and Age-Related Changes in Human Body Making Implant Futile: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2013-01-01

    Full Text Available Any new clinical data, whether positive or negative, generated about a medical device should be published because health professionals should know which devices do not work, as well as those which do. We report three spinal cord injury patients in whom urological implants failed to work. In the first, paraplegic, patient, a sacral anterior root stimulator failed to produce erection, and a drug delivery system for intracavernosal administration of vasoactive drugs was therefore implanted; however, this implant never functioned (and, furthermore, such penile drug delivery systems to produce erection had effectively become obsolete following the advent of phosphodiesterase type 5 inhibitors. Subsequently, the sacral anterior root stimulator developed a malfunction and the patient therefore learned to perform self-catheterisation. In the second patient, also paraplegic, an artificial urinary sphincter was implanted but the patient developed a postoperative sacral pressure sore. Eight months later, a suprapubic cystostomy was performed as urethral catheterisation was very difficult. The pressure sore had not healed completely even after five years. In the third case, a sacral anterior root stimulator was implanted in a tetraplegic patient in whom, after five years, a penile sheath could not be fitted because of penile retraction. This patient was therefore established on urethral catheter drainage. Later, infection with Staphylococcus aureus around the receiver block necessitated its removal. In conclusion, spinal cord injury patients are at risk of developing pressure sores, wound infections, malfunction of implants, and the inability to use implants because of age-related changes, as well as running the risk of their implants becoming obsolete due to advances in medicine. Some surgical procedures such as dorsal rhizotomy are irreversible. Alternative treatments such as intermittent catheterisations may be less damaging than bladder stimulator in

  9. Effect of Single Shot Intrathecal Sufentanil on Delivery Time and Analgesia in Nuliparae

    Directory of Open Access Journals (Sweden)

    E. Khoshraftar

    2008-04-01

    Full Text Available Introduction & Objective : The objective of this study was to determine the evaluation of intrathecal sufentanil for labor analgesia with respect to duration of labor stages and relief of pain during labor.Materials & Methods : In a clinical trial 60 subjects with ASA class I were selected and randomly divided in two equal groups. 30 subjects had received sufentanil 10 gr in 1 ml of saline during active phase of first stage of labor. The other group as controls, did not receive anything for analgesia. Parturient visual analog scale (VAS , HR, RR, BP, sensory and motor block, FHR and complications such as nausea, vomiting, pruritus and duration of stage I been monitored recorded and compared among those two groups.Results : Comparison of results in two groups have showed that sufentanil does not prolong the duration of labor in stage 1 and 2. We observed lack of hypotension and respiratory depression in sufentanil group FHR changes that had been associated with adverse neonatal out come had not occurred. The apgar scores in two groups were identical. There was itching in majority of parturient who had received sufentanil (83.3%. The pruritus were defined as mild and moderate. Conclusion : Intrathecal sufentanil provide a good analgesia in stage I labor and does not prolong the duration of labor with minimum adverse effects on parturient and fetus.

  10. Microchips and controlled-release drug reservoirs.

    Science.gov (United States)

    Staples, Mark

    2010-01-01

    This review summarizes and updates the development of implantable microchip-containing devices that control dosing from drug reservoirs integrated with the devices. As the expense and risk of new drug development continues to increase, technologies that make the best use of existing therapeutics may add significant value. Trends of future medical care that may require advanced drug delivery systems include individualized therapy and the capability to automate drug delivery. Implantable drug delivery devices that promise to address these anticipated needs have been constructed in a variety of ways using micro- and nanoelectromechanical systems (MEMS or NEMS)-based technology. These devices expand treatment options for addressing unmet medical needs related to dosing. Within the last few years, advances in several technologies (MEMS or NEMS fabrication, materials science, polymer chemistry, and data management) have converged to enable the construction of miniaturized implantable devices for controlled delivery of therapeutic agents from one or more reservoirs. Suboptimal performance of conventional dosing methods in terms of safety, efficacy, pain, or convenience can be improved with advanced delivery devices. Microchip-based implantable drug delivery devices allow localized delivery by direct placement of the device at the treatment site, delivery on demand (emergency administration, pulsatile, or adjustable continuous dosing), programmable dosing cycles, automated delivery of multiple drugs, and dosing in response to physiological and diagnostic feedback. In addition, innovative drug-medical device combinations may protect labile active ingredients within hermetically sealed reservoirs. Copyright (c) 2010 John Wiley & Sons, Inc.

  11. Central neuraxial opioid analgesia after caesarean section: comparison of epidural diamorphine and intrathecal morphine.

    Science.gov (United States)

    Caranza, R; Jeyapalan, I; Buggy, D J

    1999-04-01

    In a prospective, randomized, double-blind study in 55 women undergoing elective caesarean section under spinal anaesthesia, we compared epidural diamorphine 3 mg (2 distinct boluses, group ED) with single-dose intrathecal morphine 0.2 mg (group SM), in terms of analgesic efficacy, patient satisfaction and side-effects at 2, 3, 4, 8, 12, 16, 24 and 28 h postoperatively. There were no significant differences between groups in pain (assessed by 100 mm visual analogue scale), incidence of pruritus, sedation or respiratory depression measured by continuous pulse oximetry. However, time to first request for supplementary oral analgesia was longer in SM than in ED (mean +/- SD: 22.3+/-12.0 h vs. 13.8+/-6.5 h, P=0.04). The incidence of nausea or vomiting was significantly higher in SM than ED (73% vs. 41%, P=0.01). In ED, the mean +/- SD time to requirement of the second bolus was 6.7+/-3.2 h. There was a high level of satisfaction in both groups. We conclude that two boluses of epidural diamorphine 3 mg and single-dose intrathecal morphine 0.2 mg provide satisfactory analgesia after caesarean section, but spinal morphine was associated with both delayed requirement for supplementary analgesia and a higher incidence of nausea and vomiting.

  12. 21 CFR 874.3695 - Mandibular implant facial prosthesis.

    Science.gov (United States)

    2010-04-01

    ... made of materials such as stainless steel, tantalum, titanium, cobalt-chromium based alloy... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mandibular implant facial prosthesis. 874.3695... (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3695 Mandibular implant...

  13. Effect of S-methyl-l-thiocitrulline dihydrochloride on rat micturition reflex

    Directory of Open Access Journals (Sweden)

    Jeová Nina Rocha

    Full Text Available ABSTRACT Objective: To evaluate the effect of neuronal nitric oxide synthase on the striated urethral sphincter and the urinary bladder. Materials and Methods: A coaxial catheter was implanted in the proximal urethra and another one in the bladder of female rats, which were anesthetized with subcutaneous injection of urethane. The urethral pressure with saline continuous infusion and bladder isovolumetric pressure were simultaneously recorded. Two groups of rats were formed. In group I, an intrathecal catheter was implanted on the day of the experiment at the L6-S1 level of the spinal cord; in group II, an intracerebroventricular cannula was placed 5-6 days before the experiment. Results: It was verified that the group treated with S-methyl-L-thio-citrulline, via intrathecal pathway, showed complete or partial inhibition of the urethral sphincter relaxation and total inhibition of the micturition reflexes. The urethral sphincter and the detrusor functions were recovered after L-Arginine administration. When S-methyl-L-thio-citrulline was administered via intracerebroventricular injection, there was a significant increase of urethral sphincter tonus while preserving the sphincter relaxation and the detrusor contractions, at similar levels as before the use of the drugs. Nevertheless there was normalization of the urethral tonus when L-Arginine was applied. Conclusions: The results indicate that, in female rats anaesthetized with urethane, the nNOS inhibitor administrated through the intrathecal route inhibits urethral sphincter relaxation, while intracerebroventricular injection increases the sphincter tonus, without changing bladder function. These changes were reverted by L-Arginine administration. These findings suggest that the urethral sphincter and detrusor muscle function is modulated by nitric oxide.

  14. Penile implants among prisoners-a cause for concern?

    Directory of Open Access Journals (Sweden)

    Lorraine Yap

    Full Text Available BACKGROUND: We report the prevalence of penile implants among prisoners and determine the independent predictors for having penile implants. Questions on penile implants were included in the Sexual Health and Attitudes of Australian Prisoners (SHAAP survey following concerns raised by prison health staff that increasing numbers of prisoners reported having penile implants while in prison. METHODS: Computer-Assisted Telephone Interviewing (CATI of a random sample of prisoners was carried out in 41 prisons in New South Wales and Queensland (Australia. Men were asked, "Have you ever inserted or implanted an object under the skin of your penis?" If they responded Yes: "Have you ever done so while you were in prison?" Univariate logistic regression and logistic regression were used to determine the factors associated with penile implants. RESULTS: A total of 2,018 male prisoners were surveyed, aged between 18 and 65 years, and 118 (5.8% reported that they had inserted or implanted an object under the skin of their penis. Of these men, 87 (73% had this done while they were in prison. In the multivariate analysis, a younger age, birth in an Asian country, and prior incarceration were all significantly associated with penile implants (p<0.001. Men with penile implants were also more likely to report being paid for sex (p<0.001, to have had body piercings (p<0.001 or tattoos in prison (p<0.001, and to have taken non-prescription drugs while in prison (p<0.05. CONCLUSIONS: Penile implants appear to be fairly common among prisoners and are associated with risky sexual and drug use practices. As most of these penile implants are inserted in prison, these men are at risk of blood borne viruses and wound infection. Harm reduction and infection control strategies need to be developed to address this potential risk.

  15. Successful drug-eluting stent implantation in a male patient with dextrocardia: a case report

    Directory of Open Access Journals (Sweden)

    Long Wenjie

    2017-12-01

    Full Text Available Situs inversus with dextrocardia is a rare condition, with complete transposition of all the body organs, including the heart. Percutaneous coronary intervention (PCI in these patients is technically difficult because of the mirror image of organs. Here, we describe a 56-year-old man with coronary heart disease with known situs inversus with dextrocardia and coronary percutaneous intervention was performed for stenosis in the right coronary artery. A drug eluting stent was implanted at this site successfully. This case suggested that the interventional management of such patients follows the same general rules as for non-dextrocardia patients, but the manipulation of the catheter and projection position choices need to be taken into consideration to obtain optimal benefits for the patient.

  16. 21 CFR 882.5870 - Implanted peripheral nerve stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ....5870 Implanted peripheral nerve stimulator for pain relief. (a) Identification. An implanted peripheral nerve stimulator for pain relief is a device that is used to stimulate electrically a peripheral nerve... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted peripheral nerve stimulator for pain...

  17. Human interleukin-10 delivered intrathecally by self-complementary adeno-associated virus 8 induces xenogeneic transgene immunity without clinical neurotoxicity in swine.

    Science.gov (United States)

    Unger, Mark D; Pleticha, Josef; Heilmann, Lukas F; Newman, Laura K; Maus, Timothy P; Beutler, Andreas S

    2018-05-25

    Intrathecal interleukin-10 delivered by plasmid or viral gene vectors has been proposed for clinical testing because it is effective for chronic pain in rodents, a potential therapeutic for various human diseases, and was found to be non-toxic in dogs, when the human interleukin-10 ortholog was tested. However, recent studies in swine testing porcine interleukin-10 demonstrated fatal neurotoxicity. To deliver vector-encoded human interleukin-10 in swine, measure expression of the transgene in cerebrospinal fluid, and monitor animals for signs of neurotoxicity. Human interleukin-10 levels peaked 2 weeks after vector administration followed by a rapid decline that occurred concomitant with the emergence of anti-human interleukin-10 antibodies in the cerebrospinal fluid and serum. Animals remained neurologically healthy throughout the study period. This study suggests that swine are not idiosyncratically sensitive to intrathecal interleukin-10 because, recapitulating previous reports in dogs, they suffered no clinical neurotoxicity from the human ortholog. These results strongly infer that toxicity of intrathecal interleukin-10 in large animal models was previously overlooked because of a species mismatch between transgene and host. The present study further suggests that swine were protected from interleukin-10 by a humoral immune response against the xenogeneic cytokine. Future safety studies of interleukin-10 or related therapeutics may require syngeneic large animal models. This article is protected by copyright. All rights reserved.

  18. CNS penetration of intrathecal-lumbar idursulfase in the monkey, dog and mouse: implications for neurological outcomes of lysosomal storage disorder.

    Directory of Open Access Journals (Sweden)

    Pericles Calias

    Full Text Available A major challenge for the treatment of many central nervous system (CNS disorders is the lack of convenient and effective methods for delivering biological agents to the brain. Mucopolysaccharidosis II (Hunter syndrome is a rare inherited lysosomal storage disorder resulting from a deficiency of iduronate-2-sulfatase (I2S. I2S is a large, highly glycosylated enzyme. Intravenous administration is not likely to be an effective therapy for disease-related neurological outcomes that require enzyme access to the brain cells, in particular neurons and oligodendrocytes. We demonstrate that intracerebroventricular and lumbar intrathecal administration of recombinant I2S in dogs and nonhuman primates resulted in widespread enzyme distribution in the brain parenchyma, including remarkable deposition in the lysosomes of both neurons and oligodendrocytes. Lumbar intrathecal administration also resulted in enzyme delivery to the spinal cord, whereas little enzyme was detected there after intraventricular administration. Mucopolysaccharidosis II model is available in mice. Lumbar administration of recombinant I2S to enzyme deficient animals reduced the storage of glycosaminoglycans in both superficial and deep brain tissues, with concurrent morphological improvements. The observed patterns of enzyme transport from cerebrospinal fluid to the CNS tissues and the resultant biological activity (a warrant further investigation of intrathecal delivery of I2S via lumbar catheter as an experimental treatment for the neurological symptoms of Hunter syndrome and (b may have broader implications for CNS treatment with biopharmaceuticals.

  19. Antibiotic use during the intracoelomic implantation of electronic tags into fish

    Science.gov (United States)

    Mulcahy, D.M.

    2011-01-01

    The use of antibiotics, in particular, the use of a single dose of antibiotics during electronic tag implantation is of unproven value, and carries with it the potential for the development of antibiotic resistance in bacteria and the alteration of the immune response of the fish. Antibiotic use during electronic tag implantation must conform to relevant drug laws and regulations in the country where work is being done, including the requirements for withdrawal times before human consumption is a possibility. Currently, the choice of antibiotics (most often tetracycline or oxytetracycline) and the use of a single dose of the drug are decisions made without knowledge of the basic need for antibiotic usage and of the bacteria involved in infections that occur following electronic tag implantation. Correct perioperative use of an antibiotic is to apply the drug to the animal before surgery begins, to assure serum and tissue levels of the drug are adequate before the incision is made. However, the most common perioperative application of antibiotics during implantation of an electronic tag is to delay the administration of the drug, injecting it into the coelom after the electronic tag is inserted, just prior to closure of the incision. There is little empirical evidence that the present application of antibiotics in fish being implanted with electronic tags is of value. Improvements should first be made to surgical techniques, especially the use of aseptic techniques and sterilized instruments and electronic tags, before resorting to antibiotics. ?? 2010 Springer Science+Business Media B.V.(outside the USA).

  20. Prognostic Value of Plasma Pentraxin-3 Levels in Patients with Stable Coronary Artery Disease after Drug-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Liu Haibo

    2014-01-01

    Full Text Available Pentraxin-3 (PTX3 is an inflammatory marker thought to be more specific to cardiovascular inflammation than C-reactive protein (CRP. Our aim was to assess the prognostic value of PTX3 in patients with stable coronary artery disease (CAD after drug eluting stent (DES implantation. Plasma PTX3 levels were measured before percutaneous coronary intervention (PCI and at 24 h post-PCI in 596 consecutive patients with stable CAD. Patients were followed up for a median of 3 years (range 1–5 for major adverse cardiovascular events (MACEs. We found that the post-PCI plasma PTX3 levels were significantly higher at 24 h after PCI than pre-PCI, patients with MACEs had higher post-PCI PTX3 levels compared with MACEs-free patients, patients with higher post-PCI PTX3 levels (median > 4.384 ng/mL had a higher risk for MACEs than those with PTX3 < 4.384 ng/mL, and post-PCI PTX3, cTnI, multiple stents, and age but not high-sensitivity CRP (hsCRP were independently associated with the prevalence of MACEs after DES implantation. The present study shows that post-PCI PTX3 may be a more reliable inflammatory predictor of long-term MACEs in patients with stable CAD undergoing DES implantation than CRP. Measurement of post-PCI PTX3 levels could provide a rationale for risk stratification of patients with stable CAD after DES implantation.

  1. To evaluate the efficacy of intrathecal magnesium sulphate for hysterectomy under subarachnoid block with bupivacaine and fentanyl: A prospective randomized double blind clinical trial

    Directory of Open Access Journals (Sweden)

    Mridu Paban Nath

    2012-01-01

    Full Text Available Background: Intrathecal magnesium has been found to prolong the duration of analgesia in various surgical procedures like lower limb surgeries and as adjuncts to general anesthesia for pain management. The present study was designed to examine whether addition of intrathecal magnesium sulfate would enhance the analgesic efficacy of intrathecal bupivacaine and fentanyl in patients undergoing total abdominal hysterectomy. Methods: After taking informed consent, 60 patients were randomised into two groups with 30 patients. Group "S" received 2.5 mL (12.5 mg of hyperbaric bupivacaine + 0.5 mL (25 mcg of fentanyl + 0.5 mL of normal saline and Group "M" received 2.5 mL (12.5 mg of hyperbaric bupivacaine + 0.5 mL (25 mcg of fentanyl + 0.5 mL (100 mg of magnesium sulfate. Onset of sensory, motor block and duration of analgesia was noted. Results: Demographic profile and duration of surgery were comparable (P>0.5. Time of onset of sensory and motor blockade was delayed in Group M compared with Group S, and this was statistically significant. A statistically significant longer duration of analgesia was observed in Group M compared with the control Group S. However, the recovery of motor blockade was found to be statistically insignificant in both the groups. The hemodynamic parameters were comparable in the perioperative period (P>0.05. The incidence of side-effects in both the groups were also comparable (P>0.05. Conclusion: The addition of 100 mg intrathecal magnesium led to prolonged duration of analgesia significantly without increasing the incidence of side-effects. Also, there was a significant delay in the onset of both sensory and motor blockade.

  2. 21 CFR 882.5880 - Implanted spinal cord stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted spinal cord stimulator for pain relief... Implanted spinal cord stimulator for pain relief. (a) Identification. An implanted spinal cord stimulator for pain relief is a device that is used to stimulate electrically a patient's spinal cord to relieve...

  3. Sex differences in the outcomes of stent implantation in mini-swine model.

    Science.gov (United States)

    Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R

    2018-01-01

    Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.

  4. Sustained Release Talazoparib Implants for Localized Treatment of BRCA1-deficient Breast Cancer.

    Science.gov (United States)

    Belz, Jodi E; Kumar, Rajiv; Baldwin, Paige; Ojo, Noelle Castilla; Leal, Ana S; Royce, Darlene B; Zhang, Di; van de Ven, Anne L; Liby, Karen T; Sridhar, Srinivas

    2017-01-01

    Talazoparib, a potent PARP inhibitor, has shown promising clinical and pre-clinical activity by inducing synthetic lethality in cancers with germline Brca1/2 mutations. Conventional oral delivery of Talazoparib is associated with significant off-target effects, therefore we sought to develop new delivery systems in the form of an implant loaded with Talazoparib for localized, slow and sustained release of the drug at the tumor site in Brca1 -deficient breast cancer. Poly(lactic-co-glycolic acid) (PLGA) implants (0.8 mm diameter) loaded with subclinical dose (25 or 50 µg) Talazoparib were fabricated and characterized. In vitro studies with Brca1 -deficient W780 and W0069 breast cancer cells were conducted to test sensitivity to PARP inhibition. The in vivo therapeutic efficacy of Talazoparib implants was assessed following a one-time intratumoral injection in Brca1 Co/Co ;MMTV-Cre;p53 +/- mice and compared to drug-free implants and oral gavage. Immunohistochemistry studies were performed on tumor sections using PCNA and γ-H2AX staining. Sustained release of Talazoparib was observed over 28 days in vitro . Mice treated with Talazoparib implants showed statistically significant tumor growth inhibition compared to those receiving drug-free implants or free Talazoparib orally. Talazoparib implants were well-tolerated at both drug doses and resulted in less weight loss than oral gavage. PARP inhibition in mice treated with Talazoparib implants significantly increased double-stranded DNA damage and decreased tumor cell proliferation as shown by PCNA and γ-H2AX staining as compared to controls. These results demonstrate that localized and sustained delivery of Talazoparib via implants has potential to provide superior treatment outcomes at sub-clinical doses with minimal toxicity in patients with BRCA1 deficient tumors.

  5. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    Science.gov (United States)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  6. Three-dimensional printing and nanotechnology for enhanced implantable materials

    Science.gov (United States)

    Tappa, Karthik Kumar

    Orthopedic and oro-maxillofacial implants have revolutionized treatment of bone diseases and fractures. Currently available metallic implants have been in clinical use for more than 40 years and have proved medically efficacious. However, several drawbacks remain, such as excessive stiffness, accumulation of metal ions in surrounding tissue, growth restriction, required removal/revision surgery, inability to carry drugs, and susceptibility to infection. The need for additional revision surgery increases financial costs and prolongs recovery time for patients. These metallic implants are bulk manufactured and often do not meet patient's requirements. A surgeon must machine (cut, weld, trim or drill holes) them in order to best suit the patient specifications. Over the past few decades, attempts have been made to replace these metallic implants with suitable biodegradable materials to prevent secondary/revision surgery. Recent advances in biomaterials have shown multiple uses for lactic acid polymers in bone implant technology. However, a targeted/localized drug delivery system needs to be incorporated in these polymers, and they need to be customized to treat orthopedic implant-related infections and other bone diseases such as osteomyelitis, osteosarcoma and osteoporosis. Rapid Prototyping (RP) using additive manufacturing (AM) or 3D printing could allow customization of constructs for personalized medicine. The goal of this study was to engineer customizable and biodegradable implant materials that can elute bioactive compounds for personalized medicine and targeted drug delivery. Post-operative infections are the most common complications following dental, orthopedic and bone implant surgeries. Preventing post-surgical infections is therefore a critical need that current polymethylmethacrylate (PMMA) bone cements fail to address. Calcium Phosphate Cements (CPCs) are unique in their ability to crystallize calcium and phosphate salts into hydroxyapatite (HA) and

  7. Intrathecal volume changes in lumbar spinal canal stenosis following extension and flexion: An experimental cadaver study.

    Science.gov (United States)

    Teske, Wolfram; Schwert, Martin; Zirke, Sonja; von Schulze Pellengahr, Christoph; Wiese, Matthias; Lahner, Matthias

    2015-01-01

    The spinal canal stenosis is a common disease in elderly. The thecal sac narrowing is considered as the anatomical cause for the disease. There is evidence that the anatomical proportions of the lumbar spinal canal are influenced by postural changes. The liquor volume shift during these postural changes is a valuable parameter to estimate the dynamic qualities of this disease. The aim of this human cadaver study was the determination of intrathecal fluid volume changes during the lumbar flexion and the extension. A special measuring device was designed and built for the study to investigate this issue under controlled conditions. The measuring apparatus fixed the lumbar spine firmly and allowed only flexion and extension. The dural sac was closed water tight. The in vitro changes of the intrathecal volumes during the motion cycle were determined according to the principle of communicating vessels. Thirteen human cadaver spines from the Institute of Anatomy were examined in a test setting with a continuous adjustment of motion. The diagnosis of the lumbar spinal stenosis was confirmed by a positive computer tomography prior testing. The volume changes during flexion and extension cycles were measured stepwise in a 2 degree distance between 18° flexion and 18° extension. Three complete series of measurements were performed for each cadaver. Two specimens were excluded because of fluid leaks from further investigation. The flexion of the lumbar spine resulted in an intrathecal volume increase. The maximum volume effects were seen in the early flexion positions of 2° and 4°. The spine reclination resulted in a volume reduction. The maximum extension effect was seen between 14° and 16°. According to our results, remarkable volume effects were seen in the early movements of the lumbar spine especially for the flexion. The results support the concept of the spinal stenosis as a dynamic disease and allow a better understanding of the pathophysiology of this

  8. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    Science.gov (United States)

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  9. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  10. Therapy of an incomplete spinal cord injury by intrathecal injection of EPO and subcutaneous injection of EPO, vitamin C and G-CSF.

    Science.gov (United States)

    Bader, Augustinus; Reinhardt, Martin; Beuthe, Achim; Röhl, Klaus; Giri, Shibashish

    2017-01-01

    Spinal cord injury is a rare disease with an incidence about 40 cases per million population in the USA. The most common reasons are traffic accidents, falls, violence and sports. A 53-year-old male patient presented with an incomplete tetraparesis as a result of a spinal cord injury after the accident. It was not possible to treat him with steroids because he was out of the therapeutic time period of 8 hours when he presented to the hospital. The main problem of spinal cord injuries is the secondary injury caused by inflammation and swelling of the spinal cord. To avoid this, the patient was experimentally treated with erythropoietin (EPO) intrathecal and EPO, granulocyte-colony-stimulating factor and vitamin C subcutaneous after his initial spinal cord relief surgery. These drugs might be able to relieve this secondary reaction but were never applied for this indication in human before. This study shows that it could be a promising treatment for spinal cord injuries with potential therapeutic benefits.

  11. Effects of massage therapy on pain and anxiety arising from intrathecal therapy or bone marrow aspiration in children with cancer.

    Science.gov (United States)

    Çelebioğlu, Ayda; Gürol, Ayşe; Yildirim, Zuhal Keskin; Büyükavci, Mustafa

    2015-12-01

    Cancer and its treatment are stressful and reduce the quality of life in children. The aim of this study was to investigate the effect of massage therapy on pain and anxiety arising from intrathecal therapy or bone marrow aspiration in children with cancer. We conducted a controlled pretest/posttest quasi-experimental study at a paediatric oncology unit in Turkey. Twenty-five children were enrolled in this study. Their pain and anxiety were determined using a visual analogue scale. When the pretest and posttest pain and anxiety levels of the groups were compared, no statistically significant difference was found (P > 0.05). It was determined that pain and anxiety levels in the experimental group decreased significantly. This study provides preliminary evidence for the effectiveness in children of massage in reducing pain and anxiety arising from intrathecal therapy or bone marrow aspiration. © 2014 Wiley Publishing Asia Pty Ltd.

  12. Comparative study of two doses of intrathecal dexmedetomidine as adjuvant with low dose hyperbaric bupivacaine in ambulatory perianal surgeries: A prospective randomised controlled study

    Directory of Open Access Journals (Sweden)

    K Sudheesh

    2015-01-01

    Full Text Available Background and Aims: Dexmedetomidine (DMT, as intrathecal adjuvant has been shown to successfully prolong duration of analgesia but delay the motor recovery. Hence, this study was designed to find out the dose of DMT which can provide satisfactory analgesia without prolonging motor block. Methods: A total of 50 patients scheduled for elective perianal surgeries were randomly allocated to Groups C or D (n = 25. Group D received hyperbaric bupivacaine 0.5% 4 mg + DMT 5 μg and Group C received hyperbaric bupivacaine 0.5% 4 mg + DMT 3 μg intrathecally. Onset and duration of sensory and motor blockade, duration of analgesia, time for ambulation and first urination were recorded. Adverse effects if any were noted. Results: Demographic characters, duration of surgery were comparable. The onset of sensory block to S1 was 9.61 ± 5.53 min in Group C compared to 7.69 ± 4.80 min in Group D (P = 0.35. Duration of sensory (145.28 ± 83.17 min – C, 167.85 ± 93.75 min – D, P = 0.5 and motor block (170.53 ± 73.44 min – C, 196.14 ± 84.28 min, P = 0.39 were comparable. Duration of analgesia (337.86 ± 105.11 min – C, 340.78 ± 101.81 min – D, P = 0.9 and time for ambulation (252.46 ± 93.72 min – C, 253.64 ± 88.04 min – D, P = 0.97 were also comparable. One patient in each group had urinary retention requiring catheterization. No other side effects were observed. Conclusion: Intrathecal DMT 3 μg dose does not produce faster ambulation compared to intrathecal DMT 5 μg though it produces comparable duration of analgesia for perianal surgeries.

  13. A COMPARATIVE STUDY OF INTRATHECAL DEXMEDETOMIDINE AND FENTANYL AS ADJUVANTS TO BUPIVACAINE

    Directory of Open Access Journals (Sweden)

    Gollapalli Hanumanth

    2016-02-01

    Full Text Available INTRODUCTION Uncontrolled postoperative pain may produce a range of detrimental acute and chronic effects. Spinal anaesthesia provided by bupivacaine may be too short for providing postoperative analgesia. This study is conducted to evaluate the efficacy of intrathecal fentanyl and intrathecal dexmedetomidine as an adjuvant to hyperbaric bupivacaine with regards to the onset and duration of sensory and motor blockade, as well as postoperative analgesia and adverse effects. Hundred patients aged 18-55 years were randomly divided into two groups, each group consisting of 50 patients of either sex belonging to ASA class I and II posted for elective lower abdominal surgeries were given spinal anaesthesia using bupivacaine 0.5%, heavy 2.5 ml with either fentanyl 25µg (group F or 5µg of preservative free dexmedetomidine (group D. Assessment of the sensory and motor blockade were done at the end of each minute till the maximum level achieved. Measurement of blood pressure, pulse rate, respiratory rate and arterial oxygen saturation were obtained. Postoperatively the patients were observed for the duration of analgesia, time taken for complete regression of sensory blockade to S1 and time taken for complete recovery of motor power. RESULTS Our results showed a statistically highly significant prolongation of sensory and motor blockade, and postoperative analgesia in the dexmedetomidine group compared to the fentanyl group. In dexmedetomidine group four out of fifty patients, and in fentanyl group two out of fifty patients developed hypotension. In dexmedetomidine group five out of fifty patients, and in fentanyl group two out of fifty patients developed bradycardia. Incidence of pruritis is significantly high in fentanyl group.

  14. Magnesium Sulphate and Dexmedetomidine used Intrathecally as Adjuvant to Bupivacaine: A Study

    Directory of Open Access Journals (Sweden)

    Zameer Farooq

    2017-08-01

    Full Text Available Background: Intrathecal adjuvants are used for prolongation of duration of subarachnoid block, and provide adequate analgesia. Aim: To evaluate the onset of sensory and motor block, level of sensory block, highest sensory level and Bromage grade at time of onset, induced by Dexmedetomidine and Magnesium sulphate when given intrathecally with 0.5% hyperbaric Bupivacaine for spinal anaesthesia. Materials and methods: 90 patients, of ASA grade I and grade II, age 18-65 years, of either gender, height 150 cm and above and weight 50 kg to 80 kg, scheduled for lower abdominal and lower limb surgery under spinal anaesthesia. They were randomly assigned according to table of randomization into three groups, 30 patients in each group. Patients in Group A were given 15 mg hyperbaric Bupivacaine and 10 μg (0.1 ml Dexmedetomidine and those in Group B were given 15 mg hyperbaric Bupivacaine and 50 mg (0.1 ml magnesium sulphate. Patients in Group C were given 15 mg hyperbaric Bupivacaine and normal saline (0.1 ml as control. The onset of sensory block, motor block, level of sensory and grade of motor block were recorded at the time of onset. Results: Onset of sensory and motor block was shorter in group Dexmed as compared to other two groups, and prolonged in group magnesium as compared to other two groups. The level of sensory block was higher at the time of onset and grade of motor block was more in group Dexmed than other two groups. Conclusion: Addition of Dexmedetomidine to Bupivacaine shortens the onset time whereas addition of Magnesium delays onset.

  15. Biodegradable hollow fibres for the controlled release of drugs

    NARCIS (Netherlands)

    Schakenraad, J.M.; Oosterbaan, J.A.; Nieuwenhuis, P.; Molenaar, I.; Olijslager, J.; Potman, W.; Eenink, M.J.D.; Feijen, Jan

    1988-01-01

    Biodegradable hollow fibres of poly-l-lactic acid (PLLA) filled with a suspension of the contraceptive hormone levonorgestrel in castor oil were implanted subcutaneously in rats to study the rate of drug release, rate of biodegradation and tissue reaction caused by the implant. The in vivo drug

  16. Cardiovascular effects of intrathecally administered bradykinin in the rat: characterization of receptors with antagonists.

    OpenAIRE

    Lopes, P.; Regoli, D.; Couture, R.

    1993-01-01

    1. The effects of intrathecal (i.t.) pretreatment with selective B1 or B2 kinin receptor antagonists were studied on the cardiovascular response to i.t. injection of bradykinin (BK) in conscious freely moving rats. 2. BK (81 pmol) produced an increase in mean arterial pressure (MAP: 9-13 mmHg) and decrease in heart rate (HR: 20-30 beats min-1) that reached a maximum 2 min after injection. 3. The BK-induced cardiovascular responses were dose-dependently and reversibly reduced by four antagonis...

  17. Buprenorphine implants in medical treatment of opioid addiction.

    Science.gov (United States)

    Chavoustie, Steven; Frost, Michael; Snyder, Ole; Owen, Joel; Darwish, Mona; Dammerman, Ryan; Sanjurjo, Victoria

    2017-08-01

    Opioid use disorder is a chronic, relapsing disease that encompasses use of both prescription opioids and heroin and is associated with a high annual rate of overdose deaths. Medical treatment has proven more successful than placebo treatment or psychosocial intervention, and the partial µ-opioid receptor agonist and κ-opioid receptor antagonist buprenorphine is similar in efficacy to methadone while offering lower risk of respiratory depression. However, frequent dosing requirements and potential for misuse and drug diversion contribute to significant complications with treatment adherence for available formulations. Areas covered: This review describes the development of and preliminary data from clinical trials of an implantable buprenorphine formulation. Efficacy and safety data from comparative studies with other administrations of buprenorphine, including tablets and sublingual film, will be described. Key premises of the Risk Evaluation and Mitigation Strategy program for safely administering buprenorphine implants, which all prescribing physicians must complete, are also discussed. Expert commentary: Long-acting implantable drug formulations that offer consistent drug delivery and lower risk of misuse, diversion, or accidental pediatric exposure over traditional formulations represent a promising development for the effective treatment of opioid use disorder.

  18. Permanent relief from intermittent cold stress-induced fibromyalgia-like abnormal pain by repeated intrathecal administration of antidepressants

    Directory of Open Access Journals (Sweden)

    Mukae Takehiro

    2011-09-01

    Full Text Available Abstract Background Fibromyalgia (FM is characterized by chronic widespread pain, which is often refractory to conventional painkillers. Numerous clinical studies have demonstrated that antidepressants are effective in treating FM pain. We previously established a mouse model of FM-like pain, induced by intermittent cold stress (ICS. Results In this study, we find that ICS exposure causes a transient increase in plasma corticosterone concentration, but not in anxiety or depression-like behaviors. A single intrathecal injection of an antidepressant, such as milnacipran, amitriptyline, mianserin or paroxetine, had an acute analgesic effect on ICS-induced thermal hyperalgesia at post-stress day 1 in a dose-dependent manner. In addition, repeated daily antidepressant treatments during post-stress days 1-5 gradually reversed the reduction in thermal pain threshold, and this recovery was maintained for at least 7 days after the final treatment. In addition, relief from mechanical allodynia, induced by ICS exposure, was also observed at day 9 after the cessation of antidepressant treatment. In contrast, the intravenous administration of these antidepressants at conventional doses failed to provide relief. Conclusions These results suggest that the repetitive intrathecal administration of antidepressants permanently cures ICS-induced FM pain in mice.

  19. 21 CFR 1308.25 - Exclusion of a veterinary anabolic steroid implant product; application.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Exclusion of a veterinary anabolic steroid implant... OF JUSTICE SCHEDULES OF CONTROLLED SUBSTANCES Excluded Veterinary Anabolic Steroid Implant Products § 1308.25 Exclusion of a veterinary anabolic steroid implant product; application. (a) Any person seeking...

  20. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  1. Lumbar neuropathic pain of lower limbs treated by spinal infusion of ziconotide a case – report

    Directory of Open Access Journals (Sweden)

    Luca Quadrino

    2008-09-01

    Full Text Available The Author reports the case of a patient with severe lumbar pain unresponsive to NSAIDs. Initial treatment with tramadol gave poor results and a new protocol with hydromorphone – pregabalin was started. The analgesic response was observed only following high hydromorphone doses, associated with unacceptable side effects. A spinal device for continuous intrathecal infusion was then implanted, in order to administer ziconotide, a new opioid drug. Associated therapy included hydromorphone – pregabalin. At the 4 mcg/die dose ziconotide resulted highly effective (with a VAS reduction pain 6-7 to 2-3 even at 1st day after implantation; in addition at day 10, opioid dose was strongly reduced and pregabalin withdrawn. The treatment was associated with a good tolerability. The encouraging results prompted the Author to test ziconotide in further cases of severe chronic pain.

  2. Spinal conduction block by intrathecal ketamine in dogs.

    Science.gov (United States)

    Iida, H; Dohi, S; Tanahashi, T; Watanabe, Y; Takenaka, M

    1997-07-01

    In addition to its use for intravenous (I.V.) anesthesia, ketamine can provide pain relief in humans when administered spinally. To elucidate the mechanisms of intrathecal (I.T.) ketamine analgesia, we observed differences in the effects of I.V. and I.T. ketamine on intraspinal evoked potentials (ISEPs) in 28 dogs anesthetized with pentobarbital. Bipolar extradural electrodes were inserted at the cervical and lumbar regions of the spinal cord for recording descending ISEPs represented by the two negative deflections, Waves I and II. I.V. ketamine 2 and 10 mg/ kg did not affect the amplitude and latency of Wave I, whereas the large dose (10 mg/kg) significantly decreased the amplitude but not the latency of Wave II. I.T. ketamine 1 and 5 mg/kg caused significant dose-dependent decreases in both Wave I and II amplitudes and prolongations of both Wave I and II latencies. These I.T. effects on ISEPs are consistent with previous in vitro observations that ketamine blocks axonal conduction. We conclude that axonal conduction block may contribute to the analgesic mechanism of I.T. ketamine.

  3. T2-weighted vs. intrathecal contrast-enhanced MR cisternography in the evaluation of CSF rhinorrhea

    International Nuclear Information System (INIS)

    Ecin, Gaye; Oner, A. Yusuf; Tokgoz, Nil; Ucar, Murat; Tali, Turgut; Aykol, Sukru

    2013-01-01

    Background: Endoscopic surgical approach is being more widely used in the treatment of cerebrospinal fluid (CSF) rhinorrhea. Accurate localization of CSF fistulas prior to surgery is essential in increasing the success of dural repair and in decreasing negative or recurrent explorations. Purpose: To evaluate and compare intrathecal contrast medium-enhanced magnetic resonance cisternography (CEMRC) with T2-weighted MR cisternography (T2MRC) in identifying the presence and site of CSF rhinorrhea. Material and Methods: Sixty patients with suspected CSF rhinorrhea underwent MR cisternography including intrathecally enhanced fat-suppressed T1WI in three orthogonal planes and T2WI in the coronal plane. Both set of images were reviewed by two blinded radiologists for the presence and location of CSF leakage. Imaging data were compared with surgical findings and/or beta-2 transferrin testing. Results: With surgery proven CSF leakage in 20 instances as reference, CEMRC detected 18 (90%), whereas T2MRC reported only 13 (65%) correctly. Overall, sensitivity, specificity, positive predictive value, and negative predictive value in detecting CSF fistulas were 92%, 80%, 76%, and 93% for CEMRC, and 56%, 77%, 64%, and 71% for T2MRC, respectively. Conclusion: The minimally invasive CEMRC is an effective method with higher sensitivity and specificity than T2MRC in the evaluation of CSF fistulas

  4. The effect of intrathecal delivery of bone marrow stromal cells on hippocampal neurons in rat model of Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Mina Eftekharzadeh

    2015-05-01

    Full Text Available Objective(s: Intracerebral injection of bone marrow stromal cells (BMSCs is being investigated as a therapeutic tool to prevent Alzheimer's disease (AD. Our aim was to investigate the effects of BMSCs by intrathecal injection in AD rat model. Materials and Methods: BMSCs were obtained from the bone marrow of Wistar rat and transplanted into AD rat model via intrathecal injection. The rat model had received an injection of β amyloid into the hippocampus for histological and immunohistochemical studies. Results: Histological examination of the brains in transplanted rats compared to controls demonstrated the migration of BrdU-labeled BMSCs from the site of delivery, confirmed the differentiation of BMSCs transplanted cells into the cholinergic neurons, and increased number of healthy and decreased number of dark neurons. Conclusion: Our results showed that BMSCs intratechal administration could be a promising method for treatment ofAlzheimer’s disease in rat model.

  5. Diclofenac Sodium Loaded Multicomponent Implant

    Science.gov (United States)

    Nikkola, Lila; Viitanen, Petrus; Ashammakhi, Nureddin

    2008-02-01

    Earlier we have reported on developing DS releasing bioabsorbable rods for inhibition of osteolysis [l]. Due to their unsatisfactory drug release profiles we assessed the use of sintering technique of enhancement of drug release in the current study. Melt extruded PLGA 80/20 rods were compounded 8 wt-% DS. Some rods were self reinforced (SR) and some of them were sterilized to get three different components with different drug release profiles. Different rods were sintered together with heat and pressure. Three different specimen groups with different construction were studied. Thermal properties were analyzed using differential scanning calorimetry (DSC). Changes of IV were performed with capillary analysis and drug release measurements with UV-Vis spectrophotometer. Mechanical strength were measured two weeks, when disintegration occurred. Release rate consisted of 1) sharp jump start peak, 2) second smoother peak, and 3) third smooth peak. Released DS concentrations reached local therapeutic levels and maintained at that stage for 24-36 days. All DS was released during 50-70 days. The drug release from multicomponent implant was more stable and commenced earlier than from initial rods. Such properties were favored ones. Initial shear strength was 82 MPa and it decreased to 15 MPa. The mechanical bonding was sufficient although the components disintegrated relatively fast. By sintering different PLGA/DS components with different release rates it is possible to construct a truly controlled release implant for bone fixation with anti-inflammatory properties.

  6. Intrathecal IgM index correlates with a severe disease course in multiple sclerosis: Clinical and MRI results.

    Science.gov (United States)

    Ozakbas, Serkan; Cinar, Bilge Piri; Özcelik, Pinar; Baser, Hatice; Kosehasanoğullari, Gorkem

    2017-09-01

    Intrathecally synthesized IgM can be seen not only in the cerebrospinal fluid (CSF) in infectious and inflammatory diseases of the central nervous system, but also in that of patients with multiple sclerosis (MS). Intrathecal IgM synthesis in MS seems to be correlated with an unfavorable disease course. In one cross-sectional study, intrathecal synthesis of IgM (IgM index) was found to be correlated with cranial magnetic resonance imaging (MRI) parameters. The purpose of this study was to determine the possible relationship between the IgM index and MRI and clinical parameters. Eighty-one patients with MS (58 female) undergoing lumbar puncture were included in the study. Fifty-one patients had a relapsing-remitting (RR) disease course, while 30 cases were secondary progressive MS (SPMS). IgM was detected in paired CSF and serum specimens using ELISA. The IgM index was calculated using the formula CSF IgM/serum IgM: CSF albumin/serum albumin. IgM indexes higher than 0.1 were considered "increased". All patients underwent brain and whole spinal cord MRI. The IgM index was normal in 43 of the 81 patients (53.1%) and increased in 38 (46.9%). A significant correlation was determined between the IgM index and Expanded Disability Status Scale (EDSS) (r=0.638, p=0.001). Most of the subjects with increased IgM indexes were SPMS patients, 28 having a SPMS course and 10 a RRMS course. Only two patients with SPMS courses had normal IgM indexes. EDSS scores were significantly higher in patients with increased IgM indexes (EDSS 4.3 vs EDSS 2.8, p=0.000). All patients with EDSS >3 had increased IgM indexes. All patients with IgM index values higher than 0.2 IgM had SPMS courses and EDSS >6. Time to onset of the secondary progressive phase of the disease was correlated with IgM index values (p=0.004). IgM index values were also correlated with T1 hypointense lesions (r=0.0431, p=0.008) and Gd enhancing lesions (r=0.0396, p=0.006). Patients with increased IgM indexes also had more

  7. Cerebrospinal fluid IL-12p40, CXCL13 and IL-8 as a combinatorial biomarker of active intrathecal inflammation.

    Directory of Open Access Journals (Sweden)

    Bibiana Bielekova

    Full Text Available Diagnosis and management of the neuroinflammatory diseases of the central nervous system (CNS are hindered by the lack of reliable biomarkers of active intrathecal inflammation. We hypothesized that measuring several putative inflammatory biomarkers simultaneously will augment specificity and sensitivity of the biomarker to the clinically useful range. Based on our pilot experiment in which we measured 18 inflammatory biomarkers in 10-fold concentrated cerebrospinal fluid (CSF derived from 16 untreated patients with highly active multiple sclerosis (MS we selected a combination of three CSF biomarkers, IL-12p40, CXCL13 and IL-8, for further validation.Concentrations of IL-12p40, CXCL13 and IL-8 were determined in a blinded fashion in CSF samples from an initial cohort (n = 72 and a confirmatory cohort (n = 167 of prospectively collected, untreated subjects presenting for a diagnostic work-up of possible neuroimmunological disorder. Diagnostic conclusion was based on a thorough clinical workup, which included laboratory assessment of the blood and CSF, neuroimaging and longitudinal follow-up. Receiver operating characteristic (ROC curve analysis in conjunction with principal component analysis (PCA, which was used to combine information from all three biomarkers, assessed the diagnostic value of measured biomarkers.Each of the three biomarkers was significantly increased in MS and other inflammatory neurological disease (OIND in comparison to non-inflammatory neurological disorder patients (NIND at least in one cohort. However, considering all three biomarkers together improved accuracy of predicting the presence of intrathecal inflammation to the consistently good to excellent range (area under the ROC curve = 0.868-0.924.Future clinical studies will determine if a combinatorial biomarker consisting of CSF IL-12p40, CXCL13 and IL-8 provides utility in determining the presence of active intrathecal inflammation in diagnostically

  8. A randomised controlled trial of the effect of a head-elevation pillow on intrathecal local anaesthetic spread in caesarean section.

    Science.gov (United States)

    Elfil, H; Crowley, L; Segurado, R; Spring, A

    2015-11-01

    A head-elevation pillow places a patient in a ramped posture, which maximises the view of the larynx during laryngoscopy, particularly in obese parturients. In our institution an elevation pillow is used pre-emptively for neuraxial anaesthesia. We hypothesised that head-elevation may impair cephalad spread of local anaesthetic before caesarean section resulting in a lower block or longer time to achieve a T6 level. We aimed to investigate the effect of head-elevation on spread of intrathecal local anaesthetics during anaesthesia for caesarean section. One-hundred parturients presenting for caesarean section under combined spinal-epidural anaesthesia were randomised to either the standard supine position with lateral displacement or in the supine position with lateral displacement on an head-elevation pillow. Each patient received intrathecal hyperbaric bupivacaine 11 mg, morphine 100 μg and fentanyl 15 μg. Patients were assessed for adequacy of sensory block (T6 or higher) at 10 min. Sensory block to T6 was achieved within 10 min in 65.9% of parturients in the Elevation Pillow Group compared to 95.7% in the Control Group (P<0.05). Compared to the Control Group, patients in the Elevation Pillow Group had greater requirements for epidural supplementation (43.5% vs 2.1%, P<0.001) or conversion to general anaesthesia (9.3% vs 0%, P<0.04). Use of a ramped position with an head-elevation pillow following injection of the intrathecal component of a combined spinal-epidural anaesthetic for scheduled caesarean section was associated with a significantly lower block height at 10min. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Five-Year Safety Data for More than 55,000 Subjects following Breast Implantation: Comparison of Rare Adverse Event Rates with Silicone Implants versus National Norms and Saline Implants.

    Science.gov (United States)

    Singh, Navin; Picha, George J; Hardas, Bhushan; Schumacher, Andrew; Murphy, Diane K

    2017-10-01

    The U.S. Food and Drug Administration has required postapproval studies of silicone breast implants to evaluate the incidence of rare adverse events over 10 years after implantation. The Breast Implant Follow-Up Study is a large 10-year study (>1000 U.S. sites) evaluating long-term safety following primary augmentation, revision-augmentation, primary reconstruction, or revision-reconstruction with Natrelle round silicone breast implants compared with national norms and outcomes with saline implants. Targeted adverse events in subjects followed for 5 to 8 years included connective tissue diseases, neurologic diseases, cancer, and suicide. The safety population comprised 55,279 women (primary augmentation, n = 42,873; revision-augmentation, n = 6837; primary reconstruction, n = 4828; and revision-reconstruction, n = 741). No targeted adverse events occurred at significantly greater rates in silicone implant groups versus national norms across all indications. The standardized incidence rate (observed/national norm) for all indications combined was 1.4 for cervical/vulvar cancer, 0.8 for brain cancer, 0.3 for multiple sclerosis, and 0.1 for lupus/lupus-like syndrome. Silicone implants did not significantly increase the risk for any targeted adverse events compared with saline implants. The risk of death was similar with silicone versus saline implants across all indications. The suicide rate (10.6 events per 100,000 person-years) was not significantly higher than the national norm. No implant-related deaths occurred. Results from 5 to 8 years of follow-up for a large number of subjects confirmed the safety of Natrelle round silicone implants, with no increased risk of systemic disease or suicide versus national norms or saline implants. Therapeutic, II.

  10. Technical tips during implantation of selective upper airway stimulation.

    Science.gov (United States)

    Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits

    2018-03-01

    Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Tóth, S.; Koós, M. [Research Institute for Solid State Physics and Optics, Budapest (Hungary); Beiler, B. [Institute of Isotopes, HAS, Budapest (Hungary)

    2009-07-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  12. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Tóth, S.; Koós, M.; Beiler, B.

    2009-01-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  13. Characterization and in vitro release of cyclosporine-A from poly(D,L-lactide-co-glycolide implants obtained by solvent/extraction evaporation

    Directory of Open Access Journals (Sweden)

    Juliana Barbosa Saliba

    2012-01-01

    Full Text Available Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.

  14. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  15. Intrathecal morphine plus general anesthesia in cardiac surgery: effects on pulmonary function, postoperative analgesia, and plasma morphine concentration

    Directory of Open Access Journals (Sweden)

    Luciana Moraes dos Santos

    2009-04-01

    Full Text Available OBJECTIVES: To evaluate the effects of intrathecal morphine on pulmonary function, analgesia, and morphine plasma concentrations after cardiac surgery. INTRODUCTION: Lung dysfunction increases morbidity and mortality after cardiac surgery. Regional analgesia may improve pulmonary outcomes by reducing pain, but the occurrence of this benefit remains controversial. METHODS: Forty-two patients were randomized for general anesthesia (control group n=22 or 400 µg of intrathecal morphine followed by general anesthesia (morphine group n=20. Postoperative analgesia was accomplished with an intravenous, patient-controlled morphine pump. Blood gas measurements, forced vital capacity (FVC, forced expiratory volume (FEV, and FVC/FEV ratio were obtained preoperatively, as well as on the first and second postoperative days. Pain at rest, profound inspiration, amount of coughing, morphine solicitation, consumption, and plasma morphine concentration were evaluated for 36 hours postoperatively. Statistical analyses were performed using the repeated measures ANOVA or Mann-Whiney tests (*p<0.05. RESULTS: Both groups experienced reduced FVC postoperatively (3.24 L to 1.38 L in control group; 2.72 L to 1.18 L in morphine group, with no significant decreases observed between groups. The two groups also exhibited similar results for FEV1 (p=0.085, FEV1/FVC (p=0.68 and PaO2/FiO2 ratio (p=0.08. The morphine group reported less pain intensity (evaluated using a visual numeric scale, especially when coughing (18 hours postoperatively: control group= 4.73 and morphine group= 1.80, p=0.001. Cumulative morphine consumption was reduced after 18 hours in the morphine group (control group= 20.14 and morphine group= 14.20 mg, p=0.037. The plasma morphine concentration was also reduced in the morphine group 24 hours after surgery (control group= 15.87 ng.mL-1 and morphine group= 4.08 ng.mL-1, p=0.029. CONCLUSIONS: Intrathecal morphine administration did not significantly alter

  16. Intraocular Implants for the Treatment of Autoimmune Uveitis

    Directory of Open Access Journals (Sweden)

    Darren J. Lee

    2015-07-01

    Full Text Available Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon.

  17. Biodegradable drug-eluting nanofiber-enveloped implants for sustained release of high bactericidal concentrations of vancomycin and ceftazidime: in vitro and in vivo studies

    Directory of Open Access Journals (Sweden)

    Hsu YH

    2014-09-01

    Full Text Available Yung-Heng Hsu,1,2 Dave Wei-Chih Chen,1 Chun-Der Tai,3 Ying-Chao Chou,1,2 Shih-Jung Liu,2 Steve Wen-Neng Ueng,1 Err-Cheng Chan4 1Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Guishan Township, 2Department of Mechanical Engineering, Chang Gung University, Guishan Township, 3Graduate Institute of Medical Mechatronics, Chang Gung University, Guishan Township, 4School of Medical Technology, Chang Gung University, Guishan Township, Taiwan Abstract: We developed biodegradable drug-eluting nanofiber-enveloped implants that provided sustained release of vancomycin and ceftazidime. To prepare the biodegradable nanofibrous membranes, poly(D,L-lactide-co-glycolide and the antibiotics were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propanol. They were electrospun into biodegradable drug-eluting membranes, which were then enveloped on the surface of stainless plates. An elution method and a high-performance liquid chromatography assay were employed to characterize the in vivo and in vitro release rates of the antibiotics from the nanofiber-enveloped plates. The results showed that the biodegradable nanofiber-enveloped plates released high concentrations of vancomycin and ceftazidime (well above the minimum inhibitory concentration for more than 3 and 8 weeks in vitro and in vivo, respectively. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The bioactivity ranged from 25% to 100%. In addition, the serum creatinine level remained within the normal range, suggesting that the high vancomycin concentration did not affect renal function. By adopting the electrospinning technique, we will be able to manufacture biodegradable drug-eluting implants for the long-term drug delivery of different antibiotics. Keywords: biodegradable nanofiber-enveloped plates, electrospinning, antibiotics, release characteristics

  18. [In vitro study on intrathecal application of 5-fluoro-2'-deoxyuridine (FdUrd) for meningeal dissemination of malignant tumor].

    Science.gov (United States)

    Nakagawa, H; Yamada, M; Fukushima, M; Shimizu, K; Ikenaka, K

    1998-09-01

    To evaluate the possible clinical intrathecal use of 5-fluoro-2'-deoxyuridine (FdUrd) for malignant brain tumors, its anti-tumor activity and neurotoxicity were compared with that of 5-fluorouracil (5-FU) and 5-fluorouridine (FUrd) in vitro. FdUrd showed good tumoricidal activity against cultured mouse 203 glioma cells and rat Walker 256 carcinoma cells as well as A172 human glioblastoma cells. Daoy human medulloblastoma cells and CADO-LC4 human lung cancer cells. It also showed less toxicity for primary cultures of neurons from C57/BL6 mouse and human embryo compared to 5-FU and FUrd. Thymidine phosphorylase (TPase) and thymidine kinase (TK), key enzymes for metabolism of 5-FU derivatives, were measured in cerebrospinal fluid (CSF). TPase or TK activity was detected in the CSF of hardly any patients with malignant brain tumors including meningeal carcinomatosis. These data indicated that the CSF is a favorable site for FdUrd chemotherapy, because the rate of conversion of FdUrd injected to 5-FU would be minimal. In conclusion, FdUrd may be potentially useful for intrathecal treatment of meningeal carcinomatosis.

  19. Prophylaxis of meningosis leukemia via intrathecal radioactive colloid gold injection

    Energy Technology Data Exchange (ETDEWEB)

    Angelov, A; Uzunov, I; Marshavelova, J [Meditsinski Fakultet, Plovdiv (Bulgaria)

    1979-01-01

    Prophylaxis against meningosis leukemia (ML) via intrathecal radioactive colloid gold injection was carried out for a period of three years (January 1974 - September 1976) in 21 children with acute lymphoblast leukemia (ALL). The analysis of those patients after one relatively long period of observation (28 months after the last case) reveals that ML developed as a primary isolated manifestation of a recurrence in three children, i.e. in 14.2 per cent versus 68 per cent in the control group without prophylaxis. In another child ML development is in parallel with bone marrow recurrence. The reduction of ML incidence is accompanied with a prolongation of the first remission (in 24 per cent over 2 years and 6 months) and a lengthening of survival for 50 per cent of the patients (62 per cent of the treated patients are alive two years and 4 months during the period of observation). The advantages of the prophylaxis with radioactive colloid gold is emphasized in comparison with the other prophylactic programmes.

  20. Diagnosis of central nervous system relapse of pediatric acute lymphoblastic leukemia: Impact of routine cytological CSF analysis at the time of intrathecal chemotherapy.

    Science.gov (United States)

    Gassas, Adam; Krueger, Joerg; Alvi, Saima; Sung, Lillian; Hitzler, Johanne; Lieberman, Lani

    2014-12-01

    Despite the success of central nervous system (CNS) directed therapy in pediatric acute lymphoblastic leukemia (ALL), relapse involving the CNS continues to be observed in 5-10% of children when utilizing standard intrathecal prophylactic chemotherapy. While most pediatric ALL treatment protocols mandate regular lumbar punctures (LP) for the intrathecal injection of chemotherapy, the value of routine cytological analysis of cerebrospinal fluid (CSF) during therapy is unknown. Our objective was to assess the diagnostic value of routine CSF analysis during ALL therapy. To allow for at least 10 years of follow up from ALL diagnosis, children (0-18 years) with ALL diagnosed and treated at SickKids, Toronto, Canada between 1994-2004 were studied. Medical records of patients with CNS relapse were examined to determine whether CNS relapse was diagnosed based on cytology of a routinely obtained CSF sample, a CSF sample obtained because of signs and symptoms or a CSF sample obtained after the diagnosis of a bone marrow relapse. Of 494 children treated for ALL, 31 (6.6%) developed a relapse of ALL involving the CNS. Twenty-two had an isolated CNS relapse and nine had a combined bone marrow and CNS relapse. Among patients with isolated CNS relapse, 73% (16/22) were diagnosed based on routine CSF samples obtained from asymptomatic children. Conversely, 89% (8/9) of children with combined bone marrow and CNS relapse presented with symptoms and signs that prompted CSF examination. Routine CSF examination at the time of LP for intrathecal chemotherapy is useful in detecting CNS relapse. © 2014 Wiley Periodicals, Inc.

  1. Distribution of label after intrathecal administration of 125I-substance P in the rat

    International Nuclear Information System (INIS)

    Cridland, R.A.; Yashpal, K.; Romita, V.V.; Gauthier, S.; Henry, J.L.

    1987-01-01

    Despite the widespread use of the intrathecal route for the administration of neuroactive agents, little is known about the penetration of these agents into the spinal cord. In the present study, 125 I-substance P was injected via a spinal catheter to the thoracic or sacro-coccygeal spinal cord in the rat (350-400 g) anesthetized with urethane (2.5 g/kg). Spinal cords were removed rapidly at 1 or 10 min after injection and immediately frozen in CCl 2 F 2 . Frozen sections, 20 micron thick, were cut and mounted for autoradiography. Autoradiographs of transverse sections demonstrated that the label penetrated 700 to 1800 micron from the surface of the spinal cord at both levels. In longitudinal sections, this penetration extended about 0.5 cm rostrally and caudally from the site of injection. Serial autoradiographs of transverse sections showed a similar penetration rostro-caudally. In addition, venous blood samples were taken at 1, 6, 11 and 16 min after injection of the labelled peptide. Quantification of the radioactivity in the samples revealed that 0.8 to 3.5% of the total CPM injected had passed into the general circulation at these times. These data indicate that after intrathecal administration of radiolabelled substance P, the label penetrates into the grey matter of the spinal cord to presumed sites of action. They also suggest that the rostro-caudal extent of penetration is more localized than suggested from earlier studies which looked only at levels of radioactivity in pieces of whole spinal cord. Finally, our study has indicated that passage of label into the circulation is negligible at least for substance P

  2. In situ epicatechin-loaded hydrogel implants for local drug delivery ...

    African Journals Online (AJOL)

    induce apoptosis and cell cycle arrest in a wide array of cell lines, and protect ... attenuated ischaemic brain injury and inhibition ..... biodegradable smart implants for tissue regeneration after spinal ... Synthetic hydrogels for controlled stem cell.

  3. Intrathecal chemotherapy for refractory disseminated medulloblastoma.

    Science.gov (United States)

    Yoshimura, Junichi; Nishiyama, Kenichi; Mori, Hiroshi; Takahashi, Hideaki; Fujii, Yukihiko

    2008-05-01

    To analyze the effect of intrathecal (IT) chemotherapy for disseminated medulloblastoma. Twenty-one patients received IT chemotherapy using the chemotherapeutic agents of methotrexate (MTX) and nitrosoureas (ACNU, MCNU) including nine patients for residual leptomeningeal lesions after initial surgery and radiation, and 12 for a recurrence with leptomeningeal dissemination. Of these 21 patients, 12 received a lumbar and/or ventricular bolus injection of the chemotherapeutic agents, one received the ventriculolumbar perfusion of the agents, and eight received both the perfusion and bolus injection. The doses ranged from 6-7 mg/m(2) of ACNU for perfusion and 3-3.5 mg/m(2) of ACNU, MCNU, or MTX for the bolus injection, and the cycles were administered from 3 to 12 times for perfusion and from 5 to 54 times for the bolus injection. The effects of chemotherapy were assessed by both radiological and cytological examinations, and the clinical symptoms were also assessed. Radiological and/or cytological responses were observed in 10 of 21 patients (47.6%), including seven cases demonstrating a complete remission. The 5-year overall survival rate and 5-year survival rate after dissemination were 61.5 and 46.4%, respectively. Five patients who received a lumbar bolus injection of nitrosoureas experienced paraplegia and double incontinence. One patient who received a ventricular injection of nitrosoureas experienced truncal ataxia. IT chemotherapy was found to be effective in some cases with refractory disseminated medulloblastoma and it seems to be an appropriate treatment choice for leptomeningeal recurrence. However, the frequent bolus injections of nitrosoureas should be avoided to prevent the side effects.

  4. Ethylene vinyl acetate (EVA) as a new drug carrier for 3D printed medical drug delivery devices

    DEFF Research Database (Denmark)

    Genina, Natalja; Hollander, Jenny; Jukarainen, Harri

    2016-01-01

    The main purpose of this work was to investigate the printability of different grades of ethylene vinyl acetate (EVA) copolymers as new feedstock material for fused-deposition modeling (FDM™)-based 3D printing technology in fabrication of custom-made T-shaped intrauterine systems (IUS......) and subcutaneous rods (SR). The goal was to select an EVA grade with optimal properties, namely vinyl acetate content, melting index, flexural modulus, for 3D printing of implantable prototypes with the drug incorporated within the entire matrix of the medical devices. Indomethacin was used as a model drug...... affected the drug release profiles from the filaments and printed prototype products: faster release from the prototypes over 30 days in the in vitro tests. To conclude, this study indicates that certain grades of EVA were applicable feedstock material for 3D printing to produce drug-loaded implantable...

  5. A Microfluidic Ion Pump for In Vivo Drug Delivery

    KAUST Repository

    Uguz, Ilke

    2017-05-15

    Implantable devices offer an alternative to systemic delivery of drugs for the treatment of neurological disorders. A microfluidic ion pump (µFIP), capable of delivering a drug without the solvent through electrophoresis, is developed. The device is characterized in vitro by delivering γ-amino butyric acid to a target solution, and demonstrates low-voltage operation, high drug-delivery capacity, and high ON/OFF ratio. It is also demonstrated that the device is suitable for cortical delivery in vivo by manipulating the local ion concentration in an animal model and altering neural behavior. These results show that µFIPs represent a significant step forward toward the development of implantable drug-delivery systems.

  6. Effect of Intrathecal Bupivacaine Dose on the Success of External Cephalic Version for Breech Presentation: A Prospective, Randomized, Blinded Clinical Trial.

    Science.gov (United States)

    Chalifoux, Laurie A; Bauchat, Jeanette R; Higgins, Nicole; Toledo, Paloma; Peralta, Feyce M; Farrer, Jason; Gerber, Susan E; McCarthy, Robert J; Sullivan, John T

    2017-10-01

    Breech presentation is a leading cause of cesarean delivery. The use of neuraxial anesthesia increases the success rate of external cephalic version procedures for breech presentation and reduces cesarean delivery rates for fetal malpresentation. Meta-analysis suggests that higher-dose neuraxial techniques increase external cephalic version success to a greater extent than lower-dose techniques, but no randomized study has evaluated the dose-response effect. We hypothesized that increasing the intrathecal bupivacaine dose would be associated with increased external cephalic version success. We conducted a randomized, double-blind trial to assess the effect of four intrathecal bupivacaine doses (2.5, 5.0, 7.5, 10.0 mg) combined with fentanyl 15 μg on the success rate of external cephalic version for breech presentation. Secondary outcomes included mode of delivery, indication for cesarean delivery, and length of stay. A total of 240 subjects were enrolled, and 239 received the intervention. External cephalic version was successful in 123 (51.5%) of 239 patients. Compared with bupivacaine 2.5 mg, the odds (99% CI) for a successful version were 1.0 (0.4 to 2.6), 1.0 (0.4 to 2.7), and 0.9 (0.4 to 2.4) for bupivacaine 5.0, 7.5, and 10.0 mg, respectively (P = 0.99). There were no differences in the cesarean delivery rate (P = 0.76) or indication for cesarean delivery (P = 0.82). Time to discharge was increased 60 min (16 to 116 min) with bupivacaine 7.5 mg or higher as compared with 2.5 mg (P = 0.004). A dose of intrathecal bupivacaine greater than 2.5 mg does not lead to an additional increase in external cephalic procedural success or a reduction in cesarean delivery.

  7. Intrathecal administration of rapamycin inhibits the phosphorylation of DRG Nav1.8 and attenuates STZ-induced painful diabetic neuropathy in rats.

    Science.gov (United States)

    He, Wan-You; Zhang, Bin; Xiong, Qing-Ming; Yang, Cheng-Xiang; Zhao, Wei-Cheng; He, Jian; Zhou, Jun; Wang, Han-Bing

    2016-04-21

    The mammalian target of rapamycin (mTOR) is a key regulator of mRNA translation and protein synthesis, and it is specifically inhibited by rapamycin. In chronic pain conditions, mTOR-mediated local protein synthesis is crucial for neuronal hyperexcitability and synaptic plasticity. The tetrodotoxin-resistant (TTX-R) sodium channel Nav1.8 plays a major role in action potential initiation and propagation and cellular excitability in DRG (dorsal root ganglion) neurons. In this study, we investigated if mTOR modulates the phosphorylation of Nav1.8 that is associated with neuronal hyperexcitability and behavioral hypersensitivity in STZ-induced diabetic rats. Painful diabetic neuropathy (PDN) was induced in Sprague-Dawley rats by intraperitoneal injection with streptozotocin (STZ) at 60mg/kg. After the onset of PDN, the rats received daily intrathecal administrations of rapamycin (1μg, 3μg, or 10μg/day) for 7 days; other diabetic rats received the same volumes of dimethyl sulfoxide (DMSO). Herein, we demonstrate a marked increase in protein expression of total mTOR and phospho-mTOR (p-mTOR) together with the up-regulation of phosphor-Nav1.8 (p-Nav1.8) prior to the mechanical withdrawal threshold reaching a significant reduction in dorsal root ganglions (DRGs). Furthermore, the intrathecal administration of rapamycin, inhibiting the activity of mTOR, suppressed the phosphorylation of DRG Nav1.8, reduced the TTX-R current density, heightened the voltage threshold for activation and lowered the voltage threshold for inactivation and relieved mechanical hypersensitivity in diabetic rats. An intrathecal injection (i.t.) of rapamycin inhibited the phosphorylation and enhanced the functional availability of DRG Nav1.8 attenuated STZ-induced hyperalgesia. These results suggest that rapamycin is a potential therapeutic intervention for clinical PDN. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Intrathecal Fentanyl for Labour Analgesia in a Patient with Severe Mitral Stenosis and Atrial Fibrillation in Advanced Stage of Labour-Case Report

    Directory of Open Access Journals (Sweden)

    Vaijayanti Nitin Gadre

    2013-12-01

    Full Text Available Labour is an intensely painful experience and puts considerable physiological stress on the circulation. A case of rheumatic valvular heart disease with severe mitral stenosis in atrial fibrillation is discussed here in which analgesia with intrathecal fentanyl proved beneficial given during the advanced first stage of labour.

  9. Tumor Lysis Syndrome (TLS following intrathecal chemotherapy in a child with acute myelogenous leukemia (AML

    Directory of Open Access Journals (Sweden)

    Chana L. Glasser, MD

    2017-01-01

    Full Text Available Tumor Lysis Syndrome (TLS is a well-known complication of induction therapy for hematologic malignancies. It is characterized by rapid breakdown of malignant white blood cells (WBCs leading to metabolic derangements and serious morbidity if left untreated. Most commonly, TLS is triggered by systemic chemotherapy, however, there have been case reports of TLS following intrathecal (IT chemotherapy, all in patients with acute lymphoblastic leukemia (ALL/lymphoma. Here, we report the first case of a patient with acute myelogenous leukemia (AML who developed TLS following a single dose of IT cytosine arabinoside (Ara-C.

  10. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  11. Fabrication of drug eluting implants: study of drug release mechanism from titanium dioxide nanotubes

    International Nuclear Information System (INIS)

    Hamlekhan, Azhang; Shokuhfar, Tolou; Sinha-Ray, Suman; Yarin, Alexander L; Takoudis, Christos; Mathew, Mathew T; Sukotjo, Cortino

    2015-01-01

    Formation of titanium dioxide nanotubes (TNTs) on a titanium surface holds great potential for promoting desirable cellular response. However, prolongation of drug release from these nano-reservoirs remains to be a challenge. In our previous work TNTs were successfully loaded with a drug. In this study the effect of TNTs dimensions on prolongation of drug release is quantified aiming at the introduction of a simple novel technique which overcomes complications of previously introduced methods. Different groups of TNTs with different lengths and diameters are fabricated. Samples are loaded with a model drug and rate of drug release over time is monitored. The relation of the drug release rate to the TNT dimensions (diameter, length, aspect ratio and volume) is established. The results show that an increase in any of these parameters increases the duration of the release process. However, the strongest parameter affecting the drug release is the aspect ratio. In fact, TNTs with higher aspect ratios release drug slower. It is revealed that drug release from TNT is a diffusion-limited process. Assuming that diffusion of drug in (Phosphate-Buffered Saline) PBS follows one-dimensional Fick’s law, the theoretical predictions for drug release profile is compatible with our experimental data for release from a single TNT. (paper)

  12. Magnetically induced localized on-demand drug delivery

    NARCIS (Netherlands)

    Rovers, S.A.

    2010-01-01

    Externally triggered on-demand drug release from an implant can significantly improve the efficiency of the drug therapy since it enables the patient or physician to control the dosing to the patient’s needs and releases the drug only at the required location in the human body. Therefore, patient

  13. The Austrian breast implant register: recent trends in implant-based breast surgery.

    Science.gov (United States)

    Wurzer, Paul; Rappl, Thomas; Friedl, Herwig; Kamolz, Lars-Peter; Spendel, Stephan; Hoflehner, Helmut; Parvizi, Daryousch

    2014-12-01

    Due to the fact that the number of breast implant surgeries for cosmetic and medical purposes is rising yearly, a discussion about the quality of service for both patients and physicians is more important than ever. To this end, we reviewed the Austrian Breast Implant Register with one specific question in mind: What are the trends? In the statistical analysis of the Austrian Breast Implant Register, we were able to identify 13,112 registered breast implants between 2004 and 2012. The whole dataset was then divided into medical and cosmetic groups. We focused on device size, surface characteristics, filling material, device placement and incision site. All factors were considered for all examined years. In summary, the most used device had a textured surface (97 %) and silicone gel as the filling material (93 %). The mean size of implants for the cosmetic group was 240 cc, placement was submuscular (58 %) and the incision site was inframammary (67 %). In the medical group, the mean size was 250 cc. Yearly registrations had their peak in 2008 (1,898 registered devices); from this year on, registrations decreased annually. A slight trend away from subglandular placement in the cosmetic group was noted. Also, the usage of implants with polyurethane surface characteristics has increased since 2008. The smooth surface implants had a peak usage in 2006 and their usage decreased steadily from then on whereas the textured surface was steady over the years. Keeping the problems related to the quality of breast implants in mind, we could recommend an obligatory national register. Organisations of surgeons and governments should develop and establish these registers. Furthermore, an all-encompassing international register should be established by the European Union and the American FDA (Food and Drug Administration); this might be useful in comparing the individual country registers and also would help in delivering "evidence based" medicine in cosmetic and medical procedures

  14. Localization and Tracking of Implantable Biomedical Sensors

    Directory of Open Access Journals (Sweden)

    Ilknur Umay

    2017-03-01

    Full Text Available Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems.

  15. Clearance from cerebrospinal fluid of intrathecally administered beta-endorphin in monkeys

    International Nuclear Information System (INIS)

    Lee, V.C.; Burns, R.S.; Dubois, M.; Cohen, M.R.

    1984-01-01

    Five adult male monkeys (Macaca mulatta) weighing 7.1-9.9 kg were given synthetic human beta-endorphin (800 micrograms) and [ 14 C]methoxy-inulin (50 microCi) in 400 microliters of normal saline intrathecally. Serial samples of cerebrospinal fluid were drawn through a previously positioned indwelling spinal catheter and were assayed for concentrations of beta-endorphin (determined by radioimmunoassay) and inulin (determined by liquid scintillation counter). Spinal fluid concentrations of beta-endorphin and inulin peaked and declined in a parallel manner. The clearance ratio (calculated from the reciprocal of the ratio of the areas under the respective curves of elimination of the two species) remained remarkably similar from animal to animal, giving a mean value of 1.060 +/- 0.090 (SEM). This ratio, being near unity, suggests that beta-endorphin is eliminated from spinal fluid in a fashion similar to that of inulin, which is removed exclusively by bulk absorption

  16. Exacerbation of electrical storm subsequent to implantation of a right vagal stimulator.

    Science.gov (United States)

    Shalaby, Alaa A; El-Saed, Aiman; Nemec, Jan; Moossy, John J; Balzer, Jeffrey R

    2007-12-01

    A patient with advanced ischemic cardiomyopathy underwent implantation of a vagal stimulator in an attempt to control recurrent drug refractory ventricular arrhythmia. Electrical storm was exacerbated after the implant and continued after neurostimulation was discontinued. The report aims to provide a cautionary note to application of vagal stimulation for control of cardiac arrhythmia.

  17. Intrathecal fentanyl abolishes the exaggerated blood pressure response to cycling in hypertensive men

    DEFF Research Database (Denmark)

    Barbosa, Thales C; Vianna, Lauro C; Fernandes, Igor A

    2016-01-01

    . In the present study, we tested whether the attenuation of these neural signals in hypertensive patients could normalize their abnormal increase in blood pressure during physical activity. Attenuation of the neural signals from the leg muscles with intrathecal fentanyl injection reduced the blood pressure...... of fentanyl, a μ-opioid receptor agonist, aiming to attenuate the central projection of opioid-sensitive group III and IV muscle afferent nerves. The cardiovascular response to exercise of these subjects was compared with that of six normotensive men. During cycling, the hypertensive group demonstrated...... an exaggerated increase in blood pressure compared to the normotensive group (mean ± SEM: +17 ± 3 vs. +8 ± 1 mmHg, respectively; P 0.05). Fentanyl inhibited the blood pressure response to exercise...

  18. Long term effect (more than five years) of intrathecal baclofen on impairment, disability, and quality of life in patients with severe spasticity of spinal origin

    NARCIS (Netherlands)

    Zahavi, A; Geertzen, JHB; Middel, B; Staal, M; Rietman, JS

    2004-01-01

    Objectives: To evaluate long term change in impairment, disability, and health related functional status in patients with severe spasticity who received intrathecal baclofen. Methods: A long term ( more than five years) observational longitudinal follow up study assessing 21 patients who received

  19. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  20. Intrathecal tramadol as and adjuvant in subrachnoid block to prolong the duration of analgesia

    International Nuclear Information System (INIS)

    Zahid, F.; Tarar, H. M.; Tariq, M.; Nazir, H.; Zafar, I.; Munir, S.

    2017-01-01

    Objective: To assess the effect of intrathecal tramadol added to bupivacaine to prolong the duration of analgesia in subarachnoid block for lower limb orthopedic surgeries. Study Design: Randomized controlled trial. Place and Duration of Study: Anesthesia department of Combined Military Hospital Sialkot, from Nov 2015 to Apr 2016. Material and Methods: Patients were selected by non-probability consecutive sampling. One hundred and fifty patients from American Society of Anesthesiologists (ASA) I, II and III category fulfilling inclusion criteria undergoing various lower limb orthopedic surgeries were divided into two groups by lottery system. Group tramadol bupivacaine (TB) received 25mg (1 ml) of tramadol plus 2ml (10mg) of 0.5 percent bupivacaine while group bupivacaine alone (SB) received 1 ml normal saline plus 2ml (10mg) of 0.5 percent bupivacaine. Time to first analgesia request was noted as a measure of duration of analgesia. Time of onset of sensory block level and peak sensory block level and time to reach the peak sensory block level were also noted. Quality of anesthesia was compared among two groups. Data were analyzed by using SPSS version 22. Results: Four patients were excluded from the study. The duration of anesthesia was effectively prolonged in group TB 181.56 ± 12.42 mins as compared to group SB 120.93 ± 15.54 mins. VAS score was significantly lower in group TB. Higher peak sensory block levels (T6) were achieved in group TB as compared to group SB. However time to reach the peak sensory block levels were significantly longer in group TB. (4.5 ± 0.47mins vs 3.09 ± 0.54 mins). Conclusion: This study showed that intrathecal tramadol (25mg) can safely be used along with bupivacaine in subarachnoid blockade to prolong the duration of analgesia and improve the quality of anesthesia as well. (author)

  1. Biocompatibility and biodegradation studies of subconjunctival implants in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Yan Peng

    Full Text Available Sustained ocular drug delivery is difficult to achieve. Most drugs have poor penetration due to the multiple physiological barriers of the eye and are rapidly cleared if applied topically. Biodegradable subconjunctival implants with controlled drug release may circumvent these two problems. In our study, two microfilms (poly [d,l-lactide-co-glycolide] PLGA and poly[d,l-lactide-co-caprolactone] PLC were developed and evaluated for their degradation behavior in vitro and in vivo. We also evaluated the biocompatibility of both microfilms. Eighteen eyes (9 rabbits were surgically implanted with one type of microfilm in each eye. Serial anterior-segment optical coherence tomography (AS-OCT scans together with serial slit-lamp microscopy allowed us to measure thickness and cross-sectional area of the microfilms. In vitro studies revealed bulk degradation kinetics for both microfilms, while in vivo studies demonstrated surface erosion kinetics. Serial slit-lamp microscopy revealed no significant inflammation or vascularization in both types of implants (mean increase in vascularity grade PLGA50/50 12±0.5% vs. PLC70/30 15±0.6%; P = 0.91 over a period of 6 months. Histology, immunohistochemistry and immuno-fluorescence also revealed no significant inflammatory reaction from either of the microfilms, which confirmed that both microfilms are biocompatible. The duration of the drug delivery can be tailored by selecting the materials, which have different degradation kinetics, to suit the desired clinical therapeutic application.

  2. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  3. Current Trend of Antimicrobial Prescription for Oral Implant Surgery Among Dentists in India.

    Science.gov (United States)

    Datta, Rahul; Grewal, Yasmin; Batth, J S; Singh, Amandeep

    2014-12-01

    The aim of our study was to evaluate antimicrobial prescription behaviour amongst dentists performing oral implant surgery in India. Dentists performing oral implant surgery from different parts of India were personally approached during various national events such as conferences and academic meetings and information regarding their prescription habits for antimicrobial agents in routine oral implant surgery was collected using a structured questionnaire. Out of a total sample of 332 dentists, 85.5 % prescribed 17 different groups or combinations of antibiotics routinely for oral implant surgery in the normal healthy patient. Majority preferred the peri-operative protocol of drug therapy (72.2 %) with variable and prolonged duration of therapy after surgery, ranging from 3 to 10 days. An antimicrobial mouthwash was routinely prescribed by all the doctors (14.5 %) not in favour of prescribing antimicrobials in a normal healthy patient. Our findings suggest that there is a trend of antimicrobial agent misuse by dentists performing oral implant surgery in India, both in terms of drugs used and the protocols prescribed. The majority of these dentists prescribed a variety of antimicrobial agents for prolonged durations routinely even in the normal, healthy patients.

  4. Comparative Study of Constant Dose Intrathecal Hypobaric Levobupivacaine with Varying Baricities in Lower Limb Surgeries.

    Science.gov (United States)

    Biji, K P; Sunil, M; Ramadas, K T

    2017-01-01

    Hypobaric spinal anesthesia is advantageous for unilateral lower extremity fractures as it obviates pain of lying on fractured limb for performing subarachnoid block. This study compares block characteristics and complications of three different baricities of constant dose intrathecal hypobaric levobupivacaine to determine an optimum baricity. One-twenty American Society of Anesthesiologists Physical Status 1 and 2 patients aged 18-65 years undergoing unilateral lower limb surgeries were divided into three equal groups for this prospective cohort study. To 2 mL intrathecal 0.5% isobaric levobupivacaine (10 mg), 0.4 mL, 0.6 mL, and 0.8 mL of distilled water were added in Groups A, B, and C, respectively. Baricities of Groups A, B, and C are 0.999294, 0.998945, and 0.998806, respectively. Development of sensory and motor block was assessed by the pinprick method and Bromage scale, respectively. The total duration of analgesia and complications were noted. Mean, standard error, one-way ANOVA, and Bonferroni were used to analyze quantitative variables; proportions and Chi-square tests for qualitative variables. Demographic parameters, motor block of operated limb, and complications were comparable. Group C had the fastest onset of sensory block (10.10 min) and maximum duration of analgesia (478.97 min; P < 0.001); but high sensory levels in 48.7%. Group B had T 10 sensory level in 92.5%; onset comparable to Group C ( P = 0.248), and reasonable duration of analgesia (332.50 min). Group A had inadequate sensory levels, slow onset, and early regression. Group B (baricity - 0.998945) has better block characteristics among three groups compared.

  5. Glycerol gelatin for 3D-printing of implants using a paste extrusion technique

    Directory of Open Access Journals (Sweden)

    Kempin Wiebke

    2017-09-01

    Full Text Available Fused deposition modeling as an additive manufacturing technique has gained great popularity for the fabrication of medical devices as well as pharmaceutical dosage forms over the last years. Particularly the variety of geometries that can be printed determines the attractiveness of this technique enabling a shape adaption of e.g. implants. In the presented work the soft hydrogel material glycerol gelatin was investigated towards its applicability in 3D-printing as an alternative to the commonly applied and mostly rigid polyesters. Model implants loaded with the model drug quinine and with the shape of a hollow cylinder were printed via an extrusion based technique utilizing the piston feed in a hydrogel filled heatable syringe. Glycerol gelatin hydrogels need to be crosslinked to avoid gel-sol-transition at body temperature. For this purpose three different crosslinking methods (insertion, dipping, spraying with 1-ethyl-3-(3-dimethylaminopropyl carbodiimide (EDC and N-hydroxysuccinimide (NHS were evaluated regarding their crosslinking efficiency and drug losses during the crosslinking process. Dipping of the implant into an aqueous solution with at least 50 mM EDC and 10 mM NHS was found to be the most efficient crosslinking technique in conjunction with a smaller drug loss during processing compared to inserting. However, the use of hydrogels also causes problems as an intense and highly variable swelling of the printed structures during crosslinking (120.7 % ± 11.9 % for 10 times dipping in 50mM EDC/10 mM NHS and a great dependency of the volume on storage conditions complicate the preparation of tailor-made implants. The release of the model drug quinine from printed and crosslinked implants was fast and nearly completed within 6 hours.

  6. [Safety profile of etonogestrel contraceptive implant (Nexplanon® and Implanon®) reported in France].

    Science.gov (United States)

    Simon, C; Agier, M S; Béné, J; Muller, C; Vrignaud, L; Marret, H; Jonville-Bera, A P

    2016-11-01

    The aim of the study was to assess the incidence of adverse effects (AE) reported with etonogestrel contraceptive implant in France (Implanon ® and Nexplanon ® ). All cases of AE or unintended pregnancies reported to health authorities or to the firm were analyzed. During 10 years, 5433 AE and 789 unintended pregnancies were reported. Only 388 (7 %) were serious. There were 1137 reports of difficulties to remove, failure to locate or migration, 430 of insertion difficulties and 203 of deformation or expulsion of the implant. Among other AE, the most common were 1694 gynecological AE, 524 skin reactions and 437 metabolic AE. Since the marketing of Nexplanon ® which causes less deep insertions, the incidence of migrations, removal or insertion difficulties has decreased overall (0.92 vs. 1.31/1000 patients), particularly the incidence of removal difficulties, location failures or migrations (0.12 vs 1.01/1000). The infrequent but serious AE were infectious complications at the implant site and pregnancies. When the circumstances of the pregnancy were known, the contraceptive failure was due to the apparent inefficiency of the implant (n=224), to a technique failure (n=203) or to a drug-drug interaction (n=59). This study confirms that AE of this implant are frequent but not serious, except for the pregnancies. The incidence of complications related to insertion decreased with Nexplanon ® . Among other preventable AE, unintended pregnancies due to a drug-drug interaction would require to be better known by the practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  8. Doxycycline-loaded coaxial nanofiber coating of titanium implants enhances osseointegration and inhibits Staphylococcus aureus infection.

    Science.gov (United States)

    Song, Wei; Seta, Joseph; Chen, Liang; Bergum, Christopher; Zhou, Zhubin; Kanneganti, Praveen; Kast, Rachel E; Auner, Gregory W; Shen, Ming; Markel, David C; Ren, Weiping; Yu, Xiaowei

    2017-07-05

    Few studies have been reported that focus on developing implant surface nanofiber (NF) coating to prevent infection and enhance osseointegration by local drug release. In this study, coaxial doxycycline (Doxy)-doped polycaprolactone/polyvinyl alcohol (PCL/PVA) NFs were directly deposited on a titanium (Ti) implant surface during electrospinning. The interaction of loaded Doxy with both PVA and PCL NFs was characterized by Raman spectroscopy. The bonding strength of Doxy-doped NF coating on Ti implants was confirmed by a stand single-pass scratch test. The improved implant osseointegration by PCL/PVA NF coatings in vivo was confirmed by scanning electron microscopy, histomorphometry and micro computed tomography (μCT) at 2, 4 and 8 weeks after implantation. The bone contact surface (%) changes of the NF coating group (80%) is significantly higher than that of the no NF group (coating effectively inhibited bacterial infection and enhanced osseointegration in an infected (Staphylococcus aureus) tibia implantation rat model. Doxy released from NF coating inhibited bacterial growth up to 8 weeks in vivo. The maximal push-in force of the Doxy-NF coating (38 N) is much higher than that of the NF coating group (6.5 N) 8 weeks after implantation (p coating doped with Doxy and/or other drugs have great potential in enhancing implant osseointegration and preventing infection.

  9. Clearance from cerebrospinal fluid of intrathecally administered beta-endorphin in monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Lee, V.C.; Burns, R.S.; Dubois, M.; Cohen, M.R.

    1984-05-01

    Five adult male monkeys (Macaca mulatta) weighing 7.1-9.9 kg were given synthetic human beta-endorphin (800 micrograms) and (/sup 14/C)methoxy-inulin (50 microCi) in 400 microliters of normal saline intrathecally. Serial samples of cerebrospinal fluid were drawn through a previously positioned indwelling spinal catheter and were assayed for concentrations of beta-endorphin (determined by radioimmunoassay) and inulin (determined by liquid scintillation counter). Spinal fluid concentrations of beta-endorphin and inulin peaked and declined in a parallel manner. The clearance ratio (calculated from the reciprocal of the ratio of the areas under the respective curves of elimination of the two species) remained remarkably similar from animal to animal, giving a mean value of 1.060 +/- 0.090 (SEM). This ratio, being near unity, suggests that beta-endorphin is eliminated from spinal fluid in a fashion similar to that of inulin, which is removed exclusively by bulk absorption.

  10. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M.

    2010-01-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings

  11. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M., E-mail: vm@szfki.hu [Hungarian Academy of Sciences, Research Institute for Solid State Physics and Optics, Department of Laser Applications, Konkoly Thege Miklós ut 29-33, 1121 Budapest, P.O. Box 49, 1525 Budapest (Hungary)

    2010-07-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings.

  12. Metallic implants and exposure to radiofrequency radiation

    International Nuclear Information System (INIS)

    Joyner, K.H.; Fleming, A.H.F.; MacFarlane, I.P.; Hocking, B.

    1988-01-01

    There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches 1 . The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in Telecom Australia, beginning with the general principles and then presenting a specific example discussion of a specific example

  13. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.; Buttner, Ulrich; Yi, Ying

    2016-01-01

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  14. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.

    2016-03-31

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  15. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  16. Hollow fiber: a biophotonic implant for live cells

    Science.gov (United States)

    Silvestre, Oscar F.; Holton, Mark D.; Summers, Huw D.; Smith, Paul J.; Errington, Rachel J.

    2009-02-01

    The technical objective of this study has been to design, build and validate biocompatible hollow fiber implants based on fluorescence with integrated biophotonics components to enable in fiber kinetic cell based assays. A human osteosarcoma in vitro cell model fiber system has been established with validation studies to determine in fiber cell growth, cell cycle analysis and organization in normal and drug treated conditions. The rationale for implant development have focused on developing benchmark concepts in standard monolayer tissue culture followed by the development of in vitro hollow fiber designs; encompassing imaging with and without integrated biophotonics. Furthermore the effect of introducing targetable biosensors into the encapsulated tumor implant such as quantum dots for informing new detection readouts and possible implant designs have been evaluated. A preliminary micro/macro imaging approach has been undertaken, that could provide a mean to track distinct morphological changes in cells growing in a 3D matrix within the fiber which affect the light scattering properties of the implant. Parallel engineering studies have showed the influence of the optical properties of the fiber polymer wall in all imaging modes. Taken all together, we show the basic foundation and the opportunities for multi-modal imaging within an in vitro implant format.

  17. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  18. [MR implant labelling and its use in clinical MRI practice].

    Science.gov (United States)

    Mühlenweg, M; Schaefers, G

    2015-08-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application.

  19. MR implant labelling and its use in clinical MRI practice

    International Nuclear Information System (INIS)

    Muehlenweg, M.; Schaefers, G.

    2015-01-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [de

  20. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  1. A novel pressed porous silicon-polycaprolactone composite as a dual-purpose implant for the delivery of cells and drugs to the eye.

    Science.gov (United States)

    Irani, Yazad D; Tian, Yuan; Wang, Mengjia; Klebe, Sonja; McInnes, Steven J; Voelcker, Nicolas H; Coffer, Jeffery L; Williams, Keryn A

    2015-10-01

    Dysfunction of corneal epithelial stem cells can result in painful and blinding disease of the ocular surface. In such cases, treatment may involve transfer of growth factor and normal adult stem cells to the ocular surface. Our purpose was to develop an implantable scaffold for the delivery of drugs and cells to the ocular surface. We examined the potential of novel composite biomaterials fabricated from electrospun polycaprolactone (PCL) fibres into which nanostructured porous silicon (pSi) microparticles of varying sizes (150-250 μm or <40 μm) had been pressed. The PCL fabric provided a flexible support for mammalian cells, whereas the embedded pSi provided a substantial surface area for efficient delivery of adsorbed drugs and growth factors. Measurements of tensile strength of these composites revealed that the pSi did not strongly influence the mechanical properties of the polymer microfiber component for the Si loadings evaluated. Human lens epithelial cells (SRA01/04) attached to the composite materials, and exhibited enhanced attachment and growth when the materials were coated with foetal bovine serum. To examine the ability of the materials to deliver a small-drug payload, pSi microparticles were loaded with fluorescein diacetate prior to cell attachment. After 6 hours (h), cells exhibited intracellular fluorescence, indicative of transfer of the fluorescein diacetate into viable cells and its subsequent enzymatic conversion to fluorescein. To investigate loading of large-molecule biologics, murine BALB/c 3T3 cells, responsive to epidermal growth factor, insulin and transferrin, were seeded on composite materials. The cells showed significantly more proliferation at 48 h when seeded on composites loaded with these biologics, than on unloaded composites. No cell proliferation was observed on PCL alone, indicating the biologics had loaded into the pSi microparticles. Drug release, measured by ELISA for insulin, indicated a burst followed by a slower

  2. Implant healing in experimental animal models of diabetes.

    Science.gov (United States)

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-05-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  3. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  4. [Fabrication of a new composite scaffold material for delivering rifampicin and its sustained drug release in rats].

    Science.gov (United States)

    Ma, Xue-Ming; Lin, Zhen; Zhang, Jia-Wei; Sang, Chao-Hui; Qu, Dong-Bin; Jiang, Jian-Ming

    2016-03-01

    To fabricate a new composite scaffold material as an implant for sustained delivery of rifampicin and evaluate its performance of sustained drug release and biocompatibility. The composite scaffold material was prepared by loading poly(lactic-co-glycolic) acid (PLGA) microspheres that encapsulated rifampicin in a biphasic calcium composite material with a negative surface charge. The in vitro drug release characteristics of the microspheres and the composite scaffold material were evaluated; the in vivo drug release profile of the composite scaffold material implanted in a rat muscle pouch was evaluated using high-performance liquid chromatography. The biochemical parameters of the serum and liver histopathologies of the rats receiving the transplantation were observed to assess the biocompatibility of the composite scaffold material. The encapsulation efficiency and drug loading efficiency of microspheres were (56.05±5.33)% and (29.80±2.88)%, respectively. The cumulative drug release rate of the microspheres in vitro was (94.19±5.4)% at 28 days, as compared with the rate of (82.23±6.28)% of composite scaffold material. The drug-loaded composite scaffold material showed a good performance of in vivo drug release in rats, and the local drug concentration still reached 16.18±0.35 µg/g at 28 days after implantation. Implantation of the composite scaffold material resulted in transient and reversible liver injury, which was fully reparred at 28 days after the implantation. The composite scaffold material possesses a good sustained drug release capacity and a good biocompatibility, and can serve as an alternative approach to conventional antituberculous chemotherapy.

  5. Analgesic and cardiopulmonary effects of intrathecally administered romifidine or romifidine and ketamine in goats (Capra hircus

    Directory of Open Access Journals (Sweden)

    H.P. Aithal

    2001-07-01

    Full Text Available The study was conducted to evaluate the effects of romifidine alone (50 µg/kg and a combination of romifidine (50 µg/kg and ketamine (2.5 mg/kg after intrathecal administration in goats. Ten adult goats of either sex weighing between 15 and 20 kg were randomly placed in 2 groups (groups I and II. The agents were administered at the lumbosacral subarachnoid space. Clinico-physiological parameters such as analgesia, motor incoordination, sedation, salivation, heart rate, respiratory rate, arterial pressure, central venous pressure and rectal temperature were studied. Other haematobiochemical parameters monitored were packed cell volume, haemoglobin, plasma proteins, glucose, urea and creatinine. The onset of analgesia was faster in group II (35.5 ±6.25 s compared to that of group I (5.2 ±0.54 min. Analgesia of the tail, perineum, hind limbs, flank and thorax was mild to moderate in group I, but complete analgesia of tail, perineum and hind limbs was recorded in group II. Motor incoordination was mild in group I and severe in group II. Significant reduction in heart rate (more pronounced in group I and respiratory rate (more pronounced in group II, and a significant increase in central venous pressure were recorded in both groups. Mean arterial pressure was reduced in both groups, but more markedly in group I. Sedation, electro-cardiogram, rectal temperature and haemato-biochemical parameters did not show significant differences between the 2 groups. The results of this study indicated a possible synergistic analgesic interaction between intrathecally administered romifidine and ketamine, without causing any marked systemic effects in goats.

  6. Comparative Study of Bio-implantable Acoustic Generator Architectures

    International Nuclear Information System (INIS)

    Christensen, D; Roundy, S

    2013-01-01

    This paper is a comparative study of the design spaces of two bio-implantable acoustically excited generator architectures: the thickness-stretch-mode circular piezoelectric plate and the bending-mode unimorph piezoelectric diaphragm. The generators are part of an acoustic power transfer system for implanted sensors and medical devices such as glucose monitors, metabolic monitors, drug delivery systems, etc. Our studies indicate that at small sizes the diaphragm architecture outperforms the plate architecture. This paper will present the results of simulation studies and initial experiments that explore the characteristics of the two architectures and compare their performance

  7. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  8. Ceramic drug-delivery devices.

    Science.gov (United States)

    Lasserre, A; Bajpai, P K

    1998-01-01

    A variety of ceramics and delivery systems have been used to deliver chemicals, biologicals, and drugs at various rates for desired periods of time from different sites of implantation. In vitro and in vivo studies have shown that ceramics can successfully be used as drug-delivery devices. Matrices, inserts, reservoirs, cements, and particles have been used to deliver a large variety of therapeutic agents such as antibiotics, anticancer drugs, anticoagulants, analgesics, growth factors, hormones, steroids, and vaccines. In this article, the advantages and disadvantages of conventional drug-delivery systems and the different approaches used to deliver chemical and biological agents by means of ceramic systems will be reviewed.

  9. A Microfluidic Ion Pump for In Vivo Drug Delivery

    KAUST Repository

    Uguz, Ilke; Proctor, Christopher M.; Curto, Vincenzo F.; Pappa, Anna-Maria; Donahue, Mary J.; Ferro, Magali; Owens, Ró isí n M.; Khodagholy, Dion; Inal, Sahika; Malliaras, George G.

    2017-01-01

    Implantable devices offer an alternative to systemic delivery of drugs for the treatment of neurological disorders. A microfluidic ion pump (µFIP), capable of delivering a drug without the solvent through electrophoresis, is developed. The device

  10. Magnetic Beads Enhance Adhesion of NIH 3T3 Fibroblasts: A Proof-of-Principle In Vitro Study for Implant-Mediated Long-Term Drug Delivery to the Inner Ear.

    Science.gov (United States)

    Aliuos, Pooyan; Schulze, Jennifer; Schomaker, Markus; Reuter, Günter; Stolle, Stefan R O; Werner, Darja; Ripken, Tammo; Lenarz, Thomas; Warnecke, Athanasia

    2016-01-01

    Long-term drug delivery to the inner ear may be achieved by functionalizing cochlear implant (CI) electrodes with cells providing neuroprotective factors. However, effective strategies in order to coat implant surfaces with cells need to be developed. Our vision is to make benefit of electromagnetic field attracting forces generated by CI electrodes to bind BDNF-secreting cells that are labelled with magnetic beads (MB) onto the electrode surfaces. Thus, the effect of MB-labelling on cell viability and BDNF production were investigated. Murine NIH 3T3 fibroblasts-genetically modified to produce BDNF-were labelled with MB. Atomic force and bright field microscopy illustrated the internalization of MB by fibroblasts after 24 h of cultivation. Labelling cells with MB did not expose cytotoxic effects on fibroblasts and allowed adhesion on magnetic surfaces with sufficient BDNF release. Our data demonstrate a novel approach for mediating enhanced long-term adhesion of BDNF-secreting fibroblasts on model electrode surfaces for cell-based drug delivery applications in vitro and in vivo. This therapeutic strategy, once transferred to cells suitable for clinical application, may allow the biological modifications of CI surfaces with cells releasing neurotrophic or other factors of interest.

  11. Magnetic Beads Enhance Adhesion of NIH 3T3 Fibroblasts: A Proof-of-Principle In Vitro Study for Implant-Mediated Long-Term Drug Delivery to the Inner Ear.

    Directory of Open Access Journals (Sweden)

    Pooyan Aliuos

    Full Text Available Long-term drug delivery to the inner ear may be achieved by functionalizing cochlear implant (CI electrodes with cells providing neuroprotective factors. However, effective strategies in order to coat implant surfaces with cells need to be developed. Our vision is to make benefit of electromagnetic field attracting forces generated by CI electrodes to bind BDNF-secreting cells that are labelled with magnetic beads (MB onto the electrode surfaces. Thus, the effect of MB-labelling on cell viability and BDNF production were investigated.Murine NIH 3T3 fibroblasts-genetically modified to produce BDNF-were labelled with MB.Atomic force and bright field microscopy illustrated the internalization of MB by fibroblasts after 24 h of cultivation. Labelling cells with MB did not expose cytotoxic effects on fibroblasts and allowed adhesion on magnetic surfaces with sufficient BDNF release.Our data demonstrate a novel approach for mediating enhanced long-term adhesion of BDNF-secreting fibroblasts on model electrode surfaces for cell-based drug delivery applications in vitro and in vivo. This therapeutic strategy, once transferred to cells suitable for clinical application, may allow the biological modifications of CI surfaces with cells releasing neurotrophic or other factors of interest.

  12. MRI information for commonly used otologic implants: review and update.

    Science.gov (United States)

    Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G

    2014-04-01

    To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.

  13. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Preparation, characterization, and in vitro cytotoxicity evaluation of a novel anti-tuberculosis reconstruction implant.

    Directory of Open Access Journals (Sweden)

    JunFeng Dong

    Full Text Available Reconstruction materials currently used in clinical for osteoarticular tuberculosis (TB are unsatisfactory due to a variety of reasons. Rifampicin (RFP is a well-known and highly effective first-line anti-tuberculosis (anti-TB drug. Poly-DL-lactide (PDLLA and nano-hydroxyapatite (nHA are two promising materials that have been used both for orthopedic reconstruction and as carriers for drug release. In this study we report the development of a novel anti-TB implant for osteoarticular TB reconstruction using a combination of RFP, PDLLA and nHA.RFP, PDLLA and nHA were used as starting materials to produce a novel anti-TB activity implant by the solvent evaporation method. After manufacture, the implant was characterized and its biodegradation and drug release profile were tested. The in vitro cytotoxicity of the implant was also evaluated in pre-osteoblast MC3T3-E1 cells using multiple methodologies.A RFP/PDLLA/nHA composite was successfully synthesized using the solvent evaporation method. The composite has a loose and porous structure with evenly distributed pores. The production process was steady and no chemical reaction occurred as proved by Fourier Transform Infrared Spectroscopy (FTIR and X-Ray Diffraction (XRD. Meanwhile, the composite blocks degraded and released drug for at least 12 weeks. Evaluation of in vitro cytotoxicity in MC3T3-E1 cells verified that the synthesized composite blocks did not affect cell growth and proliferation.It is feasible to manufacture a novel bioactive anti-TB RFP/PDLLA/nHA composite by the solvent evaporation method. The composite blocks showed appropriate properties such as degradation, drug release and biosafety to MC3T3-E1 cells. In conclusion, the novel composite blocks may have great potential for clinical applications in repairing bone defects caused by osteoarticular TB.

  15. Multicompartment Drug Release System for Dynamic Modulation of Tissue Responses.

    Science.gov (United States)

    Morris, Aaron H; Mahal, Rajwant S; Udell, Jillian; Wu, Michelle; Kyriakides, Themis R

    2017-10-01

    Pharmacological modulation of responses to injury is complicated by the need to deliver multiple drugs with spatiotemporal resolution. Here, a novel controlled delivery system containing three separate compartments with each releasing its contents over different timescales is fabricated. Core-shell electrospun fibers create two of the compartments in the system, while electrosprayed spheres create the third. Utility is demonstrated by targeting the foreign body response to implants because it is a dynamic process resulting in implant failure. Sequential delivery of a drug targeting nuclear factor-κB (NF-κB) and an antifibrotic is characterized in in vitro experiments. Specifically, macrophage fusion and p65 nuclear translocation in the presence of releasate or with macrophages cultured on the surfaces of the constructs are evaluated. In addition, releasate from pirfenidone scaffolds is shown to reduce transforming growth factor-β (TGF-β)-induced pSMAD3 nuclear localization in fibroblasts. In vivo, drug eluting constructs successfully mitigate macrophage fusion at one week and fibrotic encapsulation in a dose-dependent manner at four weeks, demonstrating effective release of both drugs over different timescales. Future studies can employ this system to improve and prolong implant lifetimes, or load it with other drugs to modulate other dynamic processes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Three-Dimensional Printing of Drug-Eluting Implants

    DEFF Research Database (Denmark)

    Water, Jorrit Jeroen; Bohr, Adam; Bøtker, Johan Peter

    2015-01-01

    The aim of the present work was to investigate the potential of three-dimensional (3D) printing as a manufacturing method for products intended for personalized treatments by exploring the production of novel polylactide-based feedstock materials for 3D printing purposes. Nitrofurantoin (NF......) and hydroxyapatite (HA) were successfully mixed and extruded with up to 30% drug load with and without addition of 5% HA in polylactide strands, which were subsequently 3D-printed into model disc geometries (10 × 2 mm). X-ray powder diffraction analysis showed that NF maintained its anhydrate solid form during...... of custom-made, drug-loaded feedstock materials for 3D printing of pharmaceutical products for controlled release....

  17. Synergistic effects of bisphosphonate and calcium phosphate nanoparticles on peri-implant bone responses in osteoporotic rats

    NARCIS (Netherlands)

    Alghamdi, H.S.A.; Bosco, R.; Both, S.K.; Iafisco, M.; Leeuwenburgh, S.C.G.; Jansen, J.A.; Beucken, J.J.J.P van den

    2014-01-01

    The prevalence of osteoporosis will increase within the next decades due to the aging world population, which can affect the bone healing response to dental and orthopedic implants. Consequently, local drug targeting of peri-implant bone has been proposed as a strategy for the enhancement of

  18. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  19. Magnesium alloys as bioresorbable biomaterials with drug delivery capabilities

    OpenAIRE

    JESSICA ANNE LYNDON

    2017-01-01

    Magnesium is one of the most active metals and is prone to corrosion. In construction, automotive and aerospace industries this is seen as a detrimental property. However, coupling corrosion with magnesiums’s favourable strength, weight and density a new type of temporary implants are being developed to rehabilitate damaged bone, without the need for surgery to remove the implant. Taking this concept further, this thesis uses the corrosion mechanism to deliver drugs from the implant as it is ...

  20. Five-year follow-up data from the U.S. clinical trial for Sientra's U.S. Food and Drug Administration-approved Silimed® brand round and shaped implants with high-strength silicone gel.

    Science.gov (United States)

    Stevens, W Grant; Harrington, Jennifer; Alizadeh, Kaveh; Berger, Lewis; Broadway, David; Hester, T Roderick; Kress, Donald; dʼIncelli, Rosalyn; Kuhne, JoAnn; Beckstrand, Maggi

    2012-11-01

    In March of 2012, the U.S. Food and Drug Administration approved Sientra's application for premarket approval for its Silimed brand silicone gel implants, based on data from the largest silicone gel breast implant study to date. This was the first approval for shaped silicone gel breast implants. This article presents the results of Sientra's study through 5 years. Sientra's study is an ongoing, 10-year, open-label, prospective, multicenter clinical study designed to assess the safety and effectiveness of Sientra's implants in patients undergoing augmentation and reconstruction. A total of 1788 subjects were implanted with 3506 implants, including 1116 primary augmentation, 363 revision-augmentation, 225 primary reconstruction, and 84 revision-reconstruction subjects. Physical evaluations and complications were recorded at each visit. Effectiveness was measured by postimplantation bra cup size and assessment of subject satisfaction and quality of life. Of the 1788 subjects, 571 underwent magnetic resonance imaging to assess silent rupture. Safety endpoints were analyzed using the Kaplan-Meier method. Across all cohorts, the risk of rupture was 1.8 percent (95 percent CI, 1.2 to 2.6 percent), the risk of capsular contracture (Baker grade III/IV) was 9.0 percent (95 percent CI, 7.6 to 10.6 percent), and the risk of reoperation was 23.8 percent (95 percent CI, 21.8 to 26.0 percent). Over 99 percent of surgeons reported satisfaction with the postoperative results, and subject satisfaction remained high 5 years after implantation. The 5-year results of Sientra's study continue to provide a comprehensive safety and effectiveness profile of Sientra's portfolio of Silimed brand shaped and round implants. Therapeutic, IV.

  1. Nanocarrier mediated retinal drug delivery: overcoming ocular barriers to treat posterior eye diseases.

    Science.gov (United States)

    Bisht, Rohit; Mandal, Abhirup; Jaiswal, Jagdish K; Rupenthal, Ilva D

    2018-03-01

    Effective drug delivery to the retina still remains a challenge due to ocular elimination mechanisms and complex barriers that selectively limit the entry of drugs into the eye. To overcome these barriers, frequent intravitreal injections are currently used to achieve high drug concentrations in vitreous and retina. However, these repetitive injections may result in several side effects. Recent advancements in the field of nanoparticle-based drug delivery could overcome some of these unmet needs and various preclinical studies conducted to date have demonstrated promising results of nanotherapies in the treatment of retinal diseases. Compared to the majority of commercially available ocular implants, the biodegradable nature of most nanoparticles (NPs) avoids the need for surgical implantation and removal after the release of the payload. In addition, the sustained drug release from NPs over an extended period of time reduces the need for frequent intravitreal injections and the risk of associated side effects. The nanometer size and highly modifiable surface properties make NPs excellent candidates for targeted ocular drug delivery. Studies have shown that nanocarriers enhance the intravitreal half-life and thus bioavailability of a number of drugs including proteins and peptides. In addition, they have shown promising results in delivering genetic material to the retinal tissues by protecting it from possible intravitreal degradation. This review covers the various challenges associated with drug delivery to the posterior segment of the eye, particularly the retina, and highlights the application of nanocarriers to overcome these challenges in context with recent advances in preclinical studies. WIREs Nanomed Nanobiotechnol 2018, 10:e1473. doi: 10.1002/wnan.1473 This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Implantable Materials and Surgical Technologies > Nanomaterials and Implants. © 2017 Wiley Periodicals

  2. Intracranial drug-delivery scaffolds: Biocompatibility evaluation of sucrose acetate isobutyrate gels

    International Nuclear Information System (INIS)

    Lee, James; Jallo, George I.; Penno, Margaret B.; Gabrielson, Kathleen L.; Young, G. David; Johnson, Randolph M.; Gillis, Edward M.; Rampersaud, Charles; Carson, Benjamin S.; Guarnieri, Michael

    2006-01-01

    Introduction: Sucrose acetate isobutyrate (SAIB) is a water insoluble, biodegradable gel used for controlled-release oral and subcutaneous drug delivery. We investigated SAIB compatibility in the rat central nervous system (CNS) by implanting solutions of SAIB in adult and in neonatal brains. Methods: 10-15 μL solutions of SAIB gels in 0-30% ethanol were injected into the cerebral cortex of adult Fischer 344 rats. Control animals were implanted with a 10 mg biodegradable poly anhydride copolymer of poly [bis (p-carboxyphenoxy) propane] anhydride and sebacic acid (PCPP:SA). Adult rats were evaluated for signs of pain and distress, including changes in posture, facial signs, and grooming behavior. 1-2 μL solutions of SAIB gels in 15% ethanol were injected into brains of 12-24 h-old rats. Neonatal rats were evaluated for survival. Adult and neonatal brains were examined by histopathology 3-48 days after implant. Results: Gel implants produced elliptical compression of cortical tissue, cell loss, and inflammation. Cell loss appeared to be confined to the implantation wound and associated neuronal fields. In adult rats, neurophil compression, inflammation, and cell loss appeared similar with the 10-mg PCPP:SA implants and the 10-mg SAIB implants. There was no clinical evidence of pain or distress from SAIB implants. 1-2 μL implants of SAIB-15% ethanol had no effect on survival of neonatal animals. Conclusion: Brain implants of SAIB induce a mild to moderate inflammatory response and associated neuronal cell damage. The implants appeared to be biocompatible in adult and neonatal animals. These results suggest that further studies of SAIB as an injectable drug-delivery scaffold for CNS therapeutic agents are warranted

  3. Association between change in normal appearing white matter metabolites and intrathecal inflammation in natalizumab-treated multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Johan Mellergård

    Full Text Available BACKGROUND: Multiple sclerosis (MS is associated not only with focal inflammatory lesions but also diffuse pathology in the central nervous system (CNS. Since there is no firm association between the amount of focal inflammatory lesions and disease severity, diffuse pathology in normal appearing white matter (NAWM may be crucial for disease progression. Immunomodulating treatments for MS reduce the number of focal lesions, but possible effects on diffuse white matter pathology are less studied. Furthermore, it is not known whether intrathecal levels of inflammatory or neurodegenerative markers are associated with development of pathology in NAWM. METHODS: Quantitative proton magnetic resonance spectroscopy ((1H-MRS was used to investigate NAWM in 27 patients with relapsing MS before and after one year of treatment with natalizumab as well as NAWM in 20 healthy controls at baseline. Changes in (1H-MRS metabolite concentrations during treatment were also correlated with a panel of intrathecal markers of inflammation and neurodegeneration in 24 of these 27 patients. RESULTS: The group levels of (1H-MRS metabolite concentrations were unchanged pre- to posttreatment, but a pattern of high magnitude correlation coefficients (r = 0.43-0.67, p<0.0005-0.03 were found between changes in individual metabolite concentrations (total creatine and total choline and levels of pro-inflammatory markers (IL-1β and CXCL8. CONCLUSIONS: Despite a clinical improvement and a global decrease in levels of inflammatory markers in cerebrospinal fluid during treatment, high levels of pro-inflammatory CXCL8 and IL-1β were associated with an increase in (1H-MRS metabolites indicative of continued gliosis development and membrane turnover in NAWM.

  4. Relation of intrathecal oligoclonal band production to inflammatory mediator and immunotherapy response in 208 children with OMS.

    Science.gov (United States)

    Pranzatelli, Michael R; McGee, Nathan R; Tate, Elizabeth D

    2018-04-12

    In 208 children with opsoclonus-myoclonus syndrome (OMS), CSF IgG oligoclonal bands (OCB) and 22 immunomarkers in CSF and 21 in serum/blood were measured. In 36 untreated OMS, 58% were OCB(+), whereas 55% of treated OMS were OCB(-). OCB positivity or negativity did not alter concentrations or frequencies of immunomarkers. The phenotypes of OCB(+) and OCB(-) patients were not distinctive. CSF B cells were expanded in untreated OMS regardless of OCB positivity. These data reveal a much higher frequency of OCB positivity in untreated OMS than previously realized and a disconnect between intrathecal OCB and inflammatory mediator production. Copyright © 2018. Published by Elsevier B.V.

  5. Towards soft robotic devices for site-specific drug delivery.

    Science.gov (United States)

    Alici, Gursel

    2015-01-01

    Considerable research efforts have recently been dedicated to the establishment of various drug delivery systems (DDS) that are mechanical/physical, chemical and biological/molecular DDS. In this paper, we report on the recent advances in site-specific drug delivery (site-specific, controlled, targeted or smart drug delivery are terms used interchangeably in the literature, to mean to transport a drug or a therapeutic agent to a desired location within the body and release it as desired with negligibly small toxicity and side effect compared to classical drug administration means such as peroral, parenteral, transmucosal, topical and inhalation) based on mechanical/physical systems consisting of implantable and robotic drug delivery systems. While we specifically focus on the robotic or autonomous DDS, which can be reprogrammable and provide multiple doses of a drug at a required time and rate, we briefly cover the implanted DDS, which are well-developed relative to the robotic DDS, to highlight the design and performance requirements, and investigate issues associated with the robotic DDS. Critical research issues associated with both DDSs are presented to describe the research challenges ahead of us in order to establish soft robotic devices for clinical and biomedical applications.

  6. Novel polymeric bioerodable microparticles for prolonged-release intrathecal delivery of analgesic agents for relief of intractable cancer-related pain.

    Science.gov (United States)

    Han, Felicity Y; Thurecht, Kristofer J; Lam, Ai-Leen; Whittaker, Andrew K; Smith, Maree T

    2015-07-01

    Intractable cancer-related pain complicated by a neuropathic component due to nerve impingement is poorly alleviated even by escalating doses of a strong opioid analgesic. To address this unmet medical need, we developed sustained-release, bioerodable, hydromorphone (potent strong opioid)- and ketamine (analgesic adjuvant)-loaded microparticles for intrathecal (i.t.) coadministration. Drug-loaded poly(lactic-co-glycolic acid) (PLGA) microparticles were prepared using a water-in-oil-in-water method with evaporation. Encapsulation efficiency of hydromorphone and ketamine in PLGA (50:50) microparticles was 26% and 56%, respectively. Microparticles had the desired size range (20-60 μm) and in vitro release was prolonged at ≥28 days. Microparticles were stable for ≥6 months when stored refrigerated protected from light in a desiccator. Desirably, i.t. injected fluorescent dye-labeled PLGA microparticles in rats remained in the lumbar region for ≥7 days. In a rat model of neuropathic pain, i.t. coinjection of hydromorphone- and ketamine-loaded microparticles (each 1 mg) produced analgesia for 8 h only. Possible explanations include inadequate release of ketamine and/or hydromorphone into the spinal fluid, and/or insufficient ketamine loading to prevent development of analgesic tolerance to the released hydromorphone. As sub-analgesic doses of i.t. ketamine at 24-48 h intervals restored analgesia on each occasion, insufficient ketamine loading appears problematic. We will investigate these issues in future work. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  7. Potential applications of biphosphonates in dental surgical implants.

    Science.gov (United States)

    Berardi, D; Carlesi, T; Rossi, F; Calderini, M; Volpi, R; Perfetti, G

    2007-01-01

    Biphosphonates are largely used for their unquestionable properties of inhibiting bone resorption by osteoclasts in the treatment of various osteometabolic illnesses such as osteoporosis, multiple myeloma, tumors which metastasize to the bone and malignant hypercalcemia. In this literature review the physico-chemical properties, biologic activities and the mechanisms of action of biphosphonates are described. The use of these drugs is discussed, analyzing the quantity of results which have emerged through in vitro and in vivo experiments on animal models. In this study the efficiency of these drugs is demonstrated in contrasting the osteolitic processes of the alveolar bone, in promoting the neoformation and in bettering the quality of bone implants. However, it is important to draw attention to a worrying correlation which has emerged during the last 3-4 years, between osteonecrosis of the jaw (ONJ) and the systemic administration of aminobiphosphonates. This collateral effect did not emerge following the use of non-aminobiphosphonates. The aim of this review is to identify the guidelines for the use of biphosphonates in oral implant surgery.

  8. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  9. The Comparison of Intrathecal Morphine and IV Morphine PCA on Pain Control, Patient Satisfaction, Morphine Consumption, and Adverse Effects in Patients Undergoing Reduction Mammoplasty.

    Science.gov (United States)

    Karamese, Mehtap; Akdağ, Osman; Kara, İnci; Yıldıran, Gokce Unal; Tosun, Zekeriya

    2015-01-01

    Following breast reduction procedures, the level of postoperative pain can be severe, and sufficient pain control influences a patient's physiological, immunological, and psychological status. The aim of this study was to examine the use of intrathecal morphine (ITM) in breast reduction surgery with patient-controlled analgesia (PCA). Sixty-two female patients who underwent breast reductions with the same technique participated in this study. The study group (ITM + PCA) included 32 patients; a single shot (0.2 mg) of ITM and intravenous morphine with PCA were administered. In the control group, morphine PCA alone was intravenously administered to 30 patients. Comparisons between the groups of cumulative morphine consumption, visual analog scale scores, and patient satisfaction scores, which were the primary outcome measures, and adverse effects, which were the secondary outcome measures, were conducted. The patients in the 2 groups had similar degrees of pain and satisfaction scores. The study group had lower cumulative morphine consumption (P = .001) than the PCA-only control group; there was no statistically significant difference in adverse effects between the 2 groups. Intrathecal morphine may effectively control pain with lower total morphine consumption following breast reduction surgery.

  10. A Randomized Placebo-Controlled Trial of Oral Ramosetron for Prevention of Post Operative Nausea and Vomiting after Intrathecal Morphine in Patients Undergoing Gynecological Surgery.

    Science.gov (United States)

    Wangnamthip, Suratsawadee; Chinachoti, Thitima; Amornyotin, Somchai; Wongtangman, Karuna; Sukantarat, Numphung; Noitasaeng, Papiroon

    2016-05-01

    The incidence of postoperative nausea and vomiting (PONV) after intrathecal morphine is high. Ramosetron is a 5-HT₃ antagonist that has been shown to reduce PONV in general anesthesia. The objective of this study was to evaluate the efficacy of Ramosetron in preventing PONV MATERIAL AND METHOD: 165 patients undergoing elective gynecological surgery under spinal anesthesia were randomly allocated to two groups: the Ramosetron group (0.1 mg orally, n = 82), and the placebo group (oral corn starch, n = 83). The incidence of PONV severity of nausea and use of rescue antiemetic during the first 24 hour after surgery were evaluated. The incidence of PONV was significantly lower in the Ramosetron group compared with the placebo group (24.4% vs. 44.6%, number needed to treat (NNT) = 5.0). The severity of nausea was significantly lower in the Ramosetron group compared with the placebo group (20.7% vs. 39.8%, NNT = 6.0) in the 24 hour period. Oral Ramosetron 0.1 mg was more effective than placebo in PONV prevention and reduced the incidence of moderate to severe nausea after intrathecal morphine in the first 24 hour after gynecological surgery.

  11. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  12. Dose distribution to spinal structures from intrathecally administered yttrium-90

    Science.gov (United States)

    Mardirossian, George; Hall, Michael; Montebello, Joseph; Stevens, Patrick

    2006-01-01

    Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of 131I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as 90Y replaces 131I. The purpose of this study is to compare and quantitatively evaluate the dose distribution from 90Y to the CSF space and its surrounding spinal structures to 131I. A 3D digital phantom of a section of the T-spine was constructed from the visible human project series of images which included the spinal cord, central canal, subarachnoid space, pia mater, arachnoid, dura mater, vertebral bone marrow and intervertebral disc. Monte Carlo N-particle (MCNP4C) was used to model the 90Y and 131I radiation distribution. Images of the CSF compartment were convolved with the radiation distribution to determine the dose within the subarachnoid space and surrounding tissues. 90Y appears to be a suitable radionuclide in the treatment of central nervous system (CNS) malignancies when attached to mAb's and the dose distribution would be confined largely within the vertebral foramen. This choice may offer favourable dose improvement to the subarachnoid and surface of spinal cord over 131I in such an application.

  13. Implant-assisted magnetic drug targeting in permeable microvessels: Comparison of two-fluid statistical transport model with experiment

    Energy Technology Data Exchange (ETDEWEB)

    ChiBin, Zhang; XiaoHui, Lin, E-mail: lxh60@seu.edu.cn; ZhaoMin, Wang; ChangBao, Wang

    2017-03-15

    In experiments and theoretical analyses, this study examines the capture efficiency (CE) of magnetic drug carrier particles (MDCPs) for implant-assisted magnetic drug targeting (IA-MDT) in microvessels. It also proposes a three-dimensional statistical transport model of MDCPs for IA-MDT in permeable microvessels, which describes blood flow by the two-fluid (Casson and Newtonian) model. The model accounts for the permeable effect of the microvessel wall and the coupling effect between the blood flow and tissue fluid flow. The MDCPs move randomly through the microvessel, and their transport state is described by the Boltzmann equation. The regulated changes and factors affecting the CE of the MDCPs in the assisted magnetic targeting were obtained by solving the theoretical model and by experimental testing. The CE was negatively correlated with the blood flow velocity, and positively correlated with the external magnetic field intensity and microvessel permeability. The predicted CEs of the MDCPs were consistent with the experimental results. Additionally, under the same external magnetic field, the predicted CE was 5–8% higher in the IA-MDT model than in the model ignoring the permeability effect of the microvessel wall. - Highlights: • A model of MDCPs for IA-MDT in permeable microvessels was established. • An experimental device was established, the CE of MDCPs was measured. • The predicted CE of MDCPs was 5–8% higher in the IA-MDT model.

  14. Influence of Statins locally applied from orthopedic implants on osseous integration

    Directory of Open Access Journals (Sweden)

    Pauly Stephan

    2012-10-01

    Full Text Available Abstract Background Simvastatin increases the expression of bone morphogenetic protein 2 (BMP-2 in osteoblasts, therefore it is important to investigate the influence of statins on bone formation, fracture healing and implant integration. The aim of the present study was to investigate the effect of Simvastatin, locally applied from intramedullary coated and bioactive implants, on bone integration using biomechanical and histomorphometrical analyses. Methods Eighty rats received retrograde nailing of the femur with titanium implants: uncoated vs. polymer-only (poly(D,L-lactide vs. polymer plus drug coated (either Simvastatin low- or high dosed; “SIM low/ high”. Femurs were harvested after 56 days for radiographic and histomorphometric or biomechanical analysis (push-out. Results Radiographic analysis revealed no pathological findings for animals of the control and SIM low dose group. However, n=2/10 animals of the SIM high group showed osteolysis next to the implant without evidence of bacterial infection determined by microbiological analysis. Biomechanical results showed a significant decrease in fixation strength for SIM high coated implants vs. the control groups (uncoated and PDLLA. Histomorphometry revealed a significantly reduced total as well as direct bone/implant contact for SIM high- implants vs. controls (uncoated and PDLLA-groups. Total contact was reduced for SIM low vs. uncoated controls. Significantly reduced new bone formation was measured around SIM high coated implants vs. both control groups. Conclusions This animal study suggests impaired implant integration with local application of Simvastatin from intramedullary titanium implants after 8 weeks when compared to uncoated or carrier-only coated controls.

  15. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  16. New developments in managing opioid addiction: impact of a subdermal buprenorphine implant

    Directory of Open Access Journals (Sweden)

    Itzoe M

    2017-05-01

    Full Text Available MariaLisa Itzoe, Michael Guarnieri Department of Neurological Surgery, Johns Hopkins School of Medicine, Baltimore, MD, USA Abstract: Opioid addiction to prescription and illicit drugs is a serious and growing problem. In the US alone, >2.4 million people suffer from opioid use disorder. Government and pharmaceutical agencies have begun to address this crisis with recently released and revised task forces and medication-assisted therapies (MAT. For decades, oral or intravenous (IV MATs have helped patients in their recovery by administration of opioid agonists (methadone, buprenorphine, oxycodone, antagonists (naltrexone, naloxone, and combinations of the two (buprenorphine/naloxone. While shown to be successful, particularly when combined with psychological counseling, oral and IV forms of treatment come with constraints and challenges. Patients can become addicted to the agonists themselves, and there is increased risk for diversion, abuse, or missed dosages. Consequently, long-acting implants have begun to be developed as a potentially preferable method of agonist delivery. To date, the newest implant approved by the US Food and Drug Administration (May 2016 is Probuphine®, which delivers steady-state levels of buprenorphine over the course of 6 months. Numerous studies have demonstrated its efficacy and safety. Yet, implants come with their own risks such as surgical site irritation, possible movement, and protrusion of implant out of skin. This review introduces the opioid abuse epidemic, examines existing medications used for therapy, and highlights Probuphine as a new treatment option. Costs associated with MATs are also discussed. Keywords: addiction, opioids, medication-assisted therapy, long-acting implant, buprenorphine, Probuphine®

  17. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  18. Vancomycin–chitosan composite deposited on post porous hydroxyapatite coated Ti6Al4V implant for drug controlled release

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chi-Chuan [Department of Materials Science and Engineering, National Chung Hsing, University 250, Kuo-Kuang Road, Taichung 40227, Taiwan (China); Lin, Chien-Chung [Department of Materials Science and Engineering, National Chung Hsing, University 250, Kuo-Kuang Road, Taichung 40227, Taiwan (China); Department of Orthopaedic Surgery, Taichung Armed Force General Hospital, 348, Sec. 2, Jhongshan Road, Taiping City, Taichung 411, Taiwan (China); Liao, Jiunn-Wang [Graduate Institute of Veterinary Pathobiology, National Chung Hsing, University 250, Kuo-Kuang Road, Taichung 40227, Taiwan (China); Yen, Shiow-Kang, E-mail: skyen@dragon.nchu.edu.tw [Department of Materials Science and Engineering, National Chung Hsing, University 250, Kuo-Kuang Road, Taichung 40227, Taiwan (China)

    2013-05-01

    Through the hydrogen bonds and the deprotonation, the vancomycin–chitosan composite has been originally deposited on Ti4Al4V by electrochemical technology. However, the rapid destruction of the hydrogen bonding between them by polar water molecules during immersion tests revealed 80% drug burst in a few hours. In this study, the post porous hydroxyapatite (HA) coated Ti4Al4V is prepared for the subsequent electrolytic deposition of vancomycin–chitosan composite to control the drug release. As expected, the initial burst is reduced to 55%, followed by a steady release about 20% from day 1 to day 5 and a slower release of the retained 25% after day 6, resulting in bacterial inhibition zone diameter of 30 mm which can last for more than a month in antibacterial tests, compared with the coated specimen without HA gradually loosing inhibition zone after 21 days. Besides, the cell culture indicates that the vancomycin–chitosan/HA composite coated has enhanced the proliferation, the differentiation and the mineralization of the osteoblast-like cell. In general, it is helpful for the osteointegration on permanent implants. Consistently, it effectively provides the prophylaxis and therapy of osteomyelitis according to the results of the rabbit infection animal model. - Highlights: ► The releasing curve of the vancomycin–chitosan/HA composite revealed three periods. ► The drug release sustained one month due to the effect of post porous HA coating. ► The composite coating could treat the osteomyelitis in the rabbit infection model.

  19. New developments in managing opioid addiction: impact of a subdermal buprenorphine implant.

    Science.gov (United States)

    Itzoe, MariaLisa; Guarnieri, Michael

    2017-01-01

    Opioid addiction to prescription and illicit drugs is a serious and growing problem. In the US alone, >2.4 million people suffer from opioid use disorder. Government and pharmaceutical agencies have begun to address this crisis with recently released and revised task forces and medication-assisted therapies (MAT). For decades, oral or intravenous (IV) MATs have helped patients in their recovery by administration of opioid agonists (methadone, buprenorphine, oxycodone), antagonists (naltrexone, naloxone), and combinations of the two (buprenorphine/naloxone). While shown to be successful, particularly when combined with psychological counseling, oral and IV forms of treatment come with constraints and challenges. Patients can become addicted to the agonists themselves, and there is increased risk for diversion, abuse, or missed dosages. Consequently, long-acting implants have begun to be developed as a potentially preferable method of agonist delivery. To date, the newest implant approved by the US Food and Drug Administration (May 2016) is Probuphine ® , which delivers steady-state levels of buprenorphine over the course of 6 months. Numerous studies have demonstrated its efficacy and safety. Yet, implants come with their own risks such as surgical site irritation, possible movement, and protrusion of implant out of skin. This review introduces the opioid abuse epidemic, examines existing medications used for therapy, and highlights Probuphine as a new treatment option. Costs associated with MATs are also discussed.

  20. A preliminary randomized clinical trial comparing diode laser and scalpel periosteal incision during implant surgery: impact on postoperative morbidity and implant survival.

    Science.gov (United States)

    Shahnaz, Aysan; Jamali, Raika; Mohammadi, Farnush; Khorsand, Afshin; Moslemi, Neda; Fekrazad, Reza

    2018-01-01

    The aim of this preliminary randomized clinical trial was to compare: (1) post-operative morbidity after application of laser or scalpel incision for flap advancement during implant surgery and bone grafting and (2) implant survival rate following flap advancement with laser or scalpel incision after 6 months of loading. Eighteen patients who were scheduled for dental implant placement and simultaneous bone grafting were randomly assigned to test or control groups. Diode laser (810 nm, 2 W, pulse interval 200 μs; pulse length 100 μs, 400-μm initiated fiber tip), or scalpel (control) was used to sever the periosteum to create a tension-free flap. Visual analogue scale (VAS) pain score, rate of nonsteroid anti-inflammatory drug (NSAID) consumption, intensity of swelling, and ecchymosis were measured for the six postsurgical days. Six months after loading, implant survival was assessed. VAS pain score (during the first four postoperative days), rate of NSAID consumption (during the first three postoperative days), and intensity of swelling (during the first five postoperative days) were significantly lower in the test group compared to the control group (All P values laser for performing periosteal releasing incision reduced the incidence and severity of postoperative morbidity of the patients undergone implant surgery in conjunction with bone augmentation procedure. We did not find any detrimental effect of laser incision on the implant survival within 6 months of loading.

  1. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  2. Comparison of central nervous system prophylaxis with cranial radiation and intrathecal methotrexate versus intrathecal methotrexate alone in acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Muriel, F.S.; Svarch, E.; Pavlovsky, S.

    1983-01-01

    In acute lymphoblastic leukemia, central nervous system prophylaxis with irradiation plus intrathecal methotrexate (i.t. MTX) reduces the incidence of CNS relapse to 7%-15%. However, increased evidence of CNS delayed toxicity was recognized mainly in children as CT scan abnormalities and neuropsychologic alterations. Two questions were analyzed: (1) Will further doses of i.t. methotraxate and dexamethasone (i.t. MTX-DMT) decrease the incidence of CNS relapse. (2) Is i.t. MTX-DMT given during induction and maintenance as effective as cranium irradiation plus i.t. MTX-DMT. Incidence of primary CNS relapse in i.t. MTX-DMT-treated patients with a WBC count 50,000, it was 16% in the treated group and 19% in the control group. These patients were compared with patients which had received 3 doses of i.t. MTX-DMT alone during induction, 3 doses weekly during the first month of remission, and quarterly thereafter. The incidence of leukemia at 60 mo in patients with a WBC count 50,000 at 48 mo was 28% and 42% in the irradiated and nonirradiated group respectively. Complete remission remained at 15% and 16% respectively of patients disease-free at 48 mo. We conclude that (A) after cranial irradiation plus i.t. MTX-DMT X 5, the use of additional doses of i.t. MTX-DMT is not of further benefit in preventing CNS relapse; (B) use of i.t. MTX-DMT alone compares with cranial irradiation plus i.t. MTX-DMT in incidence of CNS relapse; and (C) relapse-free survival and survival in patients with a WBC count < 50.000 were significantly longer in those without cranial irradiation

  3. A classification of growth friendly spine implants.

    Science.gov (United States)

    Skaggs, David L; Akbarnia, Behrooz A; Flynn, John M; Myung, Karen S; Sponseller, Paul D; Vitale, Michael G

    2014-01-01

    Various types of spinal implants have been used with the objective of minimizing spinal deformities while maximizing the spine and thoracic growth in a growing child with a spinal deformity. The aim of this study was to describe a classification system of growth friendly spinal implants to allow researchers and clinicians to have a common language and facilitate comparative studies. Growth friendly spinal implant systems fall into 3 categories based upon the forces of correction the implants exert on the spine, which are as follows: Distraction-based systems correct spinal deformities by mechanically applying a distractive force across a deformed segment with anchors at the top and bottom of the implants, which commonly attach to the spine, rib, and/or the pelvis. The present examples of distraction-based implants are spine-based or rib-based growing rods, vertical expandable titanium rib prosthesis, and remotely expandable devices. Compression-based systems correct spinal deformities with a compressive force applied to the convexity of the curve causing convex growth inhibition. This compressive force may be generated both mechanically at the time of implantation, as well as over time resulting from longitudinal growth of vertebral endplates hindered by the spinal implants. Examples of compression-based systems are vertebral staples and tethers. Guided growth systems correct spinal deformity by anchoring multiple vertebrae (usually including the apical vertebrae) to rods with mechanical forces including translation at the time of the initial implant. The majority of the anchors are not rigidly attached to the rods, thus permitting longitudinal growth over time as the anchors slide over the rods. Examples of guided growth systems include the Luque trolley and Shilla. Each system has its benefits and shortcomings. Knowledge of the fundamental principles upon which these systems are based may aid the clinician to choose an appropriate treatment for patients. Having a

  4. Comparison of intrathecal plain articaine and levobupivacaine with fentanyl for Caesarean section.

    Science.gov (United States)

    Demircioglu, Rüveyda I; Gozdemir, Muhammet; Usta, Burhanettin; Sert, Hüseyin; Karabayirli, Safinaz; Muslu, Bünyamin; Keskin, Esra A

    2016-12-01

    Articaine is used as a local anesthetic for outpatient surgery because it offers rapid onset of anesthesia and short duration motor block. Levobupivacaine is often preferred for Caesarean section. We evaluated the anesthetic characteristics of fentanyl-supplemented plain articaine and levobupivacaine for Caesarean section under combine spinal epidural anesthesia. Patients undergoing Caesarean section received in random order plain articaine 40 mg (Group A, n=50) or plain levobupivacaine 10 mg (Group L, n=50) mixed with fentanyl 20 µg intrathecally. The onset and duration of sensory and motor block, first analgesic request, and hemodynamic parameters were recorded. Onset times of maximum motor block were longer in Group L than Group A (P=0,001). Time to two-segment regression of sensory block were 70 min for Group A and 90 min group L (P=0.001). Times to complete regression of motor blockade were significantly longer in group L than group A (P =0,001). To have a faster onset and shorter duration of spinal anesthesia, we recommend the use of plain articaine for Caesarean section.

  5. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly; Ou, Kevin; Jackson, John K.; Letchford, Kevin; Cui, Jing; Wolf, Ki Tae; Graber, Florian; Zhao, Tom; Matsubara, Joanne A.; Burt, Helen; Chiao, Mu; Lin, Liwei

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved

  6. Comparative in Vivo Investigation of Intrathecal and Intracerebroventricular Administration with Melanocortin Ligands MTII and AGRP into Mice.

    Science.gov (United States)

    Adank, Danielle N; Lunzer, Mary M; Lensing, Cody J; Wilber, Stacey L; Gancarz, Amy M; Haskell-Luevano, Carrie

    2018-02-21

    Central administration of melanocortin ligands has been used as a critical technique to study energy homeostasis. While intracerebroventricular (ICV) injection is the most commonly used method during these investigations, intrathecal (IT) injection can be equally efficacious for the central delivery of ligands. Importantly, intrathecal administration can optimize exploration of melanocortin receptors in the spinal cord. Herein, we investigate comparative IT and ICV administration of two melanocortin ligands, the synthetic MTII (Ac-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-NH 2 ) MC4R agonist and agouti-related peptide [AGRP(87-132)] MC4R inverse agonist/antagonist, on the same batch of age-matched mice in TSE metabolic cages undergoing a nocturnal satiated paradigm. To our knowledge, this is the first study to test how central administration of these ligands directly to the spinal cord affects energy homeostasis. Results showed, as expected, that MTII IT administration caused a decrease in food and water intake and an overall negative energy balance without affecting activity. As anticipated, IT administration of AGRP caused weight gain, increase of food/water intake, and increase respiratory exchange ratio (RER). Unexpectantly, the prolonged activity of AGRP was notably shorter (2 days) compared to mice given ICV injections of the same concentrations in previous studies (7 days or more).1-4 It appears that IT administration results in a more sensitive response that may be a good approach for testing synthetic compound potency values ranging in nanomolar to high micromolar in vitro EC 50 values. Indeed, our investigation reveals that the spine influences a different melanocortin response compared to the brain for the AGRP ligand. This study indicates that IT administration can be a useful technique for future metabolic studies using melanocortin ligands and highlights the importance of exploring the role of melanocortin receptors in the spinal cord.

  7. Comparison of intrathecal clonidine and magnesium sulphate used as an adjuvant with hyperbaric bupivacaine in lower abdominal surgery

    Directory of Open Access Journals (Sweden)

    Mamta Khandelwal

    2017-01-01

    Full Text Available Background and Aims: Use of various adjuvants to spinal anaesthesia is a well-known modality to provide intra- and post-operative analgesia. This study was designed to evaluate and compare the analgesic efficacy of clonidine and magnesium when used as an additive to intrathecal 0.5% hyperbaric bupivacaine. Methods: Ninety patients of the American Society of Anesthesiologists' physical status grade I or II, scheduled for lower abdominal surgery under spinal anaesthesia, were randomly allocated into three groups. Group B received 3 mL of 0.5% hyperbaric bupivacaine with 1 mL of normal saline, Group C received 3 mL of 0.5% hyperbaric bupivacaine with 1 mL (30 μg of clonidine and Group M received 3 mL of 0.5% hyperbaric bupivacaine with 1 mL (50 mg magnesium sulphate. The primary outcome variable was duration of analgesia and secondary outcome variables included onset and duration of sensory and motor block, sedation level and adverse effects. Data were analysed with ANOVA, Kruskal–Wallis and Chi-square tests. Results: The time to first rescue analgesia was significantly (P < 0.01 longer in the Group C (330.7 ± 47.7 min than both Groups. Group M (246.3 ± 55.9 min showed significantly prolonged analgesia than Group B (134.4 ± 17.9 min. Group C and Group M showed significantly prolonged duration of both sensory and motor block compared to Group B. Conclusion: Intrathecal clonidine added to bupivacaine prolongs the duration of post-operative analgesia, and hastens the onset and prolongs the duration of sensory and motor block compared to magnesium or controls.

  8. Effects of intrathecal dexmedetomidine on shivering after spinal anesthesia for cesarean section: a double-blind randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Nasseri K

    2017-04-01

    Full Text Available Karim Nasseri,1,2 Negin Ghadami,1 Bijan Nouri2 1Department of Anesthesiology, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran; 2Social Determinants of Health Research Center, Kurdistan University of Medical Sciences, Sanandaj, Iran Background: Shivering is among the common troublesome complications of spinal anesthesia (SA, and causes discomfort and discontentment in parturients undergoing cesarean sections (CSs. The aim of this study was to investigate the effects of intrathecal dexmedetomidine in the prevention of shivering in those who underwent CS under SA.Subjects and methods: Fifty parturients planned for elective CSs under SA were enrolled in this prospective, double-blinded, controlled study and randomly divided into two equal groups. Spinal block was achieved with 12.5 mg 0.5% heavy bupivacaine plus 5 µg dexmedetomidine (BD group or 0.5 mL 0.9% normal saline (BN group. The incidence and intensity of shivering, peripheral and core body temperature, hemodynamic parameters, and adverse events was recorded.Results: The incidence of shivering was significantly higher in the BN group (52% than the BD group (24% (P=0.04. Likewise, the intensity of shivering was significantly higher in the BN group than the BD group (P=0.04. The incidence of adverse events, such as hypotension, nausea/vomiting, and bradycardia, was not significantly different between the two groups, although the grade of sedation was higher in the BD group than the BN group (P=0.004.Conclusion: We conclude that intrathecal dexmedetomidine is effective in lowering the incidence and intensity of shivering in parturients undergoing CSs under SA without major adverse effects. Keywords: dexmedetomidine, shivering, spinal anesthesia, cesarean sections, bupivacaine

  9. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  10. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  11. A cyclically actuated electrolytic drug delivery device

    KAUST Repository

    Yi, Ying; Buttner, Ulrich; Foulds, Ian G.

    2015-01-01

    This work, focusing on an implantable drug delivery system, presents the first prototype electrolytic pump that combines a catalytic reformer and a cyclically actuated mode. These features improve the release performance and extend the lifetime

  12. The Comparison of Intrathecal Morphine and IV Morphine PCA on Pain Control, Patient Satisfaction, Morphine Consumption, and Adverse Effects in Patients Undergoing Reduction Mammoplasty

    OpenAIRE

    Karamese, Mehtap; Akda?, Osman; Kara, ?nci; Y?ld?ran, Gokce Unal; Tosun, Zekeriya

    2015-01-01

    Background: Following breast reduction procedures, the level of postoperative pain can be severe, and sufficient pain control influences a patient's physiological, immunological, and psychological status. Objective: The aim of this study was to examine the use of intrathecal morphine (ITM) in breast reduction surgery with patient-controlled analgesia (PCA). Methods: Sixty-two female patients who underwent breast reductions with the same technique participated in this study. The study group (I...

  13. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-01-17

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under "real-time" and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to "real-time" conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict "real-time" release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under "real-time" and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  15. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  16. Near-infrared induced release for localized on-demand drug delivery

    NARCIS (Netherlands)

    Vertommen, M.A.M.E.

    2009-01-01

    By non-invasive external triggering of drug release from an implant, pulsewise administration can be realized according to the patient’s needs and at specific locations in the human body. In comparison to more traditional delivery forms (e.g. oral or by injection), externally triggered drug release

  17. Electrodeposited silk coatings for functionalized implant applications

    Science.gov (United States)

    Elia, Roberto

    The mechanical and morphological properties of titanium as well as its biocompatibility and osteoinductive characteristics have made it the material of choice for dental implant systems. Although the success rate of titanium implants exceeds 90% in healthy individuals, a large subset of the population has one or more risk factors that inhibit implant integration. Treatments and coatings have been developed to improve clinical outcomes via introduction of appropriate surface topography, texture and roughness or incorporation of bioactive molecules. It is essential that the coatings and associated deposition techniques are controllable and reproducible. Currently, methods of depositing functional coatings are dictated by numerous parameters (temperature, particle size distribution, pH and voltage), which result in variable coating thickness, strength, porosity and weight, and hinder or preclude biomolecule incorporation. Silk is a highly versatile protein with a unique combination of mechanical and physical properties, including tunable degradation, biocompatibility, drug stabilizing capabilities and mechanical properties. Most recently an electrogelation technique was developed which allows for the deposition of gels which dry seamlessly over the contoured topography of the conductive substrate. In this work we examine the potential use of silk electrogels as mechanically robust implant coatings capable of sequestering and releasing therapeutic agents. Electrodeposition of silk electrogels formed in uniform electric fields was characterized with respect to field intensity and deposition time. Gel formation kinetics were used to derive functions which allowed for the prediction of coating deposition over a range of process and solution parameters. Silk electrogel growth orientation was shown to be influenced by the applied electric field. Coatings were reproducible and tunable via intrinsic silk solution properties and extrinsic process parameters. Adhesion was

  18. Advances in drug delivery to the posterior segment.

    Science.gov (United States)

    Pearce, William; Hsu, Jason; Yeh, Steven

    2015-05-01

    Emerging developments and research for drug delivery to the posterior segment offer a promising future for the treatment of vitreoretinal disease. As new technologies enter the market, clinicians should be aware of new indications and ongoing clinical trials. This review summarizes the advantages and shortcomings of the most commonly used drug delivery methods, including vitreous dynamics, physician sustainability and patient preferences. Currently available, intravitreal, corticosteroid-release devices offer surgical and in-office management of retinal vascular disease and posterior uveitis. The suprachoroidal space offers a new anatomic location for the delivery of lower dose medications directly to the target tissue. Implantable drug reservoirs would potentially allow for less frequent intravitreal injections reducing treatment burdens and associated risks. Newer innovations in encapsulated cell technology offer promising results in early clinical trials. Although pars plana intravitreal injection remains the mainstay of therapy for many vitreoretinal diseases, targeted delivery and implantable eluting devices are rapidly demonstrating safety and efficacy. These therapeutic modalities offer promising options for the vitreoretinal therapeutic landscape.

  19. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  20. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  2. Fluorouracil implants caused a diaphragmatic tumor to be misdiagnosed as liver metastasis: a case report

    International Nuclear Information System (INIS)

    Shen, Yang-Yang; Qin, Hong-Wei; Zhang, Jian-Bo; Wang, Zhen-Dan; Li, Pang; Pang, Kai; Zhang, Bo; Li, Sheng; Cui, Kai

    2016-01-01

    Fluorouracil implants are widely used in peritoneal interstitial chemotherapy. Curative effects have been obtained, but implants have also caused some complications. We performed an analysis of a 66-year-old male patient’s case history, as well as conventional pathological analysis and Raman spectroscopic detection of the diaphragmatic tumor. We also analyzed the underlying causes of this condition to prevent complications and reduce misdiagnoses in future cases. The patient had a history of peritoneal fluorouracil implantation. Pathological analysis of the diaphragmatic mass revealed foreign particles, and Raman detection showed that the mass contained fluorouracil. Fluorouracil implants may persist due to the high concentrations of this drug used in peritoneal chemotherapy. This finding should provide guidance and improve the application of peritoneal implants. In clinical trials, and the diagnosis of liver metastasis should be based on pathological results

  3. Electro active polymers : novel bio-electrodes and implants for urinary continence

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopalan, S.; Sawan, M.; Savadogo, O. [Ecole Polytechnique, Montreal, PQ (Canada). Laboratoire de nouveaux materiaux pour les systemes electrochimiques et energetiques

    2006-07-01

    This paper presented a technical solution to spinal cord injuries that result in urinary bladder dysfunction. It involves miniaturized implants based on polypyrrole, an electroactive polymer, as smart drug-eluting electrodes for neural stimulation to restore bladder function. The nerve-electrode interface is the most vulnerable point in the design and operation of neuro-electronic implants. The main disadvantages are decreased impedance and protein build-up at the stimulation site due to an inflammatory reaction. Polypyrrole is a naturally conducting polymer having both electron-conducting properties as well as actuating properties, rendering it suitable as a drug-eluting electrode for a neurostimulator. Polypyrrole electrochemically coated on platinum increases biocompatibility and reduces electric impedance by increasing the surface area of the electrode. When electrically stimulated, polypyrrole also serves as a matrix to release a negatively-charged anti-inflammatory drug fosfosal. This technology may prove useful in reconstructing a severely damaged bladder through electroactive biomaterials. Polyelectrolyte gels, such as poly(sodium) acrylate, reversibly contract and relax when activated electrically or under the influx of divalent ions. These artificial muscles can be connected to a polypyrrole strain sensor to alert the microcontroller to activate the sphincter muscle, thereby creating an artificial bladder.

  4. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  5. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  6. Management of antithrombotic therapy during cardiac implantable device surgery.

    Science.gov (United States)

    AlTurki, Ahmed; Proietti, Riccardo; Birnie, David H; Essebag, Vidal

    2016-06-01

    Anticoagulants are commonly used drugs that are frequently encountered during device placement. Deciding when to halt or continue the use of anticoagulants is a balance between the risks of thromboembolism versus bleeding. Patients taking warfarin with a high risk of thromboembolism should continue to take their warfarin without interruption during device placement while ensuring their international normalized ratio remains below 3. For patients who are taking warfarin and have low risk of thromboembolism, either interrupted or continued warfarin may be used, with no evidence to clearly support either strategy. There is little evidence to support continuing direct acting oral anticoagulants (DOACs) for device implantation. The timing of halting these medications depends largely on renal function. If bleeding occurs, warfarin׳s anticoagulation effect is reversible with vitamin K and activated prothrombin complex concentrate. There are no DOAC reversal agents currently available, but some are under development. Regarding antiplatelet agents, aspirin alone can be safely continued while clopidogrel alone may also be continued, but with a slightly higher bleeding risk. Dual antiplatelet therapy for bare-metal stent/drug-eluting stent implanted within 4 weeks/6 months, respectively, should be continued due to high risk of stent thrombosis; however, if they are implanted after this period, then clopidogrel can be halted 5 days before the procedure and resumed soon after, while aspirin is continued. If the patient is taking both aspirin and warfarin, aspirin should be halted 5 days prior to the procedure, while warfarin is continued.

  7. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  8. Manipulation of reproductive seasonality using melatonin implantation in Anglo-Nubian does treated with controlled internal drug release and equine chorionic gonadotropin during the nonbreeding season.

    Science.gov (United States)

    El-Mokadem, M Y; El-Din, A N M Nour; Ramadan, T A; Rashad, A M A; Taha, T A; Samak, M A

    2017-06-01

    The objective of this study was to compare the efficiency of hormonal treatments on ovarian activity and reproductive performance in anestrous Anglo-Nubian does during the nonbreeding season (February to May). A total of 48 multiparous does were divided into 2 groups (24 lactating does and 24 dry does). In each group, animals were allocated randomly into 2 equal subgroups (12 does each). In the first subgroup, does received a single 18-mg melatonin implant for 42 d followed by a controlled internal drug release (CIDR) device for 19 d in conjunction with 500 IU of equine chorionic gonadotropin (eCG) i.m. on the day of CIDR device removal. The second subgroup received CIDR combined with eCG in parallel with the first subgroup. Melatonin implantation induced a luteotrophic effect, expressed as an increasing number of corpora lutea, increased serum progesterone concentration, and reduced estradiol concentration. Regardless of treatment, dry does showed greater value of progesterone concentration. With the advancement of day of treatment, number of total follicles, small follicles, and medium follicles tended to increase to the greatest values at the day of CIDR device insertion. Furthermore, at day of mating, the numbers of large follicles reached the greatest value, which was associated with the lowest value of the number of corpora lutea. At day of mating, serum progesterone concentration achieved the lowest value, which increased until d 56 of pregnancy. The estradiol:progesterone ratio showed the opposite trend. The detrimental effect of reproductive seasonality, expressed as cessation of estrus behavior and fertile mating during the nonbreeding season, was successfully alleviated by the CIDR-eCG protocol. Furthermore, melatonin implantation in conjunction with the CIDR-eCG protocol enhanced conception rate and fecundity at d 28 of pregnancy and prolificacy at d 56 of pregnancy compared with does that were not implanted. Interestingly, does that failed to conceive

  9. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    Total knee arthroplasty often results in marked postoperative pain. A recent meta-analysis supports the use of femoral nerve block or alternatively spinal injection of morphine plus local anaesthetic for post-operative analgesia. On the other hand, the use of intrathecal morphine may be associated with a large number of distressing side effects (itching, urinary retention, nausea and vomiting, delayed respiratory depression). The aim of this study was to compare the effectiveness of femoral nerve block and low dose intrathecal morphine in post-operative analgesia after primary unilateral total knee arthroplasty. Fifty-two consecutive patients scheduled for primary unilateral total knee arthroplasty were allocated to the intrathecal morphine group (ITM group) or to the femoral nerve block group (FNB group). In ITM group a subarachnoid puncture was performed at the L3-L4 inter-vertebral space with hyperbaric bupivacaine 15 mg plus 100 mcg of preservative-free morphine. Patients allocated to the FNB group received a single-injection ultrasound-assisted femoral nerve block with ropivacaine 0.75% 25 ml before the spinal injection of hyperbaric bupivacaine 15 mg. All patients received postoperative patient-controlled-analgesia (PCA) morphine, using a 1-mg bolus and a 5-minute lockout period. Data were analyzed using Student t test or two-way analysis of variance (ANOVA) for repeated measures with time and treatment as the 2 factors. Post hoc comparisons were performed by Bonferroni test. Statistical significance for all test was a p value < 0.05. Patient characteristics were similar between the 2 groups. We found a statistically significant differences in postoperative pain between the two groups: ITM group had the lower visual analogic pain score (VAS) values. Morphine consumption was lower in the ITM group: average consumption within the first 6 hours was 0.9 mg in IT group compared to 3.1 mg in FNB group; at 12 h 4.2 mg vs 6.3 mg; at 24 h 6.9 mg vs 10.3 mg; at 48 h 9

  10. Enhanced osteoblast adhesion to drug-coated anodized nanotubular titanium surfaces

    Directory of Open Access Journals (Sweden)

    George E Aninwene II

    2008-06-01

    Full Text Available George E Aninwene II1, Chang Yao2, Thomas J Webster21Department of Biochemical Engineering, University of Maryland, Baltimore, MD; 2Division of Engineering, Brown University, Providence, RI, USAAbstract: Current orthopedic implants have functional lifetimes of only 10–15 years due to a variety of reasons including infection, extensive inflammation, and overall poor osseointegration (or a lack of prolonged bonding of the implant to juxtaposed bone. To improve properties of titanium for orthopedic applications, this study anodized and subsequently coated titanium with drugs known to reduce infection (penicillin/streptomycin and inflammation (dexamethasone using simple physical adsorption and the deposition of such drugs from simulated body fluid (SBF. Results showed improved drug elution from anodized nanotubular titanium when drugs were coated in the presence of SBF for up to 3 days. For the first time, results also showed that the simple physical adsorption of both penicillin/streptomycin and dexamethasone on anodized nanotubular titanium improved osteoblast numbers after 2 days of culture compared to uncoated unanodized titanium. In addition, results showed that depositing such drugs in SBF on anodized titanium was a more efficient method to promote osteoblast numbers compared to physical adsorption for up to 2 days of culture. In addition, osteoblast numbers increased on anodized titanium coated with drugs in SBF for up to 2 days of culture compared to unanodized titanium. In summary, compared to unanodized titanium, this preliminary study provided unexpected evidence of greater osteoblast numbers on anodized titanium coated with either penicillin/streptomycin or dexamethasone using simple physical adsorption or when coated with SBF; results which suggest the need for further research on anodized titanium orthopedic implants possessing drug-eluting nanotubes.Keywords: anodization, titanium, adhesion, simulated body fluid, nanotubes

  11. A remotely operated drug delivery system with dose control

    KAUST Repository

    Yi, Ying

    2017-05-08

    “On demand” implantable drug delivery systems can provide optimized treatments, due to their ability to provide targeted, flexible and precise dose release. However, two important issues that need to be carefully considered in a mature device include an effective actuation stimulus and a controllable dose release mechanism. This work focuses on remotely powering an implantable drug delivery system and providing a high degree of control over the released dose. This is accomplished by integration of a resonance-based wireless power transfer system, a constant voltage control circuit and an electrolytic pump. Upon the activation of the wireless power transfer system, the electrolytic actuator is remotely powered by a constant voltage regardless of movements of the device within an effective range of translation and rotation. This in turn contributes to a predictable dose release rate and greater flexibility in the positioning of external powering source. We have conducted proof-of-concept drug delivery studies using the liquid drug in reservoir approach and the solid drug in reservoir approach, respectively. Our experimental results demonstrate that the range of flow rate is mainly determined by the voltage controlled with a Zener diode and the resistance of the implantable device. The latter can be adjusted by connecting different resistors, providing control over the flow rate to meet different clinical needs. The flow rate can be maintained at a constant level within the effective movement range. When using a solid drug substitute with a low solubility, solvent blue 38, the dose release can be kept at 2.36μg/cycle within the effective movement range by using an input voltage of 10Vpp and a load of 1.5 kΩ, which indicates the feasibility and controllability of our system without any complicated closed-loop sensor.

  12. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  13. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  14. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  15. Implantable batteryless device for on-demand and pulsatile insulin administration

    Science.gov (United States)

    Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin

    2017-04-01

    Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.

  16. Accidental epidural injection of Atropine

    Directory of Open Access Journals (Sweden)

    Udayan Bakshi

    2013-01-01

    Full Text Available Intrathecal injection of drugs for anesthesia, regional analgesia, and chronic pain management are common practice now. Local anesthetic, adjuvants, and opioids are in common use. Human error in the Operation Theater and the Intensive Care Unit setup is also known and reported, due to stress and overwork. A case of unintentional atropine injection intrathecally, which was closely observed for any untoward effects, is reported here.

  17. Recent developments in drug eluting devices with tailored interfacial properties.

    Science.gov (United States)

    Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon

    2017-11-01

    Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. All-cause mortality after drug-eluting stent implantation in African-Americans.

    Science.gov (United States)

    Poludasu, Shyam; Cavusoglu, Erdal; Khan, Waqas; Marmur, Jonathan D

    2008-12-01

    Recent studies have questioned the safety of drug-eluting stents because of a higher incidence of late stent thrombosis, raising the possibility that drug-eluting stents may be associated with an increased mortality. The effect of drug-eluting stents on mortality in African-Americans is unknown. We evaluated 628 African-American patients (354 patients treated with drug-eluting stents and 274 patients treated with bare metal stents) between January 2003 and August 2005, using data from our bolus-only platelet glycoprotein IIb/IIIa inhibitor database. The primary end point was all-cause mortality obtained using social security death index. After a mean follow-up of 3+/-0.9 years, the mortality rate in the bare metal stents group was 12.8% compared with 7.1% in the drug-eluting stents group [adjusted P value=0.19; hazard ratio (HR) for bare metal stents group compared with drug-eluting stents group for death=1.4; 95% confidence interval (CI): 0.8-2.4]. In a subgroup analysis, patients presenting with acute coronary syndrome had a higher mortality when treated with bare metal stents compared with drug-eluting stents (17.1 vs. 6.3%, P=0.022; HR=2.2; 95% CI: 1.1-4.4). Patients with chronic kidney disease (all patients with creatinine >1.5 mg/dl) also had a higher mortality with bare metal stents compared with drug-eluting stents (36.7 vs. 20.4%, P=0.044; HR=2.3; 95% CI: 1.02-5.2). Drug-eluting stents seem to be safe in African-Americans and may improve survival in certain subgroups such as patients with acute coronary syndromes and chronic kidney disease.

  19. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  20. Intrathecal morphine attenuates acute opioid tolerance secondary to remifentanil infusions during spinal surgery in adolescents

    Directory of Open Access Journals (Sweden)

    Tripi PA

    2015-09-01

    Full Text Available Paul A Tripi,1 Matthew E Kuestner,1 Connie S Poe-Kochert,2 Kasia Rubin,1 Jochen P Son-Hing,2 George H Thompson,2 Joseph D Tobias3 1Division of Pediatric Anesthesiology, 2Division of Pediatric Orthopaedic Surgery, Rainbow Babies and Children's Hospital, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, 3Department of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH, USA Introduction: The unique pharmacokinetic properties of remifentanil with a context-sensitive half-life unaffected by length of infusion contribute to its frequent use during anesthetic management during posterior spinal fusion in children and adolescents. However, its intraoperative administration can lead to increased postoperative analgesic requirements, which is postulated to be the result of acute opioid tolerance with enhancement of spinal N-methyl-D-aspartate receptor function. Although strategies to prevent or reduce tolerance have included the coadministration of longer acting opioids or ketamine, the majority of these studies have demonstrated little to no benefit. The current study retrospectively evaluates the efficacy of intrathecal morphine (ITM in preventing hyperalgesia following a remifentanil infusion.Methods: We retrospectively analyzed 54 patients undergoing posterior spinal fusion with segmental spinal instrumentation, to evaluate the effects of ITM on hyperalgesia from remifentanil. Patients were divided into two groups based on whether they did or did not receive remifentanil during the surgery: no remifentanil (control group (n=27 and remifentanil (study group (n=27. Data included demographics, remifentanil dose and duration, Wong–Baker visual analog scale postoperative pain scores, and postoperative intravenous morphine consumption in the first 48 postoperative hours.Results: The demographics of the two study groups were similar. There were no differences in the Wong–Baker visual analog

  1. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  2. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  3. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Susumu, E-mail: susumu1029@gmail.com; Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro [Toho University School of Medicine, Department of Respiratory Medicine (Japan); Shibuya, Kazutoshi [Toho University School of Medicine, Department of Pathology (Japan); Homma, Sakae [Toho University School of Medicine, Department of Respiratory Medicine (Japan)

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  4. Synergistic effects of bisphosphonate and calcium phosphate nanoparticles on peri-implant bone responses in osteoporotic rats.

    Science.gov (United States)

    Alghamdi, Hamdan S; Bosco, Ruggero; Both, Sanne K; Iafisco, Michele; Leeuwenburgh, Sander C G; Jansen, John A; van den Beucken, Jeroen J J P

    2014-07-01

    The prevalence of osteoporosis will increase within the next decades due to the aging world population, which can affect the bone healing response to dental and orthopedic implants. Consequently, local drug targeting of peri-implant bone has been proposed as a strategy for the enhancement of bone-implant integration in osteoporotic conditions. In the present study, an established in-vivo femoral condyle implantation model in osteoporotic and healthy bone is used to analyze the osteogenic capacity of titanium implants coated with bisphosphonate (BP)-loaded calcium phosphate nanoparticles (nCaP) under compromised medical conditions. After 4 weeks of implantation, peri-implant bone volume (%BV; by μCT) and bone area (%BA; by histomorphometry) were significantly increased within a distance of 500 μm from implant surfaces functionalized with BP compared to control implants in osteoporotic and healthy conditions. Interestingly, the deposition of nCaP/BP coatings onto implant surfaces increased both peri-implant bone contact (%BIC) and volume (%BV) compared to the deposition of nCaP or BP coatings individually, in osteoporotic and healthy conditions. The results of real-time PCR revealed similar osteogenic gene expression levels to all implant surfaces at 4-weeks post-implantation. In conclusion, simultaneous targeting of bone formation (by nCaP) and bone resorption (by BP) using nCaP/BP surface coatings represents an effective strategy for synergistically improvement of bone-implant integration, especially in osteoporotic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Fluocinolone acetonide ophthalmic--Bausch & Lomb: fluocinolone acetonide Envision TD implant.

    Science.gov (United States)

    2005-01-01

    Bausch & Lomb and Control Delivery Systems have developed an intravitreal implant that can deliver the corticosteroid fluocinolone acetonide [fluocinolone acetonide implant, Retisert] to posterior eye tissue for up to 3 years. The implant uses Bausch & Lomb's Envision TD technology. This fluocinolone acetonide implant has been designed for the treatment of non-infectious uveitis affecting the posterior segment of the eye and other eye disorders, which benefit from local anti-inflammatory therapy. In July 2003, Bausch & Lomb assumed all responsibility for day-to-day clinical development and regulatory activities relating to fluocinolone acetonide implant development from Control Delivery Systems. In May 2002, Control Delivery systems and Bausch & Lomb formally amended their budget for their license and development agreement. Bausch & Lomb will increase its funding to support the development of agents for the treatment of diabetic macular oedema, posterior uveitis and wet age-related macular degeneration to USD $206 million through to 2008. In January 2004, Bausch & Lomb decided to focus development of the fluocinolone acetonide implant in only one indication, non-infectious uveitis affecting the posterior segment of the eye. It had been in development for other indications, including macular oedema and age-related macular degeneration. However, these will be targeted with later-generation implant technologies, different drugs, or combinations of both. The implant delivering fluocinolone acetonide 0.59 mg or 2.1mg has completed enrollment in two pivotal 3-year phase IIb/III trials in the US, Canada, Australia and Asia for the treatment of posterior uveitis. Enrollment in these multicenter randomised, double-masked studies was closed in May 2003. Bausch & Lomb was expected to file an NDA with the US FDA for the use of the agent in the treatment of uveitis in mid-2003. However, in February 2003, the company reported that, after a review of various filing strategies

  6. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  7. Preparation and biocompatibility study of in situ forming polymer implants in rat brains.

    Science.gov (United States)

    Nasongkla, Norased; Boongird, Atthaporn; Hongeng, Suradej; Manaspon, Chawan; Larbcharoensub, Noppadol

    2012-02-01

    We describe the development of polymer implants that were designed to solidify once injected into rat brains. These implants comprised of glycofurol and copolymers of D: ,L: -lactide (LA), ε-caprolactone and poly(ethylene glycol) (PLECs). Scanning electron microscopy (SEM) and gel permeation chromatography (GPC) showed that the extent of implant degradation was increased with LA: content in copolymers. SEM analysis revealed the formation of porosity on implant surface as the degradation proceeds. PLEC with 19.3% mole of LA: was chosen to inject in rat brains at the volume of 10, 25 and 40 μl. Body weights, hematological and histopathological data of rats treated with implants were evaluated on day 3, 6, 14, 30 and 45 after the injection. Polymer solution at the injection volume of 10 μl were tolerated relatively well compared to those of 25 and 40 μl as confirmed by higher body weight and healing action (fibrosis tissue) 30 days after treatment. The results from this study suggest a possible application as drug delivery systems that can bypass the blood brain barrier.

  8. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  9. Design of a long-term antipsychotic in situ forming implant and its release control method and mechanism.

    Science.gov (United States)

    Wang, Lexi; Wang, Aiping; Zhao, Xiaolei; Liu, Ximing; Wang, Dan; Sun, Fengying; Li, Youxin

    2012-05-10

    Two kinds of in situ forming implants (ISFIs) of atypical antipsychotics, risperidone and its 9-hydroxy active metabolite, paliperidone, using poly(lactide-co-glycolide)(PLGA) as carrier, were investigated. Significant difference was observed in the solution-gel transition mechanism of the two systems: homogeneous system of N-methyl-2-pyrrolidone (NMP) ISFI, in which drug was dissolved, and heterogeneous system of dimethyl sulfoxide (DMSO) ISFI, in which drug was dispersed. Fast solvent extractions were found in both systems, but in comparison with the high drug release rate from homogeneous system of drug/polymer/NMP, a fast solvent extraction from the heterogeneous system of drug/polymer/DMSO was not accompanied by a high drug release rate but a rapid solidification of the implant, which resulted in a high drug retention, well-controlled initial burst and slow release of the drug. In vivo study on beagle dogs showed a more than 3-week sustained release with limited initial burst. Pharmacologic evaluation on optimized paliperidone ISFIs presented a sustained-suppressing effect from 1 day to 38 day on the MK-801 induced schizophrenic behavior mice model. A long sustained-release antipsychotic ISFI of 50% drug loading and controlled burst release was achieved, which indicated a good potential in clinic application. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Effect of Acupuncture on Post-implant Paresthesia

    OpenAIRE

    Sant’Anna, Crischina Branco Marques; Zuim, Paulo Renato Junqueira; Brandini, Daniela Atili; Guiotti, Aimée Maria; Vieira, Joao Batista; Turcio, Karina Helga Leal

    2017-01-01

    Paresthesia is defined as an alteration in local sensibility, associated with numbness, tingling, or unpleasant sensations caused by nerve lesions or irritation. It can be temporary or permanent. The treatment protocol for facial paresthesia is primarily based on the use of drugs and implant removal, which may not be completely effective or may require other risk exposure when there is no spontaneous regression. However, other therapeutic modalities such as acupuncture can be used. The aim of...

  11. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  12. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  13. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  14. Degradation products of irradiated haloperidol: implications for the development of an implantible delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Booker, J

    1988-01-01

    Haloperidol was chosen as a model compound to determine whether the degradation products created by sterilizing dose of gamma radiation would contaminate an implantible delivery device and be hazardous to the health of the person using it. Acrolein, chlorobenzene, and several other products were identified among the degradation products. They were quantitated and evaluated as being potentially dangerous. It is recommended that the development protocol for a radiation-sterilized, implantible drug include the identification and evaluation of the degradation products.

  15. Degradation products of irradiated haloperidol: implications for the development of an implantible delivery system

    International Nuclear Information System (INIS)

    Booker, J.

    1988-01-01

    Haloperidol was chosen as a model compound to determine whether the degradation products created by sterilizing dose of gamma radiation would contaminate an implantible delivery device and be hazardous to the health of the person using it. Acrolein, chlorobenzene, and several other products were identified among the degradation products. They were quantitated and evaluated as being potentially dangerous. It is recommended that the development protocol for a radiation-sterilized, implantible drug include the identification and evaluation of the degradation products. (author)

  16. Intracranial EEG fluctuates over months after implanting electrodes in human brain

    Science.gov (United States)

    Ung, Hoameng; Baldassano, Steven N.; Bink, Hank; Krieger, Abba M.; Williams, Shawniqua; Vitale, Flavia; Wu, Chengyuan; Freestone, Dean; Nurse, Ewan; Leyde, Kent; Davis, Kathryn A.; Cook, Mark; Litt, Brian

    2017-10-01

    Objective. Implanting subdural and penetrating electrodes in the brain causes acute trauma and inflammation that affect intracranial electroencephalographic (iEEG) recordings. This behavior and its potential impact on clinical decision-making and algorithms for implanted devices have not been assessed in detail. In this study we aim to characterize the temporal and spatial variability of continuous, prolonged human iEEG recordings. Approach. Intracranial electroencephalography from 15 patients with drug-refractory epilepsy, each implanted with 16 subdural electrodes and continuously monitored for an average of 18 months, was included in this study. Time and spectral domain features were computed each day for each channel for the duration of each patient’s recording. Metrics to capture post-implantation feature changes and inflexion points were computed on group and individual levels. A linear mixed model was used to characterize transient group-level changes in feature values post-implantation and independent linear models were used to describe individual variability. Main results. A significant decline in features important to seizure detection and prediction algorithms (mean line length, energy, and half-wave), as well as mean power in the Berger and high gamma bands, was observed in many patients over 100 d following implantation. In addition, spatial variability across electrodes declines post-implantation following a similar timeframe. All selected features decreased by 14-50% in the initial 75 d of recording on the group level, and at least one feature demonstrated this pattern in 13 of the 15 patients. Our findings indicate that iEEG signal features demonstrate increased variability following implantation, most notably in the weeks immediately post-implant. Significance. These findings suggest that conclusions drawn from iEEG, both clinically and for research, should account for spatiotemporal signal variability and that properly assessing the iEEG in

  17. Tumor treatment by sustained intratumoral release of cisplatin: effects of drug alone and combined with radiation

    International Nuclear Information System (INIS)

    Yapp, Donald T.T.; Lloyd, David K.; Zhu, Julian; Lehnert, Shirley M.

    1997-01-01

    Purpose: The effect of intratumoral delivery of cisplatin to a mouse tumor model (RIF-1) by means of a biodegradable polymer implant with and without radiation was studied. Methods and Materials: The polymer bis(p-carboxyphenoxy)propane-sebacic acid (CPP:SA; 80:20) and its degradation products have been characterized. Polymer rods (8 x 0.5 mm) containing 17% cisplatin by weight were prepared by extrusion, and the in vitro degradation rate measured. The implants were placed into mouse tumors and their effect (with and without radiation) on tumor growth delay studied. The levels of Pt in the mouse kidney, tumor, and blood plasma at selected intervals after implant were also determined. These results were compared with those obtained when cisplatin was delivered systematically. Results: When cisplatin was delivered by the polymer implants, higher levels were present in the tumor for longer time periods (cf. systemic delivery of the drug). For both nonirradiated and irradiated tumors, those treated with the polymer implants had significantly longer tumor growth delays compared to nonimplanted controls and to systematically treated tumors. Conclusions: The results show that intratumoral delivery of cisplatin is more efficient than systemic delivery. Using the biodegradable polymer implant, higher doses of cisplatin can be tolerated by the animal as the drug is localized within the tumor, and the high levels of the drug in the tumor can be maintained for an extended period of time. When radiation is given in conjunction with cisplatin, the tumor response is supraadditive for all modes of cisplatin administration but is potentiated to a greater extent when cisplatin is delivered through the polymer implant. The greatest effect is seen for treatment with cisplatin delivered by polymer implant combined with fractionated radiation

  18. Customizable orthopaedic oncology implants: one institution's experience with meeting current IRB and FDA requirements.

    Science.gov (United States)

    Willis, Alexander R; Ippolito, Joseph A; Patterson, Francis R; Benevenia, Joseph; Beebe, Kathleen S

    2016-01-01

    Customizable orthopaedic implants are often needed for patients with primary malignant bone tumors due to unique anatomy or complex mechanical problems. Currently, obtaining customizable orthopaedic implants for orthopaedic oncology patients can be an arduous task involving submitting approval requests to the Institutional Review Board (IRB) and the Food and Drug Administration (FDA). There is great potential for the delay of a patient's surgery and unnecessary paperwork if the submission pathways are misunderstood or a streamlined protocol is not in place. The objective of this study was to review the existing FDA custom implant approval pathways and to determine whether this process was improved with an institutional protocol. An institutional protocol for obtaining IRB and FDA approval for customizable orthopaedic implants was established with the IRB at our institution in 2013. This protocol was approved by the IRB, such that new patients only require submission of a modification to the existing protocol with individualized patient information. During the two-year period of 2013-2014, eight patients were retrospectively identified as having required customizable implants for various orthopaedic oncology surgeries. The dates of request for IRB approval, request for FDA approval, and total time to surgery were recorded, along with the specific pathway utilized for FDA approval. The average patient age was 12 years old (7-21 years old). The average time to IRB approval of a modification to the pre-approved protocol was 14 days (7-21 days). Average time to FDA approval after submission of the IRB approval to the manufacturer was 12.5 days (7-19 days). FDA approval was obtained for all implants as compassionate use requests in accordance with Section 561 of the Federal Food Drug and Cosmetic Act's expanded access provisions. Establishment of an institutional protocol with pre-approval by the IRB can expedite the otherwise time-consuming and complicated

  19. Effect of embedded dexamethasone in cochlear implant array on insertion forces in an artificial model of scala tympani.

    Science.gov (United States)

    Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier

    2015-02-01

    Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.

  20. An electro-conductive fluid as a responsive implant for the controlled stimuli-release of diclofenac sodium.

    Science.gov (United States)

    Bijukumar, Divya; Choonara, Yahya E; Kumar, Pradeep; du Toit, Lisa C; Pillay, Viness

    2016-11-01

    The purpose of this study was to develop an electro-responsive co-polymeric (ERP) implantable gel from polyethylene glycol (PEG), sodium polystyrene sulphonate (NaPss), polyvinyl alcohol (PVA), and diethyl acetomidomalonate (DAA) for electro-liberation of the model drug diclofenac sodium. Various physicochemical and physicomechanical characterization tests were undertaken on the synthesized drug-free gel (ERP G1) and drug-loaded gel (ERP G2). The ability of the gel to release diclofenac sodium following electrical stimulation was evaluated using a galvanostat while Molecular Mechanics (MM) simulations were performed to elucidate the experimental mechanisms. A stable electro-active gel exhibiting superior cycling stability was produced with desirable rheological properties, rigidity (BHN = 35.4 N ± 0.33 N/mm 2 ; resilience = 10.91 ± 0.11%), thermal properties (T g  ≈ 70 °C; T c  ≈ 200 °C) and homogeneous morphology. "ON-OFF" pursatile gradual drug release (37-94% from t 30 min -t 180   min ) kinetics was observed upon applying electric stimulation intermittently, indicating that drug release from the gel was electrically controlled. Overall, the galvanometric and MM evaluation ascertained the suitability of the PEG/NaPss/PVA ERP-Gel for application as a subcutaneously injectable drug delivery implant.

  1. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  2. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan

    2012-07-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  3. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan; Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  4. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    Science.gov (United States)

    Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O2) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O2-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O2 pressure (pO2) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO2 to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases. PMID:22224628

  5. An Overview of Clinical and Commercial Impact of Drug Delivery Systems

    Science.gov (United States)

    Anselmo, Aaron C.; Mitragotri, Samir

    2014-01-01

    Drug delivery systems are widely researched and developed to improve the delivery of pharmaceutical compounds and molecules. The last few decades have seen a marked growth of the field fueled by increased number of researchers, research funding, venture capital and the number of start-ups. Collectively, the growth has led to novel systems that make use of micro/nano-particles, transdermal patches, inhalers, drug reservoir implants and antibody-drug conjugates. While the increased research activity is clearly an indication of proliferation of the field, clinical and commercial translation of early-stage research ideas is critically important for future growth and interest in the field. Here, we will highlight some of the examples of novel drug delivery systems that have undergone such translation. Specifically, we will discuss the developments, advantages, limitations and lessons learned from: (i) microparticle-based depot formulations, (ii) nanoparticle-based cancer drugs, (iii) transdermal systems, (iv) oral drug delivery systems, (v) pulmonary drug delivery, (vi) implants and (vii) antibody-drug conjugates. These systems have impacted treatment of many prevalent diseases including diabetes, cancer and cardiovascular diseases, among others. At the same time, these systems are integral and enabling components of products that collectively generate annual revenues exceeding US $100 billion. These examples provide strong evidence of the clinical and commercial impact of drug delivery systems. PMID:24747160

  6. Inhibitory effect of sequential combined chemotherapy and radiotherapy on growth of implanted tumor in mice

    International Nuclear Information System (INIS)

    Okada, Kouji

    1983-01-01

    Sequential chemotherapy using FT-207, adriamycin and mitomycin C followed by radiotherapy was attempted to achieve effective inhibition against implanted tumor in C57BL/6 black mice bearing YM-12 tumors. Sequential combined chemotherapy was more effective than single drug chemotherapy or combined chemotherapy of other drugs. Addition of radiotherapy to the sequential combined chemotherapy was successful for enhancing therapeutic effect. (author)

  7. Fabrication and characterization of a rapid prototyped tissue engineering scaffold with embedded multicomponent matrix for controlled drug release

    DEFF Research Database (Denmark)

    Chen, Muwan; Le, Dang Q S; Hein, San

    2012-01-01

    Bone tissue engineering implants with sustained local drug delivery provide an opportunity for better postoperative care for bone tumor patients because these implants offer sustained drug release at the tumor site and reduce systemic side effects. A rapid prototyped macroporous polycaprolactone......, this scaffold can fulfill the requirements for both bone tissue engineering and local sustained release of an anticancer drug in vitro. These results suggest that the scaffold can be used clinically in reconstructive surgery after bone tumor resection. Moreover, by changing the composition and amount...... of individual components, the scaffold can find application in other tissue engineering areas that need local sustained release of drug....

  8. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  9. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  10. Evaluation of the effect of transdermal nitroglycerine patch on intrathecal dexmedetomidine as additive, on postoperative analgesia after abdominal hysterectomy

    Directory of Open Access Journals (Sweden)

    Rama Chatterji

    2017-01-01

    Full Text Available Aim: The aim of this study is to evaluate the effect of transdermal nitroglycerin on intrathecal dexmedetomidine as additive, on postoperative analgesia after abdominal hysterectomy. Materials and Methods: Totally 140 patients of the American Society of Anesthesiologists Grade I or II, posted for abdominal hysterectomy under spinal anesthesia, were randomized to four groups using computer-generated random number list. Group B received 3 ml of 0.5% hyperbaric bupivacaine with 0.5 ml normal saline and placebo patch, Group BN received 3 ml of 0.5% hyperbaric bupivacaine with 0.5 ml NS and transdermal nitroglycerin (t-NTG, Group BD received 3 ml of 0.5% hyperbaric bupivacaine with 5 mcg (0.5 ml dexmedetomidine and placebo patch and Group BDN received 3 ml of 0.5% hyperbaric bupivacaine with 5 μg (0.5 ml dexmedetomidine and t-NTG patch. Outcomes measured include the total duration of analgesia, onset, and duration of sensory and motor block and any adverse effects. Results: The total duration of analgesia was longest in Group BDN (349.9 ± 40.6 min. It was significantly longer than Group BD (252.3 ± 34.0 min and Group B and BN (130.5 ± 18.8, 138.3 ± 19.2 min. Time taken for two segment regression was comparable in Group B (79.9 ± 14.4 min and Group BN (87.1 ± 22.6 min, but it was significantly longer in Group BD (122.5 ± 17.2 min and Group BDN (136.4 ± 25.5 min. There was no significant difference in other variables between the groups. Conclusion: Transdermal nitroglycerine itself does not exhibit any analgesic potential of its own but, it enhances the analgesic potential of intrathecal dexmedetomidine.

  11. Implants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study

    Directory of Open Access Journals (Sweden)

    GVA Stadelmann

    2008-07-01

    Full Text Available It is a clinical challenge to obtain a sufficient orthopaedic implant fixation in weak osteoporotic bone. When the primary implant fixation is poor, micromotions occur at the bone-implant interface, activating osteoclasts, which leads to implant loosening. Bisphosphonate can be used to prevent the osteoclastic response, but when administered systemically its bioavailability is low and the time it takes for the drug to reach the periprosthetic bone may be a limiting factor. Recent data has shown that delivering bisphosphonate locally from the implant surface could be an interesting solution. Local bisphosphonate delivery increased periprosthetic bone density, which leads to a stronger implant fixation, as demonstrated in rats by the increased implant pullout force. The aim of the present study was to verify the positive effect on periprosthetic bone remodelling of local bisphosphonate delivery in an osteoporotic sheep model. Four implants coated with zoledronate and two control implants were inserted in the femoral condyle of ovariectomized sheep for 4 weeks. The bone at the implant surface was 50% higher in the zoledronate-group compared to control group. This effect was significant up to a distance of 400µm from the implant surface. The presented results are similar to what was observed in the osteoporotic rat model, which suggest that the concept of releasing zoledronate locally from the implant to increase the implant fixation is not species specific. The results of this trial study support the claim that local zoledronate could increase the fixation of an implant in weak bone.

  12. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  13. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Histology of a dental implant with a platform switched implant-abutment connection

    Directory of Open Access Journals (Sweden)

    Vittoria Perrotti

    2011-10-01

    Full Text Available Background: Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. Materials and methods: A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. Results: The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.

  15. Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.

    Science.gov (United States)

    Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T

    2016-01-01

    Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.

  16. Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation

    Directory of Open Access Journals (Sweden)

    Peter Mallon

    2013-07-01

    Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.

  17. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  18. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  19. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  20. One-stage explant-implant procedure of exposed porous orbital implants

    DEFF Research Database (Denmark)

    Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik

    2011-01-01

    Purpose:  To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods:  Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....

  1. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  2. Neostigmine interactions with non steroidal anti-inflammatory drugs.

    Science.gov (United States)

    Miranda, Hugo F; Sierralta, Fernando; Pinardi, Gianni

    2002-04-01

    1. The common mechanism of action of non-steroidal anti-inflammatory drugs (NSAIDs) is the inhibition of the enzyme cyclo-oxygenase (COX), however, this inhibition is not enough to completely account for the efficacy of these agents in several models of acute pain. 2. It has been demonstrated that cholinergic agents can induce antinociception, but the nature of the interaction between these agents and NSAIDs drugs has not been studied. The present work evaluates, by isobolographic analysis, the interactions between the cholinergic indirect agonist neostigmine (NEO) and NSAIDs drugs, using a chemical algesiometric test. 3. Intraperitoneal (i.p.) or intrathecal (i.t.) administration of NEO and of the different NSAIDs produced dose-dependent antinociception in the acetic acid writhing test of the mouse. 4. The i.p. or i.t. co-administration of fixed ratios of ED(50) fractions of NSAIDs and NEO, resulted to be synergistic or supra-additive for the combinations ketoprofen (KETO) and NEO, paracetamol (PARA) and NEO) and diclofenac (DICLO) and NEO administered i.p. However, the same combinations administered i.t. were only additive. In addition, the combinations meloxicam (MELO) and NEO and piroxicam (PIRO) and NEO, administered either i.p. or i.t., were additive. 5. The results suggest that the co-administration of NEO with some NSAIDs (e.g. KETO, PARA or DICLO) resulted in a synergistic interaction, which may provide evidence of supraspinal antinociception modulation by the increased acetylcholine concentration in the synaptic cleft of cholinergic interneurons. The interaction obtained between neostigmine and the NSAIDs could carry important clinical implications.

  3. Similarities and differences in coatings for magnesium-based stents and orthopaedic implants

    Directory of Open Access Journals (Sweden)

    Jun Ma

    2014-07-01

    Full Text Available Magnesium (Mg-based biodegradable materials are promising candidates for the new generation of implantable medical devices, particularly cardiovascular stents and orthopaedic implants. Mg-based cardiovascular stents represent the most innovative stent technology to date. However, these products still do not fully meet clinical requirements with regards to fast degradation rates, late restenosis, and thrombosis. Thus various surface coatings have been introduced to protect Mg-based stents from rapid corrosion and to improve biocompatibility. Similarly, different coatings have been used for orthopaedic implants, e.g., plates and pins for bone fracture fixation or as an interference screw for tendon-bone or ligament-bone insertion, to improve biocompatibility and corrosion resistance. Metal coatings, nanoporous inorganic coatings and permanent polymers have been proved to enhance corrosion resistance; however, inflammation and foreign body reactions have also been reported. By contrast, biodegradable polymers are more biocompatible in general and are favoured over permanent materials. Drugs are also loaded with biodegradable polymers to improve their performance. The key similarities and differences in coatings for Mg-based stents and orthopaedic implants are summarized.

  4. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  5. Gallium and silicon synergistically promote osseointegration of dental implant in patients with osteoporosis.

    Science.gov (United States)

    Liu, Jinsong; Wu, Zuosu; He, Hongli; Cai, Kaiyong; Zhang, Hualin; Xu, Lihua

    2017-06-01

    Over the last few decades, a wide variety of dental implants have been successfully placed in jaw bones to restore tooth function. But major challenges still remain in patients with osteoporosis involving compromised osseointegration, and the therapeutic methods is far from optimism. Gallium can directly inhibit bone osteolysis, prevent bone calcium release and augment bone mass, which makes Ga unique among the potential antiresorptive drugs. Silicon, as an indispensable modulator in bone formation, presents its bone anabolic effects, while reduces, at least doesn't increase, bone resorption. We hypothesize that the combination of bone anabolic effects of Si and antiresorptive effects of Ga will result in synergistic effects on the improvement of osteointegration under osteoporotic condition. In our strategy, in order to maximize the efficacy while minimize the side effects of ions, a novel titania mesoporous layer fabricated by electrochemical anodization on the surface of titanium implant will be employed as a promising local drug delivery system. The synergistic effects of Ga and Si on improving osseointegration will be verified by animal experiments, and be furthered by clinical trials. Our hypothesis could help to create an option to improve success rate of dental implants in osteoporotic patients. Copyright © 2017. Published by Elsevier Ltd.

  6. Pharmacological management of spasticity in multiple sclerosis

    DEFF Research Database (Denmark)

    Otero-Romero, Susana; Sastre-Garriga, Jaume; Comi, Giancarlo

    2016-01-01

    Background and objectives: Treatment of spasticity poses a major challenge given the complex clinical presentation and variable efficacy and safety profiles of available drugs. We present a systematic review of the pharmacological treatment of spasticity in multiple sclerosis (MS) patients. Methods...... improvement is seen with the previous drugs. Nabiximols has a positive effect when used as add-on therapy in patients with poor response and/or tolerance to first-line oral treatments. Despite limited evidence, intrathecal baclofen and intrathecal phenol show a positive effect in severe spasticity...... and suboptimal response to oral drugs. Conclusion: The available studies on spasticity treatment offer some insight to guide clinical practice but are of variable methodological quality. Large, well-designed trials are needed to confirm the effectiveness of antispasticity agents and to produce evidence...

  7. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  8. Comparison of central nervous system prophylaxis with cranial radiation and intrathecal methotrexate versus intrathecal methotrexate alone in acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Muriel, F.S.; Svarch, E.; Pavlovsky, S.; Eppinger-Helft, M.; Braier, J.; Vergara, B.; Garay, G.; Kvicala, R.; Divito, J.M.; Failace, R.

    1983-08-01

    In acute lymphoblastic leukemia, central nervous system prophylaxis with irradiation plus intrathecal methotrexate (i.t. MTX) reduces the incidence of CNS relapse to 7%-15%. However, increased evidence of CNS delayed toxicity was recognized mainly in children as CT scan abnormalities and neuropsychologic alterations. Two questions were analyzed: (1) Will further doses of i.t. methotraxate and dexamethasone (i.t. MTX-DMT) decrease the incidence of CNS relapse. (2) Is i.t. MTX-DMT given during induction and maintenance as effective as cranium irradiation plus i.t. MTX-DMT. Incidence of primary CNS relapse in i.t. MTX-DMT-treated patients with a WBC count < 50,000 and in the untreated group was 11%. In patients with a WBC count > 50,000, it was 16% in the treated group and 19% in the control group. These patients were compared with patients which had received 3 doses of i.t. MTX-DMT alone during induction, 3 doses weekly during the first month of remission, and quarterly thereafter. The incidence of leukemia at 60 mo in patients with a WBC count < 50,000 was 20% in the irradiated group and 32% in the group with i.t. MTX-DMT alone. The relapse-free survival at 60 mo was 26% and 41%, respectively, (p < 0.0005). The incidence in patients with a WBC count > 50,000 at 48 mo was 28% and 42% in the irradiated and nonirradiated group respectively. Complete remission remained at 15% and 16% respectively of patients disease-free at 48 mo. We conclude that (A) after cranial irradiation plus i.t. MTX-DMT X 5, the use of additional doses of i.t. MTX-DMT is not of further benefit in preventing CNS relapse; (B) use of i.t. MTX-DMT alone compares with cranial irradiation plus i.t. MTX-DMT in incidence of CNS relapse; and (C) relapse-free survival and survival in patients with a WBC count < 50.000 were significantly longer in those without cranial irradiation.

  9. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  10. The use of magnetite nanoparticles for implant-assisted magnetic drug targeting in thrombolytic therapy.

    Science.gov (United States)

    Kempe, Maria; Kempe, Henrik; Snowball, Ian; Wallén, Rita; Arza, Carlos Rodriguez; Götberg, Matthias; Olsson, Tommy

    2010-12-01

    Implant-assisted targeting of magnetic particles under the influence of an external magnetic field has previously been verified through mathematical modeling, in vitro studies, and in vivo studies on rat carotid arteries as a feasible method for localized drug delivery. The present study focuses on the development of nanoparticles for the treatment of in-stent thrombosis. Magnetic nanoparticles in the size-range 10-30 nm were synthesized in a one-pot procedure by precipitation of ferrous hydroxide followed by oxidation to magnetite. The nanoparticles were silanized with tetraethyl orthosilicate in the presence of triethylene glycol and/or polyethylene glycol. The surface coated magnetite nanoparticles were activated with either N-hydroxysulfosuccinimide or tresyl chloride for covalent immobilization of tissue plasminogen activator (tPA). Hysteresis loops showed saturation magnetizations of 55.8, 44.1, and 43.0 emu/g for the naked nanoparticles, the surface coated nanoparticles, and the tPA-nanoparticle conjugates, respectively. The hemolytic activity of the nanoparticles in blood was negligible. An initial in vivo biocompatibility test in pig, carried out by intravascular injection of the nanoparticles in a stented brachial artery, showed no short-term adverse effects. In vitro evaluation in a flow-through model proved that the nanoparticles were captured efficiently to the surface of a ferromagnetic coiled wire at the fluid velocities typical for human arteries. A preliminary test of the tPA-nanoparticle conjugates in a pig model suggested that the conjugates may be used for treatment of in-stent thrombosis in coronary arteries. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Actuarial risk of isolated CNS involvement in Ewing's sarcoma following prophylactic cranial irradiation and intrathecal methotrexate

    International Nuclear Information System (INIS)

    Trigg, M.E.; Makuch, R.; Glaubiger, D.

    1985-01-01

    Records of 154 patients with Ewing's sarcoma treated at the National Cancer Institute were reviewed to assess the incidence and risk of developing isolated central nervous system (CNS) Ewing's sarcoma. Sixty-two of the 154 patients had received CNS irradiation and intrathecal (i.t.) methotrexate as part of their initial therapy to prevent the occurrence of isolated CNS Ewing's sarcoma. The risk of developing isolate CNS Ewing's sarcoma was greatest within the first two years after diagnosis and was approximately 10%. The overall risk of CNS recurrence in the group of patients receiving DNS treatment was similar to the group receiving no therapy directed to the CNS. The occurrence of isolated CNS involvement was not prevented by the use of CNS irradiation and i.t. methotrexate. Because of a lack of efficacy to the CNS irradiation regimen, current treatment regimens do not include therapy directed to CNS

  12. Non-invasive in vivo evaluation of in situ forming PLGA implants by benchtop magnetic resonance imaging (BT-MRI) and EPR spectroscopy.

    Science.gov (United States)

    Kempe, Sabine; Metz, Hendrik; Pereira, Priscila G C; Mäder, Karsten

    2010-01-01

    In the present study, we used benchtop magnetic resonance imaging (BT-MRI) for non-invasive and continuous in vivo studies of in situ forming poly(lactide-co-glycolide) (PLGA) implants without the use of contrast agents. Polyethylene glycol (PEG) 400 was used as an alternative solvent to the clinically used NMP. In addition to BT-MRI, we applied electron paramagnetic resonance (EPR) spectroscopy to characterize implant formation and drug delivery processes in vitro and in vivo. We were able to follow key processes of implant formation by EPR and MRI. Because EPR spectra are sensitive to polarity and mobility, we were able to follow the kinetics of the solvent/non-solvent exchange and the PLGA precipitation. Due to the high water affinity of PEG 400, we observed a transient accumulation of water in the implant neighbourhood. Furthermore, we detected the encapsulation by BT-MRI of the implant as a response of the biological system to the polymer, followed by degradation over a period of two months. We could show that MRI in general has the potential to get new insights in the in vivo fate of in situ forming implants. The study also clearly shows that BT-MRI is a new viable and much less expensive alternative for superconducting MRI machines to monitor drug delivery processes in vivo in small mammals. Copyright 2009 Elsevier B.V. All rights reserved.

  13. Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent

    2017-01-01

    weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...

  14. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  15. Intrathecal application of the nimodipine slow-release microparticle system eg-1962 for prevention of delayed cerebral ischemia and improvement of outcome after aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Etminan, Nima; Macdonald, R Loch; Davis, Cara; Burton, Kevin; Steiger, Hans-Jakob; Hänggi, Daniel

    2015-01-01

    The effective reduction of delayed cerebral ischemia (DCI), a main contributor for poor outcome following aneurysmal subarachnoid hemorrhage (SAH), remains challenging. Previous clinical trials on systemic pharmaceutical treatment of SAH mostly failed to improve outcome, probably because of insensitive pharmaceutical targets and outcome measures, small sample size, insufficient subarachnoid drug concentrations and also detrimental, systemic effects of the experimental treatment per se. Interestingly, in studies that are more recent, intrathecal administration of nicardipine pellets following surgical aneurysm repair was suggested to have a beneficial effect on DCI and neurological outcome. However, this positive effect remained restricted to patients who were treated surgically for a ruptured aneurysm. Because of the favorable results of the preclinical data on DCI and neurological outcome in the absence of neurotoxicity or systemic side effects, we are initiating clinical trials. The PROMISE (Prolonged Release nimOdipine MIcro particles after Subarachnoid hemorrhage) trial is designed as an unblinded, nonrandomized, single-center, single-dose, dose-escalation safety and tolerability phase 1 study in patients surgically treated for aSAH and will investigate the effect of intracisternal EG-1962 administration. The NEWTON (Nimodipine microparticles to Enhance recovery While reducing TOxicity after subarachNoid hemorrhage) trial is a phase 1/2a multicenter, controlled, randomized, open-label, dose-escalation, safety, tolerability, and pharmacokinetic study comparing EG-1962 and nimodipine in patients with aneurysmal SAH.

  16. Surface characterization and biodegradation behavior of magnesium implanted poly(L-lactide/caprolactone) films

    Science.gov (United States)

    Sokullu, Emel; Ersoy, Fulya; Yalçın, Eyyup; Öztarhan, Ahmet

    2017-11-01

    Biopolymers are great source for medical applications such as drug delivery, wound patch, artificial tissue studies etc., food packaging, cosmetic applications etc. due to their biocompatibility and biodegradability. Particularly, the biodegradation ability of a biomaterial makes it even advantageous for the applications. The more tunable the biodegradation rate the more desired the biopolymers. There are many ways to tune degradation rate including surface modification. In this study ion implantation method applied to biopolymer surface to determine its effect on biodegradation rate. In this study, surface modification of poly(L-lactide/caprolactone) copolymer film is practiced via Mg-ion-implantation using a MEVVA ion source. Mg ions were implanted at a fluence of 1 × 1015 ions/cm2 and ion energy of 30 keV. Surface characterization of Mg-ion-implanted samples is examined using Atomic Force Microscopy, Raman spectroscopy, contact angle measurement and FT-IR Spectroscopy. These analyses showed that the surface become more hydrophilic and rougher after the ion implantation process which is advantageous for cell attachment on medical studies. The in vitro enzymatic degradation of Mg-implanted samples was investigated in Lipase PS containing enzyme solution. Enzymatic degradation rate was examined by mass loss calculation and it is shown that Mg-implanted samples lost more than 30% of their weight while control samples lost around 20% of their weight at the end of the 16 weeks. The evaluation of the results confirmed that Mg-ion-implantation on poly(L-lactide/caprolactone) films make the surface rougher and more hydrophilic and changes the organic structure on the surface. On the other hand, ion implantation has increased the biodegradation rate.

  17. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  18. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  19. A wireless actuating drug delivery system

    International Nuclear Information System (INIS)

    Jo, Won-Jun; Baek, Seung-Ki; Park, Jung-Hwan

    2015-01-01

    A wireless actuating drug delivery system was devised. The system is based on induction heating for drug delivery. In this study, thermally generated nitrogen gas produced by induction heating of azobisisobutyronitrile (AIBN) was utilized for pressure-driven release of the drug. The delivery device consists of an actuator chamber, a drug reservoir, and a microchannel. A semicircular copper disc (5 and 6 mm in diameter and 100 µm thick), and thermal conductive tape were integrated as the heating element in the actuator chamber. The final device was 2.7 mm thick. 28 µl of drug solution were placed in the reservoir and the device released the drug quickly at the rate of 6 µl s −1 by induction heating at 160 µT of magnetic intensity. The entire drug solution was released and dispersed after subcutaneous implantation under identical experimental condition. This study demonstrates that the device was simply prepared and drug delivery could be achieved by wireless actuation of a thin, pressure-driven actuator. (paper)

  20. A remotely operated drug delivery system with dose control

    KAUST Repository

    Yi, Ying; Kosel, Jü rgen

    2017-01-01

    include an effective actuation stimulus and a controllable dose release mechanism. This work focuses on remotely powering an implantable drug delivery system and providing a high degree of control over the released dose. This is accomplished by integration

  1. Imaging of common breast implants and implant-related complications: A pictorial essay

    OpenAIRE

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...

  2. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  3. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  4. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  5. Osmotically driven drug delivery through remote-controlled magnetic nanocomposite membranes

    KAUST Repository

    Zaher, A.

    2015-09-29

    Implantable drug delivery systems can provide long-term reliability, controllability, and biocompatibility, and have been used in many applications, including cancer pain and non-malignant pain treatment. However, many of the available systems are limited to zero-order, inconsistent, or single burst event drug release. To address these limitations, we demonstrate prototypes of a remotely operated drug delivery device that offers controllability of drug release profiles, using osmotic pumping as a pressure source and magnetically triggered membranes as switchable on-demand valves. The membranes are made of either ethyl cellulose, or the proposed stronger cellulose acetate polymer, mixed with thermosensitive poly(N-isopropylacrylamide) hydrogel and superparamagnetic iron oxide particles. The prototype devices\\' drug diffusion rates are on the order of 0.5–2 μg/h for higher release rate designs, and 12–40 ng/h for lower release rates, with maximum release ratios of 4.2 and 3.2, respectively. The devices exhibit increased drug delivery rates with higher osmotic pumping rates or with magnetically increased membrane porosity. Furthermore, by vapor deposition of a cyanoacrylate layer, a drastic reduction of the drug delivery rate from micrograms down to tens of nanograms per hour is achieved. By utilizing magnetic membranes as the valve-control mechanism, triggered remotely by means of induction heating, the demonstrated drug delivery devices benefit from having the power source external to the system, eliminating the need for a battery. These designs multiply the potential approaches towards increasing the on-demand controllability and customizability of drug delivery profiles in the expanding field of implantable drug delivery systems, with the future possibility of remotely controlling the pressure source.

  6. Osmotically driven drug delivery through remote-controlled magnetic nanocomposite membranes

    KAUST Repository

    Zaher, Amir; Li, S.; Wolf, K. T.; Pirmoradi, F. N.; Yassine, Omar; Lin, L.; Khashab, Niveen M.; Kosel, Jü rgen

    2015-01-01

    Implantable drug delivery systems can provide long-term reliability, controllability, and biocompatibility, and have been used in many applications, including cancer pain and non-malignant pain treatment. However, many of the available systems are limited to zero-order, inconsistent, or single burst event drug release. To address these limitations, we demonstrate prototypes of a remotely operated drug delivery device that offers controllability of drug release profiles, using osmotic pumping as a pressure source and magnetically triggered membranes as switchable on-demand valves. The membranes are made of either ethyl cellulose, or the proposed stronger cellulose acetate polymer, mixed with thermosensitive poly(N-isopropylacrylamide) hydrogel and superparamagnetic iron oxide particles. The prototype devices' drug diffusion rates are on the order of 0.5–2 μg/h for higher release rate designs, and 12–40 ng/h for lower release rates, with maximum release ratios of 4.2 and 3.2, respectively. The devices exhibit increased drug delivery rates with higher osmotic pumping rates or with magnetically increased membrane porosity. Furthermore, by vapor deposition of a cyanoacrylate layer, a drastic reduction of the drug delivery rate from micrograms down to tens of nanograms per hour is achieved. By utilizing magnetic membranes as the valve-control mechanism, triggered remotely by means of induction heating, the demonstrated drug delivery devices benefit from having the power source external to the system, eliminating the need for a battery. These designs multiply the potential approaches towards increasing the on-demand controllability and customizability of drug delivery profiles in the expanding field of implantable drug delivery systems, with the future possibility of remotely controlling the pressure source.

  7. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  8. Recent progress on fabrication and drug delivery applications of nanostructured hydroxyapatite.

    Science.gov (United States)

    Mondal, Sudip; Dorozhkin, Sergy V; Pal, Umapada

    2018-07-01

    Through this brief review, we provide a comprehensive historical background of the development of nanostructured hydroxyapatite (nHAp), and its application potentials for controlled drug delivery, drug conjugation, and other biomedical treatments. Aspects associated with efficient utilization of hydroxyapatite (HAp) nanostructures such as their synthesis, interaction with drug molecules, and other concerns, which need to be resolved before they could be used as a potential drug carrier in body system, are discussed. This review focuses on the evolution of perceptions, practices, and accomplishments in providing improved delivery systems for drugs until date. The pioneering developments that have presaged today's fascinating state of the art drug delivery systems based on HAp and HAp-based composite nanostructures are also discussed. Special emphasis has been given to describe the application and effectiveness of modified HAp as drug carrier agent for different diseases such as bone-related disorders, carriers for antibiotics, anti-inflammatory, carcinogenic drugs, medical imaging, and protein delivery agents. As only a very few published works made comprehensive evaluation of HAp nanostructures for drug delivery applications, we try to cover the three major areas: concepts, practices and achievements, and applications, which have been consolidated and patented for their practical usage. The review covers a broad spectrum of nHAp and HAp modified inorganic drug carriers, emphasizing some of their specific aspects those needed to be considered for future drug delivery applications. This article is categorized under: Implantable Materials and Surgical Technologies > Nanomaterials and Implants Therapeutic Approaches and Drug Discovery > Nanomedicine for Respiratory Disease Nanotechnology Approaches to Biology > Cells at the Nanoscale. © 2017 Wiley Periodicals, Inc.

  9. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2018-01-01

    Full Text Available Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP, best-corrected visual acuity (BCVA, number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results. The mean follow-up duration was 11.7 ± 5.5 (range, 6–23 months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001 and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021. At the last visit, 11 eyes (84.4% had stable or improved VA and one eye (7.7% had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%. Postoperative complications were bleb encapsulation (69.2%, early hypotony (38.5%, hyphema (23.1%, decompression retinopathy (23.1%, choroidal detachment (15.4%, intraocular hemorrhage (7.7%, and late endophthalmitis (7.7%. One eye (7.7% was enucleated because of late endophthalmitis. Conclusions. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  10. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.

    Science.gov (United States)

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  11. Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis.

    Science.gov (United States)

    Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba

    2017-12-01

    The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.

  12. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  13. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    Science.gov (United States)

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p 3years to stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Study design of the influence of SErotonin inhibition on patients with RENAl impairment or diabetes undergoing drug-eluting stent implantation (SERENADE) study: A multicenter, open-label, prospective, randomized study.

    Science.gov (United States)

    Lee, Seung-Ah; Suh, Jung-Won; Park, Jin Joo; Yoon, Chang-Hwan; Cho, Young-Suk; Youn, Tae-Jin; Chae, In-Ho; Kim, Hyo-Soo; Kim, Sang-Hyun; Choi, Dong-Ju

    2015-07-01

    The rates of stent failure after percutaneous coronary intervention have decreased since the introduction of the drug-eluting stent (DES). However, chronic kidney disease (CKD) and diabetes mellitus (DM) remain strong clinical predictors of poor prognosis despite DES implantation. Sarpogrelate, a selective serotonin (5-hydroxytryptamine (HT)2a [5-HT2A]) receptor antagonist, has antiproliferative effects, reducing neointimal hyperplasia and smooth muscle cell proliferation, as well as potent antiplatelet action, inhibiting 5-HT-induced platelet aggregation. However, efficacy and safety data for sarpogrelate in patients with CKD or DM are limited. We aim to determine whether sarpogrelate has beneficial effects in patients with CDK or DM treated with DES implantation. The SERENADE trial is a multicenter, open-label, prospective, randomized study that will test the superiority of triple anti-platelet therapy (TAT; aspirin, clopidogrel, and sarpogrelate) to conventional dual antiplatelet therapy (DAT; aspirin and clopidogrel) in preventing late lumen loss 9 months after the index procedure in patients with CKD or DM. A total of 220 patients diagnosed with coronary artery disease with DM or CKD will be randomized to the TAT or DAT groups (1:1 ratio) after DES implantation. The primary endpoint is late lumen loss at 9 months assessed by quantitative coronary angiography. Secondary efficacy endpoints are composites of major adverse cardiovascular events including cardiac death, nonfatal myocardial infarction, and target lesion revascularization. Secondary safety endpoints are major bleeding events and hepatic or renal impairment. The SERENADE trial will provide insight on the efficacy of adjunctive therapy with sarpogrelate after DES implantation for patients with high-risk profiles such as CKD or DM. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov NCT02294643). Copyright © 2015. Published by Elsevier Inc.

  15. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  16. Lipid nanoparticles as drug/gene delivery systems to the retina.

    Science.gov (United States)

    del Pozo-Rodríguez, Ana; Delgado, Diego; Gascón, Alicia R; Solinís, Maria Ángeles

    2013-03-01

    This review highlights the application of lipid nanoparticles (Solid Lipid Nanoparticles, Nanostructured Lipid Carriers, or Lipid Drug Conjugates) as effective drug/gene delivery systems for retinal diseases. Most drug products for ocular disease treatment are marketed as eye drop formulations but, due to ocular barriers, the drug concentration in the retina hardly ever turns out to be effective. Up to this date, several delivery systems have been designed to deliver drugs to the retina. Drug delivery strategies may be classified into 3 groups: noninvasive techniques, implants, and colloidal carriers. The best known systems for drug delivery to the posterior eye are intravitreal implants; in fact, some of them are being clinically used. However, their long-term accumulation might impact the patient's vision. On the contrary, colloidal drug delivery systems (microparticles, liposomes, or nanoparticles) can be easily administered in a liquid form. Nanoparticular systems diffuse rapidly and are better internalized in ocular tissues than microparticles. In comparison with liposomes, nanoparticles have a higher loading capacity and are more stable in biological fluids and during storage. In addition, their capacity to adhere to the ocular surface and interact with the endothelium makes these drug delivery systems interesting as new therapeutic tools in ophthalmology. Within the group of nanoparticles, those composed of lipids (Solid Lipid Nanoparticles, Nanostructred Lipid Carriers, and Lipid Drug Conjugates) are more biocompatible, easy to produce at large scale, and they may be autoclaved or sterilized. The present review summarizes scientific results that evidence the potential application of lipid nanoparticles as drug delivery systems for the retina and also as nonviral vectors in gene therapy of retina disorders, although much more effort is still needed before these lipidic systems could be available in the market.

  17. Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I.

    Science.gov (United States)

    Yue, Lan; Falabella, Paulo; Christopher, Punita; Wuyyuru, Varalakshmi; Dorn, Jessy; Schor, Paulo; Greenberg, Robert J; Weiland, James D; Humayun, Mark S

    2015-12-01

    The Argus I implant is the first-generation epiretinal prosthesis approved for an investigational clinical trial by the United States Food and Drug Administration. Herein we report testing results obtained from a 10-year follow-up to study the physiologic effects of the bioelectronic visual implant after prolonged chronic electrical stimulation. Case report. One man, 55 years of age when enrolled in the study, underwent surgical implantation of the Argus I in June 2004, followed by periodic tests from July 2004 through June 2014, spanning a total of 10 years. The decade-long follow-up consisted of implant system performance tests, subject visual function evaluation, and implant-retina interface analysis. Changes in electrode impedance and perceptual threshold over the time course; subject's performance on visual function task, orientation, and mobility tests; and optical coherence tomography data, fundus imaging, and fluorescein angiography results for the assessment of subject's implant-retina physical interface. Electrically elicited phosphenes were present 10 years after implantation of an epiretinal stimulator. The test subject not only was able to perceive phosphenes, but also could perform visual tasks at rates well above chance. This decade-long follow-up report provides further support for the use of retinal prostheses as a long-lasting treatment for some types of blindness. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  19. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  20. Locally delivered ethyl-2,5-dihydroxybenzoate using 3D printed bone implant for promotion of bone regeneration in a osteoporotic animal model

    Directory of Open Access Journals (Sweden)

    B-J Kwon

    2018-01-01

    Full Text Available Osteoporosis is a disease characterized by low bone mass, most commonly caused by an increase in bone resorption that is not matched by sufficient bone formation. The most common complications of postmenopausal osteoporosis are bone-related defects and fractures. Fracture healing is a multifactorial bone regeneration process, influenced by both biological and mechanical factors related to age, osteoporosis and stability of the osteosynthesis. During the treatment of bone defects in osteoporotic conditions, imbalanced bone remodeling is the leading cause for implant failure. To overcome these problems, ethyl-2,5-dihydroxybenzoate (E-2,5-DHB, a drug that promotes bone formation and inhibits bone resorption, was used. E-2,5-DHB-incorporating titanium (Ti implants using poly(lactic-co-glycolic acid (PLGA coating for local delivery of E-2,5-DHB were developed and the effects on bone healing of femoral defects were evaluated in an osteoporotic model. The release of E-2,5-DHB resulted in decreased bone resorption and increased bone formation around the implant. Thus, it was confirmed that, in the osteoporotic model, bone healing was increased and implant fixation was enhanced. These results suggested that E-2,5-DHB-coated Ti implants have great potential as an ultimate local drug delivery system for bone tissue scaffolds.

  1. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  2. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  3. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  4. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  5. Hypothesis: Co-transfer of genuine embryos and implantation-promoting compounds via artificial containers improve endometrium receptivity.

    Science.gov (United States)

    Celik, Onder; Acet, Mustafa; Celik, Sudenaz; Sahin, Levent; Koc, Onder; Celik, Nilufer

    2017-06-01

    As with other organs endometrial functions are altered with the advancing age. Age related decrease in reproductive functions leads to decline in the number of oocytes retrieved and the synthesis of endometrial receptivity molecules. Despite the significant improvement in assisted reproductive technologies we do not have so many options to enhance endometrial receptivity. Due to lack of drugs having endometrium receptivity enhancement properties, oocyte donation seems to be the only solution for women with implantation failure. The euploid oocytes come from young and healthy donors may overcome age associated endometrial receptivity defect. Nevertheless, many reasons restrict us from using oocyte donation in women with implantation failure. We, therefore, hypothesized that by mimicking a young blastocyst's effect on endometrium, the transfer of genuine embryos and implantation-promoting compounds together might be the new treatment option for infertile women with recurrent implantation failure. Artificial beads, MI or GV oocytes, and empty zona can be used as a container for intrauterine replacement of implantation-promoting compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Metals for bone implants. Part 1. Powder metallurgy and implant rendering.

    Science.gov (United States)

    Andani, Mohsen Taheri; Shayesteh Moghaddam, Narges; Haberland, Christoph; Dean, David; Miller, Michael J; Elahinia, Mohammad

    2014-10-01

    New metal alloys and metal fabrication strategies are likely to benefit future skeletal implant strategies. These metals and fabrication strategies were looked at from the point of view of standard-of-care implants for the mandible. These implants are used as part of the treatment for segmental resection due to oropharyngeal cancer, injury or correction of deformity due to pathology or congenital defect. The focus of this two-part review is the issues associated with the failure of existing mandibular implants that are due to mismatched material properties. Potential directions for future research are also studied. To mitigate these issues, the use of low-stiffness metallic alloys has been highlighted. To this end, the development, processing and biocompatibility of superelastic NiTi as well as resorbable magnesium-based alloys are discussed. Additionally, engineered porosity is reviewed as it can be an effective way of matching the stiffness of an implant with the surrounding tissue. These porosities and the overall geometry of the implant can be optimized for strain transduction and with a tailored stiffness profile. Rendering patient-specific, site-specific, morphology-specific and function-specific implants can now be achieved using these and other metals with bone-like material properties by additive manufacturing. The biocompatibility of implants prepared from superelastic and resorbable alloys is also reviewed. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Titania nanotubes with adjustable dimensions for drug reservoir sites and enhanced cell adhesion.

    Science.gov (United States)

    Çalışkan, Nazlı; Bayram, Cem; Erdal, Ebru; Karahaliloğlu, Zeynep; Denkbaş, Emir Baki

    2014-02-01

    This study aims to generate a bactericidal agent releasing surface via nanotube layer on titanium metal and to investigate how aspect ratio of nanotubes affects drug elution time and cell proliferation. Titania nanotube layers were generated on metal surfaces by anodic oxidation at various voltage and time parameters. Gentamicin loading was carried out via simple pipetting and the samples were tested against S. aureus for the efficacy of the applied modification. Drug releasing time and cell proliferation were also tested in vitro. Titania nanotube layers with varying diameters and lengths were prepared after anodization and anodizing duration was found as the most effective parameter for amount of loaded drug and drug releasing time. Drug elution lasted up to 4 days after anodizing for 80 min of the samples, whereas release completed in 24 h when the samples were anodized for 20 min. All processed samples had bactericidal properties against S. aureus organism except unmodified titanium, which was also subjected to drug incorporation step. The anodization also enhanced water wettability and cell adhesion results. Anodic oxidation is an effective surface modification to enhance tissue-implant interactions and also resultant titania layer can act as a drug reservoir for the release of bactericidal agents. The use of implants as local drug eluting devices is promising but further in vivo testing is required. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Novel implant design improves implant survival in multirooted extraction sites: a preclinical pilot study.

    Science.gov (United States)

    Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar

    2014-10-01

    The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.

  9. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  10. Structure of ion-implanted ceramics

    International Nuclear Information System (INIS)

    Naramoto, Hiroshi

    1983-01-01

    The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)

  11. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  12. THE EFFECTS OF INTRATHECAL NEOSTIGMINE ADDED TO BUPIVACAINE ON POSTOPERATIVE ANALGESIC REQUIREMENT IN PATIENTS UNDERGOING LOWER LIMB ORTHOPEDIC SURGERY.

    Science.gov (United States)

    Kayalha, Hamid; Mousavi, Zinat; Sadat Barikani, Ameneh; Yaghoobi, Siamak; Khezri, Marzieh Beigom

    2015-06-01

    Several additives have been suggested to enhance analgesic effect of local anesthetic agents to decrease the adverse effects of them and increase the degree of satisfaction. We designed this randomized double-blind controlled study to evaluate the analgesic efficacy of the neostigmine added to bupivacaine using spinal anesthesia in patients undergoing lower limb orthopedic surgery. Sixty patients 18-80 yr old American Society of Anesthesiologists (ASA) physical status I or II, scheduled for femur surgery under spinal anesthesia, were recruited in a prospective, double-blinded, randomized way. The patients were randomly allocated to one of two groups of 30 each. The neostigmine group (group N) received bupivacaine 20 mg combined with 25 µg neostigmine, and the placebo group (group C) received bupivacaine 20 mg combined with 0.5ml distilled water (intrathecally) 5 minutes prior to surgery. The time to the first analgesic request, analgesic requirement in the first 12 hours after surgery, the duration of sensory and motor blockade, the incidence of adverse effects such as nausea,vomiting,hypotension, ephedrine requirements, bradycardia, and hypoxemia were recorded. Patients receiving neostigmine had a significantly prolonged duration of motor block (C95% CI 30.27 to 87.65; P < 0.001) and sensory block (C95% CI 101.04 to 224.64; P < 0.001) compared to the control group. The difference of the mean time to the first analgesic request was also significantly longer in neostigmine group (C95% CI 83.139 to 208.526; P < 0.001). The total analgesic consumption during the first 12 hours after surgery was devoid of any significant difference between groups N and C (p = 0.41).The two groups were not significantly different in terms of intraoperative and postoperative side effects. Intrathecal neostigmine 25 µg with bupivacaine caused a prolonged time to the first analgesic request and its use was not associated with any side effects.

  13. Microfabrication for Drug Delivery

    Science.gov (United States)

    Koch, Brendan; Rubino, Ilaria; Quan, Fu-Shi; Yoo, Bongyoung; Choi, Hyo-Jick

    2016-01-01

    This review is devoted to discussing the application of microfabrication technologies to target challenges encountered in life processes by the development of drug delivery systems. Recently, microfabrication has been largely applied to solve health and pharmaceutical science issues. In particular, fabrication methods along with compatible materials have been successfully designed to produce multifunctional, highly effective drug delivery systems. Microfabrication offers unique tools that can tackle problems in this field, such as ease of mass production with high quality control and low cost, complexity of architecture design and a broad range of materials. Presented is an overview of silicon- and polymer-based fabrication methods that are key in the production of microfabricated drug delivery systems. Moreover, the efforts focused on studying the biocompatibility of materials used in microfabrication are analyzed. Finally, this review discusses representative ways microfabrication has been employed to develop systems delivering drugs through the transdermal and oral route, and to improve drug eluting implants. Additionally, microfabricated vaccine delivery systems are presented due to the great impact they can have in obtaining a cold chain-free vaccine, with long-term stability. Microfabrication will continue to offer new, alternative solutions for the development of smart, advanced drug delivery systems. PMID:28773770

  14. Improvement of renal function after human umbilical cord mesenchymal stem cell treatment on chronic renal failure and thoracic spinal cord entrapment: a case report.

    Science.gov (United States)

    Rahyussalim, Ahmad Jabir; Saleh, Ifran; Kurniawati, Tri; Lutfi, Andi Praja Wira Yudha

    2017-11-30

    Chronic renal failure is an important clinical problem with significant socioeconomic impact worldwide. Thoracic spinal cord entrapment induced by a metabolic yield deposit in patients with renal failure results in intrusion of nervous tissue and consequently loss of motor and sensory function. Human umbilical cord mesenchymal stem cells are immune naïve and they are able to differentiate into other phenotypes, including the neural lineage. Over the past decade, advances in the field of regenerative medicine allowed development of cell therapies suitable for kidney repair. Mesenchymal stem cell studies in animal models of chronic renal failure have uncovered a unique potential of these cells for improving function and regenerating the damaged kidney. We report a case of a 62-year-old ethnic Indonesian woman previously diagnosed as having thoracic spinal cord entrapment with paraplegic condition and chronic renal failure on hemodialysis. She had diabetes mellitus that affected her kidneys and had chronic renal failure for 2 years, with creatinine level of 11 mg/dl, and no urinating since then. She was treated with human umbilical cord mesenchymal stem cell implantation protocol. This protocol consists of implantation of 16 million human umbilical cord mesenchymal stem cells intrathecally and 16 million human umbilical cord mesenchymal stem cells intravenously. Three weeks after first intrathecal and intravenous implantation she could move her toes and her kidney improved. Her creatinine level decreased to 9 mg/dl. Now after 8 months she can raise her legs and her creatinine level is 2 mg/dl with normal urinating. Human umbilical cord mesenchymal stem cell implantations led to significant improvement for spinal cord entrapment and kidney failure. The major histocompatibility in allogeneic implantation is an important issue to be addressed in the future.

  15. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  16. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  17. Electromagnetic interference of mobile phones with electronic implants

    International Nuclear Information System (INIS)

    Kainz, W.

    2000-03-01

    Chapter 1:Interference matrix: The objective of Chapter 1 was to give an overview of the implants used at present and their electromagnetic compatibility (EMC). The evaluation of the available literature provides an estimate of the probability of electronic implants being influenced by various interference sources. A literature search at the AKH (Allgemeines Krankenhaus) in Vienna and at the Technical University of Vienna in the FIZ (Fach-Informations-Zentrum) -Biomedizinische Technik, Medline, Pascal Biomed, CC Search und Embase databases yielded 236 relevant publications. At present 12 different implants are used: pacemaker, defibrillator, cochlear and brain-stem implants, neurostimulators, spinal-cord stimulators, spinal-fusion stimulators, telemetry systems, artificial hearts, drug-delivery systems, neurological pulse generators, visual prosthetics and implantable patient chips. The frequency with which they are used and the EMC on exposure to the various interference sources was summarized. Publications on EMC were found only for the first six implant types and only for 30% of the possible combinations of implant type and interference source. Based on the number of the implants examined, the probability of interference was calculated and summarized in the interference matrix. Chapter 2:Measurements on the phantom: No publication on the electromagnetic compatibility of neurological pulse generators (NPG) could be found. This implant has been used increasingly in the last few years to treat Parkinson's disease. A phantom was built to examine this implant at 900 MHz. The electromagnetic compatibility was measured by exposing the NPG to the fields of ten different 900 MHz GSM mobile phones. Every mobile phone was tested in three different positions relative to the phantom, with four electrode configurations and four stimulation parameters. No interference was found even at a maximum transmit power of 2 watts. Further tests with half-wave dipoles and increased

  18. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    Science.gov (United States)

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  19. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  20. Comparison of Reconstructive Outcomes in Breast Cancer Patients With Preexisting Subpectoral Implants: Implant-Sparing Mastectomy With Delayed Implant Exchange Versus Immediate Tissue Expander Reconstruction.

    Science.gov (United States)

    Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz

    2016-06-01

    Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.