WorldWideScience

Sample records for implantable vascular access

  1. Leadless pacemaker implantation in a patient with complex congenital heart disease and limited vascular access

    Directory of Open Access Journals (Sweden)

    Paolo Ferrero

    2016-11-01

    Full Text Available Management of rhythm related issues might be particularly challenging in patients with congenital heart disease due to complex anatomy and restricted vascular access. The leadless technology appears a suitable and attractive alternative for this population. We describe a patient with single ventricle physiology who successfully underwent implantation of a leadless pacemaker.

  2. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    Science.gov (United States)

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  3. Safety and efficacy of using the Viabahn endoprosthesis for percutaneous treatment of vascular access complications after transfemoral aortic valve implantation

    DEFF Research Database (Denmark)

    De Backer, Ole; Arnous, Samer; Sandholt, Benjamin

    2015-01-01

    Vascular access complications (VACs) remain one of the biggest challenges when performing transcatheter aortic valve implantation (TAVI). This study aimed to investigate the short- and medium-term safety and efficacy of the Viabahn endoprosthesis (Gore, Flagstaff, AZ) when used to treat TAVI......-induced vascular injury. Over a 40-month period, 354 patients underwent true percutaneous transfemoral (TF)-TAVI using a CoreValve and Prostar-XL closure system; this was our study population. A VAC leading to acute intervention occurred in 72 patients (20.3%) - of these, 18 were managed by balloon angioplasty, 48...... were treated by Viabahn stenting (technical success rate 98%), and 6 needed surgical intervention. Overall, this approach resulted in a major VAC rate of 3.1% (n = 11) in our study cohort. Length of hospitalization and 30-day mortality rates were comparable in patients with a VAC treated by Viabahn...

  4. Pediatric vascular access

    International Nuclear Information System (INIS)

    Donaldson, James S.

    2006-01-01

    Pediatric interventional radiologists are ideally suited to provide vascular access services to children because of inherent safety advantages and higher success from using image-guided techniques. The performance of vascular access procedures has become routine at many adult interventional radiology practices, but this service is not as widely developed at pediatric institutions. Although interventional radiologists at some children's hospitals offer full-service vascular access, there is little or none at others. Developing and maintaining a pediatric vascular access service is a challenge. Interventionalists skilled in performing such procedures are limited at pediatric institutions, and institutional support from clerical staff, nursing staff, and technologists might not be sufficiently available to fulfill the needs of such a service. There must also be a strong commitment by all members of the team to support such a demanding service. There is a slippery slope of expected services that becomes steeper and steeper as the vascular access service grows. This review is intended primarily as general education for pediatric radiologists learning vascular access techniques. Additionally, the pediatric or adult interventional radiologist seeking to expand services might find helpful tips. The article also provides education for the diagnostic radiologist who routinely interprets radiographs containing vascular access devices. (orig.)

  5. Vascular Access in Children

    International Nuclear Information System (INIS)

    Krishnamurthy, Ganesh; Keller, Marc S.

    2011-01-01

    Establishment of stable vascular access is one of the essential and most challenging procedures in a pediatric hospital. Many clinical specialties provide vascular service in a pediatric hospital. At the top of the “expert procedural pyramid” is the pediatric interventional radiologist, who is best suited and trained to deliver this service. Growing awareness regarding the safety and high success rate of vascular access using image guidance has led to increased demand from clinicians to provide around-the-clock vascular access service by pediatric interventional radiologists. Hence, the success of a vascular access program, with the pediatric interventional radiologist as the key provider, is challenging, and a coordinated multidisciplinary team effort is essential for success. However, there are few dedicated pediatric interventional radiologists across the globe, and also only a couple of training programs exist for pediatric interventions. This article gives an overview of the technical aspects of pediatric vascular access and provides useful tips for obtaining vascular access in children safely and successfully using image guidance.

  6. Evaluation of the perceptions and cosmetic satisfaction of breast cancer patients undergoing totally implantable vascular access device (TIVAD) placement.

    Science.gov (United States)

    Liberale, Gabriel; El Houkayem, Michel; Viste, Claire; Bouazza, Fikri; Moreau, Michel; El Nakadi, Issam; Veys, Isabelle

    2016-12-01

    Totally implantable vascular access devices (TIVADs) are widely used to administer chemotherapy to cancer patients. While great progress has been made with respect to breast surgical reconstruction to take into account both aesthetics and patients' perceptions of body integrity, these aspects have not been considered with regard to the impact of TIVAD. In order to address this practice gap, we have adapted our TIVAD implantation technique to improve cosmetic results. The aim of this study was to assess breast cancer patients' comfort level and aesthetic satisfaction with regard to TIVAD insertion. Patients with breast cancer admitted for chemotherapy at an outpatient clinic completed a previously validated survey evaluating three main domains: symptoms (pain, discomfort) related to the TIVAD itself in daily activity, information received before and during the surgical procedure, and cosmetic aspects regarding the port insertion site (scar, port, and catheter location). Between September 2010 and June 2011, 232 patients were evaluated. Cosmetic satisfaction with scar location was high (93.3 %). Information given to patients before and during the procedure had a major impact on both symptom perception in daily activity and on cosmetic satisfaction. Obtaining a more aesthetic scar by placing the TIVAD in the deltopectoral groove contributed to a high rate of cosmetic satisfaction. Furthermore, the relevance of information given to patients before and/or during surgery had a major impact on symptom perception. Therefore, we suggest including a pre-operative information session in the care pathway.

  7. [Vascular access guidelines for hemodialysis].

    Science.gov (United States)

    Rodríguez Hernández, J A; González Parra, E; Julián Gutiérrez, J M; Segarra Medrano, A; Almirante, B; Martínez, M T; Arrieta, J; Fernández Rivera, C; Galera, A; Gallego Beuter, J; Górriz, J L; Herrero, J A; López Menchero, R; Ochando, A; Pérez Bañasco, V; Polo, J R; Pueyo, J; Ruiz, Camps I; Segura Iglesias, R

    2005-01-01

    Quality of vascular access (VA) has a remarkable influence in hemodialysis patients outcomes. Dysfunction of VA represents a capital cause of morbi-mortality of these patients as well an increase in economical. Spanish Society of Neprhology, aware of the problem, has decided to carry out a revision of the issue with the aim of providing help in comprehensión and treatment related with VA problems, and achieving an homogenization of practices in three mayor aspects: to increase arteriovenous fistula utilization as first vascular access, to increment vascular access monitoring practice and rationalise central catheters use. We present a consensus document elaborated by a multidisciplinar group composed by nephrologists, vascular surgeons, interventional radiologysts, infectious diseases specialists and nephrological nurses. Along six chapters that cover patient education, creation of VA, care, monitoring, complications and central catheters, we present the state of the art and propose guidelines for the best practice, according different evidence based degrees, with the intention to provide help at the professionals in order to make aproppiate decissions. Several quality standars are also included.

  8. Vascular access for home haemodialysis.

    Science.gov (United States)

    Al Shakarchi, Julien; Day, C; Inston, N

    2018-03-01

    Home haemodialysis has been advocated due to improved quality of life. However, there are very little data on the optimum vascular access for it. A retrospective cohort study was carried on all patients who initiated home haemodialysis between 2011 and 2016 at a large university hospital. Access-related hospital admissions and interventions were used as primary outcome measures. Our cohort consisted of 74 patients. On initiation of home haemodialysis, 62 individuals were using an arteriovenous fistula as vascular access, while the remaining were on a tunnelled dialysis catheter. Of the 12 patients who started on a tunnelled dialysis catheter, 5 were subsequently converted to either an arteriovenous fistula ( n = 4) or an arteriovenous graft ( n = 1). During the period of home haemodialysis use, four arteriovenous fistula failed or thrombosed with patients continuing on home haemodialysis using an arteriovenous graft ( n = 3) or a tunnelled dialysis catheter ( n = 1). To maintain uninterrupted home haemodialysis, interventional rates were 0.32 per arteriovenous fistula/arteriovenous graft access-year and 0.4 per tunnelled dialysis catheter access-year. Hospital admission rates for patients on home haemodialysis were 0.33 per patient-year. Our study has shown that home haemodialysis can be safely and independently performed at home within a closely managed home haemodialysis programme. The authors also advocate the use of arteriovenous fistulas for this cohort of patients due to both low complication and intervention rates.

  9. ESRD QIP - Vascular Access - Payment Year 2018

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes facility details, performance rates, vascular access topic measure score, and the state and national average measure scores for the vascular...

  10. Features and selection of vascular access devices.

    Science.gov (United States)

    Sansivero, Gail Egan

    2010-05-01

    To review venous anatomy and physiology, discuss assessment parameters before vascular access device (VAD) placement, and review VAD options. Journal articles, personal experience. A number of VAD options are available in clinical practice. Access planning should include comprehensive assessment, with attention to patient participation in the planning and selection process. Careful consideration should be given to long-term access needs and preservation of access sites. Oncology nurses are uniquely suited to perform a key role in VAD planning and placement. With knowledge of infusion therapy, anatomy and physiology, device options, and community resources, nurses can be key leaders in preserving vascular access and improving the safety and comfort of infusion therapy. Copyright 2010 Elsevier Inc. All rights reserved.

  11. [Thrombosis in vascular accesses for haemodialysis: rescue treatment using invasive vascular radiological techniques].

    Science.gov (United States)

    García Medina, J; Lacasa Pérez, N; Muray Cases, S; Pérez Garrido, I; García Medina, V

    2009-01-01

    The purpose of this paper is to communicate our experience in the salvage of thrombosed haemodialysis vascular accesses using interventional radiology techniques. In the last four years, we have treated, by radiological means, 101 thrombosed haemodialysis vascular accesses. There were 44 autologous arteriovenous fistulas (43.56%) and 57 PTFE grafts (56.44%). There were 69 men (68.3%) and 32 women (31.7%). The mean age was 67.73 years (range 33-84). The mean vascular access age was 23.79 months (range 1-132). Manual catheter-directed aspiration was used. Fragmented, triturated or pushed the thrombus against the pulmonary circulation was avoided in all cases. 78 accesses were salvaged (77.2%). Autologous fistulas average and PTFE grafts success rate were 84.44% and 71.42% respectively. Angioplasty in one or more lesions after thromboaspiration was performed in all accesses, except six (5.9%). Metallic endoprostheses were implanted in 14 accesses (13.9%). Mean follow-up was 9 months (range 0-44). Primary patency was 42.3% +/- 5 at 6 months and 32% +/- 4 at one year. Autologous fistulas patency was better than PTFE grafts patency (p better than PTFE grafts. This justifies interventional radiology techniques in these situations.

  12. Bioresorbable vascular scaffold (BVS) for in-stent chronic total occlusion: Antegrade recanalization and IVUS-guided BVS implantation by radial access

    Energy Technology Data Exchange (ETDEWEB)

    Medda, Massimo [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Casilli, Francesco, E-mail: frcasill@tin.it [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Bande, Marta [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Latini, Maria Giulia [Cardiologia Interventistica, IRCCS Policlinico San Donato, San Donato Milanese, Milano (Italy); Ghommidh, Mehdi [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Del Furia, Francesca [Unità Operativa di Cardiologia, Azienda Ospedaliera di Melegnano, Milano (Italy); Inglese, Luigi [Interventistica Cardiovascolare, Gruppo Sanitario Policlinico di Monza, Milano (Italy)

    2016-01-15

    The completely absorbable stents represent one of the latest innovations in the field of interventional cardiology, prospecting the possibility of “vascular repair”. In the published trials (ABSORB Cohort A and B, ABSORB EXTEND, and ABSORB II, III and IV) chronic total occlusions (CTOs) were considered an exclusion criteria. More recently the CTO-ABSORB pilot study demonstrated the safety and feasibility of bioresorbable vascular scaffold (BVS) use in case of CTO recanalization. We present the first case, to our knowledge, of in-stent occlusion successfully treated with an everolimus-eluting BVS and discuss its potential advantages in such kind of lesions.

  13. Bioresorbable vascular scaffold (BVS) for in-stent chronic total occlusion: Antegrade recanalization and IVUS-guided BVS implantation by radial access

    International Nuclear Information System (INIS)

    Medda, Massimo; Casilli, Francesco; Bande, Marta; Latini, Maria Giulia; Ghommidh, Mehdi; Del Furia, Francesca; Inglese, Luigi

    2016-01-01

    The completely absorbable stents represent one of the latest innovations in the field of interventional cardiology, prospecting the possibility of “vascular repair”. In the published trials (ABSORB Cohort A and B, ABSORB EXTEND, and ABSORB II, III and IV) chronic total occlusions (CTOs) were considered an exclusion criteria. More recently the CTO-ABSORB pilot study demonstrated the safety and feasibility of bioresorbable vascular scaffold (BVS) use in case of CTO recanalization. We present the first case, to our knowledge, of in-stent occlusion successfully treated with an everolimus-eluting BVS and discuss its potential advantages in such kind of lesions.

  14. Vascular access: a never-ending story.

    Science.gov (United States)

    Hedin, U

    2014-12-01

    Vascular surgeons are more and more becoming responsible for "life-line" creation well functioning and maintenance of hemodialysis patients and to provide a well functioning and multidisciplinary access service together with nefrologists, dialysis staff, and interventional radiology. For many, this sometimes arduous surgery with associated complicated clinical decision making, becomes a constant and challenging burden but much through the appearance of national and international guidelines and especially the endovascular technology, feasible solutions are easily at hand and the life as an access surgeon more pleasant. Here, basics in dialysis access care are presented together with some examples of novel available solutions to troublesome clinical problems.

  15. Maintenance of vascular access patency in pediatrics

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Wyly, J.B.; Fellows, K.E.; Harmon, W.; Levey, R.H.

    1986-01-01

    The patency of vascular access shunts and fistulae has been prolonged by a combined surgical and radiological approach that includes percutaneous transluminal angioplasty (PTA), surgical revision, thrombectomy, and thrombolysis. Over the last 3 years, 35 vascular accesses in 27 patients were found to have angiographic abnormality. PTA was performed 32 times of 19 accesses and 7 PTAs resulted in patent accesses by the end of the study. Surgical revision was performed 9 times on 8 accesses and 2 of the surgical revisions resulted in a patent access by the end of the study. Concerning Thomas femoral shunts, PTA prolonged the patency by 2.2 months and surgical revision by 3.8 months per procedure. Concerning arteriovenous (AV) fistulae, PTA prolonged the patency by 4.3 months and surgical revision by 3.5 months per procedure. A combination of procedures effectively doubles the duration of patency of Thomas femoral shunts and almost triples the duration of patency of AV fistulae in children. Forty-one percent of these accesses remain open 1 year following the initiation of these procedures. (orig.)

  16. Revascularization of diaphyseal bone segments by vascular bundle implantation.

    Science.gov (United States)

    Nagi, O N

    2005-11-01

    Vascularized bone transfer is an effective, established treatment for avascular necrosis and atrophic or infected nonunions. However, limited donor sites and technical difficulty limit its application. Vascular bundle transplantation may provide an alternative. However, even if vascular ingrowth is presumed to occur in such situations, its extent in aiding revascularization for ultimate graft incorporation is not well understood. A rabbit tibia model was used to study and compare vascularized, segmental, diaphyseal, nonvascularized conventional, and vascular bundle-implanted grafts with a combination of angiographic, radiographic, histopathologic, and bone scanning techniques. Complete graft incorporation in conventional grafts was observed at 6 months, whereas it was 8 to 12 weeks with either of the vascularized grafts. The pattern of radionuclide uptake and the duration of graft incorporation between vascular segmental bone grafts (with intact endosteal blood supply) and vascular bundle-implanted segmental grafts were similar. A vascular bundle implanted in the recipient bone was found to anastomose extensively with the intraosseous circulation at 6 weeks. Effective revascularization of bone could be seen when a simple vascular bundle was introduced into a segment of bone deprived of its normal blood supply. This simple technique offers promise for improvement of bone graft survival in clinical circumstances.

  17. [The Carboclip, a new, atraumatic vascular access for hemodialysis].

    Science.gov (United States)

    Bonnaud, P; Jehenne, G; Man, N K

    1994-01-01

    The Carboclip is a no-needle vascular access device made of an inverted Titanium body. The horizontal bar of 6 mm inner diameter is connected with artery and vein via a vascular graft. The vertical body houses an elastic plug in which is inserted a double canula diving in the blood stream for extracorporeal blood circulation (EBC). The body is wrapped by a flange made of microporous biocarbon in which the subcutaneous fibroblast will growth, forming an antimicrobial barrier and fixing the port to the skin. We report our experience on 30 devices implanted in 30 sheep with 26 extracorporeal circulation simulating hemodialysis. The results demonstrate good tightness of the plug as well at rest as during EBC procedure, sufficient blood flow rate of about 400 ml/min, and benefits of the microporous carbon flange.

  18. Future Trends in Vascular Access Creation.

    Science.gov (United States)

    Shenoy, Surendra

    2017-01-01

    Delivery of a prescribed dialysis dose, which is critical for longevity on hemodialysis, is directly dependent on vascular access (VA). However, VA is fraught with high failure rates and has room for innovation. Arteriovenous fistula (AVF), considered the 'best choice', has a high 'failure to mature' rate. Arteriovenous grafts (AVGs) are considered when patients are poor candidates for or have failed AVF, but have a high incidence of infections and thrombosis. Due to associated morbidity and mortality from complications, central venous catheters are considered only as 'bridging short-term access' when there is an urgent need for dialysis. The observation from current data that there is a significant center effect in the rate of AVF maturation supports investigation to identify factors that contribute to success in high-performing centers that create AVF and establish 'best practice' approaches to improve outcomes. Biocompatible AVG constructs that promote rapid tissue incorporation withstand needle punctures due to better integrity and can improve current AVG outcomes. Stenosis in the 'access circuit' is a major cause for short- and long-term permanent access failure. While the pathology of stenosis development is well understood, factors responsible for this problem are poorly studied. Increased flow in the access circuit likely plays a major role in the development of such stenosis. Investigation into understanding the hemodynamics of this flow may help identify etiology and stenosis sites perhaps even prior to the event, thus providing potential targets to mitigate the stenotic response. In summary, this chapter reflects on the shortcomings of current access modalities and discusses potential avenues to improve VA outcomes in the future. © 2017 S. Karger AG, Basel.

  19. Vascular access in pediatric patients in the emergency department: types of access, indications, and complications [digest].

    Science.gov (United States)

    Whitney, Rachel; Langhan, Melissa; Pade, Kathryn H

    2017-06-22

    Vascular access is a potentially life-saving procedure that is a mainstay of emergency medicine practice. There are a number of challenges associated with obtaining and maintaining vascular access, and the choice of the route of access and equipment used will depend on patient- and provider-specific factors. In this issue, the indications and complications of peripheral intravenous access, intraosseous access, and central venous access are reviewed. Timely and effective assessment and management of difficult-access patients, pain control techniques that can assist vascular access, and contraindications to each type of vascular access are also discussed. [Points & Pearls is a digest of Pediatric Emergency Medicine Practice].

  20. Biomaterials Used in Injectable Implants (Liquid Embolics) for Percutaneous Filling of Vascular Spaces

    International Nuclear Information System (INIS)

    Jordan, Olivier; Doelker, Eric; Ruefenacht, Daniel A.

    2005-01-01

    The biomaterials currently used in injectable implants (liquid embolics) for minimally invasive image-guided treatment of vascular lesions undergo, once injected in situ, a phase transition based on a variety of physicochemical principles. The mechanisms leading to the formation of a solid implant include polymerization, precipitation and cross-linking through ionic or thermal process. The biomaterial characteristics have to meet the requirements of a variety of treatment conditions. The viscosity of the liquid is adapted to the access instrument, which can range from 0.2 mm to 3 mm in diameter and from a few centimeters up to 200 cm in length. Once such liquid embolics reach the vascular space, they are designed to become occlusive by inducing thrombosis or directly blocking the lesion when hardening of the embolics occurs. The safe delivery of such implants critically depends on their visibility and their hardening mechanism. Once delivered, the safety and effectiveness issues are related to implant functions such as biocompatibility, biodegradability or biomechanical properties. We review here the available and the experimental products with respect to the nature of the polymer, the mechanism of gel cast formation and the key characteristics that govern the choice of effective injectable implants

  1. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    Science.gov (United States)

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  2. Vascular access complications and risk factors in hemodialysis ...

    African Journals Online (AJOL)

    Vascular access complications and risk factors in hemodialysis patients: A single center study. ... Stenosis was the most common risk factor for vascular failure as it occurred in (29%) of patients. ... Other risk factors for dialysis CRBSI include older age, low serum albumin, high BUN and decreasing the duration of dialysis.

  3. Peripheral arteriovenous fistula as vascular access for long-term chemotherapy.

    Science.gov (United States)

    Kovalyov, Oleksiy O; Kostyuk, Oleksandr G; Tkachuk, Tetyana V

    To provide long-term vascular access in clinical oncology peripheral forearm veins (up to 95% of patients in Ukraine), central venous access and "complete implanted vascular systems" are used most often. Many oncology patients have contraindications to catheterization of superior vena cava. Besides, exploitation of central veins is associated with potential technical and infectious complications. The aim - to study short-term and long-term results of arteriovenous fistula exploitation as vascular access for continuous anticancer therapy. Peripheral venous bed status in 41 oncology patients taking long-term chemotherapy treatment is analyzed in the article. Doppler sonography, morphologic and immune histochemical analyses were used in the study. Doppler sonography found qualitative and quantitative changes in forearm veins at different time periods after initiation of chemotherapy in the majority of patients. The major morphologic manifestations of venous wall damage were chemical phlebitis, local or extended hardening of venous wall, venous thrombosis and extravasations with necrosis and subsequent paravasal tissue sclerosis. Alternative vascular access created in 12 patients completely met the adequacy criteria (safety, multiple use, longevity, realization of the designed therapy program). The conclusion was made about inapplicability of forearm veins for long-term administration of cytostatic agents. If it is impossible to use central veins, arteriovenous fistula can become an alternative vascular access.

  4. Disruptive technological advances in vascular access for dialysis: an overview.

    Science.gov (United States)

    Yeo, Wee-Song; Ng, Qin Xiang

    2017-11-29

    End-stage kidney disease (ESKD), one of the most prevalent diseases in the world and with increasing incidence, is associated with significant morbidity and mortality. Current available modes of renal replacement therapy (RRT) include dialysis and renal transplantation. Though renal transplantation is the preferred and ideal mode of RRT, this modality may not be available to all patients with ESKD. Moreover, renal transplant recipients are constantly at risk of complications associated with immunosuppression and immunosuppressant use, and posttransplant lymphoproliferative disorder. Dialysis may be the only available modality in certain patients. However, dialysis has its limitations, which include issues associated with lack of vascular access, risks of infections and vascular thrombosis, decreased quality of life, and absence of biosynthetic functions of the kidney. In particular, the creation and maintenance of hemodialysis vascular access in children poses a unique set of challenges to the pediatric nephrologist owing to the smaller vessel diameters and vascular hyperreactivity compared with adult patients. Vascular access issues continue to be one of the major limiting factors prohibiting the delivery of adequate dialysis in ESKD patients and is the Achilles' heel of hemodialysis. This review aims to provide a critical overview of disruptive technological advances and innovations for vascular access. Novel strategies in preventing neointimal hyperplasia, novel bioengineered products, grafts and devices for vascular access will be discussed. The potential impact of these solutions on improving the morbidity encountered by dialysis patients will also be examined.

  5. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  6. Evaluation of ultrasound-guided vascular access in dogs.

    Science.gov (United States)

    Chamberlin, Scott C; Sullivan, Lauren A; Morley, Paul S; Boscan, Pedro

    2013-01-01

    To describe the technique and determine the feasibility, success rate, perceived difficulty, and time to vascular access using ultrasound guidance for jugular vein catheterization in a cardiac arrest dog model. Prospective descriptive study. University teaching hospital. Nine Walker hounds. A total of 27 jugular catheterizations were performed postcardiac arrest using ultrasound guidance. Catheterizations were recorded based on the order in which they were performed and presence/absence of a hematoma around the vein. Time (minutes) until successful vascular access and perceived difficulty in achieving vascular access (scale of 1 = easy to 10 = difficult) were recorded for each catheterization. Mean time to vascular access was 1.9 minutes (95% confidence interval, 1.1-3.4 min) for catheterizations without hematoma, versus 4.3 minutes (1.8-10.1 min) for catheterizations with hematoma (P = 0.1). Median perceived difficulty was 2 of 10 (range 1-7) for catheterizations without hematoma, versus 2 of 10 (range 1-8) for catheterizations with hematoma (P = 0.3). A learning curve was evaluated by comparing mean time to vascular access and perceived difficulty in initial versus subsequent catheterizations. Mean time to vascular access was 2.5 minutes (1.0-6.4 min) in the initial 13 catheterizations versus 3.3 minutes (1.5-7.5 min) in the subsequent 14 catheterizations (P = 0.6). Median perceived difficulty in the first 13 catheterizations (3, range 1-8) was significantly greater (P = 0.049) than median perceived difficulty in the subsequent 14 catheterizations (2, range 1-6). Ultrasound-guided jugular catheterization is associated with a learning curve but is successful in obtaining rapid vascular access in dogs. Further prospective studies are warranted to confirm the utility of this technique in a clinical setting. © Veterinary Emergency and Critical Care Society 2013.

  7. Spanish Clinical Guidelines on Vascular Access for Haemodialysis.

    Science.gov (United States)

    Ibeas, José; Roca-Tey, Ramon; Vallespín, Joaquín; Moreno, Teresa; Moñux, Guillermo; Martí-Monrós, Anna; Del Pozo, José Luis; Gruss, Enrique; Ramírez de Arellano, Manel; Fontseré, Néstor; Arenas, María Dolores; Merino, José Luis; García-Revillo, José; Caro, Pilar; López-Espada, Cristina; Giménez-Gaibar, Antonio; Fernández-Lucas, Milagros; Valdés, Pablo; Fernández-Quesada, Fidel; de la Fuente, Natalia; Hernán, David; Arribas, Patricia; Sánchez de la Nieta, María Dolores; Martínez, María Teresa; Barba, Ángel

    2017-11-01

    Vascular access for haemodialysis is key in renal patients both due to its associated morbidity and mortality and due to its impact on quality of life. The process, from the creation and maintenance of vascular access to the treatment of its complications, represents a challenge when it comes to decision-making, due to the complexity of the existing disease and the diversity of the specialities involved. With a view to finding a common approach, the Spanish Multidisciplinary Group on Vascular Access (GEMAV), which includes experts from the five scientific societies involved (nephrology [S.E.N.], vascular surgery [SEACV], vascular and interventional radiology [SERAM-SERVEI], infectious diseases [SEIMC] and nephrology nursing [SEDEN]), along with the methodological support of the Cochrane Center, has updated the Guidelines on Vascular Access for Haemodialysis, published in 2005. These guidelines maintain a similar structure, in that they review the evidence without compromising the educational aspects. However, on one hand, they provide an update to methodology development following the guidelines of the GRADE system in order to translate this systematic review of evidence into recommendations that facilitate decision-making in routine clinical practice, and, on the other hand, the guidelines establish quality indicators which make it possible to monitor the quality of healthcare. Copyright © 2017 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Vascular access in critical limb ischemia.

    Science.gov (United States)

    Kang, Won Yu; Campia, Umberto; Ota, Hideaki; Didier, Romain J; Negi, Smita I; Kiramijyan, Sarkis; Koifman, Edward; Baker, Nevin C; Magalhaes, Marco A; Lipinski, Michael J; Escarcega, Ricardo O; Torguson, Rebecca; Waksman, Ron; Bernardo, Nelson L

    2016-01-01

    Currently, percutaneous endovascular intervention is considered a first line of therapy for treating patients with critical limb ischemia. As the result of remarkable development of techniques and technologies, percutaneous endovascular intervention has led to rates of limb salvage comparable to those achieved with bypass surgery, with fewer complications, even in the presence of lower rates of long-term patency. Currently, interventionalists have a multiplicity of access routes including smaller arteries, with both antegrade and retrograde approaches. Therefore, the choice of the optimal access site has become an integral part of the success of the percutaneous intervention. By understanding the technical aspects, as well as the advantages and limitations of each approach, the interventionalists can improve clinical outcomes in patients with severe peripheral arterial disease. This article reviews the access routes in critical limb ischemia, their advantages and disadvantages, and the clinical outcomes of each. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Surveillance of Hemodialysis Vascular Access with Ultrasound Vector Flow Imaging

    DEFF Research Database (Denmark)

    Brandt, Andreas Hjelm; Olesen, Jacob Bjerring; Lindskov Hansen, Kristoffer

    2015-01-01

    -functioning vascular access with as few complications as possible and preferred vascular access is an AVF. Dysfunction due to stenosis is a common complication, and regular monitoring of volume flow is recommended to preserve AVF patency. UDT is considered the gold standard for volume flow surveillance, but VFI has...... proven to be more precise, when performing single repeated instantaneous measurements. Three patients with AVF were monitored with UDT and VFI monthly for five months. A commercial ultrasound scanner with a 9 MHz linear array transducer with integrated VFI was used to obtain data. UDT values were...... be used for surveillance of volume flow....

  10. The Biocarbon vascular access device (DiaTAB) for haemodialysis.

    Science.gov (United States)

    Smits, P J; Slooff, M J; Lichtendahl, D H; van der Hem, G K

    1985-01-01

    The Biocarbon vascular access device (DiaTAB) is a relatively new method in secondary access surgery. Punctures, often the cause of complications can be avoided because it is a no-needle method of dialysis. However thrombosis due to stenosis of the venous anastomosis or of the efferent vein is a continuing problem. A new experience is the fibrin flap formation under the plug of the device, which can be removed easily.

  11. The effect of lowering LDL cholesterol on vascular access patency

    DEFF Research Database (Denmark)

    Herrington, William; Emberson, Jonathan; Staplin, Natalie

    2014-01-01

    BACKGROUND AND OBJECTIVES: Reducing LDL cholesterol (LDL-C) with statin-based therapy reduces the risk of major atherosclerotic events among patients with CKD, including dialysis patients, but the effect of lowering LDL-C on vascular access patency is unclear. DESIGN, SETTING, PARTICIPANTS...

  12. Use of vascular access for haemodialysis in Europe

    DEFF Research Database (Denmark)

    Noordzij, Marlies; Jager, Kitty J; van der Veer, Sabine N

    2014-01-01

    BACKGROUND: Although arteriovenous fistulas (AVFs) are actively promoted, their use at the start of haemodialysis (HD) seems to be decreasing worldwide. In this paper, we describe recent trends in incidence and prevalence of vascular access types in Europe from 2005 to 2009 and their relationship...

  13. Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries

    Directory of Open Access Journals (Sweden)

    Charanpreet Singh

    2015-06-01

    Full Text Available Vascular implants belong to a specialised class of medical textiles. The basic purpose of a vascular implant (graft and stent is to act as an artificial conduit or substitute for a diseased artery. However, the long-term healing function depends on its ability to mimic the mechanical and biological behaviour of the artery. This requires a thorough understanding of the structure and function of an artery, which can then be translated into a synthetic structure based on the capabilities of the manufacturing method utilised. Common textile manufacturing techniques, such as weaving, knitting, braiding, and electrospinning, are frequently used to design vascular implants for research and commercial purposes for the past decades. However, the ability to match attributes of a vascular substitute to those of a native artery still remains a challenge. The synthetic implants have been found to cause disturbance in biological, biomechanical, and hemodynamic parameters at the implant site, which has been widely attributed to their structural design. In this work, we reviewed the design aspect of textile vascular implants and compared them to the structure of a natural artery as a basis for assessing the level of success as an implant. The outcome of this work is expected to encourage future design strategies for developing improved long lasting vascular implants.

  14. Vascular access surveillance: case study of a false paradigm.

    Science.gov (United States)

    Paulson, William D; Moist, Louise; Lok, Charmaine E

    2013-01-01

    The hemodialysis vascular access surveillance controversy provides a case study of how enthusiasm for a new test or treatment can lead to adoption of a false paradigm. Paradigms are the beliefs and assumptions shared by those in a field of knowledge, and are commonly included in clinical practice guidelines. The guidelines of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommend that arteriovenous vascular accesses undergo routine surveillance for detection and correction of stenosis. This recommendation is based on the paradigm that surveillance of access blood flow or dialysis venous pressure combined with correction of stenosis improves access outcomes. However, the quality of evidence that supports this paradigm has been widely criticized. We tested the validity of the surveillance paradigm by applying World Health Organization (WHO) criteria for evaluating screening tests to a literature review of published vascular access studies. These criteria include four components: undesired condition, screening test, intervention, and desired outcome. The WHO criteria show that surveillance as currently practiced fails all four components and provides little or no significant benefit, suggesting that surveillance is a false paradigm. Once a paradigm is established, however, challenges to its validity are usually resisted even as new evidence indicates the paradigm is not valid. Thus, it is paramount to apply rigorous criteria when developing guidelines. Regulators may help promote needed changes in paradigms when cost and safety considerations coincide. © 2013 Wiley Periodicals, Inc.

  15. Vascular access choice in incident hemodialysis patients: a decision analysis.

    Science.gov (United States)

    Drew, David A; Lok, Charmaine E; Cohen, Joshua T; Wagner, Martin; Tangri, Navdeep; Weiner, Daniel E

    2015-01-01

    Hemodialysis vascular access recommendations promote arteriovenous (AV) fistulas first; however, it may not be the best approach for all hemodialysis patients, because likelihood of successful fistula placement, procedure-related and subsequent costs, and patient survival modify the optimal access choice. We performed a decision analysis evaluating AV fistula, AV graft, and central venous catheter (CVC) strategies for patients initiating hemodialysis with a CVC, a scenario occurring in over 70% of United States dialysis patients. A decision tree model was constructed to reflect progression from hemodialysis initiation. Patients were classified into one of three vascular access choices: maintain CVC, attempt fistula, or attempt graft. We explicitly modeled probabilities of primary and secondary patency for each access type, with success modified by age, sex, and diabetes. Access-specific mortality was incorporated using preexisting cohort data, including terms for age, sex, and diabetes. Costs were ascertained from the 2010 USRDS report and Medicare for procedure costs. An AV fistula attempt strategy was found to be superior to AV grafts and CVCs in regard to mortality and cost for the majority of patient characteristic combinations, especially younger men without diabetes. Women with diabetes and elderly men with diabetes had similar outcomes, regardless of access type. Overall, the advantages of an AV fistula attempt strategy lessened considerably among older patients, particularly women with diabetes, reflecting the effect of lower AV fistula success rates and lower life expectancy. These results suggest that vascular access-related outcomes may be optimized by considering individual patient characteristics. Copyright © 2015 by the American Society of Nephrology.

  16. Frequency of nursing care of vascular access in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Iman Taghizade Firoozjayi

    2016-03-01

    Full Text Available Background: Hemodialysis is a critical treatment method, which depends on the vascular access route. Lack of care for the vascular access route could diminish its efficiency in a short time. Regarding this, the present study aimed to evaluate the frequency of nursing care for vascular access route in the hemodialysis patients. Methods: This cross-sectional study was conducted on 20 nurses and 120 hemodialysis patients, who referred to the Hemodialysis Department of Shahid Beheshti Hospital, Babol, Iran, in 2015. The method of nursing care for vascular access route was evaluated using a researcher-made checklist. The data analysis was performed using the descriptive statistics in the SPSS version 16. Results: In total, 14 cases of nursing care were evaluated, in 100% of which all the caring steps, including wearing gloves and a mask, early bolus injections of heparin, washing the catheter tubing, frequent monitoring of blood pressure, rinsing the catheter tubing, returning the blood to the body after hemodialysis, and sterile covering of the puncture site, were observed. However, some of the other techniques, such as the care related to appropriate pump speed when starting the dialysis machine (81.66%, observance of the needle distance from fistula (75.83%, appropriate placement of catheter (75%, pressing the injection site (54.17%, blood pressure monitoring at the end of dialysis (50%, and change of the needle site between two sessions (27.5%, were not adhered to by the nurses. Conclusion: According to the results of this study, some of the nursing care steps, which are necessary in the beginning and end of the hemodialysis, were not accurately followed by the nurses. It is recommended that constant training courses be held for the nurses in this regard.

  17. Complications of Central Venous Totally Implantable Access Port: Internal Jugular Versus Subclavian Access

    Directory of Open Access Journals (Sweden)

    Pil Young Jung

    Full Text Available Background: Totally implantable access port (TIAP provides reliable, long term vascular access with minimal risk of infection and allows patients normal physical activity. With wide use of ports, new complications have been encountered. We analyzed TIAP related complications and evaluated the outcomes of two different percutaneous routes of access to superior vena cava. Methods: All 172 patients who underwent port insertion with internal jugular approach (Group 1, n = 92 and subclavian approach (Group 2, n = 79 between August 2011 and May 2013 in a single center were analyzed, retrospectively. Medical records were analyzed to compare the outcomes and the occurrence of port related complications between two different percutaneous routes of access to superior vena cava. Results: Median follow-up for TIAP was 278 days (range, 1-1868. Twenty four complications were occurred (14.0%, including pneumothorax (n = 1, 0.6%, migration/malposition (n = 4, 2.3%, pinch-off syndrome (n = 4, 2.3%, malfunction (n = 2, 1.1%, infection (n = 8, 4.7%, and venous thrombosis (n = 5, 2.9%. The overall incidence was 8.7% and 20.3% in each group (p = 0.030. Mechanical complications except infectious and thrombotic complications were more often occurred in group 2 (p = 0.033. The mechanical complication free probability is significantly higher in group 1 (p = 0.040. Conclusions: We suggest that the jugular access should be chosen in patients who need long term catheterization because of high incidence of mechanical complication, such as pinch-off syndrome.

  18. Intramuscular ketamine to facilitate pediatric central vascular access.

    Science.gov (United States)

    Denmark, T Kent; Hargrove, Jenny R; Brown, Lance

    2004-07-01

    Obtaining prompt vascular access in young children presenting to the emergency department (ED) is frequently both necessary and technically challenging. The objective of our study was to describe our experience using intramuscular (IM) ketamine to facilitate the placement of central venous catheters in children presenting to our ED needing vascular access in a timely fashion. We performed a retrospective medical record review of all pediatric patients central venous catheter facilitated by the use of IM ketamine. Eleven children met our inclusion criteria. Most of the children were young and medically complicated. The children ranged in age from 6 months to 8 years. The only complication identified was vomiting experienced by an 8-year-old boy. Emergency physicians successfully obtained central venous access in all subjects in the case series. The use of IM ketamine to facilitate the placement of central venous catheters in children who do not have peripheral venous access appears to be helpful. Emergency physicians may find it useful to be familiar with this use of IM ketamine.

  19. Radiation safety and vascular access: attitudes among cardiologists worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States); Khan, Asrar A. [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States); Xie, Hui [Division of Epidemiology and Biostatistics and Cancer Center, University of Illinois at Chicago, Chicago, Illinois (United States); Shroff, Adhir R. [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States)

    2015-03-15

    Objectives: To determine opinions and perceptions of interventional cardiologists on the topic of radiation and vascular access choice. Background: Transradial approach for cardiac catheterization has been increasing in popularity worldwide. There is evidence that transradial access (TRA) may be associated with increasing radiation doses compared to transfemoral access (TFA). Methods: We distributed a questionnaire to collect opinions of interventional cardiologists around the world. Results: Interventional cardiologists (n = 5332) were contacted by email to complete an on-line survey from September to October 2013. The response rate was 20% (n = 1084). TRA was used in 54% of percutaneous coronary interventions (PCIs). Most TRAs (80%) were performed with right radial access (RRA). Interventionalists perceived that TRA was associated with higher radiation exposure compared to TFA and that RRA was associated with higher radiation exposure that left radial access (LRA). Older interventionalists were more likely to use radiation protection equipment and those who underwent radiation safety training gave more importance to ALARA (as low as reasonably achievable). Nearly half the respondents stated they would perform more TRA if the radiation exposure was similar to TFA. While interventionalists in the United States placed less importance to certain radiation protective equipment, European operators were more concerned with physician and patient radiation. Conclusions: Interventionalists worldwide reported higher perceived radiation doses with TRA compared to TFA and RRA compared to LRA. Efforts should be directed toward encouraging consistent radiation safety training. Major investment and application of novel radiation protection tools and radiation dose reduction strategies should be pursued. - Highlights: • We examined radiation safety and arterial access practices among 1000 cardiologists. • Radial access is perceived as having higher radiation dose compared to

  20. Use of vascular access ports in femoral veins of dogs and cats with cancer.

    Science.gov (United States)

    Cahalane, Alane Kosanovich; Rassnick, Kenneth M; Flanders, James A

    2007-11-01

    To evaluate long-term function of vascular access ports (VAPs) implanted in the femoral vein of dogs and cats undergoing cancer treatment. Prospective clinical study. 3 dogs and 6 cats treated via chemotherapy or radiation. VAPs were surgically implanted in the left femoral vein of 3 dogs and 6 cats over a 1-year period. Injection port location was alternated to either a caudal thoracic or ilial location in each patient. Duration of VAP function, ease of infusion, and ease of aspiration through the VAPs were recorded, and associated complications were assessed at each VAP use. Client satisfaction with VAP placement was evaluated by use of a questionnaire. Primary uses of the VAPs included blood sampling and delivering sedative or chemotherapeutic drugs. Median duration of successful infusion was 147 days (range, 60 to 370 days), and median duration of successful aspiration was 117 days (range, 10 to 271 days). The frequency of signs of VAP-related discomfort was low (7% of patient observations). Clients were satisfied with their decision to use VAPs. Complications included partial (n = 7) or complete (2) VAP occlusion, port migration (1), and presumptive infection (1). Results suggested that VAP implantation into the femoral vein provides an acceptable means of chronic venous access in dogs and cats undergoing cancer treatment.

  1. Virtual reality: emerging role of simulation training in vascular access.

    Science.gov (United States)

    Davidson, Ingemar J A; Lok, Charmaine; Dolmatch, Bart; Gallieni, Maurizio; Nolen, Billy; Pittiruti, Mauro; Ross, John; Slakey, Douglas

    2012-11-01

    Evolving new technologies in vascular access mandate increased attention to patient safety; an often overlooked yet valuable training tool is simulation. For the end-stage renal disease patient, simulation tools are effective for all aspects of creating access for peritoneal dialysis and hemodialysis. Based on aviation principles, known as crew resource management, we place equal emphasis on team training as individual training to improve interactions between team members and systems, cumulating in improved safety. Simulation allows for environmental control and standardized procedures, letting the trainee practice and correct mistakes without harm to patients, compared with traditional patient-based training. Vascular access simulators range from suture devices, to pressurized tunneled conduits for needle cannulation, to computer-based interventional simulators. Simulation training includes simulated case learning, root cause analysis of adverse outcomes, and continual update and refinement of concepts. Implementation of effective human to complex systems interaction in end-stage renal disease patients involves a change in institutional culture. Three concepts discussed in this article are as follows: (1) the need for user-friendly systems and technology to enhance performance, (2) the necessity for members to both train and work together as a team, and (3) the team assigned to use the system must test and practice it to a proficient level before safely using the system on patients. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Complications of an implantable venous access port: Prevention and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok; Song, Myung Gyu [Dept. of Radiology, Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Cha, In Ho [Dept. Radiology, Chungang University Hospital, Chungang University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    Placement of an implantable venous access port (IVAP) is a popular procedure for repeated and intermittent chemotherapy in patients with malignancy. In this article, we present various IVAP related complications. In addition, we review the technical tips to prevent and manage the complications. It is important that the operator should keep the mechanism of the complications in mind, perform a careful procedure for prevention, and manage the complication properly and immediately in case of its development for safety and satisfaction of the patients Complications of an implantable venous access port: Prevention and treatment.

  3. A semi-automated vascular access system for preclinical models

    International Nuclear Information System (INIS)

    Berry-Pusey, B N; David, J; Taschereau, R; Silverman, R W; Williams, D; Ladno, W; Stout, D; Chatziioannou, A; Chang, Y C; Prince, S W; Chu, K; Tsao, T C

    2013-01-01

    Murine models are used extensively in biological and translational research. For many of these studies it is necessary to access the vasculature for the injection of biologically active agents. Among the possible methods for accessing the mouse vasculature, tail vein injections are a routine but critical step for many experimental protocols. To perform successful tail vein injections, a high skill set and experience is required, leaving most scientists ill-suited to perform this task. This can lead to a high variability between injections, which can impact experimental results. To allow more scientists to perform tail vein injections and to decrease the variability between injections, a vascular access system (VAS) that semi-automatically inserts a needle into the tail vein of a mouse was developed. The VAS uses near infrared light, image processing techniques, computer controlled motors, and a pressure feedback system to insert the needle and to validate its proper placement within the vein. The VAS was tested by injecting a commonly used radiolabeled probe (FDG) into the tail veins of five mice. These mice were then imaged using micro-positron emission tomography to measure the percentage of the injected probe remaining in the tail. These studies showed that, on average, the VAS leaves 3.4% of the injected probe in the tail. With these preliminary results, the VAS system demonstrates the potential for improving the accuracy of tail vein injections in mice. (paper)

  4. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  5. SLM Produced Porous Titanium Implant Improvements for Enhanced Vascularization and Osteoblast Seeding

    Science.gov (United States)

    Matena, Julia; Petersen, Svea; Gieseke, Matthias; Kampmann, Andreas; Teske, Michael; Beyerbach, Martin; Murua Escobar, Hugo; Haferkamp, Heinz; Gellrich, Nils-Claudius; Nolte, Ingo

    2015-01-01

    To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM) enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL) coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF), high mobility group box 1 (HMGB1) and chemokine (C-X-C motif) ligand 12 (CXCL12). As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI). Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release. PMID:25849656

  6. SLM Produced Porous Titanium Implant Improvements for Enhanced Vascularization and Osteoblast Seeding

    Directory of Open Access Journals (Sweden)

    Julia Matena

    2015-04-01

    Full Text Available To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF, high mobility group box 1 (HMGB1 and chemokine (C-X-C motif ligand 12 (CXCL12. As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI. Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release.

  7. Acceleration of Medpor implant fibrovascularization with local vascular endothelial growth-factor injections: An experimental study

    Directory of Open Access Journals (Sweden)

    Mert Demirel

    2015-12-01

    Full Text Available Objective: Medpor is a biocompatible, high-density porous polyethylene implant that is used for multiple indications in plastic surgery. The most frequent complications associated with the Medpor implant are infection and implant exposure. The primary cause of these complications is poor fibrovascularization of the Medpor implant and poor nourishment of the overlying skin. The present experimental study aimed to determine whether vascular endothelial growth factor (VEGF could accelerate and increase Medpor implant fibrovascularization in vivo, and thereby improve local nourishment and prevent complications. Materials and Methods: The Medpor implant was inserted under the dorsal skin area in 40 Sprague-Dawley rats. 20 rats receiving local VEGF injections comprised the study group. The control group received saline injections. Fibrovascularization of the Medpor implants was compared. Results: In the rats injected with VEGF, the Medpor implant fibrovascularized faster, and there were more newly formed blood vessels, as compared with those in the control group. Conclusion: These findings have led to our use of VEGF-like agents that the accelerate angiogenesis in the Medpor implant as a means to reduce the incidence of such complications as infection and implant exposure. [Arch Clin Exp Surg 2015; 4(4.000: 196-201

  8. A review of an anaesthetic led vascular access list.

    Science.gov (United States)

    Galloway, S; Sharma, A; Ward, J; Bodenham, A R

    2005-08-01

    The demand for insertion of long-term central venous (Hickman type) catheters is thought to be increasing. Organisation is required to meet this demand in a safe and efficient manner. This report reviews the results from a dedicated, anaesthetic led vascular access list over the initial 61-month period. One thousand procedures were performed. Nine hundred and twenty catheters were inserted under local anaesthesia, with or without intravenous sedation and analgesia. Eighty catheters were removed. All procedures were performed during a dedicated once weekly, morning list. A total of 53% of all procedures were performed on a day-case basis, 43% on in-patients. Only 1.5% of patients required an unexpected overnight stay (usually medically unfit patients). There were 81 (9%) cancellations on the day of procedure due to neutropaenia, pneumonia or urinary tract infections. Ultrasound guidance was used initially selectively in 14%, latterly in 100% of procedures and fluoroscopy in all insertions to confirm or adjust catheter position. This service has been well received by patients and oncology services. In addition it provides an interesting area of practice for anaesthetists and an ideal environment for teaching more advanced aspects of central venous access. It may provide a template of service for other centres.

  9. [Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].

    Science.gov (United States)

    García Cortés, Ma J; Viedma, G; Sánchez Perales, M C; Borrego, F J; Borrego, J; Pérez del Barrio, P; Gil Cunquero, J M; Liébana, A; Pérez Bañasco, V

    2005-01-01

    Autologous access is the best vascular access for dialysis also in older patients and it should be mature when patient needs hemodialysis. It is not always possible. Surgeon availability and demographic characteristics of patients (age, diabetes, vascular disease...) are factors that determine primary vascular access. To analyse outcome and vascular access complications in elderly who start hemodialysis without vascular access. All patients older than 75 years who initiated hemodialysis without vascular access between January 2000 and June 2002 were included, They were divided en two groups depending on primary vascular access. GI: arterio-venous fistulae. GIIl: Tunnelled cuffed catheter. Epidemiological and analytical data, vascular access complications related, as well as patient and first permanent vascular access survival from their inclusion in dialysis up to December 2002 were analysed and compared in both groups. 32 patients were studied. GI: n = 17 (4 men) and GIIl: n =1 5 (8 men), age: 79.9 +/- 3.8 and 81.7 +/- 4 years respectively (ns). There were no differences in sex and comorbidity (diabetes, ischemic heart disease, peripheral vascular disease and hypertension). It took GI 3 months to get a permanent vascular access suitable for using, while it took GIIl 1.3 months (p catheters was higher in GI (3.35 vs 1.87 p central venous thrombosis happen in GI (I: 25 CVT/100 patients-year) vs 30% in GIIl (I = 14.4/100 patients-year) (ns). No significant differences neither in bleeding (66.7% vs 33.3%) nor ischemia (75% vs 25%) were found. Dialysis dose (Kt/V) as well as anaemia degree were similar in both groups. Permanent vascular access survival after 2 years was 45.8% in GI and 24% in GII (ns). Patient survival was similar in GI and GII (72% vs 51% ns). Elderly who start hemodialysis without vascular access took longer to get a suitable permanent vascular access when arterio-venous fistulae is placed than with a tunnelled cuffed hemodialysis catheter. As a

  10. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    Science.gov (United States)

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  11. Sonography and CT findings in perigraft reactions after surgical implantation of vascular prostheses

    International Nuclear Information System (INIS)

    Scherer, G.; Roeren, T.; Paetz, B.; Hupp, T.; Kauffmann, G.W.

    1995-01-01

    Between January 1988 and January 1994, 24 patients with heterologeous vascular bypasses were examined with suspected diagnosis of a perigraft reaction (PGR). All patients were subjected to ultrasound and CT. PGR ist defined as a sterile inflammation along the course of a vascular prosthesis. The typical clinical presentation is a fluctuating tumour with a localised painless swelling. In all cases liquid formations could be confirmed by diagnostic imaging procedures; signs of infection could be excluded. The synopsis of the clinical presentation, the time interval after implantation of the prosthetic material and the signs of sonography and CT can reliably exclude infection of the prosthesis and confirm the diagnosis of a PGR. (orig.) [de

  12. Frequency and Effect of Access-Related Vascular Injury and Subsequent Vascular Intervention After Transcatheter Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Dencker, Ditte; Taudorf, Mikkel; Luk, N H Vincent

    2016-01-01

    patients underwent TAVR and 333 patients (94%) were treated by true percutaneous transfemoral approach. Of this latter group, 83 patients (25%) had an access-related vascular injury that was managed by the use of a covered self-expanding stent (n = 49), balloon angioplasty (n = 33), or by surgical...

  13. Prevalence of blood type A and risk of vascular complications following transcatheter aortic valve implantation.

    Science.gov (United States)

    Rofe, M-T; Shacham, Y; Steinvi, A; Barak, L; Hareuveni, M; Banai, S; Keren, G; Finkelstein, A; Shmilovich, H

    2016-05-01

    To assess the prevalence of blood type A among patients referred for transcatheter aortic valve implantation (TAVI) and whether it is related to vascular complications. Vascular complications following TAVI are associated with adverse outcomes. Various blood types, particularly type A, have been shown to be more prevalent in cardiovascular diseases and to be related to prognosis. The prevalence of various blood types in a cohort of 491 consecutive patients who underwent TAVI was compared with a control group of 6500 consecutive hospitalised patients. The prevalence and predictors of vascular complications and bleeding events were evaluated in the blood type A group and were compared with non-type A patients. The mean age of TAVI patients was 83 ± 6 years, and 40 % were males. Patients were divided into two groups: blood type A (n = 220) and non-type A (n = 271). Type A was significantly more prevalent in the TAVI group than in the control group (45 vs. 38 %, p = 0.023). Compared with the non-type A group, patients with blood type A had more major and fatal bleeding (14.5 vs. 8.1 %, p = 0.027) and more vascular complications (any vascular complication: 24.5 vs. 15.9 % p = 0.016; major vascular complications: 12.3 vs. 7 % p = 0.047). In a multivariable analysis, blood type A emerged as a significant and independent predictor for vascular complications and bleeding events. Blood type A is significantly more prevalent in TAVI patients than in the general population and is related to higher rates of vascular and bleeding complications.

  14. Validity of administrative database code algorithms to identify vascular access placement, surgical revisions, and secondary patency.

    Science.gov (United States)

    Al-Jaishi, Ahmed A; Moist, Louise M; Oliver, Matthew J; Nash, Danielle M; Fleet, Jamie L; Garg, Amit X; Lok, Charmaine E

    2018-03-01

    We assessed the validity of physician billing codes and hospital admission using International Classification of Diseases 10th revision codes to identify vascular access placement, secondary patency, and surgical revisions in administrative data. We included adults (≥18 years) with a vascular access placed between 1 April 2004 and 31 March 2013 at the University Health Network, Toronto. Our reference standard was a prospective vascular access database (VASPRO) that contains information on vascular access type and dates of placement, dates for failure, and any revisions. We used VASPRO to assess the validity of different administrative coding algorithms by calculating the sensitivity, specificity, and positive predictive values of vascular access events. The sensitivity (95% confidence interval) of the best performing algorithm to identify arteriovenous access placement was 86% (83%, 89%) and specificity was 92% (89%, 93%). The corresponding numbers to identify catheter insertion were 84% (82%, 86%) and 84% (80%, 87%), respectively. The sensitivity of the best performing coding algorithm to identify arteriovenous access surgical revisions was 81% (67%, 90%) and specificity was 89% (87%, 90%). The algorithm capturing arteriovenous access placement and catheter insertion had a positive predictive value greater than 90% and arteriovenous access surgical revisions had a positive predictive value of 20%. The duration of arteriovenous access secondary patency was on average 578 (553, 603) days in VASPRO and 555 (530, 580) days in administrative databases. Administrative data algorithms have fair to good operating characteristics to identify vascular access placement and arteriovenous access secondary patency. Low positive predictive values for surgical revisions algorithm suggest that administrative data should only be used to rule out the occurrence of an event.

  15. An implantable vascularized protein gel construct that supports human fetal hepatoblast survival and infection by hepatitis C virus in mice.

    Directory of Open Access Journals (Sweden)

    Martha J Harding

    2010-04-01

    Full Text Available Widely accessible small animal models suitable for the study of hepatitis C virus (HCV in vivo are lacking, primarily because rodent hepatocytes cannot be productively infected and because human hepatocytes are not easily engrafted in immunodeficient mice.We report here on a novel approach for human hepatocyte engraftment that involves subcutaneous implantation of primary human fetal hepatoblasts (HFH within a vascularized rat collagen type I/human fibronectin (rCI/hFN gel containing Bcl-2-transduced human umbilical vein endothelial cells (Bcl-2-HUVEC in severe combined immunodeficient X beige (SCID/bg mice. Maturing hepatic epithelial cells in HFH/Bcl-2-HUVEC co-implants displayed endocytotic activity at the basolateral surface, canalicular microvilli and apical tight junctions between adjacent cells assessed by transmission electron microscopy. Some primary HFH, but not Huh-7.5 hepatoma cells, appeared to differentiate towards a cholangiocyte lineage within the gels, based on histological appearance and cytokeratin 7 (CK7 mRNA and protein expression. Levels of human albumin and hepatic nuclear factor 4alpha (HNF4alpha mRNA expression in gel implants and plasma human albumin levels in mice engrafted with HFH and Bcl-2-HUVEC were somewhat enhanced by including murine liver-like basement membrane (mLBM components and/or hepatocyte growth factor (HGF-HUVEC within the gel matrix. Following ex vivo viral adsorption, both HFH/Bcl-2-HUVEC and Huh-7.5/Bcl-2-HUVEC co-implants sustained HCV Jc1 infection for at least 2 weeks in vivo, based on qRT-PCR and immunoelectron microscopic (IEM analyses of gel tissue.The system described here thus provides the basis for a simple and robust small animal model of HFH engraftment that is applicable to the study of HCV infections in vivo.

  16. Straight configuration saphenous vein transposition to popliteal artery for vascular access.

    Science.gov (United States)

    Caco, Gentian; Golemi, Dhurata; Likaj, Eriola

    2017-03-21

    The saphenous vein is commonly used as a vascular graft in peripheral artery surgery but rarely used for vascular access. The literature on straight configuration saphenous vein transposition to the popliteal artery is scarce. Here we present two cases of straight configuration saphenous vein transposition to the popliteal artery for vascular access, the surgical technique and respective follow-up. Two young men, aged 29 and 36 years, were chosen for lower-limb vascular access for hemodialysis. The first patient was paraplegic since birth. He used his arms to move so upper extremity vascular access was avoided. The second patient presented with an infected upper extremity arteriovenous graft (AVG) and after multiple closed AVFs he had no more available arm veins. Both patients received autologous lower extremity straight configuration saphenous vein transpositions to the popliteal artery under spinal anesthesia in May and October 2012, respectively. Cannulation of the fistula was allowed after one month. There were no early complications. Slight swelling on the leg appeared in one of the patients. Both fistulas were still functional after 36 and 32 months, respectively. The straight configuration saphenous vein transposition to popliteal artery is simple to perform, offers a long and straight segment for cannulation and may be a suitable autologous vascular access in selected patients.

  17. Vascular access in lipoprotein apheresis: a retrospective analysis from the UK's largest lipoprotein apheresis centre.

    Science.gov (United States)

    Doherty, Daniel J; Pottle, Alison; Malietzis, George; Hakim, Nadey; Barbir, Mahmoud; Crane, Jeremy S

    2018-01-01

    Lipoprotein apheresis (LA) has proven to be an effective, safe and life-saving therapy. Vascular access is needed to facilitate this treatment but has recognised complications. Despite consistency in treatment indication and duration there are no guidelines in place. The aim of this study is to characterise vascular access practice at the UK's largest LA centre and forward suggestions for future approaches. A retrospective analysis of vascular access strategies was undertaken in all patients who received LA treatment in the low-density lipoprotein (LDL) Apheresis Unit at Harefield Hospital (Middlesex, UK) from November 2000 to March 2016. Fifty-three former and current patients underwent 4260 LA treatments. Peripheral vein cannulation represented 79% of initial vascular access strategies with arteriovenous (AV) fistula use accounting for 15%. Last used method of vascular access was peripheral vein cannulation in 57% versus AV fistula in 32%. Total AV fistula failure rate was 37%. Peripheral vein cannulation remains the most common method to facilitate LA. Practice trends indicate a move towards AV fistula creation; the favoured approach receiving support from the expert body in this area. AV fistula failure rate is high and of great concern, therefore we suggest the implementation of upper limb ultrasound vascular mapping in all patients who meet treatment eligibility criteria. We encourage close ties between apheresis units and specialist surgical centres to facilitate patient counselling and monitoring. Further prospective data regarding fistula failure is needed in this expanding treatment field.

  18. [Pulmonary reperfusion syndrome after pulmonary stent implants in a patient with vascular tortuosity syndrome].

    Science.gov (United States)

    Berenguer Potenciano, M; Piris Borregas, S; Mendoza Soto, A; Velasco Bayon, J M; Caro Barri, A

    2015-01-01

    Vascular tortuosity syndrome is a rare genetic disorder that causes tortuosity and stenosis of the pulmonary, systemic and / or coronary circulations. As a result of treatment of pulmonary stenosis, symptoms of pulmonary edema, known as lung reperfusion syndrome, may occur. The case is presented of an adolescent patient with vascular tortuosity syndrome who presented with a pulmonary reperfusion syndrome after multiple stent implants in the left pulmonary artery. After the procedure, the patient immediately developed an acute pulmonary edema with severe clinical deterioration, which required assistance with extracorporeal membrane oxygenation for recovery. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  19. Prefabrication of a vascularized nerve graft by vessel implantation: preliminary report of an experimental model.

    Science.gov (United States)

    Cavadas, P C; Vera-Sempere, F J

    1994-01-01

    Regeneration through vascularized nerve grafts (VNG) seems to be better than nonvascularized nerve grafts (NVNG), especially in hostile beds. We report on an experimental technique of prefabrication of VNG by direct vessel implantation. An arteriovenous fistula was created in the groin region with autologous vein grafts in the Wistar rat model, and implanted into the sciatic nerve. Five weeks later the sciatic VNG was elevated on the prefabricated pedicle. The flap was free-transferred orthotopically over a silicone sheet to impede plasmatic imbibition. Flap viability at 3 days was complete. India ink injection of the AV fistula resulted in capillary ink filling within the nerve and surrounding tissues. Histologic sections of the flap were examined, revealing its neovascularity. In an ongoing study, the regeneration through this prefabricated VNG is being compared to native VNG.

  20. [Experimental study on vascular bundle implantation combined with cellular transplantation in treating rabbit femoral head necrosis].

    Science.gov (United States)

    Chen, Shuang-Tao; Zhang, Wei-Ping; Liu, Chang-An; Wang, Jun-Jiang; Song, Heng-Yi; Chai, Zhi-wen

    2013-03-01

    To discuss the feasibility of vascular bundle implantation combined with allogeneic bone marrow stromal cells (BMSCs) transplantation in treating rabbit femoral head osteonecrosis and bone defect, in order to explore a new method for the treatment of femoral head necrosis. Thirty-six New Zealand rabbits were randomly divided into three groups,with 12 rabbits in each group. Bilateral femoral heads of the rabbits were studied in the experiment. The models were made by liquid nitrogen frozen, and the femoral heads were drilled to cause bone defect. Group A was the control group,group B was stem cells transplantaion group of allograft marrow stromal,and group C was stem cells transplantation group of allograft marrow stromal combined with vascular bundle implantation. Three rabbits of each group were sacrificed respectively at 2, 4, 8, 12 weeks after operation. All specimens of the femoral heads were sliced for HE staining. Furthermore ,vascular density and the percentage of new bone trabecula of femoral head coronary section in defect area were measured and analyzed statistically. In group C,new bone trabecula and original micrangium formed at the 2nd week after operation; new bone trabecula was lamellar and interlaced with abundant micrangium at the 8th week;at the 12th week,the broadened,coarsened bone trabecula lined up regularly,and the mature bone trabecula and new marrow were visible. At the 2nd week after operation,there was no statistical significance in the percentage of new bone trabecula of femoral head coronary section in defect area between group B and C. While at 4, 8, 12 week after operation, vascular density and the percentage of new bone trabecula of femoral head coronary section in defect area of group C was higher than that of group B. Allogeneic bone marrow stromal cells cultured in vivo can form new bone trabecula, and can be applied to allotransplant. Vascular bundle implanted into the bone defect area of femoral head necrosis could improve blood

  1. Survey of home hemodialysis patients and nursing staff regarding vascular access use and care

    OpenAIRE

    Spry, Leslie A; Burkart, John M; Holcroft, Christina; Mortier, Leigh; Glickman, Joel D

    2014-01-01

    Vascular access infections are of concern to hemodialysis patients and nurses. Best demonstrated practices (BDPs) have not been developed for home hemodialysis (HHD) access use, but there have been generally accepted practices (GAPs) endorsed by dialysis professionals. We developed a survey to gather information about training provided and actual practices of HHD patients using the NxStage System One HHD machine. We used GAP to assess training used by nurses to teach HHD access care and then ...

  2. Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

    International Nuclear Information System (INIS)

    Breault, Stéphane; Glauser, Frédéric; Babaker, Malik; Doenz, Francesco; Qanadli, Salah Dine

    2015-01-01

    PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement

  3. Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Breault, Stéphane, E-mail: stephane.breault@chuv.ch [Lausanne University Hospital, Diagnostic and Interventional Radiology Department (Switzerland); Glauser, Frédéric, E-mail: frederic.glauser@chuv.ch [Lausanne University Hospital, Angiology and Diagnostic and Interventional Radiology Departments (Switzerland); Babaker, Malik, E-mail: malik.babaker@chuv.ch; Doenz, Francesco, E-mail: francesco.doenz@chuv.ch; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [Lausanne University Hospital, Diagnostic and Interventional Radiology Department (Switzerland)

    2015-06-15

    PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

  4. Assessment of vascularization within hydroxyapatite ocular implant by bone scintigraphy: compartive analysis of planar and SPECT imaging

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee; Park, Soon Ah

    1999-01-01

    Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Seventeen patients (M:F=12:5, mean age: 50.4±17.5 years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: 197±81 days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake. The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization (1.96±9.87 vs 1.17±0.08 , p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization (8.44±5.45 vs 2.20±0.87, p<0.05). In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy

  5. Vascular access for hemodialysis. Patency rates and results of revision.

    Science.gov (United States)

    Palder, S B; Kirkman, R L; Whittemore, A D; Hakim, R M; Lazarus, J M; Tilney, N L

    1985-08-01

    Over a 4-year interval, 324 arteriovenous conduits were created in 256 patients with end-stage renal disease as access for chronic hemodialysis. These included 154 Cimino fistulae, 163 polytetrafluoroethylene (PTFE) grafts, and seven miscellaneous grafts. Satisfactory patency rates were demonstrated for as long as 4 years for both Cimino fistulae and PTFE grafts by life-table analysis. Failures of Cimino fistulae usually occurred early in the postoperative period, secondary to attempts to use inadequate veins. Thrombosis caused the majority of PTFE graft failures and was generally the result of venous stenosis. Correction of such venous stenosis is mandatory to restore graft patency and can result in prolonged graft survival.

  6. A technique for the management of screw access opening in cement-retained implant restorations

    Directory of Open Access Journals (Sweden)

    Hamid Kermanshah

    2014-01-01

    Full Text Available Introduction: Abutment screw loosening has been considered as a common complication of implant-supported dental prostheses. This problem is more important in cement-retained implant restorations due to their invisible position of the screw access opening. Case Report: This report describes a modified retrievability method for cement-retained implant restorations in the event of abutment screw loosening. The screw access opening was marked with ceramic stain and its porcelain surface was treated using hydrofluoric acid (HF, silane, and adhesive to bond to composite resin. Discussion: The present modified technique facilitates screw access opening and improves the bond between the porcelain and composite resin.

  7. The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker Implantation.

    Science.gov (United States)

    Esmaiel, Abdullah; Hassan, Jeremy; Blenkhorn, Fay; Mardigyan, Vartan

    2016-05-01

    The Agency for Healthcare Research and Quality in the United States recommends the use of ultrasound (US) for central venous access to improve patient outcomes. However, in a recent publication, US is still underutilized for axillary vein access during pacemaker implantation. We sought to describe a technique for US-guided axillary vein access during pacemaker implantation and to report complication rates and success rate. Retrospective data collection included success rate and complications on all pacemaker implants by one operator since implementing the systematic use of US at our institution, from November 2012 to January 2015. For the last 59 cases, data were collected prospectively to include time of venous access and number of attempts. A total of 403 consecutive patients were included in the analysis. Two leads were implanted in 255 cases and one lead was implanted in 148 cases. The rate of successful US-guided access was 99.25%. There were no access-related complications. The average number of venipuncture attempts was 1.18 per patient. The average time to obtain venous access was 2.24 minutes including the time to apply the sterile US sleeve. The described technique has the potential to improve the success rate of axillary vein access and minimize complications during pacemaker implantation. ©2016 Wiley Periodicals, Inc.

  8. Use of vascular access for haemodialysis in Europe: a report from the ERA-EDTA Registry

    NARCIS (Netherlands)

    Noordzij, Marlies; Jager, Kitty J.; van der Veer, Sabine N.; Kramar, Reinhard; Collart, Frederic; Heaf, James G.; Stojceva-Taneva, Olivera; Leivestad, Torbjørn; Buturovic-Ponikvar, Jadranka; Benítez Sánchez, Manuel; Moreso, Fransesc; Prütz, Karl G.; Severn, Alison; Wanner, Christoph; Vanholder, Raymond; Ravani, Pietro

    2014-01-01

    Although arteriovenous fistulas (AVFs) are actively promoted, their use at the start of haemodialysis (HD) seems to be decreasing worldwide. In this paper, we describe recent trends in incidence and prevalence of vascular access types in Europe from 2005 to 2009 and their relationship with patient

  9. 78 FR 38867 - Gastroenterology-Urology Devices; Reclassification of Implanted Blood Access Devices

    Science.gov (United States)

    2013-06-28

    ... artificial kidney system for the treatment of patients with renal failure or toxemic conditions and provides.... Additionally, some patients may have inadequate vascular anatomy to establish a more permanent vascular access... Kidney Diseases, vol. 30, pp. 213-218, 1997. 11. Schnabel, K.J., M.E. Simons, G.F. Zevallos, et al...

  10. Improving vascular access outcomes: attributes of arteriovenous fistula cannulation success

    Science.gov (United States)

    Harwood, Lori E.; Wilson, Barbara M.; Oudshoorn, Abe

    2016-01-01

    Background Arteriovenous fistulas (AVFs) are the preferred access for hemodialysis (HD) yet they are underutilized. Cannulation of the fistula is a procedure requiring significant skill development and refinement and if not done well can have negative consequences for patients. The nurses' approach, attitude and skill with cannulation impacts greatly on the patient experience. Complications from miscannulation or an inability to needle fistulas can result in the increased use of central venous catheters. Some nurses remain in a state of a ‘perpetual novice’ resulting in a viscous cycle of negative patient consequences (bruising, pain), further influencing patients' decisions not to pursue a fistula or abandon cannulation. Method This qualitative study used organizational development theory (appreciative inquiry) and research method to determine what attributes/activities contribute to successful cannulation. This can be applied to interventions to promote change and skill development in staff members who have not advanced their proficiency. Eighteen HD nurses who self-identified with performing successful cannulation participated in audio-recorded interviews. The recordings were transcribed verbatim. The data were analyzed using content analysis. Results Four common themes, including patient-centered care, teamwork, opportunity and skill and nurse self-awareness, represented successful fistula cannulation. Successful cannulation is more than a learned technique to correctly insert a needle, but rather represents contextual influences and interplay between the practice environment and personal attributes. Conclusions Practice changes based on these results may improve cannulation, decrease complications and result in better outcomes for patients. Efforts to nurture positive patient experiences around cannulation may influence patient decision-making regarding fistula use. PMID:26985384

  11. Incidence of vascular complications during lateral lumbar interbody fusion: an examination of the mini-open access technique.

    Science.gov (United States)

    Kueper, Janina; Fantini, Gary A; Walker, Brendon R; Aichmair, Alexander; Hughes, Alexander P

    2015-04-01

    This article examines the incidence and management of vascular injury during Lateral Lumbar Interbody Fusion (LLIF). The details of the mini-open access technique are presented. A total of 900 patients who underwent a LLIF at an average 1.94 levels (range: 1-5 levels) by one of six fellowship trained surgeons on 1,754 levels from 2006 to 2013 were identified. The incidence of intraoperative vascular injury was retrospectively determined from the Operative Records. The management of vascular injury was evaluated. The mini-open access adapted by our institution for LLIF is described. The incidence of major vascular complication in our series was 1/900. The incidence of minor vascular injury was 4/900. The overall incidence of vascular injury was calculated to be 0.056 % per case and 0.029 % per level. All minor vascular injuries were identified to be segmental vessel lacerations, which were readily ligated under direct visualization without further extension of the incision with no clinical sequelae. The laceration of the abdominal aorta, the major vascular complication of this series, was emergently repaired through an exploratory laparotomy. None of the patients suffered long-term sequelae from their intraoperative vascular injuries. The mini-open lateral access technique for LLIF provides for minimal risk of vascular injury to the lumbar spine. In the rare event of minor vascular injury, the mini-open access approach allows for immediate visualization, confirmation and repair of the vessel with no long-term sequelae.

  12. The versatility of intraosseous vascular access in perioperative medicine: a case series.

    Science.gov (United States)

    Anson, Jonathan A; Sinz, Elizabeth H; Swick, John T

    2015-02-01

    Intraosseous vascular access is a time-tested procedure that is reemerging in popularity. This is primarily a result of the emphasis on intraosseous access in the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Advanced Cardiac Life Support. Modern intraosseous insertion devices are easy to learn and use, suggesting the possibility of use beyond the resuscitation setting. We present a case series of recent intraosseous insertions for a variety of indications by anesthesiologists at our institution to demonstrate the potential utility of this alternative access technique. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Covering the screw-access holes of implant restorations in the esthetic zone: a clinical report.

    Directory of Open Access Journals (Sweden)

    Abolfazl Saboury

    2014-12-01

    Full Text Available Screw-retained implant restorations have an advantage of predictable retention as well as retrievability, and obviate the risk of excessive sub-gingival cement commonly associated with cement retained implant restorations. Screw-retained restorations generally have screw access holes, which can compromise esthetics and weaken the porcelain around the holes. The purpose of this study is to describe the use of a separate overcasting crown design to cover the screw access hole of implant screw-retained prosthesis for improved esthetics.

  14. CO2 angiography of vascular access in hemodialysis: a preliminary report

    International Nuclear Information System (INIS)

    Li Huimin; Xiao Xiangsheng; Yan Bing; Dong Sheng; Li Wentao; Dong Yonghua; Ye Chaoyang; Rong Shu

    2005-01-01

    Objective: To explore the technique and value of CO 2 angiography in surveillance of vascular access in hemodialysis. Methods: CO 2 angiography was undertaken in 10 chronic renal failure (CRF) patients with native arteriovenous fistulas for hemodialysis. The injection sites were the vein dorsale manus (n=7) and the fistula (n=3). The whole draining veins were obtained using a Toshiba DSA unit, when 40-60 ml gas were injected by hands every time. The compression on elbow and image stacking technique were used. Results: All patients had a safe examination, and the vessels on the CO 2 venogram were tubular or bubble-flow. A significant draining vein was revealed in 4 cases (3 of them injection from fistula). The elbow compression had the effect on venogram in 2 cases. All of the draining veins above the elbow were clearly visualized, and the stacking technique imp roved the display of veins. Conclusion: Internal fistula CO 2 angiography is safe, cheap, and efficacy for dialysis access surveillance. The draining veins of vascular access in CRF patients have their own characteristics, and can be best revealed by direct internal fistula CO 2 venography. CO 2 angiogram of the vascular access can be improved with various kinds of skills. (authors)

  15. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  16. [Reason for "choosing" peritoneal dialysis: exhaustion of vascular access for hemodialysis?].

    Science.gov (United States)

    Rocha, Paulo Novis; Sallenave, Mila; Casqueiro, Verena; Campelo Neto, Bolivar; Presídio, Sérgio

    2010-03-01

    Little is known about the prognosis of patients beginning peritoneal dialysis (PD) as their last alternative. To describe the clinical-demographic profile of patients switching from hemodialysis (HD) to PD, due to exhaustion of the HD vascular access, and the occurrence of peritonitis among them. Review of the medical records of all patients in the PD program of the Hospital Roberto Santos in the city of Salvador, state of Bahia, Brazil. The study comprised 22 patients (median age, 47.9 years), 54.5% of whom were men, 84.2%, black or mulattoes, and 68.2% originated from the inner Bahia state. Peritoneal dialysis was the initial modality of renal substitutive therapy (RST) in only four of those patients. The remaining 18 patients began RST through HD, mainly on an emergency basis and by using double-lumen catheter (DLC). In a median of 7.7 months on HD, most patients (64.7%) used four or more DLCs. In only 7/18 (39%) patients, the switch from HD to PD was based on the patient';s choice; in most cases, 11/18 (61%), the reason for switching to PD was exhaustion of HD vascular access. Peritonitis was more frequent in patients switching to PD due to exhaustion of HD vascular access than in the rest of the group. Initiating RST on an emergency basis through HD and using DLC may lead to a fast exhaustion of vascular access, leaving PD as the only viable option. This inadequate mode of patient "selection" for PD is associated with a higher risk for peritonitis.

  17. Intraosseous vascular access defect: fracture mimic in the skeletal survey for child abuse

    International Nuclear Information System (INIS)

    Harty, Mary P.; Kao, Simon C.

    2002-01-01

    Two infants were transferred to the emergency department for injuries suggestive of child abuse. Skeletal surveys showed cortical bone defects in the proximal tibiae that were initially interpreted as healing fractures. Further investigation, however, revealed that intraosseous (IO) vascular access needles had been placed at these sites in both infants. In the appropriate clinical setting, a cortical lesion in the proximal tibia corresponding to the site of IO needle insertion should not be mistaken for a radiographic sign of child abuse. (orig.)

  18. Intraosseous vascular access defect: fracture mimic in the skeletal survey for child abuse

    Energy Technology Data Exchange (ETDEWEB)

    Harty, Mary P.; Kao, Simon C. [Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA (United States)

    2002-03-01

    Two infants were transferred to the emergency department for injuries suggestive of child abuse. Skeletal surveys showed cortical bone defects in the proximal tibiae that were initially interpreted as healing fractures. Further investigation, however, revealed that intraosseous (IO) vascular access needles had been placed at these sites in both infants. In the appropriate clinical setting, a cortical lesion in the proximal tibia corresponding to the site of IO needle insertion should not be mistaken for a radiographic sign of child abuse. (orig.)

  19. Prospects for Vascular Access Education in Developing Countries: Current Situation in Cambodia.

    Science.gov (United States)

    Naganuma, Toshihide; Takemoto, Yoshiaki

    2017-01-01

    We report our activities training doctors on vascular access procedures at International University (IU) Hospital in Cambodia through a program facilitated by Ubiquitous Blood Purification International, a nonprofit organization that provides medical support to developing countries in the field of dialysis medicine. Six doctors from Japan have been involved in the education of medical personnel at IU, and we have collectively visited Cambodia about 15 times from 2010 to 2016. In these visits, we have performed many operations, including 42 for arteriovenous fistula, 1 arteriovenous graft, and 1 percutaneous transluminal angioplasty. Stable development and management of vascular access is increasingly required in Cambodia due to increased use of dialysis therapy, and training of doctors in this technique is urgently required. However, we have encountered several difficulties that need to be addressed, including (1) the situation of personnel receiving this training, (2) problems with facilities, including medical equipment and drugs, (3) financial limitations, and (4) problems with management of vascular access. © 2017 S. Karger AG, Basel.

  20. Efficacy of SMART Stent Placement for Salvage Angioplasty in Hemodialysis Patients with Recurrent Vascular Access Stenosis

    Directory of Open Access Journals (Sweden)

    Shingo Hatakeyama

    2011-01-01

    Full Text Available Vascular access stenosis is a major complication in hemodialysis patients. We prospectively observed 50 patients in whom 50 nitinol shape-memory alloy-recoverable technology (SMART stents were used as salvage therapy for recurrent peripheral venous stenosis. Twenty-five stents each were deployed in native arteriovenous fistula (AVF and synthetic arteriovenous polyurethane graft (AVG cases. Vascular access patency rates were calculated by Kaplan-Meier analysis. The primary patency rates in AVF versus AVG at 3, 6, and 12 months were 80.3% versus 75.6%, 64.9% versus 28.3%, and 32.3% versus 18.9%, respectively. The secondary patency rates in AVF versus AVG at 3, 6, and 12 months were 88.5% versus 75.5%, 82.6% versus 61.8%, and 74.4% versus 61.8%, respectively. Although there were no statistically significant difference in patency between AVF and AVG, AVG showed poor tendency in primary and secondary patency. The usefulness of SMART stents was limited in a short period of time in hemodialysis patients with recurrent vascular access stenosis.

  1. Towards retrievable vascularized bioartificial pancreas: induction and long-lasting stability of polymeric mesh implant vascularized with the help of acidic and basic fibroblast growth factors and hydrogel coating.

    Science.gov (United States)

    Prokop, A; Kozlov, E; Nun Non, S; Dikov, M M; Sephel, G C; Whitsitt, J S; Davidson, J M

    2001-01-01

    We seek to improve existing methodologies for allogenic grafting of pancreatic islets. The lack of success of encapsulated transplanted islets inside the peritoneal cavity is presently attributed to poor vascularization of the implant. A thick, fibrotic capsule often surrounds the graft, limiting survival. We have tested the hypothesis that neovascularization of the graft material can be induced by the addition of proper angiogenic factors embedded within a polymeric coat. Biocompatible and nonresorbable meshes coated with hydrophilic polymers were implanted in rats and harvested after 1-, 6-, and 12-week intervals. The implant response was assessed by histological observations on the degree of vascularity, fibrosis, and inflammation. Macrostructural geometry of meshes was conducive to tissue ingrowth into the interstitial space between the mesh filaments. Hydrogel coating with incorporated acidic or basic FGF in an electrostatic complex with polyelectrolytes and/or with heparin provided a sustained slow release of the angiogenic growth factor. Anti-factor VIII and anti-collagen type IV antibodies and a GSL I-B4 lectin were used to measure the extent of vascularization. Vigorous and persistent vascularization radiated several hundred microns from the implant. The level of vascularization should provide a sufficient diffusion of nutrients and oxygen to implanted islets. Based on our observations, stable vascularization may require a sustained angiogenic signal to allow for the development of a permanent implant structure.

  2. The Relationship between Vascular Endothelial Growth Factor 1154G/A Polymorphism and Recurrent Implantation Failure

    Science.gov (United States)

    Vagnini, Laura D.; Nascimento, Adriana M.; Canas, Maria do Carmo T.; Renzi, Adriana; Oliveira-Pelegrin, Gabriela R.; Petersen, Claudia G.; Mauri, Ana L.; Oliveira, João Batista A.; Baruffi, Ricardo L.R.; Cavagna, Mario; Franco, José G.

    2015-01-01

    Objective The aim of this study was to investigate the relationship between herpesvirus-associated ubiquitin-specific protease (HAUSP A/G, rs1529916), tumor protein p53 (TP53 Arg/Pro, rs1042522), leukemia inhibitory factor (LIF G/T, rs929271), glycoprotein 130 (gp130 A/T, rs1900173) and vascular endothelial growth factor (VEGF G/A, rs1570360) polymorphisms and recurrent implantation failure (RIF) in Brazilian women. Subjects and Methods A total of 120 women with RIF (i.e. those with ≥5 cleaved embryos transferred and a minimum of 2 failed in vitro fertilization/intracytoplasmic sperm injection attempts) were included. The control group involved 89 women who had experienced at least 1 live birth (without any infertility treatment). DNA was extracted from the peripheral blood of all participants, and the abovementioned single-nucleotide polymorphisms (SNPs) were genotyped by real-time polymerase chain reaction. The data were evaluated using Fisher's test. Results A significant difference between the RIF and control groups was found in the VEGF gene where the GG genotype showed a 2.1-fold increased chance of not being included in the RIF group, while the presence of an A allele increased this risk 1.6-fold. No significant differences were found for the other polymorphisms. Conclusion This study showed an association between the VEGF -1154G/A polymorphism and RIF in Brazilian women. PMID:26305668

  3. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    Science.gov (United States)

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  4. Intraosseous vascular access through the anterior mandible--a cadaver model pilot study.

    Directory of Open Access Journals (Sweden)

    Christin Goldschalt

    Full Text Available BACKGROUND: Several insertion sites have been described for intraosseous puncture in cases of emergencies when a conventional vascular access cannot be established. This pilot study has been designed to evaluate the feasibility of the mandibular bone for the use of an intraosseous vascular access in a cadaver model. METHODOLOGY/PRINCIPAL FINDINGS: 17 dentistry and 16 medical students participating in a voluntary course received a short introduction into the method and subsequently used the battery powered EZ-IO system with a 15 mm cannula for a puncture of the anterior mandible in 33 cadavers. The time needed to perform each procedure was evaluated. India ink was injected into the accesses and during the anatomy course cadavers were dissected to retrace the success or failure of the puncture. Dental students needed 25.5±18.9(mean±standard deviations and medical students 33±20.4 s for the procedure (p = 0.18. Floor of mouth extravasation occurred in both groups in 3 cases. Success rates were 82 and 75% (p = 0.93. CONCLUSIONS/SIGNIFICANCE: Despite floor of mouth extravasation of injected fluid into a mandibular intraosseous access might severely complicate this procedure, the anterior mandible may be helpful as an alternative to other intraosseous and intravenous insertion sites when these are not available in medical emergencies.

  5. Intraosseous vascular access in disasters and mass casualty events: A review of the literature.

    Science.gov (United States)

    Burgert, James M

    2016-01-01

    The intraosseous (IO) route of vascular access has been increasingly used to administer resuscitative fluids and drugs to patients in whom reliable intravenous (IV) access could not be rapidly or easily obtained. It is unknown that to what extent the IO route has been used to gain vascular access during disasters and mass casualty events. The purpose of this review was to examine the existing literature to answer the research question, "What is the utility of the IO route compared to other routes for establishing vascular access in patients resulting from disasters and mass casualty events?" Keyword-based online database search of PubMed, CINAHL, and the Cochrane Database of Systematic Reviews. University-based academic research cell. Included evidence were randomized and nonrandomized trials, systematic reviews with and without meta-analysis, case series, and case reports. Excluded evidence included narrative reviews and expert opinion. Not applicable. Of 297 evidence sources located, 22 met inclusion criteria. Located evidence was organized into four categories including chemical agent poisoning, IO placement, while wearing chemical protective clothing (PPE), military trauma, and infectious disease outbreak. Evidence indicates that the IO route of infusion is pharmacokinetically equal to the IV route and superior to the intramuscular (IM) and endotracheal routes for the administration of antidotal drugs in animal models of chemical agent poisoning while wearing full chemical PPE. The IO route is superior to the IM route for antidote administration during hypovolemic shock. Civilian casualties of explosive attacks and mass shootings would likely benefit from expanded use of the IO route and military resuscitation strategies. The IO route is useful for fluid resuscitation in the management of diarrheal and hemorrhagic infectious disease outbreaks.

  6. Exact measurement of vascular lumina in digital subtraction arteriography (DSA) during stent implantations and percutaneous transluminal angioplasty (PTA)

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, T [Dept. of Radiology, Univ. of Munich (Germany); Kueffer, G [Dept. of Radiology, Univ. of Munich (Germany); Hahn, D [Dept. of Radiology, Univ. of Munich (Germany)

    1992-06-01

    There are inherent difficulties in using high-resolution DSA in interventional radiology for measuring vascular luminal diameter since enlargement ratios are not constant. We present a system that permits accurate determination of vascular lumen diameters by means of a special angiographic catheter with predefined marking points. The accuracy of this measuring method was explored in tests using phantoms. In vivo practicability of the method was proved in PTA and stent implantations in 39 patients. This method with a maximum error of measurement of 5% appears to provide adequate safety in the choice of suitable dilating balloons and stents in interventional vascular procedures. In follow-up, it permits the accurate measurement of neo-intimal thickness. (orig.)

  7. [Recurrent vascular access trombosis associated with the prothrombin mutation G20210A in a adult patient in haemodialysis].

    Science.gov (United States)

    Quintana, L F; Coll, E; Monteagudo, I; Collado, S; López-Pedret, J; Cases, A

    2005-01-01

    Vascular access-related complications are a frequent cause of morbidity in haemodialysis patients and generate high costs. We present the case of an adult patient with end-stage renal disease and recurrent vascular access thrombosis associated with the prothrombin mutation G20210A and renal graft intolerance. The clinical expression of this heterozygous gene mutation may have been favoured by inflammatory state, frequent in dialysis patients. In this patient, the inflammatory response associated with the renal graft intolerance would have favored the development of recurrent vascular access thrombosis in a adult heterozygous for prothrombin mutation G20210A. In the case of early dysfunction of haemodialysis vascular access and after ruling out technical problems, it is convenient to carry out a screening for thrombophilia.

  8. Time course of fibronectin in the peri-implant tissue and neointima formation after functional implantation of polyester-based vascular prostheses with different porosity in pigs

    Energy Technology Data Exchange (ETDEWEB)

    Patrzyk, Maciej; Hoene, Andreas [Department of Surgery, Ernst Moritz Arndt University Greifswald, Friedrich-Loeffler-Str. 23, D-17489 Greifswald (Germany); Jarchow, Raymond [Computation Centre, Ernst Moritz Arndt University Greifswald, Felix-Hausdorff-Str. 12, D-17489 Greifswald (Germany); Wilhelm, Lutz [Department of Surgery, Hospital Demmin, Loitzer Str. 1, D-17109 Demmin (Germany); Walschus, Uwe; Schlosser, Michael [Research Group of Predictive Diagnostics of the Department of Medical Biochemistry and Molecular Biology and Institute of Pathophysiology, Ernst Moritz Arndt University Greifswald, Greifswalder Str. 11c, D-17495 Karlsburg (Germany); Zippel, Roland, E-mail: schlosse@uni-greifswald.d [Department of Surgery, Elbland Hospital Center, Weinbergstr. 8, D-01589 Riesa (Germany)

    2010-10-01

    Intima hyperplasia, resulting from extracellular matrix (ECM) secretion, can lead to vascular prosthesis occlusion and is a major problem in vascular surgery. Fibronectin might contribute to ongoing ECM secretion. However, the exact role of fibronectin and its influence on neointima formation remains unclear. This study was aimed at investigating the time course of the fibronectin area fraction and neointima formation following the functional implantation of three different polyester vascular prostheses into pigs. The infrarenal aorta from 15 animals (n = 5/group) was replaced by prosthesis segments with low, medium and high primary porosity. After 7, 14, 21, 28 and 116 days, the prostheses were morphometrically examined. Overall, the fibronectin area fraction was inversely correlated with the neointima thickness, demonstrating high fibronectin levels in the early phase (days 7 and 14) and low levels in the later phase with almost complete neointima formation (days 21-116). Throughout the study, fibronectin levels were highest at the proximal anastomosis region. The low porosity prosthesis had the highest fibronectin area fraction and a delayed neointima formation in the middle phase (days 21 and 28) but the highest neointima lining on day 116. The results indicate a relationship between fibronectin and neointima formation with the prosthesis porosity, demonstrating the importance of the textile design for tissue reactions following implantation.

  9. The Association of Long-Functioning Hemodialysis Vascular Access with Prevalence of Left Ventricular Hypertrophy in Kidney Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Aureliusz Kolonko

    2014-01-01

    Full Text Available Left ventricular hypertrophy (LVH is frequently observed in chronic dialysis patients and is also highly prevalent in kidney transplant recipients. This study evaluates the impact of long-functioning hemodialysis vascular access on LVH in single center cohort of kidney transplant recipients. 162 patients at 8.7 ± 1.8 years after kidney transplantation were enrolled. Echocardiography, carotid ultrasound, and assessment of pulse wave velocity were performed. LVH was defined based on left ventricular mass (LVM indexed for body surface area (BSA and height2.7. There were 67 patients with and 95 without patent vascular access. Both study groups were comparable with respect to gender, age, duration of dialysis therapy, and time after transplantation, kidney graft function, and cardiovascular comorbidities. Patients with patent vascular access were characterized by significantly elevated LVM and significantly greater percentage of LVH, based on LVMI/BSA (66.7 versus 48.4%, P=0.02. OR for LVH in patients with patent vascular access was 2.39 (1.19–4.76, P=0.01. Regression analyses confirmed an independent contribution of patent vascular access to higher LVM and increased prevalence of LVH. We concluded that long-lasting patent hemodialysis vascular access after kidney transplantation is associated with the increased prevalence of LVH in kidney transplant recipients.

  10. Vascular access site complication in transfemoral coronary angiography between uninterrupted warfarin and heparin bridging.

    Science.gov (United States)

    Wongcharoen, Wanwarang; Pinyosamosorn, Kittipong; Gunaparn, Siriluck; Boonnayhun, Suchada; Thonghong, Tasalak; Suwannasom, Pannipa; Phrommintikul, Arintaya

    2017-08-01

    Warfarin discontinuation with heparin bridging is a common practice in patients receiving warfarin prior to elective coronary angiography (CAG). The uninterrupted warfarin strategy has been suggested to be alternative option for patients with high thromboembolic risk. Therefore, we aimed to assess the safety of elective transfemoral CAG during uninterrupted warfarin therapy compared to heparin bridging. This study was a randomized open-label design with blinded event evaluation. The 110 consecutive patients (age ≥ 18 years) receiving warfarin before the planned transfemoral CAG were randomly assigned to either heparin bridging or uninterrupted warfarin with targeted INR (2.0-3.0). The primary outcome was the incidence of major vascular access site complications. The baseline characteristics were comparable between two groups (mean age was 60.1 ± 7.8 years, 49 males). The mean INR on the day of CAG of heparin bridging and uninterrupted warfarin groups was 1.2 ± 0.3 and 2.2 ± 0.5 (P warfarin patients (P = 0.243). The total vascular access site complications occurred in 6 (10.9%) heparin-bridging and one (1.8%) uninterrupted warfarin patients (P = 0.113). No patient developed either other bleeding or thromboembolic events during 7 days after CAG. We demonstrated that an uninterrupted warfarin strategy did not increase vascular access site complications in patients undergoing transfemoral CAG compared to heparin bridging therapy. Due to the safety and the ease of uninterrupted warfarin strategy, this approach should be encouraged in patients receiving long-term warfarin who undergo elective transfemoral CAG. © 2017, Wiley Periodicals, Inc.

  11. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  12. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

    Science.gov (United States)

    Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin

    2015-08-01

    This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.

  13. Development and Validation of a Preprocedural Risk Score to Predict Access Site Complications After Peripheral Vascular Interventions Based on the Vascular Quality Initiative Database

    Directory of Open Access Journals (Sweden)

    Daniel Ortiz

    2016-01-01

    Full Text Available Purpose: Access site complications following peripheral vascular intervention (PVI are associated with prolonged hospitalization and increased mortality. Prediction of access site complication risk may optimize PVI care; however, there is no tool designed for this. We aimed to create a clinical scoring tool to stratify patients according to their risk of developing access site complications after PVI. Methods: The Society for Vascular Surgery’s Vascular Quality Initiative database yielded 27,997 patients who had undergone PVI at 131 North American centers. Clinically and statistically significant preprocedural risk factors associated with in-hospital, post-PVI access site complications were included in a multivariate logistic regression model, with access site complications as the outcome variable. A predictive model was developed with a random sample of 19,683 (70% PVI procedures and validated in 8,314 (30%. Results: Access site complications occurred in 939 (3.4% patients. The risk tool predictors are female gender, age > 70 years, white race, bedridden ambulatory status, insulin-treated diabetes mellitus, prior minor amputation, procedural indication of claudication, and nonfemoral arterial access site (model c-statistic = 0.638. Of these predictors, insulin-treated diabetes mellitus and prior minor amputation were protective of access site complications. The discriminatory power of the risk model was confirmed by the validation dataset (c-statistic = 0.6139. Higher risk scores correlated with increased frequency of access site complications: 1.9% for low risk, 3.4% for moderate risk and 5.1% for high risk. Conclusions: The proposed clinical risk score based on eight preprocedural characteristics is a tool to stratify patients at risk for post-PVI access site complications. The risk score may assist physicians in identifying patients at risk for access site complications and selection of patients who may benefit from bleeding avoidance

  14. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    Science.gov (United States)

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  15. Permanent vascular access survival in children on long-term chronic hemodialysis.

    Science.gov (United States)

    Briones, Liliana; Diaz Moreno, Alexia; Sierre, Sergio; Lopez, Laura; Lipsich, José; Adragna, Marta

    2010-09-01

    The aim of this study is to report a single-center experience regarding the management and outcome of permanent vascular accesses (VA) in children on chronic hemodialysis (HD). We analyzed the survival of permanent VA in 79 pediatric patients with end-stage renal disease patients on chronic HD between January 2000 and December 2008. One hundred and thirty-seven VA [89 native fistulas (AVFs) and 48 grafts (AVGs)] were created in 79 children. The creation of AVFs was significantly more frequent in children weighing >25 kg and AVGs in children weighing <25 kg (p = 0.003). The 1-year primary patency rate was 50% for AVF and 30% for AVG. The secondary patency rates at 1, 2, and 3 years for AVFs were 73, 50, and 20% and for AVGs were 64, 36, and 20%, respectively. The total number of surgical and endovascular interventions was significantly higher in AVGs (p Access stenosis, thrombosis and infection episodes occurred more frequently in AVG (p = 0.02). VAs had a high rate of interventions. Our study demonstrated better results of AVFs formation over AVGs, for long-term HD access in pediatrics. Surveillance and radiologic procedures are necessary for early detection and treatment of access complications in order to extend access survival.

  16. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    Energy Technology Data Exchange (ETDEWEB)

    García-Medina, J., E-mail: josegmedina57@gmail.com [“Reina Sofia” University Hospital, Vascular and Interventional Radiology Unit, Department of Radiology (Spain); García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com [University of Murcia, Faculty of Medicine (Spain)

    2017-05-15

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

  17. Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

    International Nuclear Information System (INIS)

    Powell, Steven; Narlawar, Ranjeet; Odetoyinbo, Tolulola; Littler, Peter; Oweis, Deyana; Sharma, Ajay; Bakran, Ali

    2010-01-01

    The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19

  18. The unsuitability of implantable Doppler probes for the early detection of renal vascular complications - a porcine model for prevention of renal transplant loss

    DEFF Research Database (Denmark)

    Amdisen, Chris; Jespersen, Bente; Møldrup, Ulla

    2017-01-01

    Abstract Background: Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe...... and microdialysis for fast detection of vascular occlusion. Methods: In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were....../3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular...

  19. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats.

    Science.gov (United States)

    Sá, Jairo Zacchê de; Aguiar, José Lamartine de Andrade; Cruz, Adriana Ferreira; Schuler, Alexandre Ricardo Pereira; Lima, José Ricardo Alves de; Marques, Olga Martins

    2012-12-01

    To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005), 1 and 4 (p=0.024), 2 and 3 (p=0.003), 2 and 4 (p=0.001). These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.

  20. Looking into the effect of Diabetes Mellitus on Vascular Access in Haemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Stavroula Tsinikori

    2017-03-01

    Full Text Available Introduction: The creation and maintenance of a good vascular access is mandatory for a successful haemodialysis sessions and the survival of a Chronic Kidney Disease patient. Aim: The aim of the present cross-sectional study was to look into the vascular access complications in haemodialysed patients with or without Diabetes Mellitus (DM and to find any possible correlation of these complications with Diabetes Mellitus. Methods: For this cross-sectional study data from patients’ records of private Dialysis Unit (n=77 and a big General Hospital in a Northern Greece city (n=33 were studied. Demographics, data on medication therapy and vascular access (area, type, dialysis parameters and complications were recorded. Statistical analysis was performed with SPSS 20.0. Results: The sample was 66.7 (±12.5 years old, mainly male (58%, n=58 and on dialysis for 37.3 (±34.3 months. DM was the primary disease of 53% (n=53 of the patients and Hypertension for 13% (n=13,whereas the mean of comorbidities was 5,3 (±2,6. Thirty-seven patients (37% had more than one VA created or placed. On the total of the sample (n=100 156 VA were accessed with the 63% (n=63 of them with arteriovenous fistula (AVF, 35% (n=35 with central venous catheter (CVC and 2% (n=2 with arteriovenous graft (AVG. A statistical significance (U=2560,5, p=0,1 was found regarding the number of VA of the two group of patients (DM=2,2 VA, non DM=1,8. On survival analysis it was found that DM increases the relative risk of “death” of a VA with odds ratio of 1,7 (95% confidence interval 1,1-2,6. Conclusions: DM, as primary disease or co-morbidity, in haemodialysis patients affects negatively the VA survival. Effective blood glucose control, management and methods of puncturing VA play a crucial role in maintaining the VA in DM haemodialysis patients.

  1. The Initial Vascular Access Type Contributes to Inflammation in Incident Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Mala Sachdeva

    2012-01-01

    Full Text Available Background. The contribution of the hemodialysis (HD vascular access type to inflammation is unclear. Methods. We conducted a prospective observational study in an incident HD population. C-reactive protein (CRP, interleukin-6 (IL-6, and interferon-γ-induced protein (IP-10 were measured before and at 6-time points after access placement for 1 year. Results. Sixty-four incident HD patients were included (tunneled catheter (TC, =40, arteriovenous fistula (AVF, =14, and arteriovenous graft (AVG, =10. A mixed effects model was performed to adjust for age, sex, race, coronary artery disease, diabetes mellitus, infections, access thrombosis, initiation of HD, and days after access surgery. In comparison to AVFs, the presence of a TC was associated with significantly higher levels of CRP (=0.03, IL-6 (=0.07, and IP-10 (=0.03. The presence of an AVG was associated with increases in CRP (=0.01 and IP-10 (=0.07. Conclusions. Patients who initiate HD with a TC or an AVG have a heightened state of inflammation, which may contribute to the excess 90-day mortality after HD initiation.

  2. Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant.

    Science.gov (United States)

    Mastinu, Enzo; Doguet, Pascal; Botquin, Yohan; Hakansson, Bo; Ortiz-Catalan, Max

    2017-08-01

    Despite the technological progress in robotics achieved in the last decades, prosthetic limbs still lack functionality, reliability, and comfort. Recently, an implanted neuromusculoskeletal interface built upon osseointegration was developed and tested in humans, namely the Osseointegrated Human-Machine Gateway. Here, we present an embedded system to exploit the advantages of this technology. Our artificial limb controller allows for bioelectric signals acquisition, processing, decoding of motor intent, prosthetic control, and sensory feedback. It includes a neurostimulator to provide direct neural feedback based on sensory information. The system was validated using real-time tasks characterization, power consumption evaluation, and myoelectric pattern recognition performance. Functionality was proven in a first pilot patient from whom results of daily usage were obtained. The system was designed to be reliably used in activities of daily living, as well as a research platform to monitor prosthesis usage and training, machine-learning-based control algorithms, and neural stimulation paradigms.

  3. Complications after percutaneous placement of totally implantable venous access ports in the forearm

    International Nuclear Information System (INIS)

    Goltz, J.P.; Petritsch, B.; Thurner, A.; Hahn, D.; Kickuth, R.

    2012-01-01

    This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.

  4. Prognostic Factors Influencing the Patency of Hemodialysis Vascular Access: Literature Review and Novel Therapeutic Modality by Far Infrared Therapy

    Directory of Open Access Journals (Sweden)

    Chih-Ching Lin

    2009-03-01

    Full Text Available In Taiwan, more than 85% of patients with end-stage renal disease undergo maintenance hemodialysis (HD. The native arteriovenous fistula (AVF accounts for a prevalence of more than 80% of the vascular access in our patients. Some mechanical factors may affect the patency of hemodialysis vascular access, such as surgical skill, puncture technique and shear stress on the vascular endothelium. Several medical factors have also been identified to be associated with vascular access prognosis in HD patients, including stasis, hypercoagulability, endothelial cell injury, medications, red cell mass and genotype polymorphisms of transforming growth factor-β1 and methylene tetrahydrofolate reductase. According to our previous study, AVF failure was associated with a longer dinucleotide (GTn repeat (n ≥ 30 in the promoter of the heme oxygenase-1 (HO-1 gene. Our recent study also demonstrated that far-infrared therapy, a noninvasive and convenient therapeutic modality, can improve access flow, inflammatory status and survival of the AVF in HD patients through both its thermal and non-thermal (endothelial-improving, anti-inflammatory, antiproliferative, antioxidative effects by upregulating NF-E2-related factor-2-dependent HO-1 expression, leading to the inhibition of expression of E-selectin, vascular cell adhesion molecule-1, and intercellular adhesion molecule-1.

  5. Improving Access for Pediatric and Adult Cochlear Implant Candidates in Ontario

    Directory of Open Access Journals (Sweden)

    Yvonne Emily James

    2016-10-01

    Full Text Available In 2011, the Ontario Ministry of Health and Long-Term Care announced the one-time allocation of $5.9 million to be shared by cochlear implant programs at five Ontario hospitals. The primary goal of this reform was to address cochlear implant wait times. More specifically, this funding was aimed at reducing adult wait times by 50% and to completely eliminate pediatric waiting lists. Prior to this funding, wait times for pediatric and adult cochlear implants were known to exceed four years. The funding was provided in response to a growing body of research that demonstrates increased speech perception and vocabulary among pediatric recipients, and pressure from parents of children on cochlear implant waiting lists, surgeons and other involved healthcare providers (e.g., auditory verbal therapists, audiologists, and speech language pathologists. The decision to increase funding was also influenced by government stakeholders who believed this one-time investment would be returned as pediatric patients reach adulthood and are better equipped to participate in mainstream (i.e., hearing society. While this one-time funding model has the potential to eliminate wait times for pediatric patients, thereby ensuring these children can access therapeutic services as early as possible, it does not address the future of cochlear implant waiting lists or the capacity of health human resources to absorb this sudden and unprecedented influx of pediatric patients.

  6. Cilostazol May Improve Maturation Rates and Durability of Vascular Access for Hemodialysis.

    Science.gov (United States)

    Russell, Todd E; Kasper, Gregory C; Seiwert, Andrew J; Comerota, Anthony J; Lurie, Fedor

    2017-04-01

    Cilostazol is effective in controlling pathophysiological pathways similar or identical to those involved in nonmaturation and failure of the arteriovenous access. This case-control study examined whether cilostazol would improve maturation rates and durability of vascular access for hemodialysis. The treatment group included 33 patients who received cilostazol for ≥30 days prior to creation of a dialysis access and continued with cilostazol therapy for ≥60 days after surgery. The matched (gender, age, race, diabetes, and the year of surgery) control group included 116 patients who underwent the same procedure but did not receive cilostazol prior to and at least 3 months after surgery. Primary outcomes were maturation and, for those that matured, time of functioning access, defined as the time from the first use to irreparable failure of the access. Secondary outcomes were time to maturation, complications, and time to first complication. Study group patients were 3.8 times more likely to experience fistula maturation compared to the controls (88% vs 66%, RR = 3.8, 95% confidence interval: 1.3-11.6, P = .016). Fewer patients in the study group had complications (76% vs 92%, P = .025), and the time from construction of the fistula to the first complication was longer (345.6 ± 441 days vs 198.3 ± 185.0 days, P = .025). Time to maturation was similar in both groups (119.3 ± 62.9 days vs 100.2 ± 61.7 days, P = .2). However, once matured, time to failure was significantly longer in the treatment group (903.7 ± 543.6 vs 381.6 ± 317.2 days, P = .001). Multivariate analysis confirmed that the likelihood of maturation was significantly higher in the treatment group patients. These results suggest that dialysis access patients may benefit from preoperative and postoperative cilostazol therapy. If confirmed by a randomized trial, this treatment will have a major beneficial impact on patients dependent on a well-functioning access for their hemodialysis.

  7. Inherited protein S deficiency due to a novel nonsense mutation in the PROS1 gene in the patient with recurrent vascular access thrombosis: A case report

    Directory of Open Access Journals (Sweden)

    Eun Jin Cho

    2012-03-01

    Full Text Available Vascular access thrombosis is one of the major causes of morbidity in patients maintained on chronic hemodialysis. Thrombophilia has been recognized as a risk factor of vascular access thrombosis. The authors report a case of inherited protein S deficiency associated with vascular access thrombotic events. DNA sequence analysis of the PROS1 gene identified a novel heterozygous nonsense mutation in exon 10 by transition of AAG (lysine to TAG (stop codon at codon 473 (c.1417A>T, p.K473X. Results from the study suggest that the inherited protein S deficiency due to a PROS1 gene mutation may cause vascular access thrombosis in hemodialysis patients.

  8. Survey of home hemodialysis patients and nursing staff regarding vascular access use and care.

    Science.gov (United States)

    Spry, Leslie A; Burkart, John M; Holcroft, Christina; Mortier, Leigh; Glickman, Joel D

    2015-04-01

    Vascular access infections are of concern to hemodialysis patients and nurses. Best demonstrated practices (BDPs) have not been developed for home hemodialysis (HHD) access use, but there have been generally accepted practices (GAPs) endorsed by dialysis professionals. We developed a survey to gather information about training provided and actual practices of HHD patients using the NxStage System One HHD machine. We used GAP to assess training used by nurses to teach HHD access care and then assess actual practice (adherence) by HHD patients. We also assessed training and adherence where GAPs do not exist. We received a 43% response rate from patients and 76% response from nurses representing 19 randomly selected HHD training centers. We found that nurses were not uniformly instructing HHD patients according to GAP, patients were not performing access cannulation according to GAP, nor were they adherent to their training procedures. Identification of signs and symptoms of infection was commonly trained appropriately, but we observed a reluctance to report some signs and symptoms of infection by patients. Of particular concern, when aggregating all steps surveyed, not a single nurse or patient reported training or performing all steps in accordance with GAP. We also identified practices for which there are no GAPs that require further study and may or may not impact outcomes such as infection. Further research is needed to develop strategies to implement and expand GAP, measure outcomes, and ultimately develop BDP for HHD to improve infectious complications. © 2014 The Authors. Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.

  9.  Evaluation of the humoral and cellular immune responses after implantation of a PTFE vascular prosthesis.

    Science.gov (United States)

    Skóra, Jan; Pupka, Artur; Dorobisz, Andrzej; Barć, Piotr; Korta, Krzysztof; Dawiskiba, Tomasz

    2012-07-02

    The experiment was designed in order to determine the immunological processes that occur during the healing in synthetic vascular grafts, especially to establish the differences in the location of the complement system proteins between the proximal and distal anastomosis and the differences in the arrangement of inflammatory cells in those anastomoses. The understanding of those processes will provide a true basis for determining risk factors for complications after arterial repair procedures. The experiment was carried out on 16 dogs that underwent implantation of unilateral aorto-femoral bypass with expanded polytetrafluoroethylene (ePTFE). After 6 months all animals were euthanized to dissect the vascular grafts. Immunohistochemical assays and electron microscopic examinations were performed. Immunohistochemical findings in the structure of neointima between anastomoses of vascular prostheses demonstrated significant differences between humoral and cellular responses. The area of proximal anastomosis revealed the presence of fibroblasts, but no macrophages were detected. The histological structure of the proximal anastomosis indicates that inflammatory processes were ended during the prosthesis healing. The immunological response obtained in the distal anastomosis corresponded to the chronic inflammatory reaction with the presence of macrophages, myofibroblasts and deposits of complement C3. The identification of differences in the presence of macrophages and myofibroblasts and the presence of the C3 component between the anastomoses is the original achievement of the present study. In the available literature, no such significant differences have been shown so far in the humoral and cellular immune response caused by the presence of an artificial vessel in the arterial system.

  10. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    International Nuclear Information System (INIS)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae

    2017-01-01

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening

  11. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-05-15

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening.

  12. The effect of bioresorbable vascular scaffold implantation on distal coronary endothelial function in dyslipidemic swine with and without diabetes.

    Science.gov (United States)

    van den Heuvel, Mieke; Sorop, Oana; van Ditzhuijzen, Nienke S; de Vries, René; van Duin, Richard W B; Peters, Ilona; van Loon, Janine E; de Maat, Moniek P; van Beusekom, Heleen M; van der Giessen, Wim J; Jan Danser, A H; Duncker, Dirk J

    2018-02-01

    We studied the effect of bioresorbable vascular scaffold (BVS) implantation on distal coronary endothelial function, in swine on a high fat diet without (HFD) or with diabetes (DM+HFD). Five DM+HFD and five HFD swine underwent BVS implantation on top of coronary plaques, and were studied six months later. Conduit artery segments >5mm proximal and distal to the scaffold and corresponding segments of non-scaffolded coronary arteries, and segments of small arteries within the flow-territory of scaffolded and non-scaffolded arteries were harvested for in vitro vasoreactivity studies. Conduit segments proximal and distal of the BVS edges showed reduced endothelium-dependent vasodilation as compared to control vessels (p≤0.01), with distal segments being most prominently affected(p≤0.01). Endothelial dysfunction was only observed in DM±HFD swine and was principally due to a loss of NO. Endothelium-independent vasodilation and vasoconstriction were unaffected. Surprisingly, segments from the microcirculation distal to the BVS showed enhanced endothelium-dependent vasodilation (pswine, and did not appear to be either NO- or EDHF-mediated. Six months of BVS implantation in DM+HFD swine causes NO-mediated endothelial dysfunction in nearby coronary segments, which is accompanied by a, possibly compensatory, increase in endothelial function of the distal microcirculation. Endothelial dysfunction extending into coronary conduit segments beyond the implantation-site, is in agreement with recent reports expressing concern for late scaffold thrombosis and of early BVS failure in diabetic patients. Copyright © 2017. Published by Elsevier B.V.

  13. The benefit of non contrast-enhanced magnetic resonance angiography for predicting vascular access surgery outcome : a coomputer model perspective

    NARCIS (Netherlands)

    Merkx, M.A.G.; Huberts, W.; Bosboom, E.M.H.; Bode, A.S.; Bescos, J.O.; Tordoir, J.H.M.; Breeuwer, M.; Vosse, van de F.N.

    2013-01-01

    Introduction Vascular access (VA) surgery, a prerequisite for hemodialysis treatment of end-stage renal-disease (ESRD) patients, is hampered by complication rates, which are frequently related to flow enhancement. To assist in VA surgery planning, a patient-specific computer model for postoperative

  14. A comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures.

    Science.gov (United States)

    Echeverria, Angela; Krajcer, Zvonimir

    2016-01-01

    Vascular closure devices allow for early sheath removal, allowing for earlier patient mobilization The Boomerang vascular access management system does not alter arterial integrity for future interventions Access site complications provide significant morbidity in diagnostic and therapeutic interventions. © 2016 Wiley Periodicals, Inc.

  15. Retrospective analysis of 271 arteriovenous fistulas as vascular access for hemodialysis

    Directory of Open Access Journals (Sweden)

    P Sahasrabudhe

    2013-01-01

    Full Text Available This report describes our experience of arteriovenous fistula (AVF creation as vascular access for hemodialysis (HD. Study has been carried out in Deenanath Mangeshkar Hospital, Pune from January 2004 to December 2009. A total of 271 AVFs were created in 249 patients. Maximum follow up was 7 years and minimum was 1 year. In this study of 271 cases of AVFs, there were 196 (72.3% successful cases and 75 (27.7% failures. Basilic vein was used in 77 (28.4% cases, cephalic vein in 186 (68.6%, and antecubital vein in 8 (3% cases. End (vein to side (artery anastomosis was done in 170 (63% cases. Side to side anastomosis was done in 100 (37% cases. On table bruit was present in 244 (90% and thrill in 232 (85.6% cases. During dialysis, flow rate >250 ml/min was obtained in 136 (50.4% cases. In complications, 16 (5.9% patients developed distal edema, 32 (11.8% developed steal phenomenon. Presence of on table thrill and bruit are indicators of successful AVF. If vein diameter is <2 mm, chances of AVF failure are high. During proximal side to side fistula between antecubital/basilic vein and brachial artery, breaking of first valve toward wrist helps to develop distal veins in forearm by retrograde flow. This technique avoids requirement of superficialization of basilic vein in arm.

  16. Screening needs and expectations of patients with vascular access due to chronic hemodialysis

    Directory of Open Access Journals (Sweden)

    Tanja Carli

    2016-12-01

    Full Text Available There is a lack of data about daily difficulties and life quality, especially among young patients having arteriovenous fistula (AVF affected by (pseudoaneurysm. In this retrospective cohort study, 195 patients with AVF were followed up from May to June 2015. An unstandardized questionnaire was used for the evaluation of patients’ screening needs and expectations. Retired married men in their sixties, with completed secondary education, represented the majority of patients with AVF in this study. The patients had a positive attitude towards the disease and AVF, and they received the majority of information related to the care and treatment of AVF from the medical personnel and doctors in selected dialysis centers. Employed, well-educated single men, aged between 21 and 40 years, had the highest interest in having an aesthetic correction of AVF, especially due to the formation of (pseudoaneurysm at the AVF site. Establishment of rules for reconstructive procedures of AVF, once circulatory and hemodynamic stability is achieved after renal transplantation, is suggested in addition to establishing criteria for determining vascular access affected by (pseudoaneurysm.

  17. Different Effects of Implanting Sensory Nerve or Blood Vessel on the Vascularization, Neurotization, and Osteogenesis of Tissue-Engineered Bone In Vivo

    Science.gov (United States)

    Fan, Jun-jun; Mu, Tian-wang; Qin, Jun-jun; Bi, Long; Pei, Guo-xian

    2014-01-01

    To compare the different effects of implanting sensory nerve tracts or blood vessel on the osteogenesis, vascularization, and neurotization of the tissue-engineered bone in vivo, we constructed the tissue engineered bone and implanted the sensory nerve tracts (group SN), blood vessel (group VB), or nothing (group Blank) to the side channel of the bone graft to repair the femur defect in the rabbit. Better osteogenesis was observed in groups SN and VB than in group Blank, and no significant difference was found between groups SN and VB at 4, 8, and 12 weeks postoperatively. The neuropeptides expression and the number of new blood vessels in the bone tissues were increased at 8 weeks and then decreased at 12 weeks in all groups and were highest in group VB and lowest in group Blank at all three time points. We conclude that implanting either blood vessel or sensory nerve tract into the tissue-engineered bone can significantly enhance both the vascularization and neurotization simultaneously to get a better osteogenesis effect than TEB alone, and the method of implanting blood vessel has a little better effect of vascularization and neurotization but almost the same osteogenesis effect as implanting sensory nerve. PMID:25101279

  18. Endometrial signals improve embryo outcome: functional role of vascular endothelial growth factor isoforms on embryo development and implantation in mice.

    Science.gov (United States)

    Binder, N K; Evans, J; Gardner, D K; Salamonsen, L A; Hannan, N J

    2014-10-10

    Does vascular endothelial growth factor (VEGF) have important roles during early embryo development and implantation? VEGF plays key roles during mouse preimplantation embryo development, with beneficial effects on time to cavitation, blastocyst cell number and outgrowth, as well as implantation rate and fetal limb development. Embryo implantation requires synchronized dialog between maternal cells and those of the conceptus. Following ovulation, secretions from endometrial glands increase and accumulate in the uterine lumen. These secretions contain important mediators that support the conceptus during the peri-implantation phase. Previously, we demonstrated a significant reduction of VEGFA in the uterine cavity of women with unexplained infertility. Functional studies demonstrated that VEGF significantly enhanced endometrial epithelial cell adhesive properties and embryo outgrowth. Human endometrial lavages (n = 6) were obtained from women of proven fertility. Four-week old Swiss mice were superovulated and mated with Swiss males to obtain embryos for treatment with VEGF in vitro. Preimplantation embryo development was assessed prior to embryo transfer (n = 19-30/treatment group/output). Recipient F1 female mice (8-12 weeks of age) were mated with vasectomized males to induce pseudopregnancy and embryos were transferred. On Day 14.5 of pregnancy, uterine horns were collected for analysis of implantation rates as well as placental and fetal development (n = 14-19/treatment). Lavage fluid was assessed by western immunoblot analysis to determine the VEGF isoforms present. Mouse embryos were treated with either recombinant human (rh)VEGF, or VEGF isoforms 121 and 165. Preimplantation embryo development was quantified using time-lapse microscopy. Blastocysts were (i) stained for cell number, (ii) transferred to wells coated with fibronectin to examine trophoblast outgrowth or (iii) transferred to pseudo pregnant recipients to analyze implantation rates, placental and

  19. Vascular mapping of the retroauricular skin - proposal for a posterior superior surgical incision for transcutaneous bone-conduction hearing implants.

    Science.gov (United States)

    Perenyi, Adam; Bere, Zsofia; Jarabin, Janos; Sztano, Balazs; Kukla, Edit; Bikhazi, Ziad; Tiszlavicz, Laszlo; Toth, Ferenc; Kiss, Jozsef Geza; Rovo, Laszlo

    2017-01-17

    Passive transcutaneous osseointegrated hearing implant systems have become increasingly popular more recently. The area over the implant is vulnerable due to vibration and pressure from the externally worn sound processor. Good perfusion and neural integrity has the potential to reduce complications. The authors' objective was to determine the ideal surgical exposure to maintain perfusion and neural integrity and decrease surgical time as a result of reduced bleeding. The vascular anatomy of the temporal-parietal soft tissue was examined in a total of 50 subjects. Imaging diagnostics included magnetic resonance angiography in 12 and Doppler ultrasound in 25 healthy subjects to reveal the arterial network. Cadaver dissection of 13 subjects formed the control group. The prevalence of the arteries were statistically analyzed with sector analysis in the surgically relevant area. The main arterial branches of this region could be well identified with each method. Statistical analysis showed that the arterial pattern was similar in all subjects. The prevalence of major arteries is low in the upper posterior area though large in proximity to the auricle region. Diverse methods indicate the advantages of a posterior superior incision because the major arteries and nerves are at less risk of damage and best preserved. Although injury to these structures is rare, when it occurs, the distal flow is compromised and the peri-implant area is left intact. Hand-held Doppler is efficient and cost-effective in finding the best position for incision, if necessary, in subjects with a history of surgical stress to the retroauricular skin. This was a non-interventional study.

  20. Usefulness of Totally Implantable Central Venous Access Devices in Elderly Patients: A Retrospective Study.

    Science.gov (United States)

    Imaoka, Yuki; Kuranishi, Fumito; Ogawa, Yoshiteru

    2018-01-01

    The need for totally implantable central venous access devices (TICVADs) has increased with increased opportunities in the use of chemotherapy and parenteral nutrition. This study aimed to determine the outcomes of TICVAD implantation and use in patients aged ≥85 years. Between January 2010 and August 2016, 117 patients underwent TICVAD implantation and their records were retrospectively reviewed. Participants were divided into 2 groups (plus-85 and sub-85 groups). Fifty-five patients (47.0%) had solid organ cancer alone; 35 patients (29.9%) had cerebrovascular or cranial nerve disease. The average follow-up period was 201 (2-1,620) days. Major complications were identified in 6 (14.6%) plus-85 patients and 11 (14.5%) sub-85 patients (p = 0.9813). Catheter-related infections developed in 3 plus-85 (7.3%) and 4 sub-85 patients (5.3%; p = 0.6549). There were no significant group differences in hematoma, pneumothorax, occlusion, and removal rates. In plus-85 patients examined just before surgery and a month after surgery, increased rates of serum albumin and Onodera's prognostic nutritional index were observed in 48% (14/39) and 41% (12/39), respectively. The use of TICVADs in the plus-85 group resulted in effective outcomes. The results of this retrospective study support the wider use of TICVADs in patients aged ≥85 years. © 2018 S. Karger AG, Basel.

  1. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  2. Using Polymeric Scaffolds for Vascular Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Alida Abruzzo

    2014-01-01

    Full Text Available With the high occurrence of cardiovascular disease and increasing numbers of patients requiring vascular access, there is a significant need for small-diameter (<6 mm inner diameter vascular graft that can provide long-term patency. Despite the technological improvements, restenosis and graft thrombosis continue to hamper the success of the implants. Vascular tissue engineering is a new field that has undergone enormous growth over the last decade and has proposed valid solutions for blood vessels repair. The goal of vascular tissue engineering is to produce neovessels and neoorgan tissue from autologous cells using a biodegradable polymer as a scaffold. The most important advantage of tissue-engineered implants is that these tissues can grow, remodel, rebuild, and respond to injury. This review describes the development of polymeric materials over the years and current tissue engineering strategies for the improvement of vascular conduits.

  3. Relationship of serum S1P and HC-II levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation

    Directory of Open Access Journals (Sweden)

    Yong Liu

    2017-04-01

    Full Text Available Objective: To study the relationship of serum sphingosine 1-phosphate (S1P and heparin cofactor II (HCII levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation. Methods: 52 patients who received cerebrovascular stent implantation and developed restenosis in our hospital between May 2012 and December 2015 were collected as observation group, and 40 healthy patients with cerebrovascular stent implantation who had re-examination in our hospital during the same period were selected as control group. ELISA method was used to detect serum S1P and HC-II levels as well as vasoactive substance and inflammatory factor contents. Spearman correlation analysis was used to evaluate the relationship of serum S1P and HC-II levels with vasoactive substances and inflammatory factors. Results: Serum S1P and HC-II levels of observation group were lower than those of control group (P<0.05; serum vasoactive substances endothelin (ET, angiotensin II (AngII and thromboxane B2 (TXB2 contents of observation group were higher than those of control group while nitric oxide (NO content was lower than that of control group (P<0.05; serum inflammatory factors hypersensitive C-reactive protein (hs-CRP, interleukin-1 (IL-1, IL-6, IL-8 and IL-11 contents of observation group were higher than those of control group (P<0.05. Serum S1P and HC-II levels in patients with cerebral vascular restenosis after stent implantation were directly correlated with vasoactive substance and inflammatory factor contents. Conclusion: Serum S1P and HC-II levels decrease in patients with cerebral vascular restenosis after stent implantation, and it is an important cause of cerebral vascular dysfunction and systemic inflammatory response.

  4. Permanent vascular access in patients with end-stage renal disease, Brazil Acceso vascular permanente en pacientes renales crónicos terminales en Brasil Acesso vascular permanente em pacientes renais crônicos terminais no Brasil

    Directory of Open Access Journals (Sweden)

    Gisele Macedo da Silva

    2011-04-01

    Full Text Available OBJECTIVE: To assess factors associated with the establishment of permanent vascular access for patients with end-stage renal disease. METHODS: Cross-sectional study conducted in a nationally representative sample of Brazilian end-stage renal disease patients in dialysis and transplant centers during 2007. The sample comprised only patients who received hemodialysis as a primary therapy modality and reported the type of vascular access for their primary hemodialysis treatment (N=2,276. Data were from the TRS Project - "Economic and Epidemiologic Evaluation of Modalities of Renal Replacement Therapy in Brazil". Multiple logistic regression analysis was used to assess factors associated with the establishment of permanent vascular access in these patients. RESULTS: About 30% of the patients studied had an arteriovenous vascular access. The following factors were associated with a lower likelihood of having an arteriovenous vascular access as a primary type of access: time of hemodialysis start since the diagnosis of chronic renal failure OBJETIVO: Analizar factores asociados a la provisión de acceso vascular arteriovenoso en Brasil. MÉTODOS: Estudio transversal, nacionalmente representativo, con pacientes con enfermedad renal crónica terminal acompañados en servicios de diálisis o en centros transplantadores en el año de 2007. La muestra incluyó pacientes que tuvieron la hemodiálisis como primera modalidad de tratamiento y que sabían con que tipo de acceso vascular habían iniciado el tratamiento (N=2.276. Los datos son oriundos del Proyecto TRS - "Evaluación económica-epidemiológica de las modalidades de Terapia renal Sustitutiva en Brasil". Fue utilizada la regresión logística múltiple. RESULTADOS: Aproximadamente 30% de los pacientes tenían acceso vascular arteriovenoso. Los factores asociados a la baja probabilidad de tener acceso vascular arteriovenoso como primer tipo de acceso fueron: tiempo de diagnóstico de enfermedad

  5. Vein of Galen malformation: What to do when vascular access is not feasible?

    Directory of Open Access Journals (Sweden)

    Zenteno Marco

    2014-06-01

    Full Text Available Background: The vein of Galen aneurysmal malformation (GVAM is a rare congenital vascular lesion, with high morbidity and mortality without treatment, endovascular management is the best alternative available today.

  6. Simultaneous Iliac Vein Bovine Pericardial Patch Venoplasty and Creation of PTFE Lower Limb Arteriovenous Fistula Graft for Rescue Vascular Access.

    Science.gov (United States)

    Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun

    2016-10-01

    We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. First-in-man intravenous implantation of stromal vascular fraction in psoriasis: a case study.

    Science.gov (United States)

    Comella, Kristin; Parlo, Michelle; Daly, Rosemary; Dominessy, Kellie

    2018-01-01

    Stromal vascular fraction (SVF) is a mixture of adipose-derived stem cells/mesenchymal stem cells, endothelial/progenitors, pericytes, fibroblasts, and other cells obtained from fat tissue. A small sample of fat or adipose tissue can be obtained under local anesthesia using a cannula. After an enzymatic digestion and centrifugation, the adipocytes (fat cells) are removed to obtain an SVF. Here, we describe the rationale and, to our knowledge, the first clinical implementation of SVF intravenously in a patient with severe psoriasis. Adipose tissue (60 mL) was collected under local anesthesia via a mini-lipoaspirate procedure. The SVF was separated from the adipocytes via centrifugation after an enzymatic digestion. The cells were resuspended in normal saline and injected via bolus push intravenous. The subject was monitored over a period of 12 months for safety (adverse events), medication changes, and quality of life parameters. The patient did not report any safety concerns and did not experience any severe adverse events. The patient demonstrated a significant decrease in symptoms with a noticeable difference in skin quality appearance. Psoriasis area and severity index score went from 50.4 at baseline to 0.3 at 1 month follow-up. Overall, the patient reported improved quality of life and willingness to continue treatments. This successful initial case study demonstrates that this may be a feasible treatment plan for patients suffering from psoriasis.

  8. Comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures: The boomerang™ wire vascular access management trial II.

    Science.gov (United States)

    Goswami, Nilesh J; Smalling, Ronnie G; Sinha, Shantanu; Gammon, Roger S; Ramaiah, Venkatesh G

    2016-01-01

    To evaluate the use of the Boomerang™ Wire as an adjunct to manual compression (MC) in patients requiring diagnostic (Dx) or interventional (Ix) percutaneous procedures. MC remains the standard of care for closure of femoral artery access sites. Adjunctive use of a device to facilitate closure, reduce time to hemostasis (TTH) and ambulation (TTA) without increasing complication rates could reduce costs and hospital resource demands. The Boomerang™ Trial was a prospective, multicenter, randomized, controlled trial comparing use of the Boomerang™ wire, (Cardiva Medical, Sunnyvale, CA) in conjunction with MC versus MC alone to achieve hemostasis in Dx and Ix patients undergoing percutaneous procedures requiring femoral artery access. Endpoints included TTH, TTA, major, and minor access-site related complications. Subjects were randomized 3:1, Boomerang versus MC. No minor or major device-related adverse events were reported. Nondevice related complication rates were 3 (0.9%) in the Boomerang arm (n = 327) and 1 (0.8%) in MC arm (n = 123). Mean TTH for Boomerang vs. MC was 11.2 ± 4.3 vs. 23.2 ± 11 min for Dx (P Boomerang vs. MC was 3.3 ± 3.0 vs. 4.5 ± 2.0 hr (P Boomerang™ use, in conjunction with MC, was associated with low rates of complications and demonstrated that Boomerang™ as an adjunct to MC can significantly decrease TTH and TTA after both Dx and Ix procedures. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage.

    Science.gov (United States)

    Chen, Xiaoyan; Saravelos, Sotirios H; Liu, Yingyu; Huang, Jin; Wang, Chi Chiu; Li, Tin Chiu

    2017-06-01

    Power Doppler in combination with three-dimensional (3D-PD) ultrasonography has been used as a noninvasive tool to evaluate the vascularity. However, it is unclear whether 3D-PD can accurately reflect endometrial vascularization and replace the invasive endometrial biopsy. This study aims to investigate the correlation between 3D-PD and micro vessel morphometric measurement of endometrial vascularity. Twenty-five women with unexplained recurrent miscarriage were recruited for 3D-PD and endometrial biopsy on precisely day LH + 7. Immunohistochemistry using vWF was employed to identify micro vessels in endometrial biopsy specimens followed by the use of morphometric technique to measure the mean vessel diameter and volume fractions. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) assessed by 3D-PD were calculated for both the endometrial and sub-endometrial regions. There were no significant correlations between any of the ultrasonographic measurements (endometrial thickness, endometrial volume, endometrial VI/FI/VFI, sub-endometrial volume, sub-endometrial VI/FI/VFI) and morphometric features (number of micro vessel, mean diameter of micro vessel and volume fraction measurement of vessel). This study indicates that endometrial vascularity assessed by 3D-PD could not be used to reflect changes in micro vessels of the endometrium at the time of embryo implantation in women with unexplained recurrent miscarriage.

  10. Feasibility of power contrast injections and bolus triggering during CT scans in oncologic patients with totally implantable venous access ports of the forearm

    International Nuclear Information System (INIS)

    Goltz, Jan Peter; Machann, Wolfram; Noack, Claudia; Hahn, Dietbert; Kickuth, Ralph

    2011-01-01

    Background: Conventional totally implantable venous access ports (TIVAPs) are not approved for power contrast injections but often remain the only venous access site in oncologic patients. Therefore, these devices can play an important role if patients with a TIVAP are scheduled for a contrast-enhanced computed tomography (ceCT) as vascular access may become more difficult during the course of chemotherapy. Purpose: To evaluate the feasibility and safety of power injections in conventional TIVAPs in the forearm and to analyze the feasibility of bolus triggering during CT scans. Material and Methods: In this retrospective study we analyzed 177 power injections in 141 patients with TIVAPs in the forearm. Between October 2008 and March 2010 all patients underwent power injections (1.5 mL/s, 150 psi) via the TIVAP for ceCT because conventional vascular access via a peripheral vein had failed. Adequate functioning and catheter's tip location after injection were evaluated. Peak injection pressure and attenuation levels of aorta, liver and spleen were analyzed and compared with results of 50 patients who were injected via classical peripheral cannulas (3 mL/s, 300 psi). Feasibility of automatic scan initiation was evaluated. In vitro the port was stressed with 5 mL/s (300 psi). Results: One TIVAP showed tip dislocation with catheter rupture. Three (2.1%) devices were explanted owing to assumed infection within 4 weeks after the injection. Mean injection pressure was 121.9 ±24.1 psi. Triggering with automatic scan initiation succeeded in 13/44 (29.6%) scans. Injection via classical cannulas resulted in significantly higher enhancement (p < 0.05). In vitro the port system tolerated flow rates of up to 5 mL/s, injection pressures of up to 338 psi. Conclusion: Power injection is a safe alternative for patients with TIVAPs in the forearm if classic vascular access ultimately fails. Triggering was successful in one-third of the attempts. Image quality in the arterial phase

  11. The outcome and complications of the DiaTAP bioCarbon button-graft vascular access device in haemodialysis patients: a two-year experience.

    Science.gov (United States)

    Paul, M D; Parfrey, P; Marshall, D; Aldrete, V; Purchase, L; Gault, H

    1986-01-01

    The outcome and complications which developed in 8 hemodialysis patients who received 12 DiaTAP bioCarbon button vascular-access devices were reviewed. All patients had a poor vascular access history. Three of twelve devices have been replaced because of thrombosis and two because of infection. Four patients have had 10 episodes of reduced blood flow. Streptokinase infusion into the DiaTAP button led to improved blood flow in 8 of 10 episodes. The 6-month survival rate of the DiaTAP access device was 67% and the average functioning life was 9.4 months. It was a valuable form of access when others had failed.

  12. 78 FR 38994 - Implanted Blood Access Devices for Hemodialysis; Draft Guidance for Industry and Food and Drug...

    Science.gov (United States)

    2013-06-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0749] Implanted Blood Access Devices for Hemodialysis; Draft Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...

  13. Spatial Release From Masking in Simulated Cochlear Implant Users With and Without Access to Low-Frequency Acoustic Hearing

    Directory of Open Access Journals (Sweden)

    Ben Williges

    2015-12-01

    Full Text Available For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch. Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types.

  14. Device-specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable-polymer metallic drugeluting stents in human coronary arteries. The ESTROFA OCT BVS vs. BP-DES study.

    Science.gov (United States)

    de la Torre Hernandez, Jose Maria; Gonzalo, Nieves; Otaegui, Imanol; Rumoroso, Jose R; Gutiérrez, Hipólito; Alfonso, Fernando; Marti, Gerard; Serrador Frutos, Ana; Brugaletta, Salvatore; Gomez Menchero, Antonio; Garcia Camarero, Tamara; Biagioni, Corina; Escaned, Javier

    2018-06-12

    We sought to compare vascular healing with bioresorbable everolimus-eluting vascular scaffolds (BVS) and drug-eluting stents with bioabsorbable polymers (BP-DES) at 6 and 12 months implanted both in same patients. Multicenter and prospective study including patients with at least two comparable lesions to treat. In every patient both BVS and BP-DES (Synergy™, Orsiro™ or Biomatrix Flex™) were implanted by lesion randomization. Patients included were evaluated with optical coherence tomography at 6 or 12 months (2:1). Finally, 68 patients had examination at 6 months and 27 patients at 12 months. Uncovered struts rates at 6 months were 1.7±3.2% for BVS and 5.3±5.6% for BP-DES (p=0.0001) and at 12 months 0.48±0.72% and 4.8±5% respectively (p=0.001). Rates of strut malapposition were significantly lower with BVS. There was no significant intra-patient correlation BP-DES / BVS for endpoints. Evaginations were more frequent and larger with BVS. Discontinuities in BVS were observed in 19.4% at 6 months and 14.3% at 12 months. Vascular healing with BVS and BP-DES could be more device-specific than patient-specific. At follow-up, BVS presented less uncovered or non-apposed struts than BP-DES but more frequent and larger evaginations. Discontinuities in BVS were relatively frequent at both time points.

  15. Near-infrared vascular imaging in peripheral venous and arterial access

    OpenAIRE

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development and clinical evaluation of the VascuLuminator, a guidance tool for peripheral venous and arterial access by visualizing blood vessels underneath the skin with near-infrared light. In a third to a fif...

  16. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  17. Near-infrared vascular imaging in peripheral venous and arterial access

    NARCIS (Netherlands)

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development

  18. Short- and long-term functional effects of percutaneous transluminal angioplasty in hemodialysis vascular access

    NARCIS (Netherlands)

    J. van der Linden (Joke); J.H. Smits (Johannes); J.H. Assink (Jan Hendrik); D.W. Wolterbeek (Derk); J.J. Zijlstra (Jan); G.H.T. de Jong (Gijs); M.A. van den Dorpel (Marinus); P.J. Blankestijn (Peter)

    2002-01-01

    textabstractThe efficacy of percutaneous transluminal angioplasty (PTA) is usually expressed as the angiographic result. Access flow (Qa) measurements offer a means to quantify the functional effects. This study was performed to evaluate the short-term functional and

  19. Association of vascular access flow with short-term and long-term mortality in chronic haemodialysis patients: a retrospective cohort study

    OpenAIRE

    Wu, Chung-Kuan; Wu, Chia-Lin; Lin, Chia-Hsun; Leu, Jyh-Gang; Kor, Chew-Teng; Tarng, Der-Cherng

    2017-01-01

    Objectives To investigate the impact of vascular access flow (Qa) on vascular and all-cause mortality in chronic haemodialysis (HD) patients. Design Observational cohort study. Setting Single centre. Participants Adult chronic HD patients at the HD unit of Shin Kong Wu Ho-Su Memorial Hospital between 1 January 2003 and 31 December 2003 were recruited. Patients were excluded if they had arteriovenous fistula or arteriovenous graft failure within 3 months before the date of Qa measurement, were...

  20. Pictorial essay: Interventional radiology in the management of hemodialysis vascular access - A single-center experience

    International Nuclear Information System (INIS)

    Mammen, Suraj; Keshava, Shyamkumar N; Moses, Vinu; Babu, Surendra; Varughese, Santhosh

    2012-01-01

    Chronic kidney disease (CKD) is a worldwide public health problem and is associated with high morbidity and mortality. The majority of patients with CKD stage 5 (CKD-5), who cannot undergo renal transplant, depend on maintenance hemodialysis by surgically created access sites. Native fistulae are preferred over grafts due to their longevity. More than half of these vital portals for dialysis access will fail over time. Screening procedures to select high-risk patients before thrombosis or stenosis appears have resulted in aggressive management. These patients are referred for angiographic evaluation and/or therapy. We present the patterns of dialysis-related interventions done in our institution

  1. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  2. Localization of vascular endothelial growth factor (VEGF) and its receptors VEGFR-1 and VEGFR-2 in bovine placentomes from implantation until term

    DEFF Research Database (Denmark)

    Pfarrer, C.D.; Ruziwa, S.D.; Winther, H.

    2006-01-01

    Interactions of vascular endothelial growth factor (VEGF) with its receptors VEGFR-1 and VEGFR-2 promoting angiogenesis have been described in placentation of human, mink and pig. The bovine placenta is multiplex, villous and synepitheliochorial due to migratory trophoblast giant cells (TGC...... reactivity in giant cells. VEGFR-1 was observed in trophoblast and uterine epithelium around implantation. Later, in definite placentomes, VEGFR-1 was localized in TGC near the chorionic plate and in maternal endothelial cells in the center of the placentome. VEGFR-1 and VEGFR-2 were co-localized in uterine...

  3. Lexical-Access Ability and Cognitive Predictors of Speech Recognition in Noise in Adult Cochlear Implant Users

    OpenAIRE

    Kaandorp, Marre W.; Smits, Cas; Merkus, Paul; Festen, Joost M.; Goverts, S. Theo

    2017-01-01

    Not all of the variance in speech-recognition performance of cochlear implant (CI) users can be explained by biographic and auditory factors. In normal-hearing listeners, linguistic and cognitive factors determine most of speech-in-noise performance. The current study explored specifically the influence of visually measured lexical-access ability compared with other cognitive factors on speech recognition of 24 postlingually deafened CI users. Speech-recognition performance was measured with ...

  4. Major femoral vascular access complications after coronary diagnostic and interventional procedures

    DEFF Research Database (Denmark)

    Dencker, Ditte; Pedersen, Frants; Engstrøm, Thomas

    2016-01-01

    surgery within 30 days were collected. Mortality data were collected for minimum 12 months. RESULTS: We identified 130 (0.54%) access complications requiring surgery; 65 pseudoaneurysms (0.28%), 46 arterial occlusions (0.19%), 15 hematomas (nine groin and six retroperitoneal hematomas) (0.06%), and 4...

  5. Incidence and risk factors of infections complications related to implantable venous-access ports

    International Nuclear Information System (INIS)

    Shim, Ji Sue; Seo, Tae Seok; Song, Myung Gyu; Cha, In Ho; Kim, Jun Suk; Choi, Chul Won; Seo, Jae Hong; Oh, Sang Cheul

    2014-01-01

    The purpose of this study was to determine the incidence and risk factors of infections associated with implantable venous access ports (IVAPs.) From August 2003 through November 2011, 1747 IVAPs were placed in our interventional radiology suite. One hundred forty four IVAPs were inserted in patients with hematologic malignancy and 1603 IVAPs in patients with solid tumors. Among them, 40 ports (23 women and 17 men; mean age, 57.1 years; range, 13-83) were removed to treat port-related infections. We evaluated the incidence of port-related infection, patient characteristics, bacteriologic data, and patient progress. Univariable analyses (t test, chi-square test, and Fisher's exact test) and multiple logistic regression analyses were used to determine the risk factors for IVAP related infection. Overall, 40 (2.3%) of 1747 ports were removed for symptoms of infection with an incidence rate of 0.067 events/1000 catheter-days. According to the univariable study, the incidences of infection were seemingly higher in the patients who received the procedure during inpatient treatment (p = 0.016), the patients with hematologic malignancy (p = 0.041), and the patients receiving palliative chemotherapy (p = 0.022). From the multiple binary logistic regression, the adjusted odds ratios of infection in patients with hematologic malignancies and those receiving palliative chemotherapy were 7.769 (p = 0.001) and 4.863 (p = 0.003), respectively. Microorganisms were isolated from 26 (65%) blood samples, and two of the most causative organisms were found to be Staphylococcus (n = 10) and Candida species (n = 7). The underlying hematologic malignancy and the state of receiving palliative chemotherapy were the independent risk factors of IVAP-related infection.

  6. Incidence and risk factors of infections complications related to implantable venous-access ports

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Ji Sue; Seo, Tae Seok; Song, Myung Gyu; Cha, In Ho; Kim, Jun Suk; Choi, Chul Won; Seo, Jae Hong; Oh, Sang Cheul [Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    The purpose of this study was to determine the incidence and risk factors of infections associated with implantable venous access ports (IVAPs.) From August 2003 through November 2011, 1747 IVAPs were placed in our interventional radiology suite. One hundred forty four IVAPs were inserted in patients with hematologic malignancy and 1603 IVAPs in patients with solid tumors. Among them, 40 ports (23 women and 17 men; mean age, 57.1 years; range, 13-83) were removed to treat port-related infections. We evaluated the incidence of port-related infection, patient characteristics, bacteriologic data, and patient progress. Univariable analyses (t test, chi-square test, and Fisher's exact test) and multiple logistic regression analyses were used to determine the risk factors for IVAP related infection. Overall, 40 (2.3%) of 1747 ports were removed for symptoms of infection with an incidence rate of 0.067 events/1000 catheter-days. According to the univariable study, the incidences of infection were seemingly higher in the patients who received the procedure during inpatient treatment (p = 0.016), the patients with hematologic malignancy (p = 0.041), and the patients receiving palliative chemotherapy (p = 0.022). From the multiple binary logistic regression, the adjusted odds ratios of infection in patients with hematologic malignancies and those receiving palliative chemotherapy were 7.769 (p = 0.001) and 4.863 (p = 0.003), respectively. Microorganisms were isolated from 26 (65%) blood samples, and two of the most causative organisms were found to be Staphylococcus (n = 10) and Candida species (n = 7). The underlying hematologic malignancy and the state of receiving palliative chemotherapy were the independent risk factors of IVAP-related infection.

  7. [Surgical learning curve for creation of vascular accesses for haemodialysis: value of medico-radio-surgical collaboration].

    Science.gov (United States)

    Van Glabeke, Emmanuel; Belenfant, Xavier; Barrou, Benoît; Adhemar, Jean-Pierre; Laedrich, Joëlle; Mavel, Marie-Christine; Challier, Emmanuel

    2005-04-01

    Creation of a vascular access (VA) for haemodialysis is a surgical procedure which comprises a failure rate related to the quality of the vessels and the operator's experience. The authors report the first 2 years of a young urologist's experience with this procedure in a local hospital in collaboration with the nephrology team. Patients undergoing creation of VA were divided into 2 chronological groups. The patient's age and gender, the cause of renal failure, the presence of diabetes, clinical examination of the upper limb, preoperative assessment of upper limb vessels, the type of anaesthesia, the operating time and the start of dialysis after the operation, as well as the functional results of the VA at 6 months were studied. Results concerning the patients of the first period were discussed by the operator and the nephrology team. During the first 9 months, 28 patients were operated, corresponding to 36 operations including 32 direct fistulas. Over the following 15 months, 61 patients were operated, with the creation of 63 VAs, including 55 direct fistulas. The failure rate (thrombosis or non-functioning VA) decreased from 32.1% to 11.1% (p=0.07), while the 2 groups were globally comparable. Evaluation of a new surgical procedure shows a number of failures, as for all learning curves. However, it helps to improve the results. Collaboration with nephrologists must comprise a discussion allowing the acceptance of certain failures, as they reflect compliance with a strategy of preservation of the vascular capital and a rational attempt to avoid a non-essential proximal access or bypass graft. The support of a motivated radiology team (preoperative assessment and management of complications) and the assistance of a more experienced operator are essential.

  8. Vascular access and infection prevention and control: a national survey of routine practices in Irish haemodialysis units.

    Science.gov (United States)

    McCann, Margaret; Clarke, Michael; Mellotte, George; Plant, Liam; Fitzpatrick, Fidelma

    2013-04-01

    National and international guidelines recommend the use of effective vascular access (VA) and infection prevention and control practices within the haemodialysis environment. Establishing an arterio-venous fistula (AVF) and preventing central venous catheter (CVC)-related infections are ongoing challenges for all dialysis settings. We surveyed VA and routine infection prevention and control practices in dialysis units, to provide national data on these practices in Ireland. A descriptive survey was emailed to nurse managers at all adult (n = 19) and children (n = 1) outpatient haemodialysis units in the Republic of Ireland. Data collected included AVF formation, CVC insertion and maintenance practices, VA use and surveillance of infection and screening protocols. Nineteen of the 20 units responded to the survey. The AVF prevalence was 49% for 1370 patients in 17 units who provided these data [mean prevalence per unit: 45.7% (SD 16.2)]; the CVC mean prevalence per unit was 52.5% (SD 16.0). Fourteen dialysis units experienced inadequate access to vascular surgical procedures either due to a lack of dedicated theatre time or hospital beds. Six units administered intravenous prophylactic antimicrobials prior to CVC insertion with only two units using a CVC insertion checklist at the time of catheter insertion. In general, dialysis units in Ireland show a strong adherence to national guidelines. Compared with the 12 countries participating in the Dialysis Outcomes Practice Patterns Study (DOPPS 4), in 2010, AVF prevalence in Irish dialysis units is the second lowest. Recommendations include establishing an AVF national prevalence target rate, discontinuing the administration of intravenous prophylactic antimicrobials prior to CVC insertion and promoting the use of CVC insertion checklists.

  9. Comparison of Venae Sectio vs. modified Seldinger Technique for Totally Implantable Access Ports; Portas-trial [ISRCTN:52368201

    Directory of Open Access Journals (Sweden)

    Luntz S

    2006-06-01

    Full Text Available Abstract Background The insertion of a Totally Implantable Access Port (TIAP is a routinely employed technique in patients who need a safe and permanent venous access. The number of TIAP implantations is increasing constantly mainly due to advanced treatment options for malignant diseases. Therefore it is important to identify the implantation technique which has the optimal benefit/risk ratio for the patient. Study design A single-centre, randomized, controlled superiority trial to compare two different TIAP implantation techniques. Sample size: 160 patients will be included and randomized intra-operatively. Eligibility criteria: Age equal or older than 18 years, patients scheduled for primary elective implantation of a TIAP in local anaesthesia and a signed informed consent. Primary endpoint: Primary success rate of the randomized technique. Intervention: Venae Sectio in combination with the Seldinger Technique (guide wire and a peel away sheath will be used to place a TIAP. Reference treatment: Conventional Venae Sectio will be used with a direct insertion of the TIAP without guide wire or peel away sheath. Duration of study: Approximately 20 months. Organisation/Responsibility The trial will be conducted in compliance with the protocol and in accordance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The trial will also be carried out in keeping with local and regulatory requirements. The Klinisches Studienzentrum Chirurgie (KSC – Centre of Clinical Trials in Surgery at the Department of Surgery, University Hospital Heidelberg is responsible for planning and conduction of the trial. Documentation of patient's data will be accomplished via electronical Case Report Files (eCRF with MACRO®-Software by the KSC. Randomization, data management, monitoring and biometry are provided by the independent Koordinierungszentrum f

  10. A comparison of the effect of alcohol and povidone-iodine mixture with alcohol after povidon-iodine in prevention of vascular access inflammation in patients undergoing hemodialysis

    Directory of Open Access Journals (Sweden)

    Bazzi A

    2014-11-01

    Full Text Available Background and Objective: The quality of hemodialysis can be promoted through reducing vascular access complications in these patients. One of the crucial roles of nurses in hemodialysis wards is reducing inflammation and infection of the vascular access. This study was conducted to compare the incidence of inflammation around the vascular access area in patients undergoing hemodialysis between two antiseptic methods of alcohol after povidone-iodine and the combination of alcohol and povidone-iodine. Materials and Method: This clinical trial was performed under the supervision of Mashhad University of Medical Sciences, Iran, after gaining ethical committee approval in 2014. In the present study, 100 participants were selected by convenience sampling method and randomly divided into three groups of combination of alcohol and povidone-iodine (n = 37, alcohol after using povidone-iodine (n = 32, and control group (n = 31. In the intervention groups 1 and 2, vascular access was disinfected using a combination of alcohol and povidone-iodine and alcohol after povidone-iodine, respectively. In the control group, vascular access was disinfected using the method of the related ward. Patients were fully observed for phlebitis occurrence for 12 hemodialysis sessions (1 month. Vascular access was controlled using the Iranian Nurses Association's phlebitis criteria. Data were analyzed using chi-square, ANOVA test, and Fisher's exact test in SPSS version 16. Results: The incidence rate of inflammation in the combination of alcohol and povidone-iodine, alcohol after povidone-iodine, and control groups, respectively, were 46%, 87.9%, and 100%. The incidence rate of inflammation was significantly lower in the combination of alcohol and povidone-iodine compared to the alcohol after povidone-iodine group (P < 0.001. However, no significant differences existed between the alcohol after povidone-iodine and control group. Conclusion: The combination of alcohol and

  11. Current use of ultrasound for central vascular access in children and infants in the Nordic countries--a cross-sectional study

    DEFF Research Database (Denmark)

    Olsen, Thomas C Risom; Rimstad, Ivan Jonassen; Tarpgaard, Mona

    2015-01-01

    . METHODS: A cross-sectional survey using an online questionnaire was distributed to one anaesthesiologist at every hospital in the Nordic countries; a total of 177 anaesthesiologists were contacted from July till August 2012. RESULTS: The use of US for placing central venous catheters (CVCs) seems......PURPOSE: The use of ultrasound (US) guidance for central vascular access in children has been advocated as a safer approach compared to traditional landmark techniques. We therefore collected data on the current use of US for central vascular access in children and infants in the Nordic countries...

  12. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    Science.gov (United States)

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  13. Pinch-off syndrome: transection of implantable central venous access device

    OpenAIRE

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-01-01

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take che...

  14. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study

    Energy Technology Data Exchange (ETDEWEB)

    Otsuki, Shuji; Brugaletta, Salvatore, E-mail: sabrugal@clinic.ub.es; Sabaté, Manel; Shiratori, Yoshitaka; Gomez-Monterrosas, Omar; Scalone, Giancarla; Romero-Villafañe, Sebastian; Hernández-Enríquez, Marco; Freixa, Xavier; Martín-Yuste, Victoria; Masotti, Mónica

    2016-06-15

    Purpose: Second-generation drug-eluting stent (DES) have shown a better safety and efficacy as compared to first generation DES due to an improved vascular healing process. This process has not been so far evaluated in vivo in an overtime fashion by optical coherent tomography (OCT). We sought to evaluate the vascular healing process after everolimus-eluting stent (EES) implantation at 6, 9 and 12 months, by OCT. Methods: Consecutive 36 patients undergoing percutaneous coronary intervention with EES were randomized 1:1:1 to receive OCT imaging at 6 (group A), 9 (group B) or 12-month follow-up (group C). One patient from group C was excluded because of target lesion revascularization at 1-month, whereas 5 patients withdraw the informed consent. Finally, 30 patients were analyzed. Results: Neointimal thickness was not different between 3 groups (group A: 99.50 [94.06–127.79] μm, group B: 107.26 [83.48–133.59] μm, group C: 127.67 [102.51–138.49] μm; p = 0.736). Although the percentage of “uncovered struts” was significantly higher in group A as compared to the other groups (8.0% vs. 4.4% vs. 2.9%, respectively; p = 0.180), the ratio of uncovered to total struts per section < 30% was similar between 3 groups (0.3% vs. 0.3% vs. 0%, respectively; p = 1.000). Conclusion: Healing process following EES implantation seems almost completed at 6-month follow-up. These data, which need to be confirmed in a larger study, may support the decision to shorten dual antiplatelet therapy. - Highlights: • Healing process following everolimus-eluting stent implantation is complete at 6-month • There are no difference in RUTTS > 30% between 6, 9 and 12 months analyses. • This finding may support to shorten dual antiplatelet therapy in this context.

  15. Evidence of increased endometrial vascular permeability at the time of implantation in the short-nosed fruit bat, Cyanopterus sphinx.

    Science.gov (United States)

    Pakrasi, Pranab Lal; Tiwari, Anjana

    2007-09-01

    Early embryonic development and implantation were studied in tropical short-nosed fruit bat Cyanopterus sphinx. We report preimplantation development and embryo implantation. Different stages of cleavage were observed in embryo by direct microscopic examination of fresh embryos after retrieving them either from the oviduct or the uterus at different days, up to the day of implantation. Generally, the embryos enter the uterus at the 8-cell stage. Embryonic development continued without any delay and blastocyst were formed showing attachment to the uterine epithelium at the mesometrial side of the uterus. A distinct blue band was formed in the uterus. The site of blastocyst attachment was visualized as a blue band following intravenous injection of pontamine blue. Implantation occurred 9+/-0.7 days after mating. This study reports that bat embryonic development can be studied like other laboratory animals and that this bat shows blue dye reaction, indicating the site and exact time of implantation. This blue dye reaction can be used to accurately find post-implantational delay. We prove conclusively that this species of tropical bat does not have any type of embryonic diapause.

  16. Long-term Outcome of Peripherally Implanted Venous Access Ports in the Forearm in Female Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Klösges, Laura, E-mail: l.kloesges@uni-bonn.de; Meyer, Carsten, E-mail: carsten.meyer@ukb.uni-bonn.de; Boschewitz, Jack, E-mail: jack.boschewitz@ukb.uni-bonn.de; Andersson, Magnus, E-mail: magnus.andersson@ukb.uni-bonn.de [Universitätsklinikum Bonn, Department of Radiology (Germany); Rudlowski, Christian, E-mail: c.rudlowski@evk.de [Evangelisches Krankenhaus Bergisch Gladbach, Department of Gynecology (Germany); Schild, Hans H., E-mail: hans.schild@ukb.uni-bonn.de [Universitätsklinikum Bonn, Department of Radiology (Germany); Wilhelm, Kai, E-mail: kai.wilhelm@ek-bonn.de [Ev. Kliniken Bonn, Johanniter-Krankenhaus, Department of Radiology (Germany)

    2015-06-15

    PurposeThe aim of this retrospective study was to analyze the long-term outcome of peripherally implanted venous access ports in the forearm at our institution in a female patient collective.MethodsBetween June 2002 and May 2011, a total of 293 female patients with an underlying malignancy had 299 forearm ports implanted in our interventional radiology suite. The mean age of the cohort was 55 ± 12 years (range 26–81 years). The majority of women suffered from breast (59.5 %) or ovarian cancer (28.1 %). Complications were classified as infectious complications, thrombotic and nonthrombotic catheter dysfunction (dislocation of the catheter or port chamber, fracture with/without embolization or kinking of the catheter, port occlusion), and others.ResultsWe analyzed a total of 90,276 catheter days in 248 port systems (47 patients were lost to follow-up). The mean device service interval was 364 days per catheter (range 8–2,132, median 223 days, CI 311–415, SD 404). Sixty-seven early (≤30 days from implantation) or late complications (>30 days) occurred during the observation period (0.74/1,000 catheter days). Common complications were port infection (0.18/1,000 days), thrombotic dysfunction (0.12/1,000 days), and skin dehiscence (0.12/1,000 days). Nonthrombotic dysfunction occurred in a total of 21 cases (0.23/1,000 days) and seemed to cumulate on the venous catheter entry site on the distal upper arm.ConclusionPeripherally implanted venous access ports in the forearm are a safe alternative to chest or upper-arm ports in female oncology patients. Special attention should be paid to signs of skin dehiscence and nonthrombotic dysfunction, especially when used for long-term treatment.

  17. Exploring the impact of a decision support intervention on vascular access decisions in chronic hemodialysis patients: study protocol

    Directory of Open Access Journals (Sweden)

    Donnelly Sandra

    2011-02-01

    Full Text Available Abstract Background In patients with Stage 5 Chronic Kidney Disease who require renal replacement therapy a major decision concerns modality choice. However, many patients defer the decision about modality choice or they have an urgent or emergent need of RRT, which results in them starting hemodialysis with a Central Venous Catheter. Thereafter, efforts to help patients make more timely decisions about access choices utilizing education and resource allocation strategies met with limited success resulting in a high prevalent CVC use in Canada. Providing decision support tailored to meet patients' decision making needs may improve this situation. The Registered Nurses Association of Ontario has developed a clinical practice guideline to guide decision support for adults living with Chronic Kidney Disease (Decision Support for Adults with Chronic Kidney Disease. The purpose of this study is to determine the impact of implementing selected recommendations this guideline on priority provincial targets for hemodialysis access in patients with Stage 5 CKD who currently use Central Venous Catheters for vascular access. Methods/Design A non-experimental intervention study with repeated measures will be conducted at St. Michaels Hospital in Toronto, Canada. Decisional conflict about dialysis access choice will be measured using the validated SURE tool, an instrument used to identify decisional conflict. Thereafter a tailored decision support intervention will be implemented. Decisional conflict will be re-measured and compared with baseline scores. Patients and staff will be interviewed to gain an understanding of how useful this intervention was for them and whether it would be feasible to implement more widely. Quantitative data will be analyzed using descriptive and inferential statistics. Statistical significance of difference between means over time for aggregated SURE scores (pre/post will be assessed using a paired t-test. Qualitative analysis

  18. Results of a Peripheral Cutting Balloon Prospective Multicenter European Registry in Hemodialysis Vascular Access

    International Nuclear Information System (INIS)

    Peregrin, Jan H.; Rocek, Miloslav

    2007-01-01

    Purpose. To report initial experience with the Peripheral Cutting Balloon (PCB) in treatment of failing hemodialysis shunts. Methods. A total of 190 patients (95 men, 95 women; average age 64.4 ± 11.9 years, range 32-87 years) who were treated with the PCB for pressure-resistant stenosis, restenosis or failed percutaneous transluminal angioplasty (PTA) in the venous limb of an arteriovenous shunt were followed in seven European centers using a simple registry. The group consisted of 109 de novo lesions (57%) and 79 restenotic lesions (43%). Results. Technical success was achieved in 88.9% of cases. Primary patency was as follows (the results for whole group and simultaneous results for de novo lesions and restenoses are presented): 1 month (140 patients followed): 94%, 98%, and 93%; 3 months (116 patients followed): 93%, 98%, and 92%; 6 months (40 patients followed): 85%, 92%, and 79%; 12 months (27 patients followed): 74%, 87%, and 48%. No complication occurred. Patients experienced an equal or lower level of pain during the procedure compared with conventional PTA. Conclusion. The PCB proved to be successful in dilating pressure-resistant stenoses. We cannot conclude whether PCB angioplasty can lower the restenosis rate in hemodialysis access lesions, but the long-term patency for de novo lesions is high. A further randomized study is advisable

  19. Lower limb gigantism, lymphedema, and painful varicosities following a thigh vascular access graft.

    Science.gov (United States)

    Thompson, Michael; Mathuram Thiyagarajan, Umasankar; Akoh, Jacob A

    2014-07-01

    Prosthetic arteriovenous grafts (AVGs) are associated with greater morbidity than autogenous arteriovenous fistulas (AVFs), but their use is indicated when AVF formation is not possible. This report adds to the literature a case of lower limb gigantism, painful varicosities, and lymphedema following long-term use of AVG in the upper thigh. The patient's past medical history included renal transplantation on the same side well before the AVG was inserted and right leg deep vein thrombosis. Suspicion of AVG thrombosis was excluded by Doppler ultrasound, which demonstrated an access flow of 1700 mL/min. A computed tomography (CT) scan of the abdomen and pelvis did not identify the cause of her symptoms. Whereas functional incompetence of the iliac vein valve might be responsible for the varicosities, the extent of hypertrophy in this case raises the suspicion of lymphatic blockage possibly secondary to groin dissection undertaken at the time of graft insertion, in addition to the previous dissection at the time of transplantation. This case highlights the need for minimal groin dissection during AVG insertion, particularly in patients with a history of previous abdominopelvic surgery. © 2014 International Society for Hemodialysis.

  20. Efficiency of the kidney disease outcomes quality initiative guidelines for preemptive vascular access in an academic setting.

    Science.gov (United States)

    Kimball, Traci A; Barz, Ken; Dimond, Kelly R; Edwards, James M; Nehler, Mark R

    2011-09-01

    The National Kidney Foundation-Kidney Diseases Outcomes Quality Initiative (KDOQI) for vascular access guidelines state that patients with late-stage chronic kidney disease (CKD) should undergo native arteriovenous fistula (AVF) creation at least 6 months before anticipated start of hemodialysis (HD) treatments to obviate the need for other vascular access types, such as grafts or central catheters. The objective of this study was to determine the incidence of HD, the functional patency, and associated morbidity of AVFs in patients with late-stage CKD placed according to KDOQI. Consecutive patients with late-stage CKD who underwent AVF creation using KDOQI guidelines for anatomy between January 2003 and December 2007 at two tertiary academic centers were retrospectively evaluated. Baseline demographics, AVF type, and clinical comorbidities were recorded. Patients were stratified into one of four groups (groups A-D) over the follow-up course based on two end points: patency of their AVF and whether or not they began HD. The ideal primary outcome was AVF maturation and use for HD (group A; cumulative functional patency). Other outcomes included AVF patency but no HD (group B), HD with AVF failure (group C), or no HD and AVF abandonment (ie, death, refused hemodialysis, kidney transplant, or fistula failure; group D). Secondary outcomes were time to first cannulation, complications, and secondary interventions. AVFs were created (46% forearm and 54% upper arm) in 150 patients with CKD (85% men, median age 63 years old). At a median follow-up of 10 months, 74 patients (49%) were receiving HD and of these, 48 patients (65%) were using their AVF (group A), whereas 26 patients (35%) were not due to fistula failure (group C). Thirty-four patients (23%) never initiated HD treatments, but had a viable AVF (group B), and 42 patients (28%) never initiated HD and abandoned their AVF (group D). Overall, AVF abandonment was 51%. Mean maturation time of all AVFs successfully

  1. Implantation of venous access devices under local anesthesia: patients’ satisfaction with oral lorazepam

    Directory of Open Access Journals (Sweden)

    Chang DH

    2015-07-01

    Full Text Available De-Hua Chang,1 Sonja Hiss,1 Lena Herich,2 Ingrid Becker,2 Kamal Mammadov,1 Mareike Franke,1 Anastasios Mpotsaris,1 Robert Kleinert,3 Thorsten Persigehl,1 David Maintz,1 Christopher Bangard1 1Department of Radiology, 2Institute of Medical Statistics, Informatics and Epidemiology, 3Department of Surgery, University Hospital of Cologne, Cologne, Germany Objective: The aim of the study reported here was to evaluate patients’ satisfaction with implantation of venous access devices under local anesthesia (LA with and without additional oral sedation.Materials and methods: A total of 77 patients were enrolled in the prospective descriptive study over a period of 6 months. Subcutaneous implantable venous access devices through the subclavian vein were routinely implanted under LA. Patients were offered an additional oral sedative (lorazepam before each procedure. The level of anxiety/tension, the intensity of pain, and patients’ satisfaction were evaluated before and immediately after the procedure using a visual analog scale (ranging from 0 to 10 with a standardized questionnaire.Results: Patients’ satisfaction with the procedure was high (mean: 1.3±2.0 with no significant difference between the group with premedication and the group with LA alone (P=0.54. However, seven out of 30 patients (23.3% in the group that received premedication would not undergo the same procedure without general anesthesia. There was no significant influence of lorazepam on the intensity of pain (P=0.88. In 12 out of 30 patients (40% in the premedication group, the level of tension was higher than 5 on the visual analog scale during the procedure. In 21 out of 77 patients (27.3%, the estimate of the level of tension differed between the interventionist and the patient by 3 or more points in 21 out of 77 patients (27.3%.Conclusion: Overall patient satisfaction is high for implantation of venous access devices under LA. A combination of LA with lorazepam administered

  2. Change in Vascular Access and Hospitalization Risk in Long-Term Hemodialysis Patients

    Science.gov (United States)

    Wang, Weiling; Lazarus, J. Michael; Hakim, Raymond M.

    2010-01-01

    Background and objectives: Conversion from central venous catheters to a graft or a fistula is associated with lower mortality risk in long-term hemodialysis (HD) patients; however, a similar association with hospitalization risk remains to be elucidated. Design, setting, participants, & measurements: We conducted a prospective observational study all maintenance in-center HD patients who were treated in Fresenius Medical Care, North America legacy facilities; were alive on January 1, 2007; and had baseline laboratory data from December 2006. Access conversion (particularly from a catheter to a fistula or a graft) during the 4-month period from January 1 through April 30, 2007, was linked using Cox models to hospitalization risk during the succeeding 1-year follow-up period (until April 30, 2008). Results: The cohort (N = 79,545) on January 1, 2007 had 43% fistulas, 29% catheters, and 27% grafts. By April 30, 2007, 70,852 patients were still on HD, and among 19,792 catheters initially, only 10.3% (2045 patients) converted to either a graft or a fistula. With catheters as reference, patients who converted to grafts/fistulas had similar adjusted hazard ratios (0.69) as patients on fistulas (0.71), while patients with fistulas/grafts who converted to catheters did worse (1.22), all P < 0.0001. Conclusions: Catheters remain associated with the greatest hospitalization risk. Conversion from a catheter to either graft or fistula had significantly lower hospitalization risk relative to keeping the catheter. Prospective studies are needed to determine whether programs that reduce catheters will decrease hospitalization risk in HD patients. PMID:20884778

  3. Pinch-off syndrome: transection of implantable central venous access device.

    Science.gov (United States)

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-11-30

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.

  4. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    Science.gov (United States)

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  5. A comparison of patency and interventions in thigh versus Hemodialysis Reliable Outflow grafts for chronic hemodialysis vascular access.

    Science.gov (United States)

    Brownie, Evan R; Kensinger, Clark D; Feurer, Irene D; Moore, Derek E; Shaffer, David

    2016-11-01

    With improvements in medical management and survival of patients with end-stage renal disease, maintaining durable vascular access is increasingly challenging. This study compared primary, assisted primary, and secondary patency, and procedure-specific complications, and evaluated whether the number of interventions to maintain or restore patency differed between prosthetic femoral-femoral looped inguinal access (thigh) grafts and Hemodialysis Reliable Outflow (HeRO; Hemosphere Inc, Minneapolis, Minn) grafts. A single-center, retrospective, intention-to-treat analysis was conducted of consecutive thigh and HeRO grafts placed between May 2004 and June 2015. Medical history, interventions to maintain or restore patency, and complications were abstracted from the electronic medical record. Data were analyzed using parametric and nonparametric statistical tests, Kaplan-Meier survival methods, and multivariable proportional hazards regression and logistic regression. Seventy-six (43 thigh, 33 HeRO) grafts were placed in 61 patients (54% male; age 53 [standard deviation, 13] years). Median follow-up time in the intention-to-treat analysis was 21.2 months (min, 0.0; max, 85.3 months) for thigh grafts and 6.7 months (min, 0.0; max, 56.3 months) for HeRO grafts (P = .02). The groups were comparable for sex, age, coronary artery disease, diabetes mellitus, peripheral vascular disease, and smoking history (all P ≥ .12). One thigh graft (2%) and five HeRO (15%) grafts failed primarily. In the intention-to-treat analysis, patency durations were significantly longer in the thigh grafts (all log-rank P ≤ .01). Point estimates of primary patency at 6 months, 1 year, and 3 years were 61%, 46%, and 4% for the thigh grafts and 25%, 15%, and 6% for the HeRO grafts. Point estimates of assisted primary patency at 6 months, 1 year, and 3 years were 75%, 66%, and 54% for the thigh grafts and 41%, 30%, and 10% for the HeRO grafts. Point estimates of secondary patency at 6

  6. HACMAC: A reliable human activity-based medium access control for implantable body sensor networks

    NARCIS (Netherlands)

    Karuppiah Ramachandran, Vignesh Raja; Havinga, Paul J.M.; Meratnia, Nirvana

    Chronic care is an eminent application of implantable body sensor networks (IBSN). Performing physical activities such as walking, running, and sitting is unavoidable during the long-term monitoring of chronic-care patients. These physical activities cripple the radio frequency (RF) signal between

  7. Angiotensin Converting-Enzyme Inhibitors, Angiotensin Receptor Blockers, and Calcium Channel Blockers Are Associated with Prolonged Vascular Access Patency in Uremic Patients Undergoing Hemodialysis.

    Directory of Open Access Journals (Sweden)

    Fu-An Chen

    Full Text Available Vascular access failure is a huge burden for patients undergoing hemodialysis. Many efforts have been made to maintain vascular access patency, including pharmacotherapy. Angiotensin converting enzyme inhibitor (ACE-I, angiotensin receptor blocker (ARB, and calcium channel blocker (CCB are known for their antihypertensive and cardio-protective effects, however, their effects on long-term vascular access patency are still inconclusive.We retrospectively enrolled patients commencing maintenance hemodialysis between January 1, 2000, and December 31, 2006 by using National Health Insurance Research Database in Taiwan. Primary patency was defined as the date of first arteriovenous fistula (AVF or arteriovenous graft (AVG creation to the time of access thrombosis or any intervention aimed to maintain or re-establish vascular access patency. Cox proportional hazards models were used to adjust the influences of patient characteristics, co-morbidities and medications.Total 42244 patients were enrolled in this study, 37771 (89.4% used AVF, 4473 (10.6% used AVG as their first long term dialysis access. ACE-I, ARB, and CCB use were all associated with prolonged primary patency of AVF [hazard ratio (HR 0.586, 95% confidence interval (CI 0.557-0.616 for ACE-I use; HR 0.532, CI 0.508-0.556 for ARB use; HR 0.485, CI 0.470-0.501 for CCB use] and AVG (HR 0.557, CI 0.482-0.643 for ACE-I use, HR 0.536, CI 0.467-0.614 for ARB use, HR 0.482, CI 0.442-0.526 for CCB use.In our analysis, ACE-I, ARB, and CCB were strongly associated with prolonged primary patency of both AVF and AVG. Further prospective randomized studies are still warranted to prove the causality.

  8. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  9. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    El-Mawardy, Mohamed; Schwarz, Bettina; Landt, Martin; Sulimov, Dmitriy; Kebernik, Julia; Allali, Abdelhakim; Becker, Bjoern; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-01-20

    The use of large-diameter sheaths carries the risk of significant vascular and bleeding complications after transfemoral transcatheter aortic valve implantation (TAVI). In this analysis, we sought to assess the impact of a modified femoral artery puncture technique using digital subtraction angiography (DSA) and road mapping during transfemoral TAVI on periprocedural vascular and bleeding events. This is a retrospective analysis of transfemoral TAVI patients included in a prospective institutional database. The modified femoral artery puncture technique using DSA-derived road mapping guidance was introduced in October 2012. Before the introduction of this technique, vascular puncture was acquired based on an integration of angiographic data, the bony iliofemoral landmarks and a radiopaque object. Consecutive patients who underwent TAVI with the road mapping technique (RM group, n=160) were compared with consecutive patients who underwent TAVI without road mapping (control group, n=160) prior to its introduction. A standardised strategy of periprocedural anticoagulation was adopted in both groups as well as the use of a single suture-based closure device. All endpoints were defined according to the VARC-2 criteria for event definition. The mean age in the RM group was 80±7.7 years compared to 81±5.9 years in the control group (p=0.19), and females were equally distributed between both groups (63.1% vs. 58.1%, p=0.36). The baseline logistic EuroSCORE was 20.7±14.4% vs. 24.9±15.2% in the RM and control group, respectively (p=0.01). Notably, sheath size was significantly larger in the RM compared to the control group due to the more frequent use of the 20 Fr sheath (23.8% vs. 1.8%, proad map group but did not reach statistical significance (8.1% vs. 13.8%, p=0.1). Other forms of vascular and bleeding complications as well as all-cause mortality were comparable in both groups. A modified femoral artery puncture technique using DSA and road mapping was associated

  10. [Initial experiences with a new painless vascular approach in hemodialysis in children].

    Science.gov (United States)

    Klare, B; Kemkes, B M

    1982-09-09

    The necessity of hemodialysis in children is pointed out to be treated at specialized pediatric dialysis centers. In this connection a new vascular access is presented. The device is made from vitreous carbon and is mounted on a PTFE vascular prosthesis. By means of disposable connectors it can be dialysed without puncturing the implant. The device was implanted for the first time in the world in a small boy of 19 kg bodyweight. Our conclusion is that the biocarbon device is a welcome alleviation and an alternative for angio-access in children.

  11. An evaluation of the availability, accessibility, and quality of online content of vascular surgery training program websites for residency and fellowship applicants.

    Science.gov (United States)

    Huang, Bryant Y; Hicks, Taylor D; Haidar, Georges M; Pounds, Lori L; Davies, Mark G

    2017-12-01

    Vascular surgery residency and fellowship applicants commonly seek information about programs from the Internet. Lack of an effective web presence curtails the ability of programs to attract applicants, and in turn applicants may be unable to ascertain which programs are the best fit for their career aspirations. This study was designed to evaluate the presence, accessibility, comprehensiveness, and quality of vascular surgery training websites (VSTW). A list of accredited vascular surgery training programs (integrated residencies and fellowships) was obtained from four databases for vascular surgery education: the Accreditation Council for Graduate Medical Education, Electronic Residency Application Service, Fellowship and Residency Electronic Interactive Database, and Society for Vascular Surgery. Programs participating in the 2016 National Resident Matching Program were eligible for study inclusion. Accessibility of VSTW was determined by surveying the Accreditation Council for Graduate Medical Education, Electronic Residency Application Service, and Fellowship and Residency Electronic Interactive Database for the total number of programs listed and for the presence or absence of website links. VSTW were analyzed for the availability of recruitment and education content items. The quality of VSTW was determined as a composite of four dimensions: content, design, organization, and user friendliness. Percent agreements and kappa statistics were calculated for inter-rater reliability. Eighty-nine of the 94 fellowship (95%) and 45 of the 48 integrated residencies (94%) programs participating in the 2016 Match had a VSTW. For program recruitment, evaluators found an average of 12 of 32 content items (35.0%) for fellowship programs and an average of 12 of 32 (37%) for integrated residencies. Only 47.1% of fellowship programs (53% integrated residencies) specified the number of positions available for the 2016 Match, 20% (13% integrated residencies) indicated alumni

  12. Vascular Access Procedures

    Science.gov (United States)

    ... the catheter. top of page What are the benefits vs. risks? Benefits A central catheter permits infusion of solutions containing ... products may be given by this route, including antibiotics and blood products. The catheter also may be ...

  13. The benefit of non contrast-enhanced magnetic resonance angiography for predicting vascular access surgery outcome: a computer model perspective.

    Directory of Open Access Journals (Sweden)

    Maarten A G Merkx

    Full Text Available INTRODUCTION: Vascular access (VA surgery, a prerequisite for hemodialysis treatment of end-stage renal-disease (ESRD patients, is hampered by complication rates, which are frequently related to flow enhancement. To assist in VA surgery planning, a patient-specific computer model for postoperative flow enhancement was developed. The purpose of this study is to assess the benefit of non contrast-enhanced magnetic resonance angiography (NCE-MRA data as patient-specific geometrical input for the model-based prediction of surgery outcome. METHODS: 25 ESRD patients were included in this study. All patients received a NCE-MRA examination of the upper extremity blood vessels in addition to routine ultrasound (US. Local arterial radii were assessed from NCE-MRA and converted to model input using a linear fit per artery. Venous radii were determined with US. The effect of radius measurement uncertainty on model predictions was accounted for by performing Monte-Carlo simulations. The resulting flow prediction interval of the computer model was compared with the postoperative flow obtained from US. Patients with no overlap between model-based prediction and postoperative measurement were further analyzed to determine whether an increase in geometrical detail improved computer model prediction. RESULTS: Overlap between postoperative flows and model-based predictions was obtained for 71% of patients. Detailed inspection of non-overlapping cases revealed that the geometrical details that could be assessed from NCE-MRA explained most of the differences, and moreover, upon addition of these details in the computer model the flow predictions improved. CONCLUSIONS: The results demonstrate clearly that NCE-MRA does provide valuable geometrical information for VA surgery planning. Therefore, it is recommended to use this modality, at least for patients at risk for local or global narrowing of the blood vessels as well as for patients for whom an US-based model

  14. Procedures can be learned on the Web: a randomized study of ultrasound-guided vascular access training.

    Science.gov (United States)

    Chenkin, Jordan; Lee, Shirley; Huynh, Thien; Bandiera, Glen

    2008-10-01

    Web-based learning has several potential advantages over lectures, such as anytime-anywhere access, rich multimedia, and nonlinear navigation. While known to be an effective method for learning facts, few studies have examined the effectiveness of Web-based formats for learning procedural skills. The authors sought to determine whether a Web-based tutorial is at least as effective as a didactic lecture for learning ultrasound-guided vascular access (UGVA). Participating staff emergency physicians (EPs) and junior emergency medicine (EM) residents with no UGVA experience completed a precourse test and were randomized to either a Web-based or a didactic group. The Web-based group was instructed to use an online tutorial and the didactic group attended a lecture. Participants then practiced on simulators and live models without any further instruction. Following a rest period, participants completed a four-station objective structured clinical examination (OSCE), a written examination, and a postcourse questionnaire. Examination results were compared using a noninferiority data analysis with a 10% margin of difference. Twenty-one residents and EPs participated in the study. There were no significant differences in mean OSCE scores (absolute difference = -2.8%; 95% confidence interval [CI] = -9.3% to 3.8%) or written test scores (absolute difference = -1.4%; 95% CI = -7.8% to 5.0%) between the Web group and the didactic group. Both groups demonstrated similar improvements in written test scores (26.1% vs. 25.8%; p = 0.95). Ninety-one percent (10/11) of the Web group and 80% (8/10) of the didactic group participants found the teaching format to be effective (p = 0.59). Our Web-based tutorial was at least as effective as a traditional didactic lecture for teaching the knowledge and skills essential for UGVA. Participants expressed high satisfaction with this teaching technology. Web-based teaching may be a useful alternative to didactic teaching for learning procedural

  15. Metastatic spread from squamous cell carcinoma of the hypopharynx to the totally implantable venous access port insertion site: Case report and review of literature.

    Science.gov (United States)

    Mangla, Ankit; Agarwal, Nikki; Mullane, Michael Russell

    2017-12-01

    The totally implantable venous access port plays a crucial role in delivering chemotherapy in the outpatient setting. Here, we report the first case of a patient with hypopharyngeal tumor who developed chest wall metastasis over the totally implantable venous access port inserted in the internal jugular vein. Our patient, a 58-year-old man with a hypopharyngeal tumor presented with a lump over the totally implantable venous access port site. The port was removed and the lump was biopsied. The CT studies showed that the tumor had spread along the catheter from the hypopharynx to the chest wall. The pathology from the biopsy showed squamous cell carcinoma (SCC). The patient had poor performance status and opted for hospice care. We present a novel case of metastasis over the totally implantable venous access port implanted in a patient with a hypopharyngeal tumor. We also reviewed relevant literature comparing the data from percutaneous endoscopic gastrostomy (PEG) tube site metastasis with our patient and other similar case reports. © 2017 Wiley Periodicals, Inc.

  16. Motivo de "escolha" de diálise peritoneal: exaustão de acesso vascular para hemodiálise? Reason for "choosing" peritoneal dialysis: exhaustion of vascular access for hemodialysis?

    Directory of Open Access Journals (Sweden)

    Paulo Novis Rocha

    2010-03-01

    Full Text Available INTRODUÇÃO: Pouco se conhece sobre a evolução de pacientes que iniciam DP como única alternativa. OBJETIVOS: Descrever o perfil clínico-demográfico e a ocorrência de peritonite em uma amostra de pacientes convertidos de HD para DP por exaustão de acesso vascular. MÉTODOS: Revisão dos prontuários de todos os pacientes do programa de DP do HGRS. RESULTADOS: Foram estudados 22 pacientes com idade mediana de 47,9 anos, 54,5% de homens, 84,2% de negros ou mulatos, 68,2% procedentes do interior da Bahia. DP foi a modalidade inicial de TRS em apenas quatro pacientes. Os 18 pacientes restantes iniciaram TRS através de HD; neste grupo, predominou o início de HD de forma emergencial e através de cateter duplo-lúmen (CDL. Em uma mediana de 7,7 meses em HD, a maioria dos pacientes (64,7% usou mais de quatro CDL. Em apenas 7/18 (39% pacientes, a conversão de HD para DP foi feita por escolha do paciente; na maioria dos casos, 11/18 (61%, o motivo de conversão foi exaustão de acesso vascular para HD. Peritonite foi mais frequente nos pacientes que entraram em HD por exaustão de acesso vascular que no restante do grupo. CONCLUSÕES: O início de TRS de forma emergencial através de HD utilizando CDL pode levar a uma rápida exaustão de acesso vascular, deixando a DP como única alternativa viável. Este modo inadequado de "seleção" de pacientes para DP está associado a maiores chances de ocorrência de peritonite.INTRODUCTION: Little is known about the prognosis of patients beginnig peritoneal dialysis (PD as their last alternative. OBJECTIVES: To describe the clinical-demographic profile of patients switching from hemodialysis (HD to PD, due to exhaustion of the HD vascular access, and the occurrence of peritonitis among them. METHODS: Review of the medical records of all patients in the PD program of the Hospital Roberto Santos in the city of Salvador, state of Bahia, Brazil. RESULTS: The study comprised 22 patients (median age, 47

  17. Patients undergoing PCI from the femoral route by default radial operators are at high risk of vascular access-site complications.

    Science.gov (United States)

    Rafie, Ihsan M; Uddin, Muez M; Ossei-Gerning, Nicholas; Anderson, Richard A; Kinnaird, Timothy D

    2014-02-01

    Radial artery (RA) access for PCI has a lower incidence of vascular access-site (VAS) complications than the femoral artery (FA) approach. However, even for default radial operators certain patients are intervened upon from the FA. We examined the demographics and incidence of VAS complications when default radial operators resort to the FA for PCI. The demographics and VAS complications were compared by access site retrospectively for all PCI cases performed by default radial operators (n=1,392). A modified ACUITY trial definition of major VAS complication was used. FA puncture occurred in 25.2% (351/1,392) of cases. Patients were more likely to be female, older and weigh less than patients undergoing PCI from the RA. The FA procedure was likely to be more complex with larger sheaths, more left main stem, graft and multivessel intervention, and there was a greater proportion of emergency cases. Despite increased case complexity, glycoprotein inhibitors were used less frequently in femoral cases (26.5% vs. 36.8%, prisk factors for access-site bleeding are disproportionately high in the population requiring FA puncture by default radial operators, and as a result such patients have a high rate of vascular access-site complications.

  18. Neurofeedback Control in Parkinsonian Patients Using Electrocorticography Signals Accessed Wirelessly With a Chronic, Fully Implanted Device.

    Science.gov (United States)

    Khanna, Preeya; Swann, Nicole C; de Hemptinne, Coralie; Miocinovic, Svjetlana; Miller, Andrew; Starr, Philip A; Carmena, Jose M

    2017-10-01

    Parkinson's disease (PD) is characterized by motor symptoms such as rigidity and bradykinesia that prevent normal movement. Beta band oscillations (13-30 Hz) in neural local field potentials (LFPs) have been associated with these motor symptoms. Here, three PD patients implanted with a therapeutic deep brain neural stimulator that can also record and wirelessly stream neural data played a neurofeedback game where they modulated their beta band power from sensorimotor cortical areas. Patients' beta band power was streamed in real-time to update the position of a cursor that they tried to drive into a cued target. After playing the game for 1-2 hours each, all three patients exhibited above chance-level performance regardless of subcortical stimulation levels. This study, for the first time, demonstrates using an invasive neural recording system for at-home neurofeedback training. Future work will investigate chronic neurofeedback training as a potentially therapeutic tool for patients with neurological disorders.

  19. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats Efeitos da nitroglicerina tópica na autonomização de retalhos pré-fabricados por implante vascular em ratos

    Directory of Open Access Journals (Sweden)

    Jairo Zacchê de Sá

    2012-12-01

    Full Text Available PURPOSE: To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. METHODS: A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. RESULTS: The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005, 1 and 4 (p=0.024, 2 and 3 (p=0.003, 2 and 4 (p=0.001. These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. CONCLUSION: Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.OBJETIVO: Avaliar o efeito da nitroglicerina tópica sobre a área viável de um modelo de retalho pré-fabricado por implante vascular em ratos e analisar o mecanismo de autonomização cirúrgica aplicada a retalhos pré-fabricados. MÉTODOS: Foram utilizados 40 ratos Wistar. No primeiro tempo cirúrgico - 20 ratos foram submetidos a implante do pedículo femoral na região subdérmica da parede abdominal, e 20 submetidos à autonomização cirúrgica de retalho cutâneo de parede abdominal e, simultaneamente, implante do pedículo femoral na região subdérmica deste retalho. No segundo tempo - após três semanas e em todos os animais

  20. Association of vascular access flow with short-term and long-term mortality in chronic haemodialysis patients: a retrospective cohort study.

    Science.gov (United States)

    Wu, Chung-Kuan; Wu, Chia-Lin; Lin, Chia-Hsun; Leu, Jyh-Gang; Kor, Chew-Teng; Tarng, Der-Cherng

    2017-09-24

    To investigate the impact of vascular access flow (Qa) on vascular and all-cause mortality in chronic haemodialysis (HD) patients. Observational cohort study. Single centre. Adult chronic HD patients at the HD unit of Shin Kong Wu Ho-Su Memorial Hospital between 1 January 2003 and 31 December 2003 were recruited. Patients were excluded if they had arteriovenous fistula or arteriovenous graft failure within 3 months before the date of Qa measurement, were aged Short-term and long-term vascular (cardiovascular or cerebrovascular) and all-cause mortality. Qa was positively correlated with CI ( r =0.48, plong-term all-cause mortality (adjusted HR, 1.62; 95% CI 1.11 to 2.37; p=0.013); however, the risk of vascular mortality did not significantly increase after adjustment for confounders. Qa is moderately correlated with cardiac function, and a Qa level of short-term and long-term all-cause mortality in chronic HD patients. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

    Directory of Open Access Journals (Sweden)

    Hadi Mokhtarpour

    2016-07-01

    Full Text Available Background. Fracture load of implant-supported restorations is an important factor in clinical success. This study evaluated the effect of two techniques for screw access hole preparation on the fracture load of cement-screw-retained implant-supported zirconia-based crowns. Methods. Thirty similar cement-screw-retained implant-supported zirconia-based maxillary central incisor crowns were evaluated in three groups of 10. Group NH: with no screw access holes for the control; Group HBS: with screw access holes prepared with a machine before zirconia sintering; Group HAS: with screw access holes prepared manually after zirconia sintering. In group HBS, the access holes were virtually designed and prepared by a computer-assisted design/computer-assisted manufacturing system. In group HAS, the access holes were manually prepared after zirconia sintering using a diamond bur. The dimensions of the screw access holes were equal in both groups. The crowns were cemented onto same-size abutments and were then subjected to thermocycling. The fracture load values of the crowns were measured using a universal testing machine. Data were analyzed with ANOVA and Tukey test (P < 0.05. Results. The mean fracture load value for the group NH was 888.37 ± 228.92 N, which was the highest among the groups, with a significant difference (P < 0.0001. The fracture load values were 610.48 ± 125.02 N and 496.74 ± 104.10 Nin the HBS and HAS groups, respectively, with no significant differences (P = 0.44. Conclusion. Both techniques used for preparation of screw access holes in implant-supported zirconia-based crowns de-creased the fracture load.

  2. Intracoronary stent implantation: new approach using a monorail system and new large-lumen 7F catheters from the brachial route.

    Science.gov (United States)

    Jenny, D B; Robert, G P; Fajadet, J C; Cassagneau, B G; Marco, J

    1992-04-01

    In this brief report we describe a case of successful multivessel PTCA with intracoronary stent implantation using a new large-lumen 7F catheter from the left brachial approach. The application of this technique should be considered for intravascular stent implantation when anticoagulation ideally should not be interrupted or in anatomical situations limiting femoral vascular access.

  3. Nova técnica para treinamento em acessos vasculares guiados por ultrassom utilizando modelo de tecido animal New technique for ultrasound-guided vascular access training using an animal tissue model

    Directory of Open Access Journals (Sweden)

    Robson Barbosa de Miranda

    2012-03-01

    Full Text Available A ultrassonografia Doppler deixou de ter seu uso apenas como método diagnóstico e vem galgando espaço nos procedimentos terapêuticos. Com maior aplicabilidade e uso de cateteres venosos centrais e procedimentos guiados por ultrassom, há preocupação com a melhora da eficácia e segurança durante o procedimento, assim como com a diminuição das potenciais complicações. Para isso, o treinamento da técnica em modelos (phantoms é desejável. Os modelos industrializados para treinamento em acesso vascular guiado por ultrassom são caros e não reproduzem adequadamente a ecotextura e a densidade dos tecidos humanos. Na tentativa de treinar e aprimorar os profissionais para o uso do ultrassom em procedimentos de acessos vasculares, desenvolveu-se um modelo animal de baixo custo, fácil confecção e excelente aplicabilidade.Duplex ultrasonography has not been used only as a noninvasive diagnostic method. Recently it has been applied for therapeutic procedures. Due to the increasing use and applicability of central venous catheters and eco-guided vascular procedures, there are concerns about improving results regarding accuracy and safety, reducing complication rates during those procedures. It would be desirable that training was accomplished using phantoms before actual procedures in human subjects. Industrialized phantoms are expensive and they do not reproduce human's ecographic density and texture. In order to train and improve ultrasound guided vascular access, we have developed a cheap animal tissue model, which is of easy preparation and applicability.

  4. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  5. Lexical-Access Ability and Cognitive Predictors of Speech Recognition in Noise in Adult Cochlear Implant Users.

    Science.gov (United States)

    Kaandorp, Marre W; Smits, Cas; Merkus, Paul; Festen, Joost M; Goverts, S Theo

    2017-01-01

    Not all of the variance in speech-recognition performance of cochlear implant (CI) users can be explained by biographic and auditory factors. In normal-hearing listeners, linguistic and cognitive factors determine most of speech-in-noise performance. The current study explored specifically the influence of visually measured lexical-access ability compared with other cognitive factors on speech recognition of 24 postlingually deafened CI users. Speech-recognition performance was measured with monosyllables in quiet (consonant-vowel-consonant [CVC]), sentences-in-noise (SIN), and digit-triplets in noise (DIN). In addition to a composite variable of lexical-access ability (LA), measured with a lexical-decision test (LDT) and word-naming task, vocabulary size, working-memory capacity (Reading Span test [RSpan]), and a visual analogue of the SIN test (text reception threshold test) were measured. The DIN test was used to correct for auditory factors in SIN thresholds by taking the difference between SIN and DIN: SRT diff . Correlation analyses revealed that duration of hearing loss (dHL) was related to SIN thresholds. Better working-memory capacity was related to SIN and SRT diff scores. LDT reaction time was positively correlated with SRT diff scores. No significant relationships were found for CVC or DIN scores with the predictor variables. Regression analyses showed that together with dHL, RSpan explained 55% of the variance in SIN thresholds. When controlling for auditory performance, LA, LDT, and RSpan separately explained, together with dHL, respectively 37%, 36%, and 46% of the variance in SRT diff outcome. The results suggest that poor verbal working-memory capacity and to a lesser extent poor lexical-access ability limit speech-recognition ability in listeners with a CI.

  6. Vascular access strategy for delivering long-term antimicrobials to patients with infective endocarditis: device type, risk of infection and mortality.

    Science.gov (United States)

    Ahmed, F Z; Baig, W W; Munyombwe, T; West, R; Sandoe, J A T

    2013-01-01

    This paper reports the use of different vascular access devices and the incidence of intravascular catheter-related infection (CRI) in patients receiving intravenous antibiotics for infective endocarditis (IE). To examine whether rates of infection vary with type of vascular access device, and assess the impact of CRI on mortality in IE. A prospective observational service evaluation of all inpatients who received intravenous antibiotics for IE was performed. In total, 114 inpatients were evaluated. All cases of CRI [including exit-site infection, intravascular catheter-related bloodstream infection (CRBSI) and mortality] were recorded. Tunnelled and non-tunnelled central venous catheters (CVCs), and peripherally inserted cannulae were used for antibiotic delivery. There were 15 episodes of CRI, 11 of which were CRBSI (all associated with CVC use). The remainder comprised uncomplicated exit-site infections. Use of tunnelled CVCs [hazard ratio (HR) 16.95, 95% confidence interval (CI) 2.13-134.93; P = 0.007] and non-tunnelled CVCs (HR 24.54, 95% CI 2.83-212.55; P = 0.004) was associated with a significantly increased risk of CRI. Risk of mortality increased significantly with Staphylococcus aureus as the cause of IE (P < 0.001) and CRBSI (P = 0.034). Risk of CRI in patients with IE is linked to the type of vascular access device used. Rates of CRBSI were greatest with CVCs, while peripheral venous cannulae were not associated with CRBSI or serious sequelae. Many patients (40%) tolerated complete treatment courses delivered via peripheral cannulae. These findings confirm the importance of device selection in reducing the risk of CRI; a potentially modifiable variable that impacts on outcome and mortality in IE. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  8. Totally implantable central venous access port infections in patients with digestive cancer: incidence and risk factors.

    Science.gov (United States)

    Touré, Abdoulaye; Vanhems, Philippe; Lombard-Bohas, Catherine; Cassier, Philippe; Péré-Vergé, Denis; Souquet, Jean-Christophe; Ecochard, René; Chambrier, Cécile

    2012-12-01

    Central venous access port-related bloodstream infection (CVAP-BSI) is associated with morbidity and mortality in patients with cancer. This study examined the incidence rates and risk factors for CVAP-BSI in adult patients with digestive cancer. This prospective observational cohort study was performed from 2007 to 2011 in 2 oncology units of a university hospital. Incidence rate was expressed as number of CVAP-BSI per 1,000 catheter-days. A Cox regression model was used to identify risk factors for CVAP-BSI. A total of 315 patients were included. CVAP-BSI occurred in 41 patients (13.0%). The overall incidence rate was 0.76/1,000 catheter-days. The rate was higher in patients with esophageal cancer (1.28. P = .05) and pancreatic cancer (1.24; P = .007). Risk factors independently associated with CVAP-BSI were World Health Organization performance status between 2 and 4, catheter utilization-days in the previous month, pancreatic cancer, and parenteral nutrition. Coagulase-negative Staphylococci and enterobacteria were the main microorganisms isolated. In adult patients with digestive cancer, pancreatic cancer, cumulative catheter utilization-days, World Health Organization performance status, and parenteral nutrition were identified as independent risk factors for CVAP-BSI. Patients with any of these risk factors could be candidates for preventive strategies. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].

    Science.gov (United States)

    Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S

    2015-01-01

    Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  10. Virtual-Reality Simulator System for Double Interventional Cardiac Catheterization Using Fractional-Order Vascular Access Tracker and Haptic Force Producer

    Directory of Open Access Journals (Sweden)

    Guan-Chun Chen

    2015-01-01

    Full Text Available This study proposes virtual-reality (VR simulator system for double interventional cardiac catheterization (ICC using fractional-order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double-catheter mechanism is designed for the ICC procedures. A fractional-order vascular access tracker is used to trace the senior surgeons’ consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs. The VR establishment with surgeons’ consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures.

  11. Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: Retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Mei Jul; Liang, Huei Lung; Pan, Huay Ben [Dept. of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung (China); Chen, Matt Chiung Yu [Dept. of Radiology, Yuan' s General Hospital, Kaohsiung (China)

    2013-01-15

    The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post

  12. Access to Posthospitalization Acute Care Facilities is Associated with Payer Status for Open Abdominal Aortic Repair and Open Lower Extremity Revascularization in the Vascular Quality Initiative.

    Science.gov (United States)

    Ulloa, Jesus G; Woo, Karen; Tseng, Chi-Hong; Maggard-Gibbons, Melinda; Rigberg, David

    2017-07-01

    Uninsured patients may not have access to postacute care facilities that play an important role in clinical recovery, and functional outcomes after vascular surgery. We sought to determine whether discharge disposition is associated with insurance status. We retrospectively reviewed data from the Vascular Quality Initiative ® for patients who underwent open abdominal aortic repair, infrainguinal bypass, or suprainguinal bypass (SB) between January 2012 and July 2015. Mixed-effects logistic regression analysis with clustering at the surgeon and facility level was used to calculate 95% confidence intervals for discharge disposition to home, skilled nursing facility (SNF) or rehabilitation (Rehab) facility by payer status (Medicare, Medicaid, Commercial, Military/Veterans Affairs, Non-US Insurance, or Self-pay), with adjustment for patient, operative, and postoperative characteristics. The study cohort comprised 18,478 procedures (open abdominal aortic repair = 2,817; infrainguinal bypass = 11,572; suprainguinal bypass = 4,089) after we excluded procedures with missing data and in-hospital deaths. Twenty-four percent of the cohort was discharged to an SNF or Rehab site. On univariate analysis, the odds ratio (OR) of discharge home was 4.38 (95% CI: 3.33-5.77) for self-pay as compared to Medicare. On mixed-effects analysis, the adjusted odds of discharge home for self-pay as compared to Medicare remained high (OR = 3.09; 95% CI: 2.23-4.26), after adjustment for age, gender, race/ethnicity, preoperative ambulatory status, number of comorbidities, case urgency, total operative time, presence of a postoperative complication, procedure type, and length of stay. Adjusted odds for discharge to SNF (OR = 0.26; 95% CI: 0.15-0.46) and Rehab (OR = 0.50; 95% CI: 0.35-0.72) were lowest for self-pay status. Access to postacute care facilities is associated with insurance status. Self-pay (uninsured) patients are less likely to have access to discharge services that may

  13. Accessibility

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2017-01-01

    This contribution is timely as it addresses accessibility in regards system hardware and software aligned with introduction of the Twenty-First Century Communications and Video Accessibility Act (CVAA) and adjoined game industry waiver that comes into force January 2017. This is an act created...... by the USA Federal Communications Commission (FCC) to increase the access of persons with disabilities to modern communications, and for other purposes. The act impacts advanced communications services and products including text messaging; e-mail; instant messaging; video communications; browsers; game...... platforms; and games software. However, the CVAA has no legal status in the EU. This text succinctly introduces and questions implications, impact, and wider adoption. By presenting the full CVAA and game industry waiver the text targets to motivate discussions and further publications on the subject...

  14. Evaluation of the psychometric properties of the phlebitis and infiltration scales for the assessment of complications of peripheral vascular access devices.

    Science.gov (United States)

    Groll, Dianne; Davies, Barbara; Mac Donald, Joan; Nelson, Susanne; Virani, Tazim

    2010-01-01

    To prevent complications from peripheral vascular access device (PVAD) therapy, the Infusion Nurses Society (INS) developed 2 scales to measure the extent and severity of phlebitis and infiltration in PVADs. This study evaluated the psychometric properties of these scales to validate them with respect to their interrater reliability, concurrent validity, feasibility, and acceptability. A total of 182 patients at 2 sites were enrolled, and 416 observations of PVAD sites were made. Two nurses independently rated each PVAD site for the presence or absence of phlebitis and/or infiltration by using the INS scales. The interrater reliability was calculated, as was the agreement of the observed versus charted incidence of phlebitis and infiltration (concurrent validity) and the ease of use of the scales (feasibility, acceptability). Interrater reliability for both the Phlebitis and Infiltration scales and concurrent validity were found to be statistically significant (P Phlebitis and Infiltration scales have been shown to be easy to use, valid, and reliable scales.

  15. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

    Directory of Open Access Journals (Sweden)

    Rolf Bambauer

    2012-01-01

    Full Text Available Background. Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels. Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications. Methods. This retrospective study (1992–2007 evaluated silver-coated (54 patients and noncoated (105 patients implanted large-bore catheters used for extracorporeal detoxification. The catheters were inserted into the internal jugular or subclavian veins. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using scanning electron microscope. Results. The silver coated catheters showed a tendency towards longer in situ time. The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant. Conclusion. The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study. There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort. Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

  16. Effect of modifying the screw access channels of zirconia implant abutment on the cement flow pattern and retention of zirconia restorations.

    Science.gov (United States)

    Wadhwani, Chandur; Chung, Kwok-Hung

    2014-07-01

    The effect of managing the screw access channels of zirconia implant abutments in the esthetic zone has not been extensively evaluated. The purpose of this study was to determine the effect of an insert placed within the screw access channel of an anterior zirconia implant abutment on the amount of cement retained within the restoration-abutment system and on the dislodging force. Thirty-six paired zirconia abutments and restorations were fabricated by computer-aided design and computer-aided manufacturing and were divided into 3 groups: open abutment, with the screw access channel unfilled; closed abutment, with the screw access channel sealed; and insert abutment, with a thin, tubular metal insert projection continuous with the screw head and placed into the abutment screw access channel. The restorations were cemented to the abutments with preweighed eugenol-free zinc oxide cement (TempBond NE). Excess cement was removed, and the weight of the cement that remained in the restoration-abutment system was measured. Vertical tensile dislodging forces were recorded at a crosshead speed of 5 mm/min after incubation in a 37°C water bath for 24 hours. The specimens were examined for the cement flow pattern into the screw access channel after dislodgement. Data were analyzed with ANOVA, followed by multiple comparisons by using the Tukey honestly significant difference test (α = .05). The mean (standard deviation) of retentive force values ranged from 108.1 ± 29.9 N to 148.3 ± 21.0 N. The retentive force values differed significantly between the insert abutment and both the open abutment (P abutment groups (P abutment and insert abutment being greater than closed abutment (P abutment with a metal insert significantly affected both the cement retained within the abutment itself and the retention capabilities of the zirconia restoration cemented with TempBond NE cement. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier

  17. Amplatzer vascular plugs in congenital cardiovascular malformations

    International Nuclear Information System (INIS)

    Barwad, Parag; Ramakrishnan, Sivasubramanian; Kothari, Shyam S; Saxena, Anita; Gupta, Saurabh K; Juneja, Rajnish; Gulati, Gurpreet Singh; Jagia, Priya; Sharma, Sanjiv

    2013-01-01

    Amplatzer vascular plugs (AVPs) are devices ideally suited to close medium-to-large vascular communications. There is limited published literature regarding the utility of AVPs in congenital cardiovascular malformations (CCVMs). To describe the use of AVPs in different CCVMs and to evaluate their safety and efficacy. All patients who required an AVP for the closure of CCVM were included in this retrospective review of our catheterization laboratory data. The efficacy and safety of AVPs are reported. A total of 39 AVPs were implanted in 31 patients. Thirteen (33%) were AVP type I and 23 (59%) were AVP type II. AVP type III were implanted in two patients and type IV in one patient. The major indications for their use included closure of pulmonary arteriovenous malformation (AVM) (n = 7), aortopulmonary collaterals (n = 7), closure of a patent Blalock-Taussig shunt (n = 5), systemic AVM (n = 5), coronary AVM (n = 4), patent ductus arteriosus (PDA) (n = 3), pulmonary artery aneurysms (n = 3), and venovenous collaterals (n = 2). Deployment of the AVP was done predominantly via the 5 – 7F Judkin's right coronary guide catheter. Overall 92% of the AVPs could be successfully deployed and resulted in occlusion of the target vessel in all cases, within 10 minutes. No procedure-related or access site complication occurred. AVPs are versatile, easy to use, and effective devices to occlude the vascular communications in a variety of settings. AVP II is especially useful in the closure of tubular structures with a high flow

  18. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  19. Decidual vascularization and the expression of angiogenic growth factors and proteases in first trimester spontaneous abortions

    NARCIS (Netherlands)

    Plaisier, M.; Dennert, I.; Rost, E.; Koolwijk, P.; Hinsbergh, V.W.M. van; Helmerhorst, F.M.

    2009-01-01

    BACKGROUND : Decidual vascular development is important for implantation. This study analysed decidual vascular adaptation to implantation in correlation with miscarriage in decidual secretory endometrium (DSE), decidua parietalis (DP) and decidua basalis (DB) of miscarriage patients and matched

  20. Protocol of an expertise based randomized trial comparing surgical Venae Sectio versus radiological Puncture of Vena Subclavia for insertion of Totally Implantable Access Port in oncological patients

    Directory of Open Access Journals (Sweden)

    Radeleff Boris

    2008-10-01

    Full Text Available Abstract Background Totally Implantable Access Ports (TIAP are being extensively used world-wide and can be expected to gain further importance with the introduction of new neoadjuvant and adjuvant treatments in oncology. Two different techniques for the implantation can be selected: A direct puncture of a central vein and the utilization of a Seldinger device or the surgical Venae sectio. It is still unclear which technique has the optimal benefit/risk ratio for the patient. Design A single-center, expertise based randomized, controlled superiority trial to compare two different TIAP implantation techniques. 100 patients will be included and randomized pre-operatively. All patients aged 18 years or older scheduled for primary elective implantation of a TIAP under local anesthesia who signed the informed consent will be included. The primary endpoint is the primary success rate of the randomized technique. Control Intervention: Venae Sectio will be employed to insert a TIAP by a surgeon; Experimental intervention: Punction of V. Subclavia will be used to place a TIAP by a radiologist. Duration of study: Approximately 10 months, follow up time: 90 days. Organisation/Responsibility The PORTAS 2 – Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The Center of Clinical Trials at the Department of Surgery, University Hospital Heidelberg is responsible for design and conduct of the trial including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI, University of Heidelberg. Trial Registration The trial is registered at ClinicalTrials.gov (NCT00600444.

  1. The Use of the D-STAT Dry Bandage for the Control of Vascular Access Site Bleeding: A Multicenter Experience in 376 Patients

    International Nuclear Information System (INIS)

    Hallak, Omar K.; Cubeddu, Roberto J.; Griffith, Rose A.; Reyes, Bernardo J.

    2007-01-01

    Multiple topical hemostats have been approved for control of surface bleeding from vascular access sites. The majority of these devices, however, have few clinical data supporting their use. This study was conducted to assess the efficacy and safety of the new commercially available D-Stat Dry hemostatic bandage compared to standard care manual compression. A prospective, randomized, multicenter trial was conducted in patients undergoing diagnostic cardiac catheterization or peripheral angiography utilizing femoral artery access. Subjects were randomized to either the D-Stat Dry bandage as an adjunct to manual compression or manual compression alone. Primary end points were time-to-hemostasis (TTH) and major complications. Secondary end points included minor complications, patient satisfaction, time-to-ambulation (TTA), and time-to-discharge (TTD). Three hundred seventy-six subjects (189 control, 187 investigational) with similar baseline characteristics participated in the study. The mean age was 61.5 years, with a male predominance of 58%. TTH was significantly lower in the investigational group (7.8 vs. 13.0 min; p = 0.001). No difference in major complication rates was observed between the groups. The mean TTA (investigational, 392 min, vs. control, 415 min; p = 0.023) and patient satisfaction significantly favored the investigational group (p = 0.025). No difference in TTD or the rate of minor complications was observed. This study demonstrates that in the aforementioned population, the D-Stat Dry bandage is safe and effective in reducing both TTH and TTA and results in improved patient satisfaction

  2. Adherence to standard precaution in the peripheral vascular access Siguiendo las precauciones padrón para procedimiento de inserción vascular periférico Adesão às precauções padrão no acesso vascular periférico

    Directory of Open Access Journals (Sweden)

    Melissa Alves Cirelli

    2007-06-01

    Full Text Available This prospective and quantitative study was carried out in a small private general hospital, where the adherence to standard precaution in the peripheral vascular access was evaluated. The data were collected through a questionnaire aiming to characterize the nursing team's knowledge and opinion about standard precautions and the availability of materials. In addition, a systemized observation of the procedures of vein puncture and medicine administration was performed. It was identified that 84.4% of the punctures had been carried out without gloves or previous hand washing; in 29.7% of the procedures, needles were recapped and 93.2% of the professionals reported adequate material supply. Concluding, the professionals expose themselves and patients to unnecessary risks of infection. The nursing team must be the focus of continuous interventions and future actions in order to minimize the risk of infection in the procedure of peripheral vascular access.Estudio prospectivo, cuantitativo, realizado en un hospital general privado de poca complejidad, donde fue evaluado el seguimiento de las precauciones patrón para realizar inserción vascular periférica. Los datos fueron recolectados por medio de un cuestionario, con el objetivo de determinar las características del conocimiento y de opinión del equipo de enfermería sobre los temas de adhesión, precauciones patrón, disponibilidad de materiales; y por observación sistémica de los procedimientos de punción venosa y administración de medicamentos. Se identificó que 84,4% de las punciones fueron realizadas sin guantes y sin lavado previo de manos, 29,7% de las veces hubo reutilización de agujas y 93,2% de los profesionales afirmó tener una adecuada cantidad de materiales. Se concluyó que los profesionales exponen a sus pacientes y a sí mismos a riesgos de infección innecesaria. El equipo de enfermería debe enfocar su intervención y actividades futuras con el objetivo de minimizar el

  3. Clinical Profile and Early Complications after Single and Dual Chamber Permanent Pacemaker Implantation at Manmohan Cardiothoracic Vascular and Transplant Centre, Kathmandu, Nepal.

    Science.gov (United States)

    Khanal, J; Poudyal, R R; Devkota, S; Thapa, S; Dhungana, R R

    2015-01-01

    Permanent pacemaker implantation is a minimally invasive surgical procedure in the management of patients with cardiac problems. However, complications during and after implantation are not uncommon. There is lack of evidences in rate of complications with the selection of pacemakers in Nepal. Therefore, this study was performed to compare the frequency of implantation and complication rate between single chamber and dual chamber pacemaker. The present study is based on all consecutive pacemaker implantations in a single centre between April 2014 and May 2015. A total of 116 patients were categorized into two cohorts according to the type of pacemaker implanted- single chamber or dual chamber. All patients had regular 2-weeks follow-up intervals with standardized documentation of all relevant patient data till 6-week after implantation. Data were presented as means ± standard deviation (SD) for continuous variables and as proportions for categorical variables. Comparison of continuous variables between the groups was made with independent Student's t-test. For discrete variables distribution between groups were compared with Chi-square test. The mean age (±SD) of total population at implant was 64.08 (± 15.09) years. Dual chamber units were implanted in 44 (37.93%) of patients, single chamber in 72 (62.06%). Only 14 women (31.81%) received dual chamber compared with 42 women (58.33%) who received single chamber (Chi-square=18, DF=1, P = 0.0084). Complete atrioventricular block was the commonest (56.03%) indication for permanent pacemaker insertion followed by sick sinus syndrome (33.62%), symptomatic high-grade AV block (11.20%). Hypertension (dual chamber 21.55%, single chamber 40.51%) was the most common comorbidity in both cohorts. Complications occurred in 11 (9.48%) patients. More proportion of complication occurred in single chamber group (9 patients, 12.50%) than in dual chamber (2 patients, 4.54%). Complications occurring in dual chamber group include

  4. Osseointegrated Transtibial Implants in Patients with Peripheral Vascular Disease: A Multicenter Case Series of 5 Patients with 1-Year Follow-up

    NARCIS (Netherlands)

    Atallah, R.; Li, J.J.; Lu, W.; Leijendekkers, R.A.; Frolke, J.P.M.; Muderis, M. Al

    2017-01-01

    BACKGROUND: Osseointegration is an alternative treatment for amputees who are unable to wear or have difficulty wearing a socket prosthesis. Although the majority of limb amputations are due to vascular disease, such amputations have been perceived as a contraindication to osseointegration surgery.

  5. Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction

    NARCIS (Netherlands)

    Schepers, Rutger H.; Raghoebar, Gerry M.; Vissink, Arjan; Lahoda, Lars U.; Van der Meer, W. Joerd; Roodenburg, Jan L.; Reintsema, Harry; Witjes, Max J.

    Background Reconstruction of craniofacial defects becomes complex when dental implants are included for functional rehabilitation. We describe a fully 3-dimensional (3D) digitally planned reconstruction of a mandible and immediate prosthetic loading with a fibula graft in a 2-step surgical approach.

  6. Serial assessment by optical coherence tomography of early and late vascular responses after implantation of an absorbable-coating Sirolimus-Eluting stent (from the first-in-human DESSOLVE I trial).

    Science.gov (United States)

    Attizzani, Guilherme F; Bezerra, Hiram G; Ormiston, John; Wang, Wei; Donohoe, Dennis; Wijns, William; Costa, Marco A

    2013-11-15

    The initial enthusiasm caused by the potent antirestenotic effect of early generation drug-eluting stents was recently plagued by concerns regarding their safety profile. Investigators worldwide were stimulated, therefore, to seek for improvement in drug-eluting stent technology, such as eliminating their permanent polymer blamed for vascular inflammation and delayed healing. Optical coherence tomography (OCT) assessments of stent-vessel interactions are used as a surrogate for vessel healing after DES implantation. Herewith, we report serial OCT assessments of vascular reactions to the implantation of a novel absorbable polymer sirolimus-eluting stent (MiStent). In total, 30 patients were included. At 4-, 6-, and 8-month follow-up, different groups of 10 patients underwent OCT imaging, whereas all the patients had OCT assessments scheduled at 18-month follow-up. A total of 13,569 stent struts were analyzed. Low rates of uncovered (14.34 ± 15.35%, 6.62 ± 10.93%, 3.51 ± 2.87%, and 0.84 ± 1.15%, respectively, p stent struts coupled with thin and increasingly homogenous neointimal proliferation were demonstrated. Neointimal area increased from 4- to 8-month follow-up (0.46 ± 0.29 and 1.12 ± 0.73 mm(2), respectively, p stent struts (8.8%, 3.1%, 0.3%, and 0%, respectively, p absorbable polymer sirolimus-eluting stent-vessel interactions up to 18-month follow-up. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal® Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

    International Nuclear Information System (INIS)

    Pieper, Claus Christian; Thomas, Daniel; Nadal, Jennifer; Willinek, Winfried A.; Schild, Hans Heinz; Meyer, Carsten

    2016-01-01

    PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal ® vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal ® -VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal ® -VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal ® use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general

  8. Treatment of hand ischemia following angioaccess surgery using the distal revascularization interval-ligation technique with preservation of vascular access: description of an 18-case series.

    Science.gov (United States)

    Sessa, Carmine; Riehl, Gregory; Porcu, Paolo; Pichot, Olivier; Palacin, Pedro; Maghlaoua, Mohamed; Magne, Jean-Luc

    2004-11-01

    Hand ischemia is a rare complication of angioaccess surgery for hemodialysis. Management usually requires ligation of the arteriovenous fistula (AVF). The purpose of this report is to describe our experience with the use of the distal revascularization interval-ligation (DRIL) technique for treatment of ischemia without ligation of the AVF. From January 1999 to September 2002, the DRIL technique was used to treat 18 patients (10 men, 8 women, 10 diabetic patients) with severe paresthesia of the hand (n = 9) and finger necrosis (n = 10). The AVF was located at the elbow in 16 patients and at the wrist in 2 patients. Mean flow distal to the AVF was less than 10 mL in 5 patients, less than 5 mL in 10, and unmeasurable in 3. The conduit used for all DRIL arterial bypasses, including 15 brachiobrachial bypasses, 1 axillobrachial bypass, 1 brachioradial bypass, and 1 radioradial bypass, was the great saphenous vein graft. Trophic manifestations required finger amputation in five patients, pulpar necrosis resection in four, and transmetacarpal amputation of the index finger in one patient. Symptoms disappeared in 13 patients (73%) and improved in 5 (27%). The time required for healing of finger amputations and trophic manifestations ranged from 15 days to 2 months. Mean arterial flow through the DRIL bypass was 50 mL/min (range, 20-90 mL/min). With a mean follow-up interval of 16 months (range, 5-48 months), primary patency of the DRIL artery bypass and AVF was 94% and the limb salvage rate was 100%. The DRIL technique is the most effective procedure for treatment of angioaccess-induced hand ischemia. This technique can be used to achieve persistent relief of symptoms with continued access patency. The DRIL artery bypass improves vacularization of the hand, and ligature of the artery stops the vascular steal without affecting hemodialysis access. The DRIL technique should be proposed as first-line treatment for hand ischemia due to AVF for hemodialysis.

  9. Impact of the shape of the implantable ports on their efficiency of flow (injection and flushing

    Directory of Open Access Journals (Sweden)

    Guiffant G

    2014-09-01

    Full Text Available Gérard Guiffant,1 Patrice Flaud,1 Jean Jacques Durussel,1 Jacques Merckx1,2 1Université Paris Diderot, Paris, France; 2University Teaching Hospital Necker-Enfants Malades, Paris, FranceAbstract: Now widely used, totally implantable venous access devices allow mid- and long-term, frequent, repeated, or continuous injection of therapeutic products by vascular, cavitary, or perineural access. The effective flushing of these devices is a key factor that ensures their long-lasting use. We present experimental results and a numerical simulation to demonstrate that the implementation of rounded edge wall cavities improves flushing efficiency. We use the same approaches to suggest that the deposit amount may be reduced by the use of rounded edge wall cavities. Keywords: implantable ports, totally implantable venous access devices, flushing, obstruction, prevention

  10. Effect of high ovarian response on the expression of endocrine gland-derived vascular endothelial growth factor (EG-VEGF) in peri-implantation endometrium in IVF women.

    Science.gov (United States)

    Xu, Li-Zhen; Gao, Min-Zhi; Yao, Li-Hua; Liang, A-Juan; Zhao, Xiao-Ming; Sun, Zhao-Gui

    2015-01-01

    To investigate the effect of ovarian stimulation on the expression of EG-VEGF mRNA and protein in peri-implantation endometrium in women undergoing IVF and its relation with endometrial receptivity (ER). Prospective laboratory study. University hospital. Eighteen women in stimulated cycles (SC) as study subjects and 18 women in natural cycles (NC) as controls. Women in SC group were classified with two subgroups, high ovarian response (SC1, n=9) with peak serum E2>5,000 pg/mL and moderate ovarian response (SC2, n=9) with peak serum E2 1,000-5,000 pg/mL. Endometrial biopsies were collected 6 days after ovulation in NC or after oocyte retrieval in SC. Endometrium histological dating was observed with HE staining. EG-VEGF mRNA expression levels determined by real-time polymerase chain reaction analysis, and protein levels by immunohistochemistry. All endometrial samples were in the secretory phase. The endometrial development in SC1 was 1 to 2 days advanced to NC, and with dyssynchrony between glandular and stromal tissue. Immunohistochemistry analysis showed that EG-VEGF protein was predominantly expressed in the glandular epithelial cells and endothelial cells of vessels, and also presented in the stroma. The image analysis confirmed that both the gland and stroma of endometrium in SC1 had a significantly lower EG-VEGF protein expression than that in SC2 and NC endometrium. Moreover, EG-VEGF mRNA levels were significantly lower in SC1 than in NC. Both EG-VEGF protein and mRNA levels had no significant difference between SC2 and NC. Decreased expression of EG-VEGF in the peri-implantation is associated with high ovarian response, which may account for the impaired ER and lower implantation rate in IVF cycles.

  11. Comparative vascular responses three months after paclitaxel and everolimus-eluting stent implantation in streptozotocin-induced diabetic porcine coronary arteries

    Directory of Open Access Journals (Sweden)

    Sheehy Alexander

    2012-06-01

    Full Text Available Abstract Background Diabetes remains a significant risk factor for restenosis/thrombosis following stenting. Although vascular healing responses following drug-eluting stent (DES treatment have been characterized previously in healthy animals, comparative assessments of different DES in a large animal model with isolated features of diabetes remains limited. We aimed to comparatively assess the vascular response to paclitaxel-eluting (PES and everolimus-eluting (EES stents in a porcine coronary model of streptozotocin (STZ-induced type I diabetes. Method Twelve Yucatan swine were induced hyperglycemic with a single STZ dose intravenously to ablate pancreatic β-cells. After two months, each animal received one XIENCE V® (EES and one Taxus Liberte (PES stent, respectively, in each coronary artery. After three months, vascular healing was assessed by angiography and histomorphometry. Comparative in vitro effects of everolimus and paclitaxel (10-5 M–10-12 M after 24 hours on carotid endothelial (EC and smooth muscle (SMC cell viability under hyperglycemic (42 mM conditions were assayed by ELISA. Caspase-3 fluorescent assay was used to quantify caspase-3 activity of EC treated with everolimus or paclitaxel (10-5 M, 10-7 M for 24 hours. Results After 3 months, EES reduced neointimal area (1.60 ± 0.41 mm, p vs. 0.08 ± 0.05, greater medial necrosis grade (0.52 ± 0.26 vs. 0.0 ± 0.0, and persistently elevated fibrin scores (1.60 ± 0.60 vs. 0.63 ± 0.41 with PES compared to EES (p In vitro, paclitaxel significantly increased (p -7 M, while everolimus did not affect EC/SMC apoptosis/necrosis within the dose range tested. In ECs, paclitaxel (10-5 M significantly increased caspase-3 activity (p  Conclusion After 3 months, both DES exhibited signs of delayed healing in a STZ-induced diabetic swine model. PES exhibited greater neointimal area, increased inflammation, greater medial necrosis, and

  12. Risk factors for central line-associated bloodstream infection in pediatric oncology patients with a totally implantable venous access port: A cohort study.

    Science.gov (United States)

    Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves

    2017-02-01

    Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.

  13. The Sound Access Parent Outcomes Instrument (SAPOI): Construction of a new instrument for children with severe multiple disabilities who use cochlear implants or hearing aids.

    Science.gov (United States)

    Hayward, Denyse V; Ritter, Kathryn; Mousavi, Amin; Vatanapour, Shabnam

    2016-01-01

    To report on the Phase 2 development of the Sound Access Parent Outcomes Instrument (SAPOI), a new instrument focused on formalizing outcomes that parents of children with severe multiple disabilities (SMD) who use amplification prioritize as important. Phase 2 of this project involved item selection and refinement of the SAPOI based on (a) Phase 1 study participant input, (b) clinical specialist feedback, and (c) test-retest instrument reliability. Phase 1 participant responses were utilized to construct a draft version of the SAPOI. Next, clinical specialists examined the instrument for content validity and utility and instrument reliability was examined through a test-retest process with parents of children with SMD. The draft SAPOI was constructed based on Phase 1 participant input. Clinical specialists supported content validity and utility of the instrument and the inclusion of 19 additional items across four categories, namely Child Affect, Child Interaction, Parent Well-being, and Child's Device Use. The SAPOI was completed twice at one-month intervals by parents of children with SMD to examine instrument reliability across the four categories (Child Affect, Child Interaction, Parent Well-being, and Child's Device Use). Instrument reliability was strong-to-excellent across all four sections. The SAPOI shows promise as a much-needed addition to the assessment battery currently used for children with SMD who use cochlear implants and hearing aids. It provides valuable information regarding outcomes resulting from access to sound in this population that currently used assessments do not identify.

  14. Implant rehabilitation in fibula-free flap reconstruction: A retrospective study of cases at 1-18 years following surgery.

    Science.gov (United States)

    Sozzi, Davide; Novelli, Giorgio; Silva, Rebeka; Connelly, Stephen T; Tartaglia, Gianluca M

    2017-10-01

    To determine the dental implant and prostheses success rate in a cohort of patients who underwent a vascularized fibula-free flap (FFF) for maxillary or mandibular reconstruction. The investigators implemented a retrospective cohort study composed of patients who had undergone primary or secondary FFF reconstruction jaw surgery plus placement of 2-6 implants in the reconstructed arch, which were restored with an implant-supported prosthesis. The sample was composed of all patients who underwent FFF surgery between 1998 and 2012 and had either simultaneous or secondary dental implant placement. A total of 28 patients met inclusion criteria. Of these, 22 patients participated in the retrospective review. Patients were examined by an independent observer between January-December 2015. In addition, all patients completed a questionnaire to access satisfaction with the implant-supported prosthesis. The patient cohort consisted of 12 males and 10 females, age 12-70 years. A total of 100 implants were placed, 92 implants in fibular bone and 8 implants in native bone. In the maxilla, 35 implants were placed into fibular bone and 4 into native bone (11 in irradiated patients and 28 in non-irradiated patients). In the mandible, 57 implants were placed into fibular bone and 4 into native bone (15 in irradiated patients and 46 in non-irradiated patients). The mean follow-up after implant loading was 7.8 years (range 1.3-17.5 years). The implant survival rate was 98% (95% CI: 92.2%-99.5%). No statistically significant difference was found in implant success between maxillary and mandibular implants, or between radiated and non-radiated bone. The prostheses success rate, determined by clinical exam and patient satisfaction, was 100%. The results of this study suggest that implant survival is high and implant-supported prostheses are a reliable rehabilitation option in patients whose jaws have been reconstruction with a FFF. Copyright © 2017. Published by Elsevier Ltd.

  15. Amplatzer vascular plugs in congenital cardiovascular malformations

    Directory of Open Access Journals (Sweden)

    Parag Barwad

    2013-01-01

    Full Text Available Background: Amplatzer vascular plugs (AVPs are devices ideally suited to close medium-to-large vascular communications. There is limited published literature regarding the utility of AVPs in congenital cardiovascular malformations (CCVMs. Aims: To describe the use of AVPs in different CCVMs and to evaluate their safety and efficacy. Materials and Methods: All patients who required an AVP for the closure of CCVM were included in this retrospective review of our catheterization laboratory data. The efficacy and safety of AVPs are reported. Results: A total of 39 AVPs were implanted in 31 patients. Thirteen (33% were AVP type I and 23 (59% were AVP type II. AVP type III were implanted in two patients and type IV in one patient. The major indications for their use included closure of pulmonary arteriovenous malformation (AVM (n = 7, aortopulmonary collaterals (n = 7, closure of a patent Blalock-Taussig shunt (n = 5, systemic AVM (n = 5, coronary AVM (n = 4, patent ductus arteriosus (PDA (n = 3, pulmonary artery aneurysms (n = 3, and venovenous collaterals (n = 2. Deployment of the AVP was done predominantly via the 5 - 7F Judkin′s right coronary guide catheter. Overall 92% of the AVPs could be successfully deployed and resulted in occlusion of the target vessel in all cases, within 10 minutes. No procedure-related or access site complication occurred. Conclusions: AVPs are versatile, easy to use, and effective devices to occlude the vascular communications in a variety of settings. AVP II is especially useful in the closure of tubular structures with a high flow.

  16. Hyperglycemia-Induced Modulation of the Physiognomy and Angiogenic Potential of Fibroblasts Mediated by Matrix Metalloproteinase-2: Implications for Venous Stenosis Formation Associated with Hemodialysis Vascular Access in Diabetic Milieu.

    Science.gov (United States)

    Janardhanan, Rajiv; Kilari, Sreenivasulu; Leof, Edward B; Misra, Sanjay

    2015-01-01

    It is hypothesized that venous stenosis formation associated with hemodialysis vascular-access failure is caused by hypoxia-mediated fibroblast-to-myofibroblast differentiation accompanied by proliferation and migration, and that diabetic patients have worse clinical outcomes. The aim of this study was to determine the functional and gene expression outcomes of matrix metalloproteinase-2 (Mmp-2) silencing in fibroblasts cultured under hyperglycemia and euglycemia with hypoxic and normoxic stimuli. AKR-2B fibroblasts were stably transduced using lentivirus-mediated shRNA-Mmp-2 or scrambled controls and subjected to hypoxia or normoxia under hyperglycemic or euglycemic conditions for 24 and 72 h. Gene expression of vascular endothelial growth factor-A (Vegf-A), Vegfr-1, Mmp-2, Mmp-9 and tissue inhibitors of matrix metalloproteinases (Timps) were determined by RT-PCR. Collagen I and IV secretion and cellular proliferation and migration were determined. Under hyperglycemic conditions, there is a significant reduction in the average gene expression of Vegf-A and Mmp-9, with an increase in Timp-1 at 24 h of hypoxia (p < 0.05) in Mmp-2-silenced fibroblasts when compared to controls. In addition, there is a decrease in collagen I and IV secretion and cellular migration. The euglycemic cells were able to reverse these findings. These findings demonstrate the rationale for using anti-Mmp-2 therapy in dialysis patients with hemodialysis vascular access in helping to reduce stenosis formation. © 2016 The Author(s) Published by S. Karger AG, Basel.

  17. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  18. Influence of space size of abutment screw access channel on the amount of extruded excess cement and marginal accuracy of cement-retained single implant restorations.

    Science.gov (United States)

    Al Amri, Mohammad D; Al-Johany, Sulieman S; Al-Qarni, Mohammed N; Al-Bakri, Ahmed S; Al-Maflehi, Nassr S; Abualsaud, Haythem S

    2018-02-01

    The detrimental effect of extruded excess cement on peri-implant tissue has been well documented. Although several techniques have been proposed to reduce this effect by decreasing the amount of extruded cement, how the space size of the abutment screw access channel (SAC) affects the amount of extruded cement and marginal accuracy is unclear. The purpose of this in vitro study was to evaluate the effect of the size of the unfilled space of the abutment SAC on the amount of extruded excess cement and the marginal accuracy of zirconia copings. Twelve implant replicas and corresponding standard abutments were attached and embedded in acrylic resin blocks. Computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia copings with a uniform 30-μm cement space were fabricated by 1 dental technician using the standard method. The copings were temporarily cemented 3 times at different sizes of the left space of the SAC as follows: the nonspaced group (NS), in which the entire SAC was completely filled, the 1-mm-spaced group (1MMS), and the 2-mm-spaced group (2MMS). Abutments and crowns were ultrasonically cleaned, steam cleaned, and air-dried. The excess cement was collected and weighed. To measure the marginal accuracy, 20 measurements were made every 18 degrees along the coping margin at ×300 magnification and compared with the pre-cementation readings. One-way ANOVA was calculated to determine whether the amount of extruded excess cement differed among the 3 groups, and the Tukey test was applied for multiple comparisons (α=.05). The mean weights (mg) of extruded excess cement were NS (33.53 ±1.5), 1MMS (22.97 ±5.4), and 2MMS (15.17 ±5.9). Multiple comparisons showed significant differences in the amount of extruded excess cement among the 3 test groups (Pcemented group (29.5 ±8.2) was significantly different (Pcement by 55% in comparison with the nonspaced abutments. However, no effect was found on the marginal accuracy of zirconia copings

  19. Acesso vascular para hemodiálise com cateter temporário de duplo lúmen em cães com insuficiência renal aguda Hemodialysis vascular access with temporary double-lumen catheter in dogs with acute renal failure

    Directory of Open Access Journals (Sweden)

    Alessandra Melchert

    2008-08-01

    Full Text Available A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA, enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD, com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%, devido à obstrução do lúmen do cateter em seis sessões (5,8% ou por saída acidental do mesmo em uma sessão (1,0%. Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.Hemodialysis is a therapeutic procedure that can sustain the patient's life in acute renal failure (ARF, during the renal function recover. To perform hemodialysis (HD, an extracorporeal circulation is established to blood filtration, imposing the need of a viable and efficient vascular access. The aim of this study was to evaluate the effectiveness and complications of the HD vascular access with temporary double-lumen catheter inserted into the external jugular vein. Ten mongrel dogs with ARF, induced by gentamicin administration, were submitted to daily

  20. Modificações na angulação coronária após implante de suporte vascular bioabsorvível e de stents de cromo-cobalto e aço inoxidável

    OpenAIRE

    Silva, Mateus Veloso e; Costa Jr., J. Ribamar; Abizaid, Alexandre; Staico, Rodolfo; Taiguara, Danillo; Borghi Jr., Tarcísio Campostrini; Costa, Ricardo; Chamié, Daniel; Sousa, Amanda G. M. R.; Sousa, J. Eduardo

    2013-01-01

    INTRODUÇÃO: A conformabilidade do stent, definida como a adaptação da prótese à forma natural do vaso, é a principal responsável pelas alterações geométricas produzidas após o implante do dispositivo, sendo influenciada pelo material e pelo desenho do stent. Ela pode ser aferida medindo-se as modificações da curvatura e a angulação do segmento tratado após o implante do stent. O objetivo deste estudo foi comparar as mudanças na angulação coronária após implante do suporte vascular bioabsorvív...

  1. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  2. Comparison of two indwelling central venous access catheters in dogs undergoing fractionated radiotherapy

    International Nuclear Information System (INIS)

    Evans, K.L.; Smeak, D.D.; Couto, C.G.; Hammer, A.S.; Gaynor, J.S.

    1994-01-01

    Twenty dogs with neoplasms requiring multiple radiation treatments received either percutaneous vascular access catheters (PVACs; Cook, Bloomington, IN) or subcutaneous vascular access ports (SVAPs; Vascular-Access-Ports, Norfolk Medical Products, Inc., Skokie, IL); 10 dogs were entered in each group. All catheters were implanted and removed aseptically and the catheter tips were cultured during implant removal. Complications with PVACs included mild incisional swelling and redness and accidental severance or rupture of the catheter. Complications with SVAPs included incisional or port swelling, bruising or redness, hematoma formation, and pain. Ports in 4 of these dogs could not be used for 1 to 3 days after surgery because of swelling and pain. Surgical wound complications, when pooled for comparison, occurred significantly more frequently with the SVAPs (P = .023). Wound complications associated with both catheters were self-limiting and resolved within 7 days. Bacterial cultures were positive in two PVACs and four SVAP tips, however, none of these dogs had clinical signs of infection or sepsis. Although both types of indwelling catheters were functional in a clinical setting, PVACs were preferred to SVAPs for dogs undergoing radiation therapy because of decreased time for implantation and fewer overall complications

  3. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of the success rate of cone beam computed tomography in determining the location and direction of screw access holes in cement-retained implant-supported prostheses: An in vitro study.

    Science.gov (United States)

    Neshandar Asli, Hamid; Dalili Kajan, Zahra; Gholizade, Fatemeh

    2018-02-21

    Cement-retained implant-supported restorations have advantages over screw-retained restorations but are difficult to retrieve. Identifying the approximate location of the screw access hole (SAH) may reduce damage to the prosthesis. The purpose of this in vitro study was to evaluate the ability of cone beam computed tomography (CBCT) imaging to determine the location and direction of SAHs in cement-retained implant prostheses. Five clear acrylic resin casts were made based on a mandibular model. Several implant osteotomies (n=30) were created on the models with surgical burs, and crowns were made using the standard laboratory method with a transfer coping and the closed tray impression technique. CBCT images from the acrylic resin casts were evaluated by a maxillofacial radiologist who was blind to the locations and angles of the osteotomies. The locations of the access holes were determined on multiplanar reconstruction images and transferred to the clinical crown surface as defined points. Based on cross-sectional images, the predicted angle of the access hole was provided to a prosthodontist who was requested to pierce the crown at the proposed location in the specified direction. If the location and/or direction of the access hole were found, the process was considered successful, as the crown could then be removed from the implant abutment through the SAH. The success rate in the detection of the location and direction of the SAH was calculated, and chi-square and Fisher exact tests were applied for data analysis (α=.05). According to the results of this study, the success rate of CBCT to define the location of SAHs was 83.3% and 80% to determine the direction. No significant differences were found among the different dental groups in determination of the location (P=.79) or the direction (P=.53) of the SAHs. Most of the failures in determining the location and direction of the access hole in the buccolingual and mesiodistal directions were in the buccal and

  5. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. VASCULAR SURGERY

    African Journals Online (AJOL)

    2016-06-02

    Jun 2, 2016 ... with the literature from South Africa over the last four decades, and reflects the high rate of interpersonal violence in the country.14,15 As expected, cervical ... via the intact circle of Willis in young patients is the most likely explanation for the lack of strokes. Five patients were referred to the Durban vascular ...

  7. Vascular Disorders

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Vascular Disorders Email to a friend * required fields ...

  8. Biomimicry, vascular restenosis and coronary stents.

    Science.gov (United States)

    Schwartz, R S; van der Giessen, W J; Holmes, D R

    1998-01-01

    Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.

  9. Short-term and long-term outcome of radiological-guided insertion of central venous access port devices implanted at the forearm: a retrospective monocenter analysis in 1704 patients

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz; Borgmeyer, Sebastian; Gaa, Jochen; Meier, Reinhard; Berger, Hermann [Technische Universitaet Muenchen, Division of Interventional Radiology, Department of Radiology, Klinikum Rechts der Isar, Muenchen (Germany); Haller, Bernhard [Technische Universitaet Muenchen, Department of Medical Statistics and Epidemiology, Klinikum Rechts der Isar, Munich (Germany); Jansen, Heike; Kiechle, Marion; Ettl, Johannes [Technische Universitaet Muenchen, Department of Obstetrics and Gynecology, Klinikum Rechts der Isar, Munich (Germany)

    2014-09-20

    The objectives are to analyze the technical success rate as well as the short-term and long-term complications of totally implantable venous access ports (TIVAPs) at the forearm. Retrospective analysis of 1,704 consecutively implanted TIVAPs was performed. Primary endpoints were defined as technical success rate, clinical outcome, device service interval, and rates of major complications. Minor complications not requiring port explantation were defined as secondary endpoints. The technical success rate was 99.2 % with no major complications. During follow-up, a total of 643,200 catheter-days were documented, the mean device service interval was 380.6 days/patient. A total of 243 complications (14.4 %) in 226 patients were observed (0.4/1000 catheter-days), in 140 patients (8.3 %) the port device had to be explanted. Disconnection between the port device and the catheter (1.6 %) was more frequent than fracture (0.8 %) and leakage (0.6 %) of the catheter, which occurred more frequently when the catheter was inserted via the cephalic versus the brachial vein. TIVAP implantation at the forearm is a simple and safe procedure with a low rate of early and late complications. (orig.)

  10. Preventing AVF thrombosis: the rationale and design of the Omega-3 fatty acids (Fish Oils and Aspirin in Vascular access OUtcomes in REnal Disease (FAVOURED study

    Directory of Open Access Journals (Sweden)

    Rosman Johan

    2009-01-01

    Full Text Available Abstract Background Haemodialysis (HD is critically dependent on the availability of adequate access to the systemic circulation, ideally via a native arteriovenous fistula (AVF. The Primary failure rate of an AVF ranges between 20–54%, due to thrombosis or failure of maturation. There remains limited evidence for the use of anti-platelet agents and uncertainty as to choice of agent(s for the prevention of AVF thrombosis. We present the study protocol for a randomised, double-blind, placebo-controlled, clinical trial examining whether the use of the anti-platelet agents, aspirin and omega-3 fatty acids, either alone or in combination, will effectively reduce the risk of early thrombosis in de novo AVF. Methods/Design The study population is adult patients with stage IV or V chronic kidney disease (CKD currently on HD or where HD is planned to start within 6 months in whom a planned upper or lower arm AVF is to be the primary HD access. Using a factorial-design trial, patients will be randomised to aspirin or matching placebo, and also to omega-3 fatty acids or matching placebo, resulting in four treatment groups (aspirin placebo/omega-3 fatty acid placebo, aspirin/omega-3 fatty acid placebo, aspirin placebo/omega-3 fatty acid, aspirin/omega-3 fatty acid. Randomisation will be achieved using a dynamic balancing method over the two stratification factors of study site and upper versus lower arm AVF. The medication will be commenced pre-operatively and continued for 3 months post surgery. The primary outcome is patency of the AVF at three months after randomisation. Secondary outcome measures will include functional patency at six and twelve months, primary patency time, secondary (assisted patency time, and adverse events, particularly bleeding. Discussion This multicentre Australian and New Zealand study has been designed to determine whether the outcome of surgery to create de novo AVF can be improved by the use of aspirin and/or omega-3 fatty

  11. Preventing AVF thrombosis: the rationale and design of the Omega-3 fatty acids (Fish Oils) and Aspirin in Vascular access OUtcomes in REnal Disease (FAVOURED) study.

    Science.gov (United States)

    Irish, Ashley; Dogra, Gursharan; Mori, Trevor; Beller, Elaine; Heritier, Stephane; Hawley, Carmel; Kerr, Peter; Robertson, Amanda; Rosman, Johan; Paul-Brent, Peta-Anne; Starfield, Melissa; Polkinghorne, Kevan; Cass, Alan

    2009-01-21

    Haemodialysis (HD) is critically dependent on the availability of adequate access to the systemic circulation, ideally via a native arteriovenous fistula (AVF). The Primary failure rate of an AVF ranges between 20-54%, due to thrombosis or failure of maturation. There remains limited evidence for the use of anti-platelet agents and uncertainty as to choice of agent(s) for the prevention of AVF thrombosis. We present the study protocol for a randomised, double-blind, placebo-controlled, clinical trial examining whether the use of the anti-platelet agents, aspirin and omega-3 fatty acids, either alone or in combination, will effectively reduce the risk of early thrombosis in de novo AVF. The study population is adult patients with stage IV or V chronic kidney disease (CKD) currently on HD or where HD is planned to start within 6 months in whom a planned upper or lower arm AVF is to be the primary HD access. Using a factorial-design trial, patients will be randomised to aspirin or matching placebo, and also to omega-3 fatty acids or matching placebo, resulting in four treatment groups (aspirin placebo/omega-3 fatty acid placebo, aspirin/omega-3 fatty acid placebo, aspirin placebo/omega-3 fatty acid, aspirin/omega-3 fatty acid). Randomisation will be achieved using a dynamic balancing method over the two stratification factors of study site and upper versus lower arm AVF. The medication will be commenced pre-operatively and continued for 3 months post surgery. The primary outcome is patency of the AVF at three months after randomisation. Secondary outcome measures will include functional patency at six and twelve months, primary patency time, secondary (assisted) patency time, and adverse events, particularly bleeding. This multicentre Australian and New Zealand study has been designed to determine whether the outcome of surgery to create de novo AVF can be improved by the use of aspirin and/or omega-3 fatty acids. Recently a placebo-controlled trial has shown that

  12. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  13. 269. Veinte años de experiencia con homoinjertos vasculares criopreservados en la infección vascular

    Directory of Open Access Journals (Sweden)

    E. Quintana

    2012-04-01

    Conclusiones: Este estudio a largo plazo contribuye a mantener la indicación para el implante de homoinjertos vasculares criopreservados en las infecciones vasculares. Los resultados demuestran un comportamiento satisfactorio en esta población multimórbida.

  14. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  15. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  16. [Value of preserved saphenous vein graft for the creation of access ports in hemodialyzed patients: report of 309 cases].

    Science.gov (United States)

    Schneider, Marc; Barrou, Benoît; Cluzel, Philippe; Hamani, Aziz; Bitker, Marc-Olivier; Richard, François

    2003-09-01

    Biological grafts are rarely used for the creation of vascular access, despite their many advantages. Our group prefers to use distal vascular accesses with interposition of a biological graft when direct access cannot be achieved. The objective of this study was to determine the long-term patency and the complication rate of a series of 309 vascular access procedures using a preserved saphenous (PS) vein homograft. 410 (27%) of the 1,500 vascular access procedures performed by our group required the use of a graft, including 376 PS vein homografts (25%). This retrospective study comprised complete data collection for 309 arteriovenous fistulas (AVF) using preserved saphenous (PS) vein graft in the forearm performed in 267 patients between 1985 and 2000. Primary patency was defined as the interval between creation of the vascular access and the first complication requiring surgical or radiological correction; secondary patency was defined as the interval between creation and loss of the graft, with or without revision of the fistula. Survival rates were calculated according to the Kaplan-Meier method. Inter-group comparison was performed by the Logrank test and analysis of variance was performed by logistic regression. Primary patency rates were 77%, 40% and 27% at 1,2 and 5 years, respectively. Secondary patency rates were 79% and 47% at 1 year and 5 years, respectively. The thrombosis rate was 42%. Two episodes of thrombosis occurred in 25% of grafts and 3 episodes were observed in 10% of cases. Infection rates were 1.9% postoperatively and 5% after dialysis, respectively. An aneurysm occurred on 10% of grafts. The operator's experience (RR = 1.58; p creation of vascular accesses with similar patency rates to those of prosthetic grafts. Vein grafts present a number of advantages, particularly a greater ease of use facilitating distal implantation of the graft and a low infection rate.

  17. Venous access: options, approaches and issues

    International Nuclear Information System (INIS)

    Asch, M.R.

    2001-01-01

    Venous access is an essential part of medical practice. It is needed to obtain blood samples to make the diagnosis and to administer fluids or medicines as part of treatment. Although relatively new in the history of medicine, the placement and maintenance of the various venous access devices now occupies a significant portion of many vascular and interventional radiology practices. Thus, it is important to have a thorough understanding of these devices and their uses. The first long-term venous access devices were used in 1973. These were placed via a surgical cut-down on the subclavian vein. In 1982, the first subcutaneous implantable ports were described. These procedures were initially performed by surgeons, but over the last 5-10 years, both the insertion and management of these devices has shifted to interventional radiologists. Peripherally inserted central catheter (PICC) lines have almost completely supplanted the use of standard central lines (Fig. 1). A number of factors have facilitated this - namely, ready and less expensive room access, outpatient procedure and radiologists' accessibility and familiarity with image-guidance procedures and catheters and guide wires. (author)

  18. REDUCED THROMBOGENICITY OF VASCULAR PROSTHESES BY COATING WITH ADP-ASE

    NARCIS (Netherlands)

    VANDERLEI, B; ROBINSON, PH; BAKKER, WW; Bartels, H.

    1992-01-01

    In this pilot study ADP-ase coated polyurethane (PL) vascular prostheses and noncoated (control) PU vascular prostheses (all vascular prostheses: ID 1.5 mm, length 1,5 cm) were implanted into the carotid artery of the rabbit to test wheter ADP-ase might function as an adequate anti-thrombogenic

  19. Engineering the mechanical and biological properties of nanofibrous vascular grafts for in situ vascular tissue engineering.

    Science.gov (United States)

    Henry, Jeffrey J D; Yu, Jian; Wang, Aijun; Lee, Randall; Fang, Jun; Li, Song

    2017-08-17

    Synthetic small diameter vascular grafts have a high failure rate, and endothelialization is critical for preventing thrombosis and graft occlusion. A promising approach is in situ tissue engineering, whereby an acellular scaffold is implanted and provides stimulatory cues to guide the in situ remodeling into a functional blood vessel. An ideal scaffold should have sufficient binding sites for biomolecule immobilization and a mechanical property similar to native tissue. Here we developed a novel method to blend low molecular weight (LMW) elastic polymer during electrospinning process to increase conjugation sites and to improve the mechanical property of vascular grafts. LMW elastic polymer improved the elasticity of the scaffolds, and significantly increased the amount of heparin conjugated to the micro/nanofibrous scaffolds, which in turn increased the loading capacity of vascular endothelial growth factor (VEGF) and prolonged the release of VEGF. Vascular grafts were implanted into the carotid artery of rats to evaluate the in vivo performance. VEGF treatment significantly enhanced endothelium formation and the overall patency of vascular grafts. Heparin coating also increased cell infiltration into the electrospun grafts, thus increasing the production of collagen and elastin within the graft wall. This work demonstrates that LMW elastic polymer blending is an approach to engineer the mechanical and biological property of micro/nanofibrous vascular grafts for in situ vascular tissue engineering.

  20. Extracellular Matrix Molecules Facilitating Vascular Biointegration

    Directory of Open Access Journals (Sweden)

    Martin K.C. Ng

    2012-08-01

    Full Text Available All vascular implants, including stents, heart valves and graft materials exhibit suboptimal biocompatibility that significantly reduces their clinical efficacy. A range of biomolecules in the subendothelial space have been shown to play critical roles in local regulation of thrombosis, endothelial growth and smooth muscle cell proliferation, making these attractive candidates for modulation of vascular device biointegration. However, classically used biomaterial coatings, such as fibronectin and laminin, modulate only one of these components; enhancing endothelial cell attachment, but also activating platelets and triggering thrombosis. This review examines a subset of extracellular matrix molecules that have demonstrated multi-faceted vascular compatibility and accordingly are promising candidates to improve the biointegration of vascular biomaterials.

  1. Risk of infection due to medical interventions via central venous catheters or implantable venous access port systems at the middle port of a three-way cock: luer lock cap vs. luer access split septum system (Q-Syte).

    Science.gov (United States)

    Pohl, Fabian; Hartmann, Werner; Holzmann, Thomas; Gensicke, Sandra; Kölbl, Oliver; Hautmann, Matthias G

    2014-01-25

    Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with disconnection and reconnection of the standard luer lock cap (referred as "intervention"), we compared luer lock caps with a "closed access system" consisting of a luer access split septum system with regard to process optimization (work simplification, process time), efficiency (costs) and hygiene (patient safety). For determination of process optimization the workflow of an intervention according to the usual practice and risks was depicted in a process diagram. For determining the actual process costs, we analyzed use of material and time parameters per intervention and used the process parameters for programming the process into a simulation run (n = 1000) to determine the process costs as well as their differences (ACTUAL vs. NOMINAL) within the framework of a discrete event simulation.Additionally cultures were carried out at the TWC C-ports to evaluate possible contamination. With the closed access system, the mean working time of 5.5 minutes could be reduced to 2.97 minutes. The results for average process costs (labour and material costs per use) were 3.92 € for luer lock caps and 2.55 € for the closed access system. The hypothesis test (2-sample t-test, CI 0.95, p-valuerisks (related to material, surroundings, staff handling) could be reduced by 65.38%. In the present research, the closed access system with a divided split septum was superior to conventional luer lock caps. The advantage of the closed access system lies in the simplified handling for staff, which results in a reduced risk of patient infection due to improved clinical hygiene.

  2. A simple tissue model for practicing ultrasound guided vascular ...

    African Journals Online (AJOL)

    Introduction: The use of ultrasound in anaesthetic practice continues to be more established and the use of ultrasound guidance in establishing vascular access is recommended by various groups. We have developed a tissue model for the practice and skills development in ultrasound vascular access. Method: The tissue ...

  3. Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal{sup ®} Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: claus.christian.pieper@ukb.uni-bonn.de; Thomas, Daniel, E-mail: daniel.thomas@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Nadal, Jennifer, E-mail: jennifer.nadal@ukb.uni-bonn.de [University of Bonn, Institute for Medical Biometry, Informatics and Epidemiology (Germany); Willinek, Winfried A., E-mail: w.willinek@bk-trier.de; Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Meyer, Carsten, E-mail: carsten.meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2016-01-15

    PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.

  4. CIRSE Vascular Closure Device Registry

    International Nuclear Information System (INIS)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Purpose: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only 5.9 cm, and two vessel occlusions. Conclusion: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.

  5. CIRSE Vascular Closure Device Registry

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2010-01-01

    Purpose Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only 5.9 cm, and two vessel occlusions. Conclusion The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters. PMID:20981425

  6. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  7. [Significance of various implantate localizations of Sparks prostheses, experimental studies in rats].

    Science.gov (United States)

    Brieler, H S; Parwaresch, R; Thiede, A

    1976-01-01

    Our investigations show that Sparks prostheses after subcutaneous implantation are suitable for vascular grafting. At the end of the organization period the connective tissue becomes strong, and after the third and fourth weeks collagenous and elastic fibers can be seen. Ten weeks after s.c. implantation, collagenous fibers predominate. After this the Sparks prostheses can be used as a vascular graft. Intraperitoneal implantation, however, shows a histologically different picture with characteristic findings: only fat cells can be observed, a strong granulation tissue with elastic and collagenous fibers is not present. After intraperitoneal implantation Sparks prostheses are therefore unsuitable for vascular grafts.

  8. Port type is a possible risk factor for implantable venous access port-related bloodstream infections and no sign of local infection predicts the growth of gram-negative bacilli.

    Science.gov (United States)

    Hsu, Jui-Feng; Chang, Hsu-Liang; Tsai, Ming-Ju; Tsai, Ying-Ming; Lee, Yen-Lung; Chen, Pei-Huan; Fan, Wen-Chieh; Su, Yu-Chung; Yang, Chih-Jen

    2015-09-30

    Implantable venous access port (IVAP)-related blood stream infections (BSIs) are one of the most common complications of implantable venous ports. The risk factors and pathogens for IVAP-related BSIs are still controversial. We retrospectively reviewed all patients who received IVAPs at a Hospital in Taiwan from January 1, 2011 to June 31, 2014. Two types of venous port, BardPort® 6.6 fr (Bard port) and Autosuture Chemosite® 7.5 fr (TYCO port) were used. All patients with clinically proven venous port-related BSIs were enrolled. A total of 552 patients were enrolled. There were 34 episodes of IVAP-related BSIs during the study period for a total incidence of 0.177 events/1000 catheter days. Port type (TYCO vs. Bard, HR = 7.105 (95% confidence interval (CI), 1.688-29.904), p = 0.0075), age > 65 years (HR = 2.320 (95 % CI, 1.179-4.564), p = 0.0148), and lung cancer (HR = 5.807 (95% CI, 2.946-11.447), p port infections. We also found that no local sign of infection was significantly associated with the growth of gram-negative bacilli (p = 0.031). TYCO venous ports, age > 65 years, and lung cancer were all significant risk factors for IVAP-related BSIs, and no sign of infection was significantly associated with the growth of gram-negative bacilli.

  9. Measurement of cardiac index by transpulmonary thermodilution using an implanted central venous access port: a prospective study in patients scheduled for oncologic high-risk surgery.

    Science.gov (United States)

    Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire

    2014-01-01

    Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (-0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. clinicaltrials.gov NCT02063009.

  10. Bioprinting for vascular and vascularized tissue biofabrication.

    Science.gov (United States)

    Datta, Pallab; Ayan, Bugra; Ozbolat, Ibrahim T

    2017-03-15

    Bioprinting is a promising technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision. Bioprinting enables the deposition of various biologics including growth factors, cells, genes, neo-tissues and extra-cellular matrix-like hydrogels. Benefits of bioprinting have started to make a mark in the fields of tissue engineering, regenerative medicine and pharmaceutics. Specifically, in the field of tissue engineering, the creation of vascularized tissue constructs has remained a principal challenge till date. However, given the myriad advantages over other biofabrication methods, it becomes organic to expect that bioprinting can provide a viable solution for the vascularization problem, and facilitate the clinical translation of tissue engineered constructs. This article provides a comprehensive account of bioprinting of vascular and vascularized tissue constructs. The review is structured as introducing the scope of bioprinting in tissue engineering applications, key vascular anatomical features and then a thorough coverage of 3D bioprinting using extrusion-, droplet- and laser-based bioprinting for fabrication of vascular tissue constructs. The review then provides the reader with the use of bioprinting for obtaining thick vascularized tissues using sacrificial bioink materials. Current challenges are discussed, a comparative evaluation of different bioprinting modalities is presented and future prospects are provided to the reader. Biofabrication of living tissues and organs at the clinically-relevant volumes vitally depends on the integration of vascular network. Despite the great progress in traditional biofabrication approaches, building perfusable hierarchical vascular network is a major challenge. Bioprinting is an emerging technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision

  11. Imaging of implants on chest radiographs: a radiological perspective

    International Nuclear Information System (INIS)

    Burney, K.; Thayur, N.; Husain, S.A.; Martin, R.P.; Wilde, P.

    2007-01-01

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant

  12. Imaging of implants on chest radiographs: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Thayur, N [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Husain, S A [Department of Respiratory Medicine, Bristol Royal Infirmary (United Kingdom); Martin, R P [Department of Cardiology, Bristol Royal Hospital for Children, Bristol (United Kingdom); Wilde, P [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom)

    2007-03-15

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant.

  13. Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients.

    Science.gov (United States)

    Misterski, Marcin; Puślecki, Mateusz; Grygier, Marek; Olasińska-Wiśniewska, Anna; Lesiak, Maciej; Araszkiewicz, Aleksander; Perek, Barłomiej; Choręziak, Aneta; Lindner, Jacek; Komosa, Anna; Buczkowski, Piotr; Ligowski, Marcin; Katarzyński, Sławomir; Jemielity, Marek

    2017-06-01

    Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. To evaluate the results of transapical access in transcatheter aortic valve implantation (TAVI) among patients with unsuitable vascular access. All patients had been assessed by a local heart team and were disqualified from surgical aortic valve replacement (AVR) and the transfemoral TAVI approach. Mean age was 75.4 ±3.9 years (range: 68-80), with 20% being female. Logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and STS (Society of Thoracic Surgeons) were 15.4 ±8.9% and 20.5 ±4.5%, respectively. All implantations were performed successfully in the intra-annular and subcoronary position. There were no conversions to surgical AVR. All patients survived 30-day follow-up. No strokes or transient ischemic attacks were reported. There was no need for pacemaker implantation and none of the patients demonstrated moderate or significant paravalvular leakage. The mean aortic gradients improved significantly from a baseline of 57.0 ±19.2 mm Hg to a 30-day value of 14.2 ±4.1 mm Hg. Our initial clinical results indicate satisfactory functionality in patients after trans-apical implantation of the Symetis Acurate aortic valve. The procedure of implantation seems to be straightforward and may be considered in patients in whom a transfemoral approach is not a good option.

  14. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  15. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  16. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  18. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  19. Expanded polytetrafluoroethylene membrane alters tissue response to implanted Ahmed glaucoma valve.

    Science.gov (United States)

    DeCroos, Francis Char; Ahmad, Sameer; Kondo, Yuji; Chow, Jessica; Mordes, Daniel; Lee, Maria Regina; Asrani, Sanjay; Allingham, R Rand; Olbrich, Kevin C; Klitzman, Bruce

    2009-07-01

    Long-term intraocular pressure control by glaucoma drainage implants is compromised by the formation of an avascular fibrous capsule that surrounds the glaucoma implant and increases aqueous outflow resistance. It is possible to alter this fibrotic tissue reaction and produce a more vascularized and potentially more permeable capsule around implanted devices by enclosing them in a porous membrane. Ahmed glaucoma implants modified with an outer 5-microm pore size membrane (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) and unmodified glaucoma implants were implanted into paired rabbit eyes. After 6 weeks, the devices were explanted and subject to histological analysis. A tissue response containing minimal vascularization, negligible immune response, and a thick fibrous capsule surrounded the unmodified Ahmed glaucoma implant. In comparison, the tissue response around the PRIME-Ahmed demonstrated a thinner fibrous capsule (46.4 +/- 10.8 microm for PRIME-Ahmed versus 94.9 +/- 21.2 microm for control, p vascularized near the tissue-material interface. A prominent chronic inflammatory response was noted as well. Encapsulating the aqueous outflow pathway with a porous membrane produces a more vascular tissue response and thinner fibrous capsule compared with a standard glaucoma implant plate. Enhanced vascularity and a thinner fibrous capsule may reduce aqueous outflow resistance and improve long-term glaucoma implant performance.

  20. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    Science.gov (United States)

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  1. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  2. [Immunologic problems in vascular homografts].

    Science.gov (United States)

    D'Addato, M; Mirelli, M

    2001-01-01

    Fresh arterial homografts are immunogenic, inducing in recipient a strong immune response specifically directed against the antigens of the donor graft. The initial immune response seems to be cellular (lymphocytotoxic) and the late reaction humoral (antibody), even if they are strictly correlated. Immunosuppressive therapy reduce the immune reaction, but this response is dose-related. Implanted arterial homografts induce a donor-specific response similar to chronic reaction, which occurs in the recipients of vascularized solid-organ allografts. Therefore, in arterial transplantation, ABO compatibility and negative crossmatch should be respected. Effort should be made to curb the immune response by prospective cross-matching, immunosuppressive therapy and preoperative manipulation of homografts to reduce their antigenicity.

  3. Vascular endoprostheses for femoro-popliteal occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Triller, J; Mahler, F; Do, D; Thalmann, R

    1989-03-01

    A self-expanding vascular endoprothesis (wall stent) was implanted in 26 patients with femoro-popliteal occlusive disease following recurrent stenosis or occlusion after percutaneous angioplasty. Implantation was successful in all cases and there were no complications. Five of the 26 patients developped a thrombosis in the first nine days; in four of these, thrombolysis was successful. Patency rate after one month was 96%, after three months 95%, after six months 85% and after nine months 87%. In order to prevent thrombosis after implantation, anticoagulant therapy is indicated. Poor distal flow encourages intimal hyperplasia and therefore recurrences.

  4. Vascular endoprostheses for femoro-popliteal occlusive disease

    International Nuclear Information System (INIS)

    Triller, J.; Mahler, F.; Do, D.; Thalmann, R.

    1989-01-01

    A self-expanding vascular endoprothesis (wall stent) was implanted in 26 patients with femoro-popliteal occlusive disease following recurrent stenosis or occlusion after percutaneous angioplasty. Implantation was successful in all cases and there were no complications. Five of the 26 patients developped a thrombosis in the first nine days; in four of these, thrombolysis was successful. Patency rate after one month was 96%, after three months 95%, after six months 85% and after nine months 87%. In order to prevent thrombosis after implantation, anticoagulant therapy is indicated. Poor distal flow encourages intimal hyperplasia and therefore recurrences. (orig.) [de

  5. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  6. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  7. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  8. Complication-related removal of totally implantable venous access port systems: Does the interval between placement and first use and the neutropenia-inducing potential of chemotherapy regimens influence their incidence? A four-year prospective study of 4045 patients.

    Science.gov (United States)

    Kakkos, A; Bresson, L; Hudry, D; Cousin, S; Lervat, C; Bogart, E; Meurant, J P; El Bedoui, S; Decanter, G; Hannebicque, K; Regis, C; Hamdani, A; Penel, N; Tresch-Bruneel, E; Narducci, F

    2017-04-01

    Totally implantable venous access port systems are widely used in oncology, with frequent complications that sometimes necessitate device removal. The aim of this study is to investigate the impact of the time interval between port placement and initiation of chemotherapy and the neutropenia-inducing potential of the chemotherapy administered upon complication-related port removal. Between January 2010 and December 2013, 4045 consecutive patients were included in this observational, single-center prospective study. The chemotherapy regimens were classified as having a low (20%) risk for inducing neutropenia. The overall removal rate due to complications was 7.2%. Among them, port-related infection (2.5%) and port expulsion (1%) were the most frequent. The interval between port insertion and its first use was shown to be a predictive factor for complication-related removal rates. A cut-off of 6 days was statistically significant (p = 0.008), as the removal rate for complications was 9.4% when this interval was 0-5 days and 5.7% when it was ≥6 days. Another factor associated with port complication rate was the neutropenia-inducing potential of the chemotherapy regimens used, with removal for complications involved in 5.5% of low-risk regimens versus 9.4% for the intermediate- and high-risk regimens (p = 0.003). An interval of 6 days between placement and first use of the port reduces the removal rate from complications. The intermediate- and high-risk for neutropenia chemotherapy regimens are related to higher port removal rates from complications than low-risk regimens. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  9. The breast implant controversy.

    Science.gov (United States)

    Cook, R R; Harrison, M C; LeVier, R R

    1994-02-01

    The breast implant issue is a "bad news/good news" story. For many women with implants, the controversy has caused a fair degree of anxiety which may or may not be resolved as further information becomes available. It has also taken its toll on Dow Corning. Whole lines of medical products have been eliminated or are being phase out. The development of new medical applications has been terminated. As a consequence, employees have lost their jobs. What the effect will be on the biomedical industry as a whole remains to be seen (11). While silicones have been an important component in various medical devices, it is likely that other materials can be used as replacements. However, suppliers of non-silicone materials are also reevaluating their role in this market. For example, Du Pont, the nation's largest chemical company, has determined that the unpredictable and excessive costs of doing business with manufacturers of implantable medical devices no longer justifies the unrestricted sale of standard raw materials into this industry. Other companies are quietly following suit. On the up side, it is possible that the research being driven by this controversy will result in a greater understanding of the immunologic implications of xenobiotics, of the importance of nonbiased observations, of the need for ready access to valid data sets, and of the opportunity for valid scientific information to guide legal decisions. Only time will tell.

  10. First-in-man intraglandular implantation of stromal vascular fraction and adipose-derived stem cells plus platelet-rich plasma in irradiation-induced gland damage: a case study

    Directory of Open Access Journals (Sweden)

    Comella K

    2017-08-01

    Full Text Available Kristin Comella,1 Walter Bell2 1US Stem Cell, Inc, Sunrise, FL, USA; 2South African Stem Cell Institute, Parys, South Africa Background: Stromal vascular fraction (SVF is a mixture of cells which can be isolated from a mini-lipoaspirate of fat tissue. Platelet-rich plasma (PRP is a mixture of growth factors and other nutrients which can be obtained from peripheral blood. Adipose-derived stem/stromal cells (ADSCs can be isolated from fat tissue and expanded in culture. The SVF includes a variety of different cells such as ADSCs, pericytes, endothelial/progenitor cells, and a mix of different growth factors. The adipocytes (fat cells can be removed via centrifugation. Here, we describe the rationale and, to our knowledge, the first clinical implementation of SVF and PRP followed by repeat dosing of culture-expanded ADSCs into a patient with severe xerostomia postirradiation. Methods: Approximately 120 mLs of adipose tissue was removed via mini-lipoaspirate procedure under local anesthetic. The SVF was prepared from half of the fat and resuspended in PRP. The mixture was delivered via ultrasound directly into the submandibular and parotid glands on both the right and left sides. The remaining 60 mLs of fat was processed to culture-expand ADSCs. The patient received seven follow-up injections of the ADSCs plus PRP at 5, 8, 16, 18, 23, 28, and 31 months postliposuction. The subject was monitored over a period of 31 months for safety (adverse events, glandular size via ultrasound and saliva production. Results: Throughout the 31-month monitoring period, no safety events such as infection or severe adverse events were reported. The patient demonstrated an increase in gland size as measured by ultrasound which corresponded to increased saliva production. Conclusion: Overall, the patient reported improved quality of life and willingness to continue treatments. The strong safety profile and preliminary efficacy results warrant larger studies to determine

  11. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  12. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  13. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... impact for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  14. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    International Nuclear Information System (INIS)

    Ruparelia, Neil; Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio; Latib, Azeem

    2015-01-01

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  15. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Neil [San Raffaele Scientific Institute, Milan (Italy); Imperial College, London (United Kingdom); Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio [San Raffaele Scientific Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [San Raffaele Scientific Institute, Milan (Italy)

    2015-09-15

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  16. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  17. Prevalence, predictors, and prognostic implications of residual impairment of functional capacity after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    M. Abdelghani (Mohammad); R. Cavalcante (Rafael); Y. Miyazaki (Yosuke); R.J. de Winter (Robbert); R. Sarmento-Leite (Rogerio); J.A. Mangione (José A.); A.C. Abizaid (Alexandre); P.A. Lemos Neto (Pedro); P.W.J.C. Serruys (Patrick); F.S. De Brito Jr. (Fabio)

    2017-01-01

    markdownabstractBackground: Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after

  18. Prevalence, predictors, and prognostic implications of residual impairment of functional capacity after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Abdelghani, Mohammad; Cavalcante, Rafael; Miyazaki, Yosuke; de Winter, Robbert J.; Sarmento-Leite, Rogério; Mangione, José A.; Abizaid, Alexandre; Lemos, Pedro A.; Serruys, Patrick W.; de Brito, Fabio S.

    2017-01-01

    Background Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after valve replacement. We

  19. Comparison of Radial Access, Guided Femoral Access, and Non-Guided Femoral Access Among Women Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Koshy, Linda M; Aberle, Laura H; Krucoff, Mitchell W; Hess, Connie N; Mazzaferri, Ernest; Jolly, Sanjit S; Jacobs, Alice; Gibson, C Michael; Mehran, Roxana; Gilchrist, Ian C; Rao, Sunil V

    2018-01-01

    This study was conducted to determine the association between radial access, guided femoral access, and non-guided femoral access on postprocedural bleeding and vascular complications after percutaneous coronary intervention (PCI). Bleeding events and major vascular complications after PCI are associated with increased morbidity, mortality, and cost. While the radial approach has been shown to be superior to the femoral approach in reducing bleeding and vascular complications, whether the use of micropuncture, fluoroscopy, or ultrasound mitigates these differences is unknown. We conducted a post hoc analysis of women in the SAFE-PCI for Women trial who underwent PCI and had the access method identified (n = 643). The primary endpoint of postprocedure bleeding or vascular complications occurring within 72 hours or at discharge was adjudicated by an independent clinical events committee and was compared based on three categories of access technique: radial, guided femoral (fluoroscopy, micropuncture, ultrasound), or non-guided femoral (none of the aforementioned). Differences between the groups were determined using multivariate logistic regression using radial access as the reference. Of the PCI population, 330 underwent radial access, 228 underwent guided femoral access, and 85 underwent non-guided femoral access. There was a statistically significant lower incidence of the primary endpoint with radial access vs non-guided femoral access; however, there was no significant difference between radial approach and femoral access guided by fluoroscopy, micropuncture, or ultrasound. This post hoc analysis demonstrates that while radial access is safer than non-guided femoral access, guided femoral access appears to be associated with similar bleeding events or vascular complications as radial access.

  20. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  1. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  2. Vascular malformations in pediatrics

    International Nuclear Information System (INIS)

    Reith, W.; Shamdeen, M.G.

    2003-01-01

    Vascular malformations are the cause of nearly all non-traumatic intracranial hemorrhage in children beyond the neonatal stage. Therefore, any child presenting with spontaneous intracranial hemorrhage should be evaluated for child abuse and for vascular malformations. Intracerebral malformations of the cerebral vasculature include vein of Galen malformations, arteriovenous malformation (AVM), cavernomas, dural arteriovenous fistulas, venous anomalies (DVA), and capillary teleangiectasies. Although a few familial vascular malformation have been reported, the majority are sporadic. Clinical symptoms, diagnostic and therapeutic options are discussed. (orig.) [de

  3. Surface characterization of titanium based dental implants; Caracterizacao de implantes odontologicos a base de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Castilho, Guilherme Augusto Alcaraz

    2006-07-01

    Dental implantology uses metallic devices made of commercially pure titanium in order to replace lost teeth. Titanium presents favorable characteristics as bio material and modern implants are capable of integrate, witch is the union between bone and implant without fibrous tissue development. Three of the major Brazilian implant manufacturers were chosen to join the study. A foreign manufacturer participated as standard. The manufacturers had three specimens of each implant with two different surface finishing, as machined and porous, submitted to analysis. Surface chemical composition and implant morphology were analyzed by X-ray photoelectron spectroscopy (XP S), scanning electron microscopy (SEM) and microprobe. Implant surface is mainly composed of titanium, oxygen and carbon. Few contaminants commonly present on implant surface were found on samples. Superficial oxide layer is basically composed of titanium dioxide (TiO{sub 2}), another oxides as Ti O and Ti{sub 2}O{sub 3} were also found in small amount. Carbon on implant surface was attributed to manufacturing process. Nitrogen, Phosphorous and Silicon appeared in smaller concentration on surface. There was no surface discrepancy among foreign and Brazilian made implants. SEM images were made on different magnification, 35 X to 3500 X, and showed similarity among as machined implants. Porous surface finishing implants presented distinct morphology. This result was attributed to differences on manufacturing process. Implant bioactivity was accessed through immersion on simulated body solution (SBF) in order to verify formation of an hydroxyapatite (HA) layer on surface. Samples were divided on three groups according to immersion time: G1 (7 days), G2 (14 days), G3 (21 days), and deep in SBF solution at 37 deg C. After being removed from solution, XPS analyses were made and then implants have been submitted to microprobe analysis. XPS showed some components of SBF solution on sample surface but microprobe

  4. Vascularized bone transplant chimerism mediated by vascular endothelial growth factor.

    Science.gov (United States)

    Willems, Wouter F; Larsen, Mikko; Friedrich, Patricia F; Bishop, Allen T

    2015-01-01

    Vascular endothelial growth factor (VEGF) induces angiogenesis and osteogenesis in bone allotransplants. We aim to determine whether bone remodeling in VEGF-treated bone allotransplants results from repopulation with circulation-derived autogenous cells or survival of allogenic transplant-derived cells. Vascularized femoral bone transplants were transplanted from female Dark Agouti rats (DA;RT1(a) ) to male Piebald Viral Glaxo (PVG;RT1(c) ). Arteriovenous bundle implantation and short-term immunosuppression were used to maintain cellular viability. VEGF was encapsulated in biodegradable microspheres and delivered intramedullary in the experimental group (n = 22). In the control group (n = 22), no VEGF was delivered. Rats were sacrificed at 4 or 18 weeks. Laser capture microdissection of bone remodeling areas was performed at the inner and outer cortex. Sex-mismatched genes were quantified with reverse transcription-polymerase chain reaction to determine the amount of male cells to total cells, defined as the relative expression ratio (rER). At 4 weeks, rER was significantly higher at the inner cortex in VEGF-treated transplants as compared to untreated transplants (0.622 ± 0.225 vs. 0.362 ± 0.081, P = 0.043). At 4 weeks, the outer cortex in the control group had a significantly higher rER (P = 0.038), whereas in the VEGF group, the inner cortex had a higher rER (P = 0.015). Over time, in the outer cortex the rER significantly increased to 0.634 ± 0.106 at 18 weeks in VEGF-treated rats (P = 0.049). At 18 weeks, the rER was >0.5 at all cortical areas in both groups. These in vivo findings suggest a chemotactic effect of intramedullary applied VEGF on recipient-derived bone and could imply that more rapid angiogenesis of vascularized allotransplants can be established with microencapsulated VEGF. © 2014 Wiley Periodicals, Inc.

  5. Improved vascularization of planar membrane diffusion devices following continuous infusion of vascular endothelial growth factor.

    Science.gov (United States)

    Trivedi, N; Steil, G M; Colton, C K; Bonner-Weir, S; Weir, G C

    2000-01-01

    Improving blood vessel formation around an immunobarrier device should improve the survival of the encapsulated tissue. In the present study we investigated the formation of new blood vessels around a planar membrane diffusion device (the Baxter Theracyte System) undergoing a continuous infusion of vascular endothelial growth factor through the membranes and into the surrounding tissue. Each device (20 microl) had both an inner immunoisolation membrane and an outer vascularizing membrane. Human recombinant vascular endothelial growth factor-165 was infused at 100 ng/day (low dose: n = 6) and 500 ng/day (high dose: n = 7) for 10 days into devices implanted s.c. in Sprague-Dawley rats; noninfused devices transplanted for an identical period were used as controls (n = 5). Two days following the termination of VEGF infusion, devices were loaded with 20 microl of Lispro insulin (1 U/kg) and the kinetics of insulin release from the lumen of the device was assessed. Devices were then explanted and the number of blood vessels (capillary and noncapillary) was quantified using morphometry. High-dose vascular endothelial growth factor infusion resulted in two- to threefold more blood vessels around the device than that obtained with the noninfused devices and devices infused with low-dose vascular endothelial growth factor. This increase in the number of blood vessels was accompanied by a modest increase in insulin diffusion from the device in the high-dose vascular endothelial growth factor infusion group. We conclude that vascular endothelial growth factor can be used to improve blood vessel formation adjacent to planar membrane diffusion devices.

  6. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  7. Double site-bond percolation model for biomaterial implants

    OpenAIRE

    Mely, H.; Mathiot, J. -F.

    2011-01-01

    9 figures - 10 pages; We present a double site-bond percolation model to account, on the one hand, for the vascularization and/or resorption of biomaterial implant in bones, and on the other hand, for its mechanical continuity. The transformation of the implant into osseous material, and the dynamical formation/destruction of this osseous material is accounted for by creation and destruction of links and sites in two, entangled, networks. We identify the relevant parameters to describe the im...

  8. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  9. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  10. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  11. Uterine Vascular Lesions

    Science.gov (United States)

    Vijayakumar, Abhishek; Srinivas, Amruthashree; Chandrashekar, Babitha Moogali; Vijayakumar, Avinash

    2013-01-01

    Vascular lesions of the uterus are rare; most reported in the literature are arteriovenous malformations (AVMs). Uterine AVMs can be congenital or acquired. In recent years, there has been an increasing number of reports of acquired vascular lesions of the uterus following pregnancy, abortion, cesarean delivery, and curettage. It can be seen from these reports that there is confusion concerning the terminology of uterine vascular lesions. There is also a lack of diagnostic criteria and management guidelines, which has led to an increased number of unnecessary invasive procedures (eg, angiography, uterine artery embolization, hysterectomy for abnormal vaginal bleeding). This article familiarizes readers with various vascular lesions of the uterus and their management. PMID:24340126

  12. Magnetic resonance vascular imaging

    International Nuclear Information System (INIS)

    Axel, L

    1989-01-01

    The basis principles of MRI are reviewed in order to understand how blood flow effects arise in conventional imaging. Then some of the ways these effects have ben used in MRI techniques specifically designed for vascular imaging, are considered. (author)

  13. The making of indigenous vascular prosthesis

    Directory of Open Access Journals (Sweden)

    Madathipat Unnikrishnan

    2016-01-01

    Full Text Available Background & objectives: Vascular illnesses are on the rise in India, due to increase in lifestyle diseases and demographic transition, requiring intervention to save life, organ or limbs using vascular prosthesis. The aim of this study was to develop indigenous large diameter vascular graft for treatment of patients with vascular pathologies. Methods: The South India Textile Research Association, at Coimbatore, Tamil Nadu, India, developed seamless woven polyester (Polyethylene terephthalate graft at its research wing. Further characterization and testing followed by clinical trials were conducted at Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India. Fifteen in vivo experiments were carried out in 1992-1994 in pigs as animal model. Controlled (phase I clinical trial in ten patients was performed along with control graft. Thereafter, phase II trial involved 22 patients who underwent multi-centre clinical trial in four centres across India. Results: Laboratory testing showed that polyester graft was non-toxic, non-leeching and non-haemolytic with preserved long-term quality, further confirming in pigs by implanting in thoracic aorta, comparable to control Dacron grafts. Perigraft incorporation and smooth neointima formation which are prime features of excellent healing characteristics, were noted at explantation at planned intervals. Subsequently in the phase I and II clinical trials, all patients had excellent recovery without mortality or device-related adverse events. Patients receiving the test graft were followed up for 10 and 5 years, respectively. Serial clinical, duplex scans and CT angiograms performed periodically confirmed excellent graft performance. Interpretation & conclusions: Indigenously developed Chitra vascular graft was comparable to commercially available Dacron graft, ready for clinical use at affordable cost to patients as against costly imported grafts.

  14. A biodegradable vascularizing membrane: a feasibility study.

    Science.gov (United States)

    Kaushiva, Anchal; Turzhitsky, Vladimir M; Darmoc, Marissa; Backman, Vadim; Ameer, Guillermo A

    2007-09-01

    Regenerative medicine and in vivo biosensor applications require the formation of mature vascular networks for long-term success. This study investigated whether biodegradable porous membranes could induce the formation of a vascularized fibrous capsule and, if so, the effect of degradation kinetics on neovascularization. Poly(l-lactic acid) (PLLA) and poly(dl-lactic-co-glycolic) acid (PLGA) membranes were created by a solvent casting/salt leaching method. Specifically, PLLA, PLGA 75:25 and PLGA 50:50 polymers were used to vary degradation kinetics. The membranes were designed to have an average 60mum pore diameter, as this pore size has been shown to be optimal for inducing blood vessel formation around nondegradable polymer materials. Membrane samples were imaged by scanning electron microscopy at several time points during in vitro degradation to assess any changes in pore structure. The in vivo performance of the membranes was assessed in Sprague-Dawley rats by measuring vascularization within the fibrous capsule that forms adjacent to implants. The vascular density within 100microm of the membranes was compared with that seen in normal tissue, and to that surrounding the commercially available vascularizing membrane TheraCyte. The hemoglobin content of tissue containing the membranes was measured by four-dimensional elastic light scattering as a novel method to assess tissue perfusion. Results from this study show that slow-degrading membranes induce greater amounts of neovascularization and a thinner fibrous capsule relative to fast degrading membranes. These results may be due both to an initially increased number of macrophages surrounding the slower degrading membranes and to the maintenance of their initial pore structure.

  15. Connections matter: channeled hydrogels to improve vascularization

    Directory of Open Access Journals (Sweden)

    Severin eMuehleder

    2014-11-01

    Full Text Available The use of cell-laden hydrogels to engineer soft tissue has been emerging within the past years. Despite several newly developed and sophisticated techniques to encapsulate different cell types the importance of vascularization of the engineered constructs is often underestimated. As a result, cell death within a construct leads to impaired function and inclusion of the implant. Here, we discuss the fabrication of hollow channels within hydrogels as a promising strategy to facilitate vascularization. Furthermore, we present an overview on the feasible use of removable spacers, 3D laser- and planar processing strategies to create channels within hydrogels. The implementation of these structures promotes control over cell distribution and increases oxygen transport and nutrient supply in vitro. However, many studies lack the use of endothelial cells in their approaches leaving out an important factor to enhance vessel ingrowth and anastomosis formation upon implantation. In addition, the adequate endothelial cell type needs to be considered to make these approaches bridge the gap to in vivo applications.

  16. Connections matter: channeled hydrogels to improve vascularization.

    Science.gov (United States)

    Muehleder, Severin; Ovsianikov, Aleksandr; Zipperle, Johannes; Redl, Heinz; Holnthoner, Wolfgang

    2014-01-01

    The use of cell-laden hydrogels to engineer soft tissue has been emerging within the past years. Despite, several newly developed and sophisticated techniques to encapsulate different cell types the importance of vascularization of the engineered constructs is often underestimated. As a result, cell death within a construct leads to impaired function and inclusion of the implant. Here, we discuss the fabrication of hollow channels within hydrogels as a promising strategy to facilitate vascularization. Furthermore, we present an overview on the feasible use of removable spacers, 3D laser-, and planar processing strategies to create channels within hydrogels. The implementation of these structures promotes control over cell distribution and increases oxygen transport and nutrient supply in vitro. However, many studies lack the use of endothelial cells in their approaches leaving out an important factor to enhance vessel ingrowth and anastomosis formation upon implantation. In addition, the adequate endothelial cell type needs to be considered to make these approaches bridge the gap to in vivo applications.

  17. Tissue response to a new type of biomaterial implanted subcutaneously in rats

    DEFF Research Database (Denmark)

    Boennelycke, Marie; Christensen, Lise; Nielsen, Lene Feldskov

    2011-01-01

    -cellular matrix (ECM) or estrogen. Methods Ten implants of each type were tested for 3 and 8 weeks, respectively. Histological assessment of connective tissue organization, inflammation, vascularization, and thickness of regenerated tissue was undertaken. Results All implants had a high degree of biocompatibility....... ECM-enriched implants had significantly higher inflammatory scores compared to pure implants at 3 weeks. At 8 weeks, neither of the parameters differed significantly. No trace of the implants remained. Conclusions The MPEG-PLGA is highly biocompatible, degrades quickly, and seems inert in the process...

  18. 可降解金属镁合金支架(MPM)植入兔腹主动脉后对血管内膜的生物学反应%The research about the biological reaction to vascular intima after the biodegradable magnesium metal stents ( MPM) implanted in the abdominal aorta of experimental rabbits

    Institute of Scientific and Technical Information of China (English)

    丁健; 王永利; 陈亮; 王征宇; 刘利珍; 陈锦琼; 彭志清; 刘强

    2017-01-01

    目的 观察新型可降解镁合金支架-MPM在兔腹主动脉降解过程中对血管内膜的影响.方法 新西兰大白兔12只,分为4组,每组3只,每只兔子腹主动脉距肾动脉水平下1cm处置入可吸收金属镁合金支架-MPM 1枚,于术后1个月(30天)、2个月(60天)、3个月(90天)及6个月(180天),分别对1组实验动物支架段血管进行病理切片,对其内膜面积、管腔面积及免疫组化PCNA阳性细胞光密度值进行统计分析.结果 1个月、2个月、3个月及6个月时支架内膜面积分别为(0.87±0.6)mm2、(0.73±0.33)mm2、(1.38±0.47)mm2、(0.85±0.23)mm2,各个时间终点剩余管腔面积分别为(2.11±0.41)mm2、(1.85±0.44)mm2、(1.38±0.31)mm2、(1.86±0.43)mm2,光镜下观察支架植入后,内膜逐渐增生,其增厚呈现出不均一性,3个月时内膜增生为著(P<0.05),管腔剩余面积与内膜增厚呈现一致性,免疫组化PCNA阳性细胞数的平均光密度值显示第3个月时为0.00917±0.0025,相比其他对照组有统计学差异(P<0.05),进一步验证了内膜增生、管腔狭窄在3个月时达到高峰,随之当支架降解完全后,增生减少,血管内膜出现正性重塑.结论 可降解镁合金支架MPM在兔主动脉降解过程中不同时间会对血管内膜产生不同程度的内膜增生反应及管腔狭窄,其中以3个月(90天)时间时为著,此后增生有逐渐减少的趋势.%Objective To observe the characteristics of vascular neointima and lumen area of MPM bioabsorbable magnesium alloy stent after being implanted in the abdominal aorta of experimental rabbits .Methods Totally, twelve new zealand white rab-bits were randomly and equally divided into 4 groups according to the postoperative time (1, 2, 3 and 6 months after stent implan-tation).Each of them were implanted a MPM absorbable magnesium alloy stent one centimeter below renal artery in abdominal a -ortas respectively , and then, stent segments of the arteries of every group were

  19. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  20. The impact of various scaffold components on vascularized bone constructs.

    Science.gov (United States)

    Eweida, Ahmad; Schulte, Matthias; Frisch, Oliver; Kneser, Ulrich; Harhaus, Leila

    2017-06-01

    Bone tissue engineering is gaining more interest in the field of craniofacial surgery where continuous efforts are being made to improve the outcomes via modulation of the scaffold components. In an in vitro three dimensional (3D) culture, the effect of bone morphogenic protein 2 (BMP2, 60 μg/ml) and the effect of different cell seeding densities (0.25, 0.5, and 1 × 104) of rat mesenchymal stem cells seeded on nanocrystalline hydroxyapatite in silica gel matrix (Nanobone ® ) on the cell viability and differentiation were studied. Alkaline phosphatase and viability assays were performed at day 7, day 14, and day 21 to assess the differentiation and the relative fraction of viable cells in the 3D cell cultures. In a subsequent in vivo study, we examined the effect of axial vascularization, the scaffold's particle size and the nature of the matrix (collagen type I vs. diluted fibrin) on vascularization and tissue generation in vascularized bone construct in rats. Regarding vascularization, we compared constructs vascularized randomly by extrinsic vascularization from the periphery of the implanted construct with others vascularized axially via an implanted arteriovenous loop (AVL). Regarding the particle size, we compared constructs having a scaffold particle size of 0.2 mm (powder) with other constructs having a particle size of 2 × 0.6 mm (granules). Regarding the matrix we compared constructs having a collagen matrix with others having a fibrin matrix. Various groups were compared regarding the amount of tissue generation, vascularization, and cellular proliferation. The initial seeding density had a temporary and minimal effect on the overall osteogenic differentiation of the cells. On the contrary, adding BMP2 in a concentration of 60 μg/ml over one week led to an overall enhanced osteogenic differentiation despite depressed cell viability. Axial vascularization was mandatory for efficient tissue formation and vascularization of the bone construct

  1. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  2. Design Approaches to Myocardial and Vascular Tissue Engineering.

    Science.gov (United States)

    Akintewe, Olukemi O; Roberts, Erin G; Rim, Nae-Gyune; Ferguson, Michael A H; Wong, Joyce Y

    2017-06-21

    Engineered tissues represent an increasingly promising therapeutic approach for correcting structural defects and promoting tissue regeneration in cardiovascular diseases. One of the challenges associated with this approach has been the necessity for the replacement tissue to promote sufficient vascularization to maintain functionality after implantation. This review highlights a number of promising prevascularization design approaches for introducing vasculature into engineered tissues. Although we focus on encouraging blood vessel formation within myocardial implants, we also discuss techniques developed for other tissues that could eventually become relevant to engineered cardiac tissues. Because the ultimate solution to engineered tissue vascularization will require collaboration between wide-ranging disciplines such as developmental biology, tissue engineering, and computational modeling, we explore contributions from each field.

  3. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  4. Overview of vascular disease

    International Nuclear Information System (INIS)

    Bisset, G.S. III

    1998-01-01

    Vascular disease in the pediatric population is a poorly understood process which is often underestimated in its incidence. The common beginnings of such ubiquitous diseases as atherosclerosis manifest themselves at a cellular level shortly after birth. Other common systemic disorders, including congestive heart failure and sepsis, are also intricately associated with dysfunctional vasculature. Progress in the understanding of normal and pathophysiologic processes within the vascular system begins with the 'control center' - the endothelial cell. The purpose of this review is to consolidate a body of knowledge on the processes that occur at the cellular level within the blood vessel wall, and to simplify the understanding of how imbalances in these physiologic parameters result in vascular disease. (orig.)

  5. PAIN RELIEF MEDIATED BY IMPLANTABLE DRUG-DELIVERY DEVICES

    NARCIS (Netherlands)

    HOEKSTRA, A

    Various totally implantable drug delivery systems from single access ports to micropumps are now available for administration of repeated boluses, and continuous or programmable infusions. In this respect, emphasis is given to a relatively cheap, totally implantable system for self-administering

  6. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  7. Broadband Access

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Broadband Access. Worldwide market for broadband access $30 Billion! Over 200 million broadband subscribers worldwide! Various Competing Broadband access. Digital Subscriber line; Wireless; Optical Fiber.

  8. In vivo analysis of biocompatibility and vascularization of the synthetic bone grafting substitute NanoBone.

    Science.gov (United States)

    Abshagen, K; Schrodi, I; Gerber, T; Vollmar, B

    2009-11-01

    One of the major challenges in the application of bone substitutes is adequate vascularization and biocompatibility of the implant. Thus, the temporal course of neovascularization and the microvascular inflammatory response of implants of NanoBone (fully synthetic nanocrystalline bone grafting material) were studied in vivo by using the mouse dorsal skinfold chamber model. Angiogenesis, microhemodynamics, and leukocyte-endothelial cell interaction were analyzed repetitively after implantation in the center and in the border zone of the implant up to 15 days. Both NanoBone granules and plates exhibited high biocompatibility comparable to that of cancellous bone, as indicated by a lack of venular leukocyte activation after implantation. In both synthetic NanoBone groups, signs of angiogenesis could be observed even at day 5 after implantation, whereas granules showed higher functional vessel density compared with NanoBone plates. The angiogenic response of the cancellous bone was markedly accelerated in the center of the implant tissue. Histologically, implant tissue showed an ingrowth of vascularized fibrous tissue into the material combined with an increased number of foreign-body giant cells. In conclusion, NanoBone, particularly in granular form, showed high biocompatibility and high angiogenic response, thus improving the healing of bone defects. Our results underline that, beside the composition and nanostructure, the macrostructure is also of importance for the incorporation of the biomaterial by the host tissue. (c) 2008 Wiley Periodicals, Inc.

  9. Acceleration of vascularized bone tissue-engineered constructs in a large animal model combining intrinsic and extrinsic vascularization.

    Science.gov (United States)

    Weigand, Annika; Beier, Justus P; Hess, Andreas; Gerber, Thomas; Arkudas, Andreas; Horch, Raymund E; Boos, Anja M

    2015-05-01

    During the last decades, a range of excellent and promising strategies in Bone Tissue Engineering have been developed. However, the remaining major problem is the lack of vascularization. In this study, extrinsic and intrinsic vascularization strategies were combined for acceleration of vascularization. For optimal biomechanical stability of the defect site and simplifying future transition into clinical application, a primary stable and approved nanostructured bone substitute in clinically relevant size was used. An arteriovenous (AV) loop was microsurgically created in sheep and implanted, together with the bone substitute, in either perforated titanium chambers (intrinsic/extrinsic) for different time intervals of up to 18 weeks or isolated Teflon(®) chambers (intrinsic) for 18 weeks. Over time, magnetic resonance imaging and micro-computed tomography (CT) analyses illustrate the dense vascularization arising from the AV loop. The bone substitute was completely interspersed with newly formed tissue after 12 weeks of intrinsic/extrinsic vascularization and after 18 weeks of intrinsic/extrinsic and intrinsic vascularization. Successful matrix change from an inorganic to an organic scaffold could be demonstrated in vascularized areas with scanning electron microscopy and energy dispersive X-ray spectroscopy. Using the intrinsic vascularization method only, the degradation of the scaffold and osteoclastic activity was significantly lower after 18 weeks, compared with 12 and 18 weeks in the combined intrinsic-extrinsic model. Immunohistochemical staining revealed an increase in bone tissue formation over time, without a difference between intrinsic/extrinsic and intrinsic vascularization after 18 weeks. This study presents the combination of extrinsic and intrinsic vascularization strategies for the generation of an axially vascularized bone substitute in clinically relevant size using a large animal model. The additional extrinsic vascularization promotes tissue

  10. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  11. Nano- and microstructured materials for in vitro studies of the physiology of vascular cells

    OpenAIRE

    Alexandra M. Greiner; Adria Sales; Hao Chen; Sarah A. Biela; Dieter Kaufmann; Ralf Kemkemer

    2016-01-01

    The extracellular environment of vascular cells in vivo is complex in its chemical composition, physical properties, and architecture. Consequently, it has been a great challenge to study vascular cell responses in vitro, either to understand their interaction with their native environment or to investigate their interaction with artificial structures such as implant surfaces. New procedures and techniques from materials science to fabricate bio-scaffolds and surfaces have enabled novel studi...

  12. Renal posttransplant's vascular complications

    Directory of Open Access Journals (Sweden)

    Bašić Dragoslav

    2003-01-01

    Full Text Available INTRODUCTION Despite high graft and recipient survival figures worldwide today, a variety of technical complications can threaten the transplant in the postoperative period. Vascular complications are commonly related to technical problems in establishing vascular continuity or to damage that occurs during donor nephrectomy or preservation [13]. AIM The aim of the presenting study is to evaluate counts and rates of vascular complications after renal transplantation and to compare the outcome by donor type. MATERIAL AND METHODS A total of 463 kidneys (319 from living related donor LD and 144 from cadaveric donor - CD were transplanted during the period between June 1975 and December 1998 at the Urology & Nephrology Institute of Clinical Centre of Serbia in Belgrade. Average recipients' age was 33.7 years (15-54 in LD group and 39.8 (19-62 in CD group. Retrospectively, we analyzed medical records of all recipients. Statistical analysis is estimated using Hi-squared test and Fischer's test of exact probability. RESULTS Major vascular complications including vascular anastomosis thrombosis, internal iliac artery stenosis, internal iliac artery rupture obliterant vasculitis and external iliac vein rupture were analyzed. In 25 recipients (5.4% some of major vascular complications were detected. Among these cases, 22 of them were from CD group vs. three from LD group. Relative rate of these complications was higher in CD group vs. LD group (p<0.0001. Among these complications dominant one was vascular anastomosis thrombosis which occurred in 18 recipients (17 from CD vs. one from LD. Of these recipients 16 from CD lost the graft, while the rest of two (one from each group had lethal outcome. DISCUSSION Thrombosis of renal allograft vascular anastomosis site is the most severe complication following renal transplantation. In the literature, renal allograft thrombosis is reported with different incidence rates, from 0.5-4% [14, 15, 16]. Data from the

  13. Initial evaluation of vascular ingrowth into superporous hydrogels.

    Science.gov (United States)

    Keskar, Vandana; Gandhi, Milind; Gemeinhart, Ernest J; Gemeinhart, Richard A

    2009-08-01

    There is a need for new materials and architectures for tissue engineering and regenerative medicine. Based upon our recent results developing novel scaffold architecture, we hypothesized that this new architecture would foster vascularization, a particular need for tissue engineering. We report on the potential of superporous hydrogel (SPH) scaffolds for in vivo cellular infiltration and vascularization. Poly(ethylene glycol) diacrylate (PEGDA) SPH scaffolds were implanted in the dorsum of severe combined immunodeficient (SCID) mice and harvested after 4 weeks of in vivo implantation. The SPHs were visibly red and vascularized, as apparent when compared to the non-porous hydrogel controls, which were macroscopically avascular. Host cell infiltration was observed throughout the SPHs. Blood cells and vascular structures, confirmed through staining for CD34 and smooth muscle alpha-actin, were observed throughout the scaffolds. This novel soft material may be utilized for cell transplantation, tissue engineering and in combination with cell therapies. The neovasularization and limited fibrotic response suggest that the architecture may be conducive to cell survival and rapid vessel development.

  14. Brainjacking: Implant Security Issues in Invasive Neuromodulation.

    Science.gov (United States)

    Pycroft, Laurie; Boccard, Sandra G; Owen, Sarah L F; Stein, John F; Fitzgerald, James J; Green, Alexander L; Aziz, Tipu Z

    2016-08-01

    The security of medical devices is critical to good patient care, especially when the devices are implanted. In light of recent developments in information security, there is reason to be concerned that medical implants are vulnerable to attack. The ability of attackers to exert malicious control over brain implants ("brainjacking") has unique challenges that we address in this review, with particular focus on deep brain stimulation implants. To illustrate the potential severity of this risk, we identify several mechanisms through which attackers could manipulate patients if unauthorized access to an implant can be achieved. These include blind attacks in which the attacker requires no patient-specific knowledge and targeted attacks that require patient-specific information. Blind attacks include cessation of stimulation, draining implant batteries, inducing tissue damage, and information theft. Targeted attacks include impairment of motor function, alteration of impulse control, modification of emotions or affect, induction of pain, and modulation of the reward system. We also discuss the limitations inherent in designing implants and the trade-offs that must be made to balance device security with battery life and practicality. We conclude that researchers, clinicians, manufacturers, and regulatory bodies should cooperate to minimize the risk posed by brainjacking. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Unplanned Start on Peritoneal Dialysis Right after PD Catheter Implantation for Older People with End-Stage Renal Disease.

    Science.gov (United States)

    Povlsen, Johan V; Sørensen, Anette Bagger; Ivarsen, Per

    2015-11-01

    Unplanned start on dialysis remains a major problem for the dialysis community worldwide. Late-referred patients with end-stage renal disease (ESRD) and urgent need for dialysis are overrepresented among older people. These patients are particularly likely to be started on in-center hemodialysis (HD), with a temporary vascular access known to be associated with excess mortality and increased risks of potentially lethal complications such as bacteremia and central venous thrombosis or stenosis.The present paper describes in detail our program for unplanned start on automated peritoneal dialysis (APD) right after PD catheter implantation and summarizes our experiences with the program so far. Compared with planned start on PD after at least 2 weeks of break-in between PD catheter implantation and initiation of dialysis, unplanned start may be associated with a slight increased risk of mechanical complications but apparently no detrimental effect on mortality, peritonitis-free survival, or PD technique survival.In our opinion and experience, the risk of serious complications associated with the implantation and immediate use of a PD catheter is less than the risk of complications associated with unplanned start on HD with a temporary central venous catheter (CVC). Unplanned start on APD is a gentle, safe, and feasible alternative to unplanned start on HD with a temporary CVC that is also valid for the late-referred older patient with ESRD and urgent need for dialysis. Copyright © 2015 International Society for Peritoneal Dialysis.

  16. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  17. A systematic review of functional outcome and quality of life following reconstruction of maxillofacial defects using vascularized free fibula flaps and dental rehabilitation reveals poor data quality

    NARCIS (Netherlands)

    Wijbenga, Johan G.; Schepers, Rutger H.; Werker, Paul M. N.; Witjes, Max J. H.; Dijkstra, Pieter U.

    Background: Reconstruction and oral rehabilitation of segmental maxillofacial defects resulting from ablative surgery is commonly achieved by osteocutaneous vascularized free fibula (VFFF) transplantation combined with implant-supported dental prostheses. We systematically reviewed the literature

  18. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    Science.gov (United States)

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (Pnew implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  19. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  20. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  1. Implante transcateter de valva aórtica: resultados atuais do desenvolvimento e implante de um nova prótese brasileira Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2011-09-01

    . Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment. METHODS: Thirty-three high risk patients underwent transcatheter balloon expandable aortic valve implantation. Mean Logistic EuroScore risk was 39.30% and STS score 30.28%. Eight patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis were implanted trough the ventricular apex under rapid ventricular pacing or hemorrhagic shock. Echocardiographic and angiographic controls were performed. RESULTS: Implant was feasible in 30 cases. Three conversions occured. There was only one case of operative death. Median transvalvular aortic gradient reduced from 43.58 mmHg to 10.54 mmHg. Left ventricular function improved in the first 7 postoperative days. Paravalvular aortic regurgitation was mild and present in 30.30%. One case presented major vascular complication and another one permanent pacemaker implant. One major stroke case occurred. Overall 30-day mortality was 18.18%. CONCLUSION: The transapical implantation of catheter mounted bioprosthesis is a safe procedure with acceptable midterm results. Long term follow-up with increased sample power is mandatory in order to access hemodynamic, life quality and survival

  2. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  3. Major Vascular Neurocognitive Disorder: A Reappraisal to Vascular Dementia

    Directory of Open Access Journals (Sweden)

    Emre Kumral

    2017-03-01

    Full Text Available Major vascular neurocognitive disorder (NCD is the second leading form of dementia after Alzheimer’s disease, accounting for 17-20% of all dementias. Vascular NCD is a progressive disease caused by reduced cerebral blood flow related to multiple large volume or lacunar infarcts that induce a sudden onset and stepwise decline in cognitive abilities. Despite its prevalence and clinical importance, there is still controversy in the terminology of vascular NCD. Only after the release of Diagnostic and Statistical Manual of Mental Disorders-5 (DSM-5 (2013 did the American Psychiatric Association define vascular dementia as “major vascular NCD”. This review includes an overview of risk factors, pathophysiology, types, diagnostic and clinical features of major vascular NCD, and current treatment options of vascular NCD regarding to DSM-5 criteria

  4. Sex differences in the outcomes of stent implantation in mini-swine model.

    Science.gov (United States)

    Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R

    2018-01-01

    Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.

  5. Cell sheet engineering using the stromal vascular fraction of adipose tissue as a vascularization strategy.

    Science.gov (United States)

    Costa, Marina; Cerqueira, Mariana T; Santos, Tírcia C; Sampaio-Marques, Belém; Ludovico, Paula; Marques, Alexandra P; Pirraco, Rogério P; Reis, Rui L

    2017-06-01

    Current vascularization strategies for Tissue Engineering constructs, in particular cell sheet-based, are limited by time-consuming and expensive endothelial cell isolation and/or by the complexity of using extrinsic growth factors. Herein, we propose an alternative strategy using angiogenic cell sheets (CS) obtained from the stromal vascular fraction (SVF) of adipose tissue that can be incorporated into more complex constructs. Cells from the SVF were cultured in normoxic and hypoxic conditions for up to 8days in the absence of extrinsic growth factors. Immunocytochemistry against CD31 and CD146 revealed spontaneous organization in capillary-like structures, more complex after hypoxic conditioning. Inhibition of HIF-1α pathway hindered capillary-like structure formation in SVF cells cultured in hypoxia, suggesting a role of HIF-1α. Moreover, hypoxic SVF cells showed a trend for increased secretion of angiogenic factors, which was reflected in increased network formation by endothelial cells cultured on matrigel using that conditioned medium. In vivo implantation of SVF CS in a mouse hind limb ischemia model revealed that hypoxia-conditioned CS led to improved restoration of blood flow. Both in vitro and in vivo data suggest that SVF CS can be used as simple and cost-efficient tools to promote functional vascularization of TE constructs. Neovascularization after implantation is a major obstacle for producing clinically viable cell sheet-based tissue engineered constructs. Strategies using endothelial cells and extrinsic angiogenic growth factors are expensive and time consuming and may raise concerns of tumorigenicity. In this manuscript, we describe a simplified approach using angiogenic cell sheets fabricated from the stromal vascular fraction of adipose tissue. The strong angiogenic behavior of these cell sheets, achieved without the use of external growth factors, was further stimulated by low oxygen culture. When implanted in an in vivo model of hind limb

  6. Mini tunelizador moldável: um avanço técnico no acesso vascular para hemodiálise Mini moldable tunneler: a technical improvement for hemodialysis access

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2011-12-01

    cirurgias de confecção de fístula para hemodiálise. Sua versatilidade e baixo custo de produção podem levá-lo a substituir os tunelizadores rígidos utilizados na atualidade e apontam para estudos mais elaborados e com casuística adequada para avaliação do real valor do novo instrumento.BACKGROUND: Hemodialysis access fistula may involve creation of a tunnel for the accommodation of autologous vein or synthetic graft. The route and extent depend on the location of the anastomosis and fistula body.Currently, the tunnelers used are rigid metallic cylindrical structures. Various sizes and conformations may be necessary. OBJECTIVE: Testing the use of a mini universal moldable tunnel maker in hemodialysis access fistula surgical creation. METHODS: This is a pilot study. The tunneler developed consists of a cylindrical structure composed of stainless steel wire with a handle at the proximal end and dual interchangeable conical tip at the distal end. It is covered with a cylindrical sheath of polyethylene. Its technical surgical application and complications were studied during ten hemodialysis fistula creation. RESULTS: Characteristics of flexibility and conformability made possible the same mini tunnel maker to be used in various types of fistulas performed. The tapered distal tip with double diameter, interchangeable head, allowed the same apparatus to be used in autogenos and graft fistulas surgical creation. CONCLUSION: The same mini malleable tunneler was used in all fistulas, regardless of the site of anastomosis and type of fistula performed without complications and with excellent patency rate.

  7. Evaluation of Functionalized Porous Titanium Implants for Enhancing Angiogenesis in Vitro

    Directory of Open Access Journals (Sweden)

    Laura Roland

    2016-04-01

    Full Text Available Implant constructs supporting angiogenesis are favorable for treating critically-sized bone defects, as ingrowth of capillaries towards the center of large defects is often insufficient. Consequently, the insufficient nutritional supply of these regions leads to impaired bone healing. Implants with specially designed angiogenic supporting geometry and functionalized with proangiogenic cytokines can enhance angiogenesis. In this study, Vascular Endothelial Growth Factor (VEGF and High Mobility Group Box 1 (HMGB1 were used for incorporation into poly-ε-caprolactone (PCL-coated porous titanium implants. Bioactivity of released factors and influence on angiogenesis of functionalized implants were evaluated using a migration assay and angiogenesis assays. Both implants released angiogenic factors, inducing migration of endothelial cells. Also, VEGF-functionalized PCL-coated titanium implants enhanced angiogenesis in vitro. Both factors were rapidly released in high doses from the implant coating during the first 72 h.

  8. Plant Vascular Biology 2010

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Biao

    2014-11-17

    This grant supported the Second International Conference on Plant Vascular Biology (PVB 2010) held July 24-28, 2010 on the campus of Ohio State University, Columbus, Ohio. Biao Ding (Ohio State University; OSU) and David Hannapel (Iowa State University; ISU) served as co-chairs of this conference. Biao Ding served as the local organizer. PVB is defined broadly here to include studies on the biogenesis, structure and function of transport systems in plants, under conditions of normal plant growth and development as well as of plant interactions with pathogens. The transport systems cover broadly the xylem, phloem, plasmodesmata and vascular cell membranes. The PVB concept has emerged in recent years to emphasize the integrative nature of the transport systems and approaches to investigate them.

  9. Vascular cognitive impairment

    Directory of Open Access Journals (Sweden)

    N.V. Vakhnina

    2014-01-01

    Full Text Available Vascular pathology of the brain is the second most common cause of cognitive impairment after Alzheimer's disease. The article describes the modern concepts of etiology, pathogenetic mechanisms, clinical features and approaches to diagnosis and therapy of vascular cognitive impairment (VCI. Cerebrovascular accident, chronic cerebral circulatory insufficiency and their combination, sometimes in combination with a concomitant neurodegenerative process, are shown to be the major types of brain lesions leading to VCI. The clinical presentation of VCI is characterized by the neuropsychological status dominated by impairment of the executive frontal functions (planning, control, attention in combination with focal neurological symptoms. The diagnosis is based on comparing of the revealed neuropsychological and neurological features with neuroimaging data. Neurometabolic, acetylcholinergic, glutamatergic, and other vasoactive drugs and non-pharmacological methods are widely used to treat VCI. 

  10. Vascular Surgery and Robotics

    Directory of Open Access Journals (Sweden)

    Indrani Sen

    2016-01-01

    Full Text Available The application of robotics to Vascular surgery has not progressed as rapidly as of endovascular technology, but this is changing with the amalgamation of these two fields. The advent of Endovascular robotics is an exciting field which overcomes many of the limitations of endovascular therapy like vessel tortuosity and operator fatigue. This has much clinical appeal for the surgeon and hold significant promise of better patient outcomes. As with most newer technological advances, it is still limited by cost and availability. However, this field has seen some rapid progress in the last decade with the technology moving into the clinical realm. This review details the development of robotics, applications, outcomes, advantages, disadvantages and current advances focussing on Vascular and Endovascular robotics

  11. Susceptibility of metallic magnesium implants to bacterial biofilm infections.

    Science.gov (United States)

    Rahim, Muhammad Imran; Rohde, Manfred; Rais, Bushra; Seitz, Jan-Marten; Mueller, Peter P

    2016-06-01

    Magnesium alloys have promising mechanical and biological properties as biodegradable medical implant materials for temporary applications during bone healing or as vascular stents. Whereas conventional implants are prone to colonization by treatment resistant microbial biofilms in which bacteria are embedded in a protective matrix, magnesium alloys have been reported to act antibacterial in vitro. To permit a basic assessment of antibacterial properties of implant materials in vivo an economic but robust animal model was established. Subcutaneous magnesium implants were inoculated with bacteria in a mouse model. Contrary to the expectations, bacterial activity was enhanced and prolonged in the presence of magnesium implants. Systemic antibiotic treatments were remarkably ineffective, which is a typical property of bacterial biofilms. Biofilm formation was further supported by electron microscopic analyses that revealed highly dense bacterial populations and evidence for the presence of extracellular matrix material. Bacterial agglomerates could be detected not only on the implant surface but also at a limited distance in the peri-implant tissue. Therefore, precautions may be necessary to minimize risks of metallic magnesium-containing implants in prospective clinical applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1489-1499, 2016. © 2016 Wiley Periodicals, Inc.

  12. Vascular lesions following radiation

    International Nuclear Information System (INIS)

    Fajardo, L.F.; Berthrong, M.

    1988-01-01

    The special radiation sensitivity of the vascular system is mainly linked to that of endothelial cells, which are perhaps the most radiation-vulnerable elements of mesenchymal tissues. Within the vascular tree, radiation injures most often capillaries, sinusoids, and small arteries, in that order. Lesions of veins are observed less often, but in certain tissues the veins are regularly damaged (e.g., intestine) or are the most affected structures (i.e., liver). Large arteries do suffer the least; however, when significant damage does occur in an elastic artery (e.g., thrombosis or rupture), it tends to be clinically significant and even fatal. Although not always demonstrable in human tissues, radiation vasculopathy generally is dose and time dependent. Like other radiation-induced lesions, the morphology in the vessels is not specific, but it is characteristic enough to be often recognizable. Vascular injury, especially by therapeutic radiation is not just a morphologic marker. It is a mediator of tissue damage; perhaps the most consistent pathogenetic mechanism in delayed radiation injury

  13. Vascular lumen formation.

    Science.gov (United States)

    Lammert, Eckhard; Axnick, Jennifer

    2012-04-01

    The vascular system developed early in evolution. It is required in large multicellular organisms for the transport of nutrients, oxygen, and waste products to and from tissues. The vascular system is composed of hollow tubes, which have a high level of complexity in vertebrates. Vasculogenesis describes the de novo formation of blood vessels, e.g., aorta formation in vertebrate embryogenesis. In contrast, angiogenesis is the formation of blood vessels from preexisting ones, e.g., sprouting of intersomitic blood vessels from the aorta. Importantly, the lumen of all blood vessels in vertebrates is lined and formed by endothelial cells. In both vasculogenesis and angiogenesis, lumen formation takes place in a cord of endothelial cells. It involves a complex molecular mechanism composed of endothelial cell repulsion at the cell-cell contacts within the endothelial cell cords, junctional rearrangement, and endothelial cell shape change. As the vascular system also participates in the course of many diseases, such as cancer, stroke, and myocardial infarction, it is important to understand and make use of the molecular mechanisms of blood vessel formation to better understand and manipulate the pathomechanisms involved.

  14. Pulmonary vascular imaging

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Shure, D.

    1987-01-01

    A wide range of pulmonary vascular imaging techniques are available for the diagnostic evaluation of patients with suspected pulmonary vascular disease. The characteristics of any ideal technique would include high sensitivity and specificity, safety, simplicity, and sequential applicability. To date, no single technique meets these ideal characteristics. Conventional pulmonary angiography remains the gold standard for the diagnosis of acute thromboembolic disease despite the introduction of newer techniques such as digital subtraction angiography and magnetic resonance imaging. Improved noninvasive lower extremity venous testing methods, particularly impedance plethysmography, and ventilation-perfusion scanning can play significant roles in the noninvasive diagnosis of acute pulmonary emboli when properly applied. Ventilation-perfusion scanning may also be useful as a screening test to differentiate possible primary pulmonary hypertension from chronic thromboembolic pulmonary hypertension. And, finally, angioscopy may be a useful adjunctive technique to detect chronic thromboembolic disease and determine operability. Optimal clinical decision-making, however, will continue to require the proper interpretation of adjunctive information obtained from the less-invasive techniques, applied with an understanding of the natural history of the various forms of pulmonary vascular disease and with a knowledge of the capabilities and shortcomings of the individual techniques

  15. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  16. Wireless Access

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Wireless Access. Wireless connect to the Base station. Easy and Convenient access. Costlier as compared to the wired technology. Reliability challenges. We see it as a complementary technology to the DSL.

  17. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  18. Wnt5a Regulates the Assembly of Human Adipose Derived Stromal Vascular Fraction-Derived Microvasculatures.

    Directory of Open Access Journals (Sweden)

    Venkat M Ramakrishnan

    Full Text Available Human adipose-derived stromal vascular fraction (hSVF cells are an easily accessible, heterogeneous cell system that can spontaneously self-assemble into functional microvasculatures in vivo. However, the mechanisms underlying vascular self-assembly and maturation are poorly understood, therefore we utilized an in vitro model to identify potential in vivo regulatory mechanisms. We utilized passage one (P1 hSVF because of the rapid UEA1+ endothelium (EC loss at even P2 culture. We exposed hSVF cells to a battery of angiogenesis inhibitors and found that the pan-Wnt inhibitor IWP2 produced the most significant hSVF-EC networking decrease (~25%. To determine which Wnt isoform(s and receptor(s may be involved, hSVF was screened by PCR for isoforms associated with angiogenesis, with only WNT5A and its receptor, FZD4, being expressed for all time points observed. Immunocytochemistry confirmed Wnt5a protein expression by hSVF. To see if Wnt5a alone could restore IWP2-induced EC network inhibition, recombinant human Wnt5a (0-150 ng/ml was added to IWP2-treated cultures. The addition of rhWnt5a significantly increased EC network area and significantly decreased the ratio of total EC network length to EC network area compared to untreated controls. To determine if Wnt5a mediates in vivo microvascular self-assembly, 3D hSVF constructs containing an IgG isotype control, anti-Wnt5a neutralizing antibody or rhWnt5a were implanted subcutaneously for 2w in immune compromised mice. Compared to IgG controls, anti-Wnt5a treatment significantly reduced vessel length density by ~41%, while rhWnt5a significantly increased vessel length density by ~62%. However, anti-Wnt5a or rhWnt5a did not significantly affect the density of segments and nodes, both of which measure vascular complexity. Taken together, this data demonstrates that endogenous Wnt5a produced by hSVF plays a regulatory role in microvascular self-assembly in vivo. These findings also suggest that

  19. Open access

    NARCIS (Netherlands)

    Valkenburg, P.M.

    2015-01-01

    Open access week Van 19 tot en met 25 oktober 2015 vond wereldwijd de Open Access Week plaats. Tijdens deze week werden er over de hele wereld evenementen georganiseerd waar open access een rol speelt. Ook in Nederland zijn er diverse symposia, workshops en debatten georganiseerd zoals het debat in

  20. Implante coclear via fossa craniana média: uma nova técnica para acesso ao giro basal da cóclea Cochlear implantation through the middle cranial fossa: a novel approach to access the basal turn of the cochlea

    Directory of Open Access Journals (Sweden)

    Aline Gomes Bittencourt

    2013-04-01

    Full Text Available A técnica clássica para o implante coclear é realizada através de mastoidectomia e timpanotomia posterior. A abordagem pela fossa craniana média provou ser uma alternativa valiosa, embora venha sendo usada para o implante coclear apenas esporadicamente e sem normatização. OBJETIVO: Descrever uma nova abordagem para expor o giro basal da cóclea para o implante coclear através da fossa craniana média. MÉTODO: Cinquenta ossos temporais foram dissecados. A cocleostomia foi realizada através de uma abordagem via fossa craniana média, na parte mais superficial do giro basal da cóclea, usando o plano meatal e seio petroso superior como pontos de reparo. A parede lateral do meato acústico interno foi dissecada após o broqueamento e esqueletização do ápice petroso. A parede dissecada do meato acústico interno foi acompanhada longitudinalmente até a cocleostomia. Design: Estudo anatômico de osso temporal. RESULTADOS: Em todos os ossos temporais, apenas a parte superficial do giro basal da cóclea foi aberta. A exposição do giro basal da cóclea permitiu que as escalas timpânica e vestibular fossem visualizadas. Assim, não houve dificuldade na inserção do feixe de eletrodos através da escala timpânica. CONCLUSÃO: A técnica proposta é simples e permite exposição suficiente do giro basal da cóclea.The classic approach for cochlear implant surgery includes mastoidectomy and posterior tympanotomy. The middle cranial fossa approach is a proven alternative, but it has been used only sporadically and inconsistently in cochlear implantation. OBJECTIVE: To describe a new approach to expose the basal turn of the cochlea in cochlear implant surgery through the middle cranial fossa. METHOD: Fifty temporal bones were dissected in this anatomic study of the temporal bone. Cochleostomies were performed through the middle cranial fossa approach in the most superficial portion of the basal turn of the cochlea, using the meatal plane and

  1. Cell lineage in vascularized bone transplantation.

    Science.gov (United States)

    Willems, Wouter F; Larsen, Mikko; Friedrich, Patricia F; Bishop, Allen T

    2014-01-01

    The biology behind vascularized bone allotransplantation remains largely unknown. We aim to study cell traffic between donor and recipient following bone auto-, and allografting. Vascularized femoral transplantation was performed with arteriovenous bundle implantation and short-term immunosuppression. Twenty male Piebald Virol Glaxo (PVG; RT1(c) ) rats received isotransplants from female PVG (RT1(c) ) rats and 22 male PVG rats received allografts from female Dark Agouti rats (DA, RT1(a) ), representing a major histocompatibility mismatch. Both groups were randomly analyzed at 4 or 18 weeks. Bone remodeling areas (inner and outer cortical samples) were labeled and laser capture microdissected. Analysis of sex-mismatch genes by real-time reverse transcription-polymerase chain reaction provided the relative Expression Ratio (rER) of donor (female) to recipient (male) cells. The rER was 0.456 ± 0.266 at 4 weeks and 0.749 ± 0.387 at 18 weeks (p = 0.09) in allotransplants. In isotransplants, the rER was 0.412 ± 0.239 and 0.467 ± 0.252 at 4 and 18 weeks, respectively (p = 0.21). At 4 weeks, the rER at the outer cortical area of isotransplants was significantly lower in isotransplants as compared with allotransplants (0.247 ± 0.181 vs. 0.549 ± 0.184, p = 0.007). Cells in the inner and outer cortical bone remodeling areas in isotransplants were mainly donor derived (rER 0.5) at 18 weeks. Applying novel methodology, we describe detailed cell traffic in vascularized bone transplants, elaborating our comprehension on bone transplantation. Copyright © 2013 Wiley Periodicals, Inc.

  2. Prefabrication of axial vascularized tissue engineering coral bone by an arteriovenous loop: A better model

    International Nuclear Information System (INIS)

    Dong Qingshan; Shang Hongtao; Wu Wei; Chen Fulin; Zhang Junrui; Guo Jiaping; Mao Tianqiu

    2012-01-01

    The most important problem for the survival of thick 3-dimensional tissues is the lack of vascularization in the context of bone tissue engineering. In this study, a modified arteriovenous loop (AVL) was developed to prefabricate an axial vascularized tissue engineering coral bone in rabbit, with comparison of the arteriovenous bundle (AVB) model. An arteriovenous fistula between rabbit femoral artery and vein was anastomosed to form an AVL. It was placed in a circular side groove of the coral block. The complex was wrapped with an expanded-polytetrafluoroethylene membrane and implanted beneath inguinal skin. After 2, 4, 6 and 8 weeks, the degree of vascularization was evaluated by India ink perfusion, histological examination, vascular casts, and scanning electron microscopy images of vascular endangium. Newly formed fibrous tissues and vasculature extended over the surfaces and invaded the interspaces of entire coral block. The new blood vessels robustly sprouted from the AVL. Those invaginated cavities in the vascular endangium from scanning electron microscopy indicated vessel's sprouted pores. Above indexes in AVL model are all superior to that in AVB model, indicating that the modified AVL model could more effectively develop vascularization in larger tissue engineering bone. - Highlights: ► A modified arteriovenous loop (AVL) model in rabbit was developed in this study. ► Axial prevascularization was induced in a larger coral block by using the AVL. ► The prefabrication of axial vascularized coral bone is superior as vascular carrier.

  3. Tailoring the foreign body response for in situ vascular tissue engineering

    NARCIS (Netherlands)

    Rothuizen, T.C.; Damanik, Febriyani; Anderson, J.; Lavrijsen, T.; Cox, M.A.J.; Rabelink, T.J.; Moroni, Lorenzo; Rotmans, J.

    2015-01-01

    This study describes a screening platform for a guided in situ vascular tissue engineering approach. Polymer rods were developed that upon 3 weeks of subcutaneous implantation evoke a controlled inflammatory response culminating in encapsulation by a tube-shaped autologous fibrocellular tissue

  4. Surgical treatment of complications associated with the Angio-Seal vascular closure device.

    Science.gov (United States)

    Cikirikcioglu, Mustafa; Cherian, Sanjay; Keil, Vera; Manzano, Norman; Gemayel, Gino; Theologou, Thomas; Kalangos, Afksendiyos

    2011-05-01

    Vascular closure devices are used to provide quick hemostasis and early ambulation after percutaneous interventions. The Angio-Seal (AS) vascular closure device forms a mechanical seal by closing the puncture site located between a bioabsorbable anchor within the lumen and a collagen sponge on the adventitia. Although morbidities associated with AS are reportedly infrequent, even the slightest inaccuracy in device implantation may result in displacement of these device components, leading to sudden and severe complications. We report the surgical treatment of complications associated with the use of AS in four patients, including acute limb ischemia, pseudoaneurysm formation, significant hemorrhage, and hypovolemic shock. A common factor in all these cases was that the components of the AS device were displaced from their original site of implantation, stressing the importance of proper device placement. All patients underwent successful surgical vascular repair. Our report highlights the need for exercising extreme care during device implantation, and also the requirement for vigilant inspection for any associated vascular complications commencing immediately after device implantation. It is vital that these device components are actively looked for and removed during surgical exploration so as to prevent future complications. Copyright © 2011. Published by Elsevier Inc.

  5. Vascular remodeling and mineralocorticoids.

    Science.gov (United States)

    Weber, K T; Sun, Y; Campbell, S E; Slight, S H; Ganjam, V K

    1995-01-01

    Circulating mineralocorticoid hormones are so named because of their important homeostatic properties that regulate salt and water balance via their action on epithelial cells. A broader range of functions in nonclassic target cellular sites has been proposed for these steroids and includes their contribution to wound healing following injury. A chronic, inappropriate (relative to intravascular volume and dietary sodium intake) elevation of these circulating hormones evokes a wound healing response in the absence of tissue injury--a wound healing response gone awry. The adverse remodeling of vascularized tissues seen in association with chronic mineralocorticoid excess is the focus of this review.

  6. Implante transapical de valva aórtica: resultados de uma nova prótese brasileira Transapical aortic valve implantation: results of a brazilian prosthesis

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2010-09-01

    procedimento alternativo.OBJECTIVE: The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant. METHODS: After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median Logistic EuroSCORE was 43.7%. Four patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. All patients presented symptoms. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis was implanted through the ventricular apex under ventricular pacing or hemorrhagic shock, after aortic valvoplasty. Echocardiograph and angiograph controls were performed, and the patients were referred to ICU. RESULTS: Implant was feasible in 13 cases. There were no intra-operative deaths. Median peak transvalvular aortic gradient reduced to 25.0 mmHg, and left ventricular function improved in the first seven post-operative days. Paravalvular aortic regurgitation was mild and present in 71%. No definitive pacemaker was needed. There was no peripheral vascular complication. Overall mortality was 42%. CONCLUSION: The transapical implantation of cathetermounted bioprosthesis was a feasible procedure. Long term follow-up is mandatory in order to access efficacy and indications.

  7. Transcatheter aortic valve replacement and vascular complications definitions.

    Science.gov (United States)

    Van Mieghem, Nicolas M; Généreux, Philippe; van der Boon, Robert M A; Kodali, Susheel; Head, Stuart; Williams, Matthew; Daneault, Benoit; Kappetein, Arie-Pieter; de Jaegere, Peter P; Leon, Martin B; Serruys, Patrick W

    2014-03-20

    Transcatheter aortic valve replacement (TAVR) requires large calibre catheters and is therefore associated with increased vascular complications. The aim of this study was to illustrate the impact of the different definitions of major vascular complications on their incidence and to underscore the importance of uniform reporting. We pooled dedicated databases of consecutive patients undergoing TAVR from two tertiary care facilities and looked for the incidence of major vascular complications using various previously reported definitions. The level of agreement (Kappa statistic) between the respective definitions and the Valve Academic Research Consortium (VARC) consensus definition of vascular complications was assessed. A total of 345 consecutive patients underwent transfemoral TAVR and were included in this analysis. A completely percutaneous access and closure technique was applied in 96% of cases. Arterial sheath size ranged between 18 and 24 Fr, the majority being 18 Fr (60%). Procedural success was reached in 94.5%. Depending on the definition used, major vascular complications occurred in 5.2-15.9% of patients. According to the VARC definitions, the rate of major and minor vascular complications was 9.0% and 9.6%, respectively. Major vascular complications according to VARC criteria demonstrated at least a substantial level of agreement with the SOURCE registry (k 0.80), the UK registry (k 0.82) the Italian registry (k 0.72) and "FRANCE" registry (k 0.70) definitions, compared to a moderate level of agreement with the definitions used in the German registry ( 0.47) and the 18 Fr Safety and Efficacy study (k 0.42). Minor complications according to VARC demonstrated a moderate agreement only with vascular complications using the German registry definition (k 0.54). Non-uniformity in how vascular complications are defined precludes any reliable comparison between previously reported TAVR registries. The VARC consensus document offers standardised endpoint

  8. Interventional vascular radiology

    International Nuclear Information System (INIS)

    Yune, H.Y.

    1984-01-01

    The papers published during this past year in the area of interventional vascular radiology presented some useful modifications and further experiences both in the area of thromboembolic therapy and in dilation and thrombolysis, but no new techniques. As an introductory subject, an excellent monograph reviewing the current spectrum of pharmacoangiography was presented in Radiographics. Although the presented material is primarily in diagnostic application of various pharmacologic agents used today to facilitate demonstration of certain diagnostic criteria of various disease processes, both vasodilatory and vasoconstrictive reaction to these agents are widely used in various therapeutic vascular procedures. This monograph should be reviewed by every angiographer whether or not he or she performs interventional procedures, and it would be very convenient to have this table available in the angiography suite. In a related subject, Bookstein and co-workers have written an excellent review concerning pharmacologic manipulations of various blood coagulative parameters during angiography. Understanding the proper method of manipulation of the bloodclotting factors during angiography, and especially during interventional angiography, is extremely important. Particularly, the method of manipulating the coagulation with the use of heparin and protamine and modification of the platelet activity by using aspirin and dipyridamole are succinctly reviewed. The systemic and selective thrombolytic activities of streptokianse are also discussed

  9. Vascular dysfunction in preeclampsia.

    Science.gov (United States)

    Brennan, Lesley J; Morton, Jude S; Davidge, Sandra T

    2014-01-01

    Preeclampsia is a complex disorder which affects an estimated 5% of all pregnancies worldwide. It is diagnosed by hypertension in the presence of proteinuria after the 20th week of pregnancy and is a prominent cause of maternal morbidity and mortality. As delivery is currently the only known treatment, preeclampsia is also a leading cause of preterm delivery. Preeclampsia is associated with maternal vascular dysfunction, leading to serious cardiovascular risk both during and following pregnancy. Endothelial dysfunction, resulting in increased peripheral resistance, is an integral part of the maternal syndrome. While the cause of preeclampsia remains unknown, placental ischemia resulting from aberrant placentation is a fundamental characteristic of the disorder. Poor placentation is believed to stimulate the release of a number of factors including pro- and antiangiogenic factors and inflammatory activators into the maternal systemic circulation. These factors are critical mediators of vascular function and impact the endothelium in distinctive ways, including enhanced endothelial oxidative stress. The mechanisms of action and the consequences on the maternal vasculature will be discussed in this review. © 2013 John Wiley & Sons Ltd.

  10. Preliminary in Vivo Evaluation of a Hybrid Armored Vascular Graft Combining Electrospinning and Additive Manufacturing Techniques

    Directory of Open Access Journals (Sweden)

    Cristiano Spadaccio

    2016-01-01

    Full Text Available In this study, we tested in vivo effectiveness of a previously developed poly-L-lactide/poly-8-caprolactone armored vascular graft releasing heparin. This bioprosthesis was designed in order to overcome the main drawbacks of tissue-engineered vascular grafts, mainly concerning poor mechanical properties, thrombogenicity, and endothelialization. The bioprosthesis was successfully implanted in an aortic vascular reconstruction model in rabbits. All grafts implanted were patent at four weeks postoperatively and have been adequately populated by endogenous cells without signs of thrombosis or structural failure and with no need of antiplatelet therapy. The results of this preliminary study might warrant for further larger controlled in vivo studies to further confirm these findings.

  11. Vascular Remodeling in Experimental Hypertension

    Directory of Open Access Journals (Sweden)

    Norma R. Risler

    2005-01-01

    Full Text Available The basic hemodynamic abnormality in hypertension is an increased peripheral resistance that is due mainly to a decreased vascular lumen derived from structural changes in the small arteries wall, named (as a whole vascular remodeling. The vascular wall is an active, flexible, and integrated organ made up of cellular (endothelial cells, smooth muscle cells, adventitia cells, and fibroblasts and noncellular (extracellular matrix components, which in a dynamic way change shape or number, or reorganize in response to physiological and pathological stimuli, maintaining the integrity of the vessel wall in physiological conditions or participating in the vascular changes in cardiovascular diseases such as hypertension. Research focused on new signaling pathways and molecules that can participate in the mechanisms of vascular remodeling has provided evidence showing that vascular structure is not only affected by blood pressure, but also by mechanisms that are independent of the increased pressure. This review will provide an overview of the evidence, explaining some of the pathophysiologic mechanisms participating in the development of the vascular remodeling, in experimental models of hypertension, with special reference to the findings in spontaneously hypertensive rats as a model of essential hypertension, and in fructose-fed rats as a model of secondary hypertension, in the context of the metabolic syndrome. The understanding of the mechanisms producing the vascular alterations will allow the development of novel pharmacological tools for vascular protection in hypertensive disease.

  12. Vascular pattern formation in plants.

    Science.gov (United States)

    Scarpella, Enrico; Helariutta, Ykä

    2010-01-01

    Reticulate tissue systems exist in most multicellular organisms, and the principles underlying the formation of cellular networks have fascinated philosophers, mathematicians, and biologists for centuries. In particular, the beautiful and varied arrangements of vascular tissues in plants have intrigued mankind since antiquity, yet the organizing signals have remained elusive. Plant vascular tissues form systems of interconnected cell files throughout the plant body. Vascular cells are aligned with one another along continuous lines, and vascular tissues differentiate at reproducible positions within organ environments. However, neither the precise path of vascular differentiation nor the exact geometry of vascular networks is fixed or immutable. Several recent advances converge to reconcile the seemingly conflicting predictability and plasticity of vascular tissue patterns. A control mechanism in which an apical-basal flow of signal establishes a basic coordinate system for body axis formation and vascular strand differentiation, and in which a superimposed level of radial organizing cues elaborates cell patterns, would generate a reproducible tissue configuration in the context of an underlying robust, self-organizing structure, and account for the simultaneous regularity and flexibility of vascular tissue patterns. Copyright 2010 Elsevier Inc. All rights reserved.

  13. The use of tungsten as a chronically implanted material

    Science.gov (United States)

    Shah Idil, A.; Donaldson, N.

    2018-04-01

    This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile strength, and yield point. However, a crucial material criterion for chronically implanted metals is their long-term resistance to corrosion in body fluids, either by inherently noble metallic surfaces, or by protective passivation layers of metal oxide. The latter is often assumed for elemental tungsten, with references to its ‘inertness’ and ‘stability’ common in the literature. This review argues that in the body, metallic tungsten fails this criterion, and will eventually dissolve into the soluble hexavalent form W6+, typically represented by the orthotungstate WO42- (monomeric tungstate) anion. This paper outlines the metal’s unfavourable corrosion thermodynamics in the human physiological environment, the chemical pathways to either metallic or metal oxide dissolution, the rate-limiting steps, and the corrosion-accelerating effects of reactive oxidising species that the immune system produces post-implantation. Multiple examples of implant corrosion have been reported, with failure by dissolution to varying extents up to total loss, with associated emission of tungstate ions and elevated blood serum levels measured. The possible toxicity of these corrosion products has also been explored. As the field of medical implants grows and designers explore novel solutions to medical implant problems, the authors recommend the use of alternative materials.

  14. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  15. Vascular access complications and risk factors in hemodialysis ...

    African Journals Online (AJOL)

    Tarek A. Ghonemy

    2015-08-18

    Aug 18, 2015 ... BMI were significant in patients with central blood infection (p < 0.008, <0.008 and <0.001 ... grafts) for hemodialysis over using the venous catheter as they ... were subjected to the following: thorough full history taking.

  16. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  17. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  18. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  19. Development of the Australasian vascular surgical audit.

    Science.gov (United States)

    Bourke, Bernie M; Beiles, Charles Barry; Thomson, Ian A; Grigg, Michael J; Fitridge, Rob

    2012-01-01

    The purpose of this study was to describe the development of the Australasian Vascular Audit that was created to unify audit activities under the umbrella of the Australian and New Zealand Society for Vascular Surgery as a Web-based application. Constitutional change in late 2008 deemed participation in this audit compulsory for Society members. The Web-based application was developed and tested during 2009. Data for all open vascular surgery and for all endovascular procedures are collected at two points in the admission episode: at the time of operation and at discharge, and entered into the application. Data are analyzed to produce risk-adjusted outcomes. An algorithm has been developed to deal with outliers according to natural justice and to comply with the requirements of regulatory bodies. The Audit is protected by legislated privilege and is officially endorsed and indemnified by the Royal Australasian College of Surgeons. Confidentiality of surgeons and patients alike is ensured by a legally protected coding system and computer encryption system. Validation is by a verification process of 5% of members per year who are randomly selected. The application is completely funded by the Society. Data entry commenced on January 1, 2010. Over 40,000 vascular procedures were entered in the first year. The Audit application allows instantaneous on-line access to individual data and to deidentified group data and specific reports. It also allows real-time instantaneous production of log books for vascular trainees. The Audit has already gained recognition in the Australasian public arena during its first year of operation as an important benchmark of correct professional surgical behavior. Compliance has been extremely high in public hospitals but less so in private hospitals such that only 60% of members received a certificate of complete participation at the end of its first year of operation. An Internet-based compulsory audit of complete surgical practice is

  20. Additive Manufacturing of Vascular Grafts and Vascularized Tissue Constructs.

    Science.gov (United States)

    Elomaa, Laura; Yang, Yunzhi Peter

    2017-10-01

    There is a great need for engineered vascular grafts among patients with cardiovascular diseases who are in need of bypass therapy and lack autologous healthy blood vessels. In addition, because of the severe worldwide shortage of organ donors, there is an increasing need for engineered vascularized tissue constructs as an alternative to organ transplants. Additive manufacturing (AM) offers great advantages and flexibility of fabrication of cell-laden, multimaterial, and anatomically shaped vascular grafts and vascularized tissue constructs. Various inkjet-, extrusion-, and photocrosslinking-based AM techniques have been applied to the fabrication of both self-standing vascular grafts and porous, vascularized tissue constructs. This review discusses the state-of-the-art research on the use of AM for vascular applications and the key criteria for biomaterials in the AM of both acellular and cellular constructs. We envision that new smart printing materials that can adapt to their environment and encourage rapid endothelialization and remodeling will be the key factor in the future for the successful AM of personalized and dynamic vascular tissue applications.

  1. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  2. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  3. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  4. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  5. Rehabilitation of Posterior Maxilla with Zygomatic and Dental Implant after Tumor Resection: A Case Report

    Directory of Open Access Journals (Sweden)

    Faysal Ugurlu

    2013-01-01

    Full Text Available Zygomatic implants have been used for dental rehabilitation in patients with insufficient bone in the posterior upper jaw, due to, for example, tumor resection, trauma, or atrophy. Zygomatic implants are an alternative to complex free or vascularized bone grafting and distraction osteogenesis. A 42-year-old male patient with a severe defect in the right posterior maxilla, starting from the first canine region, which had occurred after tumor resection 3 years earlier, was referred to our department. One zygomatic implant (Brenemark System, Nobel Biocare, Goteborg, Sweden to the zygoma and one dental implant to the canine region were placed. After a 5-month osseointegration period, a fixed denture was fabricated and adapted to the implants. Although the surgical and prosthetic procedures for zygoma implants are not easy, the final outcomes can be successful with appropriate planning.

  6. When routine D-J implantation necessary during PNL?

    Science.gov (United States)

    Bayrak, Omer; Seckiner, Ilker; Erturhan, Sakip M; Bulut, Ersan; Demirbag, Asaf; Erbagci, Asaf

    2015-03-01

    We investigated the characteristics of patients who underwent Double-J catheter (D-J) implantation, the risk factors for prolonged urine leakage (PUL), and prediction of patients who require medical treatment. The data of 535 adult patients who underwent PNL due to kidney stone disease between January 2005 and December 2011 in our clinic were analyzed retrospectively. Patients were divided into 2 groups: Group 1 (n=77) (14.39%) included patients with Double-J catheter due to prolonged (> 24 h) urinary leakage and Group 2 (n=458) (85.61%) patients without urinary leakage. The mean stone burden was 951.94 ± 539.09 mm2 in Group 1, and 676.35 ±296.65 mm2 in Group 2 (p<0.05). DJ catheter was implanted in 11.33% of the patients with stone burden below 1000 mm2 versus in 51.21% of the patients with stone burden above 1000 mm2. In Group 1, the number of patients with two or more accesses performed was 18.18, whereas in Group 2 it was 8.5% (p<0.05). Among all patients, DJ implantation was performed in 13.07% of patients with a single access versus 26.41% of patients with two or more accesses. Also, DJ catheter was implanted in 41.46%of patients with residual stones versus 12.14% of stone-free patients. Three patients with stone burden above 1000 mm2, two or more accesses, and residual stone, all of them required DJ implantation. DJ implantation due to PUL had approximately 5-fold increase stone burden above 1000 mm2, 2-fold increase in patients undergoing two or more access and 3-fold increase in patients with residual stones. Therefore, we think that the D-J implantation is highly advisable in case of a stone load above 1000 mm2, two or more accesses, and in patients with residual stones.

  7. Cardiac and vascular malformations

    International Nuclear Information System (INIS)

    Ley, S.; Ley-Zaporozhan, J.

    2015-01-01

    Malformations of the heart and great vessels show a high degree of variation. There are numerous variants and defects with only few clinical manifestations and are only detected by chance, such as a persistent left superior vena cava or a partial anomalous pulmonary venous connection. Other cardiovascular malformations are manifested directly after birth and need prompt mostly surgical interventions. At this point in time echocardiography is the diagnostic modality of choice for morphological and functional characterization of malformations. Additional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) is only required in a minority of cases. If so, the small anatomical structures, the physiological tachycardia and tachypnea are a challenge for imaging modalities and strategies. This review article presents the most frequent vascular, cardiac and complex cardiovascular malformations independent of the first line diagnostic imaging modality. (orig.) [de

  8. CIRSE Vascular Closure Device Registry

    NARCIS (Netherlands)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. The CIRSE registry of closure devices

  9. Dynamic adaption of vascular morphology

    DEFF Research Database (Denmark)

    Okkels, Fridolin; Jacobsen, Jens Christian Brings

    2012-01-01

    The structure of vascular networks adapts continuously to meet changes in demand of the surrounding tissue. Most of the known vascular adaptation mechanisms are based on local reactions to local stimuli such as pressure and flow, which in turn reflects influence from the surrounding tissue. Here ...

  10. Diagnostic criteria for vascular dementia

    NARCIS (Netherlands)

    Scheltens, P.; Hijdra, A. H.

    1998-01-01

    The term vascular dementia implies the presence of a clinical syndrome (dementia) caused by, or at least assumed to be caused by, a specific disorder (cerebrovascular disease). In this review, the various sets of criteria used to define vascular dementia are outlined. The various sets of criteria

  11. The vascular secret of Klotho

    DEFF Research Database (Denmark)

    Lewin, Ewa; Olgaard, Klaus

    2015-01-01

    Klotho is an evolutionarily highly conserved protein related to longevity. Increasing evidence of a vascular protecting effect of the Klotho protein has emerged and might be important for future treatments of uremic vascular calcification. It is still disputed whether Klotho is locally expressed ...

  12. Open Access

    Science.gov (United States)

    Suber, Peter

    2012-01-01

    The Internet lets us share perfect copies of our work with a worldwide audience at virtually no cost. We take advantage of this revolutionary opportunity when we make our work "open access": digital, online, free of charge, and free of most copyright and licensing restrictions. Open access is made possible by the Internet and copyright-holder…

  13. Open access

    African Journals Online (AJOL)

    Prof. Dennis Ocholla

    The argument that access to information is an instrumental and individual as well as ... and Dean School of Information Studies, University of Wisconsin, Milwaukee, USA. ... to scholarly publications and can be in any digital format, including text, movies and ... language barriers, censorship, lack of access to the Internet and ...

  14. Social media in vascular surgery.

    Science.gov (United States)

    Indes, Jeffrey E; Gates, Lindsay; Mitchell, Erica L; Muhs, Bart E

    2013-04-01

    There has been a tremendous growth in the use of social media to expand the visibility of various specialties in medicine. The purpose of this paper is to describe the latest updates on some current applications of social media in the practice of vascular surgery as well as existing limitations of use. This investigation demonstrates that the use of social networking sites appears to have a positive impact on vascular practice, as is evident through the incorporation of this technology at the Cleveland Clinic and by the Society for Vascular Surgery into their approach to patient care and physician communication. Overall, integration of social networking technology has current and future potential to be used to promote goals, patient awareness, recruitment for clinical trials, and professionalism within the specialty of vascular surgery. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  15. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  16. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  17. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  18. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  19. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  20. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan

    2012-07-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  1. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan; Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  2. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    Science.gov (United States)

    Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O2) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O2-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O2 pressure (pO2) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO2 to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases. PMID:22224628

  3. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  4. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  5. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    Science.gov (United States)

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three

  6. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  7. A Robust Method to Generate Mechanically Anisotropic Vascular Smooth Muscle Cell Sheets for Vascular Tissue Engineering.

    Science.gov (United States)

    Backman, Daniel E; LeSavage, Bauer L; Shah, Shivem B; Wong, Joyce Y

    2017-06-01

    In arterial tissue engineering, mimicking native structure and mechanical properties is essential because compliance mismatch can lead to graft failure and further disease. With bottom-up tissue engineering approaches, designing tissue components with proper microscale mechanical properties is crucial to achieve the necessary macroscale properties in the final implant. This study develops a thermoresponsive cell culture platform for growing aligned vascular smooth muscle cell (VSMC) sheets by photografting N-isopropylacrylamide (NIPAAm) onto micropatterned poly(dimethysiloxane) (PDMS). The grafting process is experimentally and computationally optimized to produce PNIPAAm-PDMS substrates optimal for VSMC attachment. To allow long-term VSMC sheet culture and increase the rate of VSMC sheet formation, PNIPAAm-PDMS surfaces were further modified with 3-aminopropyltriethoxysilane yielding a robust, thermoresponsive cell culture platform for culturing VSMC sheets. VSMC cell sheets cultured on patterned thermoresponsive substrates exhibit cellular and collagen alignment in the direction of the micropattern. Mechanical characterization of patterned, single-layer VSMC sheets reveals increased stiffness in the aligned direction compared to the perpendicular direction whereas nonpatterned cell sheets exhibit no directional dependence. Structural and mechanical anisotropy of aligned, single-layer VSMC sheets makes this platform an attractive microstructural building block for engineering a vascular graft to match the in vivo mechanical properties of native arterial tissue. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. The inflammatory cells in vascular graft anastomosis an electron microscopy study.

    Science.gov (United States)

    Skóra, Jan; Pupka, Artur

    2011-01-01

    In order to determine the processes arising during the healing in vascular grafts the following experiment was desinged in 16 dogs. The animals underwent implantation of unilateral bypass aorto-femoral (straight prosthesis from politetrafluoroethylrne--PTFE). After the 6 months all the animals sacrificed and vascular grafts were dissected and exam in electron microscopy. There were significant differences in the histological findings in structure of neoitima between the proximal and distal anastomoses vascular prostheses. There were evidence of presence of fibroblasts but not macrophages in proximal anastomoses The histological structure of the proximal anastomoses indicates that inflammatory processes was ended during the prosthesis healing. There were presence of macrophages and myofibroblasts, some in the active secretion of collagen in distal anastomoses. Theses images of vascular anastomoses of artery with politerafluoroeth-ylene prosthesis corresponds to the chronic inflammatory reaction in distal anastomoses.

  9. Vascular disease in cocaine addiction.

    Science.gov (United States)

    Bachi, Keren; Mani, Venkatesh; Jeyachandran, Devi; Fayad, Zahi A; Goldstein, Rita Z; Alia-Klein, Nelly

    2017-07-01

    Cocaine, a powerful vasoconstrictor, induces immune responses including cytokine elevations. Chronic cocaine use is associated with functional brain impairments potentially mediated by vascular pathology. Although the Crack-Cocaine epidemic has declined, its vascular consequences are increasingly becoming evident among individuals with cocaine use disorder of that period, now aging. Paradoxically, during the period when prevention efforts could make a difference, this population receives psychosocial treatment at best. We review major postmortem and in vitro studies documenting cocaine-induced vascular toxicity. PubMed and Academic Search Complete were used with relevant terms. Findings consist of the major mechanisms of cocaine-induced vasoconstriction, endothelial dysfunction, and accelerated atherosclerosis, emphasizing acute, chronic, and secondary effects of cocaine. The etiology underlying cocaine's acute and chronic vascular effects is multifactorial, spanning hypertension, impaired homeostasis and platelet function, thrombosis, thromboembolism, and alterations in blood flow. Early detection of vascular disease in cocaine addiction by multimodality imaging is discussed. Treatment may be similar to indications in patients with traditional risk-factors, with few exceptions such as enhanced supportive care and use of benzodiazepines and phentolamine for sedation, and avoiding β-blockers. Given the vascular toxicity cocaine induces, further compounded by smoking and alcohol comorbidity, and interacting with aging of the crack generation, there is a public health imperative to identify pre-symptomatic markers of vascular impairments in cocaine addiction and employ preventive treatment to reduce silent disease progression. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. [The future of vascular medicine].

    Science.gov (United States)

    Kroeger, K; Luther, B

    2014-10-01

    In the future vascular medicine will still have a great impact on health of people. It should be noted that the aging of the population does not lead to a dramatic increase in patient numbers, but will be associated with a changing spectrum of co-morbidities. In addition, vascular medical research has to include the intensive care special features of vascular patients, the involvement of vascular medicine in a holistic concept of fast-track surgery, a geriatric-oriented intensive monitoring and early geriatric rehabilitation. For the future acceptance of vascular medicine as a separate subject area under delimitation of cardiology and radiology is important. On the other hand, the subject is so complex and will become more complex in future specialisations that mixing of surgery and angiology is desirable, with the aim to preserve the vascular surgical knowledge and skills on par with the medical and interventional measures and further develop them. Only large, interdisciplinary guided vascular centres will be able to provide timely diagnosis and therapy, to deal with the growing multi-morbidity of the patient, to perform complex therapies even in an acute emergency and due to sufficient number of cases to present with well-trained and experienced teams. These requirements are mandatory to decrease patients' mortality step by step. Georg Thieme Verlag KG Stuttgart · New York.

  11. Contemporary vascular smartphone medical applications.

    Science.gov (United States)

    Carter, Thomas; O'Neill, Stephen; Johns, Neil; Brady, Richard R W

    2013-08-01

    Use of smartphones and medical mHealth applications (apps) within the clinical environment provides a potential means for delivering elements of vascular care. This article reviews the contemporary availability of apps specifically themed to major vascular diseases and the opportunities and concerns regarding their integration into practice. Smartphone apps relating to major vascular diseases were identified from the app stores for the 6 most popular smartphone platforms, including iPhone, Android, Blackberry, Nokia, Windows, and Samsung. Search terms included peripheral artery (arterial) disease, varicose veins, aortic aneurysm, carotid artery disease, amputation, ulcers, hyperhydrosis, thoracic outlet syndrome, vascular malformation, and lymphatic disorders. Forty-nine vascular-themed apps were identified. Sixteen (33%) were free of charge. Fifteen apps (31%) had customer satisfaction ratings, but only 3 (6%) had greater than 100. Only 13 apps (27%) had documented medical professional involvement in their design or content. The integration of apps into the delivery of care has the potential to benefit vascular health care workers and patients. However, high-quality apps designed by clinicians with vascular expertise are currently lacking and represent an area of concern in the mHealth market. Improvement in the quality and reliability of these apps will require the development of robust regulation. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Access Contested

    International Development Research Centre (IDRC) Digital Library (Canada)

    Transforming Global Information and Communication Markets: The Political Economy of ... 8 Control and Resistance: Attacks on Burmese Opposition Media 153 ...... “Reluctant Gatekeepers: Corporate Ethics on a Filtered Internet,” in Access ...

  13. Accessing memory

    Science.gov (United States)

    Yoon, Doe Hyun; Muralimanohar, Naveen; Chang, Jichuan; Ranganthan, Parthasarathy

    2017-09-26

    A disclosed example method involves performing simultaneous data accesses on at least first and second independently selectable logical sub-ranks to access first data via a wide internal data bus in a memory device. The memory device includes a translation buffer chip, memory chips in independently selectable logical sub-ranks, a narrow external data bus to connect the translation buffer chip to a memory controller, and the wide internal data bus between the translation buffer chip and the memory chips. A data access is performed on only the first independently selectable logical sub-rank to access second data via the wide internal data bus. The example method also involves locating a first portion of the first data, a second portion of the first data, and the second data on the narrow external data bus during separate data transfers.

  14. Constructal vascularized structures

    Science.gov (United States)

    Cetkin, Erdal

    2015-06-01

    Smart features such as self-healing and selfcooling require bathing the entire volume with a coolant or/and healing agent. Bathing the entire volume is an example of point to area (or volume) flows. Point to area flows cover all the distributing and collecting kinds of flows, i.e. inhaling and exhaling, mining, river deltas, energy distribution, distribution of products on the landscape and so on. The flow resistances of a point to area flow can be decreased by changing the design with the guidance of the constructal law, which is the law of the design evolution in time. In this paper, how the flow resistances (heat, fluid and stress) can be decreased by using the constructal law is shown with examples. First, the validity of two assumptions is surveyed: using temperature independent Hess-Murray rule and using constant diameter ducts where the duct discharges fluid along its edge. Then, point to area types of flows are explained by illustrating the results of two examples: fluid networks and heating an area. Last, how the structures should be vascularized for cooling and mechanical strength is documented. This paper shows that flow resistances can be decreased by morphing the shape freely without any restrictions or generic algorithms.

  15. Forbidden Access

    CERN Multimedia

    C. Colloca TS/FM

    2004-01-01

    TS/FM group informs you that, for the replacement of the door of the main entrance at bldg. 500, the access will be closed to the public between 19 and 30 July 2004. Access to the Main Building complex will be assured at any time through both of the side doors and from bldg. 64. For more information, please contact 73273. C. Colloca TS/FM

  16. In vitro model of vascularized bone: synergizing vascular development and osteogenesis.

    Directory of Open Access Journals (Sweden)

    Cristina Correia

    Full Text Available Tissue engineering provides unique opportunities for regenerating diseased or damaged tissues using cells obtained from tissue biopsies. Tissue engineered grafts can also be used as high fidelity models to probe cellular and molecular interactions underlying developmental processes. In this study, we co-cultured human umbilical vein endothelial cells (HUVECs and human mesenchymal stem cells (MSCs under various environmental conditions to elicit synergistic interactions leading to the colocalized development of capillary-like and bone-like tissues. Cells were encapsulated at the 1:1 ratio in fibrin gel to screen compositions of endothelial growth medium (EGM and osteogenic medium (OM. It was determined that, to form both tissues, co-cultures should first be supplied with EGM followed by a 1:1 cocktail of the two media types containing bone morphogenetic protein-2. Subsequent studies of HUVECs and MSCs cultured in decellularized, trabecular bone scaffolds for 6 weeks assessed the effects on tissue construct of both temporal variations in growth-factor availability and addition of fresh cells. The resulting grafts were implanted subcutaneously into nude mice to determine the phenotype stability and functionality of engineered vessels. Two important findings resulted from these studies: (i vascular development needs to be induced prior to osteogenesis, and (ii the addition of additional hMSCs at the osteogenic induction stage improves both tissue outcomes, as shown by increased bone volume fraction, osteoid deposition, close proximity of bone proteins to vascular networks, and anastomosis of vascular networks with the host vasculature. Interestingly, these observations compare well with what has been described for native development. We propose that our cultivation system can mimic various aspects of endothelial cell-osteogenic precursor interactions in vivo, and could find utility as a model for studies of heterotypic cellular interactions that

  17. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  18. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  19. Pattern of Bone Generation after Irradiation in Vascularized Tissue Engineered Constructs.

    Science.gov (United States)

    Eweida, Ahmad; Fathi, Ibrahim; Eltawila, Ahmed M; Elsherif, Ahmad M; Elkerm, Yasser; Harhaus, Leila; Kneser, Ulrich; Sakr, Mahmoud F

    2018-02-01

     Regenerative medicine modalities provide promising alternatives to conventional reconstruction techniques but are still deficient after malignant tumor excision or irradiation due to defective vascularization.  We investigated the pattern of bone formation in axially vascularized tissue engineering constructs (AVTECs) after irradiation in a study that mimics the clinical scenario after head and neck cancer. Heterotopic bone generation was induced in a subcutaneously implanted AVTEC in the thigh of six male New Zealand rabbits. The tissue construct was made up of Nanobone (Artoss GmbH; Rostock, Germany) granules mixed with autogenous bone marrow and 80 μL of bone morphogenic protein-2 at a concentration of 1.5 μg/μL. An arteriovenous loop was created microsurgically between the saphenous vessels and implanted in the core of the construct to induce axial vascularization. The constructs were subjected to external beam irradiation on postoperative day 20 with a single dose of 15 Gy. The constructs were removed 20 days after irradiation and subjected to histological and immunohistochemical analysis for vascularization, bone formation, apoptosis, and cellular proliferation.  The vascularized constructs showed homogenous vascularization and bone formation both in their central and peripheral regions. Although vascularity, proliferation, and apoptosis were similar between central and peripheral regions of the constructs, significantly more bone was formed in the central regions of the constructs.  The study shows for the first time the pattern of bone formation in AVTECs after irradiation using doses comparable to those applied after head and neck cancer. Axial vascularization probably enhances the osteoinductive properties in the central regions of AVTECs after irradiation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  1. Immediate outcomes of eptifibatide therapy during intracoronary stent implantation.

    Science.gov (United States)

    Shariati, Hooman; Sanei, Hamid; Pourmoghadas, Ali; Salehizadeh, Leila; Amirpour, Afshin

    2016-01-01

    The objective of the present study was to assess the major immediate outcomes of eptifibatide therapy during intracoronary stent implantation. In an interventional study, patients undergoing percutaneous coronary intervention (PCI) were randomized into either the eptifibatide ( n = 100) or the control ( n = 107) group. In each group, demographic and clinical characteristics such as cardiac death, stent thrombosis (ST), myocardial infarction (MI), rates of target lesion and vessel revascularization, cerebral vascular accident (CVA), and emergency coronary artery bypass grafting (CABG) were recorded. The overall rates of major adverse events such as mortality, Stent thrombosis (ST), Myocardial Infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), CVA, and emergency CABG within 24 h after stent implantation were low and comparable between the two groups; P > 0.05 considered significant for all comparisons. There were no statistical differences between the clinical outcomes of groups administered with single-dose intracoronary eptifibatide and control groups among patients undergoing PCI during stent implantation.

  2. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  3. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  4. Arterial grafts exhibiting unprecedented cellular infiltration and remodeling in vivo: the role of cells in the vascular wall.

    Science.gov (United States)

    Row, Sindhu; Peng, Haofan; Schlaich, Evan M; Koenigsknecht, Carmon; Andreadis, Stelios T; Swartz, Daniel D

    2015-05-01

    To engineer and implant vascular grafts in the arterial circulation of a pre-clinical animal model and assess the role of donor medial cells in graft remodeling and function. Vascular grafts were engineered using Small Intestinal Submucosa (SIS)-fibrin hybrid scaffold and implanted interpositionally into the arterial circulation of an ovine model. We sought to demonstrate implantability of SIS-Fibrin based grafts; examine the remodeling; and determine whether the presence of vascular cells in the medial wall was necessary for cellular infiltration from the host and successful remodeling of the implants. We observed no occlusions or anastomotic complications in 18 animals that received these grafts. Notably, the grafts exhibited unprecedented levels of host cell infiltration that was not limited to the anastomotic sites but occurred through the lumen as well as the extramural side, leading to uniform cell distribution. Incoming cells remodeled the extracellular matrix and matured into functional smooth muscle cells as evidenced by expression of myogenic markers and development of vascular reactivity. Interestingly, tracking the donor cells revealed that their presence was beneficial but not necessary for successful grafting. Indeed, the proliferation rate and number of donor cells decreased over time as the vascular wall was dominated by host cells leading to significant remodeling and development of contractile function. These results demonstrate that SIS-Fibrin grafts can be successfully implanted into the arterial circulation of a clinically relevant animal model, improve our understanding of vascular graft remodeling and raise the possibility of engineering mural cell-free arterial grafts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Vascular injury is associated with increased mortality in winter sports trauma.

    Science.gov (United States)

    Eun, John C; Bronsert, Michael; Hansen, Kristine; Moulton, Steven L; Jazaeri, Omid; Nehler, Mark; Greenberg, Joshua I

    2015-01-01

    Trauma is the leading cause of injury and death for individuals aged 1-44 years. Up to 8% of the US population participates in winter sports, and although vascular injuries are uncommon in these activities, little is published in this area. We sought to identify the incidence, injury patterns, and outcomes of vascular injuries resulting from winter sports trauma. Patients with winter sports trauma and the subset with vascular injuries were identified by accessing the National Trauma Data Bank querying years 2007-2010. Patients with and without vascular injuries were then compared. Admission variables included transport time, emergency department hypotension (systolic blood pressure Injury Severity Score ≥ 25, fractures, solid organ injury, and vascular injury. Outcomes were analyzed and associations with vascular injuries were determined. A total of 2,298 patients were identified with winter sports-related trauma and 28 (1.2%) had associated vascular injuries. Overall, the top 3 injuries were head trauma (16.7%), thoracic vertebral fractures (5.5%), and lumbar vertebral fractures (5.1%). The most common associated vascular injures were to the popliteal artery (17.7%), splenic artery (14.7%), and brachial blood vessels (14.7%). In the entire cohort, 1 patient (0.04%) suffered an amputation and 15 patients (0.7%) died. There were no amputations in the vascular injury group. Mortality was 0.6% in patients without a vascular injury compared with 7.1% of those with a vascular injury (P = 0.01). Although vascular injury is an uncommon associated finding in winter sports trauma, it is associated with a significant increase in mortality. These findings highlight the need for rapid identification of traumatic vascular injuries, which predicts worse overall outcomes in this patient population. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Diabetes and Retinal Vascular Dysfunction

    Directory of Open Access Journals (Sweden)

    Eui Seok Shin

    2014-01-01

    Full Text Available Diabetes predominantly affects the microvascular circulation of the retina resulting in a range of structural changes unique to this tissue. These changes ultimately lead to altered permeability, hyperproliferation of endothelial cells and edema, and abnormal vascularization of the retina with resulting loss of vision. Enhanced production of inflammatory mediators and oxidative stress are primary insults with significant contribution to the pathogenesis of diabetic retinopathy (DR. We have determined the identity of the retinal vascular cells affected by hyperglycemia, and have delineated the cell autonomous impact of high glucose on function of these cells. We discuss some of the high glucose specific changes in retinal vascular cells and their contribution to retinal vascular dysfunction. This knowledge provides novel insight into the molecular and cellular defects contributing to the development and progression of diabetic retinopathy, and will aid in the development of innovative, as well as target specific therapeutic approaches for prevention and treatment of DR.

  7. Accessible Knowledge - Knowledge on Accessibility

    DEFF Research Database (Denmark)

    Kirkeby, Inge Mette

    2015-01-01

    Although serious efforts are made internationally and nationally, it is a slow process to make our physical environment accessible. In the actual design process, architects play a major role. But what kinds of knowledge, including research-based knowledge, do practicing architects make use of when...... designing accessible environments? The answer to the question is crucially important since it affects how knowledge is distributed and how accessibility can be ensured. In order to get first-hand knowledge about the design process and the sources from which they gain knowledge, 11 qualitative interviews...... were conducted with architects with experience of designing for accessibility. The analysis draws on two theoretical distinctions. The first is research-based knowledge versus knowledge used by architects. The second is context-independent knowledge versus context-dependent knowledge. The practitioners...

  8. Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.

    Science.gov (United States)

    Doyle, Brendan J; Godfrey, Michael J; Lennon, Ryan J; Ryan, James L; Bresnahan, John F; Rihal, Charanjit S; Ting, Henry H

    2007-02-01

    The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications. (c) 2006 Wiley-Liss, Inc.

  9. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  10. Limb vascular function in women

    DEFF Research Database (Denmark)

    Hellsten, Ylva; Gliemann, Lasse

    2018-01-01

    Throughout life, women are subjected to both acute fluctuations in sex hormones, associated with the menstrual cycle, and chronic changes following the onset of menopause. Female sex hormones, and in particular estrogen, strongly influence cardiovascular function such as the regulation of vascular...... studies. Physical activity should be recommended for women of all ages, but the most essential timing for maintenance of vascular health may be from menopause and onwards....

  11. Facial vascular malformations in children

    International Nuclear Information System (INIS)

    Brunelle, F.O.; Lallemand, D.; Chaumont, P.; Teillac, D.; Manach, Y.

    1988-01-01

    The authors present their experience with conventional and digital angiography of vascular malformations of the head and neck in children. 22 hemangioendotheliomas, 8 venous angiomas, and 3 arteriovenous fistula were studied. 22 patients were embolised. DSA offers many advantages during the diagnostic as well as during the therapeutic phase of angiography. Embolization appears to have a major role in treatment of such vascular malformations. (orig.)

  12. Open access

    CERN Document Server

    Suber, Peter

    2012-01-01

    The Internet lets us share perfect copies of our work with a worldwide audience at virtually no cost. We take advantage of this revolutionary opportunity when we make our work "open access": digital, online, free of charge, and free of most copyright and licensing restrictions. Open access is made possible by the Internet and copyright-holder consent, and many authors, musicians, filmmakers, and other creators who depend on royalties are understandably unwilling to give their consent. But for 350 years, scholars have written peer-reviewed journal articles for impact, not for money, and are free to consent to open access without losing revenue. In this concise introduction, Peter Suber tells us what open access is and isn't, how it benefits authors and readers of research, how we pay for it, how it avoids copyright problems, how it has moved from the periphery to the mainstream, and what its future may hold. Distilling a decade of Suber's influential writing and thinking about open access, this is the indispe...

  13. Patient-specific cardiovascular progenitor cells derived from integration-free induced pluripotent stem cells for vascular tissue regeneration.

    Science.gov (United States)

    Hu, Jiang; Wang, Yongyu; Jiao, Jiao; Liu, Zhongning; Zhao, Chao; Zhou, Zhou; Zhang, Zhanpeng; Forde, Kaitlynn; Wang, Lunchang; Wang, Jiangang; Baylink, David J; Zhang, Xiao-Bing; Gao, Shaorong; Yang, Bo; Chen, Y Eugene; Ma, Peter X

    2015-12-01

    Tissue-engineered blood vessels (TEBVs) are promising in regenerating a live vascular replacement. However, the vascular cell source is limited, and it is crucial to develop a scaffold that accommodates new type of vascular progenitor cells and facilitates in vivo lineage specification of the cells into functional vascular smooth muscle cells (VSMCs) to regenerate vascular tissue. In the present study, integration-free human induced pluripotent stem cells (hiPSCs) were established from patient peripheral blood mononuclear cells through episomal vector nucleofection of reprogramming factors. The established hiPSCs were then induced into mesoderm-originated cardiovascular progenitor cells (CVPCs) with a highly efficient directed lineage specification method. The derived CVPCs were demonstrated to be able to differentiate into functional VSMCs. Subcutaneous implantation of CVPCs seeded on macroporous nanofibrous poly(l-lactide) scaffolds led to in vivo VSMC lineage specification and matrix deposition inside the scaffolds. In summary, we established integration-free patient-specific hiPSCs from peripheral blood mononuclear cells, derived CVPCs through directed lineage specification, and developed an advanced scaffold for these progenitor cells to further differentiate in vivo into VSMCs and regenerate vascular tissue in a subcutaneous implantation model. This study has established an efficient patient-specific approach towards in vivo regeneration of vascular tissue. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Angiogenesis, Cancer, and Vascular Aging

    Directory of Open Access Journals (Sweden)

    Junji Moriya

    2017-10-01

    Full Text Available Several lines of evidence have revealed that the angiogenic response to ischemic injury declines with age, which might account for the increased morbidity and mortality of cardiovascular disease (CVD among the elderly. While impairment of angiogenesis with aging leads to delayed wound healing or exacerbation of atherosclerotic ischemic diseases, it also inhibits the progression of cancer. Age-related changes of angiogenesis have been considered to at least partly result from vascular aging or endothelial cell senescence. There is considerable evidence supporting the hypothesis that vascular cell senescence contributes to the pathogenesis of age-related CVD, suggesting that vascular aging could be an important therapeutic target. Since therapeutic angiogenesis is now regarded as a promising concept for patients with ischemic CVD, it has become even more important to understand the detailed molecular mechanisms underlying impairment of angiogenesis in older patients. To improve the usefulness of therapeutic angiogenesis, approaches are needed that can compensate for impaired angiogenic capacity in the elderly while not promoting the development or progression of malignancy. In this review, we briefly outline the mechanisms of angiogenesis and vascular aging, followed by a description of how vascular aging leads to impairment of angiogenesis. We also examine potential therapeutic approaches that could enhance angiogenesis and/or vascular function in the elderly, as well as discussing the possibility of anti-senescence therapy or reversal of endothelial cell senescence.

  15. Incorporation of a prolyl hydroxylase inhibitor into scaffolds: a strategy for stimulating vascularization.

    Science.gov (United States)

    Sham, Adeline; Martinez, Eliana C; Beyer, Sebastian; Trau, Dieter W; Raghunath, Michael

    2015-03-01

    Clinical applications of tissue engineering are constrained by the ability of the implanted construct to invoke vascularization in adequate extent and velocity. To overcome the current limitations presented by local delivery of single angiogenic factors, we explored the incorporation of prolyl hydroxylase inhibitors (PHIs) into scaffolds as an alternative vascularization strategy. PHIs are small molecule drugs that can stabilize the alpha subunit of hypoxia-inducible factor-1 (HIF-1), a key transcription factor that regulates a variety of angiogenic mechanisms. In this study, we conjugated the PHI pyridine-2,4-dicarboxylic acid (PDCA) through amide bonds to a gelatin sponge (Gelfoam(®)). Fibroblasts cultured on PDCA-Gelfoam were able to infiltrate and proliferate in these scaffolds while secreting significantly more vascular endothelial growth factor than cells grown on Gelfoam without PDCA. Reporter cells expressing green fluorescent protein-tagged HIF-1α exhibited dose-dependent stabilization of this angiogenic transcription factor when growing within PDCA-Gelfoam constructs. Subsequently, we implanted PDCA-Gelfoam scaffolds into the perirenal fat tissue of Sprague Dawley rats for 8 days. Immunostaining of explants revealed that the PDCA-Gelfoam scaffolds were amply infiltrated by cells and promoted vascular ingrowth in a dose-dependent manner. Thus, the incorporation of PHIs into scaffolds appears to be a feasible strategy for improving vascularization in regenerative medicine applications.

  16. Triple-Layer Vascular Grafts Fabricated by Combined E-Jet 3D Printing and Electrospinning.

    Science.gov (United States)

    Huang, Ruiying; Gao, Xiangkai; Wang, Jian; Chen, Haoxiang; Tong, Chunyi; Tan, Yongjun; Tan, Zhikai

    2018-05-29

    Small-diameter tissue-engineered vascular grafts are urgently needed for clinic arterial substitute. To simulate the structures and functions of natural blood vessels, we designed a novel triple-layer poly(ε-caprolactone) (PCL) fibrous vascular graft by combining E-jet 3D printing and electrospinning techniques. The resultant vascular graft consisted of an interior layer comprising 3D-printed highly aligned strong fibers, a middle layer made by electrospun densely fibers, and an exterior structure composed of mixed fibers fabricated by co-electrospraying. The biocompatible triple-layer graft was used for in vivo implantation, and results demonstrated that the longitudinally-aligned fibers within the lumen of the graft could enhance the proliferation and migration of endothelial cells, while maintained good mechanical properties. The exterior layer provided a pathway that encouraged cells to migrate into the scaffold after implantation. This experimental graft overcame the limitations of conventionally electrospun vascular grafts of inadequate porosity and lowly cell penetration. The unique structure of the triple-layer vascular graft promoted cell growth and infiltration in vivo, thus provided an encouraging substitute for in situ tissue engineering.

  17. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  18. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  19. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  20. Prefabrication of axial vascularized tissue engineering coral bone by an arteriovenous loop: a better model.

    Science.gov (United States)

    Dong, Qing-shan; Shang, Hong-tao; Wu, Wei; Chen, Fu-lin; Zhang, Jun-rui; Guo, Jia-ping; Mao, Tian-qiu

    2012-08-01

    The most important problem for the survival of thick 3-dimensional tissues is the lack of vascularization in the context of bone tissue engineering. In this study, a modified arteriovenous loop (AVL) was developed to prefabricate an axial vascularized tissue engineering coral bone in rabbit, with comparison of the arteriovenous bundle (AVB) model. An arteriovenous fistula between rabbit femoral artery and vein was anastomosed to form an AVL. It was placed in a circular side groove of the coral block. The complex was wrapped with an expanded-polytetrafluoroethylene membrane and implanted beneath inguinal skin. After 2, 4, 6 and 8 weeks, the degree of vascularization was evaluated by India ink perfusion, histological examination, vascular casts, and scanning electron microscopy images of vascular endangium. Newly formed fibrous tissues and vasculature extended over the surfaces and invaded the interspaces of entire coral block. The new blood vessels robustly sprouted from the AVL. Those invaginated cavities in the vascular endangium from scanning electron microscopy indicated vessel's sprouted pores. Above indexes in AVL model are all superior to that in AVB model, indicating that the modified AVL model could more effectively develop vascularization in larger tissue engineering bone. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Nano- and microstructured materials for in vitro studies of the physiology of vascular cells

    Directory of Open Access Journals (Sweden)

    Alexandra M. Greiner

    2016-11-01

    Full Text Available The extracellular environment of vascular cells in vivo is complex in its chemical composition, physical properties, and architecture. Consequently, it has been a great challenge to study vascular cell responses in vitro, either to understand their interaction with their native environment or to investigate their interaction with artificial structures such as implant surfaces. New procedures and techniques from materials science to fabricate bio-scaffolds and surfaces have enabled novel studies of vascular cell responses under well-defined, controllable culture conditions. These advancements are paving the way for a deeper understanding of vascular cell biology and materials–cell interaction. Here, we review previous work focusing on the interaction of vascular smooth muscle cells (SMCs and endothelial cells (ECs with materials having micro- and nanostructured surfaces. We summarize fabrication techniques for surface topographies, materials, geometries, biochemical functionalization, and mechanical properties of such materials. Furthermore, various studies on vascular cell behavior and their biological responses to micro- and nanostructured surfaces are reviewed. Emphasis is given to studies of cell morphology and motility, cell proliferation, the cytoskeleton and cell-matrix adhesions, and signal transduction pathways of vascular cells. We finalize with a short outlook on potential interesting future studies.

  2. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  3. Dynamic, nondestructive imaging of a bioengineered vascular graft endothelium.

    Directory of Open Access Journals (Sweden)

    Bryce M Whited

    Full Text Available Bioengineering of vascular grafts holds great potential to address the shortcomings associated with autologous and conventional synthetic vascular grafts used for small diameter grafting procedures. Lumen endothelialization of bioengineered vascular grafts is essential to provide an antithrombogenic graft surface to ensure long-term patency after implantation. Conventional methods used to assess endothelialization in vitro typically involve periodic harvesting of the graft for histological sectioning and staining of the lumen. Endpoint testing methods such as these are effective but do not provide real-time information of endothelial cells in their intact microenvironment, rather only a single time point measurement of endothelium development. Therefore, nondestructive methods are needed to provide dynamic information of graft endothelialization and endothelium maturation in vitro. To address this need, we have developed a nondestructive fiber optic based (FOB imaging method that is capable of dynamic assessment of graft endothelialization without disturbing the graft housed in a bioreactor. In this study we demonstrate the capability of the FOB imaging method to quantify electrospun vascular graft endothelialization, EC detachment, and apoptosis in a nondestructive manner. The electrospun scaffold fiber diameter of the graft lumen was systematically varied and the FOB imaging system was used to noninvasively quantify the affect of topography on graft endothelialization over a 7-day period. Additionally, results demonstrated that the FOB imaging method had a greater imaging penetration depth than that of two-photon microscopy. This imaging method is a powerful tool to optimize vascular grafts and bioreactor conditions in vitro, and can be further adapted to monitor endothelium maturation and response to fluid flow bioreactor preconditioning.

  4. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  5. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  6. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  7. Access French

    CERN Document Server

    Grosz, Bernard

    2014-01-01

    Access is the major new language series designed with the needs of today's generation of students firmly in mind. Whether learning for leisure or business purposes or working towards a curriculum qualification, Access French is specially designed for adults of all ages and gives students a thorough grounding in all the skills required to understand, speak, read and write contemporary French from scratch. The coursebook consists of 10 units covering different topic areas, each of which includes Language Focus panels explaining the structures covered and a comprehensive glossary. Learning tips

  8. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  9. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  10. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  11. Calcium dynamics in vascular smooth muscle

    OpenAIRE

    Amberg, Gregory C.; Navedo, Manuel F.

    2013-01-01

    Smooth muscle cells are ultimately responsible for determining vascular luminal diameter and blood flow. Dynamic changes in intracellular calcium are a critical mechanism regulating vascular smooth muscle contractility. Processes influencing intracellular calcium are therefore important regulators of vascular function with physiological and pathophysiological consequences. In this review we discuss the major dynamic calcium signals identified and characterized in vascular smooth muscle cells....

  12. Optimization of a therapeutic electromagnetic field (EMF) to retard breast cancer tumor growth and vascularity

    OpenAIRE

    Cameron, Ivan L; Markov, Marko S; Hardman, W Elaine

    2014-01-01

    Background This study provided additional data on the effects of a therapeutic electromagnetic field (EMF) device on growth and vascularization of murine 16/C mammary adenocarcinoma cells implanted in C3H/HeJ mice. Methods The therapeutic EMF device generated a defined 120 Hz semi sine wave pulse signal of variable intensity. Murine 16/C mammary adenocarcinoma tumor fragments were implanted subcutaneously between the scapulae of syngeneic C3H mice. Once the tumor grew to 100 mm3, daily EMF tr...

  13. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  14. Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

    Science.gov (United States)

    Elmengaard, Brian; Baas, Joergen; Jakobsen, Thomas; Kold, Soren; Jensen, Thomas B; Bechtold, Joan E; Soballe, Kjeld

    2017-02-01

    We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 μm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. The grafted crack revision improved

  15. Injuries to the vascular endothelium: vascular wall and endothelial dysfunction.

    Science.gov (United States)

    Fisher, Mark

    2008-01-01

    Vascular endothelial injury has multiple elements, and this article focuses on ischemia-related processes that have particular relevance to ischemic stroke. Distinctions between necrotic and apoptotic cell death provide a basic science context in which to better understand the significance of classical core and penumbra concepts of acute stroke, with apoptotic processes particularly prominent in the penumbra. The mitochondria are understood to serve as a reservoir of proteins that mediate apoptosis. Oxidative stress pathways generating reactive oxygen species (ROS) are prominent in endothelial injury, both ischemic and nonischemic, with prominent roles of enzyme- and nonenzymemediated pathways; mitochondria once again have a critical role, particularly in the nonenzymatic pathways generating ROS. Inflammation also contributes to vascular endothelial injury, and endothelial cells have the capacity to rapidly increase expression of inflammatory mediators following ischemic challenge; this leads to enhanced leukocyte-endothelial interactions mediated by selectins and adhesion molecules. Preconditioning consists of a minor version of an injurious event, which in turn may protect vascular endothelium from injury following a more substantial event. Presence of the blood-brain barrier creates unique responses to endothelial injury, with permeability changes due to impairment of endothelial-matrix interactions compounding altered vasomotor tone and tissue perfusion mediated by nitric oxide. Pharmacological protection against vascular endothelial injury can be provided by several of the phosphodiesterases (cilostazol and dipyridamole), along with statins. Optimal clinical responses for protection of brain vascular endothelium may use preconditioning as a model, and will likely require combined protection against apoptosis, ROS, and inflammation.

  16. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  17. Estudio in vitro de permeabilidad, porosidad y crecimiento celular en membranas electrohiladas para prótesis vasculares

    Directory of Open Access Journals (Sweden)

    Raúl A. Valencia

    2017-03-01

    Conclusiones: La variación de estructuras microporosas de gran área superficial para obtener implantes con la técnica de electrospinning, incide en el crecimiento celular y subsecuentemente en la permeabilidad y la porosidad, hecho que abre una gran oportunidad para su uso potencial en aplicaciones vasculares de diámetros pequeños.

  18. Meniscal repair by fibrocartilage in the dog : Characterization of the repair tissue and the role of vascularity

    NARCIS (Netherlands)

    Veth, RPH; Jansen, HWB; Nielsen, HKL; deGroot, JH; Pennings, AJ; Kuijer, R

    Lesions in the avascular part of 20 canine menisci were repaired by implantation of a porous polyurethane. Seven menisci were not repaired and served as controls. The repair tissue was characterized by biochemical and immunological analysis. The role of vascularity in healing was studied by

  19. Gaining Access.

    Science.gov (United States)

    Wand, Sean; Thermos, Adam C.

    1998-01-01

    Explains the issues to consider before a college decides to purchase a card-access system. The benefits of automation, questions involving implementation, the criteria for technology selection, what typical card technology involves, privacy concerns, and the placement of card readers are discussed. (GR)

  20. Increase in Vascular Injury of Sodium Overloaded Mice May be Related to Vascular Angiotensin Modulation.

    Directory of Open Access Journals (Sweden)

    Cintia Taniguti Lima

    Full Text Available This study aimed to analyzing the effect of chronic sodium overload upon carotid and femoral injury, and its relation to vascular angiotensin modulation. Male C57Bl6 mice were divided in: control (cont, receiving 1% NaCl solution for 2 weeks (salt-2 or 12 weeks (salt-12. Two-weeks before the end of the study, a 2mm catheter was implanted around the left femoral and carotid arteries to induce injury. Blood pressure (BP and heart rate (HR were measured at the end of the study by tail plethysmography. Arteries were collected and prepared for histological analysis to determine arterial thickening and perivascular collagen deposition. Angiotensin II and Ang(1-7 were quantified in fresh arteries using the HPLC method. There were no differences in body weight, BP and HR. Intima/media ratio had a similar increase in both injured arteries of cont and salt-2 mice, but a more pronounced increase was observed in salt-12 mice (31.1±6%. On the other hand, sodium overload modified perivascular collagen deposition, increasing thick fibers (cont: 0.5%; salt-2: 3.4%; salt-12: 0.6% and decreasing thin fibers (cont: 7.4%; salt-2: 0.5%; salt-12: 6.8% in non-injured arteries. Injured arteries presented similar collagen fiber distribution. Angiotensin quantification showed increased Ang(1-7 in salt treated mice (salt-2: +72%; salt-12: +45% with a concomitant decrease in Ang II (salt-2: -54%; salt-12: -60%. Vascular injury increased significantly Ang(1-7 in salt-12 mice (+80%, maintaining Ang II reduction similar to that of a non-injured artery. The lack of changes in BP and HR suggests that the structural changes observed may be due to non-hemodynamic mechanisms such as local renin-angiotensin system. Collagen evaluation suggests that sodium overload induces time-related changes in vascular remodeling. The increase of artery injury with concomitant increase in Ang(1-7 in 12-week treated mice shows a direct association between the duration of salt treatment and the

  1. Implantable Body Sensor Network MAC Protocols Using Wake-up Radio – Evaluation in Animal Tissue

    NARCIS (Netherlands)

    Karuppiah Ramachandran, Vignesh Raja; van der Zwaag, B.J.; Meratnia, Nirvana; Havinga, Paul J.M.

    Applications of implantable sensor networks in the health-care industry have increased tremendously over the last decade. There are different types of medium access control (MAC) protocols that are designed for implantable body sensor networks, using different physical layer technologies such as

  2. International survey of cochlear implant candidacy.

    Science.gov (United States)

    Vickers, D; De Raeve, L; Graham, J

    2016-04-01

    The goal of this work was to determine international differences in candidacy based on audiometric and speech perception measures, and to evaluate the information in light of the funding structure and access to implants within different countries. An online questionnaire was circulated to professionals in 25 countries. There were 28 respondents, representing the candidacy practice in 17 countries. Results showed differences in the funding model between countries. Unilateral implants for both adults and children and bilateral implants for children were covered by national funding in approximately 60% of countries (30% used medical insurance, and 10% self-funding). Fewer countries provided bilateral implants routinely for adults: national funding was available in only 22% (37% used medical insurance and 41% self-funding). Main evolving candidacy areas are asymmetric losses, auditory neuropathy spectrum disorders and electro-acoustic stimulation. For countries using speech-based adult candidacy assessments, the majority (40%) used word tests, 24% used sentence tests, and 36% used a mixture of both. For countries using audiometry for candidacy (70-80% of countries), the majority used levels of 75-85 dB HL at frequencies above 1 kHz. The United Kingdom and Belgium had the most conservative audiometric criteria, and countries such as Australia, Germany, and Italy were the most lenient. Countries with a purely self-funding model had greater flexibility in candidacy requirements.

  3. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy.

    Science.gov (United States)

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B; Schmidlin, Patrick R; Attin, Thomas; Sahrmann, Philipp

    2017-11-28

    An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two blinded examiners evaluated standardized photographs of 360 initially ink-stained dental implants, which were cleaned at variable defect angulations (30, 60, or 90°), using different instrument types (Gracey curette, ultrasonic scaler or air powder abrasive device) and treatment approaches (SA or NSA). Predefined implant surface areas were graded for residual stain using scores ranging from one (stain-covered) to six (clean). Score differences between respective implant areas were tested for significance by pairwise comparisons using Wilcoxon-rank-sum-tests with a significance level α = 5%. Best scores were found at the machined surface areas (SA: 5.58 ± 0.43, NSA: 4.76 ± 1.09), followed by the tips of the threads (SA: 4.29 ± 0.44, NSA: 4.43 ± 0.61), and areas between threads (SA: 3.79 ± 0.89, NSA: 2.42 ± 1.11). Apically facing threads were most difficult to clean (SA: 1.70 ± 0.92, NSA: 2.42 ± 1.11). Here, air powder abrasives provided the best results. Machined surfaces at the implant shoulder were well accessible and showed least amounts of residual stain. Apically facing thread surfaces constituted the area with most residual stain regardless of treatment approach.

  4. Human bone marrow mesenchymal stem cells for retinal vascular injury.

    Science.gov (United States)

    Wang, Jin-Da; An, Ying; Zhang, Jing-Shang; Wan, Xiu-Hua; Jonas, Jost B; Xu, Liang; Zhang, Wei

    2017-09-01

    To examine the potential of intravitreally implanted human bone marrow-derived mesenchymal stem cells (BMSCs) to affect vascular repair and the blood-retina barrier in mice and rats with oxygen-induced retinopathy, diabetic retinopathy or retinal ischaemia-reperfusion damage. Three study groups (oxygen-induced retinopathy group: 18 C57BL/6J mice; diabetic retinopathy group: 15 rats; retinal ischaemia-reperfusion model: 18 rats) received BMSCs injected intravitreally. Control groups (oxygen-induced retinopathy group: 12 C57BL/6J mice; diabetic retinopathy group: 15 rats; retinal ischaemia-reperfusion model: 18 rats) received an intravitreal injection of phosphate-buffered saline. We applied immunohistological techniques to measure retinal vascularization, spectroscopic measurements of intraretinally extravasated fluorescein-conjugated dextran to quantify the blood-retina barrier breakdown, and histomorphometry to assess retinal thickness and retinal ganglion cell count. In the oxygen-induced retinopathy model, the study group with intravitreally injected BMSCs as compared with the control group showed a significantly (p = 0.001) smaller area of retinal neovascularization. In the diabetic retinopathy model, study group and control group did not differ significantly in the amount of intraretinally extravasated dextran. In the retinal ischaemia-reperfusion model, on the 7th day after retina injury, the retina was significantly thicker in the study group than in the control group (p = 0.02), with no significant difference in the retinal ganglion cell count (p = 0.36). Intravitreally implanted human BMSCs were associated with a reduced retinal neovascularization in the oxygen-induced retinopathy model and with a potentially cell preserving effect in the retinal ischaemia-reperfusion model. Intravitreal BMSCs may be of potential interest for the therapy of retinal vascular disorders. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley

  5. Pediatric interventional radiology: vascular interventions

    International Nuclear Information System (INIS)

    Kandasamy, Devasenathipathy; Gamanagatti, Shivanand; Gupta, Arun Kumar

    2016-01-01

    Pediatric interventional radiology (PIR) comprises a range of minimally invasive diagnostic and therapeutic procedures that are performed using image guidance. PIR has emerged as an essential adjunct to various surgical and medical conditions. Over the years, technology has undergone dramatic and continuous evolution, making this speciality grow. In this review, the authors will discuss various vascular interventional procedures undertaken in pediatric patients. It is challenging for the interventional radiologist to accomplish a successful interventional procedure. There are many vascular interventional radiology procedures which are being performed and have changed the way the diseases are managed. Some of the procedures are life saving and have become the treatment of choice in those patients. The future is indeed bright for the practice and practitioners of pediatric vascular and non-vascular interventions. As more and more of the procedures that are currently being performed in adults get gradually adapted for use in the pediatric population, it may be possible to perform safe and successful interventions in many of the pediatric vascular lesions that are otherwise being referred for surgery. (author)

  6. Modified distal revascularization with interval ligation procedure for steal syndrome after arteriovenous fistula creation for hemodialysis access

    NARCIS (Netherlands)

    van der Meer, Saskia; Zeebregts, Clark; Tielliu, Ignacc; Verhoeven, Eric; van den Dungen, Jan

    2007-01-01

    Patients diagnosed with steal syndrome after hemodialysis access surgery have a few options for symptom relief while maintaining vascular access. These include fistula lengthening, banding, distal revascularization with interval ligation (DRIL), revision using distal inflow (RUDI) or proximalization

  7. Unstable patients with retroperitoneal vascular trauma: an endovascular approach.

    Science.gov (United States)

    Boufi, Mourad; Bordon, Sébastien; Dona, Bianca; Hartung, Olivier; Sarran, Anthony; Nadeau, Sébastien; Maurin, Charlotte; Alimi, Yves S

    2011-04-01

    In hemodynamically unstable patients, the management of retroperitoneal vascular trauma is both difficult and challenging. Endovascular techniques have become an alternative to surgery in several trauma centers. Between 2004 and 2006, 16 patients (nine men, mean age: 46 years, range: 19-79 years) with retroperitoneal vascular trauma and hemodynamic instability were treated using an endovascular approach. The mean injury severity score was 30.7 ± 13.1. Mean systolic blood pressure and the shock index were 74 mm Hg and 1.9, respectively. Vasopressor drugs were required in 68.7% of cases (n = 11). Injuries were attributable to road traffic accidents (n = 15) and falls (n = 1). The hemorrhage sites included the internal iliac artery or its branches (n = 12) with bilateral injury in one case, renal artery (n = 2), abdominal aorta (n = 1), and lumbar artery (n = 1). In all, 14 coil embolizations and three stent-grafts were implanted. The technical success rate was 75%, as early re-embolization was necessary in one case and three patients died during the perioperative period. Six patients died during the period of hospitalization (37.5%). No surgical conversion or major morbidity was reported. In comparison with particulates, coil ± stent-graft may provide similar efficacy with regard to survival, and thus may be a valuable solution when particulate embolization is not available or feasible. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  8. Poly-ε-caprolactone Coated and Functionalized Porous Titanium and Magnesium Implants for Enhancing Angiogenesis in Critically Sized Bone Defects.

    Science.gov (United States)

    Roland, Laura; Grau, Michael; Matena, Julia; Teske, Michael; Gieseke, Matthias; Kampmann, Andreas; Beyerbach, Martin; Murua Escobar, Hugo; Haferkamp, Heinz; Gellrich, Nils-Claudius; Nolte, Ingo

    2015-12-22

    For healing of critically sized bone defects, biocompatible and angiogenesis supporting implants are favorable. Murine osteoblasts showed equal proliferation behavior on the polymers poly-ε-caprolactone (PCL) and poly-(3-hydroxybutyrate)/poly-(4-hydroxybutyrate) (P(3HB)/P(4HB)). As vitality was significantly better for PCL, it was chosen as a suitable coating material for further experiments. Titanium implants with 600 µm pore size were evaluated and found to be a good implant material for bone, as primary osteoblasts showed a vitality and proliferation onto the implants comparable to well bottom (WB). Pure porous titanium implants and PCL coated porous titanium implants were compared using Live Cell Imaging (LCI) with Green fluorescent protein (GFP)-osteoblasts. Cell count and cell covered area did not differ between the implants after seven days. To improve ingrowth of blood vessels into porous implants, proangiogenic factors like Vascular Endothelial Growth Factor (VEGF) and High Mobility Group Box 1 (HMGB1) were incorporated into PCL coated, porous titanium and magnesium implants. An angiogenesis assay was performed to establish an in vitro method for evaluating the impact of metallic implants on angiogenesis to reduce and refine animal experiments in future. Incorporated concentrations of proangiogenic factors were probably too low, as they did not lead to any effect. Magnesium implants did not yield evaluable results, as they led to pH increase and subsequent cell death.

  9. Poly-ε-caprolactone Coated and Functionalized Porous Titanium and Magnesium Implants for Enhancing Angiogenesis in Critically Sized Bone Defects

    Directory of Open Access Journals (Sweden)

    Laura Roland

    2015-12-01

    Full Text Available For healing of critically sized bone defects, biocompatible and angiogenesis supporting implants are favorable. Murine osteoblasts showed equal proliferation behavior on the polymers poly-ε-caprolactone (PCL and poly-(3-hydroxybutyrate/poly-(4-hydroxybutyrate (P(3HB/P(4HB. As vitality was significantly better for PCL, it was chosen as a suitable coating material for further experiments. Titanium implants with 600 µm pore size were evaluated and found to be a good implant material for bone, as primary osteoblasts showed a vitality and proliferation onto the implants comparable to well bottom (WB. Pure porous titanium implants and PCL coated porous titanium implants were compared using Live Cell Imaging (LCI with Green fluorescent protein (GFP-osteoblasts. Cell count and cell covered area did not differ between the implants after seven days. To improve ingrowth of blood vessels into porous implants, proangiogenic factors like Vascular Endothelial Growth Factor (VEGF and High Mobility Group Box 1 (HMGB1 were incorporated into PCL coated, porous titanium and magnesium implants. An angiogenesis assay was performed to establish an in vitro method for evaluating the impact of metallic implants on angiogenesis to reduce and refine animal experiments in future. Incorporated concentrations of proangiogenic factors were probably too low, as they did not lead to any effect. Magnesium implants did not yield evaluable results, as they led to pH increase and subsequent cell death.

  10. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  11. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Pedersoli, F., E-mail: fpedersoli@ukaachen.de; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Schmeding, M. [RWTH Aachen University Hospital, Clinic for General, Visceral and Transplant Surgery (Germany); Kuhl, C. K.; Bruners, P. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  12. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Pedersoli, F.; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M.; Schmeding, M.; Kuhl, C. K.; Bruners, P.

    2016-01-01

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  13. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  14. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  15. Fetal origin of vascular aging

    Directory of Open Access Journals (Sweden)

    Shailesh Pitale

    2011-01-01

    Full Text Available Aging is increasingly regarded as an independent risk factor for development of cardiovascular diseases such as atherosclerosis and hypertension and their complications (e.g. MI and Stroke. It is well known that vascular disease evolve over decades with progressive accumulation of cellular and extracellular materials and many inflammatory processes. Metabolic syndrome, obesity and diabetes are conventionally recognized as risk factors for development of coronary vascular disease (CVD. These conditions are known to accelerate ageing process in general and vascular ageing in particular. Adverse events during intrauterine life may programme organ growth and favour disease later in life, popularly known as, ′Barker′s Hypothesis′. The notion of fetal programming implies that during critical periods of prenatal growth, changes in the hormonal and nutritional milieu of the conceptus may alter the full expression of the fetal genome, leading to permanent effects on a range of physiological.

  16. Imaging after vascular gene therapy

    International Nuclear Information System (INIS)

    Manninen, Hannu I.; Yang, Xiaoming

    2005-01-01

    Targets for cardiovascular gene therapy currently include limiting restenosis after balloon angioplasty and stent placement, inhibiting vein bypass graft intimal hyperplasia/stenosis, therapeutic angiogenesis for cardiac and lower-limb ischemia, and prevention of thrombus formation. While catheter angiography is still standard method to follow-up vascular gene transfer, other modern imaging techniques, especially intravascular ultrasound (IVUS), magnetic resonance (MR), and positron emission tomography (PET) imaging provide complementary information about the therapeutic effect of vascular gene transfer in humans. Although molecular imaging of therapeutic gene expression in the vasculatures is still in its technical development phase, it has already offered basic medical science an extremely useful in vivo evaluation tool for non- or minimally invasive imaging of vascular gene therapy

  17. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  18. Vascular Gene Expression: A Hypothesis

    Directory of Open Access Journals (Sweden)

    Angélica Concepción eMartínez-Navarro

    2013-07-01

    Full Text Available The phloem is the conduit through which photoassimilates are distributed from autotrophic to heterotrophic tissues and is involved in the distribution of signaling molecules that coordinate plant growth and responses to the environment. Phloem function depends on the coordinate expression of a large array of genes. We have previously identified conserved motifs in upstream regions of the Arabidopsis genes, encoding the homologs of pumpkin phloem sap mRNAs, displaying expression in vascular tissues. This tissue-specific expression in Arabidopsis is predicted by the overrepresentation of GA/CT-rich motifs in gene promoters. In this work we have searched for common motifs in upstream regions of the homologous genes from plants considered to possess a primitive vascular tissue (a lycophyte, as well as from others that lack a true vascular tissue (a bryophyte, and finally from chlorophytes. Both lycophyte and bryophyte display motifs similar to those found in Arabidopsis with a significantly low E-value, while the chlorophytes showed either a different conserved motif or no conserved motif at all. These results suggest that these same genes are expressed coordinately in non- vascular plants; this coordinate expression may have been one of the prerequisites for the development of conducting tissues in plants. We have also analyzed the phylogeny of conserved proteins that may be involved in phloem function and development. The presence of CmPP16, APL, FT and YDA in chlorophytes suggests the recruitment of ancient regulatory networks for the development of the vascular tissue during evolution while OPS is a novel protein specific to vascular plants.

  19. Phage nanofibers induce vascularized osteogenesis in 3D printed bone scaffolds.

    Science.gov (United States)

    Wang, Jianglin; Yang, Mingying; Zhu, Ye; Wang, Lin; Tomsia, Antoni P; Mao, Chuanbin

    2014-08-06

    A virus-activated matrix is developed to overcome the challenge of forming vascularized bone tissue. It is generated by filling a 3D printed bioceramic scaffold with phage nanofibers displaying high-density RGD peptide. After it is seeded with mesenchymal stem cells (MSCs) and implanted into a bone defect, the phage nanofibers induce osteogenesis and angiogenesis by activating endothelialization and osteogenic differentiation of MSCs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Use of a biodegradable, oversized stent in a child with tracheomalacia secondary to vascular external compression.

    Science.gov (United States)

    Di Dedda, Giovanni; Mirabile, Cristian

    2017-01-01

    We describe the implantation of an absorbable, custom-made stent of polydioxanone to treat tracheomalacia in a 5-month-old patient with extrinsic compression by a double aortic arch. The use of an absorbable, oversized stent treated the tracheal collapse caused by vascular compression, avoided removal procedures, and allowed the infant's growth. The use of an oversized stent prevented stent migration and gave minimal problems of granulation.

  1. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  2. [Vascular Calcification - Pathological Mechanism and Clinical Application - . Role of vascular smooth muscle cells in vascular calcification].

    Science.gov (United States)

    Kurabayashi, Masahiko

    2015-05-01

    Vascular calcification is commonly seen with aging, chronic kidney disese (CKD), diabetes, and atherosclerosis, and is closely associated with cardiovascular morbidity and mortality. Vascular calcification has long been regarded as the final stage of degeneration and necrosis of arterial wall and a passive, unregulated process. However, it is now known to be an active and tightly regulated process involved with phenotypic transition of vascular smooth muscle cells (VSMC) that resembles bone mineralization. Briefly, calcium deposits of atherosclerotic plaque consist of hydroxyapatite and may appear identical to fully formed lamellar bone. By using a genetic fate mapping strategy, VSMC of the vascular media give rise to the majority of the osteochondrogenic precursor- and chondrocyte-like cells observed in the calcified arterial media of MGP (- / -) mice. Osteogenic differentiation of VSMC is characterized by the expression of bone-related molecules including bone morphogenetic protein (BMP) -2, Msx2 and osteopontin, which are produced by osteoblasts and chondrocytes. Our recent findings are that (i) Runx2 and Notch1 induce osteogenic differentiation, and (ii) advanced glycation end-product (AGE) /receptor for AGE (RAGE) and palmitic acid promote osteogenic differentiation of VSMC. To understand of the molecular mechanisms of vascular calcification is now under intensive research area.

  3. Vascular malforma- tions part 1 — normal and abnormal vascular ...

    African Journals Online (AJOL)

    Enrique

    to form the primitive vascular plexus. Angiogenesis is the formation of new vessels by sprouting or splitting of ... The differentiation of primitive vessels into arteries, veins or capillaries is determined by flow patterns .... identify, but it is probable that as time progresses further specific genetic defects related to the development ...

  4. Genetic Regulation of Vascular Development: Building the Zebrafish Vascular Tree

    NARCIS (Netherlands)

    R.L.J.M. Herpers (Robert)

    2010-01-01

    textabstractThe extensive networks of blood and lymphatic vessels within the vertebrate body are essential for the transport and delivery of fluids, gases, macromolecules and cells, and play important roles in facilitating immune responses. The development of the vascular tree requires a highly

  5. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    Science.gov (United States)

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  6. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  7. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  8. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Three-phase bone scintigraphy of hydroxyapatite ocular implants

    International Nuclear Information System (INIS)

    Leitha, T.; Staudenherz, A.; Scholz, U.

    1995-01-01

    Hydroxyapatite ocular implants are replicas of lamellar bone tissue derived from the exoskeleton of a reef-building coral by a hydrothermal chemical exchange reaction. Attached to the eye muscles, they act as a passive framework for fibrovascular ingrowth and can be drilled to hold the visible part of the artificial eye and allow synchronous eye movement. Fibrovascular ingrowth has to be confirmed by bone scintigraphy before the drilling procedure. This study monitored the vascular ingrowth into the implant in ten patients over 12 months to establish a clinically feasible imaging protocol. Tracer accumulation was monitored visually and quantitatively in dynamic and single-photon emission tomography (SPET) scans after the intravenous administration of 600 MBq of 99m Tc-DPD. The implants showed no tracer accumulation in the arterial or blood pool phase. Accordingly, dynamic scintigraphy can be omitted from the imaging protocol. Delayed tracer accumulation appeared no earlier than 2 and no later than 6 months after surgery. Planar scintigraphy is not recommended as high-resolution SPET is necessary to separate the implant from the surrounding bone. We conclude that imaging can be confined to high-resolution SPET 3 h after tracer injection, no earlier than 3 months after surgery. The vascularized hydroxyapatite orbital implant is an important in vivo model for bone-seeking agents to study their uptake kinetics independently of any soft tissue and bone disease. Our results provide evidence that in normal bones the chemical adsorption of 99m Tc-DPD into the crystalline structure of hydroxyapatite is the only quantitatively relevant uptake mechanism. (orig.)

  10. Three-phase bone scintigraphy of hydroxyapatite ocular implants

    Energy Technology Data Exchange (ETDEWEB)

    Leitha, T. [Univ. Clinic of Nuclear Medicine, Univ. of Vienna (Austria); Staudenherz, A. [Univ. Clinic of Nuclear Medicine, Univ. of Vienna (Austria); Scholz, U. [First Univ. Clinic of Ophthalmology, Univ. of Vienna (Austria)

    1995-04-01

    Hydroxyapatite ocular implants are replicas of lamellar bone tissue derived from the exoskeleton of a reef-building coral by a hydrothermal chemical exchange reaction. Attached to the eye muscles, they act as a passive framework for fibrovascular ingrowth and can be drilled to hold the visible part of the artificial eye and allow synchronous eye movement. Fibrovascular ingrowth has to be confirmed by bone scintigraphy before the drilling procedure. This study monitored the vascular ingrowth into the implant in ten patients over 12 months to establish a clinically feasible imaging protocol. Tracer accumulation was monitored visually and quantitatively in dynamic and single-photon emission tomography (SPET) scans after the intravenous administration of 600 MBq of {sup 99m}Tc-DPD. The implants showed no tracer accumulation in the arterial or blood pool phase. Accordingly, dynamic scintigraphy can be omitted from the imaging protocol. Delayed tracer accumulation appeared no earlier than 2 and no later than 6 months after surgery. Planar scintigraphy is not recommended as high-resolution SPET is necessary to separate the implant from the surrounding bone. We conclude that imaging can be confined to high-resolution SPET 3 h after tracer injection, no earlier than 3 months after surgery. The vascularized hydroxyapatite orbital implant is an important in vivo model for bone-seeking agents to study their uptake kinetics independently of any soft tissue and bone disease. Our results provide evidence that in normal bones the chemical adsorption of {sup 99m}Tc-DPD into the crystalline structure of hydroxyapatite is the only quantitatively relevant uptake mechanism. (orig.)

  11. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease

    DEFF Research Database (Denmark)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif

    2013-01-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California).......This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California)....

  12. Fabrication of biosynthetic vascular prostheses by 193-nm excimer laser radiation

    Science.gov (United States)

    Husinsky, Wolfgang; Csek, Ch.; Bartel, A.; Grabenwoeger, M.; Fitzal, F.; Wolner, Ernst

    1998-05-01

    This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (OmniflowTM) through perforations created by an excimer-laser, thus inducing an endothelial cell coverage. The biosynthetic vascular prostheses (10 cm length, 6 mm (phi) ) were perforated with an excimer laser ((phi) of the holes 50 - 100 micrometer, distance 4 mm) and implanted into the carotid arteries of 8 sheep. The laser tissue interaction process of 193 nm radiation ensures minimal thermal damage to the prostheses. They were compared to untreated OmniflowTM prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histological examination and scanning electron microscopy. Scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork and activated platelets formed the inner layer in 6 out of 8 untreated OmniflowTM prostheses. It can be concluded, that spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

  13. Application of a vascular graft material (Solcograft-P) in experimental surgery.

    Science.gov (United States)

    Nemes, A; Acsády, G; Fraefel, W; Lichti, H; Monos, E; Oertli, R; Somogyi, E; Sótonyi, P

    1985-09-01

    The implantation and post-implantation behaviour of a Solcograft-P vascular prosthesis in the aortic, aorto-iliac, carotid and vena caval positions in dogs was studied up to 100 d post-surgery in order to assess the suitability of this vascular material for use in man. Solcograft-P is prepared from the carotid arteries of calves by crosslinking the collagen stroma using adipyl dichloride. During the postoperative follow-up period of 3 month, 100% of the aortal grafts, 80% of the aorto-iliac bypasses, 60% of the vena caval grafts and 35% of the carotid implants remained patent. The biochemical properties of the Solcograft-P are better than those of Solcograft, its predecessor. The intimal lining was consistently smooth and homogeneous in grafts of biological origin, and no aneurysm was observed. Infection and early thrombosis occured no more frequently than with other grafts. The new Solcograft-P, crosslinked via ester and amide groups, seems to represent a real improvement over Solcograft. Our results suggest that Solcograft-P should prove valuable in various cases of reconstructive vascular surgery of the lower limb, especially when the autologous vena saphena magna is not available, and its mechanical properties may well prove suitable for both arterial and venous replacement.

  14. Slim 198gold-grain implanter loaded with standard royal marsden 14-grain magazines

    International Nuclear Information System (INIS)

    Delclos, L.; Moore, E.B.

    1979-01-01

    We designed a slim gold-grain implanter with adaptable lengths to implant areas accessible only through long, narrow, examining instruments, such as a suspension laryngoscope. The implanter is loaded with the same 14-grain magazine designed for and supplied with the Royal Marsden gun. The simplicity of the loading mechanism with a minimum of moving parts makes the instrument practically trouble free. Although it is designed to be used along narrow examining instruments, it can also be used in any situation in which a permanent implant is required, for instance, prostatic cancer and pelvic recurrences in cancer of the uterine cervix previously treated by external and intracavitary irradiation

  15. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  16. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  17. Adventitial gene transfer of catalase attenuates angiotensin II-induced vascular remodeling.

    Science.gov (United States)

    Liu, Cun-Fei; Zhang, Jia; Shen, Kai; Gao, Ping-Jin; Wang, Hai-Ya; Jin, Xin; Meng, Chao; Fang, Ning-Yuan

    2015-04-01

    Vascular adventitia and adventitia‑derived reactive oxygen species (ROS) contribute to vascular remodeling following vascular injury. A previous ex vivo study in adventitial fibroblasts showed that catalase, one of most important anti‑oxide enzymes, was downregulated by angiotensin II (AngII). The aim of the present study was to investigate whether adventitial gene transfer of catalase affects AngII‑induced vascular remodeling in vivo. Adenoviruses co‑expressing catalase and enhanced green fluorescent protein (eGFP) or expressing eGFP only were applied to the adventitial surface of common carotid arteries of Sprague‑Dawley rats. Alzet minipumps administering AngII (0.75 mg/kg/day) were then implanted subcutaneously for 14 days. Systolic blood pressure and biological parameters of vascular remodeling were measured in each group. Adventitial fibroblasts were cultured and p38 mitogen‑activated protein kinase (MAPK) phosphorylation was measured using western blot analysis. The results showed that adventitial gene transfer of catalase had no effect on AngII‑induced systolic blood pressure elevation. However, catalase adenovirus transfection significantly inhibited AngII‑induced media hypertrophy compared with that of the control virus (Padventitial α‑smooth muscle actin expression. Furthermore, catalase transfection significantly inhibited the AngII‑induced increase in p38MAPK phosphorylation. In conclusion, the results of the present study demonstrated that adventitial gene transfer of catalase significantly attenuated AngII‑induced vascular remodeling in rats via inhibition of adventitial p38MAPK phosphorylation.

  18. Biocompatibility and biodegradation studies of subconjunctival implants in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Yan Peng

    Full Text Available Sustained ocular drug delivery is difficult to achieve. Most drugs have poor penetration due to the multiple physiological barriers of the eye and are rapidly cleared if applied topically. Biodegradable subconjunctival implants with controlled drug release may circumvent these two problems. In our study, two microfilms (poly [d,l-lactide-co-glycolide] PLGA and poly[d,l-lactide-co-caprolactone] PLC were developed and evaluated for their degradation behavior in vitro and in vivo. We also evaluated the biocompatibility of both microfilms. Eighteen eyes (9 rabbits were surgically implanted with one type of microfilm in each eye. Serial anterior-segment optical coherence tomography (AS-OCT scans together with serial slit-lamp microscopy allowed us to measure thickness and cross-sectional area of the microfilms. In vitro studies revealed bulk degradation kinetics for both microfilms, while in vivo studies demonstrated surface erosion kinetics. Serial slit-lamp microscopy revealed no significant inflammation or vascularization in both types of implants (mean increase in vascularity grade PLGA50/50 12±0.5% vs. PLC70/30 15±0.6%; P = 0.91 over a period of 6 months. Histology, immunohistochemistry and immuno-fluorescence also revealed no significant inflammatory reaction from either of the microfilms, which confirmed that both microfilms are biocompatible. The duration of the drug delivery can be tailored by selecting the materials, which have different degradation kinetics, to suit the desired clinical therapeutic application.

  19. Image Quality in Vascular Radiology

    International Nuclear Information System (INIS)

    Vanhavere, F.; Struelens, L.

    2005-01-01

    In vascular radiology, the radiologists use the radiological image to diagnose or treat a specific vascular structure. From literature, we know that related doses are high and that large dose variability exists between different hospitals. The application of the optimization principle is therefore necessary and is obliged by the new legislation. So far, very little fieldwork has been performed and no practical instructions are available to do the necessary work. It's indisputable that obtaining quantitative data is of great interest for optimization purposes. In order to gain insight into these doses and the possible measures for dose reduction, we performed a comparative study in 7 hospitals. Patient doses will be measured and calculated for specific procedures in vascular radiology and evaluated against their most influencing parameters. In view of optimization purposes, a protocol for dose audit will be set-up. From the results and conclusions in this study, experimentally based guidelines will be proposed, in order to improve clinical practice in vascular radiology

  20. Vascular aspects of multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, Miguel; Cambron, Melissa; Vanopdenbosch, Ludo; De Keyser, Jacques

    Three types of vascular dysfunction have been described in multiple sclerosis (MS). First, findings from epidemiological studies suggest that patients with MS have a higher risk for ischaemic stroke than people who do not have MS. The underlying mechanism is unknown, but might involve endothelial

  1. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  2. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  3. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  4. Minimally invasive basilic vein transposition in the arm or forearm for autogenous haemodialysis access: A less morbid alternative to the conventional technique

    Directory of Open Access Journals (Sweden)

    Ankush Jairath

    2017-06-01

    Conclusion: Minimally invasive dissection of the basilic vein for vascular access transposition is a safe, reliable procedure with patency and functional outcomes comparable with those of conventional BVT.

  5. Tissue engineered vascular grafts: Origins, development, and current strategies for clinical application.

    Science.gov (United States)

    Benrashid, Ehsan; McCoy, Christopher C; Youngwirth, Linda M; Kim, Jina; Manson, Roberto J; Otto, James C; Lawson, Jeffrey H

    2016-04-15

    Since the development of a dependable and durable synthetic non-autogenous vascular conduit in the mid-twentieth century, the field of vascular surgery has experienced tremendous growth. Concomitant with this growth, development in the field of bioengineering and the development of different tissue engineering techniques have expanded the armamentarium of the surgeon for treating a variety of complex cardiovascular diseases. The recent development of completely tissue engineered vascular conduits that can be implanted for clinical application is a particularly exciting development in this field. With the rapid advances in the field of tissue engineering, the great hope of the surgeon remains that this conduit will function like a true blood vessel with an intact endothelial layer, with the ability to respond to endogenous vasoactive compounds. Eventually, these engineered tissues may have the potential to supplant older organic but not truly biologic technologies, which are used currently. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Computer tomography valorization of the vascular lingual channels in the jaw

    International Nuclear Information System (INIS)

    Costantino, Sebastian; Capiel, Carlos h; Bouzas, Carlos; Vuotto, Miguel; Ferrari, Daniela; Bazzano, Sebastian

    2006-01-01

    Purpose: To determine the frequency, location and position of vascular lingual channels of jaw by dental CT and classifying them based on its location. Material and methods: Dental CT of 100 consecutive patients were reevaluated as previous evaluation to the positioning of dental implants. They are classified by linking their location on the jaw with the number of tooth present or absent in that area. Results: All patients had at least one lingual vascular channel in the jaw; 36 patients presented two channels, eight patients presented three and a patient presented four. The more frequent location was between the sectors of the pieces 31 and 41. Sixteen patients showed two channels (superior and inferior) in that location. The second location by frequency was between pieces 32 and 33 (nine patients). The average distance between the lingual surface of the alveolar rim and the vascular channels was of 16 mm. Conclusion: the dental CT is an excellent method for the identification of the vascular lingual channels by its multiplanar capacity and appropriate image resolution. The characterization and classification of these conduits by a method of easy reading for the radiologists and the dentists assure a correct pre surgical valuation avoiding hemorrhages during the jaw perforation in the positioning of dental implants. (author) [es

  7. Improvement of cell infiltration in electrospun polycaprolactone scaffolds for the construction of vascular grafts.

    Science.gov (United States)

    Wang, Kai; Zhu, Meifeng; Li, Ting; Zheng, Wenting; Li, Li; Xu, Mian; Zhao, Qiang; Kong, Deling; Wang, Lianyong

    2014-08-01

    The less-than-ideal cell infiltration resulting from inherently small pore size limits the application of electrospinning scaffold in tissue engineering and regeneration medicine. The present study aims to develop a porogenic method which can significantly increase pore size in electrospinning scaffold and enhance cell migration. With this method, composite scaffolds consisting of poly(epsilon-caprolactone) (PCL) fibers and poly(ethylene oxide) (PEO) microparticles were prepared by simultaneously electrospinning and electrospraying. Removal of the PEO microparticles from the composites generated large pores. In vitro culture of NIH3T3 cells and in vivo subcutaneous implantation both demonstrated that the porogenic scaffolds markedly facilitated cell infiltration. With the same technique, vascular grafts with alternative dense and loose layers were prepared by turning on or off electrospraying PEO. SEM showed that there was no a clear delamination between the loose and dense layers. The mechanical strength and burst pressure of these vascular grafts could meet the requirements of vascular implantation. In conclusion, electrospinning PCL fibers with electrospraying PEO microparticles may be an effective and controllable method to increase pore size in electrospinning scaffold and provides a useful tool for the fabrication of vascular grafts that meets the need of blood vessel replacement.

  8. Prominent Vascularization Capacity of Mesenchymal Stem Cells in Collagen-Gold Nanocomposites.

    Science.gov (United States)

    Hsieh, Shu-Chen; Chen, Hui-Jye; Hsu, Shan-Hui; Yang, Yi-Chin; Tang, Cheng-Ming; Chu, Mei-Yun; Lin, Pei-Ying; Fu, Ru-Huei; Kung, Mei-Lang; Chen, Yun-Wen; Yeh, Bi-Wen; Hung, Huey-Shan

    2016-10-26

    The ideal characteristics of surface modification on the vascular graft for clinical application would be with excellent hemocompatibility, endothelialization capacity, and antirestenosis ability. Here, Fourier transform infrared spectroscopy (FTIR), surface enhanced Raman spectroscopy (SERS), atomic force microscopy (AFM), contact angle (θ) measurement, and thermogravimetric analysis (TGA) were used to evaluate the chemical and mechanical properties of collagen-gold nanocomposites (collagen+Au) with 17.4, 43.5, and 174 ppm of Au and suggested that the collagen+Au with 43.5 ppm of Au had better biomechanical properties and thermal stability than pure collagen. Besides, stromal-derived factor-1α (SDF-1α) at 50 ng/mL promoted the migration of mesenchymal stem cells (MSCs) on collagen+Au material through the α5β3 integrin/endothelial oxide synthase (eNOS)/metalloproteinase (MMP) signaling pathway which can be abolished by the knockdown of vascular endothelial growth factor (VEGF). The potentiality of collagen+Au with MSCs for vascular regeneration was evaluated by our in vivo rat model system. Artery tissues isolated from an implanted collagen+Au-coated catheter with MSCs expressed substantial CD-31 and α-SMA, displayed higher antifibrotic ability, antithrombotic activity, as well as anti-inflammatory response than all other materials. Our results indicated that the implantation of collagen+Au-coated catheters with MSCs could be a promising strategy for vascular regeneration.

  9. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  10. Experimental Assessment of a New Type of Carbon-Coated ARTECOR® Vascular Prosthesis in Sheep

    Directory of Open Access Journals (Sweden)

    Jiří Podlaha

    2009-01-01

    Full Text Available The aim of the study was to test and verify the ch