WorldWideScience

Sample records for impaction grafting technique

  1. Impact of bone graft harvesting techniques on bone formation and graft resorption

    DEFF Research Database (Denmark)

    Saulacic, Nikola; Bosshardt, Dieter D; Jensen, Simon S

    2015-01-01

    BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone fo......: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption.......BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone...... formation and graft resorption in vivo. MATERIAL AND METHODS: Four harvesting techniques were used: (i) corticocancellous blocks particulated by a bone mill; (ii) bone scraper; (iii) piezosurgery; and (iv) bone slurry collected from a filter device upon drilling. The grafts were placed into bone defects...

  2. Femoral component revision with use of impaction bone-grafting and a cemented polished stem. Surgical technique.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2006-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  3. SOME TECHNIQUES IN CORNEAL GRAFTING

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... current herpes corneae. The visual acuity was less than. 6/60. The left eye had had a central nebula since child- hood and was deemed amblyopic. Six weeks after a 7 x 0·3 mm lamellar graft in the right eye was placed, ulceration occurred in the graft junction. A total thin conjunctival flap was sutured over.

  4. A novel technique for impaction bone grafting in acetabular reconstruction of revision total hip arthroplasty using an ex vivo compaction device

    International Nuclear Information System (INIS)

    Akiyama, Haruhiko; Takemoto, Mitsuru; Morishima, Takkan

    2011-01-01

    Impaction bone grafting allows restoration of the acetabular bone stock in revision hip arthroplasty. The success of this technique depends largely on achieving adequate initial stability of the component. To obtain well-compacted, well-graded allograft aggregates, we developed an ex vivo compaction device to apply it in revision total hip arthroplasty on the acetabular side, and characterized mechanical properties and putative osteoconductivity of allograft aggregates. Morselized allograft bone chips were compacted ex vivo using the creep technique and subsequent impaction technique to form the bone aggregates. Impaction allograft reconstruction of the acetabulum using an ex vivo compaction device was performed on eight hips. The mechanical properties and three-dimensional micro-CT-based structural characteristics of the bone aggregates were investigated. In clinical practice, this technique offered good reproducibility in reconstructing the cavity and the segmental defects of the acetabulum, with no migration and no loosening of the component. In vitro analysis showed that the aggregates generated from 25 g fresh-frozen bone chips gained compression stiffness of 13.5-15.4 MPa under uniaxial consolidation strain. The recoil of the aggregates after compaction was 2.6-3.9%. The compression stiffness and the recoil did not differ significantly from those measured using a variety of proportions of large- and small-sized bone chips. Micro-CT-based structural analysis revealed average pore sizes of 268-299 μm and average throat diameter of pores in the bone aggregates of more than 100 μm. These sizes are desirable for osteoconduction, although large interconnected pores of more than 500 μm were detectable in association with the proportion of large-sized bone chips. Cement penetration into the aggregates was related to the proportion of large-sized bone chips. This study introduces the value of an ex vivo compaction device in bone graft compaction in clinical

  5. Excellent Aesthetic and Functional Outcome After Fractionated Carbon Dioxide Laser Skin Graft Revision Surgery: Case Report and Review of Laser Skin Graft Revision Techniques.

    Science.gov (United States)

    Ho, Derek; Jagdeo, Jared

    2015-11-01

    Skin grafts are utilized in dermatology to reconstruct a defect secondary to surgery or trauma of the skin. Common indications for skin grafts include surgical removal of cutaneous malignancies, replacement of tissue after burns or lacerations, and hair transplantation in alopecia. Skin grafts may be cosmetically displeasing, functionally limiting, and significantly impact patient's quality-of-life. There is limited published data regarding skin graft revision to enhance aesthetics and function. Here, we present a case demonstrating excellent aesthetic and functional outcome after fractionated carbon dioxide (CO2) laser skin graft revision surgery and review of the medical literature on laser skin graft revision techniques.

  6. A multilayered polyurethane foam technique for skin graft immobilization.

    Science.gov (United States)

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (skin graft. This multilayered polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  7. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  8. Development of Highly Efficient Grafting Technique and Synthesis of Natural Polymer-Based Graft Adsorbent

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Y; Seko, N; Tamada, M [Japan Atomic Energy Agency, Quantum Beam Science Directorate, Takasaki (Japan)

    2012-09-15

    In the framework of the CRP, Japan has focused on the development of fibrous adsorbents for removal of toxic metal ions and recovery of significant metal ions from industrial wastewater and streaming water. Graft polymerization was carried out by using gamma irradiation facility and electron beam accelerator. Emulsion grafting is a novel topic for synthesis of metal ion adsorbents which are prepared from fibrous trunk polymers such as polyethylene fibre and biodegradable nonwoven fabrics. The emulsion grafting, where monomer micelles are dispersed in water in the presence of surfactant, is a highly efficient and economic grafting technique as compared to general organic solvent system. The resultant cotton-based adsorbent has high adsorption efficiency and high adsorption capacity for Hg, besides, it is biodegradable. Polylactic acid can also be used as a trunk material for the grafting. (author)

  9. Grafting: a technique to modify ion accumulation in horticultural crops

    Directory of Open Access Journals (Sweden)

    Muhammad Azher Nawaz

    2016-10-01

    Full Text Available Grafting is a centuries-old technique used in plants to obtain economic benefits. Grafting increases nutrient uptake and utilization efficiency in a number of plant species, including fruits, vegetables, and ornamentals. Selected rootstocks of the same species or close relatives are utilized in grafting. Rootstocks absorb more water and ions than self-rooted plants and transport these water and ions to the aboveground scion. Ion uptake is regulated by a complex communication mechanism between the scion and rootstock. Sugars, hormones, and miRNAs function as long-distance signaling molecules and regulate ion uptake and ion homeostasis by affecting the activity of ion transporters. This review summarizes available information on the effect of rootstock on nutrient uptake and utilization and the mechanisms involved. Information on specific nutrient-efficient rootstocks for different crops of commercial importance is also provided. Several other important approaches, such as interstocking (during double grafting, inarching, use of plant-growth-promoting rhizobacteria, use of arbuscular mycorrhizal fungi, use of plant growth substances (e.g., auxin and melatonin, and use of genetically engineered rootstocks and scions (transgrafting, are highlighted; these approaches can be combined with grafting to enhance nutrient uptake and utilization in commercially important plant species. Whether the rootstock and scion affect each other’s soil microbiota and their effect on the nutrient absorption of rootstocks remain largely unknown. Similarly, the physiological and molecular bases of grafting, crease formation, and incompatibility are not fully identified and require investigation. Grafting in horticultural crops can help reveal the basic biology of grafting, the reasons for incompatibility, sensing, and signaling of nutrients, ion uptake and transport, and the mechanism of heavy metal accumulation and restriction in rootstocks. Ion transporter and mi

  10. A new grafting technique for tympanoplasty: tympanoplasty with a boomerang-shaped chondroperichondrial graft (TwBSCPG).

    Science.gov (United States)

    Dündar, Rıza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal

    2014-10-01

    The aim of this study was to introduce a new grafting technique in tympanoplasty that involves use of a boomerang-shaped chondroperichondrial graft (BSCPG). The anatomical and functional results were evaluated. A new tympanoplasty with boomerang-shaped chondroperichondrial graft (TwBSCPG) technique was used in 99 chronic otitis media patients with central or marginal perforation of the tympanic membrane and a normal middle ear mucosa. All 99 patients received chondroperichondrial cartilage grafts with a boomerang-shaped cartilage island left at the anterior and inferior parts. Postoperative follow-ups were conducted at months 1, 6, and 12. Preoperative and postoperative audiological examinations were performed and air-bone gaps were calculated according to the pure-tone averages (PTAs) of the patients. In the preoperative period, most (83.8%) air-bone gaps were ≥ 16 dB; after operating using the TwBSCPG technique, the air-bone gaps decreased to 0-10 dB in most patients (77.8%). In the TwBSCPG patients, the mean preoperative air-bone gap was 22.02 ± 6.74 dB SPL. Postoperatively, the mean postoperative air-bone gap was 8.70 ± 5.74 dB SPL. The TwBSCPG technique therefore decreased the postoperative air-bone gap compared to that preoperatively (p = 0.000, z = -8.645). At the 1-month follow-up, there were six graft perforations and one graft retraction. At the 6-month follow-up, there were nine graft perforations and three graft retractions. At 12 months, there were seven graft perforations and four graft retractions. During the first year after the boomerang tympanoplasty surgery, graft lateralization was not detected in any patient. Retractions were grade 1 according to the Sade classification and were localized to the postero-superior quadrant of the tympanic membrane. The TwBSCPG technique has benefits with respect to postoperative anatomical and audiological results. It prevents perforation of the tympanic membrane at the anterior quadrant and avoids graft

  11. Graft copolymerization of glycidyl methacrylate onto delignified kenaf fibers through pre-irradiation technique

    International Nuclear Information System (INIS)

    Sharif, Jamaliah; Mohamad, Siti Fatahiyah; Fatimah Othman, Nor Azilah; Bakaruddin, Nurul Azra; Osman, Hasnul Nizam; Güven, Olgun

    2013-01-01

    Glycidyl methacrylate grafted kenaf (GMA-g-Kenaf) was prepared by pre-irradiation grafting technique. Kenaf fibers were treated with different concentration of sodium chlorite solution before used as trunk polymer. Treated kenaf fibers were irradiated by electron beam followed by grafting reaction in GMA/water emulsion system. The degree of grafting was determined as a function of absorbed dose, reaction time, reaction temperature and concentration of monomer. The results showed that the lignin content was decreased from 14.3% to as low as 3.3% with the increased of sodium chlorite concentration. This was evidenced by SEM pictures which show the surface of treated kenaf fibers was cleaner and smoother compared to that of untreated one. The degree of grafting increased with the increase of absorbed dose, reaction temperature, reaction time and monomer concentration as well as with decreasing lignin content. Formation of graft copolymer was confirmed with SEM, FTIR analysis. The structural investigation by XRD showed that degree of crystallinity of graft copolymers decreased with the increase in degree of grafting. - Highlights: • We used kenaf fibers for radiation induce graft copolymerization with GMA. • Kenaf fibers was treated to remove lignin in order to increase grafting yield. • Treated kenaf fibers were graft copolymerize through preirradiation technique. • Optimum conditions for graft copolymerization of kenaf fibers were established. • Formation of graft copolymer is also confirmed with SEM, FTIR and XRD

  12. Femoral component revision with use of impaction bone-grafting and a cemented polished stem.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2005-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  13. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    Directory of Open Access Journals (Sweden)

    Hirpara Kieran M

    2011-07-01

    Full Text Available Abstract Background Tensioning of anterior cruciate ligament (ACL reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  14. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    LENUS (Irish Health Repository)

    O'Neill, Barry J

    2011-07-20

    Abstract Background Tensioning of anterior cruciate ligament (ACL) reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  15. Preparation of Dimethylaminoethylmethacrylate Grafted Polymeric Adsorbent by Using Radiation-Induced Grafting Technique for Removal of Anions

    International Nuclear Information System (INIS)

    Kavakli, P. A.

    2006-01-01

    The development of efficient separation and purification techniques is very important from industrial, environmental and economic points of view. Polymeric materials having polyfunctional groups such as carboxylic, amide, nitrile, iminodiacetic acid, amidoxime, and ammonium groups, etc., not only possess good hydrophilic properties, but also have good ion exchange properties which make them suitable for metal recovery from aqueous solutions. Radiation induced grafting is a powerful technique capable of controlling the introduction of various functional groups to the polymeric materials, keeping the original properties and especially the mechanical strength of the base material, and thus, allowing the synthesis of more stable polymeric adsorbents. The main objective of this study was to develop special polymeric adsorbents to remove NOx and PO 4 anions from aqueous systems. For this purpose, a novel nonwoven fabric was prepared by radiation-induced graft polymerization of imethylaminoethylmethacrylate (DMAEMA) onto polypropylene coated polyethylene nonwoven fabric. The trunk polymer was irradiated by electron beam at a voltage of 2 MeV and a current of 3 mA in a nitrogen atmosphere at dry-ice temperature at different doses. The degree of grafting was determined as a function of the total dose, monomer concentration, temperature, and reaction time. It was found that the degree of grafting of grafted polymer was greatly affected by reaction conditions. Grafting conditions were optimized, and about 150 % degree of grafting samples was used for further experiments. DMAEMA grafted polymer was later protonated by using acid solution to prepare adsorbent for the removal of anions. Adsorption experiments were performed in column mode for removal of phosphate. Approximately 2000 bed volumes of phosphate-free water can be produced from 10 ppb phosphate solution at high space velocity

  16. The impact of slow graft function on graft outcome is comparable to delayed graft function in deceased donor kidney transplantation.

    Science.gov (United States)

    Shin, Jung-Ho; Koo, Eun Hee; Ha, Sung Hae; Park, Ji Hyeon; Jang, Hye Ryoun; Lee, Jung Eun; Park, Jae-Berm; Kim, Sung Joo; Jung, Sin-Ho; Kim, Yoon-Goo; Kim, Dae Joong; Oh, Ha Young; Huh, Wooseong

    2016-03-01

    Slow graft function (SGF) can influence overall prognosis in patients receiving deceased donor kidney transplantation (DKT). However, the impact of SGF on renal function remains uncertain. We investigated retrospectively renal function in cases with SGF compared with early graft function (EGF) and delayed graft function (DGF). Renal function after transplantation was analyzed in 199 patients who underwent DKT. Patients were classified into 130 (65.3 %) cases with EGF, 27 (13.6 %) cases with SGF, 6 (3.0 %) cases with DGF and one dialysis (DGF1), and 36 (18.1 %) cases with DGF and two or more dialyses (DGF2). The 1-year estimated glomerular filtration rate (eGFR) in the SGF group was lower than that in the EGF group (P = 0.027), but the rate of eGFR decline did not differ between the groups. The risk factors for renal function were evaluated using the area under the eGFR curve over 3 years (AUCeGFR). Donor age was negatively, and recipient age and the number of HLA matches were positively correlated with the AUCeGFR (all P DKT. Moreover, it was comparable to DGF. Efforts should be dedicated to minimizing the development of SGF and DGF.

  17. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  18. Modification of natural leather by grafting emulsion copolymerization technique

    International Nuclear Information System (INIS)

    Badran, A.S.; Nasr, H.E.; El-Halawany, N.R.; Mohamed, W.S.

    2005-01-01

    Grafting emulsion copolymerization of methyl methacrylate (MMA) with butyl acrylate of different molar ratios onto natural leather with different molar ratios was carried out using developed redox initiation system of potassium persulphate (PPS) as an oxidizing agent and some sodium bisulphite adducts as reducing agent, as well as sodium dodecyl sulphate (SDS) was used as an anionic emulsifier. The grafted leather was characterized via FTIR, SEM and thermal gravimetric analysis. Moreover, the grafted leather was evaluated through water absorption, tensile strength, dyeing performance and hardness measurements. The obtained results revealed that the physical and mechanical properties of the modified leather were enhanced

  19. Characterisation of Microbial Cellulose Modified by Graft Copolymerization Technique

    International Nuclear Information System (INIS)

    Tita Puspitasari; Cynthia Linaya Radiman

    2008-01-01

    Chemical and phisycal modifications of polymer can be carried out by radiation induced graft copolymerization. This research was carried out to study the morphology and crystallinity of microbial cellulose copolymer grafted by acrylic acid (MC-g-AAC). The SEM microstructural analysis proved that the acrylic acid could diffuse into the microbial celullose and resulted a dense structure. Crystallinity measurement showded that the crystalinity of microbial cellulose increase from 50 % to 53 % after modification. (author)

  20. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    Science.gov (United States)

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Use of a Barbed Suture Tie-Over Technique for Skin Graft Dressings: A Case Series

    Directory of Open Access Journals (Sweden)

    Kenneth M Joyce

    2015-05-01

    Full Text Available BackgroundA tie-over dressing is the accepted method to secure skin grafts in order to prevent haematoma or seroma formation. We describe the novel application of a barbed suture tie-over for skin graft dressing. The barbs act as anchors in the skin so constant tensioning of the suture is not required.MethodsFrom January 2014 to August 2014 we used the technique in 30 patients with skin defects requiring split-thickness or full-thickness grafts. Patient demographics, clinicopathological details and graft outcome were collected prospectively.ResultsThe majority of cases were carried out for split-thickness skin grafts (n=19 used on the lower limb (n=20. The results of this novel technique were excellent with complete (100% graft take in all patients.ConclusionsOur results demonstrate the clinical application of a barbed device for securing skin grafts with excellent results. We find the technique quick to perform and the barbed device easy to handle, which can be applied without the need for an assistant.

  2. A Newly‑devised Technique for the Fixation of Mesh Skin Graft

    African Journals Online (AJOL)

    went skin graft using this technique. The ages ranged from. 9 months to 86 years (mean = 62.3 years). The skin defects included two burn ulcers, two decubitus, and 10 chronic leg ulcers. The size of the defects ranged from 20 cm2 to. 210 cm2. All grafts were accepted without complications. A 72-year-old man with a chronic ...

  3. Tumescent Anethesia : A Useful Technique For Harvesting Split- Thickness Skin Graft

    Directory of Open Access Journals (Sweden)

    Saraf Sanjay

    2004-01-01

    Full Text Available Tumescent anesthesia is a now an established technique for regional anesthesia of the skin and the subcutaneous fatty tissue. The unsurpassed simplicity and safely of this procedure have opened up the gates for newer indications. We have employed this technique for harvesting split-thickness grafts in various conditions. We have found that this technique is extremely simple in which large areas can be anesthetized for harvesting split-thickness skin grafts safely. The good passive resistance achieved facilitates easy harvesting of split-thickness grafts along with minimal bleeding and long lasting pain relief. We found this to be an inexpensive, safe and simple technique with elimination of risks and expenses of general anesthesia.

  4. Bone grafting in surgery about the foot and ankle: indications and techniques.

    Science.gov (United States)

    Fitzgibbons, Timothy C; Hawks, Michael A; McMullen, Scott T; Inda, David J

    2011-02-01

    Bone grafting is a common procedure in foot and ankle surgery. Historically, autogenous bone graft has most often been harvested from the ipsilateral iliac crest. However, other sites offer similar volumes of cancellous bone and are associated with fewer complications. The ipsilateral proximal tibia, distal tibia, and calcaneus provide adequate amounts of bone graft material for most arthrodesis procedures about the foot and ankle. Emerging techniques have enabled the development of a seemingly unlimited supply of alternative bone graft materials with osteoconductive properties. The osteoprogenitor cells in bone marrow aspirates can be concentrated by use of selective retention systems. These aspirate-matrix composites may be combined with allograft preparations, resulting in a product that promotes osteoconduction, osteoinduction, and osteogenesis with limited morbidity.

  5. Reconstruction of the Shallow Acetabulum With a Combination of Autologous Bulk and Impaction Bone Grafting Fixed by Cement.

    Science.gov (United States)

    Maruyama, Masaaki; Wakabayashi, Shinji; Ota, Hiroshi; Tensho, Keiji

    2017-02-01

    Acetabular bone deficiency, especially proximal and lateral deficiency, is a difficult technical problem during primary total hip arthroplasty (THA) in developmental dysplasia of the hip (DDH). We report a new reconstruction method using a medial-reduced cemented socket and additional bulk bone in conjunction with impaction morselized bone grafting (additional bulk bone grafting method). In a population of patients with acetabular dysplasia undergoing THA using a medial-reduced cemented socket and additional bulk bone with impacted morselized bone grafting, we evaluated (1) the radiographic appearance of bone graft; (2) the proportion of cups that developed loosening and subsequent revision; and (3) clinical results (outcome scores and complications). Forty percent of 330 THAs for DDH performed at one center between 1999 and 2009 were defined as shallow dysplastic hips. The additional bulk bone grafting method was performed on 102 THAs with shallow acetabulum (31% for DDH) at one center between 1999 and 2009. We used this approach and technique for shallow acetabuli when a cup protruded from the lateral acetabular edge in preoperative templating. The other 132 dysplastic hips without bone grafting had THA performed at the same periods and served as a control. Acetabuli were defined as shallow when the depth was less than or equal to one-fifth of the pelvic height (cranial-caudal length on radiograph). The additional bulk bone grafting technique was as follows: the resected femoral head was sectioned at 1 to 2 cm thickness, and a suitable size of the bulk bone graft was placed on the lateral iliac cortex and fixed by poly-L-lactate absorbable screws. Autologous impaction morselized bone grafting, with or without hydroxyapatite granules, was performed along with the implantation of a medial-reduced cemented socket. We defined an "incorporated" graft as remodeling and trabeculation including rounding off of the protruding edge of a graft beyond the socket

  6. Development of Styrene-Grafted Polyurethane by Radiation-Based Techniques

    Directory of Open Access Journals (Sweden)

    Jin-Oh Jeong

    2016-06-01

    Full Text Available Polyurethane (PU is the fifth most common polymer in the general consumer market, following Polypropylene (PP, Polyethylene (PE, Polyvinyl chloride (PVC, and Polystyrene (PS, and the most common polymer for thermosetting resins. In particular, polyurethane has excellent hardness and heat resistance, is a widely used material for electronic products and automotive parts, and can be used to create products of various physical properties, including rigid and flexible foams, films, and fibers. However, the use of polar polymer polyurethane as an impact modifier of non-polar polymers is limited due to poor combustion resistance and impact resistance. In this study, we used gamma irradiation at 25 and 50 kGy to introduce the styrene of hydrophobic monomer on the polyurethane as an impact modifier of the non-polar polymer. To verify grafted styrene, we confirmed the phenyl group of styrene at 690 cm−1 by Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR and at 6.4–6.8 ppm by 1H-Nuclear Magnetic Resonance (1H-NMR. Scanning Electron Microscope (SEM, X-ray Photoelectron Spectroscopy (XPS, Thermogravimetric Analysis (TGA and contact angle analysis were also used to confirm styrene introduction. This study has confirmed the possibility of applying high-functional composite through radiation-based techniques.

  7. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  8. Radiation-grafted hydrogels for biomaterial applications as studied by the ESCA technique

    International Nuclear Information System (INIS)

    Ratner, B.D.; Weathersby, P.K.; Hoffman, A.S.; Kelly, M.A.; Schrapen, L.H.

    1978-01-01

    Electron spectroscopy for chemical analysis (ESCA) was used to study the surface composition of several radiation-grafted polymers in both the dry and hydrated (frozen at 160 0 K) states. Poly(2-hydroxyethyl methacrylate) (HEMA) and polyacrylamide, both hydrophilic polymers, were readily detected in the hydrated or dehydrated states when grafted to polethylene substrates. For silicone rubber substrates, both grafts were observed on the hydrated surface but were significantly decreased in surface concentration upon dehydration. For grafts on a polyester-urethane, acrylamide was not a major constituent of either the dry or hydrated surface, while HEMA appeared to increase in abundance upon drying. The amount of the hydrophobic poly(ethyl methacrylate) found on the graft surface depended upon the substrate polymer used, but the surface abundance of poly(ethyl methacrylate) was not affected by drying. These results were considered in terms of polar group orientation, polymer chain mobility, substrate permeability, and the limitations of the ESCA technique. The implications of these results with respect to the use of radiation-grafted hydrophilic polymers for biomedical applications are also discussed

  9. Management of Chronic Recurrent Dislocation of Temporomandibular Joint Using 'U' Shaped Graft: A New Restrictive Technique.

    Science.gov (United States)

    Gadre, Kiran; Singh, Divya; Gadre, Pushkar; Halli, Rajshekhar

    2017-06-01

    Numerous procedures have been described for the treatment of chronic recurrent dislocation of the temporo-mandibular joint (TMJ), either in the form of enhancement or restriction of the condylar movement, with their obvious merits and demerits. We present a new technique of using U shaped iliac bone graft to restrict the condylar movement and its advantages over the conventional techniques.We have used this technique successfully in 8 cases where Dautrey's procedure had failed with follow up period of 2 years. No patient complained of recurrent dislocation postoperatively. This a very simple and effective technique where other procedures have failed.

  10. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  11. Full-thickness skin mesh graft vaginoplasty: a skin sparing technique

    Directory of Open Access Journals (Sweden)

    Guilherme Lang Motta

    Full Text Available ABSTRACT Introduction: The ideal vaginoplasty method should promote good cosmetic and functional results with low morbidity. We describe a new technique for congenital vaginal agenesis using a full-thickness perforated skin graft. Materials and Methods: We report an 18 year old patient with vaginal agenesis (Morris syndrome that undergone a modified version of McIndoe vaginoplasty. Patient is set in a low lithotomy position and lateral traction sutures are placed in labia and a 16Fr urethral catheter inserted. An inverted “V”-shaped incision is made in the mucosal plaque below the urethra. Blunt dissection in a cephalic posterior direction forms a space between the rectum and urethra. Special care is taken to avoid rectal tear during this maneuver. A full-thickness skin graft is removed from the lower abdomen measuring 12.0×6.0cm as an aesthetic abdominoplasty. The fat tissue is removed, remaining epidermis and dermis and the graft is perforated, allowing a great surface increase. After suturing over a mold, the graft is fixed in the created space. The donor site is closed with intradermal transversal suture. Results: From January 2009 to August 2015, seven patients diagnosed with vaginal agenesis underwent this technique. There were no major complications or need for blood transfusions. At the six-month follow-up, all patients reported satisfactory sexual intercourse. There were no significant complications at donor site or neovagina that needed surgical intervention. Conclusion: Vaginal reconstruction using the perforated graft is viable with excellent functional results. Applying this modification, we yielded the good results of a classic McIndoe technique with lower donor site morbidity.

  12. The Impact of Recipient Site External Expansion in Fat Grafting Surgical Outcomes

    Directory of Open Access Journals (Sweden)

    Carlo M. Oranges, MD

    2018-02-01

    Conclusions:. External expansion and fat grafting is a promising technique for breast reconstruction and augmentation. However, due to the overall low level of evidence of the available studies, further research is needed to validate the procedure.

  13. Budget impact analysis of heparin-bonded polytetrafluoroethylene grafts (Propaten) against standard polytetrafluoroethylene grafts for below-the-knee bypass in patients with critical limb ischaemia in France

    Science.gov (United States)

    Vergnaud, Simon; Riche, Valéry-Pierre; Tessier, Philippe; Mauduit, Nicolas; Kaladji, Adrien; Gouëffic, Yann

    2018-01-01

    Objectives To evaluate the budget impact of progressive replacement of standard polytetrafluoroethylene (PTFE) grafts by heparin-bound PTFE (Propaten) for below-the-knee (BTK) bypass in patients with critical limb ischaemia (CLI). Design From a review of the scientific literature, we calculated a theoretical BTK primary patency for Propaten grafts. Using the French hospital expenditure database (PMSI), we retrospectively estimated a rehospitalisation rate for standard PTFE grafts. From these data, a model was created to assess the budget impact of a progressive replacement from standard PTFE grafts to Propaten grafts over a 5-year horizon. We performed an univariate sensitivity analysis to assess the robustness of our results. Setting French National Health Insurance (FNHI) perspective. Participant Patients with CLI. Main outcome measures Budget impact analysis. Results Data extraction from the PMSI revealed that 656 patients were treated with PTFE grafts in 2011 in French public hospitals for a BTK bypass. Assuming a 2-year survival rate of 76.8%, observed reinterventions rate for standard PTFE grafts at 24 months from the PMSI was 35.1%. The mean rehospitalisation cost was €10 689. The budget impact analysis based on these data found a net cumulative 5-year payer budget reduction of €112 420 in favour of Propaten, under the assumption of a 75.6% primary patency for Propaten grafts for a projected population of 3215 patients of which 801 received a Propaten graft. Conclusions Our budget impact analysis showed a positive impact on the national health insurance budget of the replacement of standard PTFE grafts by Propaten grafts for BTK bypass in patients with CLI in France. This supports the enactment of a reimbursement policy by the FNHI. PMID:29490953

  14. Original technique for penile girth augmentation through porcine dermal acellular grafts: results in a 69-patient series.

    Science.gov (United States)

    Alei, Giovanni; Letizia, Piero; Ricottilli, Francesco; Simone, Pierfranco; Alei, Lavinia; Massoni, Francesco; Ricci, Serafino

    2012-07-01

    Although different techniques for augmentation phalloplasty have been reported in the medical literature, this issue is still highly controversial, and none of the proposed procedures has been unanimously approved. The aim of this study is to describe an innovative surgical technique for penile girth augmentation with porcine dermal acellular grafts, through a small transverse incision at the penile base, along the penopubic junction. Between 2000 and 2009, 104 patients were referred to our institution for penile enhancement. After a preoperative psychosexual consultation and a general medical assessment, 69 patients were deemed suitable good candidates for surgery. The average penis circumference was measured at the mid-length of the penis and was 8.1 cm (5.4-10.7 cm) and 10.8 cm (6.5-15.8 cm) during flaccidity and erection, respectively. All patients received penile augmentation with porcine dermal acellular grafts. Results evaluation of an innovative technique for penile girth augmentation through exogenous porcine grafts and small penobubic incision. Postoperative measurements were performed at 6 and 12 months. At the 1-year follow-up, the average penis circumference was 11.3 cm (8.2-13.2 cm, 3.1 cm mean increase) during flaccidity and 13.2 cm (8.8-14.5 cm, 2.4 cm mean increase) during erection. No major complications occurred in the series. Minor complications were resolved with conservative treatment within 3 weeks. Sexual activity was resumed from 1 to 2 months after surgery. The psychosexual impact of the operation was beneficial in the majority of cases. Penile girth enlargement with acellular dermal matrix grafts has several advantages over augmentation with autogenous dermis-fat grafts: the elimination of donor site morbidity and a significantly shorter operation time. With this approach, through a short dorsal incision at the base of the penis, the scar is concealed in a crease covered by pubic hair and thus hardly visible. © 2012

  15. Arthroscopic Latarjet Techniques: Graft and Fixation Positioning Assessed With 2-Dimensional Computed Tomography Is Not Equivalent With Standard Open Technique.

    Science.gov (United States)

    Neyton, Lionel; Barth, Johannes; Nourissat, Geoffroy; Métais, Pierre; Boileau, Pascal; Walch, Gilles; Lafosse, Laurent

    2018-05-19

    To analyze graft and fixation (screw and EndoButton) positioning after the arthroscopic Latarjet technique with 2-dimensional computed tomography (CT) and to compare it with the open technique. We performed a retrospective multicenter study (March 2013 to June 2014). The inclusion criteria included patients with recurrent anterior instability treated with the Latarjet procedure. The exclusion criterion was the absence of a postoperative CT scan. The positions of the hardware, the positions of the grafts in the axial and sagittal planes, and the dispersion of values (variability) were compared. The study included 208 patients (79 treated with open technique, 87 treated with arthroscopic Latarjet technique with screw fixation [arthro-screw], and 42 treated with arthroscopic Latarjet technique with EndoButton fixation [arthro-EndoButton]). The angulation of the screws was different in the open group versus the arthro-screw group (superior, 10.3° ± 0.7° vs 16.9° ± 1.0° [P open inferior screws (P = .003). In the axial plane (level of equator), the arthroscopic techniques resulted in lateral positions (arthro-screw, 1.5 ± 0.3 mm lateral [P open technique (0.9 ± 0.2 mm medial). At the level of 25% of the glenoid height, the arthroscopic techniques resulted in lateral positions (arthro-screw, 0.3 ± 0.3 mm lateral [P open technique (1.0 ± 0.2 mm medial). Higher variability was observed in the arthro-screw group. In the sagittal plane, the arthro-screw technique resulted in higher positions (55% ± 3% of graft below equator) and the arthro-EndoButton technique resulted in lower positions (82% ± 3%, P open technique (71% ± 2%). Variability was not different. This study shows that the position of the fixation devices and position of the bone graft with the arthroscopic techniques are statistically significantly different from those with the open technique with 2-dimensional CT assessment. In the sagittal plane, the arthro-screw technique provides the highest

  16. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  17. The Impact of Liver Graft Injury on Cancer Recurrence Posttransplantation.

    Science.gov (United States)

    Li, Chang-Xian; Man, Kwan; Lo, Chung-Mau

    2017-11-01

    Liver transplantation is the most effective treatment for selected patients with hepatocellular carcinoma. However, cancer recurrence, posttransplantation, remains to be the critical issue that affects the long-term outcome of hepatocellular carcinoma recipients. In addition to tumor biology itself, increasing evidence demonstrates that acute-phase liver graft injury is a result of hepatic ischemia reperfusion injury (which is an inevitable consequence during liver transplantation) and may promote cancer recurrence at late phase posttransplantation. The liver grafts from living donors, donors after cardiac death, and steatotic donors have been considered as promising sources of organs for liver transplantation and are associated with high incidence of liver graft injury. The acute-phase liver graft injury will trigger a series of inflammatory cascades, which may not only activate the cell signaling pathways regulating the tumor cell invasion and migration but also mobilize the circulating progenitor and immune cells to facilitate tumor recurrence and metastasis. The injured liver graft may also provide the favorable microenvironment for tumor cell growth, migration, and invasion through the disturbance of microcirculatory barrier function, induction of hypoxia and angiogenesis. This review aims to summarize the latest findings about the role and mechanisms of liver graft injury resulted from hepatic ischemia reperfusion injury on tumor recurrence posttransplantation, both in clinical and animal cohorts.

  18. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique.

    Science.gov (United States)

    Sharma, Umesh; Yadav, Sher Singh; Tomar, Vinay; Garg, Amit

    2016-01-01

    This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG) in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm) was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up) and subsequent follow up. Mean stricture length was 4.66 cm (range, 3-8.5 cm) and mean operative time was 195 min. (range, 160 to 200 min.). The technique was successful (normal voiding with no need for any post-operative procedure) in 11(91.6%) patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  19. [Bone graft reconstruction for posterior mandibular segment using the formwork technique].

    Science.gov (United States)

    Pascual, D; Roig, R; Chossegros, C

    2014-04-01

    Pre-implant bone graft in posterior mandibular segments is difficult because of masticatory and lingual mechanical constraints, because of the limited bone vascularization, and because of the difficulty to cover it with the mucosa. The formwork technique is especially well adapted to this topography. The recipient site is abraded with a drill. Grooves are created to receive and stabilize the grafts. The bone grafts were harvested from the ramus. The thinned cortices are assembled in a formwork and synthesized by mini-plates. The gaps are filled by bone powder collected during bone harvesting. The bone volume reconstructed with the formwork technique allows anchoring implants more than 8mm long. The proximity of the inferior alveolar nerve does not contra indicate this technique. The formwork size and its positioning on the alveolar crest can be adapted to prosthetic requirements by using osteosynthesis plates. The lateral implant walls are supported by the formwork cortices; the implant apex is anchored on the native alveolar crest. The primary stability of implants is high, and the torque is important. The ramus harvesting decreases operative risks. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. Outcome after the modified Bentall technique with a long interposed graft to the left coronary artery.

    Science.gov (United States)

    Nakahira, Atsushi; Shibata, Toshihiko; Sasaki, Yasuyuki; Hirai, Hidekazu; Hattori, Koji; Hosono, Mitsuharu; Ehara, Shoichi; Suehiro, Shigefumi

    2009-01-01

    The modified Bentall technique, which was reported by Svensson in 1992, is an aortic root composite valve graft replacement involving reimplantation of the left coronary ostium with a long interposed graft wrapping behind the composite graft. The technique is technically advantageous, particularly for complicated or redo aortic roots. To justify the technique, the midterm outcome needs to be evaluated. Since 1992, 40 patients (4 with Marfan syndrome) underwent the modified Bentall technique (Svensson's modification). The mean age was 54.7 +/- 13.6 years, and 32 patients (80.0%) were male. All hospital survivors have been consecutively followed with annual echocardiographic evaluations. Furthermore, in 2007, multislice computed tomography was performed at 4.7 +/- 3.5 years (maximum, 14.9 years) postoperatively in 30 patients who had preserved renal function. No patients have experienced any complications regarding the technique at the follow-up of 5.7 +/- 4.0 years (maximum, 14.9 years), although there were 2 hospital deaths of emergency cases and 5 late deaths owing to noncardiac causes. In 35 patients (92.1% of hospital survivors), no structural complications were detected by multislice computed tomographies of the 30 patients or coronary angiograms of the remaining 5 patients. The consecutive echocardiographic follow-ups showed well-preserved left ventricular function with the most recent ejection fraction being 0.581 +/- 0.078. This Svensson's modification technique was associated with favorable midterm outcomes by multislice computed tomography and consecutive echocardiographic evaluations, indicating long-lasting advantages as well as technical benefits. Thus, the technique can be considered as a helpful and justifiable alternative method.

  1. Knee stabiligy after ACL reconstruction through graft fixation in femoral tunnel: transfemoral pinning versus endobutton techniques

    Directory of Open Access Journals (Sweden)

    Tahmasebi MN

    2011-05-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: One of the most common orthopedic complaints is direct or indirect trauma to the knee with torn anterior cruciate ligament (ACL. Reconstruction of the torn ACL is emphatically offered in active individuals as by this operation, we prevent osteoarthritis, knee instability and injury to the meniscus. There are numerous methods for graft fixation in the femoral tunnel in ACL reconstruction. If the graft proves to be stable after the operation, patients would not complain of giving way knee joints. In this clinical trial, we compared transfemoral pinning with endobutton fixation of hamstring graft in arthroscopic ACL reconstruction by examining knee stability and use of other relevant functional tests. "n"nMethods : Fourteen Patients who had undergone arthroscopic ACL reconstruction in Shariati Hospital during the years 2008-2009 and were being followed up were evaluated at least 15 months post-operatively by physical examination and the use of an arthrometer made by the Faculty of Mechanics of Sharif Technical University."n"nResults : The results showed that two out of seven patients in which their ACL had been reconstructed by hamstring graft fixation by endobutton technique, and

  2. Osteotome-Mediated Sinus Lift without Grafting Material: A Review of Literature and a Technique Proposal

    Science.gov (United States)

    Taschieri, Silvio; Corbella, Stefano; Saita, Massimo; Tsesis, Igor; Del Fabbro, Massimo

    2012-01-01

    Implant rehabilitation of the edentulous posterior maxilla may be a challenging procedure in the presence of insufficient bone volume for implant placement. Maxillary sinus augmentation with or without using grafting materials aims to provide adequate bone volume. The aim of the present study was to systematically review the existing literature on transalveolar maxillary sinus augmentation without grafting materials and to propose and describe an osteotome-mediated approach in postextraction sites in combination with platelet derivative. The systematic review showed that high implant survival rate (more than 96% after 5 years) can be achieved even without grafting the site, with a low rate of complications. Available alveolar bone height before surgery was not correlated to survival rate. In the described case report, three implants were placed in posterior maxilla after extraction of two teeth. An osteotome-mediated sinus lifting technique was performed with the use of platelet derivative (PRGF); a synthetic bone substitute was used to fill the gaps between implant and socket walls. No complications occurred, and implants were successfully in site after 1 year from prosthetic loading. The presented technique might represent a viable alternative for the treatment of edentulous posterior maxilla with atrophy of the alveolar bone though it needs to be validated by studies with a large sample size. PMID:22792108

  3. Osteotome-Mediated Sinus Lift without Grafting Material: A Review of Literature and a Technique Proposal

    Directory of Open Access Journals (Sweden)

    Silvio Taschieri

    2012-01-01

    Full Text Available Implant rehabilitation of the edentulous posterior maxilla may be a challenging procedure in the presence of insufficient bone volume for implant placement. Maxillary sinus augmentation with or without using grafting materials aims to provide adequate bone volume. The aim of the present study was to systematically review the existing literature on transalveolar maxillary sinus augmentation without grafting materials and to propose and describe an osteotome-mediated approach in postextraction sites in combination with platelet derivative. The systematic review showed that high implant survival rate (more than 96% after 5 years can be achieved even without grafting the site, with a low rate of complications. Available alveolar bone height before surgery was not correlated to survival rate. In the described case report, three implants were placed in posterior maxilla after extraction of two teeth. An osteotome-mediated sinus lifting technique was performed with the use of platelet derivative (PRGF; a synthetic bone substitute was used to fill the gaps between implant and socket walls. No complications occurred, and implants were successfully in site after 1 year from prosthetic loading. The presented technique might represent a viable alternative for the treatment of edentulous posterior maxilla with atrophy of the alveolar bone though it needs to be validated by studies with a large sample size.

  4. Study by the positron annihilation technique of Graft copolimerization of methyl methacrylate in polyethylene induced by gamma radiation

    International Nuclear Information System (INIS)

    Zaldivar Gonzalez, M.E.

    1992-01-01

    Radiation initiated grafting is a very broad field which has attracted considerable interest over the last two decades. Graft copolymers may combine suitable properties of two polymeric components. Radiation methods are particulary appropiate for the production of a large variety of graft copolymers having interesting properties. Ionizing radiation has provided a convenient and clean method to activate a sustrate polymer and undoubtedly, it has added impetus to this field of research. In the present work, graft polymerization of methyl methacrylate (MMA) onto low density polyethylene (LDPE) was carried out. The effect of gamma ray irradiation dose on the grafting degree was investigated for two different methods: direct and preirradiation. The best method to prepare the copolymer for the LDPE film thickness studied: 0.05 and 0.2 mm., was direct method. In both polyethylene thickness, the grafting degree increased as a function of the reaction time. However, grafting for LDPE 0.2 mm. it is better, because the copolymer with that thickness conserve the main physical-chemistry properties of the LDPE along the different grafting degrees obtained, which it is important for practical purposes. Infrared spectroscopy was used to probe the changes ocurred in the LDPE structure with the graft of MMA, first spectrum showed typical bands for LDPE structure, while in the second spectrum new bands appeared which corresponded to PMMA structure grafted onto LDPE. Positron annihilation lifetime technique was applied to study the copolymer microstructure according to increase of grafting degree. O-PS lifetime and intensity tend to decrease. This behavior could be due to the diminution of free volume in the original LDPE matrix as grafting proceeds. Copolymer morphology was observed using optical microscopy (Author)

  5. Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope™

    Directory of Open Access Journals (Sweden)

    Takahisa Sasho

    2018-04-01

    Full Text Available In most anterior cruciate ligament (ACL reconstructions, grafts are fixed to the femoral side first followed by the tibial side. Various techniques have been reported to achieve optimal tension on the grafts, but once the grafts are fixed it is difficult to adjust graft tension further. To enable post fixation tension control we have invented a new graft configuration using an adjustable loop-device (TightRopeTM, Arthrex, FL, USA on the tibial side. In this paper, biomechanical properties of this configuration using soft tissue were examined in terms of graft diameter and various suture techniques (referred to as base suture to make a closed circle to support TightRopeTM.Two experiments were conducted under different conditions. In each experiment, cyclic load, followed by a pull-to-failure load, was applied to the grafts and elongation and failure mode were recorded. (1 To evaluate the effects of diameter, 5.0 or 6.0 mm grafts were prepared by a single locking loop stitch as the base suture (SLL5, SLL6. (2 To evaluate different base sutures, 5.0 mm tendons were used, and grafts were prepared using five kinds of base sutures (SLL, ZLL: zigzag locking loop, DZLL: double zigzag locking loop, DK: double Krackow, DK w/o TR: double Krackow without TightRopeTM. In the first experiment, tearing was observed in 2 of 6 cases in the SLL5 test group, whereas no tearing was observed with SLL6. In the second experiment, no tearing was observed with DZLL or DK. Elongation was smaller in these two groups compared to the other groups. Mechanical strength decreases with a smaller graft diameter. Biomechanical properties differed with different base sutures and, among them, the double-zigzag-suture stitch and double Krackow provided less elongation and higher ultimate load in this graft configuration.

  6. Keratinocyte-Melanocyte graft technique followed by PUVA therapy for stable vitiligo

    Directory of Open Access Journals (Sweden)

    Kachhawa Dilip

    2008-01-01

    Full Text Available Background: Various surgical procedures for correcting stable vitiligo exist but these have their own limitations. Autologous, non-cultured, non-trypsinized, melanocyte plus keratinocyte grafting is a new and simple method of vitiligo surgery. Objective: The study aimed to evaluate efficacy of a new grafting technique in vitiligo patches. Methods: Eighteen vitiligo patches underwent this procedure. The upper layer of epidermis was removed by superficial dermabrasion using a dermabrader micromotor until the epidermis appeared wet and shiny. Then, antibiotic ointment was applied and dermabrasion was continued up to the whitish area of the upper dermis. The paste-like material (ointment with entangled epidermal particles was collected and spread over the dermabraded recipient site. Results: Pigmentation usually started at 4-6 weeks. Complete uniform pigmentation took 16-20 weeks. Conclusion: For smaller vitiligo patches this method gives cosmetically acceptable results. It is easy to perform and does not require specific laboratory setup.

  7. RECONSTRUCTION OF ATROPHIC MAXILLA BY ANTERIOR ILIAC CREST BONE GRAFTING VIA NEUROAXIAL BLOCKADE TECHNIQUE: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Erol CANSIZ

    2017-01-01

    Full Text Available Anterior iliac crest bone grafting is a well-established modality in the treatment of alveolar bone deficiencies. However, this procedure may also have considerable postoperative morbidity which is mostly related to general anesthesia. Postoperative pain-related complications can be managed by neuroaxial blockade techniques which provide adequate surgical analgesia and reduce postoperative pain. This clinical report describes the reconstruction of a severely atrophic maxilla with anterior iliac crest bone grafting using combined spinal epidural anesthesia. Neuroaxial blockade techniques may be a useful alternative to eliminate general anesthesia related challenges of anterior iliac crest bone grafting procedures.

  8. Impact of real-time metabolomics in liver transplantation: Graft evaluation and donor-recipient matching.

    Science.gov (United States)

    Faitot, Francois; Besch, Camille; Battini, Stephanie; Ruhland, Elisa; Onea, Mihaela; Addeo, Pietro; Woehl-Jaeglé, Marie-Lorraine; Ellero, Bernard; Bachellier, Philippe; Namer, Izzie-Jacques

    2017-12-02

    There is an emerging need to assess the metabolic state of liver allografts especially in the novel setting of machine perfusion preservation and donor in cardiac death (DCD) grafts. High-resolution magic-angle-spinning nuclear magnetic resonance (HR-MAS-NMR) could be a useful tool in this setting as it can extemporaneously provide untargeted metabolic profiling. The purpose of this study was to evaluate the potential value of HR-MAS-NMR metabolomic analysis of back-table biopsies for the prediction of early allograft dysfunction (EAD) and donor-recipient matching. The metabolic profiles of back-table biopsies obtained by HR-MAS-NMR, were compared according to the presence of EAD using partial least squares discriminant analysis. Network analysis was used to identify metabolites which changed significantly. The profiles were compared to native livers to identify metabolites for donor-recipient matching. The metabolic profiles were significantly different in grafts that caused EAD compared to those that did not. The constructed model can be used to predict the graft outcome with excellent accuracy. The metabolites showing the most significant differences were lactate level >8.3 mmol/g and phosphocholine content >0.646 mmol/g, which were significantly associated with graft dysfunction with an excellent accuracy (AUROC lactates  = 0.906; AUROC phosphocholine  = 0.816). Native livers from patients with sarcopenia had low lactate and glycerophosphocholine content. In patients with sarcopenia, the risk of EAD was significantly higher when transplanting a graft with a high-risk graft metabolic score. This study underlines the cost of metabolic adaptation, identifying lactate and choline-derived metabolites as predictors of poor graft function in both native livers and liver grafts. HR-MAS-NMR seems a valid technique to evaluate graft quality and the consequences of cold ischemia on the graft. It could be used to assess the efficiency of graft resuscitation on

  9. Novel Technique for Rebubbling DMEK Grafts at the Slit Lamp Using Intravenous Extension Tubing.

    Science.gov (United States)

    Sáles, Christopher S; Straiko, Michael D; Terry, Mark A

    2016-04-01

    To describe a novel technique for rebubbling DMEK grafts at the slit lamp using a cannula coupled to a syringe with intravenous (IV) extension tubing. We present a retrospective case series of eyes that underwent rebubbling using a novel technique at the slit lamp. The rebubbling apparatus is assembled using a standard 43-inch IV extension tube, a 5-cc luer lock syringe, and a 27-gauge cannula. The cannula is screwed onto one end of the extension tubing, and a 5-cc syringe that has been filled with air is screwed onto the opposite end. With the patient seated at the slit lamp, the cannula is positioned in the anterior chamber by the surgeon with one hand while the other hand operates the syringe and the joystick. We performed 5 rebubbling procedures at the slit lamp using a standard syringe and cannula. Despite suboptimal ergonomics with this approach, all of these cases achieved sufficient air fills without any complications. Four rebubbling procedures were subsequently performed at the slit lamp using our novel rebubbling technique. All of these cases also attained sufficient air fills without complications, but they were noted to be much easier to perform by the surgeon. Using IV extension tubing to couple a syringe to a cannula for rebubbling DMEK grafts at the slit lamp is ergonomically superior to the conventional alternative of using a standard cannula on a syringe. The technique is also simple and inexpensive to adopt.

  10. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique

    Directory of Open Access Journals (Sweden)

    Umesh Sharma

    2016-01-01

    Full Text Available Aims: This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. Materials and Methods: The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. Results: A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up and subsequent follow up. Mean stricture length was 4.66 cm (range, 3–8.5 cm and mean operative time was 195 min. (range, 160 to 200 min.. The technique was successful (normal voiding with no need for any post-operative procedure in 11(91.6% patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Conclusion: Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  11. Simplified technique for auxiliary orthotopic liver transplantation using a whole graft

    Science.gov (United States)

    ROCHA-SANTOS, Vinicius; NACIF, Lucas Souto; PINHEIRO, Rafael Soares; DUCATTI, Liliana; ANDRAUS, Wellington; D'ALBURQUERQUE, Luiz Carneiro

    2015-01-01

    Background Acute liver failure is associated with a high mortality rate and the main purposes of treatment are to prevent cerebral edema and infections, which often are responsible for patient death. The orthotopic liver transplantation is the gold standard treatment and improves the 1-year survival. Aim To describe an alternative technique to auxiliary liver transplant on acute liver failure. Method Was performed whole auxiliary liver transplantation as an alternative technique for a partial auxiliary liver transplantation using a whole liver graft from a child removing the native right liver performed a right hepatectomy. The patient met the O´Grady´s criteria and the rational to indicate an auxiliary orthotopic liver transplantation was the acute classification without hemodynamic instability or renal failure in a patient with deterioration in consciousness. Results The procedure improved liver function and decreased intracranial hypertension in the postoperative period. Conclusion This technique can overcome some postoperative complications that are associated with partial grafts. As far as is known, this is the first case of auxiliary orthotopic liver transplantation in Brazil. PMID:26176253

  12. Treatment of Rockwood type III acromioclavicular joint dislocation using autogenous semitendinosus tendon graft and endobutton technique

    Directory of Open Access Journals (Sweden)

    Ye G

    2016-01-01

    Full Text Available Gang Ye, Chao-An Peng, Hua-Bin Sun, Jing Xiao, Kang Zhu Department of Orthopedics, the People’s Hospital of Huangpi District, Wuhan City, People’s Republic of China Background: The aim of this study was to evaluate the therapeutic effect of autogenous semitendinosus graft and endobutton technique, and compare with hook plate in treatment of Rockwood type III acromioclavicular (AC joint dislocation.Methods: From April 2012 to April 2013, we treated 46 patients with Rockwood type III AC joint dislocation. Patients were randomly divided into two groups: Group A was treated using a hook plate and Group B with autogenous semitendinosus graft and endobutton technique. All participants were followed up for 12 months. Radiographic examinations were performed every 2 months postoperatively, and clinical evaluation was performed using the Constant–Murley score at the last follow-up.Results: Results indicated that patients in Group B showed higher mean scores (90.3±5.4 than Group A (80.4±11.5 in terms of Constant–Murley score (P=0.001. Group B patients scored higher in terms of pain (P=0.002, activities (P=0.02, range of motion (P<0.001, and strength (P=0.004. In Group A, moderate pain was reported by 2 (8.7% and mild pain by 8 (34.8% patients. Mild pain was reported by 1 (4.3% patient in Group B. All patients in Group B maintained complete reduction, while 2 (8.7% patients in Group A experienced partial reduction loss. Two patients (8.7% encountered acromial osteolysis on latest radiographs, with moderate shoulder pain and limited range of motion.Conclusion: Autogenous semitendinosus graft and endobutton technique showed better results compared with the hook plate method and exhibited advantages of fewer complications such as permanent pain and acromial osteolysis. Keywords: Rockwood type III acromioclavicular joint dislocation, autogenous semitendinosus graft, endobutton, hook plate

  13. GORE PRECLUDE MVP dura substitute applied as a nonwatertight "underlay" graft for craniotomies: product and technique evaluation.

    Science.gov (United States)

    Chappell, E Thomas; Pare, Laura; Salehpour, Mohammed; Mathews, Marlon; Middlehof, Charles

    2009-01-01

    While watertight closure of the dura is a long-standing tenet of cranial surgery, it is often not possible and sometimes unnecessary. Many graft materials with various attributes and drawbacks have been in use for many years. A novel synthetic dural graft material called GORE PRECLUDE MVP dura substitute (WL Gore & Associates, Inc, Flagstaff, Ariz) (henceforth called "MVP") is designed for use both in traditional watertight dural closure and as a dural "underlay" graft in a nonwatertight fashion. One surface of MVP is engineered to facilitate fibroblast in-growth so that its proximity to the underside of the dura will lead to rapid incorporation, whereas the other surface acts as a barrier to reduce tissue adhesion to the device. A series of 59 human subjects undergoing craniotomy and available for clinical and radiographic follow-up underwent nonwatertight underlay grafting of their durotomy with MVP. This is an assessment of the specific product and technique. No attempt is made to compare this to other products or techniques. The mean follow-up in this group was more than 4 months. All subjects have ultimately experienced excellent outcomes related to use of the graft implanted with the underlay technique. No complications occurred related directly to MVP, but the wound-related complication rate attributed to the underlay technique was higher than expected (17%). However, careful analysis found a high rate of risk factors for wound complications and determined that complications with the underlay technique could be avoided by assuring close approximation of the graft material to the underside of the dura. MVP can be used as an underlay graft in a nonwatertight fashion. However, if used over large voids (relaxed brain or large tumor bed), "tacking" or traditional watertight closure techniques should be used. The underlay application of MVP is best applied over the convexities and is particularly well-suited to duraplasty after hemicraniectomy.

  14. Alveolar ridge augmentation by connective tissue grafting using a pouch method and modified connective tissue technique: A prospective study.

    Science.gov (United States)

    Agarwal, Ashish; Gupta, Narinder Dev

    2015-01-01

    Localized alveolar ridge defect may create physiological and pathological problems. Developments in surgical techniques have made it simpler to change the configuration of a ridge to create a more aesthetic and more easily cleansable shape. The purpose of this study was to compare the efficacy of alveolar ridge augmentation using a subepithelial connective tissue graft in pouch and modified connective tissue graft technique. In this randomized, double blind, parallel and prospective study, 40 non-smoker individuals with 40 class III alveolar ridge defects in maxillary anterior were randomly divided in two groups. Group I received modified connective tissue graft, while group II were treated with subepithelial connective tissue graft in pouch technique. The defect size was measured in its horizontal and vertical dimension by utilizing a periodontal probe in a stone cast at base line, after 3 months, and 6 months post surgically. Analysis of variance and Bonferroni post-hoc test were used for statistical analysis. A two-tailed P connective tissue graft proposed significantly more improvement as compare to connective tissue graft in pouch.

  15. Electrolytic membrane formation of fluoroalkyl polymer using a UV-radiation-based grafting technique and sulfonation

    Energy Technology Data Exchange (ETDEWEB)

    Shironita, Sayoko; Mizoguchi, Satoko; Umeda, Minoru, E-mail: mumeda@vos.nagaokaut.ac.jp [Department of Materials Science and Technology, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka 940-2188, Niigata (Japan)

    2011-03-15

    A sulfonated fluoroalkyl graft polymer (FGP) membrane was prepared as a polymer electrolyte. First, the FGP membrane was grafted with styrene under UV irradiation. The grafted FGP was then sulfonated to functionalize it for proton conductivity. The grafting degree of the membrane increased with increasing grafting time during UV irradiation. The proton conductivity of the membrane increased with increasing grafting degree. The swelling ratio was independent of the grafting time, however, the water uptake increased with increasing grafting degree. Based on these results, it was found that the UV-initiated styrene grafting occurred along the membrane thickness direction. Moreover, the membrane was embedded within the glass fibers of the composite. This composite electrolytic membrane had 1.15 times the proton conductivity of a Nafion 117 membrane.

  16. Hamstrings tendon graft preparation for anterior cruciate ligament reconstruction using the WhipKnotTM soft tissue cinch technique.

    Directory of Open Access Journals (Sweden)

    Amin Masoumiganjgah

    2012-04-01

    Full Text Available BackgroundAppropriate graft tension and secure graft incorporation inbone tunnels are essential for successful anterior cruciateligament (ACL reconstruction using hamstrings tendonautografts. The WhipKnot™ soft tissue cinch, introduced bySmith and Nephew in 2004, is an alternative option to thecommonly used whipstitch technique during preparation ofthe hamstring autograft in ACL reconstruction.AimsTo investigate the effectiveness of the WhipKnot™ softtissue cinch and technique during the preparation of thetendon graft for ACL reconstruction.MethodA total of 33 ACL reconstruction operations performedbetween February 2011 and December 2011 were includedin this study. These were performed by a single seniorsurgeon who used the Whipknot™ technique for thepreparation of each graft. Four were used for eachoperation; two for each end of the harvested hamstringstendons, including semitendinosus and gracilis tendonsrespectively.ResultsIn total, 132 WhipKnots were used during the kneeoperations. Use of the WhipKnot™ technique resulted insuccessful graft preparations, tensioning and effective graftplacement in the tibial and femoral tunnels in almost allinstances. Only one case of WhipKnot™ failure (slippagewas recorded.ConclusionThese results indicate that the Whipknot™ technique is asafe, reliable and practical option for the preparation of thehamstrings autografts.

  17. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  18. Mandible vertical height correction using lingual bone-split pedicle onlay graft technique

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-09-01

    Full Text Available As edentulous mandible become atrophic, a denture bearing area will also be reduced. Difficulty in the removable prosthesis rehabilitation will be present as well. The purpose of this paper reports an innovative surgical technique to cope a problem of unstable complete lower denture due to bone atrophy and resulted of vertical height reduction of the anterior region of the mandible necessary for denture retention. Vertical advancement of the lower jaw using lingual bone split pedicle onlay graft technique in the anterior region of the mandible and followed by secondary epithelization vestibuloplasty in achieving the vertical height dimension. The surgery was achieved satisfactorily as the vertical dimension of the mandible anterior region had increased and the denture seated more stable comparing with the previous denture worn by the patient. It concluded that the surgery was achieved with a great result as the vertical height of the anterior region of the mandible had increased positively therefore lead the denture seated more stable.

  19. Dorsal buccal mucosal graft urethroplasty for anterior urethral stricture by Asopa technique.

    Science.gov (United States)

    Pisapati, V L N Murthy; Paturi, Srimannarayana; Bethu, Suresh; Jada, Srikanth; Chilumu, Ramreddy; Devraj, Rahul; Reddy, Bhargava; Sriramoju, Vidyasagar

    2009-07-01

    Buccal mucosal graft (BMG) substitution urethroplasty has become popular in the management of intractable anterior urethral strictures with good results. Excellent long-term results have been reported by both dorsal and ventral onlay techniques. Asopa reported a successful technique for dorsal placement of BMG in long anterior urethral strictures through a ventral sagittal approach. To evaluate prospectively the results and advantages of dorsal BMG urethroplasty for recurrent anterior urethral strictures by a ventral sagittal urethrotomy approach (Asopa technique). From December 2002 to December 2007, a total of 58 men underwent dorsal BMG urethroplasty by a ventral sagittal urethrotomy approach for recurrent urethral strictures. Forty-five of these patients with a follow-up period of 12-60 mo were prospectively evaluated, and the results were analysed. The urethra was split twice at the site of the stricture both ventrally and dorsally without mobilising it from its bed, and the buccal mucosal graft was secured in the dorsal urethral defect. The urethra was then retubularised in one stage. The overall results were good (87%), with a mean follow-up period of 42 mo. Seven patients developed minor wound infection, and five patients developed fistulae. There were six recurrences (6:45, 13%) during the follow-up period of 12-60 mo. Two patients with a panurethral stricture and four with bulbar or penobulbar strictures developed recurrences and were managed by optical urethrotomy and self-dilatation. The medium-term results were as good as those reported with the dorsal urethrotomy approach. Long-term results from this and other series are awaited. More randomised trials and meta-analyses are needed to establish this technique as a procedure of choice in future. The ventral sagittal urethrotomy approach is easier to perform than the dorsal urethrotomy approach, has good results, and is especially useful in long anterior urethral strictures.

  20. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    Science.gov (United States)

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  1. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  2. Use of modified Sandwich-graft technique to preserve hypogastric artery in EVAR treatment of complex aortic aneurysm anatomy.

    Science.gov (United States)

    Mosquera Arochena, N; Rodríguez Feijoo, G; Carballo Fernandez, C; Molina Herrero, F; Fernandez Lebrato, R; Barrios Castro, A; Garcia Fernandez, I

    2011-10-01

    Since the introduction of the first endoprosthetic devices, continuous development in techniques and implants has occurred, such as the introduction of a stent graft with branches designed to preserve antegrade flow in the hypogastric artery, a stent-graft designed to treat extreme neck angulation and iliac tortuosity, as well as "Sandwich" and "Chimney" techniques used to maintain perfusion in branch vessels originating in the region to be treated. This paper describes how the Sandwich-Graft technique was adapted, as described by Lobato et al., employing the Aorfix™ system (Lombard Medical) and the Viabahn™ (W.L.Gore) to preserve hypogastric flow in cases with extreme neck angulation and iliac tortuosity. The study included four patients treated from April 2010 until November 2010 with the modified Sandwich technique. All patients eligible for this approach were considered unfit for open repair and were not suitable for an iliac branch graft (Z-BIS Zenith™ Cook Medical). A bifurcated endograft was implanted with specific, in-situ, branching to the target hypogastric artery and achieved clinical and technical success, in all the patients. After a 11-month follow-up in two cases and a six-month follow-up in the other two, clinical results were successful. All patients were endoleak-free, had patent hypogastric branches and had shrinking or stable aneurysms. The initial experience shows that the Sandwich technique with the Aorfix™ stent-graft demonstrated to be effective in endovascular repair of abdominal aortic aneurysms in patients with aortoiliac anatomy hostile to preserving hypogastric artery patency. This graft allows a broader group of patients to be treated with endovascular repair without potential complications of hypogastric artery occlusion; however, further studies are needed to evaluate long-term results in larger numbers of patients.

  3. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  4. Application of radiation grafting techniques to prepare the high molecular weight water-soluble polymer

    International Nuclear Information System (INIS)

    Le Hai; Nguyen Quoc Hien; Nguyen Tan Man; Truong Thi Hanh; Le Huu Tu; Tran Thi Tam; Pham Thi Sam; Pham Anh Tuan; Le Dinh Lang

    2003-01-01

    The results of the study on the preparation of the high molecular weight water-soluble polymers by radiation grafting and their properties is presented as follows: 1/ by radiation grafting, the molecular weight of PVA was increased 20 times and PAM was increased only 3 times; 2/ the thermal and medium stability of poly(vinyl alcohol) grafted with acrylamide was obviously improved. (LH)

  5. Alveolar ridge augmentation by connective tissue grafting using a pouch method and modified connective tissue technique: A prospective study

    Directory of Open Access Journals (Sweden)

    Ashish Agarwal

    2015-01-01

    Full Text Available Background: Localized alveolar ridge defect may create physiological and pathological problems. Developments in surgical techniques have made it simpler to change the configuration of a ridge to create a more aesthetic and more easily cleansable shape. The purpose of this study was to compare the efficacy of alveolar ridge augmentation using a subepithelial connective tissue graft in pouch and modified connective tissue graft technique. Materials and Methods: In this randomized, double blind, parallel and prospective study, 40 non-smoker individuals with 40 class III alveolar ridge defects in maxillary anterior were randomly divided in two groups. Group I received modified connective tissue graft, while group II were treated with subepithelial connective tissue graft in pouch technique. The defect size was measured in its horizontal and vertical dimension by utilizing a periodontal probe in a stone cast at base line, after 3 months, and 6 months post surgically. Analysis of variance and Bonferroni post-hoc test were used for statistical analysis. A two-tailed P < 0.05 was considered to be statistically significant. Results: Mean values in horizontal width after 6 months were 4.70 ± 0.87 mm, and 4.05 ± 0.89 mm for group I and II, respectively. Regarding vertical heights, obtained mean values were 4.75 ± 0.97 mm and 3.70 ± 0.92 mm for group I and group II, respectively. Conclusion: Within the limitations of this study, connective tissue graft proposed significantly more improvement as compare to connective tissue graft in pouch.

  6. The initial instability of cemented and non-cemented femoral stems fixated with a bone grafting technique

    NARCIS (Netherlands)

    Schreurs, B.W.; Huiskes, H.W.J.; Slooff, T.J.J.H.

    1994-01-01

    To reconstruct intramedullary bone stock in revision surgery of failed total hip arthroplasties, a method was developed using impacted trabecular bone grafts. In an in vitro model with femora of the goat, the initial stabilities of both cemented and non-cemented hydroxylapatite-coated stems in this

  7. Predictors of unsuccessful outcome in cemented femoral revisions using bone impaction grafting; Cox regression analysis of 208 cases.

    Science.gov (United States)

    Te Stroet, Martijn A J; Rijnen, Wim H C; Gardeniers, Jean W M; Schreurs, B Willem; Hannink, Gerjon

    2016-09-29

    Despite improvements in the technique of femoral impaction bone grafting, reconstruction failures still can occur. Therefore, the aim of our study was to determine risk factors for the endpoint re-revision for any reason. We used prospectively collected demographic, clinical and surgical data of all 202 patients who underwent 208 femoral revisions using the X-change Femoral Revision System (Stryker-Howmedica), fresh-frozen morcellised allograft and a cemented polished Exeter stem in our department from 1991 to 2007. Univariable and multivariable Cox regression analyses were performed to identify potential factors associated with re-revision. The mean follow-up was 10.6 (5-21) years. The cumulative re-revision rate was 6.3% (13/208). After univariable selection, sex, age, body mass index (BMI), American Association of Anesthesiologists (ASA) classification, type of removed femoral component, and mesh used for reconstruction were included in multivariable regression analysis.In the multivariable analysis, BMI was the only factor that was significantly associated with the risk of re-revision after bone impaction grafting (BMI ≥30 vs. BMI <30, HR = 6.54 [95% CI 1.89-22.65]; p = 0.003). BMI was the only factor associated with the risk of re-revision for any reason. Besides BMI also other factors, such as Endoklinik score and the type of removed femoral component, can provide guidance in the process of preclinical decision making. With the knowledge obtained from this study, preoperative patient selection, informed consent, and treatment protocols can be better adjusted to the individual patient who needs to undergo a femoral revision with impaction bone grafting.

  8. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  9. Development and validation of technique for in-vivo 3D analysis of cranial bone graft survival

    Science.gov (United States)

    Bernstein, Mark P.; Caldwell, Curtis B.; Antonyshyn, Oleh M.; Ma, Karen; Cooper, Perry W.; Ehrlich, Lisa E.

    1997-05-01

    Bone autografts are routinely employed in the reconstruction of facial deformities resulting from trauma, tumor ablation or congenital malformations. The combined use of post- operative 3D CT and SPECT imaging provides a means for quantitative in vivo evaluation of bone graft volume and osteoblastic activity. The specific objectives of this study were: (1) Determine the reliability and accuracy of interactive computer-assisted analysis of bone graft volumes based on 3D CT scans; (2) Determine the error in CT/SPECT multimodality image registration; (3) Determine the error in SPECT/SPECT image registration; and (4) Determine the reliability and accuracy of CT-guided SPECT uptake measurements in cranial bone grafts. Five human cadaver heads served as anthropomorphic models for all experiments. Four cranial defects were created in each specimen with inlay and onlay split skull bone grafts and reconstructed to skull and malar recipient sites. To acquire all images, each specimen was CT scanned and coated with Technetium doped paint. For purposes of validation, skulls were landmarked with 1/16-inch ball-bearings and Indium. This study provides a new technique relating anatomy and physiology for the analysis of cranial bone graft survival.

  10. Neo-glans reconstruction for penile cancer: Description of the primary technique using autologous testicular tunica vaginalis graft

    Directory of Open Access Journals (Sweden)

    Peter Weibl

    2018-06-01

    Neo-glans reconstruction with TV coverage may be another promising alternative, which certainly requires further evaluation. We believe that the donor-site associated morbidity is minimal when compared to other harvesting sites. However, this is just an assumption, because direct comparison data on grafting techniques and neo-glans reconstruction are not available. Nevertheless, we think that for re-do procedures a standardised approach using a STSG technique should be the treatment method of choice.

  11. Acid effects in the styrene comonomer technique for radiation grafting to wool

    International Nuclear Information System (INIS)

    Garnett, J.L.; Kenyon, R.S.

    1977-01-01

    Two processes are thought to contribute to the grafting of monomers to wool in the presence of acid under the influence of ionizing radiation. At temperatures of 45 0 C, acid alone will catalyze grafting to wool over a period of 18 hr and at much slower rates at room temperature. However, cellulose and polyolefins do not readily graft at these temperatures by acid-catalyzed process alone, radiation is also necessary. It is thought that in grafting to wool the radiation chemistry mechanisms and the mechanical swelling of acid both contribute appreciably to the radiation copolymerization; but with cellulose and the polyolefins, where acid-catalyzed grafting is approximately zero, the radiation process predominates

  12. Impact of smoking on early clinical outcomes in patients undergoing coronary artery bypass grafting surgery

    OpenAIRE

    Ji, Qiang; Zhao, Hang; Mei, YunQing; Shi, YunQing; Ma, RunHua; Ding, WenJun

    2015-01-01

    Background To evaluate the impact of persistent smoking versus smoking cessation over one month prior to surgery on early clinical outcomes in Chinese patients undergoing isolated coronary artery bypass grafting (CABG) surgery in a retrospective study. Methods The peri-operative data of consecutive well-documented patients undergoing isolated CABG surgery from January 2007 to December 2013 were investigated and retrospectively analyzed. All included patients were divided into either a non-smo...

  13. Urinary tract infection in renal transplant recipients: incidence, risk factors, and impact on graft function.

    Science.gov (United States)

    Camargo, L F; Esteves, A B A; Ulisses, L R S; Rivelli, G G; Mazzali, M

    2014-01-01

    Urinary tract infection (UTI) is the most common infection posttransplant. However, the risk factors for and the impact of UTIs remain controversial. The aim of this study was to identify the incidence of posttransplant UTIs in a series of renal transplant recipients from deceased donors. Secondary objectives were to identify: (1) the most frequent infectious agents; (2) risk factors related to donor; (3) risk factors related to recipients; and (4) impact of UTI on graft function. This was a retrospective analysis of medical records from renal transplant patients from January to December 2010. Local ethics committee approved the protocol. The incidence of UTI in this series was 34.2%. Risk factors for UTI were older age, (independent of gender), biopsy-proven acute rejection episodes, and kidneys from deceased donors (United Network for Organ Sharing criteria). For female patients, the number of pretransplant pregnancies was an additional risk factor. Recurrent UTI was observed in 44% of patients from the UTI group. The most common infectious agents were Escherichia coli and Klebsiella pneumoniae, for both isolated and recurrent UTI. No difference in renal graft function or immunosuppressive therapy was observed between groups after the 1-year follow-up. In this series, older age, previous pregnancy, kidneys from expanded criteria donors, and biopsy-proven acute rejection episodes were risk factors for posttransplant UTI. Recurrence of UTI was observed in 44%, with no negative impact on graft function or survival. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. The threshold force required for femoral impaction grafting in revision hip surgery.

    LENUS (Irish Health Repository)

    Flannery, Olivia M

    2010-06-01

    BACKGROUND AND PURPOSE: Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS: Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow femurs were impacted with morselized bone chips and an increasing force was applied until the femur fractured. This allowed a threshold force to be established. 5 other femurs were impacted to this force and an Exeter stem was cemented into the neomedullary canal. A 28-mm Exeter head was attached and loaded by direct contact with a hydraulic testing machine. Axial cyclic loading was performed and the position sensor of the hydraulic testing machine measured the prosthetic head subsidence. RESULTS: 29 tests were completed successfully. The threshold force was found to be 4 kN. There was no statistically significant correlation between the load at fracture and the cortex-to-canal ratio or the bone mineral density. Following impaction with a maximum force of 4 kN, the average axial subsidence was 0.28 mm. INTERPRETATION: We achieved a stable construct without fracture. Further studies using human cadaveric femurs should be done to determine the threshold force required for femoral impaction grafting in revision hip surgery.

  15. Autologous Cricoid Cartilage as a Graft for Airway Reconstruction in an Emergent Technique - A Case Report

    Directory of Open Access Journals (Sweden)

    Farzad Izadi

    2016-03-01

    Full Text Available Introduction: Laryngotracheal stenosis can be caused after traumatic injuries to the neck from the subglottic larynx to the trachea. Patients with laryngotracheal stenosis often need a tracheotomy and occasionally may become tracheotomy dependent. Different procedures have been described for the management of these lesions. Management options include techniques of endoscopic dilation, laser resection, laryngo-fissure, and an innovative array of plastic reconstructions with or without the use of stents.   Case Report:This paper presents airway reconstruction in a young patient with severe subglottic stenosis due to a blunt trauma to the neck, who was treated using particles of an autologous fractured cricoid cartilage as the source for airway augmentation. An incision was made in the anterior midline of the cricoid lamina and deepened through the scar tissue to the posterior cricoid lamina. Then two lateral incisions (right & left were made in the cricoid lamina and fractured cartilage particles and the scar tissue were removed via these two lateral incisions. The mucosal lining at the right and left of the midline incision, after debulking, were sutured to a lateral position. Thereafter three cartilage particles were used to reconstruct the anterior cricoid lamina and augment the lumen.   Conclusion:  It is worth to mention that an autologus cartilage graft can be used for certain cases with traumatic airway stenosis. Further follow up and more patients are needed to approve this method of reconstructive surgery in emergent situations.

  16. The Impact of Alveolar Bone Grafting on Cleft Lip and Palate: A literature review

    Directory of Open Access Journals (Sweden)

    Toby J. Gillgras

    2014-09-01

    Full Text Available Introduction: Alveolar bone grafting between the ages of nine years to eleven years is a routine procedure for children with a cleft involving the alveolus. It is believed to encourage dental development and subsequent treatment within the region of the cleft and to improve nasolabial aesthetics. The aims of this article are to review the literature as to its impact on dental development and subsequent treatment, nasolabial aesthetics and the nasal airway. Methods: An electronic search was conducted using Medline and Embase, with no restriction as to date of publication, study design or language. Results: The results suggest that secondary alveolar bone grafting when carried out at the appropriate time has significant benefits and for subsequent dental treatment, often allows space closure of adjacent teeth and eliminating the need for a prosthesis. Although it has an effect of nasolabial aesthetics it is equivocal as to whether this improves nasolabial aesthetics or merely improves the likelihood of aesthetic improvement of subsequent nasal surgery. Nasal obstruction is a significant issue in patients with cleft lip and palate with smaller nasal volume and mean cross-sectional area. It would appear that there is a reduction in the growth of the airway after an age that approximates to the timing for secondary alveolar grafting, although there are no studies that can refute or confirm its actual impact. Conclusions: Alveolar bone grafting between the ages of 9 – 11 years appears to produce clear benefits in terms of dental development and subsequent dental treatment. Its impact on nasolabial aesthetics appear equivocal as although there are changes in some landmarks post-surgery it is unclear as to whether these changes produce a benefit in terms of aesthetics for the patient.

  17. Study on grafting of monomer onto natural rubber latex by radiation technique

    International Nuclear Information System (INIS)

    Nguyen Tan Man; Le Hai; Tran Thi Tam; Le Huu Tu, Pham Thi Sam; Dao Minh Phuong; Ha Thuc Huy

    2004-01-01

    Radiation vulcanization of natural rubber latex has been extensively developed through programmers assisted by the IAEA and UNDP under RCA in Asia and Pacific Region. R-D has been done in most of the Member States with technical assistance from Japan's Takasaki Radiation Chemistry Establishment. Radiation vulcanized natural rubber latex (RVNRL) has many advantages over the conventional sulfur vulcanized latex, such as absence of nitrosamine and low cytotoxicity. Radiation crosslinking is a room temperature process, itself an important cost advantage, it is easily controlled and desired extend of crosslinking is easily achieved by controlling the dose (irradiation time). Disadvantages of RVNRL to be improved are poor physical properties of film such as low tensile strength and tear strength. The research groups of Japan, Thailand and Indonesia concentrated on the improvement of physical properties of RVNRL using radiation grafted PMMA as additive [2]. F. Sundardi and W. Sofiarti have reported that tensile strength and hardness increased by radiation grafting of styrene onto NR [5]. Ono et al have reported the grafting of MMA onto NR by gamma irradiation at a dose of 5 kGy for producing thermoplastic elastomers [4]. The objective of this project is to report the results of studies of radiation graft-copolymerization of methyl methacrylate (MMA) or styrene (St) onto natural rubber latex in order to improve their physico-mechanical properties and evaluation of grafted material using Small-Angle Neutron Scattering through FNCA Project. The grafting degree of MMA and St onto NR increased with the increase of irradiation dose and monomer concentration. The alteration of grafted products structure was determined by IR method. Tensile strength, Shore A hardness, 100% modulus of grafted products increased with the increase of monomer concentration and irradiation dose while elongation at break decreased. The grafted products were characterized by Transmission Electron

  18. A new strategy of fingertip reattachment: sequential use of microsurgical technique and pocketing of composite graft.

    Science.gov (United States)

    Kim, K S; Eo, S R; Kim, D Y; Lee, S Y; Cho, B H

    2001-01-01

    Many methods have been used to reattach amputated fingertips. Of these methods, microsurgery has been accepted as the procedure of choice because the defining characteristic of a microsurgically replanted finger is that its surival in the recipient bed is predicated on functioning intravascular circulation. Although considerable progress has been made in the techniques for microvascular replantation of amputated fingers, the replantation of an amputated fingertip is difficult because digital arteries branch into small arteries. This is in addition to digital veins that run from both sides of the nail bed to the median dorsal sides, which are difficult to separate from the immobile soft tissue. Furthermore, even with the most technically skilled microsurgeon, replantation failure often occurs, especially in severe injury cases. Therefore, the technique is not the only protection against failure, and a new strategy of fingertip reattachment is needed. From March of 1997 to December of 1999, 12 fingers of 11 patients with zone 1 or zone 2 fingertip amputations that were reattached microsurgically but were compromised were deepithelialized, reattached, and then inserted into the abdominal pocket. All had been complete amputations with crushing injuries. Approximately 3 weeks later, the fingers were depocketed and covered with a skin graft. Of the 12 fingers, 7 survived completely and 3 had partial necrosis on less than one-third the volume of the amputated part. The complete survival rate was approximately 58 percent. The results of the above 10 fingers were satisfactory from both functional and cosmetic aspects. The authors believe that this high success rate was achieved because the deepithelialized finger pulp was placed in direct contact with the deep abdominal fascia, which was equipped with plentiful vascularity, not subcutaneous fat. In addition, the pocketing was performed promptly before necrosis of the compromised fingertip occurred. From the results of this

  19. Vaginal-sparing ventral buccal mucosal graft urethroplasty for female urethral stricture: A novel modification of surgical technique.

    Science.gov (United States)

    Hoag, Nathan; Gani, Johan; Chee, Justin

    2016-07-01

    To present a novel modification of surgical technique to treat female urethral stricture (FUS) by a vaginal-sparing ventral buccal mucosal urethroplasty. Recurrent FUS represents an uncommon, though difficult clinical scenario to manage definitively. A variety of surgical techniques have been described to date, yet a lack of consensus on the optimal procedure persists. We present a 51-year-old female with urethral stricture involving the entire urethra. Suspected etiology was iatrogenic from cystoscopy 17 years prior. Since then, the patient had undergone at least 25 formal urethral dilations and periods of self-dilation. In lithotomy position, the urethra was dilated to accommodate forceps, and ventral urethrotomy carried out sharply, exposing a bed of periurethral tissue. Buccal mucosa was harvested, and a ventral inlay technique facilitated by a nasal speculum, was used to place the graft from the proximal urethra/bladder neck to urethral meatus without a vaginal incision. Graft was sutured into place, and urethral Foley catheter inserted. The vaginal-sparing ventral buccal mucosal graft urethroplasty was deemed successful as of last follow-up. Flexible cystoscopy demonstrated patency of the repair at 6 months. At 10 months of follow-up, the patient was voiding well, with no urinary incontinence. No further interventions have been required. This case describes a novel modification of surgical technique for performing buccal mucosal urethroplasty for FUS. By avoiding incision of the vaginal mucosa, benefits may include reduced: morbidity, urinary incontinence, and wound complications including urethro-vaginal fistula.

  20. Lingual mucosal graft two-stage Bracka technique for redo hypospadias repair

    Directory of Open Access Journals (Sweden)

    Ahmed Sakr

    2017-09-01

    Conclusion: Lingual mucosa is a reliable and versatile graft material in the armamentarium of two-stage Bracka hypospadias repair with the merits of easy harvesting and minor donor-site complications.

  1. Development of mechanoluminescence technique for impact studies

    International Nuclear Information System (INIS)

    Chandra, B.P.

    2011-01-01

    A new technique called, mechanoluminescence technique, is developed for measuring the parameters of impact. This technique is based on the phenomenon of mechanoluminescence (ML), in which light emission takes place during any mechanical action on solids. When a small solid ball makes an impact on the mechanoluminescent thin film coated on a solid, then initially the elastico ML (EML) intensity increases with time, attains a maximum value I m at a particular time t m , and later on it decreases with time. The contact time T c of ball, can be determined from the relation T c =2t c , where t c is the time at which the EML emission due to compression of the sample becomes negligible. The area from where the EML emission occurs can be taken as the contact area A c . The maximum compression h is given by h=A c /(πr), where r is the radius of the impacting ball, and thus, h can be determined from the known values of A c and r. The maximum force at contact is given by F m =(2mU 0 )/T c , where m is the mass of the impacting ball and U 0 is the velocity of the ball at impact. The maximum impact stress σ m can be obtained from the relation, σ m =F m /A c =(2mU 0 )/(T c A c ). Thus, ML provides a real-time technique for determining the impact parameters such as T c , A c , h, F m and σ m . Using the ML technique, the impact parameters of the SrAl 2 O 4 :Eu film and ZnS:Mn coating are determined. The ML technique can be used to determine the impact parameters in the elastic region and plastic region as well as fracture. ML can also be used to determine the impact parameters for the collision between solid and liquid, if the mechanoluminescent material is coated on the surface of the solid. The measurement of fracto ML in microsecond and nanosecond range may provide a tool for studying the fragmentations in solids by the impact. Using the fast camera the contact area and the depth of compression can be determined for different intervals of time. - Research highlights: → A

  2. Antimicrobial-impregnated dressing combined with negative-pressure wound therapy increases split-thickness skin graft engraftment: a simple effective technique.

    Science.gov (United States)

    Wu, Cheng-Chun; Chew, Khong-Yik; Chen, Chien-Chang; Kuo, Yur-Ren

    2015-01-01

    Immobilization and adequate surface contact to wounds are critical for skin graft take. Techniques such as the tie-over dressing, cotton bolster, and vacuum-assisted closure are used to address this, but each has its limitations. This study is designed to assess the effect of antimicrobial-impregnated dressing (AMD) combined with negative-pressure wound therapy (NPWT) on skin graft survival. Retrospective case-control study : Patients with chronic or contaminated wounds treated with split-thickness skin graft. A broad spectrum of wounds was included, from causes such as trauma, burns, chronic diabetic ulcers, and infection. Antimicrobial-impregnated dressing, which contains 0.2% polyhexamethylene biguanide, with NPWT MAIN OUTCOME MEASURE:: Success of skin graft : In the AMD group, all skin grafts achieved 100% take without secondary intervention. No infection or graft failure was observed in any patients, and no complications, such as hematoma or seroma formation, were noted, although in the control group partial loss of skin grafts was noted in 3 patients. Infection and inadequate immobilization were thought to be the main reasons. There were no hematoma or seroma formations in the control group. Use of an AMD dressing with NPWT after split-thickness skin grafting can be an effective method to ensure good graft to wound contact and enhances skin graft take in chronic and contaminated wounds.

  3. Polyurethane Foam Wound Dressing Technique for Areola Skin Graft Stabilization and Nipple Protection After Nipple-Areola Reconstruction.

    Science.gov (United States)

    Satake, Toshihiko; Muto, Mayu; Nagashima, Yu; Haga, Shoko; Homma, Yuki; Nakasone, Reiko; Kadokura, Marina; Kou, Seiko; Fujimoto, Hiroshi; Maegawa, Jiro

    2018-04-01

    We describe a new wound management technique using a soft dressing material to stabilize the areola skin graft and protect the nipple after nipple-areola reconstruction at the final stage of breast reconstruction. We introduced a center-fenestrated multilayered hydrocellular polyurethane foam dressing material that provides adequate pressure and retains a moist environment for a smooth skin graft "take." Moreover, the reconstructed nipple can be monitored at any time through the fenestrated window for adequate blood circulation. Altogether, this simple and inexpensive wound dressing technique improves the clinical outcome. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Does Off-Pump Coronary Artery Bypass Grafting Negatively Impact Long-Term Survival and Freedom from Reintervention?

    Directory of Open Access Journals (Sweden)

    Shahzad G. Raja

    2013-01-01

    Full Text Available Recently published evidence has raised concerns about worse late mortality and increasing need for reintervention after off-pump coronary artery bypass grafting. We undertook this study to assess the impact of off-pump coronary artery bypass grafting on survival and freedom from reintervention at 10 years. From January 2002 to December 2002, 307 consecutive patients who had isolated multivessel off-pump coronary artery bypass grafting at our institution were compared to a control group of 397 patients that underwent multivessel on-pump coronary artery bypass grafting during the same period. In addition, univariate and risk-adjusted comparisons between the two groups were performed at 10 years. Kaplan-Meier survival was similar for the two cohorts. After adjusting for clinical covariates, off-pump coronary artery bypass grafting did not emerge as a significant independent predictor of long-term mortality (Hazard Ratio 0.91; 95% Confidence Interval 0.70–1.12, readmission to hospital for cardiac cause (Hazard Ratio 0.96; 95% Confidence Interval 0.78–1.10, or the need for reintervention (Hazard Ratio 0.93; 95% Confidence Interval 0.87–1.05. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting does not adversely impact survival or freedom from reintervention at a 10-year follow-up.

  5. [Comparison of the grafting technique in treatment of thoracolumbar burst fractures:transpedicular intracorporeal versus posterolateral].

    Science.gov (United States)

    Li, Li; Shi, Ya-Min; Hou, Shu-Xun; Wang, Hua-Dong; Guo, Ji-Dong

    2011-02-01

    To retrospectively investigate the outcome of transpedicular intracorporeal grafting and posterolateral grafting in treatment of thoracolumbar burst fractures. Forty-six patients treated with transpedicular intracorporeal grafting from January 1999 to December 2009 and followed up for 19-119 months (average 67 ± 13 months) were reviewed retrospectively, and were compared with 18 patients who had underwent posterolateral fusion during the same period through radiographic analysis. Radiographic measurements included Cobb angle, vertebral wedge angle (VWA), ratio between anterior and posterior vertebral height (APHR), upper inter-vertebral angle, lower inter-vertebral angle on X-ray, CT and MRI. In transpedicular intracorporeal grafting group, the VWA was corrected from 27.2° ± 6.5° to 7.0° ± 3.0° and the APHR from (53.3 ± 11.8)% to (92.3 ± 2.4)%. In posterolateral fusion group, the VWA was corrected from 23.9° ± 4.4° to 8.8° ± 2.1° and the APHR from (60.7 ± 10.0)% to (88.5 ± 3.3)%. Transpedicular intracorporeal grafting group showed better postoperative correction results than posterolateral fusion group (P < 0.05), and had less loss of correction of Cobb angle, VWA and APHR at final follow-up (P < 0.05). The transpedicular intracorporeal grafting can improve injured vertebral body morphology recovery better than posterolateral bone grafting, but can not prevent the late loss of correction after implant removal.

  6. Ureteric complications in live related donor renal transplantation - impact on graft and patient survival

    Directory of Open Access Journals (Sweden)

    A Srivastava

    2004-01-01

    Full Text Available Objective : The study was performed with an aim to determine the incidence of ureteric complications in live related donor renal transplantation, and to study the effect of ureteric complications on long term graft and patient survival. Patients And Methods: Records of 1200 consecutive live related renal transplants done from 1989-2002 were reviewed. Twenty-six ureteric complications were noted to occur and treatment modalities employed were documented. In the non complication group sufficient data for evaluation was available in 867 patients. Survival analysis were performed using Kaplan-Meier techniques. Results: The overall incidence of urological complications is 2.9%. Complications occurred at a mean interval of 31.9 days after renal transplantation. Ureteric complications occurred in 2% patients with stented and 7.7% patients with non stented anastomosis (p=0.001. Mean follow up following renal transplantation was 37.4 months. Survival analysis showed that ureteric complications did not increase the risk of graft fai lu re or patient death. Conclusions: Ureteric complications in live related donor renal transplantation occurred in 2.9 % patients and did not impair graft and patient survival.

  7. The Impact of Health Care Appointment Non-Adherence on Graft Outcomes in Kidney Transplantation.

    Science.gov (United States)

    Taber, David J; Fleming, James N; Fominaya, Cory E; Gebregziabher, Mulugeta; Hunt, Kelly J; Srinivas, Titte R; Baliga, Prabhakar K; McGillicuddy, John W; Egede, Leonard E

    2017-01-01

    Non-adherence to medication is a well-studied and known cause of late allograft loss, but it is difficult to measure and prospectively monitor. The aim of this study was to assess if appointment non-adherence was correlated with medication non-adherence and a predictor of graft outcomes. This was a longitudinal cohort study that used the National United States Renal Data System and veterans affairs health records data with time-to-event analyses conducted to assess the impact on graft and patient survival. The number of transplants that were included in the analysis was 4,646 (3,656 with complete records); 14.6% of patients had an appointment no show rate of ≥12% (non-adherence). Appointment and medication non-adherence were highly correlated and both were significant independent predictors of outcomes. Those with appointment non-adherence had 1.5 times the risk of acute rejection (22.0 vs. 14.7%, p adherence; those with appointment and medication non-adherence were at very high risk of graft loss (aHR 4.18, 95% CI 3.39-5.15, p adherence (aHR 1.39, 95% CI 0.97-2.01, p = 0.0766) or only medication non-adherence (aHR 2.44, 95% CI 2.11-2.81, p adherence to health care appointments is a significant and independent risk factor for graft loss. © 2016 S. Karger AG, Basel.

  8. PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Auler José

    2011-09-01

    Full Text Available Abstract Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP, followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP, associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.

  9. Studies in Fat Grafting: Part I. Effects of Injection Technique on in vitro Fat Viability and in vivo Volume Retention

    Science.gov (United States)

    Chung, Michael T.; Paik, Kevin J.; Atashroo, David A.; Hyun, Jeong S.; McArdle, Adrian; Senarath-Yapa, Kshemendra; Zielins, Elizabeth R.; Tevlin, Ruth; Duldulao, Chris; Hu, Michael S.; Walmsley, Graham G.; Parisi-Amon, Andreina; Momeni, Arash; Rimsa, Joe R.; Commons, George W.; Gurtner, Geoffrey C.; Wan, Derrick C.; Longaker, Michael T.

    2014-01-01

    Background Fat grafting has become increasingly popular for the correction of soft tissue deficits at many sites throughout the body. Long-term outcomes, however, depend on delivery of fat in the least traumatic fashion to optimize viability of the transplanted tissue. In this study, we compare the biologic properties of fat following injection using two methods. Methods Lipoaspiration samples were obtained from five female donors and cellular viability, proliferation, and lipolysis were evaluated following injection using either a modified Coleman technique or an automated, low shear device. Comparisons were made to minimally processed, uninjected fat. Volume retention was also measured over twelve weeks following injection of fat under the scalp of immunodeficient mice using either the modified Coleman technique or the Adipose Tissue Injector. Finally, fat grafts were analyzed histologically. Results Fat viability and cellular proliferation were both significantly greater with the Adipose Tissue Injector relative to injection with the modified Coleman technique. In contrast, significantly less lipolysis was noted using the automated device. In vivo fat volume retention was significantly greater than with the modified Coleman technique at 4, 6, 8, and 12 week time points. This corresponded with significantly greater histological scores for healthy fat and lower scores for injury following injection with the device. Conclusions Biological properties of injected tissues reflect how disruptive and harmful techniques for placement of fat may be, and our in vitro and in vivo data both support the use of the automated, low shear devices compared to the modified Coleman technique. PMID:24622574

  10. Endoscopic diode laser welding of mucosal grafts on the larynx: a new technique.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Rebeiz, E E; Perrault, D F; Shapshay, S M

    1995-01-01

    Epithelial coverage of a laryngotracheal wound is an important factor in preventing stenosis, and endoscopic transplantation of a free mucosal graft without stents or sutures would be a significant therapeutic advance. In vitro and in vivo canine studies were performed to explore the feasibility of transplantation with a low-power diode laser (400 mW) enhanced by indocyanine green dye-doped albumin. The tensile strength of graft adherence in 10 cadaver larynges was strong (35.25 +/- 10.39 g). Survival studies in live canine models with a specially designed endoscopic instrument set showed excellent healing at 6, 14, and 28 days. Healing was documented with photography and by histologic examination. Successful endoscopic transplantation of a free mucosal graft should improve results of treatment for laryngotracheal stenosis and laryngeal reconstructive surgery.

  11. Preliminary in Vivo Evaluation of a Hybrid Armored Vascular Graft Combining Electrospinning and Additive Manufacturing Techniques

    Directory of Open Access Journals (Sweden)

    Cristiano Spadaccio

    2016-01-01

    Full Text Available In this study, we tested in vivo effectiveness of a previously developed poly-L-lactide/poly-8-caprolactone armored vascular graft releasing heparin. This bioprosthesis was designed in order to overcome the main drawbacks of tissue-engineered vascular grafts, mainly concerning poor mechanical properties, thrombogenicity, and endothelialization. The bioprosthesis was successfully implanted in an aortic vascular reconstruction model in rabbits. All grafts implanted were patent at four weeks postoperatively and have been adequately populated by endogenous cells without signs of thrombosis or structural failure and with no need of antiplatelet therapy. The results of this preliminary study might warrant for further larger controlled in vivo studies to further confirm these findings.

  12. Reducing Postoperative Pterygium Recurrence: Comparison of Free Conjunctival Auto-Graft and Conjunctival Rotation Flap Techniques

    International Nuclear Information System (INIS)

    Akhter, W.; Tayyab, A.; Kausar, A.; Masrur, A.

    2014-01-01

    Objective: To compare the recurrence of pterygium between free conjunctival auto-graft and conjunctival rotation flap following simple surgical excision of pterygium. Study Design: Quasi-experimental study. Place and Duration of Study: Shifa Foundation Community Health Clinic, Shifa College of Medicine, Islamabad, from January to November 2012. Methodology: Fifty seven cases aged above 18 years, with a pterygium corneal encroachment of 2 mm which was responsible for visual disability or was cosmetically undesirable were recruited for the study and randomly assigned to conjunctival auto-graft group and conjunctival rotation flap group. Cases with a history of glaucoma or glaucoma suspect, prior pterygium surgery, pterygium with concurrent ocular surface and lid disease, conjunctival inflammation and scarring, pseudo-pterygium or collagen vascular disease were excluded. After simple pterygium excision conjunctival auto-graft group (n=26) cases received a free conjunctival flap was transplanted, while conjunctival rotation flap group (n=31) cases received a conjunctival rotation flap. All cases were followed-up for 6 months after surgery for recurrence and complications. Frequency distribution and significance of association of recurrence using Fisher's exact test and Mann- Whitney U-test was carried out using Statistical Package for Social Sciences (SPSS) version 20. Results: The median (and inter-quartile range) age and surgery duration in conjunctival auto-graft group and conjunctival rotation flap group were 60 (51.50 - 63.00) and 57 (45.00 - 60.00) years, 28.50 (27.00 - 30.50) and 16.00 (15.00 - 17.00) minutes respectively. Recurrence was seen in 2 (7.96%) and 3 (9.76%) cases in auto-graft and rotation flap groups respectively. No significant difference was seen in postoperative complications between the two groups (p=0.60). Conclusion: The surgical time for conjunctival rotation flap procedure is less as compared to free auto-graft, while their recurrence and

  13. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by 133Xe clearance technique

    International Nuclear Information System (INIS)

    Basa, S.; Ercan, M.T.; Aras, T.; Araz, K.

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of 133 Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), 133 Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2±12.9 and 58.3±3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4±3.2 and 21.7±15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2±16.9 ml/100 g/min) and above (63.9±9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing. (author)

  14. Preparation of antifouling ultrafiltration membranes via irradiation induced graft polymerization technique

    International Nuclear Information System (INIS)

    Deng Bo; Liu Zhognying; Lu Xiaofeng; Li Jingye; Yang Xuanxuan; Yu Ming; Zhang Bowu

    2010-01-01

    PVDF powders were irradiated in air at dose of 15 kGy by using gamma-rays. Macromolecular peroxides transformed from free radicals in the irradiated PVDF powders in air can be preserved for long-term at appropriate temperature stably. By mixing acrylic monomers with irradiated PVDF powders then the graft polymerization can be initiated by heating. Then a series of hydrophilic ultrafiltration (UF) membranes were fabricated by dissolving the PVDF-g-PAAc powders in the NMP under phase inversion method. The antifouling performances of UF membranes cast from virgin and grafted PVDF powders were compared. (authors)

  15. Skin and Composite Grafting Techniques in Facial Reconstruction for Skin Cancer.

    Science.gov (United States)

    Brenner, Michael J; Moyer, Jeffrey S

    2017-08-01

    Skin and composite grafting provide effective resurfacing and reconstruction for cutaneous defects after excision of the malignancy. The goal is to restore a natural appearance and function while preventing distortion of the eyelid, nose, or lips. With careful planning and attention to aesthetic subunits, the surgeon can camouflage incisions and avoid blunting aesthetically sensitive sulci. The surgical plan is also informed by the pathology, as basal or squamous cell carcinomas removed by Mohs micrographic excision have different prognostic and logistical considerations from melanoma. Skin and composite grafting are useful as stand-alone procedures or may complement local flaps and other soft tissue reconstructions. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Reconstruction of an amputated glans penis with a buccal mucosal graft: case report of a novel technique.

    Science.gov (United States)

    Aboutaleb, Hamdy

    2014-12-01

    Penile amputation is a rare catastrophe and a serious complication of circumcision. Reconstruction of the glans penis may be indicated following amputation. Our report discusses a novel technique for reconfiguration of an amputated glans penis 1 year after a complicated circumcision. A 2-year-old male infant presented to us with glans penis amputation that had occurred during circumcision 1 year previously. The parents complained of severe meatal stenosis with disfigurement of the penis. Penis length was 3 cm. Complete penile degloving was performed. The distal part of the remaining penis was prepared by removing fibrous tissue. A buccal mucosal graft was applied to the distal part of the penis associated with meatotomy. The use of a buccal mucosal graft is a successful and simple procedure with acceptable cosmetic and functional results for late reconfiguration of the glans penis after amputation when penile size is suitable.

  17. Transplantation and microsurgical anastomosis of free omental grafts: experimental animal model of a new operative technique in dogs.

    Science.gov (United States)

    Pap-Szekeres, Jozsef; Cserni, Gabor; Furka, Istvan; Svebis, Mihaly; Cserni, Tamas; Brath, Endre; Nemeth, Norbert; Miko, Iren

    2003-01-01

    Our objective was the elaboration of a new animal model for the free transplantation of an omental flap and the examination of its viability in dogs. The cooled omental flap from the abdomen was freely transplanted to the lateral cervical region, and its blood supply was established with microsurgical anastomoses. The technique was developed in 5 dogs, and short-term survival examinations were later carried out in 3 cases by means of this method. Postoperative viability was assessed by angiography, methylene blue testing, and histology. Of the 3 transplanted grafts, 2 still survived 1 week after the operation. For technical reasons, 1 flap thrombotized. For determination of the viability of the transplanted graft, histology proved best. Vital reactions, including granulation tissue and angiogenesis, were present on the histological slides. The short-term survival of an omental flap can be ensured with microsurgical transplantation in dogs. Copyright 2003 Wiley-Liss, Inc.

  18. Vaginal-sparing ventral buccal mucosal graft urethroplasty for female urethral stricture: A novel modification of surgical technique

    Directory of Open Access Journals (Sweden)

    Nathan Hoag

    2016-07-01

    Full Text Available Purpose: To present a novel modification of surgical technique to treat female urethral stricture (FUS by a vaginal-sparing ventral buccal mucosal urethroplasty. Recurrent FUS represents an uncommon, though difficult clinical scenario to manage definitively. A variety of surgical techniques have been described to date, yet a lack of consensus on the optimal procedure persists. Materials and Methods: We present a 51-year-old female with urethral stricture involving the entire urethra. Suspected etiology was iatrogenic from cystoscopy 17 years prior. Since then, the patient had undergone at least 25 formal urethral dilations and periods of self-dilation. In lithotomy position, the urethra was dilated to accommodate forceps, and ventral urethrotomy carried out sharply, exposing a bed of periurethral tissue. Buccal mucosa was harvested, and a ventral inlay technique facilitated by a nasal speculum, was used to place the graft from the proximal urethra/bladder neck to urethral meatus without a vaginal incision. Graft was sutured into place, and urethral Foley catheter inserted. Results: The vaginal-sparing ventral buccal mucosal graft urethroplasty was deemed successful as of last follow-up. Flexible cystoscopy demonstrated patency of the repair at 6 months. At 10 months of follow-up, the patient was voiding well, with no urinary incontinence. No further interventions have been required. Conclusions: This case describes a novel modification of surgical technique for performing buccal mucosal urethroplasty for FUS. By avoiding incision of the vaginal mucosa, benefits may include reduced: morbidity, urinary incontinence, and wound complications including urethro-vaginal fistula.

  19. Dorsal onlay (Barbagli technique) versus dorsal inlay (Asopa technique) buccal mucosal graft urethroplasty for anterior urethral stricture: a prospective randomized study.

    Science.gov (United States)

    Aldaqadossi, Hussein; El Gamal, Samir; El-Nadey, Mohamed; El Gamal, Osama; Radwan, Mohamed; Gaber, Mohamed

    2014-02-01

    To compare both the dorsal onlay technique of Barbagli and the dorsal inlay technique of Asopa for the management of long anterior urethral stricture. From January 2010 to May 2012, a total of 47 patients with long anterior urethral strictures were randomized into two groups. The first group included 25 patients who were managed by dorsal onlay buccal mucosal graft urethroplasty. The second group included 22 patients who were managed by dorsal inlay buccal mucosal graft urethroplasty. Different clinical parameters, postoperative complications and success rates were compared between both groups. The overall success rate in the dorsal onlay group was 88%, whereas in the dorsal inlay group the success rate was 86.4% during the follow-up period. The mean operative time was significantly longer in the dorsal onlay urethroplasty group (205 ± 19.63 min) than in the dorsal inlay urethroplasty group (128 ± 4.9 min, P-value <0.0001). The average blood loss was significantly higher in the dorsal onlay urethroplasty group (228 ± 5.32 mL) than in the dorsal inlay urethroplasty group (105 ± 12.05 mL, P-value <0.0001). The dorsal onlay technique of Barbagli and the dorsal inlay technique of Asopa buccal mucosal graft urethroplasty provide similar success rates. The Asopa technique is easy to carry out, provides shorter operative time and less blood loss, and it is associated with fewer complications for anterior urethral stricture repair. © 2013 The Japanese Urological Association.

  20. A new technique for augmentation phalloplasty: albugineal surgery with bilateral saphenous grafts--three years of experience.

    Science.gov (United States)

    Austoni, E; Guarneri, A; Cazzaniga, A

    2002-09-01

    Penile augmentation surgery is a highly controversial issue due to the low level of standardisation of surgical techniques. The aim of the study is to illustrate a new technique to solve the problem of enlarging the penis by means of additive surgery on the albuginea of the corpora cavernosa, guaranteeing a real increase in size of the erect penis. Between 1995 and 1997, 39 patients who requested an increase in the diameter of their penises underwent augmentation phalloplasty with bilateral saphena grafts. The patients considered eligible for surgery were patients with either hypoplasia of the penis or functional penile dysmorphophobia. All the patients included in our study presented normal erection at screening. The average penis diameter in a flaccid state and during erection was found to be 2.1cm (1.6-2.7 cm) and 2.9 cm (2.2-3.7 cm), respectively. Before surgery the patients were informed of the experimental nature of the surgical procedure. The increase in volume of the corpora cavernosa was achieved by applying saphena grafts to longitudinal openings made bilaterally in the albuginea along the whole length of the penis. No major complications and specifically no losses of sensitivity of the penis or erection deficiencies occurred during the post-operative follow-up period. All the patients resumed their sexual activity in 4 months. A measurement of the penile dimensions was carried out 9 months after surgery. No clinical meaningful increases in the diameter of the flaccid penis were documented. The average penis diameter during erection was found to be 4.2 cm (3.4-4.9) with post-surgery increases in diameter varying from 1.1 to 2.1cm (penlargement phalloplasty technique with albuginea surgery suggested by the authors definitely is indicated for increasing the volume of the corpora cavernosa during erection. Albuginea surgery with saphena grafts has been found to be free from aesthetic and functional complications with excellent patient satisfaction.

  1. Polymer Brush Grafted Nanoparticles and Their Impact on the Morphology Evolution of Polymer Blend Films

    Science.gov (United States)

    Chung, Hyun-Joong; Ohno, Kohji; Composto, Russell

    2013-03-01

    We present an novel pathway to control the location of nanoparticles (NPs) in phase-separating polymer blend films containing poly(methyl methacrylate) (PMMA) and poly(styrene-ran-acrylonitrile) (SAN). Because hydrophobic polymer phases have a small interfacial energy, ~1 mJ/m2, subtle changes in the NP surface functionality can be used to guide NPs to either the interface between immiscible polymers or into one of the phases. Based on this idea, we designed a class of NPs grafted with PMMA brushes. These PMMA brushes were grown from the NP surface by atom transfer radical polymerization (ATRP), which results in chains terminated with chlorine atoms. The chain end can be substituted with protons (H) by dehalogenation. As a result, the NPs are strongly segregated at the interface when grafted PMMA chains are short (Mn =1.8K) and the end group is Cl, whereas NPs partition into PMMA-rich phase when chains are long (Mn =160K) and/or when chains are terminated with hydrogen. The Cl end groups and shorter chain length cause an increase in surface energy for the NPs. The increase in surface energy of short-chained NPs can be attributed to (i) an extended brush conformation (entropic) and/or (ii) a high density of ``unfavorable'' end groups (enthalpic). Finally, the impact of NPs on the morphological evolution of the polymer blend films will be discussed. Ref: H.-J.Chung et al., ACS Macro Lett. 1(1), 252-256 (2012).

  2. The Impact of Cardiovascular Risk Factors on Graft Outcome Disparities in African American Kidney Transplant Recipients

    Science.gov (United States)

    Taber, David J; Hunt, Kelly J; Fominaya, Cory E; Payne, Elizabeth H; Gebregziabher, Mulugeta; Srinivas, Titte R; Baliga, Prabhakar K; Egede, Leonard E

    2016-01-01

    Although outcome inequalities for non-Hispanic Black (NHB) kidney transplant recipients are well documented, there is paucity in data assessing the impact of cardiovascular disease (CVD) risk factors on this disparity in kidney transplantation. This was a longitudinal study of a national cohort of veteran kidney recipients transplanted between Jan 2001 and Dec 2007. Data included baseline characteristics acquired through the USRDS linked to detailed clinical follow up information acquired through the VA electronic health records. Analyses were conducted using sequential multivariable modeling (Cox regression), incorporating blocks of variables into iterative nested models; 3,139 patients were included (2,095 NHW [66.7%] and 1,044 NHBs [33.3%]). NHBs had a higher prevalence of hypertension (100% vs. 99%, ptransplant diabetes (59% vs. 53%, pAdherence to medications used to manage CVD risk was significantly lower in NHBs. In the fully adjusted models, the independent risk of graft loss in NHBs was substantially reduced (unadjusted HR 2.00 vs. adjusted HR 1.49). CVD risk factors and control reduced the influence of NHB race by 9–18%. Similar trends were noted for mortality and estimates were robust across in sensitivity analyses. These results demonstrate that NHB kidney transplant recipients have significantly higher rates of CVD risk factors and reduced CVD risk control. These issues are likely partly related to medication non-adherence and meaningfully contribute to racial disparities for graft outcomes. PMID:27402921

  3. Bone Metabolism after Total Hip Revision Surgery with Impacted Grafting: Evaluation using H215O and [18F]fluoride PET; A Pilot Study

    NARCIS (Netherlands)

    Temmerman, Olivier; Raijmakers, Pieter; Heyligers, Ide; Comans, Emile; Lubberink, Mark; Teule, Gerrit; Lammertsma, Adriaan

    2008-01-01

    Purpose: To evaluate bone blood flow and bone formation in patients after total hip revision surgery with impacted bone grafting using H2 15O and [18F]fluoride positron emission tomography (PET). Procedures: To asses bone blood flow and bone metabolism in bone allograft after impaction grafting,

  4. Deepening Fornix Technique Using Central Split-Medium Thickness Skin Graft to Treat Contracted Anophthalmic Sockets.

    Science.gov (United States)

    AlHassan, Sultan; Galindo-Ferreiro, Alicia; Khandekar, Rajiv; AlShaikh, Osama; Schellini, Silvana Artioli

    2018-05-08

    The aim of thhis study was to present the outcomes of postauricular split-medium thickness skin graft (SMTSG) to treat anophthalmic sockets with contracted fornices. This case series enrolled patients with grade 2 or 3 anophthalmic sockets between 2015 and 2016. Data were collected on patient demographics, objective and subjective parameters preoperatively and 180 days postoperatively. Success of the surgery was graded on the height of the graft, the depth of the superior and inferior fornices, and presence/abscence of lagophthalmos, entropion, and ability to retain an external prosthesis. Eighteen patients were enrolled with a mean age of 35.9 ± 18 years. The median height of the graft was 22 mm (25% quartile = 18.75) when removed and 20 mm (25% quartile = 16) postoperatively. The median depth of the superior fornix was 6.5 mm (25% quartile = 4.5 mm) preoperatively and 10 mm (25% quartile = 8 mm) postoperatively (P = 0.5). The median inferior fornix depth was 7 mm (25% quartile = 3.5 mm) preoperatively and 8 mm (25% quartile = 5 mm) (P = 0.27) postoperatively. Preoperatively, there were 13 (72.2%) patients with lagophthalmos, 10 (44.4%) with entropion, 3 (37.5%) with poor prosthesis retention, and 5 (62.5%) who were unable to retain the prosthesis. Postoperatively, 7 (38.9%) patients had lagophthamos, 1 (5.6%) had entropion, and all the patients could retain the prosthesis. None of the sockets had a foul odor postoperatively. Postauricular SMTSG achieves successful outcomes for the treatment of contracted anophthalmic sockets, reshaping the anterior socket surface and deepening the fornices.

  5. Ventral inlay buccal mucosal graft urethroplasty: a novel surgical technique for the management of urethral stricture disease.

    Science.gov (United States)

    Kovell, Robert Caleb; Terlecki, Ryan Patrick

    2015-02-01

    To describe the novel technique of ventral inlay substitution urethroplasty for the management of male anterior urethral stricture disease. A 58-year-old gentleman with multifocal bulbar stricture disease measuring 7 cm in length was treated using a ventral inlay substitution urethroplasty. A dorsal urethrotomy was created, and the ventral urethral plated was incised. The edges of the urethral plate were mobilized without violation of the ventral corpus spongiosum. A buccal mucosa graft was harvested and affixed as a ventral inlay to augment the caliber of the urethra. The dorsal urethrotomy was closed over a foley catheter. No intraoperative or postoperative complications occurred. Postoperative imaging demonstrated a widely patent urethra. After three years of follow-up, the patient continues to do well with no voiding complaints and low postvoid residuals. Ventral inlay substitution urethroplasty appears to be a safe and feasible technique for the management of bulbar urethral strictures.

  6. Relative impact of human leukocyte antigen mismatching and graft ischemic time after lung transplantation.

    Science.gov (United States)

    Brugière, Olivier; Thabut, Gabriel; Suberbielle, Caroline; Reynaud-Gaubert, Martine; Thomas, Pascal; Pison, Christophe; Saint Raymond, Christel; Mornex, Jean-François; Bertocchi, Michèle; Dromer, Claire; Velly, Jean-François; Stern, Marc; Philippe, Bruno; Dauriat, Gaëlle; Biondi, Giuseppina; Castier, Yves; Fournier, Michel

    2008-06-01

    Recent data strongly suggest that human leukocyte antigen (HLA) mismatching has a negative impact on development of bronchiolitis obliterans syndrome (BOS) and survival after lung transplantation (LTx). Because HLA matching is sometimes achieved by extending ischemic time in other solid-organ transplantation models and ischemic time is a risk factor per se for death after LTx, we sought to compare the theoretical benefit of HLA matching with the negative impact of lengthened ischemic time. In this collaborative study we compared the relative impact of HLA mismatching and ischemic time on BOS and survival in 182 LTx recipients. Using multivariate analyses, we observed a lower incidence of BOS (hazard ratio [HR] = 1.70, 95% confidence interval [CI]: 1.1 to 2.7, p = 0.03) and enhanced survival (HR = 1.91, 95% CI: 1.24 to 2.92, p = 0.01) in patients with zero or one HLA-A mismatch compared with those having two HLA-A mismatches. This beneficial effect on survival was equivalent to a reduction of ischemic time of 168 minutes. We observed a reduced incidence of BOS and a better survival rate in patients well-matched at the HLA-A locus, associated with an opposite effect of an enhanced ischemic time. This suggests that graft ischemic time should be taken into account in future studies of prospective HLA matching in LTx.

  7. Hybrid endovascular stent-grafting technique for patent ductus arteriosus in an adult.

    Science.gov (United States)

    Kainuma, S; Kuratani, T; Sawa, Y

    2011-09-01

    A 51-year-old man was referred to our institution for patent ductus arteriosus (PDA) complicated by left ventricular dysfunction and pulmonary hypertension. Surgical closure of a PDA is usually carried out via a small posterior thoracotomy. However, thoracoscopic procedures are probably not appropriate in adults because of the frequency of calcification and the greater risk of rupture while ligating the ductus. To minimize surgical trauma, we used hybrid endovascular stent grafting combined with revascularization of the left subclavian artery, which enabled us to eliminate shunt flow to the pulmonary artery. At 11-month follow-up, the patient was asymptomatic and showed no complications. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Posterolateral Corner Reconstruction using the Anatomical Two-Tailed Graft Technique: Clinical Outcomes in the Multiligament Injured Knee.

    Science.gov (United States)

    Woodmass, Jarret M; Sanders, Thomas L; Johnson, Nick R; Wu, Isabella T; Krych, Aaron J; Stuart, Michael J; Levy, Bruce A

    2018-02-14

    Injury to the posterolateral corner (PLC) of the knee can lead to both varus and rotational instability. Multiple PLC reconstruction techniques have been described, including one-tailed graft (fibula-based constructs) or two-tailed graft (combined fibula- and tibia-based constructs). The purpose of our study was to evaluate the clinical outcomes of anatomical two-tailed graft reconstruction of the PLC in the setting of multiligament knee injuries (MKLIs) with grade III varus instability. Patients were identified through a prospective MLKI database between 2004 and 2013. Patients who received fibular collateral ligament and PLC reconstructions using a two-tailed graft and had a minimum follow-up of 2 years were included. Patients were assessed for clinical laxity grade, range of motion, and functional outcomes using Lysholm and International Knee Documentation Committee (IKDC) scores. Twenty patients (16 male, 4 female) with a mean age of 30.7 (range: 16-52) and a mean follow-up of 52.2 months (range: 24-93 months) were included. Knee dislocation (KD) grades included: 4 KD-1, 10 KD 3-L, 5 KD-4, and 1 KD-5. No patients had isolated PLC injuries. Mean IKDC and Lysholm score were 73.1 ± 25.8 and 78 ± 26, respectively. Mean range of motion was -1.1 to 122.8. In full extension, two patients (10%) had grade 1 laxity to varus stress. In 30 degrees of knee flexion, five (25%) patients had grade 1 laxity, and two (10%) had grade 2 laxity. Anatomical two-tailed PLC reconstruction can reliably restore varus stability when performed on patients with MLKIs and type C posterolateral instability with hyperextension external rotation recurvatum deformity. Satisfactory functional outcome scores were achieved in the majority of patients. This study supports the use of an anatomical two-tailed PLC reconstruction in the multiligament injured knee. The level of evidence is IV, case series. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Impact of top end anastomosis design on patency and flow stability in coronary artery bypass grafting.

    Science.gov (United States)

    Koyama, Sachi; Kitamura, Tadashi; Itatani, Keiichi; Yamamoto, Tadashi; Miyazaki, Shohei; Oka, Norihiko; Nakashima, Kouki; Horai, Tetsuya; Ono, Minoru; Miyaji, Kagami

    2016-05-01

    For coronary artery bypass grafting (CABG), free grafts such as a saphenous vein or radial artery are often used for grafts to the lateral and posterior walls. However, the relationship between top-end anastomosis design and long-term patency remains unknown. Because coronary artery blood flow is dominant during diastole, top-end anastomosis may work better if the graft is directed towards the apex, whereas the shortest graft pathway appears to be most efficient. Using computational fluid dynamic models, we evaluated the hemodynamic variables that were affected by the angle of the top-end anastomosis. We created three-dimensional geometries of the aortic root with coronary arteries that involved 75 % stenosis in the obtuse marginal and postero-lateral branches. Two bypass models under vasodilator administration were created: in a"Model A", the top-end anastomosis is parallel to the long axis of the ascending aorta and the graft passed over the conus directed towards the apex; in a "Model B", the top-end anastomosis is directed toward the shortest pathway, and form near the right angles to the long axis of the ascending aorta. Wall shear stress (WSS) and its fluctuation, an oscillatory shear index (OSI) were evaluated to predict fibrosis progression at the anastomosis site and graft flow. Graft flow was 197.3 ml/min and 207.3 ml/min in the "Model A" and "Model B", respectively. The minimal WSS value inside the graft with the "Model A" and "Model B" was 0.53 Pa and 4.09 Pa, respectively, and the OSI value was 0.46 and 0.04, respectively. The top-end anastomosis of a free graft should be directed vertically towards the aorta to achieve the shortest graft pathway to maintain a high graft flow rate and to avoid the risks of endothelial fibrosis and plaque progression over the long-term after CABG.

  10. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  11. Local full-thickness skin graft of the donor arm--a novel technique for the reduction of donor site morbidity in radial forearm free flap.

    Science.gov (United States)

    Riecke, B; Assaf, A T; Heiland, M; Al-Dam, A; Gröbe, A; Blessmann, M; Wikner, J

    2015-08-01

    A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Preparation of poly(ether ether ketone)-based polymer electrolytes for fuel cell membranes using grafting technique

    International Nuclear Information System (INIS)

    Hasegawa, Shin; Suzuki, Yasuyuki; Maekawa, Yasunari

    2008-01-01

    Poly(ether ether ketone) (PEEK)-based polymer electrolyte membranes (PEMs) was successfully prepared by radiation grafting of a styrene monomer into PEEK films and the consequent selective sulfonation of the grafting chains in the film state. Using milder sulfonation, the sulfonation reactions proceeded at the grafted chains in preference to the phenylene rings of PEEK main chains; as a result, the grafted films could successfully transform to a PEM with conductivity of more than 0.1 S/cm. The ion exchange capacity (IEC) and conductivity of the grafted PEEK electrolyte membranes were controlled to the ranges of 1.2-2.9 mmol/g and 0.03-0.18 S/cm by changing the grafting degree. It should be noted that this is the first example of directly transforming super-engineering plastic films into a PEM using radiation grafting

  13. The impact of hemoglobin levels on patient and graft survival in renal transplant recipients.

    LENUS (Irish Health Repository)

    Moore, Jason

    2008-08-27

    It remains unclear whether low hemoglobin levels are associated with increased mortality or graft loss after renal transplantation. This study assessed the relationship of hemoglobin levels with patient and graft survival in 3859 patients with functioning renal transplants more than 6-months posttransplantation.

  14. Impact of age, gender and race on patient and graft survival ...

    African Journals Online (AJOL)

    age, race and gender, on the outcome of renal transplantation. Most reports ... Gender does not influence graft survival, but females do have a higher overall mortality rate following renal transplantation at our centre. S Afr Med 2003; 93: 689-695. have a suitable living ..... analysis of its role in graft outcome. Transplantation ...

  15. Styrene grafted natural rubber reinforced by in situ silica generated via sol–gel technique

    Energy Technology Data Exchange (ETDEWEB)

    Sittiphan, Torpong [Program of Petrochemistry and Polymer Sciences, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Prasassarakich, Pattarapan [Department of Chemical Technology, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Poompradub, Sirilux, E-mail: sirilux.p@chula.ac.th [Department of Chemical Technology, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand)

    2014-02-15

    Highlights: • Sol–gel reaction by NR latex was the absence of use of organic solvent and base catalyst. • Well dispersed in situ formed silica particles in the rubber matrix were obtained. • In situ silica was better to improve mechanical properties of rubber vulcanizates. -- Abstract: The filling of styrene graft natural rubber (ST-GNR) with in situ formed silica was performed using the sol–gel reaction via the latex solution method. The mechanical properties of ST-GNR/NR vulcanizate were improved when using the in situ formed silica to levels higher than those obtained with the commercial ex situ formed silica filled ST-GNR/NR vulcanizates at a comparable silica content of 12 parts by weight per hundred parts of rubber. Transmission electron microscopy analysis revealed that the in situ silica particles were small (∼40 nm diameter) and well dispersed, while the commercial silica particles were larger (∼60 nm diameter) and markedly agglomerated in the rubbery matrix. The mechanical properties of the composites prepared via both the solid rubber and latex solution methods were comparable.

  16. High proximal migration in cemented acetabular revisions operated with bone impaction grafting; 47 revision cups followed with RSA for 17 years.

    Science.gov (United States)

    Mohaddes, Maziar; Herberts, Peter; Malchau, Henrik; Johanson, Per-Erik; Kärrholm, Johan

    2017-05-12

    Bone impaction grafting is a biologically and mechanically appealing option in acetabular revision surgery, allowing restitution of the bone stock and restoration of the biomechanics. We analysed differences in proximal migration of the revision acetabular components when bone impaction grafting is used together with a cemented or an uncemented cup. 43 patients (47 hips), revised due to acetabular loosening and judged to have less than 50% host bone-implant contact were included. The hips were randomised to either an uncemented (n = 20) or a cemented (n = 27) revision cup. Radiostereometry and radiography was performed postoperatively, at 3 and 6 months, 1, 2, 3, 5, 7, 10 and 13 and 17 years postoperatively. Clinical follow-up was performed at 1, 2 and 5 years postoperatively and thereafter at the same interval as in the radiographic follow-up. There were no differences in the base line demographic data between the 2 groups. At the last follow-up (17 years) 14 hips (10 cemented, 4 uncemented) had been re-revised due to loosening. 3 additional cups (1 uncemented and 2 cemented) were radiographically loose. There was a higher early proximal migration in the cemented cups. Cups operated on with cement showed a higher early migration measured with RSA and also a higher number of late revisions. The reason for this is not known, but factors such as inclusion of cases with severe bone defects, use of smaller bone chips and issues related to the impaction technique might have had various degrees of influence.

  17. A Novel Surgical Technique for Fixation of Recurrent Acromioclavicular Dislocations: AC Dog Bone Technique in Combination with Autogenous Semitendinosus Tendon Graft

    Directory of Open Access Journals (Sweden)

    Patrick Holweg

    2017-01-01

    Full Text Available Various surgical techniques have been described for the fixation of acromioclavicular (AC dislocations. However, recurrent dislocation is one of the main complications associated with the majority of these techniques. We report a case of postoperative AC joint redislocation. In order to overcome recurrent dislocation after revision surgery, a reconstruction of the conoid and trapezoid ligament with the use of a free tendon graft in combination with a FiberTape was provided within a novel surgical technique. After 12 months, the patient was very satisfied with the functional outcome. The patient achieved excellent results in the Constant (98 points, SPADI (0 points, and QuickDASH score (0 points. The described technique results in an anatomic reconstruction of the AC joint. The nonrigid nature of the intervention seems to restore the normal arthrokinematics by reconstructing the coracoclavicular ligaments with an autograft which is then protected by the AC Dog Bone artificial ligaments during the healing period. The arthroscopic approach to the AC joint with minimal exposure reduces the risks and complications of the intervention. This is the first case in literature that utilizes the artificial dog bone ligament securing the autograft in an anatomic AC reconstruction.

  18. Assisted eruption of impacted teeth into an alveolar bone graft in a patient with cleft lip and palate.

    Science.gov (United States)

    Peamkaroonrath, Chonthicha; Manosudprasit, Montien; Godfrey, Keith

    2008-11-01

    To assist the eruption of impacted upper teeth into an alveolar bone graft in a patient with a unilateral cleft lip and palate. An 8-year-old Thai boy with left unilateral complete cleft lip and palate had the chief complaint of anterior crossbite. He presented with a mild skeletal 3, dental Class III subdivision malocclusion, anterior crossbite, left unilateral posterior crossbite, moderate crowding in the upper arch with impaction of upper the left lateral incisor (tooth 22) and canine (tooth 23). In the first phase of treatment the posterior crossbite was corrected with a removable appliance with a 3-way screw. In the second phase the impacted teeth were surgically exposed, moved into the alveolar bone graft and the teeth aligned with fixed appliances. The upper left lateral incisor was extracted because of its questionable longevity. The orthodontic treatment resulted in normal overjet, overbite and an acceptable facial profile. A prosthesis replaced tooth 22. Forced eruption of impacted teeth can be carried out successfully in the cleft patients after an appropriate treatment plan has been formulated and following preparation of alveolar bone graft in the cleft site.

  19. Techniques for inventorying manmade impacts in roadway environments.

    Science.gov (United States)

    Dale R. Potter; J. Alan. Wagar

    1971-01-01

    Four techniques for inventorying manmade impacts along roadway corridors were devised and compared. Ground surveillance and ground photography techniques recorded impacts within the corridor visible from the road. Techniques on large- and small-scale aerial photography recorded impacts within a more complete corridor that included areas screened from the road by...

  20. Electrocardiographic Changes in Certain Cardiovascular Physiological and Pathological Settings. Impact on Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Dimitar Simov

    2016-03-01

    Full Text Available Review on electrocardiographic changes provoked by aging, diagnostic tests, cardiac surgery, hemodialysis, diabetes, etc., is the objective of the current material. Several electrocardiographic (ECG parameters that are well known risk markers of arrhythmias, incidental heart failure and sudden cardiac death (SCD are discussed: QRS amplitude, QRS morphology, QRS duration, QRS alternans, T-wave amplitude, T-wave morphology, T-wave alternans, negative T-waves, 3D-spatial angle between maximal QRS and T vectors of the vectorcardiographic loops, ST-segment elevation, QT-interval dispersion, and heart rate. All reviewed parameters are compared with the results on the ECG-alterations, induced by coronary artery bypass grafting (CABG surgery. Two parameters showed an improvement in the patients' condition: QRS-T angle and cardiac autonomic innervation while two others (T-wave alternans and heart rate indicated deterioration. We tend to assume that the deterioration in this early post-operative period is an effect of the post-surgery trauma. We speculate that this effect will fade away in a period of a month and more after surgery, and we intend to conduct such a research in the future. The analysis of ECG's changes will help to better assess the impact of the CABG surgery.

  1. Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison.

    Science.gov (United States)

    Vaillant, Eric R; Parks, Brent G; Camire, Lyn M; Hinton, Richard Y

    2017-11-01

    The aim of this article is to compare diameter and stiffness, displacement, and strain in a five-strand versus four-strand hamstring graft for anterior cruciate ligament reconstruction. Eight matched pairs of lower extremities underwent four-strand or five-strand hamstring graft reconstruction. Diameter was significantly higher in the five-strand versus the four-strand construct ( p  = 0.002). No significant difference was found between the groups in construct displacement or stiffness. Significantly higher strain was observed in the inner limb versus the outer limb in the four-strand construct ( p  = 0.001) and in the inner limb versus the fifth limb in the 5-strand construct ( p  = 0.004). A fifth limb added to a four-strand hamstring graft significantly increased graft diameter but did not significantly change stiffness or displacement, suggesting that attachment of additional graft material via suture did not provide for full incorporation of the added limb into the graft at time zero. The inner limb in both constructs absorbed significantly greater load than did other limbs. The use of suture to attach additional material to a four-strand hamstring graft may not contribute to improved biomechanical qualities of the graft at time zero. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Management of chest deformity caused by microtia reconstruction: Comparison of autogenous diced cartilage versus cadaver cartilage graft partial filling techniques.

    Science.gov (United States)

    Go, Ju Young; Kang, Bo Young; Hwang, Jin Hee; Oh, Kap Sung

    2017-01-01

    Efforts to prevent chest wall deformity after costal cartilage graft are ongoing. In this study, we introduce a new method to prevent donor site deformation using irradiated cadaver cartilage (ICC) and compare this method to the autogenous diced cartilage (ADC) technique. Forty-two pediatric patients comprised the ADC group (n = 24) and the ICC group (n = 18). After harvesting costal cartilage, the empty perichondrial space was filled with autologous diced cartilage in the ADC group and cadaver cartilage in the ICC group. Digital photographs and rib cartilage three-dimensional computed tomography (CT) data were analyzed to compare the preventive effect of donor site deformity. We compared the pre- and postoperative costal cartilage volumes using 3D-CT and graded the volumes (grade I: 0%-25%, grade II: 25%-50%, grade III: 50%-75%, and grade IV: 75%-100%). The average follow-up period was 20 and 24 months in the ADC and ICC groups, respectively. Grade IV maintenance of previous costal cartilage volume was evident postoperatively in 22% of patients in the ADC group and 82% of patients in the ICC group. Intercostal space narrowing and chest wall depression were less in the ICC group. There were no complications or severe resorption of cadaver cartilage. ICC support transected costal ring and prevented stability loss by acting as a spacer. The ICC technique is more effective in preventing intercostal space narrowing and chest wall depression than the ADC technique. Samsung Medical Center Institution Review Board, Unique protocol ID: 2009-10-006-008. This study is also registered on PRS (ClinicalTrials.gov Record 2009-10-006). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Impact of graft-versus-host disease after reduced-intensity conditioning allogeneic stem cell transplantation for acute myeloid leukemia

    DEFF Research Database (Denmark)

    Baron, F; Labopin, M; Niederwieser, D

    2012-01-01

    This report investigated the impact of graft-versus-host disease (GVHD) on transplantation outcomes in 1859 acute myeloid leukemia patients given allogeneic peripheral blood stem cells after reduced-intensity conditioning (RIC allo-SCT). Grade I acute GVHD was associated with a lower risk...... of relapse (hazards ratio (HR)=0.7, P=0.02) translating into a trend for better overall survival (OS; HR=1.3; P=0.07). Grade II acute GVHD had no net impact on OS, while grade III-IV acute GVHD was associated with a worse OS (HR=0.4, P...

  4. One-stage reconstruction of soft tissue defects with the sandwich technique: Collagen-elastin dermal template and skin grafts

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2011-01-01

    Full Text Available Background : A full-thickness soft tissue defect closure often needs complex procedures. The use of dermal templates can be helpful in improving the outcome. Objective : The objective was to evaluate a sandwich technique combining the dermal collagen-elastin matrix with skin grafts in a one-stage procedure. Materials and Methods : Twenty-three patients with 27 wounds were enrolled in this prospective single-centre observational study. The mean age was 74.8 ± 17.2 years. Included were full-thickness defects with exposed bone, cartilage and/ or tendons. The dermal collagen-elastin matrix was applied onto the wound bed accomplished by skin transplants, i.e. ′sandwich′ transplantation. In six wounds, the transplants were treated with intermittent negative pressure therapy. Results : The size of defects was ≤875 cm 2 . The use of the dermal template resulted in a complete and stable granulation in 100% of wounds. Seventeen defects showed a complete closure and 19 achieved a complete granulation with an incomplete closure. There was a marked pain relief. No adverse events were noted due to the dermal template usage. Conclusions : Sandwich transplantation with the collagen-elastin matrix is a useful tool when dealing with full-thickness soft tissue defects with exposed bone, cartilage or tendons.

  5. Relevant insight of surface characterization techniques to study covalent grafting of a biopolymer to titanium implant and its acidic resistance

    Science.gov (United States)

    D'Almeida, Mélanie; Amalric, Julien; Brunon, Céline; Grosgogeat, Brigitte; Toury, Bérangère

    2015-02-01

    Peri-implant bacterial infections are the main cause of complications in dentistry. Our group has previously proposed the attachment of chitosan on titanium implants via a covalent bond to improve its antibacterial properties while maintaining its biocompatibility. A better knowledge of the coating preparation process allows a better understanding of the bioactive coating in biological conditions. In this work, several relevant characterization techniques were used to assess an implant device during its production phase and its resistance in natural media at different pH. The titanium surface was functionalized with 3-aminopropyltriethoxysilane (APTES) followed by grafting of an organic coupling agent; succinic anhydride, able to form two covalent links, with the substrate through a Ti-O-Si bond and the biopolymer through a peptide bond. Each step of the coating synthesis as well as the presence confirmation of the biopolymer on titanium after saliva immersion was followed by FTIR-ATR, SEM, EDS, 3D profilometry, XPS and ToF-SIMS analyses. Results allowed to highlight the efficiency of each step of the process, and to propose a mechanism occurring during the chitosan coating degradation in saliva media at pH 5 and at pH 3.

  6. Production and installation of equipments for radiation-induced graft polymerization in liquid phase and dipping techniques

    International Nuclear Information System (INIS)

    Seko, Noriaki; Kasai, Noboru; Tamada, Masao; Hasegawa, Shin; Katakai, Akio; Sugo, Takanobu

    2005-01-01

    Fibrous adsorbent which is synthesized by radiation induced graft polymerization on the trunk polymers such as polymer nonwoven fabrics and woven cloths exhibits an excellent selective adsorption against heavy metal ions and toxic gases at extremely low concentrations. Two equipments were installed to synthesize the metal-ion and gas adsorbents by means of the radiation-induced graft polymerization in the liquid phase and the dipping, respectively. In the reation chamber of the liquid phase reactor, the oxygen decreased to 100 ppm. The inside temperature was elevated at 80C. These characteristics satisfied the specification. The fabric transport can regulate the rate in the range from 1 to 10 m/min. The reactor for the dip grafting could reduce the inside oxygen to 100ppm and inside temperature could reach to 80C, also. The transport system is stable during the dip grafting reaction. The grafting of glycidyl methacrylate was carried out as a characteristic test. The degree of grafting was controlled in the range of 40-70%. The both equipments can graft the trunk polymer, 2000mm in maximum width and 1m in maximum diameter. This size is enough for confirmation practical scale synthesis. (author)

  7. One stage revision single-bundle anterior cruciate ligament reconstruction with impacted morselized bone graft following a failed double-bundle reconstruction

    Directory of Open Access Journals (Sweden)

    Ho Jong Ra

    2017-01-01

    Full Text Available Although double-bundle anterior cruciate ligament (ACL reconstruction has theoretical benefits such as more accurate reproduction of ACL anatomy, it is technically more demanding surgery. This report describes the case of a one stage revision single-bundle ACL reconstruction after primary double-bundle ACL reconstruction. A professional dancer had an ACL previously reconstructed with a double-bundle technique, but the femoral tunnels were malpositioned resulting in residual laxity and rotational instability. The previous femoral tunnel positions were vertical and widened. The previous vertical tunnels were filled with impacted bone graft and a revision single-bundle ACL reconstruction was performed via the new femoral tunnel with a 2 O'clock position between the previous two tunnels. After 10 months of postoperative rehabilitation, the patient returned to professional dancing with sound bony union and without any residual instability.

  8. Impact of statins and beta-blocker therapy on mortality after coronary artery bypass graft surgery

    Science.gov (United States)

    Blackstone, Eugene; Kapadia, Samir R.

    2015-01-01

    Background We conducted a retrospective cohort study of patients after first-time isolated coronary artery bypass graft surgery (CABG) and assessed the impact of a discharge regimen including beta-blockers and statin therapy and their relationship to long-term all cause mortality and major adverse cardiovascular events (MACE). Methods We identified patients age >18 years, undergoing first time isolated CABG from 1993 to 2005. Patients were identified using the Cardiovascular Information Registry (CVIR). We collected follow-up information at 30, 60, 90 days and yearly follow-up. The registry is approved for use in research by the institutional review broad. Results We identified 5,205 patients who underwent single isolated CABG between January 1993 and December 2005. The mean age was 64.5±9.7 years and over 70% were male. There was a significant difference in the low density lipoproteins (LDL) concentration between those with or without statin medications (134±41.9 mg/dL) (no statin) vs. 126±44.8 mg/dL (with statin), P=0.001. A discharge regimen with statin therapy was associated with and overall reduction in 30 day, 1 year and long-term mortality. In addition, overall the triple ischemic endpoint of death, myocardial infarction (MI) and stroke was also significantly lower in the statin vs. no-statin group. In addition, statin and beta-blockers exerted synergistic effect on overall mortality outcomes short-term and in the long-term. We note that the predictors of overall death include no therapy with statin therapy and age [hazard ratios (HR) 1.1, 95% CI: 1.04-1.078, P<0.001] and presence of renal failure (HR 2.0, P=0.005). The estimated 11-year Kaplan Meier curves for mortality between the two groups starts to diverge immediately post discharge after single isolated CABG and continue to diverge through out the follow-up period. Conclusions A post-discharge regimen of statins independently reduces overall and 1 year mortality. These results confirm those of

  9. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    .1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19 but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p  Conclusion We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.

  10. Impact on early and late mortality after blood transfusion in coronary artery bypass graft surgery.

    Science.gov (United States)

    Santos, Antonio Alceu dos; Sousa, Alexandre Gonçalves; Thomé, Hugo Oliveira de Souza; Machado, Roberta Longo; Piotto, Raquel Ferrari

    2013-03-01

    To assess the 30-day and 1-year mortality associated to the red blood cell transfusion after coronary artery bypass grafting surgery. This procedure has been questioned by the international medical community, but it is still widely used in cardiac surgery. Therefore, it is needed more evidence of this medical practice in our country. We retrospectively analyzed 3,004 patients who underwent coronary artery bypass grafting surgery between June 2009 and July 2010. Patients were divided into two groups: non-transfused and transfused. The transfused group totaled 1,888 (63%) and non-transfused 1,116 (37%). There were 129 deaths in 30 days, with 108 (84%) in the transfused group and 21 (16%) in the non-transfused (Pconservation strategies should be encouraged to reduce blood products transfusions.

  11. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by /sup 133/Xe clearance technique

    Energy Technology Data Exchange (ETDEWEB)

    Basa, S; Ercan, M T; Aras, T; Araz, K

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of /sup 133/Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), /sup 133/Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2+-12.9 and 58.3+-3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4+-3.2 and 21.7+-15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2+-16.9 ml/100 g/min) and above (63.9+-9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing.

  12. Satisfactory knee function after single-stage posterolateral corner reconstruction in the multi-ligament injured/dislocated knee using the anatomic single-graft technique.

    Science.gov (United States)

    Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A

    2018-04-01

    Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence

  13. Impact of Intensive Physiotherapy on Cognitive Function after Coronary Artery Bypass Graft Surgery.

    Science.gov (United States)

    Cavalcante, Elder Dos Santos; Magario, Rosmeiri; Conforti, César Augusto; Cipriano Júnior, Gerson; Arena, Ross; Carvalho, Antonio Carlos C; Buffolo, Enio; Luna Filho, Bráulio

    2014-11-01

    Background: Coronary artery bypass graft (CABG) is a standard surgical option for patients with diffuse and significant arterial plaque. This procedure, however, is not free of postoperative complications, especially pulmonary and cognitive disorders. Objective: This study aimed at comparing the impact of two different physiotherapy treatment approaches on pulmonary and cognitive function of patients undergoing CABG. Methods: Neuropsychological and pulmonary function tests were applied, prior to and following CABG, to 39 patients randomized into two groups as follows: Group 1 (control) - 20 patients underwent one physiotherapy session daily; and Group 2 (intensive physiotherapy) - 19 patients underwent three physiotherapy sessions daily during the recovery phase at the hospital. Non-paired and paired Student t tests were used to compare continuous variables. Variables without normal distribution were compared between groups by using Mann-Whitney test, and, within the same group at different times, by using Wilcoxon test. The chi-square test assessed differences of categorical variables. Statistical tests with a p value ≤ 0.05 were considered significant. Results: Changes in pulmonary function were not significantly different between the groups. However, while Group 2 patients showed no decline in their neurocognitive function, Group 1 patients showed a decline in their cognitive functions (P ≤ 0.01). Conclusion: Those results highlight the importance of physiotherapy after CABG and support the implementation of multiple sessions per day, providing patients with better psychosocial conditions and less morbidity.Fundamento: A cirurgia de revascularização miocárdica (CRM) é a opção cirúrgica padrão para pacientes com placas arteriais difusas e significativas. Tal procedimento, no entanto, não é desprovido de complicações pós-operatórias, especialmente distúrbios pulmonares e cognitivos. Objetivo: Comparar o impacto de duas abordagens fisioterap

  14. Percutaneous intramedullary decompression, curettage, and grafting with medical-grade calcium sulfate pellets for unicameral bone cysts in children: a new minimally invasive technique.

    Science.gov (United States)

    Dormans, John P; Sankar, Wudbhav N; Moroz, Leslie; Erol, Bülent

    2005-01-01

    Several treatment options exist for unicameral bone cysts (UBCs), including observation, steroid injection, bone marrow injection, and curettage and bone grafting. These are all associated with high recurrence rates, persistence, and occasional complications. Newer techniques have been described, most with variable success and only short follow-up reported. Because of these factors, a new minimally invasive percutaneous technique was developed for the treatment of UBCs in children. Twenty-eight children with UBCs who underwent percutaneous intramedullary decompression, curettage, and grafting with medical-grade calcium sulfate (MGCS) pellets by the senior author (J.P.D.) between April 2000 and April 2003 were analyzed as part of a pediatric musculoskeletal tumor registry at a large tertiary children's hospital. Four patients were lost to follow-up, and the remaining 24 patients had an average follow-up of 21.9 months (range 4-48 months). Twelve patients were followed for at least 24 months. Six of the 24 children had received previous treatment of their UBC, most often at an outside institution. Follow-up was performed through clinical evaluation and radiographic review. Postoperative radiographs at most recent follow-up showed complete healing, defined as more than 95% opacification, in 22 of 24 patients (91.7%). One patient (4.2%) demonstrated partial healing, defined as 80% to 95% opacification. One patient had less than 80% radiographic healing (4.2%). All 24 patients returned to full activities and were asymptomatic at most recent follow-up. The only complication noted was a superficial suture abscess that occurred in one patient; this resolved with local treatment measures. The new minimally invasive technique of percutaneous intramedullary decompression, curettage, and grafting with MGCS pellets demonstrates favorable results with low complication and recurrence rates compared with conventional techniques. The role of intramedullary decompression as a part

  15. IMPACT OF PREOPERATIVE METOPROLOL ON THE OCCURRENCE OF NEW-ONSET ATRIAL FIBRILLATION AFTER CORONARY ARTERY BYPASS GRAFTING

    Directory of Open Access Journals (Sweden)

    Salla Surya Prakasarao

    2016-09-01

    less than the western population. Advanced age and Left ventricular dysfunction increases the risk. The technique of the surgery is not found to be affecting. Postoperative AF remains common with an incidence of 6.14%. The study has shown that preoperative therapy with Metoprolol continuing through the postoperative period significantly reduces the incidence of new-onset postoperative Atrial fibrillation in coronary artery disease patients undergoing coronary bypass grafting.

  16. The Impact of Total Ischemic Time, Donor Age and the Pathway of Donor Death on Graft Outcomes After Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Wong, Germaine; Teixeira-Pinto, Armando; Chapman, Jeremy R; Craig, Jonathan C; Pleass, Henry; McDonald, Stephen; Lim, Wai H

    2017-06-01

    Prolonged ischemia is a known risk factor for delayed graft function (DGF) and its interaction with donor characteristics, the pathways of donor death, and graft outcomes may have important implications for allocation policies. Using data from the Australian and New Zealand Dialysis and Transplant registry (1994-2013), we examined the relationship between total ischemic time with graft outcomes among recipients who received their first deceased donor kidney transplants. Total ischemic time (in hours) was defined as the time of the donor renal artery interruption or aortic clamp, until the time of release of the clamp on the renal artery in the recipient. A total of 7542 recipients were followed up over a median follow-up time of 5.3 years (interquartile range of 8.2 years). Of these, 1823 (24.6%) experienced DGF and 2553 (33.9%) experienced allograft loss. Recipients with total ischemic time of 14 hours or longer experienced an increased odd of DGF compared with those with total ischemic time less than 14 hours. This effect was most marked among those with older donors (P value for interaction = 0.01). There was a significant interaction between total ischemic time, donor age, and graft loss (P value for interaction = 0.03). There was on average, a 9% increase in the overall risk of graft loss per hour increase in the total ischemic time (adjusted hazard ratio, 1.09; 95% confidence interval, 1.01-1.18; P = 0.02) in recipients with older donation after circulatory death grafts. There is a clinically important interaction between donor age, the pathway of donor death, and total ischemic time on graft outcomes, such that the duration of ischemic time has the greatest impact on graft survival in recipients with older donation after circulatory death kidneys.

  17. Propagação de Jabuticabeira por enxertia e alporquia Propagation of jabuticaba tree for grafting and air layering techniques

    Directory of Open Access Journals (Sweden)

    Simone Aparecida Zolet Sasso

    2010-06-01

    Full Text Available O objetivo deste trabalho foi investigar a eficiência das técnicas de enxertia e alporquia na produção de mudas de jabuticabeira. Testou-se a pega de enxertia de três espécies de jabuticabeira (Plinia cauliflora, P. trunciflora, P. jaboticaba sobre porta-enxertos de P. cauliflora, em duas épocas (maio e agosto. Avaliaram-se a brotação e o número e tamanho de brotos, após 90 dias da implantação do experimento. Para alporquia, foram testados dois diâmetros de ramos (1,0-1,5 cm e 2,0-2,5 cm e duas larguras do anelamento (1,5 cm e 3,0 cm, na espécie P. cauliflora. Avaliaram-se o enraizamento e o número e tamanho de raízes, após 180 dias da implantação do experimento. A enxertia e a alporquia são técnicas recomendáveis para a propagação da jabuticabeira, pois proporcionam alto percentual de formação de mudas, de até 72,9% e 87,5%, respectivamente. Houve pega de enxertia das três espécies enxertadas sobre P. cauliflora. A utilização de garfos retirados de plantas em frutificação deve ser evitada, pois ocorre inibição da brotação dos enxertos. Na alporquia, ramos de diâmetro de 2,0-2,5 cm proporcionam maior enraizamento e maior número e tamanho de raízes, em relação a ramos de menor diâmetro (1,0 a 1,5 cm.The objective of this work was to test the efficiency of grafting and air layering propagation techniques for jabuticaba tree. Was tested compatibility of grafting of three species of jabuticaba tree (Plinia cauliflora, P. trunciflora and P. jaboticaba on rootstocks of P. cauliflora, and two periods (May and August. The percentage of grafting, number and size of shoots, was evaluated 90 days after the experiment started. Air layering was made in P. cauliflora using two diameters of branches (1.0-1.5 cm and 2.0-2.5 cm and two widths of girdling (1.5 cm and 3.0 cm. It was evaluated the rooting percentage, number and length of roots, 180 days after the experiment started. Both grafting and the air layering are

  18. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  19. Comparison of a new hydro-surgical technique to traditional methods for the preparation of full-thickness skin grafts from canine cadaveric skin and report of a single clinical case.

    Science.gov (United States)

    Townsend, F I; Ralphs, S C; Coronado, G; Sweet, D C; Ward, J; Bloch, C P

    2012-01-01

    To compare the hydro-surgical technique to traditional techniques for removal of subcutaneous tissue in the preparation of full-thickness skin grafts. Ex vivo experimental study and a single clinical case report. Four canine cadavers and a single clinical case. Four sections of skin were harvested from the lateral flank of recently euthanatized dogs. Traditional preparation methods used included both a blade or scissors technique, each of which were compared to the hydro-surgical technique individually. Preparation methods were compared based on length of time for removal of the subcutaneous tissue from the graft, histologic grading, and measurable thickness as compared to an untreated sample. The hydro-surgical technique had the shortest skin graft preparation time as compared to traditional techniques (p = 0.002). There was no significant difference in the histological grading or measurable subcutaneous thickness between skin specimens. The hydro-surgical technique provides a rapid, effective debridement of subcutaneous tissue in the preparation of full-thickness skin grafts. There were not any significant changes in histological grade and subcutaneous tissue remaining among all treatment types. Additionally the hydro-surgical technique was successfully used to prepare a full-thickness meshed free skin graft in the reconstruction of a traumatic medial tarsal wound in a dog.

  20. Improving the cell affinity of a poly(D,L-lactide) film modified by grafting collagen via a plasma technique

    International Nuclear Information System (INIS)

    Zhao Jianhao; Wang Jue; Tu Mei; Luo Binghong; Zhou Changren

    2006-01-01

    Poly(D,L-lactide) films were surface-modified by grafting collagen via NH 3 plasma to improve cell affinity. The modified films were characterized by IR analysis, contact angle measurement, SEM analysis and collagen quantity determination. It was demonstrated that -NH 2 and collagen were incorporated into the surface of PDLLA films. The hydrophilicity of the PDLLA film increased after NH 3 plasma treatment, but decreased with further collagen modification. More collagen was incorporated into the PDLLA films by a grating method as compared to that with an anchorage treatment. L929 fibroblast cells were used to evaluate the cell affinity of the modified films and control. It was shown that PDLLA films surface-modified by grafting collagen via NH 3 plasma more efficiently enhanced the cells attachment and proliferation than those films modified by collagen anchorage or only NH 3 plasma treatment

  1. Anatomic study of juxta renal aneurysms: impact on fenestrated stent-grafts.

    Science.gov (United States)

    Azzaoui, Richard; Sobocinski, Jonathan; Maurel, Blandine; D'Elia, Piervito; Perrot, Céline; Bianchini, Aurélia; Guillou, Matthieu; Haulon, Stéphan

    2011-04-01

    Fenestrated stent-grafts allow for treatment of patients with juxtarenal aneurysms (JRA) when they present with contraindications for conventional treatment. The fenestrated module is a custom-made module, specially designed to fit a specific patient, using computed tomographic scan measurements, which entails manufacturing delay and high cost. The aim of our study was to evaluate the possibility to reproduce the interrenal aorta anatomy to design a standard fenestrated module that would fit the maximum number of patients with JRA. On a three-dimensional working station, we analyzed 289 preoperative computed tomographic scan results of patients with JRA and who were treated with fenestrated stent-grafts comprising two fenestrations for the renal arteries and a scallop for the superior mesenteric artery (SMA). On curvilinear reconstructions, we successively measured the interrenal aorta diameter, its orientation, as well as the height of each renal ostium, taking the ostium center of the SMA as a reference mark. Later, a statistical analysis of these measures distribution was performed so as to design a fenestrated module that would fit the maximum number of patients. The center of the left renal artery presented with a median orientation of 82.5° (range, 37.5-150) and a median distance of 9 mm (range, 0-30), in relation to the SMA ostium. The ostium center of the right renal artery presented with a median orientation of 285° (range, 240-337.5) and a median distance of 8 mm (range, 3-30), in relation to the SMA ostium. By positioning the current renal fenestrations (6-mm wide), on the basis of the calculated median positions, in our series, only 20% of the patients could be treated with a standard fenestrated module. Should the diameter of these fenestrations be increased by 10 mm, it would then be possible to treat 50% of our patients. The anatomy of the interrenal aorta and its branches is quite reproducible to design standard fenestrated stent-grafts that could

  2. The Impact of Anastomotic Angle for Re-Occlusion of Brachioaxillary Graft Arteriovenous Fistula after Percutaneous Thromboaspiration

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keon Young; Jin, Gong Yong; Hwang, Seung Bae; Choi, Eun Jung; Song, Ji Soo; Han, Young Min; Kwon, Keun Sang [Chonbuk National University Hospital and Medical School, Jeonju (Korea, Republic of)

    2013-03-15

    The purpose of this study is to evaluate the factors that affect graft patency in brachioaxillary graft arteriovenous fistula patients. A retrospective study was conducted on 33 patients (20 men, 13 women; mean age, 67.5 years; mean interval to first stenosis, 17 months), who had performed percutaneous angioplasty for first episode of stenosis after brachioaxillary graft surgery. We evaluated the relevant factors affecting the graft patency after first episode of stenosis, such as age, sex, underlying disease (hypertension, diabetes mellitus, hyperlipidemia, cardiovascular disease, cerebrovascular attack), anastomotic angle between graft and axillary vein, and anastomotic angle between the graft and brachial artery. Kaplan-Meier method and log rank test and receiver operating characteristics curve analysis were used in statistical analysis. Graft patency rates after 1 month, 6 months, and 12 months were 75.8%, 39.4%, and 9.1%. There was a correlation between graft-axillary vein anastomotic angle and patency rates (r = 0.372, p = 0.033); larger the venous anastomotic angle, the longer patency rate. However, it does not come up with significant results in patency rates on age, sex, underlying disease, and graft-brachial artery angle. In patients with brachioaxillary graft arteriovenous fistula, as venous anastomotic angle more obtuse, the graft patency may be longer.

  3. Hydrophilic/hydrophobic character of grafted cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E., E-mail: takacs@iki.kfki.h [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Wojnarovits, L. [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Borsa, J. [Budapest University of Technology and Economics (Hungary); Racz, I. [Bay Zoltan Institute for Materials Science and Technology, Budapest (Hungary)

    2010-04-15

    Vinyl monomers with long paraffin chains were grafted onto two kinds of cellulose (cotton and cotton linter) by direct irradiation grafting technique. The effect of dose, monomer structure and concentration, as well as homopolymer suppressor (styrene) concentration on the grafting yield was studied and the optimal grafting conditions were established. Grafting decreased the swelling of the samples in water and increased their polymer compatibility in polypropylene matrix.

  4. Fat Grafting for Facial Filling and Regeneration.

    Science.gov (United States)

    Coleman, Sydney R; Katzel, Evan B

    2015-07-01

    Plastic surgeons have come to realize that fat grafting can rejuvenate an aging face by restoring or creating fullness. However, fat grafting does much more than simply add volume. Grafted fat can transform or repair the tissues into which it is placed. Historically, surgeons have hesitated to embrace the rejuvenating potential of fat grafting because of poor graft take, fat necrosis, and inconsistent outcomes. This article describes fat grafting techniques and practices to assist readers in successful harvesting, processing, and placement of fat for optimal graft retention and facial esthetic outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  6. Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.

    Science.gov (United States)

    Shahverdyan, Robert; Mylonas, Spyridon; Gawenda, Michael; Brunkwall, Jan

    2018-04-01

    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients

  7. Can a Drill Guide Improve the Coracoid Graft Placement During the Latarjet Procedure? A Prospective Comparative Study With the Freehand Technique.

    Science.gov (United States)

    Barth, Johannes; Boutsiadis, Achilleas; Neyton, Lionel; Lafosse, Laurent; Walch, Gilles

    2017-10-01

    One of the factors that can affect the success of the Latarjet procedure is accurate coracoid graft (CG) placement. The use of a guide can improve placement of the CG and screw positioning in the sagittal and axial planes as compared with the classic open ("freehand") technique. Cohort study; Level of evidence, 2. A total of 49 patients who underwent a Latarjet procedure for the treatment of recurrent anterior shoulder instability were prospectively included; the procedure was performed with the freehand technique in 22 patients (group 1) and with use of a parallel drill guide during screw placement in 27 patients (group 2). All patients underwent a postoperative computed tomography scan with the same established protocol. The scans were used to evaluate and compare the position of the CG in the sagittal and axial planes, the direction of the screws (α angle), and overall contact of the graft with the anterior surface of the glenoid after the 2 surgical techniques. The CG was placed >60% below the native glenoid equator in 23 patients (85.2%) in group 2, compared with 14 patients (63.6%) in group 1 ( P = .004). In the axial plane, the position of the CG in group 2 patients was more accurate (85.2% and 88.9% flush) at the inferior and middle quartiles of the glenoid surface ( P = .012 and .009), respectively. Moreover, with the freehand technique (group 1), the graft was in a more lateral position in the inferior and middle quartiles ( P = .012 and .009, respectively). No differences were found between groups 1 and 2 regarding the mean α angle of the superior (9° ± 4.14° vs 11° ± 6.3°, P = .232) and inferior (9.5° ± 6° vs 10° ± 7.5°, P = .629) screws. However, the mean contact angle (angle between the posterior coracoid and the anterior glenoid surface) with the freehand technique (3.8° ± 6.8°) was better than that of the guide (8.55° ± 8°) ( P = .05). Compared with the classic freehand operative technique, the parallel drill guide can ensure

  8. Simplified non-cultured non-trypsinised epidermal cell graft technique followed by psoralen and ultraviolet a light therapy for stable vitiligo

    Directory of Open Access Journals (Sweden)

    Dilip Kachhawa

    2017-01-01

    Full Text Available Background and Aims: Stable vitiligo can be treated by various surgical procedures. Non-cultured melanocyte grafting techniques were developed to overcome the time-consuming process of culture while at the same time providing acceptable results. All the techniques using non-cultured melanocyte transfer involve trypsinisation as an integral step. Jodhpur technique used by the author is autologous, non-cultured, non-trypsinised, epidermal cell grafting. Settings and Design: The study was conducted on patients visiting the dermatology outpatient department of a tertiary health centre in Western Rajasthan. Materials and Methods: At the donor site, mupirocin ointment was applied and dermabrasion was done with the help of micromotor dermabrader till pinpoint bleeding was seen. The paste-like material obtained by this procedure containing melanocytes and keratinocytes admixed with the ointment base was harvested with spatula and was subsequently spread over the recipient area. Recipient site was prepared in the same manner by dermabrasion. After 10 days, dressing at both sites was removed taking utmost care at the recipient site as there was a theoretical risk of dislodging epidermal cells. Results: In a study of 437 vitiligo patches, more than 75% re-pigmentation (excellent improvement was seen in 41% of the patches. Lesions on thigh (100%, face (75% and trunk (50% showed maximal excellent improvement, whereas patches on joints and acral areas did not show much improvement. Conclusions: This technique is a simplified, cost effective, less time-consuming alternative to other techniques which involve tryspsinisation of melanocytes and at the same time provides satisfactory uniform pigmentation.

  9. Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System

    Directory of Open Access Journals (Sweden)

    Abdo Karim Tourkmani

    2017-03-01

    Full Text Available AIM: To analyze the relationship between the score obtained in the Risk Score System (RSS proposed by Hicks et al with penetrating keratoplasty (PKP graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS: The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases, incomplete medical notes (5 cases and follow-up less than 1y (3 cases. We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS: Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P0.05 between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05, although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION: After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.

  10. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery

    OpenAIRE

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro

    2017-01-01

    Background Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Methods Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery ...

  11. Evolution of skin grafting for treatment of burns: Reverdin pinch grafting to Tanner mesh grafting and beyond.

    Science.gov (United States)

    Singh, Mansher; Nuutila, Kristo; Collins, K C; Huang, Anne

    2017-09-01

    Skin grafting is the current standard care in the treatment of full thickness burns. It was first described around 1500 BC but the vast majority of advancements have been achieved over the past 200 years. An extensive literature review was conducted on Pubmed, Medline and Google Scholar researching the evolution of skin grafting techniques. The authors concentrated on the major landmarks of skin grafting and also provide an overview of ongoing research efforts in this field. The major innovations of skin grafting include Reverdin pinch grafting, Ollier grafting, Thiersch grafting, Wolfe grafting, Padgett dermatome and modifications, Meek-wall microdermatome and Tanner mesh grafting. A brief description of the usage, advantages and limitations of each technique is included in the manuscript. Skin grafting technique have evolved significantly over past 200 years from Reverdin pinch grafting to modern day meshed skin grafts using powered dermatome. Increasing the expansion ratio and improving the cosmetic and functional outcome are the main focus of ongoing skin grafting research and emerging techniques (such as Integra ® , Recell ® , Xpansion ® ) are showing promise. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  12. Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting.

    Science.gov (United States)

    Abdel Aal, Mohamed; ElNahal, Nezar; Bakir, Bakir Moustafa; Fouda, Mohamed

    2011-04-01

    Cardiopulmonary bypass (CPB) using a closed circuit system with minimal priming volume can be a solution to ameliorate adverse effects of CPB. We hypothesize that the use of mini-bypass in routine coronary artery bypass grafting (CABG) reduces homologous blood product use and postoperative bleeding. The study is designed to determine the differences in blood loss and transfusion requirements associated with a minimized CPB circuit vs. a standard bypass circuit. From February 2009 to August 2009, 80 patients were prospectively randomized to undergo elective CABG. Group A included 40 patients who had the minimized bypass circuit (Medtronic Resting Heart Circuit). Group B had an equal number of patients who had the standard CPB circuit (Stockert III, SEC.BM). Laboratory parameters for hemoglobin, hematocrit and platelet count were measured at baseline after initiation of CPB and after bypass. Blood usage was controlled by study-specific protocol (transfusion for hemoglobin platelets (1.95±2.95 units vs. 3.23±2.85), and postoperative drainage in 24 hours (531.62±220.12 ml vs. 729±294.9 ml, P<0.05). The hematocrit was 33±5% in group A, and 27±1% in group B. There was statistical differences seen in the mean hemoglobin level which was 10.19±0.65 g/dl in group A, and 9.4±0.68 g/dl in group B. There was statistical difference in the duration of ventilation, length of ICU stay. The requirement of inotropic support was lower in group A. The adoption of mini-bypass significantly reduces morbidity including donor blood usage and postoperative bleeding in routine CABG patients.

  13. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis.

    Science.gov (United States)

    Adam, Frank; Pape, Dietrich; Schiel, Karin; Steimer, Oliver; Kohn, Dieter; Rupp, Stefan

    2004-01-01

    Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic. The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD). Controlled laboratory study with roentgen stereometric analysis (RSA). Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA. Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38mm (HBS), and 1.85mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load. Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel. Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.

  14. Coping with uncertainty in environmental impact assessments: Open techniques

    NARCIS (Netherlands)

    Chivatá Cárdenas, Ibsen; Halman, Johannes I.M.

    2016-01-01

    Uncertainty is virtually unavoidable in environmental impact assessments (EIAs). From the literature related to treating and managing uncertainty, we have identified specific techniques for coping with uncertainty in EIAs. Here, we have focused on basic steps in the decision-making process that take

  15. Impact of Short Hepatic Vein Reconstruction in Living Donor Adult Liver Transplantation Using a Left Liver Plus Caudate Lobe Graft

    Directory of Open Access Journals (Sweden)

    Koji Mikami

    2010-01-01

    Conclusion: Although no definite advantage from the V1 reconstruction was demonstrated, hepatic vein reconstruction with a significantly-sized short hepatic vein might provide an additional margin of safety for marginally-sized liver grafts during the early phase of graft regeneration.

  16. Delayed graft duodenal perforation due to impacted food five years after simultaneous pancreas-kidney transplantation: A case report

    Directory of Open Access Journals (Sweden)

    Taizo Sakata

    2017-01-01

    Conclusion: When a patient is stable, even in the presence of delayed duodenal graft perforation, graft excision may not be necessary. Intraoperative exploration should include Doppler ultrasound examination of the vasculature to rule out thrombosis as a contributor to ischemia. Tissue biopsy should be performed to diagnose rejection.

  17. Methods and techniques for prediction of environmental impact

    International Nuclear Information System (INIS)

    1992-04-01

    Environmental impact assessment (EIA) is the procedure that helps decision makers understand the environmental implications of their decisions. The prediction of environmental effects or impact is an extremely important part of the EIA procedure and improvements in existing capabilities are needed. Considerable attention is paid within environmental impact assessment and in handbooks on EIA to methods for identifying and evaluating environmental impacts. However, little attention is given to the issue distribution of information on impact prediction methods. The quantitative or qualitative methods for the prediction of environmental impacts appear to be the two basic approaches for incorporating environmental concerns into the decision-making process. Depending on the nature of the proposed activity and the environment likely to be affected, a combination of both quantitative and qualitative methods is used. Within environmental impact assessment, the accuracy of methods for the prediction of environmental impacts is of major importance while it provides for sound and well-balanced decision making. Pertinent and effective action to deal with the problems of environmental protection and the rational use of natural resources and sustainable development is only possible given objective methods and techniques for the prediction of environmental impact. Therefore, the Senior Advisers to ECE Governments on Environmental and Water Problems, decided to set up a task force, with the USSR as lead country, on methods and techniques for the prediction of environmental impacts in order to undertake a study to review and analyse existing methodological approaches and to elaborate recommendations to ECE Governments. The work of the task force was completed in 1990 and the resulting report, with all relevant background material, was approved by the Senior Advisers to ECE Governments on Environmental and Water Problems in 1991. The present report reflects the situation, state of

  18. Ar-Ar dating techniques for terrestrial meteorite impacts

    Science.gov (United States)

    Kelley, S. P.

    2003-04-01

    The ages of the largest (>100 km) known impacts on Earth are now well characterised. However the ages of many intermediate sized craters (20-100 km) are still poorly known, often the only constraints are stratigraphic - the difference between the target rock age and the age of crater filling sediments. The largest impacts result in significant melt bodies which cool to form igneous rocks and can be dated using conventional radiometric techniques. Smaller impacts give rise to thin bands of melted rock or melt clasts intimately mixed with country rock clasts in breccia deposits, and present much more of a challenge to dating. The Ar-Ar dating technique can address a wide variety of complex and heterogeneous samples associated with meteorite impacts and obtain reasonable ages. Ar-Ar results will be presented from a series of terrestrial meteorite impact craters including Boltysh (65.17±0.64 Ma, Strangways (646±42 Ma), and St Martin (220±32 Ma) and a Late Triassic spherule bed, possibly representing distal deposits from Manicouagan (214±1 Ma) crater. Samples from the Boltysh and Strangways craters demonstrate the importance of rapid cooling upon the retention of old ages in glassy impact rocks. A Late Triassic spherule bed in SW England is cemented by both carbonate and K-feldspar cements allowing Ar-Ar dating of fine grained cement to place a mimimum age upon the age of the associated impact. An age of 214.7±2.5 Ma places the deposit with errors of the age of the Manicouagan impact, raising the possibility that it may represent a distal deposit (the deposit lay around 2000 km away from the site of the Manicouagan crater during the Late Triassic). Finally the limits of the technique will be demonstrated using an attempt to date melt rocks from the St Martin Crater in Canada.

  19. Factors impacting short and long-term kidney graft survival: modification by single intra-operative -high-dose induction with ATG-Fresenius.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2011-01-01

    A majority of recipients benefited from the intra-operative single high-dose induction (HDI) with ATG-Fresenius (ATG-F) still leaving a group of recipients who did not profit from this kind of induction. Therefore the aim of this retrospective analysis was 1st to identify the risk factors impacting short and long-term graft survival, and 2nd to assess the efficacy of this type of induction in kidney graft recipients with or without these risk factors. A total of 606 recipients receiving two different immunosuppressive treatment regimens (1st: Triple drug therapy [TDT, n=196] consisting mainly of steroids, azathioprine and cyclosporine; 2nd: TDT + 9 mg/kg ATG-F intra-operatively [HDI, n=410]) were included in this analysis and grouped according to their kidney graft survival time (short GST: ≤1 yr, n=100 and long GST: >5 yrs, n=506). The main risk factors associated with a shortened graft survival were pre-transplant sensitization, re-transplantation, rejections (in particular vascular or mixed ones) and the necessity of a long-term anti-rejection therapy. Adding ATG-F single high dose induction to TDT was more efficient in prolonging kidney graft survival than TDT alone not only in recipients without any risk factors (p<0.005) but also in recipients with at least one risk factor (p<0.021). Only in 4.6% of recipients having two or more risk factors this effect could not be demonstrated. The intra-operative single high-dose induction with ATG-F significantly improves the kidney graft survival in recipients with or without risk factors and can therefore be recommended.

  20. Piezoelectric Versus Conventional Rotary Techniques for Impacted Third Molar Extraction

    Science.gov (United States)

    Jiang, Qian; Qiu, Yating; Yang, Chi; Yang, Jingyun; Chen, Minjie; Zhang, Zhiyuan

    2015-01-01

    Abstract Impacted third molars are frequently encountered in clinical work. Surgical removal of impacted third molars is often required to prevent clinical symptoms. Traditional rotary cutting instruments are potentially injurious, and piezosurgery, as a new osteotomy technique, has been introduced in oral and maxillofacial surgery. No consistent conclusion has been reached regarding whether this new technique is associated with fewer or less severe postoperative sequelae after third molar extraction. The aim of this study was to compare piezosurgery with rotary osteotomy techniques, with regard to surgery time and the severity of postoperative sequelae, including pain, swelling, and trismus. We conducted a systematic literature search in the Cochrane Library, PubMed, Embase, and Google Scholar. The eligibility criteria of this study included the following: the patients were clearly diagnosed as having impacted mandibular third molars; the patients underwent piezosurgery osteotomy, and in the control group rotary osteotomy techniques, for removing impacted third molars; the outcomes of interest include surgery time, trismus, swelling or pain; the studies are randomized controlled trials. We used random-effects models to calculate the difference in the outcomes, and the corresponding 95% confidence interval. We calculated the weighted mean difference if the trials used the same measurement, and a standardized mean difference if otherwise. A total of seven studies met the eligibility criteria and were included in our analysis. Compared with rotary osteotomy, patients undergoing piezosurgery experienced longer surgery time (mean difference 4.13 minutes, 95% confidence interval 2.75–5.52, P piezosurgery groups. The number of included randomized controlled trials and the sample size of each trial were relatively small, double blinding was not possible, and cost analysis was unavailable due to a lack of data. Our meta-analysis indicates that although patients

  1. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  2. Polyether/Polyester Graft Copolymers

    Science.gov (United States)

    Bell, Vernon L., Jr.; Wakelyn, N.; Stoakley, D. M.; Proctor, K. M.

    1986-01-01

    Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

  3. The impact of pretransplant donor-specific antibodies on graft outcome in renal transplantation: a six-year follow-up study

    Directory of Open Access Journals (Sweden)

    Elias David-Neto

    2012-01-01

    Full Text Available OBJECTIVE: The significance of pretransplant, donor-specific antibodies on long-term patient outcomes is a subject of debate. This study evaluated the impact and the presence or absence of donor-specific antibodies after kidney transplantation on short- and long-term graft outcomes. METHODS: We analyzed the frequency and dynamics of pretransplant donor-specific antibodies following renal transplantation from a randomized trial that was conducted from 2002 to 2004 and correlated these findings with patient outcomes through 2009. Transplants were performed against a complement-dependent T- and B-negative crossmatch. Pre- and posttransplant sera were available from 94 of the 118 patients (80%. Antibodies were detected using a solid-phase (LuminexH, single-bead assay, and all tests were performed simultaneously. RESULTS: Sixteen patients exhibited pretransplant donor-specific antibodies, but only 3 of these patients (19% developed antibody-mediated rejection and 2 of them experienced early graft losses. Excluding these 2 losses, 6 of 14 patients exhibited donor-specific antibodies at the final follow-up exam, whereas 8 of these patients (57% exhibited complete clearance of the donor-specific antibodies. Five other patients developed ''de novo'' posttransplant donor-specific antibodies. Death-censored graft survival was similar in patients with pretransplant donor-specific and non-donor-specific antibodies after a mean follow-up period of 70 months. CONCLUSION: Pretransplant donor-specific antibodies with a negative complement-dependent cytotoxicity crossmatch are associated with a risk for the development of antibody-mediated rejection, although survival rates are similar when patients transpose the first months after receiving the graft. Our data also suggest that early posttransplant donor-specific antibody monitoring should increase knowledge of antibody dynamics and their impact on long-term graft outcome.

  4. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [KFKI-AEKI Applied Reactor Physics, Budapest (Hungary); Pazsit, I. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Reactor Physics

    1997-12-08

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source code written in MATLAB are available at a public ftp site. The necessary information to reproduce the simulation results is also reported. (author).

  5. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Pazsit, I

    1998-04-01

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source codes written in MATLAB[reg] are available at a public ftp site. The necessary information to reproduce the simulation results is also reported.

  6. Coping with uncertainty in environmental impact assessments: Open techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, Ibsen C., E-mail: c.cardenas@utwente.nl [IceBridge Research Institutea, Universiteit Twente, P.O. Box 217, 7500 AE Enschede (Netherlands); Halman, Johannes I.M., E-mail: J.I.M.Halman@utwente.nl [Universiteit Twente, P.O. Box 217, 7500 AE Enschede (Netherlands)

    2016-09-15

    Uncertainty is virtually unavoidable in environmental impact assessments (EIAs). From the literature related to treating and managing uncertainty, we have identified specific techniques for coping with uncertainty in EIAs. Here, we have focused on basic steps in the decision-making process that take place within an EIA setting. More specifically, we have identified uncertainties involved in each decision-making step and discussed the extent to which these can be treated and managed in the context of an activity or project that may have environmental impacts. To further demonstrate the relevance of the techniques identified, we have examined the extent to which the EIA guidelines currently used in Colombia consider and provide guidance on managing the uncertainty involved in these assessments. Some points that should be considered in order to provide greater robustness in impact assessments in Colombia have been identified. These include the management of stakeholder values, the systematic generation of project options, and their associated impacts as well as the associated management actions, and the evaluation of uncertainties and assumptions. We believe that the relevant and specific techniques reported here can be a reference for future evaluations of other EIA guidelines in different countries. - Highlights: • uncertainty is unavoidable in environmental impact assessments, EIAs; • we have identified some open techniques to EIAs for treating and managing uncertainty in these assessments; • points for improvement that should be considered in order to provide greater robustness in EIAs in Colombia have been identified; • the paper provides substantiated a reference for possible examinations of EIAs guidelines in other countries.

  7. Coping with uncertainty in environmental impact assessments: Open techniques

    International Nuclear Information System (INIS)

    Cardenas, Ibsen C.; Halman, Johannes I.M.

    2016-01-01

    Uncertainty is virtually unavoidable in environmental impact assessments (EIAs). From the literature related to treating and managing uncertainty, we have identified specific techniques for coping with uncertainty in EIAs. Here, we have focused on basic steps in the decision-making process that take place within an EIA setting. More specifically, we have identified uncertainties involved in each decision-making step and discussed the extent to which these can be treated and managed in the context of an activity or project that may have environmental impacts. To further demonstrate the relevance of the techniques identified, we have examined the extent to which the EIA guidelines currently used in Colombia consider and provide guidance on managing the uncertainty involved in these assessments. Some points that should be considered in order to provide greater robustness in impact assessments in Colombia have been identified. These include the management of stakeholder values, the systematic generation of project options, and their associated impacts as well as the associated management actions, and the evaluation of uncertainties and assumptions. We believe that the relevant and specific techniques reported here can be a reference for future evaluations of other EIA guidelines in different countries. - Highlights: • uncertainty is unavoidable in environmental impact assessments, EIAs; • we have identified some open techniques to EIAs for treating and managing uncertainty in these assessments; • points for improvement that should be considered in order to provide greater robustness in EIAs in Colombia have been identified; • the paper provides substantiated a reference for possible examinations of EIAs guidelines in other countries.

  8. The Impact of Timing and Graft Dysfunction on Survival and Cardiac Allograft Vasculopathy in Antibody Mediated Rejection

    Science.gov (United States)

    Clerkin, Kevin J.; Restaino, Susan W.; Zorn, Emmanuel; Vasilescu, Elena R.; Marboe, Charles C.; Mancini, Donna M.

    2017-01-01

    Background Antibody mediated rejection (AMR) has been associated with increased mortality and cardiac allograft vasculopathy (CAV). Early studies suggested that late AMR was rarely associated with graft dysfunction while recent reports have demonstrated an association with increased mortality. We sought to investigate the timing of AMR and its association with graft dysfunction, mortality, and CAV. Methods This retrospective cohort study identified all adult heart transplant recipients at Columbia University Medical Center from 2004–2013 (689 patients). There were 68 primary cases of AMR, which were stratified by early (1-year post-OHT) AMR. Kaplan-Meier survival analysis and modeling was performed with multivariable logistic regression and Cox proportional hazards regression. Results From January 1, 2004 through October 1, 2015 43 patients had early AMR (median 23 days post-OHT) and 25 had late AMR (median 1084 days post-OHT). Graft dysfunction was less common with early compared with late AMR (25.6% vs. 56%, p=0.01). Patients with late AMR had decreased post-AMR survival compared with early AMR (1-year 80% vs. 93%, 5-year 51% vs. 73%, p<0.05). When stratified by graft dysfunction, only those with late AMR and graft dysfunction had worse survival (30-day 79%, 1-year 64%, and 5-year 36%, p<0.006). The association remained irrespective of age, sex, DSA, LVAD use, reason for OHT, and recovery of graft function. Similarly, those with late AMR and graft dysfunction had accelerated development of de-novo CAV (50% at 1 year, HR 5.42, p=0.009), while all other groups were all similar to the general transplant population. Conclusion Late AMR is frequently associated with graft dysfunction. When graft dysfunction is present in late AMR there is an early and sustained increased risk of mortality and rapid development of de-novo CAV despite aggressive treatment. PMID:27423693

  9. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  10. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  11. The impact of blood transfusions in deceased organ donors on the outcomes of 1,884 renal grafts from United Network for Organ Sharing Region 5.

    Science.gov (United States)

    de la Cruz, J Salvador; Sally, Mitchell B; Zatarain, John R; Crutchfield, Megan; Ramsey, Katrina; Nielsen, Jamison; Patel, Madhukar; Lapidus, Jodi; Orloff, Susan; Malinoski, Darren J

    2015-10-01

    Historically, strategies to reduce acute rejection and improve graft survival in kidney transplant recipients included blood transfusions (BTs) before transplantation. While advents in recipient immunosuppression strategies have replaced this practice, the impact of BTs in the organ donor on recipient graft outcomes has not been evaluated. We hypothesize that BTs in organ donors after neurologic determination of death (DNDDs) translate into improved recipient renal graft outcomes, as measured by a decrease in delayed graft function (DGF). Donor demographics, critical care end points, the use of BTs, and graft outcome data were prospectively collected on DNDDs from March 2012 to October 2013 in the United Network for Organ Sharing Region 5 Donor Management Database. Propensity analysis determined each DNDD's probability of receiving packed red blood cells based on demographic and critical care data as well as provider bias. The primary outcome measure was the rate of DGF (dialysis in the first week after transplantation) in different donor BT groups as follows: no BT, any BT, 1 to 5, 6 to 10, or greater than 10 packed red blood cell units. Regression models determined the relationship between donor BTs and recipient DGF after accounting for known predictors of DGF as well as the propensity to receive a BT. Data were complete for 1,884 renal grafts from 1,006 DNDDs; 52% received any BT, 32% received 1 to 5 U, 11% received 6 to 10, and 9% received greater than 10 U of blood. Grafts from transfused donors had a lower rate of DGF compared with those of the nontransfused donors (26% vs. 34%, p donors with any BT had a lower odds of DGF (odds ratio, 0.76; p = 0.030), and this effect was greatest in those with greater than 10 U transfused. Any BT in a DNDD was associated with a 23% decrease in the odds of recipients developing DGF, and this effect was more pronounced as the number of BTs increased. Therapeutic study, level III; epidemiologic/prognostic study, level II.

  12. Development of EPDM based thermoplastic elastomers for oil resistant applications: optimization of radiation grafting parameters

    International Nuclear Information System (INIS)

    Chaudhari, C.V.; Dubey, K.A.; Bhardwaj, Y.K.; Sabharwal, S.

    2008-01-01

    Full text: Ethylene-propylene diene terpolymer (EPDM) is currently among the most industrially useful elastomers because of its certain unique properties like excellent heat resistance, resistance towards ozone deterioration, high impact strength. However EPDM has a serious drawback of weak adhesion properties and tendency to swell in contact with paraffin oil and aromatic hydrocarbons. Blending EPDM with suitable polar elastomers or grafting polar polymer chains onto EPDM is an easy method to overcome this drawback. Radiation grafting of Acrylonitrile (ACN) on EPDM provides an easy and effective method of incorporating ACN uniformly on the EPDM backbone. Grafting of ACN on EPDM is expected to result grafted copolymer with better oil resistance, hardness and better compatibility with polar polymer matrices. In the present study radiation induced grafting of ACN onto EPDM rubber film was investigated by mutual radiation grafting technique. Effect of experimental variables viz. radiation dose, dose rate, types of solvents and monomer content on extent of grafting was studied. The solvent composition of Acetone:CCl 4 (20:80) was found to be the optimum mixture which resulted in highest degree of grafting. It was found that the degree of grafting increases with radiation dose, monomer content and decreases with dose rate

  13. MicroRNA-155 Modulates Acute Graft-versus-Host Disease by Impacting T Cell Expansion, Migration, and Effector Function.

    Science.gov (United States)

    Zitzer, Nina C; Snyder, Katiri; Meng, Xiamoei; Taylor, Patricia A; Efebera, Yvonne A; Devine, Steven M; Blazar, Bruce R; Garzon, Ramiro; Ranganathan, Parvathi

    2018-06-15

    MicroRNA-155 (miR-155) is a small noncoding RNA critical for the regulation of inflammation as well as innate and adaptive immune responses. MiR-155 has been shown to be dysregulated in both donor and recipient immune cells during acute graft-versus-host disease (aGVHD). We previously reported that miR-155 is upregulated in donor T cells of mice and humans with aGVHD and that mice receiving miR-155-deficient (miR155 -/- ) splenocytes had markedly reduced aGVHD. However, molecular mechanisms by which miR-155 modulates T cell function in aGVHD have not been fully investigated. We identify that miR-155 expression in both donor CD8 + T cells and conventional CD4 + CD25 - T cells is pivotal for aGVHD pathogenesis. Using murine aGVHD transplant experiments, we show that miR-155 strongly impacts alloreactive T cell expansion through multiple distinct mechanisms, modulating proliferation in CD8 + donor T cells and promoting exhaustion in donor CD4 + T cells in both the spleen and colon. Additionally, miR-155 drives a proinflammatory Th1 phenotype in donor T cells in these two sites, and miR-155 -/- donor T cells are polarized toward an IL-4-producing Th2 phenotype. We further demonstrate that miR-155 expression in donor T cells regulates CCR5 and CXCR4 chemokine-dependent migration. Notably, we show that miR-155 expression is crucial for donor T cell infiltration into multiple target organs. These findings provide further understanding of the role of miR-155 in modulating aGVHD through T cell expansion, effector cytokine production, and migration. Copyright © 2018 by The American Association of Immunologists, Inc.

  14. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  15. Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

    Science.gov (United States)

    Littell, Justin D.

    2010-01-01

    The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

  16. Immediate Reconstruction of Failed Implants in the Esthetic Zone Using a Flapless Technique and Autogenous Composite Tuberosity Graft

    NARCIS (Netherlands)

    Raghoebar, Gerry M; Meijer, Henny J A; van Minnen, Baucke; Vissink, Arjan

    We describe a technique for immediate reconstruction of bone after removal of failed dental implants in the esthetic region to optimize the esthetic outcome of retreatment. We conducted a study of 16 consecutive patients in whom the bony defect resulting from implant removal was immediately

  17. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  18. Impact of pig insemination technique and semen preparation on profitability.

    Science.gov (United States)

    Gonzalez-Peña, D; Knox, R V; Pettigrew, J; Rodriguez-Zas, S L

    2014-01-01

    Artificial insemination technique and semen preparation impact boar utilization efficiency, genetic dissemination, and biosecurity. Intrauterine (IUI) and deep intrauterine (DUI) AI techniques require lower number of spermatozoa per dose compared to conventional (CON) AI. Frozen semen (FRO) has been associated with lower reproductive performance compared to fresh semen (FRE) preparation. The combined effects of 3 AI techniques (CON, IUI, and DUI) and 2 semen preparations (FRE and FRO) on the financial indicators of a pig crossbreeding system were studied. A 3-tier system was simulated in ZPLAN and the genetic improvement in a representative scenario was characterized. The cross of nucleus lines B and A generated 200,000 BA sows at the multiplier level. The BA sows were inseminated (CON, IUI, or DUI) with FRE or FRO from line C boars at the commercial level. Semen preparation and AI technique were represented by distinct sow:boar ratios in the C × BA cross. A range of farrowing rates (60 to 90%) and litter sizes (8 to 14 liveborn pigs) were tested. Genetic improvement per year for number born alive, adjusted 21-d litter weight, days to 113.5 kg, backfat, and ADG were 0.01 pigs per litter, 0.06 kg, -0.09 d, -0.29 mm, and 0.88 g, respectively. On average, the net profit for FRE (FRO) increased (P-value profit between techniques were driven by differences in costs. Differences in fixed costs between IUI and DUI relative to CON were -2.4 (-5.2%) and -3.4% (-7.4%), respectively. The differences in total costs between FRE and FRO were lower than -5%. The difference in variable costs between FRE and FRO ranged from -5.3 (CON) to -24.7% (DUI). Overall, insemination technique and semen preparation had a nonlinear effect on profit. The average relative difference in profit between FRE and FRO was less than 3% for the scenarios studied.

  19. Plate Fixation With Autogenous Calcaneal Dowel Grafting Proximal Fourth and Fifth Metatarsal Fractures: Technique and Case Series.

    Science.gov (United States)

    Seidenstricker, Chad L; Blahous, Edward G; Bouché, Richard T; Saxena, Amol

    Metaphyseal and proximal diaphyseal fractures of the lateral column metatarsals can have problems with healing. In particular, those involving the fifth metatarsal have been associated with a high nonunion rate with nonoperative treatment. Although intramedullary screw fixation results in a high union rate, delayed healing and complications can occur. We describe an innovative technique to treat both acute and chronic injuries involving the metatarsal base from the metaphysis to the proximal diaphyseal bone of the fourth and fifth metatarsals. The surgical technique involves evacuation of sclerotic bone at the fracture site, packing the fracture site with compact cancellous bone, and plate fixation. In our preliminary results, 4 patients displayed 100% radiographic union at a mean of 4.75 (range 4 to 6) weeks with no incidence of refracture, at a mean follow-up point of 3.5 (range 1 to 5) years. The early results with our small series suggest that this technique is a useful treatment choice for metaphyseal and proximal diaphyseal fractures of the fourth and fifth metatarsals. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. A comparison of direct technique with the liquid stylet technique of radial artery cannulation in patients presenting for coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Younus, U.; Ahmed, I.

    2012-01-01

    To compare direct technique with the liquid stylet technique of radial artery cannulation in patients undergoing coronary artery byroms grouping. We hypothesized that liquid stylet technique would lead to fewer attempts and save vital time. Study Design: Randomized controlled Trial (RCT). Place and Duration of Study: Department of Anaesthesia and Intensive Care, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, [AFIC-NIHD] Rawalpindi, between 1 July 2007 to 31 Dec 2007. Patients and Methods: One hundred patients of either sex scheduled for CABG were included and were randomized to 2 groups using random number table. Fifty patients in the direct technique group and 50 in the liquid stylet group. Results: These two groups comparable with respect to age, gender and weight were studied. The number of attempts in group 1 were 1.7+-0.5 vs 3.6+-1.6 in groups 2, (p=0.021). The time consumed in group was 3.3 +- 2.2 minutes while in groups 2 it was 8.0 +- 3.6 (p=0.022). Conclusion: We concluded that the liquid stylet technique is safe, quick and is associated with lesser number of attempts at cannulation. Secondly it can be done without fancy guide wires and other technology especially in a developing country like Pakistan. (author)

  1. Grafting the alar rim: application as anatomical graft.

    Science.gov (United States)

    Gruber, Ronald P; Fox, Paige; Peled, Anne; Belek, Kyle A

    2014-12-01

    Alar rim contour and alar rim grafts have become essential components of rhinoplasty. Ideally, grafts of the nose should be anatomical in shape. So doing might make grafts of the alar rim more robust. The authors considered doing that by applying the graft as a continuous extension of the lateral crus. Twelve patients (two men and 10 women) constituted the study group (seven primary and five secondary cases). Of those, there were five concave rims, two concave rims with rim retraction, two boxy tips, and three cephalically oriented lateral crura. Surgical technique included the following: (1) an open approach was used; (2) a marginal incision that ignored the caudal margin of the lateral crus (the incision went straight posteriorly to a point 5 to 6 mm from the rim margin) was used; (3) a triangular graft was made to cover the exposed vestibular skin; (4) it was secured end to end to the caudal border of the lateral crus; and (5) the poster end was allowed to sit in a small subcutaneous pocket. Follow-up was 11 to 19 months. All 12 patients exhibited good rims as judged by a blinded panel. Rim retraction was not fully corrected in one patient, but no further treatment was required. One patient did require a secondary small rim graft for residual rim concavity. The concept of grafting the alar rim is strongly supported by the authors' results. The modifications the authors applied by designing the graft to be anatomical in shape has been a technical help.

  2. Medial Patellofemoral Ligament Reconstruction: Impact of Knee Flexion Angle During Graft Fixation on Dynamic Patellofemoral Contact Pressure-A Biomechanical Study.

    Science.gov (United States)

    Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander

    2018-04-01

    Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the

  3. Transurethral ventral buccal mucosa graft inlay urethroplasty for reconstruction of fossa navicularis and distal urethral strictures: surgical technique and preliminary results.

    Science.gov (United States)

    Nikolavsky, Dmitriy; Abouelleil, Mourad; Daneshvar, Michael

    2016-11-01

    To introduce a novel surgical technique for the reconstruction of distal urethral strictures using buccal mucosal graft (BMG) through a transurethral approach. A retrospective institution chart review was conducted of all the patients who underwent a transurethral ventral BMG inlay urethroplasty from March 2014 to March 2016. Patients with greater than one-year follow-up were included. Steps of the procedure: transurethral ventral wedge resection of the stenosed segment and transurethral delivery and spread fixation of appropriate BMG inlay into the resultant urethrotomy. The patients were followed for post-operative complications and stricture recurrence with uroflow, PVR, cystoscopy and outcome questionnaires. Three patients with a minimum of 12-month follow-up are included in this case series. The mean age of the patients was 42 years (35-53); mean stricture length was 2.1 cm (1-4). All patients had at least 2 previous failed procedures. Mean follow-up was 18 months (12-24). There were no stricture recurrences or fistula. Mean pre- and post-operative uroflow values were 4.3 (0-8) and 19 (16-26), respectively. Neither penile chordee nor changes in sexual function were noted in patients on follow-up. Transurethral ventral BMG inlay urethroplasty is a feasible option for treatment of fossa navicularis strictures. This single-stage technique allows for avoiding skin incision or urethral mobilization. It helps to prevent glans dehiscence, fistula formation and avoids the use of genital skin flaps in all patients, especially those affected with LS. This novel surgical technique is an effective treatment alternative for men with distal urethral strictures.

  4. Impact of contrast injection and stent-graft implantation on reproducibility of volume measurements in semiautomated segmentation of abdominal aortic aneurysm on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Morin-Roy, Florence; Hadjadj, Sofiane; Thomas, Olivier; Yang, Dan Yang [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); Kauffmann, Claude [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Tang, An [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Saint-Luc, Department of Radiology, Montreal, Quebec (Canada); Piche, Nicolas [Object Research System, Montreal, Quebec (Canada); Elkouri, Stephane [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Vascular surgery, Montreal, Quebec (Canada); Therasse, Eric [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Radiology, Montreal, Quebec (Canada); Soulez, Gilles [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada)

    2014-07-15

    To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. (orig.)

  5. Impacts of radiation management techniques on the North Atlantic Oscillation

    Science.gov (United States)

    Adakudlu, Muralidhar; Helge Otterå, Odd; Tjiputra, Jerry; Muri, Helene; Grini, Alf; Schulz, Michael

    2017-04-01

    The effectiveness of various climate engineering techniques in limiting the global warming signal to reasonable levels has been the topic of state-of-the-art research on climate change. Using an Earth system model, we show that these techniques have the potential to bring down the high CO2 concentration climate in RCP8.5 to a moderate climate similar to RCP4.5 in terms of global temperature. Nevertheless, their influence on the regional aspects of atmospheric circulation is not clear. The regional circulation patterns in the atmosphere are largely characterized by the natural variability modes, such as the North Atlantic Oscillation (NAO). In this study, we assess the impacts of three radiation managment techniques, namely, Stratospheric Aerosol Injection (SAI), Marine Sky Brightening (MSB) and Cirrus Cloud Thinning (CCT), on the structure and features of the NAO. The results indicate an east-northeastward shift as well as intensification of the NAO spatial pattern in the global warming scenarios of RCP4.5 and RCP8.5, with the signal being most intense in the latter. The climate engineering forcings when applied to the RCP8.5 case tend to reduce the strength of the NAO with little impact on its position. The CCT case appears to have the maximum effect on the NAO signal. The patterns of cloud radiative forcing, expressed as the difference between net radiative forcing at TOA under average conditions and clear sky conditions, reveal a northeastward shift of the radiative heating in the north Atlantic region. This implies a possible link between the changes in the NAO signal and the cloud radiative forcing.

  6. Homogeneous cation exchange membrane by radiation grafting

    International Nuclear Information System (INIS)

    Kolhe, Shailesh M.; G, Agathian; Ashok Kumar

    2001-01-01

    Preparation of a strong cation exchange membrane by radiation grafting of styrene on to polyethylene (LDPE) film by mutual irradiation technique in the presence of air followed by sulfonation is described. The grafting has been carried out in the presence of air and without any additive. Low dose rate has been seen to facilitate the grafting. Further higher the grafting percentage more is the exchange capacity. The addition of a swelling agent during the sulfonation helped in achieving the high exchange capacity. The TGA-MASS analysis confirmed the grafting and the sulfonation. (author)

  7. Impact of graft loss among kidney diseases with a high risk of post-transplant recurrence in the paediatric population

    DEFF Research Database (Denmark)

    Van Stralen, Karlijn J; Verrina, Enrico; Belingheri, Mirco

    2013-01-01

    Some kidney diseases tend to recur in the renal allograft after transplantation. We studied the risk of graft loss among primary renal diseases known for their high risk of recurrence and compared it with that of patients with hypoplasia and/or dysplasia....

  8. Relative Composition of Fibrous Connective and Fatty/Glandular Tissue in Connective Tissue Grafts Depends on the Harvesting Technique but not the Donor Site of the Hard Palate.

    Science.gov (United States)

    Bertl, Kristina; Pifl, Markus; Hirtler, Lena; Rendl, Barbara; Nürnberger, Sylvia; Stavropoulos, Andreas; Ulm, Christian

    2015-12-01

    Whether the composition of palatal connective tissue grafts (CTGs) varies depending on donor site or harvesting technique in terms of relative amounts of fibrous connective tissue (CT) and fatty/glandular tissue (FGT) is currently unknown and is histologically assessed in the present study. In 10 fresh human cadavers, tissue samples were harvested in the anterior and posterior palate and in areas close to (marginal) and distant from (apical) the mucosal margin. Mucosal thickness, lamina propria thickness (defined as the extent of subepithelial portion of the biopsy containing ≤25% or ≤50% FGT), and proportions of CT and FGT were semi-automatically estimated for the entire mucosa and for CTGs virtually harvested by split-flap (SF) preparation minimum 1 mm deep or after deepithelialization (DE). Palatal mucosal thickness, ranging from 2.35 to 6.89 mm, and histologic composition showed high interindividual variability. Lamina propria thickness (P >0.21) and proportions of CT (P = 0.48) and FGT (P = 0.15) did not differ significantly among the donor sites (anterior, posterior, marginal, apical). However, thicker palatal tissue was associated with higher FGT content (P tissue composition in the hard palate, DE-harvested CTG contains much larger amounts of CT and much lower amounts of FGT than SF-harvested CTG, irrespective of the harvesting site.

  9. Reconstruction of irradiated mandible after segmental resection of osteoradionecrosis-a technique employing a microvascular latissimus dorsi flap and subsequent particulate iliac bone grafting

    DEFF Research Database (Denmark)

    Hillerup, Soren; Elberg, Jens Jorgen; Thorn, Jens Jorgen

    2014-01-01

    patients had a subsequent bone grafting from the posterior ileum for repair of defects up to 14 cm length. Three patients had no bone graft for various reasons. In three patients dental rehabilitation was achieved with implant supported prosthodontic appliances. Ten patients met the success criteria......, and the defect site was primed with a LD musculocutaneous flap wrapped around the reconstruction plate to bring in vascularized tissue and optimize healing conditions for a subsequent particulate iliac free bone graft reconstruction. The management of defect closure was successful in all 15 patients. Twelve...

  10. Oxidative stress and homocyteine metabolism following coronary artery grafting by on pump and off pump CABG techniques

    International Nuclear Information System (INIS)

    Parvizi, R.; Noubar, R.; Salmasi, H.S.

    2007-01-01

    To compare the effect of on-pump and off-pump CABG on the induction of the oxidative stress and the metabolism of homocysteine, which is involved in the synthesis of glutathione. This retrospective study was performed in Shahid Madani Heart Hospital in Tabriz, Iran in 2004 using a questionnaire. Plasma homocysteine, folate total antioxidant capacity (TAC) and malonedialdehyde (MDA) were determined on blood samples obtained from 40 patients undergoing CABG, preoperatively and at 0,12,48,120 hours and 6 months after surgery. The patients were divided into two matched groups, one off-pump and the other on-pump CABG. A marked reduction of homocysteine, folate and significant elevation of MDA were noticed at 0, 12, 48 hours after operation in the both groups (P<0.05). A negative and marked correlation between homocysteine and TAC but a positive and significant between homocysteinc and MDA were observed (P<0.05 in the both groups). In CABG operation because of oxidative stress and consumption of GSH immediate reduction in the plasma levels of homocyticine occurs in the both techniques. However using off pump CABG induction of oxidative stress and changes in plasma levels of homocysteine are not as high as on- pump CABG. (author)

  11. Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

    Science.gov (United States)

    Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim

    2013-08-26

    Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only

  12. Dose-dependent variations in blood flow evaluation of canine nerve, nerve graft, tendon, and ligament tissue by the radiolabeled-microsphere technique

    International Nuclear Information System (INIS)

    Riggi, K.; Wood, M.B.; Ilstrup, D.M.

    1990-01-01

    This study evaluates the dose-dependent accuracy of the radionuclide-labeled microsphere technique for blood flow evaluation in nerve, tendon, and ligament. In eight dogs, blood flows were determined for nerve, nerve graft, tendon, and ligament tissue by simultaneous injection of high- and low-dose microspheres with different radiolabels. The results demonstrated no significant differences in blood flow as measured from the small number of microspheres (less than 400) and the high number (more than 400) for nerve and tendon tissue. For nerve tissue, microsphere counts of 50 to 100, 100 to 200, 200 to 300, and more than 300 produced mean percentage errors of 12.74% (n = 5, SEM = 4.52), 5.45% (n = 13, SEM = 1.22), 10.22% (n = 6, SEM = 4.37), and 17.08% (n = 12, SEM = 3.30), respectively. For tendon tissue, the same microsphere subdivisions had mean percentage errors of 7.47% (n = 4, SEM = 2.66), 3.63% (n = 6, SEM = 1.34), 15.54% (n = 4, SEM = 4.43), and 12.91% (n = 1), respectively. For ligament tissue, percentage errors were consistently higher; microsphere counts of 30 to 100, 100 to 200, and 200 to 300 produced mean errors of 20.14% (n = 4, SEM = 6.38), 18.66% (n = 4, SEM = 6.24), and 25.78% (n = 2, SEM = 1.97), respectively. Although there was no direct relationship between percentage error and number of microspheres retrieved, we suggest that microsphere counts in the range of 100 to 200 should be considered acceptable for nerve and tendon in the canine. Ligament tissue seems to be less well suited to the microsphere technique; however, further study is warranted

  13. Development of Graft Copolymer Flocculant Based on Acrylamide and Acrylic Acid for the dewatering of coal

    International Nuclear Information System (INIS)

    Mahmoud, G.A.; Abdel Khalek, M.A

    2012-01-01

    Most coal preparation processes were carried out in water medium. The water content of coal product has a negative impact on handling and specific energy value. The moisture content may be attributed to the proportion of fine coal, which presents the greatest dewatering problem. A novel polymeric flocculant has been developed by graft copolymerization of acrylamide (AAm) with acrylic acid (AAc) using gamma irradiation technique. The grafted copol621621ymer P(AAm/AAc) was characterized by Fourier-transform infrared spectroscopy (FTIR), and thermo-gravimetric analysis (TGA). The effects of reaction parameters, such as total absorbed dose, and monomer concentration on grafting yield were investigated. The flocculation performance of the graft copolymer P(AAm/AAc) was investigated in coal suspension. It was observed that the grafting ratio was one of the key factors for the flocculating effects. The copolymers with various grafting ratios showed different flocculating properties. It was found that as the grafting ratio increased, the flocculating effect also increased. The flocculation performance of the grafted copolymer was better than that of the commercial flocculant, poly-acrylamide (Magnafloc 1011).

  14. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  15. Studies on radiation-induced graft polymerization

    International Nuclear Information System (INIS)

    Omichi, Hideki

    1978-09-01

    Radiation-induced graft polymerization is used extensively to improve physical properties of polymers, but few processes are now commercialized. The reason for this is partly inadequate basic research on the reaction and partly the difficulty in developing the grafting process with large radiation source. Firstly, new techniques are proposed of studying kinetics of the graft polymerization in heterogeneous system. Based on the grafting yield, the molecular weight of graft chains, and the amount of radicals given by ESR and activation analysis, kinetic parameters are obtained and the reaction mechanism of grafting process is discussed. Secondly, the development of grafting process of poly (vinyl chloride)-butadiene is described. By study of the reaction, process design, construction and operation of the pilot plant, and economic analysis of the process, this process with 60 Co gamma ray sources is shown to be industrially promising. (author)

  16. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  17. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    Science.gov (United States)

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Impact of lenalidomide-based induction therapy on the mobilization of CD34+ cells, blood graft cellular composition, and post-transplant recovery in myeloma patients: a prospective multicenter study.

    Science.gov (United States)

    Partanen, Anu; Valtola, Jaakko; Silvennoinen, Raija; Ropponen, Antti; Siitonen, Timo; Putkonen, Mervi; Sankelo, Marja; Pelkonen, Jukka; Mäntymaa, Pentti; Varmavuo, Ville; Jantunen, Esa

    2017-10-01

    Lenalidomide is an immunomodulatory drug that is also currently used in transplant-eligible patients with multiple myeloma. Previous studies have suggested a negative impact of lenalidomide on the mobilization of CD34 + cells. No data are available regarding the more detailed composition of blood grafts after lenalidomide. In a multicenter, prospective study, we analyzed the mobilization of CD34 + cells, graft cellular composition, and post-transplant hematologic recovery in 26 patients with multiple myeloma after lenalidomide-based induction and in 34 lenalidomide-naive controls with multiple myeloma. All patients were mobilized with low-dose cyclophosphamide plus granulocyte-colony-stimulating factor. The cellular composition of the grafts was analyzed from thawed, cryopreserved samples with flow cytometry. Graft function was evaluated by engraftment data and by complete blood counts until 12 months after the graft infusion. Patients in the lenalidomide arm had lower median peak CD34 + counts and approximately 40% lower CD34 + cell yields from the first apheresis session, but these differences were not significant. The median total number of CD34 + cells collected was comparable (6.4 vs. 7.5 × 10 6 /kg). The number of apheresis sessions was higher in the lenalidomide group (2 vs. 1; p = 0.039). The blood graft composition was comparable between the groups. Hematologic recovery within 12 months post-transplant did not differ between the groups. Lenalidomide-based induction seems to have an impact on the number of aphereses performed, but not on the total yields of the CD34 + cells in the graft. Neither cellular composition of the grafts nor post-transplant recovery was affected by the limited pre-transplant exposure to lenalidomide. © 2017 AABB.

  19. Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

    Directory of Open Access Journals (Sweden)

    Sedigheh Arta

    2017-04-01

    Full Text Available Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT in patients with coronary artery bypass (CABG surgery. Method: This randomized clinical trial was conducted on 60 participants undergoing coronary artery bypass grafting surgery in open-heart surgery ICU at Imam Reza hospital in Mashhad, Iran, in 2016. In continuous group, the arterial catheter was continuously irrigated with heparin solution at the rate of 2cc/h, and in the intermittent group with a syringe containing 5cc heparin solution every 3 hours. In both groups, catheter was monitored and recorded every 3 hours (until 48 hours and 3 times from enrollment in terms of complications of partial thromboplastin time. Data were analyzed using SPSS version 16. Results: The findingsof independent t-test showed that the two groups are homogeneous in age (P =0.48. The result of Fisher's exact test revealed no significant difference between the two groups in terms of average incidence of complications during the first 24 hours (P=0.55 and second 24 hours (P=0.55 after catheterization. Also during the 48 hours after surgery, independent t-test results showed no statistically significant difference in partial thromboplastin time (P=0.53 between the two groups. Implications for Practice: According to the results of the research based on the lack of difference between continuous and intermittent irrigation methods up to 48 hours after catheter replacement in terms of arterial catheter complications, further long-term follow-up researches are recommended.

  20. Mixing of nanosize particles by magnetically assisted impaction techniques

    Science.gov (United States)

    Scicolone, James V.

    approach based on use of small magnetic particles as mixing media is introduced that achieves a high-degree of mixing at scales of about a micron. The method is tested for binary mixture of alumina/silica and silica/titania. Various parameters such as processing time, size of the magnets, and magnetic particle to powder mixed ratio are considered. Experiments are carried out in batch containers in liquid and dry mediums, as well as a fluidized bed set-up. Homogeneity of Mixing (HoM), defined as the compliment of the Intensity of Segregation, was evaluated at the micron scale through field-emission scanning electron microscopy (FESEM) and the energy dispersive x-ray spectroscopy (EDS). Secondary electron images, along with elemental mappings, were used to visualize the change in agglomerate sizes. Compositional percent data of each element were obtained through an EDS spatial distribution point analysis and used to obtain quantitative analysis on the homogeneity of the mixture. The effect of magnet impaction on mixing quality was examined on the HoM of binary mixtures. The research shows that HoM improved with magnetically assisted impaction mixing techniques indicating that the HoM depends on the product of processing time with the number of magnets. In a fluidized bed set-up, MAIM not only improved dispersion, but it was also found that the magnetic particles served to break down the larger agglomerates, to reduce the minimum fluidization velocity, to delay the onset of bubbling, and to convert the fluidization behavior of ABF powder to APF. Thus MAIM techniques may be used to achieve mixing of nanopowders at a desired HoM through adjusting the number of magnets and processing time; and its inherent advantages are its simplicity, an environmentally benign operation, and reduced cost as compared with wet mixing techniques.

  1. Tunnel technique with connective tissue graft versus coronally advanced flap with enamel matrix derivative for root coverage: a RCT using 3D digital measuring methods. Part II. Volumetric studies on healing dynamics and gingival dimensions.

    Science.gov (United States)

    Rebele, Stephan F; Zuhr, Otto; Schneider, David; Jung, Ronny E; Hürzeler, Markus B

    2014-06-01

    The aim of this randomized clinical trial (RCT) was to compare the clinical performance of the tunnel technique with subepithelial connective tissue graft (TUN) versus a coronally advanced flap with enamel matrix derivative (CAF) in the treatment of gingival recession defects. The use of innovative 3D digital measuring methods allowed to study healing dynamics at connective tissue (CT)-grafted sites and to evaluate the influence of the thickness of the root covering soft tissues on the outcome of surgical root coverage. Twenty-four patients contributed a total of 47 Miller class I or II recessions for scientific evaluation. Precise study models collected at baseline and follow-up examinations were optically scanned and virtually superimposed for digital evaluation of clinical outcome measures including mean marginal soft tissue thickness (THK). Healing dynamics were measured in a defined region of interest at CT-grafted sites where volume differences between time points were calculated. At 12 months, recession reduction as well as mean root coverage were significantly better at CT-grafted sites treated in the TUN group (1.94 mm and 98.4% respectively) compared to the non-augmented sites of the CAF group (1.17 mm and 71.8% respectively) and statistical analysis revealed a positive correlation of THK (1.63 mm TUN versus 0.91 mm CAF, p tissue healing following surgical root coverage with CT-grafting was mainly accomplished after 6 months, with around two-thirds of the augmented volume being maintained after 12 months. The TUN resulted in thicker gingiva and better clinical outcomes compared to CAF. Increased gingival thickness was associated with better surgical outcomes in terms of recession reduction and root coverage. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  3. Spatial and temporal distribution of root activity of Ramphal (Annona reticulata) seedlings and their grafts with 'Arka Sahan' scion determined using isotopic technique

    International Nuclear Information System (INIS)

    Kotur, S.C.

    2009-01-01

    In both seedlings and grafts of Ramphal, early rainy season showed the highest intensity of root activity followed by late rainy season and winter. During early rainy season, the active roots were predominantly surface oriented and clustered towards the trunk in both seedlings and grafts. During later seasons, however, the roots migrated from 20cm to 40cm depth and from 40cm to 80 and 120cm radial distance that resulted in a uniform distribution of active roots throughout the rooting volume. The grafts of 'Arka Sahan' scion on Ramphal rootstocks showed deeper root activity which had nearly one-half of active roots close to the trunk at 40cm distance, that may be more drought tolerant than the seedlings. (author)

  4. Vascularized osseous graft for scaphoid

    International Nuclear Information System (INIS)

    Mendez Daza, Carlos Hernan; Mathoulin, Cristophe

    2004-01-01

    The most commonly used technique for treatment of pseudo-arthrosis of the scaphoid is osteo-synthesis with Kirschnet wires and cortical sponge grafts. Results reported by different teams using this procedure show no more than 90% osseous consolidation, especially in cases where vascularisation of the proximal fragment of the scaphoid is compromised. Here we present a series of ten cases of pseudo-arthrosis of the scaphoid, treated using a new surgical technique involving a vascularized osseous graft of the distal radius. Using this procedure we obtained 100% consolidation, with no complications either during the procedure or immediately post-operatively. Patients returned to work in week 15 on average. In 4 cases we observed discomfort in the area of the scar, which was successfully treated using local cortisone injection. The results obtained are very similar to those seen in the literature on the different techniques for vascularized osseous grafts for pseudo-arthrosis of the scaphoid

  5. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  6. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  7. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  8. Avaliação de diferentes métodos de sobre-enxertia na substituição da cultivar de macieira (Malus domestica Borkh. Gala por Princesa = Evaluation of different over-grafting techniques to replace 'Gala' for 'Princesa' apple trees (Malus domestica Borkh.

    Directory of Open Access Journals (Sweden)

    Fabiano Simões

    2006-10-01

    Full Text Available Foram comparados quatro métodos de enxertia: garfagem em inglês complicado (GIC; borbulhia lenhosa (BL; garfagem de topo (GT e garfagem meia-fenda esvaziada (GMFE, com o objetivo de avaliar o melhor método para execução da sobre-enxertia na substituição da cultivar de macieira Gala por Princesa. O experimento foi conduzido em São José dos Pinhais – PR, em seis macieiras localizadas em pomar com três anos de idade. As características avaliadas foram: porcentagem de pegamento dos enxertos, porcentagem de enxertos brotados, porcentagem de enxertos dormentes e porcentagem de enxertos mortos. O experimento foi finalizado após 62 dias da instalação. Após esse período conclui-se que a GIC apresentou maiores porcentagens de pegamento e brotação. Esta não se diferenciou da GT em relação à variável pegamento. A BL não é recomendada para a sobre-enxertia em macieiras.Four grafting methods were compared: whip graft, budding graft, cleft graft and the side graft, aiming at evaluating the best techniqueto replace ‘Gala’ for ‘Princesa’ apple trees. The experiment was held in São José dos Pinhais – PR in a 3-year old apple tree yard fruit. Six apple trees were selected for the experiment. The assessed characteristics were carried out by the percentage of grafting success (sprouted, sleeping grafts (no sprouts and dead ones. The experiment was concluded after 62 days of grafting. Results indicated that the budding graft showed to be more effective with a higher index of sprouting. This technique showed no difference concerning the sprouting percentage compared to the whip graft. The budding graft is not recommended to over–graft apple trees.

  9. A technique for measuring dynamic friction coefficient under impact loading.

    Science.gov (United States)

    Lin, Y L; Qin, J G; Chen, R; Zhao, P D; Lu, F Y

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m(2)/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  10. Cotton fibers encapsulated with homo- and block copolymers: synthesis by the atom transfer radical polymerization grafting-from technique and solid-state NMR dynamic investigations.

    Science.gov (United States)

    Castelvetro, Valter; Geppi, Marco; Giaiacopi, Simone; Mollica, Giulia

    2007-02-01

    Cotton fibers were modified by surface-initiated atom transfer radical polymerization of ethyl acrylate (EA) followed by copolymerization with styrene. Either ethyl 2-bromopropionate as a sacrificial free initiator or Cu(II) as a deactivator was used to optimize the EA grafting yield and to preserve the livingness of the chain ends for the subsequent growth of a poly(styrene) (PSty) block from the poly(ethyl acrylate) (PEA) grafts. The polymer-encapsulated cotton fibers were analyzed by Fourier transform infrared spectroscopy, scanning electron microscopy, differential scanning calorimetry (DSC), thermogravimetric analysis, and solid-state NMR (high-resolution 13C cross-polarization magic angle spinning, 1H spin-lattice relaxation times, and 1H free induction decay analysis NMR). The latter allowed the detection of the dynamic modifications associated with the presence of homo- and block copolymer grafts. In particular, the results of the DSC and NMR investigations suggest a heterogeneous morphology of the g-PEA-b-PSty grafted skin, which could be described as an inner layer of g-PEA sandwiched between the semicrystalline cellulose of the core fiber and the high glass transition temperature PSty of the covalently linked outer layer. Such morphology results in a reduced molecular mobility of the PEA chains.

  11. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  12. Chloroanthraquinone as a grafted probe molecule to investigate grafting yield on carbon powder

    International Nuclear Information System (INIS)

    Le Comte, Annaïg; Brousse, Thierry; Bélanger, Daniel

    2016-01-01

    Spontaneous grafting of chloroanthraquinone (ClAQ) groups on Black Pearls carbon by reduction of the corresponding in-situ generated diazonium cations was successfully achieved. The presence of an halogen atom on the quinone molecule allowed the use of different spectroscopic characterization techniques to determine the accurate quinone content of the modified carbon. Electrochemical characterization highlighted that the presence of chlorine atom on the grafted molecule did not affect the electrochemical response or the grafting reaction efficiency. The amount of ClAQ molecules at the carbon surface after grafting was determined by cyclic voltammetry, together with thermogravimetric analysis coupled mass spectroscopy, X-ray photoelectron spectroscopy and elemental analysis. The ClAQ mass loadings estimated from the four techniques are in very good agreement and confirm that the grafted moieties are all electrochemically active and accessible. Finally, the grafting of quinone-type molecule using the reduction of diazonium cations does not affect the electroactivity of the grafted groups and cyclic voltammetry can be considered as a reliable technique to evaluate the mass loading of grafted quinone groups on porous carbon. Thus ClAQ can be used as a grafted probe molecule to investigate grafting yield on carbon powder, and this approach can be extended to functionalized electrodes used in an increasing number of electrochemical energy storage devices.

  13. Synthesis of ion-exchange membranes by radiation-induced multiple grafting of methyl α,β,β-trifluoroacrylate

    International Nuclear Information System (INIS)

    Omichi, H.; Okamoto, J.

    1982-01-01

    Methyl α,β,β-trifluoroacrylate (MTFA) was grafted onto polymer films with the multiple grafting technique initiated by γ-rays: the yields were similar to those of the single-step grafting procedure with any irradiation dose. Grafted polymer obtained in the single-step experiments were distributed mainly near the film surface, whereas graft polymer from the multiple grafting experiments were distributed uniformly in the film at graft yields greater than 20%. The electric resistance of the hydrolyzed multiple graft polymer film in a 2N NaOH solution was much lower than that of one-step graft film at the same graft yield

  14. Grafting of acrylamide onto synthetic co polyamide by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamoud, M R; Qamhieyh, E A [Chemistry Dept., College of Ibn Al-Haitham Baghdad university-Adhamiyah-Baghdad- (Iraq)

    1995-10-01

    Grafted copolymer was prepared by using gamma irradiation to graft acrylamide onto polymeric molecule prepared by interfacial condensation between two diamine molecules like 1,2 diamino propane and 1,6 diamino-hexane in aqueous layer with sebacoyl chloride in organic layer. The resulted co polyamide was grafted with acrylamide using gamma irradiation. The optimum conditions of grafting reaction were found, also various factors such as the effect of solvents, redox systems and the role water on the radiochemical grafting were studied. Many techniques were used in the characterization of the copolymer before and after grafting. 8 figs.,.

  15. Characterization and Some Properties of Functionalized Graft Copolymer

    International Nuclear Information System (INIS)

    Hegazy El-Sayed, A.; Kamal, H.; Mahmoud, Gh.A.; Khalifa, N.A.

    2000-01-01

    The study involved the investigation and characterization of membranes prepared by graft copolymerization of acrylonitrile (AN) and vinyl acetate (VAc) binary monomers onto low density polyethylene (LDPE) and isotactic polypropylene (IPP). The mutual gamma-irradiation method was used as a grafting technique. The effects of grafting and chemical treatments on the thermal properties and crystallinity of prepared graft copolymer have been investigated using DSC, TGA and XRD. IR spectra recorded before and after grafting and also for the chemically treated membranes to elucidate the structural changes occurred due to grafting and chemical treatments

  16. Femoral Component Revision with Use of Impaction Bone-Grafting and a Cemented Polished Stem: A Concise Follow-up, at Fifteen to Twenty Years, of a Previous Report*

    NARCIS (Netherlands)

    Te Stroet, M.A.; Gardeniers, J.W.M.; Verdonschot, N.J.; Rijnen, W.H.C.; Slooff, T.J.J.H.; Schreurs, B.W.

    2012-01-01

    We previously reported our results for thirty-three consecutive femoral component revisions with impaction bone-grafting, performed with the X-change femoral revision system and a cemented polished Exeter stem, at a minimum of eight years of follow-up. The present updated study shows the results

  17. Impacts of Vocabulary Acquisition Techniques Instruction on Students' Learning

    Science.gov (United States)

    Orawiwatnakul, Wiwat

    2011-01-01

    The objectives of this study were to determine how the selected vocabulary acquisition techniques affected the vocabulary ability of 35 students who took EN 111 and investigate their attitudes towards the techniques instruction. The research study was one-group pretest and post-test design. The instruments employed were in-class exercises…

  18. The impact of business environment changes on recent costing techniques

    Institute of Scientific and Technical Information of China (English)

    林慧涓

    2011-01-01

    1.Introduction The acceleration of globalization and the prosperity of information technology benefit business a great deal.But with the speeding up of economic development,firms are facing more and more pressure from various aspects of their business.The heated debate is on about whether traditional management accounting practices and techniques are irrelevant to the current business environment and this essay will explore the causes for using some traditional management accounting practices and techniques in the current business environment are inappropriate and put forward some contemporary management accounting techniques which is relevant to the current business environment.Thus,the essay will be divided into three sections to discuss the traditional management accounting practices and techniques and contemporary management accounting techniques in current business environment.

  19. Accuracy of panoramic, panoramic with palpation and tube shift technique to localize maxillary impacted cuspid

    Directory of Open Access Journals (Sweden)

    GoodarziPour D.

    2009-12-01

    Full Text Available "nBackground and Aim: Impaction of maxillary cuspids is the most common after third molars with 1% to 3% prevalence. Localization of these impacted teeth may affect orthodontic or surgical treatment plan. Therefore, different techniques have been introduced to localize impacted canines. The present study was conducted to compare the accuracy of panoramic, tube shift and panoramic plus palpation in determination of the position of maxillary impacted canine."nMaterials and Methods: 47 patients (20 females, 27 males with the age of more than 12 years (mean age of 25.4 years old whom referred to Dental School, Tehran University of Medical Sciences, with at least one impacted maxillary canine included. An oral and maxillofacial radiologist localized impacted canine first by using panoramic then tube shift technique blindly. After that, an oral and maxillofacial surgeon localized the canine by panoramic and palpation of the area before surgery. Data obtained from radiologist and surgeon were compared with true location of canine after surgery. Statistical analysis was done using sensitivity and specificity."nResults: Among total 47 impacted maxillary canines, 11 cases (23.4% showed buccal impactions and 36 cases (76.6% palatal impactions. Sensitivity (ability of technique to localize palatal impaction of all of the techniques were same (100% but specificity (ability of technique to localize buccal impaction of tube shift (100% was more than two others (0%."nConclusion: The tube shift technique was the most accurate technique to localize maxillary unerupted canines compared to the others. Due to the ability of panoramic and panoramic with palpation in prediction of palatal canine impactions and failure of these techniques to predict buccal impactions, both methods are not suitable in localization of impacted maxillary canines and they must be used as adjunctive techniques.

  20. Measuring impact revisited - an update on infrastructure, methods and techniques

    CERN Multimedia

    CERN. Geneva

    2007-01-01

    Impact is generally defined as any change or outcome resulting from an activity. In case of scientific research publications are the quantifiable outcome of the research process. The presentation will therefore focus on electronic publication impact as a limited but rather well defined sub-field of research impact. Publication impact can be measured by author or reader generated indicators. Author generated indicators would be citations. Reader generated indicators would be usage. Usage data can be collected through webserver or linkresolver logs. It has to be normalized in order to be shared and analyzed meaningfully. There are some initiatives to provide a suitable infrastructure including publisher data (COUNTER/SUSHI) and data collected through open access repositories. Citation as well as usage data can be analyzed quantitatively or structurally. These analyses can be combined or complemented to create new metrics to add to the ISI impact factor (IF). View Frank Scholze's biography

  1. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  2. Simultaneous maxillary distraction osteogenesis using a twin-track distraction device combined with alveolar bone grafting in cleft patients: preliminary report of a technique.

    Science.gov (United States)

    Suzuki, Eduardo Yugo; Watanabe, Masayo; Buranastidporn, Boonsiva; Baba, Yoshiyuki; Ohyama, Kimie; Ishii, Masatoshi

    2006-01-01

    The simultaneous use of cleft reduction and maxillary advancement by distraction osteogenesis has not been applied routinely because of the difficulty in three-dimensional control and stabilization of the transported segments. This report describes a new approach of simultaneous bilateral alveolar cleft reduction and maxillary advancement by distraction osteogenesis combined with autogenous bone grafting. A custom-made Twin-Track device was used to allow bilateral alveolar cleft closure combined with simultaneous maxillary advancement, using distraction osteogenesis and a rigid external distraction system in a bilateral cleft lip and palate patient. After a maxillary Le Fort I osteotomy, autogenous iliac bone graft was placed in the cleft spaces before suturing. A latency period of six days was observed before activation. The rate of activation was one mm/d for the maxillary advancement and 0.5 mm/d for the segmental transport. Accordingly, the concave facial appearance was improved with acceptable occlusion, and complete bilateral cleft closure was attained. No adjustments were necessary to the vector of the transported segments during the activation and no complications were observed. The proposed Twin-Track device, based on the concept of track-guided bone transport, permitted three-dimensional control over the distraction processes allowing simultaneous cleft closure, maxillary distraction, and autogenous bone grafting. The combined simultaneous approach is extremely advantageous in correcting severe deformities, reducing the number of surgical interventions and, consequently, the total treatment time.

  3. History of free skin grafting. Knowledge of empiricism?

    OpenAIRE

    Klasen, Hendrik Jan

    1981-01-01

    In the course of more than a hundred years, skin grafting has become a standard procedure in surgery. The indications for the several types of grafting have become rather uniform.The technical aids at the operations only differ in details. Especially the vast experience gained in World War II provided the opportunity to develop the technique of skin grafting and so the evolution of present day plastics surgery. However, virtually every step in the field of indications, selection of grafts, te...

  4. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  5. A study on the morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method

    International Nuclear Information System (INIS)

    Song, Ju-Myung; Ko, Beom-Seok; Sohn, Joon-Yong; Nho, Young Chang; Shin, Junhwa

    2014-01-01

    The morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method was investigated using DMA, DSC, XRD, and SAXS instruments. The DMA study indicates that the ETFE amorphous phase and PS amorphous phase are mixed well in the PS-grafted ETFE films while the ETFE crystalline phase and the PS amorphous phase are separated, suggesting that the PS chains are grafted mainly on the ETFE amorphous regions. The DSC and XRD data showed that the natural crystalline structures of ETFE in the grafted ETFE films are not affected by the degree of grafting. The SAXS profiles displayed that the inter-crystalline distance of the ETFE films increases with an increasing degree of grafting, which further implies that the PS graft chains formed by the simultaneous irradiation has a significant impact on the amorphous morphology of the resulting grafted ETFE film. Thus, these results indicate that the styrene monomers are mainly grafted on the ETFE amorphous regions during the simultaneous radiation grafting process. - Highlights: • PS-grafted ETFE films were prepared by a simultaneous radiation grafting method was investigated. • The natural crystalline structures of grafted ETFE films are not affect by the degree of grafting. • The inter-crystalline distance of the ETFE films increase with increasing degree of grafting. • The styrene monomers are mainly grafted on the ETFE amorphous regions during a simultaneous radiation grafting using gamma-ray

  6. Long-term follow-up of treatment of erectile dysfunction after radical prostatectomy using nerve grafts and end-to-side somatic-autonomic neurorraphy: a new technique.

    Science.gov (United States)

    Souza Trindade, José Carlos; Viterbo, Fausto; Petean Trindade, André; Fávaro, Wagner José; Trindade-Filho, José Carlos Souza

    2017-06-01

    To study a novel penile reinnervation technique using four sural nerve grafts and end-to-side neurorraphies connecting bilaterally the femoral nerve and the cavernous corpus and the femoral nerve and the dorsal penile nerves. Ten patients (mean [± sd; range] age 60.3 [± 4.8; 54-68] years), who had undergone radical prostatectomy (RP) at least 2 years previously, underwent penile reinnervation in the present study. Four patients had undergone radiotherapy after RP. All patients reported satisfactory sexual activity prior to RP. The surgery involved bridging of the femoral nerve to the dorsal nerve of the penis and the inner part of the corpus cavernosum with sural nerve grafts and end-to-side neurorraphies. Patients were evaluated using the International Index of Erectile Function (IIEF) questionnaire and pharmaco-penile Doppler ultrasonography (PPDU) preoperatively and at 6, 12 and 18 months postoperatively, and using a Clinical Evolution of Erectile Function (CEEF) questionnaire, administered after 36 months. The IIEF scores showed improvements with regard to erectile dysfunction (ED), satisfaction with intercourse and general satisfaction. Evaluation of PPDU velocities did not reveal any difference between the right and left sides or among the different time points. The introduction of nerve grafts neither caused fibrosis of the corpus cavernosum, nor reduced penile vascular flow. CEEF results showed that sexual intercourse began after a mean of 13.7 months with frequency of sexual intercourse varying from once daily to once monthly. Acute complications were minimal. The study was limited by the small number of cases. A total of 60% of patients were able to achieve full penetration, on average, 13 months after reinnervation surgery. Patients previously submitted to radiotherapy had slower return of erectile function. We conclude that penile reinnervation surgery is a viable technique, with effective results, and could offer a new treatment method for ED after

  7. Radiobiological Impact of Planning Techniques for Prostate Cancer ...

    African Journals Online (AJOL)

    ... of RapidArc planning techniques for prostate cancer in terms of TCP and normal NTCP. Subjects and Methods: A computed tomography data set of ten cases involving low.risk prostate cancer was selected for this retrospective study. For each case, two RapidArc plans were created in Eclipse treatment planning system.

  8. Coronary artery bypass graft surgery--care globalization: the impact of national care on fatal and nonfatal outcome.

    Science.gov (United States)

    Ott, Elisabeth; Mazer, C David; Tudor, Iulia C; Shore-Lesserson, Linda; Snyder-Ramos, Stephanie A; Finegan, Barry A; Möhnle, Patrick; Hantler, Charles B; Böttiger, Bernd W; Latimer, Ray D; Browner, Warren S; Levin, Jack; Mangano, Dennis T

    2007-05-01

    In an international, prospective, observational study, we contrasted adverse vascular outcomes among four countries and then assessed practice pattern differences that may have contributed to these outcomes. A total of 5065 patients undergoing coronary artery bypass graft surgery were analyzed at 70 international medical centers, and from this pool, 3180 patients from the 4 highest enrolling countries were selected. Fatal and nonfatal postoperative ischemic complications related to the heart, brain, kidney, and gastrointestinal tract were assessed by blinded investigators. In-hospital mortality was 1.5% (9/619) in the United Kingdom, 2.0% (9/444) in Canada, 2.7% (34/1283) in the United States, and 3.8% (32/834) in Germany (P = .03). The rates of the composite outcome (morbidity and mortality) were 12% in the United Kingdom, 16% in Canada, 18% in the United States, and 24% in Germany (P < .001). After adjustment for difference in case-mix (using the European System for Cardiac Operative Risk Evaluation) and practice, country was not an independent predictor for mortality. However, there was an independent effect of country on composite outcome. The practices that were associated with adverse outcomes were the intraoperative use of aprotinin, intraoperative transfusion of fresh-frozen plasma or platelets, lack of use of early postoperative aspirin, and use of postoperative heparin. Significant between-country differences in perioperative outcome exist and appear to be related to hematologic practices, including administration of antifibrinolytics, fresh-frozen plasma, platelets, heparin, and aspirin. Understanding the mechanisms for these observations and selection of practices associated with improved outcomes may result in significant patient benefit.

  9. Less Is More: Results of a Statewide Analysis of the Impact of Blood Transfusion on Coronary Artery Bypass Grafting Outcomes.

    Science.gov (United States)

    Crawford, Todd C; Magruder, J Trent; Fraser, Charles; Suarez-Pierre, Alejandro; Alejo, Diane; Bobbitt, Jennifer; Fonner, Clifford E; Canner, Joseph K; Horvath, Keith; Wehberg, Kurt; Taylor, Bradley; Kwon, Christopher; Whitman, Glenn J; Conte, John V; Salenger, Rawn

    2018-01-01

    Debate persists over the association between blood transfusions, especially those considered discretionary, and outcomes after cardiac operations. Using data from the Maryland Cardiac Surgery Quality Initiative, we sought to determine whether outcomes differed among coronary artery bypass grafting (CABG) patients receiving 1 U of red blood cells (RBCs) vs none. We used a statewide database to review patients who underwent isolated CABG from July 1, 2011, to June 30, 2016, across 10 Maryland cardiac surgery centers. We included patients who received 1 U or fewer of RBCs from the time of the operation through discharge. Propensity scoring, using 20 variables to control for treatment effect, was performed among patients who did and did not receive a transfusion. These two groups were matched 1:1 to assess for differences in our primary outcomes: operative death, prolonged postoperative length of stay (>14 days), and a composite postoperative respiratory complication of pneumonia or reintubation, or both. Of 10,877 patients who underwent CABG, 6,124 (56%) received no RBCs (group 1) during their operative hospitalization, and 981 (9.0%) received 1 U of RBCs (group 2), including 345 of 981 patients (35%) who received a transfusion intraoperatively. Propensity score matching generated 937 well-matched pairs. Compared with group 2, propensity-matched analysis revealed significantly greater 30-day survival in group 1 (99% vs 98%, p = 0.02) and reduced incidence of prolonged length of stay (3.7% vs 4.0%, p < 0.01). Our collaborative statewide analysis demonstrated that even 1 unit of blood was associated with significantly worse survival and longer length of stay after CABG. Multiinstitutional quality initiatives may seek to address discretionary transfusions and possess the potential to improve patient outcomes. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. T-Helper Subsets Cytokine Production in Kidney Transplant Recipients: Diverting Influences and Impact on Graft Outcome

    Directory of Open Access Journals (Sweden)

    Hassan A

    2000-01-01

    Full Text Available A large body of evidence suggests the existence of functionally polarized human T-helper responses based on their profile of cytokine secretion. Human T-helper cell clones can be divided into two mutually exclusive subsets, T-helper cell 1 (Th1 and T-helper cell 2 (Th2. Substantial work in several animal models has demonstrated that allograft rejection is associated with enhanced Th1 activity and tolerance with enhanced Th2. Some studies have not been consistent with this association. In this study, gamma interferon (INF-y and interleukin 4 (IL-4 levels (as indicators of Th1 and Th2 activity, respectively were assayed in supernatant of cultured peripheral lymphocytes. The levels of these cytokines were compared between a study group of 26 stable kidney transplant recipients immunosuppressed with cyclosporine A, corticosteroids and azathioprine or mycophenolate mofetil, and a control group of 10 healthy blood donors. The mean INF-γ and IL-4 levels in the control group were considered as the cutoff levels for comparison. Our results showed that 25/26 of the study patients (96% had low levels of INF-γ compared to 4/10 of the control subjects (40%, (P< 0.05. However, the IL-4 level was high in 10/26 of the study patients (38% and 3/10 of the control subjects (30%, not a statistically significant difference, (P>0.05. In conclusion: These results suggest that well-established graft tolerance may be mediated via depressed Th1 activity rather than enhanced Th2 activity.

  11. Martial arts fall techniques decrease the impact forces at the hip during sideways falling.

    NARCIS (Netherlands)

    Groen, B.E.; Weerdesteijn, V.G.M.; Duysens, J.E.J.

    2007-01-01

    Falls to the side and those with impact on the hip are risky for hip fractures in the elderly. A previous study has indicated that martial arts (MA) fall techniques can reduce hip impact force, but the underlying mechanism is unknown. Furthermore, the high impact forces at the hand used to break the

  12. Quantitative impact of direct, personal feedback on hand hygiene technique.

    Science.gov (United States)

    Lehotsky, Á; Szilágyi, L; Ferenci, T; Kovács, L; Pethes, R; Wéber, G; Haidegger, T

    2015-09-01

    This study investigated the effectiveness of targeting hand hygiene technique using a new training device that provides objective, personal and quantitative feedback. One hundred and thirty-six healthcare workers in three Hungarian hospitals participated in a repetitive hand hygiene technique assessment study. Ultraviolet (UV)-labelled hand rub was used at each event, and digital images of the hands were subsequently taken under UV light. Immediate objective visual feedback was given to participants, showing missed areas on their hands. The rate of inadequate hand rubbing reduced from 50% to 15% (P < 0.001). However, maintenance of this reduced rate is likely to require continuous use of the electronic equipment. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Guided tooth eruption: Comparison of open and closed eruption techniques in labially impacted maxillary canines

    Directory of Open Access Journals (Sweden)

    S M londhe

    2014-01-01

    Full Text Available Background: After third molars, the maxillary canines are the most commonly impacted permanent teeth and one-third of these are labial impactions. Impacted canines often require orthodontic guidance in the eruption. This study was conducted to assess the posttreatment results of surgically exposed and orthodontically aligned labially impacted maxillary canines comparing two different surgical techniques. Materials and Methods: The study was conducted in two phases, a surgical phase and an orthodontic phase. In surgical phase, events during surgical exposure and recovery of 31 patients with labially impacted maxillary canine were recorded. Patients were managed with open and closed eruption technique. The assessment included comparison of two techniques of surgical exposure, postoperative pain, mobility, vitality, periodontal health, level of impaction, and duration of orthodontic treatment. Results: The postoperative recovery was longer after open eruption than close eruption technique (P = 0.000. Postoperative pain experienced by patients was similar, but regression of pain was faster in closed eruption technique. The mean surgical time for open eruption technique was lesser when compared with closed eruption technique (P = 0.000. The total duration of orthodontic treatment was directly dependent upon the level of impaction, with deeper level of impaction having longer duration of orthodontic treatment. The mobility and vitality of guided canine was similar in both techniques. Conclusion: The closed eruption technique was a longer surgical procedure, but the postoperative pain regression was faster. The duration of orthodontic treatment was longer with deeper level of impaction. The closed eruption surgical techniques provide better periodontal tissues around the guided erupted teeth.

  14. Vacuum ultraviolet spectroscopy of some hydrocarbons by electron impact technique

    International Nuclear Information System (INIS)

    Azevedo e Souza, A.C. de.

    1985-07-01

    A detailed description of the construction and operation of the electron impact spectrometer of the Electron Impact Laboratory at the Chemistry Institute of Federal University of Rio de Janeiro are presented. The main characteristics of this spectrometer are: incident energy from 0.5 to 3.0 KeV; angular range from -60 0 to + 60 0 ; energy loss from 0 to 500 eV; energy resolution from 0.5 to 2.5 eV and; electron velocity analyser equal to electrostatic (Mollenstedt type. The data acquisition system is based on a microcomputer Motorola; recently an APPLE II system has been incorporated to the spectrometer. Electron energy loss spectra for the nitrogen molecule as well as for some hydrocarbons (C 2 H 6 , C 2 H 4 , C 2 H 2 ) have been obtained. The data were converted into double differential cross sections and generalized oscillator strenghts. (author) [pt

  15. The influence of organizational culture on the use of quality techniques and its impact on performance

    DEFF Research Database (Denmark)

    Gambi, Lillian; Jørgensen, Frances; Boer, Harry

    2013-01-01

    This report presents the results of a study about the influence of organizational culture on quality techniques and the impact of matching culture and technique to enhance performance. Data were drawn from 250 manufacturing companies in Brazil and Denmark. Profiles were identified according....... 2- Quality techniques contribute to improve performance, provided they are supported by appropriate cultural characteristics. For instance, the use of goal setting, continuous improvement, and failure prevention and control techniques supported by group and developmental cultures contribute...

  16. Radiation-induced grafting of acrylamide onto guar gum in aqueous medium: Synthesis and characterization of grafted polymer guar-g-acrylamide

    Energy Technology Data Exchange (ETDEWEB)

    Biswal, Jayashree [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Kumar, Virendra [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Bhardwaj, Y.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)]. E-mail: ykbhard@magnum.barc.ernet.in; Goel, N.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Dubey, K.A. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Chaudhari, C.V. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Sabharwal, S. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2007-10-15

    Mutual radiation grafting technique has been applied to carry out grafting of acrylamide (AAm) onto guar gum (GG) using high-energy Co{sup 60} {gamma} radiation to enhance its flocculating properties for industrial effluents. The grafted product was characterized using analytical probes like elemental analysis, thermal analysis, Fourier transformed infrared (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). The grafting extent was observed to decrease with the dose rate and increase with the concentration of AAm. Thermo gravimetric analysis (TGA) of grafted and ungrafted samples indicated better stability of grafted product. {gamma} and microwave radiation effect on grafted and virgin GG has also been reported.

  17. Radiation-induced grafting from binary mixture of monomers onto cellulose acetate film and the characterization of the graft copolymer

    International Nuclear Information System (INIS)

    Bhattacharyya, S.N.; Maldas, D.

    1984-01-01

    Binary mixtures of styrene and acrylamide in methanol-water were grafted onto cellulose acetate films by taking recourse to preirradiation grafting technique. The extent of total grafting was determined from the measured weight increase. The percent acrylamide residue in the graft copolymer was calculated from the observed nitrogen content but the polystyrene residue in the grafted sample was determined by IR spectral studies. When the specific permeability of water vapour through the grafted films is measured, it is observed that the specific permeability increases with the increase of grafting of acrylamide in all humidities, but in case of styrene which is a nonpolar molecule the permeability is found to show a reversed order. In the case of mixed graft the permeability pattern pertains to that when both styrene and acrylamide have their effective roles to play. (author)

  18. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  19. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  20. The caudal septum replacement graft.

    Science.gov (United States)

    Foda, Hossam M T

    2008-01-01

    To describe a technique for reconstructing the lost tip support in cases involving caudal septal and premaxillary deficiencies. The study included 120 patients with aesthetic and functional nasal problems resulting from the loss of caudal septal and premaxillary support. An external rhinoplasty approach was performed to reconstruct the lost support using a cartilaginous caudal septum replacement graft and premaxillary augmentation with Mersilene mesh. The majority of cases (75%) involved revisions in patients who had previously undergone 1 or more nasal surgical procedures. A caudal septum replacement graft was combined with premaxillary augmentation in 93 patients (77.5%). The mean follow-up period was 3 years (range, 1-12 years). The technique succeeded in correcting the external nasal deformities in all patients and resulted in a significant improvement in breathing in 74 patients (86%) with preoperative nasal obstruction. There were no cases of infection, displacement, or extrusion. The caudal septum replacement graft proved to be very effective in restoring the lost tip support in patients with caudal septal deficiency. Combining the graft with premaxillary augmentation using Mersilene mesh helped increase support and stability over long-term follow-up.

  1. Environmental impact statements: new legal technique for environmental protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, M F

    1975-02-01

    The National Environmental Policy Act (NEPA) has required Federal agencies to re-examine all their programs affecting the environment, to consider alternative policies, to coordinate their actions with other agencies, and to disclose their environmental analyses to the public. In short, it has attempted to change decision processes markedly, in order to respond to wide-spread public concern about a deteriorating natural and human environment. The mandates of the policy are listed, but knowing that these were not sufficient to change existing agency practices, Congress established what has been called an ''action-forcing mechanism.'' Each federal agency must ''include in every recommendation or report on proposals for legislation and other major federal actions significantly affecting the quality of the human environment, a detailed statement by the responsible official.'' This statement must cover the following five points as specified in Section 102(2)(c): the environmental impact of the proposed action; any adverse environmental effects which cannot be avoided should the proposal be implemented; alternatives to the proposed action; the relationship between local and short-term uses of man's environment and the maintenance and enhancement of long-term productivity, and any irreversible and irretrievable commitments of resources which would be involved in the proposed action should it be implemented. Section 102 has been considered the heart of the National Environmental Policy Act. The specific five-point environmental report--known as an environmental impact statement--is the visible evidence of an agency's compliance with the environmental policy articulated by Congress. (MCW)

  2. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  3. Interaction techniques for radiology workstations: impact on users' productivity

    Science.gov (United States)

    Moise, Adrian; Atkins, M. Stella

    2004-04-01

    As radiologists progress from reading images presented on film to modern computer systems with images presented on high-resolution displays, many new problems arise. Although the digital medium has many advantages, the radiologist"s job becomes cluttered with many new tasks related to image manipulation. This paper presents our solution for supporting radiologists" interpretation of digital images by automating image presentation during sequential interpretation steps. Our method supports scenario based interpretation, which group data temporally, according to the mental paradigm of the physician. We extended current hanging protocols with support for "stages". A stage reflects the presentation of digital information required to complete a single step within a complex task. We demonstrated the benefits of staging in a user study with 20 lay subjects involved in a visual conjunctive search for targets, similar to a radiology task of identifying anatomical abnormalities. We designed a task and a set of stimuli which allowed us to simulate the interpretation workflow from a typical radiology scenario - reading a chest computed radiography exam when a prior study is also available. The simulation was possible by abstracting the radiologist"s task and the basic workstation navigation functionality. We introduced "Stages," an interaction technique attuned to the radiologist"s interpretation task. Compared to the traditional user interface, Stages generated a 14% reduction in the average interpretation.

  4. Impact of screwworm eradication programmes using the sterile insect technique

    International Nuclear Information System (INIS)

    Vargas-Teran, M.; Hofmann, H.C.; Tweddle, N.E.

    2005-01-01

    The use of the sterile insect technique (SIT) in New World screwworm Cochliomyia hominivorax (Coquerel) eradication programmes has been successfully demonstrated. As a result of a 45-year area-wide campaign, suppression and eradication have been achieved in the USA, Mexico, Belize, Guatemala, Honduras, El Salvador, Nicaragua, Costa Rica, Panama north of the Canal, some Caribbean Islands, and the outbreak in Libya, North Africa. The humans, livestock, and wildlife in these countries are now free of this dangerous pest. It has been estimated that the annual producer benefits are: USA - USD 796 million, Mexico - USD 292 million, and Central America - USD 77.9 million. In Libya, the estimated benefit/cost ratio was 5:1 in the infested zone, and 10:1 in the whole country. If the New World screwworm were eradicated in South America, it has been estimated that each year USD 3592 million could be saved. Small field trials have confirmed that the SIT would be effective for the area-wide control of the Old World screwworm Chrysomya bezziana (Villeneuve). (author)

  5. GPR as a Low Impact Paleontogical Survey Technique

    Science.gov (United States)

    Sturdevant, G. C.; Leverence, R.; Stewart, R.

    2013-12-01

    The Deweyville Formation, a Pleistocene fluvial sandstone, is a prolific source of megafaunal fossils from periods of low stand environmental conditions. GPR was employed in an environmentally sensitive area in close proximity to a salt dome in Northwest Harris County, Texas as a method of evaluating the probable paleo-depositional environment and to prospect for potential further site development of two distinct fossiliferous zones. The primary zone of interest is a lag gravel bounded sand responsible for producing a regionally unique fossil assemblage including South American megafauna (Lundelius et al, 2013). The secondary zone of interest contains undisturbed mammoth remains housed in coarse white sand emplaced on top of a clay drape which has been hypothesized to represent an oxbow lake formed by the meandering paleo-Brazos river. With an accurate map of the paleo-channel planning future activity can focus on maximizing fossil recovery and minimizing site impact. Pulse EKKO 250 MHz, 400MHz, and 1GHz system was employed in a prospect area proximal to the secondary site to calibrate and evaluate these systems for their resolution and penetration depth in the modern sediments. The data was processed using EKKO Mapper and EKKO View Deluxe software packages, 3d volumes were produced and sliced. Preliminary results from the 250 MHz demonstrate successful imaging of the sand-clay interface. After these surveys were run a small portion of the site was excavated to confirm the estimated velocities, the observed anomalies, and refine our modeling and interpretation, and improve grid design for further surveys. It was confirmed that the sand-clay interface was easily observable using GPR, however the grid spacing proved to be too wide, leading to artifacts in the 3d volume produced.

  6. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery.

    Directory of Open Access Journals (Sweden)

    Gulinu Maimaituxun

    Full Text Available Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV in patients undergoing coronary artery bypass grafting (CABG remains unknown.Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57 who underwent CABG or non-coronary valvular surgery (non-CABG.In men, EATV, EATV index (EATV/body surface area and the markers of adiposity such as body mass index, waist circumference and visceral fat area were higher in the CABG group than in the non-CABG group. Traditional ASCVD risk factors were also prevalent in the CABG group. In women, EATV and EATV index were higher in the CABG group, but other adiposity markers were comparable between CABG and non-CABG groups. Multivariate logistic regression analysis showed that in men, CABG was determined by EATV Index and other ASCVD risk factors including hypertension, dyslipidemia, adiponectin, high sensitive C-reactive protein (hsCRP and type 2 diabetes mellitus (Corrected R2 = 0.262, p < 0.0001, while in women, type 2 diabetes mellitus is a single strong predictor for CABG, excluding EATV Index (Corrected R2 = 0.266, p = 0.005.Our study found that multiple risk factors, including epicardial adipose tissue volume and traditional ASCVD factors are determinants for CABG in men, but type 2 diabetes mellitus was the sole determinant in women. Gender-specific disparities in risk factors of CABG prompt us to evaluate new diagnostic and treatment strategies and to seek underlying mechanisms.

  7. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery.

    Science.gov (United States)

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro; Sata, Masataka

    2017-01-01

    Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery (non-CABG). In men, EATV, EATV index (EATV/body surface area) and the markers of adiposity such as body mass index, waist circumference and visceral fat area were higher in the CABG group than in the non-CABG group. Traditional ASCVD risk factors were also prevalent in the CABG group. In women, EATV and EATV index were higher in the CABG group, but other adiposity markers were comparable between CABG and non-CABG groups. Multivariate logistic regression analysis showed that in men, CABG was determined by EATV Index and other ASCVD risk factors including hypertension, dyslipidemia, adiponectin, high sensitive C-reactive protein (hsCRP) and type 2 diabetes mellitus (Corrected R2 = 0.262, p EATV Index (Corrected R2 = 0.266, p = 0.005). Our study found that multiple risk factors, including epicardial adipose tissue volume and traditional ASCVD factors are determinants for CABG in men, but type 2 diabetes mellitus was the sole determinant in women. Gender-specific disparities in risk factors of CABG prompt us to evaluate new diagnostic and treatment strategies and to seek underlying mechanisms.

  8. Pediatric burn wound impetigo after grafting.

    Science.gov (United States)

    Aikins, Kimberly; Prasad, Narayan; Menon, Seema; Harvey, John G; Holland, Andrew J A

    2015-01-01

    Modern burn care techniques have reduced the risk of infection of the acute burn wound, resulting in more rapid healing and a lower incidence of graft loss. Secondary breakdown may still occur. The loss of epithelium in association with multifocal superficial abscesses and ulceration has been termed burns impetigo. This may result in considerable morbidity and require prolonged treatment. The events preceding development, the impact on the patient, and the ideal treatment appear unclear and poorly reported. In 5 years, between 2006 and 2011, 406 pediatric burns were treated with skin grafts, with 7% developing burns impetigo. Time to resolution ranged from 5 to 241 days: the mean time to complete healing was greatest with conservative management (96 days), followed by antibacterial dressings (37 days), oral antibiotics (36 days), topical steroids (16 days), and oral antibiotics in combination with topical steroids (13.5 days). Burns impetigo resulted in significant morbidity, requiring multiple visits to the treatment center and prolonged symptoms. Delay in diagnosis and treatment resulted in worse outcomes. Prompt consideration of burns impetigo should occur when postgraft patients present with suggestive clinical signs and treatment with oral antibiotics plus topical steroids should be considered.

  9. Assessment of the impact strength of the denture base resin polymerized by various processing techniques

    Directory of Open Access Journals (Sweden)

    Rajashree Jadhav

    2013-01-01

    Full Text Available Aim : To measure the impact strength of denture base resins polymerized using short and long curing cycles by water bath, pressure cooker and microwave techniques. Materials and Methods: For impact strength testing, 60 samples were made. The sample dimensions were 60 mm × 12 mm × 3 mm, as standardized by the American Standards for Testing and Materials (ASTM. A digital caliper was used to locate the midpoint of sample. The impact strength was measured in IZOD type of impact tester using CEAST Impact tester. The pendulum struck the sample and it broke. The energy required to break the sample was measured in Joules. Data were analyzed using Student′s " t" test. Results: There was statistically significant difference in the impact strength of denture base resins polymerized by long curing cycle and short curing cycle in each technique, with the long curing processing being the best. Conclusion: The polymerization technique plays an important role in the influence of impact strength in the denture base resin. This research demonstrates that the denture base resin polymerized by microwave processing technique possessed the highest impact strength.

  10. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain : Impact on respiratory muscle function, activity, mood and exercise capacity

    OpenAIRE

    會田, 信子; 渋谷, 優子; 吉野, 克樹; Komoda, Masaji; 井上, 智子

    2002-01-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) g...

  11. Nature or Artifice? Grafting in Early Modern Surgery and Agronomy.

    Science.gov (United States)

    Savoia, Paolo

    2017-01-01

    In 1597, Gaspare Tagliacozzi published a famous two-volume book on “plastic surgery.” The reconstructive technique he described was based on grafting skin taken from the arm onto the mutilated parts of the patient's damaged face – especially noses. This paper focuses on techniques of grafting, the “culture of grafting,” and the relationships between surgery and plant sciences in the sixteenth century. By describing the fascination with grafting in surgery, natural history, gardening, and agronomy the paper argues that grafting techniques were subject to delicate issues: to what extent it was morally acceptable to deceive the eye with artificial entities? and what was the status of the product of a surgical procedure that challenged the traditional natural/artificial distinction? Finally, this paper shows how in the seventeenth century grafting survived the crisis of Galenism by discussing the role it played in teratology and in controversies on the uses the new mechanistic anatomy.

  12. Effect of solubility parameter of solvents on electron beam induced graft-polymerization onto polyethylene films

    International Nuclear Information System (INIS)

    Mori, Koji; Koshiishi, Kenji; Masuhara, Ken-ichi

    1992-01-01

    Electron beam induced graft-polymerization by the mutual irradiation technique of methyl methacrylate (MMA) and methacrylic acid (MAAc) blended with solvents, which have different solubility parameters δ, onto high density polyethylene films (PE) were investigated at high dose rates (25 Mrad per second). Graft-polymerization mechanisms were discussed on the basis of grafting rates, surface tensions, atomic rations on the surface by XPS, and SEM images of the grafted films. Grafting rates decreased with increasing δ of solvents, and grafting rates for MMA were larger than those for MAAc. Graft chain contents on the surface, which were evaluated in terms of surface tensions and atomic ratios on the surface, increased with increasing δ of solvents, and graft chain contents on the surface of MAAc grafted PE were higher than those of MMA grafted PE. It is assumed that mutual solubility of PE and solvents (monomer solutions), i.e., infiltration of monomer solutions into PE during graft-polymerization, influenced grafting rates and graft sites in films. In case of high mutual solubility, grafting rates were large and graft sites spread from the surface into bulk. On the other hand, in case of low mutual solubility, grafting rates were small and graft sites localized on the surface of films. (author)

  13. [Autologous fat grafting in children].

    Science.gov (United States)

    Baptista, C; Bertrand, B; Philandrianos, C; Degardin, N; Casanova, D

    2016-10-01

    Lipofilling or fat grafting transfer is defined as a technique of filling soft tissue by autologous fat grafting. The basic principle of lipofilling is based on a harvest of adipose tissue, followed by a reinjection after treatment. Lipofilling main objective is a volume defect filling, but also improving cutaneous trophicity. Lipofilling specificities among children is mainly based on these indications. Complications of autologous fat grafting among children are the same as those in adults: we distinguish short-term complications (intraoperative and perioperative) and the medium and long-term complications. The harvesting of fat tissue is the main limiting factor of the technique, due to low percentage of body fat of children. Indications of lipofilling among children may be specific or similar to those in adults. There are two types of indications: cosmetic, in which the aim of lipofilling is correcting a defect density, acquired (iatrogenic, post-traumatic scar) or malformation (otomandibular dysplasia, craniosynostosis, Parry Romberg syndrom, Poland syndrom, pectus excavatum…). The aim of functional indications is correcting a velar insufficiency or lagophthalmos. In the paediatric sector, lipofilling has become an alternative to the conventional techniques, by its reliability, safety, reproducibility, and good results. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  15. Application of fisheries management techniques to assessing impacts: task I report

    International Nuclear Information System (INIS)

    McKenzie, D.H.; Baker, K.S.; Fickeisen, D.H.; Metzger, R.M.; Skalski, J.R.

    1979-03-01

    Task I efforts examined the available fisheries management techniques and assessed their potential application in a confirmatory monitoring program. The objective of such monitoring programs is to confirm that the prediction of an insignificant impact (usually made in the FES) was correct. Fisheries resource managers have developed several tools for assessing the fish population response to stress (exploitation) and they were thought potentially useful for detecting nuclear power plant impacts. Techniques in three categories were examined; catch removal, population dynamics, and nondestructive censuses, and the report contains their description, examples of application, advantages, and disadvantages. The techniques applied at nuclear power plant sites were examined in detail to provide information on implementation and variability of specific approaches. The most suitable techniques to incorporate into a monitoring program confirming no impact appear to be those based on Catch Per Unity Effort (CPUE) and hydroacoustic data. In some specific cases, age and growth studies and indirect census techniques may be beneficial. Recommendations for task II efforts to incorporate these techniques into monitoring program designs are presented. These include development of guidelines for; (1) designing and implementing a data collection program; (2) interpreting these data and assessing the occurrence of impact, and (3) establishment of the monitoring program's ability to detect changes in the affected populations

  16. The effect of the descent technique and truck cabin layout on the landing impact forces.

    Science.gov (United States)

    Patenaude, S; Marchand, D; Samperi, S; Bélanger, M

    2001-12-01

    The majority of injuries to truckers are caused by falls during the descent from the cab of the truck. Several studies have shown that the techniques used to descend from the truck and the layout of the truck's cabin are the principal cause of injury. The goal of the present study was to measure the effects of the descent techniques used by the trucker and the layout of the truck's cabin on the impact forces absorbed by the lower limbs and the back. Kinematic data, obtained with the aid of a video camera, were combined with the force platform data to allow for calculation of the lower limb and L5-S1 torques as well as L5-S1 compressive forces. The trucker descended from two different conventional tractor cabin layouts. Each trucker descended from cabin using either "facing the truck" (FT) or "back to the truck" (BT) techniques. The results demonstrate that the BT technique produces greater ground impact forces than the FT technique, particularly when the truck does not have a handrail. The BT technique also causes an increase in the compressive forces exerted on the back. In conclusion, the use of the FT technique along with the aids (i.e., handrails and all the steps) help lower the landing impact forces as well as the lumbosacral compressive forces.

  17. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    Science.gov (United States)

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  18. Insolubilisation of biologically active materials with novel radiation graft copolymers

    International Nuclear Information System (INIS)

    Garnett, J.L.; Jankiewicz, S.V.; Levot, R.; Sangster, D.F.

    1984-01-01

    The use of radiation grafting to immobilise a typical enzyme, trypsin, is reported. The technique involves radiation grafting to a backbone polymer a monomer containing an appropriate functional group to which the enzyme is bonded. In the present work, p-nitrostyrene has been grafted to representative trunk polymers, polypropylene and PVC, the nitro group in the resulting copolymer converted to the isothiocyanato derivative to which trypsin is attached. Of importance to this insolubilisation process, especially for radiation sensitive backbone polymers, is the inclusion of additives which enhance grafting. A new class of additives which increase the grafting yields is reported using as representative backbone polymers, naturally occurring cellulose and synthetic low density polyethylene. The new additives are specific metal salts such as LiClO 4 . The reactivity of these salts in grafting enhancement has been compared with that of mineral acid which has previously been used as an additive to increase grafting yields in both preirradiation and simultaneous techniques. A new model for grafting enhancement in the presence of the metal salts as well as acids is proposed whereby increased grafting yields are attributed to increased partitioning of monomer into the graft region in the presence of ionic solutes. The value of these additives in preparing copolymers suitable for general reagent insolubilisation reactions is discussed

  19. The impact of applying product-modelling techniques in configurator projects

    DEFF Research Database (Denmark)

    Hvam, Lars; Kristjansdottir, Katrin; Shafiee, Sara

    2018-01-01

    This paper aims to increase understanding of the impact of using product-modelling techniques to structure and formalise knowledge in configurator projects. Companies that provide customised products increasingly apply configurators in support of sales and design activities, reaping benefits...... that include shorter lead times, improved quality of specifications and products, and lower overall product costs. The design and implementation of configurators are a challenging task that calls for scientifically based modelling techniques to support the formal representation of configurator knowledge. Even...... the phenomenon model and information model are considered visually, (2) non-UML-based modelling techniques, in which only the phenomenon model is considered and (3) non-formal modelling techniques. This study analyses the impact to companies from increased availability of product knowledge and improved control...

  20. Speech Impact Realization via Manipulative Argumentation Techniques in Modern American Political Discourse

    OpenAIRE

    Zarine Avetisyan

    2015-01-01

    The present paper presents the discussion of scholars concerning speech impact, peculiarities of its realization, speech strategies and techniques in particular. Departing from the viewpoints of many prominent linguists, the paper suggests that manipulative argumentation be viewed as a most pervasive speech strategy with a certain set of techniques which are to be found in modern American political discourse. The precedence of their occurrence allows us to regard them as ...

  1. Synthesis of Radiation Grafted Polymer Matrices for Separation and Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhardwaj, Y K; Virendra, K; Goel, N K; Sarma, K S.S.; Sabharwal, S [Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2012-09-15

    Grafting of acrylonitrile onto non-woven porous polypropylene fibre sheet using electron beam was carried out by post-irradiation grafting. Grafting extent of {approx}125% was achieved. The grafted nitrile groups were amidoximated and studied for uranium uptake from sea water and heavy metal ions (Co{sup 2+}, Ni{sup 2+}, Mn{sup 2+}, and Cd{sup 2+}) from aqueous solutions. Adsorption and elution of adsorbed ions in suitable eluents was studied. The grafting process was upgraded to pilot scale to obtain 1x1 m{sup 2} sheets. Mutual radiation grafting technique was used for grafting of vinylbenzyltrimethyl ammonium chloride, [2- (methacryloyloxy)ethyl] trimethylammonium chloride and [2-(acryloyloxyethyl)]trimethylammonium chloride onto cotton cellulose substrate. The grafted matrices showed significantly higher water uptake and good water retention properties. The antibacterial efficacy of the grafted products was found to be a function of extent of grafting and the type of bacteria (Escherichia coli, Pseudomonas flourescens, Staphylococcus aureus and Bacillus cereus). PVBT-g-cotton was studied for its protein adsorption behaviour in continuous column process using Bovine serum albumin (BSA) as a model protein. Mutual radiation grafting technique was used to graft acrylic acid on micrometer thick micro-porous polypropylene membrane. Contact angle measurement studies showed that initial grafting as well as radiation treatment of poly(propylene) in aqueous medium and in presence of Mohr's salt enhances its affinity towards the grafting solution. The enhancement in the polar component of surface energy of treated polypropylene membrane is the primary cause of grafting enhancement. The membranes grafted to an extent of {approx}20% were found to perform comparably with the battery separator presently being used by battery industry. Acrylic acid was grafted to Teflon scrap by mutual radiation grafting technique. The grafting extent decreased with increasing dose rate and

  2. Septal graft in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Bahannan, Abdulrahman; Slavicek, A.; Taudy, M.; Chovanec, M.

    2006-01-01

    A 62-year-old woman presented with symptoms of dyspnea. Ultrasonography and computed tomography examinations revealed mass extending from the cricoid cartilage to the left lobe of thyroid gland and thyroid cartilage. Cytology revealed possibility of cartilaginous origin, which was proven to be chondrosarcoma (Grade 1) from the biopsy specimen obtained during panendosopy. She underwent one stage radical resection and immediate reconstruction of laryngeal skeleton defect by mucocartilaginous graft from the nasal septum. Her postoperative course was optimal with preservation of the laryngeal functions. Twenty-eight months postoperatively, she had to undergo total laryngectomy as a salvage procedure for the advanced local recurrence. We report on the relatively easy technique for functional reconstruction of the large laryngeal defect with the employment cartilage graft from the nasal septum. (author)

  3. Clinical application of human adipose tissue-derived mesenchymal stem cells in progressive hemifacial atrophy (Parry-Romberg disease) with microfat grafting techniques using 3-dimensional computed tomography and 3-dimensional camera.

    Science.gov (United States)

    Koh, Kyung Suk; Oh, Tae Suk; Kim, Hoon; Chung, In Wook; Lee, Kang Woo; Lee, Hyo Bo; Park, Eun Jung; Jung, Jae Seob; Shin, Il Seob; Ra, Jeong Chan; Choi, Jong Woo

    2012-09-01

    Parry-Romberg disease is a rare condition that results in progressive hemifacial atrophy, involving the skin, dermis, subcutaneous fat, muscle, and, finally, cartilage and bone. Patients have been treated with dermofat or fat grafts or by microvascular free flap transfer. We hypothesized that adipose-derived stem cells (ASCs) may improve the results of microfat grafting through enhancing angiogenesis. We evaluated the utility of ASC in microfat grafting of patients with Parry-Romberg disease by measuring the change in the hemifacial volumes after injection of ASCs with microfat grafts or microfat grafts alone. In April 2008, this investigation was approved by the Korean Food and Drug Administration and the institutional review board of the Asan Medical Center (Seoul, Korea) that monitor investigator-initiated trials. Between May 2008 and January 2009, 10 volunteers with Parry-Romberg disease (5 men and 5 women; mean age, 28 y) were recruited; 5 received ASC and microfat grafts and 5 received microfat grafts only. The mean follow-up period was 15 months. Adipose-derived stem cells were obtained from abdominal fat by liposuction and were cultured for 2 weeks. On day 14, patients were injected with fat grafts alone or plus (in the test group) 1 × 10 ASCs. Patients were evaluated postoperatively using a 3-dimensional camera and 3-dimensional CT scans, and grafted fat volumes were objectively calculated. Successful outcomes were evident in all 5 patients receiving microfat grafts and ASCs, and the survival of grafted fat was better than in patients receiving microfat grafts alone. Before surgery, the mean difference between ipsilateral and contralateral hemiface volume in patients receiving microfat grafts and ASCs was 21.71 mL decreasing to 4.47 mL after surgery. Overall resorption in this ASC group was 20.59%. The mean preoperative difference in hemiface volume in those receiving microfat grafts alone was 8.32 mL decreasing to 3.89 mL after surgery. Overall

  4. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  5. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  6. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  7. Prospective electrocardiogram-gated axial 64-detector computed tomographic angiography vs retrospective gated helical technique to assess coronary artery bypass graft anastomosis. Comparison of image quality and patient radiation dose

    International Nuclear Information System (INIS)

    Machida, Haruhiko; Masukawa, Ai; Tanaka, Isao; Fukui, Rika; Suzuki, Kazufumi; Ueno, Eiko; Kodera, Kojiro; Nakano, Kiyoharu; Shen, Y.

    2010-01-01

    In the present study the effective dose and image quality at distal anastomoses were retrospectively compared between prospective electrocardiogram (ECG)-gated axial and retrospective ECG-gated helical techniques on 64-detector computed tomographic (CT) angiography following coronary artery bypass graft surgery. Following bypass surgery, 52 patients with a heart rate <65 beats/min underwent CT angiography: 26 patients each with prospective and retrospective ECG gating techniques. The effective dose was compared between the 2 groups using a 4-point scale (4, excellent; 1, poor) to grade the quality of curved multiplanar reformation images at distal anastomoses. Patient characteristics of the 2 groups were well matched, and the same CT scan parameters were used for both, except for the interval between surgery and CT examination, tube current, and image noise index. Image quality scores did not differ significantly (3.26±0.95 vs 3.35±0.87; P=0.63), but the effective dose was significantly lower in the prospective (7.3±1.8 mSv) than in the retrospective gating group (23.6±4.5 mSv) (P<0.0001). Following bypass surgery, 64-detector CT angiography using prospective ECG gating is superior to retrospective gating in limiting the radiation dose and maintaining the image quality of distal anastomoses. (author)

  8. Root coverage with connective tissue graft associated with coronally advanced flap or tunnel technique: a randomized, double-blind, mono-centre clinical trial

    NARCIS (Netherlands)

    Azaripour, Adriano; Kissinger, Maren; Farina, Vittorio Siro Leone; van Noorden, Cornelis J. F.; Gerhold-Ay, Aslihan; Willershausen, Brita; Cortellini, Pierpaolo

    2016-01-01

    Aim: The aim of this randomized clinical trial was to compare the coronally advanced flap (CAF) with the modified microsurgical tunnel technique (MMTT) for treatment of Miller class I and II recessions. Material and Methods: Forty patients with 71 gingival recessions were recruited and randomly

  9. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  10. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  11. Adherence in patients in the first year after kidney transplantation and its impact on graft loss and mortality : a cross-sectional and prospective study

    NARCIS (Netherlands)

    Prihodova, Lucia; Nagyova, Iveta; Rosenberger, Jaroslav; Majernikova, Maria; Roland, Robert; Groothoff, Johan W.; van Dijk, Jitse P.

    2014-01-01

    Aims. To explore the predictive value of adherence to their immunosuppressive medication in kidney transplant recipients in the first year after kidney transplantation as a determinant of graft loss and mortality up to 12 years (prospective analysis) and its association with sociodemographic and

  12. Modification of polyetherurethane for biomedical application by radiation-induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1985-01-01

    Radiation grafting of monomers onto suitable trunk polymers is a useful tool for tailoring new polymers for special purposes. This technique has been used in the past for the development of biocompatible materials, e.g., by grafting hydrogels onto mechanically stable polymers. In this first part of our work, the radiation grafting of hydrophilic or reactive monomers onto a polyetherurethane film using the pre-swelling technique is described. Following this technique the trunk polymer was swollen in the monomer before irradiation. As monomers 2-hydroxyethyl methacrylate (HEMA), 2,3-epoxypropyl methacrylate (GMA), 2,3-dihydroxypropyl methacrylate (GOMA), and acrylamide (AAm) were used. The kinetics of the grafting reactions were examined, and the distribution of the graft component inside the trunk polymer was investigated by means of infrared (IR) spectroscopy. Surface-grafted as well as bulk- and surface-grafted products could be obtained. The mechanical behavior of the grafted films--especially in the water-swollen state--was examined and compared with that of the pure trunk polymer. In nearly all cases it was found that the tensile strength sigma B and the elongation at break epsilon R decreases as the grafting yield increases. Modification of GMA- and AAm-grafted films via chemical reactions was performed to create new functional groups of biomedical interest. In this manner a diol structure, a carboxylic acid structure, and a sulfonic acid group could be introduced in the grafted polymer. The water uptake of such modified films is increased markedly when compared with that of the unmodified samples

  13. Comparative study of two autogenous graft techniques using piezosurgery for sinus lifting Estudo comparativo de duas técnicas de enxerto autógeno utilizando piezocirurgia para levantamento de seio maxilar

    Directory of Open Access Journals (Sweden)

    Geraldo Prestes de Camargo Filho

    2010-12-01

    Full Text Available PURPOSE: Maxillary sinus lifting is a technique, in which, a possible complication is sinus membrane perforation. The aim of this study was to compare two techniques using ultrasound surgery to perform autogenous graft for maxillary sinus lifting. METHODS: Ten rabbits were used in the study, one of them did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side, and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were statistically compared. RESULTS: There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device from rabbit skulls. CONCLUSION: Assessment of operative procedures led to the conclusion that piezoelectric ultrasound was shown to be a safe tool in the surgical approach to the maxillary sinus of rabbits, allowing sinus membrane integrity to be maintained during surgical procedures.OBJETIVO: A técnica de levantamento de seio maxilar apresenta como possível complicação a perfuração da membrana sinusal. O presente trabalho teve por objetivo comparar duas técnicas que utilizam a cirurgia ultrassônica para realização de enxerto autógeno para levantamento de seio maxilar. MÉTODOS: Dez coelhos foram utilizados no estudo, sendo que um deles não foi submetido a procedimento cirúrgico. Os nove coelhos operados tiveram os seios maxilares preenchidos com enxertos autógenos coletados de díploe externa de calota craniana, nas formas particulado do lado direito e raspado do lado esquerdo, ambos com aparelho ultrassônico. Os dados de densidade óssea nos seios maxilares esquerdo e direito, obtidos por meio de tomografia computadorizada nos

  14. Phishtest: Measuring the Impact of Email Headers on the Predictive Accuracy of Machine Learning Techniques

    Science.gov (United States)

    Tout, Hicham

    2013-01-01

    The majority of documented phishing attacks have been carried by email, yet few studies have measured the impact of email headers on the predictive accuracy of machine learning techniques in detecting email phishing attacks. Research has shown that the inclusion of a limited subset of email headers as features in training machine learning…

  15. Effect of solubility parameter of monomers on electron beam induced graft-polymerization onto polyethylene films

    International Nuclear Information System (INIS)

    Mori, Koji; Koshiishi, Kenji; Masuhara, Ken-ichi

    1991-01-01

    Electron beam induced graft-polymerization by the mutual irradiation technique of monomers with different solubility parameters δ onto low density polyethylene films (LDPE) and high density polyethylene films (HDPE) were investigated at high dose rates (25 Mrad per second). Graft-polymerization mechanisms were discussed on the basis of grafting rates, surface tensions, atomic ratios of surface by XPS, and SEM images of the grafted films. Grafting rates decreased with increasing δ of monomers, and grafting rates onto LDPE were larger than those onto HDPE. Graft chain contents on surface, which were evaluated in terms of surface tensions and atomic ratios of the surface, increased with increasing δ of monomers, and graft chain contents on surface of HDPE were higher than those of LDPE. It is assumed that mutual solubility of PE and monomers, i.e., infiltration of monomers into PE during graft-polymerization influence grafting rates and graft sites in films. In case of high mutual solubility, grafting rates were large and graft sites spread from the surface into bulk. On the other hand, in case of low mutual solubility, grafting rates were small and graft sites localized on the surface of films. (author)

  16. Radiation-induced grafting of TMPM onto polypropylene

    International Nuclear Information System (INIS)

    Wang Huiliang; Li Hong; Chen Wenxiu

    1995-01-01

    The gamma radiation-induced graft copolymerization of 2,2,6,6-tetramethyl-4-piperidinyl-methacrylate (TMPM), a very effective hindered amine light stabilizer (HALS), onto polypropylene was investigated by simultaneous- irradiation technique. The various synthesis conditions on the graft content was studied. It was found that benzene, CCl 4 and petroleum ether are more effective than other solvents, the percent grafting reached 7.1% for benzene. The percent grafting is higher when graft copolymerization is carried out in argon atmosphere than those in air. For all the grafting copolymerization carried out in benzene and CCl 4 , percent grafting increase linearly from 1 to 5 Mrad and beyond 5 Mrad, a tendency to level off appeared. At a constant dose, the percent grafting was found to be higher at high dose rate until 228 rad/s. Percent grafting also increased continuously with increasing monomer concentration up to 2.85 mol/L, but significant increase in grafting was observed only up to 1.14 mol/L

  17. A review of DTCA techniques: Appraising their success and potential impact on medication users.

    Science.gov (United States)

    Babar, Zaheer-Ud-Din; Siraj, Ashna Medina; Curley, Louise

    2018-03-01

    Direct-to-consumer advertising (DTCA) has been present in some countries for nearly two decades. Its success and ramifications have been examined but not yet cataloged recently in a comprehensive manner. To review existing literature studies on the topic of DTCA techniques to provide an analysis of the current methods considered by drug marketers to enhance the effect of pharmaceutical product promotion and its success, as well as examine ramifications on the drug use process. A search of 7 electronic databases including MEDLINE and SCOPUS was conducted in December 2015, and updated until February 2016. A scientific review of literature (2008-2015) was performed to identify and collate information from relevant, peer reviewed original study articles investigating various DTCA techniques commonly employed in pharmaceutical promotion. A thematic analysis was undertaken to categorize categories of drug promotion, or techniques, and the saliency and impact of these. Nineteen original study articles were included in this review. All articles were based in the U.S. and New Zealand, where DTCA is legal. After reviewing all the articles, 4 themes with 11 subcategories were generated. These themes included disease mongering and medicalization, drug references, advertisement strategies and eDTCA. The themes describe different categories of techniques used to augment DTC advertisements to increase their impact and overall success in promoting a pharmaceutical product. Many DTCA techniques utilized by pharmaceutical marketers are beneficial to the success of DTC promotion of a drug. These techniques include the use of drug efficacy information, comparative claims, non-branded help seeking advertisements, formatted risks information, celebrity or expert endorsers and website trust factors. Through their use, public perception of the drug is made more favorable, increased attention is drawn to the advertisement, and the pharmaceutical product gains greater credibility and

  18. Experimental Technique for Producing and Recording Precise Particle Impacts on Transparent Window Materials

    Science.gov (United States)

    Gray, Perry; Guven, Ibrahim

    2016-01-01

    A new facility for making small particle impacts is being developed at NASA. Current sand/particle impact facilities are an erosion test and do not precisely measure and document the size and velocity of each of the impacting particles. In addition, evidence of individual impacts is often obscured by subsequent impacts. This facility will allow the number, size, and velocity of each particle to be measured and adjusted. It will also be possible to determine which particle produced damage at a given location on the target. The particle size and velocity will be measured by high speed imaging techniques. Information as to the extent of damage and debris from impacts will also be recorded. It will be possible to track these secondary particles, measuring size and velocity. It is anticipated that this additional degree of detail will provide input for erosion models and also help determine the impact physics of the erosion process. Particle impacts will be recorded at 90 degrees to the particle flight path and also from the top looking through the target window material.

  19. An unusual case of fistula formation and thrombosis between arteriovenous graft and a native vein

    Directory of Open Access Journals (Sweden)

    Young Sub Kim

    2016-03-01

    Full Text Available Arteriovenous graft for hemodialysis vascular access is a widely used technique with many advantages. However, it has crucial complications with graft thrombosis and infection. We recently experienced an unusual case of arteriovenous graft complication involving graft thrombosis related to fistula formation between the graft and the natural vein with infection. We diagnosed this condition using Doppler ultrasound and computed tomography angiography. Successful surgical treatment including partial graft excision and creation of a secondary arteriovenous fistula using an inadvertently dilated cephalic vein was performed. The dialysis unit staff should keep this condition in mind and try to prevent this complication.

  20. Analysis of polymer grafted inside the porous hydrogel using confocal laser scanning microscopy

    Directory of Open Access Journals (Sweden)

    2007-04-01

    Full Text Available Graft polymerization of glycidyl methacrylate onto the pore surface of polyacrylamide macroporous gel was implemented in DMSO-aqueous solution using diperiodatocuprate(III complexes as an initiator. The grafting densities up to 410% were achieved. The graft polymerization was confirmed by gravimetrical methods and FTIR. The graft polymerization of polymer inside the pores of the macroporous gel resulted in increased flow resistance through the gel matrix. The distribution of grafted polymer on the gel pore surface material was studied by scanning electron microscopy (SEM and confocal laser scanning microscopy (CLSM. CLSM is an alternative method for studying morphology of gel surface with grafted polymer having the advantages over the SEM allowing to investigate the distribution of grafted polymer inside the hydrogel in a native hydrated state. The microscopic techniques demonstrated uneven distribution of the grafted polymer inside the gel pores as a result of initiating the graft polymerization by insoluble initiator deposited on the pore surface.

  1. Systematic comparative and sensitivity analyses of additive and outranking techniques for supporting impact significance assessments

    International Nuclear Information System (INIS)

    Cloquell-Ballester, Vicente-Agustin; Monterde-Diaz, Rafael; Cloquell-Ballester, Victor-Andres; Santamarina-Siurana, Maria-Cristina

    2007-01-01

    Assessing the significance of environmental impacts is one of the most important and all together difficult processes of Environmental Impact Assessment. This is largely due to the multicriteria nature of the problem. To date, decision techniques used in the process suffer from two drawbacks, namely the problem of compensation and the problem of identification of the 'exact boundary' between sub-ranges. This article discusses these issues and proposes a methodology for determining the significance of environmental impacts based on comparative and sensitivity analyses using the Electre TRI technique. An application of the methodology for the environmental assessment of a Power Plant project within the Valencian Region (Spain) is presented, and its performance evaluated. It is concluded that contrary to other techniques, Electre TRI automatically identifies those cases where allocation of significance categories is most difficult and, when combined with sensitivity analysis, offers greatest robustness in the face of variation in weights of the significance attributes. Likewise, this research demonstrates the efficacy of systematic comparison between Electre TRI and sum-based techniques, in the solution of assignment problems. The proposed methodology can therefore be regarded as a successful aid to the decision-maker, who will ultimately take the final decision

  2. assessment of environmental impacts in comfortable furniture production process using life cycle assessment (LCA technique

    Directory of Open Access Journals (Sweden)

    hejhar abbasi

    2016-12-01

    Full Text Available Furniture industry releases annually a large amount of volatile organic compound to the environment due to the use of adhesives, textiles, paints and coating materials. There are some different methods to measure the load of pollutions and the environmental impacts. Life cycle assessment (LCA is one of the best techniques. LCA is a technique in which all environmental impacts related to a product assessed all over its life cycle, from cradle to grave, and ultimately can be used to improve the production process and to prevent unsuitable environmental impacts. In summary, it can be concluded that the use of this technique is the basis for sustainable development and improving social, economic, and environmental indices. This study focused on the collecting of a comprehensive life cycle inventory data for comfortable furniture in two different production processes (B1 and B2 located in Tehran province, and analyzed the environmental impacts during the production process as gate to gate investigation. The results revealed that emissions in production process B1 were higher than that of production process B2. The reason for this is that basic operations such as sawing and frame assembling along with final operation have been done in the same unit for case B1. Textile production and usage, and polyurethane foam were identified as the main hotspots, respectively. Moreover, the results showed that comfortable furniture production process has the highest effects on ecosystem quality, human health, and resources (fossil fuels and mines, respectively.

  3. Adherence in patients in the first year after kidney transplantation and its impact on graft loss and mortality: a cross-sectional and prospective study.

    Science.gov (United States)

    Prihodova, Lucia; Nagyova, Iveta; Rosenberger, Jaroslav; Majernikova, Maria; Roland, Robert; Groothoff, Johan W; van Dijk, Jitse P

    2014-12-01

    To explore the predictive value of adherence to their immunosuppressive medication in kidney transplant recipients in the first year after kidney transplantation as a determinant of graft loss and mortality up to 12 years (prospective analysis) and its association with sociodemographic and medical factors and social support (cross-sectional analysis). Poor adherence to their immunosuppressive medication in kidney transplant recipients remains the leading preventable cause of poor patient outcomes. Prospective and cross-sectional study. At baseline, 325 patients 3-12 months posttransplantation were invited to participate. Adherence was assessed using collateral reports - a combination of patients' self-evaluation and an estimate by their nephrologist. The patients provided sociodemographic and medical data and completed the End-Stage Renal Disease Symptom Checklist and Multidimensional scale of perceived social support. At follow-up (average 7·1 years), data on patients and graft survival were obtained. All data were collected from 2002-2013. Multinomial regression analysis and Cox regression were performed. A total of 297 patients (48·1 (12·8) years, 61·6% men) agreed to participate (response rate 91·4%); 67·4% were considered as fully adherent. Poor adherence was associated with higher risk of graft loss and mortality over 12 years. Female sex, higher education, higher perceived side effects of corticosteroids, better perceived cardiac and renal function and higher perceived family social support in the first year posttransplantation were associated with full adherence to immunosuppressive treatment. Patients with poor adherence to the immunosuppressive medication in the first year after kidney transplantation showed increased likelihood of graft loss and death over 12 years compared with the adherent patients. © 2014 John Wiley & Sons Ltd.

  4. Health impacts of mercury cycling in contaminated environments in China studied by nuclear techniques

    International Nuclear Information System (INIS)

    Wang Dingyong; Qing Changle; Shi Xiaojun; Zheng Yonghua; Li Bo; Yang Xuechun

    2001-01-01

    Mercury is a highly toxic non-essential element. The mercury cycling in natural environments is a complex process. In recent years, the stable mercury isotope tracer and related analytical techniques have been developed. They offer unique possibility to understand the biogeochemistry of mercury in various environmental conditions. So a new co-ordinated research project (CRP) on health impacts of mercury cycling in contaminated environments studied by nuclear techniques has been supported by the IAEA. This paper introduces the research project whose IAEA research contract number is CPR-10874. It includes the scientific background, scope of the project, methods, some results related to this CRP and the plans for future work. (author)

  5. Impact of Detoxification Techniques on Pulmonary Gas Exchange Function in Patients with Generalized Peritonitis

    Directory of Open Access Journals (Sweden)

    R. A. Mlinnik

    2012-01-01

    Full Text Available Objective: to analyze the impact of different detoxification techniques on pulmonary gas exchange function in patients with generalized peritonitis complicated by multiple organ failure. Subjects and methods. One hundred and thirty patients with generalized peritonitis were examined. According to the used detoxification techniques, the patients were divided into 5 groups. All the patients underwent a comprehensive examination, the key element of which was the evaluation of gas exchange parameters. Results. Membrane plasmapheresis and plasmapheresis with sodium hypochlorite infusion to the plasma filter in patients with peritonitis are shown to improve pulmonary blood oxygenation.

  6. Health impacts of mercury cycling in contaminated environments in China studied by nuclear techniques

    International Nuclear Information System (INIS)

    Wang Dingyong; Shi Xiaojun; Wei Shiqiang; Zheng Yonghua; Qing Changle

    2002-01-01

    Mercury is a highly toxic non-essential element. The mercury cycling in natural environments is a complex process. In recent years, the stable mercury isotope tracer and related analytical techniques have been developed. They offer unique possibility to understand the biogeochemistry of mercury in various environmental conditions. So a new coordinated research project (CRP), on health impacts of mercury cycling in contaminated environments studied by nuclear techniques, has been supported by the IAEA. This paper introduces the research project which is IAEA research contract number CPR-10874. It includes the scientific background, scope of the project, methods, some results related to this CRP and the plans for future work. (author)

  7. Mic it! microphones, microphone techniques, and their impact on the final mix

    CERN Document Server

    Corbett, Ian

    2014-01-01

    Capture great sound in the first place, and spend less time ""fixing it in the mix"" with Ian Corbett's Mic It! Microphones, Microphone Techniques, and Their Impact on the Final Mix. With his expert guidance, you'll quickly understand essential audio concepts as they relate to microphones and mic techniques, and learn how to apply them to your recording situation. Whether you only ever buy one microphone, are equipping a studio on a budget, or have a vast selection of great mics to use, you'll learn to better use whatever tools you have. Mic It! gives you the background to design and discover

  8. Impact of Three Different Immobilization Techniques on Batch Fermentation Performance and Substrate Inhibition

    OpenAIRE

    Gurazi, Vilma; Xhagolli, Luljeta; Troja, Rozana; Vaso, Terkida; Karaj, Dafina

    2017-01-01

    This paper is focused on comparing three different immobilized yeast fermentations performance and impact of substrate inhibition on the process. The yeast used for this study was a brewing strain of Saccharomyces cerevisiae. The immobilization techniques used were: entrapment and capsulation method in alginate and immobilization in gelatin structure. Objective of this study was to make a comparison in terms of specific growth rate of microorganisms and kinetic constants.  Fermentations were ...

  9. Acrylamide graft over silicone rubber tubes by simultaneous irradiation in 60 Co source

    International Nuclear Information System (INIS)

    Julio, C.A.; Higa, O.Z.

    1992-01-01

    The synthesis of a hydrogel having silicone rubber tubes as support was carried out through the radiation grafting technique. The best conditions for the grafting development were determined in relation to the monomer and inhibitor concentration, dose rate and irradiation dose. The addition of cupric ions in the process inhibited the acrylamide homo polymerization and enhanced the grafting yield. The water content in the grafted tubes characterized the hydrophilic property of the material. (author)

  10. Synthesis, Characterization and Evaluation of the Transformations in Hibiscus sabdariffa-graft-poly(butyl acrylate

    Directory of Open Access Journals (Sweden)

    B. S. Kaith

    2008-01-01

    Full Text Available Different reaction parameters for the graft copolymerization of butyl acrylate onto Hibiscus sabdariffa fiber were optimized. Graft copolymers thus obtained were subjected to characterization using XRD, TGA, DTA, SEM and FTIR techniques and were evaluated for physio-chemical changes in the behavior. The percentage crystallinity and crystallinity index were found to decrease with increase in grafting while there was reduction in moisture absorption and increase in chemical, thermal resistance of the graft copolymers.

  11. Use of a Piezosurgery Technique to Remove a Deeply Impacted Supernumerary Tooth in the Anterior Maxilla

    Science.gov (United States)

    Sukegawa, Shintaro; Kanno, Takahiro; Kawakami, Kiyokazu; Shibata, Akane; Takahashi, Yuka; Furuki, Yoshihiko

    2015-01-01

    Deeply impacted supernumerary teeth in the anterior maxillary cannot be generally removed by the conventional labial or palatal surgical approach because of the risk of damaging the surrounding soft tissues and the possibility of injuring the roots of adjacent permanent teeth. In piezosurgery, bony tissues are selectively cut, thereby avoiding the soft tissue damage caused by rotary cutting instruments. We report the case of a 15-year-old Japanese boy from whom a deeply impacted supernumerary tooth in the anterior maxillary was safely removed through the floor of the nasal cavity. The surgical extraction was performed without damaging the nasal mucosa or adjacent structures such as the roots of the adjacent permanent teeth. Considering that piezosurgery limits the extent of surgical invasion, this technique can be practiced as a minimally invasive and safe surgical procedure for treating suitably selected cases with a deeply impacted supernumerary tooth. PMID:26779355

  12. Use of a Piezosurgery Technique to Remove a Deeply Impacted Supernumerary Tooth in the Anterior Maxilla

    Directory of Open Access Journals (Sweden)

    Shintaro Sukegawa

    2015-01-01

    Full Text Available Deeply impacted supernumerary teeth in the anterior maxillary cannot be generally removed by the conventional labial or palatal surgical approach because of the risk of damaging the surrounding soft tissues and the possibility of injuring the roots of adjacent permanent teeth. In piezosurgery, bony tissues are selectively cut, thereby avoiding the soft tissue damage caused by rotary cutting instruments. We report the case of a 15-year-old Japanese boy from whom a deeply impacted supernumerary tooth in the anterior maxillary was safely removed through the floor of the nasal cavity. The surgical extraction was performed without damaging the nasal mucosa or adjacent structures such as the roots of the adjacent permanent teeth. Considering that piezosurgery limits the extent of surgical invasion, this technique can be practiced as a minimally invasive and safe surgical procedure for treating suitably selected cases with a deeply impacted supernumerary tooth.

  13. The impact of information technology on productivity using structural equations technique in Iran Behnoush Company

    Directory of Open Access Journals (Sweden)

    Mina Beig

    2012-08-01

    Full Text Available Information technology plays an important role on increasing productivity in many organizations. The primary objective of the present survey is to study the impact of information technology on productivity and find a positive and significant relationship between these two factors. Structural equations technique and LISREL software are used for analysis of the questionnaires distributed among managers and some employees of Iran Behnoush Company. Organizations try to improve their performance by investment in information technology. However, many of the previous studies indicate insignificance of the impact of information technology on productivity of the organizations. The present survey studies the impact of information technology on organizations' productivity through the collected data from the above company. Results confirm existence of a positive relationship between information technology and productivity.

  14. Different effect of scion types on callusing in bench grafting

    African Journals Online (AJOL)

    use

    2011-10-31

    Oct 31, 2011 ... burst scion, burst cutting-swollen scion, and burst cutting-unburst scion. 21 days after ..... Vol 2: Vegetable, Viticulture, Ornamental. Plants. 4-7 Sept. ... Resonance Imaging Technique (MRI) to investigate graft connection.

  15. Dysphagia after Colon Interposition Graft for Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    C. Spitali

    2012-01-01

    Full Text Available Colon interposition is an established technique for esophageal reconstruction. We describe the case of primary adenocarcinoma arising in a colonic interposition graft that was performed after total esophagectomy for recurrence adenocarcinoma derived from the Barrett esophagus.

  16. Environmental impacts of Tehran poultry slaughterhouse of nemone using TOPSIS technique

    Directory of Open Access Journals (Sweden)

    Seyed Ali Jozi

    2013-11-01

    Full Text Available Background: The current research was carried out to assess the environmental impacts caused by Tehran Poultry Slaughterhouse of Nemone and to offer an Environmental Management Plan. Methods: In this research, Technique for Order Preference by Similarity to Ideal Solution (TOPSIS, as one of the most reliable techniques from Multi Attribute Decision Making (MADM, was applied to assess environmental impacts caused by Tehran Poultry Slaughterhouse of Nemone. Thus, by determining the related options and criteria of decision making Matrix, the weight of indices and options were calculated and graded. After identification and prediction of the slaughterhouse impacts on the environment, he required criteria and potential options were identified through analyzing the impacts. Delphi questionnaire was applied to finalize the introduced criteria. Then TOPSIS method was utilized in 6 steps. Results: Among the most significant impacts in the slaughterhouse, the first priority was allocated to the wastewater with the weight of 1following the noise, air and odor pollution with the weights of 0.664, 0.508 and 0.327 respectively. Noise assessment results indicated that the measured noise was beyond the permissible level. The results of air pollutions experiments were lower than that of the standard. Conclusion: The results indicated that the effluent quality was not suitable to be discharged into the surface water or wells and it was not suitable for irrigational and agricultural purposes too. To minimize the environmental harmful impacts of slaughterhouse, the environmental management plan was proposed of which the most important case was the optimization of the wastewater treatment system.

  17. Synthesis of electron beam grafted poly-propylene (PP) membranes for selective adsorption of uranium from sea water

    International Nuclear Information System (INIS)

    Bhardwaj, Y.K.; Virendra Kumar; Sabharwal, S.

    2001-01-01

    Graft co polymerisation of Acrylonitrile (AN) onto porous polypropylene (PP) by post irradiation technique using electron beam (EB) irradiation were studied with regards to various parameters of importance like grafting time, dose rate and horizontal stacking. Grafting of AN causes hardening as well as yellow colouration of the white flexible PP substrate sheets. Grafting reaches saturation limits of ∼130 % after grafting for 2-3 hours and no significant increase in grafting extents is seen after this period. Higher grafting levels are achieved at low dose rates. Keeping the ratio of volume of grafting solution and weight of PP substrate constant, simultaneous grafting of 10-12 PP sheets can be carried out by horizontal stacking without much variation in the grafting limits between the stacked sheets. (author)

  18. Grafted Cellulose Based Adsorbents for Selective Separation Purposes

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E; Wojnarovits, L [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary)

    2012-09-15

    The effect of high energy ionizing radiation on cotton-cellulose was studied. It was found that degradation of cellulose started at low doses, below 5 kGy, resulting in decrease in the degree of polymerization. However, the mechanical properties of cotton-cellulose samples only slightly changed with the dose up to 40 kGy. Acrylate type monomers were successfully grafted to cellulose by mutual and by pre-irradiation grafting technique. With both techniques the grafting yield increased with increasing dose and monomer concentration. In the case of pre-irradiation grafting the increase in grafting time also resulted in an increase in grafting percentage. Cotton-cellulose was functionalized using pre-irradiation grafting (PIG) and simultaneous grafting (SG) of glycidyl methacrylate (GMA). The adsorption properties of this material were further enhanced by {beta}-cyclodextrin (CD) immobilization. This molecule is known for its unique ability to form inclusion complexes among others with aromatic compounds like phenols, pesticide, dyes, etc. (author)

  19. Piezosurgery for the Lingual Split Technique in Lingual Positioned Impacted Mandibular Third Molar Removal

    Science.gov (United States)

    Ge, Jing; Yang, Chi; Zheng, Jiawei; Qian, Wentao

    2016-01-01

    Abstract The aim of this study was to evaluate the effect and safety of lingual split technique using piezosurgery for the extraction of lingual positioned impacted mandibular 3rd molars with the goal of proposing a more minimally invasive choice for this common surgery. Eighty-nine consecutive patients with 110 lingual positioned impacted mandibular 3rd molars requiring extraction were performed the lingual split technique using piezosurgery. One sagittal osteotomy line and 2 transverse osteotomy line were designed for lingual and occlusal bone removal. The success rate, operative time, postoperative outcome, and major complications (including nerve injury, mandible fracture, severe hematoma or edema, and severe pyogenic infection) were documented and analyzed. All impacted mandibular 3rd molars were successfully removed (110/110). The average time of operation was 14.6 minutes (ranged from 7 to 28 minutes). One hundred and seven extraction sites (97.3%) were primary healing. Pain, mouth opening, swelling, and PoSSe scores on postoperative 7-day were 0.34 ± 0.63, 3.88 ± 0.66(cm), 2.4 ± 0.2(cm), and 23.7 ± 5.9, respectively. There were 6 cases (5.5%) had lingual nerve disturbance and 3 cases (2.7%) developed inferior alveolar nerve impairment, and achieved full recovery within 2 months by neurotrophic drug treatment. Our study suggested piezosurgery for lingual split technique provided an effective way for the extraction of lingual positioned and deeply impacted mandibular 3rd molar. PMID:27015214

  20. Frenuloplasty with a splitthicknes skin graft

    International Nuclear Information System (INIS)

    Mohammadi, G.; Nnaderpour, M.

    2006-01-01

    The purpose of this study was to investigate the severity of presenting symptomatology in patients with ankyloglossia and to assess the surgical results of patients undergoing frenuloplasty with split thickness skin graft. During a 4 year period from September 1998 through September 2002, 19 patients of ankyloglosia underwent frenuloplasty with a split thickness skin graft. All skin grafts were taken from arm. There were 11 males and 8 females. The average length of the lingual frenulum was 3.5 mm. Twelve children were over 4 years old and were primarily operated with this technique. In the 7 patients, Z plasty had been performed previously but failed and cicatrisation caused ankyloglosia. There were two minor postoperative complications, one hematoma, and other graft dehiscence with cicatrisation. The mobility of the tongue after one year was excellent. There were no complications in donor site. Frenuloplasty with split thickness skin graft is the best and easy procedure with good results for children over 4 years and those who fail primary closure. (author)

  1. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  2. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  3. Primary nerve grafting: A study of revascularization.

    Science.gov (United States)

    Chalfoun, Charbel; Scholz, Thomas; Cole, Matthew D; Steward, Earl; Vanderkam, Victoria; Evans, Gregory R D

    2003-01-01

    It was the purpose of this study to evaluate the revascularization of primary nerve repair and grafts using orthogonal polarization spectral (OPS) (Cytometrix, Inc.) imaging, a novel method for real-time evaluation of microcirculatory blood flow. Twenty male Sprague Dawley rats (250 g) were anesthetized with vaporized halothane and surgically prepared for common peroneal nerve resection. Group I animals (n = 10) underwent primary neurorraphy following transection, utilizing a microsurgical technique with 10-0 nylon suture. Group II (n = 10) animals had a 7-mm segment of nerve excised, reversed, and subsequently replaced as a nerve graft under similar techniques. All animals were evaluated using the OPS imaging system on three portions (proximal, transection site/graft, and distal) of the nerve following repair or grafting. Reevaluation of 5 animals randomly selected from each group using the OPS imaging system was again performed on days 14 and 28 following microsurgical repair/grafting. Values were determined by percent change in vascularity of the common peroneal nerve at 0 hr following surgery. Real-time evaluation of blood flow was utilized as an additional objective criterion. Percent vascularity in group I and II animals increased from baseline in all segments at day 14. By day 28, vascularity in nerves of group I rats decreased in all segments to values below baseline, with the exception of the transection site, which remained at a higher value than obtained directly after surgical repair. In group II animals, vascularity remained above baseline in all segments except the distal segment, which returned to vascularity levels similar to those at 0 hr. Further, occlusion of the vessels demonstrated in the graft and distal segments following initial transection appeared to be corrected. This study suggests that revascularization may occur via bidirectional inosculation with favored proximal vascular growth advancement. The use of real-time imaging offers a

  4. Microwave based synthesis and spectral characterization of thermo-sensitive poly(N,N-diethylacrylamide) grafted pectin copolymer.

    Science.gov (United States)

    Işıklan, Nuran; Tokmak, Şeyma

    2018-07-01

    The functionalization of polysaccharides with synthetic polymers has attracted great attention owing to its application in many industrial fields. The aim of this work was to study the impact of pectin functionalization with N,N-diethylacrylamide (DEAAm). Pectin was modified via microwave-induced graft copolymerization of DEAAm using ceric ammonium nitrate (CAN) and N,N,N',N'-tetramethylethylenediamine (TEMED). FTIR, 13 C NMR, DSC/TGA, XRD, and SEM techniques were used to verify the structure of graft copolymers. Various reaction conditions such as microwave irradiation time, temperature, microwave power, monomer, initiator, and TEMED concentrations were investigated to get a maximum grafting yield of 192%. Lower critical solution temperatures (LCST) of graft copolymers were determined by UV spectroscopy. Graft copolymers were found to be thermo-sensitive, with LCST of 31°C and high thermal resistance. Biocompatibility test of copolymers showed that copolymers were not cytotoxic to L929 fibroblasts cells and can be used as a biomaterial. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Infeccion urinaria temprana en trasplante renal: Factores de riesgo y efecto en la sobrevida del injerto Early urinary tract infection in kidney transplantation: Risk factors and impact on graft sur-vival

    Directory of Open Access Journals (Sweden)

    Pablo A. Cepeda

    2005-10-01

    risk factors to EUTI, the assessment of the causal agent and graft survival impact. A retrospective analysis of kidney transplantation, period 1997-2000 in Hospital Privado-Centro Médico de Córdoba was carried out. There were two groups of patients with (EUTI group and without EUTI (control group. Cox model was used to analyze risk factors and Kaplan-Meier method for graft survival. A total of 226 consecutive patients received kidney transplantation. In 55 patients (24.3% EUTI was detected. Risk factors for EUTI were: invasive urological maneuvers (RR=4.34, CI 95% 1.42-13.21, diabetes mellitus (RR=3.79, CI 95% 1.42-10.14, cytomegalovirus infection (RR=2.9, CI 95% 1.02-8.24 and previous transplants (RR=2.83, CI 95% 1.08-7.45. Delayed graft function was associated with lower incidence of EUTI (RR=0.38, CI 95% 0.15-0.94. The causal agents were: Klebsiella pneumoniae (36%, Pseudomonas aeruginosa (24% and Escherichia coli (9%. Graft survival at 2 years was similar in EUTI (87.2% and control group (81.2%, p= 0.32. This series shows that invasive urological maneuvers were the main risk factors for EUTI. Graft survival was similar. High prevalence of non coli bacteria need further evaluation.

  6. Modified technique to increase nostril cross-sectional area after using rib and septal cartilage graft over alar nasal cartilages Técnica modificada para aumentar a área seccional externa da narina após o uso de enxerto cartilaginoso de costela e septo sob as cartilagens alares nasais

    Directory of Open Access Journals (Sweden)

    Marcelo Wulkan

    2012-10-01

    Full Text Available PURPOSE: Describe a modified technique to increase nostril cross-sectional area using rib and septal cartilage graft over alar nasal cartilages. METHODS: A modified surgical technique was used to obtain, carve and insert cartilage grafts over alar nasal cartilages. This study used standardized pictures and measured 90 cadaveric nostril cross-sectional area using Autocad®; 30 were taken before any procedure and 60 were taken after grafts over lateral crura (30 using costal cartilage and 30 using septal cartilage. Statistical analysis were assessed using a model for repeated measures and ANOVA (Analysis of Variance for the variable "area". RESULTS: There's statistical evidence that rib cartilage graft is more effective than septal cartilage graft. The mean area after the insertion of septal cartilage graft is smaller than the mean area under rib graft treatment (no confidence interval for mean difference contains the zero value and all P-values are below the significance level of 5%. CONCLUSIONS: The technique presented is applicable to increase nostril cross section area in cadavers. This modified technique revealed to enhance more nostril cross section area with costal cartilage graft over lateral crura rather than by septal graft.OBJETIVO: Descrever uma técnica modificada para se aumentar a área seccional externa da narina com cartilagem septal e costal acima das cartilagens alares nasais. MÉTODOS: Utilizou-se uma técnica cirúrgica modificada para obter, esculpir e inserir enxertos de cartilagem sobre as cartilagens alares. Realizou-se fotos padronizadas e mensuração de 90 áreas seccionais externas de narina em cadáveres com Autocad®; 30 antes sem procedimento; 60 após a inclusão de enxertos sob a cruz lateral (30 usando cartilagem costal e 30 usando cartilagem septal. A análise estatística foi feita com um modelo de medidas repetidas e ANOVA para a variável "área" RESULTADOS: Existe evidência estatística de que o enxerto de

  7. Intensifying radiation induced grafting of 4-vinylpyridine/glycidyl methacrylate mixtures onto poly(ethylene-co-tetrafluoroethylene) films using ultrasound

    International Nuclear Information System (INIS)

    Nasef, Mohamed Mahmoud; Sithambaranathan, Paveswari; Ahmad, Arshad; Abouzari-lotf, Ebrahim

    2017-01-01

    A new ultrasound-aided method was used to enhance grafting of 4-vinylpyridine (4-VP) and glycidyl methacrylate (GMA) monomers mixtures onto electron beam (EB) irradiated poly(ethylene-co-tetrafluoroethylene) (ETFE) film for the first time. The effects of reaction parameters such as absorbed dose, monomer concentration, reaction time on both of degree of grafting (DG) and grafting efficiency (GE) were investigated under sonication and conventional grafting at similar temperatures. Fourier transform infrared (FTIR) and atomic force microscopy (AFM) were used to monitor the impact of the applied ultrasound on composition and surfaces of the grafted films whereas 1 H-NMR was used to investigate composition of the grafting residues. The ultrasound-aided grafting of 4-VP/GMA was found to enhance both of DG% and GE remarkably. Moreover, it produced grafted ETFE films having smoother surfaces without homopolymer contamination compared to grafted films obtained from conventional grafting. The results of this study suggest that the use of ultrasound is a promising way for intensifying grafting process and improving its economy. - Highlights: • Grafting of 4-VP/GMA onto ETFE films was carried out with the aid of ultrasound. • Degree of grafting was found to be strongly dependent on reaction parameters. • Sonication remarkably enhanced the reaction kinetics and grafting efficiency. • Grafted films with smoother surfaces without homopolymer contamination were obtained. • Ultrasound aided grafting is superior to conventional one and promotes intensification.

  8. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain: impact on respiratory muscle function, activity, mood and exercise capacity.

    Science.gov (United States)

    Aida, Nobuko; Shibuya, Masako; Yoshino, Katsuki; Komoda, Masaji; Inoue, Tomoko

    2002-12-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) groups. Rib cage dominant breathing was observed postoperatively in both groups. With preoperative tan deltaVrc/deltaVab, increases at 1-week postoperatively and decreases at discharge for S-group tended to exceed those of C-group (p > .05). Decreased maximum inspiratory and expiratory pressure status for functional residual capacity and percent forced expiratory volume in one second at discharge again only tended to be smaller for S-group (p > .05). S-group displayed significantly reduced pain around both scapulas at discharge (p = .049), and increased mean overall ADL and profile of mood states (POMS)/Vigor scores (p = .031 and p = .018, respectively). POMS/Tension-Anxiety scores at discharge for S-group were significantly smaller than those preoperatively (p = .025), and S-group displayed significantly increased distance walked over 6-minutes at discharge than C-group (p = .029). New-RH improves patient participation in exercise therapy and increases exercise capacity by reducing PCP, relieving anxiety and tension, and improving ADL.

  9. Genome-wide identification and comparative analysis of grafting-responsive mRNA in watermelon grafted onto bottle gourd and squash rootstocks by high-throughput sequencing.

    Science.gov (United States)

    Liu, Na; Yang, Jinghua; Fu, Xinxing; Zhang, Li; Tang, Kai; Guy, Kateta Malangisha; Hu, Zhongyuan; Guo, Shaogui; Xu, Yong; Zhang, Mingfang

    2016-04-01

    Grafting is an important agricultural technique widely used to improve plant growth, yield, and adaptation to either biotic or abiotic stresses. However, the molecular mechanisms underlying grafting-induced physiological processes remain unclear. Watermelon (Citrullus lanatus L.) is an important horticultural crop worldwide. Grafting technique is commonly used in watermelon production for improving its tolerance to stresses, especially to the soil-borne fusarium wilt disease. In the present study, we used high-throughput sequencing to perform a genome-wide transcript analysis of scions from watermelon grafted onto bottle gourd and squash rootstocks. Our transcriptome and digital gene expression (DGE) profiling data provided insights into the molecular aspects of gene regulation in grafted watermelon. Compared with self-grafted watermelon, there were 787 and 3485 genes differentially expressed in watermelon grafted onto bottle gourd and squash rootstocks, respectively. These genes were associated with primary and secondary metabolism, hormone signaling, transcription factors, transporters, and response to stimuli. Grafting led to changes in expression of these genes, suggesting that they may play important roles in mediating the physiological processes of grafted seedlings. The potential roles of the grafting-responsive mRNAs in diverse biological and metabolic processes were discussed. Obviously, the data obtained in this study provide an excellent resource for unraveling the mechanisms of candidate genes function in diverse biological processes and in environmental adaptation in a graft system.

  10. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  11. [Features of skin graft in pediatric plastic surgery].

    Science.gov (United States)

    Depoortère, C; François, C; Belkhou, A; Duquennoy-Martinot, V; Guerreschi, P

    2016-10-01

    Skin graft is a skin tissue fragment transferred from a donor site to a receiving site with a spontaneous revascularization. Basic process of plastic surgery, skin graft known in children, specific, warnings and refinements. It finds its indication in many pediatric cases: integumental diseases (neavus, hamartoma), acute burns and scars, traumatic loss of substance or surgically induced, congenital malformations of the hands and feet, etc. Specific skin graft techniques in children are developed: donor sites, sampling technique and procedure, early postoperative care. Especially in children, the scalp is a perfect site for split skin graft and technique is actively developed. Refinements and special cases are discussed: use of dermal matrices, allografts, xenografts, negative pressure therapy, prior skin expansion of the donor site. Results of skin graft in children are exposed: taking of graft, growth and shrinkage, pigmentation. Skin graft sometimes allows to stay the complex movement and get the best final benefit, permanent or at least temporary, in a growing being. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Experts: despite time constraints, motivational interviewing techniques can have lasting impact on drinkers, drug abusers.

    Science.gov (United States)

    2013-04-01

    Researchers have found that the Brief Negotiation Interview (BNI), a tool developed at Yale School of Medicine in New Haven, CT, can curb harmful drinking in patients when the tool is used with these patients in the emergency setting. Further, by using the same motivational interviewing techniques employed in the tool, experts say providers can help patients curb other harmful behaviors as well. The BNI consists of a series of questions that take about seven minutes to discuss with patients. The tool prompts patients to come up with their own reasons for changing harmful behaviors. To implement the BNI, emergency providers need training and constant reinforcement. Ideally, experts say the motivational interviewing techniques employed in the BNI need to become routine to have a lasting impact on patient care.

  13. Translating Public Policy: Enhancing the Applicability of Social Impact Techniques for Grassroots Community Groups

    Directory of Open Access Journals (Sweden)

    Melissa Edwards

    2013-08-01

    Full Text Available This paper reports on an exploratory action research study designed to understand how grassroots community organisations engage in the measurement and reporting of social impact and how they demonstrate their social impact to local government funders. Our findings suggest that the relationships between small non-profit organisations, the communities they serve or represent and their funders are increasingly driven from the top down formalised practices. Volunteer-run grassroots organisations can be marginalized in this process. Members may lack awareness of funders’ strategic approaches or the formalized auditing and control requirements of funders mean grassroots organisations lose capacity to define their programs and projects. We conclude that, to help counter this trend, tools and techniques which open up possibilities for dialogue between those holding power and those seeking support are essential.

  14. The impact of e-ticketing technique on customer satisfaction: an empirical analysis

    Directory of Open Access Journals (Sweden)

    Mazen Kamal Qteishat

    2015-09-01

    Full Text Available Recently, internet technology is considered to be the most used information and communication technology by organizations: it can ease the process of transactions and reinforce the relation between companies and customers. This investigation empirically examines the impact of e-ticketing technique on customer satisfaction; a convenience sample of Jordanian airline passengers that had booked flights in the last 12 months through companies offering e-ticketing services was acquired. The findings indicate that customer satisfaction with e-ticketing services was influenced by all of the independent variables measured (Data security, Customer and Technical Support, and User-Friendliness were noted to have significant impact on customer satisfaction with e-ticketing services.

  15. On the Impact of using Mixed Integer Programming Techniques on Real-world Offshore Wind Parks

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    2017-01-01

    Wind power is a leading technology in the transition to sustainable energy. Being a new and still more competitive field, it is of major interest to investigate new techniques to solve the design challenges involved. In this paper, we consider optimization of the inter-array cable routing...... optimization problem considers two objectives: minimizing immediate costs (CAPEX) and minimizing costs due to power losses. This makes it possible to perform various what-if analyses to evaluate the impact of different preferences to CAPEX versus reduction of power losses. Thanks to the close collaboration...... with a leading energy company, we have been able to report results on a set of real-world instances, based on six existing wind parks, studying the economical impact of considering power losses in the cable routing design phase....

  16. Impact of fruit fly control programmes using the sterile insect technique

    International Nuclear Information System (INIS)

    Enkerlin, W.R.

    2005-01-01

    Measuring the impact of area-wide integrated pest management (AW-IPM) programmes, that use the sterile insect technique (SIT) to control fruit fly pests of economic significance, is complex. These programmes affect practically the whole horticultural food chain. In this chapter, the impact of the programmes is assessed by focusing only on the benefits generated to producers and traders of horticultural products, the direct beneficiaries. This is done first by describing the types of benefits accrued from these programmes, second by explaining the factors that shape programme benefits, and finally by presenting several examples to illustrate how the SIT technology, when properly applied for eradication, containment, suppression, or prevention purposes, can generate substantial direct and indirect benefits to the horticulture industry. (author)

  17. Radiation chemical grafting of vinyl acetate and styrene on nitrocellulose

    International Nuclear Information System (INIS)

    Chapiro, A.; Foex, M.; Jendrychowska-Bonamour, A.M.

    1977-01-01

    Vinyl acetate and styrene were grafted onto nitrocellulose using the direct radiation grafting technique with 500 and 3000 Ci 60 Co γ sources. For vinyl acetate, the reaction proceeds homogeneously. The kinetics are dominated by degradative chain transfer to the nitrocellulose. The polymerization of vinyl acetate was examined in the presence of isoamyl nitrate, a model for nitrocellulose; the transfer constant was determined and the results are treated semi-quantitatively. For styrene, grafting occurs in a swollen film irradiated in the presence of excess monomer. The diffusion of styrene into nitrocellulose is extremely slow; methanol was added to the reaction mixture to favour diffusion which was found to obey Fick's law. The diffusion constant and activation energy of diffusion are evaluated. The grafting kinetics are controlled by monomer diffusion, accounting for the increase of dose-rate exponent with temperature. A spontaneous grafting process occurs in the absence of irradiation. It is initiated by macroradicals arising from thermal decomposition of nitrocellulose. (author)

  18. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  19. Evaluating the effect of river restoration techniques on reducing the impacts of outfall on water quality

    Science.gov (United States)

    Mant, Jenny; Janes, Victoria; Terrell, Robert; Allen, Deonie; Arthur, Scott; Yeakley, Alan; Morse, Jennifer; Holman, Ian

    2015-04-01

    Outfalls represent points of discharge to a river and often contain pollutants from urban runoff, such as heavy metals. Additionally, erosion around the outfall site results in increased sediment generation and the release of associated pollutants. Water quality impacts from heavy metals pose risks to the river ecosystem (e.g. toxicity to aquatic habitats). Restoration techniques including establishment of swales, and the re-vegetation and reinforcement of channel banks aim to decrease outfall flow velocities resulting in deposition of pollutants and removal through plant uptake. Within this study the benefits of river restoration techniques for the removal of contaminants associated with outfalls have been quantified within Johnson Creek, Portland, USA as part of the EPSRC funded Blue-Green Cities project. The project aims to develop new strategies for protecting hydrological and ecological values of urban landscapes. A range of outfalls have been selected which span restored and un-restored channel reaches, a variety of upstream land-uses, and both direct and set-back outfalls. River Habitat Surveys were conducted at each of the sites to assess the level of channel modification within the reach. Sediment samples were taken at the outfall location, upstream, and downstream of outfalls for analysis of metals including Nickel, Lead, Zinc, Copper, Iron and Magnesium. These were used to assess the impact of the level of modification at individual sites, and to compare the influence of direct and set-back outfalls. Concentrations of all metals in the sediments found at outfalls generally increased with the level of modification at the site. Sediment in restored sites had lower metal concentrations both at the outfall and downstream compared to unrestored sites, indicating the benefit of these techniques to facilitate the effective removal of pollutants by trapping of sediment and uptake of contaminants by vegetation. However, the impact of restoration measures varied

  20. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    Science.gov (United States)

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  1. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  2. RANGELAND DEGRADATION: EXTENT, IMPACTS, AND ALTERNATIVE RESTORATION TECHNIQUES IN THE RANGELANDS OF ETHIOPIA

    Directory of Open Access Journals (Sweden)

    Mohammed Mussa Abdulahi

    2016-12-01

    Full Text Available Rangeland degradation remains a serious impediment to improve pastoral livelihoods in the lowlands of Ethiopia. This review paper presents an overview of the extent of rangeland degradation, explores its drivers, discusses the potential impacts of rangeland degradation and also suggests alternative rangeland restoration techniques. It is intended to serve as an exploratory tool for ensuing more detailed quantitative analyses to support policy and investment programs to address rangeland degradation in Ethiopia. The extent of rangeland degradation increases with time, and the productivity of rangelands are losing if not given due attention. The major drivers leading to rangeland degradation includes climate change, overgrazing, bush encroachment, population pressure, drought, and government policy, encroachment of rain fed agriculture and decline of traditional resource management institution. Degradation of rangeland has resulted in substantial declines in rangeland condition, water potential, soil status, and animal performance, livestock holding at the household level and community become destitute. Another consequence of rangeland degradation is linked to food insecurity, poverty to the extent of food aid, expansion of aridity and the need for alternative livelihood and income diversification. Moreover, it has increasingly become a threat to the pastoral production systems, and has contributed towards increases in poverty and tribal conflicts over grazing land and water resources. In spite of these impacts, the adoption of alternative restoration techniques in the country is highly insufficient. To address rangeland degradation problems, there is a strong need to substantially increase the investments and strengthen the policy support for sustainable land management.

  3. Preparation of membranes by radiation grafting of acrylic acid onto Teflon-FEP film

    International Nuclear Information System (INIS)

    Gupta, B.D.

    1991-01-01

    The grafting of acrylic acid on radiation-peroxidised Teflon-FEP film provides an effective technique to prepare ion-exchange membranes. It was found that the grafted membranes have very high degree of swelling in aqueous KOH. The electric resistance of the film decreases considerably by grafting. An electric resistance of 0.2Ω cm 2 was obtained for a graft level beyond 58%. The hydrophilicity of the film was evaluated in terms of contact angle which shows a decreasing trend with the increasing degree of grafting. (author). 8 refs

  4. POTENTIAL USE OF GRAFT COPOLYMERS OF MERCERIZED FLAX AS FILLER IN POLYSTYRENE COMPOSITE MATERIALS

    Directory of Open Access Journals (Sweden)

    Susheel Kalia

    2008-11-01

    Full Text Available Graft copolymerization of binary vinyl monomers onto mercerized flax fiber was carried out for the enhancement of mechanical properties of polystyrene composites. Binary vinyl monomer mixture of AA+AN has been found to show maximum grafting (33.55% onto mercerized flax. Graft copolymers thus synthesized were characterized with FT-IR spectroscopy, SEM, and TGA techniques. Mercerized flax (MF showed maximum thermal stability in comparison to graft copolymers. It has been found that polystyrene composites reinforced with graft copolymers showed improvement in mechanical properties such as wear resistance, compressive strength, and tensile strength.

  5. Primary renal graft thrombosis

    NARCIS (Netherlands)

    Bakir, N; Sluiter, WJ; Ploeg, RJ; van Son, WJ; Tegzess, Adam

    Background. Renal allograft thrombosis is a serious complication of kidney transplantation that ultimately leads to graft loss. Its association with acute and hyperacute rejection is well documented; however, in a large proportion of patients the precise cause remains obscure. The exact incidence

  6. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  7. Impact produced by seoi-otoshi technique. Relation to years in practice and judo rank

    Directory of Open Access Journals (Sweden)

    Carlos Montero Carretero

    2014-02-01

    Full Text Available Judokas commonly train the seoi-otoshi technique (aka, drop-knee seoi-nage. A controversy exists about the convenience of its use by the younger judokas due to the risk of high loads produced by the impacts on their growing structures. The aim of the present paper was to measure the impacts against the tatami when executing the knee seoi-otoshi technique and its relationship with the years of practice and the degree or level (color of the belt. Thirty-three judokas from different years and degree volunteered to participate. Two force plates covered by standard tatami, registered the ground reaction forces while five consecutive repetitions were executed. We measured the mean and maximum peaks of force relative to their own body weight (BW. The results show peaks of more than 10 BW, which can be considered a potential risk of injury in the younger judokas, especially when repeated in time. In addition, a tendency to decrease the impact as the years of practice increase is observed (potential function; R2= 0.41, p<0.000 in the force peak, and the force in the expert group has been significantly lower than in the other groups (p<0.001. On the other hand, the degree (belt color shows a quadratic relationship (R2= 0.45, p<0.000 in the force peak. The lack of agreement between the years of practice and the degree shows that the promotion criteria does not appear to be a valid one from a preventive viewpoint, especially in the lower degrees which would correspond to younger practitioners whose locomotor structures are still not fully developed.

  8. Chronology of DIC technique based on the fundamental mathematical modeling and dehydration impact.

    Science.gov (United States)

    Alias, Norma; Saipol, Hafizah Farhah Saipan; Ghani, Asnida Che Abd

    2014-12-01

    A chronology of mathematical models for heat and mass transfer equation is proposed for the prediction of moisture and temperature behavior during drying using DIC (Détente Instantanée Contrôlée) or instant controlled pressure drop technique. DIC technique has the potential as most commonly used dehydration method for high impact food value including the nutrition maintenance and the best possible quality for food storage. The model is governed by the regression model, followed by 2D Fick's and Fourier's parabolic equation and 2D elliptic-parabolic equation in a rectangular slice. The models neglect the effect of shrinkage and radiation effects. The simulations of heat and mass transfer equations with parabolic and elliptic-parabolic types through some numerical methods based on finite difference method (FDM) have been illustrated. Intel®Core™2Duo processors with Linux operating system and C programming language have been considered as a computational platform for the simulation. Qualitative and quantitative differences between DIC technique and the conventional drying methods have been shown as a comparative.

  9. Impact of radiation technique upon the outcome of treatment for medulloblastoma

    International Nuclear Information System (INIS)

    Halperin, Edward C.

    1996-01-01

    Craniospinal irradiation (CSI) is an essential component of the therapy of medulloblastoma. Because medulloblastoma disseminates via the cerebrospinal fluid (CSF), CSI technique involves the irradiation of all CSF-bearing areas which are at risk for tumor seeding. Underdosing with radiation because of inadequacies in CSI technique will produce dose 'cold spots' which have the potential of serving as a nidus for tumor recurrence. A simple mathematic model of subclinical disease in medulloblastoma based on the available data concerning the radiosensitivity of medulloblastoma cell lines as well as the known clinical dose-response relationships support the hypothesis that for most cases of medulloblastoma, the radiotherapist is working in a range of doses arrayed on the steep portion of the tumor control probability curve. Underdosing of CSF-bearing areas because of technical problems at the junction of the cranial and spinal fields of irradiation, placement of shielding blocks in the cribiform plate-sub frontal region, and/or anatomic errors in the design of the caudal end of the CSI fields may lead to significant risks of tumor relapse. One may debate the necessity of a posterior fossa boost encompassing the entire anatomic posterior fossa rather than the primary tumor volume with a margin. This review critically evaluates the potential impact of CSI technique upon the outcome of treatment for medulloblastoma, and suggests future areas of inquiry

  10. Grafting of activated carbon cloths for selective adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Gineys, M.; Benoit, R.; Cohaut, N.; Béguin, F.; Delpeux-Ouldriane, S., E-mail: delpeux@cnrs-orleans.fr

    2016-05-01

    Graphical abstract: - Highlights: • A controlled grafting of carboxylic functions on activated carbon fibers. • The carbon material nanotextural properties preservation after grafting. • An identification of the grafting mechanism through ToF SIMS analysis. • A chemical mapping of the grafted surface using ToF SIMS technique and imaging. - Abstract: Chemical functionalization of an activated carbon cloth with 3-aminophthalic acid and 4-aminobenzoic acid groups by the in situ formation of the corresponding diazonium salt in aqueous acidic solution is reported. The nature and amount of selected functions on an activated carbon surface, in particular the grafted density, were determined by potentiometric titration, elemental analysis and X-ray photoelectron spectroscopy (XPS). The nanotextural properties of the modified carbon were explored by gas adsorption. Functionalized activated carbon cloth was obtained at a discrete grafting level while preserving interesting textural properties and a large porous volume. Finally, the grafting homogeneity of the carbon surface and the nature of the chemical bonding were investigated using Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) technique.

  11. Proximal tubular dysfunction as an indicator of chronic graft dysfunction

    Directory of Open Access Journals (Sweden)

    N.O.S. Câmara

    2009-03-01

    Full Text Available New strategies are being devised to limit the impact of renal sclerosis on graft function. Individualization of immunosuppression, specifically the interruption of calcineurin-inhibitors has been tried in order to promote better graft survival once chronic graft dysfunction has been established. However, the long-term impact of these approaches is still not totally clear. Nevertheless, patients at higher risk for tubular atrophy and interstitial fibrosis (TA/IF development should be carefully monitored for tubular function as well as glomerular performance. Since tubular-interstitial impairment is an early event in TA/IF pathogenesis and associated with graft function, it seems reasonable that strategies directed at assessing tubular structural integrity and function would yield important functional and prognostic data. The measurement of small proteins in urine such as α-1-microglobulin, N-acetyl-beta-D-glucosaminidase, alpha/pi S-glutathione transferases, β-2 microglobulin, and retinol binding protein is associated with proximal tubular cell dysfunction. Therefore, its straightforward assessment could provide a powerful tool in patient monitoring and ongoing clinical assessment of graft function, ultimately helping to facilitate longer patient and graft survival associated with good graft function.

  12. Nickel adsorption by sodium polyacrylate-grafted activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Ewecharoen, A. [Division of Biotechnology, School of Bioresources and Technology, King Mongkut' s University of Technology Thonburi, 83 Moo 8 Thakham, Bangkhuntien, Bangkok 10150 (Thailand); Thiravetyan, P., E-mail: paitip@hotmail.com [Division of Biotechnology, School of Bioresources and Technology, King Mongkut' s University of Technology Thonburi, 83 Moo 8 Thakham, Bangkhuntien, Bangkok 10150 (Thailand); Wendel, E.; Bertagnolli, H. [Institut fuer Physikalische Chemie, Universitaet Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart (Germany)

    2009-11-15

    A novel sodium polyacrylate grafted activated carbon was produced by using gamma radiation to increase the number of functional groups on the surface. After irradiation the capacity for nickel adsorption was studied and found to have increased from 44.1 to 55.7 mg g{sup -1}. X-ray absorption spectroscopy showed that the adsorbed nickel on activated carbon and irradiation-grafted activated carbon was coordinated with 6 oxygen atoms at 2.04-2.06 A. It is proposed that this grafting technique could be applied to other adsorbents to increase the efficiency of metal adsorption.

  13. Amino acids grafting of Ar+ ions modified PE

    International Nuclear Information System (INIS)

    Svorcik, V.; Hnatowicz, V.; Stopka, P.; Bacakova, L.; Heitz, J.; Oechsner, R.; Ryssel, H.

    2001-01-01

    Polyethylene (PE) was irradiated with 63 keV Ar + ions to the fluences from 1x10 12 to 3x10 15 cm -2 and then grafted at room temperature from water solution with amino acids (alanine, leucine). Using various spectroscopic techniques (UV-VIS, FTIR, RBS and EPR) it was shown that the amino acids penetrate into PE where they are eventually captured either on double bonds or on free radicals created by the ion irradiation. Grafting with amino acids in the whole specimen layer modified by irradiation is observed. The ion-beam-modified and amino-acid grafted PE is supposed to exhibit increased biocompatibility. (author)

  14. Transcriptomic Analysis Provides Insights into Grafting Union Development in Pecan (Carya illinoinensis).

    Science.gov (United States)

    Mo, Zhenghai; Feng, Gang; Su, Wenchuan; Liu, Zhuangzhuang; Peng, Fangren

    2018-02-05

    Pecan ( Carya illinoinensis ), as a popular nut tree, has been widely planted in China in recent years. Grafting is an important technique for its cultivation. For a successful grafting, graft union development generally involves the formation of callus and vascular bundles at the graft union. To explore the molecular mechanism of graft union development, we applied high throughput RNA sequencing to investigate the transcriptomic profiles of graft union at four timepoints (0 days, 8 days, 15 days, and 30 days) during the pecan grafting process. After de novo assembly, 83,693 unigenes were obtained, and 40,069 of them were annotated. A total of 12,180 differentially expressed genes were identified between by grafting. Genes involved in hormone signaling, cell proliferation, xylem differentiation, cell elongation, secondary cell wall deposition, programmed cell death, and reactive oxygen species (ROS) scavenging showed significant differential expression during the graft union developmental process. In addition, we found that the content of auxin, cytokinin, and gibberellin were accumulated at the graft unions during the grafting process. These results will aid in our understanding of successful grafting in the future.

  15. Transcriptomic Analysis Provides Insights into Grafting Union Development in Pecan (Carya illinoinensis

    Directory of Open Access Journals (Sweden)

    Zhenghai Mo

    2018-02-01

    Full Text Available Pecan (Carya illinoinensis, as a popular nut tree, has been widely planted in China in recent years. Grafting is an important technique for its cultivation. For a successful grafting, graft union development generally involves the formation of callus and vascular bundles at the graft union. To explore the molecular mechanism of graft union development, we applied high throughput RNA sequencing to investigate the transcriptomic profiles of graft union at four timepoints (0 days, 8 days, 15 days, and 30 days during the pecan grafting process. After de novo assembly, 83,693 unigenes were obtained, and 40,069 of them were annotated. A total of 12,180 differentially expressed genes were identified between by grafting. Genes involved in hormone signaling, cell proliferation, xylem differentiation, cell elongation, secondary cell wall deposition, programmed cell death, and reactive oxygen species (ROS scavenging showed significant differential expression during the graft union developmental process. In addition, we found that the content of auxin, cytokinin, and gibberellin were accumulated at the graft unions during the grafting process. These results will aid in our understanding of successful grafting in the future.

  16. Punch grafts to treat lower limb intractable sores

    Directory of Open Access Journals (Sweden)

    JÚLIO WILSON FERNANDES

    Full Text Available ABSTRACT Lower limb recurrent ulcers, usually caused by prolonged decubitus, trauma, diabetes or burns, may not heal with conventional clinical or surgical treatment. Frequently, laminated skin grafts do not integrate with the recipient layer, and the only alternatives are neighbor microsurgical flaps. These have higher morbidity and create secondary defects, to be corrected with skin grafts, when fasciocutaneous or miocutaneous segments are removed for the treatment of the primary defect. We describe the non-conventional use of punch grafts in the treatment of lower limb ulcers, when conventional skin laminated graft failed, without the use of flaps. Since this is a very successful technique, its use should be considered as a valuable alternative for the treatment of recurrent lower limb ulcers. It is a simple and easy-learned technique that may be used by different surgeons, even in remote places without correct specialized hospital facilities.

  17. The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer

    International Nuclear Information System (INIS)

    Wu, Q. Jackie; Thongphiew, Danthai; Wang Zhiheng; Chankong, Vira; Yin Fangfang

    2008-01-01

    Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less

  18. Martial arts fall techniques reduce hip impact forces in naive subjects after a brief period of training.

    NARCIS (Netherlands)

    Weerdesteijn, V.G.M.; Groen, B.E.; Swigchem, R. van; Duysens, J.E.J.

    2008-01-01

    Hip fractures are among the most serious consequences of falls in the elderly. Martial arts (MA) fall techniques may reduce hip fracture risk, as they are known to reduce hip impact forces by approximately 30% in experienced fallers. The purpose of this study was to investigate whether hip impact

  19. A technique for the assessment of the visual impact of nearshore confined dredged materials and other built islands

    Science.gov (United States)

    Roy Mann

    1979-01-01

    Drilling rigs, confined dredged material disposal sites power and sewage treatment facilities, and other built objects on or near shorelines have often created appreciable impacts on the aesthetic perceptions of residents and recreational users. Techniques for assessing such impacts that are reviewed in this paper include viewscape analysis for large-scale shore...

  20. Simulation Tools and Techniques for Analyzing the Impacts of Photovoltaic System Integration

    Science.gov (United States)

    Hariri, Ali

    utility simulation software. On the other hand, EMT simulation tools provide high accuracy and visibility over a wide bandwidth of frequencies at the expense of larger processing and memory requirements, limited network size, and long simulation time. Therefore, there is a gap in simulation tools and techniques that can efficiently and effectively identify potential PV impact. New planning simulation tools are needed in order to accommodate for the simulation requirements of new integrated technologies in the electric grid. The dissertation at hand starts by identifying some of the potential impacts that are caused by high PV penetration. A phasor-based quasi-static time series (QSTS) analysis tool is developed in order to study the slow dynamics that are caused by the variations in the PV generation that lead to voltage fluctuations. Moreover, some EMT simulations are performed in order to study the impacts of PV systems on the electric network harmonic levels. These studies provide insights into the type and duration of certain impacts, as well as the conditions that may lead to adverse phenomena. In addition these studies present an idea about the type of simulation tools that are sufficient for each type of study. After identifying some of the potential impacts, certain planning tools and techniques are proposed. The potential PV impacts may cause certain utilities to refrain from integrating PV systems into their networks. However, each electric network has a certain limit beyond which the impacts become substantial and may adversely interfere with the system operation and the equipment along the feeder; this limit is referred to as the hosting limit (or hosting capacity). Therefore, it is important for utilities to identify the PV hosting limit on a specific electric network in order to safely and confidently integrate the maximum possible PV systems. In the following dissertation, two approaches have been proposed for identifying the hosing limit: 1. Analytical

  1. Off-pump versus on-pump coronary artery bypass grafting for ischaemic heart disease

    DEFF Research Database (Denmark)

    Møller, Christian H; Penninga, Luit; Wetterslev, Jørn

    2012-01-01

    Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear.......Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear....

  2. Grafting improves cucumber water stress tolerance in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulaziz R. Al-Harbi

    2018-02-01

    Full Text Available Water scarcity is a major limiting factor for crop productivity in arid and semi-arid areas. Grafting elite commercial cultivars onto selected vigorous rootstocks is considered as a useful strategy to alleviate the impact of environmental stresses. This study aims to investigate the feasibility of using grafting to improve fruit yield and quality of cucumber under water stress conditions. Alosama F1 cucumber cultivar (Cucumis sativus L. was grafted onto Affyne (Cucumis sativus L. and Shintoza A90 (Cucurbitamaxima × C. moschata rootstocks. Non-grafted plants were used as control. All genotypes were grown under three surface drip irrigation regimes: 50%, 75% and 100% of the crop evapotranspiration (ETc, which represent high-water stress, moderate-water stress and non-water stress conditions, respectively. Yield and fruit quality traits were analyzed and assessed. In comparison to the non-grafted plants, the best grafting treatment under water stress was Alosama F1 grafted onto Shintoza A90 rootstock. It had an overall improved yield and fruit quality under water stress owing to an increase in the total fruit yield by 27%, from 4.815 kg plant−1 in non-grafted treatment to 6.149 kg plant−1 in grafted treatment under moderate -water stress, total soluble solid contents (13%, titratable acidity (39% and vitamin C (33%. The soil water contents were low in soil surface and increase gradually with soil depth, while salt distribution showed an adverse trend. The positive effects of grafting on plant growth, productivity, and water use efficiency support this strategy as an useful tool for improving water stress tolerance in greenhouse grown cucumber in Saudi Arabia.

  3. Grafting improves cucumber water stress tolerance in Saudi Arabia.

    Science.gov (United States)

    Al-Harbi, Abdulaziz R; Al-Omran, Abdulrasoul M; Alharbi, Khadiga

    2018-02-01

    Water scarcity is a major limiting factor for crop productivity in arid and semi-arid areas. Grafting elite commercial cultivars onto selected vigorous rootstocks is considered as a useful strategy to alleviate the impact of environmental stresses. This study aims to investigate the feasibility of using grafting to improve fruit yield and quality of cucumber under water stress conditions. Alosama F 1 cucumber cultivar ( Cucumis sativus L.) was grafted onto Affyne ( Cucumis sativus L.) and Shintoza A90 ( Cucurbitamaxima × C. moschata ) rootstocks. Non-grafted plants were used as control. All genotypes were grown under three surface drip irrigation regimes: 50%, 75% and 100% of the crop evapotranspiration (ETc), which represent high-water stress, moderate-water stress and non-water stress conditions, respectively. Yield and fruit quality traits were analyzed and assessed. In comparison to the non-grafted plants, the best grafting treatment under water stress was Alosama F 1 grafted onto Shintoza A90 rootstock. It had an overall improved yield and fruit quality under water stress owing to an increase in the total fruit yield by 27%, from 4.815 kg plant -1 in non-grafted treatment to 6.149 kg plant -1 in grafted treatment under moderate -water stress, total soluble solid contents (13%), titratable acidity (39%) and vitamin C (33%). The soil water contents were low in soil surface and increase gradually with soil depth, while salt distribution showed an adverse trend. The positive effects of grafting on plant growth, productivity, and water use efficiency support this strategy as an useful tool for improving water stress tolerance in greenhouse grown cucumber in Saudi Arabia.

  4. The Impact of the Immediate Feedback Assessment Technique on Course Evaluations

    Directory of Open Access Journals (Sweden)

    Trent W. Maurer

    2015-09-01

    Full Text Available This project reports the results of two studies that investigated the impact on course evaluations of using partial credit iterative responding (PCIR with the Immediate Feedback Assessment Technique (IF-AT forms on summative course assessments. This project also quantifies grade inflation from utilizing different PCIR schemes and documents the percentage of possible partial credit students learned. Study 1 compared evaluations in courses where exams were manipulated. Study 2 compared evaluations in courses where daily reading quizzes were manipulated. Results from Study 1 revealed that multiple course evaluation scores increased 10% in the PCIR condition. Students earned 75% of the partial credit available through PCIR, which resulted in a 10% increase in their exam scores. Results from Study 2 revealed no difference in course evaluations between conditions. Students earned roughly 40% of the partial credit available through PCIR, resulting in a 4 to 8% increase in their quiz scores, depending on the PCIR scheme.

  5. Fluorescence spectroscopy for assessment of liver transplantation grafts concerning graft viability and patient survival

    Science.gov (United States)

    Vollet Filho, José D.; da Silveira, Marina R.; Castro-e-Silva, Orlando; Bagnato, Vanderlei S.; Kurachi, Cristina

    2015-06-01

    Evaluating transplantation grafts at harvest is essential for its success. Laser-induced fluorescence spectroscopy (LIFS) can help monitoring changes in metabolic/structural conditions of tissue during transplantation. The aim of the present study is to correlate LIFSobtained spectra of human hepatic grafts during liver transplantation with post-operative patients' mortality rate and biochemical parameters, establishing a method to exclude nonviable grafts before implantation. Orthotopic liver transplantation, piggyback technique was performed in 15 patients. LIFS was performed under 408nm excitation. Collection was performed immediately after opening donor's abdominal cavity, after cold perfusion, end of back-table period, and 5 min and 1 h after warm perfusion at recipient. Fluorescence information was compared to lactate, creatinine, bilirubin and INR levels and to survival status. LIFS was sensitive to liver changes during transplantation stages. Study-in-progress; initial results indicate correlation between fluorescence and life/death status of patients.

  6. Impact of molecular weight and degree of conjugation on the thermodynamics of DNA complexation and stability of polyethylenimine-graft-poly(ethylene glycol) copolymers.

    Science.gov (United States)

    Smith, Ryan J; Beck, Rachel W; Prevette, Lisa E

    2015-01-01

    Poly(ethylene glycol) (PEG) is often conjugated to polyethylenimine (PEI) to provide colloidal stability to PEI-DNA polyplexes and shield charge leading to toxicity. Here, a library of nine cationic copolymers was synthesized by grafting three molecular weights (750, 2000, 5000Da) of PEG to linear PEI at three conjugation ratios. Using isothermal titration calorimetry, we have quantified the thermodynamics of the associations between the copolymers and DNA and determined the extent to which binding is hindered as a function of PEG molecular weight and conjugation ratio. Low conjugation ratios of 750Da PEG to PEI resulted in little decrease in DNA affinity, but a significant decrease-up to two orders of magnitude-was found for the other copolymers. We identified limitations in determination of affinity using indirect assays (electrophoretic mobility shift and ethidium bromide exclusion) commonly used in the field. Dynamic light scattering of the DNA complexes at physiological ionic strength showed that PEI modifications that did not reduce DNA affinity also did not confer significant colloidal stability, a finding that was supported by calorimetric data on the aggregation process. These results quantify the DNA interaction thermodynamics of PEGylated polycations for the first time and indicate that there is an optimum PEG chain length and degree of substitution in the design of agents that have desirable properties for effective in vivo gene delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Impact of geometric uncertainties on evaluation of treatment techniques for prostate cancer

    International Nuclear Information System (INIS)

    Craig, Tim; Wong, Eugene; Bauman, Glenn; Battista, Jerry; Van Dyk, Jake

    2005-01-01

    Purpose: To assess the impact of patient repositioning and internal organ motion on prostate treatment plans using three-dimensional conformal and intensity-modulated radiotherapy. Methods and materials: Four-field, six-field, and simplified intensity-modulated arc therapy plans were generated for 5 prostate cancer patients. The planning target volume was created by adding a 1-cm margin to the clinical target volume. A convolution model was used to estimate the effect of random geometric uncertainties during treatment. Dose statistics, tumor control probabilities, and normal tissue complication probabilities were compared with and without the presence of uncertainty. The impact of systematic uncertainties was also investigated. Results: Compared with the planned treatments, the delivered dose distribution with random geometric uncertainties displayed an increase in the apparent minimal dose to the prostate and seminal vesicles and a decrease in the rectal volume receiving a high dose. This increased the tumor control probabilities and decreased the normal tissue complication probabilities. Changes were seen in the percentage of prostate volume receiving 100% and 95% of the prescribed dose, and the minimal dose and tumor control probabilities for the target volume. In addition, the volume receiving at least 65 Gy, the minimal dose, and normal tissue complication probabilities changed considerably for the rectum. The simplified intensity-modulated arc therapy technique was the most sensitive to systematic errors, especially in the anterior-posterior and superior-inferior directions. Conclusion: Geometric uncertainties should be considered when evaluating treatment plans. Contrary to the widely held belief, increased conformation of the dose distribution is not always associated with increased sensitivity to random geometric uncertainties if a sufficient planning target volume margin is used. Systematic errors may have a variable effect, depending on the treatment

  8. A new method of modelling early plasma creatinine changes predicts 1-year graft function after kidney transplantation

    DEFF Research Database (Denmark)

    Krogstrup, Nicoline V; Bibby, Bo Martin; Aulbjerg, Camilla

    2016-01-01

    BACKGROUND: Delayed graft function after renal transplantation is associated with inferior long-term outcome. To evaluate the impact of slow onset graft function, we aimed to model and correlate early changes in plasma creatinine (p-cr) with long-term graft function. MATERIALS: In a single centre...

  9. Barriers to the universal adoption of bilateral internal mammary artery grafting.

    Science.gov (United States)

    Umakanthan, Jeremiah; Jeyakumar, Panch; Umakanthan, Branavan; Jeyakumar, Nikeshan; Senthilkumar, Nadarajah; Saraswathy, Mathioli R; Umakanthan, Padminidevi; Umakanthan, Janani; Sial, Tamoor; Abrina, Sofia; Buendia, Frances M; Pan, Irene; Kamath, Ramadas K; Pathmarajah, Canagaratnam; Sivalingam, Kanagaratnam; Nathan, Shan A; Sunder, Shun K; Mahendra, Tom; Umakanthan, Ramanan

    2015-04-01

    The left internal mammary artery (LIMA) graft is considered the "gold standard" of coronary artery bypass grafting (CABG). This conduit provides increased survival, symptomatic relief, increased freedom from myocardial infarction, and increased freedom from re-intervention when compared to saphenous venous grafting. It has a remarkable long term patency rate with clinical and angiographic outcomes that are unmatched by other conduits. Given the fact that patients often require more than one graft during a coronary revascularization procedure, the prospect of bilateral internal mammary artery (BIMA) grafting has been very appealing to some surgeons. BIMA grafting has been extensively studied via multiple retrospective and prospective cohort studies and findings have indicated that BIMA grafting can have an increased survival benefit when compared to LIMA grafting alone. As a result, this technique has accrued increasing popularity over the course of the last decade. Yet, questions still remain on whether BIMA grafting is the optimal treatment modality for patients in terms of long-term prognosis. There is limited data at the present time from randomized controlled trials and only 4-12% of CABGs performed today utilize BIMA grafting. Concerns regarding perioperative complications, which patient subsets are at higher risks for complications from the technique, and the technical challenges involved in utilizing and teaching the technique have limited its widespread use. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  10. Use of nuclear techniques and hydrochemical analysis to evaluate the impact of tailings dams

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Flaviane M.; Fleming, Peter M.; Fonseca, Flávio H. da R.; Pimenta, Rafael C.; Moreira, Rubens M., E-mail: flaviane@cdtn.br, E-mail: pmf@cdtn.br, E-mail: flavio.fonseca@cdtn.br, E-mail: colombopimenta@gmail.com, E-mail: rubens@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The mining industry is a most important productive segment to country's economy. However, it is important to recognize and monitor the environmental impacts caused by mining, such as dams. They are structures built to store the waste produced by the beneficiation of ores, through chemical and mechanical processes classified as concentrate, crude ore or tailings. Tailings dams are associated with a potential risk of disruption and can therefore cause various images to the environment and population. Seepage flows and transport mechanisms are parameters to indicate the structural integrity. Nuclear technology can be used as a tool to trace these parameters. The objective of this work is to use isotopic techniques and hydrochemical characterization to detect leaks in dams belonging to a mining company. The isotopic techniques are used to measure the concentration of environmental isotopes in dam waters and their mediations, among which deuterium ({sup 2}H) and oxygen-18 ({sup 18}O) are measured. These isotopes will be used as environmental tracers to investigate the presence of infiltrations through the displacement of the water in its flow in the aquifer, since they are constituent of the molecule of water. In parallel, the basic physical chemical parameters and water quality parameters will be measured in-situ to aid in the interpretation of the results of the isotopic analyzes. Thus, it is intended to provide data that can help the environmental agencies to make decisions regarding the decommissioning of the mine. (author)

  11. Impact of corpus domain for sentiment classification: An evaluation study using supervised machine learning techniques

    Science.gov (United States)

    Karsi, Redouane; Zaim, Mounia; El Alami, Jamila

    2017-07-01

    Thanks to the development of the internet, a large community now has the possibility to communicate and express its opinions and preferences through multiple media such as blogs, forums, social networks and e-commerce sites. Today, it becomes clearer that opinions published on the web are a very valuable source for decision-making, so a rapidly growing field of research called “sentiment analysis” is born to address the problem of automatically determining the polarity (Positive, negative, neutral,…) of textual opinions. People expressing themselves in a particular domain often use specific domain language expressions, thus, building a classifier, which performs well in different domains is a challenging problem. The purpose of this paper is to evaluate the impact of domain for sentiment classification when using machine learning techniques. In our study three popular machine learning techniques: Support Vector Machines (SVM), Naive Bayes and K nearest neighbors(KNN) were applied on datasets collected from different domains. Experimental results show that Support Vector Machines outperforms other classifiers in all domains, since it achieved at least 74.75% accuracy with a standard deviation of 4,08.

  12. Integration of datasets from different analytical techniques to assess the impact of nutrition on human metabolome

    Directory of Open Access Journals (Sweden)

    Pamela eVernocchi

    2012-12-01

    Full Text Available Bacteria colonizing the human intestinal tract exhibit a high phylogenetic diversity that reflects their immense metabolic potentials. The catalytic activity of gut microbes has an important impact on gastrointestinal (GI functions and host health. The microbial conversion of carbohydrates and other food components leads to the formation of a large number of compounds that affect the host metabolome and have beneficial or adverse effects on human health. Meabolomics is a metabolic-biology system approach focused on the metabolic responses understanding of living systems to physio-pathological stimuli by using multivariate statistical data on human body fluids obtained by different instrumental techniques. A metabolomic approach based on an analytical platform could be able to separate, detect, characterize and quantify a wide range of metabolites and its metabolic pathways. This approach has been recently applied to study the metabolic changes triggered in the gut microbiota by specific diet components and diet variations, specific diseases, probiotic and synbiotic food intake.This review describes the metabolomic data obtained by analyzing human fluids by using different techniques and particularly Gas Chromatography Mass Spectrometry Solid-phase Micro Extraction (GC-MS/SPME, Proton Nuclear Magnetic Resonance (1H-NMR Spectroscopy and Fourier Transform Infrared (FTIR Spectroscopy. This instrumental approach have a good potential in the identification and detection of specific food intake and diseases biomarkers.

  13. Impact of self-administered relaxation and guided imagery techniques during final trimester and birth.

    Science.gov (United States)

    Gedde-Dahl, Merete; Fors, Egil A

    2012-02-01

    The objective of this study was to test if and how self-administered practice of relaxation techniques, positive affirmation and guided imagery, in the final part of pregnancy had an impact on giving birth. Further to see if the use of a simple method, a CD with a booklet, with no previous training or specific support of the participants (neither required nor delivered), affected the birth experience. Outcome measures were monitored both during and after delivery: During delivery, pain and anxiety were measured at different stages of birth. Post-delivery Wellbeing (Edmonton Scale 0-10, where 10 is the worst possible feeling of Wellbeing), pain, anxiety, Apgar score, duration of birth, complications and anesthesia/analgesic were recorded. Those in the CD-intervention group also reported how many times they had practiced the techniques. The study employed a randomized controlled trial. Results show that the CD-intervention group had a significantly better score on total Wellbeing, as measured by the ESAS (0-10) Edmonton Scale. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Impact of accelerator-based analytical techniques on the knowledge and conservation of cultural heritage

    International Nuclear Information System (INIS)

    Dran, Jean Claude

    2001-01-01

    A large set of modern analytical techniques is currently applied to get a better insight on art and archaeological objects as well as to contribute to their conservation and restoration. Because of the precious and sometimes unique character of the works, non-destructive techniques and even those requiring no (or only minute) sampling, are preferred. From this standpoint, ion beam analysis (IBA) constitutes one of the best choices, since it combines quite good analytical performance and non-destructiveness. For over 10 years, an IBA facility has been installed in the Research Laboratory of the Museums of France. Until now it is the only facility of this kind entirely devoted to the study of cultural heritage. A special set-up, namely an external beam line, has been developed which permits the in-air analysis of large or fragile works of art without sampling. This facility is used for both short investigations at the request of museum curators and extensive research works in art history and archaeology. Numerous examples will be given to highlight the impact of this tool on cultural heritage. (author)

  15. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  16. Integrity of high-velocity water slug generated by an impacting technique

    Science.gov (United States)

    Dehkhoda, Sevda; Bourne, Neil

    2013-06-01

    A pulsed water jet is a series of discrete water slugs travelling at high velocity. Immediately after striking a target, these slugs apply high-intensity, short-duration transient stress known as the water hammer pressure, followed by low-intensity, long-duration stationary stress at the stagnation pressure. The magnitude and duration of the water hammer and stagnation pressures are controlled by the size and quality of the water slugs. The use of water jets for rock cutting in mining operations is a centuries-old technology; however, practical methods for producing high-energy water slugs repeatedly have proven difficult. This can be partly due to the fact that the geometrical properties of a jet and so its effectiveness in creating damage is controlled and influenced by the method that is employed to generate the water slugs. This paper investigates the integrity of a single water slug produced using an impacting technique where a hammer strikes a piston, resting on top of a water-filled chamber. The coherence of the generated water pulse was of concern in this study. If repeated shock reflections within the chamber were transmitted or were carried into the internal geometry of nozzle, the emerging jet could pulsate. The impact impulse of the formed water jet was measured in a Kel-F target material using an embedded PVDF (Polyvinylidene fluoride) shock gauge. The recorded stress waveform was then used to study the quality and endurance of the water pulse stream as it travelled through air.

  17. Production of a high-velocity water slug using an impacting technique

    Science.gov (United States)

    Dehkhoda, S.; Bourne, N. K.

    2014-02-01

    A pulsed water jet consists of a series of discrete water slugs travelling at high velocity. Immediately after striking a target, these slugs apply high-intensity, short-duration transient stress pulses reaching an amplitude known as the water hammer pressure, followed by low-intensity, long-duration stationary stress at a lower stagnation pressure. The magnitude and duration of the water hammer and stagnation pressures are controlled by the size and quality of the water slugs. The use of water jets for rock cutting in mining operations is a centuries-old technology; however, practical methods for producing high-energy water slugs repeatedly have proven difficult. This can be partly due to the fact that the geometrical properties of a jet and so its effectiveness in creating damage is controlled and influenced by the method that is employed to generate the water slugs. This paper investigates the quality of a single water slug produced using an impacting technique where a hammer strikes a piston, resting on top of a water-filled chamber. The coherence and integrity of the jet core was of concern in this study. The impact impulse of the formed water jet was measured in a Kel-F target material using an embedded PVDF (Polyvinylidene fluoride) shock gauge. The recorded stress waveform was then used to determine the unity and endurance of the water slug stream once travelled through air.

  18. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting

    DEFF Research Database (Denmark)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor

    2017-01-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal...... and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft...... enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat...

  19. Journey of bone graft materials in periodontal therapy: A chronological review

    Directory of Open Access Journals (Sweden)

    Jitendra Kumar

    2016-01-01

    Full Text Available Bone, the basic building block of the healthy periodontium, is affected in most of the periodontal diseases and can be managed either by mechanically recontouring it or by grafting techniques, which encourages regeneration where it has been lost. Bone replacement grafts are widely used to promote bone formation and periodontal regeneration. Bone grafting, placing bone or bone substitutes into defects created by the disease process, acts like a scaffold upon which the body generates its own, new bone. A wide range of bone grafting materials, including bone grafts and bone graft substitutes, have been applied and evaluated clinically, including autografts, allografts, xenografts, and alloplasts. This review provides an overview of the clinical application, biologic function, and advantages and disadvantages of various types of bone graft materials used in periodontal therapy till date with emphasis on recent advances in this field.

  20. Revascularization of femoral head ischemic necrosis with vascularized bone graft: A CT scan experimental study

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Knapp, K.; Gomez Castresana, F.; Benito, M.

    1990-01-01

    An ischemic necrosis of the femoral head was induced in 15 mongrel adult dogs using the technique described by Gartsman et al. Five weeks later, a free vascularized rib graft was transferred into the previously induced ischemic femoral head. High resolution computed tomographic scanning was used to evaluate revascularization 4, 8 and 12 weeks after grafting. The femoral head exhibited new vessel formation throughout the study. Arterial terminal branches arising from the rib graft medullary and periosteal circulations extended beyond the rib graft, entered the head, and reached the subchondral plate. Even where the rib graft did not replenish the central core of the head, there was vascular supply from the grafted bone's vascular tree. These results suggest that a free vascularized bone graft is able to revascularize an experimentally induced ischemic femoral head necrosis. (orig.)

  1. Isotopic scintigraphy in kidney grafting

    International Nuclear Information System (INIS)

    Renfro, Richard.

    1976-01-01

    Isotopic explorations of kidney transplants were performed on sixty-six patients. Three scintigraphic techniques were used: labelled ferrous ascorbate scintigraphy, sequential 99m technetium DTPA scintigraphy and the 131 I hippuran nephrogram. The aim of this study is to analyse the results obtained under different pathological circumstances affecting the transplant, to discuss the advantages of the techniques and to propose a working procedure. The most reliable and accurate technique is the 131 I hippuran nephrogram combined with sequential 99mTc DTPA, by which renal vascularisation may be judged labelled ferrous ascorbate on the other hand is too insensitive. Although the information supplied is mostly contained in the scintigraphic images, the nephrographic curves and the blood radioactivity decay time and rad V/rad R ratio measurements are very helpful in the early diagnosis and differential diagnosis of complications affecting the transplant. The proper use of isotopic scintigraphy in kidney grafting should provide optimum conditions for better survival of the transplant at minimum risk to the patient [fr

  2. Application of fisheries management techniques to assessing impacts: task I report. [Assessment of chemical, radiological, and thermal impacts of nuclear power plants on fish populations

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Baker, K.S.; Fickeisen, D.H.; Metzger, R.M.; Skalski, J.R.

    1979-03-01

    Task I efforts examined the available fisheries management techniques and assessed their potential application in a confirmatory monitoring program. The objective of such monitoring programs is to confirm that the prediction of an insignificant impact (usually made in the FES) was correct. Fisheries resource managers have developed several tools for assessing the fish population response to stress (exploitation) and they were thought potentially useful for detecting nuclear power plant impacts. Techniques in three categories were examined; catch removal, population dynamics, and nondestructive censuses, and the report contains their description, examples of application, advantages, and disadvantages. The techniques applied at nuclear power plant sites were examined in detail to provide information on implementation and variability of specific approaches. The most suitable techniques to incorporate into a monitoring program confirming no impact appear to be those based on Catch Per Unity Effort (CPUE) and hydroacoustic data. In some specific cases, age and growth studies and indirect census techniques may be beneficial. Recommendations for task II efforts to incorporate these techniques into monitoring program designs are presented. These include development of guidelines for; (1) designing and implementing a data collection program; (2) interpreting these data and assessing the occurrence of impact, and (3) establishment of the monitoring program's ability to detect changes in the affected populations.

  3. Perfect and least invasive sealing technique on the lesser curvature of the aortic arch: application of a novel stent graft to an aneurysm developing on a postoperative ductus arteriosus.

    Science.gov (United States)

    Soeda, Takeshi; Yokoi, Yoshihiko; Yuri, Koichi; Saito, Yuuhei; Setozaki, Shuji; Harada, Hisao

    2013-01-01

    A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient's whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.

  4. The Impact of Hospital’s Cardiac Specialization on Outcomes after Coronary Artery Bypass Graft Surgery: Analysis of Medicare Claims Data

    Science.gov (United States)

    Girotra, Saket; Lu, Xin; Popescu, Ioana; Vaughan-Sarrazin, Mary; Horwitz, Phillip A.; Cram, Peter

    2011-01-01

    Background Hospital volume has been widely embraced as a proxy measure for hospital quality; little attention has been focused on an alternative quality measure-hospital specialization. Even though specialization occurs on a continuum, previous studies have only focused on a small number of highly specialized hospitals (single-specialty hospitals). Studies on the broad relationship between hospital specialization and outcomes after coronary artery bypass grafting (CABG) are limited. Methods and Results We conducted a retrospective cohort study of 705,084 Medicare patients (1130 hospitals) who underwent CABG during 2001-2005. We stratified hospitals into quintiles based on their degree of cardiac specialization (proportion of a hospital’s Medicare discharges classified as Major Diagnostic Category 5 – cardiovascular diseases). We compared patient and hospital characteristics and outcomes across quintiles of cardiac specialization. Patient characteristics were generally similar across quintiles, but mean annual CABG volume increased progressively from quintile 1 (least-specialized) to quintile 5 (most-specialized). Unadjusted 30-day mortality was similar at hospitals in quintiles 1-4 (4.8%), except quintile 5 where mortality was lower (4.3%). A strong inverse association was seen between hospital cardiac specialization and 30-day mortality after adjustment for patient characteristics (P trend=0.001). However, this was no longer significant after additional adjustment for CABG volume (P trend=0.65). Results were similar for other mortality outcomes and length of stay. Conclusions After accounting for patient characteristics and CABG volume, greater cardiac specialization was not associated with clinically significant improvement in patient outcomes. This study calls into question the benefit of cardiac specialization for the vast majority of CABG-performing U.S. hospitals. PMID:20923993

  5. Fat grafting and breast reconstruction: tips for ensuring predictability.

    Science.gov (United States)

    Gabriel, Allen; Champaneria, Manish C; Maxwell, G Patrick

    2015-06-01

    Autologous fat grafting is widely used in breast surgery to refine and optimize aesthetic outcomes. Despite its widespread use, obtaining predictable, reliable, and consistent outcomes remains a significant challenge and is influenced by the technique used for procurement, processing, and placement of the fat. At present, there is no published consensus on the optimal technique. The purpose of this article is to review current techniques at each stage of fat grafting and provide tips on best practices based on the published literature as well as our extensive clinical experience.

  6. Chronologic changes of free fat graft in rabbit using CT

    International Nuclear Information System (INIS)

    Kondo, Norihiro; Kurita, Kenichi; Yajima, Tetsuya; Izumi, Masahiro

    2008-01-01

    Free fat grafts are now used for preventing osteal readhesion, filling dead space, and protecting grafted nerves and vessels. However, it is reported that grafted fat tissue is unstable resulting in high risk of cicatrization and infection. We grafted free fat to a rabbit's back and observed the chronologic change using CT. Ten adult male Japanese white rabbits (3.5 kg) were used. In five rabbits, fat tissue was obtained from the back under general anaesthesia, and transplanted into the back about 50 mm posterior from the donor site. CT was taken in the fixed scan condition five times (preoperation, immediate postoperation, postoperative 1-month, 2-month, and 3-month). In the remaining five rabbits, only CT scan was taken three times as a control. It was observed that we compared preoperative fat volume with the postoperative volume using RealINTAGE. Grafted fat tissue decreased postoperatively at 1-month and completely disappeared at 3-months. We were able to prove that CT scan is effective to observe the chronologic change of grafted fat tissue. Techniques of tissue engineering are necessary for survival of grafted fat tissue. (author)

  7. A Review on Grafting of Biofibers for Biocomposites.

    Science.gov (United States)

    Wei, Liqing; McDonald, Armando G

    2016-04-22

    A recent increase in the use of biofibers as low-cost and renewable reinforcement for the polymer biocomposites has been seen globally. Biofibers are classified into: lignocellulosic fibers ( i.e. , cellulose, wood and natural fibers), nanocellulose ( i.e. , cellulose nanocrystals and cellulose nanofibrils), and bacterial cellulose, while polymer matrix materials can be petroleum based or bio-based. Green biocomposites can be produced using both biobased fibers and polymers. Incompatibility between the hydrophilic biofibers and hydrophobic polymer matrix can cause performance failure of resulting biocomposites. Diverse efforts have focused on the modification of biofibers in order to improve the performances of biocomposites. "Grafting" copolymerization strategy can render the advantages of biofiber and impart polymer properties onto it and the performance of biocomposites can be tuned through changing grafting parameters. This review presents a short overview of various "grafting" methods which can be directly or potentially employed to enhance the interaction between biofibers and a polymer matrix for biocomposites. Major grafting techniques, including ring opening polymerization, grafting via coupling agent and free radical induced grafting, have been discussed. Improved properties such as mechanical, thermal, and water resistance have provided grafted biocomposites with new opportunities for applications in specific industries.

  8. Calf Contouring with Endoscopic Fascial Release, Calf Implant, and Structural Fat Grafting

    Directory of Open Access Journals (Sweden)

    Ercan Karacaoglu, MD

    2013-08-01

    Conclusions: A novel endoscopic approach for lower leg contouring is discussed. Endoscopic fasciotomy technique with calf implant and structural fat grafting for improved lower leg aesthetics is a simple, effective, reliable, and predictable technique for calf contouring.

  9. Plant-Damage Assessment Technique for Evaluating Military Vehicular Impacts to Vegetation in the Mojave Desert; TOPICAL

    International Nuclear Information System (INIS)

    D. J. Hansen; W. K. Ostler

    2001-01-01

    A new plant damage assessment technique was developed by plant ecologists from Bechtel Nevada at the U.S. Department of Energy's National Security Administration Nevada Operations Office and funded by the Strategic Environmental Research and Development Program Project CS-1131 in cooperation with the U.S. Army's National Training Center (NTC) at Fort Irwin, California. The technique establishes linear transects the width of vehicle tracts from evidence of vehicle tracks in the soil (usually during a prior training rotation period of 30 days or since the last rain or wind storm), and measures vegetation within the tracks to determine the area of plant parts being run over, the percent of the impacted parts damaged, and the percent of impacted parts expected to recover. It documents prior-damage classes based on estimated of damage that plants have apparently experienced previously (as assessed from field indicators of damage such as plant shape and height). The technique was used to evaluate different vehicle types (rubber-tire wheels vs. tracks) in six area at the NTC with different soils and training intensity levels. The technique provides tabular data that can be sorted and queried to show a variety of trends related to military vehicular impacts. The technique also appears suitable for assessing other non-military off-road traffic impacts. Findings report: (1) differences in plant sensitivity of different vehicular impacts, (2) plant cover and density by species and training area, (3) the degree to which wheels have less impact than tracks, and (4) the mean percent survival is inversely proportional to the degree of prior damage received by the vegetation (i.e., plants previously impacted have lower survival than plants not previously impacted)

  10. The adsorption of Pb(sup2+) and Cu(sup2+) onto gum ghatti-grafted poly(acrylamide-co-acrylonitrile) biodegradable hydrogel: isotherms and kinetic models

    CSIR Research Space (South Africa)

    Mittal, H

    2015-01-01

    Full Text Available A biodegradable hydrogel polymer of gum ghatti (Gg) with a copolymer mixture of acrylamide (AAm) and acrylonitrile (AN) was synthesized using the free-radical graft copolymerization technique. The effect of graft copolymerization on the surface area...

  11. Graft Copolymerization of Methyl Methacrylate Monomer onto Starch and Natural Rubber Latex Initiated by Gamma Irradiation

    Directory of Open Access Journals (Sweden)

    S. Iskandar

    2011-04-01

    Full Text Available To obtain the degradable plastic, the graft copolymerization of methyl methacrylate onto starch and natural rubber latex was conducted by a simultaneous irradiation technique. Gamma-ray from cobalt-60 source was used as the initiator. The grafted copolymer of starch-polymethyl methacrylate and the grafted copolymer of natural rubber-polymethyl methacrylate were mixed in the blender, and dried it in the oven. The dried grafted copolymer mixture was then molded using hydraulic press machine. The effect of irradiation dose, composition of the grafted copolymer mixture, film forming condition and recycle effect was evaluated. The parameters observed were tensile strength, gel fraction and soil burial degradability of grafted copolymer mixture. It was found that the tensile strength of grafted copolymer mixture increased by -ray irradiation. Increasing of the grafted copolymer of natural rubber-polymethyl methacrylate content, the gel fraction and tensile strength of the grafted copolymer mixture increased. The tensile strength of the grafted copolymer mixture was increased from 18 MPa to 23 MPa after recycled (film forming reprocessed 3 times. The grafted copolymer mixture was degraded completely after soil buried for 6 months

  12. Remote manipulation of posterior lamellar corneal grafts using a magnetic field.

    Science.gov (United States)

    Nahum, Yoav; Barliya, Tilda; Bahar, Irit; Livnat, Tami; Nisgav, Yael; Weinberger, Dov

    2013-06-01

    In posterior lamellar keratoplasty procedures such as Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty, the lamellar graft is manipulated directly or by injecting an air bubble. This preliminary study sought to evaluate the feasibility of guiding lamellar corneal grafts by generating a magnetic field. Rabbit and porcine Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty grafts were manually produced and immersed in a ferromagnetic solution containing nanomagnetic particles conjugated to streptavidin or in gadoteric acid. For the feasibility study, grafts were transferred to an artificial anterior chamber or plastic test tube and a magnetic field was generated with a handheld NdFeB disc magnet. The presence and the sustainability of graft motion were documented under various conditions. For the semiquantitative study, whole or partial grafts were transferred to a plastic test tube after immersion, and the amount of tissue retraction induced by the remote magnet was graded. The grafts were successfully manipulated in all directions by the magnet, from a distance of up to 7 mm. They remained ferromagnetic more than 24 hours after immersion in the ferromagnetic solutions. The degree of retraction was affected by graft size, immersion time, time from immersion, and immersion solution. Posterior lamellar corneal grafts may be made ferromagnetic and remotely manipulated by creation of a magnetic field. The ferromagnetic properties are adjustable. This technique holds promise in attaching and repositioning grafts during keratoplasty. Further research is needed to assess the possible effects of ferromagnetic solutions on corneal endothelial cells and on lamellar graft clarity.

  13. A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

    Directory of Open Access Journals (Sweden)

    Cem Inan Bektas

    2013-11-01

    Full Text Available BackgroundThe most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds.MethodsBetween March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm. First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion.ResultsThe mean follow-up was 7 months (range, 2-10 months in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent.ConclusionsIn our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

  14. Environmental application of radiation grafting

    International Nuclear Information System (INIS)

    Tamada, Masao

    2007-01-01

    Adsorbent having high selectivity against a certain metal ion was synthesized by means of radiation-induced graft polymerization for the purpose of environmental application. The resulting adsorbents were utilized for the removal of toxic metal from scallop waste and the collection of uranium from seawater. As a novel application of grafting, the biodegradability of poly-hydroxybutylate was controlled by grafting. The biodegradability could be depressed by the graft chain and then recovered by external stimuli such as thermal and chemical treatments. (author)

  15. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  16. Preparation of vinyl acetate grafted natural rubber by irradiation method

    Energy Technology Data Exchange (ETDEWEB)

    Porntrairat, A.; Pattamaprom, C. [Center of Excellence on Natural Rubber Technology, Department of Chemical Engineering, Faculty of Engineering, Thammasat University, Pathumthani 12120 (Thailand)

    2016-03-09

    Improvement in properties of natural rubber could be done by several methods. In this research, gamma radiation technique, which is simple, accurate, easy to control and clean, was applied to enhance the properties of natural rubber (NR) in latex state. The purpose of this research is to study the appropriate condition for preparing grafted natural rubber latex by using irradiation method. Vinyl acetate monomers (VAc) were grafted onto natural rubber latex (NR-g-PVAc) at 0-10 kGys by gamma radiation from Cobalt-60 source at room temperature. Physical properties of grafted natural rubber such as chloroform number, swelling ratio and gel content were measured. The VAc content of NR-g-PVAc was investigated by titration and visualized by FTIR spectroscopy. The FTIR spectra of NR-g-PVAc prepared at 0-10 kGys showed characteristic peaks of the vinyl acetate confirming that VAc could be grafted onto natural rubber molecular chains effectively under appropriate irradiation conditions. From the result, radiation grafting was found to be a useful technique for grafting of vinyl acetate onto natural rubber.

  17. The versatile subepithelial connective tissue graft: a literature update.

    Science.gov (United States)

    Karthikeyan, B V; Khanna, Divya; Chowdhary, Kamedh Yashawant; Prabhuji, M Lv

    2016-01-01

    Harmony between hard and soft tissue morphologies is essential for form, function, and a good esthetic outlook. Replacement grafts for correction of soft tissue defects around the teeth have become important to periodontal plastic and implant surgical procedures. Among a multitude of surgical techniques and graft materials reported in literature, the subepithelial connective tissue graft (SCTG) has gained wide popularity and acceptance. The purpose of this article is to acquaint clinicians with the current understanding of the versatile SCTG. Key factors associated with graft harvesting as well as applications, limitations, and complications of SCTGs are discussed. This connective tissue has shown excellent short- and long-term stability, is easily available, and is economical to use. The SCTG should be considered as an alternative in all periodontal reconstruction surgeries.

  18. Bladder Mucosal Graft Vaginoplasty: A Case Report.

    Science.gov (United States)

    Chiaramonte, Cinzia; Vestri, Elettra; Tripi, Flavia; Giannone, Antonino Giulio; Cimador, Marcello; Cataliotti, Ferdinando

    2018-06-18

    Female vaginoplasty reconstruction, by choice, is usually performed with adjacent tissue. However in some clinical conditions such as high urogenital confluence sinus, cloacal malformation with extreme vaginal hypoplasia, local tissue may not be available. When vaginal replacement is performed in pediatric patients intestinal segments is preferred to non-operative procedures that require continuative dilations. However mucus production, malignant transformation risk and diversion colitis are important side effects. We present a nouvel technique for vaginoplasty in a female child presenting with an isolated urogenital sinus malformation without virilization. The patient at 20 months underwent vaginoplasty using tubularized bladder mucosal graft. Surgical procedure was devoid of complications. Pubertal development occurred at age of 15. She underwent regular follow up until 18 years of age. At this age we performed clinical evaluation: absence of vaginal introitus stenosis and good cosmetic results were observed. Then she underwent vaginoscopy with multiple biopsies. Pathology examination of the bladder mucosal graft evidenced a normal structure of the mucosa, with a stratified squamous epithelium. Different techniques are taken into account for vaginal reconstruction according to the severity and to the type of malformation. We describe the use of bladder mucosal graft with favorable results after long term follow-up. Copyright © 2018. Published by Elsevier Inc.

  19. Monitoring and Modeling the Impact of Grazers Using Visual, Remote and Traditional Field Techniques

    Science.gov (United States)

    Roadknight, C. M.; Marshall, I. W.; Rose, R. J.

    2009-04-01

    The relationship between wild and domestic animals and the landscape they graze upon is important to soil erosion studies because they are a strong influence on vegetation cover (a key control on the rate of overland flow runoff), and also because the grazers contribute directly to sediment transport via carriage and indirectly by exposing fresh soil by trampling and burrowing/excavating. Quantifying the impacts of these effects on soil erosion and their dependence on grazing intensity, in complex semi-natural habitats has proved difficult. This is due to lack of manpower to collect sufficient data and weak standardization of data collection between observers. The advent of cheaper and more sophisticated digital camera technology and GPS tracking devices has lead to an increase in the amount of habitat monitoring information that is being collected. We report on the use of automated trail cameras to continuously capture images of grazer (sheep, rabbits, deer) activity in a variety of habitats at the Moor House nature reserve in northern England. As well as grazer activity these cameras also give valuable information on key climatic soil erosion factors such as snow, rain and wind and plant growth and thus allow the importance of a range of grazer activities and the grazing intensity to be estimated. GPS collars and more well established survey methods (erosion monitoring, dung counting and vegetation surveys) are being used to generate a detailed representation of land usage and plan camera siting. This paper describes the data collection techniques, outlines the quantitative and qualitative data collected and proposes online and offline systems that can reduce the data processing time and increase focus on important subsets in the collected data. We also present a land usage model that estimates grazing intensity, grazer behaviours and their impact on soil coverage at sites where cameras have not been deployed, based on generalising from camera sites to other

  20. Impact of robotic technique and surgical volume on the cost of radical prostatectomy.

    Science.gov (United States)

    Hyams, Elias S; Mullins, Jeffrey K; Pierorazio, Phillip M; Partin, Alan W; Allaf, Mohamad E; Matlaga, Brian R

    2013-03-01

    Our present understanding of the effect of robotic surgery and surgical volume on the cost of radical prostatectomy (RP) is limited. Given the increasing pressures placed on healthcare resource utilization, such determinations of healthcare value are becoming increasingly important. Therefore, we performed a study to define the effect of robotic technology and surgical volume on the cost of RP. The state of Maryland mandates that all acute-care hospitals report encounter-level and hospital discharge data to the Health Service Cost Review Commission (HSCRC). The HSCRC was queried for men undergoing RP between 2008 and 2011 (the period during which robot-assisted laparoscopic radical prostatectomy [RALRP] was coded separately). High-volume hospitals were defined as >60 cases per year, and high-volume surgeons were defined as >40 cases per year. Multivariate regression analysis was performed to evaluate whether robotic technique and high surgical volume impacted the cost of RP. There were 1499 patients who underwent RALRP and 2565 who underwent radical retropubic prostatectomy (RRP) during the study period. The total cost for RALRP was higher than for RRP ($14,000 vs 10,100; Probotic surgery has come to dominate the healthcare marketplace, strategies to increase the role of high-volume providers may be needed to improve the cost-effectiveness of prostate cancer surgical therapy.

  1. Impact of extraction techniques on antioxidant capacities and phytochemical composition of polyphenol-rich extracts.

    Science.gov (United States)

    Castro-López, Cecilia; Ventura-Sobrevilla, Janeth M; González-Hernández, María D; Rojas, Romeo; Ascacio-Valdés, Juan A; Aguilar, Cristóbal N; Martínez-Ávila, Guillermo C G

    2017-12-15

    In this work, impact of extraction methods (maceration, decoction, MAE, and UAE) on TPC, antioxidant activity, and the mass fraction of phenolics in several plant extracts (Punica granatum, Juglans regia, Moringa oleifera, and Cassia fistula) was investigated. The results showed that, despite the nature of matrix, the highest values of TPC in all samples were obtained by MAE as follows: PP (18.92±0.11), ML (15.19±0.11), HL (12.69±0.16), and WS (12.80±0.11) mg GAEg -1 respectively, and exhibited potent antioxidant activity (from 0.28±0.01 to 5.34±0.02mgGAEg -1 ), representing sources of powerful antioxidants. The LC-MS 2 analysis revealed a wide range of phenolics, highlighting their content in phenolic acids, flavonoids and lignans. The presence of different phenol molecules demonstrated that the extraction method had influence on phytochemical profile. Finally, due to its high extraction efficiency, MAE was the more effective extraction technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Dosimetric Impact of Primary Planning Parameters in Dynamic Conformal Arc Technique for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Yeon; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Si Yong [Dept. of Radiation Oncology, Mayo Clinic, Jacksonvile (United States); Lee, Jeong Woo [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung Sik [Dept. of Radiation Oncology, Anyang SAM Hospital, Anyang (Korea, Republic of)

    2011-04-15

    As one of the stereotactic body radiation therapy (SBRT) techniques, dynamic conformal arc therapy (DCAT) is commonly adopted to efficiently deliver conformal doses. However, as the DCAT uses numerous beams at individual control points, the dosimetric errors generated from each beam can be accumulated and manifested. In SBRT, therefore, due to the high fractional dose within a few fractions to moving target, the determination of the applied plan parameters can be critical and the evaluation of dosimetric impact of planning parameters would play an important role in DCAT planning process. In this study, we systematically evaluated the dosimetric influence caused by the variable grid size and the angular increment in DCAT for lung SBRT. Dose variations with different parameters were estimated for spherical and elongated tumors on an anthropomorphic phantom. The systematic analysis of the generated dose variation would guide to determine appropriate plan parameters and to estimate the dose errors in planning process in a clinical perspective of DCAT. It was found that two plan parameters, grid size and angular increment, in DCAT could cause non-negligible dose uncertainty. Coarse grid size led patients to get unnecessary overdose. Coarse angular increment could make significantly inaccurate prediction of OAR dose, resulting in either over- or under- estimation depending on the location of OAR relative to the isocenter.

  3. Value impact analysis utilizing PRA techniques combined with a hybrid plant model

    International Nuclear Information System (INIS)

    Edson, J.L.; Stillwell, D.W.

    1989-01-01

    A value impact analysis (VIA) has been performed by the INEL to support a NRC Regulatory Analysis for resolution of Generic Issue (GI) 29, Bolting Degradation or Failure in Nuclear Power Plants. A VIA for replacing the reactor coolant pressure boundary (RCPB) bolts of BWRs and PWRs was previously prepared by Pacific Northwest Laboratories in 1985 under instructions limiting the VIA to the potential for failure of primary pressure boundary bolting. Subsequently the INEL was requested to perform a VIA that included non primary systems and component support bolts to be compatible with the resolution of the broader issue. Because the initial list of systems and bolting applications that could be included in the VIA was very large, including them all in the VIA would likely result in analyzing some that have little if any effect on public risk. This paper discusses how PRA techniques combined with a hybrid plant model were used to determine which bolts have the potential to be significant contributors to public risk if they were to fail, and therefore were included in the VIA

  4. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  5. A Simple Ensemble Simulation Technique for Assessment of Future Variations in Specific High-Impact Weather Events

    Science.gov (United States)

    Taniguchi, Kenji

    2018-04-01

    To investigate future variations in high-impact weather events, numerous samples are required. For the detailed assessment in a specific region, a high spatial resolution is also required. A simple ensemble simulation technique is proposed in this paper. In the proposed technique, new ensemble members were generated from one basic state vector and two perturbation vectors, which were obtained by lagged average forecasting simulations. Sensitivity experiments with different numbers of ensemble members, different simulation lengths, and different perturbation magnitudes were performed. Experimental application to a global warming study was also implemented for a typhoon event. Ensemble-mean results and ensemble spreads of total precipitation, atmospheric conditions showed similar characteristics across the sensitivity experiments. The frequencies of the maximum total and hourly precipitation also showed similar distributions. These results indicate the robustness of the proposed technique. On the other hand, considerable ensemble spread was found in each ensemble experiment. In addition, the results of the application to a global warming study showed possible variations in the future. These results indicate that the proposed technique is useful for investigating various meteorological phenomena and the impacts of global warming. The results of the ensemble simulations also enable the stochastic evaluation of differences in high-impact weather events. In addition, the impacts of a spectral nudging technique were also examined. The tracks of a typhoon were quite different between cases with and without spectral nudging; however, the ranges of the tracks among ensemble members were comparable. It indicates that spectral nudging does not necessarily suppress ensemble spread.

  6. Hemodynamic analysis of sequential graft from right coronary system to left coronary system.

    Science.gov (United States)

    Wang, Wenxin; Mao, Boyan; Wang, Haoran; Geng, Xueying; Zhao, Xi; Zhang, Huixia; Xie, Jinsheng; Zhao, Zhou; Lian, Bo; Liu, Youjun

    2016-12-28

    Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

  7. Composite vascular grafts with high cell infiltration by co-electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Zhikai, E-mail: tanzk@hnu.edu.cn; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-10-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  8. Composite vascular grafts with high cell infiltration by co-electrospinning

    International Nuclear Information System (INIS)

    Tan, Zhikai; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-01-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  9. The Use of Grafting to Study Systemic Signaling in Plants.

    Science.gov (United States)

    Tsutsui, Hiroki; Notaguchi, Michitaka

    2017-08-01

    Grafting has long been an important technique in agriculture. Nowadays, grafting is a widely used technique also to study systemic long-distance signaling in plants. Plants respond to their surrounding environment, and at that time many aspects of their physiology are regulated systemically; these start from local input signals and are followed by the transmission of information to the rest of the plant. For example, soil nutrient conditions, light/photoperiod, and biotic and abiotic stresses affect plants heterogeneously, and plants perceive such information in specific plant tissues or organs. Such environmental cues are crucial determinants of plant growth and development, and plants drastically change their morphology and physiology to adapt to various events in their life. Hitherto, intensive studies have been conducted to understand systemic signaling in plants, and grafting techniques have permitted advances in this field. The breakthrough technique of micrografting in Arabidopsis thaliana was established in 2002 and led to the development of molecular genetic tools in this field. Thereafter, various phenomena of systemic signaling have been identified at the molecular level, including nutrient fixation, flowering, circadian clock and defense against pathogens. The significance of grafting is that it can clarify the transmission of the stimulus and molecules. At present, many micro- and macromolecules have been identified as mobile signals, which are transported through plant vascular tissues to co-ordinate their physiology and development. In this review, we introduce the various grafting techniques that have been developed, we report on the recent advances in the field of plant systemic signaling where grafting techniques have been applied and provide insights for the future. © The Author 2017. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  10. Potential impact of tsetse fly control involving the sterile insect technique

    International Nuclear Information System (INIS)

    Feldmann, U.; Dyck, V.A.; Mattioli, R.C.; Jannin, J.

    2005-01-01

    sterile insect technique (SIT), as a component of area-wide integrated pest management (AW-IPM) programmes to create tsetse-free zones, has been demonstrated in Zanzibar and other locations. This chapter (1) outlines the causal relationship between the T and T problem and food insecurity, malnutrition, poverty, and related disease and development constraints, (2) describes the impact of the problem on African rural communities and the overall economy, and (3) indicates the potential benefits of a reduced T and T burden, or even of its zonal elimination from selected priority areas in support of sustainable rural development. (author)

  11. In vivo biodistribution and biological impact of injected carbon nanotubes using magnetic resonance techniques

    Directory of Open Access Journals (Sweden)

    Achraf Al Faraj

    2011-02-01

    Full Text Available Achraf Al Faraj1,2, Florence Fauvelle3, Nathalie Luciani4, Ghislaine Lacroix5, Michael Levy4, Yannick Crémillieux1, Emmanuelle Canet-Soulas1Université Lyon1, Créatis-LRMN, Lyon, France; 2King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, Riyadh, Kingdom of Saudi Arabia; 3CRSSA, Biophysique Cellulaire et Moléculaire, Laboratoire de RMN, La Tronche, France; 4Université Paris7-Paris Diderot, Matières et Systèmes Complexes, Paris, France; 5Institut National de l’Environnement et des Risques Industriels, Verneuil-en-Halatte, FranceBackground: Single-walled carbon nanotubes (SWCNT hold promise for applications as contrast agents and target delivery carriers in the field of nanomedicine. When administered in vivo, their biodistribution and pharmacological profile needs to be fully characterized. The tissue distribution of carbon nanotubes and their potential impact on metabolism depend on their shape, coating, and metallic impurities. Because standard radiolabeled or fluorescently-labeled pharmaceuticals are not well suited for long-term in vivo follow-up of carbon nanotubes, alternative methods are required.Methods: In this study, noninvasive in vivo magnetic resonance imaging (MRI investigations combined with high-resolution magic angle spinning (HR-MAS, Raman spectroscopy, iron assays, and histological analysis ex vivo were proposed and applied to assess the biodistribution and biological impact of intravenously injected pristine (raw and purified and functionalized SWCNT in a 2-week longitudinal study. Iron impurities allowed raw detection of SWCNT in vivo by susceptibility-weighted MRI.Results: A transitional accumulation in the spleen and liver was observed by MRI. Raman spectroscopy, iron assays, and histological findings confirmed the MRI readouts. Moreover, no acute toxicological effect on the liver metabolic profile was observed using the HR-MAS technique, as confirmed by quantitative real

  12. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  13. Use of Behavioral Disciplinary Techniques with the Implementation of SWPBIS and Its Impact on Students' Prosocial Motivation

    Science.gov (United States)

    Blank, Jessica C.

    2013-01-01

    This study was aimed to investigate the potential negative impact that positive (e.g., praise and rewards) and punitive (e.g., sending students to the office) disciplinary techniques, commonly used within the Schoolwide Positive Behavioral Interventions and Supports (SWPBIS) approach, have on students' prosocial motivation, and how aspects of…

  14. Thermodynamic assessment of impact of inlet air cooling techniques on gas turbine and combined cycle performance

    International Nuclear Information System (INIS)

    Mohapatra, Alok Ku; Sanjay

    2014-01-01

    The article is focused on the comparison of impact of two different methods of inlet air cooling (vapor compression and vapor absorption cooling) integrated to a cooled gas turbine based combined cycle plant. Air-film cooling has been adopted as the cooling technique for gas turbine blades. A parametric study of the effect of compressor pressure ratio, compressor inlet temperature (T i , C ), turbine inlet temperature (T i , T ), ambient relative humidity and ambient temperature on performance parameters of plant has been carried out. Optimum T i , T corresponding to maximum plant efficiency of combined cycle increases by 100 °C due to the integration of inlet air cooling. It has been observed that vapor compression cooling improves the efficiency of gas turbine cycle by 4.88% and work output by 14.77%. In case of vapor absorption cooling an improvement of 17.2% in gas cycle work output and 9.47% in gas cycle efficiency has been observed. For combined cycle configuration, however, vapor compression cooling should be preferred over absorption cooling in terms of higher plant performance. The optimum value of compressor inlet temperature has been observed to be 20 °C for the chosen set of conditions for both the inlet air cooling schemes. - Highlights: • Inlet air cooling improves performance of cooled gas turbine based combined cycle. • Vapor compression inlet air cooling is superior to vapor absorption inlet cooling. • For every turbine inlet temperature, there exists an optimum pressure ratio. • The optimum compressor inlet temperature is found to be 293 K

  15. Monitoring techniques for the impact assessment during nuclear and radiological emergencies: current status and the challenges

    International Nuclear Information System (INIS)

    Pradeepkumar, K.S.; Sharma, D.N.

    2003-01-01

    Preparedness and response capability for Nuclear and Radiological emergencies, existing world over, are mainly based on the requirement of responding to radiation emergency caused by nuclear or radiological accidents. Cosmos satellite accident, plutonium contamination at Polaris, nuclear accidents like Kystium, Windscale, TMI and Chernobyl, radiological accidents at Goiania etc have demonstrated the requirement of improved radiation monitoring techniques. For quick decision making, state of the art monitoring methodology which can support quantitative and qualitative impact assessment is essential. Evaluation of radiological mapping of the area suspected to be contaminated needs ground based as well as aerial based monitoring systems to predict the level of radioactive contamination on ground. This will help in delineating the area and deciding the required countermeasures, based on the quantity and type of radionuclides responsible for it. The response can be successful with the effective use of i) Early Warning System ii) Mobile Monitoring System and iii) Aerial Gamma Spectrometric System. Selection of the monitoring methodology and survey parameters and assessment of situation using available resources etc. are to be optimized depending on the accident scenario. Recently, many countries and agencies like IAEA have expressed the requirement for responding to other types of nuclear/radiological emergencies i.e, man made radiation emergency situations aimed at harming public at large that can also lead to environmental contamination and significant exposure to public. Reports of lost / misplaced / stolen radioactive sources from many countries are alarming as safety and security of these radioactive sources are under challenge. The monitoring methodology has to take into account of the increase in such demands and more periodic monitoring in suspected locations is to be carried out. Detection of orphan sources possible amidst large heap of metallic scraps may pose

  16. High Rate Micromechanical Behavior of Grafted Polymer Nanoparticle Films

    Science.gov (United States)

    Thomas, Edwin

    We report the ultra high strain rate behavior of films comprised of polymer grafted nanoparticles (NPs) and compare the results to homopolymer films. The films are formed by flow coating a suspension of polystyrene (PS) chains of 230 kg/mol grafted to 16nm diameter SiO2\\ at a graft density of 0.6 chains/nm2 resulting a film with 1 vol % SiO2. Films of 267 kg/mol PS were also flow coated and both films were impacted at velocities 350-700 ms-1 using 3.7 micron SiO2\\ projectiles to achieve increments in kinetic energy (KE) of 1:2:4. The KE of the projectiles before and after penetration was measured to determine the penetration energy. TEM and SEM suggest the projectile initially induces plastic flow due to the adiabatic temperature rise from impact. As the projectile deforms the film, the lower magnitude, biaxial stress state in the peripherial regions causes material microvoid formation and initiation of craze growth in the radial and tangential directions. The anchoring of the grafted polymer chains to the NPs increases the penetration energy relative to the pure homopolymer by 50% and the films capacity to delocalize the impact by 200%. These results suggest that highly grafted NP films may be useful in lightweight protection systems. In collaboration with Omri Fried, Olawale Lawal, Yang Jiao, Victor Hsaio, Thevamaran Ramathasan, Mujin Zhou, Richard Vaia.

  17. Blood compatibility of AAc, HEMA, and PEGMA-grafted cellulose film

    International Nuclear Information System (INIS)

    Nho, Young Chang.; Kwon, Oh Hyun

    2003-01-01

    To improve surface blood compatibility on cellulose film for hemodialysis, acrylic acid, 2-hydroxyethyl methacrylate and three kinds of polyethylene glycol methacrylates were grafted onto the cellulose film surface by radiation grafting technique. Heparin was introduced onto the grafted cellulose film surfaces. The grafting and heparinization were confirmed by Fourier transform infrared spectroscopy in the attenuated total reflectance mode and electron spectroscopy for chemical analysis. The blood compatibility of the modified cellulose film was examined by the determination of platelet adhesion and thrombus formation

  18. Colored polyethylene soil covers and grafting effects on cucumber flowering and yield

    Directory of Open Access Journals (Sweden)

    Fonseca Inês Cristina de Batista

    2003-01-01

    Full Text Available Cucumber (Cucumis sativus L. is one of the most cultivated vegetable crops in plastic greenhouses in Brazil because of the short cycle and its high economic value in off-season harvests. To better understand this management technique the effect of different colored polyethylene soil covers was evaluated in relation to flowering and yield of the hybrid cucumber 'Yoshinari' grafted or not on the hybrid squash 'Ikky'. The polyethylene cover colors were black, white on black and green plus a control without cover. Covered but not grafted crops had a more uniform flowering distribution. The number of flowers was greater for the white/black grafted treatment. All the polyethylene covers favored flowering for the non grafted plants. Grafting reduced flowering for the black or green polyethylene covers treatments. The fruit set increased with the use of polyethylene cover but was not influenced by grafting. The uniform distribution of flowering remained during fruiting only for grafted plants and soil covered with black or green polyethylene. Both polyethylene cover and grafting favored early harvesting. The 'Yoshinari'/'Ikky' graft caused taller plants but fruit were thicker and smaller and did not meet the commercial standard. The best quality fruit and highest yields were obtained in the black and white/black treatments, without grafting.

  19. Electron beam induced graft-polymerization of methyl methacrylate onto polyethylene films at high dose rates

    International Nuclear Information System (INIS)

    Mori, Koji; Koshiishi, Kenji; Masuhara, Ken-ichi

    1991-01-01

    Electron beam induced graft-polymerization by the mutual irradiation technique of methyl methacrylate on the surface of low density polyethylene films (LD) and high density polyethylene films (HD) was investigated at high dose rates over 10 Mrad per second. Graft-polymerization mechanisms were discussed on the basis of O 2 permeability, tensile strength, elongation at break, and surface tension of the grafted films. As the degree of grafting increased, the O 2 permeability of LD decreased, while that of HD little changed at the grafting up to 4 ∼ 5 %. This indicates that the grafting occurred in the amorphous regions for LD and occurred in the amorphous regions in the neighborhood of crystalline regions for HD. For HD, when the degree of the grafting surpassed 4 ∼ 5 %, the O 2 permeability, tensile strength, elongation at break, and surface tension decreased with an increase in the degree of grafting. It was assumed that rapid grafting in the amorphous regions in the neighborhood of crystalline regions caused the increase in local temperature by the heat of polymerization, and the viscosity of polyethylene in the amorphous regions decreased with an increase in temperature. As a result, the graft chains, which formed micro domain structure, condensed in the amorphous regions and the domain increased in size. (author)

  20. Defluoridation potential of jute fibers grafted with fatty acyl chain

    Energy Technology Data Exchange (ETDEWEB)

    Manna, Suvendu; Saha, Prosenjit [Materials Science Centre, IIT Kharagpur, WB 721302 (India); Roy, Debasis, E-mail: debasis@civil.iitkgp.ernet.in [Department of Civil Engineering, IIT Kharagpur, WB 721302 (India); Sen, Ramkrishna [Department of Biotechnology, IIT Kharagpur, WB 721302 (India); Adhikari, Basudam [Materials Science Centre, IIT Kharagpur, WB 721302 (India)

    2015-11-30

    Graphical abstract: - Highlights: • Acyl chain grafted jute has been shown to accumulate fluoride ions. • Covalent and hydrogen bonding and protonation were the contributing factors. • The process is relatively inexpensive and maintenance-free. • Acyl chain grafted jute showed higher fluoride ions accumulation than alternatives. - Abstract: Waterborne fluoride is usually removed from water by coagulation, adsorption, ion exchange, electro dialysis or reverse osmosis. These processes are often effective over narrow pH ranges, release ions considered hazardous to human health or produce large volumes of toxic sludge that are difficult to handle and dispose. Although plant matters have been shown to remove waterborne fluoride, they suffer from poor removal efficiency. Following from the insight that interaction between microbial carbohydrate biopolymers and anionic surfaces is often facilitated by lipids, an attempt has been made to enhance fluoride adsorption efficiency of jute by grafting the lignocellulosic fiber with fatty acyl chains found in vegetable oils. Fluoride removal efficiency of grafted jute was found to be comparable or higher than those of alternative defluoridation processes. Infrared and X-ray photoelectron spectroscopic evidence indicated that hydrogen bonding, protonation and C−F bonding were responsible for fluoride accumulation on grafted jute. Adsorption based on grafted jute fibers appears to be an economical, sustainable and eco-friendly alternative technique for removing waterborne fluoride.

  1. Grafting of gold nanoparticles on polyethyleneterephthalate using dithiol interlayer

    International Nuclear Information System (INIS)

    Reznickova, A.; Kolska, Z.; Zaruba, K.; Svorcik, V.

    2014-01-01

    Two different procedures of grafting of polyethyleneterephthalate (PET), modified by plasma treatment, with gold nanoparticles (nanospheres) are studied. In the first procedure the PET foil was grafted with biphenyl-4,4′-dithiol and subsequently with gold nanoparticles. In the second one the PET foil was grafted with gold nanoparticles previously coated by the same dithiol. X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and electrokinetic analysis were used for characterization of the polymer surface at different modification steps. Gold nanoparticles were characterized by ultraviolet–visible spectroscopy. The first procedure was found to be more effective. It was proved that the dithiol was chemically bonded to the surface of the plasma activated PET and it mediates subsequent grafting of the gold nanoparticles. - Highlights: • Two different techniques were used for coating of PET with gold nanoparticles. • Grafted GNPs were characterized by XPS, FTIR, UV–vis, zeta potential, AFM. • More effective coating is achieved by deposition of GNPs earlier grafted with thiol. • The studied structures may have potential application in electronics or biomedicine

  2. Scarless abdominal fat graft harvest for neurosurgical procedures: technical note.

    Science.gov (United States)

    Trinh, Victoria T; Duckworth, Edward A M

    2015-02-01

    Background Abdominal fat grafts are often harvested for use in skull base reconstruction and cerebrospinal fluid (CSF) leak repairs, and for operations traversing the nasal sinuses or mastoid bone. Although the endoscopic transnasal surgery has gained significant popularity, in part because it is considered "scarless," a common adjunct, the abdominal fat graft, can result in a disfiguring scar across the abdomen. Objective This is the first report of a scarless abdominal fat graft technique for skull base reconstruction. Methods Ten patients with a median age of 56.5 years (range: 45-73 years) underwent endoscopic transsphenoidal tumor resection with intraumbilical fat graft harvest. Careful circumferential fat dissection at the umbilicus, with progressive retraction of the graft, was crucial to ensure maximal visualization and to prevent injury to the subcutaneous vessels and rectus fascia. Results Following reconstruction of the sellar skull base, all patients did well postoperatively with no evidence of CSF leak. At 12-week follow-up for all patients, there was no evidence of scar, intracavity hematoma, or wound infection. Conclusions Fat graft harvest through an intraumbilical incision results in a scar-free abdominal harvest, and is a useful procedural adjunct to complement "scarless" brain surgery.

  3. Calculations for reproducible autologous skin cell-spray grafting.

    Science.gov (United States)

    Esteban-Vives, Roger; Young, Matthew T; Zhu, Toby; Beiriger, Justin; Pekor, Chris; Ziembicki, Jenny; Corcos, Alain; Rubin, Peter; Gerlach, Jörg C

    2016-12-01

    Non-cultured, autologous cell-spray grafting is an alternative to mesh grafting for larger partial- and deep partial-thickness burn wounds. The treatment uses a suspension of isolated cells, from a patient's donor site skin tissue, and cell-spray deposition onto the wound that facilitates re-epithelialization. Existing protocols for therapeutic autologous skin cell isolation and cell-spray grafting have defined the donor site area to treatment area ratio of 1:80, substantially exceeding the coverage of conventional mesh grafting. However, ratios of 1:100 are possible by maximizing the wound treatment area with harvested cells from a given donor site skin tissue according to a given burn area. Although cell isolation methods are very well described in the literature, a rational approach addressing critical aspects of these techniques are of interest in planning clinical study protocols. We considered in an experimental study the cell yield as a function of the donor site skin tissue, the cell density for spray grafting, the liquid spray volume, the sprayed distribution area, and the percentage of surface coverage. The experimental data was then used for the development of constants and mathematical equations to give a rationale for the cell isolation and cell-spray grafting processes and in planning for clinical studies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  4. Vascularized pedicle jejunal graft for closure of large duodenal defect in a dog.

    Science.gov (United States)

    Massie, Anna; McFadden, Michael

    2016-11-01

    A Labrador retriever dog was presented for intestinal obstruction resulting in devitalization of portions of the duodenum. A severe perforation, accounting for 70% duodenal circumference, was present at the level of the duodenal papilla. A vascularized jejunal graft was used to close the perforation, representing novel utilization of this grafting technique.

  5. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  6. Piezoelectric Versus Conventional Rotary Techniques for Impacted Third Molar Extraction: A Meta-analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Jiang, Qian; Qiu, Yating; Yang, Chi; Yang, Jingyun; Chen, Minjie; Zhang, Zhiyuan

    2015-10-01

    Impacted third molars are frequently encountered in clinical work. Surgical removal of impacted third molars is often required to prevent clinical symptoms. Traditional rotary cutting instruments are potentially injurious, and piezosurgery, as a new osteotomy technique, has been introduced in oral and maxillofacial surgery. No consistent conclusion has been reached regarding whether this new technique is associated with fewer or less severe postoperative sequelae after third molar extraction.The aim of this study was to compare piezosurgery with rotary osteotomy techniques, with regard to surgery time and the severity of postoperative sequelae, including pain, swelling, and trismus.We conducted a systematic literature search in the Cochrane Library, PubMed, Embase, and Google Scholar.The eligibility criteria of this study included the following: the patients were clearly diagnosed as having impacted mandibular third molars; the patients underwent piezosurgery osteotomy, and in the control group rotary osteotomy techniques, for removing impacted third molars; the outcomes of interest include surgery time, trismus, swelling or pain; the studies are randomized controlled trials.We used random-effects models to calculate the difference in the outcomes, and the corresponding 95% confidence interval. We calculated the weighted mean difference if the trials used the same measurement, and a standardized mean difference if otherwise.A total of seven studies met the eligibility criteria and were included in our analysis. Compared with rotary osteotomy, patients undergoing piezosurgery experienced longer surgery time (mean difference 4.13 minutes, 95% confidence interval 2.75-5.52, P piezosurgery groups.The number of included randomized controlled trials and the sample size of each trial were relatively small, double blinding was not possible, and cost analysis was unavailable due to a lack of data.Our meta-analysis indicates that although patients undergoing piezosurgery

  7. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  8. Responses of grafted tomato (Solanum lycopersiocon L. to abiotic stresses in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulaziz Al-Harbi

    2017-09-01

    Full Text Available Quantity and quality of irrigation water are considered the most imperative limiting factors for plant production in arid environment. Adoptions of strategies can minimize crop water consumption while nonexistent yield reduction is considered challenge for scholars especially in arid environment. Grafting is regarded as a promising tool to avoid or reduce yield loss caused by abiotic stresses. Tomato (Solanum lycopersium Mill., commercial cultivar Faridah was grafted on Unifort rootstock and grown under regulated deficit irrigation (RDI (100%, 80% and 60% ETc, using two types of irrigation water, fresh (EC = 0.86 dS/m and brackish (EC = 3.52 dS/m. The effects of grafting and RDI on water use efficiency, vegetative growth, yield, fruit quality were investigated. Plant vegetative growth was reduced under water and salinity stresses. Grafting the plant significantly improves the vegetative growth under both conditions. The results showed that crop yield, Ca+2 and K+ were considerably increased in grafted tomato compared to non-grafted plants under water and salinity stresses. Grafted tomato plants accumulated less Na+ and Cl−, especially under high levels of salinity compared to non-grafted plants. Grafting tomato plants showed a slight decrease on the fruit quality traits such as vitamin C, titratable acidity (TA and total soluble solids (TSS. This study confirmed that grafted tomato plants can mitigate undesirable impact of salt stress on growth and fruit quality.

  9. Impact of the Z potential technique on reducing the sperm DNA fragmentation index, fertilization rate and embryo development.

    Science.gov (United States)

    Duarte, Carlos; Núñez, Víctor; Wong, Yat; Vivar, Carlos; Benites, Elder; Rodriguez, Urso; Vergara, Carlos; Ponce, Jorge

    2017-12-01

    In assisted reproduction procedures, we need to develop and enhance new protocols to optimize sperm selection. The aim of this study is to evaluate the ability of the Z potential technique to select sperm with intact DNA in non-normospermic patients and evaluate the impact of this selection on embryonic development. We analyzed a total of 174 human seminal samples with at least one altered parameter. We measured basal, post density gradients, and post density gradients + Z potential DNA fragmentation index. To evaluate the impact of this technique on embryo development, 54 cases were selected. The embryo development parameters evaluated were fertilization rate, cleavage rate, top quality embryos at the third day and blastocysts rate. We found significant differences in the study groups when we compared the sperm fragmentation index by adding the Z potential technique to density gradient selection vs. density gradients alone. Furthermore, there was no significant difference in the embryo development parameters between the low sperm fragmentation index group vs. the moderate and high sperm fragmentation index groups, when selecting sperms with this new technique. The Z potential technique is a very useful tool for sperm selection; it significantly reduces the DNA fragmentation index and improves the parameters of embryo development. This technique could be considered routine for its simplicity and low cost.

  10. Radiation Induced Grafting of Acrylate onto Waste Rubber: The Effect of Monomer Type

    Directory of Open Access Journals (Sweden)

    Shirajuddin Siti Salwa M.

    2017-01-01

    Full Text Available The effect of three different acrylate group monomers, namely n-butyl acrylate, methacrylic acid and tripropylene glycol diacrylate of radiation induced grafting onto waste rubber was studied. The electron beam accelerator operated at voltage of 2MeV was used to irradiate the waste rubber at 10 kGy and 100 kGy absorbed radiation dose, respectively. The formation of grafting was observed from the increase in the grafting yield and confirmed by Transformed Infra-Red Spectroscopy results. According to the result obtained, only tripropylene glycol diacrylate was selected to graft onto waste rubber. The carbonyl bond from acrylate groups was seen at 1726 cm-1 band which confirmed the presence of TPGDA in the polymer matrix. This indicates the successful preparation of the TPGDA-grafted waste rubber via radiation induced grafting techniques.

  11. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  12. An External Wire Frame Fixation Method of Skin Grafting for Burn Reconstruction.

    Science.gov (United States)

    Yoshino, Yukiko; Ueda, Hyakuzoh; Ono, Simpei; Ogawa, Rei

    2017-06-28

    The skin graft is a prevalent reconstructive method for burn injuries. We have been applying external wire frame fixation methods in combination with skin grafts since 1986 and have experienced better outcomes in percentage of successful graft take. The overall purpose of this method was to further secure skin graft adherence to wound beds in hard to stabilize areas. There are also location-specific benefits to this technique such as eliminating the need of tarsorrhaphy in periorbital area, allowing immediate food intake after surgery in perioral area, and performing less invasive fixing methods in digits, and so on. The purpose of this study was to clarify its benefits and applicable locations. We reviewed 22 postburn patients with skin graft reconstructions using the external wire frame method at our institution from December 2012 through September 2016. Details of the surgical technique and individual reports are also discussed. Of the 22 cases, 15 (68%) were split-thickness skin grafts and 7 (32%) were full-thickness skin grafts. Five cases (23%) involved periorbital reconstruction, 5 (23%) involved perioral reconstruction, 2 (9%) involved lower limb reconstruction, and 10 (45%) involved digital reconstruction. Complete (100%) survival of the skin graft was attained in all cases. No signs of complication were observed. With 30 years of experiences all combined, we have summarized fail-proof recommendations to a successful graft survival with an emphasis on the locations of its application.

  13. Surface modification of poly(styrene-b-(ethylene-co-butylene)-b-styrene) elastomer via photo-initiated graft polymerization of poly(ethylene glycol)

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaomeng [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Luan Shifang, E-mail: sfluan@ciac.jl.cn [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Yang Huawei; Shi Hengchong; Zhao Jie; Jin Jing [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Yin Jinghua, E-mail: yinjh@ciac.jl.cn [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Stagnaro, Paola [Istituto per Io Studio delle Macromolecole, Consiglio Nazionale delle Ricerche, Via de Marini 6, 16149 Genova (Italy)

    2012-01-15

    Poly(styrene-b-(ethylene-co-butylene)-b-styrene) (SEBS) copolymer biomedical elastomer was covalently grafted with poly(ethylene glycol) methyl ether methacrylate (PEGMA) via a photo-initiated graft polymerization technique. The surface graft polymerization of SEBS with PEGMA was verified by ATR-FTIR and XPS. Effect of graft polymerization parameters, i.e., monomer concentration, UV irradiation time and initiator concentration on the grafting density was investigated. Comparing with the virgin SEBS film, the PEGMA-modified SEBS film presented an enhanced wettability and a larger surface energy. Besides, the surface grafting of PEGMA imparted excellent anti-platelet adhesion and anti-protein adsorption to the SEBS surface.

  14. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  15. LATE RENAL GRAFT REJECTION: PATHOLOGY AND PROGNOSIS

    Directory of Open Access Journals (Sweden)

    E.S. Stolyarevich

    2014-01-01

    Full Text Available Rejection has always been one of the most important cause of late renal graft dysfunction. Aim of the study was to analyze the prevalence of different clinico-pathological variants of rejection that cause late graft dysfunction, and evaluate their impact on long-term outcome. Materials and methods. This is a retrospective study that analyzed 294 needle core biopsy specimens from 265 renal transplant recipients with late (48,8 ± 46,1 months after transplantation allograft dysfunction caused by late acute rejection (LAR, n = 193 or chronic rejection (CR, n = 78 or both (n = 23. C4d staining was performed by immunofl uorescence (IF on frozen sections using a standard protocol. Results. Peritubular capillary C4d deposition was identifi ed in 36% samples with acute rejection and in 62% cases of chronic rejection (including 67% cases of transplant glomerulopathy, and 50% – of isolated chronic vasculopathy. 5-year graft survival for LAR vs CR vs their combination was 47, 13 and 25%, respectively. The outcome of C4d– LAR was (p < 0,01 better than of C4d+ acute rejection: at 60 months graft survival for diffuse C4d+ vs C4d− was 33% vs 53%, respectively. In cases of chronic rejection C4d+ vs C4d– it was not statistically signifi cant (34% vs 36%. Conclusion. In long-term allograft biopsy C4d positivity is more haracteristic for chronic rejection than for acute rejection. Only diffuse C4d staining affects the outcome. C4d– positivity is associated with worse allograft survival in cases of late acute rejection, but not in cases of chronic rejection. 

  16. Radiation grafting of styrene and maleic anhydride onto PTFE membranes and sequent sulfonation for applications of vanadium redox battery

    International Nuclear Information System (INIS)

    Qiu Jingyi; Ni Jiangfeng; Zhai Maolin; Peng Jing; Zhou Henghui; Li Jiuqiang; Wei Genshuan

    2007-01-01

    Using γ-radiation technique, poly(tetrafluoroethylene) (PTFE) membrane was grafted with styrene (St) (PTFE-graft-PS) or binary monomers of St and maleic anhydride (MAn) (PTFE-graft-PS-co-PMAn), respectively. Then grafted membranes were further sulfonated with chlorosulfonic acid into ion-exchange membranes (denoted as PTFE-graft-PSSA and PTFE-graft-PSSA-co-PMAc, respectively) for application of vanadium redox battery (VRB). Micro-FTIR analysis indicated that PTFE was successfully grafted and sulfonated at the above two different conditions. However, a higher degree of grafting (DOG) was obtained in St/MAn binary system at the same dose due to a synergistic effect. Comparing with PTFE-graft-PSSA, PTFE-graft-PSSA-co-PMAc membrane showed higher water uptake and ion-exchange capacity (IEC) and lower area resistance (AR) at the same DOG. In addition, PTFE-graft-PSSA-co-PMAc with 6% DOG also showed a higher IEC and higher conductivity compared to Nafion membrane. Radiation grafting of PTFE in St/MAn binary system and sequent sulfonation is an appropriate method for preparing ion-exchange membrane of VRB

  17. Quantification of deposition of neutrophilic granulocytes on vascular grafts in dogs with 111In-labeled granulocytes

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Solis, E.; Mackey, S.T.; Socher, S.; Chowdhury, S.; Wu, F.P.; Kaye, M.P.

    1985-01-01

    A new radioisotopic technique has been developed for quantification of deposition of neutrophilic granulocytes on vascular grafts. Nine healthy mongrel dogs underwent bilateral femoral artery resection and reconstruction with grafts of the femoral vein and Gore-Tex. Pure granulocytes that had been separated from whole blood by centrifugal elutriation were labeled with 111 In-tropolone in plasma. The granulocyte harvesting efficiency was 25 +/- 12%, and the labeling efficiency was 87 +/- 7%. Three hours after injection of labeled granulocytes and 2 hours after reperfusion, the grafts were harvested and cut into several segments for study of areas of anastomoses and midsections. On the basis of the radioactivity in the blood and in anastomotic and graft sections, the area of graft sections, and the neutrophilic granulocyte and differential leukocyte counts, the number of neutrophilic granulocytes adherent to a unit area and the total number of neutrophilic granulocytes on graft sections were calculated. These quantifications of the deposition of neutrophilic granulocytes indicated that the midsections of Gore-Tex grafts retained more neutrophilic granulocytes than did the midsections of vein grafts. Although the anastomotic areas retained more neutrophilic granulocytes than did the midsections of vein grafts, the opposite finding prevailed for the Gore-Tex grafts. A major fraction of neutrophilic granulocytes on Gore-Tex grafts was incorporated into the thrombus. Semiquantitative information obtained by scintigraphy of the deposition of neutrophilic granulocytes on vascular grafts also confirmed this observation

  18. Cartilage grafting in nasal reconstruction.

    Science.gov (United States)

    Immerman, Sara; White, W Matthew; Constantinides, Minas

    2011-02-01

    Nasal reconstruction after resection for cutaneous malignancies poses a unique challenge to facial plastic surgeons. The nose, a unique 3-D structure, not only must remain functional but also be aesthetically pleasing to patients. A complete understanding of all the layers of the nose and knowledge of available cartilage grafting material is necessary. Autogenous material, namely septal, auricular, and costal cartilage, is the most favored material in a free cartilage graft or a composite cartilage graft. All types of material have advantages and disadvantages that should guide the most appropriate selection to maximize the functional and cosmetic outcomes for patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. [The anesthetic effects of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction].

    Science.gov (United States)

    Yang, Jieping; Liu, Wei; Gao, Qinghong

    2013-08-01

    To evaluate the anesthetic effects and safety of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction. A split-mouth study was designed. The bilateral impacted mandibular third molar of 32 participants were divided into Gow-Gates technique of inferior alveolar nerve block (Gow-Gates group) and conventional technique of inferior alveolar nerve block (conventional group) randomly with third molar extracted. The anesthetic effects and adverse events were recorded. All the participants completed the research. The anesthetic success rate was 96.9% in Gow-Gates group and 90.6% in conventional group with no statistical difference ( P= 0.317); but when comparing the anesthesia grade, Gow-Gates group had a 96.9% of grade A and B, and conventional group had a rate of 78.1% (P = 0.034). And the Gow-Gates group had a much lower withdrawn bleeding than conventional group (P = 0.025). Two groups had no hematoma. Gow-Gates technique had a reliable anesthesia effects and safety in impacted mandibular third molar extraction and could be chosen as a candidate for the conventional inferior alveolar nerve block.

  20. A simple sizing optimization technique for an impact limiter based on dynamic material properties

    International Nuclear Information System (INIS)

    Choi, Woo-Seok; Seo, Ki-Seog

    2010-01-01

    According to IAEA regulations, a transportation package for radioactive material should perform its intended function of containing the radioactive contents after a drop test, which is one of the hypothetical accident conditions. Impact limiters attached to a transport cask absorb most of the impact energy. So, it is important to determine the shape, size and material of impact limiters properly. The material data needed in this determination is a dynamic one. In this study, several materials considered as those of impact limiters were tested by drop weight equipment to acquire the dynamic material characteristics data. The impact absorbing volume of the impact limiter was derived mathematically for each drop condition. A size optimization of the impact limiter was conducted. The derived impact absorbing volumes were applied as constraints. These volumes should be less than the critical volumes generated based on the dynamic material characteristics. The derived procedure to decide the shape of the impact limiter can be useful at the preliminary design stage when the transportation package's outline is roughly determined and applied as an input value.

  1. A technique for position sensing and improved momentum evaluation of microparticle impacts in space.

    Science.gov (United States)

    Mcdonnell, J. A. M.; Abellanas, C.

    1972-01-01

    The design of a three element piezoelectric microparticle impact sensing diaphragm is described which is sensitive to the detection of momentum propagated by the bending wave. The design achieves a sensitivity of .03 microdyn/sec and optimizes the detection of the direct-path pulse from impact relative to secondary reflections and interference from discontinuities. Measurement of the relative arrival times and the maximum amplitudes of the outputs from the three piezoelectric sensors leads to the determination of the impact position and the normally resolved impact momentum exchange. Coincidence of the signals and a partial redundancy of data leads to a very high noise discrimination.

  2. Evaluation of Airborne Remote Sensing Techniques for Predicting the Distribution of Energetic Compounds on Impact Areas

    National Research Council Canada - National Science Library

    Graves, Mark R; Dove, Linda P; Jenkins, Thomas F; Bigl, Susan; Walsh, Marianne E; Hewitt, Alan D; Lambert, Dennis; Perron, Nancy; Ramsey, Charles; Gamey, Jeff; Beard, Les; Doll, William E; Magoun, Dale

    2007-01-01

    .... These sampling approaches do not accurately account for the distribution of such contaminants over the landscape due to the distributed nature of explosive compound sources throughout impact areas...

  3. Inheritance of graft compatibility in Douglas fir.

    Science.gov (United States)

    D.L. Copes

    1973-01-01

    Graft compatibility of genetically related and unrelated rootstock-scion combinations was compared. Scion clones were 75% compatible when grafted on half-related rootstocks but only 56% compatible when grafted on unrelated rootstocks. Most variance associated with graft incompatibility in Douglas-fir appears to be caused by multiple genes.

  4. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  5. Effect of centrifugation and washing on adipose graft viability: a new method to improve graft efficiency.

    Science.gov (United States)

    Hoareau, Laurence; Bencharif, Karima; Girard, Anne-Claire; Gence, Lydie; Delarue, Pierre; Hulard, Olivier; Festy, Franck; Roche, Regis

    2013-05-01

    Adipose tissue grafting is a promising method in the field of surgical filling. We studied the effect of centrifugation on fat grafts, and we propose an optimised protocol for the improvement of adipose tissue viability. Adipose tissue was subjected to different centrifugations, and the volumes of interstitial liquid and oil released were measured to choose the optimal condition. Tissue from this condition was then compared to tissue obtained from two traditional techniques: strong centrifugation (commonly 3 min at 3000 rpm/900 g), and decantation, by injecting into immunodeficient mice. The cytokine interleukin-6 (IL-6) and chemokine monocyte chemotactic protein-1 (MCP-1) were assayed 24 h post-injection, and after 1 month of grafting the state of the lipografts was evaluated through macroscopic and histological analysis, with oil gap area measurement. Strong centrifugation (900 g, 1800 g) is deleterious for adipose tissue because it leads to until threefold more adipocyte death compared to low centrifugation (100 g, 400 g). In addition, mice injected with strong centrifuged and non-centrifuged adipose tissue have higher rates of blood IL-6 and MCP-1, compared to those grafted with soft centrifuged fat. Moreover, extensive lipid vacuoles were detectable on histological sections of the non-centrifuged lipografts, whereas lipografts from soft centrifugation contain a higher amount of connective tissue containing collagen fibres. It is necessary to wash and centrifuge adipose tissue before reinjection in order to remove infiltration liquid and associated toxic molecules, which in the long term are deleterious for the graft. However, strong centrifugation is not recommended since it leads very quickly to greater adipocyte death. Thus, soft centrifugation (400 g/1 min), preceded by washings, seems to be the most appropriate protocol for the reinjection of adipose tissue. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published

  6. Grafting of Porous Polymers for Biological Applications

    Energy Technology Data Exchange (ETDEWEB)

    Smolko, E. E. [Comisión Nacional de Energía Atómica, Buenos Aires (Argentina); Grasselli, M. [Dpto. LaMaBio, Dpto. de Ciencia y Tecnología, Universidad Nacional de Quilmes, Bernal, Buenos Aires (Argentina)

    2009-07-01

    Research on application of radiation processing to polymers is mainly focused by the National Atomic Commission (CNEA). The Agricultural and Industrial Applications Laboratory Unit operates at the Ezeiza Atomic Center since the end of 1980s. Since 1997 a new research group headed by Dr. O. Cascone and Dr. M. Grasselli, devoted to downstream processing of proteins from the University of Buenos Aires, was involved in the implementation of grafting techniques in collaboration with Dr. E. Smolko from CNEA. In 1999 Dr. M. Grasselli moved to the Universidad Nacional de Quilmes where he continued working on application of gamma radiation to materials for biotechnological process. (author)

  7. Grafting of Porous Polymers for Biological Applications

    International Nuclear Information System (INIS)

    Smolko, E.E.; Grasselli, M.

    2009-01-01

    Research on application of radiation processing to polymers is mainly focused by the National Atomic Commission (CNEA). The Agricultural and Industrial Applications Laboratory Unit operates at the Ezeiza Atomic Center since the end of 1980s. Since 1997 a new research group headed by Dr. O. Cascone and Dr. M. Grasselli, devoted to downstream processing of proteins from the University of Buenos Aires, was involved in the implementation of grafting techniques in collaboration with Dr. E. Smolko from CNEA. In 1999 Dr. M. Grasselli moved to the Universidad Nacional de Quilmes where he continued working on application of gamma radiation to materials for biotechnological process. (author)

  8. Reshaping Human Antibodies: Grafting an Antilysozyme Activity

    Science.gov (United States)

    Verhoeyen, Martine; Milstein, Cesar; Winter, Greg

    1988-03-01

    The production of therapeutic human monoclonal antibodies by hybridoma technology has proved difficult, and this has prompted the ``humanizing'' of mouse monoclonal antibodies by recombinant DNA techniques. It was shown previously that the binding site for a small hapten could be grafted from the heavy-chain variable domain of a mouse antibody to that of a human myeloma protein by transplanting the hypervariable loops. It is now shown that a large binding site for a protein antigen (lysozyme) can also be transplanted from mouse to human heavy chain. The success of such constructions may be facilitated by an induced-fit mechanism.

  9. Muscle optimization techniques impact the magnitude of calculated hip joint contact forces

    NARCIS (Netherlands)

    Wesseling, M.; Derikx, L.C.; de Groote, F.; Bartels, W.; Meyer, C.; Verdonschot, Nicolaas Jacobus Joseph; Jonkers, I.

    2015-01-01

    In musculoskeletal modelling, several optimization techniques are used to calculate muscle forces, which strongly influence resultant hip contact forces (HCF). The goal of this study was to calculate muscle forces using four different optimization techniques, i.e., two different static optimization

  10. Decontamination of nuclear plant fluids with grafted celluloses

    International Nuclear Information System (INIS)

    Sandeaux, R.

    1991-01-01

    Ion exchange processes are specially well adapted techniques to solve some of nuclear plants problems, such as decontamination of the primary cooling circuit fluid and the cooling pool, because of the low concentration of the miscellaneous products to eliminate. Now the purification of these fluids is performed by using ion exchange resins. But recent researches show it is necessary to use more efficient techniques (1). The use of grafted celluloses should improve this process. The manufacturing of grafted celluloses was first performed with the collaboration of French Textile Institute and Morgane-Framatome (2). Cellulosic structure offers well known qualities for filtration: good micrometric retention, good mechanical behaviour, strong hydrophilic properties and high specific surface. Grafting was performed through a radiochemical process so as to bind polyelectrolytes on the backbone polymer. Compared to usual ion exchangers, these new materials offer different properties: - fast exchange kinetic - as uncrosslinked polymers, these grafted celluloses withstand better fouling with macroions or ionic complexes; - as they can be incinerated, radioactive wastes can be greatly reduced; - different commercial products of these grafted celluloses offer a wide range of possibilities for industrial uses [fr

  11. The Impact of Age on Clinical Outcomes of Coronary Artery Bypass Grafting: Long-Term Results of a Real-World Registry

    Directory of Open Access Journals (Sweden)

    Francesco Nicolini

    2017-01-01

    Full Text Available The aim of this retrospective multicenter registry study was to investigate age-dependent trends in mortality, long-term survival, and comorbidity over time in patients who underwent isolated CABG from 2003 to 2015. The percentage of patients < 60 years of age was 18.9%. Female sex, chronic pulmonary disease, extracardiac arteriopathy, and neurologic dysfunction disease were significantly less frequent in this younger population. The prevalence of BMI ≥ 30, previous myocardial infarction, preoperative severe depressed left ventricular ejection fraction, and history of previous PCI were significantly higher in this population. After PS matching, at 5 years, patients < 60 years of age reported significantly lower overall mortality (p<0.0001, cardiac-related mortality (p<0.0001, incidence of acute myocardial infarction (p=0.01, and stroke rates (p<0.0001. Patients < 60 years required repeated revascularization more frequently than older patients (p=0.05. Patients < 60 who underwent CABG had a lower risk of adverse outcomes than older patients. Patients < 60 have a different clinical pattern of presentation of CAD in comparison with more elderly patients. These issues require focused attention in order to design and improve preventive strategies aiming to reduce the impact of specific cardiovascular risk factors for younger patients, such as diet, lifestyle, and weight control.

  12. Design of a Sapling Branch Grafting Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available The automatic sapling grafting methods and grafting robot technologies are not comprehensively studied despite the fact that they are urgently required in practice. For this reason, a sapling grafting robot is developed to implement automatic grafting for saplings. The developed grafting robot includes clipping mechanism, moving mechanism, cutting mechanism, binding mechanism, and Arduino MCU based control system, which is capable of clipping, moving, positioning, cutting, grafting, and binding saplings. Experiments show that the stock cutting efficiency is 98.4%, the scion cutting efficiency is 98.9%, the grafting efficiency is 87.3%, and the binding efficiency is 68.9%.

  13. Vibration impact acoustic emission technique for identification and analysis of defects in carbon steel tubes: Part A Statistical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Zakiah Abd [Universiti Teknikal Malaysia Melaka (Malaysia); Jamaludin, Nordin; Junaidi, Syarif [Faculty of Engineering and Built, Universiti Kebangsaan Malaysia, Bangi (Malaysia); Yahya, Syed Yusainee Syed [Universiti Teknologi MARA, Shah Alam (Malaysia)

    2015-04-15

    Current steel tubes inspection techniques are invasive, and the interpretation and evaluation of inspection results are manually done by skilled personnel. This paper presents a statistical analysis of high frequency stress wave signals captured from a newly developed noninvasive, non-destructive tube inspection technique known as the vibration impact acoustic emission (VIAE) technique. Acoustic emission (AE) signals have been introduced into the ASTM A179 seamless steel tubes using an impact hammer, and the AE wave propagation was captured using an AE sensor. Specifically, a healthy steel tube as the reference tube and four steel tubes with through-hole artificial defect at different locations were used in this study. The AE features extracted from the captured signals are rise time, peak amplitude, duration and count. The VIAE technique also analysed the AE signals using statistical features such as root mean square (r.m.s.), energy, and crest factor. It was evident that duration, count, r.m.s., energy and crest factor could be used to automatically identify the presence of defect in carbon steel tubes using AE signals captured using the non-invasive VIAE technique.

  14. Environmental impact assessment of structural flood mitigation measures by a rapid impact assessment matrix (RIAM) technique: a case study in Metro Manila, Philippines.

    Science.gov (United States)

    Gilbuena, Romeo; Kawamura, Akira; Medina, Reynaldo; Amaguchi, Hideo; Nakagawa, Naoko; Bui, Duong Du

    2013-07-01

    In recent decades, the practice of environmental impact assessment (EIA) in the planning processes of infrastructure projects has created significant awareness on the benefits of environmentally sound and sustainable urban development around the world. In the highly urbanized megacities in the Philippines, like Metro Manila, high priority is given by the national government to structural flood mitigation measures (SFMM) due to the persistently high frequency of flood-related disasters, which are exacerbated by the on-going effects of climate change. EIA thus, should be carefully and effectively executed to maximize the potential benefits of the SFMM. The common practice of EIA in the Philippines is generally qualitative and lacks clear methodology in evaluating multi-criteria systems. Thus, this study proposes the use of the rapid impact assessment matrix (RIAM) technique to provide a method that would systematically and quantitatively evaluate the socio-economic and environmental impacts of planned SFMM in Metro Manila. The RIAM technique was slightly modified to fit the requirements of this study. The scale of impact was determined for each perceived impact, and based on the results, the planned SFMM for Metro Manila will likely bring significant benefits; however, significant negative impacts may also likely occur. The proposed modifications were found to be highly compatible with RIAM, and the results of the RIAM analysis provided a clear view of the impacts associated with the implementation of SFMM projects. This may prove to be valuable in the practice of EIA in the Philippines. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Platlet Rich Plasma (PRP) Improves Fat Grafting Outcomes.

    Science.gov (United States)

    Modarressi, Ali

    2013-01-01

    Autologous fat transfer offers many qualities of a ideal soft tissue filler. Main advantages of fat grafting ensue from the fact that the lipoaspirate tissue is an abundant source of regenerative pluripotential cells. However, the reported rates of fat cell survival vary greatly in the medical literature (10-90%). Different techniques of harvesting, processing, and reinjecting the fat cells are so claimed to be responsible for these differences, without any agreement concerning the best way to process. To address this important disadvantage, we propose the addition of autologous platelet rich plasma (PRP) which is known as a natural reservoir of growth factors stimulating tissue repair and regeneration. This approach is completely autologous and immediately employed without any type of preconditioning. Platelets rich plasma (PRP) preparation included bleeding of 8 ml of blood from patient's peripheral vein in Regen Lab© tubes containing sodium citrate anticoagulant. The whole blood was centrifugated at 1500 g during 3 min. As Regen-tubes contained a special gel separator, 99 % of red blood cells were discarded from the plasma at the bottom of the gel, and >90% of platelets were harvested in 4 ml of plasma on the top of the gel, called the platelet-rich plasma (PRP). The purified fat prepared by Coleman technique was mixed with different amount of PRP for in vitro, in vivo (mice) and clinical experiments: >50% of PRP for skin rejuvenation, superficial scars correction, infraorbital region, ..., and for 20% of PRP with 80% of purified fat for deep filler indication (nasolabial folds, lips, or soft tissue defect). In vitro studies demonstrated that PRP increased fat cells survival rate and stem cells differentiation. Animal models showed that fat graft survival rate was significantly increased by addition of PRP. Several clinical cases confirmed the improvement of wound healing and fat grafting survival in facial reconstruction and aesthetic cases by association of

  16. Characterization of impact materials around Barringer Meteor Crater by micro-PIXE and micro-SRXRF techniques

    Energy Technology Data Exchange (ETDEWEB)

    Uzonyi, I. E-mail: uzonyi@atomki.hu; Szoeor, Gy.; Rozsa, P.; Vekemans, B.; Vincze, L.; Adams, F.; Drakopoulos, M.; Somogyi, A.; Kiss, A.Z

    2004-06-01

    A combined micro-PIXE and micro-SRXRF method has been tested successfully for the characterization of impact materials collected at the well-known Barringer Meteor Crater. The micro-PIXE technique proved to be sensitive in the Z{<=}28 atomic number region while the micro-SRXRF above Fe especially for the siderophile elements. Quantitative analysis has become available for about 40 elements by these complementary methods providing new perspectives for the interpretation of the formation mechanism of impact metamorphosed objects.

  17. FAS grafted superhydrophobic ceramic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Yu Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Zhou Jianer [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Song Lixin; Hu Xingfang [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Larbot, Andre [Institut Europeen des Membranes, UMR 5635-CNRS, ENSCM, UMII, 1919 Route de Mende 34293, Montpellier Cedex 5 (France)

    2009-08-30

    The hydrophobic properties of {gamma}-Al{sub 2}O{sub 3} membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 deg. C) of the fluoroalkylsilane grafted on Al{sub 2}O{sub 3} powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and {gamma}-Al{sub 2}O{sub 3} membrane surface as well as the formed surface morphology.

  18. FAS grafted superhydrophobic ceramic membrane

    Science.gov (United States)

    Lu, Jun; Yu, Yun; Zhou, Jianer; Song, Lixin; Hu, Xingfang; Larbot, Andre

    2009-08-01

    The hydrophobic properties of γ-Al 2O 3 membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 °C) of the fluoroalkylsilane grafted on Al 2O 3 powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and γ-Al 2O 3 membrane surface as well as the formed surface morphology.

  19. Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques

    OpenAIRE

    MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an ...

  20. Engagement techniques and playing level impact the biomechanical demands on rugby forwards during machine-based scrummaging.

    Science.gov (United States)

    Preatoni, Ezio; Stokes, Keith A; England, Michael E; Trewartha, Grant

    2015-04-01

    This cross-sectional study investigated the factors that may influence the physical loading on rugby forwards performing a scrum by studying the biomechanics of machine-based scrummaging under different engagement techniques and playing levels. 34 forward packs from six playing levels performed repetitions of five different types of engagement techniques against an instrumented scrum machine under realistic training conditions. Applied forces and body movements were recorded in three orthogonal directions. The modification of the engagement technique altered the load acting on players. These changes were in a similar direction and of similar magnitude irrespective of the playing level. Reducing the dynamics of the initial engagement through a fold-in procedure decreased the peak compression force, the peak downward force and the engagement speed in excess of 30%. For example, peak compression (horizontal) forces in the professional teams changed from 16.5 (baseline technique) to 8.6 kN (fold-in procedure). The fold-in technique also reduced the occurrence of combined high forces and head-trunk misalignment during the absorption of the impact, which was used as a measure of potential hazard, by more than 30%. Reducing the initial impact did not decrease the ability of the teams to produce sustained compression forces. De-emphasising the initial impact against the scrum machine decreased the mechanical stresses acting on forward players and may benefit players' welfare by reducing the hazard factors that may induce chronic degeneration of the spine. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. ENVIRONMENTAL IMPACT ASSESSMENT OF LAND USE PLANING AROUND THE LEASED LIMESTONE MINE USING REMOTE SENSING TECHNIQUES

    Directory of Open Access Journals (Sweden)

    P. Ranade

    2007-01-01

    Full Text Available Mining activities and the waste products produced can have significant impact on the surrounding environment - ranging from localized surface and ground water contamination to the damaging effects of airborne pollutants on the regional ecosystem. The long term monitoring of environmental impacts requires a cost effective method to characterize land cover and land cover changes over time. As per the guidelines of Ministry of Environment and Forest, Govt. of India, it is mandatory to study and analyze the impacts of mining on its surroundings. The use of remote sensing technology to generate reliable land cover maps is a valuable asset to completing environmental assessments over mining affected areas. In this paper, a case study has been discussed to study the land use – land cover status around 10 Km radius of open cast limestone mine area and the subsequent impacts on environmental as well as social surroundings.

  2. [Fat grafting in facial burns sequelae].

    Science.gov (United States)

    Viard, R; Bouguila, J; Voulliaume, D; Comparin, J-P; Dionyssopoulos, A; Foyatier, J-L

    2012-06-01

    Fat graft is now part of the armamentarium in face plastic surgery. It is successfully used in burn scars. The aim of our study is the discussion of the value of this technique in optimizing cosmetic result of burns face sequelae. Fifteen adult patients (10 females and five males) with scars resulting from severe burns 2 to 9 years previously were selected. The patients were treated by injection of adipose tissue harvested from abdominal subcutaneous fat and processed according to Coleman's technique. Two to three injections were administered at the dermohypodermal junction. Ages, sexes, aetiology of burn, facial burn sequelae, recipient sites, quantity of fat injected, aesthetic results are discussed. Patient age ranged from 21 to 55 years (average: 38). The mean follow-up of the study was 66 months (23-118). Patients received 7.5 (5-11) facial restorative surgeries before fat graft. Patients underwent two sessions of fat transfer, 33cc average per session. We did not report any complications. The clinical appearance, discussed by three surgeons and subjective patient feelings, after a 6-month follow-up period, suggests considerable improvement in the mimic features, skin texture, and thickness. The result is good in 86% of cases and acceptable in the other cases. Burns sequelae offer local conditions which justify special cannula can cross fibrosis and explaining the value of multiplying the sessions. Indications for lipostructure include four distinct nosological situations, sometimes combined. Lipostructure can restore a missing relief, filling a localized depression, reshape a lack of face volume or smooth a scarring skin. Fat graft seems to complete and improve the results of the standard surgical approach in burned face. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  3. Controlled grafting of cellulose esters using SET-LRP process

    Czech Academy of Sciences Publication Activity Database

    Vlček, Petr; Raus, Vladimír; Janata, Miroslav; Kříž, Jaroslav; Sikora, Antonín

    2011-01-01

    Roč. 49, č. 1 (2011), s. 164-173 ISSN 0887-624X R&D Projects: GA ČR GA106/09/1348 Institutional research plan: CEZ:AV0Z40500505 Keywords : cellulose esters * copolymerization * graft copolymers Subject RIV: JI - Composite Materials Impact factor: 3.919, year: 2011

  4. Grafting of alumina on SBA-15: Effect of surface roughness

    Czech Academy of Sciences Publication Activity Database

    Zukal, Arnošt; Šiklová, Helena; Čejka, Jiří

    2008-01-01

    Roč. 24, č. 17 (2008), s. 9837-9842 ISSN 0743-7463 R&D Projects: GA AV ČR KAN100400701 Institutional research plan: CEZ:AV0Z40400503 Keywords : alumina-grafted materials * SBA-15 * Nitrogen adsorption Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.097, year: 2008

  5. Nanocomposite of polystyrene foil grafted with metallaboranes for antimicrobial activity

    Czech Academy of Sciences Publication Activity Database

    Benkocká, M.; Kolářová, K.; Matoušek, J.; Semerádtová, A.; Šícha, Václav; Kolská, Z.

    2018-01-01

    Roč. 441, MAY (2018), s. 120-129 ISSN 0169-4332 R&D Projects: GA MŠk(CZ) LM2015073 Institutional support: RVO:61388980 Keywords : Antimicrobial activity * Chemical grafting * Metallaboranes * Piranha solution * Polystyrene * Surface properties Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 3.387, year: 2016

  6. Vibration impact acoustic emission technique for identification and analysis of defects in carbon steel tubes: Part B Cluster analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Zakiah Abd [Universiti Teknikal Malaysia Melaka (Malaysia); Jamaludin, Nordin; Junaidi, Syarif [Faculty of Engineering and Built, Universiti Kebangsaan Malaysia, Bangi (Malaysia); Yahya, Syed Yusainee Syed [Universiti Teknologi MARA, Shah Alam (Malaysia)

    2015-04-15

    Current steel tubes inspection techniques are invasive, and the interpretation and evaluation of inspection results are manually done by skilled personnel. Part A of this work details the methodology involved in the newly developed non-invasive, non-destructive tube inspection technique based on the integration of vibration impact (VI) and acoustic emission (AE) systems known as the vibration impact acoustic emission (VIAE) technique. AE signals have been introduced into a series of ASTM A179 seamless steel tubes using the impact hammer. Specifically, a good steel tube as the reference tube and four steel tubes with through-hole artificial defect at different locations were used in this study. The AEs propagation was captured using a high frequency sensor of AE systems. The present study explores the cluster analysis approach based on autoregressive (AR) coefficients to automatically interpret the AE signals. The results from the cluster analysis were graphically illustrated using a dendrogram that demonstrated the arrangement of the natural clusters of AE signals. The AR algorithm appears to be the more effective method in classifying the AE signals into natural groups. This approach has successfully classified AE signals for quick and confident interpretation of defects in carbon steel tubes.

  7. Vibration impact acoustic emission technique for identification and analysis of defects in carbon steel tubes: Part B Cluster analysis

    International Nuclear Information System (INIS)

    Halim, Zakiah Abd; Jamaludin, Nordin; Junaidi, Syarif; Yahya, Syed Yusainee Syed

    2015-01-01

    Current steel tubes inspection techniques are invasive, and the interpretation and evaluation of inspection results are manually done by skilled personnel. Part A of this work details the methodology involved in the newly developed non-invasive, non-destructive tube inspection technique based on the integration of vibration impact (VI) and acoustic emission (AE) systems known as the vibration impact acoustic emission (VIAE) technique. AE signals have been introduced into a series of ASTM A179 seamless steel tubes using the impact hammer. Specifically, a good steel tube as the reference tube and four steel tubes with through-hole artificial defect at different locations were used in this study. The AEs propagation was captured using a high frequency sensor of AE systems. The present study explores the cluster analysis approach based on autoregressive (AR) coefficients to automatically interpret the AE signals. The results from the cluster analysis were graphically illustrated using a dendrogram that demonstrated the arrangement of the natural clusters of AE signals. The AR algorithm appears to be the more effective method in classifying the AE signals into natural groups. This approach has successfully classified AE signals for quick and confident interpretation of defects in carbon steel tubes.

  8. [Clinical study of modified Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction].

    Science.gov (United States)

    Hu, Yi-ping; Jin, Gui-fang

    2015-06-01

    To introduce a minimally invasive and more effective technique of inferior alveolar nerve block. Two hundred and six patients who needed extraction of the impacted mandibular third molar were divided randomly into 2 groups: the experimental group (105 cases) with modified Gow-Gates technique (modified Gow-Gates group) and the control group (101 cases) with Halstead technique (Halstead group). The anesthetic success rates, effects and complications were recorded and analyzed with SPSS17.0 software package. The anesthetic success rate was 97.15% in modified Gow-Gates group and 89.10% in Halstead group with significant difference between the 2 groups (P=0.0380.05). Modified Gow-Gates group had much fewer of complications than Halstead group (P=0.014inferior alveolar nerve block anesthesia. Supported by Science and Technology Planning Project of Yueqing City (2014y027).

  9. SENSE-MAKING TECHNIQUES IN EDUCATIONAL PROCESS AND THEIR IMPACT ON THE PERSONAL CHARACTERISTICS OF STUDENTS

    Directory of Open Access Journals (Sweden)

    Irina V. Abakumova

    2017-12-01

    Full Text Available This study looks into psychotechnics used in education and contributing to initiating logic among students, their personal growth and characterizes psychological features of “sense-deducting”. Here you will find a review of the sense-making techniques considering as one of the categories of psychotechnics. The described techniques are based on the human psychology, they improve the quality of instruction, create a favorable and unique system of values, take into account the individual characteristics of all types of education, and influence the sense-making process development among children. Sense-making techniques are stated in the author’s classification and extended by practical methods. The study of psychological features of influence of sense-making techniques on the personality of a student lets us see new patterns in personal, subjective and “meta-subjective” results of acquiring of the school program via transformation and development of value/logic consciousness of a child. The work emphasizes that the use of sense-making techniques is effective in the educational and after-school activities of the educational organization. The achieved results make it possible to understand, to substantiate the naturalness and relevance of the sense-technical approach according to personal and academic indicators of students. In the process of competent and correct use of the semantic techniques, we see the possibility of conveying the best, productive and quality pedagogical experience, as well as the perspective of innovative developments in the psychological and pedagogical sciences. For children and adolescents, information, thanks to sense-techniques, starts to be personal in nature, knowledge is objectified, learning activity becomes an individual need.

  10. Surface modification of cation exchange membranes by graft polymerization of PAA-co-PANI/MWCNTs nanoparticles

    International Nuclear Information System (INIS)

    Nemati, Mahsa; Hosseini, Sayed Mohsen; Bagheripour, Ehsan; Madaeni, Sayed Siavash

    2016-01-01

    Surface modification of polyvinylchloride based heterogeneous cation exchange membrane was performed by graft polymerization of PAA and PAA-co-PANI/MWCNTs nanoparticles. The ion exchange membranes were prepared by solution casting technique. Spectra analysis confirmed graft polymerization clearly. SEM images illustrated that graft polymerization covers the membranes by simple gel network entanglement. The membrane water content was decreased by graft polymerization of PAA-co-PANI/MWCNTs nanoparticles on membrane surface. Membrane transport number and selectivity declined initially by PAA graft polymerization and then began to increase by utilizing of composite nanoparticles in modifier solution. The sodium and barium flux was improved sharply by PAA and PAAco- 0.01%wt PANI/MWCNTs graft polymerization on membrane surface and then decreased again by more increase of PANI/MWCNTs nanoparticles content ratio in modifier solution. The electrodialysis experiment results in laboratory scale showed higher dialytic rate in heavy metals removal for grafted-PAA and grafted-PAA-co-PANI/MWCNTs modified membrane compared to pristine one. Membrane areal electrical resistance was also decreased by introducing graft polymerization of PAA and PAA-co-PANI/MWCNTs NPs on membrane surface.

  11. Total and regional blood flows in vascularized skeletal muscle grafts in rabbits

    International Nuclear Information System (INIS)

    Burton, H.W.; Stevenson, T.R.; Dysko, R.C.; Gallagher, K.P.; Faulkner, J.A.

    1988-01-01

    The transplantation of whole skeletal muscles is a common clinical procedure. Although atypical blood flows have been reported in small free muscle grafts, the blood flow of large neurovascular-intact (NVI) and neurovascular-anastomosed (NVA) grafts have not been measured. Because the maximum specific force (N/cm 2 ) of NVI and NVA grafts is 65% that of control muscles, we hypothesized that total and regional blood flows of NVI and NVA grafts at rest and during twitch contractions are significantly lower than lower flows of control muscles. In rabbits, blood flows of control rectus femoris (RFM) muscles and NVI and NVA grafts of RFM muscles were measured by the radioactive-microsphere technique. Total blood flows in grafts were not different from the control RFM muscle values, except for a higher resting flow in NVA grafts and a lower flow at 3 Hz in NVI grafts. Minor variations in regional flows were observed. We conclude that the operative procedures of grating and repair of blood vessels affect the vascular bed of muscles minimally, and the deficits observed in grafts do not arise from inadequate perfusion

  12. Production of functional sperm by subcutaneous auto-grafting of immature testes in rainbow trout.

    Science.gov (United States)

    Hayashi, Makoto; Sakuma, Daika; Yoshizaki, Goro

    2018-02-01

    Sexually mature individuals are indispensable for breeding programs. Salmonids require a long period before reaching sexual maturity, so we aimed to shorten the period required to obtain functional sperm by grafting immature testicular fragments into mature recipients, which we predicted would allow the grafted testicular fragments to skip the long pre-pubertal period. First, we demonstrated successful subcutaneous auto-grafting of testicular fragments in rainbow trout. Unilateral testectomy was performed, and the isolated immature testicular fragment was auto-grafted into the subcutaneous space along the back of recipient fish. The grafted testicular fragments developed synchronously with the recipients' testis remaining in its body cavity, and both eventually produced functional sperm. Next, immature testicular fragments were auto-grafted into the subcutaneous space of sexually mature males. We achieved this, without immune rejection, by isolating and cryopreserving testes from immature fish, and rearing these unilaterally testectomized fish until sexual maturity. The cryopreserved testes were then auto-grafted into the original, now spermiating fish. The grated immature testicular fragments differentiated and produced functional sperm within 5 months after grafting. By combining this grafting method with a technique to avoid immune rejection, we expect to develop a practical method for producing sperm in a shorter period in salmonids. © 2017 Wiley Periodicals, Inc.

  13. Rapamycin treatment is associated with an increased apoptosis rate in experimental vein grafts.

    Science.gov (United States)

    Schachner, Thomas; Oberhuber, Alexander; Zou, Yping; Tzankov, Alexandar; Ott, Harald; Laufer, Günther; Bonatti, Johannes

    2005-02-01

    Rapamycin is an immunosuppressive agent with marked antiproliferative properties and is effective in reducing in stent restenosis and vein graft neointimal hyperplasia. Apoptosis is one mechanism counterbalancing cellular proliferation. We therefore investigated the role of apoptosis in rapamycin treated vein grafts in a mouse model. C57BL6J mice underwent interposition of the inferior vena cava from isogenic donor mice into the common carotid artery using a cuff technique. In the treatment group 200 microg of rapamycin were applied locally in pluronic gel. The control group did not receive local treatment. Vein grafts were harvested at 4 weeks postoperatively and underwent morphometric analysis as well as immunohistochemical analysis for apoptosis (TUNEL). In grafted veins without treatment (controls) neointimal thickness was 50 (12-58) microm at 4 weeks postoperatively. In 200 microg rapamycin treated grafts the neointimal thickness was 17 (5-55) microm. Rapamycin treated vein grafts showed a significantly increased rate of apoptosis in the adventitia as compared with controls (P=0.032). In the neointima the apoptosis rate was lower in both groups with no significant difference between rapamycin treated grafts and controls. We conclude that treatment of experimental vein grafts with rapamycin is associated with an increased apoptosis rate in the vascular wall and a trend towards reduction of neointimal hyperplasia. These results suggest that apoptosis may be a beneficial antiproliferative component for the treatment of vein graft disease.

  14. Post irradiation effects on the graft of poly(tetrafluoroethylene-co-perfluoropropyl vinyl ether) (PFA) films

    International Nuclear Information System (INIS)

    Geraldes, Adriana N.; Zen, Heloisa A.; Ribeiro, Geise; Ferreira, Henrique P.; Souza, Camila P.; Parra, Duclerc F.; Lugao, Ademar B.

    2009-01-01

    Radiation induced grafting of monomers into fluorinated polymers was designed as an alternative route to polymer modification. In this work, grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropyl vinyl ether) (PFA) was studied. Radiation-induced grafting of styrene onto PFA films was investigated after simultaneous irradiation (in post-irradiation condition) using a 60 Co source. The films of PFA were irradiated at 20, 40, 80 and 100 kGy doses at room temperature and chemical changes were monitored after contact with styrene for grafting. The post-irradiation time was established between 7 and 28 days when films of PFA were maintained in styrene/toluene 1:1 v/v solution at room temperature. After these periods the grafting degrees were evaluated in the samples. The highest degree of grafting was achieved after 14 days. Chemical modifications were evaluated by infrared spectroscopic analysis (FTIR), thermogravimetry (TG), differential scanning calorimetry (DSC) and also by scanning electron microscopy (SEM). The degree of grafting (DOG) was determined gravimetrically. The results showed that irradiated PFA films at 100 kGy exhibited higher grafting degree. Surface analysis by SEM technique of irradiated, grafted and original films have presented an homogeneous surface. (author)

  15. Piezosurgery vs High Speed Rotary Handpiece: a comparison between the two techniques in the impacted third molar surgery.

    Science.gov (United States)

    Bartuli, F N; Luciani, F; Caddeo, F; DE Chiara, L; DI Dio, M; Piva, P; Ottria, L; Arcuri, C

    2013-01-01

    The aim of the Study was to compare the impacted third molar surgical technique by means of the high speed rotary handpiece with the piezoelectric one. 192 patients have been selected among those who had to undergo a third molar surgical extraction. These patients' surgeries have been performed by means of one of the techniques, randomly chosen. Each patient has undergone the same analgesic therapy (paracetamol 1000 mg tablets). Each surgery has been performed by the same surgeon. The patients were asked to fill in a questionnaire concerning the postoperative pain ("happy face pain" rating scale). The average duration of the surgeries performed by means of the high speed rotary handpiece was 32 minutes, while the duration of the ones performed by means of the piezoelectric handpiece was much longer (54 minutes). The postoperative pain values were almost equal. In conclusion, the osteotomy performed by means of the traditional technique still represents the gold standard in the impacted third molar surgery. The piezoelectric technique may be an effective choice, especially for the less skilled surgeons, in order to guarantee the protection of the delicate locoregional anatomical structures.

  16. Iatrogenic giant cell tumor at bone graft harvesting site

    Directory of Open Access Journals (Sweden)

    Zile S Kundu

    2013-01-01

    Full Text Available 30 year old female patient with giant cell tumor of the distal tibia initially treated at a peripheral nononcological center by curettage and autologous bone grafting from the ipsilateral iliac crest reported to us with local recurrence and an implantation giant cell tumor at the graft harvesting site which required extensive surgeries at both sites. The risk of iatrogenic direct implantation of tumor, often attributable to inadequate surgical planning or poor surgical techniques, and the steps to prevent such complication is reported here.

  17. Effect of calvarial burring on resorption of onlay cranial bone graft.

    Science.gov (United States)

    Hassanein, Aladdin H; Clune, James E; Mulliken, John B; Arany, Praveen R; Rogers, Gary F; Kulungowski, Ann M; Greene, Arin K

    2012-09-01

    Variable resorption occurs whenever calvarial bone graft is used for onlay cranioplasty. The recipient ectocortex may be burred to expose vessels and osteocytes to maximize healing. The purpose of this study was to determine whether abrading the recipient site improves the volume of onlay graft. The parietal bones of 17 rabbits were sectioned into split-thickness and full-thickness grafts. The right frontal cortex was abraded with a bur to punctate bleeding. Pairs of split-thickness (n = 48) or full-thickness (n = 20) grafts were onlayed to the burred right frontal bone and to the nonburred left frontal bone. Micro-computed tomography was used to determine graft volume immediately postoperatively and 16 weeks later. Histology, including tartrate-resistant acid phosphatase staining, was performed to quantify vascular channels and osteoclasts per high-power field 10 days postoperatively. Split-thickness graft volume decreased 58.0% when placed on the burred calvarial site, compared with grafts on the nonburred cortex (28.4%) (P = 0.01). Full-thickness grafts showed a similar trend: greater resorption (39.1%) when onlayed onto abraded calvaria compared with nonburred ectocortex (26.0%) (P = 0.11). Split-thickness graft orientation (cortical vs cancellous side in contact with the recipient site) did not affect resorption (P = 0.67). Onlay grafts placed on the burred recipient site had more vascular channels (11.8) and osteoclasts (5.7), compared with grafts over nonabraded cortex (3.4 and 4.2, respectively) (P cranial bone grafting promotes resorption, possibly by increasing vascularization and osteoclastic activity. This technique cannot be recommended.

  18. The Application of Load-cell Technique in the Study of Armour Unit Responses to Impact Loads Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1995-01-01

    The slender, complex types of armour units, such as Tetrapods and Dolosse are widely used for rubble mound breakwaters. Many of the recent failures of such structures were caused by unforeseen early breakage of the units, thus revealing an in balance between the strength (structural integrity......) of the units and the hydraulic stability (resistance to displacements) of the armour layers. Breakage is caused by stresses from static, pulsating and impact loads. Impact load generated stresses are difficult to investigate due to non-linear scaling laws. The paper describes a method by which impact loads on....... slender armour units can be studied. by load-cell technique. Moreover, the paper presents DoJos design diagrams for the prediction of both breakage and hydraulic stability...

  19. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  20. Aging and its impact onthe quality of grafts: an experimental study in rats livers O impacto do envelhecimento na qualidade do enxerto: estudo experimental em fígados de ratos

    Directory of Open Access Journals (Sweden)

    Stela Maria Mota

    2010-09-01

    Full Text Available CONTEXT: There are consistent clues of worse results with grafts from older donors, especially in hepatitis C. University of Wisconsin (UW solution is adopted for liver preservation, but other solutions are being studied, as fructose-1,6-bisphosphate (FBP. OBJECTIVE: To determinate the impact of aging of the donor on the cold ischemia injury in rat livers and compare UW and FBP. METHODS: Twenty male Wistar rats were studied - 10, aging 20 weeks: 5 to preservation with UW (C-UW and 5, FBP (C-FBP; and other 10, aging 50 weeks: 5 to UW (E-UW and 5 to FBP (E-FBP. Rats were anesthesized, submitted to hepatectomy, and graft was kept under 2-4ºC for 8 hours. Liquid samples were taken at 2, 4, 6, and 8 hours, to determine AST and LDH. At the end, in the liver tissue thiobarbituric acid reactive substances and catalase were determined. RESULTS: Average liver weight was similar between controls and the others (12.5 g ± 1.8 and 13.4 g ± 2.0. AST and LDH levels were higher in C-UW group (PCONTEXTO: Dados da literatura atual sugerem piores resultados quando os transplantes hepáticos são realizados com enxertos provenientes de doadores idosos. O uso da solução Universidade de Wisconsin (UW é universal; entretanto alternativas como a fructose-1,6-bisfosfato (FBP vêm sendo estudadas. OBJETIVOS: Determinar o impacto do envelhecimento do doador no dano de isquemia a frio em fígados de ratos, comparando as soluções de FBP e UW. MÉTODOS: Vinte ratos Wistar foram estudados - 10 com 20 semanas: 5 preservados com UW (C-UW e 5 com FBP (C-FBP; e outros 10, com 50 semanas: 5 com UW (E-UW e 5 com FBP (E-FBP. A preservação durou 8 horas. Foram dosadas AST e LDH nas alíquotas do líquido de preservação a cada 2 horas. RESULTADOS: Os níveis de AST e LDH foram superiores no grupo (C-UW (P<0.05. Quando comparadas UW x FBP no grupo de idosos houve diferença quanto à LDH, mas não com a AST. CONCLUSÃO: A preservação dos fígados de ratos idosos foi

  1. Fruit quality of seedless watermelon grafted onto squash rootstocks under different production systems.

    Science.gov (United States)

    Liu, Qianru; Zhao, Xin; Brecht, Jeffrey K; Sims, Charles A; Sanchez, Tatiana; Dufault, Nicholas S

    2017-11-01

    The market demand for seedless watermelon has been continuously increasing because of consumer preference. Grafting is a useful tool to manage soilborne diseases in watermelon production, but the use of squash rootstocks may negatively affect watermelon fruit quality. Currently, most research has focused on seeded cultivars, while grafting effects on seedless watermelons remain largely unknown. This multi-season study was conducted to assess the effects of squash rootstocks, including both Cucurbita maxima × C. moschata and C. moschata cultivars, with intact or excised and regenerated roots, on fruit quality of seedless watermelon 'Melody' using both instrumental and sensory measurements under different production scenarios. The grafted watermelon plants were also challenged by field inoculation with Fusarium oxysporum f.sp. niveum. A combination of instrumental measurements and consumer sensory analyses suggested that fruit quality of the seedless watermelon 'Melody' was not impacted by the use of the squash rootstocks used in this study, which included soluble solids content, titratable acidity, pH and most fruit sensory properties. Watermelon flesh firmness was increased by grafting but the grafting effect on lycopene content was inconclusive. Root excision and regeneration did not influence the grafting effect, whereas the grafting effect on flesh firmness varied among the rootstocks under Fusarium inoculation. Overall, grafting with squash rootstocks did not reduce fruit quality attributes of 'Melody' but improved texture. Our results support incorporating grafting into integrated management programs for seedless watermelon production. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. Radioinduced grafting of acrylic acid on expanded polystyrene matrices

    International Nuclear Information System (INIS)

    Postolache, C.; Simion, Corina; Dragomir, A.; Ponta, C.; Chirvasoiu, G.; Postolache, Carmen

    1998-01-01

    The unfixed surface radioactive contamination for low energy β radionuclides ( 3 H and 14 C) is determined by wiping the checked surfaces with sponge of absorbent materials. The activity built up by this sponge is measured by a liquid scintillator spectrometer. In this work, a method of obtaining sponges of expanded polystyrene with hydrophobic surface by radioinduced grafting of the acrylic acid is presented. These sponges have diameters of 28 mm, thicknesses of 1.5 - 2 mm and density of 22 mg/cm 3 . The samples were immersed in a grafting solution with the following composition: acrylic acid 30%, Cu SO 4 1%; water 69% which were deeply impregnated in repeated operations under vacuum and pressure conditions, respectively. Finally, the samples were exposed to γ radiation emitted by a 60 Co source (IETI 10 000 - IFIN-HH). The dose rates were 0.3, 0.5 and 1 Mrad/h. The range of the absorbed doses was 1 - 25 Mrad. The yields of radiochemical grafting have been determined by gravimetric, spectrophotometric and radiometric methods. The grafting agent used was 3 H labelled acrylic acid. The solvation capacity and the quenching characteristics of the grafted sponges in liquid scintillators, as well as the sampling yields have been analyzed as function of irradiation procedure and the percentage of grafted acrylic fragments. The superficial grafting of the acrylic acid has been carried out by the mentioned technique, leading to the increase of the wiping efficiency of the unfixed surface contaminating activity, without changes of polymer solubility in liquid scintillators and without the perturbation of the radioactivity detection process. (authors)

  3. Surface functionalization of cellulose by grafting oligoether chains

    International Nuclear Information System (INIS)

    Ly, El hadji Babacar; Bras, Julien; Sadocco, Patrizia; Belgacem, Mohamed Naceur; Dufresne, Alain; Thielemans, Wim

    2010-01-01

    Two cellulosic substrates (Whatman paper and wood fibres) were chemically modified using different oligoether chains; poly(ethylene) (POE), poly(propylene) (PPG) and poly(tetrahydrofuran) (PTHF) glycols with different lengths were first converted into mono-NCO-terminating macromolecules to allow direct grafting to the cellulose substrates. This step was achieved by reacting the chosen oligoether with 2,4-toluene diisocyanate. The prepared macromolecular grafts were then coupled with the cellulose surface and the resulting treated substrates were fully characterized by contact angle measurements, elemental analysis, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Thus, all the techniques implemented showed clear evidence of successful grafting, namely: (i) when using PPG grafts, the polar contribution to the surface energy decreased from approximately 25 to virtually 0 mJ m -2 and the wettability by water decreased, as the water contact angle shifted from around 40 to above 90 o ; (ii) nitrogen atoms were detected by elemental analysis and XPS; (iii) the aliphatic carbon contents increased from 11 to about 39-50%, depending on the oligoether used; and (iv) small spheres having about 100 nm diameter were detected by SEM. Moreover, the grafted fibres were submitted to biodegradation tests which showed that they conserved their biodegradable character, although with a slower biodegradation rate. The novelty of the present paper is the direct grafting of the polymeric matrix onto the fibre surface thanks to a new modification strategy involving the use of a diisocyanate as a mediator between the matrix and the reinforcing elements. The covalently linked polymeric chains constituting the matrix could melt under heating, thus, yielding the interdiffusion of the macromolecular grafts and forming the composite.

  4. Life cycle environmental impacts of advanced wastewater treatment techniques for removal of pharmaceuticals and personal care products (PPCPs).

    Science.gov (United States)

    Zepon Tarpani, Raphael Ricardo; Azapagic, Adisa

    2018-06-01

    Pharmaceutical and personal care products (PPCPs) are of increasing interest because of their ecotoxicological properties and environmental impacts. Wastewater treatment plants (WWTPs) are the main pathway for their release into freshwaters due to the inefficiency of conventional WWTPs in removing many of these contaminants from effluents. Therefore, different advanced effluent treatment techniques have been proposed for their treatment. However, it is not known at present how effective these treatment methods are and whether on a life cycle basis they cause other environmental impacts which may outweigh the benefits of the treatment. In an effort to provide an insight into this question, this paper considers life cycle environmental impacts of the following advanced treatment techniques aimed at reducing freshwater ecotoxicity potential of PPCPs: granular activated carbon (GAC), nanofiltration (NF), solar photo-Fenton (SPF) and ozonation. The results suggest that on average NF has the lowest impacts for 13 out of 18 categories considered. GAC is the best alternative for five impacts, including metals and water depletion, but it has the highest marine eutrophication. SPF and ozonation are the least sustainable for eight impacts, including ecotoxicity and climate change. GAC and NF are also more efficient in treating heavy metals while avoiding generation of harmful by-products during the treatment, thus being more suitable for potable reuse of wastewater. However, releasing the effluent without advanced treatment to agricultural land achieves a much higher reduction of freshwater ecotoxicity than treating it by any of the advanced treatments and releasing to the environment. Therefore, the use of advanced effluent treatment for agricultural purposes is not recommended. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. The impact of machine learning techniques in the study of bipolar disorder: A systematic review.

    Science.gov (United States)

    Librenza-Garcia, Diego; Kotzian, Bruno Jaskulski; Yang, Jessica; Mwangi, Benson; Cao, Bo; Pereira Lima, Luiza Nunes; Bermudez, Mariane Bagatin; Boeira, Manuela Vianna; Kapczinski, Flávio; Passos, Ives Cavalcante

    2017-09-01

    Machine learning techniques provide new methods to predict diagnosis and clinical outcomes at an individual level. We aim to review the existing literature on the use of machine learning techniques in the assessment of subjects with bipolar disorder. We systematically searched PubMed, Embase and Web of Science for articles published in any language up to January 2017. We found 757 abstracts and included 51 studies in our review. Most of the included studies used multiple levels of biological data to distinguish the diagnosis of bipolar disorder from other psychiatric disorders or healthy controls. We also found studies that assessed the prediction of clinical outcomes and studies using unsupervised machine learning to build more consistent clinical phenotypes of bipolar disorder. We concluded that given the clinical heterogeneity of samples of patients with BD, machine learning techniques may provide clinicians and researchers with important insights in fields such as diagnosis, personalized treatment and prognosis orientation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Impact of the Intracoronary Rendezvous technique on coronary angioplasty for chronic total occlusion.

    Science.gov (United States)

    Nihei, Taro; Yamamoto, Yoshito; Kudo, Shun; Hanawa, Kenichiro; Hasebe, Yuhi; Takagi, Yusuke; Minatoya, Yutaka; Sugi, Masafumi; Shimokawa, Hiroaki

    2017-10-01

    The Rendezvous technique, which requires bidirectional wiring, is one of the useful methods for improving the success rate of recanalization for chronic total occlusion (CTO) in the field of peripheral intervention. Recently, advanced new devices for percutaneous coronary intervention have enabled us to perform the Rendezvous technique for peripheral as well as for coronary CTO lesions. We used the Intracoronary Rendezvous technique to perform angioplasty for coronary CTO. "Intracoronary Rendezvous" means that Rendezvous was achieved within the CTO lesion. From March 2009 to November 2015, 189 patients underwent CTO angioplasty at our institute, and we treated 10 patients with the Intracoronary Rendezvous technique. This technique involves crossing the Gaia series guidewire to the contralateral Corsair microcatheter located inside the plaque of CTO lesions. The majority of the CTO sites examined were in the proximal RCA (60 %). Lesion length of the occlusion was relatively long (64.4 ± 12.2 mm). Using the biplane imaging system, we were able to control the Gaia guidewires in a specific direction. Furthermore, if the antegrade and retrograde wires can be advanced into contiguous space inside the CTO lesion, we intentionally entered either wire into the contralateral Corsair microcatheter, followed by successful CTO crossing. CTO recanalization was completed for all patients without controlled antegrade retrograde subintimal tracking (CART) or reverse CART. No major complications occurred during hospitalization. These results indicate that the Rendezvous technique, assisted by new devices and a biplane imaging system, represents one of the primary options to achieve successful coronary CTO recanalization.

  7. Surface treatment of poly(ethylene terephthalate) by gamma-ray induced graft copolymerization of methyl acrylate and its toughening effect on poly(ethylene terephthalate)/elastomer blend

    International Nuclear Information System (INIS)

    Ma, Liang; Wang, Mozhen; Ge, Xuewu

    2013-01-01

    To improve the compatibility between ethylene-methyl acrylate-glycidyl methacrylate random terpolymer (E-MA-GMA) elastomer and poly(ethylene terephthalate) (PET), thereby enhance the toughening effect of E-MA-GMA on PET, γ-radiation-induced graft copolymerization technique was used to graft methyl acrylate (MA) monomer onto PET. The produced PET-g-PMA copolymer can be used as a self-compatibilizer in PET/E-MA-GMA blend since the copolymer contains the same segments, respectively, with PET and E-MA-GMA. The impact strength of PET/E-MA-GMA blend increased nearly by 30% in the presence of less than 0.1 wt% PET-g-PMA compared with that of the neat PET/elastomer blend, without loss of the tensile strength of the blends. This work proposed a potential application of radiation-induced grafting copolymerization technique on the in-situ compatibilization of PET/elastomer blends so as to improve the integral mechanical properties of PET based engineering plastic. - Highlights: • PMA was grafted onto PET resins by γ-ray radiation-induced copolymerization. • The obtained PET-g-PMA can improve the compatibility between PET and E-MA-GMA. • A small amount of PET-g-PMA can enhance the impact strength of PET/E-MA-GMA blend

  8. The Safety and Efficacy of Cell-Assisted Fat Grafting to Traditional Fat Grafting in the Anterior Mid-Face: An Indirect Assessment by 3D Imaging.

    Science.gov (United States)

    Sasaki, Gordon H

    2015-12-01

    Numerous methodologies and algorithms have been suggested to enhance fat graft survival, including the usage of stromal vascular fraction (SVF) and platelet-rich plasma (PRP), but no long-term studies are available. This single-center prospective, case-controlled study investigated the safety and efficacy of combining a modified Baker-designed lateral SMASectomy or plication face lift with simultaneous anterior mid-face grafting into site-specific compartments by (1) conventional Coleman's technique or (2) Yoshimura's cell-assisted lipografting technique. On the voluntary principle, candidates selected one of four techniques for volumization of their mid-face: conventional fat grafting; PRP-assisted fat grafting; SVF-assisted fat grafting; and PRP/SVF- assisted fat grafting. For comparison data, comparable fat volumes, SVF volumes and nucleated cells, and PRP volumes and platelet concentrations were injected into each designated group. Indirect volume retentions were determined by standardized Vectra 3D analyses up to 1 year. PRP, SVF, and PRP/SVF cell supplementation of processed fat resulted in statistically significant percent mean graft retention over their baseline control at 12 months (p facial aesthetic surgery. With refinements in the entire grafting process and the potential benefits of autologous cell approaches with SVF and PRP, future evidence-based controlled studies under regulatory approval may improve graft survival in a safe and effective manner. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  9. Endovascular Retrieval of Entrapped Elephant Trunk Graft During Complex Hybrid Aortic Arch Repair

    Energy Technology Data Exchange (ETDEWEB)

    Damodharan, Karthikeyan, E-mail: drdkarthik@hotmail.com [Singapore General Hospital, Department of Diagnostic Radiology (Singapore); Chao, Victor T. T., E-mail: victor.chao.t.t@singhealth.com.sg [National Heart Centre, Department of Cardiothoracic Surgery (Singapore); Tay, Kiang Hiong, E-mail: tay.kiang.hiong@singhealth.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore)

    2016-12-15

    Entrapment of the elephant trunk graft within the false lumen is a rare complication of surgical repair of an aortic dissection. This is normally retrieved by emergent open surgery. We describe a technique of endovascular retrieval of the dislodged graft, during hybrid aortic arch repair. The elephant trunk was cannulated through and through from a femoral access and the free end of the wire was snared and retrieved from a brachial access. The wire was externalised from both accesses and was used to reposition the graft into the true lumen using a body flossing technique.

  10. Breast Reconstruction after a Bilateral Mastectomy Using the BRAVA Expansion System and Fat Grafting

    Directory of Open Access Journals (Sweden)

    Ondrej Mestak, MD

    2013-11-01

    Full Text Available Summary: Fat graft breast reconstruction following a mastectomy is always limited by the size of the skin envelope, which affects the amount of graft that can be injected in 1 session. Because the fat graft naturally resorbs in all patients, several sessions of fat grafting are necessary. BRAVA’s negative pressure causes a “reverse” expansion of the skin envelope, thus permitting more space for the fat graft. This allows decreasing number of required procedures for an adequate breast reconstruction. We operated on a 38-year-old patient 4 years after bilateral mastectomy without irradiation for breast cancer. Before the procedure, the patient was instructed to wear the BRAVA system for 12 hours daily for 2 months before the first session, at all times between the sessions and for 1 month following the last fat grafting session. We performed 3 fat grafting sessions, as planned. Altogether, we injected 840 cm3 of fat on the right side and 790 cm3 of fat on the left side. Four months after the last operation, the patient was very satisfied with her new breasts. The breasts were soft, with good sensation and a natural feel. Using the BRAVA external expansion system for the enhancement of fat grafting is a suitable technique for breast reconstruction after a mastectomy. This technique produces soft and natural feeling breasts in fewer operative sessions, with a minimal risk of complications. Patient compliance, however, is greatly needed to achieve the desired results.

  11. Effects of therapeutic touch on the vital signs of patients before coronary artery bypass graft surgery.

    Science.gov (United States)

    Zare, Zahra; Shahsavari, Hooman; Moeini, Mahin

    2010-01-01

    Currently healthy heart word considered to be the objective of community health applications in many countries of the world because cardiovascular diseases are the most important factor in mortality of humans, worldwide. Coronary artery bypass graft surgery is one of the most common surgery procedures for these patients. The purpose of this study is to assess the impact of therapeutic touch on medical vital signs of patients before coronary artery bypass graft surgery. The present study is a clinical trial with 44 samples that were selected by easy sampling method and based on two separate lists of random numbers for both men and women; they were divided into two groups. In the therapeutic touch group, intervention therapy was applied on patents for 20 minutes. Data was analyzed using descriptive and inferential statistics. Test results showed that there was a significant difference between the mean pulse rate before and after intervention in both groups (p touch therapy as a safe and effective intervention on the patients which were revealed in this study, this technique can be used as a simple, cheap and applicable technique in all health care centers to help these patients.

  12. Accounting for Technological Change in Regulatory Impact Analyses: The Learning Curve Technique

    Energy Technology Data Exchange (ETD