WorldWideScience

Sample records for implanted aisi type

  1. Corrosion behaviour of nitrogen ion implanted AISI type 304L stainless steel in nitric acid medium

    Energy Technology Data Exchange (ETDEWEB)

    Padhy, N.; Ningshen, S. [Corrosion Science and Technology Division, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Panigrahi, B.K. [Material Science Division, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Kamachi Mudali, U. [Corrosion Science and Technology Division, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India)], E-mail: kamachi@igcar.gov.in

    2010-01-15

    The effects of nitrogen ion implantation on corrosion behaviour of 304L stainless steel in 1 N HNO{sub 3} medium were investigated using surface analytical and electrochemical techniques. Nitrogen ion was implanted at 70 keV in the dose range of 1 x 10{sup 15}, 1 x 10{sup 16}, 1 x 10{sup 17} and 2.5 x 10{sup 17} N{sup +}/cm{sup 2}, respectively. Grazing incidence X-ray diffraction results for unimplanted and up to dose of 1 x 10{sup 16} N{sup +}/cm{sup 2} showed co-existence of {gamma}-Fe and {alpha}'-Fe and, at higher doses (1 x 10{sup 17} and 2.5 x 10{sup 17}) preferential formation of chromium nitride was observed. X-ray photoelectron spectroscopy investigation confirmed the formation of chromium nitride at higher doses. Electrochemical corrosion investigation revealed nobler open circuit potential, decrease in corrosion current densities, passive current densities and increase in polarization resistance with increase in dose rate. Surface morphology analysis after polarization study using atomic force microscope showed grain boundary dissolution for unimplanted specimens and resistance to surface dissolution with increase in dose rate for implanted specimens.

  2. EFFECTS OF COPPER ION IMPLANTATION ON ANTIBACTERIAL ACTIVITY OF AISI420 STAINLESS STEEL

    Institute of Scientific and Technical Information of China (English)

    Z.G. Dan; H.W. Ni; B.F. Xu; J. Xiong; P. Y. Xiong

    2005-01-01

    Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2.0×1017ions .cm-2. The saturation dose of Cu implantation in AISI420 SS and Cu surface concentration were calculated at the energy of 100keV. The effect of dose on the antibacterial activity was analyzed. Results of antibacterial test show that the saturation dose is the optimum implantation dose for best antibacterial activity, which is above 99% against both Escherichia coli and Staphylococcus aureus. Novel phases such as Fe4Cu3 and Cu9.9Fe0.1 were found in the implanted layer by glancing angle X-ray diffraction (GXRD). The antibacterial activity of AISI420 SS attributes to Cu-contained phase.

  3. Corrosion behavior of low energy, high temperature nitrogen ion-implanted AISI 304 stainless steel

    Indian Academy of Sciences (India)

    M Ghorannevis; A Shokouhy; M M Larijani; S H Haji Hosseini; M Yari; A Anvari; M Gholipur Shahraki; A H Sari; M R Hantehzadeh

    2007-01-01

    This work presents the results of a low-energy nitrogen ion implantation of AISI 304 type stainless steel (SS) at a moderate temperature of about 500° C. The nitrogen ions are extracted from a Kauffman-type ion source at an energy of 30 keV, and ion current density of 100 A cm-2. Nitrogen ion concentration of 6 × 1017, 8 × 1017 and 1018 ions cm-2, were selected for our study. The X-ray diffraction results show the formation of CrN polycrystalline phase after nitrogen bombardment and a change of crystallinity due to the change in nitrogen ion concentration. The secondary ion mass spectrometry (SIMS) results show the formation of CrN phases too. Corrosion test has shown that corrosion resistance is enhanced by increasing nitrogen ion concentration.

  4. Stoichiometric titanium dioxide ion implantation in AISI 304 stainless steel for corrosion protection

    Science.gov (United States)

    Hartwig, A.; Decker, M.; Klein, O.; Karl, H.

    2015-12-01

    The aim of this study is to evaluate the applicability of highly chemically inert titanium dioxide synthesized by ion beam implantation for corrosion protection of AISI 304 stainless steel in sodium chloride solution. More specifically, the prevention of galvanic corrosion between carbon-fiber reinforced plastic (CFRP) and AISI 304 was investigated. Corrosion performance of TiO2 implanted AISI 304 - examined for different implantation and annealing parameters - is strongly influenced by implantation fluence. Experimental results show that a fluence of 5 × 1016 cm-2 (Ti+) and 1 × 1017 cm-2 (O+) is sufficient to prevent pitting corrosion significantly, while galvanic corrosion with CFRP can already be noticeably reduced by an implantation fluence of 5 × 1015 cm-2 (Ti+) and 1 × 1016 cm-2 (O+). Surface roughness, implantation energy and annealing at 200 °C and 400 °C show only little influence on the corrosion behavior. TEM analysis indicates the existence of stoichiometric TiO2 inside the steel matrix for medium fluences and the formation of a separated metal oxide layer for high fluences.

  5. Behavior of AISI SAE 1020 Steel Implanted by Titanium and Exposed to Bacteria Sulphate Deoxidizer

    Science.gov (United States)

    Niño, Ely Dannier V.; Garnica, Hernán; Dugar-Zhabon, Veleriy; Castillo, Genis

    2014-05-01

    A hybrid technology to treat solid surfaces with the pulse high voltage and electric arc discharges of low pressure with a three-dimensional ion implantation technique (3DII) is applied. This technology is used to protect AISI SAE 1020 steel against a microbiological corrosion. The titanium ion implanted steel samples (coupons) are subjected to a medium of bacteria sulphate deoxidizer (BSD) which are very typical of the hydrocarbon industry and are potentially harmful for structures when are in contact with petroleum and some of its derivatives. The used technology aims to find an effective hybrid procedure to minimize the harmful effects of bacteria on AISI SAE 1020 steel. The hybrid technology efficiency of superficial titanium implantation is estimated through the measurements of the point corrosion characteristics obtained after testing both the treated and non-treated coupons. The three-dimensional surface structures of the samples are reconstructed with help of a confocal microscope.

  6. Mössbauer studies on an AISI 1137 type steel

    Indian Academy of Sciences (India)

    E Güler; H Akta

    2006-06-01

    An AISI 1137 type medium carbon steel was studied by means of scanning electron microscopy and Mössbauer spectroscopy. This steel in as received state at room temperature was ferritic. Different heat treatments on related steel exhibited different microstructures such as pearlite and bainite. Also magnetism of these product phases was determined as 32.7 T and 32.6 T relatively where ferromagnetism of ferritic phase in as received state was 33.05 T. Mössbauer parameters such as isomer shifts and % volumes were also determined before and after transformations.

  7. 3DII implantation effect on corrosion properties of the AISI/SAE 1020 steel

    Energy Technology Data Exchange (ETDEWEB)

    Dulce M., H.J.; Rueda V., Alejandro [Universidad Francisco de Paula Santander, A.A. 1055, Cucuta (Colombia); Dougar-Jabon, Valeri [Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia)

    2005-08-01

    The three dimensional ion implantation technology (3DII) is one of the methods of improving the tribological characteristics and resistance to hydrogen embrittlement processes in metals. In this report, some results concerning the resistance effect of nitrogen ion implantation to oxidation of the sample, made of AISI/SAE 1020 steel, are given. The nitrogen ions were implanted in the discharge chamber of the JUPITER reactor. Both the treated and untreated samples were tested through potential-static measurements, which permitted to determine the corrosion current, the slopes that characterise the braking level of anode and cathode reactions. The polarization resistance near the corrosion potential is calculated. The results of the study encourage to consider the nitrogen ion implantation in high voltage and low pressure discharges as one of the methods of anticorrosive protection which do not change the geometric configuration of the treated steel pieces. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Nitrocarburizing of AISI-304 stainless steel using high-voltage plasma immersion ion implantation

    Science.gov (United States)

    Abd El-Rahman, A. M.; Mohamed, S. H.; Ahmed, M. R.; Richter, E.; Prokert, F.

    2009-05-01

    AISI-304 austenitic stainless steel has been nitrocarburized in N 2 and C 2H 2 ambient using high-voltage plasma immersion ion implantation (PIII) technology. The use of different PIII treatment times revealed important hints with respect to the microstructural, mechanical and corrosion properties of the nitrocarburized layer. Grazing incidence X-ray diffraction (GIXRD) shows the presence of nitride ( γN and CrN) and carbide ( γC and Fe 3C) phases. Glow discharge optical spectroscopy (GDOS) has been used to characterize the elemental depth profiles in which the thickness of the modified layers is derived. Dynamic microindentation method is used for the study of mechanical performance of the nitrocarburized layer as well as the untreated material. The microhardness has been increased to a maximum value of more than nine times compared to that of the untreated one. The corrosion performance is characterized by potentiodynamic polarization technique and was found to be treatment time dependent.

  9. Surface Modification by Nitrogen Plasma Immersion Ion Implantation on Austenitic AISI 304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    Miguel CASTRO-COLIN; William DURRER; Jorge ALPEZ; Enrique RAMIREZ-HOMS

    2016-01-01

    Surfaces of AISI 304 austenitic stainless steel plates nitrided by plasma immersion ion implantation (PIII) technology were studied by means of Auger electron spectroscopy (AES)and X-ray photoelectron spectroscopy (XPS)to determine the effect of the nitriding process on the surface and subjacent layers.Elemental compositions obtained by AES and XPS at varying depths indicate that the saturation of N is relatively constant as a function of depth,indicating the reliability of PIII technology for subsurface saturation.It is concluded that the concentrations of both Cr and O increase with depth,the subjacent oxide is driven by the Ar+ sputtering process used to access the lower layers,and then N is bound to Cr.

  10. The structural characterization of some biomaterials, type AISI 310, used in medicine

    Science.gov (United States)

    Minciuna, M. G.; Vizureanu, P.; Hanganu, C.; Achitei, D. C.; Popescu, D. C.; Focsaneanu, S. C.

    2016-06-01

    Orthopedics biomaterials are intended for implantation in the human body and substituted or help to repair of bones, cartilage or organ transplant, and tendons. At the end of the 20th century, the availability of materials for the manufacture implants used in medicine has been the same as for other industrial applications. The most used metals for manufacturing the orthopedics implants are: stainless steels, cobalt-chrome-molybdenum alloys, titanium and his alloys. The structural researches which are made in this paper, offer a complete analysis of AISI310 stainless steels, using: optical spectrometry, X-ray diffraction and scanning electronic microscopy.

  11. Tribological behavior of AISI302 austenitic stainless steel modified by elevated temperature nitrogen plasma immersion ion implantation

    Institute of Scientific and Technical Information of China (English)

    JIANG Shao-qun; MA Xin-xin; SUN Yue

    2004-01-01

    AISI302 stainless steel samples were modified by elevated temperature nitrogen plasma immersion ion implantation at temperature ranging from 330 ℃ to 450 ℃. The tribological behaviors of the implanted layers of the samples were investigated. The samples were characterized by Auger electron spectroscopy (AES), glancing angle X-ray diffraction (GXRD), and nanoindentation. The results show that the implantation temperature plays an important rule on the microstructure and surface properties of the implanted layers. The thickness of the modified layer implanted at 390 ℃ is about 9 μm. It is improved about two orders compared with that of the implanted at room temperature. The surface nanohardness and the wear resistance of elevated temperature implanted layers increase significantly, and the friction coefficient decreases obviously in comparison with the unimplanted one. These data suggests that the improvement results from the formation of new phases such as ε-(Fe, Cr, Ni)2+xN, or noncrystal phase.

  12. The adhesion of hot-filament CVD diamond films on AISI type 316 austenitic stainless steel

    NARCIS (Netherlands)

    Buijnsters, J.G.; Shankar, P.; Enckevort, W.J.P. van; Schermer, J.J.; Meulen, J.J. ter

    2004-01-01

    Steel ball indentation and scratch adhesion testing of hot filament chemical vapour deposited diamond films onto AISI type 316 austenitic stainless steel substrates using two different interlayer systems, namely chromium nitride and borided steel, have been investigated. In order to compare the adhe

  13. Nitrocarburizing of AISI-304 stainless steel using high-voltage plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Rahman, A.M. [Physics Department, Faculty of Science, Sohag University, 82524 Sohag (Egypt)], E-mail: ahmedphys96@hotmail.com; Mohamed, S.H.; Ahmed, M.R. [Physics Department, Faculty of Science, Sohag University, 82524 Sohag (Egypt); Richter, E.; Prokert, F. [Institut fuer Ionenstrahlphysik und Materialforschung, Forschungszentrum Dresden Rossendorf (Germany)

    2009-05-15

    AISI-304 austenitic stainless steel has been nitrocarburized in N{sub 2} and C{sub 2}H{sub 2} ambient using high-voltage plasma immersion ion implantation (PIII) technology. The use of different PIII treatment times revealed important hints with respect to the microstructural, mechanical and corrosion properties of the nitrocarburized layer. Grazing incidence X-ray diffraction (GIXRD) shows the presence of nitride ({gamma}{sub N} and CrN) and carbide ({gamma}{sub C} and Fe{sub 3}C) phases. Glow discharge optical spectroscopy (GDOS) has been used to characterize the elemental depth profiles in which the thickness of the modified layers is derived. Dynamic microindentation method is used for the study of mechanical performance of the nitrocarburized layer as well as the untreated material. The microhardness has been increased to a maximum value of more than nine times compared to that of the untreated one. The corrosion performance is characterized by potentiodynamic polarization technique and was found to be treatment time dependent.

  14. HTS SQUID application for measuring the magnetic properties of AISI type 316L(N) steel

    Energy Technology Data Exchange (ETDEWEB)

    Park, D.G. E-mail: dgpark@nanum.kaeri.re.kr; Kim, D.W.; Hong, J.H.; Timofeev, V.P.; Kim, C.G

    2000-06-02

    A portable RF HTS SQUID-based susceptometer was used for small-size magnetized sample testing in weak DC (up to 200 A/m) and AC (up to 4 A/m) magnetic fields. The system resolution for the magnetic moment is of the order of 1.6x10{sup -10} A m{sup 2}. The measured DC susceptibility of a tested sample of Gd{sub 88}La{sub 12} agrees well with the value obtained by using a commercial liquid helium susceptometer. The measured volume susceptibility of AISI type 316L(N) steel increases after fatigue due to the microcrack induced by cyclic stress.

  15. Influence of nitrogen alloying on hydrogen embrittlement in AISI 304-type stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Hannula, S.-P.; Hanninen, H.; Tahtinen, S.

    1984-12-01

    Hydrogen embrittlement of AISI 304-type austenitic stainless steels has been studied with special emphasis on the effects of the nitrogen content of the steels. Hydrogen charging was found to degrade the mechanical properties of all the steels studied, as measured by a tensile test. The fracture surfaces of hydrogen charged specimens were brittle cleavage-like whereas the uncharged specimens showed ductile, dimpled fracture. In sensitized materials transgranular cleavage mode of fracture was replaced by an intergranular mode of fracture and the losses of mechanical properties were higher. Nitrogen alloying decreased the hydrogen-induced losses of mechanical properties by increasing the stabilit of austenite. In sensitized steels the stability of austenite and nitrogen content were found to have only a minor effect on hydrogen embrittlement, except when sensitization had caused ..cap alpha..'-martensite transformation at the grain boundaries.

  16. Influence of nitrogen alloying on hydrogen embrittlement in AISI 304-type stainless steels

    Science.gov (United States)

    Hannula, Simo-Pekka; Hänninen, Hannu; Tähtinen, Seppo

    1984-12-01

    Hydrogen embrittlement of AISI 304-type austenitic stainless steels has been studied with special emphasis on the effects of the nitrogen content of the steels. Hydrogen charging was found to degrade the mechanical properties of all the steels studied, as measured by a tensile test. The fracture surfaces of hydrogen charged specimens were brittle cleavage-like whereas the uncharged specimens showed ductile, dimpled fracture. In sensitized materials transgranular cleavage mode of fracture was replaced by an intergranular mode of fracture and the losses of mechanical properties were higher. Nitrogen alloying decreased the hydrogen-induced losses of mechanical properties by increasing the stability of austenite. In sensitized steels the stability of austenite and nitrogen content were found to have only a minor effect on hydrogen embrittlement, except when sensitization had caused α'-martensite transformation at the grain boundaries.

  17. Enhancing the corrosion resistance of dentistry drills by plasma immersion nitrogen in implantation of AISI 434-based SS

    Energy Technology Data Exchange (ETDEWEB)

    Munoz C, A.E.; Lopez C, R.; Fuentes G, D.; Valencia A, R. [UAEM, Facultad de Quimica, Instituto Literario 100, Toluca (Mexico)]. e-mail: rlc@nuclear.inin.mx

    2007-07-01

    In order to enhance the resistance to the pitting corrosion due to asepsis processes and to avoid structural fractures in dentistry drills, a plasma immersion ion implantation (PIII) treatment using nitrogen has been performed. The selected drill samples, made of AISI 434 based stainless steel with a 0.670 mm diameter, were treated at a -1kV bias between 350 C and 450 C, this temperature being controlled by both a 20-50 {mu}s pulse width and a 200-1000 Hz repetition rate in the bias. The drills were analysed by cyclic potentiodynamic tests showing a good pitting corrosion resistance when treated at around 400 C, as follows from a resulting very low hysteresis loop. Yet, the resistance appears somehow diminished by the presence of sputtering when processed at temperatures near 450 C. It is also found that the PIII nitriding effectiveness appears to be limited by the appearance of uniform corrosion. Finally, X-ray diffraction of the samples has revealed the presence of two new phases, namely {epsilon}-Fe{sub 2}N and Fe{sub 4.4}N, while scanning electron microscopy of the treated surfaces has suggested a sputtering enhancement at the highest temperatures. (Author)

  18. CEMS-investigations of AISI M2 steel after nitrogen plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Uglov, V.V. E-mail: info@research.bsu.unibel.by; Kholmetskii, A.L.; Kuleshov, A.K.; Fedotova, J.A.; Rusalsky, D.P.; Khodasevich, V.V.; Ruebenbauer, K.; Richter, E.; Guenzel, R.; Parascandola, S

    1999-01-02

    Plasma-immersion ion implantation (PIII) and high-current ion implantation (HCII) of nitrogen into M2 steel were carried out. The formation of a multilayer system consisting of a surface layer of austenite on top of {epsilon}-Fe{sub 3}N nitride precipitates was manifested in M2 steel after PIII. HCII forms a thick (more than 14 {mu}m) layer with {epsilon}-Fe{sub 3}N precipitates. Apparently, the formation of the austenite layer after PIII is connected with a local tempering of the steel surface by the pulsed nitrogen ion beam.

  19. Effects of carbon and nitrogen on the elastic constants of AISI (American Iron and Steel Institute) type 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Ledbetter, H.M.; Austin, M.W.

    1985-01-01

    Nine AISI type 304 stainless steel alloys were studied at room temperature. The carbon-plus-nitrogen contents of these alloys ranged from 0.067 to 0.325 wt.% (from 0.3 to 1.3 at. %). Five elastic constants (the longitudinal modulus, Young's modulus, the shear modulus, the bulk modulus and Poisson's ratio) were determined by a pulse echo ultrasonic method.

  20. Hydrogen Cracking in Gas Tungsten Arc Welding of an AISI Type 321 Stainless Steel

    Science.gov (United States)

    Rozenak, P.; Unigovski, Ya.; Shneck, R.

    The effects of in situ cathodic charging on the tensile properties and susceptibility to cracking of an AISI type 321 stainless steel, welded by the gas tungsten arc welding (GTAW) process, was studied by various treatments. Appearance of delta-ferrite phase in the as-welded steels in our tested conditions was observed with discontinuous grain boundaries (M23C6) and a dense distribution of metal carbides MC ((Ti, Nb)C), which precipitated in the matrix. Shielding gas rates changes the mechanical properties of the welds. Ultimate tensile strength and ductility are increases with the resistance to the environments related the increase of the supplied shielding inert gas rates. Charged specimens, caused mainly in decreases in the ductility of welded specimens. However, more severe decrease in ductility was obtained after post weld heat treatment (PWHT). The fracture of sensitized specimens was predominantly intergranular, whereas the as-welded specimens exhibited massive transgranular regions. Both types of specimen demonstrated narrow brittle zones at the sides of the fracture surface and ductile micro-void coalescences in the middle. Ferrite δ was form after welding with high density of dislocation structures and stacking faults formation and the thin stacking fault plates with e-martensite phase were typically found in the austenitic matrix after the cathodical charging process.

  1. Study of the tensile behavior of AISI type 316 stainless steel using acoustic emission and infrared thermography techniques

    Directory of Open Access Journals (Sweden)

    Thodamrakandy Haneef

    2015-07-01

    Full Text Available Acoustic emission (AE and infrared thermography technique (IRT have been used to study the tensile behavior of AISI type 316 stainless steel. Strain rates of tensile testing were varied from 1.4 × 10−3 s−1 to 1.4 × 10−2 s−1. AE root mean square voltage increases with increase in strain rate due to the increase in source activation. Dominant frequency of the AE signals generated during different regions of tensile deformation has also been used to compare the results for different strain rates. The dominant frequency increases from elastic region to around 590 kHz during work hardening and 710 kHz around ultimate tensile strength (UTS for all the strain rates. Temperature changes during different regions of deformation are monitored using infrared thermography. The temperature rise in the work hardening region is found to approximately increase linearly with time and from the slopes of the linear regression analyses the rate of temperature rise in the work-hardening region is obtained which is found to be very sensitive to strain rates. From the experimental results an empirical equation that relates the rate of temperature increase with strain rate and thermal hardening coefficient is obtained. The correlation between the variation of AE dominant frequency and temperature rise during different deformation regions provided better insight into the tensile behavior of AISI type 316 SS for different strain rates.

  2. Enhanced mechanical properties of type AISI301LN austenitic stainless steel through advanced thermo mechanical process

    Energy Technology Data Exchange (ETDEWEB)

    Huang Junxia, E-mail: huangjunxia@baosteel.com [Shanghai Baosteel Research Institute, Shanghai 200431 (China); Ye Xiaoning; Gu Jiaqing; Chen Xu [Shanghai Baosteel Research Institute, Shanghai 200431 (China); Xu Zhou [School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer 69% of strain induced martensite were obtained after 80% thickness reduction at 0 Degree-Sign C. Black-Right-Pointing-Pointer The best annealing regime was determined for diffusional controlled reversion. Black-Right-Pointing-Pointer The effect of grain size on mechanical properties conforms with the H-P relationship. - Abstract: The effect of annealing temperature and time on the grain size of reversed austenite and mechanical properties was studied based on AISI301LN austenitic stainless steel in this paper. Cold rolling at 0 Degree-Sign C was employed to obtain the strain-induced martensite, followed by annealing treatment at the temperature range of 650-900 Degree-Sign C for 1-20 min. The relationship between the volume fraction of strain-induced martensite and cold reduction was analyzed by Ferritescope MP30 and X-ray diffraction. The grain growth of reversed austenite was observed by FEG-SEM and the mechanical properties were determined by tensile tests and Vickers hardness tests. Austenite grain sizes under 3 {mu}m can be obtained after annealing in the range of 700-900 Degree-Sign C for 1-20 min. The finest austenite grain size was produced after annealing at 700 Degree-Sign C for 20 min, which had a good combination of yield strength ( Almost-Equal-To 830 MPa), tensile strength ( Almost-Equal-To 953 MPa) and elongation ( Almost-Equal-To 36%).

  3. Cochlear implant in incomplete partition type I.

    Science.gov (United States)

    Berrettini, S; Forli, F; De Vito, A; Bruschini, L; Quaranta, N

    2013-02-01

    In this investigation, we report on 4 patients affected by incomplete partition type I submitted to cochlear implant at our institutions. Preoperative, surgical, mapping and follow-up issues as well as results in cases with this complex malformation are described. The cases reported in the present study confirm that cochlear implantation in patients with incomplete partition type I may be challenging for cochlear implant teams. The results are variable, but in many cases satisfactory, and are mainly related to the surgical placement of the electrode and residual neural nerve fibres. Moreover, in some cases the association of cochlear nerve abnormalities and other disabilities may significantly affect results.

  4. Processing of AISI M2 HSS with addition of NbC by mechanical alloying using two different types of attritor mills

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Filho, Oscar Olimpio de; Gonzalez, Cezar Henrique; Urtiga Filho, Severino Leopoldino, E-mail: oscaroaf98@hotmail.com, E-mail: gonzalez@ufpe.br, E-mail: urtiga@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Engenharia Mecanica; Neves, Mauricio David Martins das, E-mail: mdneves@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ambrozio Filho, Francisco, E-mail: ambrozio@fei.edu.br [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil)

    2009-07-01

    The processing of a molybdenum AISI M2 high speed steel with the addition of NbC (6% in mass) by a Powder Metallurgy technique of Mechanical Alloying is the aim of this work. Mechanical Alloying (MA) has been used primarily for particle size reduction, to its present status as an important method for the preparation of either materials with enhanced physical and mechanical properties or, indeed, new phases, or new engineering materials. In this work, niobium carbide (NbC) was added to the AISI M2 HSS powders by Mechanical Alloying technique in two different types of attritor mills and the materials which resulted were characterized by means of SEM plus EDS. The powders were processed in a horizontal attritor Zoz mill and in a vertical attritor mill developed in our laboratory. The parameters of milling were distinct and the results of the processing were compared. (author)

  5. Standard test method for electrochemical reactivation (EPR) for detecting sensitization of AISI type 304 and 304L stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers a laboratory procedure for conducting an electrochemical reactivation (EPR) test on AISI Type 304 and 304L (UNS No. S30400 and S30403, respectively) stainless steels. This test method can provide a nondestructive means of quantifying the degree of sensitization in these steels (1, 2, 3). This test method has found wide acceptance in studies of the effects of sensitization on intergranular corrosion and intergranular stress corrosion cracking behavior (see Terminology G15). The EPR technique has been successfully used to evaluate other stainless steels and nickel base alloys (4), but the test conditions and evaluation criteria used were modified in each case from those cited in this test method. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this...

  6. Prediction for pitting corrosion of AISI type 403 stainless steel in chloride-containing borate buffer solution

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yancheng [Pennsylvania State Univ. (United States); Macdonald, D.D. [Pennsylvania State Univ. (United States). Center for Electrochemical Science and Technology; Urquidi-Macdonald, M. [Pennsylvania State Univ. (United States). Engineering Science and Mechanics; Engelhardt, G.R. [OLI Systems, Inc. (United States); Dooley, R.B. [Electric Power Research Inst., Palo Alto, CA (United States). Materials and Chemistry Performance Dept.

    2007-07-15

    The prediction of pitting corrosion damage on low-pressure steam turbine (LPST) blade surfaces has been investigated experimentally and the results have been interpreted in terms of the Point Defect Model (PDM) for passivity breakdown and the nucleation of pits. Experimental relationships between the critical breakdown potential (Vc) and the chloride activity aCl- and pH have demonstrated the applicability of the PDM for describing passivity breakdown on AISI Type 403 stainless steel (SS), a commonly employed blade alloy in LPSTs, in chloride-containing borate buffer solutions. The model parameter values, as determined by optimization of the PDM on passivity breakdown data, may be used to predict the nucleation and accumulation of pitting damage on LPST blades under simulated turbine shutdown conditions. In order to evaluate the predictions, integral damage functions (IDFs) and extreme value distributions in pit depth have been measured on samples taken from failed blades recovered from the field (Texas Genco). These data are being used to test the predictions of Damage Function Analysis (DFA), which is based on the PDM and on deterministic models for pit growth and delayed repassivation. However, the success of this analysis critically depends on our ability to define the corrosion evolutionary path. (orig.)

  7. Comparing the Formability of AISI 304 and AISI 202 Stainless Steels

    Science.gov (United States)

    du Toit, M.; Steyn, H. G.

    2012-07-01

    The formability of AISI 202 austenitic stainless steel was compared with that of type AISI 304 stainless steel. Type 202 is a low-nickel austenitic stainless steel alloyed with manganese and nitrogen. In this study, the formability of the two grades was examined using Erichsen cupping tests and room temperature uniaxial tensile tests performed at various angles to the rolling direction. AISI 202 appears to work-harden at a slightly higher rate than AISI 304, even though the austenite in type 202 is more stable than that in 304 with respect to the formation of deformation-induced α' martensite. Although both grades are predicted to be susceptible to earing during deep drawing, AISI 202 displays a higher work-hardening exponent, higher average normal anisotropy, and a higher limiting drawing ratio than AISI 304. Similar cup heights were measured during Erichsen cupping tests, confirming that the two grades have very similar deep drawing properties. The results of this investigation therefore suggest that AISI 202 is a suitable alternative for AISI 304 in applications requiring good deep drawing properties.

  8. Laser surface cladding of Ti-6Al-4V on AISI 316L stainless steel for bio-implant application

    CSIR Research Space (South Africa)

    Kumar, A

    2014-01-01

    Full Text Available stream_source_info Burger_2014.pdf.txt stream_content_type text/plain stream_size 1476 Content-Encoding UTF-8 stream_name Burger_2014.pdf.txt Content-Type text/plain; charset=UTF-8 Lasers in Eng., Vol. 28, pp. 11–33...

  9. Interstitial-type defects in implanted silicon

    Energy Technology Data Exchange (ETDEWEB)

    Berezhnov, N.I.; Stel' makh, V.F.; Chelyadinskij, A.R.

    1984-07-01

    Boron-, lithium-, phosphorus- and silicon-implanted silicon layers were investigated using X-ray diffraction method for measuring the crystal lattice parameters. It was established that stable interstitial complexes in concentrations comparable with concentrations of vacancy type defects occur in silicon as a result of ion implantation. The interstitial complexes are annealed at the following stages: 1 - 140, 2 - 500 deg C in the case of silicon irradiation by light ions and 1 - 180, 2 - 560 deg C in crystals irradiated by medium mass ions.

  10. Successful rehabilitation of partial edentulous maxilla and mandible with new type of implants: molecular precision implants.

    Science.gov (United States)

    Danza, Matteo; Lauritano, Dorina; Carinci, Francesco

    2014-01-01

    The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  11. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  12. On the corrosion resistance of AISI 316L-type stainless steel coated with manganese and annealed with flow of oxygen

    Science.gov (United States)

    Savaloni, Hadi; Agha-Taheri, Ensieh; Abdi, Fateme

    2016-06-01

    AISI 316L-type stainless steel was coated with 300-nm-thick Mn thin films and post-annealed at 673 K with a constant flow of oxygen (250 cm3/min). The films crystallographic and morphological structures were analyzed using X-ray diffraction (XRD) and atomic force microscopy (AFM) before corrosion test and scanning electron microscopy (SEM) after corrosion test. Corrosion behavior of the samples in 0.3, 0.5 and 0.6 M NaCl solutions was investigated by means of potentiodynamic and electrochemical impedance spectroscopy (EIS) techniques. Results showed that the corrosion inhibition of annealed Mn/SS316L in all NaCl solutions with different concentrations is higher than that of bare SS316L. A correlation is achieved between the structural variation of the films with the potentiodynamic and EIS corrosion results.

  13. Study on the types of craters produced in the impact of projectiles 5,56 SS109, over steel targets AISI-SAE 1045; Estudio de los tipos de crateres obtenidos en el impacto de proyectiles 5,56 SS109, sobre blancos de acero AISI-SAE 1045

    Energy Technology Data Exchange (ETDEWEB)

    Castro, A.; Espejo, E.; Martinez, L. [Universidad Nacional de Colombia. Santa Fe de Bogota (Colombia)

    2000-07-01

    The present work describes the morphology and formation of the types of craters obtained with the impact of projectiles 5,56 SS109 over seven steel plates AISI-SAE 1045 that received different cycles of heat treatment. A comparison between the type of deformation and fracture structures and the ones generated by the impact of this projectiles over one steel armor plate was made. Each one of the craters was characterized by visual and metallography observation. The influence of the plate microstructure on the efficiency for stopping the projectile and the mechanism of craters formation was evaluated. (Author) 10 refs.

  14. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....

  15. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....... and 2 molars were removed in such a manner that in approximately half the cases, the root tips were retained. Following healing, the experimental areas were examined on radiographs, and sites were selected for the insertion of the implants, so that every second implant would have a close contact...

  16. Glycemic control and implant stabilization in type 2 diabetes mellitus.

    Science.gov (United States)

    Oates, T W; Dowell, S; Robinson, M; McMahan, C A

    2009-04-01

    Diabetes mellitus is considered a relative contra-indication for implant therapy. However, the effect of glycemic level on implant integration in persons with diabetes remains poorly understood. The hypothesis of this research was that poor glycemic control is directly related to short-term-impairment implant stabilization. This prospective clinical study evaluated 10 non-diabetic individuals (12 implants) and 20 persons with type 2 diabetes (30 implants). Glycated hemoglobin (HbA1c) levels ranged from 4.7-12.6%. Implant stability was assessed by resonance frequency analysis over 4 months following placement. Minimum stability levels were observed 2-6 weeks following placement for all 42 implants. Persons with HbA1c > or = 8.1% had a greater maximum decrease in stability from baseline and required a longer time for healing, as indicated by return of stability level to baseline. This study demonstrates alterations in implant stability consistent with impaired implant integration for persons with type 2 diabetes mellitus in direct relation to hyperglycemic conditions.

  17. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M;

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  18. Neurofibromatosis type 2 and auditory brainstem implantation

    Institute of Scientific and Technical Information of China (English)

    XIAO Hong-jun; Dennis K.K. Au; Yau Hui; Chun-kuen Chow; Yiu-wah Fan; William Ignace Wei

    2007-01-01

    @@ Neurofibromatosis type 2 (NF-2) is one of the most common single gene disorders in the nervous system.For approximately 96% of patients with NF-2 present with bilateral Schwannomas involving the eighth cranial nerves, which may be accompanied by Schwannomas involving other cranial, spinal or peripheral nerves, NF-2 is also referred to as "bilateral acoustic neuromas".

  19. Penile Implants

    Science.gov (United States)

    ... the discussion with your doctor. Types of penile implants There are two main types of penile implants: ... might help reduce the risk of infection. Comparing implant types When choosing which type of penile implant ...

  20. Canine chondrocytes seeded in type I and type II collagen implants investigated in vitro.

    Science.gov (United States)

    Nehrer, S; Breinan, H A; Ramappa, A; Shortkroff, S; Young, G; Minas, T; Sledge, C B; Yannas, I V; Spector, M

    1997-01-01

    Synthetic and natural absorbable polymers have been used as vehicles for implantation of cells into cartilage defects to promote regeneration of the articular joint surface. Implants should provide a pore structure that allows cell adhesion and growth, and not provoke inflammation or toxicity when implanted in vivo. The scaffold should be absorbable and the degradation should match the rate of tissue regeneration. To facilitate cartilage repair the chemical structure and pore architecture of the matrix should allow the seeded cells to maintain the chondrocytic phenotype, characterized by synthesis of cartilage-specific proteins. We investigated the behavior of canine chondrocytes in two spongelike matrices in vitro: a collagen-glycosaminoglycan (GAG) copolymer produced from bovine hide consisting of type I collagen and a porous scaffold made of type II collagen by extraction of porcine cartilage. Canine chondrocytes were seeded on both types of matrices and cultured for 3 h, 7 days, and 14 days. The histology of chondrocyte-seeded implants showed a significantly higher percentage of cells with spherical morphology, consistent with chondrocytic morphology, in the type II sponge at each time point. Pericellular matrix stained for proteoglycans and for type II collagen after 14 days. Biochemical analysis of the cell seeded sponges for GAG and DNA content showed increases with time. At day 14 there was a significantly higher amount of DNA and GAG in the type II matrix. This is the first study that directly compares the behavior of chondrocytes in type I and type II collagen matrices. The type II matrix may be of value as a vehicle for chondrocyte implantation on the basis of the higher percentage of chondrocytes retaining spherical morphology and greater biosynthetic activity that was reflected in the greater increase of GAG content.

  1. Formation of abrasion-resistant coatings of the AlSiFe{sub x}Mny intermetallic compound type on the AISI 304L alloy

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Peralez, L. G.; Flores-Valdes, A.; Salinas-Rodriguez, A.; Ochoa-Palacios, R. M.; Toscano-giles, J. A.; Torres-Torres, J.

    2016-05-01

    The α-Al{sub 9}FeMnSi and α-Al{sub 9}FeMn{sub 2}Si intermetallics formed by reactive sintering of Al, Si, Mn, Fe, Cr and Ni powders have been used in AISI 304L steels to enhance microhardness. Processing variables of the reactive sintering treatment were temperature (600, 650, 700, 750 and 800 degree centigrade), pressure (5, 10 y 20 MPa) and holding time (3600, 5400 y 7200 seconds). Experimental results show that temperature is the most important variable affecting the substrate/coating formation, while pressure does not appear to have a significant effect. The results show the optimum conditions of the reactive sintering that favor the substrate/coating formation are 800 degree centigrade, 20 MPa and 7200 seconds. Under these conditions, the reaction zone between the substrate and coating is more compacted and well-adhered, with a microhardness of 1300 Vickers. The results of SEM and X-Ray diffraction confirmed the formation of β-Al{sub 9}FeMnSi and β-Al{sub 9}FeMn{sub 2}Si intermetallics in the substrate/coating interface as well as the presence of Cr and Ni, indicating diffusion of these two elements from the substrate to the interface. (Author)

  2. Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.

    Science.gov (United States)

    Calvo, M P; Muller, E; Garg, A K

    2000-01-01

    Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.

  3. Surface fatigue and failure characteristics of hot-forged powder metal AISI 4620, AISI 4640, and machined AISI 4340 steel spur gears

    Science.gov (United States)

    Townsend, Dennis P.

    1987-01-01

    Spur gear surface fatigue endurance tests were conducted to investigate hot forged powder metal AISI 4620 and 4640 steel for use as a gear material, to determine endurance characteristics and to compare the results with machined AISI 4340 and 9310 steel gear materials. The as-forged and unground AISI 4620 gear exhibited a 10 percent fatigue life that was approximately one-fourth of that for AISI 9310 and less than one-half that for the AISI 4340 gears. The forged and finish ground AISI 4620 gears exhibited a 10 percent life, approximately 70 percent that of AISI 9310 and slightly better than that of AISI 4340. The AISI 4640 hot forged gears had less fracture toughness and slightly less fatigue life than the AISI 4620 test gears.

  4. Formation of abrasion-resistant coatings of the AlSiFexMny intermetallic compound type on the AISI 304L alloy

    Directory of Open Access Journals (Sweden)

    Martínez-Perales, Laura G.

    2016-03-01

    Full Text Available The α-Al9FeMnSi and β-Al9FeMn2Si intermetallics formed by reactive sintering of Al, Si, Mn, Fe, Cr and Ni powders have been used in AISI 304L steels to enhance microhardness. Processing variables of the reactive sintering treatment were temperature (600, 650, 700, 750 and 800 °C, pressure (5, 10 y 20 MPa and holding time (3600, 5400 y 7200 seconds. Experimental results show that temperature is the most important variable affecting the substrate/coating formation, while pressure does not appear to have a significant effect. The results show the optimum conditions of the reactive sintering that favor the substrate/coating formation are 800 °C, 20 MPa and 7200 seconds. Under these conditions, the reaction zone between the substrate and coating is more compacted and well-adhered, with a microhardness of 1300 Vickers. The results of SEM and X-Ray diffraction confirmed the formation of α-Al9FeMnSi and β-Al9FeMn2Si intermetallics in the substrate/coating interface as well as the presence of Cr and Ni, indicating diffusion of these two elements from the substrate to the interface.Los intermetálicos α-Al9FeMnSi y β-Al9FeMn2Si formados por sinterización reactiva de polvos Al, Si, Mn, Fe, Cr, Ni se han utilizado en aceros AISI 304L para mejorar la microdureza. Las variables de procesamiento de sinterización reactiva fueron temperatura (600, 650, 700, 750, y 800 °C, presión (5, 10 y 20 MPa y el tiempo de retención (3600, 5400 7200 segundos. Los resultados experimentales muestran que la temperatura es la variable más importante que afecta a la formación del sustrato/recubrimiento, mientras que la presión no parece tener un efecto significativo una influencia significativa. Los resultados muestran las condiciones óptimas de la sinterización reactiva que favorecen la formación del sustrato/recubrimiento a 800 °C, 20 MPa y 7200 segundos. En estas condiciones, la zona de reacción entre el sustrato y el recubrimiento es más compacta y bien

  5. Risk Factors Associated With Complication Rates of Becker-Type Expander Implants in Relation to Implant Survival: Review of 314 Implants in 237 Patients.

    Science.gov (United States)

    Taboada-Suarez, Antonio; Brea-García, Beatriz; Magán-Muñoz, Fernando; Couto-González, Iván; González-Álvarez, Eduardo

    2015-12-01

    Although autologous tissue reconstruction is the best option for breast reconstruction, using implants is still a reliable and simple method, offering acceptable aesthetic results. Becker-type implants are permanent implants that offer a 1-stage reconstructive option. A retrospective study was carried out in our center reviewing the clinical reports of 237 patients, in whom a total of 314 Becker-type prostheses were implanted. Overall survival was calculated using a Kaplan-Meier estimate. Cox proportional hazard models were used to calculate adjusted hazard ratios. At the end of the study, 214 expanders (68.15%) presented no complications, 40 (12.47%) developed significant capsular contracture, in 27 (8.60%) infection occurred, 24 (7.64%) suffered minor complications, and 9 (2.87%) ruptured. The mean survival time of the expanders was 120.41 months (95% CI: 109.62, 131.19). Radiotherapy, chemotherapy, high Molecular Immunology Borstel, age, mastectomy performed previously to the implant, ductal carcinoma, advanced tumoral stage, experience of the surgeon, and Becker 35-type implants were significantly related to a high number of complications in relation to the survival of the implants. Cox regression analysis revealed that the main risk factors for the survival of expander implants included radiotherapy and surgeon experience. The complication hazard ratio or relative risk caused by these 2 factors was 1.976 and 1.680, respectively. One-stage reconstruction using Becker-type expanders is an appropriate, simple, and reliable option in delayed breast reconstruction in patients who have not received radiotherapy and as long as the procedure is carried out by surgeons skilled in the technique.

  6. Surface fatigue and failure characteristics of hot forged powder metal AISI 4620, AISI 4640, and machined AISI 4340 steel spur gears

    Science.gov (United States)

    Townsend, D. P.

    1986-01-01

    Spur gear surface fatigue endurance tests were conducted to investigate hot forged powder metal AISI 4620 and 4640 steel for use as a gear material, to determine endurance characteristics and to compare the results with machined AISI 4340 and 9310 steel gear materials. The as-forged and unground SISI 4620 gear exhibited a 10 percent fatigue life that was approximately one-fourth of that for AISI 9310 and less than one-half that for the AISI 4340 gears. The forged and finish ground AISI 4620 gears exhibited a 10 percent life, approximately 70 percent that of AISI 9310 and slightly better than that of AISI 4340. The AISI 4640 hot forged gears had less fracture toughness and slightly less fatigue life than the AISI 4620 test gears.

  7. Type 2 diabetes mellitus impairs bone healing of dental implants in GK rats.

    Science.gov (United States)

    Wang, Feng; Song, Ying-liang; Li, De-hua; Li, Cui-xia; Wang, Yao; Zhang, Ning; Wang, Bao-gang

    2010-04-01

    Type 2 diabetes is an increasingly prevalent disease with oral health manifestations. In this study, titanium implants were placed in the femora of 10 type 2 diabetic and 10 age-matched normal rats. We compared the results of bone histomorphometry around the dental implants at 4 and 8 weeks postsurgery.

  8. P-Type Doping of GaN by Mg+ Implantation

    Institute of Scientific and Technical Information of China (English)

    YAO Shu-De; ZHAO Qiang; ZHOU Sheng-Qiang; YANG Zi-Jian; LU Yi-Hong; SUN Chang-Chun; SUN Chang; ZHANG Guo-Yi; VANTOMME Andre; PIPELEERS Bert

    2003-01-01

    Mg+ and Mg++P+ were introduced into GaN by ion implantation. The structure and crystalline quality of the GaN samples were analysed by Rutherford backscattering and channelling spectrometry before (xmin = 1.6%) and after implantation (Xmin = 4.1%). X-ray diffraction reveals the existence of implantation-induced damage in the case of post-implantation followed by rapid thermal annealing. The resistivity, average factor, carrier concentration and carrier mobility were measured by the Hall effect. The transformation from n-type to p-type for GaN was observed.

  9. Biological and biomechanical evaluation of interface reaction at conical screw-type implants

    Directory of Open Access Journals (Sweden)

    Seper László

    2006-02-01

    Full Text Available Abstract Background Initial stability of the implant is, in effect, one of the fundamental criteria for obtaining long-term osseointegration. Achieving implant stability depends on the implant-bone relation, the surgical technique and on the microscopic and macroscopic morphology of the implant used. A newly designed parabolic screw-type dental implant system was tested in vivo for early stages of interface reaction at the implant surface. Methods A total of 40 implants were placed into the cranial and caudal part of the tibia in eight male Göttinger minipigs. Resonance frequency measurements (RFM were made on each implant at the time of fixture placement, 7 days and 28 days thereafter in all animals. Block biopsies were harvested 7 and 28 days (four animals each following surgery. Biomechanical testing, removable torque tests (RTV, resonance frequency analysis; histological and histomorphometric analysis as well as ultrastructural investigations (scanning electron microscopy (SEM were performed. Results Implant stability in respect to the measured RTV and RFM-levels were found to be high after 7 days of implants osseointegration and remained at this level during the experimented course. Additionally, RFM level demonstrated no alteration towards baseline levels during the osseointegration. No significant increase or decrease in the mean RFM (6029 Hz; 6256 Hz and 5885 Hz after 0-, 7- and 28 days were observed. The removal torque values show after 7 and 28 days no significant difference. SEM analysis demonstrated a direct bone to implant contact over the whole implant surface. The bone-to-implant contact ratio increased from 35.8 ± 7.2% to 46.3 ± 17.7% over time (p = 0,146. Conclusion The results of this study indicate primary stability of implants which osseointegrated with an intimate bone contact over the whole length of the implant.

  10. Longevity of dental implants in type IV bone: a systematic review.

    Science.gov (United States)

    Goiato, M C; dos Santos, D M; Santiago, J F; Moreno, A; Pellizzer, E P

    2014-09-01

    Bone quality and quantity are important factors with regard to the survival rate of dental implants. The aim of this study was to conduct a systematic review of dental implants inserted in low-density bone and to determine the survival rate of dental implants with surface treatments over time. A systematic review of the literature was undertaken by two independent individuals; the Medline/PubMed database was searched for the period July 1975 to March 2013. Relevant reports on bone quality and osseointegration of dental implants were selected. The search retrieved 1018 references, and after inclusion and exclusion criteria were applied, 19 studies were selected for review. A total of 3937 patients, who had received a total of 12,465 dental implants, were analyzed. The survival rates of dental implants according to the bone density were: type I, 97.6%; type II, 96.2%; type III, 96.5%; and type IV, 88.8%. The survival rate of treated surface implants inserted in low-density bone was higher (97.1%) than that of machined surface implants (91.6%). Surface-treated dental implants inserted in low-density bone have a high survival rate and may be indicated for oral rehabilitation. However, more randomized studies are required to better evaluate this issue.

  11. Formation of p-type ZnO thin film through co-implantation

    Science.gov (United States)

    Chuang, Yao-Teng; Liou, Jhe-Wei; Woon, Wei-Yen

    2017-01-01

    We present a study on the formation of p-type ZnO thin film through ion implantation. Group V dopants (N, P) with different ionic radii are implanted into chemical vapor deposition grown ZnO thin film on GaN/sapphire substrates prior to thermal activation. It is found that mono-doped ZnO by N+ implantation results in n-type conductivity under thermal activation. Dual-doped ZnO film with a N:P ion implantation dose ratio of 4:1 is found to be p-type under certain thermal activation conditions. Higher p-type activation levels (1019 cm-3) under a wider thermal activation range are found for the N/P dual-doped ZnO film co-implanted by additional oxygen ions. From high resolution x-ray diffraction and x-ray photoelectron spectroscopy it is concluded that the observed p-type conductivities are a result of the promoted formation of PZn-4NO complex defects via the concurrent substitution of nitrogen at oxygen sites and phosphorus at zinc sites. The enhanced solubility and stability of acceptor defects in oxygen co-implanted dual-doped ZnO film are related to the reduction of oxygen vacancy defects at the surface. Our study demonstrates the prospect of the formation of stable p-type ZnO film through co-implantation.

  12. Study of residual stresses generated in machining of AISI 4340 steel; Estudo das tensoes residuais geradas na usinagem de aco AISI 4340

    Energy Technology Data Exchange (ETDEWEB)

    Reis, W.P. dos; Fonseca, M.P. Cindra; Serrao, L.F.; Chuvas, T.C.; Oliveira, L.C., E-mail: mcindra@vm.uff.b [Universidade Federal Fluminense (PGMEC/UFF), Niteroi, RJ (Brazil). Dept. de Engenharia Mecanica

    2010-07-01

    Among the mechanical construction steels, AISI 4340 has good harden ability, while combining high strength with toughness and good fatigue strength, making it excellent for application in the metalworking industry, where it can work at different levels and types of requests. Residual stresses are generated in almost all processes of mechanical manufacturing. In this study, the residual stresses generated in different machining processes and heat treatment hardening of AISI 4340 were analyzed by X-ray diffraction, by the sen{sup 2} {psi} method, using Cr{kappa}{beta} radiation and compared. All samples, except for turned and cut by EDM, presented compressive residual stresses in the surface with various magnitudes. (author)

  13. Comparative study of high temperature oxidation behaviour in AISI 304 and AISI 439 stainless steels

    Directory of Open Access Journals (Sweden)

    Antônio Claret Soares Sabioni

    2003-06-01

    Full Text Available This work deals with a comparison of high temperature oxidation behaviour in AISI 304 austenitic and AISI 439 ferritic stainless steels. The oxidation experiments were performed between 850 and 950 °C, in oxygen and Ar (100 vpm H2. In most cases, it was formed a Cr2O3 protective scale, whose growth kinetics follows a parabolic law. The exception was for the the AISI 304 steel, at 950 °C, in oxygen atmosphere, which forms an iron oxide external layer. The oxidation resistance of the AISI 439 does not depend on the atmosphere. The AISI 304 has the same oxidation resistance in both atmospheres, at 850 °C, but at higher temperatures, its oxidation rate strongly increases in oxygen atmosphere. Concerning the performance of these steels under oxidation, our results show that the AISI 439 steel has higher oxidation resistance in oxidizing atmosphere, above 850 °C, while, in low pO2 atmosphere, the AISI 304 steel has higher oxidation resistance than the AISI 439, in all the temperature range investigated.

  14. Intervention for replacing missing teeth: Different types of implants - evidence summary of updated Cochrane review

    Directory of Open Access Journals (Sweden)

    Balendra Pratap Singh

    2015-01-01

    Full Text Available Around 1300 different types of dental implants are available worldwide and the implant manufacturers are resorting to aggressive marketing strategies; claiming their implants to provide a superior outcome. The clinician is left with a constant dilemma on which implant to choose for better clinical outcome and welfare of the patient. Moreover, in India, economical consideration is a concern too. The dentist has to select an implant that provides a good result and is economical. Cochrane systematic reviews provide the gold standard evidence for intervention, diagnosis, etc., and follow a strict quality control. A Cochrane systematic review was done to shed light on whether the different implant surface modifications, shapes or materials significantly influence clinical outcomes. All randomized controlled trials (RCTs till January 17, 2014 were searched and out of the 81 trials, only 27 met the inclusion criteria. This evidence summary from the review concludes that based on the available literature; there is no evidence of any one type of implant being superior to another. There is weak evidence showing roughened dental implants are more prone to bone loss due to periimplantitis. This review indicated that there is a need for well-designed RCTs, with long-term follow-up and low bias. Moreover, none of the included studies was from India, which also points out the need for improving the quality of RCTs conducted in India.

  15. Comparing Round and Anatomically Shaped Implants in Augmentation Mammaplasty: The Experts' Ability to Differentiate the Type of Implant.

    Science.gov (United States)

    Rubi, Carlos G; Lozano, Jose Angel; Pérez-Espadero, Alberto; Leache, M Elena

    2017-01-01

    The purpose of this study was to determine whether the aesthetic results of subpectoral augmentation mammaplasty using anatomically shaped versus round prostheses are differentiable. Thirty observers (i.e., plastic surgeons and nurses) assessed preoperative and postoperative photographs (frontal and oblique views) of 30 patients who had undergone subpectoral augmentation mammaplasty with cohesive silicone gel implants, with an average implant volume of 295 cc (range, 220 to 340 cc). The observers classified each case as round or shaped on two different occasions with a 12-week time interval. A statistical concordance analysis was performed, calculating the overall concordance rate, the interobserver, the intraobserver, and the overall intraobserver kappa indexes, to evaluate the expert observers' capacity to differentiate the implant type. Among the total of 1800 observations (30 observers assessed 30 cases on two occasions), the overall concordance rate was 50.33 percent (95 percent CI, 47.99 to 52.67). The interobserver kappa value was 0.010 (95 percent CI, 0.0025 to 0.04). The overall intraobserver kappa value was 0.0602 (95 percent CI, 0.0025 to 0.123). The observers were unable to recognize the type of implant used, nor was interobserver concordance noted. An agreement was not reached before the different observers, nor was an intraobserver concordance seen between the first and second classifications of the same cases by each observer. The results obtained from subpectoral augmentation mammaplasty using anatomically shaped and round prostheses with a volume of 340 cc or less are indistinguishable, not justifying the systematic use of anatomically shaped implants in this patient. Therapeutic, III.

  16. Influence of direct laser fabrication implant topography on type IV bone: a histomorphometric study in humans.

    Science.gov (United States)

    Shibli, Jamil Awad; Mangano, Carlo; D'avila, Susana; Piattelli, Adriano; Pecora, Gabriele E; Mangano, Francesco; Onuma, Tatiana; Cardoso, Luciana A; Ferrari, Daniel Sanchez; Aguiar, Kelly C; Iezzi, Giovanna

    2010-05-01

    The aim of this histologic study was to evaluate the influence of the direct laser fabrication (DFL) surface topography on bone-to-implant contact (BIC%), on bone density in the threaded area (BA%) as well as bone density outside the threaded area (BD%) in type IV bone after 8 weeks of unloaded healing. Thirty patients (mean age 51.34 +/- 3.06 years) received 1 micro-implant (2.5-mm diameter and 6-mm length) each during conventional implant surgery in the posterior maxilla. Thirty micro-implants with three topographies were evaluated: 10 machined (cpTi); 10 sandblasted and acid etched surface (SAE) and 10 DFL micro-implants. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for histomorphometric analysis. Four micro-implants (2 cpTi, 1 SAE and 1DLF) showed no osseointegration after the healing period. Histometric evaluation indicated that the mean BIC% was higher for the DFL and SAE surfaces (p = 0.0002). The BA% was higher for the DFL surface, although there was no difference with the SAE surface. The BD% was similar for all topographies (p > 0.05). Data suggest that the DFL and SAE surfaces presented a higher bone-to-implant contact rate compared with cpTi surfaces under unloaded conditions, after a healing period of 8 weeks.

  17. Long-term Outcome of Implant Therapy in a Type II Diabetes Mellitus Patient

    OpenAIRE

    FUKUI, TATSUMASA; SHIBATA, Shunichi; Ogawa, Masayuki; OMORI, TOSHIKAZU; Iwasaki, Hitomi; AOSHIBA, HIDEYUKI; MATSUI, KOUSUKE; TSUKAHARA, TAKASHI; FUJIWARA, SHUU; 福井, 達真; 柴田, 俊一; 小川, 雅之; 大森, 俊和; 岩崎, ひとみ; 青芝, 秀幸

    2011-01-01

    In recent years, implant treatment has been used widely for a range of defective morphologies with a high rate of success. The difficulty of initial placement in diabetic patients were well known. This article describes our experience performing implant treatment on a type II diabetes patient 13 year earlier , and our subsequent observation of his progress. Patient: was male, aged 45 years at initial consultation and his underlying disease was diabetes mellitus. The lower left second premolar...

  18. High surface hole concentration p-type GaN using Mg implantation

    CERN Document Server

    Long Tao; Zhang Guo Yi

    2001-01-01

    Mg ions were implanted on Mg-doped GaN grown by metalorganic chemical vapor deposition (MOCVD). The p-type GaN was achieved with high hole concentration (8.28 x 10 sup 1 sup 7 cm sup - sup 3) conformed by Van derpauw Hall measurement after annealing at 800 degree C for 1 h. this is the first experimental report of Mg implantation on Mg-doped GaN and achieving p-type GaN with high surface hole concentration

  19. Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study.

    Science.gov (United States)

    Gümrükçü, Zeynep; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet

    2017-07-01

    The purpose of this study is to evaluate and compare bone stress that occurs as a result of using vertical implants with simultaneous sinus augmentation with bone stress generated from oblique implants without sinus augmentation in atrophic maxilla. Six, three-dimensional (3D) finite element (FE) models of atrophic maxilla were generated with SolidWorks software. The maxilla models were varied for two different bone types. Models 2a, 2b and 2c represent maxilla models with D2 bone type. Models 3a, 3b and 3c represent maxilla models with D3 bone type. Five implants were embedded in each model with different configurations for vertical implant insertion with sinus augmentation: Model 2a/Model 3a, 30° tilted insertion; Model 2b/Model 3b and 45° tilted insertion; Model 2c/Model 3c. A 150 N load was applied obliquely on the hybrid prosthesis. The maximum von Mises stress values were comparatively evaluated using color scales. The von Mises stress values predicted by the FE models were higher for all D3 bone models in both cortical and cancellous bone. For the vertical implant models, lower stress values were found in cortical bone. Tilting of the distal implants by 30° increased the stress in the cortical layer compared to vertical implant models. Tilting of the distal implant by 45° decreased the stress in the cortical bone compared to the 30° models, but higher stress values were detected in the 45° models compared to the vertical implant models. Augmentation should be the first treatment option in atrophic maxilla in terms of biomechanics. Tilted posterior implants can create higher stress values than vertical posterior implants. During tilting implant planning, the use of a 45° tilted implant results in better biomechanical performance in peri-implant bone than 30° tilted implant due to the decrease in cantilever length. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Dental implants as Treatment Option in Patients With Osteopenic Syndrome and Type II Diabetes

    OpenAIRE

    M.V. Kozlova; A.M. Mkrtumjan; A.M. Panin; D.R. Tovmasjan

    2009-01-01

    One of the important problems in modern dentistry is the study of jaw bone changes associated with type II diabetes. The aim of this study is to evaluate the influence of osteopenic syndrome on osseointegration when using dental implants in patients with type II diabetes. 40 patients with type II diabetes have been evaluated and assigned to two different groups based on the duration of the disease. Including criteria in patients with compensated diabetes were fasting glucose test results <...

  1. Repetitive subcutaneous implantation of different types of (biodegradable) biomaterials alters the foreign body reaction

    NARCIS (Netherlands)

    van Luyn, MJA; Plantinga, JA; Brouwer, LA; Khouw, IMSL; de Leij, LFMH; van Wachem, PB

    2001-01-01

    In the present study two biodegradable materials (cross-linked collagens) and two non-biodegradable materials (polyurethane and silicone) were applied in a repetitive subcutaneous implantation model in rats. In contrast to the first challenge, the second challenge with the same type of material, but

  2. Multiple implantation and multiple annealing of phosphorus doped germanium to achieve n-type activation near the theoretical limit

    Science.gov (United States)

    Kim, Jeehwan; Bedell, Stephen W.; Sadana, Devendra K.

    2012-09-01

    Full activation of n-type dopant in germanium (Ge) reaching to its solid solubility has never been achieved by using ion implantation doping technique. This is because implantation of dopants always leaves defects such as vacancy and interstitials in the Ge crystal. While implantation-induced defects are electrically neutral for the most of semiconductor materials, they are electrically positive for Ge resulting in compensation of n-type dopants. In this Letter, we verified that 5 × 1019 P/cm3 is the maximum active concentration, which can be fully activated in germanium "without leaving implantation damage" per implantation/annealing cycle. The repetition of implantation and annealing of phosphorous (P) with the concentration of 5 × 1019 cm-3 leads to the activation of 1 × 1020 P/cm3 close to its solid solubility limit of 2 × 1020 P/cm3.

  3. An investigation on weldability of AISI 304 and AISI 1040 steels on friction welding; Untersuchung der Schweisseignung von AISI 304 und AISI 1040 mittels Reibschweissen

    Energy Technology Data Exchange (ETDEWEB)

    Celik, Sare; Ay, Irfan [Balikesir Univ., Cagis Campus (Turkey). Mechanical Eng. Dept.; Dinc, Dincer [General Directorate of Highways, Canakkale (Turkey); Yaman, Ramazan [Balikesir Univ., Cagis Campus (Turkey). Industrial Eng. Dept.

    2010-04-15

    In welding technology, joining processes of different materials, which have dissimilar crystal structures are difficult. Welding of different materials becomes very important to reduce costs. Furthermore, the friction welding method is processed in lower temperature than the melting temperature. Especially, this is a big advantage to overcome difficulties that occur in the heat affected zone during usage of conventional methods. In this study, the weldability of AISI 304 stainless steel and AISI 1040 carbon steel by friction welding is studied. During the welding process, temperature variations in the welding zones were measured with an infrared temperature measurement device. After welding of the samples, tensile and hardness experiments were carried out. For metallographic investigations, optical microscope and scanning electron microscope (SEM) pictures were taken. Energy dispersive spectroscopy (EDS) analysis was carried out for composition investigations on welding and heat affected zones. As a result, these two steels could be joined by friction welding for industrial usage.

  4. State on AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    A. Fattah-alhosseini

    2011-01-01

    Full Text Available The passivity and protective nature of the passive films are essentially related to ionic and electronic transport processes, which are controlled by the optical and electronic properties of passive films. In this study, the electrochemical behavior of passive films anodically formed on AISI 304 stainless steel in sulfuric acid solution has been examined using electrochemical impedance spectroscopy. AISI 304 in sulphuric acid solution is characterized by high interfacial impedance, thereby illustrating its high corrosion resistance. Results showed that the interfacial impedance and the polarization resistance (pol initially increase with applied potential, within the low potential passive. However, at a sufficiently high potential passive (>0.4 V, the interfacial impedance and the polarization resistance decrease with increasing potential. An electrical equivalent circuit based on the impedance analysis, which describes the behavior of the passive film on stainless steel more satisfactorily than the proposed models, is presented.

  5. Micro-CT evaluation of in vivo osteogenesis at implants processed by wire-type electric discharge machining.

    Science.gov (United States)

    Yamaki, Koichi; Kataoka, Yu; Ohtsuka, Fukunaga; Miyazaki, Takashi

    2012-01-01

    Titanium surfaces processed by wire-type electric discharge machining (EDM) are microfabricated surfaces with an irregular morphology, and they exhibited excellent in vitro bone biocompatibility. In this study, the efficiency of in vivo osteogenesis on EDM surfaces was investigated by surgically placing screw-shaped EDM-processed and machined-surface implants into the femurs of four Japanese white rabbits. The volume and process of new bone formation were evaluated by an X-ray micro-CT scanner, coupled with histopathological observations at 1, 2, and 4 weeks post-implantation. Before surgical implantation, the surface topography and contact angle of each implant surface were examined. Bone formation increased over time on both implant surfaces, with both implant types yielding statistically equivalent bone volume at 4 weeks post-implementation. However, at 1 week post-implantation, amount of new bone at EDM-processed implant was markedly greater than that at machined-surface implant. Moreover, new bone appeared to initiate directly from the EDM surfaces, while new bone appeared to generate from pre-existing host bone to the machined surfaces. Thus, EDM seemed to be a promising method for surface modification of titanium implants to support enhanced osteogenesis.

  6. Characterization of AISI 4140 borided steels

    Energy Technology Data Exchange (ETDEWEB)

    Campos-Silva, I., E-mail: icampos@ipn.mx [Instituto Politecnico Nacional, Grupo Ingenieria de Superficies, SEPI-ESIME U.P. Adolfo Lopez Mateos, Zacatenco, Mexico D.F., 07738 (Mexico); Ortiz-Dominguez, M.; Lopez-Perrusquia, N.; Meneses-Amador, A. [Instituto Politecnico Nacional, Grupo Ingenieria de Superficies, SEPI-ESIME U.P. Adolfo Lopez Mateos, Zacatenco, Mexico D.F., 07738 (Mexico); Escobar-Galindo, R. [Instituto de Ciencia de Materiales de Madrid (CSIC), E-28049 Cantoblanco, Madrid (Spain); Martinez-Trinidad, J. [Instituto Politecnico Nacional, Grupo Ingenieria de Superficies, SEPI-ESIME U.P. Adolfo Lopez Mateos, Zacatenco, Mexico D.F., 07738 (Mexico)

    2010-02-01

    The present study characterizes the surface of AISI 4140 steels exposed to the paste-boriding process. The formation of Fe{sub 2}B hard coatings was obtained in the temperature range 1123-1273 K with different exposure times, using a 4 mm thick layer of boron carbide paste over the material surface. First, the growth kinetics of boride layers at the surface of AISI 4140 steels was evaluated. Second, the presence and distribution of alloying elements on the Fe{sub 2}B phase was measured using the Glow Discharge Optical Emission Spectrometry (GDOES) technique. Further, thermal residual stresses produced on the borided phase were evaluated by X-ray diffraction (XRD) analysis. The fracture toughness of the iron boride layer of the AISI 4140 borided steels was estimated using a Vickers microindentation induced-fracture testing at a constant distance of 25 {mu}m from the surface. The force criterion of fracture toughness was determined from the extent of brittle cracks, both parallel and perpendicular to the surface, originating at the tips of an indenter impression. The fracture toughness values obtained by the Palmqvist crack model are expressed in the form K{sub C}({pi}/2) > K{sub C} > K{sub C}(0) for the different applied loads and experimental parameters of the boriding process.

  7. Estimation of embrittlement during aging of AISI 316 stainless steel TIG welds

    Indian Academy of Sciences (India)

    J Nayak; K R Udupa; K R Hebbar; H V S Nayak

    2004-12-01

    Weldments of AISI grade 316 stainless steel, having a ferrite content of 4–6% and a variety of nitrogen concentrations were prepared using a modified element implant technique. Charpy impact specimens prepared from these weldments were subjected to a variety of aging treatments. Impact toughness decreases with aging time at all aging temperatures. Nitrogen is found to be beneficial to toughness. An empirical relation connecting the aging temperature, aging time and nitrogen content with toughness has been developed which can be used to estimate the time for embrittlement.

  8. p-Type Quasi-Mono Silicon Solar Cell Fabricated by Ion Implantation

    Directory of Open Access Journals (Sweden)

    Chien-Ming Lee

    2013-01-01

    Full Text Available The p-type quasi-mono wafer is a novel type of silicon material that is processed using a seed directional solidification technique. This material is a promising alternative to traditional high-cost Czochralski (CZ and float-zone (FZ material. Here, we evaluate the application of an advanced solar cell process featuring a novel method of ion implantation on p-type quasi-mono silicon wafer. The ion implantation process has simplified the normal industrial process flow by eliminating two process steps: the removal of phosphosilicate glass (PSG and the junction isolation process that is required after the conventional thermal POCl3 diffusion process. Moreover, the good passivation performance of the ion implantation process improves Voc. Our results show that, after metallization and cofiring, an average cell efficiency of 18.55% can be achieved using 156 × 156 mm p-type quasi-mono silicon wafer. Furthermore, the absolute cell efficiency obtained using this method is 0.47% higher than that for the traditional POCl3 diffusion process.

  9. Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types.

    Science.gov (United States)

    Howashi, Miori; Tsukiyama, Yoshihiro; Ayukawa, Yasunori; Isoda-Akizuki, Kei; Kihara, Masafumi; Imai, Yu; Sogo, Motofumi; Koyano, Kiyoshi

    2016-02-01

    Studies have shown that bone quality at the implant recipient site can influence primary stability. The aims of this study were to explore the quantitative estimation of the primary stability of implants preoperatively using CT values and to examine the effect of different implant designs with recommended socket preparation on primary stability. Forty-four fresh porcine femoral heads were prepared. The bone surrounding implant sockets was preoperatively evaluated by helical CT. Forty-four implants (φ 4.3 × 10 mm), 22 straight and 22 tapered, were placed according to the manufacturer's instructions. The insertion torque value (ITV), implant stability quotient (ISQ), and removal torque value (RTV) were recorded as indicators of primary implant stability. Significant correlations and linear relationships were found between the CT value and ITV, ISQ, and RTV for both straight and tapered implants (Spearman's correlation coefficient, p quantitatively estimated using the CT value preoperatively, indicating the CT value of bone surrounding an implant can contribute considerably to implant planning and design choice in clinical situations. © 2014 Wiley Periodicals, Inc.

  10. Tissue response to a new type of biomaterial implanted subcutaneously in rats

    DEFF Research Database (Denmark)

    Boennelycke, Marie; Christensen, Lise; Nielsen, Lene Feldskov

    2011-01-01

    A new type of resorbable biomaterial intended for pelvic reconstruction was tested with respect to tissue regeneration and biocompatibility in rats. The biomaterial consisted of methoxypolyethyleneglycol-poly (lactic-co-glycolic acid) (MPEG-PLGA). Implants were pure, enriched with extra-cellular ......A new type of resorbable biomaterial intended for pelvic reconstruction was tested with respect to tissue regeneration and biocompatibility in rats. The biomaterial consisted of methoxypolyethyleneglycol-poly (lactic-co-glycolic acid) (MPEG-PLGA). Implants were pure, enriched with extra...... of tissue regeneration. Thus, it is hardly a candidate per se in reinforcement of pelvic reconstruction, but it could have a future role as carrier for stem cells....

  11. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  12. Simulated bone remodeling around two types of osseointegrated implants for direct fixation of upper-leg prostheses

    NARCIS (Netherlands)

    Tomaszewski, P.K.; Verdonschot, N.; Bulstra, S.K.; Rietman, J.S.; Verkerke, G.J.

    2012-01-01

    Direct attachment of an upper leg prosthesis to the skeletal system by a percutaneous implant is an alternative solution to the traditional socket fixation. In this study, we investigated long-term periprosthetic bone changes around two types of fixation implants using two different initial conditio

  13. Effects of Three Types of Long-acting Contraceptive Implants on Menstrual Blood Loss in 89 Women

    Institute of Scientific and Technical Information of China (English)

    韩丽晖; 范慧民; 龚泉; 谢争; 孟凡; 洪玉凤; 王文娟

    1999-01-01

    Objective: To study the effects of three types of contraceptive implants: the domestic No I , No I implants and Norplant on menstrual blood loss (MBL). Method: Eighty-nine healthy subjects were randomly allocated to three groups.Menstrual blood loss was measured before implanting and 3, 6, and 12 months after implantation. Results: MBL of the three groups prior to the use of implant were 43. 3±6. 9ml,48.9±4. 3 ml, and 43.7±5. 5ml respectively, and decreased significantly at all post-implantation periods. MBLs were 32. 8±13. 2ml, 24. 8±5. 5ml, and 19. 7±9.3ml at the 3rd month after implantation and 23. 9±5. 9 ml, 40. 8±10. 4 ml, 25. 9±6. 0 ml at the 12th month after implantation respectively, sigmficantly less than before implantation(P<0. 05~0. 01). A tendency was seen in increase of hemoglobin concentraition. Conclusion: Long-acting contraceptive implants decreased menstrual blood loss and elevates hemoglobin concentration. They are applicable to women as a contraceptive method without blood loss effects.

  14. [Implant placement with metal ceramic restorations in a patient with type II diabetes and asthma].

    Science.gov (United States)

    Kuznetsov, S V; Markina, M S

    2013-01-01

    In out-patient dental care a history of somatic pathology is of vital importance. Unfortunately patients are not always compliant enough not understanding the impact of somatic pathology on dental treatment. The current paper presents a case of dental implant placement and splint bridge fixation in a patient with type II diabetes and asthma. The authors summarize the most useful recommendations for treatment and follow-up of such patients.

  15. Robust p-type doping of copper oxide using nitrogen implantation

    Science.gov (United States)

    Jorge, Marina; Polyakov, Stanislav M.; Cooil, Simon; Schenk, Alex K.; Edmonds, Mark; Thomsen, Lars; Mazzola, Federico; Wells, Justin W.

    2017-07-01

    We demonstrate robust p-type doping of Cu2O using low/medium energy ion implantation. Samples are made by controlled oxidation of annealed Cu metal foils, which results in Cu2O with levels of doping close to intrinsic. Samples are then implanted with nitrogen ions using a kinetic energy in the few keV range. Using this method, we are able to produce very high levels of doping, as evidenced by a 350 meV shift in the Fermi level towards the VB maximum. The robustness of the nitrogen implanted samples are tested by exposing them to atmospheric contaminants, and elevated temperatures. The samples are found to survive an increase in temperature of many hundreds of degrees. The robustness of the samples, combined with the fact that the materials used are safe, abundant and non-toxic and that the methods used for the growth of Cu2O and N+ implantation are simple and cheap to implement industrially, underlines the potential of Cu2O:N for affordable intermediate band photovoltaics.

  16. Effect of irrigation and stainless steel drills on dental implant bed heat generation.

    Science.gov (United States)

    Bullon, B; Bueno, E F; Herrero, M; Fernandez-Palacin, A; Rios, J V; Bullon, P; Gil, F J

    2015-02-01

    The objective of this study is assessing the influence of the use of different drill types and external irrigation on heat generation in the bone. In-vitro study to compare two different sequences for implant-bed preparation by means of two stainless steels: precipitation-hardening stainless steel (AISI 420B) (K drills), and martensitic stainless steel (AISI 440) (S drills). Besides, the drilled sequences were realized without irrigation, and with external irrigation by means of normal saline solution at room temperature. The study was realized on bovine ribs using: K without irrigation (KSI) and with irrigation (KCI) and S without irrigation (SSI) and with irrigation (SCI) with five drills for each system. Each drill was used 100 times. Bone temperature was measured with a thermocouple immediately after drilled. Average bone temperature with irrigation was for K drills 17.58±3.32 °C and for S drills 16.66±1.30 °C. Average bone temperature without irrigation was for K drills 23.58±2.94 °C and for S drills 19.41±2.27 °C. Statistically significant differences were found between K without irrigation versus S with irrigation and K with irrigation (pirrigated groups (K=5.6%, S=5.1% vs. without irrigation groups K=9.4%, S=9.3%). The first K drill generated more heat than the remaining drills. No significant differences were detected among temperature values in any of the analyzed drill groups. Unlike irrigation, drill use and type were observed to have no significant impact on heat generation. The stainless steel AISI 420B presents better mechanical properties and corrosion resistance than AISI440.

  17. Comparison of Anchorage Pattern under Two Types of Orthodontic Mini- Implant Loading During Retraction in Type A Anchorage Cases

    Science.gov (United States)

    Khan, B. Imran; Mandava, Prasad; Reddy, G. Vivek; Nettam, Venkatesh; Bhavikati, Venkat Naidu

    2016-01-01

    Introduction The orthodontic mini-screws are the mainstay of direct skeletal anchorage which requires minimal compliance and provides maximal anchorage control. However, the timing of initiation of orthodontic loading of these mini-screws is not clearly established in the available studies. Aim The purpose of this study was to determine the reciprocal effects on mini-screw implant with immediate loading in comparison to that of delayed loading during retraction. Materials and Methods The prospective clinical study included a sample of 25 orthodontic patients in the age range of 18-25 years. All the cases were of bi-maxillary proclination with Type-A anchorage demands. All the first premolars were indicated for extraction. A split mouth technique for each patient was utilized by loading mini-implant immediately after its placement on one side and the opposite side implant was loaded after a time lag of two weeks post-insertion. Retraction force of 150g was applied for three months on each side. The displacement of the head and tail of the implant, molar anterior tooth retraction was measured on Orthopantomograph (OPG) taken at T1 (initial) and T2 (after three months). A grid method with each 1mm magnified to 500 pixels was superimposed on OPG and the relative displacements were evaluated. Student’s unpaired ‘t’ test was used for comparison between left and right side and paired ‘t’ test for the parameters on the same side. The p-value equal to or less than 0.05 was taken as statistically significant. Results The mean displacement of head of the implant on the immediate loading is 0.57mm where as the tail exhibited 0.75 mm. The head and tail of the implant on the delayed loading displaced by 0.35mm and 0.38mm respectively, on an average when data was analysed. Significant difference between the two types of loading was noted. Conclusion Delayed loading is beneficial as compared to immediate loading during extraction space closure. PMID:27891469

  18. Conventional SLA and chemically modified SLA implants in patients with poorly controlled type 2 diabetes mellitus--a randomized controlled trial.

    Science.gov (United States)

    Khandelwal, Namita; Oates, Thomas W; Vargas, Adriana; Alexander, Peggy P; Schoolfield, John D; Alex McMahan, C

    2013-01-01

    The objective of this study was to evaluate the potential for a chemically modified Sand blasted, Large grit, Acid etched (SLA) surface, compared with a conventional SLA surface, to enhance implant healing and integration in poorly controlled diabetic patients, a group previously demonstrated to have compromises and delays in implant stabilization during the metabolically active healing period following implant placement. The study enrolled 24 patients with type 2 diabetes, baseline HbA1c levels between 7.5-11.4%, and a minimum of two posterior mandibular tooth sites at least 4 months following extraction and appropriate for implant placement. Each patient, at a randomly selected site, received an implant with the conventional SLA surface; at the second site, the patient received an implant with the chemically modified SLA (modSLA) surface. Thus, 48 study implants were placed. Implant stability was assessed using Resonance Frequency Analysis (RFA). Readings were taken from the buccal and proximal directions for each implant. Implant stability (ISQ) was assessed at the time of surgical placement (baseline) and 2, 3, 4, 6, 8, 10, 12, and 16 weeks following implant placement. No significant differences in implant stability were observed between conventional SLA implants and modSLA implants, and the time courses of implant stabilization following implant placement were similar for the two implant types. Baseline ISQ and minimum ISQ was slightly higher in subjects with higher HbA1c levels, but were similar during 12-16 weeks following implant placement. Forty-seven (98%) of the 48 implants were determined to be successfully osseointegrated and continued to restoration. Implant stabilization was similar for the conventional SLA and chemically modified SLA implants in type 2 diabetic patients with relatively poor glycemic control. Furthermore, this study demonstrated clinically successful implant placement even in poorly controlled diabetic patients. © 2011 John Wiley

  19. Initiation and growth of thermal fatigue crack networks in an AISI 304 L type austenitic stainless steel (X2 CrNi18-09); Amorcage et propagation de reseaux de fissures de fatigue thermique dans un acier inoxydable austenitique de type X2 CrNi18-09 (AISI 304 L)

    Energy Technology Data Exchange (ETDEWEB)

    Maillot, V

    2004-07-01

    We studied the behaviour of a 304 L type austenitic stainless steel submitted to thermal fatigue. Using the SPLASH equipment of CEA/SRMA we tested parallelepipedal specimens on two sides: the specimens are continuously heated by Joule effect, while two opposites faces are cyclically. cooled by a mixed spray of distilled water and compressed air. This device allows the reproduction and the study of crack networks similar to those observed in nuclear power plants, on the inner side of circuits fatigued by mixed pressurized water flows at different temperatures. The crack initiation and the network constitution at the surface were observed under different thermal conditions (Tmax = 320 deg C, {delta}T between 125 and 200 deg C). The experiment produced a stress gradient in the specimen, and due to this gradient, the in-depth growth of the cracks finally stopped. The obtained crack networks were studied quantitatively by image analysis, and different parameters were studied: at the surface during the cycling, and post mortem by step-by-step layer removal by grinding. The maximal depth obtained experimentally, 2.5 mm, is relatively coherent with the finite element modelling of the SPLASH test, in which compressive stresses appear at a depth of 2 mm. Some of the crack networks obtained by thermal fatigue were also tested in isothermal fatigue crack growth under 4-point bending, at imposed load. The mechanisms of the crack selection, and the appearance of the dominating crack are described. Compared to the propagation of a single crack, the crack networks delay the propagation, depending on the severity of the crack competition for domination. The dominating crack can be at the network periphery, in that case it is not as shielded by its neighbours as a crack located in the center of the network. It can also be a straight crack surrounded by more sinuous neighbours. Indeed, on sinuous cracks, the loading is not the same all along the crack path, leading to some

  20. Influence of implant location in patients with and without type 2 diabetes mellitus: 2-year follow-up.

    Science.gov (United States)

    Abduljabbar, T; Javed, F; Malignaggi, V R; Vohra, F; Kellesarian, S V

    2017-09-01

    The aim of the present cross-sectional retrospective 2-year follow-up clinical study was to assess the influence of implant location on clinical and radiographic parameters around dental implants placed in patients with and without type 2 diabetes mellitus (T2DM). Twenty-seven patients with T2DM and 25 non-diabetic controls were included. Implants were classified into three zones according to their location: (1) anterior zone: implant/s replacing anterior teeth, (2) middle zone: implant/s replacing premolars, and (3) posterior zone: implant/s replacing molars. Peri-implant bleeding on probing (BOP), probing depth (PD), and crestal bone loss (CBL) were measured. P-values less than 0.05 were considered statistically significant. The mean age of patients with T2DM was 42.5 years and that of non-diabetic controls was 40.6 years. The mean fasting blood glucose levels of patients with and without T2DM were 74.5mg/dl (66-80mg/dl) and 82.5mg/dl (79-88.1mg/dl), respectively. The mean duration of T2DM was 4.3 years. There was no significant difference in BOP, PD, or CBL around implants placed in any of the zones in the jaws of patients with and without T2DM. There is no influence of implant location on clinical and radiographic parameters around dental implants placed in patients with and without T2DM. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. COLD ROLLING ORTHODONTIC WIRES OF AUSTENITIC STAINLESS STEEL AISI 304

    Directory of Open Access Journals (Sweden)

    Rodrigo Santos Messner

    2013-03-01

    Full Text Available Austenitic stainless steels wires are widely used in the final stages of orthodontic treatment. The objective of this paper is to study the process of conformation of rectangular wires from round wires commercial austenitic stainless steel AISI 304 by the process of cold rolling. The wire quality is evaluated by means of dimensional analysis, microhardness measurements, tensile strength and fractographic analysis of the wires subjected to tensile tests. Also a study on the application of finite element method to simulate the process, comparing the force and rolling stress obtained in the rolling is done. The simulation results are consistent with those obtained in the actual process and the rolled wires show ductile fracture, tensile strength and dimensional variations appropriate to orthodontic standards. The fracture morphology shows the model cup-cone type besides the high deformation and hardness inherent in the cold rolling process.

  2. [Type-I and -II estradiol binding sites in the endometrium during blastocyst implantation].

    Science.gov (United States)

    Bernal, A; Calzada, L; Hicks, J J; Velázquez, A

    1989-04-01

    The properties of type I and occupied and unoccupied type II cytosolic estrogen binding sites in the rat endometrium were analyzed on day five of pregnancy; the samples studied correspond to blastocyst receptive endometrium (implantation sites), nonreceptive endometrium and ovariectomized uterine horn endometrium, from the same pregnancy rats. The occupied binding site type II was analyzed by exchange assays. Dissociation constant obtained from experiments carried out at 4 or 25 degrees C are similar for each one of the binding site at the three different endometrium samples; the binding capacity (femtomoles/mg protein) from the sites type I and type II and the ratio between occupied (by endogenous estradiol) and unoccupied site type II, seems to be characteristic for each one of the three analyzed endometrium.

  3. Gel-type autologous chondrocyte (Chondron™ implantation for treatment of articular cartilage defects of the knee

    Directory of Open Access Journals (Sweden)

    Chun Chung-Woo

    2010-05-01

    Full Text Available Abstract Background Gel-type autologous chondrocyte (Chondron™ implantations have been used for several years without using periosteum or membrane. This study involves evaluations of the clinical results of Chondron™ at many clinical centers at various time points during the postoperative patient follow-up. Methods Data from 98 patients with articular cartilage injury of the knee joint and who underwent Chondron™ implantation at ten Korean hospitals between January 2005 and November 2008, were included and were divided into two groups based on the patient follow-up period, i.e. 13~24-month follow-up and greater than 25-month follow-up. The telephone Knee Society Score obtained during telephone interviews with patients, was used as the evaluation tool. Results On the tKSS-A (telephone Knee Society Score-A, the score improved from 43.52 ± 20.20 to 89.71 ± 13.69 (P Conclusion Gel-type autologous chondrocyte implantation for chondral knee defects appears to be a safe and effective method for both decreasing pain and improving knee function.

  4. Clinical outcome of a nonsurgical and surgical treatment protocol in different types of peri-implantitis: a case series.

    Science.gov (United States)

    Thierbach, René; Eger, Thomas

    2013-02-01

    The replacement of missing teeth with dental implants has been standard practice in dentistry for many years. The success of dental implants depends on many factors, among which the diagnosis, clinical severity, and treatment of peri-implant diseases play a key role. In this prospective case series, the influence of cumulative treatment modalities on peri-implantitis with and without pus formation on clinical outcome was assessed. During 2010, 28 patients were referred for peri-implantitis treatment. They presented two different types of peri-implant diseases: peri-implantitis with (17 implants) or without pus formation (33 implants). After microbiologic diagnosis, all patients were treated at baseline with full-mouth scaling and root planing. Two months later, further full-mouth scaling and root planing and additional antimicrobial photodynamic therapy (aPDT) was applied. Four months after baseline, patients with pus formation additionally underwent access flap surgery. Active human matrix metalloproteinase-8 (aMMP-8) levels were measured in eluates before and after all treatment modalities and 7 months after baseline. Clinical parameters (probing depth, bleeding on probing) and aMMP-8-levels improved in both groups after treatment and the final examination. In periimplantitis patients without pus formation, all parameters decreased after full-mouth scaling and root planing and the additional aPDT and no surgery was necessary to improve the parameters. In patients with pus formation, the parameters decreased only after access flap surgery. The presence of pus influences the clinical outcome of the treatment of peri-implant diseases. Whereas peri-implantitis cases without pus formation can be successfully managed nonsurgically, peri-implantitis with pus formation can be effectively treated after an additional observation time of 3 months postoperatively only with additional flap surgery.

  5. Hot hardness characteristics of ausformed AISI M-50, Matrix 2, WD-65, modified AISI 440-C, and Super Nitralloy

    Science.gov (United States)

    Chevalier, J. L.; Dietrich, M. W.; Zaretsky, E. V.

    1973-01-01

    Short-term hot hardness studies were performed with ausformed AISI M-50, Matrix 2, WD-65, modified AISI 440-C (14-4-1) and case hardened Super Nitralloy. Hardness levels of each material were measured at elevated temperatures in an electric furnace with a low oxygen environment. Test temperatures ranged from 294 to 877 K. The hot hardness characteristics of the ausformed AISI-M-50, Matrix 2 WD-65, and modified AISI 440-C were the same as those determined for high-speed tool steels. Hot hardness for these steels can be predicted within one point Rockwell C. The hot hardness characteristics of both the case and core of Super Nitralloy were superior to AISI 52100 but inferior to the high-speed tool steels. The short-term Rockwell C hardness at temperature for the Super Nitralloy material between 294 and 769 K can be predicted within one point Rockwell C hardness.

  6. Linear friction welding of AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Bhamji, Imran, E-mail: imran.bhamji@postgrad.manchester.ac.uk [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Preuss, Michael [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Threadgill, Philip L. [Formerly with TWI Ltd., Cambridge, UK (now retired) (United Kingdom); Moat, Richard J. [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Addison, Adrian C. [TWI Ltd., Cambridge (United Kingdom); Peel, Matthew J. [University of Bristol, Queens Building, University Walk, Bristol BS8 1TR (United Kingdom)

    2010-12-15

    Research highlights: {yields} Linear friction welding is a feasible process for joining AISI316L. {yields} Most welds had tensile strengths superior to the parent material. {yields} Welding parameters had a significant impact on weld microstructure. {yields} Control of microstructure by controlling welding parameters is a process benefit. - Abstract: Linear friction welding is a solid state joining process established as a niche technology for the joining of aeroengine bladed disks. However, the process is not limited to this application, and therefore the feasibility of joining a common engineering austenitic steel, AISI 316L, has been explored. It was found that mechanically sound linear friction welds could be produced in 316L, with tensile properties in most welds exceeding those of the parent material. The mechanical properties of the welds were also found to be insensitive to relatively large changes in welding parameters. Texture was investigated in one weld using high energy synchrotron X-ray diffraction. Results showed a strong {l_brace}1 1 1{r_brace}< 1 1 2 > type texture at the centre of the weld, which is a typical shear texture in face centre cubic materials. Variations in welding parameters were seen to have a significant impact on the microstructures of welds. This was particularly evident in the variation of the fraction of delta ferrite, in the thermo-mechanically affected zone of the welds, with different process parameters. Analysis of the variation in delta ferrite, with different welding parameters, has produced some interesting insights into heat generation and dissipation during the process. It is hoped that a greater understanding of the process could help to make the parameter optimisation process, when welding 316L as well as other materials, more efficient.

  7. Extended X-Ray Absorption Fine Structure Investigation of Carbon Stabilized Expanded Austenite and Carbides in Stainless Steel AISI 316

    DEFF Research Database (Denmark)

    Oddershede, Jette; Christiansen, Thomas; Ståhl, Kenny;

    2011-01-01

    Low temperature carburized AISI 316 stainless steel - carbon expanded austenite - was investigated with EXAFS and synchrotron diffraction together with synthesized carbides of the type M3C2, M7C3 and M23C6. It was found that the chemical environment of carbon expanded austenite is not associated ...

  8. Collection efficiency and charge transfer optimization for a 4-T pixel with multi n-type implants

    Institute of Scientific and Technical Information of China (English)

    Li Weiping; Xu Jiangtao; Xu Chao; Li Binqiao; Yao Suying

    2011-01-01

    In order to increase collection efficiency and eliminate image lag,multi n-type implants were introduced into the process of a pinned-photodiode.For the purpose of improving the collection efficiency,multi n-type implants with different implant energies were proposed,which expanded the vertical collection region.To reduce the image lag,a horizontal gradient doping concentration eliminating the potential barrier was also formed by multi n-type implants.The simulation result shows that the collection efficiency can be improved by about 10% in the long wavelength range and the density of the residual charge is reduced from 2.59 × 109 to 2.62 × 107 cm-3.

  9. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  10. Structural and electrical characterizations of n-type implanted layers and ohmic contacts on 3C-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Song, X., E-mail: xi.song@st.com [Universite Francois Rabelais, Tours, LMP, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); STMicroelectronics, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); Biscarrat, J. [Universite Francois Rabelais, Tours, LMP, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); STMicroelectronics, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); Michaud, J.-F.; Cayrel, F. [Universite Francois Rabelais, Tours, LMP, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); Zielinski, M.; Chassagne, T. [NOVASiC, Savoie Technolac, Arche bat 4, BP 267, 73375 Le Bourget du Lac Cedex (France); Portail, M. [Centre de Recherche sur l' Hetero-Epitaxie et ses Applications CNRS, rue Bernard Gregory, 06560 Valbonne (France); Collard, E. [STMicroelectronics, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France); Alquier, D. [Universite Francois Rabelais, Tours, LMP, 16, rue Pierre et Marie Curie, BP 7155, 37071 Tours Cedex 2 (France)

    2011-09-15

    temperature, a doping activation close to 100% has been evaluated by quantitative SSRM technique which evidences that an efficient dopant activation could be done. The high activation rate obtained on n-type implanted 3C-SiC and the low specific contact resistance achieved with Ti/Ni are very promising for electronic device fabrication.

  11. Dental implants as Treatment Option in Patients With Osteopenic Syndrome and Type II Diabetes

    Directory of Open Access Journals (Sweden)

    M.V. Kozlova

    2009-06-01

    Full Text Available One of the important problems in modern dentistry is the study of jaw bone changes associated with type II diabetes. The aim of this study is to evaluate the influence of osteopenic syndrome on osseointegration when using dental implants in patients with type II diabetes. 40 patients with type II diabetes have been evaluated and assigned to two different groups based on the duration of the disease. Including criteria in patients with compensated diabetes were fasting glucose test results <6 mM/l and glycohemoglobin concentration ≤6%. All patients have been evaluated by means of dual energy X-ray absorptiometry on Discovery W densitometer by HOLOGIC. Laboratory blood markers have been used to assess the rate of metabolic processes. 43 implants have been fixed in both groups and maxillary sinus lifting has been applied in 4 cases. No immediate or late post -operative complications have been registered. In cases of disease duration over 5 years and presence of osteopenia the period of surgical wound healing has been prolongated.

  12. Mechanical and Microstructural Properties of Friction Welded AISI 304 Stainless Steel to AISI 1060 Steel AISI 1060

    Directory of Open Access Journals (Sweden)

    Ates H.

    2014-10-01

    Full Text Available Rotary Friction welding is one of the most popular methods of joining similar and dissimilar materials. It is widely used with metals and thermoplastics in a wide variety of aviation, transport and aerospace industrial component designs. This study investigates the influence of friction and upsetting pressures on the hardness, tensile properties and microstructure of the welds. The experimental results showed that as the friction and upsetting pressures increased, the hardness and tensile strength values increased, as well. The tensile fracture of welded joint occurred in the AISI 1060 side. The friction processed joints were evaluated for their integrity and quality aspects by optical and scanning electron microscopy. For the perfect interfacial bonding, sufficient upsetting and friction pressures are necessary to reach the optimal temperature and severe plastic deformation to bring these materials within the attraction range.

  13. Metallurgical and Mechanical Research on Dissimilar Electron Beam Welding of AISI 316L and AISI 4340

    Directory of Open Access Journals (Sweden)

    A. R. Sufizadeh

    2016-01-01

    Full Text Available Dissimilar electron beam welding of 316L austenitic stainless steel and AISI 4340 low alloy high strength steel has been studied. Studies are focused on effect of beam current on weld geometry, optical and scanning electron microscopy, X-ray diffraction of the weld microstructures, and heat affected zone. The results showed that the increase of beam current led to increasing depths and widths of the welds. The optimum beam current was 2.8 mA which shows full penetration with minimum width. The cooling rates were calculated for optimum sample by measuring secondary dendrite arm space and the results show that high cooling rates lead to austenitic microstructure. Moreover, the metallography result shows the columnar and equiaxed austenitic microstructures in weld zone. A comparison of HAZ widths depicts the wider HAZ in the 316L side. The tensile tests results showed that the optimum sample fractured from base metal in AISI 316L side with the UTS values is much greater than the other samples. Moreover, the fractography study presents the weld cross sections with dimples resembling ductile fracture. The hardness results showed that the increase of the beam current led to the formation of a wide softening zone as HAZ in AISI 4340 side.

  14. The Influence of Implant Abutment Surface Roughness and the Type of Cement on Retention of Implant Supported Crowns

    Science.gov (United States)

    Reddy, M. Sushender; Reddy, C. Rajaneesh; Pithani, Padmaja; R, Santosh Kumar; Kulkarni, Ganesh

    2015-01-01

    Objectives: To provide relative data on the retentive characters of the commonly used cements on different implant abutment surfaces. Materials and Methods: A total of 20 implant abutments were divided into 2 groups. Ten implants were unaltered and ten were air borne particle abraded with 50μ aluminium oxide. Three luting agents (Tempbond, IRM and ImProv) were used to secure the crowns to abutments. All the crowns were removed from the abutment with an Instron machine at 0.5mm per minute and tensile bond strengths were recorded. Statistical analysis was performed using Anova, Paired t-test and Post-Hoc tests. Results: IRM showed the highest mean tensile strength among the three cements when used with treated and untreated implant abutment surfaces. Change in the abutment surface roughness had no effect on the mean tensile bond strength of TempBond and IRM cements, whereas ImProv cement showed reduced tensile strength with sandblasted surface. Conclusion: When increased retention is required IRM cement with either sandblasted or milled surface could be used and when retrievability is required cements of choice could be either TempBond or ImProv. PMID:25954694

  15. Collagen type-I leads to in vivo matrix mineralization and secondary stabilization of Mg-Zr-Ca alloy implants.

    Science.gov (United States)

    Mushahary, Dolly; Wen, Cuie; Kumar, Jerald Mahesh; Lin, Jixing; Harishankar, Nemani; Hodgson, Peter; Pande, Gopal; Li, Yuncang

    2014-10-01

    Biodegradable magnesium-zirconia-calcium (Mg-Zr-Ca) alloy implants were coated with Collagen type-I (Coll-I) and assessed for their rate and efficacy of bone mineralization and implant stabilization. The phases, microstructure and mechanical properties of these alloys were analyzed using X-ray diffraction (XRD), optical microscopy and compression test, respectively, and the corrosion behavior was established by their hydrogen production rate in simulated body fluid (SBF). Coll-I extracted from rat tail, and characterized using fourier transform infrared (FT-IR) spectroscopy, was used for dip-coating the Mg-based alloys. The coated alloys were implanted into the femur bones of male New Zealand white rabbits. In vivo bone formation around the implants was quantified by measuring the bone mineral content/density (BMC/BMD) using dual-energy X-ray absorptiometry (DXA). Osseointegration of the implant and new bone mineralization was visualized by histological and immunohistochemical analysis. Upon surface coating with Coll-I, these alloys demonstrated high surface energy showing enhanced performance as an implant material that is suitable for rapid and efficient new bone tissue induction with optimal mineral content and cellular properties. The results demonstrate that Coll-I coated Mg-Zr-Ca alloys have a tendency to form superior trabecular bone structure with better osteoinduction around the implants and higher implant secondary stabilization, through the phenomenon of contact osteogenesis, compared to the control and uncoated ones in shorter periods of implantation. Hence, Coll-I surface coating of Mg-Zr-Ca alloys is a promising method for expediting new bone formation in vivo and enhancing osseointegration in load bearing implant applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Finite element analysis on influence of implant surface treatments, connection and bone types.

    Science.gov (United States)

    Santiago Junior, Joel Ferreira; Verri, Fellippo Ramos; Almeida, Daniel Augusto de Faria; de Souza Batista, Victor Eduardo; Lemos, Cleidiel Aparecido Araujo; Pellizzer, Eduardo Piza

    2016-06-01

    The aim of this study is to assess the effect of different dental implant designs, bone type, loading, and surface treatment on the stress distribution around the implant by using the 3D finite-element method. Twelve 3D models were developed with Invesalius 3.0, Rhinoceros 4.0, and Solidworks 2010 software. The analysis was processed using the FEMAP 10.2 and NeiNastran 10.0 software. The applied oblique forces were 200 N and 100 N. The results were analyzed using maps of maximum principal stress and bone microstrain. Statistical analysis was performed using ANOVA and Tukey's test. The results showed that the Morse taper design was most efficient in terms of its distribution of stresses (p0.05). The different bone types did not show a significant difference in the stress/strain distribution (p>0.05). The surface treatment increased areas of stress concentration under axial loading (p<0.05) and increased areas of microstrain under axial and oblique loading (p<0.05) on the cortical bone. The Morse taper design behaved better biomechanically in relation to the bone tissue. The treated surface increased areas of stress and strain on the cortical bone tissue.

  17. Application of direct laser metal tooling for AISI H13 tool steel

    Institute of Scientific and Technical Information of China (English)

    Jae-Ho LEE; Jeong-Hwan JANG; Byeong-Don JOO; Hong-Sup YIM; Young-Hoon MOON

    2009-01-01

    In the die industry, it is commonly agreed that residual tool life can be successfully extended by timely repair of damaged surfaces. Traditionally, the main repair process is tungsten inert gas (TIG) welding, but a new process called direct laser metal tooling (DLMT) emerges. DLMT is a manual process, of which results depend on the materials of the powders and tools, the laser process and parameters. This technology is a direct-metal freeform fabrication technique in which a 200 W fiber laser is used. AISI H13 tool steel is a suitable material for die casting tools because of the high resistance to thermal fatigue and dimensional stability. In this research, AISI HI3 tool steel was melted with metal powder by fiber laser. Before melting AISI H13, the powders were analyzed with XRF equipment. Then, hardness distribution of laser melted zone was investigated. The microstructure in laser melted zone was discussed. In order to identify the effect of particle size of powder on the melted zone, two types of particle sizes of powders were used. Experimental results show that the mold repair process using DLMT can be applied in the mold repair industry.

  18. Design of Floating Mass Type Piezoelectric Actuator for Implantable Middle Ear Hearing Devices

    Institute of Scientific and Technical Information of China (English)

    LIU Houguang; TA Na; MING Xiaofeng; RAO Zhushi

    2009-01-01

    To overcome some of the problems inherent in conventional hearing aids such as low gain at high frequencies due to acoustic feedback, discomfort in occlusion of the external ear canal and so on, implantable middle ear hearing devices (IMEHDs) have been developed over the past two decades. For such kinds of IMEHDS, this paper presents the design of a floating mass piezoelectric actuator using a PMN-30%PT stack as a new type of vibrator. The proposed piezoelectric actuator consists of only three components of a piezoelectric stack, a metal case and a clamp. For the purpose of aiding the design of this actuator, a coupling biomechanics model of human middle ear and the piezoelectric actuator was constructed. This model was built based on a complete set of computerized tomography section images of a healthy volunteer's left ear by reverse engineering technology. The validity of this model was confirmed by comparing the motion of the tympanic membrane and stapes footplate obtained by this model with published experimental measurements on human temporal bones. It is shown that the designed actuator can be implanted on the incus long process by a simple surgical operation, and the stapes footplate displacement by its excitation at 10.5 V root-mean-square(RMS) voltage was equivalent to that from acoustic stimulation at 100 dB sound pressure level(SPL), which is adequate stimulation to the nssicular chain. The corresponding power consumption is 0.04 mW per volt of excitation at 1 kHz, which is low enough for the transducer to be used in an implantable middle ear device.

  19. Surface fatigue life and failure characteristics of EX-53, CBS 1000M, and AISI 9310 gear materials

    Science.gov (United States)

    Townsend, D. P.

    1985-01-01

    Spur gear endurance tests and rolling-element surface fatigue tests are conducted to investigate EX-53 and CBS 1000M steels for use as advanced application gear materials, to determine their endurance characteristics, and to compare the results with the standard AISI 9310 gear material. The gear pitch diameter is 8.89 cm (3.50 in). Gear test conditions are an oil inlet temperature of 320 K (116 F), an oil outlet temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. Bench-type rolling-element fatigue tests are conducted at ambient temperature with a bar specimen speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPa (700 ksi). The EX-53 test gears have a surface fatigue life of twice that of the AISI 9310 spur gears. The CBS 1000M test gears have a surface fatigue life of more than twice that of the AISI 9310 spur gears. However, the CBS 1000M gears experience a 30-percent tooth fracture failure which limits its use as a gear material. The rolling-contact fatigue lines of RC bar specimens of EX-53 and ASISI 9310 are approximately equal. However, the CBS 1000M RC specimens have a surface fatigue life of about 50 percent that of the AISI 9310.

  20. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses.

    Science.gov (United States)

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; de Faria Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Lemos, Cleidiel Aparecido Araujo; Pellizzer, Eduardo Piza; Santiago, Joel Ferreira

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P<0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P<0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Study on tempering behaviour of AISI 410 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Gopa, E-mail: gopa_mjs@igcar.gov.in [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Das, C.R.; Albert, S.K.; Bhaduri, A.K.; Thomas Paul, V. [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Panneerselvam, G. [Chemistry Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Dasgupta, Arup [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India)

    2015-02-15

    Martensitic stainless steels find extensive applications due to their optimum combination of strength, hardness and wear-resistance in tempered condition. However, this class of steels is susceptible to embrittlement during tempering if it is carried out in a specific temperature range resulting in significant reduction in toughness. Embrittlement of as-normalised AISI 410 martensitic stainless steel, subjected to tempering treatment in the temperature range of 673–923 K was studied using Charpy impact tests followed by metallurgical investigations using field emission scanning electron and transmission electron microscopes. Carbides precipitated during tempering were extracted by electrochemical dissolution of the matrix and identified by X-ray diffraction. Studies indicated that temper embrittlement is highest when the steel is tempered at 823 K. Mostly iron rich carbides are present in the steel subjected to tempering at low temperatures of around 723 K, whereas chromium rich carbides (M{sub 23}C{sub 6}) dominate precipitation at high temperature tempering. The range 773–823 K is the transition temperature range for the precipitates, with both Fe{sub 2}C and M{sub 23}C{sub 6} types of carbides coexisting in the material. The nucleation of Fe{sub 2}C within the martensite lath, during low temperature tempering, has a definite role in the embrittlement of this steel. Embrittlement is not observed at high temperature tempering because of precipitation of M{sub 23}C{sub 6} carbides, instead of Fe{sub 2}C, preferentially along the lath and prior austenite boundaries. Segregation of S and P, which is widely reported as one of the causes for temper embrittlement, could not be detected in the material even through Auger electron spectroscopy studies. - Highlights: • Tempering behaviour of AISI 410 steel is studied within 673–923 K temperature range. • Temperature regime of maximum embrittlement is identified as 773–848 K. • Results show that type of

  2. Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

    Science.gov (United States)

    Meisberger, Eric W; Bakker, Sjoerd J G; Cune, Marco S

    2015-12-01

    Ultrasonic instrumentation under magnification may facilitate mobilization of screw remnants but may induce heat trauma to surrounding bone. An increase of 5°C is considered detrimental to osseointegration. The objective of this investigation was to examine the rise in temperature of the outer implant body after 30 s of ultrasonic instrumentation to the inner part, in relation to implant type, type of ultrasonic equipment, and the use of coolants in vitro. Two ultrasonic devices (Satelec Suprasson T Max and Electro Medical Systems (EMS) miniMaster) were used on five different implant types that were provided with a thermo couple (Astra 3.5 mm, bone level Regular CrossFit (RC) 4.1 mm, bone level Narrow CrossFit (NC) 3.3 mm, Straumann tissue level regular body regular neck 3.3 mm, and Straumann tissue level wide body regular neck 4.8 mm), either with or without cooling during 30 s. Temperature rise at this point in time is the primary outcome measure. In addition, the mean maximum rise in temperature (all implants combined) was assessed and statistically compared among devices, implant systems, and cooling mode (independent t-tests, ANOVA, and post hoc analysis). The Satelec device without cooling induces the highest temperature change of up to 13°C, particularly in both bone level implants (p < 0.05) but appears safe for approximately 10 s of continuous instrumentation, after which a cooling down period is rational. Cooling is effective for both devices. However, when the Satelec device is used with coolant for a longer period of time, a rise in temperature must be anticipated after cessation of instrumentation, and post-operational cooling is advised. The in vitro setup used in this experiment implies that care should be taken when translating the observations to clinical recommendations, but it is carefully suggested that the EMS device causes limited rise in temperature, even without coolant.

  3. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  4. Assessment of SAR and thermal changes near a cochlear implant system for mobile phone type exposures.

    Science.gov (United States)

    McIntosh, Robert L; Iskra, Steve; McKenzie, Raymond J; Chambers, John; Metzenthen, Bill; Anderson, Vitas

    2008-01-01

    A cochlear implant system is a device used to enable hearing in people with severe hearing loss and consists of an internal implant and external speech processor. This study considers the effect of scattered radiofrequency fields when these persons are subject to mobile phone type exposure. A worst-case scenario is considered where the antenna is operating at nominal full power, the speech processor is situated behind the ear using a metallic hook, and the antenna is adjacent to the hook and the internal ball electrode. The resultant energy deposition and thermal changes were determined through numerical modelling. With a 900 MHz half-wave dipole antenna producing continuous-wave (CW) 250 mW power, the maximum 10 g averaged SAR was 1.31 W/kg which occurred in the vicinity of the hook and the ball electrode. The maximum temperature increase was 0.33 degrees C in skin adjacent to the hook. For the 1800 MHz antenna, operating at 125 mW, the maximum 10 g averaged SAR was 0.93 W/kg in the pinna whilst the maximum temperature change was 0.16 degrees C. The analysis predicts that the wearer complies with the radiofrequency safety limits specified by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the Institute of Electrical and Electronics Engineers (IEEE), and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for 900 and 1800 MHz mobile phone type exposure and thus raises no cause for concern. The resultant temperature increase is well below the maximum rise of 1 degrees C recommended by ICNIRP. Effects in the cochlea were insignificant.

  5. Dental implant placement in type II diabetics: a review of the literature.

    Science.gov (United States)

    Courtney, Michael W; Snider, Taylor N; Cottrell, David A

    2010-01-01

    Diabetes mellitus was once considered a contraindication to the use of dental implant therapy as it has been associated with comorbidities, including increased susceptibility to infection, impaired wound healing, and periodontitis. Since dental implants and techniques for controlling diabetes have evolved, dental implant therapy has become increasingly common among patients with diabetes. The rising success of dental implants, along with the realized benefits of implant therapy has shifted current trends to accommodate patients with controlled diabetes as good candidates for treatment. The literature currently suggests that successful treatment results can be attained when placing implants on carefully selected patients with glycosylated hemoglobin levels (HbA1C) less than 8 percent and with possible prophylactic antibiotic administration. This review aims to compile and critically evaluate the current literature for placement of dental implants in patients with diabetes.

  6. A comparision of two types of decalcified freeze-dried bone allograft in treatment of dehiscence defects around implants in dogs

    Directory of Open Access Journals (Sweden)

    Ahmad Moghareh Abed

    2011-01-01

    Full Text Available Background: Decalcified freeze-dried bone allograft (DFDBA may have the potential to enhance bone formation around dental implants. Our aim in this study was the evaluation and comparison of two types of DFDBA in treatment of dehiscence defects around Euroteknika® implants in dogs. Methods : In this prospective clinical trial animal study, all mandibular premolars of three Iranian dogs were extracted. After 3 months of healing, fifteen SLA type Euroteknika® dental implants (Natea with 4.1mm diameter and 10mm length were placed in osteotomy sites with dehiscence defects of 5mm length, 4 mm width, and 3mm depth. Guided bone regeneration (GBR procedures were performed using Cenobone and collagen membrane for six implants, the other six implants received Dembone and collagen membrane and the final three implants received only collagen membrane. All implants were submerged. After 4 months of healing, implants were uncovered and stability (Implant Stability Quotient of all implants was measured. Then, block biopsies of each implant site were taken and processed for ground sectioning and histomorphometric analysis. The data was analyzed by ANOVA and Pearson tests. P value less than 0.05 was considered to be significant. Results: All implants osseointegrated after 4 months. The mean values of bone to implant contact for histomorphometric measurements of Cenobone, Denobone, and control groups were 77.36 ± 9.96%, 78.91 ± 11.9% and 71.56 ± 5.61% respectively, with no significant differences among the various treatment groups. The correlation of Implant Stability Quotient and histomorphometric techniques was 0.692. Conclusion: In treating of dehiscence defects with GBR technique in this study, adding DFDBA did not significantly enhance the percentages of bone-to-implant contact measurements; and Implant Stability Quotient Resonance Frequency Analysis appeared to be a precise technique.

  7. Implementation of a direct install 3-pole type EM transducer in round window niche for implantable middle ear hearing aids.

    Science.gov (United States)

    Shin, Dong Ho; Lim, Hyung-Gyu; Jung, Eui Sung; Wei, Qun; Seong, Ki Woong; Lee, Jyung Hyun; Lee, Seung-Ha; Cho, Jin Ho

    2014-01-01

    Since the 1980's, various types of implantable hearing aids using unique means for delivering acoustic power to the inner ear have been developed. Recently, implantable hearing aids that stimulate the round window by the middle ear transducer have received great attention because it reduces loading effect at the ossicular chain. In this study, we have implemented a direct install 3-pole type EM transducer in round window niche for implantable middle ear hearing aid. The 3-pole type EM transducer consists of two permanent magnets and three coils and exhibit structural features that minimize leakage flux, thereby permitting high efficiency and low magnetic field interference. The stapes velocity was measured using a laser Doppler vibrometer in response to the round window stimulation from the transducer. To verify the usefulness of the 3-pole type EM transducer, we compared the stapes vibration characteristics produced by the transducer and those from a sound source. The magnitude of stapes velocity due to the round window stimulation at 1 mArms was equivalent to that of stapes velocity at 94 dB SPL sound stimulation. Thus, the evaluation study shows that the 3-pole type EM transducer is suitable for implantable hearing devices.

  8. Reduction of deep levels generated by ion implantation into n- and p-type 4H-SiC

    Science.gov (United States)

    Kawahara, Koutarou; Suda, Jun; Pensl, Gerhard; Kimoto, Tsunenobu

    2010-08-01

    The authors have investigated effects of thermal oxidation on deep levels in the whole energy range of the band gap of 4H-SiC by deep level transient spectroscopy. The deep levels are generated by ion implantation. The dominant defects in n-type samples after ion implantation and high-temperature annealing at 1700 °C are IN3 (Z1/2: EC-0.63 eV) and IN9 (EH6/7: EC-1.5 eV) in low-dose-implanted samples, and IN8 (EC-1.2 eV) in high-dose-implanted samples. These defects can remarkably be reduced by thermal oxidation at 1150 °C. In p-type samples, however, IP8 (HK4: EV+1.4 eV) survives and additional defects such as IP4 (HK0: EV+0.72 eV) appear after thermal oxidation in low-dose-implanted samples. In high-dose-implanted p-type samples, three dominant levels, IP5 (HK2: EV+0.85 eV), IP6 (EV+1.0 eV), and IP7 (HK3: EV+1.3 eV), are remarkably reduced by oxidation at 1150 °C. The dominant defect IP4 observed in p-type 4H-SiC after thermal oxidation can be reduced by subsequent annealing in Ar at 1400 °C. These phenomena are explained by a model that excess interstitials are generated at the oxidizing interface, which diffuse into the bulk region.

  9. The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

    Science.gov (United States)

    2017-01-01

    PURPOSE The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anteriorposterior direction of dislodging force (P <.05). CONCLUSION Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force. PMID:28243387

  10. Adhesion of composite carbon/hydroxyapatite coatings on AISI 316L medical steel

    Directory of Open Access Journals (Sweden)

    J. Gawroński

    2009-07-01

    Full Text Available In this paper are contains the results of studies concerning the problems associated with increased of hydroxyapatite (HAp adhesion, manufactured by using Pulse Laser Deposition (PLD method, to the austenitic steel (AISI 316L through the coating of carbon interlayer on it. Carbon coating was deposited by Radio Frequency Plasma Assisted Chemical Vapour Deposition (RF PACVD method.Test results unequivocally showed that the intermediate carbon layer in a determined manner increase the adhesion of hydroxyapatite to the metallic substrate. Obtained results give rise to deal with issues of manufacturing composite bilayer – carbon film/HAp – on ready implants, casted from austenitic cast steel by lost-wax process method as well as in gypsum forms.

  11. An investigation of the aseptic loosening of an AISI 316L stainless steel hip prosthesis.

    Science.gov (United States)

    Godec, Matjaz; Kocijan, Aleksandra; Dolinar, Drago; Mandrino, Djordje; Jenko, Monika; Antolic, Vane

    2010-08-01

    The total replacement of joints by the implantation of permanently indwelling prosthetic components has been one of the major successes of modern surgery in terms of relieving pain and correcting deformity. However, the aseptic loosening of a prosthetic-joint component is the most common reason for joint-revision surgery. Furthermore, it is thought that wear particles are one of the major contributors to the development and perpetuation of aseptic loosening. The aim of the present study was to identify the factors related to the aseptic loosening of an AISI 316L stainless steel total hip prosthesis. The stem was evaluated by x-ray photoelectron spectroscopy, with polished and rough regions being analyzed in order to establish the differences in the chemical compositions of both regions. Specific areas were examined using scanning electron microscopy with energy dispersive x-ray spectroscopy and light microscopy.

  12. Fretting fatigue in AISI 1015 steel

    Indian Academy of Sciences (India)

    R Gnanamoorthy; R Rosi Reddy

    2002-04-01

    A small osillatory movement between two contacting surfaces is termed as fretting and on many occasions it acts as the crack initiation site leading to catastrophic failure of the overall structure. The occurrence of fretting is observed in many engineering structures such as shaft flanges, gas turbines, steel ropes etc. An experimental facility, which can simulate the fretting fatigue in many engineering applications, is the primary requirement of the research program. A laboratory fretting fatigue test facility capable of varying many influencing parameters of fretting fatigue such as slip amplitutde, frequency, contact pressure, etc is designed and developed. Preliminary investigations on plain and fretting fatigue behaviour of AISI 1015 structural steel are reported in this paper. A strength reduction factor of about 1.30 was obtained due to fretting for the test material under the present experimental conditions. Influence of contact load on fretting was also studied. Increasing fretting contact load decreased the fatigue life in the range investigated. Failure analysis showed typical stage I oblique crack growth followed by stage II straight crack perpedicular to the fretting zone.

  13. Optimization of tensile strength of friction welded AISI 1040 and AISI 304L steels according to statistics analysis (ANOVA)

    Energy Technology Data Exchange (ETDEWEB)

    Kirik, Ihsan [Batman Univ. (Turkey); Ozdemir, Niyazi; Firat, Emrah Hanifi; Caligulu, Ugur [Firat Univ., Elazig (Turkey)

    2013-06-01

    Materials difficult to weld by fusion welding processes can be successfully welded by friction welding. The strength of the friction welded joints is extremely affected by process parameters (rotation speed, friction time, friction pressure, forging time, and forging pressure). In this study, statistical values of tensile strength were investigated in terms of rotation speed, friction time, and friction pressure on the strength behaviours of friction welded AISI 1040 and AISI 304L alloys. Then, the tensile test results were analyzed by analysis of variance (ANOVA) with a confidence level of 95 % to find out whether a statistically significant difference occurs. As a result of this study, the maximum tensile strength is very close, which that of AISI 1040 parent metal of 637 MPa to could be obtained for the joints fabricated under the welding conditions of rotation speed of 1700 rpm, friction pressure of 50 MPa, forging pressure of 100 MPa, friction time of 4 s, and forging time of 2 s. Rotation speed, friction time, and friction pressure on the friction welding of AISI 1040 and AISI 304L alloys were statistically significant regarding tensile strength test values. (orig.)

  14. Solubilization and stabilization Heat treatments influence on the susceptibility to intergranular corrosion in AISI-321 steel. Influencia de los tratamientos termicos de solubilizacion estabilizacion sobre la respuesta a la corrosion integranular del acero AISI-321

    Energy Technology Data Exchange (ETDEWEB)

    Fosca, C.; Salas, R.; Saenz, E.; Otero, E.

    1993-01-01

    The influence of heat treatments on the susceptibility to intergranular corrosion of AISI-321 steel is studied by using the EPR method (Electrochemical Potentiokinetic Reactivation). It is shown that a solubilization treatment at 1.373 K gives the material a better resistance against intergranular attach than higher temperatures treatments. A subsequent stabilization heat treatment at 1.073 K gives the best resistance against this type of corrosion to the studied steel. (Author) 12 refs.

  15. Properties and local environment of p-type and photoluminescent rare earths implanted into ZnO single crystals

    CERN Document Server

    Rita, EMC; Wahl, U; Soares, JC

    This thesis presents an experimental study of the local environment of p-type and Rare- Earth dopants implanted in ZnO single-crystals (SCs). Various nuclear and bulk property techniques were combined in the following evaluations: Implantation damage annealing was evaluated in ZnO SCs implanted with Fe, Sr and Ca. P-type dopants Cu and Ag implanted ZnO SCs were studied revealing that the solubility of Cu in substituting Zn is considerably higher than that of Ag. These results are discussed within the scope of the ZnO p-type doping problematic with these elements. Experimental proofs of the As “anti-site” behavior in ZnO were for the first time attained, i.e., the majority of As atoms are substitutional at the Zn site (SZn), possibly surrounded by two Zn vacancies (VZn). This reinforces the theoretical prediction that As acts as an acceptor in ZnO via the AsZn-2VZn complex formation. The co-doping of ZnO SC with In (donor) and As (acceptor) was addressed. The most striking result is the possible In-As “p...

  16. Osteogenicity of titanium implants coated with calcium phosphate or collagen type-I in osteoporotic rats

    NARCIS (Netherlands)

    Alghamdi, H.S.A.; Bosco, R.; Beucken, J.J. van den; Walboomers, X.F.; Jansen, J.A.

    2013-01-01

    This study hypothesized that modification of titanium implant surface, e.g. by the deposition of inorganic/organic coatings, can significantly improve the implant-bone response compared in osteoporotic vs. healthy conditions. After osteoporosis was induced in 15 female Wistar rats by ovariectomy

  17. Breakdown and Evolution of the Protective Oxide Scales of AISI 304 and AISI 316 Stainless Steels under High-Temperature Oxidation

    Directory of Open Access Journals (Sweden)

    K. A. Habib

    2011-01-01

    Full Text Available The failure of the protective oxide scales of AISI 304 and AISI 316 stainless steels has been studied and compared at 1,000°C in synthetic air. First, the isothermal thermogravimetric curves of both stainless steels were plotted to determine the time needed to reach the breakdown point. The different resistance of each stainless steel was interpreted on the basis of the nature of the crystalline phases formed, the morphology, and the surface structure as well as the cross-section structure of the oxidation products. The weight gain of AISI 304 stainless steel was about 8 times greater than that of AISI 316 stainless steel, and AISI 316 stainless steel reached the breakdown point about 40 times more slowly than AISI 304 stainless steel. In both stainless steels, reaching the breakdown point meant the loss of the protective oxide scale of Cr2O3, but whereas in AISI 304 stainless steel the Cr2O3 scale totally disappeared and exclusively Fe2O3 was formed, in AISI 316 stainless steel some Cr2O3 persisted and Fe3O4 was mainly formed, which means that AISI 316 stainless steel is more resistant to oxidation after the breakdown.

  18. The study on the properties of AISI 4140 and AISI 1040 steel rods welded by friction welding

    OpenAIRE

    Thanee Toomprasen; Chawalit Thinvongpituk; Sukangkana Talangkun

    2014-01-01

    This paper is aimed to investigate the properties of joint between AISI 4140 and AISI 1040 welded by friction welding. The specimens were prepared in round shape of 13 mm diameter and 100 mm long. They were welded by friction welding method under the following conditions; friction pressure of 183 MPa, friction time of 12 sec, upset pressure of 428 MPa, upset time of 7 sec. and rotational speed of 1400 rpm. The strength and hardness were tested on the welded area. The result showed finer grain...

  19. Thermomechanical behaviour of AISI 304 steels; Comportamiento termomecanico de aceros AISI 304

    Energy Technology Data Exchange (ETDEWEB)

    El Wahabi, M.; Garcia, V. G.; Cabrera, J. M.; Prado, J. M.

    2001-07-01

    The hot deformation behaviour of three AISI 304 (H, L and HP) austenitic stainless steel with different carbon contents has been studied. An analysis of the parameters describing their hot flow curves was carried out. No heavy effect of the carbon content was found on most of the latter parameters. However, the work hardening and dynamic recovery behaviour showed clear differences depending on the given alloy, especially at high temperatures and low strain rates where the high carbon steel displayed larger work hardening and dynamic recovery rates than the other steels. The high purity steel (interstitial free) displayed the lower stress levels as its hardening rate was slower than in the other two steels. (Author) 16 refs.

  20. Comparison of the efficacy of different types of lasers for the treatment of peri-implantitis: a systematic review.

    Science.gov (United States)

    Natto, Zuhair S; Aladmawy, Majdi; Levi, Paul A; Wang, Hom-Lay

    2015-01-01

    To evaluate the efficacy of various types of lasers (neodymium-doped yttrium-aluminum-garnet [Nd:YAG], carbon dioxide [CO2], diode, erbium/chromium-doped yttrium-scandium-gallium-garnet [Er,Cr:YSGG], and erbium-doped yttrium-aluminum-garnet [Er:YAG]) in the treatment of peri-implantitis and their use in surgical and nonsurgical procedures. Human studies for the treatment of peri-implantitis with laser therapy, published between 2002 and January 2014, were collected utilizing the electronic databases PubMed, Ovid, MEDLINE, Cochrane, and Google Scholar. Two reviewers conducted the study selection, data collection, and validity assessment. Eight hundred twelve studies were selected in the initial title search; 13 studies were then chosen for this review. No human studies evaluated the effect of the Nd:YAG laser on peri-implantitis. The CO2 laser is reported to be safe and able to enhance bone regeneration. The diode laser (980 nm) seems to be effective in its bactericidal effect without changing the implant surface pattern. The Er,Cr:YSGG laser was reported to obtain bone regeneration around a failing implant in one case, while the Er:YAG laser exhibits a strong bactericidal effect against periodontopathic bacteria at a low energy level. Although lasers have shown promising results in reducing clinical signs of peri-implantitis, because of the limited sample sizes and short follow-up periods, no firm conclusion can be drawn at this moment. Hence, there is a need for more well-designed, longitudinal, randomized controlled clinical trials.

  1. Electrochemical Study of Welded AISI 304 and 904L Stainless Steel in Seawater in View of Corrosion

    Directory of Open Access Journals (Sweden)

    Richárd Székely

    2010-10-01

    Full Text Available This is a comparative study of the corrosion behaviour of welds in AISI 304 and AISI 904L stainless steels carried out in seawater model solution in the temperature range 5-35°C and the standard of corrosion testing of welds was followed. The corrosion rate and corrosion attack characteristics were determined for welds of the examined steels with several type of treatment. The aim of this work was to compare the steels based on their resistance against the corrosion in terms of pitting potential (Epit and repassivation potential (Erepass. Seawater is an electrochemically aggressive medium, which can initiate localised corrosion in welded stainless steels. Different electrochemical and testing methods were used, including cyclic voltammetry, chronopotentiometry, electrochemical impedance spectroscopy (EIS, pH measuring and penetration tests.

  2. Collagen type I coating stimulates bone regeneration and osteointegration of titanium implants in the osteopenic rat

    National Research Council Canada - National Science Library

    Sartori, Maria; Giavaresi, Gianluca; Parrilli, Annapaola; Ferrari, Andrea; Aldini, Nicolò Nicoli; Morra, Marco; Cassinelli, Clara; Bollati, Daniele; Fini, Milena

    2015-01-01

    ...) on bone regeneration and osteointegration in a healthy and osteopenic rat animal model.TiColl screws were implanted into the femoral condyles of healthy and osteopenic rats and compared with acid-etched titanium (Ti) screws...

  3. Identification of vacancy type defects in low and high energy nitrogen ion implanted InP

    Energy Technology Data Exchange (ETDEWEB)

    Santhakumar, K [Department of Nuclear Physics, University of Madras, Chennai - 600025 (India); Rao, G Venugopal [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Amarendra, G [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Abhaya, S [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Sastry, V Sankara [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Nair, K G M [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102 (India); Ravichandran, V [Department of Nuclear Physics, University of Madras, Chennai - 600025 (India)

    2005-12-21

    Depth resolved positron annihilation measurements were carried out on 85 keV and 1 MeV nitrogen ion implanted InP samples. The defect sensitive S-parameter and R-parameter values for the low energy implantations confirm the presence of monovacancies up to a dose of 10{sup 15} cm{sup -2} and coexistence of monovacancies and divacancies for 10{sup 16} cm{sup -2} dose sample. Corroborative glancing incidence x-ray diffraction measurements on the highest dose sample revealed that the sample is amorphized. For high energy implantation, it is found that vacancy-defects are present right from the near-surface region and these defects are identified to be monovancancies, based on the observed S- and R-parameters. A comparison of the results for the low and high energy implantations is made.

  4. Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Denollet, Johan; Tekle, Fetene B; Pedersen, Susanne S.;

    2013-01-01

    Clinical trials have shown the benefit of implantable cardioverter defibrillator (ICD) treatment. In this study, we examined the importance of chronic psychological distress and device shocks among ICD patients seen in clinical practice....

  5. Ion implantation of superhard ceramic cutting tools

    Science.gov (United States)

    Chou, Y. Kevin; Liu, Jie

    2004-08-01

    Despite numerous reports of tool life increase by ion implantation in machining operations, ion implantation applications of cutting tools remain limited, especially for ceramic tools. Mechanisms of tool-life improvement by implantation are not clearly established due to complexity of both implantation and tool-wear processes. In an attempt to improve performance of cubic boron nitride (CBN) tools for hard machining by ion implantation, a literature survey of ion-implanted cutting tools was carried out with a focus on mechanisms of tool-wear reduction by ion implantation. Implantation and machining experiments were then conducted to investigate implantation effects on CBN tools in hard machining. A batch of CBN tools was implanted with nitrogen ions at 150 keV and 2.5×1017 ions/cm2 and further used to cut 61 HRc AISI 52100 steel at different conditions. Results show that ion implantation has strong effects on partsurface finish, moderate effect on cutting forces, but an insignificant impact on tool wear. Friction coefficients, estimated from measured cutting forces, are possibly reduced by ion implantation, which may improve surface finish. However, surprisingly, 2-D orthogonal cutting to evaluate tribological loading in hard machining showed no difference on contact stresses and friction coefficients between implanted and nonimplanted CBN tools.

  6. Laboratory implantation for well type ionization chambers calibration; Implantacao de um laboratorio para calibracao de camaras de ionizacao tipo poco

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, E.A.; Dias, D.J.; Almeida, C.E. de [Laboratorio de Ciencias Radiologicas- LCR- DBB (UERJ). R. Sao Francisco Xavier, 524- Pav. HLC, sala 136 terreo- CEP 20.550-013. Rio de Janeiro (Brazil)

    1998-12-31

    The Radiological Science Laboratory is implanting a service for calibration of well type chambers by IAEA training program. The kerma rate in the air (mu Gy/h) of the linear Cs-137 reference source CDCS-J4 have been determined using a well type chamber Standard Imaging HDR-1000 model, which have been calibrated at Secondary Standard Laboratory Calibration of IAEA, whereas two HDR-1000 Plus chambers were calibrated too, following the same standards. The results were compared with Wisconsin University calibration certification and has demonstrated that well type ionization chamber calibration can be used in brachytherapy for several kinds of radionuclides. (Author)

  7. Few-Layer MoS₂ p-Type Devices Enabled by Selective Doping Using Low Energy Phosphorus Implantation.

    Science.gov (United States)

    Nipane, Ankur; Karmakar, Debjani; Kaushik, Naveen; Karande, Shruti; Lodha, Saurabh

    2016-02-23

    P-type doping of MoS2 has proved to be a significant bottleneck in the realization of fundamental devices such as p-n junction diodes and p-type transistors due to its intrinsic n-type behavior. We report a CMOS compatible, controllable and area selective phosphorus plasma immersion ion implantation (PIII) process for p-type doping of MoS2. Physical characterization using SIMS, AFM, XRD and Raman techniques was used to identify process conditions with reduced lattice defects as well as low surface damage and etching, 4X lower than previous plasma based doping reports for MoS2. A wide range of nondegenerate to degenerate p-type doping is demonstrated in MoS2 field effect transistors exhibiting dominant hole transport. Nearly ideal and air stable, lateral homogeneous p-n junction diodes with a gate-tunable rectification ratio as high as 2 × 10(4) are demonstrated using area selective doping. Comparison of XPS data from unimplanted and implanted MoS2 layers shows a shift of 0.67 eV toward lower binding energies for Mo and S peaks indicating p-type doping. First-principles calculations using density functional theory techniques confirm p-type doping due to charge transfer originating from substitutional as well as physisorbed phosphorus in top few layers of MoS2. Pre-existing sulfur vacancies are shown to enhance the doping level significantly.

  8. The study on the properties of AISI 4140 and AISI 1040 steel rods welded by friction welding

    Directory of Open Access Journals (Sweden)

    Thanee Toomprasen

    2014-06-01

    Full Text Available This paper is aimed to investigate the properties of joint between AISI 4140 and AISI 1040 welded by friction welding. The specimens were prepared in round shape of 13 mm diameter and 100 mm long. They were welded by friction welding method under the following conditions; friction pressure of 183 MPa, friction time of 12 sec, upset pressure of 428 MPa, upset time of 7 sec. and rotational speed of 1400 rpm. The strength and hardness were tested on the welded area. The result showed finer grains. in the welded area. This is the result of friction pressure and upset pressure in the welding process. In addition, the observation result indicated some changes of Ferrite and Pearlite in welded zone. This phase change resulted in the increment of hardness in AISI 4140 at the contact area and adjacent. In part of AISI 1040, the portion of Pearlite and Ferrite are not significantly changed, therefore the value of hardness is almost constant.

  9. Influence of oil and water media on fretting behaviour of AISI 52100 steel rubbing against AISI 1045 steel

    Institute of Scientific and Technical Information of China (English)

    REN Ping-di; CHEN Guang-xiong; ZHU Min-hao; ZHOU Zhong-rong

    2004-01-01

    A series of fretting test were carried out using a DELTA PLINT testing system to study the influence of hydraulic oil and water on fretting behaviour of AISI 52100 steel rubbing against AISI 1045 steel. The test result shows that media hydraulic oil and water have a distinct influence on fretting behaviour of the tested materials. Medium water can lead to shifting of the partial slip regime in the fretting map from a larger displacement amplitude toward a smaller one and enlargement of the mixed slip regime, in comparison with that in ambient atmosphere. While medium hydraulic oil can result in shifting of the partial slip regime from a smaller displacement amplitude toward a larger one. In the gross slip regime, hydraulic oil and water play a positive role as lubrication media. They can clearly decrease the fretting friction coefficient between AISI 52100 and AISI 1045. The test result also demonstrates that this lubrication effect will get better with increasing displacement amplitude and that hydraulic oil is better than water for lubrication. SEM observation of the wear scars displays that the fretting wear mainly results from abrasive wear and delamination of the fretted materials when using these two kinds of substances as lubrication media.

  10. Deformation induced martensite in AISI 316 stainless steel

    Directory of Open Access Journals (Sweden)

    Solomon, N.

    2010-04-01

    Full Text Available The forming process leads to a considerable differentiation of the strain field within the billet, and finally causes the non-uniform distribution of the total strain, microstrusture and properties of the material over the product cross-section. This paper focus on the influence of stress states on the deformation-induced a’ martensitic transformation in AISI Type 316 austenitic stainless steel. The formation of deformation-induced martensite is related to the austenite (g instability at temperatures close or below room temperature. The structural transformation susceptibility is correlated to the stacking fault energy (SFE, which is a function not only of the chemical composition, but also of the testing temperature. Austenitic stainless steels possess high plasticity and can be easily cold formed. However, during cold processing the hardening phenomena always occurs. Nevertheless, the deformation-induced martensite transformation may enhance the rate of work-hardening and it may or may not be in favour of further material processing. Due to their high corrosion resistance and versatile mechanical properties the austenitic stainless steels are used in pressing of heat exchanger plates. However, this corrosion resistance is influenced by the amount of martensite formed during processing. In order to establish the links between total plastic strain, and martensitic transformation, the experimental tests were followed by numerical simulation.

    El proceso de conformación da a lugar a una considerable diferenciación del campo de tensiones dentro de una barra de extrusión y, finalmente, causa una distribución no uniforme de la tensión total, la microestructura y propiedades del material sobre el corte transversal. En este trabajo se estudia la influencia de los estados de tensión sobre la transformación martensítica inducida por deformación en un acero inoxidable austenítico tipo AISI 316. La formación de martensita inducida por

  11. Comportamiento electroquímico de un acero inoxidable AISI 430 implantado con cerio

    Directory of Open Access Journals (Sweden)

    Abreu, C. M.

    2002-10-01

    Full Text Available Chemical treatment in solutions containing cerium compounds has been widely used for prevention of localized corrosion in aluminium alloys (pitting corrosion as well as in stainless steels (crevice corrosion. Ionic implantation presents several advantages for stainless steels. The present paper is devoted to study the effect of cerium implantation on the properties of passive films formed on an AISI 430 stainless steel in alkaline medium. The electrochemical study is performed by cyclic voltammetry and EIS. The chemical characterisation of the oxides film developed is performed by XPS, and the morphological study corresponds to SEM examination. The results show that cerium implantation hinders magnetite formation as well as chromium oxidation processes.

    En los últimos años, se ha extendido el uso de disoluciones de sales de cerio como tratamiento para mejorar la resistencia localizada de las aleaciones de aluminio y para incrementar la resistencia a la corrosión en resquicio de diversos aceros inoxidables. En el caso de estos últimos, la adición de cerio mediante implantación iónica supone notables ventajas con respecto a otros tratamientos. En este artículo se investiga el efecto que ejerce la implantación de cerio sobre la película pasivante de un acero inoxidable ferrítico AISI 430. Para ello, se analiza el comportamiento electroquímico en medio básico mediante la utilización de voltametría cíclica y espectroscopia de impedancia electroquímica. La caracterización química de la película de óxidos formada se realiza mediante XPS, y el estudio morfológico mediante SEM. Los resultados muestran una importante inhibición en la formación de magnetita, así como una reducción en el proceso de oxidación que experimenta el cromo en el acero implantado con cerio.

  12. P-type ZnO films by phosphorus doping using plasma immersion ion-implantation technique

    Science.gov (United States)

    Nagar, S.; Chakrabarti, S.

    2013-03-01

    ZnO has been a subject of intense research in the optoelectronics community owing to its wide bandgap (3.3eV) and large exciton binding energy (60meV). However, difficulty in doping it p-type posts a hindrance in fabricating ZnO-based devices. In order to make p-type ZnO films, phosphorus implantation, using plasma immersion ion-implantation technique (2kV, 900W, 10μs pulse width) for 30 seconds, was performed on ZnO thin film deposited by RF Magnetron Sputtering (Sample A). The implanted samples were subsequently rapid thermal annealed at 700°C and 1000°C (Samples B and C) in oxygen environment for 30 seconds. Low temperature (8K) photoluminescence spectra reveal dominant donor-bound exciton (D°X) peak at 3.36eV for samples A and B. However, for Sample B the peaks around 3.31eV and 3.22eV corresponding to the free electron-acceptor (FA) and donor to acceptor pair peaks (DAP) are also observed. A dominant peak around 3.35eV, corresponding to acceptor bound exciton (A°X) peak, is detected for Sample C along with the presence of FA and DAP peaks around 3.31eV and 3.22eV. Moreover, the deep level peak around 2.5eV is higher for Sample B which may be due to implantation and acceptor related defects. However, for Sample C, the deep level peaks are very weak compared to the near band edge peaks confirming that these peaks are mainly due to intrinsic defects and not related to acceptors. These results clearly show us a promising way to achieve p-type ZnO films using phosphorus doping.

  13. Effect of higher implant density on curve correction in dystrophic thoracic scoliosis secondary to neurofibromatosis Type 1.

    Science.gov (United States)

    Li, Yang; Yuan, Xinxin; Sha, Shifu; Liu, Zhen; Zhu, Weiguo; Qiu, Yong; Wang, Bin; Yu, Yang; Zhu, Zezhang

    2017-10-01

    OBJECTIVE The aim of this study was to investigate how implant density affects radiographic results and clinical outcomes in patients with dystrophic scoliosis secondary to neurofibromatosis Type 1 (NF1). METHODS A total of 41 patients with dystrophic scoliosis secondary to NF1 who underwent 1-stage posterior correction between June 2011 and December 2013 were included. General information about patients was recorded, as were preoperative and postoperative scores from Scoliosis Research Society (SRS)-22 questionnaires. Pearson correlation analysis was used to analyze the associations among implant density, coronal Cobb angle correction rate and correction loss at last follow-up, change of sagittal curve, and apical vertebral translation. Patients were then divided into 2 groups: those with low-density and those with high-density implants. Independent-sample t-tests were used to compare demographic data, radiographic findings, and clinical outcomes before surgery and at last follow-up between the groups. RESULTS Significant correlations were found between the implant density and the coronal correction rate of the main curve (r = 0.505, p density and change of sagittal profile (p = 0.662) or apical vertebral translation (p = 0.062). The SRS-22 scores improved in the appearance, activity, and mental health domains within both groups, but there was no difference between the groups in any of the SRS-22 domains at final follow-up (p > 0.05 for all). CONCLUSIONS Although no significant differences between the high- and low-density groups were found in any of the SRS-22 domains at final follow-up, higher implant density was correlated with superior coronal correction and less postoperative correction loss in patients with dystrophic NF1-associated scoliosis.

  14. The effect of isotope on the dynamic behavior of <1 0 0> vacancy-type dislocation loop in deuterium-implanted Fe

    Energy Technology Data Exchange (ETDEWEB)

    Liu, P.P.; Zhu, Y.M.; Zhao, M.Z.; Jiang, S.N. [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Liu, C.X.; Wang, Y.M. [Faculty of Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Wan, F.R. [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Ohnuki, S. [Faculty of Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Zhan, Q., E-mail: qzhan@mater.ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-06-15

    Highlights: • Vacancy-loop formed in D-implanted Fe after anneal at high temperature. • V-loop formation temperature in D-implanted Fe is higher than that in H-implanted one. • Dynamic behavior of <1 0 0> vacancy-loop in D-implanted Fe has been in situ observed. • Growth and shrink rate of both type loops increase with increase of the damage rate. • The origin for the behavior of both type loops was discussed in detail. - Abstract: The dynamic behavior of individual loops of the both interstitial and vacancy types is believed to be strongly connected to the degradation processes that affect radiation-resistant materials used in nuclear-fission and fusion devices. Meanwhile, the isotopic effect of hydrogen on irradiation damage has attracted wide interest. In situ transmission electron microscopy investigation of the dynamic behavior of dislocation loops under high-energy electron irradiation was carried out in pure Fe with deuterium implantation at room temperature and aged at different temperatures. Shrinkage of dislocation loop was observed in implanted sample annealed at 753 K, except the popular growth of dislocation loop. The loop shrinkage was also observed in H implanted sample annealed at relatively lower temperature. The shrinking loop is identified to be <1 0 0> vacancy-type loop by acknowledged “inside–outside” method. Origin for the dynamic behavior of both type loops and the isotopic effect on the behavior were discussed.

  15. Biomechanical and histological evaluation of the osseointegration capacity of two types of zirconia implant

    Science.gov (United States)

    Han, Jian-min; Hong, Guang; Lin, Hong; Shimizu, Yoshinaka; Wu, Yuhan; Zheng, Gang; Zhang, Hongyu; Sasaki, Keiichi

    2016-01-01

    The purpose of this study was to evaluate the biomechanical and histological behavior of a ceria-stabilized zirconia–alumina nanocomposite (NanoZr) in comparison with that of 3 mol% yttria-stabilized tetragonal zirconia polycrystalline (3Y-TZP) in Sprague Dawley rats. Cylindrical NanoZr and 3Y-TZP implants (diameter 1 mm, length 2 mm) were used. Implant-surface morphology and surface roughness were determined by scanning white-light interferometry and scanning electron microscopy, respectively. The cylindrical zirconia implants were placed at the distal edge of the femur of Sprague Dawley rats. At weeks 2, 4, and 8, the interfacial shear strength between implant and bone was measured by push-in test. Histological analysis was performed using hard-tissue sections. Bone–implant contact (BIC), the thickness of new bone around the implant within the bone marrow area, and osteoclast numbers were evaluated. The average surface roughness of 3Y-TZP (Sa 0.788 μm) was significantly higher than that of NanoZr (Sa 0.559 μm). The shear strengths of 3Y-TZP and NanoZr were similar at 2 weeks, but at 4 and 8 weeks the shear strength of NanoZr was higher than that of 3Y-TZP. The average BIC values within the bone marrow area for 3Y-TZP and NanoZr were 25.26% and 31.51% at 2 weeks, 46.78% and 38% at 4 weeks, and 47.88% and 56.81% at 8 weeks, respectively. The average BIC values within the cortical area were 38.86% and 58.42% at 2 weeks, 66.82% and 57.74% at 4 weeks, and 79.91% and 78.97% at 8 weeks, respectively. The mean BIC value did not differ significantly between the two zirconia materials at any time point. The NanoZr implants were biocompatible, capable of establishing close BIC, and may be preferred for metal-free dental implants. PMID:27994456

  16. Dynamic strain ageing of deformed nitrogen-alloyed AISI 316 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Ehrnsten, U.; Toivonen, A. [Materials and Structural Integrity, VTT Technical Research Centre of Finland, Kemistintie 3, P.O. Box 1704, FIN-02044 VTT (Finland); Ivanchenko, M.; Nevdacha, V.; Yagozinskyy, Y.; Haenninen, H. [Department of Mechanical Engineering, Helsinki University of Technology Puumiehenkuja 3, P.O. Box 4200, FIN-02015 HUT (Finland)

    2004-07-01

    Intergranular stress corrosion cracking has occurred in BWR environment in non-sensitized, deformed austenitic stainless steel materials. The affecting parameters are so far not fully known, but deformation mechanisms may be decisive. The effect of deformation and nitrogen content on the behaviour of austenitic stainless steels was investigated. The materials were austenitic stainless steels of AISI 316L type with different amounts of nitrogen (0.03 - 0.18%) and they were mechanically deformed 0, 5 and 20%. The investigations are focused on the dynamic strain ageing (DSA) behaviour. A few crack growth rate measurements are performed on nuclear grade AISI 316NG material with different degrees of deformation (0, 5 and 20%). The effects of DSA on mechanical properties of these materials are evaluated based on peaks in ultimate tensile strength and strain hardening coefficient and minimum in ductility in the DSA temperature range. Additionally, internal friction measurements have been performed in the temperature range of -100 to 600 deg. C for determining nitrogen interactions with other alloying elements and dislocations (cold-worked samples). The results show an effect of nitrogen on the stainless steel behaviour, e.g. clear indications of dynamic strain ageing and changes in the internal friction peaks as a function of nitrogen content and amount of deformation. (authors)

  17. Improving by postoxidation of corrosion resistance of plasma nitrocarburized AISI 316 stainless steels

    Science.gov (United States)

    Yenilmez, A.; Karakan, M.; Çelik, İ.

    2017-01-01

    Austenitic stainless steels are widely used in several industries such as chemistry, food, health and space due to their perfect corrosion resistance. However, in addition to corrosion resistance, the mechanic and tribological features such as wear resistance and friction are required to be good in the production and engineering of this type of machines, equipment and mechanic parts. In this study, ferritic (FNC) and austenitic (ANC) nitrocarburizing were applied on AISI 316 stainless steel specimens with perfect corrosion resistance in the plasma environment at the definite time (4 h) and constant gas mixture atmosphere. In order to recover corrosion resistance which was deteriorated after nitrocarburizing again, plasma postoxidation process (45 min) was applied. After the duplex treatment, the specimens' structural analyses with XRD and SEM methods, corrosion analysis with polarization method and surface hardness with microhardness method were examined. At the end of the studies, AISI 316 surface hardness of stainless steel increased with nitrocarburizing process, but the corrosion resistance was deteriorated with FNC (570 °C) and ANC (670 °C) nitrocarburizing. With the following of the postoxidation treatment, it was detected that the corrosion resistance became better and it approached its value before the process.

  18. Sustained release of insulin-like growth factor-1 from poly(lactide-co-glycolide) microspheres improves osseointegration of dental implants in type 2 diabetic rats.

    Science.gov (United States)

    Wang, Feng; Song, Ying-liang; Li, Cui-xia; Li, De-hua; Zhang, He-peng; Ma, Ai-jie; Xi, Xiao-qing; Zhang, Ning; Wang, Bao-gang; Wang, Yao; Zhou, Wei

    2010-08-25

    Dental implantation is an effective and predictable treatment modality for replacing missing teeth and repairing maxillofacial defects. However, implants in patients with type 2 diabetes mellitus are likely to have a high failure rate and poor initial osseointegration. In the current study, we established an effective drug delivery system designed to improve osseointegration of dental implants in an animal model of type 2 diabetes. Twenty type 2 diabetic rats were divided into two groups: a group receiving recombinant rat Insulin-like Growth Factor 1 (rrIGF-1) Microsphere Therapy (MST) (10 rats) and a control group (10 rats). The rrIGF-1 was encapsulated into poly(lactide-co-glycolide) (PLGA) microspheres to produce a sustained-release effect around titanium (Ti) dental implants in the rrIGF-1 MST group. Scanning electron microscopy, confocal laser scanning microscopy, and cumulative-release studies were conducted to verify the release effect of the microspheres as well as rrIGF-1 bioactivity. Five rats from each group were sacrificed at weeks 4 and 8 post surgery, and a histological analysis was performed on the rats from both groups. Compared to the control group, rats that received rrIGF-1 by PLGA microsphere treatment were observed to have a higher bone-implant contact percentage around the Ti implants at week 4 or week 8 post surgery (Pdental implants in type 2 diabetic rats.

  19. Surgical Cooperation during Implantation of a Boston type-I Keratoprosthesis

    Institute of Scientific and Technical Information of China (English)

    Bishan Tian; Sufen Lu; Hairong Zhang; Feipeng Wang; Jiaqi Chen; Jiajie Zhai; Lijin Su

    2014-01-01

    This study was designed to summarize the key points of surgical cooperation involving penetrating corneal transplanta-tion combined with implantation of keratoprosthesis. Preopera-tive preparation and intraoperative procedures were fully im-plemented to ensure cooperation with the physicians,.to ob-serve the the severity of the disease, and to guarantee the success of the surgery.

  20. [Influence of attachment type on stress distribution of implant-supported removable partial dentures].

    Science.gov (United States)

    Yang, Xue; Rong, Qi-guo; Yang, Ya-dong

    2015-02-18

    To compare influences of different retention attachments on stress among supporting structures. By 3-dimensional laser scanner and reverse engineering computer aided design (CAD) software, a basic partially edentulous digital model with mandibular premolar and molar missing was established. Implant attachment and removable partial dentures (RPD) were added into the basic model to build three kinds of models: RPD only, RPD + implant + Locator attachment, and RPD + implant + Magfit attachment. Vertical and inclined loads were put on artificial teeth unilaterally. By means of 3-dimensional finite element analysis, the stress distribution and displacement of the main supportive structures were compared. A complete 3-dimensional finite element model was established, which contained tooth structure, and periodontal structures. The displacement of the denture was smaller in Locator (9.38 μm vertically, 45.48 μm obliquely) and Magfit models (9.54 μm vertically, 39.45 μm obliquely) compared with non-implant RPD model (95.27 μm vertically, 155.70 μm obliquely). Compared with the two different attachments, cortical bone stress value was higher in Locator model (Locator model 10.850 MPa vertically, 43.760 MPa obliquely; Magfit model 7.100 MPa vertically, 19.260 MPa obliquely).The stress value of abutment periodontal ligamentin Magfit model (0.420 MPa vertically) was lower than that in Locator model (0.520 MPa vertically). The existence of implant could reduce maximum von Mises value of each supportive structure when Kennedy I partially edentulous mandible was restored. Comparing the structure of Magfit and Locator attachment, the contact of Magfit attachment was rigid, while Locator was resilient. Locator attachment could improve stability of the denture dramatically. Locator had stronger effect on defending horizontal movement of the denture.

  1. Weldability of AISI 304 to copper by friction welding

    Energy Technology Data Exchange (ETDEWEB)

    Kirik, Ihsan [Batman Univ. (Turkey); Balalan, Zulkuf [Firat Univ., Elazig (Turkey)

    2013-06-01

    Friction welding is a solid-state welding method, which can join different materials smoothly and is excessively used in manufacturing industry. Friction welding method is commonly used in welding applications of especially cylindrical components, pipes and materials with different properties, for which other welding methods remain incapable. AISI 304 stainless steel and a copper alloy of 99.6 % purity were used in this study. This couple was welded in the friction welding machine. After the welding process, samples were analyzed macroscopically and microscopically, and their microhardness was measured. Tensile test was used to determine the bond strength of materials that were joined using the friction welding method. At the end of the study, it was observed that AISI 304 stainless steel and copper could be welded smoothly using the friction welding method and the bond strength is close to the tensile strength of copper. (orig.)

  2. Laser Welding Of Thin Sheet Of AISI 301 Stainless Steel

    Science.gov (United States)

    Vilar, R.; Miranda, R. M.

    1989-01-01

    Preliminary results of an investigation on laser welding of AISI 301 stainless steel thin sheet are presented. Welds were made with a CO2 continuous wave laser, varying power density and welding speed. The welds were studied by optical and electron scanning microscopy, X-ray diffraction and hardness tests. Experimental results show that under appropriate conditions, sound welds are obtained, with a negligeable heat affected zoneanda fine microstructure in the fusion zone. The fusion zone shows a cellular - dendritic microstructure, with austenite and ferrite as the major constituents. Ferrite, whose content is 5 to 7%, is predominantly intradendritic with both vermicular and acicular morphologies. However some interdendritic ferrite may also be present. The characteristics of the structure suggest that the solidification mode of AISI 301 stainless steel is essentially ferritic.

  3. Tribological and corrosion behaviors of carburized AISI 4340 steel

    Science.gov (United States)

    Thong-on, Atcharawadi; Boonruang, Chatdanai

    2016-01-01

    AISI 4340 steel is widely used in automotive and aircraft industries as gear components. In such applications, surface hardening processes such as carburizing are required in order to improve the life time of the components. There are many studies showing the tribological behavior of the carburized steel, but the corrosion behavior has not yet been clarified. This paper reports on both tribological and corrosion behaviors of the carburized AISI 4340 steel. Factor associated with carburizing, such as the quantities of deposited carbon, dissolved carbon, and formed Cr23C6 and Fe3C, affect the tribological and corrosion behaviors of the steel by improving hardness, friction, lubrication, and wear resistance; but corrosion resistance is reduced. The dissolved carbon affects the formation of the oxide layer of the carburized steel, by obstructing the continuous oxide layer formation and by decreasing the chromium content of the steel, leading to the decrease in the corrosion resistance of the steel.

  4. Magnetic Barkhausen emission in lightly deformed AISI 1070 steel

    Energy Technology Data Exchange (ETDEWEB)

    Capo Sanchez, J., E-mail: jcapo@cnt.uo.edu.cu [Departamento de Fisica, Facultad de Ciencias Naturales, Universidad de Oriente, Av. Patricio Lumumba s/n, 90500 Santiago de Cuba (Cuba); Campos, M.F. de [EEIMVR-Universidade Federal Fluminense, Av. dos Trabalhadores 420, Vila Santa Cecilia, 27255-125 Volta Redonda, RJ (Brazil); Padovese, L.R. [Departamento de Engenharia Mecanica, Escola Politecnica, Universidade de Sao Paulo, Av. Prof. Mello Moraes, 2231, 05508-900 Sao Paulo (Brazil)

    2012-01-15

    The Magnetic Barkhausen Noise (MBN) technique can evaluate both micro- and macro-residual stresses, and provides indication about the relevance of contribution of these different stress components. MBN measurements were performed in AISI 1070 steel sheet samples, where different strains were applied. The Barkhausen emission is also analyzed when two different sheets, deformed and non-deformed, are evaluated together. This study is useful to understand the effect of a deformed region near the surface on MBN. The low permeability of the deformed region affects MBN, and if the deformed region is below the surface the magnetic Barkhausen signal increases. - Highlights: > Evaluated residual stresses by the magnetic Barkhausen technique. > Indication about the relevance of micro-and macro-stress components. > Magnetic Barkhausen measurements were carried out in AISI 1070 steel sheet samples. > Two different sheets, deformed and non-deformed, are evaluated together. > Magnetic Barkhausen signal increases when deformed region is below the surface.

  5. Laser surface hardening of AISI H13 tool steel

    Institute of Scientific and Technical Information of China (English)

    Jae-Ho LEE; Jeong-Hwan JANG; Byeong-Don JOO; Young-Myung SON; Young-Hoon MOON

    2009-01-01

    An attempt was made to improve the surface hardness and wear properties of AISI H13 tool steel through solid solution hardening and refinement of microstructures using a 200 W fiber laser as a heat generating source. The hardness of laser melted zone was investigated. In order to identify the effect of heat input on the laser melting zone, scanning conditions were controlled. The results show that, the hardness of as-received AISI H13 tool steel is approximately Hv 240, and the hardness after laser surface heat treatment is around Hv 480-510. The hardening depth and width are increased with the increase in the heat input applied. Application of experimental results will be considered in tooling industry.

  6. Cutting Forces Analysis in Additive Manufactured AISI H13 Alloy

    OpenAIRE

    Montevecchi, Filippo; Grossi, Niccolò; Takagi, Hisataka; Scippa, Antonio; Sasahara, Hiroyuki; Campatelli, Gianni

    2016-01-01

    Combining Additive Manufacturing (AM) and traditional machining processes is essential to meet components functional requirements. However significant differences arise in machining AM and wrought parts. Previous works highlighted the increasing of tool wear and worse surface finish. In this paper cutting forces are investigated as an indicator of material machinability. Milling cutting force coefficients are identified using mechanistic approach, comparing AISI-H13 wrought and AM specimen. C...

  7. The aluminizing in powder technology of AISI 304 steel

    Science.gov (United States)

    Băitanu, D. B.; Găluşcă, D. G.; Achiţei, D. C.; Minciună, M. G.; Bakri Abdullah, Mohd Mustafa Al

    2016-06-01

    The paper presents a study about the aluminizing treatments applied to AISI 304 stainless steel, with the purpose to improve the corrosion resistance. The aluminizing is realized in a powder medium, composed by aluminium powder (with 99.95% purity), aluminium oxide Al2O3 and ammonium chloride NH4Cl. The structural characterization was made by scanning electronic microscopy to highlight the structure of layer after aluminizing, at different magnitudes.

  8. Altered spatiotemporal expression of collagen types I, III, IV, and VI in Lpar3-deficient peri-implantation mouse uterus.

    Science.gov (United States)

    Diao, Honglu; Aplin, John D; Xiao, Shuo; Chun, Jerold; Li, Zuguo; Chen, Shiyou; Ye, Xiaoqin

    2011-02-01

    Lpar3 is upregulated in the preimplantation uterus, and deletion of Lpar3 leads to delayed uterine receptivity in mice. Microarray analysis revealed that there was higher expression of Col3a1 and Col6a3 in the Preimplantation Day 3.5 Lpar3(-/-) uterus compared to Day 3.5 wild-type (WT) uterus. Since extracellular matrix (ECM) remodeling is indispensable during embryo implantation, and dynamic spatiotemporal alteration of specific collagen types is part of this process, this study aimed to characterize the expression of four main uterine collagen types: fibril-forming collagen (COL) I and COL III, basement membrane COL IV, and microfibrillar COL VI in the peri-implantation WT and Lpar3(-/-) uterus. An observed delay of COL III and COL VI clearance in the Lpar3(-/-) uterus may be associated with higher preimplantation expression of Col3a1 and Col6a3. There was also delayed clearance of COL I and delayed deposition of COL IV in the decidual zone in the Lpar3(-/-) uterus. These changes were different from the effects of 17beta-estradiol and progesterone on uterine collagen expression in ovariectomized WT uterus, indicating that the altered collagen expression in Lpar3(-/-) uterus is unlikely to be a result of alterations in ovarian hormones. Decreased expression of several genes encoding matrix-degrading metallo- and serine proteinases was observed in the Lpar3(-/-) uterus. These results demonstrate that pathways downstream of LPA3 are involved in the dynamic remodeling of ECM in the peri-implantation uterus.

  9. Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions.

    Science.gov (United States)

    López, Danián Alejandro; Durán, Alicia; Ceré, Silvia Marcela

    2008-05-01

    Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 degrees C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.

  10. Breast Reconstruction with Implants

    Science.gov (United States)

    Breast reconstruction with implants Overview By Mayo Clinic Staff Breast reconstruction is a surgical procedure that restores shape to ... treat or prevent breast cancer. One type of breast reconstruction uses breast implants — silicone devices filled with silicone ...

  11. The angiotensin II type 1 receptor blocker losartan attenuates bioprosthetic valve leaflet calcification in a rabbit intravascular implant model.

    Science.gov (United States)

    Shin, Hong Ju; Kim, Dae-Hyun; Park, Han Ki; Park, Young Hwan

    2016-12-01

    There is evidence that angiotensin II type I receptor blocker (ARB) could reduce structural valve deterioration. However, the anticalcification effect on the bioprosthetic heart valve (BHV) has not been investigated. Thus, we investigated the effects of losartan (an ARB) on calcification of implanted bovine pericardial tissue in a rabbit intravascular implant model. A total of 16 male New Zealand White rabbits (20 weeks old, 2.98-3.34 kg) were used in this study. Commercially available BHV leaflet of bovine pericardium was trimmed to the shape of a 3-mm triangle and implanted to both external jugular veins of the rabbit. The ARB group (n = 8) was given 25 mg/kg of powdered losartan daily until 6 weeks after surgery by direct administration in the buccal pouch of the animals. The control group (n = 8) was given 5 ml of normal saline by the same method. After 6 weeks, quantitative calcium determination, histological evaluation and western blot analysis of interleukin-6 (IL-6), osteopontin and bone morphogenetic protein 2 (BMP-2) were performed to investigate the mechanisms of the anticalcification effect of losartan. No deaths or complications such as infection or haematoma were recorded during the experiment. All animals were euthanized on the planned date. The calcium measurement level in the ARB group (2.28 ± 0.65 mg/g) was significantly lower than that in the control group (3.68 ± 1.00 mg/g) (P = 0.0092). Immunohistochemistry analyses revealed that BMP-2-positive reactions were significantly attenuated in the ARB group. Western blot analysis showed that losartan suppressed the expression of IL-6, osteopontin and BMP-2. Our results indicate that losartan significantly attenuates postimplant degenerative calcification of a bovine pericardial bioprosthesis in a rabbit intravascular implant model. Further studies are required to assess the effects of ARBs on BHV tissue in orthotopic implantations using a large animal model. © The Author 2016. Published by Oxford

  12. Corrosion resistance of multilayer hybrid sol-gel coatings deposited on the AISI 316L austenitic stainless steel

    Science.gov (United States)

    Caballero, Y. T.; Rondón, E. A.; Rueda, L.; Hernández Barrios, C. A.; Coy, A.; Viejo, F.

    2016-02-01

    In the present work multilayer hybrid sol-gel coatings were synthesized on the AISI 316L austenitic stainless steel employed in the fabrication of orthopaedic implants. Hybrid sols were obtained from a mixture of inorganic precursor, TEOS, and organic, GPTMS, using ethanol as solvent, and acetic acid as catalyst. The characterization of the sols was performed using pH measurements, rheological tests and infrared spectroscopy (FTIR) for different ageing times. On the other hand, the coatings were characterized by scanning electron microscopy (SEM), while the corrosion resistance was evaluated using anodic potentiodynamic polarization in SBF solution at 37±2°C. The results confirmed that sol-gel synthesis employing TEOS-GPTMS systems produces uniform and homogeneous coatings, which enhanced the corrosion resistance with regard to the parent alloy. Moreover, corrosion performance was retained after applying more than one layer (multilayer coatings).

  13. Impact of type 2 diabetes on the gene expression of bone-related factors at sites receiving dental implants.

    Science.gov (United States)

    Conte, A; Ghiraldini, B; Casarin, R C; Casati, M Z; Pimentel, S P; Cirano, F R; Duarte, P M; Ribeiro, F V

    2015-10-01

    This study evaluated the influence of type 2 diabetes mellitus (T2DM) on the gene expression of bone-related factors in alveolar bone tissue from sites designated to receive dental implants. Bone biopsies were harvested from sites of planned implants for 19 systemically healthy patients and 35 patients with T2DM (17 with better-controlled T2DM (glycated haemoglobin (HbA1c) levels ≤8%) and 18 with poorly controlled T2DM (HbA1c levels >8%)). The mRNA levels of tumour necrosis factor alpha, transforming growth factor beta, receptor activator of the nuclear factor kappa B ligand (RANKL), osteoprotegerin (OPG), runt-related transcription factor 2, alkaline phosphatase, bone sialoprotein (BSP), type I collagen (COL-I), and osteocalcin were evaluated by quantitative real-time polymerase chain reaction. T2DM up-regulates RANKL levels and the ratio of RANKL/OPG, whereas it down-regulates COL-I and BSP expression (Pdiabetics. Additionally, the patient's glycaemic status appears to modulate bone-related genes in a different manner.

  14. Effect of adhesive geometry on the tensile properties of AISI 1350 steel

    Directory of Open Access Journals (Sweden)

    A. Yasar

    2011-01-01

    Full Text Available It is utilized increasingly to use adhesive bonding in automotive industry to join structural components of metallic materials. The aim of this experimental study is to extend the information available to the automotive design engineer and contribute the better understanding of how the various geometrical shaped of steel parts affect the adhesive bonding. In this study, different types of lap joints, such as butt, step butt, scarf, tubular lap, were used to determine the mechanical strength of SAE/AISI 1350 steel. It has been observed that the cylindrical geometries can be subject to more stress compared to square specimens generally and the geometries with both tensile and shear stress can stand more stress per unit compared with the specimens with only tensile stress.

  15. Breast Implants

    Science.gov (United States)

    ... Medical Procedures Implants and Prosthetics Breast Implants Breast Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Breast implants are medical devices that are implanted under the ...

  16. Atrial fibrillation burden in Myotonic Dystrophy type 1 patients implanted with dual chamber pacemaker: the efficacy of the overdrive atrial algorithm at 2 year follow-up

    OpenAIRE

    Russo, Vincenzo; NIGRO, GERARDO; Rago, Anna; ANTONIO PAPA, ANDREA; PROIETTI, RICCARDO; Della Cioppa, Nadia; CRISTIANO, ANNA; PALLADINO, ALBERTO; Calabrò, Raffaele; Politano, Luisa

    2013-01-01

    The role that atrial pacing therapy plays on the atrial fibrillation (AF) burden is still unclear. Aim of the study was to evaluate the effect of the atrial preference pacing algorithm on AF burden in patients affected by Myotonic Dystrophy type 1 (DM1) followed for a long follow up period. Sixty DM1 patients were -implanted with a dual chamber pacemaker (PM) for first degree or symptomatic type 1/type 2 second degree atrio-ventricular blocks- were followed for 2-years after implantation, by ...

  17. Influence of gas pressure and substrate temperature on PIII nitrocarburizing process of AISI 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Rahman, A.M. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt) and Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany)]. E-mail: ahmedphys96@hotmail.com; El-Hossary, F.M. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt); Negm, N.Z. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt); Prokert, F. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany); Richter, E. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany); Moeller, W. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany)

    2004-12-01

    Plasma immersion ion implantation (PIII) has been used to modify the surface properties of 304 austenitic stainless steel (AISI). The influence of working gas pressure, 0.2-1.0 Pa, and substrate temperature, 300-500 deg. C, on the microstructure, treating rate, nitrogen/carbon concentration depth profile, and surface microhardness was investigated. A gas composition of 25% C{sub 2}H{sub 2}, 75% N{sub 2}, r.f. plasma power input of 350 W, and a negatively biased potential of 30 kV were fixed during the experiment. The experimental results show that the substrate temperature and the diffusion process of nitrogen and carbon depend on the gas pressure inside the plasma chamber. The thickness of the modified layer has been found to be more than 30 {mu}m for samples were treated in the plasma for 60 min. The results show also that the values of diffusion coefficient and surface microhardness of the treated samples are high to be 3.4 x 10{sup -1} {mu}m{sup 2}/s and 1880 kg/mm{sup 2}, respectively.

  18. Influence of gas pressure and substrate temperature on PIII nitrocarburizing process of AISI 304 stainless steel

    Science.gov (United States)

    Abd El-Rahman, A. M.; El-Hossary, F. M.; Negm, N. Z.; Prokert, F.; Richter, E.; Möller, W.

    2004-12-01

    Plasma immersion ion implantation (PIII) has been used to modify the surface properties of 304 austenitic stainless steel (AISI). The influence of working gas pressure, 0.2-1.0 Pa, and substrate temperature, 300-500 °C, on the microstructure, treating rate, nitrogen/carbon concentration depth profile, and surface microhardness was investigated. A gas composition of 25% C2H2, 75% N2, r.f. plasma power input of 350 W, and a negatively biased potential of 30 kV were fixed during the experiment. The experimental results show that the substrate temperature and the diffusion process of nitrogen and carbon depend on the gas pressure inside the plasma chamber. The thickness of the modified layer has been found to be more than 30 μm for samples were treated in the plasma for 60 min. The results show also that the values of diffusion coefficient and surface microhardness of the treated samples are high to be 3.4 × 10-1 μm2/s and 1880 kg/mm2, respectively.

  19. Performance Assessment of Suture Type in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.; Boyd, James W.

    2009-02-27

    The objective of this study was to determine the best overall suture material to close incisions from the surgical implantation of Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic microtransmitters in subyearling Chinook salmon Oncorhynchus tshawytscha. The effects of seven suture materials, four surgeons, and two water temperatures on suture retention, incision openness, tag retention, tissue inflammation, and tissue ulceration were quantified. The laboratory study, conducted by researchers at the Pacific Northwest National Laboratory, supports a larger effort under way for the U.S. Army Corps of Engineers, Portland District, aimed at determining the suitability of acoustic telemetry for estimating short- and longer-term (30-60 days) juvenile-salmonid survival at Columbia and Snake River dams and through the lower Columbia River.

  20. Influence of Thread Pitch, Helix Angle, and Compactness on Micromotion of Immediately Loaded Implants in Three Types of Bone Quality: A Three-Dimensional Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Pan Ma

    2014-01-01

    Full Text Available This study investigated the influence of thread pitch, helix angle, and compactness on micromotion in immediately loaded implants in bone of varying density (D2, D3, and D4. Five models of the three-dimensional finite element (0.8 mm pitch, 1.6 mm pitch, 2.4 mm pitch, double-threaded, and triple-threaded implants in three types of bone were created using Pro/E, Hypermesh, and ABAQUS software. The study had three groups: Group 1, different pitches (Pitch Group; Group 2, same compactness but different helix angles (Angle Group; and Group 3, same helix angle but different compactness (Compact Group. Implant micromotion was assessed as the comprehensive relative displacement. We found that vertical relative displacement was affected by thread pitch, helix angle, and compactness. Under vertical loading, displacement was positively correlated with thread pitch and helix angle but negatively with compactness. Under horizontal loading in D2, the influence of pitch, helix angle, and compactness on implant stability was limited; however, in D3 and D4, the influence of pitch, helix angle, and compactness on implant stability is increased. The additional evidence was provided that trabecular bone density has less effect on implant micromotion than cortical bone thickness. Bone type amplifies the influence of thread pattern on displacement.

  1. Human fetal islet transplantation in type 1 diabetic patients: comparison of metabolic effects between single and multiple implantation regimens.

    Science.gov (United States)

    Djordjevic, P B; Lalic, N M; Jotic, A; Paunovic, I; Lalic, K; Raketic, N; Nikolic, D; Zamaklar, M; Rajkovic, N; Lukic, L; Dimitrijevic-Sreckovic, V; Dragasevic, M; Nikolic, D; Markovic, I

    2004-11-01

    Previous studies suggest that multiple transplantations might be equally efficient to a single regimen for human adult islets. The aim of this study was to compare metabolic parameters after each of the two regimens of human fetal islet (HFI) transplantation in type 1 diabetics. In group A (single transplant, n = 9), 180 +/- 20 x 1000 HFI equivalents (IEQs) were implanted by a single IM injection; in group B (multiple transplants, n = 8) islets were implanted as three consecutive injections (60 +/- 10 x 1000 IEQs) at 7-day intervals. We analyzed the metabolic parameters on days -1, 30, 60, 90, 120, 150, and 180 after the procedure. Among the metabolic parameters, we evaluated insulin secretion capacity-ISC (C peptide, RIA), metabolic control (HbA1c, chromatography), and insulin daily dose IDD. We found that C peptide levels increased, peaking on day 90 (A: 0.38 +/- 0.15; B: 0.34 +/- 0.19 nmol/L, P = NS) and then rapidly decreasing without differences, the HbA1c levels and IDD decreased in the same manner without differences between the groups. Our results demonstrate that multiple and single islet transplant regimens are equally efficient to temporarily restore a significant ISC with improvement of metabolic and clinical parameters. The results imply that the two regimens have an equal clinical value.

  2. Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study.

    Science.gov (United States)

    Gilde, Alex K; Jones, Clifford B; Sietsema, Debra L; Hoffmann, Martin F

    2014-07-04

    The purpose of this study was to evaluate surgical healing rates, implant failure, implant removal, and the need for surgical revision with regards to plate type in midshaft clavicle fractures fixed with 2.7-mm anteroinferior plates utilizing modern plating techniques. This retrospective exploratory cohort review took place at a level I teaching trauma center and a single large private practice office. A total of 155 skeletally mature individuals with 156 midshaft clavicle fractures between March 2002 and March 2012 were included in the final results. Fractures were identified by mechanism of injury and classified based on OTA/AO criteria. All fractures were fixed with 2.7-mm anteroinferior plates. Primary outcome measurements included implant failure, malunion, nonunion, and implant removal. Secondary outcome measurements included pain with the visual analog scale and range of motion. Statistically significant testing was set at 0.05, and testing was performed using chi-square, Fisher's exact, Mann-Whitney U, and Kruskall-Wallis. Implant failure occurred more often in reconstruction plates as compared to dynamic compression plates (p = 0.029). Malunions and nonunions occurred more often in fractures fixed with reconstruction plates as compared to dynamic compression plates, but it was not statistically significant. Implant removal attributed to irritation or implant prominence was observed in 14 patients. Statistically significant levels of pain were seen in patients requiring implant removal (p = 0.001) but were not associated with the plate type. Anteroinferior clavicular fracture fixation with 2.7-mm dynamic compression plates results in excellent healing rates with low removal rates in accordance with the published literature. Given higher rates of failure, 2.7-mm reconstruction plates should be discouraged in comparison to stiffer and more reliable 2.7-mm dynamic compression plates.

  3. Glow Discharge Plasma Nitriding of AISI 304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    A.QAYYUM; M.A.NAVEED; S.ZEB; G.MURTAZA; M.ZAKAULLAH

    2007-01-01

    Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis.The treated samples were analysed by X-ray diffraction(XRD)to explore the changes induced in the crystallographic structure.The XRD pattern confirmed the formation of an expanded austenite phase(γN)owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice.A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth(μm).The results showed clear evidence of surface changes with substantial increase in surface hardness.

  4. A study of cumulative fatigue damage in AISI 4130 steel

    Science.gov (United States)

    Jeelani, S.; Musial, M.

    1986-01-01

    Experimental data were obtained using AISI 4130 steel under stress ratios of -1 and 0. A study of cumulative fatigue damage using Miner's and Kramer's equations for stress ratios of -1 and 0 for low-high, low-high-mixed, high-low, and high-low-mixed stress sequences has revealed that there is a close agreement between the theoretical and experimental values of fatigue damage and fatigue life. Kramer's equation predicts less conservative and more realistic cumulative fatigue damage than the popularly used Miner's rule does.

  5. Effect of the purging gas on properties of Ti stabilized AISI 321 stainless steel TIG welds

    Energy Technology Data Exchange (ETDEWEB)

    Taban, Emel; Kaluc, Erdinc; Aykan, T. Serkan [Kocaeli Univ. (Turkey). Dept. of Mechanical Engineering

    2014-07-01

    Gas purging is necessary to provide a high quality of stainless steel pipe welding in order to prevent oxidation of the weld zone inside the pipe. AISI 321 stabilized austenitic stainless steel pipes commonly preferred in refinery applications have been welded by the TIG welding process both with and without the use of purging gas. As purging gases, Ar, N{sub 2}, Ar + N{sub 2} and N{sub 2} + 10% H{sub 2} were used, respectively. The aim of this investigation is to detect the effect of purging gas on the weld joint properties such as microstructure, corrosion, strength and impact toughness. Macro sections and microstructures of the welds were investigated. Chemical composition analysis to obtain the nitrogen, oxygen and hydrogen content of the weld root was done by Leco analysis. Ferrite content of the beads including root and cap passes were measured by a ferritscope. Vickers hardness (HV10) values were obtained. Intergranular and pitting corrosion tests were applied to determine the corrosion resistance of all welds. Type of the purging gas affected pitting corrosion properties as well as the ferrite content and nitrogen, oxygen and hydrogen contents at the roots of the welds. Any hot cracking problems are not predicted as the weld still solidifies with ferrite in the primary phase as confirmed by microstructural and ferrite content analysis. Mechanical testing showed no significant change according to the purge gas. AISI 321 steel and 347 consumable compositions would permit use of nitrogen rich gases for root shielding without a risk of hot cracking.

  6. Aluminum coating by fluidized bed chemical vapor deposition on austenitic stainless steels AISI 304 and AISI 316

    Directory of Open Access Journals (Sweden)

    Jose Luddey Marulanda-Arevalo

    2015-01-01

    Full Text Available Los revestimientos de aluminio f ueron depositados sobre aceros inoxidables AISI 304 y AISI 316 en el rango de temperatura de 5 60 a 600 °C por deposición química de vapor en lecho fluidizado(CVD – FBR. Se utilizó un lecho que consistía en 10 % de aluminio en polvo y 90 % de lecho inerte (alúmina, el cual fue fluidizado con Ar y como ga ses activadores se utilizó una mezcla de ácido clorhídrico con hidrógeno (HCl/H 2 . En el recubrimiento si n tratamiento térmico están las siguiente s especies: Al 13 Fe 4 , Fe 2 Al 5 , FeAl 2 y Al 5 FeNi, las cuales están presentes para ambos aceros. Además, el tratamiento térmico provoca la difusa de alu minio hacia el sustrato y la difusa de hierro del sustrato haci a la superficie del recubrimiento, haciendo la trans formación de los compuestos ant eriores a FeAl, Fe 2 Al 5 , FeAl 2 , Al 0.99 Fe 0.99 Ni 0.02 , AlNi y el Fe 2 AlCr. Se realizó la simulación termodinámica con el s oftware Thermo Calc para obt ener información de la posible composición y la cantidad de mat erial depositado, para condiciones seleccionadas. Las muestras recubi ertas y sin recubrir, se expus ieron a 750 ºC en una atmósfera d onde el vapor agua se transporta a las muestras usando un flujo de N 2 de 40 ml/min, más 100 % vapor de agua (H 2 O. Los dos sustratos sin revestir se comportaron de manera diferente, ya que el acero AISI 304 soportó bien el a taque y ganó poco peso (0.49 mg/cm 2 , en comparación con el acero AISI 316 que perdió mucho peso (25.4 mg/cm 2 . Los aceros recubiertos ganaron poco de peso durante las mil horas de exposición (0.26 mg/cm 2 y soportaron muy bien el ataque corrosivo en c omparación con sustratos sin r ecubrimiento.

  7. N-type doping of Ge by As implantation and excimer laser annealing

    Energy Technology Data Exchange (ETDEWEB)

    Milazzo, R.; Napolitani, E., E-mail: enrico.napolitani@unipd.it; De Salvador, D.; Mastromatteo, M.; Carnera, A. [CNR-IMM MATIS and Dipartimento di Fisica Astronomia, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); Impellizzeri, G.; Boninelli, S.; Priolo, F.; Privitera, V. [CNR-IMM MATIS and Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Fisicaro, G.; Italia, M.; La Magna, A. [CNR-IMM, Z.I. VIII Strada 5, 95121 Catania (Italy); Cuscunà, M.; Fortunato, G. [CNR-IMM, Via del Fosso del Cavaliere 100, 00133 Roma (Italy)

    2014-02-07

    The diffusion and activation of arsenic implanted into germanium at 40 keV with maximum concentrations below and above the solid solubility (8 × 10{sup 19} cm{sup −3}) have been studied, both experimentally and theoretically, after excimer laser annealing (λ = 308 nm) in the melting regime with different laser energy densities and single or multiple pulses. Arsenic is observed to diffuse similarly for different fluences with no out-diffusion and no formation of pile-up at the maximum melt depth. The diffusion profiles have been satisfactorily simulated by assuming two diffusivity states of As in the molten Ge and a non-equilibrium segregation at the maximum melt depth. The electrical activation is partial and decreases with increasing the chemical concentration with a saturation of the active concentration at 1 × 10{sup 20} cm{sup −3}, which represents a new record for the As-doped Ge system.

  8. Analysis of the elements sputtered during the lanthanum implantation in stainless steels

    Science.gov (United States)

    Ager, F. J.; Respaldiza, M. A.; Paúl, A.; Odriozola, J. A.; Lobato, J. M.; da Silva, M. F.; Redondo, L. M.; Soares, J. C.

    1998-04-01

    The evidence of the modification of the surface structure of the AISI-304 stainless steel during the implantation of lanthanum makes the analysis of the sputtered elements very interesting. Those sputtered elements are deposited on a carbon sheet placed in front of the steel being implanted, and studied by means of RBS and PIXE, together with the implanted specimens. Besides, the protective effect of the implanted ions during the high temperature oxidation is also studied by those techniques together with XRD and thermogravimetric methods.

  9. Analysis of the elements sputtered during the lanthanum implantation in stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Ager, F.J.; Respaldiza, M.A. [Sevilla Univ. (Spain). Dept. de FAMN; Paul, A.; Odriozola, J.A.; Lobato, J.M. [ICMSE, Universidad de Sevilla-CSIC, P.O. Pox 874, 41071 Sevilla (Spain); Silva, M.F. da; Redondo, L.M. [ITN, E.N. 10, 2685 Sacavem (Portugal); Soares, J.C. [CFNUL, Av. Prof. Gama Pinto 2, 1699 Lisboa Codex (Portugal)

    1998-04-01

    The evidence of the modification of the surface structure of the AISI-304 stainless steel during the implantation of lanthanum makes the analysis of the sputtered elements very interesting. Those sputtered elements are deposited on a carbon sheet placed in front of the steel being implanted, and studied by means of RBS and PIXE, together with the implanted specimens. Besides, the protective effect of the implanted ions during the high temperature oxidation is also studied by those techniques together with XRD and thermogravimetric methods. (orig.) 7 refs.

  10. Formation of slab waveguides in eulytine type BGO and CaF{sub 2} crystals by implantation of MeV nitrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Banyasz, I., E-mail: bakonyjako@yahoo.es [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Berneschi, S. [Centro Studi e Ricerche ' Enrico Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); MDF-Lab, ' ' Nello Carrara' ' Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Khanh, N.Q.; Lohner, T. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Lengyel, K. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Fried, M. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Peter, A. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Petrik, P.; Zolnai, Z. [Research Institute for Technical Physics and Materials Science of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Watterich, A. [Department of Crystal Physics, Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, P.O. Box 49, H-1525 Budapest (Hungary); Nunzi-Conti, G.; Pelli, S.; Righini, G.C. [MDF-Lab, ' ' Nello Carrara' ' Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy)

    2012-09-01

    Ion implantation, compared with other waveguide fabrication methods, has some unique advantages. It has proved to be a universal technique for producing waveguides in most optical materials. The authors of the present article reported fabrication of channel and slab waveguides in an Erbium-doped tungsten tellurite glass by implantation of MeV energy N{sup +} ions. The present article reports successful adaptation of the same technique to the fabrication of slab waveguides in eulytine type bismuth germanate (BGO) and CaF{sub 2} crystals. This is the first report on successful waveguide fabrication in these materials using 3.5 MeV N{sup +} ions at implanted fluences between 5 Multiplication-Sign 10{sup 15} and 4 Multiplication-Sign 10{sup 16} ions/cm{sup 2}. Spectroscopic ellipsometric measurements revealed the existence of guiding structures in both materials. M-line spectroscopic measurements indicated guiding effect in the as-implanted BGO up to 1550 nm and up to 980 nm in the as-implanted CaF{sub 2}. Ion implantation induced the appearance of three peaks in the UV/Vis absorption spectrum of CaF{sub 2}, that can be attributed to colour centres.

  11. Resistance Spot Weldability of Dissimilar Materials: BH180-AISI304L Steels and BH180-IFT123 Steels

    Institute of Scientific and Technical Information of China (English)

    Fatih Hayat

    2011-01-01

    In this study, resistance spot weldability of 180 grade bake hardening steel (BH180), 7123 grade interstitial free steel (IF7123) and 304 grade austenitic stainless steel (AISI304L) with each other was investigated. In the joining process, electrode pressure and weld current were kept constant and six different weld time were chosen. Microstructure, microhardness, tensile-shear properties and fracture types of resistance spot welded joints were examined. In order to characterize the metallurgical structure of the welded joint, the microstructural profile was developed, and the relationship between mechanical properties and microstructure was determined. The change of weld time, nugget diameter, the HAZ (heat affected zone) width and the electrode immersion depth were also investigated. Welded joints were examined by SEM (scanning electron microscopy) images of fracture surface. As a result of the experiment, it was determined that with increasing weld time, tensile shear load bearing capacity (TLBC) increased with weld time up to 25 cycle and two types of tearing occurred. It was also determined that while the failure occurred from IF side at the BHIS0+IF7123 joint, it occurred from the BH180 side at the BHIS0+AISI304L joint.

  12. PERFORMANCE STUDY ON AISI316 AND AISI410 USING DIFFERENT LAYERED COATED CUTTING TOOLS IN CNC TURNING

    Directory of Open Access Journals (Sweden)

    K. RAJA

    2015-01-01

    Full Text Available Stainless steel (SS is used for many commercial and industrial applications owing to its high resistance to corrosion. It is too hard to machine due to its high strength and high work hardening property. A surface property such as surface roughness (SR is critical to the function-ability of machined components. SS is generally regarded as more difficult to machine material and poor SR is obtained during machining. In this paper an attempt has been made to investigate the SR produced by CNC turning on austenitic stainless steel (AISI316 and martensitic stainless steel (AISI410 by different cases of coated cutting tool used at dry conditions. Multilayered coated with TiCN/Al2O3, multilayered coated with Ti(C, N, B and single layered coated with TiAlN coated cutting tools are used. Experiments were carried out by using Taguchi’s L27 orthogonal array. The effect of cutting parameters on SR is evaluated and optimum cutting conditions for minimizing the SR are determined. Analysis of variance (ANOVA is used for identifying the significant parameters affecting the responses. Confirmation experiments are conducted to validate the results obtained from optimization.

  13. Antibacterial Property of Martensitic Stainless Steel Generated by Cu Ion Implantation

    Institute of Scientific and Technical Information of China (English)

    XU Bo-fan; NI Hong-wei; DAN Zhi-gang; XIONG Juan; XIONG Ping-yuan

    2004-01-01

    Copper ions were implanted into a AISI420 martensitic stainless steel (SS) by metal vapor vacuum arc (MEVVA) with a dose range 0.2 ×1017 ~5.0×1017 cm-2 at the energy of 100keV. The Cu-implanted stainless steel was treated by a special antibacterial treatment subsequently. The phase compositions in the implanted layer were studied by glancing X-ray diffraction (GXRD) and changes of bacterial appearance on the surface of Cu un-implanted SS and Cu-implanted SS with antibacterial treatment SS were observed by bio-TEM (transmission electron microscopy) separately. The results showed that a suitable amount of Cu-rich phase was dispersed in the implanted layer of Cu-implanted SS that was treated by special antibacterial treatment. So the Cu-implanted martensitic stainless steel with antibacterial treatment reveals excellent antibacterial property against both E. coli and S. aureus.

  14. Antibacterial Property of Martensitic Stainless Steel Generated by Cu Ion Implantation

    Institute of Scientific and Technical Information of China (English)

    XUBo-fan; NIHong-wei; DANZhi-gang; XIONGJuan; XIONGPing-yuan

    2004-01-01

    Copper ions were implanted into a AISI420 martensitic stainless steel (SS) by metal vapor vacuum arc (MEVVA) with a dose range 0.2×1017-5.0×1017cm-2 at the energy of 100keV. The Cu-implanted stainless steel was treated by a special antibacterial treatment subsequently. The phase compositions in the implanted layer were studied by glancing X-ray diffraction (GXRD) and changes of bacterial appearance on the surface of Cu un-implanted SS and Cu-implanted SS with antibacterial treatment SS were observed by bio-TEM (transmission electron microscopy) separately. The results showed that a suitable amount of Cu-rich phase was dispersed in the implanted layer of Cu-implanted SS that was treated by special antibacterial treatment. So the Cu-implanted martensitic stainless steel with antibacterial treatment reveals excellent antibacterial property against both E. coli and S. aureus.

  15. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    Energy Technology Data Exchange (ETDEWEB)

    Deligianni, X. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology; Bieri, O. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Elke, R. [Orthomerian, Basel (Switzerland); Wischer, T.; Egelhof, T. [Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology

    2015-12-15

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm{sup 3} ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  16. The distressed (Type D) personality in both patients and partners enhances the risk of emotional distress in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    van den Broek, Krista C; Versteeg, Henneke; Erdman, Ruud A M

    2011-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences emotional distress. This may be related to partner factors. We examined the impact of the personality of the partner (i.e., the distressed (Type D) personality) in combination with that of the patient on anxiety...

  17. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation

    DEFF Research Database (Denmark)

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S.

    2013-01-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD)....

  18. In vitro response of human peripheral blood mononuclear cells to AISI 316L austenitic stainless steel subjected to nitriding and collagen coating treatments.

    Science.gov (United States)

    Stio, Maria; Martinesi, Maria; Treves, Cristina; Borgioli, Francesca

    2015-02-01

    Surface modification treatments can be used to improve the biocompatibility of austenitic stainless steels. In the present research two different modifications of AISI 316L stainless steel were considered, low temperature nitriding and collagen-I coating, applied as single treatment or in conjunction. Low temperature nitriding produced modified surface layers consisting mainly of S phase, which enhanced corrosion resistance in PBS solution. Biocompatibility was assessed using human peripheral blood mononuclear cells (PBMC) in culture. Proliferation, lactate dehydrogenase (LDH) levels, release of cytokines (TNF-α, IL-1β, IL-12, IL-10), secretion of metalloproteinase (MMP)-9 and its inhibitor TIMP-1, and the gelatinolytic activity of MMP-9 were determined. While the 48-h incubation of PBMC with all the sample types did not negatively influence cell proliferation, LDH and MMP-9 levels, suggesting therefore a good biocompatibility, the release of the pro-inflammatory cytokines was always remarkable when compared to that of control cells. However, in the presence of the nitrided and collagen coated samples, the release of the pro-inflammatory cytokine IL-1β decreased, while that of the anti-inflammatory cytokine IL-10 increased, in comparison with the untreated AISI 316L samples. Our results suggest that some biological parameters were ameliorated by these surface treatments of AISI 316L.

  19. Plasma nitriding of AISI 304L and AISI 316L stainless steels: effect of time in the formation of S phase and the chromium nitrides; Nitretacao a plasma dos acos inoxidaveis AISI 304L e AISI 316L: efeito do tempo na formacao da fase S e dos nitretos de cromo

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.A. de; Barbosa, G.C.; Pinto, F.A.M.; Gontijo, L.C. [Instituto Federal de Educacao, Ciencia e Tecnologia do Espirito Santo - IFES, Vitoria, ES (Brazil); Canal, G.P.; Cunha, A.G., E-mail: disouzam@yahoo.com.br [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil). Dept. de Fisica

    2009-07-01

    Plasma nitriding can improve hardness and wear resistance of austenitic stainless steels without losses in corrosion resistance. This fact relies on a nitrided layer constituted only by S phase, without chromium nitrides precipitation. In this work, the effect of nitriding time on phases formed on nitrided layer was investigated in two austenitic stainless steels: AISI 304L e AISI 316L. The samples were nitrided at 420 deg C, using a mixture of 60 % N{sub 2} and 40% H{sub 2}, during 5, 7 and 9 hours. It was noted that chromium nitrides were formed on samples of AISI 304L, nitrided for 7 e 9 hours, while all nitrided samples of AISI 316L showed only formation of S phase. The nitrided layers were characterized using optical microscope and x-ray diffraction. (author)

  20. Depth dependent modification of optical constants arising from H+ implantation in n-type 4H-SiC measured using coherent acoustic phonons

    Directory of Open Access Journals (Sweden)

    Andrey Baydin

    2016-06-01

    Full Text Available Silicon carbide (SiC is a promising material for new generation electronics including high power/high temperature devices and advanced optical applications such as room temperature spintronics and quantum computing. Both types of applications require the control of defects particularly those created by ion bombardment. In this work, modification of optical constants of 4H-SiC due to hydrogen implantation at 180 keV and at fluences ranging from 1014 to 1016 cm−2 is reported. The depth dependence of the modified optical constants was extracted from coherent acoustic phonon spectra. Implanted spectra show a strong dependence of the 4H-SiC complex refractive index depth profile on H+ fluence. These studies provide basic insight into the dependence of optical properties of 4H silicon carbide on defect densities created by ion implantation, which is of relevance to the fabrication of SiC-based photonic and optoelectronic devices.

  1. Investigation of Machinability Characteristics of AISI 316Ti Stainless Steel

    Directory of Open Access Journals (Sweden)

    Yunus Kayır

    2012-01-01

    Full Text Available In this study, many experiments of machinability were carried out on universal turning lathe. The cutting forces that occur during machining of workpieces were measured. A standard dynamometer was used to measure cutting forces. The Dynamometer were assembled on the lathe efficiently. An apart were designed and machined to assembly the dynamometer. Moreover, AISI 316Ti stainless steel parts were turned by carbide cutting tools coated with TiAlN components. Effects of cutting tools with different radius on cutting forces and surface roughness were investigated by using different cutting parameters. Moreover, machined parts' surface roughness was controlled. The experimental results showed that cutting forces increased with the increasing federate, but the surface roughness decreased with increasing the radius of cutting edge.

  2. The Study of Plasma Nitriding of AISI304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    WANG Liang; JI Shi-jun; GAO Yu-zhou; SUN Jun-cai

    2004-01-01

    This paper presents results on the plasma nitriding of AISI 304 stainless steel at different temperatures in NH 3 gas. The working pressure was 100~200 Pa and the discharge voltage was 700~800V. The phase of nitrided layer formed on the surface was confirmed by X-ray diffraction. The hardness of the samples was measured by using a Vickers microhardness tester with the load of 50g. After nitriding at about 400 ℃ for two hours a nitrided layer consisting of single γN phase with thickness of 5μm was obtained. Microhardness measurements showed significant increase in the hardness from 240 HV (for untreated samples) up to 950 HV (for nitrided samples at temperature of 420℃). The phase composition, the thickness, the microstructure and the surface topography of the nitrided layer as well as its properties depend essentially on the process parameters.

  3. Fretting of AISI 9310 and selected fretting resistant surface treatments

    Science.gov (United States)

    Bill, R. C.

    1977-01-01

    Fretting wear experiments were conducted with uncoated AISI 9310 mating surfaces, and with combinations incorporating a selected coating to one of the mating surfaces. Wear measurements and SEM observations indicated that surface fatigue, as made evident by spallation and surface crack formation, is an important mechanism in promoting fretting wear to uncoated 9310. Increasing humidity resulted in accelerated fretting, and a very noticeable difference in nature of the fretting debris. Of the coatings evaluated, aluminum bronze with a polyester additive was most effective at reducing wear and minimizing fretting damage to the mating uncoated surface, by means of a selflubricating film that developed on the fretting surfaces. Chromium plate performed as an effective protective coating, itself resisting fretting and not accelerating damage to the uncoated surface.

  4. Experimental survey on the behaviour of AISI 304 steel sheets subjected to perforation

    OpenAIRE

    2010-01-01

    This paper presents and analyzes the behaviour of AISI 304 steel sheets subjected to perforation under a wide range of impact velocities. The relevance of this steel resides in the potential transformation of austenite into martensite during mechanical loading. This process leads to an increase in strength and ductility of the material. It makes the AISI 304 attractive for many engineering applications, especially for building structural elements responsible for absorbing energy under fast lo...

  5. Texture evolution in thin-sheets on AISI 301 metastable stainless steel under dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.Y. [Posco Steels, Pohan, South Korea (Korea, Republic of); Kozaczek, K. [Oak Ridge National Lab., TN (United States); Kulkarni, S.M. [TRW Vehicle Safety Systems, Mesa, AZ (United States); Bastias, P.C.; Hahn, G.T. [Vanderbilt Univ., Nashville, TN (United States)

    1995-05-08

    The evolution of texture in thin sheets of metastable austenitic stainless steel AISI 301 is affected by external conditions such as loading rate and temperature, by inhomogeneous deformation phenomena such as twinning and shear band formation, and by the concurent strain induced phase transformation of the retained austenitc ({gamma}) into martensite ({alpha}). The present paper describes texture measurements on different gauges of AISI 301 prior and after uniaxial stretching under different conditions.

  6. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  7. Comportamiento termomecánico de aceros AISI 304

    Directory of Open Access Journals (Sweden)

    El Wahabi, M.

    2001-04-01

    Full Text Available The hot deformation behaviour of three AISI 304 (H, L and HP austenitic stainless steel with different carbon contents has been studied. An analysis of the parameters describing their hot flow curves was carried out. No heavy effect of the carbon content was found on most of the latter parameters. However, the work hardening and dynamic recovery behaviour showed clear differences depending on the given alloy, especially at high temperatures and low strain rates where the high carbon steel displayed larger work hardening and dynamic recovery rates than the other steels. The high purity steel (interstitial free displayed the lower stress levels as its hardening rate was slower than in the other two steels.

    Se llevó a cabo un estudio del comportamiento termomecánico de tres aceros inoxidables austeníticos tipo AISI 304 (H, L y HP con diferentes contenido en carbono, mediante la determinación de los parámetros que describen las etapas de deformación en caliente. No se notó un fuerte efecto del carbono en dichos parámetros, excepto en los que describen los procesos de endurecimiento y de restauración dinámica que muestran una cierta dependencia con la composición química, especialmente a bajos valores del parámetro de Zener-Hollomon, donde el acero de alto carbono (304H endurece y restaura más rápido que el de bajo carbono (304L, alcanzándose valores de tensión de pico similares en ambos casos. El material de alta pureza (libre de intersticiales toma valores de tensión de pico más bajos que los otros aceros, endureciendo más lentamente y con una velocidad de restauración similar a la del 304H.

  8. Effect of V Notch Shape on Fatigue Life in Steel Beam Made of AISI 1037

    Directory of Open Access Journals (Sweden)

    Qasim Bader

    2014-04-01

    Full Text Available The present work encompasses effect of V notch shape with various geometries and dimensions on fatigue life behavior in steel beam made of Medium Carbon Steel AISI 1037 which has a wide application in industry. Fatigue life of notched specimens is calculated using the fatigue life obtained from the experiments for smooth specimens (reference and by use Numerical method (FEA.The fatigue experiments were carried out at room temperature, applying a fully reversed cyclic load with the frequency of (50Hz and mean stress equal to zero (R= -1, on a cantilever rotating-bending fatigue testing machine. The stress ratio was kept constant throughout the experiment. Different instruments have been used in this investigation like Chemical composition analyzer type (Spectromax ,Tensile universal testing machine type (WDW-100E ,Hardness tester type (HSV- 1000 , Fatigue testing machine model Gunt WP 140, Optical Light Microscope (OLM and Scanning Electron Microscope (SEM were employed to examine the fracture features . The results show that there is acceptable error between experimental and numerical works .

  9. Effect of acetic acid on corrosion behavior of AISI 201, 304 and 430 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Vashishtha, Himanshu; Taiwade, Ravindra V.; Sharma, Sumitra [Visvesvaraya National Institute of Technology (VNIT), Nagpur (India). Dept. of Metallurgical and Materials Engineering

    2017-05-15

    Austenitic stainless steels are often used to handle organic acids such as acetic acid (CH{sub 3}COOH), which are extensively used in food contact applications and chemical industries for manufacturing medicines, nutrition and various chemical amalgams. In the present investigation an attempt has been made to compare the corrosion behavior of Cr-Ni (AISI type 304), Cr-Mn-Ni (type 201) and Cr (type 430) stainless steel for economical replacement of higher cost Cr-Ni grade. Immersion testing was performed at room temperature and boiling temperature in acetic acid. Atomic absorption spectroscopy was carried out to evaluate metal ion concentration in the immersion solution. The surface morphology of pit formation was characterized using scanning electron microscopy coupled with energy dispersive X-ray spectroscopy. The effect of elemental leaching on electrical conductivity of the immersion solution was evaluated and correlated with pH measurements. A new mechanism has been proposed for the pit formation due to manganese sulfide inclusions. The replacement compatibility was further confirmed with anodic polarization testing and a successful replacement was established for room temperature applications.

  10. Austenitic Stainless Steel AISI 316L Corrosion Test Research%奥氏体不锈钢AISI 316L腐蚀试验研究

    Institute of Scientific and Technical Information of China (English)

    王金刚; 刘江涛; 程珊珊

    2014-01-01

    在精对苯二甲酸(PTA)生产中,选取干燥机BM302壳体常用材料奥氏体不锈钢AISI 316L为研究对象,在醋酸环境中,对AISI 316L 受Br-及Cl-作用的电化学极化试验和电化学阻抗试验进行腐蚀性试验研究。试验结果表明,Br-或Cl-浓度的增加都会导致AISI 316L不锈钢腐蚀速率增加、击穿电位降低、腐蚀反应电阻减小,导致其耐腐蚀性能下降,腐蚀加剧。为PTA设备腐蚀的现场监测和设备维护提供参考依据。%In purified terephthalic acid (PTA) production, selected the drying machine BM302 shell commonly use material austenitic stainless steel AISI 316L as the research object. In the acetic acid environment, for corrosive test research of AISI 316L, through Br-and Cl-the role of electrochemical polarization test and electrochemical impedance test. The test results show that Br-or Cl-will lead to the increasing of the concentration of seawater AISI 316L stainless steel corrosion rate increase, breakdown voltage is reduced, and the corrosion reaction resistance decreases, and lead to its corrosion resistance drop, corrosion intensifies. That will provide reference for PTA equipment corrosion field monitoring and equipment maintenance.

  11. COCHLEAR IMPLANTATION: MY EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Shankar

    2015-12-01

    Full Text Available Cochlear implant is a small, surgically implanted complex electronic device that can help to provide a sense of sound to a person with severe to profound sensorineural hearing loss. This type of hearing loss, typically involves damage to hair cells in the cochlea, as a result sound cannot reach the auditory nerve which usually receives information from hair cells. A cochlear implant skips the damaged hair cells and to stimulate the auditory nerve directly. An implant does not restore normal hearing, instead it can give a deaf person a useful representation of sounds in the environment and help him or her to understand speech. I am here presenting this article in relation to the indications, intraoperative and postoperative complications of cochlear implantation in our institute since January 2013. Children who receive implants at earlier age, outperform their peers who are implanted at a later age. This is reflected in all the areas of speech and language development.

  12. Effects of X-rays Radiation on AISI 304 Stainless Steel Weldings with AISI 316L Filler Material: A Study of Resistance and Pitting Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    Francisco Javier Cárcel-Carrasco

    2016-04-01

    Full Text Available This article investigates the effect of low-level ionizing radiation, namely X-rays, on the micro structural characteristics, resistance, and corrosion resistance of TIG-welded joints of AISI 304 austenitic stainless steel made using AISI 316L filler rods. The welds were made in two different environments: natural atmospheric conditions and a closed chamber filled with inert argon gas. The influence of different doses of radiation on the resistance and corrosion characteristics of the welds is analyzed. Welded material from inert Ar gas chamber TIG showed better characteristics and lesser irradiation damage effects.

  13. Corrosion and microstructural analysis data for AISI 316L and AISI 347H stainless steels after exposure to a supercritical water environment.

    Science.gov (United States)

    Ruiz, A; Timke, T; van de Sande, A; Heftrich, T; Novotny, R; Austin, T

    2016-06-01

    This article presents corrosion data and microstructural analysis data of austenitic stainless steels AISI 316L and AISI 347H exposed to supercritical water (25 MPa, 550 °C) with 2000 ppb of dissolved oxygen. The corrosion tests lasted a total of 1200 h but were interrupted at 600 h to allow measurements to be made. The microstructural data have been collected in the grain interior and at grain boundaries of the bulk of the materials and at the superficial oxide layer developed during the corrosion exposure.

  14. Corrosion and microstructural analysis data for AISI 316L and AISI 347H stainless steels after exposure to a supercritical water environment

    Directory of Open Access Journals (Sweden)

    A. Ruiz

    2016-06-01

    Full Text Available This article presents corrosion data and microstructural analysis data of austenitic stainless steels AISI 316L and AISI 347H exposed to supercritical water (25 MPa, 550 °C with 2000 ppb of dissolved oxygen. The corrosion tests lasted a total of 1200 h but were interrupted at 600 h to allow measurements to be made. The microstructural data have been collected in the grain interior and at grain boundaries of the bulk of the materials and at the superficial oxide layer developed during the corrosion exposure.

  15. Physical properties of the AISI 348 L{sup *} austenitic stainless steel; Propriedades fisicas do aco inoxidavel austenitico AISI 348 L{sup *}

    Energy Technology Data Exchange (ETDEWEB)

    Teodoro, Celso Antonio; Lucki, Georgi; Silva, Jose Eduardo Rosa da; Terremoto, Luis Antanio Albiac; Castanheira, Myrthes; Damy, Margaret de Almeida [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: cteodoro@ipen.br

    2005-07-01

    The study of radiation damage in metals and alloys, used as structural materials of nuclear reactors has a strategic meaning in nuclear technology, because it allows the performance evaluation of these materials in working conditions of PWR. For this sake it is necessary to know the detrimental structural changes that occur during fast neutron irradiation. The aim of the present work is to show some strain-stress results of the AISI 348 L{sup *} stainless steel utilized as a structural material of the fuel elements of PWR, in comparison with the AISI 304. (author)

  16. In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

    Science.gov (United States)

    Gupta, Sonam; Narayan, Aparna Ichalangod; Balakrishnan, Dhanasekar

    2017-01-01

    Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n = 5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p > 0.05) was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.

  17. Comparative study of pulsed Nd:YAG laser welding of AISI 304 and AISI 316 stainless steels

    Science.gov (United States)

    Kumar, Nikhil; Mukherjee, Manidipto; Bandyopadhyay, Asish

    2017-02-01

    Laser welding is a potentially useful technique for joining two pieces of similar or dissimilar materials with high precision. In the present work, comparative studies on laser welding of similar metal of AISI 304SS and AISI 316SS have been conducted forming butt joints. A robotic control 600 W pulsed Nd:YAG laser source has been used for welding purpose. The effects of laser power, scanning speed and pulse width on the ultimate tensile strength and weld width have been investigated using the empirical models developed by RSM. The results of ANOVA indicate that the developed models predict the responses adequately within the limits of input parameters. 3-D response surface and contour plots have been developed to find out the combined effects of input parameters on responses. Furthermore, microstructural analysis as well as hardness and tensile behavior of the selected weld of 304SS and 316SS have been carried out to understand the metallurgical and mechanical behavior of the weld. The selection criteria are based on the maximum and minimum strength achieved by the respective weld. It has been observed that the current pulsation, base metal composition and variation in heat input have significant influence on controlling the microstructural constituents (i.e. phase fraction, grain size etc.). The result suggests that the low energy input pulsation generally produce fine grain structure and improved mechanical properties than the high energy input pulsation irrespective of base material composition. However, among the base materials, 304SS depict better microstructural and mechanical properties than the 316SS for a given parametric condition. Finally, desirability function analysis has been applied for multi-objective optimization for maximization of ultimate tensile strength and minimization of weld width simultaneously. Confirmatory tests have been conducted at optimum parametric conditions to validate the optimization techniques.

  18. [2- to 5-year follow-up of cementless implantable knee joint prosthesis of the Miller-Galante type].

    Science.gov (United States)

    Kienapfel, H; Griss, P; Orth, J; Roloff, K; Malzer, U

    1991-06-01

    Based on a prospective study protocol, the two- to five-year results of the Miller-Galante cementless total knee arthroplasty are presented. Sixty-four implants were placed in 59 patients: 60 implantations were cementless and 4 cemented. Clinically, the scores for pain, range of motion, walking and stair climbing improved significantly. Radiographically, the uncemented components displayed no signs of definite or possible loosening, whereas one of the cemented components was found to be definitely loose. On histological evaluation of the retrieved implants, all components had bone ingrowth.

  19. An Anti-Coagulation Conundrum: Implantation of Total Artificial Heart in a Patient with Heparin-Induced Thrombocytopenia Type II

    Science.gov (United States)

    Cios, Theodore J.; Salamanca-Padilla, Yuliana; Guvakov, Dmitri

    2017-01-01

    Patient: Male, 44 Final Diagnosis: Heparin-induced thrombocytopenia Type II Symptoms: Congestive heart failure • short of breath Medication: — Clinical Procedure: LVAD explantation • TAH insertion Specialty: Anesthesiology Objective: Rare co-existance of disease or pathology Background: Heparin-induced thrombocytopenia (HIT) is a rare but life-threatening complication of heparin administration. It can present a major clinical dilemma for physicians caring for patients requiring life-saving urgent or emergent cardiac surgery. Studies have been published examining the use of alternative anticoagulants for patients undergoing cardiopulmonary bypass (CPB), however, evidence does not clearly support any particular approach. Presently, there are no large-scale, prospective randomized studies examining the impact of alternative anticoagulants on clinical outcomes for HIT-positive patients requiring cardiac surgery. Case Report: We present the case of a patient who underwent SynCardia Total Artificial Heart (TAH) implantation following a recent left ventricular assist device (LVAD) placement. The patient was receiving argatroban for type II HIT with anuric renal failure, and developed a thrombus which occluded the inflow cannula of the LVAD. Based on a published study and after establishing consensus with the surgical, anesthesiology, perfusion, and hematology teams, we decided to use tirofiban as an antiplatelet agent to inhibit the platelet aggregation induced by heparin, and ultimately used heparin as the anticoagulant for cardiopulmonary bypass. Conclusions: When selecting anticoagulation for a HIT-positive patient requiring CPB, so that benefits outweigh risks, it is of paramount importance that the decision be based on a multitude of factors. The team caring for the patient should have a shared mental model and be familiar with the pharmacology, devices used, and local practices. These three elements should be integrated with patient-specific comorbidities

  20. Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick type artificial lumbar disc (Medtronic Sofamor Danek).

    Science.gov (United States)

    Zeh, Alexander; Becker, Claudia; Planert, Michael; Lattke, Peter; Wohlrab, David

    2009-06-01

    In total hip endoprosthetics and consequently for TDA, metal-on-metal combinations are used with the aim of reducing wear debris. In metal-on-metal TDA the release of metal ions has until now been secondary to the main discussion. In order to investigate the ion release following the implantation of the metal-on-metal Maverick type artificial lumbar disc we measured the serum cobalt and chromium concentration following implantation of 15 Maverick TDAs (monosegmental L5/S1, n = 5; bisegmental L4/5 and L5/S1, n = 5; average age 36.5 years). Five healthy subjects (no metal implants) acted as a control group. The two measurements of the metals were carried out using the absorption spectrometry after an average of 14.8 and 36.7 months. In summary, the concentrations of cobalt and chromium ions in the serum at both follow-ups amounted on average to 3.3 microg/l (SD 2.6) for cobalt and 2.2 microg/l (SD 1.5) for chromium. These figures are similar to the figures shown in the literature following the implantation of metal-on-metal THA. After a comparison to the control group, both the chromium and cobalt levels in the serum showed visible increases regarding the first and the second follow-up. As there is still a significant release of cobalt and chromium into the serum after an average follow-up of 36.7 months a persistent release of these ions must be taken into consideration. Despite the evaluation of the systemic and local effects of the release of Cr/Co from orthopaedic implants has not yet been concluded, one should take into consideration an explanation given to patients scheduled for the implantation of a metal-on-metal TDA about these results and the benefits/risks of alternative combinations of gliding contact surfaces.

  1. Vacancy-related defects in n-type Si implanted with a rarefied microbeam of accelerated heavy ions in the MeV range

    Energy Technology Data Exchange (ETDEWEB)

    Capan, I. [Rudjer Boskovic Institute, Bijenička 54, 10000 Zagreb (Croatia); Pastuović, Ž., E-mail: zkp@ansto.gov.au [Center for Accelerator Science, ANSTO, Locked bag 2001, Kirrawee Dc, NSW 2232 (Australia); Siegele, R. [Center for Accelerator Science, ANSTO, Locked bag 2001, Kirrawee Dc, NSW 2232 (Australia); Jaćimović, R. [Jozef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana (Slovenia)

    2016-04-01

    Deep level transient spectroscopy (DLTS) has been used to study vacancy-related defects formed in bulk n-type Czochralski-grown silicon after implantation of accelerated heavy ions: 6.5 MeV O, 10.5 MeV Si, 10.5 MeV Ge, and 11 MeV Er in the single ion regime with fluences from 10{sup 9} cm{sup −2} to 10{sup 10} cm{sup −2} and a direct comparison made with defects formed in the same material irradiated with 0.7 MeV fast neutron fluences up to 10{sup 12} cm{sup −2}. A scanning ion microprobe was used as the ion implantation tool of n-Cz:Si samples prepared as Schottky diodes, while the ion beam induced current (IBIC) technique was utilized for direct ion counting. The single acceptor state of the divacancy V{sub 2}(−/0) is the most prominent defect state observed in DLTS spectra of n-CZ:Si samples implanted by selected ions and the sample irradiated by neutrons. The complete suppression of the DLTS signal related to the double acceptor state of divacancy, V{sub 2}(=/−) has been observed in all samples irradiated by ions and neutrons. Moreover, the DLTS peak associated with formation of the vacancy-oxygen complex VO in the neutron irradiated sample was also completely suppressed in DLTS spectra of samples implanted with the raster scanned ion microbeam. The reason for such behaviour is twofold, (i) the local depletion of the carrier concentration in the highly disordered regions, and (ii) the effect of the microprobe-assisted single ion implantation. The activation energy for electron emission for states assigned to the V{sub 2}(−/0) defect formed in samples implanted by single ions follows the Meyer–Neldel rule. An increase of the activation energy is strongly correlated with increasing ion mass.

  2. Vacancy-related defects in n-type Si implanted with a rarefied microbeam of accelerated heavy ions in the MeV range

    Science.gov (United States)

    Capan, I.; Pastuović, Ž.; Siegele, R.; Jaćimović, R.

    2016-04-01

    Deep level transient spectroscopy (DLTS) has been used to study vacancy-related defects formed in bulk n-type Czochralski-grown silicon after implantation of accelerated heavy ions: 6.5 MeV O, 10.5 MeV Si, 10.5 MeV Ge, and 11 MeV Er in the single ion regime with fluences from 109 cm-2 to 1010 cm-2 and a direct comparison made with defects formed in the same material irradiated with 0.7 MeV fast neutron fluences up to 1012 cm-2. A scanning ion microprobe was used as the ion implantation tool of n-Cz:Si samples prepared as Schottky diodes, while the ion beam induced current (IBIC) technique was utilized for direct ion counting. The single acceptor state of the divacancy V2(-/0) is the most prominent defect state observed in DLTS spectra of n-CZ:Si samples implanted by selected ions and the sample irradiated by neutrons. The complete suppression of the DLTS signal related to the double acceptor state of divacancy, V2(=/-) has been observed in all samples irradiated by ions and neutrons. Moreover, the DLTS peak associated with formation of the vacancy-oxygen complex VO in the neutron irradiated sample was also completely suppressed in DLTS spectra of samples implanted with the raster scanned ion microbeam. The reason for such behaviour is twofold, (i) the local depletion of the carrier concentration in the highly disordered regions, and (ii) the effect of the microprobe-assisted single ion implantation. The activation energy for electron emission for states assigned to the V2(-/0) defect formed in samples implanted by single ions follows the Meyer-Neldel rule. An increase of the activation energy is strongly correlated with increasing ion mass.

  3. Association of Psychiatric History and Type D Personality with Symptoms of Anxiety, Depression, and Health Status Prior to ICD Implantation

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Kraaier, Karin; Pedersen, Susanne S.; Hout, Moniek; Scholten, Marcoen; Palen, van der Job

    2013-01-01

    BACKGROUND: Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD). PURPOSE: We examined associations between previous anxiety and depressive diso

  4. Effect of Masticatory Forces Transmitted by Dental Implants on the Mandibular Bone of Patients with Type 2 Diabetes Mellitus

    OpenAIRE

    Juncar Raluca-Iulia; Juncar Mihai; Gligor Florin-Onişor; Popa Amorin-Remus

    2015-01-01

    Background and Aims: Diabetes mellitus is considered to be one of the most important diseases of our society, affecting a considerable proportion of the adult population. Currently, dental implant treatment of diabetic patients is controversial, the main controversy being related to changes that occur in the jaw bones of the diabetic patient and the ensuing side effects. This preliminary study aims to evaluate the response of mandibular bone to masticatory forces transmitted by dental implant...

  5. Effect of Masticatory Forces Transmitted by Dental Implants on the Mandibular Bone of Patients with Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Juncar Raluca-Iulia

    2015-12-01

    Full Text Available Background and Aims: Diabetes mellitus is considered to be one of the most important diseases of our society, affecting a considerable proportion of the adult population. Currently, dental implant treatment of diabetic patients is controversial, the main controversy being related to changes that occur in the jaw bones of the diabetic patient and the ensuing side effects. This preliminary study aims to evaluate the response of mandibular bone to masticatory forces transmitted by dental implants in diabetic patients. Material and Method: 11 dental implants placed in the mandible were selected, and mandibular bone resorption as a result of masticatory forces transmitted by them was evaluated. Results: The mean bone resorption rates were the following: 2.72% at the time of dental implant exposure, 10% at 3 months from dental implant exposure, and 13.63% at 6 months from exposure. Conclusions: No significant changes in mandibular bone response to the action of dental implants were found in diabetic patients compared to standard response reported in non-diabetic patients.

  6. Dental Implants.

    Science.gov (United States)

    Griggs, Jason A

    2017-10-01

    Systematic reviews of literature over the period between 2008 and 2017 are discussed regarding clinical evidence for the factors affecting survival and failure of dental implants. The factors addressed include publication bias, tooth location, insertion torque, collar design, implant-abutment connection design, implant length, implant width, bone augmentation, platform switching, surface roughness, implant coatings, and the use of ceramic materials in the implant body and abutment. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Microstructural characterization of an AISI-SAE 4140 steel without nitridation and nitrided; Caracterizacion microestructural de un acero AISI-SAE 4140 sin nitrurar y nitrurado

    Energy Technology Data Exchange (ETDEWEB)

    Medina F, A.; Naquid G, C. [Gerencia de Ciencia de Materiales, Depto. de Sintesis y Caracterizacion de Materiales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    It was micro structurally characterized an AISI-SAE 4140 steel before and after of nitridation through the nitridation process by plasma post-unloading microwaves through Optical microscopy (OM), Scanning electron microscopy (SEM) by means of secondary electrons and retrodispersed, X-ray diffraction (XRD), Energy dispersion spectra (EDS) and mapping of elements. (Author)

  8. Augmentation of the mandible via a "tent-pole" procedure and implant treatment in a patient with type III osteogenesis imperfecta: clinical and histologic considerations.

    Science.gov (United States)

    Wannfors, Karin; Johansson, Carina; Donath, Karl

    2009-01-01

    The present report describes the oral rehabilitation of a female patient suffering from type III osteogenesis imperfecta. Agenesis of the mandibular anterior teeth and malocclusion caused partly by heavily worn teeth made dental rehabilitation necessary. Before a decision to use implants following a grafting procedure, the osseointegration of microimplants was tested. After 4 and 12 months, bone plugs containing two microimplants were retrieved from the patient. Histologic evaluation showed very sparse/poor osseointegration, and the healing time seemed to be much longer than normal. A decision was made to use the "tent-pole" procedure described by Marx et al, followed by prolonged healing. Surgery was uneventful, and the patient was provided with four implants that were partly covered with bone obtained from the iliac crest. Platelet-rich plasma was used to accelerate bone healing. After 9 months, the implants were uncovered and the prosthetic construction was completed. The implant-supported metal-ceramic restoration was serving well at the 1-year and 3-year follow-ups. Minimal resorption of marginal bone was detected during the first year.

  9. Back-junction back-contact n-type silicon solar cell with diffused boron emitter locally blocked by implanted phosphorus

    Science.gov (United States)

    Müller, Ralph; Schrof, Julian; Reichel, Christian; Benick, Jan; Hermle, Martin

    2014-09-01

    The highest energy conversion efficiencies in the field of silicon-based photovoltaics have been achieved with back-junction back-contact (BJBC) silicon solar cells by several companies and research groups. One of the most complex parts of this cell structure is the fabrication of the locally doped p- and n-type regions, both on the back side of the solar cell. In this work, we introduce a process sequence based on a synergistic use of ion implantation and furnace diffusion. This sequence enables the formation of all doped regions for a BJBC silicon solar cell in only three processing steps. We observed that implanted phosphorus can block the diffusion of boron atoms into the silicon substrate by nearly three orders of magnitude. Thus, locally implanted phosphorus can be used as an in-situ mask for a subsequent boron diffusion which simultaneously anneals the implanted phosphorus and forms the boron emitter. BJBC silicon solar cells produced with such an easy-to-fabricate process achieved conversion efficiencies of up to 21.7%. An open-circuit voltage of 674 mV and a fill factor of 80.6% prove that there is no significant recombination at the sharp transition between the highly doped emitter and the highly doped back surface field at the device level.

  10. Back-junction back-contact n-type silicon solar cell with diffused boron emitter locally blocked by implanted phosphorus

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Ralph, E-mail: ralph.mueller@ise.fraunhofer.de; Schrof, Julian; Reichel, Christian; Benick, Jan; Hermle, Martin [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, Freiburg D-79110 (Germany)

    2014-09-08

    The highest energy conversion efficiencies in the field of silicon-based photovoltaics have been achieved with back-junction back-contact (BJBC) silicon solar cells by several companies and research groups. One of the most complex parts of this cell structure is the fabrication of the locally doped p- and n-type regions, both on the back side of the solar cell. In this work, we introduce a process sequence based on a synergistic use of ion implantation and furnace diffusion. This sequence enables the formation of all doped regions for a BJBC silicon solar cell in only three processing steps. We observed that implanted phosphorus can block the diffusion of boron atoms into the silicon substrate by nearly three orders of magnitude. Thus, locally implanted phosphorus can be used as an in-situ mask for a subsequent boron diffusion which simultaneously anneals the implanted phosphorus and forms the boron emitter. BJBC silicon solar cells produced with such an easy-to-fabricate process achieved conversion efficiencies of up to 21.7%. An open-circuit voltage of 674 mV and a fill factor of 80.6% prove that there is no significant recombination at the sharp transition between the highly doped emitter and the highly doped back surface field at the device level.

  11. Selective laser melting of Fe-Ni-Cr layer on AISI H13 tool steel

    Institute of Scientific and Technical Information of China (English)

    Byeong-Don JOO; Jeong-Hwan JANG; Jae-Ho LEE; Young-Myung SON; Young-Hoon MOON

    2009-01-01

    An attempt to fabricate Fe-Ni-Cr coating on AISI H13 tool steel was performed with selective laser melting. Fe-Ni-Cr coating was produced by experimental facilities consisting of a 200 W fiber laser which can be focused to 80 μm and atmospheric chamber which can control atmospheric pressure with N2 or Ar. Coating layer was fabricated with various process parameters such as laser power, scan rate and fill spacing. Surface quality and coating thickness were measured and analyzed. Three different surface patterns, such as typeⅠ, typeⅡand type Ⅲ, are shown with various test conditions and smooth regular pattern is obtained under the conditions as 10 μm of fill spacing, 50-350 mm/s of scan rate and 40 μm of fill spacing, 10-150 mm/s of scan rate. The maximum coating thickness is increased with power elevation or scan rate drop, and average thickness of 10 μm fill spacing is lower than that of 40 μm fill spacing.

  12. Influence of post irradiation annealing on the mechanical properties and defect structure of AISI 304 steel

    Energy Technology Data Exchange (ETDEWEB)

    Van Renterghem, W.; Van Dyck, S. [SCK-CEN, Mol (Belgium); Al Mazouzi, A. [EDF, Site les renardieres, Moret-sur-Loing (France)

    2011-07-01

    The effect of post irradiation annealing on the mechanical properties and the radiation induced defect structure was investigated on stainless steel, of type AISI 304, that was irradiated up to 24 dpa in the decommissioned Chooz A reactor. The material has been investigated both in the as-irradiated state as well as after post irradiation annealing. In the as-irradiated specimen the typical radiation induced defects were found as well as precipitates, most probably (Ni3Si), are present. Martensite phases with a bcc crystal structure were found near the grain boundaries. Annealing at 400 C had almost no effect on the radiation induced defects, but annealing at 500 C resulted in the immediate un-faulting of the Frank loops. As to the mechanical properties, annealing at 400 C did not strongly affect the yield strength and the ductility of the material, although the fraction of intergranular fracture during slow strain rate tensile tests (SSRT), under pressurised water reactor (PWR) condition, was significantly reduced. Annealing at 500 C did reduce the yield strength and restored substantially the ductility and the strain hardening capability of the material. The microstructure investigated by transmission electron microscopy correlates to the mechanical test results. It was found that the observed defect changes after post irradiation annealing provide a reasonable explanation for the observed changes of the mechanical properties obtained from SSRT under PWR chemical conditions. (authors)

  13. Influence of post irradiation annealing on the mechanical properties and defect structure of AISI 304 steel

    Energy Technology Data Exchange (ETDEWEB)

    Van Renterghem, W., E-mail: wvrenter@sckcen.be [SCK-CEN, Nuclear Materials Science, Boeretang 200, 2400 Mol (Belgium); Al Mazouzi, A.; Van Dyck, S. [SCK-CEN, Nuclear Materials Science, Boeretang 200, 2400 Mol (Belgium)

    2011-06-15

    The effect of post irradiation annealing on the mechanical properties and the radiation induced defect structure was investigated on stainless steel, of type AISI 304, that was irradiated up to 24 dpa in the decommissioned Chooz A reactor. The material was investigated both in the as-irradiated state as well as after post irradiation annealing. In the as-irradiated specimen the typical radiation induced defects were found as well as {gamma}'-precipitates (Ni{sub 3}Si). Annealing at 400 deg. C had almost no effect on the radiation induced defects, but annealing at 500 deg. C resulted in the immediate unfaulting of the Frank loops. As to the mechanical properties, annealing at 400 deg. C did not strongly affect the yield strength and the ductility of the material, although the fraction of intergranular fracture during slow strain rate tensile tests under pressurised water reactor conditions, was significantly reduced. Annealing at 500 deg. C did reduce the yield strength and restored substantially the ductility and the strain hardening capability of the material. The microstructure investigated by transmission electron microscopy correlates to the mechanical test results. It was found that the observed defect changes after post irradiation annealing provide a reasonable explanation for the observed changes of the mechanical properties.

  14. Plasma nitriding of AISI 52100 ball bearing steel and effect of heat treatment on nitrided layer

    Indian Academy of Sciences (India)

    Ravindra Kumar; J Alphonsa; Ram Prakash; K S Boob; J Ghanshyam; P A Rayjada; P M Raole; S Mukherjee

    2011-02-01

    In this paper an effort has been made to plasma nitride the ball bearing steel AISI 52100. The difficulty with this specific steel is that its tempering temperature (∼170–200°C) is much lower than the standard processing temperature (∼460–580°C) needed for the plasma nitriding treatment. To understand the mechanism, effect of heat treatment on the nitrided layer steel is investigated. Experiments are performed on three different types of ball bearing races i.e. annealed, quenched and quench-tempered samples. Different gas compositions and process temperatures are maintained while nitriding these samples. In the quenched and quench-tempered samples, the surface hardness has decreased after plasma nitriding process. Plasma nitriding of annealed sample with argon and nitrogen gas mixture gives higher hardness in comparison to the hydrogen–nitrogen gas mixture. It is reported that the later heat treatment of the plasma nitrided annealed sample has shown improvement in the hardness of this steel. X-ray diffraction analysis shows that the dominant phases in the plasma nitrided annealed sample are (Fe2−3N) and (Fe4N), whereas in the plasma nitrided annealed sample with later heat treatment only -Fe peak occurs.

  15. Effects of nitrogen and pulsed mean welding current in AISI 316 austenitic stainless steel solidification cracks; Efecto del nitrogeno y la corriente media pulsada de soldadura en la formacion de grietas de solidificacion en aceros inoxidables AISI 316L

    Energy Technology Data Exchange (ETDEWEB)

    Trevisan, R. E.; Braga, E.; Fals, H. C.

    2002-07-01

    An analysis of the influence of nitrogen concentration in the weld zone and the pulsed mean welding current in the solidification crack formation is presented in this paper. The AISI 316L austenitic stainless steel was employed as the metal base. The welding was done using CC+ pulsed flux cored are welding process and AWS E316L wire type. The tests were conducted using CO{sub 2} shielding gas with four different nitrogen levels (0,5; 10 and 15%) in order to induce different nitrogen weld metal concentrations. The pulsed mean welding current was varied in three levels and the. Transvarestraint tangential strain test was fixed of 5%. The results showed that the solidification cracking decreased as the pulsed mean welding current increase. It was also verified that an increase of the weld zone nitrogen level was associated with a decrease in both the total length of solidification crack and the amount of {delta} ferrite. (AUthor) 20 refs.

  16. Biomechanical evaluation of macro and micro designed screw-type implants: an insertion torque and removal torque study in rabbits.

    Science.gov (United States)

    Chowdhary, Ramesh; Jimbo, Ryo; Thomsen, Christian; Carlsson, Lennart; Wennerberg, Ann

    2013-03-01

    To investigate the combined effect of macro and pitch shortened threads on primary and secondary stability during healing, but before dynamic loading. Two sets of turned implants with different macro geometry were prepared. The test group possessed pitch shortened threads in between the large threads and the control group did not have thread alterations. The two implant groups were placed in both femur and tibiae of 10 lop-eared rabbits, and at the time of implant insertion, insertion torques were recorded. After 4 weeks, all implants were subjected to removal torque tests. The insertion torque values for the control and test groups for the tibia were 15.7 and 20.6 Ncm, respectively, and for the femur, 11.8, and 12.8 Ncm respectively. The removal torque values for the control and test groups in the tibia were 7.9 and 9.1 Ncm, respectively, and for the femur, 7.9 and 7.7 Ncm respectively. There was no statistically significant difference between the control and test groups. Under limited dynamic load, the addition of pitch shortened threads did not significantly improve either the primary or the secondary stability of the implants in bone. © 2011 John Wiley & Sons A/S.

  17. Nitriding Process Characterization of Cold Worked AISI 304 and 316 Austenitic Stainless Steels

    Directory of Open Access Journals (Sweden)

    Waldemar Alfredo Monteiro

    2017-01-01

    Full Text Available The nitriding behavior of austenitic stainless steels (AISI 304 and 316 was studied by different cold work degree (0% (after heat treated, 10%, 20%, 30%, and 40% before nitride processing. The microstructure, layer thickness, hardness, and chemical microcomposition were evaluated employing optical microscopy, Vickers hardness, and scanning electron microscopy techniques (WDS microanalysis. The initial cold work (previous plastic deformations in both AISI 304 and 306 austenitic stainless steels does not show special influence in all applied nitriding kinetics (in layer thicknesses. The nitriding processes have formed two layers, one external layer formed by expanded austenite with high nitrogen content, followed by another thinner layer just below formed by expanded austenite with a high presence of carbon (back diffusion. An enhanced diffusion can be observed on AISI 304 steel comparing with AISI 316 steel (a nitrided layer thicker can be noticed in the AISI 304 steel. The mechanical strength of both steels after nitriding processes reveals significant hardness values, almost 1100 HV, on the nitrided layers.

  18. Wear properties of niobium carbide coatings performed by pack method on AISI 1040 steel

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ugur [Sakarya University, Technical Education Faculty, Department of Metal Education, 54187 Sakarya (Turkey)]. E-mail: ugursen@sakarya.edu.tr

    2005-07-01

    A series of experiments was performed to evaluate tribological properties of niobium carbide coated AISI 1040 steel. In coating process, thermo-reactive diffusion treatment by pack method was performed at the temperatures of 800, 900 and 1000 deg. C for 1-4 h, respectively. Depending on coating process time and temperature, the thickness of niobium carbide layer formed on substrate ranged from 3.4{+-}0.5 to 12{+-}2 {mu}m. The hardness of niobium carbide layers on the steel sample is 1792 HV. The presence of carbides (e.g. NbC, Nb{sub 2}C) formed on the surface of coated AISI 1040 steel was confirmed by X-ray diffraction analysis. Dry wear tests for uncoated and coated AISI 1040 steel against AISI D2 steel were carried out on pin-on-disk configuration and at sliding speed range of 0.5, 1, 2 and 5 m/s, and under 15 N and 30 N loads. The results showed that the average coefficient of friction for coated and uncoated AISI 1040 steel were 0.3 and 0.5, respectively. The specific wear rates for uncoated and coated steel are 4.47x10{sup -5} mm{sup 3}/N.m to 4.29x10{sup -4} and 4.37x10{sup -7} to 3.55x10{sup -5} mm{sup 3}/N.m.

  19. Plasma post oxidation of nitrocarburized AISI 4140 steel

    Institute of Scientific and Technical Information of China (English)

    LEE Insup

    2006-01-01

    Plasma nitrocarburizing and plasma oxidizing treatments were performed to improve the wear and corrosion resistance of AISI 4140 steel.Plasma nitrocarburizing was conducted for 3 h at 570 ℃ in the nitrogen, hydrogen and methane atmosphere to produce the ε-Fe2-3(N,C) phase.It was found that the compound layer produced by plasma nitrocarburising was predominantly composed of ε-phase, with a small proportion of γ'-Fe4(N,C) phase.The thickness of the compound layer was about 10 μm and the diffusion layer was about 300 μm in thickness, respectively.Plasma post oxidation was performed on the nitrocarburized samples with various oxygen/hydrogen ratio at a constant temperature of 500 ℃ for 1 h.The very thin magnetite (Fe3O4) layer 1-2 μm in thickness on top of the compound layer was obtained by plasma post oxidation.It was confirmed that the corrosion characteristics of the nitrocarburized compound layer can be further improved by the application of the superficial magnetite layer.

  20. AISI waste oxide recycling program. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Aukrust, E.; Downing, K.B.; Sarma, B.

    1995-08-01

    In March 1995 AISI completed a five-year, $60 million collaborative development program on Direct Steelmaking cost-shared by DOE under the Metals Initiative. This program defined an energy-efficient and environmentally-friendly technology to produce hot metal for steelmaking directly from coal and iron ore pellets without incurring the high capital costs and environmental problems associated with traditional coke oven and blast furnace technology. As it becomes necessary to replace present capacity, this new technology will be favored because of reduced capital costs, higher energy efficiency, and lower operating costs. In April 1994, having failed to move forward with a demonstration plant for direct ironmaking, despite substantial efforts by both Stelco and Geneva Steel, an alternative opportunity was sought to commercialize this new technology without waiting until existing ironmaking capacity needed to be replaced. Recycling and resource recovery of steel plant waste oxides was considered an attractive possibility. This led to approval of a ten-month, $8.3 million joint program with DOE on recycling steel plant waste oxides utilizing this new smelting technology. This highly successful trial program was completed in December 1994. The results of the pilot plant work and a feasibility study for a recycling demonstration plant are presented in this final technical report.

  1. Spontaneous Sealing of a Type Ia Endoleak after Ovation Stent Graft Implantation in a Patient with On-Label Aortic Neck Anatomy.

    Science.gov (United States)

    Pranteda, Chiara; Sirignano, Pasqualino; Capoccia, Laura; Mansour, Wassim; Montelione, Nunzio; Speziale, Francesco

    2016-07-01

    We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.

  2. Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir

    2016-01-01

    To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. Seven years after the initial repair, imaging surveillance revealed significant endoleak and brisk aneurysm sac expansion due to Type IIIb endoleak secondary to endograft limb fabric tear. This case illustrates the imperative role of imaging surveillance in detection of long-term endovascular aneurysm repair complications. Furthermore, we discuss exclusion of the graft tear with aortouniiliac stent grafting as the treatment for this complication.

  3. The significance of passivation treatments on AISI 314 foam pieces to be used as substrates for catalytic applications

    Energy Technology Data Exchange (ETDEWEB)

    Bortolozzi, J.P.; Banus, E.D.; Milt, V.G.; Gutierrez, L.B. [Instituto de Investigaciones en Catalisis y Petroquimica, INCAPE (FIQ, UNL-CONICET), Santiago del Estero 2829, 3000 Santa Fe (Argentina); Ulla, M.A., E-mail: mulla@fiq.unl.edu.ar [Instituto de Investigaciones en Catalisis y Petroquimica, INCAPE (FIQ, UNL-CONICET), Santiago del Estero 2829, 3000 Santa Fe (Argentina)

    2010-11-01

    Several properties of metallic foams such as their low density, high mechanical strength and good coefficients of heat and mass transfer make them attractive for applications in catalysis. Important modifications in the composition and morphology of the metallic foam surfaces can take place when they are submitted to treatments at high temperatures. These surface changes are due to the migration of some elements from the metallic core to the pore surface, thus inducing a passivation via an oxide layer formation. This new layer avoids further metallic segregation and generates a surface roughness, both effects having a significant impact on the catalytic coating quality. This work analyzes the effects of calcination temperature and time on the chemistry and morphology of the metallic surface corresponding to the AISI 314 stainless steel foams of 50 and 60 ppi. The chemical and morphological surface changes were characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Energy-Dispersive X-Ray (EDX) analysis and Laser Raman Spectroscopy (LRS). The application of high temperature treatments on AISI 314 foams promotes the formation of a surface layer containing chromium oxide and spinel-type compounds of chromium, iron and manganese. The optimum treatment temperature for this type of structures seems to be 900 deg. C because both the adhesion and thickness of the layer formed are adequate. For the sample with smaller pores (60 ppi) the optimal treatment time is close to 2 h and for that with larger pores (50 ppi) the recommended time is 20 h. Under these conditions, a compromise is found between adhesion, thickness and surface roughness, suitable for the subsequent deposition of catalytic material.

  4. Joining of Dissimilar alloy Sheets (Al 6063&AISI 304 during Resistance Spot Welding Process: A Feasibility Study for Automotive industry

    Directory of Open Access Journals (Sweden)

    Reddy Sreenivasulu

    2014-12-01

    Full Text Available Present design trends in automotive manufacture have shifted emphasis to alternative lightweight materials in order to achieve higher fuel efficiency and to bring down vehicle emission. Although some other joining techniques are more and more being used, spot welding still remains the primary joining method in automobile manufacturing so far. Spot welds for automotive applications should have a sufficiently large diameter, so that nugget pullout mode is the dominant failure mode. Interfacial mode is unacceptable due to its low load carrying and energy absorption capability. Strength tests with different static loading were performed in, to reveal the failure mechanisms for the lap-shear geometry and the cross-tension geometry. Based on the literature survey performed, venture into this work was amply motivated by the fact that a little research work has been conducted to joining of dissimilar materials like non ferrous to ferrous. Most of the research works concentrated on joining of different materials like steel to steel or aluminium alloy to aluminium alloy by resistance spot welding. In this work, an experimental study on the resistance spot weldability of aluminium alloy (Al 6063 and austenitic stainless steel (AISI304 sheets, which are lap joined by using a pedestal type resistance spot welding machine. Welding was conducted using a 45-deg truncated cone copper electrode with 10-mm face diameter. The weld nugget diameter, force estimation under lap shear test and T – peel test were investigated using digital type tensometer attached with capacitive displacement transducer (Mikrotech, Bangalore, Model: METM2000ER1. The results shows that joining of Al 6063 and AISI 304 thin sheets by RSW method are feasible for automotive structural joints where the loads are below 1000N act on them, it is observed that by increasing the spots per unit length, then the joint with standing strength to oppose failure is also increased linearly incase of

  5. Tribocorrosion Failure Mechanism of TiN/SiOx Duplex Coating Deposited on AISI304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Qiang Chen

    2016-11-01

    Full Text Available TiN/SiOx duplex coatings were synthesized on AISI304 stainless steel by plasma immersion ion implantation and deposition (PIIID followed by radio frequency magnetron sputtering (RFMS. The microstructure and tribocorrosion failure behaviors of the duplex coatings were investigated by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy, reciprocating-sliding tribometer, and electrochemical tests. The as-deposited duplex coating had a two-layered columnar growth structure consisting of face-centered cubic TiN and amorphous SiOx. Sliding tests showed that the TiN interlayer had good adhesion with the substrate, but the SiOx layer suffered from severe delamination failure. Friction force induced a number of micro-cracks in the coating, which provided channels for the diffusion of NaCl solution. The tribocorrosion test showed that the duplex coating exhibited a lower wear-performance in NaCl solution than in ambient atmosphere. Multi-scale chloride ion corrosion occurred simultaneously and substantially degraded the bonding strength of the columnar crystals or neighboring layers. Force-corrosion synergy damage eventually led to multi-degradation failure of the duplex coating. The presented results provide a comprehensive understanding of the tribocorrosion failure mechanism in coatings with duplex architecture.

  6. Correlation between surface physicochemical properties and the release of iron from stainless steel AISI 304 in biological media.

    Science.gov (United States)

    Hedberg, Yolanda; Karlsson, Maria-Elisa; Blomberg, Eva; Odnevall Wallinder, Inger; Hedberg, Jonas

    2014-10-01

    Stainless steel is widely used in biological environments, for example as implant material or in food applications, where adsorption-controlled ligand-induced metal release is of importance from a corrosion, health, and food safety perspective. The objective of this study was to elucidate potential correlations between surface energy and wettability of stainless steel surfaces and the release of iron in complexing biological media. This was accomplished by studying changes in surface energies calculated from contact angle measurements, surface oxide composition (X-ray photoelectron spectroscopy), and released iron (graphite furnace atomic absorption spectroscopy) for stainless steel grade AISI 304 immersed in fluids containing bovine serum albumin or citric acid, and non-complexing fluids such as NaCl, NaOH, and HNO3. It was shown that the surface wettability and polar surface energy components were all influenced by adventitious atmospheric carbon (surface contamination of low molecular weight), rather than differences in surface oxide composition in non-complexing solutions. Adsorption of both BSA and citrate, which resulted in ligand-induced metal release, strongly influenced the wettability and the surface energy, and correlated well with the measured released amount of iron.

  7. Surface fatigue life of CBN and vitreous ground carburized and hardened AISI 9310 spur gears

    Science.gov (United States)

    Townsend, Dennis P.; Patel, P. R.

    1988-01-01

    Spur gear surface endurance tests were conducted to investigate CBN ground AISI 9310 spur gears for use in aircraft applications, to determine their endurance characteristics and to compare the results with the endurance of standard vitreous ground AISI 9310 spur gears. Tests were conducted with VIM-VAR AISI 9310 carburized and hardened gears that were finish ground with either CBN or vitreous grinding methods. Test conditions were an inlet oil temeprature of 320 K (116 F), an outlet oil temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. The CBN ground gears exhibited a surface fatigue life that was slightly better than the vitreous ground gears. The subsurface residual stress of the CBN ground gears was approximately the same as that for the standard vitreous ground gears for the CBN grinding method used.

  8. Evolution of sensitization in stainless steel AISI 304; Evaluacion del grado de sensibilizacion en el acero ionxidable AISI 304

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, O.; Santos, G.

    2003-07-01

    Austenitic stainless steel, when heat-treated at 550-850 degree centigree became susceptible to intergranular corrosion in acids. this phenomenon, know as sensitization, it is result from the precipitation of chrome carbides in the grain boundary, making these areas less resistant to corrosion. Two different electrochemical reactivation tests are compared with a destructive test and related to the classification of its respective microstructures. It was established a quantitative methodology to evaluate the degree of sensitization in AISI 304and also to compare the correspondence of the results with the data of the automatic and portable EPR device for non-destructive field measurement of the degree of sensitization. The used electrochemical techniques were the EPR (Electrochemical Potentiokinetic Reactivation) or single loop test and the PRP (Pasivation Reactivation Potentiokinetic) or double loop test. The destructive test used was boiling, 120 h ferric sulfate-50% sulfuric acid, according to the standard practices ASTM A-262 practices B. The classifications of etch structures were according to the standard practices ASTM A-262 practices B. (Author)

  9. Macro design effects on stress distribution around implants: A photoelastic stress analysis

    Directory of Open Access Journals (Sweden)

    Serhat Emre Ozkir

    2012-01-01

    Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  10. Activated flux tungsten inert gas welding of 8 mm-thick AISI 304 austenitic stainless steel

    Institute of Scientific and Technical Information of China (English)

    刘观辉; 刘美华; 易耀勇; 张宇鹏; 罗子艺; 许磊

    2015-01-01

    AISI 304 stainless steel plates were welded with activated flux tungsten inert gas (A-TIG) method by utilizing self-developed activated flux. It is indicated from the experimental results that for 8 mm-thick AISI 304 stainless steel plate, weld joint of full penetration and one-side welding with good weld appearance can be obtained in a single pass without groove preparation by utilizing A-TIG welding. Moreover, activated flux powders do not cause significant effect on the microstructure of TIG weld and the mechanical properties of A-TIG weld joints are also superior to those of C-TIG (conventional TIG) welding.

  11. FLOW STRESS MODEL FOR HARD MACHINING OF AISI H13 WORK TOOL STEEL

    Institute of Scientific and Technical Information of China (English)

    H. Yan; J. Hua; R. Shivpuri

    2005-01-01

    An approach is presented to characterize the stress response of workpiece in hard machining,accounted for the effect of the initial workpiece hardness, temperature, strain and strain rate on flow stress. AISI H13 work tool steel was chosen to verify this methodology. The proposed flow stress model demonstrates a good agreement with data collected from published experiments.Therefore, the proposed model can be used to predict the corresponding flow stress-strain response of AISI H13 work tool steel with variation of the initial workpiece hardness in hard machining.

  12. Development of Flow Stress of AISI H13 Die Steel in Hard Machining

    Institute of Scientific and Technical Information of China (English)

    YAN Hong; QIAN Guohua; HU Qiang

    2007-01-01

    An approach was presented to characterize the stress response of workpiece in hard machining, accounting for the effect of the initial workpiece hardness in addition to temperature, strain and strain rate on flow stress in this paper. AISI H13 die steel was chosen to verify this methodology. The proposed flow stress model demonstrates a good agreement with experimental data. Therefore, the proposed model can be used to predict the corresponding flow stress-strain response of AISI H13 die steel with variation of the initial workpiece hardness in hard machining.

  13. The effect of thermal annealing on the adherence of $Al_2O_3$-films deposited by low-pressure, metal-organic, chemical-vapor deposition on AISI 304

    NARCIS (Netherlands)

    Haanappel, V.A.C.; Vendel, van de D.; Corbach, van H.D.; Fransen, T.; Gellings, P.J.

    1995-01-01

    Thin alumina films, deposited at 280°C by low-pressure, metal-organic, chemical-vapor deposition on stainless steel, type AISI 304, were annealed at 0.17 kPa in a nitrogen atmosphere for 2,4, and 17 hr at 600, 700, and 800°C. The effect of the annealing process on the adhesion of the thin alumina fi

  14. Characterization of defects in n-type 4H-SiC after high-energy N ion implantation by RBS-channeling and Raman spectroscopy

    Science.gov (United States)

    Kummari, Venkata C.; Reinert, Tilo; Jiang, Weilin; McDaniel, Floyd D.; Rout, Bibhudutta

    2014-08-01

    Implantation with 1 MeV N ions was performed at room temperature in n-type 4H-SiC (0 0 0 1) at four implantation fluences (or doses in dpa (displacements per atom) at the damage peak) of 1.5 × 1013 (0.0034), 7.8 × 1013 (0.018), 1.5 × 1014 (0.034), and 7.8 × 1014 (0.178) ions/cm2, respectively. The evolution of disorder was studied using Rutherford backscattering spectrometry in channeling mode (RBS-C), Raman spectroscopy, and optical transmission. The disorder in the Si sub-lattice was found to be less than 10% for the dpa of 0.0034 and 0.0178 and increased to 40% and 60% for the dpa of 0.034 and 0.178 respectively. The normalized Raman intensity In, shows disorder of 41%, 69%, 77% and 100% for the dpa of 0.0034, 0.0178, 0.034 and 0.178, respectively. In this paper, the characterization of the defects produced due to the nitrogen implantation in 4H-SiC are presented and the results are discussed.

  15. TH-C-19A-09: Quantification of Transmission and Backscatter Factors as a function of Distance to Inhomogeneity Interface for Three Types of Surgical Implant Plates

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D; Mills, M; Wang, B [University of Louisville, Louisville, KY (United States)

    2014-06-15

    Purpose: Carbon fiber materials have been increasingly used clinically, mainly in orthopedics, as an alternative to metallic implants because of their minimal artifacts on CT and MRI images. This study characterizes the transmission and backscatter property of carbon fiber plates (CarboFix Orthopedics, Herzeliya, Israel) with measurements for radiation therapy applications, and compares them to traditional Stainless Steel (SS) and Titanium (Ti) metal materials. Methods: For the transmission measurements, 1-mm-thick test plate was placed upstream from a plane parallel Markus chamber, separated by various thicknesses of polystyrene plates in 0.5 cm increments between 0 and 5 cm. With this setup, we quantified the radiation transmission as a function of distance to the inhomogeneity interface. The LINAC source to detector distance was maintained at 100 cm and 200 MU was delivered for each measurement. Two 3-cm solid water phantoms were placed at the top and bottom to provide build up. All the measurements were performed for 6 MV and 18 MV photons. The backscatter measurements had the identical setup, except that the test plate was downstream of the chamber from radiation. Results: The carbon fiber plates did not introduce any measureable inhomogeneity effect on the transmission and backscatter factor because of its low atomic number. In contrast, traditional metal implant materials caused up to 15% dose difference at upstream and 25% backscatter at downstream from radiation. Such differences decrease as the distance to the inhomogeneity interface increases and become unmeasurable at distance of 3 cm and 1 cm for upstream and downstream, respectively. Conclusion: A new type of carbon fiber implant plate was evaluated and found to have minimal inhomogeneity effect in MV radiation beams. Patients would benefit from a carbon based implant over metal for radiation therapy due to their minimal backscatter and imaging artifacts.

  16. The Experimental Investigation of The Effect of Machining Parameters on Burr Formation in Drilling of AISI D2 and AISI D3 Cold Work Steels

    Directory of Open Access Journals (Sweden)

    Yavuz Kaplan

    2011-06-01

    Full Text Available In this study, the effect of changing processing parameters on the burr formation ats the exit end of hole during the drilling process in milling machines of CNC (Computer Numerical Control was examined. . In experimental studies, cold work tool steels (AISI D2, 20 HRC and AISI D3, 28 HRC were drilling by HSS cutting tools with four different lengths in two different diameters (Ø 8 mm and Ø 10 mm. Three different cutting speeds (5 m/min, 10 m/min, 15 m/min and three different feed rates values (0.04 mm/rev, 0.05 mm/rev, 0.06 mm/rev were used in experiments. According to outcomes of the experiment, it was detected that burr height decreases depending on feed rates increase and burr height increases depending on the number of holes, cutting speed and material hardness.

  17. Osseointegration of Immediate Transalveolar Implants

    Directory of Open Access Journals (Sweden)

    Yoel González Beriau

    2016-02-01

    Full Text Available Background: osseointegration is critical to start prosthetic rehabilitation. Objective: to describe osseointegration of immediate transalveolar implants. Methods: a prospective case series study was conducted from January 2012 to December 2013. It included all patients (75 patients with 79 implants who attended the Prosthodontics service. Age, sex, osseointegration, cause of tooth loss, region of the implant, specific tooth, bone level and keratinized gingiva around the implant, were the variables studied. Frequency distribution and statistical analysis were used for data analysis. Results: females and patients aged 31 to 45 years predominated. Osseointegration was observed in 97.4% of the implants. Nearly all implants were placed in the premaxilla and posterior maxilla, specifically in the first bicuspids. In most patients, osseointegration with bone formation occurred at the implant collar and in the presence of completely keratinized tissue, with a statistically significant association between the two variables. Conclusion: rehabilitation treatment with this type of implant led to successful osseointegration in most cases studied.

  18. Effect of type of luting agents on stress distribution in the bone surrounding implants supporting a three-unit fixed dental prosthesis: 3D finite element analysis.

    Science.gov (United States)

    Ghasemi, Ehsan; Abedian, Alireza; Iranmanesh, Pedram; Khazaei, Saber

    2015-01-01

    Osseointegration of dental implants is influenced by many biomechanical factors that may be related to stress distribution. The aim of this study was to evaluate the effect of type of luting agent on stress distribution in the bone surrounding implants, which support a three-unit fixed dental prosthesis (FDP) using finite element (FE) analysis. A 3D FE model of a three-unit FDP was designed replacing the maxillary first molar with maxillary second premolar and second molar as the abutments using CATIA V5R18 software and analyzed with ABAQUS/CAE 6.6 version. The model was consisted of 465108 nodes and 86296 elements and the luting agent thickness was considered 25 μm. Three load conditions were applied on eight points in each functional cusp in horizontal (57.0 N), vertical (200.0 N) and oblique (400.0 N, θ = 120°) directions. Five different luting agents were evaluated. All materials were assumed to be linear elastic, homogeneous, time independent and isotropic. For all luting agent types, the stress distribution pattern in the cortical bone, connectors, implant and abutment regions was almost uniform among the three loads. Furthermore, the maximum von Mises stress of the cortical bone was at the palatal side of second premolar. Likewise, the maximum von Mises stress in the connector region was in the top and bottom of this part. Luting agents transfer the load to cortical bone and different types of luting agents do not affect the pattern of load transfer.

  19. Effect of type of luting agents on stress distribution in the bone surrounding implants supporting a three-unit fixed dental prosthesis: 3D finite element analysis

    Science.gov (United States)

    Ghasemi, Ehsan; Abedian, Alireza; Iranmanesh, Pedram; Khazaei, Saber

    2015-01-01

    Background: Osseointegration of dental implants is influenced by many biomechanical factors that may be related to stress distribution. The aim of this study was to evaluate the effect of type of luting agent on stress distribution in the bone surrounding implants, which support a three-unit fixed dental prosthesis (FDP) using finite element (FE) analysis. Materials and Methods: A 3D FE model of a three-unit FDP was designed replacing the maxillary first molar with maxillary second premolar and second molar as the abutments using CATIA V5R18 software and analyzed with ABAQUS/CAE 6.6 version. The model was consisted of 465108 nodes and 86296 elements and the luting agent thickness was considered 25 μm. Three load conditions were applied on eight points in each functional cusp in horizontal (57.0 N), vertical (200.0 N) and oblique (400.0 N, θ = 120°) directions. Five different luting agents were evaluated. All materials were assumed to be linear elastic, homogeneous, time independent and isotropic. Results: For all luting agent types, the stress distribution pattern in the cortical bone, connectors, implant and abutment regions was almost uniform among the three loads. Furthermore, the maximum von Mises stress of the cortical bone was at the palatal side of second premolar. Likewise, the maximum von Mises stress in the connector region was in the top and bottom of this part. Conclusion: Luting agents transfer the load to cortical bone and different types of luting agents do not affect the pattern of load transfer. PMID:25709676

  20. Structure and properties of the Stainless steel AISI 316 nitrided with microwave plasma; Estructura y propiedades del acero inoxidable AISI 316 nitrurado con plasmas de microondas

    Energy Technology Data Exchange (ETDEWEB)

    Becerril R, F

    1999-07-01

    In this work were presented the results obtained by nitridation on stainless steel AISI 316 using a plasma generated through a microwave discharge with an external magnetic field using several moistures hydrogen / nitrogen to form a plasma. The purpose of nitridation was to increase the surface hardness of stainless steel through a phase formation knew as {gamma}N which has been reported that produces such effect without affect the corrosion resistance proper of this material. (Author)

  1. N-type doping of BaSi{sub 2} epitaxial films by phosphorus ion implantation and thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Hara, Kosuke O., E-mail: k-hara@numse.nagoya-u.ac.jp [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Core Research for Evolutional Science and Technology, Japan Science and Technology Agency, Gobancho, Chiyoda, Tokyo 102-0076 (Japan); Hoshi, Yusuke [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Usami, Noritaka [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Core Research for Evolutional Science and Technology, Japan Science and Technology Agency, Gobancho, Chiyoda, Tokyo 102-0076 (Japan); Shiraki, Yasuhiro [Advanced Research Laboratories, Tokyo City University, 8-15-1 Todoroki, Setagaya, Tokyo 158-0082 (Japan); Nakamura, Kotaro; Toko, Kaoru [Institute of Applied Physics, University of Tsukuba, 1-1-1 Tennohdai, Tsukuba, Ibaraki 305-8573 (Japan); Suemasu, Takashi [Core Research for Evolutional Science and Technology, Japan Science and Technology Agency, Gobancho, Chiyoda, Tokyo 102-0076 (Japan); Institute of Applied Physics, University of Tsukuba, 1-1-1 Tennohdai, Tsukuba, Ibaraki 305-8573 (Japan)

    2014-04-30

    Phosphorus doping by P implantation and thermal annealing of the BaSi{sub 2} epitaxial film grown on the Si(111) substrate has been studied. Raman spectroscopy results show that the structural damage due to P implantation can be almost removed by annealing within 30 and 1 s at 500 and 700 °C, respectively. The depth profile of P is investigated by secondary ion mass spectroscopy, which reveals considerably slower diffusion kinetics of P at 500 °C than 700 °C. The activation energy of the diffusion is roughly estimated to be 2 eV from the temperature dependence. The Hall measurement of the P-doped films clarifies that the P impurity is an electron donor in BaSi{sub 2}. The average electron density up to the order of 10{sup 18} cm{sup −3} is observed. - Highlights: • P doping of BaSi{sub 2} epitaxial films by ion implantation and thermal annealing is studied. • Damage is recovered within 30 and 1 s at 500 and 700 °C, respectively. • Considerably slower P diffusion is observed at 500 °C than 700 °C. • P impurity is revealed to be an electron donor in BaSi{sub 2}. • The average electron density up to the order of 10{sup 18} cm{sup −3} is observed.

  2. Cochlear Implants

    Science.gov (United States)

    A cochlear implant is a small, complex electronic device that can help to provide a sense of sound. People who are ... of-hearing can get help from them. The implant consists of two parts. One part sits on ...

  3. Cochlear Implants

    Science.gov (United States)

    ... imaging (MRI) scans, to evaluate your inner ear anatomy. Cochlear implant surgery Cochlear implant surgery is usually performed as an outpatient procedure under general anesthesia. An incision is made behind the ear ...

  4. Effects of Plasma Nitriding on the Erosion Behavior of AISI 403 Stainless Steel Solid State Particles

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Won; Park, Hee Jin; Baik, Kyeong Ho [Chungnam National University, Daejeon (Korea, Republic of); Kim, In Soo; Yang, Byung Il [Doosan Heavy Industries and Construction Co., Ltd., Changwon (Korea, Republic of)

    2014-01-15

    This study investigated the effects of plasma nitriding on the erosion behavior of AISI 403 stainless steel solid state particles at ambient temperature and 620 ℃ using Fe{sub 3}O{sub 4} erodent particles at impact angles of 15-90°. The plasma nitriding formed a thick hardened layer which had a high microhardness of 1210 ± 15 Hv. At ambient temperature, AISI 403 suffered from severe erosion damage at low impact angles and exhibited ductile erosive behavior, while the nitrided layer experienced no significant damage at any impact angles. For AISI 403, the erosion rates at 620 ℃ were ⁓2 times higher than those obtained at ambient temperature. When eroded at 620 ℃, the nitrided layer exhibited a ductile erosive manner, with a maximum erosion rate occurring at a low impact angle of 30°. The results from high temperature hardness measurement and the observation of the eroded surface are discussed to explain the high-temperature erosion behavior of the nitrided AISI 403 stainless steel.

  5. Micro-structural strengthening mechanism of multiple laser shock processing impacts on AISI 8620 steel

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J.Z. [School of Mechanical Engineering, Jiangsu University, Xuefu Road 301, Jingkou District, Zhenjiang 212013 (China); Zhong, J.W., E-mail: zjw1033@126.com [School of Mechanical Engineering, Jiangsu University, Xuefu Road 301, Jingkou District, Zhenjiang 212013 (China); Luo, K.Y.; Zhang, L.; Dai, F.Z. [School of Mechanical Engineering, Jiangsu University, Xuefu Road 301, Jingkou District, Zhenjiang 212013 (China); Chen, K.M. [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Wang, Q.W.; Zhong, J.S.; Zhang, Y.K. [School of Mechanical Engineering, Jiangsu University, Xuefu Road 301, Jingkou District, Zhenjiang 212013 (China)

    2011-07-25

    Highlights: {yields} LSP can clearly refine coarse grains in the shocked region by dislocation movement. {yields} Micro-structural evolution of AISI 8620 steel after LSP impacts is revealed. {yields} LSP on AISI 8620 steel have grain refinement and dispersion strengthening of carbon. {yields} The results can provide some insights on surface modification of low carbon steel. - Abstract: Micro-structural evolution in the near-surface region of AISI 8620 steel subjected to multiple laser shock processing (LSP) impacts were investigated by means of cross-sectional optical microscopy (OM) and transmission electron microscopy (TEM) observations. Micro-structural evolution process subjected to multiple LSP impacts can be described as follows: (i) the parallel lamellar pearlites are broken into bitty pearlites, and dislocation activities simultaneously led to the formation of dislocation lines (DLs) and dislocation pile-ups in original grains; (ii) bitty pearlites were all broken into Fe{sub 3}C granules, and dislocation movement made Fe{sub 3}C granules disperse near subgrain boundaries and led to subgrain boundaries separating individual cells, and (iii) subgrain boundaries were refined to grain boundaries. Multiple LSP impacts on AISI 8620 steel had dual-function: the refinement of coarse grains in the near-surface region by dislocation movement and dispersion strengthening of C atoms which cut cementite and diffused into the ferrite by moving dislocations.

  6. Influence of temperature on AISI 316L corrosion in phosphoric acid solutions under hydrodynamic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Tovar, R.; Montanes, M.T.; Garcia-Anton, J. [Valencia Univ. Politecnica, Dept. de Ingenieria Quimica y Nuclear. ETSI Industriales, Valencia (Spain); Ben Bachir, A.; Abdelkebir, B.; Elmandoubi, N. [University Mohammed V-Agdal, Lab. Corrosion-Electrochimie, Faculty of Sciences, Rabat (Morocco)

    2009-07-01

    AISI 316L stainless steel, due to its good mechanical properties and corrosion resistance, is widely used in the phosphoric acid industry, including piping lines. However, phosphoric acid (H{sub 3}PO{sub 4}) is a medium-strong acid, and corrosion problems could occur, especially working with concentrated solutions and increasing temperature. Furthermore, fluid flow can increase corrosion rates. The objective of this work is to study the dynamic corrosion of AISI 316L stainless steel in a range of temperature from 25 C to 60 C by means of cyclic potentiodynamic curves. A hydrodynamic circuit was used in order to study dynamic corrosion. The experiments were carried out in an oxygen-free environment at different Reynolds numbers: 1,456, 3,166 and 5,066. The results show that uniform corrosion mechanisms can be expected for AISI 316L stainless steel in 5.5 M H{sub 3}PO{sub 4} solutions, since no hysteresis loop was observed. Moreover, temperature affects the corrosion parameters obtained from the polarization curves. Temperature shifts corrosion potential to nobler values, reduces the passivity region and enhances passivation current density. On the other hand, little influence of Reynolds number was observed on AISI 316L stainless steel corrosion. (authors)

  7. Surface characterization and wear behaviour of laser surface melted AISI 316L stainless steel

    CSIR Research Space (South Africa)

    Kumar, A

    2010-01-01

    Full Text Available The present study concerns an in depth investigation of the influence of laser surface melting of AISI 316L stainless steel using Ar and N2 as shrouding atmosphere. Laser surface melting has been carried out using a 5 kW continuous wave (CW) fibre...

  8. Pharmacological evaluation of adipose dysfunction via 11β-hydroxysteroid dehydrogenase type 1 in the development of diabetes in diet-induced obese mice with cortisone pellet implantation.

    Science.gov (United States)

    Akiyama, Nobuteru; Akiyama, Yuko; Kato, Hideaki; Kuroda, Takayuki; Ono, Takashi; Imagawa, Keiichi; Asakura, Kenji; Shinosaki, Toshihiro; Murayama, Toshihiko; Hanasaki, Kohji

    2014-04-01

    Signals from intracellular glucocorticoids (GCs) via 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) in adipose tissues have been reported to serve as amplifiers leading to deterioration of glucose metabolism associated with obesity. To elucidate adipose dysfunction via 11β-HSD1 activation in the development of obesity-related diabetes, we established novel diabetic mice by implanting a cortisone pellet (CP) in diet-induced obesity (DIO) mice. Cortisone pellet-implanted DIO mice (DIO/CP mice) showed hyperglycemia, insulin resistance, hyperlipidemia, and ectopic fat accumulation, whereas cortisone pellet implantation in lean mice did not induce hyperglycemia. In DIO/CP mice, indexes of lipolysis such as plasma glycerol and nonesterified fatty acids (NEFAs) increased before hyperglycemia appeared. Furthermore, the adipose mRNA level of 11β-HSD1 was up-regulated in DIO/CP mice compared with sham-operated DIO mice. RU486 (mifepristone, 11β-[p-(dimethylamino)phenyl]-17β-hydroxy-17-(1-propynyl)estra-4,9-dien-3-one), a glucocorticoid receptor antagonist, decreased adipose mRNA levels of 11β-HSD1 as well as adipose triglyceride lipase. RU486 also improved plasma NEFA, glycerol, and glucose levels in DIO/CP mice. These results demonstrate that lipolysis in adipose tissues caused by GC activation via 11β-HSD1 serves as a trigger for diabetes with ectopic fat accumulation. Our findings also indicate the possibility of a vicious circle of GC signals via 11β-HSD1 up-regulation in adipose tissues, contributing to deterioration of glucose metabolism to result in diabetes. Our DIO/CP mouse could be a suitable model of type 2 diabetes to evaluate adipose dysfunction via 11β-HSD1.

  9. Reversal of diabetes in mice with a bioengineered islet implant incorporating a type I collagen hydrogel and sustained release of vascular endothelial growth factor.

    Science.gov (United States)

    Vernon, Robert B; Preisinger, Anton; Gooden, Michel D; D'Amico, Leonard A; Yue, Betty B; Bollyky, Paul L; Kuhr, Christian S; Hefty, Thomas R; Nepom, Gerald T; Gebe, John A

    2012-01-01

    We have developed a bioengineered implant (BI) to evaluate strategies to promote graft survival and function in models of islet transplantation in mice. The BI, sized for implantation within a fold of intestinal mesentery, consists of a disk-shaped, polyvinyl alcohol sponge infused with a type I collagen hydrogel that contains dispersed donor islets. To promote islet vascularization, the BI incorporates a spherical alginate hydrogel for sustained release of vascular endothelial growth factor (VEGF). BIs that contained 450-500 islets from syngeneic (C57Bl/6) donors and 20 ng of VEGF reversed streptozotocin (STZ)-induced diabetes in 100% of mice (8/8), whereas BIs that contained an equivalent number of islets, but which lacked VEGF, reversed STZ-induced diabetes in only 62.5% of mice (5/8). Between these "+VEGF" and "-VEGF" groups, the time to achieve normoglycemia (8-18 days after implantation) did not differ statistically; however, transitory, postoperative hypoglycemia was markedly reduced in the +VEGF group relative to the -VEGF group. Notably, none of the mice that achieved normoglycemia in these two groups required exogenous insulin therapy once the BIs began to fully regulate levels of blood glucose. Moreover, the transplanted mice responded to glucose challenge in a near-normal manner, as compared to the responses of healthy, nondiabetic (control) mice that had not received STZ. In future studies, the BIs described here will serve as platforms to evaluate the capability of immunomodulatory compounds, delivered locally within the BI, to prevent or reverse diabetes in the setting of autoimmune (type 1) diabetes.

  10. Biomedical implantable microelectronics.

    Science.gov (United States)

    Meindl, J D

    1980-10-17

    Innovative applications of microelectronics in new biomedical implantable instruments offer a singular opportunity for advances in medical research and practice because of two salient factors: (i) beyond all other types of biomedical instruments, implants exploit fully the inherent technical advantages--complex functional capability, high reliability, lower power drain, small size and weight-of microelectronics, and (ii) implants bring microelectronics into intimate association with biological systems. The combination of these two factors enables otherwise impossible new experiments to be conducted and new paostheses developed that will improve the quality of human life.

  11. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  12. Resistência à corrosão de junta dissimilar soldada pelo processo TIG composta pelos aços inoxidáveis AISI 316L e AISI 444

    Directory of Open Access Journals (Sweden)

    Luis Henrique Guilherme

    2014-03-01

    Full Text Available O aço inoxidável AISI 444 tornou-se uma opção para substituir a liga AISI 316L devido ao seu menor custo e satisfatória resistência à corrosão. Entretanto, o uso da liga AISI 444 no feixe tubular de trocadores de calor acarreta na soldagem de uma junta dissimilar. O presente estudo teve por objetivo avaliar a resistência à corrosão da junta tubo-espelho soldada pelo processo TIG composta pelas ligas AISI 316L e AISI 444. A manufatura das amostras consistiu em replicar o projeto da junta tubo-espelho de trocadores de calor. Realizou-se em juntas soldadas ensaios de sensitização, perda de massa por imersão desde a temperatura ambiente até 90 ºC, e ensaios eletroquímicos de polarização potenciodinâmica nos eletrólitos 0,5 mol/L de HCl e 0,5 mol/L de H2SO4. Os resultados mostraram que a junta dissimilar sofreu corrosão galvânica com maior degradação na zona afetada pelo calor (ZAC do tubo AISI 444. Porém, os mecanismos de corrosão localizada (pite e intergranular demonstraram ser mais ativos para a liga AISI 316L. Conclui-se que a junta dissimilar apresentou melhor resistência à corrosão do que a junta soldada composta unicamente pela liga AISI 316L em temperaturas de até 70 ºC, conforme as condições observadas neste trabalho.

  13. Effect of heat treatment on an AISI 304 austenitic stainless steel evaluated by the ultrasonic attenuation coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Moghanizadeh, Abbas; Farzi, Abolfazl [Islamic Azad Univ., Esfarayen (Iran, Islamic Republic of). Dept. of Civil Engineering

    2016-07-01

    The properties of metals can be substantially changed by various methods, one of them is using heat treatment processes. Moreover, ultrasonic testing is the most preferred and effective, nondestructive testing technique for characterization of mechanical material properties. Austenitic stainless steel AISI 304 serves in many applications due to high strength and corrosion resistance. In certain applications, it is important to evaluate the mechanical properties of AISI 304 stainless steel. In this study, the ultrasonic method (attenuation measurement technique) is used to evaluate the hardness of AISI 304 stainless steel samples which were heat treated at different levels. Due to the heat treatment process, each sample has its specific microstructure and hardness which attenuate ultrasonic waves appropriately. The ultrasonic and hardness test show that it is possible to evaluate the hardness of AISI 304 stainless steel by ultrasonic attenuation coefficient. In addition, the relationship between ultrasonic attenuation coefficients and time of heat treatment is investigated.

  14. In vivo corrosion, tumor outcome, and microarray gene expression for two types of muscle-implanted tungsten alloys

    Energy Technology Data Exchange (ETDEWEB)

    Schuster, B.E. [U.S. Army Research Laboratory, Weapons and Materials Research Directorate, B434 Mulberry Road, Aberdeen Proving Ground, MD 21005-5609 (United States); Roszell, L.E. [U.S. Army Institute of Public Health, 5158 Blackhawk Road, Aberdeen Proving Ground, MD 21010‐5403 (United States); Murr, L.E.; Ramirez, D.A. [Department of Metallurgical and Materials Engineering, University of Texas, El Paso, TX 79968 (United States); Demaree, J.D. [U.S. Army Research Laboratory, Weapons and Materials Research Directorate, B434 Mulberry Road, Aberdeen Proving Ground, MD 21005-5609 (United States); Klotz, B.R. [Dynamic Science Inc., Aberdeen Proving Ground, MD 21005‐5609 (United States); Rosencrance, A.B.; Dennis, W.E. [U.S. Army Center for Environmental Health Research, Department of Chemistry, Ft. Detrick, MD 21702‐5010 (United States); Bao, W. [SAS Institute, Inc. SAS Campus Drive, Cary, NC 27513 (United States); Perkins, E.J. [U.S. Army Engineer Research and Development Center, 3909 Hall Ferry Road, Vicksburg MS 39180 (United States); Dillman, J.F. [U.S. Army Medical Research Institute of Chemical Defense, 3100 Ricketts Point Road, Aberdeen Proving Ground, MD 21010‐5400 (United States); Bannon, D.I., E-mail: desmond.bannon@us.army.mil [U.S. Army Institute of Public Health, 5158 Blackhawk Road, Aberdeen Proving Ground, MD 21010‐5403 (United States)

    2012-11-15

    Tungsten alloys are composed of tungsten microparticles embedded in a solid matrix of transition metals such as nickel, cobalt, or iron. To understand the toxicology of these alloys, male F344 rats were intramuscularly implanted with pellets of tungsten/nickel/cobalt, tungsten/nickel/iron, or pure tungsten, with tantalum pellets as a negative control. Between 6 and 12 months, aggressive rhabdomyosarcomas formed around tungsten/nickel/cobalt pellets, while those of tungsten/nickel/iron or pure tungsten did not cause cancers. Electron microscopy showed a progressive corrosion of the matrix phase of tungsten/nickel/cobalt pellets over 6 months, accompanied by high urinary concentrations of nickel and cobalt. In contrast, non-carcinogenic tungsten/nickel/iron pellets were minimally corroded and urinary metals were low; these pellets having developed a surface oxide layer in vivo that may have restricted the mobilization of carcinogenic nickel. Microarray analysis of tumors revealed large changes in gene expression compared with normal muscle, with biological processes involving the cell cycle significantly up‐regulated and those involved with muscle development and differentiation significantly down‐regulated. Top KEGG pathways disrupted were adherens junction, p53 signaling, and the cell cycle. Chromosomal enrichment analysis of genes showed a highly significant impact at cytoband 7q22 (chromosome 7) which included mouse double minute (MDM2) and cyclin‐dependant kinase (CDK4) as well as other genes associated with human sarcomas. In conclusion, the tumorigenic potential of implanted tungsten alloys is related to mobilization of carcinogenic metals nickel and cobalt from corroding pellets, while gene expression changes in the consequent tumors are similar to radiation induced animal sarcomas as well as sporadic human sarcomas. -- Highlights: ► Tungsten/nickel/cobalt, tungsten/nickel/iron, and pure tungsten were studied. ► Male Fischer rats implanted with

  15. Cochlear implants in genetic deafness

    Institute of Scientific and Technical Information of China (English)

    Xuezhong Liu

    2014-01-01

    Genetic defects are one of the most important etiologies of severe to profound sensorineural hearing loss and play an important role in determining cochlear implantation outcomes. While the pathogenic mutation types of a number of deafness genes have been cloned, the pathogenesis mechanisms and their relationship to the outcomes of cochlear implantation remain a hot research area. The auditory performance is considered to be affected by the etiology of hearing loss and the number of surviving spiral ganglion cells, as well as others. Current research advances in cochlear implantation for hereditary deafness, especially the relationship among clinic-types, genotypes and outcomes of cochlear implantation, will be discussed in this review.

  16. Microstructure, Strength, and Fracture Topography Relations in AISI 316L Stainless Steel, as Seen through a Fractal Approach and the Hall-Petch Law

    Directory of Open Access Journals (Sweden)

    Oswaldo Antonio Hilders

    2015-01-01

    Full Text Available The influence of the fracture surface fractal dimension DF and the fractal dimension of grain microstructure DM on the strength of AISI 316L type austenitic stainless steel through the Hall-Petch relation has been studied. The change in complexity experimented by the net of grains, as measured by DM, is translated into the respective fracture surface irregularity through DF, in such a way that the higher the grain size (lower DM values the lower the fracture surface roughness (lower values of DF and the shallower the dimples on the fractured surfaces. The material was heat-treated at 904, 1010, 1095, and 1194°C, in order to develop equiaxed grain microstructures and then fractured by tension at room temperature. The fracture surfaces were analyzed with a scanning electron microscope, DF was determined using the slit-island method, and the values of DM were taken from the literature. The relation between grain size, DM, mechanical properties, and DF, developed for AISI 316L steel, could be generalized and therefore applied to most of the common micrograined metal alloys currently used in many key engineering areas.

  17. In vivo corrosion, tumor outcome, and microarray gene expression for two types of muscle-implanted tungsten alloys.

    Science.gov (United States)

    Schuster, B E; Roszell, L E; Murr, L E; Ramirez, D A; Demaree, J D; Klotz, B R; Rosencrance, A B; Dennis, W E; Bao, W; Perkins, E J; Dillman, J F; Bannon, D I

    2012-11-15

    Tungsten alloys are composed of tungsten microparticles embedded in a solid matrix of transition metals such as nickel, cobalt, or iron. To understand the toxicology of these alloys, male F344 rats were intramuscularly implanted with pellets of tungsten/nickel/cobalt, tungsten/nickel/iron, or pure tungsten, with tantalum pellets as a negative control. Between 6 and 12 months, aggressive rhabdomyosarcomas formed around tungsten/nickel/cobalt pellets, while those of tungsten/nickel/iron or pure tungsten did not cause cancers. Electron microscopy showed a progressive corrosion of the matrix phase of tungsten/nickel/cobalt pellets over 6 months, accompanied by high urinary concentrations of nickel and cobalt. In contrast, non-carcinogenic tungsten/nickel/iron pellets were minimally corroded and urinary metals were low; these pellets having developed a surface oxide layer in vivo that may have restricted the mobilization of carcinogenic nickel. Microarray analysis of tumors revealed large changes in gene expression compared with normal muscle, with biological processes involving the cell cycle significantly up-regulated and those involved with muscle development and differentiation significantly down-regulated. Top KEGG pathways disrupted were adherens junction, p53 signaling, and the cell cycle. Chromosomal enrichment analysis of genes showed a highly significant impact at cytoband 7q22 (chromosome 7) which included mouse double minute (MDM2) and cyclin-dependant kinase (CDK4) as well as other genes associated with human sarcomas. In conclusion, the tumorigenic potential of implanted tungsten alloys is related to mobilization of carcinogenic metals nickel and cobalt from corroding pellets, while gene expression changes in the consequent tumors are similar to radiation induced animal sarcomas as well as sporadic human sarcomas.

  18. Comparison of the Electrochemical Behavior of Ti and Nanostructured Ti-Coated AISI 304 Stainless Steel in Strongly Acidic Solutions

    Science.gov (United States)

    Attarzadeh, Farid Reza; Elmkhah, Hassan; Fattah-Alhosseini, Arash

    2017-02-01

    In this study, the electrochemical behaviors of pure titanium (Ti) and nanostructured (NS) Ti-coated AISI 304 stainless steel (SS) in strongly acidic solutions of H2SO4 were investigated and compared. A type of physical vapor deposition method, cathodic arc evaporation, was applied to deposit NS Ti on 304 SS. Scanning electron microscope and X-ray diffraction were used to characterize surface coating morphology. Potentiodynamic polarization, electrochemical impedance spectroscopy, and Mott-Schottky (M-S) analysis were used to evaluate the passive behavior of the samples. Electrochemical measurements revealed that the passive behavior of NS Ti coating was better than that of pure Ti in 0.1 and 0.01 M H2SO4 solutions. M-S analysis indicated that the passive films behaved as n-type semiconductors in H2SO4 solutions and the deposition method did not affect the semiconducting type of passive films formed on the coated samples. In addition, this analysis showed that the NS Ti coating had lower donor densities. Finally, all electrochemical tests showed that the passive behavior of the Ti-coated samples was superior, mainly due to the formation of thicker, yet less defective passive films.

  19. The role of martensitic transformation on bimodal grain structure in ultrafine grained AISI 304L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Sabooni, S., E-mail: s.sabooni@ma.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, 84156-83111 Isfahan (Iran, Islamic Republic of); Karimzadeh, F.; Enayati, M.H. [Department of Materials Engineering, Isfahan University of Technology, 84156-83111 Isfahan (Iran, Islamic Republic of); Ngan, A.H.W. [Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong (China)

    2015-06-11

    In the present study, metastable AISI 304L austenitic stainless steel samples were subjected to different cold rolling reductions from 70% to 93%, followed by annealing at 700 °C for 300 min to form ultrafine grained (UFG) austenite with different grain structures. Transmission electron microscopy (TEM) and nanoindentation were used to characterize the martensitic transformation, in order to relate it to the bimodal distribution of the austenite grain size after subsequent annealing. The results showed that the martensite morphology changed from lath type in the 60% rolled sample to a mixture of lath and dislocation-cell types in the higher rolling reductions. Calculation of the Gibbs free energy change during the reversion treatment showed that the reversion mechanism is shear controlled at the annealing temperature and so the morphology of the reverted austenite is completely dependent on the morphology of the deformation induced martensite. It was found that the austenite had a bimodal grain size distribution in the 80% rolled and annealed state and this is related to the existence of different types of martensite. Increasing the rolling reduction to 93% followed by annealing caused changing of the grain structure to a monomodal like structure, which was mostly covered with small grains of around 300 nm. The existence of bimodal austenite grain size in the 80% rolled and annealed 304L stainless steel led to the improvement of ductility while maintaining a high tensile strength in comparison with the 93% rolled and annealed sample.

  20. Implantable Microimagers

    Directory of Open Access Journals (Sweden)

    Jun Ohta

    2008-05-01

    Full Text Available Implantable devices such as cardiac pacemakers, drug-delivery systems, and defibrillators have had a tremendous impact on the quality of live for many disabled people. To date, many devices have been developed for implantation into various parts of the human body. In this paper, we focus on devices implanted in the head. In particular, we describe the technologies necessary to create implantable microimagers. Design, fabrication, and implementation issues are discussed vis-à-vis two examples of implantable microimagers; the retinal prosthesis and in vivo neuro-microimager. Testing of these devices in animals verify the use of the microimagers in the implanted state. We believe that further advancement of these devices will lead to the development of a new method for medical and scientific applications.

  1. Crack propagation in stainless steel AISI 304L in Hydrogen Chemistry conditions (HWC); Propagacion de Grietas en Acero Inoxidable AISI 304L en Condiciones de Quimica de Hidrogeno (HWC)

    Energy Technology Data Exchange (ETDEWEB)

    Diaz S, A.; Fuentes C, P.; Merino C, F. [ININ, Carretera Mexico -Toluca s/n, La Marquesa, Ocoyoacac, Mexico (Mexico); Castano M, V. [Instituto de Fisica Aplicada, UNAM, Km 15.5 Carretera Queretaro-San Luis Potosi, Juriquilla, Queretaro (Mexico)]. e-mail: ads@nuclear.inin.mx

    2006-07-01

    Velocities of crack growth in samples type CT pre cracking of stainless steel AISI 304l solder and sensitized thermally its were obtained by the Rising Displacement method or of growing displacement. It was used a recirculation circuit that simulates the operation conditions of a BWR type reactor (temperature of 280 C and a pressure of 8 MPa) with the chemistry modified by the addition of hydrogen with and without the addition of impurities of a powerful oxidizer like the Cu{sup +} ion. In each essay stayed a displacement velocity was constant of 1x10{sup -9} m/s, making a continuous pursuit of the advance of the crack by the electric potential drop technique. Contrary to the idea of mitigation of the crack propagation velocity by effect of the addition of the hydrogen in the system, the values of the growth velocities obtained by this methodology went similar to the opposing ones under normal operation conditions. To the finish of the rehearsal one carries out the fractographic analysis of the propagation surfaces, which showed cracks growth in trans and intergranular way, evidencing the complexity of the regulator mechanisms of the IGSCC like in mitigation conditions as the alternative Hydrogen Chemistry. (Author)

  2. Análisis experimental del torneado de alta velocidad del acero AISI 1045 // Experimental analysis of high speed turning of AISI 1045 steel gears

    Directory of Open Access Journals (Sweden)

    Luís Wilfredo Hernández‐González

    2012-01-01

    Full Text Available El objetivo de este trabajo es el estudio experimental de la evolución del desgaste del flanco de dosinsertos de carburo recubiertos y un cermet, durante el torneado en seco del acero AISI 1045 con 500 y600 m/min de velocidad de corte. Los resultados fueron comparados utilizando el análisis de varianza y deregresión. La investigación mostró un efecto significativo de la velocidad de corte y del tiempo demaquinado en el desgaste del flanco. El mejor desempeño fue para el carburo recubierto con tres capas,mientras que a elevada velocidad de corte el carburo con dos capas sufrió el mayor desgaste, lo cual sedebe a que cuando pierde sus recubrimientos el substrato del inserto queda desprotegido y el desgastecrece rápidamente por la extremas condiciones del mecanizado por alta velocidad. Además, se planteanrecomendaciones del tiempo de maquinado de los insertos dadas las condiciones de elaboración por altavelocidad.Palabras claves: torneado de alta velocidad, desgaste del flanco, acero AISI 1045, estudio experimental.__________________________________________________________________________AbstractThis work deals with the experimental study of the flank wear evolution of two coating carbide inserts and acermet insert during the dry turning of AISI 1045 steel with 500 and 600 m/min cutting speed. The resultswere compared using the variance and regression analysis. The investigation showed a significant effectof cutting speed and machining time on the flank wear in high speed machining. The three coating layersinsert showed the best performance while the two layers insert had the worst behaviour of the cutting toolwear at high cutting speed, this is because once the coating film is peeled off, the substrate of the insertbecomes uncovered and the wear grows rapidly due to the extreme machining conditions for high speed.Besides, the machining time recommendations of inserts for the cutting conditions at high speed areexposed.Key words: high

  3. Rolling Contact Fatigue Life and Spall Propagation Characteristics of AISI M50, M50 NiL, and AISI 52100. Part 1. Experimental Results (Preprint)

    Science.gov (United States)

    2009-10-01

    factors to the L-P life model are currently used as standard practice to account for improvements in bearing material cleanliness and processing...eleven 12.7 mm diameter ABMA Grade 10 silicon nitride (Si3N4) balls, Ra finish of 6.4 nm and one piece machined silver plated AISI 4340 steel cages...piloted on both sides of the outer ring. The outer ring cage- land shoulders of the M50NiL bearings were titanium nitride (TiN) coated per aerospace

  4. Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis.

    Science.gov (United States)

    Ivanjac, Filip; Konstantinović, Vitomir S; Lazić, Vojkan; Dordević, Igor; Ihde, Stefan

    2016-03-01

    Implant stability is a principal precondition for the success of implant therapy. Extraoral implants (EO) are mainly used for anchoring of maxillofacial epithesis. However, assessment of implant stability is mostly based on principles derived from oral implants. The aim of this study was to investigate clinical stability of EO craniofacial disk implants (single, double, and triple) by resonance frequency analysis at different stages of the bone's healing. Twenty patients with orbital (11), nasal (5), and auricular (4) defects with 50 EO implants placed for epithesis anchorage were included. Implant stability was measured 3 times; after implant placement, at 3 months and at least after 6 months. A significant increase in implant stability values was noted between all of the measurements, except for triple-disk implants between third and sixth months, and screw implants between 0 and third months. Disk implants showed lower implant stability quotient (ISQ) values compared with screw implants. Triple-disk implants showed better stability compared with single and double-disk implants. Based on resonance frequency analysis values, disk implants could be safely loaded when their ISQ values are 38 (single disks), 47 (double disks), and 48 (triple disks). According to resonance frequency analysis, disk implant stability increased over time, which showed good osseointegration and increasing mineralization. Although EO screw implants showed higher ISQ values than disk implants, disk-type implants can be safely loaded even if lower values of stability are measured.

  5. Oxidation behavior of 26Cr-16Ni and AISI 309 austenitic stainless steels in air flow at 1,173 K

    Energy Technology Data Exchange (ETDEWEB)

    Pipatnukun, Peeraya; Wangyao, Panyawat; Lothongkum, Gobboon [Chulalongkorn Univ., Bangkok (Thailand). Dept. of Metallurgical Engineering

    2015-11-01

    This work investigates the isothermal oxidation behavior of as cast 26Cr-16Ni, as cold-rolled AISI 309 and as cast AISI 309 at 1,173 K in air flow rate of 40 cm{sup 3} x min{sup -1} using thermogravimetric analysis (TGA). In 33 hours, the oxidation resistance declines from high to low are as cast 26Cr-16Ni, as cold-rolled AISI 309 and as cast AISI 309, respectively. The oxidation kinetic results show that the exponential rate constant of the as cast 26Cr-16Ni, as cold-rolled AISI 309 and as cast AISI 309 are 8.79 x 10{sup -6}, 4.02 x 10{sup -5} and 4.35 x 10{sup -5} g x cm{sup -2} x s{sup -n}, respectively. The exponential growth rates of as cast 26Cr-16Ni, as cold-rolled AISI 309 and as cast AISI 309 are 0.42, 0.29 and 0.32, respectively. It indicates that the oxidation kinetic of as cast 26Cr-16Ni approaches a parabolic rate law, but those of as cold-rolled and as cast AISI 309 approach the cubic rate law. The sequence of oxide scale formations on the tested samples is also discussed.

  6. In Situ Observation of Solidification Process of AISI 304 Austenitic Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    HUANG Fu-xiang; WANG Xin-hua; ZHANG Jiong-ming; JI Chen-xi; FANG Yuan; YU Yan

    2008-01-01

    The solidification process of AISI 304 stainless steel during cooling at a rate of 0.05 K/s has been observed in situ using a confocal scanning laser microscope(CSLM).The results show that the δ phase appeared first in liquid steel,as the temperature decreased,the γ phase precipitated prior at δ-grain boundary at 1452.2℃,the liquid steel disappeared at 1431.3℃,and then theγphase precipitated on the δ ferrite.Based on the Scheil-GulliVer solidification model,the solidification processes of AISI 304 stainless steel are simulated using the Scheil model in Thermo-Calc.and the simulation results agree well with the results observed in the experiment.

  7. Characterization of the expanded austenite developed on AISI 316 LM steel by plasma nitriding

    Directory of Open Access Journals (Sweden)

    Keddam M.

    2017-01-01

    Full Text Available AISI 316 LM samples were plasma nitrided at a temperature of 380°C for different times between 0.5 and 8 h in a 85%N2- 15%H2 gas mixture. Different experimental techniques such as: optical microscopy (OM, X- ray diffraction (XRD and glow discharge optical emission spectroscopy (GDOES were used to characterize the expanded austenite layer formed at the surface of AISI 316 LM stainless steel. The microscopical observations revealed the presence of the expanded austenite with a mean layer thickness between 1.90 and 4.31 μm. The growth kinetics of expanded austenite was also investigated. In addition, both the compressive stresses in the expanded austenite layer and the compositional strains were estimated by means of a simple mechanical model based on the XRD results.

  8. Corrosion resistance of the welded AISI 316L after various surface treatments

    Directory of Open Access Journals (Sweden)

    Tatiana Liptáková

    2014-01-01

    Full Text Available The main aim of this work is to monitor the surface treatment impact on the corrosion resistance of the welded stainless steel AISI 316L to local corrosion forms. The excellent corrosion resistance of austenitic stainless steel is caused by the existence of stable, thin and well adhering passive layer which quality is strongly influenced by welding. Therefore surface treatment of stainless steel is very important with regard to its local corrosion susceptibility Surfaces of welded stainless steel were treated by various mechanical methods (grinding, garnet blasting. Surface properties were studied by SEM, corrosion resistance was evaluated after exposition tests in chlorides environment using weight and metalographic analysis. The experimental outcomes confirmed that the mechanical finishing has a significant effect on the corrosion behavior of welded stainless steel AISI 316L.

  9. Experimental study of mechanical properties of friction welded AISI 1021 steels

    Indian Academy of Sciences (India)

    Amit Handa; Vikas Chawla

    2013-12-01

    Friction welding is widely used as a mass production method in various industries. In the present study, an experimental set-up was designed in order to achieve friction welding of plastically deformed AISI 1021 steels. In this study, low alloy steel (AISI 1021) was welded under different welding parameters and afterwards the mechanical properties such as tensile strength, impact strength and hardness were experimentally determined. On the basis of the results obtained from the experimentation, the graphs were plotted. It is the strength of welded joints, which is fundamental property to the service reliability of the weldments and hence present work was undertaken to study the influence of axial pressure and rotational speed in friction welded joints. Axial pressure and rotational speed are the two major parameters which can influence the strength and hence the mechanical properties of the friction welded joints. Thus the axial pressure and rotational speed were taken as welding parameters, which reflect the mechanical properties.

  10. Finite Element Simulation and Experimental Verification of Internal Stress of Quenched AISI 4140 Cylinders

    Science.gov (United States)

    Liu, Yu; Qin, Shengwei; Hao, Qingguo; Chen, Nailu; Zuo, Xunwei; Rong, Yonghua

    2017-03-01

    The study of internal stress in quenched AISI 4140 medium carbon steel is of importance in engineering. In this work, the finite element simulation (FES) was employed to predict the distribution of internal stress in quenched AISI 4140 cylinders with two sizes of diameter based on exponent-modified (Ex-Modified) normalized function. The results indicate that the FES based on Ex-Modified normalized function proposed is better consistent with X-ray diffraction measurements of the stress distribution than FES based on normalized function proposed by Abrassart, Desalos and Leblond, respectively, which is attributed that Ex-Modified normalized function better describes transformation plasticity. Effect of temperature distribution on the phase formation, the origin of residual stress distribution and effect of transformation plasticity function on the residual stress distribution were further discussed.

  11. Evaluation of structural behaviour and corrosion resistant of austenitic AISI 304 and duplex AISI 2304 stainless steel reinforcements embedded in ordinary Portland cement mortars; Evaluacion del comportamiento estructural y de resistencia a la corrosion de armaduras de acero inoxidable austenitico AISI 304 y duplex AISI 2304 embebidas en morteros de cemento Portland

    Energy Technology Data Exchange (ETDEWEB)

    Medina, E.; Cobo, A.; Bastidas, D. M.

    2012-07-01

    The mechanical and structural behaviour of two stainless steels reinforcements, with grades austenitic EN 1.4301 (AISI 304) and duplex EN 1.4362 (AISI 2304) have been studied, and compared with the conventional carbon steel B500SD rebar. The study was conducted at three levels: at rebar level, at section level and at structural element level. The different mechanical properties of stainless steel directly influence the behaviour at section level and structural element level. The study of the corrosion behaviour of the two stainless steels has been performed by electrochemical measurements, monitoring the corrosion potential and the lineal polarization resistance (LPR), of reinforcements embedded in ordinary Portland cement (OPC) mortar specimens contaminated with different amount of chloride over one year time exposure. Both stainless steels specimens embedded in OPC mortar remain in the passive state for all the chloride concentration range studied after one year exposure. (Author) 26 refs.

  12. Finite Element Simulation and Experimental Verification of Internal Stress of Quenched AISI 4140 Cylinders

    Science.gov (United States)

    Liu, Yu; Qin, Shengwei; Hao, Qingguo; Chen, Nailu; Zuo, Xunwei; Rong, Yonghua

    2017-01-01

    The study of internal stress in quenched AISI 4140 medium carbon steel is of importance in engineering. In this work, the finite element simulation (FES) was employed to predict the distribution of internal stress in quenched AISI 4140 cylinders with two sizes of diameter based on exponent-modified (Ex-Modified) normalized function. The results indicate that the FES based on Ex-Modified normalized function proposed is better consistent with X-ray diffraction measurements of the stress distribution than FES based on normalized function proposed by Abrassart, Desalos and Leblond, respectively, which is attributed that Ex-Modified normalized function better describes transformation plasticity. Effect of temperature distribution on the phase formation, the origin of residual stress distribution and effect of transformation plasticity function on the residual stress distribution were further discussed.

  13. Sub-surface Fatigue Crack Growth at Alumina Inclusions in AISI 52100 Roller Bearings

    DEFF Research Database (Denmark)

    Cerullo, Michele

    2014-01-01

    Sub-surface fatigue crack growth at non metallic inclusions is studied in AISI 52100 bearing steel under typical rolling contact loads. A first 2D plane strain finite element analysis is carried out to compute the stress history in the innner race at a characteristic depth, where the Dang Van...... damage factor is highest. Subsequently the stress history is imposed as boundary conditions in a periodic unit cell model, where an alumina inclusion is embedded in a AISI 52100 matrix. Cracks are assumed to grow radially from the inclusion under cyclic loading. The growth is predicted by means...... of irreversible fatigue cohesive elements. Different orientations of the cracks and different matrix-inclusion bonding conditions are analyzed and compared....

  14. Boriding kinetics of Fe2B layers formed on AISI 1045 steel

    Directory of Open Access Journals (Sweden)

    Zuno-Silva J.

    2014-01-01

    Full Text Available In the present work, a diffusion model was suggested to study the growth kinetics of Fe2B layers grown on the AISI 1045 steel by the pack-boriding treatment. The generated boride layers were analyzed by optical microscopy and X-ray diffraction analysis. The applied diffusion model is based on the principle of mass conservation at the (Fe2B/ substrate interface. It was used to estimate the boron diffusion coefficients of Fe2B in the temperature range of 1123-1273 K. A validation of the model was also made by comparing the experimental Fe2B layer thickness obtained at 1253 K for 5 h of treatment with the predicted value. Basing on our experimental results, the boron activation energy was estimated as 180 kJ mol-1 for the AISI 1045 steel.

  15. Study of carbonitriding thermochemical treatment by plasma screen in active with pressures main austenitic stainless steels AISI 409 and AISI 316L; Estudo do tratamento termoquimico de carbonitretacao por plasma em tela ativa com pressoes variaveis nos acos inoxidaveis austenitico AISI 316L e ferririco AISI 409

    Energy Technology Data Exchange (ETDEWEB)

    Melo, M.S.; Oliveira, A.M.; Leal, V.S.; Sousa, R.R.M. de; Alves Junior, C. [Centro Federal de Educacao Tecnologica do Maranhao (CEFET/MA), Sao Luis, MA (Brazil); Centro Federal de Educacao Tecnologica do Piaui (CEFET/PI), Teresina, PI (Brazil); Universidade Federal do Rio Grande do Norte (DF/UFRN), Natal, RN (Brazil). Dept. de Fisica. Labplasma

    2010-07-01

    The technique called Active Screen Plasma Nitriding (ASPN) is being used as an alternative once it offers several advantages with respect to conventional DC plasma. In this method, the plasma does not form directly in the sample's surface but on a screen, in such a way that undesired effects such as the edge effect is minimized. Stainless steels present not very satisfactory wearing characteristics. However, plasma carbonitriding has been used as to improve its resistance to wearing due to the formation of a fine surface layer with good properties. In this work, samples of stainless steel AISI 316L and AISI 409 were treated at pressures of 2.5 and 5 mbar. After the treatments they were characterized by microhardness, microscopy and Xray diffraction. Microscopy and hardness analysis showed satisfactory layers and toughness in those steels. (author)

  16. Processing of microCT implant-bone systems images using Fuzzy Mathematical Morphology

    Science.gov (United States)

    Bouchet, A.; Colabella, L.; Omar, S.; Ballarre, J.; Pastore, J.

    2016-04-01

    The relationship between a metallic implant and the existing bone in a surgical permanent prosthesis is of great importance since the fixation and osseointegration of the system leads to the failure or success of the surgery. Micro Computed Tomography is a technique that helps to visualize the structure of the bone. In this study, the microCT is used to analyze implant-bone systems images. However, one of the problems presented in the reconstruction of these images is the effect of the iron based implants, with a halo or fluorescence scattering distorting the micro CT image and leading to bad 3D reconstructions. In this work we introduce an automatic method for eliminate the effect of AISI 316L iron materials in the implant-bone system based on the application of Compensatory Fuzzy Mathematical Morphology for future investigate about the structural and mechanical properties of bone and cancellous materials.

  17. Electrochemical study of AISI 304 stainless steel during the exposure at the disinfectant solutions with fungal suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Stoica, M.; Bruma, M. [Department of Biochemistry and Technologies, Faculty of Food Science and Engineering, ' ' Dunarea de Jos' ' University of Galati, 111 Domneasca Street, 800201 Galati (Romania); Carac, G. [Department of Chemistry, Faculty of Sciences, ' ' Dunarea de Jos' ' University of Galati, 47 Domneasca Street, 800008 Galati (Romania)

    2010-12-15

    The effect of fungal suspensions on the disinfectant solution (Actisept with sodium dichloroisocyanurate as active substance, which releases 140 ppm active chlorine) and the corrosion behavior of type AISI 304 stainless steel (SS) were evaluated through linear polarization. The work presents a study of biocide Actisept solution as reference solution and the mixed solutions: reference biocide Actisept solution with three fungal suspensions (10 vol%), Aspergillus niger, Candida mycoderma, and Saccharomyces cerevisiae. The fungal suspension has an important influence on the synergistic effect of the SS corrosion in the following order: Saccharomyces cerevisiae > Candida mycoderma > Aspergillus niger. The E{sub corr} values from the mixed solutions decreased with immersion time of the samples. In the case of Aspergillus niger, the corrosion rate was lower than that of any other type of fungal suspension tested, because the arrangement in solutions, the size and composition of Aspergillus niger spores were more favorable to protect the spores of the chemical and the electrical stressing. The results showed that there is a synergistic effect between the active substances from the disinfectant, fungal suspensions and applied potential, thus this effect can be taken into consideration for the hygienic and safety food industry. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Estimation of Mechanical Properties of Stainless Steel AISI 410 by Small-Punch Testing (Erickson Test)

    Science.gov (United States)

    Hassan, A.-P.

    2014-07-01

    The small-punch testing (SPT) method is used for determining the mechanical properties of AISI 410 (0.14% C, 12% Cr) stainless steel. A thin disc-shaped specimen with known mechanical properties is pressed with a small ball until the appearance of cracks in the former. The load - displacement curves are recorded. Computation of the yield strength and fracture energy by the curve obtained and by known formulas shows good convergence with the characteristics obtained by standard testing.

  19. Friction welding of AA6061 to AISI 4340 using silver interlayer

    OpenAIRE

    Suresh D. Meshram; G. Madhusudhan Reddy

    2015-01-01

    The present work pertains to the study on joining of AA6061 and AISI 4340 through continuous drive friction welding. The welds were evaluated by metallographic examination, X-ray diffraction, electron probe microanalysis, tensile test and microhardness. The study reveals that the presence of an intermetallic compound layer at the bonded interface exhibits poor tensile strength and elongation. Mg in AA6061 near to the interface is found to be favourable for the formation and growth of Fe2Al5 i...

  20. Cathodic cage nitriding of AISI 409 ferritic stainless steel with the addition of CH4

    Directory of Open Access Journals (Sweden)

    Rômulo Ribeiro Magalhães de Sousa

    2012-04-01

    Full Text Available AISI 409 ferritic stainless steel samples were nitrided using the cathodic cage plasma nitriding technique (CCPN, with the addition of methane to reduce chromium precipitation, increase hardness and wear resistance and reduce the presence of nitrides when compared to plasma carbonitriding. Microhardness profiles and X-Ray analysis confirm the formation of a very hard layer containing mainly ε-Fe3N and expanded ferrite phases.

  1. Welding of AA1050 aluminum with AISI 304 stainless steel by rotary friction welding process

    OpenAIRE

    Chen Ying An; Francisco Piorino Neto; Eder Paduan Alves

    2010-01-01

    The purpose of this work was to assess the development of solid state joints of dissimilar material AA1050 aluminum and AISI 304 stainless steel, which can be used in pipes of tanks of liquid propellants and other components of the Satellite Launch Vehicle. The joints were obtained by rotary friction welding process (RFW), which combines the heat generated from friction between two surfaces and plastic deformation. Tests were conducted with different welding process parameters. The results we...

  2. Martensitic transformation during fatigue testing of an AISI 301LN steel

    OpenAIRE

    Mateo García, Antonio Manuel; Fargas Ribas, Gemma

    2012-01-01

    The plastic deformation accumulated during fatigue testing can induce the transformation of austenite to martensite in metastable austenitic stainless steels. To analyze this issue, a metastable austenitic stainless steel grade AISI 301 LN was studied in two different conditions, i.e. annealed and cold rolled. In the first case, the steel was fully austenitic, whereas cold rolled material had almost 30% of martensite. High cycle fatigue tests at a stress ratio of 0.8 were carried out on flat ...

  3. Martensitic Transformation in Ultrafine-Grained Stainless Steel AISI 304L Under Monotonic and Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Heinz Werner Höppel

    2012-02-01

    Full Text Available The monotonic and cyclic deformation behavior of ultrafine-grained metastable austenitic steel AISI 304L, produced by severe plastic deformation, was investigated. Under monotonic loading, the martensitic phase transformation in the ultrafine-grained state is strongly favored. Under cyclic loading, the martensitic transformation behavior is similar to the coarse-grained condition, but the cyclic stress response is three times larger for the ultrafine-grained condition.

  4. Analise de falhas em implantes cirúrgicos

    OpenAIRE

    Abud, Ibrahim de Cerqueira; Souza, Sônia Maria Coelho de; Oliveira,Marize Varella

    2011-01-01

    São apresentados casos de falha em implantes cirúrgicos fabricados em aço inoxidável AISI 316L utilizados para redução de fratura de fêmur. As técnicas empregadas na análise dos problemas foram: inspeção visual, análise química, análise metalográfica e microscopia eletrônica de varredura. As falhas dos implantes importados estavam relacionadas a fatores alheios à qualidade do material fora de especificação sob ponto de vista químico e metalúrgico. Constatou-se a necessidade de ações relativa...

  5. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Lemos, Pedro A; van Vooren, Priya R;

    2004-01-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative emoti...

  6. MICROSTRUCTURE AND CORROSION RESISTANCE OF CHROMIUM NITRIDES OBTAINED BY VACUUM GAS NITRIDING OF ELECTROLYTIC CHROMIUM DEPOSITED ON AISI H13 STEEL

    Directory of Open Access Journals (Sweden)

    H. Cifuentes

    2013-06-01

    Full Text Available In this scientific research paper, the microstructure and corrosion resistance of chromium nitrides obtained from a duplex treatment consisting of an electroplated hard chromium coating applied on a steel AISI H13 follow by a thermochemical treatment in vacuum using NH3 as precursor gas of nitrogen, is evaluated. This type of duplex treatments combine the benefits of each individual treatment in order to obtain, with this synergic effect, compounds type CrxN more economic than those obtained by other kind of treatments e.g. physical vapor deposition (PVD. The results obtained by X-Ray Diffraction (XRD indicate the surface and subsurface transformation of the electrolytic hard chromium coating by formation of CrN and Cr2N phases. Likewise, potentiodynamic polarization tests indicate an increase in corrosion resistance of such kind of compounds in comparison with the obtained results with electroplated hard chromium.

  7. Wear resistance of Fe-Nb-Cr-W, Nb, AISI 1020 and AISI 420 coatings produced by thermal spray wire arc; Resistencia al desgaste de recubrimientos Fe-Nb-Cr-W, Nb, AISI 1020 y AISI 420 producidos por proyeccion termica por arco electrico

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Covaleda, E. A.; Mercado-Veladia, J. L.; Olaya-Florez, J. J.

    2013-07-01

    The commercial materials 140MXC (with iron, tungsten, chrome, niobium), 530AS (AISI 1015 steel) and 560AS (AISI 420 steel) on AISI 4340 steel were deposited using thermal spray with arc. The aim of work was to evaluate the best strategy abrasive wear resistance of the system coating-substrate using the following combinations: (1) homogeneous coatings and (2) coatings depositing simultaneously 140MXC + 530AS and 140MXC + 560AS. The coatings microstructure was characterized using Optical microscopy, Scanning electron microscopy and Laser con focal microscopy. The wear resistance was evaluated through dry sand rubber wheel test (DSRW). We found that the wear resistance depends on the quantity of defects and the mechanical properties like hardness. For example, the softer coatings have the biggest wear rates and the failure mode was characterized by plastic deformation caused by particles indentation, and the other hand the failure mode at the harder materials was grooving. The details and wear mechanism of the coatings produced are described in this investigation. (Author)

  8. Influence of the surface finishing on electrochemical corrosion characteristics of AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Sylvia Dundeková

    2015-05-01

    Full Text Available Stainless steels from 316 group are very often and successfully uses for medical applications where the good mechanical and chemical properties in combination with non-toxicity of the material assure its safe and long term usage. Corrosion properties of AISI 361L stainless steel are strongly influenced by surface roughness and treatment of the engineering parts (specimens and testing temperature. Electrochemical characteristics of ground, mechanically polished and passivated AISI 316L stainless steel specimens were examined with the aim to identify the polarization resistance evolution due to the surface roughness decrease. Results obtained on mechanically prepared specimens where only natural oxide layer created due to the exposure of the material to the corrosion environment was protecting the materials were compared to the passivated specimens with artificial oxide layer. Also the influence of temperature and stabilization time before measurement were taken into account when discussing the obtained results. Positive influence of decreasing surface roughness was obtained as well as increase of polarization resistance due to the chemical passivation of the surface. Increase of the testing temperature and short stabilization time of the specimen in the corrosion environment were observed negatively influencing corrosion resistance of AISI 316L stainless steel.

  9. Experimental investigation of wear characteristics on TiCN-coated AISI 410 steel

    Science.gov (United States)

    Prabakaran, Vijayasarathi; Sivakumaran, Ilaiyavel; Palimar, Suresh Prabhu

    2016-04-01

    In this work, the dry sliding wear test of uncoated and multilayer TiCN-coated AISI 410 steel against high carbon steel disc recognized at 2.30267 ms-1 sliding speeds and under a three series load of 5, 10 and 20 N at room temperature. On account of the more coherent interface between TiCN and C probably found, there are high hardness and superior wear resistance. Compared to AISI 410 uncoated steel, the presence of C in the multilayer TiCN coatings leads to reduced coefficient of friction and wear loss. The multilayer TiCN coating is characterized by X-ray diffraction analysis, scanning electron microscopy, micro-hardness and pin-on-disc tribometer tests. The more grooving region, pits and ploughing ridge were examined on the worn surface of the AISI 410 uncoated steel. The result shows hard multilayer TiCN-coated particles viewing on the worn surface of the high carbon steel disc.

  10. Efecto del silicio como posible elemento reactivo en la protección frente a la oxidación a elevada temperatura del acero inoxidable AISI 304

    Directory of Open Access Journals (Sweden)

    Otero, E.

    1998-05-01

    Full Text Available The influence of silicon incorporated into the alloy by means of ion implantation of 1 x 1015 ions/cm2 at 150 keV on the protective scale development based upon Cr1,3Fe0,7O3 and manganese-enriched spinels, Mn1,5Cr1,5O4 after oxidation of an austenitic AISI 304 stainless steel at 1,173 K and atmospheric pressure of air for 144 h has been studied. The presence of small quantities of silicon at the outermost layers of the alloy promotes transport of chromium during the early stages of oxidation. Further, ion implantation seems to play a beneficial role against decarburization of the alloy.

    Se estudia la influencia de silicio incorporado a la aleación mediante implantación iónica de 1 x 1015 iones/cm2 a 150 keV en el crecimiento de la capa protectora de oxidación basada en Cr1,3Fe0,7O3 y en espinelas enriquecidas en manganeso, Mn1,5Cr1,5O4, tras someter a un acero inoxidable austenítico AISI 304 a oxidación a 1.173 K y presión atmosférica de aire durante 144 h. La presencia de pequeñas cantidades de silicio en las capas más externas del material promueve el transporte de cromo durante los primeros estadios de la oxidación. Además, la implantación iónica parece ejercer un efecto beneficioso contra la descarburación de la aleación.

  11. On the characteristics of ion implanted metallic surfaces inducing dropwise condensation of steam.

    Science.gov (United States)

    Rausch, Michael H; Leipertz, Alfred; Fröba, Andreas P

    2010-04-20

    The present work provides new information on the characteristics of ion implanted metallic surfaces responsible for the adjustment of stable dropwise condensation (DWC) of steam. The results are based on condensation experiments and surface analyses via contact angle (CA) and surface free energy (SFE) measurements as well as scanning electron microscopy (SEM). For studying possible influences of the base material and the implanted ion species, commercially pure titanium grade 1, aluminum alloy Al 6951, and stainless steel AISI 321 were treated with N(+), C(+), O(+), or Ar(+) using ion beam implantation technology. The studies suggest that chemically inhomogeneous surfaces are instrumental in inducing DWC. As this inhomogeneity is apparently caused by particulate precipitates bonded to the metal surface, the resulting nanoscale surface roughness may also influence the condensation form. On such surfaces nucleation mechanisms seem to be capable of maintaining DWC even when CA and SFE measurements indicate increased wettability. The precipitates are probably formed due to the supersaturation of ion implanted metal surfaces with doping elements. For high-alloyed materials like AISI 321 or Hastelloy C-276, oxidation stimulated by the condensation process obviously tends to produce similar surfaces suitable for DWC.

  12. Propagation of crevices in stainless steel AISI304L in conditions of hydrogen chemistry (HWC); Propagacion de grietas en acero inoxidable AISI304L en condiciones de quimica de hidrogeno (HWC)

    Energy Technology Data Exchange (ETDEWEB)

    Diaz S, A.; Fuentes C, P.; Merino C, F. [ININ, 52750 Ocoyoacac, Estado de Mexico (Mexico); Castano M, V. [IFA-UNAM, Juriquilla, Queretaro (Mexico)]. e-mail: ads@nuclear.inin.mx

    2006-07-01

    Crevice growth velocities in samples of AISI 304L stainless steel thermally welded and sensitized were obtained by the Rising displacement method or of growing displacement. It was used a recirculation circuit in where the operation conditions of a BWR type reactor were simulated (temperature of 288 C and a pressure of 8 MPa) with the chemistry modified by the addition of hydrogen with and without the addition of impurities of a powerful oxidizer like the Cu{sup ++} ion. CT pre cracked specimens were used and each rehearsal stayed to one constant displacement velocity of 1 x 10{sup -9} m/s (3.6 {mu}m/hr), making a continuous pursuit of the advance of the crack by the electric potential drop technique. To the end of the rehearsal it was carried out the fractographic analysis of the propagation surfaces. The values of the growth velocities obtained by this methodology went similar to the opposing ones under normal conditions of operation; while the fractographic analysis show the cracks propagation in trans and intergranular ways, evidencing the complexity of the regulator mechanisms of the one IGSCC even under controlled ambient conditions or with mitigation methodologies like the alternative hydrogen chemistry. (Author)

  13. Influence of the density of the microwave plasma in the nitridation of the AISI 4140 steel; Influencia de la densidad del plasma de microondas en la nitruracion de acero AISI 4140

    Energy Technology Data Exchange (ETDEWEB)

    Chirino O, S.; Camps C, E.; Escobar A, L.; Mejia H, J.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2004-07-01

    A source of microwaves plasma type ECR was used to modify those mechanical properties of the surface of steel pieces AISI 4140. The experiments were carried out in a range of pressure among 4 X 10{sup -4} and 7 X 10{sup -4} Torr using one mixture of gases 60/40 hydrogen / nitrogen and an incident power of the microwaves of 400 W. Previous to the treatment of the samples, the plasma was studied using one Langmuir probe to determine the temperature of the electrons and the density of the plasma, the species excited in the plasma were determined by means of Optical emission spectroscopy. All the samples were treated during 50 min in a regime of low temperature (- 250 C), and the surface hardness it was increased up of 100% of their initial value, with a depth of penetration of the nitrogen of 4.5 {mu} m. The biggest hardness and depth of penetration of the nitrogen were obtained when the biggest density in the plasma was used to carry out the experiments. (Author)

  14. Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek).

    Science.gov (United States)

    Zeh, Alexander; Planert, Michael; Siegert, Gabriele; Lattke, Peter; Held, Andreas; Hein, Werner

    2007-02-01

    Cross-sectional study of 10 patients to measure the serum levels of cobalt and chromium after TDA. To investigate the release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc. In total hip endoprosthetics and consequently for TDA (total disc arthroplasty), metal-on-metal combinations are used with the aim of reducing wear debris. In metal-on-metal TDA the release of metal ions has until now been secondary to the main discussion. We investigated the serum cobalt and chromium concentration following implantation of 15 Maverick TDAs (monosegmental L5-S1, n = 5; bisegmental L4-L5 and L5-S1, n = 5; average age, 36.5 years). Five healthy subjects (no metal implants) acted as a control group. The measurements of the metals were carried out using the HITACHI Z-8200 AAS polarized Zeeman atomic absorption spectrometer after an average of 14.8 months. The concentrations of cobalt and chromium ions in the serum amounted on average to 4.75 microg/L (SD, 2.71) for cobalt and 1.10 microg/L (SD, 1.24) for chromium. Compared with control group, both the chromium and cobalt levels in the serum showed significant increases (Mann-Whitney U test, P = 0.0120). At follow-up,the Oswestry Disability Score was on average significantly decreased by 24.4 points (L5-S1) (t test, P < 0.05) and by 26.8 points (L4-S1) (t test, P < 0.05). The improved clinical situation is also represented by a significant decrease of the Visual Analog Pain Scale of 42.2 points after the follow-up (t test, P < 0.05). Significant systemic release of Cr/Co was proven in the serum compared with the control group. The concentrations of Cr/Co measured in the serum are similar in terms of their level to the values measured in THA metal-on-metal combinations or exceed these values given in the literature. Long-term implication of this metal exposure is unknown and should be studied further.

  15. Microstructure and antibacterial property of stainless steel implanted by Cu ions

    Institute of Scientific and Technical Information of China (English)

    XU Bo-fan; NI Hong-wei; XIONG Ping-yuan; XIONG Juan; DAN Zhi-gang

    2004-01-01

    Copper ions were implanted into AISI 304 austenitic stainless steel by metal vapor vacuum are (MEVVA) with 60 - 100 keV energy and a dose range (0.2 - 5.0) × 1017 cm-2. Then Cu-implanted stainless steel was treated by a special antibacterial treatment. Antibacterial rates of Cu-implanted stainless steel, Cu-implanted stainless steel with special antibacterial treatment and un-implanted stainless steel were obtained by agar plate method. Phase composition in the implanted layer was analyzed by glancing X-ray diffraction (GXRD). Microstructure of antibacterial stainless steel was observed with transmission electron microscopy (TEM), and changes of the bacterium appearance after 24 h antibacterial action on the surface of un-implanted and Cu-implanted stainless steel with antibacterial treatment were observed with bio-TEM respectively. The results show that stainless steel obtains antibacterial property against E. coli when the Cu ions dose approaches to the saturated one. A suitable amount of Cu-rich phase uniformly disperses on the surface of Cu-implanted stainless steel that is treated by the special antibacterial treatment. The Cu-rich phase naked on the surface has a function of damage to pericellular membrane and cell wall,the pericellular membrane is thickened and the karyon degraded, and finally, bacteria die. Cu-rich phase naked on the surface endows stainless steel with best antibacterial property.

  16. Goserelin Implant

    Science.gov (United States)

    ... in men (blockage that causes difficulty urinating), or heart or liver disease.tell your doctor if you are pregnant or plan to become pregnant. Goserelin implant should not be used in pregnant women, except ...

  17. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  18. Micromotion of Dental Implants: Basic Mechanical Considerations

    Directory of Open Access Journals (Sweden)

    Werner Winter

    2013-01-01

    Full Text Available Micromotion of dental implants may interfere with the process of osseointegration. Using three different types of virtual biomechanical models, varying contact types between implant and bone were simulated, and implant deformation, bone deformation, and stress at the implant-bone interface were recorded under an axial load of 200 N, which reflects a common biting force. Without friction between implant and bone, a symmetric loading situation of the bone with maximum loading and displacement at the apex of the implant was recorded. The addition of threads led to a decrease in loading and displacement at the apical part, but loading and displacement were also observed at the vertical walls of the implants. Introducing friction between implant and bone decreased global displacement. In a force fit situation, load transfer predominantly occurred in the cervical area of the implant. For freshly inserted implants, micromotion was constant along the vertical walls of the implant, whereas, for osseointegrated implants, the distribution of micromotion depended on the location. In the cervical aspect some minor micromotion in the range of 0.75 μm could be found, while at the most apical part almost no relative displacement between implant and bone occurred.

  19. Evaluation of performance of AISI 444 steel for application in distillation towers; Avaliacao do desempenho do aco AISI 444 para aplicacao como 'lining' em torres de destilacao

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, R.F.; Miranda, H.C. de; Farias, J.P. [Universidade Federal do Ceara (DEMM/UFC), Fortaleza, CE (Brazil). Dept. de Engenharia Metalurgica e de Materiais. Lab. de Caracterizacao de Materiais], e-mail: rf.guimaraes@yahoo.com.br

    2008-07-01

    In this work, the behavior of the AISI 444 ferritic stainless steel submitted to thermal fatigue test and their corrosion resistance in heavy crude oil was evaluated. The AWS E309MoL-16 and E316L-17 weld metal was employed as filler metal. Plates of the AISI 444 were welded on ASTM A-516 Gr. 60 plates and submitted to fatigue thermal cycle. Samples were extracted from plates welded and heat treated immersed in heavy crude oil at 300 deg C. Optical microscopy (OM), scanning electron microscopy (SEM) and energy dispersive of X-ray analysis (EDX) were used to characterize the microstructure and the corroded surface. The results show that the AISI 444 stainless steels did not present cracks after the thermal fatigue cycle and the heat treated immerse in heavy crude oil. The electrode AWS E309MoL-16 show better corrosion resistance than the AWS E316L-17. (author)

  20. Contraceptive implants.

    Science.gov (United States)

    McDonald-Mosley, Raegan; Burke, Anne E

    2010-03-01

    Implantable contraception has been extensively used worldwide. Implants are one of the most effective and reversible methods of contraception available. These devices may be particularly appropriate for certain populations of women, including women who cannot use estrogen-containing contraception. Implants are safe for use by women with many chronic medical problems. The newest implant, Implanon (Organon International, Oss, The Netherlands), is the only device currently available in the United States and was approved in 2006. It is registered for 3 years of pregnancy prevention. Contraceptive implants have failure rates similar to tubal ligation, and yet they are readily reversible with a return to fertility within days of removal. Moreover, these contraceptive devices can be safely placed in the immediate postpartum period, ensuring good contraceptive coverage for women who may be at risk for an unintended pregnancy. Irregular bleeding is a common side effect for all progestin-only contraceptive implants. Preinsertion counseling should address possible side effects, and treatment may be offered to women who experience prolonged or frequent bleeding. Thieme Medical Publishers.

  1. Estudio de los tipos de cráteres obtenidos en el impacto de proyectiles 5,56 SS109, sobre blancos de acero AISI-SAE 1045

    Directory of Open Access Journals (Sweden)

    Castro, Álvaro

    2000-02-01

    Full Text Available The present work describes the morphology and formation of the types of craters obtained with the impact of projectiles 5,56 SS109 over seven steel plates AISI-SAE 1045 that received different cycles of heat treatment. A comparison between the type of deformation and fracture structures and the ones generated by the impact of this projectile over one steel armor plate was made. Each one of the craters was characterized by visual and metallography observation. The influence of the plate microstructure on the efficiency for stopping the projectile and the mechanism of craters formation was evaluated.

    En el presente trabajo se describe la morfología y formación de los tipos de cráteres obtenidos, en el impacto de proyectiles 5,56 SS109, sobre siete chapas de acero AISI-SAE 1045 que fueron sometidas a diferentes tratamientos térmicos, comparando el tipo de estructuras de deformación y fractura obtenidas con las formadas por el impacto de uno de estos proyectiles sobre una chapa comercial para blindaje. Cada uno de los cráteres se caracterizó mediante ensayos de inspección visual y metalografía evaluándose, a partir de los resultados, el papel que ejerce la microestructura obtenida sobre el nivel de eficiencia en la detención del proyectil por parte de la chapa y el mecanismo de formación de los cráteres.

  2. Particle migration and gap healing around trabecular metal implants

    DEFF Research Database (Denmark)

    Rahbek, O; Kold, S; Zippor, B;

    2005-01-01

    Bone on-growth and peri-implant migration of polyethylene particles were studied in an experimental setting using trabecular metal and solid metal implants. Cylindrical implants of trabecular tantalum metal and solid titanium alloy implants with a glass bead blasted surface were inserted either...... in an exact surgical fit or with a peri-implant gap into a canine knee joint. We used a randomised paired design. Polyethylene particles were injected into the knee joint. In both types of surgical fit we found that the trabecular metal implants had superior bone ongrowth in comparison with solid metal...... implants (exact fit: 23% vs. 7% [p=0.02], peri-implant gap: 13% vs. 0% [p=0.02]. The number of peri-implant polyethylene particles was significantly reduced around the trabecular metal implants with a peri-implant gap compared with solid implants....

  3. Wear Evaluation of AISI 4140 Alloy Steel with WC/C Lamellar Coatings Sliding Against EN 8 Using Taguchi Method

    Science.gov (United States)

    Kadam, Nikhil Rajendra; Karthikeyan, Ganesarethinam

    2016-10-01

    The purpose of the experiments in this paper is to use the Taguchi methods to investigate the wear of WC/C coated nitrided AISI 4140 alloy steel. A study of lamellar WC/C coating which were deposited by a physical vapor deposition on nitrided AISI 4140 alloy steel. The investigation includes wear evaluation using Pin-on-disk configuration. When WC/C coated AISI 4140 alloy steel slides against EN 8 steel, it was found that carbon-rich coatings show much lower wear of the countersurface than nitrogen-rich coatings. The results were correlated with the properties determined from tribological and mechanical characterization, therefore by probably selecting the proper processing parameters the deposition of WC/C coating results in decreasing the wear rate of the substrate which shows a potential for tribological application.

  4. Preparation of high-performance ultrafine-grained AISI 304L stainless steel under high temperature and pressure

    Directory of Open Access Journals (Sweden)

    Peng Wang

    2016-08-01

    Full Text Available Bulk ultra-fine grained (UFG AISI 304L stainless steel with excellent mechanical properties was prepared by a high-temperature and high-pressure (HTHP method using nanocrystalline AISI 304L stainless steel powders obtained from ball milling. Samples were sintered in high-pressure conditions using the highest martensite content of AISI 304L stainless steel powders milled for 25 h. Analyses of phase composition and grain size were accomplished by X-ray diffraction and Rietveld refinement. By comparing the reverse martensite transformation under vacuum and HTHP treat, we consider that pressure can effectively promote the change in the process of transformation. Compared with the solid-solution-treated 304L, the hardness and yield strength of the samples sintered under HTHP are considerably higher. This method of preparation of UFG bulk stainless steel may be widely popularised and used to obtain UFG metallic materials with good comprehensive performance.

  5. Corrosion Inhibition of AISI 316L and Modified-AISI 630 Stainless Steel by the New Organic Inhibitor [(CH32N]3PSe in Chloride Media:Electrochemical and Physical Study

    Directory of Open Access Journals (Sweden)

    Yafa ZARGOUNI

    2015-04-01

    Full Text Available We evaluate the effect of the Tris-dimethylaminoselenophosphoramide (SeAPon the corrosion inhibition of modified-AISI 630 and AISI 316L stainless steel (SS in 3 wt. % NaCl. The electrochemical behaviors of tested SS samples are investigated before and after adding the Seep into the chloride media by potentiodynamic polarization technique. The adsorption of SeAP onto both SS surfaces is verified by global discharge optical emission spectroscopy (GDOES.  SeAP is found to be a good inhibitor for SS corrosion, especially when added at a concentration of 0.5 wt. %.

  6. Carburizing plasma in a low temperature austenitic stainless steel AISI 304; Cementacao a plasma em baixa temperatura de um aco inoxidavel austenitico AISI 304

    Energy Technology Data Exchange (ETDEWEB)

    Mota, W.T.; Ramos, F.D.; Rocha, R.C.; Barcelos, M.V.; Barcelos, M.A., E-mail: welber.tmota@gmail.com [Instituto Federal do Espirito Santo (IFES), ES (Brazil)

    2014-07-01

    The industrial use of thermochemical treatment assisted by the cold plasma has been widely employed in recent years, mainly oriented to the excellent results obtained in the surface modification of engineering materials, when compared to more traditional methods. In this work, we studied the plasma carburizing low temperature steel AISI 304 mechanical parts used in construction. The thermochemical treatment was performed at a fixed gas atmosphere 7% CH{sub 4} (g) and 93 % H{sub 2} (g), 350 ° C and times of 1, 3 and 5 hours. Samples being tested for Vickers hardness, abrasive microwear, microstructure evaluation by optical microscopy and SEM and X-ray diffraction. The results show significant improvement in surface hardness, wear resistance and good formation of expanded austenite layer and no identifiers peaks of carbides. The results achieved are due to diffusion/adsorption of carbon present in the gaseous atmosphere to the evaluated samples. (author)

  7. Modification and characterization of the AISI 410 martensitic stainless steels surface; Modificacao e caracterizacao da superficie do aco inoxidavel martensitico AISI 410

    Energy Technology Data Exchange (ETDEWEB)

    Bincoleto, A.V.L. [Universidade Federal de Sao Carlos (PPG-CEM/UFSCar), SP (Brazil). Programa de Pos-Graduacao em Ciencia e Engenharia de Materiais; Nascente, P.A.P. [Universidade Federal de Sao Carlos (DEMa/UFSCar), SP (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    Steam turbines are used in the generation of more than half the electric energy produced in the world nowadays. It is important the study which aims to improve the efficiency by means of the optimization of leaks and of the aerodynamic profiles, as well as to maintain the integrity of the components. The martensitic stainless steels are widely employed due to the combination of their good mechanical properties with higher corrosion resistance. However, their lower wear resistance and their poor tribological behavior limit their use, since they decrease the component life time. In order to evaluate the improvement in the performance of the AISI 410 stainless steel, several process of surface modification were employed. Five samples were produced: the first one was not treated, the second one received liquid nitriding, the third, gas nitriding, the forth, thermal aspersion of tungsten carbide, and the fifth, boronizing. The samples were characterized by optical microscopy, surface microhardness, and X-ray diffractometry. (author)

  8. Numerical-experimental analysis of a rin AISI{sub 7}Mg Alloy; Analisis numerico experimental de un rin de aleacion AISi{sub 7}Mg

    Energy Technology Data Exchange (ETDEWEB)

    Sauceda Mesa, Israel; Mata Lucero, Omar; Tirado Delgado, Luis; Ocampo Diaz, Juan de Dios [Universidad Autonoma de Baja California, Mexicali, Baja California (Mexico)

    2005-10-15

    The present work shows the results obtained from an investigation mode on the behaviour of a rin of alloy AISi{sub 7}Mg, which is used in compact Volkswagen's cars. Due to two kind of analysis were realized, firstly an experimental and numerical analysis was done, using a special machine for test the flexionante torque and material fatigue, besides was used an equipment of laser to scanner zone with strength concentrations and the maximum displacement amplitudes. The second analysis was done with the finite element technique, using the software ANSYS and CATIA. The difference between life fatigue cycles obtained from the two analyses was 0.6%. While the time optimize by MEF, was of 85% less than experimental analysis. [Spanish] En el presente trabajo se hicieron investigaciones del comportamiento de un rin de aleacion AISi{sub 7}Mg, el cual es usado en automoviles compactos de volkswagen (VW). Para esto, se realizo analisis experimental y numerico. En el primero se utilizo una maquina para prueba de fatiga de momento flexionante, un equipo de medicion de laser escaner donde se detectaron las zonas de concentraciones de esfuerzos y la maxima amplitud de desplazamiento en el rin. Mientras que en el segundo se obtuvieron los esfuerzos que ocasionaban la fatiga por el elemento finito, utilizando los paquetes de computo Ansys y Catia. La diferencia de los ciclos de vida de fatiga obtenidos entre ambos analisis fue del 0.6%. Mientras que el tiempo que se optimizo por el MEF, fue de un 85% menos que el analisis experimental.

  9. Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae.

    Science.gov (United States)

    Kim, Hong-Kyun; Woo, Kyung Mi; Shon, Won-Jun; Ahn, Jin-Soo; Cha, Seunghee; Park, Young-Seok

    2015-01-01

    The aim of this study was to compare osseointegration and surface characteristics of zirconia implants made by the powder injection molding (PIM) technique against those made by the conventional milling procedure in rabbit tibiae. Surface characteristics of 2 types of implants were evaluated. Sixteen rabbits received 2 types of external hex implants with similar geometry, either machined zirconia implants or PIM zirconia implants, in the tibiae. Removal torque tests and histomorphometric analyses were performed. The roughness of the PIM zirconia implants was higher than that of machined zirconia implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined zirconia implants (pmold etching technique, can produce substantially rougher surfaces on zirconia implants.

  10. Influence of implant types on the stress distribution of mandibular flee-end removable partial denture%种植体类型对下颌游离端义齿应力分布的影响

    Institute of Scientific and Technical Information of China (English)

    陈少武; 肖微; 李智勇; 吴敏; 王家伟

    2011-01-01

    目的:观察不同类型种植体-天然牙联合可摘义齿修复Kennedy I类牙列缺损时不同部位的应力和位移.方法:建立16个种植体-天然牙联合可摘义齿修复下颌Kennedy I类牙列缺损的三维有限元模型,在垂直加载条件下比较不同类型(ITI Straumann 和NOBEL ReplaceTMTapered)种植体周围骨组织、基牙牙周膜、基托下黏膜的应力以及基托下黏膜组织的位移变化情况.结果:不论种植体类型,种植体颈部皮质骨为应力集中区域,种植体周围皮质骨内部的最大应力随着种植体长度和直径的增加而减小,基牙牙周膜及基托下黏膜组织的最大应力和位移量无明显变化.同类型种植体直径增加时周围皮质骨最大应力的减小比长度增加时显著;不同类型种植体中,相同长度(6~10 mm变化区间)的直径为4.1 mm(或3.3 mm)的ITIStraumann 种植体周围皮质骨应力低于直径为4.3 mm(或3.5 mm)的NOBEL ReplaceTM Tapered种植体.结论:种植体外形、直径和长度的变化不会影响基牙牙周膜及基托下黏膜组织的应力分布;同类型种植体中,相对于长度而言,更应重视种植体直径的选择;不同类型种植体的外形可能比直径对种植体周围皮质骨应力的影响更大.%Objective: To study the stress distribution and displacement of mandibular free-end removable partial denture with different types of implants.Methods: 16 three-dimensional finite element models of implant-tooth-supporting Kennedy Class Ⅰ removable partial denture were created.Effects of different types of implants( ITI Straumann(R) and NOBEL ReplaceTM Tapered) were evaluated under vertical loading.The variation of displacement of periodontium under saddle and the stress of the bone around implants, the periodontal membrane of abutments and the residual ridge was analysed and compared among the type of implant.Results: No matter how the parameter of implants altered, the stresses within implants

  11. TIG AISI-316 welds using an inert gas welding chamber and different filler metals: Changes in mechanical properties and microstructure

    Directory of Open Access Journals (Sweden)

    Sánchez, A.

    2010-12-01

    Full Text Available This report analyses the influence of the use of an inert gas welding chamber with a totally inert atmosphere on the microstructure and mechanical properties of austenitic AISI 316L stainless steel TIG welds, using AISI ER316L, AISI 308L and Inconel 625 as filler metals. When compared with the typical TIG process, the use of the inert gas chamber induced changes in the microstructure, mainly an increase in the presence of vermicular ferrite and ferrite stringers, what resulted in higher yield strengths and lower values of hardness. Its effect on other characteristics of the joins, such as tensile strength, depended on the filler metal. The best combination of mechanical characteristics was obtained when welding in the inert gas chamber using Inconel 625 as filler metal.

    En este estudio se analiza la influencia que el uso de una cámara de soldadura de gas inerte tiene sobre la microestructura y las propiedades mecánicas de las soldaduras TIG en el acero inoxidable austenítico AISI-316L cuando se emplean AISI ER316L, AISI 308L e Inconel 625 como materiales de aporte. Cuando se compara con el típico proceso de TIG, el uso de una cámara de gas inerte induce cambios en la microestructura, incrementando la presencia de ferrita vermicular y de laminillas de ferrita, resultando en un aumento del límite elástico y una pérdida de dureza. Su influencia sobre otras características de las soldaduras como la carga de rotura depende de la composición del material de aporte. La mejor combinación de propiedades mecánicas se obtuvo usando el Inconel 625 como material de aporte y soldando en la cámara de gas inerte.

  12. Characterization Of Oxide Layers Produced On The AISI 321 Stainless Steel After Annealing

    Directory of Open Access Journals (Sweden)

    Bochnowski W.

    2015-09-01

    Full Text Available In this study, the structure, chemical composition and topography of oxide layers produced on the surface of the AISI 321 austenitic steel in the annealing process were analyzed. Heat treatment was done at 980°C temperature for 1 hour time in different conditions. The annealing was done in a ceramic furnace in oxidation atmosphere and in vacuum furnaces with cylindrical molybdenum and graphite chambers. The analysis was carried out using the following methods: a scanning electron microscope (SEM equipped with an energy-dispersive X-ray spectrometer (EDX, a transmission electron microscope (TEM equipped with an energy-dispersive X-ray spectrometer (EDX, an X-ray diffractometer (XRD, a secondary ion mass spectrometer with time-of-flight mass analyzer (TOF SIMS and an atomic force microscope (AFM. The oxide layer formed during annealing of the AISI 321 steel at 980°C consisted of sub-layers, diversified in the chemical composition. The thickness of the oxidized layer is depended on the annealing conditions. In a ceramic furnace in oxidation atmosphere, the thickness of the oxide layer was of 300-500 nm, in a vacuum furnace with molybdenum and graphite heating chambers, it ranged from 40 to 300 nm and from a few to 50 nm, respectively. TOF SIMS method allows to get average (for the surface of 100 μm × 100 μm depth profiles of concentration of particular elements and elements combined with oxygen. In oxide layers formed in vacuum furnaces there are no iron oxides. Titanium, apart from being bounded with carbon in carbides, is a component of the oxide layer formed on the surface of the AISI 321 steel.

  13. Electrochemical and pitting corrosion resistance of AISI 4145 steel subjected to massive laser shock peening treatment with different coverage layers

    Science.gov (United States)

    Lu, J. Z.; Han, B.; Cui, C. Y.; Li, C. J.; Luo, K. Y.

    2017-02-01

    The effects of massive laser shock peening (LSP) treatment with different coverage layers on residual stress, pitting morphologies in a standard corrosive solution and electrochemical corrosion resistance of AISI 4145 steel were investigated by pitting corrosion test, potentiodynamic polarisation test, and SEM observations. Results showed massive LSP treatment can effectively cause an obvious improvement of pitting corrosion resistance of AISI 4145 steel, and increased coverage layer can also gradually improve its corrosion resistance. Massive LSP treatment with multiple layers was shown to influence pitting corrosion behaviour in a standard corrosive solution.

  14. Resistencia a la abrasión vs. resistencia al impacto del acero aisi 15b30, templado + revenido

    OpenAIRE

    HORACIO SIERRA RESTREPO; DIANA MARCELA TOBÓN

    2008-01-01

    Debido al bajo carbono de los aceros al boro, algunos fabricantes recomiendan el revenido como tratamiento opcional y otros sugieren que no es necesario. Puesto que los aceros al boro son muy utilizados en aplicaciones agrícolas donde tienen exigencias de desgaste e impacto, (p.ej. discos de arados), es, entonces, conveniente evaluar dichas propiedades del acero AISI 15B30 con temple y temple más revenido a diferentes temperaturas y contrastarlo con características del AISI 1030, obtenidas en...

  15. An Electrochemical Impedance Study of AISI 321 Stainless Steel in 0.5 M H2SO4

    Directory of Open Access Journals (Sweden)

    A. Fattah-Alhosseini

    2011-01-01

    Full Text Available The electrochemical behavior of passive films formed on AISI 321 has been examined using electrochemical impedance spectroscopy. AISI 321 is characterized by high interfacial impedance, thereby illustrating its high corrosion resistance. Results showed that the interfacial impedance and the polarization resistance initially increase with applied potential, within the low potential. However, at a sufficiently high potential (>0.6 V, the interfacial impedance and the polarization resistance decrease with increasing potential. The impedance data were adequately represented by an equivalent electrical circuit model based on point defect model, which described the behavior of the passive film on stainless steel more satisfactorily than the proposed models.

  16. PITTING CORROSION OF AISI 316Ti STAINLESS STEEL WITH POLISHED SURFACE

    Directory of Open Access Journals (Sweden)

    Viera Zatkalíková

    2010-05-01

    Full Text Available AISI 316Ti is Cr–Ni–Mo austenitic stainless steel with the high Pitting Resistance Equivalent Number (PREN. The effect of the surface finishing by polishing on the pitting corrosion resistance was tested in aggressive 5% FeCl3 solution. The immersion tests were curried out at the temperature 30, 50, 80 °C. The electrochemical cyclic potentiodynamic tests were carried out in the same solution at temperature 30 and 50 °C. The evaluation of the corrosion resistance arose from the comparison of the results of the immersion and the cyclic potentiodynamic tests.

  17. "CARACTERIZACIÓN Y PROPIEDADES MECANICAS DE LA SOLDADURA DE UN ACERO INOXIDABLE FERRIRICO AISI 430"

    OpenAIRE

    Moreno Rodríguez, Arturo

    2012-01-01

    En la presente trabajo se investiga la soldabilidad del acero inoxidable ferrítico AISI 430. Las propiedades mecánicas y la microestructura se relacionan con las variables operativas del proceso de soldadura, de ahí que jueguen un papel importante para lograr óptimas propiedades. Buscando la mejora de las propiedades mecánicas de las uniones soldadas, posteriormente, se les aplicó un tratamiento térmico post-soldadura. Las uniones se realizaron mediante el proceso de soldadu...

  18. Studies on corrosion protection of laser hybrid welded AISI 316 by laser remelting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Ambat, Rajan; Rasmussen, A.J.

    2005-01-01

    laser surface melting on microstructure and corrosion behaviour of AISI 316L welds. Welding and laser treatment parameters were varied. General corrosion behaviour of the weld and laser treated surface was characterised using a gel visualization test. The local electrochemistry of the weld and laser...... treated surface was investigated using a novel micro electrochemical technique with a tip resolution of ~1 mm. Results show that hybrid laser welding of 316L has increased corrosion susceptibility probably as a result of grain boundary carbide formation. However a suitable post laser treatment could...

  19. Biaxial fatigue tests of notched specimens for AISI 304L stainless steel

    Directory of Open Access Journals (Sweden)

    G. Beretta

    2016-07-01

    Full Text Available High cycle fatigue tests were conducted for stainless steel AISI 304L. The geometry was a thin walled tube with a passing through hole. The tests were axial, torsional and in-phase axial-torsional, all of them under load control with R = −1. The S-N curves were constructed following the ASTM E739 standard and the fatigues limits were calculated following the method of maximum likelihood proposed by Bettinelli. The crack direction along the surface was analysed, with especial attention to the crack initiation zones. The notch fatigue limits for different hole diameters were compared with the predictions done with a microstructural fracture mechanics model.

  20. Active flux tungsten inert gas welding of austenitic stainless steel AISI 304

    OpenAIRE

    Klobčar, D.; J. Tušek; Bizjak, M.; S. Simončič; V. Lešer

    2016-01-01

    The paper presents the effects of flux assisted tungsten inert gas (A-TIG) welding of 4 (10) mm thick austenitic stainless steel EN X5CrNi1810 (AISI 304) in the butt joint. The sample dimensions were 300 ´ 50 mm, and commercially available active flux QuickTIG was used for testing. In the planned study the influence of welding position and weld groove shape was analysed based on the penetration depth. A comparison of microstructure formation, grain size and ferrit number between TIG welding a...

  1. Estructura cristalina del acero AISI 1045 deformado plásticamente

    Directory of Open Access Journals (Sweden)

    Tomás Fernández Columbié

    2008-01-01

    Full Text Available Se abordó el comportamiento microestructural del acero AISI 1045 endurecido mediante la Deformación Plástica Superficial por rodillo, Se establece el mecanismo de endurecimiento del acero por el deslizamiento de los granos en la red cristalina y se demuestra el fenómeno de la acritud, la cual es producto del tensionamiento de los granos cuando el material es sometido al tensionamiento de su estructura cristalina. Se establece el procedimiento experimental realizado después que las probetas fueron sometidas al proceso de deformación.

  2. Estructura cristalina del acero AISI 1045 deformado plásticamente

    OpenAIRE

    Tomás Fernández Columbié; Isnel Rodríguez González; Dayanis Alcántara Borges

    2008-01-01

    Se abordó el comportamiento microestructural del acero AISI 1045 endurecido mediante la Deformación Plástica Superficial por rodillo, Se establece el mecanismo de endurecimiento del acero por el deslizamiento de los granos en la red cristalina y se demuestra el fenómeno de la acritud, la cual es producto del tensionamiento de los granos cuando el material es sometido al tensionamiento de su estructura cristalina. Se establece el procedimiento experimental realizado después que las probetas fu...

  3. Variación microestructural del acero AISI 1045 endurecido por rodadura

    OpenAIRE

    Esther Fernández-Guilarte; Dayanis Alcántara-Borges; Isnel Rodríguez-González; Tomás Fernández-Columbié

    2010-01-01

    En este trabajo se analiza el comportamiento microestructural del acero AISI 1045, endurecido mediante deformación plástica superficial por rodillo, empleando como variables en el proceso de endurecimiento el número de revoluciones, avance y fuerza del torno 16D20. Se empleó el análisis espectral para determinar la composición química del acero y el Nital como reactivo químico para resaltar la estructura metalográfica después de pulida. Se establecen los parámetros de los regímenes de la defo...

  4. Microstructural changes due to laser surface melting of an AISI 304 stainless steel

    Directory of Open Access Journals (Sweden)

    d?Oliveira A.S.C.M.

    2001-01-01

    Full Text Available Several techniques can be used to improve surface properties. These can involve changes on the surface chemical composition (such as alloying and surface welding processes or on the surface microstructure, such as hardening and melting. In the present work surface melting with a 3kW CO2 cw laser was done to alter surface features of an AISI 304 stainless steel. Microstructure characterisation was done by optical and scanning electron microscopy. Vickers and Knoop microhardness tests evaluated mechanical features after surface melting. Phase transformation during rapid solidification is analysed and discussed.

  5. 1020 AISI-SAE steel Austenitic Nitrocarburising with alcohol and triethanolamine

    Directory of Open Access Journals (Sweden)

    Álvaro Castro P

    2010-04-01

    Full Text Available The present work shows AISI-SAE 1020 steel's nitrocarbide layer's microstructure and micro-hardness profile following 4 hours at 700ºC using methanol, isopropanol and triethanolamine. The steel was then hardened by quenching it in water and then tempered at 350ºC for 1 hour. Its surface had been partially oxidised by heating it at 400ºC for 1 hour. An example is given of other researchers analysing microstructure and propierties in steel having 0,5% C, using endothermic gas and different amounts of ammoniac.

  6. Investigating early stages of biocorrosion with XPS: AISI 304 stainless steel exposed to Burkholderia species

    Science.gov (United States)

    Johansson, Leena-Sisko; Saastamoinen, Tuomas

    1999-04-01

    We have investigated the interactions of an exopolymer-producing bacteria, Burkholderia sp. with polished AISI 304 stainless steel substrates using X-ray photoelectron spectroscopy (XPS). Steel coupons were exposed to the pure bacteria culture in a specially designed flowcell for 6 h during which the experiment was monitored in situ with an optical microscope. XPS results verified the formation of biofilm containing extracellular polymer on all the samples exposed to bacteria. Sputter results indicated that some ions needed for metabolic processes were trapped within the biofilm. Changes in the relative Fe concentration and Fe 2p peak shape indicated that also iron had accumulated into the biofilm.

  7. Mechanical Properties of Stellite-6 coated AISI 316L Stainless Steel

    Directory of Open Access Journals (Sweden)

    Pushpinderjit Singh

    2016-01-01

    Full Text Available Present paper describes the mechanical properties of Stellite-6 coated AISI 316 L stainless steel. Specimens were coated using Detonation Gun thermal spray process, with different coating thicknesses of Stellite-6 ranging from 50 µm to 150 µm. Afterwards their properties like tensile strength, impact strength and micro hardness were evaluated on the basis of the results obtained from the experimentation. For comparison of substrate and coated material the graphs were plotted. The coated specimens exhibited superior impact strength and microhardness than that of the bare specimens, whereas the tensile strength of coated specimens decreased marginally with the increase in coating thickness.

  8. Sloped implants applied to different types of jaw bone:A three-dimensional finite element analysis%倾斜种植应用于不同质量颌骨的三维有限元分析

    Institute of Scientific and Technical Information of China (English)

    夏琳; 张志宏; 刘红红; 杜双松; 冯昌乐; 韩倩; 陈佳

    2015-01-01

    24 different inclined angle implant models in different types of bone were established by using three-di-mensional finite element method, vertical loading 300N. The final analysis result was: with increase of implant tilt-ing angle in the same types of bone, the maximum stress and strain of both compact bone and cancellous bone rised gradully. However, when the same angle implant applied to different type of jaw, development trend of maximum stress and strain were:compact bone:Type Ⅳ > Type Ⅲ > Type Ⅱ > Type Ⅰ;cancellous bone:Type Ⅲ > Type Ⅳ> Type Ⅱ.%通过运用三维有限元方法建立Ⅰ~Ⅳ类骨质中种植体不同角度倾斜种植模型24个,垂直集中加载300 N。分析研究显示,在同一骨质中,随着种植体倾斜角度的增加,密质骨和松质骨中的最大应力及应变量均逐渐增大;而相同角度的种植体于不同质量的颌骨中时,最大应力发展趋势为:密质骨:Ⅳ类骨质>Ⅲ类骨质>Ⅱ类骨质>Ⅰ类骨质;松质骨:Ⅲ类骨质>Ⅳ类骨质>Ⅱ类骨质。

  9. ['Which breast implant do I have?'; the importance of the Dutch Breast Implant Registry].

    Science.gov (United States)

    Hommes, Juliëtte; Mureau, Marc A M; Harmsen, Manuel; Rakhorst, Hinne

    2015-01-01

    About 1 in 300 women in the Netherlands has a breast implant but many patients do not know what type of implant was inserted. The quality of breast implants is currently monitored by the implant manufacturers. Sufficient incidents have occurred to show that an independent registry is required to measure the quality of breast implants and to facilitate a national recall, if necessary. Good national and international collaboration with the government, the manufacturers and other specialist associations is crucial for setting up an implant registry. Since April 2015, data about patients and their implants have been collected, independently and prospectively, in the Dutch Breast Implant Registry to increase patient safety in cases of breast implant surgery in the Netherlands.

  10. The effect of CO2 laser beam welded AISI 316L austenitic stainless steel on the viability of fibroblast cells, in vitro.

    Science.gov (United States)

    Köse, Ceyhun; Kaçar, Ramazan; Zorba, Aslı Pınar; Bağırova, Melahat; Allahverdiyev, Adil M

    2016-03-01

    It has been determined by the literature research that there is no clinical study on the in vivo and in vitro interaction of the cells with the laser beam welded joints of AISI 316L biomaterial. It is used as a prosthesis and implant material and that has adequate mechanical properties and corrosion resistance characteristics. Therefore, the interaction of the CO2 laser beam welded samples and samples of the base metal of AISI 316L austenitic stainless steel with L929 fibroblast cells as an element of connective tissue under in vitro conditions has been studied. To study the effect of the base metal and the laser welded test specimens on the viability of the fibroblast cells that act as an element of connective tissues in the body, they were kept in DMEMF-12 medium for 7, 14, 28 days and 18 months. The viability study was experimentally studied using the MTT method for 7, 14, 28 days. In addition, the direct interaction of the fibroblast cells seeded on 6 different plates with the samples was examined with an inverted microscope. The MTT cell viability experiment was repeated on the cells that were in contact with the samples. The statistical relationship was analyzed using a Tukey test for the variance with the GraphPad statistics software. The data regarding metallic ion release were identified with the ICP-MS method after the laser welded and main material samples were kept in cell culture medium for 18 months. The cell viability of the laser welded sample has been detected to be higher than that of the base metal and the control based on 7th day data. However, the laser welded sample's viability of the fibroblast cells has diminished by time during the test period of 14 and 28 days and base metal shows better viability when compared to the laser welded samples. On the other hand, the base metal and the laser welded sample show better cell viability effect when compared to the control group. According to the ICP-MS results of the main material and laser welded

  11. Cochlear Implant

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In this text, the authors recall the main principles and data ruling cochlear implants. Then, a first circle of technical equipment for assistance is presented. This circle includes: device setting (DS), Electrically evoked Auditory Brainstem Responses (EABR), Neural Response Telemetry (NRT), Stapedial Reflex (SR) and Electrodogram Acquisition (EA). This first cycle becomes more and more important as children are implanted younger and younger; the amount of data available with this assistance makes necessary the use of models (implicit or explicit) to handle this information. Consequently, this field is more open than ever.

  12. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  13. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J;

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress.......We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  14. The effect of CO{sub 2} laser beam welded AISI 316L austenitic stainless steel on the viability of fibroblast cells, in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Köse, Ceyhun, E-mail: ceyhun.kose@gop.edu.tr [Faculty of Natural Sciences and Engineering, Department of Mechanical Engineering, Gaziosmanpaşa University, Tokat (Turkey); Kaçar, Ramazan, E-mail: rkacar@karabuk.edu.tr [Faculty of Technology Department of Manufacturing Engineering, Karabuk University, Karabuk 78050 (Turkey); Zorba, Aslı Pınar, E-mail: aslipinarzorba@gmail.com [Graduate School of Natural and Applied Sciences, Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey); Bağırova, Melahat, E-mail: mbagir@yildiz.edu.tr [Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey); Allahverdiyev, Adil M., E-mail: adil@yildiz.edu.tr [Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey)

    2016-03-01

    It has been determined by the literature research that there is no clinical study on the in vivo and in vitro interaction of the cells with the laser beam welded joints of AISI 316L biomaterial. It is used as a prosthesis and implant material and that has adequate mechanical properties and corrosion resistance characteristics. Therefore, the interaction of the CO{sub 2} laser beam welded samples and samples of the base metal of AISI 316L austenitic stainless steel with L929 fibroblast cells as an element of connective tissue under in vitro conditions has been studied. To study the effect of the base metal and the laser welded test specimens on the viability of the fibroblast cells that act as an element of connective tissues in the body, they were kept in DMEMF-12 medium for 7, 14, 28 days and 18 months. The viability study was experimentally studied using the MTT method for 7, 14, 28 days. In addition, the direct interaction of the fibroblast cells seeded on 6 different plates with the samples was examined with an inverted microscope. The MTT cell viability experiment was repeated on the cells that were in contact with the samples. The statistical relationship was analyzed using a Tukey test for the variance with the GraphPad statistics software. The data regarding metallic ion release were identified with the ICP-MS method after the laser welded and main material samples were kept in cell culture medium for 18 months. The cell viability of the laser welded sample has been detected to be higher than that of the base metal and the control based on 7th day data. However, the laser welded sample's viability of the fibroblast cells has diminished by time during the test period of 14 and 28 days and base metal shows better viability when compared to the laser welded samples. On the other hand, the base metal and the laser welded sample show better cell viability effect when compared to the control group. According to the ICP-MS results of the main material and

  15. Structural and Microhardness Changes After Turning of the AISI 1045 Steel for Minimum Quantity Cooling Lubrication

    Science.gov (United States)

    Maruda, Radoslaw W.; Krolczyk, Grzegorz M.; Michalski, Mariusz; Nieslony, Piotr; Wojciechowski, Szymon

    2017-01-01

    This work presents the cooling effect under minimum quantity cooling lubrication and dry cutting on structural changes and microhardness of the ferritic-pearlitic AISI 1045 steel after turning. Due to the fact that the AISI 1045 steel has a two-phase structure, microhardness tests using the Vickers method were conducted with a load of 0.05 HV separately for ferrite and pearlite grains. The tests showed that cooling of the cutting zone under minimum quantity cooling lubrication (MQCL) condition decreased the depth of the hardened layer compared to dry cutting by approximately 40% for both pearlite and ferrite. Scanning electron microscopy analysis revealed that applying MQCL limits the formation of plastic deformations, among others, by reducing the surface crumple zone by approximately 50% compared to dry cutting. As a result of cooling being applied to the cutting zone using the MQCL method, the average diameter of ferrite grains has been decreased in the entire surface area compared to dry cutting. When using dry cutting, clear structural changes of the surface layer were also observed. This may be the result of sulfide inclusions which have formed, causing microcracks on the edge of the hardened layer and surface deformation visible as notches.

  16. Physical and Tribological Properties of Nitrided AISI 316 Stainless Steel Balls

    Directory of Open Access Journals (Sweden)

    Yang Shicai

    2016-01-01

    Full Text Available AISI 316 austenitic stainless steel balls (diameters 5.0 and 12.0 mm, typical hardness 250 HV0.3 and flat samples (20×20×2.0 mm were nitrided by a pulsed glow discharge Ar/N2 plasma. Hardness of the ball surfaces was analysed using Vickers indentation. Thermal stability of the nitrided balls (diameter 12.0 mm was studied using a furnace to heat them in air for 8 hours at temperatures up to 700.0°C and then, after cooling to room temperature, the surface hardness of the heated balls was re-measured. Scanning electron microscopy and X-ray diffraction were used to study the microstructures, composition and phase formation of the nitrided sublayers. Unlubricated pin-on-disc wear testing was used to evaluate the wear resistance of nitrided stainless steel balls (5.0 mm diameter and the results were compared with similar testing on hardened Cr-Steel balls (5 mm diameter with hardness of about 650 HV0.3. All the test results indicated that the nitrided AISI 316 austenitic stainless steel balls have advantages over the hardened Cr-Steel balls in terms of retaining high hardness after heat treatment and high resistance to sliding wear at room temperature under higher counterpart stress. These properties are expected to be beneficial for wide range of bearing applications.

  17. Friction welding of AA6061 to AISI 4340 using silver interlayer

    Directory of Open Access Journals (Sweden)

    Suresh D. Meshram

    2015-09-01

    Full Text Available The present work pertains to the study on joining of AA6061 and AISI 4340 through continuous drive friction welding. The welds were evaluated by metallographic examination, X-ray diffraction, electron probe microanalysis, tensile test and microhardness. The study reveals that the presence of an intermetallic compound layer at the bonded interface exhibits poor tensile strength and elongation. Mg in AA6061 near to the interface is found to be favourable for the formation and growth of Fe2Al5 intermetallics. Introduction of silver as an interlayer through electroplating on AISI 4340 resulted in accumulation of Si at weld interface, replacing Mg at AA6061 side, thereby reducing the width of intermetallic compound layer and correspondingly increasing the tensile strength. Presence of silver at the interface results in partial replacement of Fe–Al based intermetallic compounds with Ag–Al based compounds. The presence of these intermetallics was confirmed by X-ray diffraction technique. Since Ag–Al phases are ductile in nature, tensile strength is not deteriorated and the silicon segregation at weld interface on AA6061 in the joints with silver interlayer acts as diffusion barrier for Fe and further avoids formation of Fe–Al based intermetallics. A maximum tensile strength of 240 MPa along with 4.9% elongation was obtained for the silver interlayer dissimilar metal welds. The observed trends in tensile properties and hardness were explained in relation to the microstructure.

  18. Microstructure and Properties of Plasma Source Nitrided AISI 316 Austenitic Stainless Steel

    Science.gov (United States)

    Li, G. Y.; Lei, M. K.

    2016-11-01

    Plasma source nitriding is a relatively new nitriding technology which can overcome those inherent shortcomings associated with conventional direct current plasma nitriding technology such as the arcing surface damage, the edging effect and the hollow cathode effect. There is considerable study on the properties of nitrided samples for laboratorial scale plasma source nitriding system; however, little information has been reported on the industrial-scale plasma source nitriding system. In this work, AISI 316 austenitic stainless steel samples were nitrided by an industrial-scale plasma source nitriding system at various nitriding temperatures (350, 400, 450 and 500 °C) with a floating potential. A high-nitrogen face-centered-cubic phase (γN) formed on the surface of nitrided sample surface. As the nitriding temperature was increased, the γN phase layer thickness increased, varying from 1.5 μm for the lowest nitriding temperature of 350 °C, to 30 μm for the highest nitriding temperature of 500 °C. The maximum Vickers microhardness of the γN phase layer with a peak nitrogen concentration of 20 at.% is about HV 0.1 N 15.1 GPa at the nitriding temperature of 450 °C. The wear and corrosion experimental results demonstrated that the γN phase was formed on the surface of AISI 316 austenitic stainless steel by plasma source nitriding, which exhibits not only high wear resistance, but also good pitting corrosion resistance.

  19. Improving electrochemical properties of AISI 1045 steels by duplex surface treatment of plasma nitriding and aluminizing

    Energy Technology Data Exchange (ETDEWEB)

    Haftlang, Farahnaz, E-mail: f.haftlang@students.semnan.ac.ir [Department of Metallurgy and Materials Engineering, Faculty of Engineering, Semnan University, Semnan (Iran, Islamic Republic of); Habibolahzadeh, Ali [Department of Metallurgy and Materials Engineering, Faculty of Engineering, Semnan University, Semnan (Iran, Islamic Republic of); Sohi, Mahmoud Heydarzadeh [School of Metallurgy and Materials, College of Engineering, University of Tehran, Tehran (Iran, Islamic Republic of)

    2015-02-28

    Highlights: • AlN coating was applied on AISI 1045 steel via plasma nitriding and aluminizing. • Plasma nitriding and post-aluminizing result in AlN single phase layer on the steel. • PN–Al coated steel had better corrosion resistance than Al–PN one. • Formation of oxide layer provided protection of PN–Al coated steel against corrosion. • Pitting and surface defects was the dominant corrosion mechanism in Al–PN coated steel. - Abstract: Improvement in electrochemical behavior of AISI 1045 steel after applying aluminum nitride coating was investigated in 3.5% NaCl solution, using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) analyses. Aluminum nitride coating was applied on the steel surface by duplex treatment of pack aluminizing and plasma nitriding. Some specimens were plasma nitrided followed by aluminizing (PN–Al), while the others were pack aluminized followed by plasma nitriding (Al–PN). Topological and structural studies of the modified surfaces were conducted using scanning electron microscope (SEM) equipped by energy dispersive X-ray spectroscope (EDS), and X-ray diffractometer (XRD). The electrochemical measurements showed that the highest corrosion and polarization (R{sub p}) resistances were obtained in PN–Al specimens, having single phase superficial layer of AlN. Pitting mechanism was dominant reason of lower corrosion resistance in the Al–PN specimens.

  20. Improvement in cavitation erosion resistance of AISI 316L stainless steel by friction stir processing

    Energy Technology Data Exchange (ETDEWEB)

    Hajian, M. [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Abdollah-zadeh, A., E-mail: zadeh@modares.ac.ir [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Rezaei-Nejad, S.S.; Assadi, H. [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Hadavi, S.M.M. [Department of Materials Science and Engineering, MA University of Technology, Tehran (Iran, Islamic Republic of); Chung, K. [Department of Materials Science and Engineering, Research Institute of Advanced Materials, Engineering Research Institute, Seoul National University, Seoul (Korea, Republic of); Shokouhimehr, M. [Department of Chemical Engineering, College of Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2014-07-01

    Commercial AISI 316L plates with the initial grain size of 14.8 μm were friction stir processed (FSP) with different processing parameters, resulting in two fine-grained microstructures with the grain sizes of 4.6 and 1.7 μm. The cavitation erosion behavior, before and after FSP, was evaluated in terms of incubation time, cumulative mass loss and mean depth of erosion. A separate cavitation erosion test was performed on the transverse cross section of a FSP sample to reveal the effect of grain structure. It was observed that FSP samples, depending on their grain size, are at least 3–6 times more resistant than the base material against cavitation erosion. The improvement in cavitation erosion resistance is attributed to smaller grain structure, lower fraction of twin boundaries, and favorable crystallographic orientation of grains in FSP samples. The finer the grain size, the more cavitation erosion resistance was achieved. Moreover, the microstructures of eroded surfaces were studied using a scanning electron microscope equipped with EBSD, and an atomic force microscope. The mechanisms controlling the cavitation erosion damage in friction stir processed AISI 316L are also discussed.

  1. Evaluation of dynamic fracture mechanics in the AISI 316 stainless steel using instrumented Charpy impact testing

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Juliano Daniel de [Empresa Brasileira de Aeronautica S.A. (EMBRAER), Sao Jose dos Campos, SP (Brazil)]. E-mail: juliano.daniel@embraer.com.br; Rodrigues, Bruno Jardim Franca [Novo Nordisk, Montes Claros, MG (Brazil)]. E-mail: brro@novonordisk.com; Vilela, Jefferson Jose; Martins, Geraldo de Paula [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: gpm@cdtn.br; Carneiro, Jose Rubens Goncalves [Pontificia Universidade Catolica de Minas Gerais (PUC Minas), Belo Horizonte, MG (Brazil)]. E-mail: joserub@pucminas.br

    2007-07-01

    The nuclear power plant's surveillance program is based in Charpy test. But, this test could be used to evaluate integrity's secondary circuit. The steel similar to AISI 316 stainless steel could be used in this circuit. Some secondary circuit's components could be failed in dynamic condition. The dynamic fracture mechanics behavior of the AISI 316 was studied by using instrumented Charpy impact testing. The dynamic fracture toughness (J{sub ld}) could be evaluated by four different methods: compliance changing rate, stretching zone, energy revised and maximum load energy. The tests were made in temperature -196 deg C, room and 200 deg C. At each temperature two specimens were tested. The impact energy was 300 J and the impact velocity was 5.12 m/s. The Charpy specimens 10 x 10 x 50 mm were pre-cracked until 5 mm according to ASTM E-23. Stretching zone size was measured and analyzed by observing the fracture surfaces that were obtained in a scanning electron microscope. The dynamic fracture toughness calculated among four different methods showed a large difference. All studied methods did not agree ASTM E1820 (2001) standard that indicated to plane strain did not occurred in the tip crack. (author)

  2. Determination of Proper Austenitization Temperatures for Hot Stamping of AISI 4140 Steel

    Science.gov (United States)

    Samadian, Pedram; Parsa, Mohammad Habibi; Shakeri, Amid

    2014-04-01

    High strength steels are desirable materials for use in automobile bodies in order to reduce vehicle weight and increase the safety of car passengers, but steel grades with high strength commonly show poor formability. Recently, steels with controlled microstructures and compositions are used to gain adequate strength after hot stamping while maintaining good formability during processing. In this study, microstructure evolutions and changes in mechanical properties of AISI 4140 steel sheets resulting from the hot stamping process at different austenitization temperatures were investigated. To determine the proper austenitization temperatures, the results were compared with those of the cold-worked and cold-worked plus quench-tempered specimens. Comparisons showed that the austenitization temperatures of 1000 and 1100 °C are proper for hot stamping of 3-mm-thick AISI 4140 steel sheets due to the resultant martensitic microstructure which led to the yield and ultimate tensile strength of 1.3 and 2.1 GPa, respectively. Such conditions resulted in more favorable simultaneous strength and elongation than those of hot-stamped conventional boron steels.

  3. PARAMETRIC STUDY OF ELECTRICAL DISCHARGE MACHINING OF AISI 304 STAINLESS STEEL

    Directory of Open Access Journals (Sweden)

    P. SRINIVASA RAO,

    2010-08-01

    Full Text Available Electrical discharge machining (EDM is widely used process in the production of mould / dies, aerospace, automobile and electronics industries where intricate complex shapes need to be machined in very hard materials. The selection of the AISI 304 stainless steel was made taking into account its use in almost all industrial applicationsfor approximately 50% of the world’s stainless steel production and consumption. In this work, a study has been carried out on the influence of four design factors: current, open-circuit voltage, servo and dutycycle over material removal rate, tool wear rate, surface roughness and hardness on the die-sinking electrical discharge machining of AISI 304 stainless steel. This has been done using design of experiments (DOE, which allows us to carry out theabove-mentioned analysis performing a relatively small number of experiments. In this case, a 3*24-1 mixed level factorial design, whose resolution is V, has been selected due to the number of factors considered in the study. The resolution of this mixed factorial design allows us to estimate all the main effects, two-factor interactions and pure quadratic effects of the four design factors selected to perform this study.

  4. Modeling of the flow stress for AISI H13 Tool Steel during Hard Machining Processes

    Science.gov (United States)

    Umbrello, Domenico; Rizzuti, Stefania; Outeiro, José C.; Shivpuri, Rajiv

    2007-04-01

    In general, the flow stress models used in computer simulation of machining processes are a function of effective strain, effective strain rate and temperature developed during the cutting process. However, these models do not adequately describe the material behavior in hard machining, where a range of material hardness between 45 and 60 HRC are used. Thus, depending on the specific material hardness different material models must be used in modeling the cutting process. This paper describes the development of a hardness-based flow stress and fracture models for the AISI H13 tool steel, which can be applied for range of material hardness mentioned above. These models were implemented in a non-isothermal viscoplastic numerical model to simulate the machining process for AISI H13 with various hardness values and applying different cutting regime parameters. Predicted results are validated by comparing them with experimental results found in the literature. They are found to predict reasonably well the cutting forces as well as the change in chip morphology from continuous to segmented chip as the material hardness change.

  5. Dependence of corrosion properties of AISI 304L stainless steel on the austenite grain size

    Energy Technology Data Exchange (ETDEWEB)

    Sabooni, Soheil; Rashtchi, Hamed; Eslami, Abdoulmajid; Karimzadeh, Fathallah; Enayati, Mohammad Hossein; Raeissi, Keyvan; Imani, Reihane Faghih [Isfahan Univ. of Technology, Isfahan (Iran, Islamic Republic of). Dept. of Materials Engineering; Ngan, Alfonso Hing Wan [The Univ. of Hong Kong (China). Dept. of Mechanical Engineering

    2017-07-15

    The corrosion resistance of austenitic stainless steels is known to be hampered by the loss of chromium available for passive surface layer formation as a result of chromium carbide precipitation at austenite grain boundaries during annealing treatments. Although high-temperature annealing can promote carbide dissolution leading to better corrosion resistance, grain coarsening also results, which would lead to poorer mechanical properties. Processing methods to achieve both good corrosion resistance and mechanical properties are thus highly desirable for austenitic stainless steels. In the present study, we show that the corrosion resistance of AISI 304L stainless steel can be improved by grain refinement into the ultrafine-grained regime. Specifically, samples with different austenite grain sizes in the range of 0.65-12 μm were studied by potentiodynamic polarization and electrochemical impedance spectroscopy tests in a 3.5 wt.% NaCl solution. All samples showed a typical passive behavior with similar corrosion potential, but the corrosion current density decreased significantly with decreasing grain size. The results show that the sample with the finest grain size had the best corrosion resistance due to a higher resistance of the passive layer to pitting attacks. This study indicates that grain refinement which improves mechanical properties can also significantly improve the corrosion resistance of AISI 304L stainless steel.

  6. Statistical regression modeling and machinability study of hardened AISI 52100 steel using cemented carbide insert

    Directory of Open Access Journals (Sweden)

    Amlana Panda

    2017-01-01

    Full Text Available The present study investigates performance and feasibility of application of low cost cemented carbide insert in dry machining of AISI 52100 steel hardened to (55 ± 1 HRC which is rarely researched as far as machining of bearing steel is concerned. Machinability studies i.e. flank wear, surface roughness and morphology analysis of chip has been investigated and statistical regression modeling has been developed. The test has been conducted based on Taguchi L16 OA taking machining parameters like cutting speed, feed and depth of cut. It is observed that uncoated cemented carbide insert performs well at some selected runs (Run 1, 5 and 9 which show its feasibility for hard turning applications. The developed serrated saw tooth chip of burnt blue colour adversely affects the surface quality. Adequacy of the developed statistical regression model has been checked using ANOVA analysis (depending on F value, P value and R2 value and normal probability plot at 95% confidence level. The results of optimal parametric combinations may be adopted while turning hardened AISI 52100 steel under dry environment with uncoated cemented carbide insert.

  7. Influence of dissolved hydrogen on the fatigue crack growth behaviour of AISI 4140 steel

    Science.gov (United States)

    Ramasagara Nagarajan, Varun

    Many metallic structural components come into contact with hydrogen during manufacturing processes or forming operations such as hot stamping of auto body frames and while in service. This interaction of metallic parts with hydrogen can occur due to various reasons such as water molecule dissociation during plating operations, interaction with atmospheric hydrogen due to the moisture present in air during stamping operations or due to prevailing conditions in service (e.g.: acidic or marine environments). Hydrogen, being much smaller in size compared to other metallic elements such as Iron in steels, can enter the material and become dissolved in the matrix. It can lodge itself in interstitials locations of the metal atoms, at vacancies or dislocations in the metallic matrix or at grain boundaries or inclusions (impurities) in the alloy. This dissolved hydrogen can affect the functional life of these structural components leading to catastrophic failures in mission critical applications resulting in loss of lives and structural component. Therefore, it is very important to understand the influence of the dissolved hydrogen on the failure of these structural materials due to cyclic loading (fatigue). For the next generation of hydrogen based fuel cell vehicles and energy systems, it is very crucial to develop structural materials for hydrogen storage and containment which are highly resistant to hydrogen embrittlement. These materials should also be able to provide good long term life in cyclic loading, without undergoing degradation, even when exposed to hydrogen rich environments for extended periods of time. The primary focus of this investigation was to examine the influence of dissolved hydrogen on the fatigue crack growth behaviour of a commercially available high strength medium carbon low alloy (AISI 4140) steel. The secondary objective was to examine the influence of microstructure on the fatigue crack growth behaviour of this material and to determine the

  8. Exploring Effectiveness of Computer-Aided Planning in Implant Positioning for a Single Immediate Implant Placement.

    Science.gov (United States)

    Edelmann, Alexander R; Hosseini, Bashir; Byrd, Warren C; Preisser, John S; Tyndall, Donald A; Nguyen, Tung; Bencharit, Sompop

    2016-06-01

    The value of computer-aided implant planning using cone-beam computerized tomography (CBCT) for single immediate implants was explored. Eighteen patients requiring extraction of a tooth followed by a single immediate implant were enrolled. Small volume preoperative CBCT scans were used to plan the position of the implant. A taper screwed-type implant was immediately placed into a fresh socket using only the final 1 or 2 drills for osteotomy. Postoperative CBCTs were used for the analysis of actual implant placement positioning. Measurements of the planned and the actual implant position were made with respect to their position relative to the adjacent teeth. Mesio-distal displacements and the facial-lingual deviation of the implant from the planned position were determined. Changes in the angulation of the planned and actual implant position in relation to the clinical crown were also measured. To statistically summarize the results, box plots and 95% CIs for means of paired differences were used. The analysis showed no statistical difference between the planned position and final implant placement position in any measurement. The CBCT scans coupled with the computer-aided implant planning program along with a final 1-to-2 drill protocol may improve the accuracy of single immediate implant placement for taper screwed-type implants.

  9. Cytological Diagnosis of Bilateral Breast Implant-Associated Lymphoma of the ALK-Negative Anaplastic Large-Cell Type. Clinical Implications of Peri-Implant Breast Seroma Cytological Reporting.

    Science.gov (United States)

    Granados, Rosario; Lumbreras, Eva M; Delgado, Manuel; Aramburu, José A; Tardío, Juan C

    2016-07-01

    The cytological examination of peri-prosthetic breast effusions allowed the diagnosis of bilateral breast-implant ALK-negative anaplastic large cell lymphoma (BI-ALCL) in the case reported. Ten years after reconstructive surgery with bilateral breast implants, a large unilateral seroma developed and was cytologically analyzed. The presence of CD30 and CD4-positive large-sized atypical lymphoid cells exhibiting horseshoe-shaped nuclei and a brisk mitotic activity rendered the diagnosis of BI-ALCL. Similar cells were seen in the peri-prosthetic fluid intraoperatively collected from the contralateral breast. Although initial histological analysis of the capsulectomy specimens showed unilateral tumor, the cytological findings prompted a more thorough tissue sampling, resulting in the diagnosis of bilateral disease. BI-ALCL usually follows an indolent clinical course; however, there are reported cases with an aggressive behavior. While the presence of bilateral disease is a putative risk factor for a bad prognosis, the small number of cases reported precludes a definitive assessment of this risk. Since most BI-ALCL present with late seromas, cytologic analysis of these effusions in women with breast implants should be mandatory. Cytology is a safe tool for diagnosis and follow-up of patients with breast implant-related late seromas, sometimes proven more sensitive than histological analysis. Complete bilateral capsulectomy and a detailed histological analysis should follow a cytological diagnosis of BI-ALCL in a breast effusion in order to avoid false negative diagnoses. Our case constitutes the first published report of a bilateral BI-ALCL diagnosed by cytology. Diagn. Cytopathol. 2016;44:623-627. © 2016 Wiley Periodicals, Inc.

  10. In-situ investigation of martensite formation in AISI 52100 bearing steel at sub-zero Celsius temperature

    DEFF Research Database (Denmark)

    Villa, Matteo; Hansen, Mikkel Fougt; Pantleon, Karen

    2013-01-01

    Martensite formation in AISI 52100 bearing steel at sub-zero Celsius temperature was investigated with Vibrating Sample Magnetometry. The investigation reports the stabilization of retained austenite in quenched samples during storage at room temperature and reveals the thermally activated nature...

  11. The effect of cladding speed on phase constitution and properties of AISI 431 stainless steel laser deposited coatings

    NARCIS (Netherlands)

    Hemmati, I.; Ocelik, V.; De Hosson, J. Th. M.

    2011-01-01

    Shorter processing time has given impetus to laser cladding technology and therefore in this research the AISI 431 martensitic stainless steel coatings are laser deposited at high cladding speeds, i.e. up to 117 mm/s. The analysis of phase constitution and functional properties of the coatings are p

  12. Investigation on the Tribology of Co Implanted Stainless Steel Using Metal Vapor Vacuum Arc Ion Source

    Institute of Scientific and Technical Information of China (English)

    Junxia GUO; Xun CAI; Qiulong CHEN

    2004-01-01

    AISI 304 stainless steel was ion implanted with Co, and the tribological property on the surface of the stainless steel was investigated. The Co ion implantation was carried out using a metal vapor vacuum arc (Mevva) broad-beam ion source with an extraction voltage of 40 kV, implantation doses of 3×1017/cm2 and 5×1017/cm2, and ion current densities of 13, 22 and 32 μA/cm2. The results showed that the near-surface hardness of Co-implanted stainless steel sample was increased by 50% or more, and it increased with increasing ion current density at first and then declined. The friction coefficient decreased from 0.74 to 0.20 after Co implantation. The wear rate after Co implantation reduced by 25% or more as compared to the unimplanted sample. The wear rate initially decreased with increasing ion current density and then an increase was observed. Within the range of experimental parameters, there exists a critical ion current density for the Co-implanted stainless steel, at which the wear rate decreased with increasing retained dose, going through a minimum and then increased. The critical ion current density in this paper is about 22 μA/cm2.

  13. Optimization of Minimum Quantity Lubricant Conditions and Cutting Parameters in Hard Milling of AISI H13 Steel

    Directory of Open Access Journals (Sweden)

    The-Vinh Do

    2016-03-01

    Full Text Available As a successful solution applied to hard machining, the minimum quantity lubricant (MQL has already been established as an alternative to flood coolant processing. The optimization of MQL parameters and cutting parameters under MQL condition are essential and pressing. The study was divided into two parts. In the first part of this study, the Taguchi method was applied to find the optimal values of MQL condition in the hard milling of AISI H13 with consideration of reduced surface roughness. The L9 orthogonal array, the signal-to-noise (S/N ratio and analysis of variance (ANOVA were employed to analyze the effect of the performance characteristics of MQL parameters (i.e., cutting fluid type, pressure, and fluid flow on good surface finish. In the results section, lubricant and pressure of MQL condition are determined to be the most influential factors which give a statistically significant effect on machined surfaces. A verifiable experiment was conducted to demonstrate the reliability of the results. In the second section, the optimized MQL parameters were applied in a series of experiments to find out cutting parameters of hard milling. The Taguchi method was also used to optimize the cutting parameters in order to obtain the best surface roughness. The design of the experiment (DOE was implemented by using the L27 orthogonal array. Based on an analysis of the signal-to-noise response and ANOVA, the optimal values of cutting parameters (i.e., cutting speed, feed rate, depth-of-cut and hardness of workpiece were introduced. The results of the present work indicate feed rate is the factor having the most effect on surface roughness.

  14. What do sales data tell us about implant survival?

    Science.gov (United States)

    Seemann, Rudolf; Jirku, Alexander; Wagner, Florian; Wutzl, Arno

    2017-01-01

    Objective The aim of this study was to evaluate the influence of implant diameter, length and shape on a surrogate parameter of implant survival; i.e. the implant return rate in a big data analysis. Materials and methods A retrospective study was conducted and the factors influencing the success rates of 69,377 sold implants over a seven-year period were evaluated. The osseointegration program of a reseller provides reliable data of a single country. Implant loss rates were investigated using logistic regression models and regressed by implant type, diameter, and length. Results The return rate of 69,377 sold implants was 2.78% and comparable to implant loss rates in previous published prospective studies as its surrogate parameter. A total of 80% of implant returns had occurred within 157 days, and an additional 15% within 750.25 days. Diameters of 3.8 to 5.0mm showed the lowest return rates with its bottom in the 4.3mm implant whilst 6.0mm implants had significantly higher return rates. In comparison to the most sold implant length (13mm) shorter implants showed significantly higher early return rates. Conclusions The study provides evidence that in cases of standard indications and sufficient bone, the use of screw typed dental implants with 3.8 or 4.3 diameter and 11 or 13 mm length shows the lowest implant return rates. Other implants may be selected only in specific indications. PMID:28222128

  15. 花瓣式巩膜成形包裹义眼台的临床应用%Clinical application of petal type scleroplasty package of orbital socket implant

    Institute of Scientific and Technical Information of China (English)

    蔡卫华; 周小红; 陈诗雅; 章梦娴

    2014-01-01

    目的 探讨花瓣式巩膜成形包裹国产羟基磷灰石(HA)义眼台在眼内容摘除术中的应用体会.方法 对48例眼内容摘除者行花瓣式巩膜成形包裹国产HA义眼台植入术,术后随访6 ~24个月,观察手术效果.结果 48例中仅有2例出现轻度结膜囊狭窄,所有病例均未发现义眼台暴露、脱出或感染等严重并发症.结论 巩膜花瓣式成形包裹国产HA义眼台植入术方便易行,术后并发症少,义眼台活动佳,疗效好.%Objective To investigate the application of petal type scleroplasty package of domestic HA orbital socket implant during eyeball evisceration surgery.Methods Petal type scleroplasty package of domestic HA was implanted in 48 cases of eyeball evisceration.Patients were followed up for 6-24 months,and the postoperative effect was observed.Results Of 48 patients,mild conjunctival sac stenosis occurred in 2 patients.Severe complications,such as implant exposure,extrusion or infection,were not found in all patients.Conclusion Scleral petal type molded package of domestic HA implant is convenient and effective with few postoperative complications.

  16. A Histologic Evaluation on Tissue Reaction to Three Implanted Materials (MTA, Root MTA and Portland Cement Type I in the Mandible of Cats

    Directory of Open Access Journals (Sweden)

    F. Sasani

    2004-09-01

    Full Text Available Statement of Problem: Nowadays Mineral Trioxide aggregate (MTA is widely used for root end fillings, pulp capping, perforation repair and other endodontic treatments.Investigations have shown similar physical and chemical properties for Portland cement and Root MTA with those described for MTA.Purpose: The aim of this in vitro study was to evaluate the tissue reaction to implanted MTA, Portland cement and Root MTA in the mandible of cats.Materials and Methods: Under asepsis condition and general anesthesia, a mucoperiosteal flap, following the application of local anesthesia, was elevated to expose mandibular symphysis. Two small holes in both sides of mandible were drilled. MTA, Portland cement and Root MTA were mixed according to the manufacturers, recommendation and placed in bony cavities. In positive control group, the test material was Zinc oxide powder plus tricresoformalin. In negative control group, the bony cavities were left untreated. After 3,6 and 12 weeks, the animals were sacrificed and the mandibular sections were prepared for histologic examination under light microscope. The presence and thickness of inflammation, presence of fibrosis capsule, the severity of fibrosis and bone formation were investigated. The data were submitted to Exact Fisher test, chi square test and Kruskal-Wallis test for statistical analysis.Results: No statistically significant differences were found in the degree of inflammation,presence of fibrotic capsule, severity of fibrosis and inflammation thickness between Root MTA, Portland cement and MTA (P>0.05. There was no statistical difference in boneformation between MTA and Portland cement (P>0.05. However, bone formation was not found in any of the Root MTA specimens and the observed tissue was exclusively of fibrosis type.Conclusion: The physical and histological results observed with MTA are similar to those of Root MTA and Portland cement. Additionally, all of these three materials are biocompatible

  17. Dental implant restoration in 248 patients with periodontal disease and type 2 diabetes%牙周病伴2型糖尿病248例种植义齿治疗总结

    Institute of Scientific and Technical Information of China (English)

    吴大怡; 李刚; 张青; 滕立钊; 卢焕友

    2011-01-01

    Objective To discuss the risk and strategy of dental implantation in patients with periodontal disease and type 2 diabetes.Methods Retrospective analysis was performed of dental implantation results in 248 patients with periodontal disease and type 2 diabetes from 2000 to 2008.The survival rate was evaluated and the data statistically analyzed.Results The Nobel implant system and CDIC implant system were used.The operation applied flapless and bone expanding techniques.A total of 1190 implants were inserted (333 Nobel Replace implants and 857 CDIC implants).0.5% (6 implants) lost during the first 6 months healing stage.The l-year,5-year and 8-year survival rate were 98.4% (1165/1184),95.3%(487/511)and 89.2%(91/102) respectively.Conclusions The patients with periodontal disease and type 2 diabetes are suitable for implant treatment with satisfactory results under the conditions that the indication and risk factors are evaluated and controlled strictly.%目的 探讨牙周病伴2型糖尿病患者实施种植义齿治疗的风险和处理对策.方法 回顾分析2000至2008年在成都华西牙种植医院、华西口腔深圳门诊部、华西口腔重庆门诊部接受种植义齿治疗的248例牙周病伴2型糖尿病患者,以种植体存留率为评价指标,对数据进行统计分析.结果 248例患者选用Nobel Replace和CDIC两个种植系统,采用不翻瓣和骨膨胀的微创植入术,共植入牙种植体1190枚(Nobel Replace 333枚、CDIC 857枚).6枚(0.5%)种植体在术后6个月愈合期内脱落,术后1年种植体存留率为98.4% (1165/1184)、5年存留率为95.3% (487/511)、8年存留率为89.2% (91/102).结论 严格掌握适应证和控制风险的情况下,牙周病伴2型糖尿病患者种植修复可获得较高的满意度.

  18. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  19. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2016-10-14

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Análisis térmico de soldadura GTAW sobre placa de acero AISI 316L empleando el método de elementos finitos GTAW welding thermal analysis on AISI 316L steel plate using the finite elements method

    Directory of Open Access Journals (Sweden)

    Juan A. Pozo-Morejón

    2011-09-01

    Full Text Available En el presente trabajo se realiza la modelación térmica de soldadura GTAW sobre placa de acero inoxidable AISI 316L. Se analizan los aspectos teóricos más relevantes a considerar durante la ejecución de un análisis de este tipo. En la simulación se emplea un software de análisis por elementos finitos de uso general y se enriquece una metodología, previamente desarrollada, para la modelación en 3D no lineal transitoria del proceso de soldeo. En dicha metodología se implementa una subrutina en lenguaje APDL, programada con el modelo volumétrico de fuente calor de doble elipsoide, en un sistema de coordenadas cartesiano. Se analiza la influencia del paso de tiempo seleccionado sobre los resultados de la simulación. Finalmente se valida la metodología enriquecida, en base a la correlación de los resultados del modelo respecto a los resultados experimentales.In the present work, thermal modeling of GTAW welding on AISI 316L stainless steel plate is presented. More relevant theoretical aspects to be considered during the implementation of an analysis of this type are discussed. For the simulation a general purpose finite element analysis software has been used. A previously developed methodology for 3D nonlinear transient modeling of welding process has also been improved. In this methodology a subroutine in APDL language is implemented, programmed with the double ellipsoid volumetric heat source model, in a Cartesian coordinated system. The influence of the selected time step on the simulation results is analyzed. The good correlation obtained among the results calculated by means of the model and the experimental data validates this improved methodology.

  1. Resistencia al desgaste de recubrimientos Fe-Nb-Cr-W, Nb, AISI 1020 y AISI 420 producidos por proyección térmica por arco eléctrico

    Directory of Open Access Journals (Sweden)

    López-Covaleda, E. A.

    2013-10-01

    Full Text Available The commercial materials 140MXC (with iron, tungsten, chrome, niobium, 530AS (AISI 1015 steel and 560AS (AISI 420 steel on AISI 4340 steel were deposited using thermal spray with arc. The aim of work was to evaluate the best strategy abrasive wear resistance of the system coating-substrate using the following combinations: (1 homogeneous coatings and (2 coatings depositing simultaneously 140MXC + 530AS and 140MXC + 560AS. The coatings microstructure was characterized using Optical microscopy, Scanning electron microscopy and Laser confocal microscopy. The wear resistance was evaluated through dry sand rubber wheel test (DSRW. We found that the wear resistance depends on the quantity of defects and the mechanical properties like hardness. For example, the softer coatings have the biggest wear rates and the failure mode was characterized by plastic deformation caused by particles indentation, and the other hand the failure mode at the harder materials was grooving. The details and wear mechanism of the coatings produced are described in this investigation.Mediante proyección térmica de arco eléctrico fueron depositados tres materiales comercialmente conocidos como: 140MXC (a base de hierro, wolframio, cromo y niobio, 530AS (acero AISI 1020 y 560AS (acero AISI 420, sobre acero AISI 4340. Con el objetivo de evaluar la mejor estrategia para incrementar la resistencia al desgaste abrasivo, los recubrimientos fueron depositados de dos formas: (1 monocapas homogéneas de cada material y (2 recubrimientos depositando con alambres disimiles de 140MXC + 530AS y 140MXC + 560AS. Los recubrimientos fueron caracterizados microestructuralmente mediante Difracción de rayos X, Microscopía óptica, Microscopía láser confocal y Microscopía electrónica de barrido. La evaluación de la resistencia al desgaste abrasivo se realizó mediante ensayo con arena seca y rueda de caucho (DSRW. Se encontró que la resistencia al desgaste depende entre otras de las

  2. Functional outcome of auditory implants in hearing loss.

    Science.gov (United States)

    Di Girolamo, S; Saccoccio, A; Giacomini, P G; Ottaviani, F

    2007-01-01

    The auditory implant provides a new mechanism for hearing when a hearing aid is not enough. It is the only medical technology able to functionally restore a human sense i.e. hearing. The auditory implant is very different from a hearing aid. Hearing aids amplify sound. Auditory implants compensate for damaged or non-working parts of the inner ear because they can directly stimulate the acoustic nerve. There are two principal types of auditory implant: the cochlear implant and the auditory brainstem implant. They have common basic characteristics, but different applications. A cochlear implant attempts to replace a function lost by the cochlea, usually due to an absence of functioning hair cells; the auditory brainstem implant (ABI) is a modification of the cochlear implant, in which the electrode array is placed directly into the brain when the acoustic nerve is not anymore able to carry the auditory signal. Different types of deaf or severely hearing-impaired patients choose auditory implants. Both children and adults can be candidates for implants. The best age for implantation is still being debated, but most children who receive implants are between 2 and 6 years old. Earlier implantation seems to perform better thanks to neural plasticity. The decision to receive an implant should involve a discussion with many medical specialists and an experienced surgeon.

  3. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  4. [Implantation in severe myopia cataract].

    Science.gov (United States)

    Metge, P; Ginestet, X; Morin, B; Platon, O

    1989-01-01

    Based upon biometric and statistical analysis of 163 eyes (26 mm or longer), it appears that high myopia cataract occur all the earlier as the eye is long; on average, these were operated on ten years earlier than cataracts in the general population. Extra-capsular extraction and intercapsular implantation were generally used. Pre and post-operative complications are remarkably rare for such abnormal eyes. After a mean period of 22 months, detachment of the retina was observed in 1.84% of patients and secondary capsulotomy performed in 8%. Because they prevent secondary capsular opacification and anterior vitreous propagation, it appears that such barrier-type implants should be systematically placed. Current large-diameter implants allow for vitreoretinal observation. Based upon this patient population, a formula for implant power calculation specific to high myopia has been elaborated. The desired degree of refraction varies with age and patient activity.

  5. Variación microestructural del acero AISI 1045 endurecido por rodadura

    Directory of Open Access Journals (Sweden)

    Esther Fernández-Guilarte

    2010-03-01

    Full Text Available En este trabajo se analiza el comportamiento microestructural del acero AISI 1045, endurecido mediante deformación plástica superficial por rodillo, empleando como variables en el proceso de endurecimiento el número de revoluciones, avance y fuerza del torno 16D20. Se empleó el análisis espectral para determinar la composición química del acero y el Nital como reactivo químico para resaltar la estructura metalográfica después de pulida. Se establecen los parámetros de los regímenes de la deformación plástica superficial por rodillo para evaluar la dureza de los pasadores utilizados en las esteras de los equipos de laboreo minero y se expone una metodología para determinar el tiempo de ejecución del corte de las muestras.

  6. Stress corrosion cracking of AISI 321 stainless steel in acidic chloride solution

    Indian Academy of Sciences (India)

    Yanliang Huang

    2002-02-01

    The stress corrosion cracking (SCC) of AISI 321 stainless steel in acidic chloride solution was studied by slow strain rate (SSR) technique and fracture mechanics method. The fractured surface was characterized by cleavage fracture. In order to clarify the SCC mechanism, the effects of inhibitor KI on SCC behaviour were also included in this paper. A study showed that the inhibition effects of KI on SCC were mainly attributed to the anodic reaction of the corrosion process. The results of strain distribution in front of the crack tip of the fatigue pre-cracked plate specimens in air, in the blank solution (acidic chloride solution without inhibitor KI) and in the solution added with KI measured by speckle interferometry (SPI) support the unified mechanism of SCC and corrosion fatigue cracking (CFC).

  7. Quantifying Cutting and Wearing Behaviors of TiN- and CrNCoated AISI 1070 Steel

    Directory of Open Access Journals (Sweden)

    Ahmet Cakan

    2008-11-01

    Full Text Available Hard coatings such as titanium nitride (TiN and chromium nitride (CrN are widely used in cutting and forming tools against wear and corrosion. In the present study, hard coating films were deposited onto AISI 1070 steels by a cathodic arc evaporation plating (CAVP technique. These samples were subjected to wear in a conventional lathe for investigating the tribological behaviour of coating structure, and prenitrided subsurface composition was characterized using scanning electron microscopy (SEM, line scan analyses and X-ray diffraction (XRD. The wear properties of TiN- and CrNcoated samples were determined using an on-line monitoring system. The results show that TiN-coated samples demonstrate higher wear resistance than CrN-coated samples.

  8. Quantifying Cutting and Wearing Behaviors of TiN- and CrNCoated AISI 1070 Steel.

    Science.gov (United States)

    Cakan, Ahmet; Ozkaner, Vedat; Yildirim, Mustafa M

    2008-11-05

    Hard coatings such as titanium nitride (TiN) and chromium nitride (CrN) are widely used in cutting and forming tools against wear and corrosion. In the present study, hard coating films were deposited onto AISI 1070 steels by a cathodic arc evaporation plating (CAVP) technique. These samples were subjected to wear in a conventional lathe for investigating the tribological behaviour of coating structure, and prenitrided subsurface composition was characterized using scanning electron microscopy (SEM), line scan analyses and X-ray diffraction (XRD). The wear properties of TiN- and CrNcoated samples were determined using an on-line monitoring system. The results show that TiN-coated samples demonstrate higher wear resistance than CrN-coated samples.

  9. Microstructure and Hardness of High Temperature Gas Nitrided AISI 420 Martensitic Stainless Steel

    Directory of Open Access Journals (Sweden)

    Ibrahim Nor Nurulhuda Md.

    2014-07-01

    Full Text Available This study examined the microstructure and hardness of as-received and nitrided AISI 420 martensitic stainless steels. High temperature gas nitriding was employed to treat the steels at 1200°C for one hour and four hours using nitrogen gas, followed by furnace cooled. Chromium nitride and iron nitride were formed and concentrated at the outmost surface area of the steels since this region contained the highest concentration of nitrogen. The grain size enlarged at the interior region of the nitrided steels due to nitriding at temperature above the recrystallization temperature of the steel and followed by slow cooling. The nitrided steels produced higher surface hardness compared to as-received steel due to the presence of nitrogen and the precipitation of nitrides. Harder steel was produced when nitriding at four hours compared to one hour since more nitrogen permeated into the steel.

  10. Effect of plasma nitriding time on surface properties of hard chromium electroplated AISI 1010 steel

    Energy Technology Data Exchange (ETDEWEB)

    Kocabas, Mustafa [Yildiz Technical Univ., Istanbul (Turkey). Metallurgical and Materials Engineering Dept.; Danisman, Murat [Gedik Univ., Istanbul (Turkey). Electrical and Electronic Engineering Dept.; Cansever, Nurhan [Yildiz Technical Univ., Istanbul (Turkey); Uelker, Suekrue [Afyon Kocatepe Univ. (Turkey). Dept. of Mechanical Engineering

    2015-06-01

    Properties of steel can be enhanced by surface treatments such as coating. In some cases, further treatments such as nitriding can also be used in order to get even better results. In order to investigate the properties of nitride layer on hard Cr coated AISI 1010 steel, substrates were electroplated to form hard Cr coatings. Then hard Cr coatings were plasma nitrided at 700 C for 3 h, 5 h and 7 h and nitride phases on the coatings were investigated by X-ray diffraction analysis. The layer thickness and surface properties of nitride films were investigated by scanning electron microscopy. The hardness and adhesion properties of Cr-N phases were examined using nano indentation and Daimler-Benz Rockwell C adhesion tests. The highest measured hardness was 24.1 GPa and all the three samples exhibited poor adhesion.

  11. Diffusion characteristics of plasma nitrided hard chromium on AISI 1010 steel

    Energy Technology Data Exchange (ETDEWEB)

    Danisman, Murat [Gedik Univ., Istanbul (Turkey). Electronic Engineering Dept.; Kocabas, Mustafa; Cansever, Nurhan [Yildiz Technical Univ., Istanbul (Turkey)

    2015-06-01

    In order to investigate the different Cr-N formation characteristics of plasma nitrided hard Cr coatings, Cr was electrodeposited on AISI 1010 steel and plasma nitrided at 600, 700 and 800 C for 3 h, 5 h and 7 h, respectively. Phase analyses of resulting Cr-N phases and grain size of Cr layer before and after nitriding process were calculated by X-ray diffraction analysis. Structure of nitride layer and its thickness were analyzed using scanning electron microscopy micrographs. The micrographs indicated that samples consisted of three distinctive layers. In order to distinguish these layers, scanning electron microscopy and energy dispersive spectroscopy (EDX) analysis were used as well as elemental distribution versus depth was plotted. The Cr-N diffusion was investigated by layer thickness measurements, and diffusion coefficient as well as activation energies were calculated.

  12. Optimization of process parameters of ECM by RSM on AISI 202 steel

    Directory of Open Access Journals (Sweden)

    P. Alex John Britto

    2015-12-01

    Full Text Available The machining of complex shaped designs was difficult earlier, but with the advent of the newer machining processes incorporating in it electrical, chemical & mechanical processes, manufacturing has redefined itself. Especially, the Electrochemical Machining (ECM process is used to machine the hard to cut materials without producing heat and friction. Hence, in this work, the ECM process has been chosen to machine SS AISI 202 steel. This study establishes the effect of process parameters such as voltage, current and concentration of electrolyte on the responses on material removal rate (MRR. In this work, second-order quadratic models were developed for MRR, considering the electrolyte concentration, voltage and current as the machining parameters, using central composite design. The developed models were used for Response Surface Methodology (RSM optimization by desirability function approach to determine the optimum machining parameters.

  13. Martensitic Transformation during Fatigue Testing of an AISI 301LN Stainless Steel

    Science.gov (United States)

    Mateo, A.; Fargas, G.; Zapata, A.

    2012-02-01

    The plastic deformation accumulated during fatigue testing can induce the transformation of austenite to martensite in metastable austenitic stainless steels. To analyze this issue, a metastable austenitic stainless steel grade AISI 301 LN was studied in two different conditions, i.e. annealed and cold rolled. In the first case, the steel was fully austenitic, whereas cold rolled material had almost 30% of martensite. High cycle fatigue tests at a stress ratio of 0.8 were carried out on flat specimens from both steel conditions. Several characterization techniques, including optical microscopy, X-ray diffraction (XRD) and electron back scattered diffraction (EBSD), were used to detect and quantify the martensite induced by the cyclic deformation.

  14. Active flux tungsten inert gas welding of austenitic stainless steel AISI 304

    Directory of Open Access Journals (Sweden)

    D. Klobčar

    2016-10-01

    Full Text Available The paper presents the effects of flux assisted tungsten inert gas (A-TIG welding of 4 (10 mm thick austenitic stainless steel EN X5CrNi1810 (AISI 304 in the butt joint. The sample dimensions were 300 ´ 50 mm, and commercially available active flux QuickTIG was used for testing. In the planned study the influence of welding position and weld groove shape was analysed based on the penetration depth. A comparison of microstructure formation, grain size and ferrit number between TIG welding and A-TIG welding was done. The A-TIG welds were subjected to bending test. A comparative study of TIG and A-TIG welding shows that A-TIG welding increases the weld penetration depth.

  15. Analysis of deformation induced martensite in AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Jagarinec, Darko; Kirbis, Peter; Predan, Jozef; Vuherer, Tomaz; Gubeljak, Nenad [Maribor Univ. (Slovenia). Faculty of Mechanical Engineering

    2016-08-01

    Metastable austenite stainless steel AISI 316L is sensitive to cold deformation, where transformation from austenite to martensite occurred. The bending deformation as the formation process leads to tensile and compression throughout the thickness of the billet. Tensile testing of the specimen causes differences in the true stress-strain along the contraction neck prior to fracture as well. The aim of the paper is to find correlation between microhardness as brief inspection parameters and extension of martensitic transformation. The total equivalent plastic strain extend diagram obtained by numerical simulation of bending was compared with tensile true stress-strain diagram. Results show very good correlation between hardness, true strain and martesite content. Therefore, one can conclude that by hardness measurement, it is possible to measure the level of equivalent plastic strain until ultimate tensile stress as a linear correlation between hardness, true strain and martesite content.

  16. Microstructure and Texture Evolutions in AISI 1050 Steel by Flow Forming

    Energy Technology Data Exchange (ETDEWEB)

    Bedekar, Vikram [Timken Technology Center, Canton, OH; Pauskar, Praveen [Ohio State University, Columbus; Shivpuri, Rajiv [Ohio State University, Columbus; Howe, Jane Y [ORNL

    2014-01-01

    Hot rolled and annealed AISI 1050 steel cylindrical coupons were flow formed at different levels of deformation (66% and 90% wall thickness reduction). TEM studies revealed development of ultra fine (sub) grain cell structure due to severe plastic deformation. The transverse subgrain size changed from 10 m (beginning) to 300nm (66% deformation) to 40nm (90% deformation). EBSD study revealed decreased recrystallization fraction at 90% deformation compared with 66% deformation due to orientation pinning from preferred orientation along {002} planes. No evidence of dislocation pinning or cracking was observed on any samples. The aim of the present work is to study the deformation behaviour and microstructural evolution during conventional flow forming process. The study also sheds light on the strengthening behaviour and structural changes during severe straining.

  17. Optimization of Process Parameters in Turning of AISI 8620 Steel Using Taguchi and Grey Taguchi Analysis

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Sharma

    2014-03-01

    Full Text Available The aim of this research is to investigate the optimization of cutting parameters (cutting speed, feed rate and depth of cut for surface roughness and metal removal rate in turning of AISI 8620 steel using coated carbide insert. Experiments have been carried out based on Taguchi L9 standard orthogonal array design with three process parameters namely cutting speed, feed rate and depth of cut for surface roughness and metal removal rate. The objective function has been chosen in relation to surface roughness and metal removal rate for quality target. Optimal parameters contribution of the CNC turning operation was obtained via grey relational analysis. The analysis of variance is applied to identify the most significant factor. Experiment with the optimized parameter setting, which has been obtained from the analysis, are giving to validate the results.

  18. Surface characteristics analysis of dry EDMed AISI D2 steel using modified tool design

    Energy Technology Data Exchange (ETDEWEB)

    Pragadish, N.; Kumar, M. Pradeep [Anna University, Chennai (China)

    2015-04-15

    A modified tool design is proposed which helps in drilling holes without any central core, and also enables the effective removal of the debris particles. Experiments were conducted on AISI D2 Steel using copper electrode as tool in both conventional EDM and dry EDM processes and the performance of both processes is compared. Experiments were designed using Taguchi's L27 orthogonal array. Discharge current (I), gap voltage (V), pulse on time (T{sub ON}), gas pressure (P) and tool rotational speed (N) were chosen as the various input parameters, and their effect on the material removal rate (MRR), surface roughness (SR), surface morphology, microstructure and elemental composition of the machined surface is analyzed. The experimental results show better surface characteristics in the surface machined under dry EDM process.

  19. ANALYSIS OF CUTTING FORCE AND CHIP MORPHOLOGY DURING HARD TURNING OF AISI D2 STEEL

    Directory of Open Access Journals (Sweden)

    X. M. ANTHONY

    2015-03-01

    Full Text Available In this research work AISI D2 tool steel at a hardness of 55 HRC is being used for experimental investigation. Cutting speed, feed rate and depth of cut are the cutting parameters considered for the experimentation along with tool geometry namely, nose radius, clearance angle and rake angle. Three different cutting tool materials are used for experimentation namely multicoated carbide, cermet and ceramic inserts. The cutting force generated during the machining process is being measured using Kistler dynamometer and recorded for further evaluation. The chips produced during the machining process for every experimental trail is also collected for understanding the chip morphology. Based on the experimental data collected Analysis of Variance (ANOVA was conducted to understand the influence of all cutting parameters and tool geometry on cutting force.

  20. Tensile and Impact Properties of Shielded Metal Arc Welded AISI 409M Ferritic Stainless Steel Joints

    Institute of Scientific and Technical Information of China (English)

    K.Shanmugam; A.K.Lakshminarayanan; V.Balasubramanian

    2009-01-01

    The present study is concerned with the effect of filler metals such as austenitic stainless steel, ferritic stainless steel and duplex stainless steel on tensile and impact properties of the ferritic stainless steel conforming to AISI 409M grade. Rolled plates of 4 mm thickness were used as the base material for preparing single pass butt welded joints. Tensile and impact properties, microhardness, microstructure and fracture surface morphology of the joints fabricated by austenitic stainless steel, ferritic stainless steel and duplex stainless steel filler metals were evaluated and the results were reported. From this investigation, it is found that the joints fabricated by duplex stainless steel filler metal showed higher tensile strength and hardness compared to the joints fabricated by austenitic and ferritic stainless steel filler metals. Joints fabricated by austenitic stainless steel filler metal exhibited higher ductility and impact toughness compared with the joints fabricated by ferritic stainless steel and duplex stainless steel filler metals.

  1. The Investigation of Surface Roughness on AISI 1040 Steel with Dry Turning

    Directory of Open Access Journals (Sweden)

    Nergizhan Kavak

    2012-12-01

    Full Text Available In this study, the effect of cutting speed and feed rate on the surface roughness was investigated experimentaly in the machining of AISI 1040 steel being mostly used in industry. Experiments was done by dry turning with uncoated cementite carbite cutting tools at different speeds (46. 91 ve 128 m/dk and feed rates (0.16, 0.22 ve 0.28 mm/dev while cutting depth stays stable at 2 mm. It was observed that workpiece surface quality get worse with the increase of feed rate or decrease of cutting speed. As a result of this work, it was seen that 128 m/min cutting speed and 0.16 mm/rev feed rate for the 2 mm cutting depth are the optimum cutting conditions from the point of surface quality.

  2. Effect of the powder particle size on the wear behavior of boronized AISI 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Guenen, Ali [Mustafa Kemal Univ., Hatay (Turkey). Dept. of Metallurgy and Material Engineering; Kuecuek, Yilmaz; Oege, Mecit; Goek, M. Sabri [Bartin Univ. (Turkey). Dept. of Mechanical Engineering; Er, Yusuf [Firat Univ., Elazig (Turkey); Cay, V. Veli [Dicle Univ., Diyarbakir (Turkey). Civil Aviation Higher School

    2015-06-01

    In this study, the AISI 304 steel specimens were boronized with nanoboron of the size of 10 50 nm and commercial Ekabor 3 powders (<1400 μm) at 950 C to 1000 C for 2 h and 4 h. Boronized steel specimens were characterized via SEM, microhardness and XRD analyses. Abrasive wear behavior of the specimens, boronized at different temperatures and treatment durations, were examined. The fixed ball micro-abrasion tests were carried out using the abrasive slurry, prepared with different SiC powder particle sizes on the boronized specimens at different rotational speeds. The specimens boronized with nanoboron powders exhibited a higher hardness and abrasive wear resistance than the samples boronized with the Ekabor 3 powders.

  3. Evaluation of the corrosion resistance of AISI 316 stainless steel filters

    Directory of Open Access Journals (Sweden)

    Luzinete Pereira Barbosa

    2005-06-01

    Full Text Available In this investigation, the corrosion resistance of AISI 316 SS filters prepared with powders in the size ranges 74-44 µm and 210-105 µm and compacted with pressures of 300 MPa and 400 MPa has been evaluated in naturally aerated 0.5 M H2SO4 solution at 25 °C. Weight loss of filters manufactured with compacting pressure of 400 MPa were significantly higher than that of filters compacted at 300 MPa. The filter compacted at 400 MPa had higher carbon and nitrogen contents compared to those compacted at 300 MPa. The former also had chromium rich precipitates and oxides in the grain boundaries. The pores in filters compacted at 400 MPa were smaller than in filters compacted at 300 MPa. Smaller pores favor the formation of concentration cells and consequently, increased crevice corrosion.

  4. Effect of Hydrogen and Strain-Induced Martensite on Mechanical Properties of AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Sang Hwan Bak

    2016-07-01

    Full Text Available Plastic deformation and strain-induced martensite (SIM, α′ transformation in metastable austenitic AISI 304 stainless steel were investigated through room temperature tensile tests at strain rates ranging from 2 × 10−6 to 2 × 10−2/s. The amount of SIM was measured on the fractured tensile specimens using a feritscope and magnetic force microscope. Elongation to fracture, tensile strength, hardness, and the amount of SIM increased with decreasing the strain rate. The strain-rate dependence of RT tensile properties was observed to be related to the amount of SIM. Specifically, SIM formed during tensile tests was beneficial in increasing the elongation to fracture, hardness, and tensile strength. Hydrogen suppressed the SIM formation, leading to hydrogen softening and localized brittle fracture.

  5. Effect of Carbon and Nitrogen Content on Deformation and Fracture of AISI 304 Austenitic Stainless Steel

    Directory of Open Access Journals (Sweden)

    C. Menapace

    2008-04-01

    Full Text Available The effect of small differences in the content of carbon and nitrogen on the room temperature tensile deformation and fracture behaviour of an AISI 304 stainless steel was studied. In the steel containing the lower amount of carbon and nitrogen, a higher amount of strain induced alfa’ martensite is formed, which increases strain hardening rate and both uniform and total elongation at fracture. The presence of large martensitic areas in the cross section causes strain localization at the austenite/martensite interface, which promotes the nucleation of cracks and their propagation along the interface. This results in a decrease of Ultimate Tensile Strength. Strain induced transformation slightly reduces strain rate sensitivity, as well.

  6. Effect of Plasma Nitriding Temperatures on Characteristics of Aisi 201 Austenitic Stainless Steel

    Science.gov (United States)

    Gao, Yuxin; Zheng, Shaomei

    2016-10-01

    Samples of AISI 201 austenitic stainless steel were produced by plasma nitriding at 350∘C, 390∘C, 420∘C, 450∘C and 480∘C for 5h. Systematic characterization of the nitrided layer was carried out in terms of micrograph observations, phase identification, chemical composition depth profiling, surface microhardness measurements and electrochemical corrosion tests. The results show that the surface hardness and the layer thickness increased with increasing temperature. XRD indicated that a single S-phase layer was formed during low temperature (≤420∘C), while Cr2N or CrN phase was formed besides S-phase when nitrided at 450∘C and 480∘C. The specimen treated at 390∘C presents a much enhanced corrosion resistance compared to the untreated substrate. The corrosion resistance deteriorated for samples treated above 450∘C due to the formation of chromium nitrides.

  7. Studies on corrosion protection of laser hybrid welded AISI 316 by laser remelting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Ambat, Rajan; Rasmussen, A.J.

    2005-01-01

    Unlike in autogenous laser welding, hybrid laser welding of stainless steel could introduce grain boundary carbides due to low cooling rates. Formation of grain boundary carbides leads to reduced corrosion properties. Studies have initially been carried out on hybrid laser welding and subsequent...... laser surface melting on microstructure and corrosion behaviour of AISI 316L welds. Welding and laser treatment parameters were varied. General corrosion behaviour of the weld and laser treated surface was characterised using a gel visualization test. The local electrochemistry of the weld and laser...... treated surface was investigated using a novel micro electrochemical technique with a tip resolution of ~1 mm. Results show that hybrid laser welding of 316L has increased corrosion susceptibility probably as a result of grain boundary carbide formation. However a suitable post laser treatment could...

  8. Fatigue assessment by energy approach during tensile tests on AISI 304 steel

    Directory of Open Access Journals (Sweden)

    A. Risitano

    2017-01-01

    Full Text Available Estimation of the fatigue limit for steel ductile materials using non-destructive methods is a topic of great interest to researchers today. In recent years, the method adopted has implemented infrared sensors to detect the surface temperature and correlate it with the fatigue limit. In previous paper, a new energy approach was proposed to investigate the fatigue limit during tensile test. The numerical procedure proposed by Chrysochoos is adopted to clean infrared images and applied to analyse the surface heat sources during tensile test. AISI 304 specimens with rectangular cross-sections are tested. Moreover fatigue tests at increasing loads were carried out on steel by a stepwise succession, applied to the same specimen, for applying the thermographic method. The predictions of the fatigue limit, obtained by the analysis of the energy evolution during the static tests, were compared with the predictions obtained applying the thermographic method during fatigue tests.

  9. Determining Ms temperature on a AISI D2 cold work tool steel using magnetic Barkhausen noise

    Energy Technology Data Exchange (ETDEWEB)

    Huallpa, Edgar Apaza, E-mail: gared1@gmail.com [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil); Sánchez, J. Capó, E-mail: jcapo@usp.br [Departamento de Física, Facultad de Ciencias Naturales, Universidad de Oriente, Av. Patricio Lumumba s/n 90500, Santiago de Cuba (Cuba); Padovese, L.R., E-mail: lrpadove@usp.br [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil); Goldenstein, Hélio, E-mail: hgoldens@usp.br [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil)

    2013-11-15

    Highlights: ► MBN was used to follow the martensite transformation in a tool steel. ► The results were compared with resistivity experiments. ► The Ms was estimated with Andrews equation coupled to ThermoCalc calculations. The experimental results showed good agreement. -- Abstract: The use of Magnetic Barkhausen Noise (MBN) as a experimental method for measuring the martensite start (Ms) temperature was explored, using as model system a cold-work tool steel (AISI D2) austenitized at a very high temperature (1473 K), so as to transform in sub-zero temperatures. The progress of the transformation was also followed with electrical resistance measurements, optical microscopy and scanning electron microscopy. Both MBN and resistivity measurements showed a change near 230 K during cooling, corresponding to the Ms temperature, as compared with 245 K, estimated with Andrews empirical equation applied to the austenite composition calculated using ThermoCalc.

  10. Dynamic fracture toughness and Charpy impact properties of an AISI 403 martensitic stainless steel

    Science.gov (United States)

    Sreenivasan, P. R.; Ray, S. K.; Mannan, S. L.; Rodriguez, P.

    1996-04-01

    Dynamic fracture toughness and Charpy impact properties of a normalised and tempered AISI 403 martensitic stainless steel obtained from instrumented impact tests are presented. Procedures for estimating dynamic fracture toughness ( KId) from the load-time traces obtained in instrumented tests of unprecracked Charpy V-notch (CVN) specimens are considered. The estimated KId values show reasonable agreement with those obtained from instrumented drop-weight and precracked Charpy tests. Also, except in the upper transition and uppershelf regions, the ASME KIR curve is generally conservative (i.e. gives lower KId values) when compared to the above KId estimates. The conservatism of the ASME KIR at the upper transition and uppershelf temperatures needs verification/validation. The lowest KId values estimated at the lower shelf temperatures for the above steel, namely, 33-42 MPa√m are in good agreement with the reported values of 35-50 MPa√m for the same steel in the literature.

  11. Influence of Laser Peening on Phase Transformation and Corrosion Resistance of AISI 321 steel

    Science.gov (United States)

    Karthik, D.; Swaroop, S.

    2016-07-01

    The objective of this study is to investigate the influence of laser peening without coating (LPwC) on austenitic to martensitic (γ → α') phase transformation and corrosion behavior of austenitic stainless steel AISI 321 in 3.5% NaCl environment. Results indicate that LPwC induces a large compressive residual stresses of nearly -854 MPa and γ → α' phase transformation of about 18% (volume fraction). Microstructures of peened surface confirmed the γ → α' phase transformation and showed no grain refinement. Hardness increased slightly with a case depth of 900 μm. Despite the smaller surface roughness introduced, corrosion resistance improved after peening due to compressive residual stresses.

  12. Acoustic Emission Methodology to Evaluate the Fracture Toughness in Heat Treated AISI D2 Tool Steel

    Science.gov (United States)

    Mostafavi, Sajad; Fotouhi, Mohamad; Motasemi, Abed; Ahmadi, Mehdi; Sindi, Cevat Teymuri

    2012-10-01

    In this article, fracture toughness behavior of tool steel was investigated using Acoustic Emission (AE) monitoring. Fracture toughness ( K IC) values of a specific tool steel was determined by applying various approaches based on conventional AE parameters, such as Acoustic Emission Cumulative Count (AECC), Acoustic Emission Energy Rate (AEER), and the combination of mechanical characteristics and AE information called sentry function. The critical fracture toughness values during crack propagation were achieved by means of relationship between the integral of the sentry function and cumulative fracture toughness (KICUM). Specimens were selected from AISI D2 cold-work tool steel and were heat treated at four different tempering conditions (300, 450, 525, and 575 °C). The results achieved through AE approaches were then compared with a methodology proposed by compact specimen testing according to ASTM standard E399. It was concluded that AE information was an efficient method to investigate fracture characteristics.

  13. Studies on corrosion protection of laser hybrid welded AISI 316 by laser remelting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Ambat, Rajan; Rasmussen, A.J.

    2005-01-01

    Unlike in autogenous laser welding, hybrid laser welding of stainless steel could introduce grain boundary carbides due to low cooling rates. Formation of grain boundary carbides leads to reduced corrosion properties. Studies have initially been carried out on hybrid laser welding and subsequent...... laser surface melting on microstructure and corrosion behaviour of AISI 316L welds. Welding and laser treatment parameters were varied. General corrosion behaviour of the weld and laser treated surface was characterised using a gel visualization test. The local electrochemistry of the weld and laser...... treated surface was investigated using a novel micro electrochemical technique with a tip resolution of ~1 mm. Results show that hybrid laser welding of 316L has increased corrosion susceptibility probably as a result of grain boundary carbide formation. However a suitable post laser treatment could...

  14. Electrochemical behaviour of iron and AISI 304 stainless steel in simulated acid rain solution

    Energy Technology Data Exchange (ETDEWEB)

    Pilic, Zora; Martinovic, Ivana [Mostar Univ. (Bosnia and Herzegovina). Dept. of Chemistry

    2016-10-15

    The growth mechanism and properties of the oxide films on iron and AISI 304 stainless steel were studied in simulated acid rain (pH 4.5) by means of electrochemical techniques and atomic absorption spectrometry. The layer-pore resistance model was applied to explain a potentiodynamic formation of surface oxides. It was found that the growth of the oxide film on iron takes place by the low-field migration mechanism, while that on the stainless steel takes place by the high-field mechanism. Kinetic parameters were determined. Impedance measurements revealed that Fe surface film has no protective properties at the open circuit potential, while the resistance of stainless steel oxide film is very high. The concentration of the metallic ions released into solution and measured by atomic absorption spectroscopy was in accordance with the results obtained from the electrochemical techniques.

  15. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants

    OpenAIRE

    Camargos, Germana de Villa; SOTTO-MAIOR,Bruno Salles; Silva,Wander José da; Priscilla Cardoso LAZARI; Del Bel Cury, Altair Antoninha

    2016-01-01

    Abstract This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created with different types of prosthetic abutment (UCLA or conical), implant connection (external hexagon, EH or internal hexagon, IH), and occlusal loading (axial or oblique), for both i...

  16. On The Enhancement of Wear Resistance of Hardened Carbon Tool Steel (AISI 1095) With Cryogenic Quenching

    Institute of Scientific and Technical Information of China (English)

    V.Soundararajan; N.Alagurmurthi; K.Palaniradja

    2004-01-01

    Many experimental investigations reveal that it is very difficult to have a completely martensitic structure by any hardening process. Some amount of austenite is generally present in the hardened steel. This austenite existing along with martensite is normally referred as the retained austenite. The presence of retained austenite greatly reduces the mechanical properties and such steels do not develop maximum hardness even after cooling at rates higher than the critical cooling rates.Strength can be improved in hardened steels containing retained austenite by a process known as cryogenic quenching.Untransformed austenite is converted into martensite by this treatment. This conversion of retained austenite into martensite results in increased hardness, wear resistance and dimensional stability of steel. Wear can be defined as the progressive loss of materials from the operating surface of a body occurring as a result of relative motion at the surface. Hardness, load,speed, surface roughness, temperature are the major factors which influences wear. Many studies on wear indicate that increasing hardness decreases the wear of a material. With this in mind, to study the surface wear on a surface modified(Cryogenic treated) steel material an attempt has been made in this paper. In this study as a Part -I Hardening was carried out on carbon tool steel (AISI 1095) of different L/D ratio with conventional quenchants like purified water, aqueous solution and Hot mineral oil. As a Part -Ⅱ hardening was followed by quenching was carried out as said in Part- I and the hardened specimen were quenched in liquid Nitrogen which is at sub zero condition. The specimens were tested for its microstructure, hardness and wear loss. The results were compared and analyzed. The alloying elements increases the content of retained austenite hence the material used was AISI1095 (Carbon 0.9%, Si 0.2%, Mn0.4% and the rest Iron)

  17. Investigating the correlation between some of the properties of plasma nitrided AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    M. Olzon-Dionysio

    2013-01-01

    Full Text Available When AISI 316L stainless steels are submitted to the nitriding process at temperatures lower than 450 °C, a high nitrogen content expanded austenite phase is formed, which shows higher hardness and higher pitting corrosion resistance compared to the untreated material. As a result, this material becomes adequate for biomedical application. The conditions of the nitriding technique, such as gas mixture, pressure, time and temperature, play an important role in some properties of the modified layer, including: thickness, hardness and N concentration along the layer. This paper explores a set of six samples of AISI 316L, nitrided at different times and temperatures, whose properties show important differences. The aim of this research is to investigate the correlation between the nitrided layer thickness (in the range of 0.77 to 11 µm with both X-ray patterns characteristics and hardness measurements, which used two distinct loads. The results of this study show that: whereas the 3.6 gf load was suitable to measure the real hardness for four of the nitrided layers showing thickness ≥ 2.9 µm, the 50 gf load measured a substrate contribution, probably even for the highest thickness, 11 µm. Moreover, analyzing different reflections of the X-ray patterns showed evidence of the clear consistency between the X-Ray depths and the nitrided layer thicknesses: if the layer thickness is lower than the penetration depth of X-rays, two phases (austenite and expanded substrate are present. If the layer thickness is higher, only the austenite is observed. Finally, concerning the citotoxicity property, all the samples, nitrided or not, were approved in the test for biocompatibility, indicating their potential use for biomedical applications.

  18. Erosion and corrosion resistance of laser cladded AISI 420 stainless steel reinforced with VC

    Science.gov (United States)

    Zhang, Zhe; Yu, Ting; Kovacevic, Radovan

    2017-07-01

    Metal Matrix Composites (MMC) fabricated by the laser cladding process have been widely applied as protective coatings in industries to improve the wear, erosion, and corrosion resistance of components and prolong their service life. In this study, the AISI 420/VC metal matrix composites with different weight percentage (0 wt.%-40 wt.%) of Vanadium Carbide (VC) were fabricated on a mild steel A36 by a high power direct diode laser. An induction heater was used to preheat the substrate in order to avoid cracks during the cladding process. The effect of carbide content on the microstructure, elements distribution, phases, and microhardness was investigated in detail. The erosion resistance of the coatings was tested by using the abrasive waterjet (AWJ) cutting machine. The corrosion resistance of the coatings was studied utilizing potentiodynamic polarization. The results showed that the surface roughness and crack susceptibility of the laser cladded layer were increased with the increase in VC fraction. The volume fraction of the precipitated carbides was increased with the increase in the VC content. The phases of the coating without VC consisted of martensite and austenite. New phases such as precipitated VC, V8C7, M7C3, and M23C6 were formed when the primary VC was added. The microhardness of the clads was increased with the increase in VC. The erosion resistance of the cladded layer was improved after the introduction of VC. The erosion resistance was increased with the increase in the VC content. No obvious improvement of erosion resistance was observed when the VC fraction was above 30 wt.%. The corrosion resistance of the clads was decreased with the increase in the VC content, demonstrating the negative effect of VC on the corrosion resistance of AISI 420 stainless steel

  19. Experimental and numerical study on plasma nitriding of AISI P20 mold steel

    Science.gov (United States)

    Nayebpashaee, N.; Vafaeenezhad, H.; Kheirandish, Sh.; Soltanieh, M.

    2016-09-01

    In this study, plasma nitriding was used to fabricate a hard protective layer on AISI P20 steel, at three process temperatures (450°C, 500°C, and 550°C) and over a range of time periods (2.5, 5, 7.5, and 10 h), and at a fixed gas N2:H2 ratio of 75vol%:25vol%. The morphology of samples was studied using optical microscopy and scanning electron microscopy, and the formed phase of each sample was determined by X-ray diffraction. The elemental depth profile was measured by energy dispersive X-ray spectroscopy, wavelength dispersive spectroscopy, and glow dispersive spectroscopy. The hardness profile of the samples was identified, and the microhardness profile from the surface to the sample center was recorded. The results show that ɛ-nitride is the dominant species after carrying out plasma nitriding in all strategies and that the plasma nitriding process improves the hardness up to more than three times. It is found that as the time and temperature of the process increase, the hardness and hardness depth of the diffusion zone considerably increase. Furthermore, artificial neural networks were used to predict the effects of operational parameters on the mechanical properties of plastic mold steel. The plasma temperature, running time of imposition, and target distance to the sample surface were all used as network inputs; Vickers hardness measurements were given as the output of the model. The model accurately reproduced the experimental outcomes under different operational conditions; therefore, it can be used in the effective simulation of the plasma nitriding process in AISI P20 steel.

  20. Tribological Properties of Nanometric Atomic Layer Depositions Applied on AISI 420 Stainless Steel

    Directory of Open Access Journals (Sweden)

    E. Marin

    2013-09-01

    Full Text Available Atomic Layer Deposition ( ALD is a modern technique that Allows to deposit nanometric, conformal coatings on almost any kind of substrates, from plastics to ceramic, metals or even composites. ALD coatings are not dependent on the morphology of the substrate and are only regulated by the composition of the precursors, the chamber temperature and the number of cycles. In this work, mono- and bi -layer nanometric, protective low-temperature ALD Coatings, based on Al2O3 and TiO2 were applied on AISI 420 Stainless Steel in orderto enhance its relatively low corrosion resistance in chloride containing environments. Tribological testing were also performed on the ALD coated AISI 420 in order to evaluate the wear and scratch resistance of these nanometric layers and thus evaluate their durability. Scratch tests were performed using a standard Rockwell C indenter, under a variable load condition, in order to evaluate the critical loading condition for each coating. Wear testing were performed using a stainless steel counterpart, in ball-on-discconfiguration, in order to measure the friction coefficient and wear to confront the resistance. All scratch tests scars and wear tracks were then observed by means of Scanning Electron Microscopy (SEM in order to understand the wear mechanisms that occurred on the sample surfaces. Corrosion testing, performed under immersion in 0.2 M NaCl solutions, clearly showed that the ALD coatings have a strong effect in protecting the Stainless Steel Substrate against corrosion, reducing the corrosion current density by two orders of magnitude.Tribological The preliminary results showed that ALD depositions obtained at low Temperatures have a brittle behavior caused by the amorphous nature of their structure, and thus undergo delamination phenomena during Scratch Testing at relatively low applied loads. During ball-on-disc testing, the coatings were removed from the substrate, in particular for monolayer ALD configurations

  1. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  2. Decrease of Staphylococcal adhesion on surgical stainless steel after Si ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Braceras, Iñigo, E-mail: inigo.braceras@tecnalia.com [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Pacha-Olivenza, Miguel A. [CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); Calzado-Martín, Alicia [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Multigner, Marta [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vera, Carolina [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Broncano, Luis Labajos-; Gallardo-Moreno, Amparo M. [Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); González-Carrasco, José Luis [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vilaboa, Nuria [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); and others

    2014-08-15

    Highlights: • Si ion implantation of AISI 316LVM medical grade alloy might reduce bacterial adhesion and colonization. • Si ion implantation does not impair the attachment, viability and matrix maturation of human mesenchymal stem cells. • Nano-topography and surface chemistry changes account for the Si ion implantation induced effects. - Abstract: 316LVM austenitic stainless steel is often the material of choice on temporal musculoskeletal implants and surgical tools as it combines good mechanical properties and acceptable corrosion resistance to the physiologic media, being additionally relatively inexpensive. This study has aimed at improving the resistance to bacterial colonization of this surgical stainless steel, without compromising its biocompatibility and resistance. To achieve this aim, the effect of Si ion implantation on 316LVM has been studied. First, the effect of the ion implantation parameters (50 keV; fluence: 2.5–5 × 10{sup 16} ions/cm{sup 2}; angle of incidence: 45–90°) has been assessed in terms of depth profiling of chemical composition by XPS and nano-topography evaluation by AFM. The in vitro biocompatibility of the alloy has been evaluated with human mesenchymal stem cells. Finally, bacterial adhesion of Staphylococcus epidermidis and Staphylococcus aureus on these surfaces has been assessed. Reduction of bacterial adhesion on Si implanted 316LVM is dependent on the implantation conditions as well as the features of the bacterial strains, offering a promising implantable biomaterial in terms of biocompatibility, mechanical properties and resistance to bacterial colonization. The effects of surface composition and nano-topography on bacterial adhesion, directly related to ion implantation conditions, are also discussed.

  3. Hernia Surgical Mesh Implants

    Science.gov (United States)

    ... Prosthetics Hernia Surgical Mesh Implants Hernia Surgical Mesh Implants Share Tweet Linkedin Pin it More sharing options ... majority of tissue used to produce these mesh implants are from a pig (porcine) or cow (bovine) ...

  4. Urogynecologic Surgical Mesh Implants

    Science.gov (United States)

    ... Prosthetics Urogynecologic Surgical Mesh Implants Urogynecologic Surgical Mesh Implants Share Tweet Linkedin Pin it More sharing options ... majority of tissue used to produce these mesh implants are from a pig (porcine) or cow (bovine). ...

  5. Degradation of implant materials

    CERN Document Server

    Eliaz, Noam

    2012-01-01

    This book surveys the degradation of implant materials, reviewing in detail such failure mechanisms as corrosion, fatigue and wear, along with monitoring techniques. Surveys common implant biomaterials, as well as procedures for implant retrieval and analysis.

  6. High temperature cyclic oxidation of AISI 310 steel in atmospheres with variable oxidation content; Oxidacion ciclica de un acero refractario AISI 310 a alta temperatura en atmosferas con centenidos de oxigeno variables

    Energy Technology Data Exchange (ETDEWEB)

    Higuera-Hidalgo, V.; Belzunce-Varela, F. J.; Riba-Lopez, J.

    2005-07-01

    High temperature oxidation test of an AISI 310 stainless steel was performed in two different environments: in an standard atmosphere (21% oxygen) at 704, 800, 884 and 1,000 degree centigree and in the typical environment of a gas turbine and vapor generator of a combined-cycle electric generation unit (10%oxygen) at 800 and 1,000 degree centigree. The oxidation kinetics was determined by means of the measurements of the weight gain per unit surface of the specimen and also determining the thickness of the oxide layer. Comparable results have been obtained using both methodologies and the effect of the oxygen content along with the other experimental differences were determined observing the oxidation kinetics in both environments. The cyclic oxidation of AISI 310 deteriorates at temperatures higher than 1,000 degree centigree. (Author) 9 refs.

  7. Prevalence of peri-implantitis in patients with implant-supported fixed prostheses.

    Science.gov (United States)

    Schuldt Filho, Guenther; Dalago, Haline Renata; Oliveira de Souza, João Gustavo; Stanley, Kyle; Jovanovic, Sascha; Bianchini, Marco Aurélio

    2014-01-01

    The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P implantitis (P implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.

  8. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants.

    Science.gov (United States)

    Camargos, Germana de Villa; Sotto-Maior, Bruno Salles; Silva, Wander José da; Lazari, Priscilla Cardoso; Del Bel Cury, Altair Antoninha

    2016-05-31

    This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created with different types of prosthetic abutment (UCLA or conical), implant connection (external hexagon, EH or internal hexagon, IH), and occlusal loading (axial or oblique), for both immediately and delayed loaded implants. Analysis of variance at 95%CI was used to evaluate the peak maximum principal stress and strain in bone after applying a 100 N occlusal load. The results showed that the type of prosthetic abutment influences bone stress/strain in only immediately loaded implants. Attachment of conical abutments to IH implants exhibited the best biomechanical behavior, with optimal distribution and dissipation of the load in peri-implant bone.

  9. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants

    Directory of Open Access Journals (Sweden)

    Germana de Villa CAMARGOS

    2016-01-01

    Full Text Available Abstract This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created with different types of prosthetic abutment (UCLA or conical, implant connection (external hexagon, EH or internal hexagon, IH, and occlusal loading (axial or oblique, for both immediately and delayed loaded implants. Analysis of variance at 95%CI was used to evaluate the peak maximum principal stress and strain in bone after applying a 100 N occlusal load. The results showed that the type of prosthetic abutment influences bone stress/strain in only immediately loaded implants. Attachment of conical abutments to IH implants exhibited the best biomechanical behavior, with optimal distribution and dissipation of the load in peri-implant bone.

  10. Comportamiento del desgaste del flanco en el torneado en seco de alta velocidad del acero AISI 316L//Flank wear behavior in the dry high‐speed turning of AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Yoandrys Morales-Tamayo

    2013-09-01

    Full Text Available El presente estudio experimental se centra en investigar los efectos de los parámetros corte en el desgaste de flanco con dos insertos recubiertos durante el torneado de acabado en seco a altas velocidades del acero inoxidable AISI 316L. Los efectos de los parámetros de corte fueron determinados utilizando un análisis de varianza y de regresión simple. Como principal resultado se obtuvo el efectosignificativo del avance y del tiempo de maquinado en el desgaste del flanco. El inserto de tres capas no sobrepasó el criterio de fin de vida del desgaste, mientras que el inserto de una capa sufrió un desgaste catastrófico para la mayor velocidad de corte. El desgaste del flanco tuvo mejor comportamiento para el avance de 0,08 mm/rev en todas las velocidades empleadas en este estudio.Palabras claves: torneado de alta velocidad, desgaste de flanco, acero inoxidable AISI 316L, estudio experimental, análisis de varianza y regresión.______________________________________________________________________________AbstractThe current experimental study is focused on investigating the effects of cutting parameters on flank wear in two coated carbide inserts during dry high speed finish turning of AISI 316L stainless steel. The effects of cutting parameters were determinate using analysis of variance and simple regression. As a main resulta significant effect of cutting feed and the machining time on flank wear was found. The three coating layers insert did not exceed the criterion of end of life of wear while the insert with one layer suffered a catastrophic wear at the highest cutting speed. The flank wear showed the best performance for the cuttingfeed of 0,08 mm/rev at all the speeds used in the study.Key words: high speed turning; flank wear; AISI 316L stainless steel, experimental study; analysis of variance and regression.

  11. Study of corrosion resistance of AISI 444 ferritic stainless steel for application as a biomaterial; Estudo da resistencia a corrosao do aco inoxidavel ferritico AISI 444 para aplicacao como biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Rogerio Albuquerque

    2014-09-01

    Ferritic stainless steels are ferromagnetic materials. This property does not allow their use in orthopedic prosthesis. Nevertheless, in some specific applications, this characteristic is very useful, such as, for fixing dental and facial prostheses by using magnetic attachments. In this study, the corrosion resistance and cytotoxicity of the AISI 444 ferritic stainless steel, with low nickel content, extra-low interstitial levels (C and N) and Ti and Nb stabilizers, were investigated for magnetic dental attachments application. The ISO 5832-1 (ASTM F-139) austenitic stainless steel and a commercial universal keeper for dental attachment (Neo-magnet System) were evaluated for comparison reasons. The first stainless steel is the most used metallic material for prostheses, and the second one, is a ferromagnetic keeper for dental prostheses (NeoM). In vitro cytotoxicity analysis was performed by the red neutral incorporation method. The results showed that the AISI 444 stainless steel is non cytotoxic. The corrosion resistance was studied by anodic polarization methods and electrochemical impedance spectroscopy (EIS), in a saline phosphate buffered solution (PBS) at 37 °C. The electronic properties of the passive film formed on AISI 444 SS were evaluated by the Mott-Schottky approach. All tested materials showed passivity in the PBS medium and the passive oxide film presented a duplex nature. The highest susceptibility to pitting corrosion was associated to the NeoM SS. This steel was also associated to the highest dopant concentration. The comparatively low levels of chromium (nearly 12.5%) and molybdenum (0.3%) of NeoM relatively to the other studied stainless steels are the probable cause of its lower corrosion resistance. The NeoM chemical composition does not match that of the SUS444 standards. The AISI 444 SS pitting resistance was equivalent to the ISO 5832-1 pointing out that it is a potential candidate for replacement of commercial ferromagnetic alloys used

  12. Evaluación del comportamiento a fatiga de una unión soldada a tope de acero AISI 1015//Evaluation of the fatigue behaviour of a butt welded joint of AISI 1015 steel

    Directory of Open Access Journals (Sweden)

    Pavel Michel Almaguer‐Zaldivar

    2015-01-01

    Full Text Available Las uniones soldadas son un componente importante de una estructura, por lo que siempre es necesario conocer la respuesta de las mismas sometidas a cargas cíclicas. El objetivo de este trabajo es obtener la curva S-N de una unión soldada a tope de acero AISI 1015 y electrodo E6013 como material de aporte. Los ensayos a fatiga se realizaron de acuerdo a la norma ASTM en una máquina universal MTS810. Se utilizaron probetas de sección rectangular. El ciclo de carga fueasimétrico a tracción, con un coeficiente de asimetría de 0,1. Se obtuvo que la unión estudiada tiene un límite de resistencia a la fatiga de 178 MPa, a un punto de corte de 2 039 093 ciclos.Palabras claves: unión soldada, fatiga, curva S-N, AISI 1015, electrodo E6013._______________________________________________________________________________AbstractWelded joints are an important component in structures, by this reason is necessary to know the behaviour of these elements under cyclic loads. The objective of this work is to obtain the S-N curve of the butt welded joint of AISI 1015 steel and electrode E6013 as the contribution material. Fatiguetest was realized within the ASTM standard in the MTS810 testing machine. Rectangular cross section specimens was used. Cyclic loads was asymmetric tensile and the asymmetry ratio used was 0,1. In this study was obtained the fatigue limit equal to 178 MPa, at the cut point of 2 039 093 cycles.Key words: welded joint, fatigue, S-N curve, AISI 1015 steel, electrode E6013.

  13. Determinación de tensiones por rayos x del acero AISI 1045 deformado por rodillo // Determination of stress for x‐ray of the steel AISI 1045 deformed for roller

    Directory of Open Access Journals (Sweden)

    Tomás Fernández‐Columbié

    2012-01-01

    Full Text Available El objetivo del trabajo es realizar el análisis de las tensiones a muestras de acero AISI 1045 endurecidasen frío por rodillo. Con empleo del método de Willianson–Hall se determinó las macro ymicrodeformaciones; la deformación reticular del parámetro de red; el tamaño de las cristalitas; losesfuerzos en la red cristalina y la reducción del tamaño promedio de los granos, lo que permitió establecerlos mecanismos de endurecimiento del acero AISI 1045, deformado por rodadura. Fueron medidos yanalizados diferentes puntos teniendo en cuenta los índices de Miller para la fase ferrítica del acero. Losmodelos lineales obtenidos, son estadísticamente significativos, que muestran una tendencia creciente delas propiedades mecánicas y metalúrgicas, según se incrementan las variables independientes delproceso de experimentación.Palabras claves: rodillo, rodadura, deformación plástica.__________________________________________________________________AbstractThe objective of the paper is to carry out the analysis from the tensions to steel samples AISI 1045hardened cold for roller. With employment of the method of Willianson-Hall was determined the macro andmicro deformations; the reticular deformation of the net parameter; the size of the crystallites; the efforts inthe crystalline net and the reduction of the size average of the grains, what allowed to establish themechanisms of hardening of the steel AISI 1045, deformed by rolling. They were measured and analyzeddifferent points keeping in mind the indexes of Miller for the phase ferrite of the steel. The obtained linealmodels, they are statistically significant that they show a growing tendency of the mechanical estates andmetallurgical, as the independent variables of the experimentation process are increased.Key words: roller, rolling, plastic deformation.

  14. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  15. Implant marketing: cost effective implant dentistry.

    Science.gov (United States)

    Wohrle, P S; Levin, R P

    1996-01-01

    The application of the KAL-Technique to the field of implant dentistry allows both patients and dental practices to benefit. It is an exciting advance that decreases frustration and stress in providing implant procedures and lowers overall costs. Professionals using the KAL-Technique report significant predictability in achieving passive framework fit. They are also lowering overall cost of implant cases, which increases the number of patients who can accept implant treatment. It has been well established that the more individuals in a practice that receive implants, the more referrals a practice will gain. This is because implant patients find tremendous advances in the quality of life, and do not hesitate to tell others who can take advantage of this opportunity. Implant dentistry is one of the fastest growing fields in dentistry today. While some other areas of dentistry begin to decline in volume and need, implant dentistry provides the opportunity to keep practices strong and to insure long-term success.

  16. Treatment of muscular contraction deformities with botulinum toxin type A after latissimus dorsi flap and sub-pectoral implant breast reconstruction.

    Science.gov (United States)

    Figus, Andrea; Mazzocchi, Marco; Dessy, Luca Andrea; Curinga, Giuseppe; Scuderi, Nicolò

    2009-07-01

    Unusual and probably underestimated complications following breast reconstruction with a latissimus dorsi (LD) flap and sub-pectoral implant are the LD muscle twitching and the breast contour deformities from pectoralis major (PM) muscle contraction. Surgical muscle denervation is usually indicated for these complications. Botulinum toxin A (BTX-A) infiltration has been described in reducing breast contour deformity in sub-pectoral implant after breast augmentation or reconstruction. Between January 2002 and April 2006, 71 consecutive patients underwent delayed unilateral breast reconstructions with LD flap and sub-pectoral implant after mastectomy. All patients reporting discomforting signs and symptoms from muscle contraction in the reconstructed breast were included in this prospective study. Thirteen patients (18.3%) were selected and treated with BTX-A percutaneous local injections. Signs and symptoms were evaluated, after 4, 8 and 12 months, by the patients and by a panel of three physicians not involved in the study, using a five-point scale. During the study period all patients reported a decrease or disappearance of the signs and symptoms. After 12 months, 11 patients received three BTX-A infiltrations, demonstrating considerable improvements compared to the pre-treatment status. Wilcoxon matched pairs rank sum test showed a statistical difference between pre-treatment and post-treatment scores after 14 days (P<0.01) and 12 months (P<0.001). Our experience shows that muscular contraction deformities after breast reconstruction with a LD flap plus implant are not uncommon complications. The use of BTX-A infiltrations is an effective, not surgical, low cost and low risk procedure to treat these complications. It is an easy procedure to be performed on an outpatient basis with a temporary effect but safely repeatable and reproducible; it avoids hospitalisation or further surgical procedures and demonstrates tolerable latency with satisfactory outcomes.

  17. LaCrO3 composite coatings for AISI 444 stainless steel solid oxide fuel cell interconnects

    Directory of Open Access Journals (Sweden)

    Wilson Acchar

    2012-12-01

    Full Text Available Doped lanthanum chromite-based ceramics are the most widely used interconnector material in solid fuel cells (SOFC since they exhibit significant electrical and thermal conductivity, substantial corrosion resistance and adequate mechanical strength at ambient and high temperatures. The disadvantage of this material is its high cost and poor ductility. The aim of this study is to determine the mechanical and oxidation behavior of a stainless steel (AISI 444 with a LaCrO3 deposition on its surface obtained through spray pyrolisis. Coated and pure AISI 444 materials were characterized by mechanical properties, oxidation behavior, X-ray diffraction and scanning electronic microscopy. Results indicated that the coated material displays better oxidation behavior in comparison to pure stainless steel, but no improvement in mechanical strength. Both materials indicate that deformation behavior depends on testing temperatures.

  18. Design of Quenching Process for Large-sized AISI P20 Steel Block Used as Plastic Die

    Institute of Scientific and Technical Information of China (English)

    Dongli SONG; Jianfeng GU; Jiansheng PAN; Xin YAO

    2006-01-01

    For large-sized AISI P20 steel block used as plastic die with a thickness of more than 200 mm, appropriate quenching processes are the key to obtain much thick hardened layer. In this paper, different quenching processes of AISI P20 steel block such as oil quenching, direct water quenching, water quenching with precooling and water quenching with pre-cooling and self-tempering were numerically investigated by computer simulation based on the detailed discussion on the mathematical models of quenching processes including partial differential equations of heat transfer, thermal physical properties, latent heat, heat transfer coefficient and calculation of phase transformation, The results show that the water quenching with pre-cooling and self-tempering process can not only effectively avoid quenching cracks, but also obtain deeper harden depth than oil quenching.

  19. Mathematical Modelling of Nitride Layer Growth of Low Temperature Gas and Plasma Nitriding of AISI 316L

    Directory of Open Access Journals (Sweden)

    Triwiyanto A.

    2014-07-01

    Full Text Available This paper present mathematical model which developed to predict the nitrided layer thickness (case depth of gas nitrided and plasma nitrided austenitic stainless steel according to Fick’s first law for pure iron by adapting and manipulating the Hosseini’s model to fit the diffusion mechanism where nitrided structure formed by nitrided AISI 316L austenitic stainless steel. The mathematical model later tested against various actual gas nitriding and plasma nitriding experimental results with varying nitriding temperature and nitriding duration to see whether the model managed to successfully predict the nitrided layer thickness. This model predicted the coexistence of ε-Fe2-3N and γ΄-Fe4N under the present nitriding process parameters. After the validation process, it is proven that the mathematical model managed to predict the nitrided layer growth of the gas nitrided and plasma nitrided of AISI 316L SS up to high degree of accuracy.

  20. OPTIMIZATION OF SURFACE ROUGHNESS OF AISI 304 AUSTENITIC STAINLESS STEEL IN DRY TURNING OPERATION USING TAGUCHI DESIGN METHOD

    Directory of Open Access Journals (Sweden)

    D. PHILIP SELVARAJ

    2010-09-01

    Full Text Available The present work is concentrated with the dry turning of AISI 304 Austenitic Stainless Steel (ASS. This paper presents the influence of cutting parameters like cutting speed, feed rate and depth of cut on the surface roughness of austenitic stainless steel during dry turning. A plan of experiments based on Taguchi’s technique has been used to acquire the data. An orthogonal array, the signal to noise (S/N ratio and the analysis of variance (ANOVA are employed to investigate the cutting characteristics of AISI 304 austenitic stainless steel bars using TiC and TiCN coated tungsten carbide cutting tool. Finally the confirmation tests that have been carried out to compare the predicted values with the experimental values confirm its effectiveness in the analysis of surface roughness.

  1. OPTIMIZATION OF SURFACE ROUGHNESS AND TOOL FLANK WEAR IN TURNING OF AISI 304 AUSTENITIC STAINLESS STEEL WITH CVD COATED TOOL

    Directory of Open Access Journals (Sweden)

    M. KALADHAR

    2013-04-01

    Full Text Available AISI 304 austenitic stainless steel is a popularly used grade in the various fields of manufacturing because of its high ductility, high durability and excellent corrosion resistance. High work hardening, low heat conductivity and high built up edge (BUE formation made this as difficult-to- machine material. Poor surface quality and rapid tool wear are the common problems encountered while machining it. In the present work, an attempt has been made to explore the influence of machining parameters on the performance measures, surface roughness and flank wear in turning of AISI 304 austenitic stainless steel with a two layer Chemical vapour deposition(CVD coated tool. In order to achieve this, Taguchi approach has been employed. The results revealed that the cutting speed most significantly, influences both surface roughness and flank wear. In addition to this the optimal setting of process parameters and optimal ranges of performance measures are predicted.

  2. EFFECTS OF CARBURIZING AND NITRIDING PROCESSES ON THE COST AND QUALITY OF GEARS PRODUCED WITH AISI 4140 AND 8620 STEELS

    Directory of Open Access Journals (Sweden)

    Claudio José Leitão

    2012-09-01

    Full Text Available This study compares the effects of nitriding and carburizing processes applied to gears subjected to contact stresses below 1300 MPa. The manufacturing cost, as well the depth of hardened layer and the distortion produced by two processes are analyzed. AISI 4140 gears quenched, tempered, liquid and gas nitriding and AISI 8620 gears after liquid carburizing, quenching and tempering are analyzed. The dimensional control of the gears was carried out before and after heat and thermochemical treatments. It is concluded that liquid or gas nitriding processes are about 30% more economical than liquid carburizing an also they reduce the dimensional changes. By the other hand liquid carburizing achieves greater case depth. Liquid nitriding process presents the lowest cost, dimensional changes and case depth.

  3. Resistencia a la abrasión vs. Resistencia al impacto del acero aisi 15b30, templado + revenido

    Directory of Open Access Journals (Sweden)

    HORACIO SIERRA RESTREPO

    2007-01-01

    Full Text Available Debido al bajo carbono de los aceros al boro, algunos fabricantes recomiendan el revenido como tratamiento opcional y otros sugieren que no es necesario. Puesto que los aceros al boro son muy utilizados en aplicaciones agrícolas donde tienen exigencias de desgaste e impacto, (p.ej. discos de arados, es, entonces, conveniente evaluar dichas propiedades del acero AISI 15B30 con temple y temple más revenido a diferentes temperaturas y contrastarlo con características del AISI 1030, obtenidas en condiciones similares. De los resultados obtenidos, se desprende que el revenido a 200ºC después del temple es beneficioso ya que la energía absorbida en el ensayo de impacto es el doble de la obtenida en probetas con solo temple, conservando las propiedades de dureza y resistencia a la abrasión

  4. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  5. Texture analysis of deformation induced martensite in an AISI 301L stainless steel: microtexture and macrotexture aspects

    OpenAIRE

    Hamilton Ferreira Gomes de Abreu; Marcelo José Gomes da Silva; Luís Flávio Gaspar Herculano; Harry Bhadeshia

    2009-01-01

    Experiments have been conducted to study the strain induced transformation from austenite to martensite in a metastable AISI 301LN austenitic stainless steel, deformed by uniaxial tension applied along rolling direction. Samples deformed 10 and 20% have shown the presence of α´ martensite phase. Measured pole figures of martensite phase were compared to calculated ones, assuming no variant selection and selection of variants where interaction between stress and the plate of martensite ad...

  6. Effects of strain-induced martensite and its reversion on the magnetic properties of AISI 201 austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Souza Filho, I.R. [Escola de Engenharia de Lorena, University of Sao Paulo, 12602-810 Lorena (Brazil); Sandim, M.J.R., E-mail: msandim@demar.eel.usp.br [Escola de Engenharia de Lorena, University of Sao Paulo, 12602-810 Lorena (Brazil); Cohen, R.; Nagamine, L.C.C.M. [Instituto de Física, University of Sao Paulo, 05314-970 Sao Paulo (Brazil); Hoffmann, J. [Karlsruher Institut für Technologie, D-72061 Karlsruhe (Germany); Bolmaro, R.E. [Instituto de Física Rosario, CONICET-UNR, 2000 Rosario (Argentina); Sandim, H.R.Z. [Escola de Engenharia de Lorena, University of Sao Paulo, 12602-810 Lorena (Brazil)

    2016-12-01

    Strain-induced martensite (SIM) and its reversion in a cold-rolled AISI 201 austenitic stainless steel was studied by means of magnetic properties, light optical (LOM) and scanning electron (SEM) microscopy, electron backscatter diffraction (EBSD), texture measurements, and Vickers microhardness testing. According to Thermo-calc© predictions, the BCC phase (residual δ-ferrite and SIM) is expected to be stable until 600 °C. The current material was cold rolled up to 60% thickness reduction and submitted to both isothermal and stepwise annealing up to 800 °C. Magnetic measurements were taken during annealing (in situ) of the samples and also for their post mortem conditions. The Curie temperatures (T{sub c}) of residual δ-ferrite and SIM have similar values between 550 and 600 °C. Besides T{sub c}, the focused magnetic parameters were saturation magnetization (M{sub s}), remanent magnetization (M{sub R}), and coercive field (H{sub c}). SIM reversion was found to occur in the range of 600–700 °C in good agreement with Thermo-calc© predictions. The microstructures of the material, annealed at 600 and 700 °C for 1 h, were investigated via EBSD. Microtexture measurements for these samples revealed that the texture components were mainly those found for the 60% cold rolled material. This is an evidence that the SIM reversion occurred by an athermal mechanism. - Highlights: • H{sub c} and M{sub R}/M{sub S} ratio give information about distribution of strain-induced martensite. • According to Thermo-calc©, the BCC phase in AISI 201 steel is stable until 600 °C. • Thermo-calc predictions agrees with magnetic properties of AISI 201 steel. • Possible magnetic anisotropy induced by rolling in AISI 201 steel is investigated.

  7. A Comparative Analysis of Surface Roughness and Material Removal Rate in Milling Operation of AISI 410 Steel And Aluminium 6061

    Directory of Open Access Journals (Sweden)

    Gaurav Kumar,

    2014-06-01

    Full Text Available Surface roughness is an important measure of product quality since it greatly influences the performance of Mechanical parts as well as production cost. Roughness plays an extensive role in demonstrating how the object will interface with the environment. The main purpose of this paper is to analyse the comparative study of Surface Roughness and Material Removal Rate (MRR of Aluminium 6061and AISI 410 Steel. In the present paper three parameters were taken to check whether quality lies within desired tolerance level. Surface roughness and MRR were taken using three different parameters of CNC machining including spindle speed, feed rate and depth of cut. Optimization of surface roughness of aluminium 6061 and AISI 410 Steel were done using Response Surface Methodology. Response Surface Methodology is an adequate channel in which response variable can be optimized by taking several experimental runs. This paper aims to obtain an optimal setting of three milling parameters by using Carbide cutting tool in end milling operation of AISI 410 steel and Aluminium Alloy 6061 taken as specimen.

  8. Plasma nitriding process by direct current glow discharge at low temperature increasing the thermal diffusivity of AISI 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Prandel, L. V.; Somer, A.; Assmann, A.; Camelotti, F.; Costa, G.; Bonardi, C.; Jurelo, A. R.; Rodrigues, J. B.; Cruz, G. K. [Universidade Estadual de Ponta Grossa, Grupo de Espectroscopia Optica e Fotoacustica de Materiais, Departamento de Fisica, Av. Carlos Cavalcanti, 4748, CEP 84030-900, Ponta Grossa, PR (Brazil)

    2013-02-14

    This work reports for the first time on the use of the open photoacoustic cell technique operating at very low frequencies and at room temperature to experimentally determine the thermal diffusivity parameter of commercial AISI304 stainless steel and AISI304 stainless steel nitrided samples. Complementary measurements of X-ray diffraction and scanning electron microscopy were also performed. The results show that in standard AISI 304 stainless steel samples the thermal diffusivity is (4.0 {+-} 0.3) Multiplication-Sign 10{sup -6} m{sup 2}/s. After the nitriding process, the thermal diffusivity increases to the value (7.1 {+-} 0.5) Multiplication-Sign 10{sup -6} m{sup 2}/s. The results are being associated to the diffusion process of nitrogen into the surface of the sample. Carrying out subsequent thermal treatment at 500 Degree-Sign C, the thermal diffusivity increases up to (12.0 {+-} 2) Multiplication-Sign 10{sup -6} m{sup 2}/s. Now the observed growing in the thermal diffusivity must be related to the change in the phases contained in the nitrided layer.

  9. Wear and Adhesive Failure of Al2O3 Powder Coating Sprayed onto AISI H13 Tool Steel Substrate

    Science.gov (United States)

    Amanov, Auezhan; Pyun, Young-Sik

    2016-07-01

    In this study, an alumina (Al2O3) ceramic powder was sprayed onto an AISI H13 hot-work tool steel substrate that was subjected to sanding and ultrasonic nanocrystalline surface modification (UNSM) treatment processes. The significance of the UNSM technique on the adhesive failure of the Al2O3 coating and on the hardness of the substrate was investigated. The adhesive failure of the coating sprayed onto sanded and UNSM-treated substrates was investigated by a micro-scratch tester at an incremental load. It was found, based on the obtained results, that the coating sprayed onto the UNSM-treated substrate exhibited a better resistance to adhesive failure in comparison with that of the coating sprayed onto the sanded substrate. Dry friction and wear property of the coatings sprayed onto the sanded and UNSM-treated substrates were assessed by means of a ball-on-disk tribometer against an AISI 52100 steel ball. It was demonstrated that the UNSM technique controllably improved the adhesive failure of the Al2O3 coating, where the critical load was improved by about 31%. Thus, it is expected that the application of the UNSM technique to an AISI H13 tool steel substrate prior to coating may delay the adhesive failure and improve the sticking between the coating and the substrate thanks to the modified and hardened surface.

  10. A Review of Dental Implant Treatment Planning and Implant Design Based on Bone Density

    Directory of Open Access Journals (Sweden)

    Torkzaban

    2013-06-01

    Full Text Available Context A key determinant for clinical success is the diagnosis of the bone density in a potential implant site. The percentage of bone-implant contact is related to bone density, and the axial stress contours around an implant are affected by the density of bone. Evidence Acquisition A number of reports have emphasized the importance of the quality of bone on the survival of dental implants. The volume and density of the recipient bone have also been shown to be determining criteria to establish proper treatment plans with adequate number of implants and sufficient surface area. Previous clinical reports that did not alter the protocol of treatment related to bone density had variable survival rates. To the contrary, altering the treatment plan to compensate for soft bone types has provided similar survival rates in all bone densities. Results When bone density decreases and bone become softer, the implant surface in contact with the bone decreases, therefore treatment plan should be modified by changing the drilling protocol, using gradual loading and reducing the force on the prosthesis or increasing the loading area with increasing implant number, implant position, implant size, implant design (deeper and more threads with more pitch, squared shape and implant body surface condition. Conclusions Once the prosthetic option, key implant position, and patient force factors have been determined, the bone density in the implant sites should be evaluated to modify the treatment plan. Inappropriate implant number or design in poor quality bone results in higher failure rates. Changing the treatment plan and implant design is suggested, based on bone density to achieve higher survival rates.

  11. Risk factors and periimplantitis in implant therapy. Narrative review

    Directory of Open Access Journals (Sweden)

    Francis Bravo

    2013-12-01

    Full Text Available Diseases involving tissue around the teeth and osseointegrated implants are the result of an interaction between some type of pathological agent (bacterial, viral, etc. and host immune response. These interactions can occur both in the dental tissues as those biomaterials which are introduced to attempt to correct some type of periodontal disease, the implant being a biocompatible substitute of the teeth is not free from this type of interaction often enrolled periodontal and peri-implant pathology. The peri-implantitis is a type of disease that results from this interaction, the risk factors and risk indicators of peri-implantitis are broad and complex. This article summarizes the multiple sources of information in the scientific literature to address in detail the aspects of the main risk factors and the peri-implantitis in the peri implant therapy.

  12. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  13. [Bilateral cochlear implantation].

    Science.gov (United States)

    Kronenberg, Jona; Migirov, Lela; Taitelbaum-Swead, Rikey; Hildesheimer, Minka

    2010-06-01

    Cochlear implant surgery became the standard of care in hearing rehabilitation of patients with severe to profound sensorineural hearing loss. This procedure may alter the lives of children and adults enabling them to integrate with the hearing population. In the past, implantation was performed only in one ear, despite the fact that binaural hearing is superior to unilateral, especially in noisy conditions. Cochlear implantation may be performed sequentially or simultaneously. The "sensitive period" of time between hearing loss and implantation and between the two implantations, when performed sequentially, significantly influences the results. Shorter time spans between implantations improve the hearing results after implantation. Hearing success after implantation is highly dependent on the rehabilitation process which includes mapping, implant adjustments and hearing training. Bilateral cochlear implantation in children is recommended as the proposed procedure in spite of the additional financial burden.

  14. Microestrutura de uma Solda Dissimilar entre o Aço Inoxidável Ferrítico AISI 410S e o Aço Inoxidável Austenítico AISI 304L Soldado pelo Processo FSW

    OpenAIRE

    Tathiane Caminha Andrade; Cleiton Carvalho Silva; Hélio Cordeiro de Miranda; Marcelo Ferreira Motta; Jesualdo Pereira Farias; Luciano Andrei Bergman; Jorge Fernandes dos Santos

    2015-01-01

    Resumo O presente trabalho visa investigar a microestrutura formada na soldagem dissimilar entre chapas de aços inoxidáveis ferríticos AISI 410S e aços inoxidáveis austeníticos AISI 304L pelo processo friction stir welding. A soldagem foi realizada com o ajuste dos seguintes parâmetros: rotação 450 rpm; velocidade de soldagem de 1,0 mm/s; e força axial 40 kN. O aço AISI 410S foi posicionado no lado de avanço enquanto que o aço AISI 304L foi posicionado no lado de retrocesso. A análise consist...

  15. Evaluación del coeficiente de endurecimiento del acero AISI 1045 deformado por rodillo

    Directory of Open Access Journals (Sweden)

    D. Alcántara

    2011-12-01

    Full Text Available El objetivo del trabajo es determinar el comportamiento del coeficiente de endurecimiento n por la ecuación de Hollomon en muestras cilíndricas de acero AISI 1045, las cuales, después de ser deformadas, se sometieron a ensayos de tracción. Se utiliza un diseño de experimento donde se tienen en cuenta las variables número de revolución (n con 27, 54 y 110 rev/min, fuerza de compresión (P de 500, 1 500 y   2 500 N y avance (S de 0,075; 0,125 y 0,25 mm/rev. Finalmente, aplicando el método de regresión se obtuvo un coeficiente de endurecimiento, el cual se aproxima a la linealidad cuando restringimos el cálculo a rangos de deformación elevados. Este coeficiente de endurecimiento se aplica en la ecuación de Hollomon para determinar el nuevo valor de tensión de fluencia y aplicarlo para el cálculo del trabajo mínimo a realizar en un proceso de deformación en frío empleando rodillo simple.   Palabras clave: Deformación Plástica; tensión; deformación; endurecimiento.The objective of the work is to determine the behavior of the hardening coefficient n by the equation of Hollomon, in cylindrical samples of steel AISI 1045, those which, after the deformed, were subjected to traction rehearsals. He used an experiment design where are kept in mind the revolution number (n with 27, 54 and 110 rev/min, it compression forces (P of 500, 1 500 and 2 500 N and feed (S of 0.075; 0.125 and 0.25 mm/rev. Finally, applying the regression method a hardening coefficient was obtained, which approaches to the linearity when restrict the calculation to high ranges of deformation. This hardening coefficient is applied in the equation of Hollomon for determine the new value of flow tension and to apply in the calculation of the minimum work to carry out in a cold process of deformation using simple roller.   Keywords: Plastic deformation; stress; deformation; hardening.

  16. Port type is a possible risk factor for implantable venous access port-related bloodstream infections and no sign of local infection predicts the growth of gram-negative bacilli.

    Science.gov (United States)

    Hsu, Jui-Feng; Chang, Hsu-Liang; Tsai, Ming-Ju; Tsai, Ying-Ming; Lee, Yen-Lung; Chen, Pei-Huan; Fan, Wen-Chieh; Su, Yu-Chung; Yang, Chih-Jen

    2015-09-30

    Implantable venous access port (IVAP)-related blood stream infections (BSIs) are one of the most common complications of implantable venous ports. The risk factors and pathogens for IVAP-related BSIs are still controversial. We retrospectively reviewed all patients who received IVAPs at a Hospital in Taiwan from January 1, 2011 to June 31, 2014. Two types of venous port, BardPort® 6.6 fr (Bard port) and Autosuture Chemosite® 7.5 fr (TYCO port) were used. All patients with clinically proven venous port-related BSIs were enrolled. A total of 552 patients were enrolled. There were 34 episodes of IVAP-related BSIs during the study period for a total incidence of 0.177 events/1000 catheter days. Port type (TYCO vs. Bard, HR = 7.105 (95% confidence interval (CI), 1.688-29.904), p = 0.0075), age > 65 years (HR = 2.320 (95 % CI, 1.179-4.564), p = 0.0148), and lung cancer (HR = 5.807 (95% CI, 2.946-11.447), p gram-negative bacilli (p = 0.031). TYCO venous ports, age > 65 years, and lung cancer were all significant risk factors for IVAP-related BSIs, and no sign of infection was significantly associated with the growth of gram-negative bacilli.

  17. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants.

    Science.gov (United States)

    Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I

    2017-03-10

    The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.

  18. Effects of Jet Pressure on the Ground Surface Quality and CBN Wheel Wear in Grinding AISI 690 Nickel-Based Superalloy

    Science.gov (United States)

    Guitouni, Ahmed; Chaieb, Iheb; Rhouma, Amir Ben; Fredj, Nabil Ben

    2016-09-01

    Fluid application in grinding is getting attention as higher stock removal rates, higher surface integrity and longer wheel life are required. It is necessary to define proper conditions of application for meeting high productivity goals by lowering the specific grinding energy and reducing the temperature of the contact zone. The present study investigated the capacity of the jet pressure of a spot nozzle to improve the wear of a CBN wheel when grinding the AISI 690 superalloy. Grinding experiments were conducted with an emulsion-type cooling fluid delivered at pressure ranging from 0.1 to 4 MPa. Results show that the maximum stock removal, reached at 4 MPa, is 5 times the stock removal obtained at 0.1 MPa, while the grinding ratio at 4 MPa is 8 times that at 0.1 MPa, and there is a critical pressure (P c) around 1.5 MPa corresponding to the minimum specific grinding energy. Scanning electron microscopy of the grain tips showed that the wear mechanism shifts from breaking and dislodgment at low jet pressure to micro-fracture resulting in continuous self-sharpening of the abrasive grains. By lubricating at jet pressure close to P c, there is less thermal damage due to plowing and sliding and the resulting lower loading of the abrasive grains favors the micro-fracture of grains and thus a longer wheel life.

  19. Effect of Welding Current and Time on the Microstructure, Mechanical Characterizations, and Fracture Studies of Resistance Spot Welding Joints of AISI 316L Austenitic Stainless Steel

    Science.gov (United States)

    Kianersi, Danial; Mostafaei, Amir; Mohammadi, Javad

    2014-09-01

    This article aims at investigating the effect of welding parameters, namely, welding current and welding time, on resistance spot welding (RSW) of the AISI 316L austenitic stainless steel sheets. The influence of welding current and welding time on the weld properties including the weld nugget diameter or fusion zone, tensile-shear load-bearing capacity of welded materials, failure modes, energy absorption, and microstructure of welded nuggets was precisely considered. Microstructural studies and mechanical properties showed that the region between interfacial to pullout mode transition and expulsion limit is defined as the optimum welding condition. Electron microscopic studies indicated different types of delta ferrite in welded nuggets including skeletal, acicular, and lathy delta ferrite morphologies as a result of nonequilibrium phases, which can be attributed to a fast cooling rate in the RSW process. These morphologies were explained based on Shaeffler, WRC-1992, and pseudo-binary phase diagrams. The optimum microstructure and mechanical properties were achieved with 8-kA welding current and 4-cycle welding time in which maximum tensile-shear load-bearing capacity or peak load of the welded materials was obtained at 8070 N, and the failure mode took place as button pullout with tearing from the base metal. Finally, fracture surface studies indicated that elongated dimples appeared on the surface as a result of ductile fracture in the sample welded in the optimum welding condition.

  20. Effects of Jet Pressure on the Ground Surface Quality and CBN Wheel Wear in Grinding AISI 690 Nickel-Based Superalloy

    Science.gov (United States)

    Guitouni, Ahmed; Chaieb, Iheb; Rhouma, Amir Ben; Fredj, Nabil Ben

    2016-11-01

    Fluid application in grinding is getting attention as higher stock removal rates, higher surface integrity and longer wheel life are required. It is necessary to define proper conditions of application for meeting high productivity goals by lowering the specific grinding energy and reducing the temperature of the contact zone. The present study investigated the capacity of the jet pressure of a spot nozzle to improve the wear of a CBN wheel when grinding the AISI 690 superalloy. Grinding experiments were conducted with an emulsion-type cooling fluid delivered at pressure ranging from 0.1 to 4 MPa. Results show that the maximum stock removal, reached at 4 MPa, is 5 times the stock removal obtained at 0.1 MPa, while the grinding ratio at 4 MPa is 8 times that at 0.1 MPa, and there is a critical pressure ( P c) around 1.5 MPa corresponding to the minimum specific grinding energy. Scanning electron microscopy of the grain tips showed that the wear mechanism shifts from breaking and dislodgment at low jet pressure to micro-fracture resulting in continuous self-sharpening of the abrasive grains. By lubricating at jet pressure close to P c, there is less thermal damage due to plowing and sliding and the resulting lower loading of the abrasive grains favors the micro-fracture of grains and thus a longer wheel life.

  1. Estimation of Fatigue Life of Laser Welded AISI304 Stainless Steel T-Joint Based on Experiments and Recommendations in Design Codes

    DEFF Research Database (Denmark)

    Lambertsen, Søren Heide; Damkilde, Lars; Kristensen, Anders Schmidt;

    2013-01-01

    In this paper the fatigue behavior of laser welded T-joints of stainless steel AISI304 is investigated experimentally. In the fatigue experiments 36 specimens with a sheet thickness of 1 mm are exposed to one-dimensional cyclic loading. Three different types of specimens are adopted. Three groups....... The non-welded specimens are used to study the influence of heat and surface effects on the fatigue life. The fatigue life from the experiments is compared to fatigue life calculated from the guidelines in the standards DNV-RP-C203 and EUROCODE 3 EN-1993-1-9. Insignificant differences in fatigue life...... of the welded and non-welded specimens are observed in the experiments and the largest difference is found in the High Cycle Fatigue (HCF) area. The specimens show a lower fatigue life compared to DNV-RP-C203 and EUROCODE 3 EN-1993-1-9 when the spe-cimens are exposed to less than 4.0 1E06 cycles. Therefore, we...

  2. Clinical and esthetic outcomes of implants placed in postextraction sites.

    Science.gov (United States)

    Chen, Stephen T; Buser, Daniel

    2009-01-01

    The aim of this review was to evaluate the clinical outcomes for the different time points of implant placement following tooth extraction. A PubMed search and a hand search of selected journals were performed to identify clinical studies published in English that reported on outcomes of implants in postextraction sites. Only studies that included 10 or more patients were accepted. For implant success/survival outcomes, only studies with a mean follow-up period of at least 12 months from the time of implant placement were included. The following outcomes were identified: (1) change in peri-implant defect dimension, (2) implant survival and success, and (3) esthetic outcomes. Of 1,107 abstracts and 170 full-text articles considered, 91 studies met the inclusion criteria for this review. Bone augmentation procedures are effective in promoting bone fill and defect resolution at implants in postextraction sites, and are more successful with immediate (type 1) and early placement (type 2 and type 3) than with late placement (type 4). The majority of studies reported survival rates of over 95%. Similar survival rates were observed for immediate (type 1) and early (type 2) placement. Recession of the facial mucosal margin is common with immediate (type 1) placement. Risk indicators included a thin tissue biotype, a facial malposition of the implant, and a thin or damaged facial bone wall. Early implant placement (type 2 and type 3) is associated with a lower frequency of mucosal recession compared to immediate placement (type 1).

  3. Hall effect studies of donors and acceptors in different types of bulk ZnO modified by annealing and hydrogen implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kassier, G.H.; Hayes, M.; Auret, F.D.; Diale, M. [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Svensson, B.G. [Department of Physics, Centre for Material Science and Nanotechnology, University of Oslo, P.O. Box 1048 Blindern, 0316 Oslo (Norway)

    2008-07-01

    Samples of as-manufactured and annealed zinc oxide (ZnO) grown by melt-growth, seeded chemical vapour transport (SCVT) growth and hydrogen-implanted hydrothermal ZnO were investigated via the temperature dependent Hall technique. The conduction in the melt-grown sample appeared to be dominated by two donors with activation energies of about 70 meV and 44 meV, the former disappearing with annealing above 550 C. Only one dominant donor of about 80 meV was found in the SCVT-grown sample and it showed little change with annealing. Surface conduction effects were observed only in the SCVT-grown sample. Hydrogen-implanted hydrothermal ZnO layers were found to have only one dominant donor with activation energy of about 45 meV that was stable up to annealing temperatures of about 300 C. The acceptor concentration was found to increase considerably with annealing above 300 C. We attempt to interpret these results by considering theoretical predictions for the various native and extrinsic defects expected to occur in our samples. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Investigations on Surface Milling of Hardened AISI 4140 Steel with Pulse Jet MQL Applicator

    Science.gov (United States)

    Bashir, Mahmood Al; Mia, Mozammel; Dhar, Nikhil Ranjan

    2016-06-01

    In this article, an experimental investigation was performed in milling hardened AISI 4140 steel of hardness 40 HRC. The machining was performed in both dry and minimal quantity lubricant (MQL) conditions, as part of neat machining, to make a strong comparison of the undertaken machining environments. The MQL was impinged int the form of pulse jet, by using the specially developed pulse-jet-attachment, to ensure that the cutting fluid can be applied in different timed pulses and quantities at critical zones. The tool wear, cutting force and surface roughness were taken as the quality responses while cutting speed, table feed rate and flow rate of the pulse were considered as influential factors. The depth of cut was kept constant at 1.50 mm because of its less significant effects and the straight oil was adopted as cutting fluid in pulse-jet-MQL. The effects of different factors, on the quality responses, are analyzed using ANOVA. It is observed that MQL applicator system exhibits overall better performance when compared to dry milling by reducing surface roughness, cutting force and prolonging tool life but a flow rate of 150 ml/h has tremendous effects on the responses. This investigation and afterward results are expected to aid the industrial practitioner and researcher to adopt the pulse-MQL in high speed milling to prolong tool life, reduce tool wear, diminish cutting force generation and promote better surface finish.

  5. Investigation on Friction and Wear of Cold Rolled High Strength Steel against an AISI52100 Counterpart

    Directory of Open Access Journals (Sweden)

    Jiwon Hur

    2017-03-01

    Full Text Available This article investigates the friction and wear of cold rolled high strength steel at various displacement amplitudes. Reciprocal sliding tests are carried out using a ball-on-flat testing apparatus. The tangential force occurring at the contact surface between a high strength steel specimen and an AISI52100 ball is measured during the tests. After each test, the worn surface profile on the steel specimen is determined. Experimental results show that the ratio of the maximum tangential to the normal force remains at 0.7 after an initial rapid increase, and the ratio does not greatly change according to the imposed displacement amplitudes (in the range of 0.05 mm and 0.3 mm. The wear volume loss on the steel specimen increases according to the number of cycles. It is determined that the wear rate of the specimen changes with respect to the imposed displacement amplitude. That is, the wear rate rapidly increases within the displacement amplitude range of 0.05 mm to 0.09 mm, while the wear rate gradually increases when the displacement amplitude is greater than 0.2 mm. The obtained results provide the friction and wear behaviors of cold rolled high strength steel in fretting and reciprocal sliding regimes.

  6. Corrosion of aluminium, stainless steels and AISI 680 nickel alloy in nitrogen-based fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kap, I.; Starostin, M.; Shter, G.E.; Grader, G.S. [Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa (Israel)

    2012-07-15

    Nitrogen-based compounds can potentially be used as alternative non-carbon or low-carbon fuels. Nevertheless, the corrosion of construction materials at high temperatures and pressures in the presence of such fuel has not been reported yet. This work is focused on the corrosion of AISI Al 6061, 1005 carbon steel (CS), 304, 316L, 310 austenitic stainless steels (SS) and 680 nickel alloy in highly concentrated water solution of ammonium nitrate and urea (ANU). The corrosion at 50 C and ambient pressure and at 350 C and 20 bar was investigated to simulate storage and working conditions. Sodium chloride was added to the fuel (0-5 wt%) to simulate industrial fertilizers and accelerated corrosion environment. Heavy corrosion of CS was observed in ANU solution at 50 C, while Al 6061, 304 and 316L SS showed high resistance both to uniform and pitting corrosion in ANU containing 1% of sodium chloride. Addition of 5% sodium chloride caused pitting of Al 6061 but had no influence on the corrosion of SS. Tests in ANU at 350 C and 20 bar showed pitting on SS 304 and 316L and 680 nickel alloy. The highest corrosion resistance was found for SS 310 due to formation of stable oxide film on its surface. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Investigation of the influential parameters of machining of AISI 304 stainless steel

    Indian Academy of Sciences (India)

    R A Mahdavinejad; S Saeedy

    2011-12-01

    Austenitic stainless steels are hard materials to machine, due to their high strength, high ductility and low thermal conductivity. The last characteristic results in heat concentration at the tool cutting edge. This paper aims to optimize turning parameters of AISI 304 stainless steel. Turning tests have been performed in three different feed rates (0.2, 0.3, 0.4 mm/rev) at the cutting speeds of 100, 125, 150, 175 and 200 m/min with and without cutting fluid. A design of experiments (DOE) and an analysis of variance (ANOVA) have been made to determine the effects of each parameter on the tool wear and the surface roughness. It is being inferred that cutting speed has the main influence on the flank wear and as it increases to 175 m/min, the flank wear decreases. The feed rate has the most important influence on the surface roughness and as it decreases, the surface roughness also decreases. Also, the application of cutting fluid results in longer tool life and better surface finish.

  8. Z phase stability in AISI 316LN + Nb austenitic steels during creep at 650 C

    Energy Technology Data Exchange (ETDEWEB)

    Vodarek, Vlastimil [Technical Univ. Ostrava (Czech Republic)

    2010-07-01

    The creep resistance of austenitic CrNi(Mo) steels strongly depends on microstructural stability during creep exposure. Nitrogen additions to CrNi(Mo) austenitic steels can significantly improve the creep strength. One of the most successful methods of improving the long-term creep resistance of austenitic steels is based on increasing the extent of precipitation strengthening during creep exposure. The role of precipitates in the achievements of good creep properties has been extensively studied for a long time. Although many minor phases are now well documented there are still contractions and missing thermodynamic data about some minor phases. This contribution deals with results of microstructural studies on the minor phase evolution in wrought AISI 316LN niobium stabilised steels during long-term creep exposure at 650 C. Microstructural investigations were carried out on specimens taken from both heads and gauge lengths of ruptured test-pieces by means of optical metallography, transmission and scanning electron microscopy. The attention has been paid to evaluation of thermodynamic and dimensional stability of Z phase and other nitrogen bearing minor phases. Only two nitrogen-bearing minor phases formed in the casts investigated: Z phase and M{sub 6}X. The dimensional stability of Z phase particles was very high. (orig.)

  9. Metallurgical response of an AISI 4140 steel to different plasma nitriding gas mixtures

    Directory of Open Access Journals (Sweden)

    Adão Felipe Oliveira Skonieski

    2013-01-01

    Full Text Available Plasma nitriding is a surface modification process that uses glow discharge to diffuse nitrogen atoms into the metallic matrix of different materials. Among the many possible parameters of the process, the gas mixture composition plays an important role, as it impacts directly the formed layer's microstructure. In this work an AISI 4140 steel was plasma nitrided under five different gas compositions. The plasma nitriding samples were characterized using optical and scanning electron microscopy, microhardness test, X-ray diffraction and GDOES. The results showed that there are significant microstructural and morphological differences on the formed layers depending on the quantity of nitrogen and methane added to the plasma nitriding atmosphere. Thicknesses of 10, 5 and 2.5 µm were obtained when the nitrogen content of the gas mixtures were varied. The possibility to obtain a compound layer formed mainly by γ'-Fe4N nitrides was also shown. For all studied plasma nitriding conditions, the presence of a compound layer was recognized as being the responsible to hinder the decarburization on the steel surface. The highest value of surface hardness - 1277HV - were measured in the sample which were nitrided with 3vol.% of CH4.

  10. Effect of Beam Oscillation on Microstructure and Mechanical Properties of AISI 316L Electron Beam Welds

    Science.gov (United States)

    Kar, Jyotirmaya; Roy, Sanat Kumar; Roy, Gour Gopal

    2017-02-01

    The properties of electron beam-welded AISI 316L stainless steel butt joints prepared with and without beam oscillation were evaluated by microstructural analysis, mechanical testing like microhardness measurements, tensile tests at room and elevated temperature 973 K (700 °C), three-point bend, and Charpy impact tests. All joints, irrespective of being prepared with or without beam oscillation, were found to be defect free. Welds produced by beam oscillation exhibited narrower fusion zone (FZ) with lathy ferrite morphology, while the weld without beam oscillation was characterized by wider FZ and skeletal ferrite morphology. During tensile tests at room and elevated temperature 973 K (700 °C), all samples fractured in the base metal (BM) and showed almost the same tensile properties as that of the BM. However, the notch tensile tests at room temperature demonstrated higher strength for joints prepared with the oscillating beam. Besides, face and root bend tests, as well as Charpy impact tests, showed higher bending strength and notch toughness, respectively, for joints prepared with beam oscillation.

  11. Welding of AA1050 aluminum with AISI 304 stainless steel by rotary friction welding process

    Directory of Open Access Journals (Sweden)

    Chen Ying An

    2010-09-01

    Full Text Available The purpose of this work was to assess the development of solid state joints of dissimilar material AA1050 aluminum and AISI 304 stainless steel, which can be used in pipes of tanks of liquid propellants and other components of the Satellite Launch Vehicle. The joints were obtained by rotary friction welding process (RFW, which combines the heat generated from friction between two surfaces and plastic deformation. Tests were conducted with different welding process parameters. The results were analyzed by means of tensile tests, Vickers microhardness, metallographic tests and SEM-EDX. The strength of the joints varied with increasing friction time and the use of different pressure values. Joints were obtained with superior mechanical properties of the AA1050 aluminum, with fracture occurring in the aluminum away from the bonding interface. The analysis by EDX at the interface of the junction showed that interdiffusion occurs between the main chemical components of the materials involved. The RFW proves to be a great method for obtaining joints between dissimilar materials, which is not possible by fusion welding processes.

  12. Nano- and Macro-wear of Bio-carbo-nitrided AISI 8620 Steel Surfaces

    Science.gov (United States)

    Arthur, Emmanuel Kwesi; Ampaw, Edward; Zebaze Kana, M. G.; Adetunji, A. R.; Olusunle, S. O. O.; Adewoye, O. O.; Soboyejo, W. O.

    2015-12-01

    This paper presents the results of an experimental study of nano- and macro-scale wear in a carbo-nitrided AISI 8620 steel. Carbo-nitriding is carried out using a novel method that involves the use of dried, cyanide-containing cassava leaves, as sources of carbon and nitrogen. These are used in a pack cementation that is used to diffuse carbon and nitrogen into case layers at intermediate temperatures [673.15 K, 723.15 K, 773.15 K, and 823.15 K (400 °C, 450 °C, 500 °C, and 550 °C)]. Nano- and macro-scale wear properties are studied in the case-hardened surfaces, using a combination of nano-scratch and pin-on-disk experiments. The measured wear volumes (at both nano- and macro-length scales) are shown to increase with decreasing pack cyaniding temperature. The nano- and macro-wear resistances are also shown to be enhanced by the in situ diffusion of carbon and nitrogen from cyanide-containing bio-processed waste. The underlying wear mechanisms are also elucidated via atomic force microscopy and scanning electron microscopy observations of the wear tracks. The implications of the results are discussed for the design of hardened carbo-nitrided steel surfaces with improved wear resistance.

  13. Effect of Beam Oscillation on Microstructure and Mechanical Properties of AISI 316L Electron Beam Welds

    Science.gov (United States)

    Kar, Jyotirmaya; Roy, Sanat Kumar; Roy, Gour Gopal

    2017-04-01

    The properties of electron beam-welded AISI 316L stainless steel butt joints prepared with and without beam oscillation were evaluated by microstructural analysis, mechanical testing like microhardness measurements, tensile tests at room and elevated temperature 973 K (700 °C), three-point bend, and Charpy impact tests. All joints, irrespective of being prepared with or without beam oscillation, were found to be defect free. Welds produced by beam oscillation exhibited narrower fusion zone (FZ) with lathy ferrite morphology, while the weld without beam oscillation was characterized by wider FZ and skeletal ferrite morphology. During tensile tests at room and elevated temperature 973 K (700 °C), all samples fractured in the base metal (BM) and showed almost the same tensile properties as that of the BM. However, the notch tensile tests at room temperature demonstrated higher strength for joints prepared with the oscillating beam. Besides, face and root bend tests, as well as Charpy impact tests, showed higher bending strength and notch toughness, respectively, for joints prepared with beam oscillation.

  14. Surface Nanostructure Formations in an AISI 316L Stainless Steel Induced by Pulsed Electron Beam Treatment

    Directory of Open Access Journals (Sweden)

    Yang Cai

    2015-01-01

    Full Text Available High current pulsed electron beam (HCPEB is an efficient technique for surface modifications of metallic materials. In the present work, the formations of surface nanostructures in an AISI 316L stainless steel induced by direct HCPEB treatment and HCPEB alloying have been investigated. After HCPEB Ti alloying, the sample surface contained a mixture of the ferrite and austenite phases with an average grain size of about 90 nm, because the addition of Ti favors the formation of ferrite. In contrast, electron backscattered diffraction (EBSD analyses revealed no structural refinement on the direct HCPEB treated sample. However, transmission electron microscope (TEM observations showed that fine cells having an average size of 150 nm without misorientations, as well as nanosized carbide particles, were formed in the surface layer after the direct HCPEB treatment. The formation of nanostructures in the 316L stainless steel is therefore attributed to the rapid solidification and the generation of different phases other than the steel substrate in the melted layer.

  15. Parametric optimization during machining of AISI 304 Austenitic Stainless Steel using CVD coated DURATOMIC cutting insert

    Directory of Open Access Journals (Sweden)

    M. Kaladhar

    2012-08-01

    Full Text Available In this work, Taguchi method is applied to determine the optimum process parameters for turning of AISI 304 austenitic stainless steel on CNC lathe. A Chemical vapour deposition (CVD coated cemented carbide cutting insert is used which is produced by DuratomicTM technology of 0.4 and 0.8 mm nose radii. The tests are conducted at four levels of Cutting speed, feed and depth of cut. The influence of these parameters are investigated on the surface roughness and material removal rate (MRR. The Analysis Of Variance (ANOVA is also used to analyze the influence of cutting parameters during machining. The results revealed that cutting speed significantly (46.05% affected the machined surface roughness values followed by nose radius (23.7%. The influence of the depth of cut (61.31% in affecting material removal rate (MRR is significantly large. The cutting speed (20.40% is the next significant factor. Optimal range and optimal level of parameters are also predicted for responses.

  16. Influence of cyclic temperature changes on the microstructure of AISI 4140 after laser surface hardening

    Energy Technology Data Exchange (ETDEWEB)

    Miokovic, T. [Institute of Materials Science and Engineering I, University of Karlsruhe, 76131 Karlsruhe (Germany); Schulze, V. [Institute of Materials Science and Engineering I, University of Karlsruhe, 76131 Karlsruhe (Germany)]. E-mail: volker.schulze@mach.uni-karlsruhe.de; Voehringer, O. [Institute of Materials Science and Engineering I, University of Karlsruhe, 76131 Karlsruhe (Germany); Loehe, D. [Institute of Materials Science and Engineering I, University of Karlsruhe, 76131 Karlsruhe (Germany)

    2007-01-15

    In recent years laser surface hardening using pulsed laser sources has become an increasingly established technology in engineering industry and has opened up wider possibilities for the application of selective surface hardening. However, the choice of the process parameters is generally based on experience rather than on their empirical influence on the resulting microstructure, and for hardening processes with cyclic temperature changes, almost no correlations between process parameters and hardening results are known. Therefore, some problems regarding the choice of the process parameters and their influence on the resulting microstructure still remain. In particular, there is a lack of data concerning the effect of cyclic temperature changes on hardening. To facilitate process optimization, this paper deals with a detailed characterization of the microstructures created in quenched and tempered AISI 4140 (German grade 42CrMo4) steel following a temperature-dependent laser surface hardening treatment. The structure properties were obtained from microhardness measurements, scanning electron microscopy investigations and X-ray diffraction analysis of retained austenite.

  17. Kinetics of niobium carbide coating produced on AISI 1040 steel by thermo-reactive deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ugur

    2004-07-15

    There are a lot of technologically interesting characteristics of niobium carbide coating deposited by pack method which is the production of hard, wear-resistant, oxidation and corrosion resistant coating layer on the steel substrates. In the present study, the growth kinetics of niobium carbide layer deposited by thermo-reactive diffusion techniques in a solid medium on steel samples was reported. Niobium carbide coating treatment was performed on AISI 1040 steels in the powder mixture consisting of ferro-niobium, ammonium chloride and alumina at 1073, 1173 and 1273 K for 1-4 h. The presence of NbC and Nb{sub 2}C phases formed on the surface of the steel substrates was confirmed by optical microscopy, scanning electron microscopy (SEM) and X-ray diffraction analyses. Niobium carbide layer thickness ranges from 3.42{+-}0.52 to 11.78{+-}2.29 {mu}m depending upon the treatment time and temperature. Layer growth kinetics was analyzed by measuring the depth of niobium carbide layer as a function of time and temperature. The kinetics of niobium carbide coating by pack method shows a parabolic relationship between carbide layer thickness and treatment time, and the activation energy for the process is estimated to be 91.257 kJ mol{sup -1}. Moreover, an attempt was made to investigate the possibility of predicting the contour diagram of niobium carbide layer variation and to establish some empirical relationships between process parameters and niobium carbide layer thickness.

  18. Multi-response optimization of Micro-EDM process parameters on AISI304 steel using TOPSIS

    Energy Technology Data Exchange (ETDEWEB)

    Manivannan, R.; Kumar, M. Pradeep [CEG, Anna University, Chennai (India)

    2016-01-15

    The Technique for order preference by similarity to ideal solution (TOPSIS) method of optimization is used to analyze the process parameters of the micro-Electrical discharge machining (micro-EDM) of an AISI 304 steel with multi-performance characteristics. The Taguchi method of experimental design L27 is performed to obtain the optimal parameters for inputs, including feed rate, current, pulse on time, and gap voltage. Several output responses, such as the material removal rate, electrode wear rate, overcut, taper angle, and circularity at entry and exit points, are analyzed for the optimal conditions. Among all the investigated parameters, feed rate exerts a greater influence on the hole quality. ANOVA is employed to identify the contribution of each experiment. The optimal level of parameter setting is maintained at a feed rate of 4 μm/s, a current of 10 A, a pulse on time of 10 μs, and a gap voltage of 10 V. Scanning electron microscope analysis is conducted to examine the hole quality. The experimental results indicate that the optimal level of the process parameter setting over the overall performance of the micro-EDM is improved through TOPSIS.

  19. Microstructure analysis of AISI 304 stainless steel produced by twin-roll thin strip casting process

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The microstructure of AISI 304 austenite stainless steel fabricated by the thin strip casting process were investigated using optical microscope, scanning electron microscope (SEM), transmission electron microscope (TEM), and X-ray diffraction (XRD).The microstructures of the casting strips show a duplex structure consisting of delta ferrite and austenite. The volume fraction of the delta ferrite is about 9.74vol% at the center and 6.77vol% at the surface of the casting thin strip, in vermicular and band shapes. On account of rapid cooling and solidification in the continuous casting process, many kinds of inclusions and precipitates have been found. Most of the inclusions and precipitates are spherical complex compounds consisting of oxides, such as, SiO2, MnO, Al2O3,Cr2O3,and FeO or their multiplicity oxides of MnO·Al2O3,2FeO·SiO2, and 2MnO·SiO2. Many defects including dislocations and stacking faults have also formed during the rapid cooling and solidification process, which is helpful to improve the mechanical properties of the casting strips.

  20. Z phase stability in AISI 316LN + Nb austenitic steels during creep at 650 C

    Energy Technology Data Exchange (ETDEWEB)

    Vodarek, Vlastimil [Technical Univ. Ostrava (Czech Republic)

    2010-07-01

    The creep resistance of austenitic CrNi(Mo) steels strongly depends on microstructural stability during creep exposure. Nitrogen additions to CrNi(Mo) austenitic steels can significantly improve the creep strength. One of the most successful methods of improving the long-term creep resistance of austenitic steels is based on increasing the extent of precipitation strengthening during creep exposure. The role of precipitates in the achievements of good creep properties has been extensively studied for a long time. Although many minor phases are now well documented there are still contractions and missing thermodynamic data about some minor phases. This contribution deals with results of microstructural studies on the minor phase evolution in wrought AISI 316LN niobium stabilised steels during long-term creep exposure at 650 C. Microstructural investigations were carried out on specimens taken from both heads and gauge lengths of ruptured test-pieces by means of optical metallography, transmission and scanning electron microscopy. The attention has been paid to evaluation of thermodynamic and dimensional stability of Z phase and other nitrogen bearing minor phases. Only two nitrogen-bearing minor phases formed in the casts investigated: Z phase and M{sub 6}X. The dimensional stability of Z phase particles was very high. (orig.)

  1. Effect of laser shock peening on bending fatigue performance of AISI 9310 steel spur gear

    Science.gov (United States)

    Peng, Chong; Xiao, Yuzhe; Wang, Yanzhong; Guo, Wei

    2017-09-01

    The effect of laser shock peening (LSP) on bending fatigue performance of AISI 9310 steel spur gear has been investigated in this study. To help to explain bending fatigue test results, residual stress distribution induced by LSP is studied by means of finite element modelling, results of which are verified by X-ray diffraction analysis. It is found that a compressive layer of desirable depth can be induced on the gear root fillet after LSP, and both magnitude and depth of compressive stress increase with laser energy. The bending fatigue test is conducted using the single-tooth bending method to compare fatigue performance of laser peened teeth and non-peened teeth, which is followed by relevant statistical analysis. S-N curves acquired from the fatigue test reveal that bending fatigue lives of gear teeth has been significantly improved after LSP in comparison with those non-peened teeth, and the bending fatigue limit is enhanced correspondingly. It is noticeable that higher laser energy does not necessarily lead to much better fatigue performance of test gears.

  2. Effects of cold working on the pitting corrosion behavior s of AISI 304 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kee Min; Kim, Jong Soo; Kim, Young Jun; Kwon, Houk Sang [KAIST, Daejon (Korea, Republic of)

    2015-12-15

    These microstructural changes by cold working can lead improvement of mechanical properties, however from a corrosion resistant point of view, the effects of cold working on the corrosion resistance of stainless steel have been argued. Several studies has been focused on the influence of cold working on the localized corrosion resistance of stainless steels. However, the opinions about the role of cold working on the localized corrosion resistance are highly in consistence. Some studies report that the pitting potential of austenitic stainless steels decreased with cold working level, on the other hands, other studies claimed that the pitting resistance was increased by cold working. Therefore it is necessary to verify how cold working affects pitting corrosion behavior of austenitic stainless steels. In the present work, the influence of cold working on the localized corrosion of AISI 304stainless steel in the neutral chloride solution was studied based on point defect model (PDM). The fraction of deformation-induced martensite was linearly increased with cold rolling level. Through cold rolling, the pitting potential was decreased, the metastable pitting event density was significantly increased and the repassivation potential was decreased. The overall localized corrosion resistance was decreased with cold working, however cold working level increased from 30 % to 50 %, localized corrosion resistance was recovered. The accumulated cation vacancy generates a void at metal/film interface, therefore film breakdown accelerates for cold worked alloys.

  3. Computational Modeling of Microstructural-Evolution in AISI 1005 Steel During Gas Metal Arc Butt Welding

    Science.gov (United States)

    Grujicic, M.; Ramaswami, S.; Snipes, J. S.; Yavari, R.; Arakere, A.; Yen, C.-F.; Cheeseman, B. A.

    2013-05-01

    A fully coupled (two-way), transient, thermal-mechanical finite-element procedure is developed to model conventional gas metal arc welding (GMAW) butt-joining process. Two-way thermal-mechanical coupling is achieved by making the mechanical material model of the workpiece and the weld temperature-dependent and by allowing the potential work of plastic deformation resulting from large thermal gradients to be dissipated in the form of heat. To account for the heat losses from the weld into the surroundings, heat transfer effects associated with natural convection and radiation to the environment and thermal-heat conduction to the adjacent workpiece material are considered. The procedure is next combined with the basic physical-metallurgy concepts and principles and applied to a prototypical (plain) low-carbon steel (AISI 1005) to predict the distribution of various crystalline phases within the as-welded material microstructure in different fusion zone and heat-affected zone locations, under given GMAW-process parameters. The results obtained are compared with available open-literature experimental data to provide validation/verification for the proposed GMAW modeling effort.

  4. Thermodynamic modeling and kinetics simulation of precipitate phases in AISI 316 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Y., E-mail: yangying@ornl.gov [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Busby, J.T. [Fusion and Materials for Nuclear Systems Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2014-05-01

    This work aims at utilizing modern computational microstructural modeling tools to accelerate the understanding of phase stability in austenitic steels under extended thermal aging. Using the CALPHAD approach, a thermodynamic database OCTANT (ORNL Computational Thermodynamics for Applied Nuclear Technology), including elements of Fe, C, Cr, Ni, Mn, Mo, Si, and Ti, has been developed with a focus on reliable thermodynamic modeling of precipitate phases in AISI 316 austenitic stainless steels. The thermodynamic database was validated by comparing the calculated results with experimental data from commercial 316 austenitic steels. The developed computational thermodynamics was then coupled with precipitation kinetics simulation to understand the temporal evolution of precipitates in austenitic steels under long-term thermal aging (up to 600,000 h) at a temperature regime from 300 to 900 °C. This study discusses the effect of dislocation density and difusion coefficients on the precipitation kinetics at low temperatures, which shed a light on investigating the phase stability and transformation in austenitic steels used in light water reactors.

  5. Laser micropolishing of AISI 304 stainless steel surfaces for cleanability and bacteria removal capability

    Science.gov (United States)

    De Giorgi, Chiara; Furlan, Valentina; Demir, Ali Gökhan; Tallarita, Elena; Candiani, Gabriele; Previtali, Barbara

    2017-06-01

    In this work, laser micropolishing (LμP) was employed to reduce the surface roughness and waviness of cold-rolled AISI 304 stainless steel sheets. A pulsed fibre laser operating in the ns regime was used and the influence of laser parameters in a N2-controlled atmospheres was evaluated. In the optimal conditions, the surface remelting induced by the process allowed to reduce the surface roughness by closing cracks and defects formed during the rolling process. Other conditions that did not improve the surface quality were analysed for defect typology. Moreover, laser treatments allowed the production of more hydrophobic surfaces, and no surface chemistry modification was identified. Surface cleanability was investigated with Escherichia coli (E. coli), evaluating the number of residual bacteria adhering to the substrate after a washing procedure. These results showed that LμP is a suitable way to lower the average surface roughness by about 58% and average surface waviness by approximately 38%. The LμP process proved to be effective on the bacteria cleanability as approximately five times fewer bacteria remained on the surfaces treated with the optimized LμP parameters compared to the untreated surfaces.

  6. Ultrasonic nonlinearity of AISI316 austenitic steel subjected to long-term isothermal aging

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Won Sik; Kim, Chung Seok [Dept. of Materials Science and Engineering, Chosun University, Gwangju (Korea, Republic of)

    2014-06-15

    This study presents the ultrasonic nonlinearity of AISI316 austenitic stainless steels subjected to longterm isothermal aging. These steels are attractive materials for use in industrial mechanical structures because of their strength at high-temperatures and their chemical stability. The test materials were subjected to accelerated heat-treatment in an electrical furnace for a predetermined aging duration. The variations in the ultrasonic nonlinearity and microstructural damage were carefully evaluated through observation of the microstructure. The ultrasonic nonlinearity stiffly dropped after aging for up to 1000 h and, then, monotonously decreased. The polygonal shape of the initial grain structures changed to circular, especially as the annealing twins in the grains dissolved and disappeared. The delta ferrite on the grain boundaries could not be observed at 1000 h of aging, and these continuously transformed into their sigma phases. Consequently, in the intial aging period, the rapid decrease in the ultrasonic nonlinearity was caused by voids, dislocations, and twin annihilation. The continuous monotonic decrease in the ultrasonic nonlinearity after the first drop resulted from the generation of Cr{sub 23}C{sub 6} precipitates and σ phases.

  7. Pengaruh Media Pendingin pada Heat Treatment Terhadap Struktur Mikro dan Sifat Mekanik Friction Wedge AISI 1340

    Directory of Open Access Journals (Sweden)

    Bayu Adie Septianto

    2013-09-01

    Full Text Available Baja AISI 1340 termasuk baja paduan rendah dengan komposisi karbon 0.38-0.43% dan Mangan 1,78%. Baja ini digunakan untuk komponen kereta api Friction Wedge yang memiliki standar kekerasan minimal 300 BHN. Untuk menambah kekerasan, salah satu cara yang digunakan adalah heat treatment. Pada penelitian ini variasi yang digunakan adalah media pendingin air, oli SAE 20W, PVA 20% dan pendinginan udara pada tempertaur austenitisasi 8400C dan waktu tahan 20 menit. Kekerasan yang dihasilkan oleh media pendingin air adalah 556,6 BHN, sedangkan quench oli dan polimer 461,8 BHN dan 416 BHN. Pada pendinginan udara dihasilkan kekerasan dibawah 300 BHN. Perbedaan media pendingin berpengaruh terhadap struktur mikro yang terbentuk. Pada pendinginan dengan media air dan oli diperoleh struktur martensit dengan bentuk kristal BCT. Sedangkan pada pendinginan udara terbentuk struktur ferrit dan perlit dengan bentuk kristal BCC. Selain berpengaruh pada sifat mekanik dan struktur mikronya, variasi media pendingin juga memberikan efek terhadap sifat termalnya dan berpengaruh terhadap elongation pada temperatur maksimum kerja. Dari hasil uji TMA, performa paling baik pada temperatur 300oC dihasilkan pada pendinginan quench oli SAE 20W, dengan pertambahan panjang sebesar 0,65%.

  8. Finite Element Simulation of Residual Stresses in Butt Welding of Two AISI 304 Stainless Steel Plates

    Directory of Open Access Journals (Sweden)

    Gurinder Singh Brar

    2013-06-01

    Full Text Available Welding is one of the most reliable and efficient permanent metal joining processes in the industry. When two plates are joined by welding, a very complex thermal cycle is applied to the weldment. Thermal energy applied results in irreversible elastic-plastic deformation and consequently gives rise to the residual stresses in and around fusion zone and heat affected zone (HAZ. It is well established fact that structural integrity of components is substantially affected by the residual stresses when subjected to thermal and structural loads. Presence of residual stresses may be beneficial or harmful for the structural components depending on the nature and magnitude of residual stresses. Using finite element based commercially available software, coupled thermal-mechanical three dimensional finite element model was developed by making an approximate geometry of the butt welded joint. Finite element analysis was performed to understand the complete nature of residual stresses in manual metal arc welded joint of AISI 304 stainless steel plate. Variation of residual stress in the plates in the heat affected zone was also being studied. The results obtained by finite element method agree well with those from X-ray diffraction method as published in literature for the prediction of residual stresses.

  9. CRYOGENIC AND STRESS RELIEF THERMAL TREATMENTS IN AN AISI D2 STEEL

    Directory of Open Access Journals (Sweden)

    Paula Fernanda da Silva Farina

    2012-06-01

    Full Text Available The effects of cryogenic treatments on an AISI D2 cold work tool steel using X-ray diffraction from syncronton radiation are studied. The aim of this work is to verify the effects of: i time at cryogenic temperatures (3, 10 and 30 hours; ii cryogenic temperatures (–80°C and –196°C; iii stress relief heat treatment (130°C before cryogenic treatments; iv effect of double tempering at 520°C for 2 hours each time, after cryogenic treatment at –196°C for 30 hours, with and without previous stress relief. X-ray diffraction experiments were conducted at the line D10B-XPD of the Laboratório Nacional de Luz Síncrotron and the experimental results were treated using Rietveld refining, with TOPAS Academic in conjunction with cards from the ICCD-PDF 2006 database for austenite, martensite and carbides M7C3and M2C. Tempered samples were characterized using SEM and SEM-FEG. Volume fraction of retained austenite and carbides, as well as changes in the crystal lattices of martensite and austenite are obtained from the X-ray experiments.

  10. Surface severe plastic deformation of AISI 304 via conventional shot peening, severe shot peening and repeening

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Okan, E-mail: unalokan78@gmail.com [Mechanical Engineering Department, Bartın University, Bartın 74100 (Turkey); Varol, Remzi [Mechanical Engineering Department, Suleyman Demirel University, Isparta 32200 (Turkey)

    2015-10-01

    Highlights: • CSP and SSP treatments transform austenite to metastable martensite structure. • Nanograin layer thickness after CSP and SSP is 8 μm and 22 μm, respectively. • Shot peening leads to carbon segregation from coarse to nano grain layer. • Repeening is an effective way to reduce surface roughness. - Abstract: Air blast conventional shot peening (CSP), severe shot peening (SSP) and repeening (RP) as a severe plastic deformation applications on AISI 304 austenitic stainless steel is addressed. Shot peened specimens are investigated based on optical, FESEM and digital microscope. The investigations present the austenite transformation to metastable martensite via mechanical twinning due to plastic deformation with high strain rates. It is found that SSP induces thicker nanograin layer with compared to CSP. In XRD studies, the austenite peaks broaden by means of severe shot peening and FWHM increase reveals the grain size reduction below 25 nm regimes on the surface. In EDAX line analysis of CSP specimen, carbon content increase has been detected from deformed layer through the nanocrystalline layer then the content reduces. The carbon segregation takes place due to the energy level distinction between dislocations and Fe−C bonds. 3d contour digital microscope studies and roughness investigations reveal that SSP has deleterious side effect on the surface roughness and surface flatness. However, RP is an effective way to reduce the surface roughness to reasonable values.

  11. An experimental investigation of pulsed laser-assisted machining of AISI 52100 steel

    Science.gov (United States)

    Panjehpour, Afshin; Soleymani Yazdi, Mohammad R.; Shoja-Razavi, Reza

    2014-11-01

    Grinding and hard turning are widely used for machining of hardened bearing steel parts. Laser-assisted machining (LAM) has emerged as an efficient alternative to grinding and hard turning for hardened steel parts. In most cases, continuous-wave lasers were used as a heat source to cause localized heating prior to material removal by a cutting tool. In this study, an experimental investigation of pulsed laser-assisted machining of AISI 52100 bearing steel was conducted. The effects of process parameters (i.e., laser mean power, pulse frequency, pulse energy, cutting speed and feed rate) on state variables (i.e., material removal temperature, specific cutting energy, surface roughness, microstructure, tool wear and chip formation) were investigated. At laser mean power of 425 W with frequency of 120 Hz and cutting speed of 70 m/min, the benefit of LAM was shown by 25% decrease in specific cutting energy and 18% improvement in surface roughness, as compared to those of the conventional machining. It was shown that at constant laser power, the increase of laser pulse energy causes the rapid increase in tool wear rate. Pulsed laser allowed efficient control of surface temperature and heat penetration in material removal region. Examination of the machined subsurface microstructure and microhardness profiles showed no change under LAM and conventional machining. Continuous chips with more uniform plastic deformation were produced in LAM.

  12. Surface roughness evaluation of various cutting materials in hard turning of AISI H11

    Directory of Open Access Journals (Sweden)

    H. Aouici

    2016-04-01

    Full Text Available This paper describes a comparison of surface roughness between ceramics and cubic boron nitride (CBN7020 cutting tools when machining of AISI H11 hot work steels treated at 50 HRC. Plan is designed according to Taguchi’s L18 (21×32 orthogonal array. The response surface methodology (RSM and analysis of variance (ANOVA were used to check the validity of multiple linear regression models and to determine the effects, contribution, significance and optimal machine settings of process parameters, namely, cutting speed, feed rate and depth of cut on machining parameters on the Ra and Rt. The results of this research work showed that, the feed rate was found to be a dominant factor on the surface roughness, followed by the cutting speed, lastly the depth of cut. The CBN7020 cutting tool showed the better performance than that of ceramic based cutting tool. In addition, the combination of low feed rate and high cutting speed is necessary for minimizing the surface roughness.

  13. Implant success!!!.....simplified

    Directory of Open Access Journals (Sweden)

    Luthra Kaushal

    2009-01-01

    Full Text Available The endeavor towards life-like restoration has helped nurture new vistas in the art and science of implant dentistry. The protocol of "restoration-driven implant placement" ensures that the implant is an apical extension of the ideal future restoration and not the opposite. Meticulous pre-implant evaluation of soft and hard tissues, diagnostic cast and use of aesthetic wax-up and radiographic template combined with surgical template can simplify the intricate roadmap for appropriate implant treatment. By applying the harmony of artistic skill, scientific knowledge and clinical expertise, we can simply master the outstanding implant success in requisites of aesthetics, phonetics and function.

  14. Inflammatory responses to Hydroxyapatite implants in middle ear in rats

    Institute of Scientific and Technical Information of China (English)

    YE Qing; JIANG Yi; WANG Xiao-yan; ZHENG Ke-fei

    2008-01-01

    Objective To study local inflammatory response after implantation of hydroxyapatite synthetic ossicular prosthesis. Methods Hydroxyapatite gantries were implanted in the bulla in 32 rats. Sham surgical procedures were performed in 10 rats as the control. Animals were sacrificed at 1 to 300 days after surgery. Bulla sections, stained with HE and Mallory's azan, were examined for numbers and percentages of various inflammatory cell types. Results Slightly more inflammatory reaction was seen in animals with the implant than in the controls, mostly during the early stage following the implantation procedure. Few inflammatory cells were observed at later times. There were satisfactory fibrosis in both implanted and control ears. Conclusion The results indicate that hydroxyapatite synthetic prosthesis is a biocompatible implantation material in the middle ear. Nonetheless, the presence of inflammatory reaction immediately following implantation implies that control of infection is important in the early times after the implantation procedure.

  15. Nondestructive measurement of the residual stress TiN thin film coated on AISI 304 substrate by x-ray stress analyzer

    Science.gov (United States)

    Zhang, Y. K.; Feng, A. X.; Lu, J. Z.; Kong, D. J.; Tang, C. P.

    2006-01-01

    Titanium nitride films are deposited on AISI 304 steel with a hollow-cathode-discharge (HCD) ion-plating technique. The status of residual stresses in TiN thin film coated on AISI304 substrate by HCD is studied by x-ray diffraction stress analyzer. By analyzing morphology of the residual stress of TiN thin film at interface between TiN film and AISI 304 substrate, the adhering mechanism of TiN thin film is understood as follows: the mechanical interlocking had important contribution to the adhesion strength, the thermal stress is the major factor which resulting TiN thin film peeling off spontaneously. The results show that the value of thin film is -210MPa~-650Mpa, and the thermal stress is compressive, the intrinsic stress is tensile, origins of the residual stress are primarily discussed.

  16. Influence of sintering atmosphere on the mechanical properties of steel P / M AISI 430L; Influencia de la atmosfera de sinterizacion en las propiedades mecanicas de los aceros P/M AISI 430L

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, F. J.; Martinez, C.; Costes, M. T.; Ruiz, J. M.; Garcia, L. E.; Corpas, F.

    2014-04-01

    It has studied the stainless steel powder metallurgy AISI 430L. It has compared the sintering in two different atmospheres; in vacuum, and in an atmosphere containing nitrogen. It has developed a heat treatment with the aim of improving the mechanical properties. This has been done through microstructural modification of complex nitrides of iron and chromium precipitates during the phase of sintering. Physical properties have been evaluated and are been performing a microstructural analysis for microstructure related to the increase in mechanical properties. (Author)

  17. Dimensional characteristics of welds performed on AISI 1045 steel by means of the application of high power diode laser; Caracteristicas dimensionales de soldadura formadas sobre el acero AISI 1045 mediante la aplicacion del laser diodo de alta potencia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Castillo, A.; Pou, J.; Lusquinos, F.; Quintero, F.; Soto, R.; Boutinguiza, M.; Saavedra, M.; Perez-Amor, M.

    2004-07-01

    The named High Power diode Laser (HPDL), emits a beam of optical energy generated by diode stimulation and offers the capability of supplying levels of power up to 6 kW. The objective of this research work was to study the main welding variables and their effects on dimensional characteristics of the beads performed by means of application of this novel laser. The results obtained, show that HPDL, is an energy source able to perform welds on AISI 1045 steel plates under conduction mode, without any kind of mechanized preparation, preheating or post-weld treatment and, without filler metal application. (Author) 16 refs.

  18. Comportamiento tribológico del acero AISI W112 con endurecimiento lineal mediante laser de ND:YAG.L. // Tribological behavior of AISI W112 steel with lineal hardening by means of ND:YAG laser.

    Directory of Open Access Journals (Sweden)

    R. Sagaró

    2001-07-01

    Full Text Available Para disminuir el desgaste en los sistemas tribológicos frecuentemente se acostumbra a endurecer localmente aquellaszonas sometidas a desgaste. En el presente trabajo, para incrementar la dureza y la resistencia al desgaste del acero AISIW112 se empleó un láser de Nd:YAG. Las características de fricción y desgaste del acero AISI W112 en condiciones decontacto deslizante en fricción seca con el acero 65MN4 fueron evaluadas para tratamientos convencionales luego de suirradiación con láser. En el trabajo se presentan además las transformaciones que ocurren durante el tratamiento con láser,así como la influencia de los parámetros operacionales del láser en la profundidad de la capa endurecida y lascaracterísticas tribológicas. El trabajo experimental corroboró que la resistencia al desgaste del acero AISI W112 es variasveces superior en comparación con los tratamientos convencionales.Palabras claves: Comportamiento tribológico, endurecimiento lineal, tratamiento superficial con láser._______________________________________________________________________________Abstract.Diminishing wear in tribological systems is usually done by locally hardening those areas subject to wear. In this paper ispresented the increasing of hardness and resistance to wear of AISI W112 steel by means of a Nd:YAG laser. Thecharacteristics of friction and wear of AISI W112 steel under sliding contact in dry friction conditions with the 65MN4steel were evaluated for conventional treatments and after laser irradiation. In the work are presented the transformationsthat take place during the laser treatment, as well as the influence of the laser operational parameters in the depth of thehardened layer and the tribological characteristics. The experimental work corroborated that the resistance to wear of AISIW112 steel is several times superior in comparison with conventional treatments.Key words: Tribological behavior , lineal hardening, laser superficial

  19. The influence of cutting speed and feed rate in surface integrity of aisi 1045//Influencia de la velocidad de corte y la velocidad de avance en la integridad superficial del acero aisi 1045

    OpenAIRE

    Mario Jacas-Cabrera; Tania Rodríguez - Moliner; José Luís Lopes-Da Silveira

    2015-01-01

    El objetivo de esta investigación es el estudio de la influencia de la velocidad de corte y la velocidad de avance en la integridad superficial del acero AISI-1045, sometido a un proceso de torneado. Las probetas se sometieron a un tratamiento térmico de recocidos (81 HRB). En el trabajo se empleó un diseño experimental 32, con dos variables a tres niveles experimentales, para un total de nueve experimentos, los que fueron replicados. La integridad superficial fue evaluada con la medición de ...

  20. Comparative study of the microbiological corrosion among an AISI 304L and an API X65; Estudio comparativo de la corrosion microbiologica entre un AISI 304L y un API X65

    Energy Technology Data Exchange (ETDEWEB)

    Diaz S, A.; Arganis J, C.; Luna C, P.; Carapia M, L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gonzalez F, E. [ITT, Toluca, Estado de Mexico (Mexico)

    2004-07-01

    Metallic samples of AISI 304L sensitized and API X65, were subjected to the action of an inoculated media with reductive sulphate microorganisms (SBR), carrying out electrochemical evaluations by means of the techniques of Polarization Resistance (RP), Tafel extrapolation (ET) and Electrochemical Noise (RE). The generated information was complemented with the analysis and diagnostic of the present damage in the surfaces exposed in both metals. The used electrochemical techniques allow to determine the corrosion velocities associated to each system, establishing that the uniform corrosion is not affected by the effect of the microorganisms; however, electrochemical noise, evidenced the formation of stings associated to the presence of bacteria. (Author)

  1. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  2. Breast Implants: Saline vs. Silicone

    Science.gov (United States)

    ... differ in material and consistency, however. Saline breast implants Saline implants are filled with sterile salt water. ... of any age for breast reconstruction. Silicone breast implants Silicone implants are pre-filled with silicone gel — ...

  3. In vivo implantation of porous titanium alloy implants coated with magnesium-doped octacalcium phosphate and hydroxyapatite thin films using pulsed laser depostion.

    Science.gov (United States)

    Mróz, Waldemar; Budner, Bogusław; Syroka, Renata; Niedzielski, Kryspin; Golański, Grzegorz; Slósarczyk, Anna; Schwarze, Dieter; Douglas, Timothy E L

    2015-01-01

    The use of porous titanium-based implant materials for bone contact has been gaining ground in recent years. Selective laser melting (SLM) is a rapid prototyping method by which porous implants with highly defined external dimensions and internal architecture can be produced. The coating of porous implants produced by SLM with ceramic layers based on calcium phosphate (CaP) remains relatively unexplored, as does the doping of such coatings with magnesium (Mg) to promote bone formation. In this study, Mg-doped coatings of the CaP types octacalcium phosphate and hydroxyapatite (HA) were deposited on such porous implants using the pulsed laser deposition method. The coated implants were subsequently implanted in a rabbit femoral defect model for 6 months. Uncoated implants served as a reference material. Bone-implant contact and bone volume in the region of interest were evaluated by histopathological techniques using a tri-chromatographic Masson-Goldner staining method and by microcomputed tomography (µCT) analysis of the volume of interest in the vicinity of implants. Histopathological analysis revealed that all implant types integrated directly with surrounding bone with ingrowth of newly formed bone into the pores of the implants. Biocompatibility of all implant types was demonstrated by the absence of inflammatory infiltration by mononuclear cells (lymphocytes), neutrophils, and eosinophils. No osteoclastic or foreign body reaction was observed in the vicinity of the implants. µCT analysis revealed a significant increase in bone volume for implants coated with Mg-doped HA compared to uncoated implants.

  4. Urinary incontinence - collagen implants

    Science.gov (United States)

    ... gov/ency/article/007373.htm Urinary incontinence - injectable implant To use the sharing features on this page, please enable JavaScript. Injectable implants are injections of material into the urethra to ...

  5. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  6. About Implantable Contraception

    Science.gov (United States)

    ... a tube was inserted, and get a new contraceptive implant on schedule or switch to another method of ... continue Possible Side Effects Young women who get contraceptive implants might notice such side effects as: irregular or ...

  7. Evaluation of surgically retrieved temporomandibular joint alloplastic implants: pilot study.

    Science.gov (United States)

    Ferreira, Joao N A R; Ko, Ching-Chang; Myers, Sandra; Swift, James; Fricton, James R

    2008-06-01

    The purpose of this study was to perform a retrieval analysis of temporomandibular joint (TMJ) alloplastic interpositional implants and test possible correlation between implant failure features and patient clinical outcomes. In addition, we investigated the implants' surface and examined the foreign body reaction associated with different types of alloplastic materials. Twelve implants (Proplast/Teflon [Vitek, Houston, TX] and Silastic [Dow Corning, Midland, MI]) were surgically removed from the patients' TMJs. Implant surface failure features (fracture length, perforation of the implants) were observed using stereomicroscopy and recorded for description of the failure mechanisms and to statistically compare with clinical outcomes. Patients' clinical data (pain symptoms and mandibular function) were collected and examined. Clinical outcomes were obtained relative to symptom severity (Symptom Severity Index [SSI]) and jaw function (modified Mandibular Function Impairment Questionnaire [mMFIQ]). Peri-implant soft tissues and implants were analyzed with light microscopy and stereo zoom microscopy. Electron microprobe analysis of implant fragments and peri-implant tissues was performed. The statistical results showed that only the presence of implant perforation was statistically associated with the SSI, specifically with the pain tolerability dimension. No statistical association was seen between any of the other implant failure predictors and the SSI and between the predictors and the mMFIQ. Stereo zoom microscopy suggested that Proplast/Teflon implants (n = 7) were susceptible to perforation, layer tearing, fracture and fiber extrusion. The Silastic implants (n = 3) revealed a possible center perforation with fracture lines towards the periphery and fiber extrusion. Teflon implant wear debris particles appear to trigger a multinucleated giant cell foreign body reaction. Facial pain was a significant correlate to perforation and breakdown of the alloplastic TMJ

  8. Comparative study on structure, corrosion and hardness of Zn-Ni alloy deposition on AISI 347 steel aircraft material

    Energy Technology Data Exchange (ETDEWEB)

    Gnanamuthu, RM. [Department of Chemical Engineering, College of Engineering, Kyung Hee University, 1732 Deogyeong-daero, Gihung, Yongin, Gyeonggi 446-701 (Korea, Republic of); Mohan, S., E-mail: sanjnamohan@yahoo.com [Central Electrochemical Research Institute, (CSIR), Karaikudi 630 006, Tamilnadu (India); Saravanan, G. [Central Electrochemical Research Institute, (CSIR), Karaikudi 630 006, Tamilnadu (India); Lee, Chang Woo, E-mail: cwlee@khu.ac.kr [Department of Chemical Engineering, College of Engineering, Kyung Hee University, 1732 Deogyeong-daero, Gihung, Yongin, Gyeonggi 446-701 (Korea, Republic of)

    2012-02-05

    Highlights: Black-Right-Pointing-Pointer Electrodeposition of Zn-Ni alloy on AISI 347 steel as an aircraft material has been carried out from various baths. Black-Right-Pointing-Pointer The effect of pulse duty cycle on thickness, current efficiency and hardness reached maximum values at 40% duty cycle and for 50 Hz frequencies average current density of 4 A dm{sup -2}. Black-Right-Pointing-Pointer The XRF characterizations of 88:12% Zn-Ni alloy provided excellent corrosion resistance. Black-Right-Pointing-Pointer It is found that Zn-Ni alloy on AISI 347 aircraft material has better structure and corrosion resistance by pulse electrodeposits from electrolyte-4. - Abstract: Zn-Ni alloys were electrodeposited on AISI 347 steel aircraft materials from various electrolytes under direct current (DCD) and pulsed electrodepositing (PED) techniques. The effects of pulse duty cycle on thickness, current efficiency and hardness of electrodeposits were studied. Alloy phases of the Zn-Ni were indexed by X-ray diffraction (XRD) techniques. Microstructural morphology, topography and elemental compositions were characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM) and X-ray fluorescence spectroscopy (XRF). The corrosion resistance properties of electrodeposited Zn-Ni alloy in 3.5% NaCl aqueous solution obtained by DCD and PED were compared using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) technique. Elemental analysis showed that 88% of Zn and 12% of Ni obtained from electrolyte-4 by PED technique at 40% duty cycle for 50 Hz frequencies having better corrosion resistance than that of deposits obtained from other electrolytes.

  9. Analyses of oxide films grown on AISI 304L stainless steel and Incoloy 800HT exposed to supercritical water environment

    Energy Technology Data Exchange (ETDEWEB)

    Fulger, Manuela, E-mail: manuela.fulger@nuclear.ro [Institute for Nuclear Research Pitesti, POB 78, Campului Street, No. 1, 115400 Mioveni (Romania); Mihalache, Maria; Ohai, Dumitru [Institute for Nuclear Research Pitesti, POB 78, Campului Street, No. 1, 115400 Mioveni (Romania); Fulger, Stefan [University Politechnica Bucharest, Splaiul Independentei Street, No. 313, Bucharest 060042 (Romania); Valeca, Serban Constantin [University of Pitesti, Targul din Vale Street, No. 1, 110040 Pitesti (Romania)

    2011-08-15

    Supercritical water (SCW) is being considered as a cooling medium for the next generation nuclear reactors because it provides high thermal efficiency and plant simplification. However, materials corrosion has been identified as a critical problem due to the oxidative nature of supercritical water. Thus, for safety using of these nuclear reactor systems a systematic study of candidate materials corrosion is needed. As in other high temperature environments, corrosion in SCW occurs by the growth of an oxide layer on the materials surface. The current work aims to evaluate oxidation behavior of AISI 304L SS and Incoloy 800HT in water at supercritical temperatures in the range 723-873 K under a pressure of 25 MPa for up to 1680 h. After exposure to deaerated supercritical water, the samples were investigated using gravimetry, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and electrochemical impedance spectroscopy (EIS). Oxide films grown on these materials have a layered structure with an outer layer consisting of a mixture of iron oxide/iron-nickel spinel oxides and an inner layer consisting of chromium oxide in the case of Incoloy 800HT and nickel-chromium spinel oxide in the case of AISI 304L SS. The mass gains for Incoloy 800HT at all temperatures were small, while comparatively with AISI 304L SS which exhibited higher oxidation rates. In the same time the results obtained by EIS indicate the best corrosion resistance of oxides grown on Incoloy 800HT surface.

  10. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  11. Investigation And Optimization Of EDM Process Of AISI 4140 Alloy Steel Using Various Tool Electrodes: A Review Paper

    Directory of Open Access Journals (Sweden)

    Kishor Lal ,

    2014-11-01

    Full Text Available The purpose of this research work is to determine the optimized settings of key machining factors like pulse on time, discharge current and duty cycle for AISI 4140 alloy steel using various tool electrodes. The output responses will be measured are material removal rate (MRR,surface roughness(SR and tool wear rate(TWR. Mathematical models are proposed for the above are L27 orthogonal array. The micro structural changes in the work piece after machining process will also be examined by the use of SEM.

  12. Effect of martensite to austenite reversion on the formation of nano/submicron grained AISI 301 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Karimi, M.; Najafizadeh, A. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Kermanpur, A., E-mail: ahmad_k@cc.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Eskandari, M. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2009-11-15

    The martensite to austenite reversion behavior of 90% cold rolled AISI 301 stainless steel was investigated in order to refine the grain size. Cold rolled specimens were annealed at 600-900 deg. C, and subsequently characterized by scanning electron microscopy, X-ray diffraction, Feritscope, and hardness measurements. The effects of annealing parameters on the formation of fully-austenitic nano/submicron grained structure and the mechanisms involved were studied. It was found that annealing at 800 deg. C for 10 s exhibited the smallest average austenite grain size of 240 {+-} 60 nm with an almost fully-austenitic structure.

  13. OPTIMIZATION OF SURFACE ROUGHNESS OF AISI 304 AUSTENITIC STAINLESS STEEL IN DRY TURNING OPERATION USING TAGUCHI DESIGN METHOD

    OpenAIRE

    D. PHILIP SELVARAJ; Chandramohan, P.

    2010-01-01

    The present work is concentrated with the dry turning of AISI 304 Austenitic Stainless Steel (ASS). This paper presents the influence of cutting parameters like cutting speed, feed rate and depth of cut on the surface roughness of austenitic stainless steel during dry turning. A plan of experiments based on Taguchi’s technique has been used to acquire the data. An orthogonal array, the signal to noise (S/N) ratio and the analysis of variance (ANOVA) are employed to investigate the cutting cha...

  14. Effect of Cl– on the corrosive wear of AISI 321 stainless steel in H2SO4 solution

    Indian Academy of Sciences (India)

    Yanliang Huang; Xiaoxia Jiang; Sizuo Li

    2003-06-01

    The effect of Cl– on the corrosive wear behaviour of AISI 321 stainless steel in H2SO4 solution was studied via the corrosive wear rate, the load bearing capacity of passive film and the relationship between pitting and corrosive wear. There is a critical load at natural potential, below which the corrosive wear rate is slightly lowered by Cl–, while above which is increased. At natural potential there are more pits at low load than that at a higher one in the wear tracks and the pits are also deeper. The load bearing capacity is lowered by Cl– at passive region and then the corrosive wear rate increased.

  15. Evaluación del grado de sensibilización en el acero inoxidable AISI

    Directory of Open Access Journals (Sweden)

    González, O.

    2003-12-01

    Full Text Available Austenitic stainless steel, when heat-treated at 550-850 °C, became susceptible to intergranular corrosion in acids. This phenomenon, know as sensitization, it is result from the precipitation of chrome carbides in the grain boundary, making these areas less resistant to corrosion. Two different electrochemical reactivation tests are compared with a destructive test and related to the classification of its respective microstructures. It was established a quantitative methodology to evaluate the degree of sensitization in AISI 304 and also to compare the correspondence of the results with the data of the automatic and portable EPR device for non-destructive field measurement of the degree of sensitization. The used electrochemical techniques were the EPR (Electrochemical Potentiokinetic Reactivation or single loop test and the PRP (Pasivation Reactivation Potentiokinetic or double loop test. The destructive test used was boiling, 120 h ferric sulfate-50 % sulfuric acid, according to the standard practices ASTM A-262 practices B. The classifications of each structures were according to the standard practices ASTM A-262 practices B.

    El acero inoxidable austenítico, cuando se calienta en un rango de temperatura entre 550 y 850 °C es susceptible a corrosión intergranular en ácidos. Este fenómeno, conocido como sensibilización, es resultado de la precipitación de carburos de cromo en el límite de grano, haciendo esas áreas menos resistentes a la corrosión. Se comparan dos pruebas diferentes de reactivación electroquímica con una prueba destructiva, relacionándolas con su respectiva microestructura. Se estableció una metodología cuantitativa para evaluar el grado de sensibilización del acero AISI 304 y se comparó con los datos generados de una herramienta no destructiva de campo, automática y portátil, para medir el grado de sensibilización. Las técnicas electroquímicas usadas fueron: la EPR (Reactivación electroqu

  16. Implantable Heart Aid

    Science.gov (United States)

    1984-01-01

    CPI's human-implantable automatic implantable defibrillator (AID) is a heart assist system, derived from NASA's space circuitry technology, that can prevent erratic heart action known as arrhythmias. Implanted AID, consisting of microcomputer power source and two electrodes for sensing heart activity, recognizes onset of ventricular fibrillation (VF) and delivers corrective electrical countershock to restore rhythmic heartbeat.

  17. Recubrimientos de (ti,aln sobre acero aisi 4140 por sputtering reactivo

    Directory of Open Access Journals (Sweden)

    DANNA GARCIA

    2007-01-01

    Full Text Available Empleando la técnica de Pulverización catódica con radiofrecuencia y magnetrón (Magnetron Sputtering RF, se prepararon películas de (Ti,AlN sobre sustratos de acero AISI 4140. Se utilizó un blanco formado con polvos metálicos de Ti y Al, con composición nominal 60% Ti y 40% Al (porcentaje en átomos y una razón de presiones parciales de nitrógeno - argón, PN2/PAr de 0,1 aproximadamente; la temperatura del sustrato se varió entre 260 y 330 ºC y el tiempo de deposición entre 2 y 4,5 horas para obtener películas con diferentes espesores. La composición química de las películas se determinó mediante la técnica de energía dispersada de rayos X (EDX, y su topografía mediante microscopía de fuerza atómica (AFM. Igualmente se midió micro dureza, y se determinó su comportamiento electroquímico mediante espectroscopia de impedancia electroquímica EIS y ensayos TAFEL. Las películas obtenidas presentaron granos globulares, uniformes y de pequeño diámetro, con características electroquímicas de protección al sustrato frente a procesos de corrosión.

  18. Friction Characteristics of Nitrided Layers on AISI 430 Ferritic Stainless Steel Obtained by Various Nitriding Processes

    Directory of Open Access Journals (Sweden)

    Hakan AYDIN

    2013-03-01

    Full Text Available The influence of plasma, gas and salt-bath nitriding techniques on the friction coefficient of AISI 430 ferritic stainless steel was studied in this paper. Samples were plasma nitrided in 80 % N2 + 20 % H2 atmosphere at 450 °C and 520 °C for 8 h at a pressure of 2 mbar, gas nitrided in NH3 and CO2 atmosphere at 570 °C for 13 h and salt-bath nitrided in a cyanide-cyanate salt-bath at 570 °C for 1.5 h. Characterisation of nitrided layers on the ferritic stainless steel was carried out by means of microstructure, microhardness, surface roughness and friction coefficient measurements. Friction characteristics of the nitrided layers on the 430 steel were investigated using a ball-on-disc friction-wear tester with a WC-Co ball as the counter-body under dry sliding conditions. Analysis of wear tracks was carried out by scanning electron microscopy. Maximum hardness and maximum case depth were achieved on the plasma nitrided sample at 520 ºC for 8 h. The plasma and salt-bath nitriding techniques significantly decreased the average surface roughness of the 430 ferritic stainless steel. The friction test results showed that the salt-bath nitrided layer had better friction-reducing ability than the other nitrided layers under dry sliding conditions. Furthermore, the friction characteristic of the plasma nitrided layer at 520 ºC was better than that of the plasma nitrided layer at 450 °C.DOI: http://dx.doi.org/10.5755/j01.ms.19.1.3819

  19. Surface Texturing-Plasma Nitriding Duplex Treatment for Improving Tribological Performance of AISI 316 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Naiming Lin

    2016-10-01

    Full Text Available Surface texturing-plasma nitriding duplex treatment was conducted on AISI 316 stainless steel to improve its tribological performance. Tribological behaviors of ground 316 substrates, plasma-nitrided 316 (PN-316, surface-textured 316 (ST-316, and duplex-treated 316 (DT-316 in air and under grease lubrication were investigated using a pin-on-disc rotary tribometer against counterparts of high carbon chromium bearing steel GCr15 and silicon nitride Si3N4 balls. The variations in friction coefficient, mass loss, and worn trace morphology of the tested samples were systemically investigated and analyzed. The results showed that a textured surface was formed on 316 after electrochemical processing in a 15 wt % NaCl solution. Grooves and dimples were found on the textured surface. As plasma nitriding was conducted on a 316 substrate and ST-316, continuous and uniform nitriding layers were successfully fabricated on the surfaces of the 316 substrate and ST-316. Both of the obtained nitriding layers presented thickness values of more than 30 μm. The nitriding layers were composed of iron nitrides and chromium nitride. The 316 substrate and ST-316 received improved surface hardness after plasma nitriding. When the tribological tests were carried out under dry sliding and grease lubrication conditions, the tested samples showed different tribological behaviors. As expected, the DT-316 samples revealed the most promising tribological properties, reflected by the lowest mass loss and worn morphologies. The DT-316 received the slightest damage, and its excellent tribological performance was attributed to the following aspects: firstly, the nitriding layer had high surface hardness; secondly, the surface texture was able to capture wear debris, store up grease, and then provide continuous lubrication.

  20. Investigation of AISI 441 Ferritic Stainless Steel and Development of Spinel Coatings for SOFC Interconnect Applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhenguo; Xia, Guanguang; Wang, Chong M.; Nie, Zimin; Templeton, Joshua D.; Singh, Prabhakar; Stevenson, Jeffry W.

    2008-05-30

    As part of an effort to develop cost-effective ferritic stainless steel-based interconnects for solid oxide fuel cell (SOFC) stacks, both bare and spinel coated AISI 441 were studied in terms of metallurgical characteristics, oxidation behavior, and electrical performance. The conventional melt metallurgy used for the bulk alloy fabrication leads to significant processing cost reduction and the alloy chemistry with the presence of minor alloying additions of Nb and Ti facilitate the strengthening by precipitation and formation of Laves phase both inside grains and along grain boundaries during exposure in the intermediate SOFC operating temperature range. The Laves phase formed along the grain boundaries also ties up Si and prevents the formation of an insulating silica layer at the scale/metal interface during prolonged exposure. The substantial increase in ASR during long term oxidation due to oxide scale growth suggested the need for a conductive protection layer, which could also minimize Cr evaporation. In particular, Mn1.5Co1.5O4 based surface coatings on planar coupons drastically improved the electrical performance of the 441, yielding stable ASR values at 800ºC for over 5,000 hours. Ce-modified spinel coatings retained the advantages of the unmodified spinel coatings, and also appeared to alter the scale growth behavior beneath the coating, leading to a more adherent scale. The spinel protection layers appeared also to improve the surface stability of 441 against the anomalous oxidation that has been observed for ferritic stainless steels exposed to dual atmosphere conditions similar to SOFC interconnect environments. Hence, it is anticipated that, compared to unmodified spinel coatings, the Ce-modified coatings may lead to superior structural stability and electrical performance.