WorldWideScience

Sample records for immunoprecipitation assays demonstrate

  1. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  2. Testing for myositis specific autoantibodies: Comparison between line blot and immunoprecipitation assays in 57 myositis sera.

    Science.gov (United States)

    Cavazzana, Ilaria; Fredi, Micaela; Ceribelli, Angela; Mordenti, Cristina; Ferrari, Fabio; Carabellese, Nice; Tincani, Angela; Satoh, Minoru; Franceschini, Franco

    2016-06-01

    To analyze the performance of a line blot assay for the identification of autoantibodies in sera of patients affected by myositis, compared with immunoprecipitation (IP) as gold standard. 66 sera of patients with myositis (23 polymyositis, 8 anti-synthetase syndromes, 29 dermatomyositis and 6 overlap syndromes) were tested by commercial LB (Euroimmun, Lubeck, Germany); 57 sera were analyzed also by IP of K562 cell extract radiolabeled with (35)S-methionine. Inter-rater agreement was calculated with Cohen's k coefficient. Myositis-specific antibodies (MSA) were detected in 36/57 sera (63%) by IP and in 39/66 sera (59%) by LB. The most frequent MSA found by LB were anti-Jo1 and anti-Mi2 found in 15% (10/66) of sera, followed by anti-NXP2 and anti-SRP detected in 106% (7/66) of sera. Anti-TIF1gamma and anti-MDA5 were found in 6 (9%) and 5 sera (7.6%), respectively. A good agreement between methods was found only for anti-TIF1γ, anti-MDA5 and anti-NXP-2 antibodies, while a moderate agreement was estimated for anti-Mi2 and anti-EJ. By contrast, a high discordance rate for the detection of anti-Jo1 antibodies was evident (k: 0.3). Multiple positivity for MSA were found in 11/66 (17%) by LB and 0/57 by IP (p: 0001). Comparing the clinical features of these 11 sera, we found total discrepancies between assays in 3 sera (27.3%), a relative discrepancy due to the occurrence of one discordant autoantibody (not confirmed by IP) in 5 cases (45.5%) and a total discrepancy between LB and IP results, but with a relative concordance with clinical features were found in other 3 sera (27.3%). The semiquantitative results do not support the interpretation of the data. The use of LB assay allowed the detection of new MSA, such as anti-MDA5, anti-MJ and anti-TIF1gamma antibodies, previously not found with routine methods. However, the high prevalence of multiple positivities and the high discondant rate of anti-Jo1 antibodies could create some misinterpretation of the results from the

  3. Chromatin Immunoprecipitation Assay for the Identification of Arabidopsis Protein-DNA Interactions In Vivo

    OpenAIRE

    Komar, Dorota N.; Mouriz, Alfonso; Jarillo, José A.; Piñeiro, Manuel

    2016-01-01

    Intricate gene regulatory networks orchestrate biological processes and developmental transitions in plants. Selective transcriptional activation and silencing of genes mediate the response of plants to environmental signals and developmental cues. Therefore, insights into the mechanisms that control plant gene expression are essential to gain a deep understanding of how biological processes are regulated in plants. The chromatin immunoprecipitation (ChIP) technique described here is a proced...

  4. Chromatin Immunoprecipitation Assay for the Identification of Arabidopsis Protein-DNA Interactions In Vivo.

    Science.gov (United States)

    Komar, Dorota N; Mouriz, Alfonso; Jarillo, José A; Piñeiro, Manuel

    2016-01-14

    Intricate gene regulatory networks orchestrate biological processes and developmental transitions in plants. Selective transcriptional activation and silencing of genes mediate the response of plants to environmental signals and developmental cues. Therefore, insights into the mechanisms that control plant gene expression are essential to gain a deep understanding of how biological processes are regulated in plants. The chromatin immunoprecipitation (ChIP) technique described here is a procedure to identify the DNA-binding sites of proteins in genes or genomic regions of the model species Arabidopsis thaliana. The interactions with DNA of proteins of interest such as transcription factors, chromatin proteins or posttranslationally modified versions of histones can be efficiently analyzed with the ChIP protocol. This method is based on the fixation of protein-DNA interactions in vivo, random fragmentation of chromatin, immunoprecipitation of protein-DNA complexes with specific antibodies, and quantification of the DNA associated with the protein of interest by PCR techniques. The use of this methodology in Arabidopsis has contributed significantly to unveil transcriptional regulatory mechanisms that control a variety of plant biological processes. This approach allowed the identification of the binding sites of the Arabidopsis chromatin protein EBS to regulatory regions of the master gene of flowering FT. The impact of this protein in the accumulation of particular histone marks in the genomic region of FT was also revealed through ChIP analysis.

  5. Investigation of histone H4 hyperacetylation dynamics in the 5S rRNA genes family by chromatin immunoprecipitation assay.

    Science.gov (United States)

    Burlibașa, Liliana; Suciu, Ilinca

    2015-12-01

    Oogenesis is a critical event in the formation of female gamete, whose role in development is to transfer genomic information to the next generation. During this process, the gene expression pattern changes dramatically concomitant with genome remodelling, while genomic information is stably maintained. The aim of the present study was to investigate the presence of H4 acetylation of the oocyte and somatic 5S rRNA genes in Triturus cristatus, using chromatin immunoprecipitation assay (ChIP). Our findings suggest that some epigenetic mechanisms such as histone acetylation could be involved in the transcriptional regulation of 5S rRNA gene families.

  6. Chromatin immunoprecipitation assays revealed CREB and serine 133 phospho-CREB binding to the CART gene proximal promoter.

    Science.gov (United States)

    Rogge, George A; Shen, Li-Ling; Kuhar, Michael J

    2010-07-16

    Both over expression of cyclic AMP response element binding protein (CREB) in the nucleus accumbens (NAc), and intra-accumbal injection of cocaine- and amphetamine-regulated transcript (CART) peptides, have been shown to decrease cocaine reward. Also, over expression of CREB in the rat NAc increased CART mRNA and peptide levels, but it is not known if this was due to a direct action of P-CREB on the CART gene promoter. The goal of this study was to test if CREB and P-CREB bound directly to the CRE site in the CART promoter, using chromatin immunoprecipitation (ChIP) assays. ChIP assay with anti-CREB antibodies showed an enrichment of the CART promoter fragment containing the CRE region over IgG precipitated material, a non-specific control. Forskolin, which was known to increase CART mRNA levels in GH3 cells, was utilized to show that the drug increased levels of P-CREB protein and P-CREB binding to the CART promoter CRE-containing region. A region of the c-Fos promoter containing a CRE cis-regulatory element was previously shown to bind P-CREB, and it was used here as a positive control. These data suggest that the effects of CREB over expression on blunting cocaine reward could be, at least in part, attributed to the increased expression of the CART gene by direct interaction of P-CREB with the CART promoter CRE site, rather than by some indirect action. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Immunoprecipitation of Tri-methylated Capped RNA.

    Science.gov (United States)

    Hayes, Karen E; Barr, Jamie A; Xie, Mingyi; Steitz, Joan A; Martinez, Ivan

    2018-02-05

    Cellular quiescence (also known as G 0 arrest) is characterized by reduced DNA replication, increased autophagy, and increased expression of cyclin-dependent kinase p27 Kip1 . Quiescence is essential for wound healing, organ regeneration, and preventing neoplasia. Previous findings indicate that microRNAs (miRNAs) play an important role in regulating cellular quiescence. Our recent publication demonstrated the existence of an alternative miRNA biogenesis pathway in primary human foreskin fibroblast (HFF) cells during quiescence. Indeed, we have identified a group of pri-miRNAs (whose mature miRNAs were found induced during quiescence) modified with a 2,2,7-trimethylguanosine (TMG)-cap by the trimethylguanosine synthase 1 (TGS1) protein and transported to the cytoplasm by the Exportin-1 (XPO1) protein. We used an antibody against (TMG)-caps (which does not cross-react with the (m 7 G)-caps that most pri-miRNAs or mRNAs contain [Luhrmann et al ., 1982]) to perform RNA immunoprecipitations from total RNA extracts of proliferating or quiescent HFFs. The novelty of this assay is the specific isolation of pri-miRNAs as well as other non-coding RNAs containing a TMG-cap modification.

  8. Quantitative Characterization of E-selectin Interaction with Native CD44 and P-selectin Glycoprotein Ligand-1 (PSGL-1) Using a Real Time Immunoprecipitation-based Binding Assay

    KAUST Repository

    Abu Samra, Dina Bashir Kamil; Al Kilani, Alia; Hamdan, Samir; Sakashita, Kosuke; Gadhoum, Samah Z.; Merzaban, Jasmeen

    2015-01-01

    Selectins (E-, P-, and L-selectins) interact with glycoprotein ligands to mediate the essential tethering/rolling step in cell transport and delivery that captures migrating cells from the circulating flow. In this work, we developed a real time immunoprecipitation assay on a surface plasmon resonance chip that captures native glycoforms of two well known E-selectin ligands (CD44/hematopoietic cell E-/L-selectin ligand and P-selectin glycoprotein ligand-1) from hematopoietic cell extracts. Here we present a comprehensive characterization of their binding to E-selectin. We show that both ligands bind recombinant monomeric E-selectin transiently with fast on- and fast off-rates, whereas they bind dimeric E-selectin with remarkably slow onand off-rates. This binding requires the sialyl Lewis x sugar moiety to be placed on both O- and N-glycans, and its association, but not dissociation, is sensitive to the salt concentration. Our results suggest a mechanism through which monomeric selectins mediate initial fast on and fast off kinetics to help capture cells out of the circulating shear flow; subsequently, tight binding by dimeric/oligomeric selectins is enabled to significantly slow rolling. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Quantitative Characterization of E-selectin Interaction with Native CD44 and P-selectin Glycoprotein Ligand-1 (PSGL-1) Using a Real Time Immunoprecipitation-based Binding Assay

    KAUST Repository

    Abu Samra, Dina Bashir Kamil

    2015-06-29

    Selectins (E-, P-, and L-selectins) interact with glycoprotein ligands to mediate the essential tethering/rolling step in cell transport and delivery that captures migrating cells from the circulating flow. In this work, we developed a real time immunoprecipitation assay on a surface plasmon resonance chip that captures native glycoforms of two well known E-selectin ligands (CD44/hematopoietic cell E-/L-selectin ligand and P-selectin glycoprotein ligand-1) from hematopoietic cell extracts. Here we present a comprehensive characterization of their binding to E-selectin. We show that both ligands bind recombinant monomeric E-selectin transiently with fast on- and fast off-rates, whereas they bind dimeric E-selectin with remarkably slow onand off-rates. This binding requires the sialyl Lewis x sugar moiety to be placed on both O- and N-glycans, and its association, but not dissociation, is sensitive to the salt concentration. Our results suggest a mechanism through which monomeric selectins mediate initial fast on and fast off kinetics to help capture cells out of the circulating shear flow; subsequently, tight binding by dimeric/oligomeric selectins is enabled to significantly slow rolling. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  10. Performance in the WIPP nondestructive assay performance demonstration program

    Energy Technology Data Exchange (ETDEWEB)

    Marcinkiewicz, C.J. [Consolidated Technical Services, Inc., Frederick, MD (United States); Connolly, M.J.; Becker, G.K. [Lockheed Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-11-01

    Measurement facilities performing nondestructive assay (NDA) of wastes intended for disposal at the United States Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) are required to demonstrate their ability to meet specific Quality Assurance Objectives (QAOs). This demonstration is performed, in part, by participation in the NDA Performance Demonstration Program (PDP). The PDP is funded and managed by the Carlsbad Area Office (CAO) of DOE and is conducted by the Idaho National Engineering Laboratory. It tests the characteristics of precision, system bias and/or total uncertainty through the measurement of variable, blind combinations of simulated waste drums and certified radioactive standards. Each facility must successfully participate in the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP was completed in July 1996 and the second is scheduled for completion by December 1996. Seven sites reported data in cycle 1 for 11 different measurement systems. This paper describes the design and operation of the PDP and provides the performance data from cycle 1. It also describes the preliminary results from cycle 2 and updates the status and future plans for the NDA PDP. 4 refs., 9 figs., 11 tabs.

  11. Functional coupling between adenosine A1 receptors and G-proteins in rat and postmortem human brain membranes determined with conventional guanosine-5'-O-(3-[35S]thio)triphosphate ([35S]GTPγS) binding or [35S]GTPγS/immunoprecipitation assay.

    Science.gov (United States)

    Odagaki, Yuji; Kinoshita, Masakazu; Ota, Toshio; Meana, J Javier; Callado, Luis F; Matsuoka, Isao; García-Sevilla, Jesús A

    2018-06-01

    Adenosine signaling plays a complex role in multiple physiological processes in the brain, and its dysfunction has been implicated in pathophysiology of neuropsychiatric diseases such as schizophrenia and affective disorders. In the present study, the coupling between adenosine A 1 receptor and G-protein was assessed by means of two [ 35 S]GTPγS binding assays, i.e., conventional filtration method and [ 35 S]GTPγS binding/immunoprecipitation in rat and human brain membranes. The latter method provides information about adenosine A 1 receptor-mediated Gα i-3 activation in rat as well as human brain membranes. On the other hand, adenosine-stimulated [ 35 S]GTPγS binding determined with conventional assay derives from functional activation of Gα i/o proteins (not restricted only to Gα i-3 ) coupled to adenosine A 1 receptors. The determination of adenosine concentrations in the samples used in the present study indicates the possibility that the assay mixture under our experimental conditions contains residual endogenous adenosine at nanomolar concentrations, which was also suggested by the results on the effects of adenosine receptor antagonists on basal [ 35 S]GTPγS binding level. The effects of adenosine deaminase (ADA) on basal binding also support the presence of adenosine. Nevertheless, the varied patterns of ADA discouraged us from adding ADA into assay medium routinely. The concentration-dependent increases elicited by adenosine were determined in 40 subjects without any neuropsychiatric disorders. The increases in %E max values determined by conventional assay according to aging and postmortem delay should be taken into account in future studies focusing on the effects of psychiatric disorders on adenosine A 1 receptor/G-protein interaction in postmortem human brain tissue.

  12. Demonstrating Interactions of Transcription Factors with DNA by Electrophoretic Mobility Shift Assay.

    Science.gov (United States)

    Yousaf, Nasim; Gould, David

    2017-01-01

    Confirming the binding of a transcription factor with a particular DNA sequence may be important in characterizing interactions with a synthetic promoter. Electrophoretic mobility shift assay is a powerful approach to demonstrate the specific DNA sequence that is bound by a transcription factor and also to confirm the specific transcription factor involved in the interaction. In this chapter we describe a method we have successfully used to demonstrate interactions of endogenous transcription factors with sequences derived from endogenous and synthetic promoters.

  13. How-to-do-it: Immunological Assays for the Classroom 1. Enzyme Linked Immunosorbent Assay (ELISA): A Laboratory Tool for Demonstration of Antibody-Antigen Interaction.

    Science.gov (United States)

    Russo, A. J.; And Others

    1984-01-01

    Background information, list of required materials, and procedures are provided for an immunological assay which has been modified for use as a classroom/laboratory demonstration of antigen-antibody reaction. The assay is designed for a two and one-half hour laboratory period but may be modified for one hour laboratories. (JN)

  14. Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) consists of a series of tests conducted on a regular frequency to evaluate the capability for nondestructive assay of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed with TRU waste characterization systems. Measurement facility performance will be demonstrated by the successful analysis of blind audit samples according to the criteria set by this Program Plan. Intercomparison between measurement groups of the DOE complex will be achieved by comparing the results of measurements on similar or identical blind samples reported by the different measurement facilities. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess the performance of measurement groups regarding compliance with established Quality Assurance Objectives (QAOs). As defined for this program, a PDP sample consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components, once manufactured, will be secured and stored at each participating measurement facility designated and authorized by Carlsbad Area Office (CAO) under secure conditions to protect them from loss, tampering, or accidental damage

  15. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2009-01-01

    Each testing and analytical facility performing waste characterization activities for the Waste Isolation Pilot Plant (WIPP) participates in the Performance Demonstration Program (PDP) to comply with the Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC) (DOE/WIPP-02-3122) and the Quality Assurance Program Document (QAPD) (CBFO-94-1012). The PDP serves as a quality control check for data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed to each of the facilities participating in the PDP. The PDP evaluates analyses of simulated headspace gases, constituents of the Resource Conservation and Recovery Act (RCRA), and transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques.

  16. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    DOE Carlsbad Field Office

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the drummed waste PDP, a simulated waste container consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components are distributed to the participating measurement facilities that have been designated and authorized by the Carlsbad Field Office (CBFO). The NDA Drum PDP materials are stored at these sites under secure conditions to

  17. Performance Demonstration Program Plan for Nondestructive Assay of Boxed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP for boxed waste assay systems. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the boxed waste PDP, a simulated waste container consists of a modified standard waste box (SWB) emplaced with radioactive standards and fabricated matrix inserts. An SWB is a waste box with ends designed specifically to fit the TRUPACT-II shipping container. SWB's will be used to package a substantial volume of the TRU waste for disposal. These PDP sample components

  18. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2005-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) is a test program designed to yield data on measurement system capability to characterize drummed transuranic (TRU) waste generated throughout the Department of Energy (DOE) complex. The tests are conducted periodically and provide a mechanism for the independent and objective assessment of NDA system performance and capability relative to the radiological characterization objectives and criteria of the Office of Characterization and Transportation (OCT). The primary documents requiring an NDA PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC), which requires annual characterization facility participation in the PDP, and the Quality Assurance Program Document (QAPD). This NDA PDP implements the general requirements of the QAPD and applicable requirements of the WAC. Measurement facilities must demonstrate acceptable radiological characterization performance through measurement of test samples comprised of pre-specified PDP matrix drum/radioactive source configurations. Measurement facilities are required to analyze the NDA PDP drum samples using the same procedures approved and implemented for routine operational waste characterization activities. The test samples provide an independent means to assess NDA measurement system performance and compliance per criteria delineated in the NDA PDP Plan. General inter-comparison of NDA measurement system performance among DOE measurement facilities and commercial NDA services can also be evaluated using measurement results on similar NDA PDP test samples. A PDP test sample consists of a 55-gallon matrix drum containing a waste matrix type representative of a particular category of the DOE waste inventory and nuclear material standards of known radionuclide and isotopic composition typical of DOE radioactive material. The PDP sample components are made available to participating measurement facilities as designated by the

  19. West Valley Demonstration Project low-level and transuranic waste assay and methodology

    International Nuclear Information System (INIS)

    McVay, C.W.

    1987-03-01

    In the decontamination and decommissioning of the West Valley Nuclear Facility, waste materials are being removed and packaged in a variety of waste containers which require classification in accordance with USNRC 10 CFR 61 and DOE 5820.2 criteria. Low-Level and Transuranic waste assay systems have been developed to efficiently assay and classify the waste packages. The waste is assayed by segmented gamma scanning, passive neutron techniques, dose rate conversion, and/or radiochemical laboratory analysis. The systems are capable of handling all the waste forms currently packaged as part of the Project. The above systems produce a list of nuclides present with their concentrations and determines the classification of the waste packages based on criteria outlined in DOE Order 5820.2 and USNRC 10 CFR 61.55. 9 refs., 12 figs., 8 tabs

  20. Nanodisc-based Co-immunoprecipitation for Mass Spectrometric Identification of Membrane-interacting Proteins

    DEFF Research Database (Denmark)

    Borch-Jensen, Jonas; Roepstorff, Peter; Møller-Jensen, Jakob

    2011-01-01

    enterotoxigenic Escherischia coli, GM1-nanodiscs were employed for co-immunoprecipitation. The B subunit of heat labile enterotoxin was identified as a specific interaction partner by mass spectrometry, thus demonstrating that nanodisc technology is useful for highly specific detection and identification...

  1. Preferential microRNA targeting revealed by in vivo competitive binding and differential Argonaute immunoprecipitation.

    Science.gov (United States)

    Werfel, Stanislas; Leierseder, Simon; Ruprecht, Benjamin; Kuster, Bernhard; Engelhardt, Stefan

    2017-09-29

    MicroRNAs (miRNAs) have been described to simultaneously inhibit hundreds of targets, albeit to a modest extent. It was recently proposed that there could exist more specific, exceptionally strong binding to a subgroup of targets. However, it is unknown, whether this is the case and how such targets can be identified. Using Argonaute2-ribonucleoprotein immunoprecipitation and in vivo competitive binding assays, we demonstrate for miRNAs-21, -199-3p and let-7 exceptional regulation of a subset of targets, which are characterized by preferential miRNA binding. We confirm this finding by analysis of independent quantitative proteome and transcriptome datasets obtained after miRNA silencing. Our data suggest that mammalian miRNA activity is guided by preferential binding of a small set of 3'-untranslated regions, thereby shaping a steep gradient of regulation between potential targets. Our approach can be applied for transcriptome-wide identification of such targets independently of the presence of seed complementary sequences or other predictors. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin.

    LENUS (Irish Health Repository)

    Byrne, Brendan

    2010-02-01

    Commercially available prolactin immunoassays detect macroprolactin to variable degrees. Best practice requires laboratories to assess the cross-reactivity of their prolactin assay with macroprolactin, and where appropriate, introduce a screen for the presence of macroprolactin. Our policy has been to reanalyse hyperprolactinaemic samples following polyethylene glycol (PEG) precipitation and to report the resultant value as the monomeric prolactin content of the sample. The goal of this study was to determine the need to continue PEG precipitation when prolactin measurements with the Wallac AutoDELFIA were replaced by the Beckman DxI 800.

  3. Methylated DNA Immunoprecipitation Analysis of Mammalian Endogenous Retroviruses.

    Science.gov (United States)

    Rebollo, Rita; Mager, Dixie L

    2016-01-01

    Endogenous retroviruses are repetitive sequences found abundantly in mammalian genomes which are capable of modulating host gene expression. Nevertheless, most endogenous retrovirus copies are under tight epigenetic control via histone-repressive modifications and DNA methylation. Here we describe a common method used in our laboratory to detect, quantify, and compare mammalian endogenous retrovirus DNA methylation. More specifically we describe methylated DNA immunoprecipitation (MeDIP) followed by quantitative PCR.

  4. Studying RNA-protein interactions in vivo by RNA immunoprecipitation

    DEFF Research Database (Denmark)

    Selth, Luke A; Close, Pierre; Svejstrup, Jesper Q

    2011-01-01

    and have significant effects on gene expression. RNA immunoprecipitation (RIP) is a powerful technique used to detect direct and indirect interactions between individual proteins and specific RNA molecules in vivo. Here, we describe RIP methods for both yeast and mammalian cells.......The crucial roles played by RNA-binding proteins in all aspects of RNA metabolism, particularly in the regulation of transcription, have become increasingly evident. Moreover, other factors that do not directly interact with RNA molecules can nevertheless function proximally to RNA polymerases...

  5. Complete validation of a unique digestion assay to detect Trichinella larvae in horse meat demonstrates the reliability of this assay for meeting food safety and trade requirements.

    Science.gov (United States)

    Forbes, L B; Hill, D E; Parker, S; Tessaro, S V; Gamble, H R; Gajadhar, A A

    2008-03-01

    A tissue digestion assay using a double separatory funnel procedure for the detection of Trichinella larvae in horse meat was validated for application in food safety programs and trade. The assay consisted of a pepsin-HCl digestion step to release larvae from muscle tissue and two sequential sedimentation steps in separatory funnels to recover and concentrate larvae for detection with a stereomicroscope. With defined critical control points, the assay was conducted within a quality assurance system compliant with International Organization for Standardization-International Electrotechnical Commission (ISO/IEC) 17025 guidelines. Samples used in the validation were obtained from horses experimentally infected with Trichinella spiralis to obtain a range of muscle larvae densities. One-, 5-, and 10-g samples of infected tissue were combined with 99, 95, and 90 g, respectively, of known negative horse tissue to create a 100-g sample for testing. Samples of 5 and 10 g were more likely to be positive than were 1-g samples when larval densities were less than three larvae per gram (lpg). This difference is important because ingested meat with 1 lpg is considered the threshold for clinical disease in humans. Using a 5-g sample size, all samples containing 1.3 to 2 lpg were detected, and 60 to 100% of samples with infected horse meat containing 0.1 to 0.7 lpg were detected. In this study, the double separatory funnel digestion assay was efficient and reliable for its intended use in food safety and trade. This procedure is the only digestion assay for Trichinella in horse meat that has been validated as consistent and effective at critical levels of sensitivity.

  6. Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.

    Science.gov (United States)

    Gelpí, Carmen; Pérez, Elena; Roldan, Cristina

    2014-09-01

    The aim of this study was to compare the degree of agreement of a novel Zenit RA chemiluminescent immunoassay (CLIA) from A. Menarini Diagnostics (Florence, Italy) and the gold standard immunoprecipitation assay to screen for the presence of specific anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl-70(Topo I) antibodies. We studied 114 sera, 98 from patients with well-defined autoimmune connective tissue diseases and 16 from blood donor volunteers. All samples were fully characterized using the new chemiluminescent immunoassay and immunoprecipitation. In addition, all the samples were analyzed by indirect immunofluorescence (IIF) and anti-Scl-70(Topo I) antibodies were analyzed by immunoblot (IB) assay. Discrepant samples were analyzed using a commercial dot blot technique (Recomline from Mikrogen). The simple Kappa coefficient was used to measure the level of agreement between the results of Zenit RA CLIA and the gold standard. The Kappa agreement between Zenit RA CLIA and gold standard immunoprecipitation, as well as IB and IIFassays for the presence of anti-Scl-70(Topo I)(0.948) was excellent. The concordance between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-U1snRNP (0.883), anti-Ro/SS-A (0.878), anti-Jo-1((his)tRNA-Synthetase) (0.791) and anti-Sm (0.786) was good, and excellent when the cut-off was raised to 14 U/ml (arbitrary units/ml). Between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-La/SS-B, the Kappa agreement had a value of 0.689, but this improved to 0.775 when the cut-off was raised to14 U/ml. Precision was good based on the evaluation of replicate samples. Inter-assay coefficient variation was lower than 3.4 % (CV in %) in all the kits and <1.2 % (CV in  %) for intra-assay measurements. Our findings show that Zenit RA CLIA was specific and sensitive to detect anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his

  7. Radiometric measurements on the fabrication of non-destructive assay standards for WIPP-Performance Demonstration Program

    International Nuclear Information System (INIS)

    Wong, A.S.; Marshall, R.S.

    1997-04-01

    The Inorganic Elemental Analysis Group of LANL has prepared several different sets of working reference materials (WRMs). These WRMs are prepared by blending quantities of nuclear materials (plutonium, americium, and enriched uranium) with diatomaceous earth. The blends are encapsulated in stainless steel cylinders. These WRMs are being measured as blind controls in neutron and gamma based non-destructive assay (NDA) instruments. Radiometric measurements on the blending homogeneity and verification on a set of sixty three plutonium based WRMs are discussed in this paper

  8. Chromatin immunoprecipitation to analyze DNA binding sites of HMGA2.

    Directory of Open Access Journals (Sweden)

    Nina Winter

    Full Text Available BACKGROUND: HMGA2 is an architectonic transcription factor abundantly expressed during embryonic and fetal development and it is associated with the progression of malignant tumors. The protein harbours three basically charged DNA binding domains and an acidic protein binding C-terminal domain. DNA binding induces changes of DNA conformation and hence results in global overall change of gene expression patterns. Recently, using a PCR-based SELEX (Systematic Evolution of Ligands by Exponential Enrichment procedure two consensus sequences for HMGA2 binding have been identified. METHODOLOGY/PRINCIPAL FINDINGS: In this investigation chromatin immunoprecipitation (ChIP experiments and bioinformatic methods were used to analyze if these binding sequences can be verified on chromatin of living cells as well. CONCLUSION: After quantification of HMGA2 protein in different cell lines the colon cancer derived cell line HCT116 was chosen for further ChIP experiments because of its 3.4-fold higher HMGA2 protein level. 49 DNA fragments were obtained by ChIP. These fragments containing HMGA2 binding sites have been analyzed for their AT-content, location in the human genome and similarities to sequences generated by a SELEX study. The sequences show a significantly higher AT-content than the average of the human genome. The artificially generated SELEX sequences and short BLAST alignments (11 and 12 bp of the ChIP fragments from living cells show similarities in their organization. The flanking regions are AT-rich, whereas a lower conservation is present in the center of the sequences.

  9. An improved behavioural assay demonstrates that ultrasound vocalizations constitute a reliable indicator of chronic cancer pain and neuropathic pain

    Directory of Open Access Journals (Sweden)

    Selvaraj Deepitha

    2010-03-01

    Full Text Available Abstract Background On-going pain is one of the most debilitating symptoms associated with a variety of chronic pain disorders. An understanding of mechanisms underlying on-going pain, i.e. stimulus-independent pain has been hampered so far by a lack of behavioural parameters which enable studying it in experimental animals. Ultrasound vocalizations (USVs have been proposed to correlate with pain evoked by an acute activation of nociceptors. However, literature on the utility of USVs as an indicator of chronic pain is very controversial. A majority of these inconsistencies arise from parameters confounding behavioural experiments, which include novelty, fear and stress due to restrain, amongst others. Results We have developed an improved assay which overcomes these confounding factors and enables studying USVs in freely moving mice repetitively over several weeks. Using this improved assay, we report here that USVs increase significantly in mice with bone metastases-induced cancer pain or neuropathic pain for several weeks, in comparison to sham-treated mice. Importantly, analgesic drugs which are known to alleviate tumour pain or neuropathic pain in human patients significantly reduce USVs as well as mechanical allodynia in corresponding mouse models. Conclusions We show that studying USVs and mechanical allodynia in the same cohort of mice enables comparing the temporal progression of on-going pain (i.e. stimulus-independent pain and stimulus-evoked pain in these clinically highly-relevant forms of chronic pain.

  10. Demonstration of extracellular peptidylarginine deiminase (PAD) activity in synovial fluid of patients with rheumatoid arthritis using a novel assay for citrullination of fibrinogen

    DEFF Research Database (Denmark)

    Damgaard, Dres; Senolt, Ladislav; Nielsen, Michael Friberg

    2014-01-01

    INTRODUCTION: Members of the peptidylarginine deiminase (PAD) family catalyse the posttranslational conversion of peptidylarginine to peptidylcitrulline. Citrullination of proteins is well described in rheumatoid arthritis (RA), and hypercitrullination of proteins may be related to inflammation...... in general. PAD activity has been demonstrated in various cell lysates, but so far not in synovial fluid. We aimed to develop an assay for detection of PAD activity, if any, in synovial fluid from RA patients. METHODS: An enzyme-linked immunosorbent assay using human fibrinogen as the immobilized substrate...... for citrullination and anti-citrullinated fibrinogen antibody as the detecting agent were used for measurement of PAD activity in synovial fluid samples from five RA patients. The concentrations of PAD2 and calcium were also determined. RESULTS: Approximately 150 times lower levels of recombinant human PAD2 (rhPAD2...

  11. Design of benign matrix drums for the non-destructive assay performance demonstration program for the National TRU Program

    International Nuclear Information System (INIS)

    Becker, G.K.

    1996-09-01

    Regulatory compliance programs associated with the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) require the collection of waste characterization data of known quality to support repository performance assessment, permitting, and associated activities. Blind audit samples, referred to as PDP (performance demonstration program) samples, are devices used in the NDA PDP program to acquire waste NDA system performance data per defined measurement routines. As defined under the current NDA PDP Program Plan, a PDP sample consists of a DOT 17C 55-gallon PDP matrix drum configured with insertable radioactive standards, working reference materials (WRMs). The particular manner in which the matrix drum and PDP standard(s) are combined is a function of the waste NDA system performance test objectives of a given cycle. The scope of this document is confined to the design of the PDP drum radioactive standard internal support structure, the matrix type and the as installed configuration. The term benign is used to designate a matrix possessing properties which are nominally non-interfering to waste NDA measurement techniques. Measurement interference sources are technique specific but include attributes such as: high matrix density, heterogeneous matrix distributions, matrix compositions containing high moderator/high Z element concentrations, etc. To the extent practicable the matrix drum design should not unduly bias one NDA modality over another due to the manner in which the matrix drum configuration manifests itself to the measurement system. To this end the PDP matrix drum configuration and composition detailed below is driven primarily by the intent to minimize the incorporation of matrix attributes known to interfere with fundamental waste NDA modalities, i.e. neutron and gamma based techniques

  12. Genomic response to Wnt signalling is highly context-dependent - Evidence from DNA microarray and chromatin immunoprecipitation screens of Wnt/TCF targets

    International Nuclear Information System (INIS)

    Railo, Antti; Pajunen, Antti; Itaeranta, Petri; Naillat, Florence; Vuoristo, Jussi; Kilpelaeinen, Pekka; Vainio, Seppo

    2009-01-01

    Wnt proteins are important regulators of embryonic development, and dysregulated Wnt signalling is involved in the oncogenesis of several human cancers. Our knowledge of the downstream target genes is limited, however. We used a chromatin immunoprecipitation-based assay to isolate and characterize the actual gene segments through which Wnt-activatable transcription factors, TCFs, regulate transcription and an Affymetrix microarray analysis to study the global transcriptional response to the Wnt3a ligand. The anti-β-catenin immunoprecipitation of DNA-protein complexes from mouse NIH3T3 fibroblasts expressing a fusion protein of β-catenin and TCF7 resulted in the identification of 92 genes as putative TCF targets. GeneChip assays of gene expression performed on NIH3T3 cells and the rat pheochromocytoma cell line PC12 revealed 355 genes in NIH3T3 and 129 genes in the PC12 cells with marked changes in expression after Wnt3a stimulus. Only 2 Wnt-regulated genes were shared by both cell lines. Surprisingly, Disabled-2 was the only gene identified by the chromatin immunoprecipitation approach that displayed a marked change in expression in the GeneChip assay. Taken together, our approaches give an insight into the complex context-dependent nature of Wnt pathway transcriptional responses and identify Disabled-2 as a potential new direct target for Wnt signalling.

  13. Immunoprecipitation techniques and Elisa in the detection of anti-Fonsecaea pedrosoi antibodies in chromoblastomycosis

    Directory of Open Access Journals (Sweden)

    Vidal Mônica Scarpelli Martinelli

    2003-01-01

    Full Text Available Chromoblastomycosis (CBM is a chronic subcutaneous infection caused by several dematiaceous fungi. The most commonly etiological agent found in Brazil is Fonsecaea pedrosoi, which appears as thick walled, brownish colored cells with transverse and longitudinal division in the lesions, called "muriform cells". This disease is found worldwide but countries like Madagascar and Brazil have highest incidence. Diagnosis is made by clinical, direct and histopathologic examination and culture of specimens. Serological tests have been used to identify specific antibodies against Fonsecaea pedrosoi antigens, as well as immunotechniques have been used for CBM serological identification and diagnosis. In the present study double immunodiffusion (DID, counterimmunoelectrophoresis (CIE and immunoenzymatic test (ELISA have been used to evaluate humoral immune response in patients with CBM caused by F. pedrosoi. Metabolic antigen was used for immunoprecipitation tests (DID and CIE while somatic antigen for ELISA. Our results demonstrated 53% sensitivity and 96% specificity for DID, while CIE presented 68% sensitivity and 90.5% specificity. ELISA demonstrated 78% sensibility and 83% specificity. Serological tests can be a useful tool to study different aspects of CBM, such as helping differential diagnosis, when culture of the pathogenic agent is impossible.

  14. A novel mitochondrial protein of Neurospora crassa immunoprecipitates with known enzyme subunits but is not antigenic

    International Nuclear Information System (INIS)

    Nixon, E.

    1989-01-01

    14 C labeled 4'-phosphopantetheine (PAN) is detectable as 2 bands after SDS-PAGE of mitochondrial proteins. The bands comigrate with subunit 6 of cytochrome oxidase (COX) and a small ATPase subunit in tube gel slices of immunoprecipitates. However, other work demonstrated these bands to be due to modification of a novel protein, related to acyl carrier protein (ACP) of spinach and E. coli, that exists in two forms. To resolve this discrepancy, 1-dimensional (1D) slab and 2-dimensional (2D) SDS-PAGE was used for increased resolution over tube gels. Total mitochondrial protein gels from PAN labeled cells were western blotted, probed for COX, and autoradiographed. In 1D there is exact migration of PAN with COX6. In 2D PAN overlaps a protein distinct from and not antigenically related to COX subunits. These data suggest it is the ACP-like protein that in PAN-modified. Its possible association with COX during assembly will be discussed

  15. Validation of commercially available sphingosine kinase 2 antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Heidi A. Neubauer

    2017-03-01

    Full Text Available Sphingosine kinase 2 (SK2 is a ubiquitously expressed lipid kinase that has important, albeit complex and poorly understood, roles in regulating cell survival and cell death. In addition to being able to promote cell cycle arrest and apoptosis under certain conditions, it has recently been shown that SK2 can promote neoplastic transformation and tumorigenesis in vivo. Therefore, well validated and reliable tools are required to study and better understand the true functions of SK2. Here, we compare two commercially available SK2 antibodies: a rabbit polyclonal antibody from Proteintech that recognizes amino acids 266-618 of human SK2a, and a rabbit polyclonal antibody from ECM Biosciences that recognizes amino acids 36-52 of human SK2a. We examine the performance of these antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence staining of endogenous SK2, using human HEK293 and HeLa cell lines, as well as mouse embryonic fibroblasts (MEFs. Furthermore, we assess the specificity of these antibodies to the target protein through the use of siRNA-mediated SK2 knockdown and SK2 knockout (Sphk2-/- MEFs. Our results demonstrate that the Proteintech anti-SK2 antibody reproducibly displayed superior sensitivity and selectivity towards SK2 in immunoblot analyses, while the ECM Biosciences anti-SK2 antibody was reproducibly superior for SK2 immunoprecipitation and detection by immunofluorescence staining. Notably, both antibodies produced non-specific bands and staining in the MEFs, which was not observed with the human cell lines. Therefore, we conclude that the Proteintech SK2 antibody is a valuable reagent for use in immunoblot analyses, and the ECM Biosciences SK2 antibody is a useful tool for SK2 immunoprecipitation and immunofluorescence staining, at least in the human cell lines employed in this study.

  16. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong [Korea Atomic Energy Research Institute, Daejeong (Korea, Republic of)

    2016-01-11

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  17. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    International Nuclear Information System (INIS)

    Henzlova, D.; Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J.; Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong

    2016-01-01

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  18. Isotope coded protein labeling coupled immunoprecipitation (ICPL-IP): a novel approach for quantitative protein complex analysis from native tissue.

    Science.gov (United States)

    Vogt, Andreas; Fuerholzner, Bettina; Kinkl, Norbert; Boldt, Karsten; Ueffing, Marius

    2013-05-01

    High confidence definition of protein interactions is an important objective toward the understanding of biological systems. Isotope labeling in combination with affinity-based isolation of protein complexes has increased in accuracy and reproducibility, yet, larger organisms--including humans--are hardly accessible to metabolic labeling and thus, a major limitation has been its restriction to small animals, cell lines, and yeast. As composition as well as the stoichiometry of protein complexes can significantly differ in primary tissues, there is a great demand for methods capable to combine the selectivity of affinity-based isolation as well as the accuracy and reproducibility of isotope-based labeling with its application toward analysis of protein interactions from intact tissue. Toward this goal, we combined isotope coded protein labeling (ICPL)(1) with immunoprecipitation (IP) and quantitative mass spectrometry (MS). ICPL-IP allows sensitive and accurate analysis of protein interactions from primary tissue. We applied ICPL-IP to immuno-isolate protein complexes from bovine retinal tissue. Protein complexes of immunoprecipitated β-tubulin, a highly abundant protein with known interactors as well as the lowly expressed small GTPase RhoA were analyzed. The results of both analyses demonstrate sensitive and selective identification of known as well as new protein interactions by our method.

  19. Isotope Coded Protein Labeling Coupled Immunoprecipitation (ICPL-IP): A Novel Approach for Quantitative Protein Complex Analysis From Native Tissue*

    Science.gov (United States)

    Vogt, Andreas; Fuerholzner, Bettina; Kinkl, Norbert; Boldt, Karsten; Ueffing, Marius

    2013-01-01

    High confidence definition of protein interactions is an important objective toward the understanding of biological systems. Isotope labeling in combination with affinity-based isolation of protein complexes has increased in accuracy and reproducibility, yet, larger organisms—including humans—are hardly accessible to metabolic labeling and thus, a major limitation has been its restriction to small animals, cell lines, and yeast. As composition as well as the stoichiometry of protein complexes can significantly differ in primary tissues, there is a great demand for methods capable to combine the selectivity of affinity-based isolation as well as the accuracy and reproducibility of isotope-based labeling with its application toward analysis of protein interactions from intact tissue. Toward this goal, we combined isotope coded protein labeling (ICPL)1 with immunoprecipitation (IP) and quantitative mass spectrometry (MS). ICPL-IP allows sensitive and accurate analysis of protein interactions from primary tissue. We applied ICPL-IP to immuno-isolate protein complexes from bovine retinal tissue. Protein complexes of immunoprecipitated β-tubulin, a highly abundant protein with known interactors as well as the lowly expressed small GTPase RhoA were analyzed. The results of both analyses demonstrate sensitive and selective identification of known as well as new protein interactions by our method. PMID:23268931

  20. Accounting for immunoprecipitation efficiencies in the statistical analysis of ChIP-seq data

    NARCIS (Netherlands)

    Bao, Yanchun; Vinciotti, Veronica; Wit, Ernst; 't Hoen, Peter A C

    2013-01-01

    Background: ImmunoPrecipitation (IP) efficiencies may vary largely between different antibodies and between repeated experiments with the same antibody. These differences have a large impact on the quality of ChIP-seq data: a more efficient experiment will necessarily lead to a higher signal to

  1. Quality Improvement to Demonstrate the Lack of Reliability of the Human Papillomavirus mRNA Assay to Identify Women With Latent Human Papillomavirus Infections.

    Science.gov (United States)

    Cotton, Sarah; Brown, Robert E; Nugent, Elizabeth K; Robazetti, Sonia C; Berens, Pamela D; Smith, Judith A

    2018-04-01

    To assess the consistency between human papillomavirus (HPV) mRNA testing in women with a history of previous HPV infections diagnosed by HPV DNA assay and the potential effects on follow-up HPV screening. This was a quality improvement study that used data from a pathology laboratory software database reviewed from November 2014 to June 2016 to identify female patients aged 30 years or older with greater than one HPV-positive result, including one or more HPV mRNA assay results and one or more documented HPV DNA assay results for comparison. Previous correlative cytology and colposcopic histopathology were also documented. American College of Obstetricians and Gynecologists' cervical cancer screening guidelines were used to compare potential differences in follow-up recommendations. Four hundred twenty-five charts for female patients 30 years of age or older were identified with one or more prior high-risk HPV infections by DNA assay. There was a 69.3% difference in HPV mRNA results compared with previous HPV DNA-positive results. There was a potential change in follow-up for 71.7% of patients with one prior high-risk-HPV-positive result and 60.0% of patients with two or more prior high-risk HPV-positive results. There were 231 colposcopy reports evaluated in this study. Of these, 62 (26.8%) were abnormal colposcopy reports, including 45 low-grade squamous intraepithelial lesions, 15 high-grade squamous intraepithelial lesions, and two cancers. Twenty-five (40.3%) abnormal colposcopy findings were in patients with a history of at least than two prior HPV DNA-positive results and a report of currently being HPV-negative with the mRNA assay. The HPV mRNA assays are less sensitive for detection of latent HPV infections compared with HPV DNA assays. Based on these data and the potential change in follow-up care, the HPV mRNA assay should not be used for a primary screening tool for cervical cancer. Many pathology laboratories have shifted to using the HPV mRNA assay

  2. Genome-Wide Methylated DNA Immunoprecipitation Analysis of Patients with Polycystic Ovary Syndrome

    OpenAIRE

    Shen, Hao-ran; Qiu, Li-hua; Zhang, Zhi-qing; Qin, Yuan-yuan; Cao, Cong; Di, Wen

    2013-01-01

    Polycystic ovary syndrome (PCOS) is a complex, heterogeneous disorder of uncertain etiology. Recent studies suggested that insulin resistance (IR) plays an important role in the development of PCOS. In the current study, we aimed to investigate the molecular mechanism of IR in PCOS. We employed genome-wide methylated DNA immunoprecipitation (MeDIP) analysis to characterize genes that are differentially methylated in PCOS patients vs. healthy controls. Besides, we also identified the different...

  3. A Bayesian deconvolution strategy for immunoprecipitation-based DNA methylome analysis

    Science.gov (United States)

    Down, Thomas A.; Rakyan, Vardhman K.; Turner, Daniel J.; Flicek, Paul; Li, Heng; Kulesha, Eugene; Gräf, Stefan; Johnson, Nathan; Herrero, Javier; Tomazou, Eleni M.; Thorne, Natalie P.; Bäckdahl, Liselotte; Herberth, Marlis; Howe, Kevin L.; Jackson, David K.; Miretti, Marcos M.; Marioni, John C.; Birney, Ewan; Hubbard, Tim J. P.; Durbin, Richard; Tavaré, Simon; Beck, Stephan

    2009-01-01

    DNA methylation is an indispensible epigenetic modification of mammalian genomes. Consequently there is great interest in strategies for genome-wide/whole-genome DNA methylation analysis, and immunoprecipitation-based methods have proven to be a powerful option. Such methods are rapidly shifting the bottleneck from data generation to data analysis, necessitating the development of better analytical tools. Until now, a major analytical difficulty associated with immunoprecipitation-based DNA methylation profiling has been the inability to estimate absolute methylation levels. Here we report the development of a novel cross-platform algorithm – Bayesian Tool for Methylation Analysis (Batman) – for analyzing Methylated DNA Immunoprecipitation (MeDIP) profiles generated using arrays (MeDIP-chip) or next-generation sequencing (MeDIP-seq). The latter is an approach we have developed to elucidate the first high-resolution whole-genome DNA methylation profile (DNA methylome) of any mammalian genome. MeDIP-seq/MeDIP-chip combined with Batman represent robust, quantitative, and cost-effective functional genomic strategies for elucidating the function of DNA methylation. PMID:18612301

  4. Immunoprecipitation assay of alpha-fetoprotein synthesis by cultured mouse hepatoma cells treated with estrogens and glucocorticoids.

    Science.gov (United States)

    Rosebrock, J A; Parker, C L; Kute, T E

    1981-01-01

    This investigation was to study the biosynthesis of 3H-labeled alpha-fetoprotein (AFP) by cultured mouse hepatoma (HEPA-2) cells. Both the function and regulation of this oncodevelopmental gene are unknown. However, evidence indicates that mechanisms controlling the expression of AFP involve aspects of both normal embryonic development and neoplastic transformation. the secretion of AFP was analyzed during different phases of the growth cycle to provide information on AFP production using standard culture conditions. The highest rate of secretion occurred during the stationary phase, followed by the late logarithmic and early logarithmic phases of growth, respectively. The production of AFP was then determined following the addition of glucocorticoids and estrogens in an attempt to understand hormonal factors that may be involved. Studies utilizing estradiol-17 beta indicated that the secretion of AFP did not appear to be sensitive to this steroid even though sucrose density gradient analysis of HEPA-2 cytosol, for estrogenic receptors, revealed competitive binding moieties on the 8S and 4S regions of the gradient. In contrast, the secretion of the total complement of proteins, including AFP, was significantly stimulated by the glucocorticoids, dexamethasone and corticosterone. Analysis of HEPA-2 cytosol for glucocorticoid receptors revealed binding components in the 7S and 3-4S regions of the gradient. The 3H-dexamethasone binding appeared to be stereospecific since nonlabeled dexamethasone, but not nonlabeled estradiol-17 beta, effectively displaced the bound radioactivity. The glucocorticoid-binding component in HEPA-2 therefore displayed characteristics reported for glucocorticoid receptors in normal liver and other hepatomas.

  5. A simple quantitative protein A micro-immunoprecipitation method; assay of antibodies to the N and H antigens of poliovirus

    International Nuclear Information System (INIS)

    Vrijsen, R.; Rombaut, B.; Boeye, A.

    1983-01-01

    Staphylococcus aureus (Cowan strain I) was used to absorb immune complexes from antiserum to poliovirus to which labeled N or H poliovirus antigens had been added, and the radioactivity in the pelleted organisms and in the supernatant was measured. Excellent agreement was obtained between values calculated separately from the pellet and supernatant readings, validating the use of supernatant measurements from a microtitration plate method. (Auth.)

  6. Simple quantitative protein A micro-immunoprecipitation method; assay of antibodies to the N and H antigens of poliovirus

    Energy Technology Data Exchange (ETDEWEB)

    Vrijsen, R.; Rombaut, B.; Boeye, A. (Brussels Univ. (Belgium))

    1983-04-29

    Staphylococcus aureus (Cowan strain I) was used to absorb immune complexes from antiserum to poliovirus to which labeled N or H poliovirus antigens had been added, and the radioactivity in the pelleted organisms and in the supernatant was measured. Excellent agreement was obtained between values calculated separately from the pellet and supernatant readings, validating the use of supernatant measurements from a microtitration plate method.

  7. Protein p53 Binding to Cisplatin-modified DNA Targets Evaluated by Modification-specific Electrochemical Immunoprecipitation Assay

    Czech Academy of Sciences Publication Activity Database

    Tichý, Vlastimil; Šebest, Peter; Orság, Petr; Havran, Luděk; Pivoňková, Hana; Fojta, Miroslav

    2017-01-01

    Roč. 29, č. 2 (2017), s. 319-323 ISSN 1040-0397 R&D Projects: GA ČR GAP206/11/1638 Institutional support: RVO:68081707 Keywords : catalytic hydrogen evolution * probe * mechanism * suggest Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis) Impact factor: 2.851, year: 2016

  8. A Filtration-based Method of Preparing High-quality Nuclei from Cross-linked Skeletal Muscle for Chromatin Immunoprecipitation.

    Science.gov (United States)

    Nohara, Kazunari; Chen, Zheng; Yoo, Seung-Hee

    2017-07-06

    Chromatin immunoprecipitation (ChIP) is a powerful method to determine protein binding to chromatin DNA. Fiber-rich skeletal muscle, however, has been a challenge for ChIP due to technical difficulty in isolation of high-quality nuclei with minimal contamination of myofibrils. Previous protocols have attempted to purify nuclei before cross-linking, which incurs the risk of altered DNA-protein interaction during the prolonged nuclei preparation process. In the current protocol, we first cross-linked the skeletal muscle tissue collected from mice, and the tissues were minced and sonicated. Since we found that ultracentrifugation was not able to separate nuclei from myofibrils using cross-linked muscle tissue, we devised a sequential filtration procedure to obtain high-quality nuclei devoid of significant myofibril contamination. We subsequently prepared chromatin by using an ultrasonicator, and ChIP assays with anti-BMAL1 antibody revealed robust circadian binding pattern of BMAL1 to target gene promoters. This filtration protocol constitutes an easily applicable method to isolate high-quality nuclei from cross-linked skeletal muscle tissue, allowing consistent sample processing for circadian and other time-sensitive studies. In combination with next-generation sequencing (NGS), our method can be deployed for various mechanistic and genomic studies focusing on skeletal muscle function.

  9. Screening of antifungal azole drugs and agrochemicals with an adapted alamarBlue-based assay demonstrates antibacterial activity of croconazole against Mycobacterium ulcerans.

    Science.gov (United States)

    Scherr, Nicole; Röltgen, Katharina; Witschel, Matthias; Pluschke, Gerd

    2012-12-01

    An alamarBlue-based growth inhibition assay has been adapted for the thermosensitive and slow-growing pathogen Mycobacterium ulcerans. The standardized test procedure enables medium-throughput screening of preselected compound libraries. Testing of a set of 48 azoles with known antifungal activity led to the identification of an imidazole antifungal displaying an inhibitory dose (ID) of 9 μM for M. ulcerans.

  10. Protocol: methodology for chromatin immunoprecipitation (ChIP in Chlamydomonas reinhardtii

    Directory of Open Access Journals (Sweden)

    Strenkert Daniela

    2011-11-01

    Full Text Available Abstract We report on a detailed chromatin immunoprecipitation (ChIP protocol for the unicellular green alga Chlamydomonas reinhardtii. The protocol is suitable for the analysis of nucleosome occupancy, histone modifications and transcription factor binding sites at the level of mononucleosomes for targeted and genome-wide studies. We describe the optimization of conditions for crosslinking, chromatin fragmentation and antibody titer determination and provide recommendations and an example for the normalization of ChIP results as determined by real-time PCR.

  11. Real-time single-molecule co-immunoprecipitation analyses reveal cancer-specific Ras signalling dynamics

    Science.gov (United States)

    Lee, Hong-Won; Kyung, Taeyoon; Yoo, Janghyun; Kim, Tackhoon; Chung, Chaeuk; Ryu, Ji Young; Lee, Hanki; Park, Kihyun; Lee, Sangkyu; Jones, Walton D.; Lim, Dae-Sik; Hyeon, Changbong; Do Heo, Won; Yoon, Tae-Young

    2013-01-01

    Co-immunoprecipitation (co-IP) has become a standard technique, but its protein-band output provides only static, qualitative information about protein–protein interactions. Here we demonstrate a real-time single-molecule co-IP technique that generates real-time videos of individual protein–protein interactions as they occur in unpurified cell extracts. By analysing single Ras–Raf interactions with a 50-ms time resolution, we have observed transient intermediates of the protein–protein interaction and determined all the essential kinetic rates. Using this technique, we have quantified the active fraction of native Ras proteins in xenograft tumours, normal tissue and cancer cell lines. We demonstrate that the oncogenic Ras mutations selectively increase the active-Ras fraction by one order of magnitude, without affecting total Ras levels or single-molecule signalling kinetics. Our approach allows us to probe the previously hidden, dynamic aspects of weak protein–protein interactions. It also suggests a path forward towards precision molecular diagnostics at the protein–protein interaction level. PMID:23422673

  12. Strong interferon-gamma mediated cellular immunity to scrub typhus demonstrated using a novel whole cell antigen ELISpot assay in rhesus macaques and humans.

    Directory of Open Access Journals (Sweden)

    Manutsanun Sumonwiriya

    2017-09-01

    Full Text Available Scrub typhus is a febrile infection caused by the obligate intracellular bacterium Orientia tsutsugamushi, which causes significant morbidity and mortality across the Asia-Pacific region. The control of this vector-borne disease is challenging due to humans being dead-end hosts, vertical maintenance of the pathogen in the vector itself, and a potentially large rodent reservoir of unclear significance, coupled with a lack of accurate diagnostic tests. Development of an effective vaccine is highly desirable. This however requires better characterization of the natural immune response of this neglected but important disease. Here we implement a novel IFN-γ ELISpot assay as a tool for studying O. tsutsugamushi induced cellular immune responses in an experimental scrub typhus rhesus macaque model and human populations. Whole cell antigen for O. tsutsugamushi (OT-WCA was prepared by heat inactivation of Karp-strain bacteria. Rhesus macaques were infected intradermally with O. tsutsugamushi. Freshly isolated peripheral blood mononuclear cells (PBMC from infected (n = 10 and uninfected animals (n = 5 were stimulated with OT-WCA, and IFN-γ secreting cells quantitated by ELISpot assay at five time points over 28 days. PBMC were then assayed from people in a scrub typhus-endemic region of Thailand (n = 105 and responses compared to those from a partially exposed population in a non-endemic region (n = 14, and to a naïve population in UK (n = 12. Mean results at Day 0 prior to O. tsutsugamushi infection were 12 (95% CI 0-25 and 15 (2-27 spot-forming cells (SFC/106 PBMC for infected and control macaques respectively. Strong O. tsutsugamushi-specific IFN-γ responses were seen post infection, with ELISpot responses 20-fold higher than baseline at Day 7 (mean 235, 95% CI 200-270 SFC/106 PBMC, 105-fold higher at Day 14 (mean 1261, 95% CI 1,097-1,425 SFC/106 PBMC, 125-fold higher at Day 21 (mean 1,498, 95% CI 1,496-1,500 SFC/106 PBMC and 118-fold higher at

  13. Strong interferon-gamma mediated cellular immunity to scrub typhus demonstrated using a novel whole cell antigen ELISpot assay in rhesus macaques and humans.

    Science.gov (United States)

    Sumonwiriya, Manutsanun; Paris, Daniel H; Sunyakumthorn, Piyanate; Anantatat, Tippawan; Jenjaroen, Kemajittra; Chumseng, Suchintana; Im-Erbsin, Rawiwan; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Blacksell, Stuart D; Chowdhury, Fazle R; Kronsteiner, Barbara; Teparrukkul, Prapit; Burke, Robin L; Lombardini, Eric D; Richards, Allen L; Mason, Carl J; Jones, James W; Day, Nicholas P J; Dunachie, Susanna J

    2017-09-01

    Scrub typhus is a febrile infection caused by the obligate intracellular bacterium Orientia tsutsugamushi, which causes significant morbidity and mortality across the Asia-Pacific region. The control of this vector-borne disease is challenging due to humans being dead-end hosts, vertical maintenance of the pathogen in the vector itself, and a potentially large rodent reservoir of unclear significance, coupled with a lack of accurate diagnostic tests. Development of an effective vaccine is highly desirable. This however requires better characterization of the natural immune response of this neglected but important disease. Here we implement a novel IFN-γ ELISpot assay as a tool for studying O. tsutsugamushi induced cellular immune responses in an experimental scrub typhus rhesus macaque model and human populations. Whole cell antigen for O. tsutsugamushi (OT-WCA) was prepared by heat inactivation of Karp-strain bacteria. Rhesus macaques were infected intradermally with O. tsutsugamushi. Freshly isolated peripheral blood mononuclear cells (PBMC) from infected (n = 10) and uninfected animals (n = 5) were stimulated with OT-WCA, and IFN-γ secreting cells quantitated by ELISpot assay at five time points over 28 days. PBMC were then assayed from people in a scrub typhus-endemic region of Thailand (n = 105) and responses compared to those from a partially exposed population in a non-endemic region (n = 14), and to a naïve population in UK (n = 12). Mean results at Day 0 prior to O. tsutsugamushi infection were 12 (95% CI 0-25) and 15 (2-27) spot-forming cells (SFC)/106 PBMC for infected and control macaques respectively. Strong O. tsutsugamushi-specific IFN-γ responses were seen post infection, with ELISpot responses 20-fold higher than baseline at Day 7 (mean 235, 95% CI 200-270 SFC/106 PBMC), 105-fold higher at Day 14 (mean 1261, 95% CI 1,097-1,425 SFC/106 PBMC), 125-fold higher at Day 21 (mean 1,498, 95% CI 1,496-1,500 SFC/106 PBMC) and 118-fold higher at Day 28

  14. Measurement of dabigatran: previously demonstrated Hemoclot® Thrombin Inhibitor assay reagent instability on Sysmex CS-2100i is no longer an issue

    DEFF Research Database (Denmark)

    Comuth, Willemijn; Faaborg, Louise; Henriksen, Linda Østervig

    2017-01-01

    hours. Since the reagent composition was unchanged, the increased stability could be due to changed logistics by the supplier, with stock and transfer closer by. Previously demonstrated HTI reagent instability is no longer an issue at our laboratory. The reliability of results of clinical studies...

  15. Sequential chromatin immunoprecipitation to detect SUMOylated MeCP2 in neurons

    Directory of Open Access Journals (Sweden)

    Tao Wu

    2016-03-01

    Full Text Available The small ubiquitin-like modifier (SUMO is a short peptide that can be covalently linked to proteins altering their function. SUMOylation is an essential post-translational modification (PTM. Because of its dynamic nature, low abundance levels, and technical limitations, the occupation of endogenous SUMOylated transcription factors at genomic loci is challenging to detect. The chromatin regulator Methyl CpG binding protein 2 (MeCP2 is subjected to PTMs including SUMO. Mutations in MeCP2 lead to Rett syndrome, a severe neurodevelopmental disorder. Here, we present an efficient method to perform sequential chromatin immunoprecipitation (Seq-ChIP for detecting SUMOylated MeCP2 in neurons. This Seq-ChIP technique is a useful tool to determine the occupancy of SUMOylated transcription and chromatin factors at specific genomic regions.

  16. Identification of potential target genes for the tomato fruit-ripening regulator RIN by chromatin immunoprecipitation

    Directory of Open Access Journals (Sweden)

    Nakano Toshitsugu

    2011-01-01

    Full Text Available Abstract Background During ripening, climacteric fruits increase their ethylene level and subsequently undergo various physiological changes, such as softening, pigmentation and development of aroma and flavor. These changes occur simultaneously and are caused by the highly synchronized expression of numerous genes at the onset of ripening. In tomatoes, the MADS-box transcription factor RIN has been regarded as a key regulator responsible for the onset of ripening by acting upstream of both ethylene- and non-ethylene-mediated controls. However, except for LeACS2, direct targets of RIN have not been clarified, and little is known about the transcriptional cascade for ripening. Results Using immunoprecipitated (IPed DNA fragments recovered by chromatin immunoprecipitation (ChIP with anti-RIN antibody from ripening tomato fruit, we analyzed potential binding sites for RIN (CArG-box sites in the promoters of representative ripening-induced genes by quantitative PCR. Results revealed nearly a 5- to 20-fold enrichment of CArG boxes in the promoters of LeACS2, LeACS4, PG, TBG4, LeEXP1, and LeMAN4 and of RIN itself, indicating direct interaction of RIN with their promoters in vivo. Moreover, sequence analysis and genome mapping of 51 cloned IPed DNAs revealed potential RIN binding sites. Quantitative PCR revealed that four of the potential binding sites were enriched 4- to 17-fold in the IPed DNA pools compared with the controls, indicating direct interaction of RIN with these sites in vivo. Near one of the four CArG boxes we found a gene encoding a protein similar to thioredoxin y1. An increase in the transcript level of this gene was observed with ripening in normal fruit but not in the rin mutant, suggesting that RIN possibly induces its expression. Conclusions The presented results suggest that RIN controls fruit softening and ethylene production by the direct transcriptional regulation of cell-wall-modifying genes and ethylene biosynthesis genes

  17. Identification of potential target genes for the tomato fruit-ripening regulator RIN by chromatin immunoprecipitation.

    Science.gov (United States)

    Fujisawa, Masaki; Nakano, Toshitsugu; Ito, Yasuhiro

    2011-01-30

    During ripening, climacteric fruits increase their ethylene level and subsequently undergo various physiological changes, such as softening, pigmentation and development of aroma and flavor. These changes occur simultaneously and are caused by the highly synchronized expression of numerous genes at the onset of ripening. In tomatoes, the MADS-box transcription factor RIN has been regarded as a key regulator responsible for the onset of ripening by acting upstream of both ethylene- and non-ethylene-mediated controls. However, except for LeACS2, direct targets of RIN have not been clarified, and little is known about the transcriptional cascade for ripening. Using immunoprecipitated (IPed) DNA fragments recovered by chromatin immunoprecipitation (ChIP) with anti-RIN antibody from ripening tomato fruit, we analyzed potential binding sites for RIN (CArG-box sites) in the promoters of representative ripening-induced genes by quantitative PCR. Results revealed nearly a 5- to 20-fold enrichment of CArG boxes in the promoters of LeACS2, LeACS4, PG, TBG4, LeEXP1, and LeMAN4 and of RIN itself, indicating direct interaction of RIN with their promoters in vivo. Moreover, sequence analysis and genome mapping of 51 cloned IPed DNAs revealed potential RIN binding sites. Quantitative PCR revealed that four of the potential binding sites were enriched 4- to 17-fold in the IPed DNA pools compared with the controls, indicating direct interaction of RIN with these sites in vivo. Near one of the four CArG boxes we found a gene encoding a protein similar to thioredoxin y1. An increase in the transcript level of this gene was observed with ripening in normal fruit but not in the rin mutant, suggesting that RIN possibly induces its expression. The presented results suggest that RIN controls fruit softening and ethylene production by the direct transcriptional regulation of cell-wall-modifying genes and ethylene biosynthesis genes during ripening. Moreover, the binding of RIN to its own

  18. Chromatin immunoprecipitation improvements for the processing of small frozen pieces of adipose tissue.

    Directory of Open Access Journals (Sweden)

    Daniel Castellano-Castillo

    Full Text Available Chromatin immunoprecipitation (ChIP has gained importance to identify links between the genome and the proteome. Adipose tissue has emerged as an active tissue, which secretes a wide range of molecules that have been related to metabolic and obesity-related disorders, such as diabetes, cardiovascular failure, metabolic syndrome, or cancer. In turn, epigenetics has raised the importance in discerning the possible relationship between metabolic disorders, lifestyle and environment. However, ChIP application in human adipose tissue is limited by several factors, such as sample size, frozen sample availability, high lipid content and cellular composition of the tissue. Here, we optimize the standard protocol of ChIP for small pieces of frozen human adipose tissue. In addition, we test ChIP for the histone mark H3K4m3, which is related to active promoters, and validate the performance of the ChIP by analyzing gene promoters for factors usually studied in adipose tissue using qPCR. Our improvements result in a higher performance in chromatin shearing and DNA recovery of adipocytes from the tissue, which may be useful for ChIP-qPCR or ChIP-seq analysis.

  19. Red cell autoantibodies characterized by competitive inhibition of iodine 125 Rh alloantibody binding and by immunoprecipitation of membrane proteins

    International Nuclear Information System (INIS)

    Pierce, S.W.; Victoria, E.J.; Masouredis, S.P.

    1990-01-01

    The relationship between determinants recognized by warm-type immunoglobulin G red cell autoantibodies and the Rh antigens was characterized by autoantibody competitive inhibition of iodine 125 Rh alloantibody binding and autoantibody immunoprecipitation of iodine 125 red blood cell membrane proteins. The majority of blood donor autoantibody recognized epitopes that are closely related to Rh antigens as determined by competitive inhibition studies. Eighteen of 20 (90%) autoantibodies inhibited anti-Rh(c) binding, 15 inhibited anti-Rh(E), 5 inhibited anti-Rh(D), and only 2 failed to inhibit any of the three Rh alloantibodies tested. Autoantibodies that inhibited anti-Rh(D) also inhibited anti-Rh(c) and anti-Rh(E) and all those that inhibited anti-Rh(E) also inhibited anti-Rh(c). Autoantibodies that inhibited all three Rh alloantibodies immunoprecipitated 30 kd membrane polypeptides, as did two of the three autoantibodies that inhibited only anti-Rh(c) and anti-Rh(E). One autoantibody in this group and two autoantibodies that inhibited only anti-Rh(c), as well as an autoantibody that did not inhibit any of the Rh alloantibodies, immunoprecipitated only a single membrane polypeptide identified as band 3. The majority of normal donor red blood cell autoantibodies inhibited the binding of Rh alloantibodies, which indicates that they either bound to the Rh polypeptides or to epitopes on band 3 that were closely associated with the Rh complex

  20. Chromatin Immunoprecipitation (ChIP): Revisiting the Efficacy of Sample Preparation, Sonication, Quantification of Sheared DNA, and Analysis via PCR

    Science.gov (United States)

    Schoppee Bortz, Pamela D.; Wamhoff, Brian R.

    2011-01-01

    The “quantitative” ChIP, a tool commonly used to study protein-DNA interactions in cells and tissue, is a difficult assay often plagued with technical error. We present, herein, the process required to merge multiple protocols into a quick, reliable and easy method and an approach to accurately quantify ChIP DNA prior to performing PCR. We demonstrate that high intensity sonication for at least 30 min is required for full cellular disruption and maximum DNA recovery because ChIP lysis buffers fail to lyse formaldehyde-fixed cells. In addition, extracting ChIP DNA with chelex-100 yields samples that are too dilute for evaluation of shearing efficiency or quantification via nanospectrophotometry. However, DNA extracted from the Mock-ChIP supernatant via the phenol-chloroform-isoamyl alcohol (PCIA) method can be used to evaluate DNA shearing efficiency and used as the standard in a fluorescence-based microplate assay. This enabled accurate quantification of DNA in chelex-extracted ChIP samples and normalization to total DNA concentration prior to performing real-time PCR (rtPCR). Thus, a quick ChIP assay that can be completed in nine bench hours over two days has been validated along with a rapid, accurate and repeatable way to quantify ChIP DNA. The resulting rtPCR data more accurately depicts treatment effects on protein-DNA interactions of interest. PMID:22046253

  1. Using Chromatin Immunoprecipitation in Toxicology: A Step-by-Step Guide to Increasing Efficiency, Reducing Variability, and Expanding Applications.

    Science.gov (United States)

    McCullough, Shaun D; On, Doan M; Bowers, Emma C

    2017-05-02

    Histone modifications work in concert with DNA methylation to regulate cellular structure, function, and response to environmental stimuli. More than 130 unique histone modifications have been described to date, and chromatin immunoprecipitation (ChIP) allows for the exploration of their associations with the regulatory regions of target genes and other DNA/chromatin-associated proteins across the genome. Many variations of ChIP have been developed in the 30 years since its earliest version came into use, which makes it challenging for users to integrate the procedure into their research programs. Furthermore, the differences in ChIP protocols can confound efforts to increase reproducibility across studies. The streamlined ChIP procedure presented here can be readily applied to samples from a wide range of in vitro studies (cell lines and primary cells) and clinical samples (peripheral leukocytes) in toxicology. We also provide detailed guidance on the optimization of critical protocol parameters, such as chromatin fixation, fragmentation, and immunoprecipitation, to increase efficiency and improve reproducibility. Expanding toxicoepigenetic studies to more readily include histone modifications will facilitate a more comprehensive understanding of the role of the epigenome in environmental exposure effects and the integration of epigenetic data in mechanistic toxicology, adverse outcome pathways, and risk assessment. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  2. Single Doses up to 800 mg of E-52862 Do Not Prolong the QTc Interval--A Retrospective Validation by Pharmacokinetic-Pharmacodynamic Modelling of Electrocardiography Data Utilising the Effects of a Meal on QTc to Demonstrate ECG Assay Sensitivity.

    Science.gov (United States)

    Täubel, Jörg; Ferber, Georg; Lorch, Ulrike; Wang, Duolao; Sust, Mariano; Camm, A John

    2015-01-01

    E-52862 is a Sigma-1 receptor antagonist (S1RA) currently under investigation as a potential analgesic medicine. We successfully applied a concentration-effect model retrospectively to a four-way crossover Phase I single ascending dose study and utilized the QTc shortening effects of a meal to demonstrate assay sensitivity by establishing the time course effects from baseline in all four periods, independently from any potential drug effects. Thirty two healthy male and female subjects were included in four treatment periods to receive single ascending doses of 500 mg, 600 mg or 800 mg of E-52862 or placebo. PK was linear over the dose range investigated and doses up to 600 mg were well tolerated. The baseline electrocardiography (ECG) measurements on Day-1 were time-matched with ECG and pharmacokinetic (PK) samples on Day 1 (dosing day). In this conventional mean change to time-matched placebo analysis, the largest time-matched difference to placebo QTcI was 1.44 ms (90% CI: -4.04, 6.93 ms) for 500 mg; -0.39 ms (90% CI: -3.91, 3.13 ms) for 600 mg and 1.32 ms (90% CI: -1.89, 4.53 ms) for 800 mg of E-52862, thereby showing the absence of any QTc prolonging effect at the doses tested. In addition concentration-effect models, one based on the placebo corrected change from baseline and one for the change of QTcI from average baseline with time as fixed effect were fitted to the data confirming the results of the time course analysis. The sensitivity of this study to detect small changes in the QTc interval was confirmed by demonstrating a shortening of QTcF of -8.1 (90% CI: -10.4, -5.9) one hour and -7.2 (90% CI: -9.4, -5.0) three hours after a standardised meal. EU Clinical Trials Register EudraCT 2010 020343 13.

  3. Dramatic repositioning of c-Myb to different promoters during the cell cycle observed by combining cell sorting with chromatin immunoprecipitation.

    Directory of Open Access Journals (Sweden)

    Anita M Quintana

    2011-02-01

    Full Text Available The c-Myb transcription factor is a critical regulator of proliferation and stem cell differentiation, and mutated alleles of c-Myb are oncogenic, but little is known about changes in c-Myb activity during the cell cycle. To map the association of c-Myb with specific target genes during the cell cycle, we developed a novel Fix-Sort-ChIP approach, in which asynchronously growing cells were fixed with formaldehyde, stained with Hoechst 33342 and separated into different cell cycle fractions by flow sorting, then processed for chromatin immunoprecipitation (ChIP assays. We found that c-Myb actively repositions, binding to some genes only in specific cell cycle phases. In addition, the specificity of c-Myb is dramatically different in small subpopulations of cells, for example cells in the G2/M phase of the cell cycle, than in the bulk population. The repositioning of c-Myb during the cell cycle is not due to changes in its expression and also occurs with ectopically expressed, epitope-tagged versions of c-Myb. The repositioning occurs in established cell lines, in primary human CD34+ hematopoietic progenitors and in primary human acute myeloid leukemia cells. The combination of fixation, sorting and ChIP analysis sheds new light on the dynamic nature of gene regulation during the cell cycle and provides a new type of tool for the analysis of gene regulation in small subsets of cells, such as cells in a specific phase of the cell cycle.

  4. Luminescent Immunoprecipitation System (LIPS) for Detection of Autoantibodies Against ATP4A and ATP4B Subunits of Gastric Proton Pump H+,K+-ATPase in Atrophic Body Gastritis Patients

    Science.gov (United States)

    Lahner, Edith; Brigatti, Cristina; Marzinotto, Ilaria; Carabotti, Marilia; Scalese, Giulia; Davidson, Howard W; Wenzlau, Janet M; Bosi, Emanuele; Piemonti, Lorenzo; Annibale, Bruno; Lampasona, Vito

    2017-01-01

    Objectives: Circulating autoantibodies targeting the H+/K+-ATPase proton pump of gastric parietal cells are considered markers of autoimmune gastritis, whose diagnostic accuracy in atrophic body gastritis, the pathological lesion of autoimmune gastritis, remains unknown. This study aimed to assess autoantibodies against ATP4A and ATP4B subunits of parietal cells H+, K+-ATPase in atrophic body gastritis patients and controls. Methods: One-hundred and four cases with atrophic body gastritis and 205 controls were assessed for serological autoantibodies specific for ATP4A or ATP4B subunits using luminescent immunoprecipitation system (LIPS). Recombinant luciferase-reporter-fused-antigens were expressed by in vitro transcription-translation (ATP4A) or after transfection in Expi293F cells (ATP4B), incubated with test sera, and immune complexes recovered using protein-A-sepharose. LIPS assays were compared with a commercial enzyme immunoassay (EIA) for parietal cell autoantibodies. Results: ATP4A and ATP4B autoantibody titers were higher in cases compared to controls (Pgastritis. Both assays had the highest sensitivity, at the cost of diagnostic accuracy (89 and 90% specificity), outperforming traditional EIA. Once validated, these LIPS assays should be valuable screening tools for detecting biomarkers of damaged atrophic oxyntic mucosa. PMID:28102858

  5. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  6. Assay system

    International Nuclear Information System (INIS)

    Patzke, J.B.; Rosenberg, B.J.

    1984-01-01

    The accuracy of assays for monitoring concentrations of basic drugs in biological fluids containing a 1 -acid glycoproteins, such as blood (serum or plasma), is improved by the addition of certain organic phosphate compounds to minimize the ''protein effect.'' Kits containing the elements of the invention are also disclosed

  7. Experimental Design and Methods for Development of Diagnostic Assays for Schistosomiasis Using Monoclonal Antibodies.

    Science.gov (United States)

    1983-08-25

    solium, Echinococcus granulosus , Entamoeba histolytica, or Wucher erTra-bancr--ofti. The S. mansoni glycoproteins that were immunoprecipitated by sera...Sera from patients or experimental animals infected with Schistosoma, Fasciola hepatica, Trichinella spiralis, Taenia solium, Echinococcus ... granulosus , or Paragonimus westermani cross-react in diag-nostic assays with antigens derived from schistosomes, whether as whole organisms (1-4), crude

  8. Optimal use of tandem biotin and V5 tags in ChIP assays

    NARCIS (Netherlands)

    K.E. Kolodziej (Katarzyna); F. Pourfarzad, F. (Farzin); E. de Boer (Ernie); S. Krpic (Sanja); F.G. Grosveld (Frank); J. Strouboulis (John)

    2009-01-01

    textabstractBackground: Chromatin immunoprecipitation (ChIP) assays coupled to genome arrays (Chip-on-chip) or massive parallel sequencing (ChIP-seq) lead to the genome wide identification of binding sites of chromatin associated proteins. However, the highly variable quality of antibodies and the

  9. Encapsulation of adenovirus serotype 5 in anionic lecithin liposomes using a bead-based immunoprecipitation technique enhances transfection efficiency.

    Science.gov (United States)

    Mendez, Natalie; Herrera, Vanessa; Zhang, Lingzhi; Hedjran, Farah; Feuer, Ralph; Blair, Sarah L; Trogler, William C; Reid, Tony R; Kummel, Andrew C

    2014-11-01

    Oncolytic viruses (OVs) constitute a promising class of cancer therapeutics which exploit validated genetic pathways known to be deregulated in many cancers. To overcome an immune response and to enhance its potential use to treat primary and metastatic tumors, a method for liposomal encapsulation of adenovirus has been developed. The encapsulation of adenovirus in non-toxic anionic lecithin-cholesterol-PEG liposomes ranging from 140 to 180 nm in diameter have been prepared by self-assembly around the viral capsid. The encapsulated viruses retain their ability to infect cancer cells. Furthermore, an immunoprecipitation (IP) technique has shown to be a fast and effective method to extract non-encapsulated viruses and homogenize the liposomes remaining in solution. 78% of adenovirus plaque forming units were encapsulated and retained infectivity after IP processing. Additionally, encapsulated viruses have shown enhanced transfection efficiency up to 4 × higher compared to non-encapsulated Ads. Extracting non-encapsulated viruses from solution may prevent an adverse in vivo immune response and may enhance treatment for multiple administrations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Encapsulation of Adenovirus Serotype 5 in Anionic Lecithin Liposomes using a Bead-Based Immunoprecipitation Technique Enhances Transfection Efficiency

    Science.gov (United States)

    Mendez, N.; Herrera, V.; Zhang, L.; Hedjran, F.; Feuer, R.; Blair, S.; Trogler, W.; Reid, T.

    2014-01-01

    Oncolytic viruses (OVs) constitute a promising class of cancer therapeutics which exploit validated genetic pathways known to be deregulated in many cancers. To overcome an immune response and to enhance its potential use to treat primary and metastatic tumors, a method for liposomal encapsulation of adenovirus has been developed. The encapsulation of adenovirus in non-toxic anionic lecithin-cholesterol-PEG liposomes ranging from 140–180nm in diameter have been prepared by self-assembly around the viral capsid. The encapsulated viruses retain their ability to infect cancer cells. Furthermore, an immunoprecipitation (IP) technique has shown to be a fast and effective method to extract non-encapsulated viruses and homogenize the liposomes remaining in solution. 78% of adenovirus plaque forming units were encapsulated and retained infectivity after IP processing. Additionally, encapsulated viruses have shown enhanced transfection efficiency up to 4× higher compared to non-encapsulated Ads. Extracting non-encapsulated viruses from solution may prevent an adverse in vivo immune response and may enhance treatment for multiple administrations. PMID:25154663

  11. Effective Identification of Akt Interacting Proteins by Two-Step Chemical Crosslinking, Co-Immunoprecipitation and Mass Spectrometry

    Science.gov (United States)

    Huang, Bill X.; Kim, Hee-Yong

    2013-01-01

    Akt is a critical protein for cell survival and known to interact with various proteins. However, Akt binding partners that modulate or regulate Akt activation have not been fully elucidated. Identification of Akt-interacting proteins has been customarily achieved by co-immunoprecipitation combined with western blot and/or MS analysis. An intrinsic problem of the method is loss of interacting proteins during procedures to remove non-specific proteins. Moreover, antibody contamination often interferes with the detection of less abundant proteins. Here, we developed a novel two-step chemical crosslinking strategy to overcome these problems which resulted in a dramatic improvement in identifying Akt interacting partners. Akt antibody was first immobilized on protein A/G beads using disuccinimidyl suberate and allowed to bind to cellular Akt along with its interacting proteins. Subsequently, dithiobis[succinimidylpropionate], a cleavable crosslinker, was introduced to produce stable complexes between Akt and binding partners prior to the SDS-PAGE and nanoLC-MS/MS analysis. This approach enabled identification of ten Akt partners from cell lysates containing as low as 1.5 mg proteins, including two new potential Akt interacting partners. None of these but one protein was detectable without crosslinking procedures. The present method provides a sensitive and effective tool to probe Akt-interacting proteins. This strategy should also prove useful for other protein interactions, particularly those involving less abundant or weakly associating partners. PMID:23613850

  12. Chromatin immunoprecipitation (ChIP) of plant transcription factors followed by sequencing (ChIP-SEQ) or hybridization to whole genome arrays (ChIP-CHIP)

    NARCIS (Netherlands)

    Kaufmann, K.; Muiño, J.M.; Østerås, M.; Farinelli, L.; Krajewski, P.; Angenent, G.C.

    2010-01-01

    Chromatin immunoprecipitation (ChIP) is a powerful technique to study interactions between transcription factors (TFs) and DNA in vivo. For genome-wide de novo discovery of TF-binding sites, the DNA that is obtained in ChIP experiments needs to be processed for sequence identification. The sequences

  13. Measurement of O-GlcNAcylated endothelial nitric oxide synthase by using 2',5'-ADP-Sepharose pull-down assay.

    Science.gov (United States)

    Long, Yang; Yan, Jianghong; Luo, Suxin; Liu, Zhenguo; Xia, Yong

    2017-11-15

    Endothelial nitric oxide synthase (eNOS) plays central roles in cardiovascular regulation and disease. eNOS function is critically affected by O-linked N-acetylglucosamine (O-GlcNAc) modification. The present method for measuring O-GlcNAcylated eNOS relies on immunoprecipitation. Such method exhibits low detection efficiency and is also costly. We here report a simplified assay by employing the high binding affinity of eNOS with the 2',5'-ADP-Sepharose resins. Together with the O-GlcNAc antibody, this assay readily allows the detection of O-GlcNAcylated eNOS in both cultured endothelial cells and rat vascular tissues. By using this assay, we demonstrate that eNOS O-GlcNAcylation is markedly elevated in the vessels of diabetic rats. Thus, a 2',5'-ADP-Sepharose-based pull-down assay is developed to measure O-GlcNAcylated eNOS. This assay is simple and efficient in detecting O-GlcNAcylated eNOS in cultured cells and animal tissues under both normal and disease conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Immunoassays in clinical chemistry (principles of immunoradiometric assays)

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    The use of antibodies as reagents in clinical chemistry for the quantitation of a wide range of analytes has now become widely established. Initially antibodies were employed in precipitation techniques, usually for the analysis of serum proteins, in solution or in the form of antibody containing gels, e.g. immunoprecipitation, immunodiffusion, and immunoelectrophoresis. Further developments have led to the highly sensitive techniques of radioimmunoassay and recently immunometric assay for the measurement of drugs, tumour markers and hormones. In general, those techniques without the addition of a label e.g. immunoprecipitation, immunodiffusion and immunoturbidimetry are the older techniques used for the measurement of serum proteins. These techniques are relatively insensitive, measuring at the g/L. level, and in the case of immunodiffusion are generally slow. Automation coupled with the development of chemistries to enhance precipitation has, however, reduced measurement times to minutes in modern laboratories. Nevertheless these methods have detection limits of the order of 1 g/L

  15. Comparison of In-Vitro and Ex-Vivo Wound Healing Assays for the Investigation of Diabetic Wound Healing and Demonstration of a Beneficial Effect of a Triterpene Extract.

    Directory of Open Access Journals (Sweden)

    Christopher Ueck

    Full Text Available Diabetes mellitus is a frequent cause for chronic, difficult-to-treat wounds. New therapies for diabetic wounds are urgently needed and in-vitro or ex-vivo test systems are essential for the initial identification of new active molecules. The aim of this study is to compare in-vitro and ex-vivo test systems for their usability for early drug screening and to investigate the efficacy of a birch bark triterpene extract (TE that has been proven ex-vivo and clinically to accelerate non-diabetic wound healing (WH, in a diabetic context. We investigated in-vitro models for diabetic WH, i.e. scratch assays with human keratinocytes from diabetic donors or cultured under hyperglycaemic conditions and a newly developed porcine ex-vivo hyperglycaemic WH model for their potential to mimic delayed diabetic WH and for the influence of TE in these test systems. We show that keratinocytes from diabetic donors often fail to exhibit significantly delayed WH. For cells under hyperglycaemic conditions significant decrease is observed but is influenced by choice of medium and presence of supplements. Also, donor age plays a role. Interestingly, hyperglycaemic effects are mainly hyperosmolaric effects in scratch assays. Ex-vivo models under hyperglycaemic conditions show a clear and substantial decrease of WH, and here both glucose and hyperosmolarity effects are involved. Finally, we provide evidence that TE is also beneficial for ex-vivo hyperglycaemic WH, resulting in significantly increased length of regenerated epidermis to 188±16% and 183±11% (SEM; p<0.05 compared to controls when using two different TE formulations. In conclusion, our results suggest that microenvironmental influences are important in WH test systems and that therefore the more complex hyperglycaemic ex-vivo model is more suitable for early drug screening. Limitations of the in-vitro and ex-vivo models are discussed. Furthermore our data recommend TE as a promising candidate for in

  16. Tested Demonstrations.

    Science.gov (United States)

    Gilbert, George L.

    1983-01-01

    An apparatus is described in which effects of pressure, volume, and temperature changes on a gas can be observed simultaneously. Includes use of the apparatus in demonstrating Boyle's, Gay-Lussac's, and Charles' Laws, attractive forces, Dalton's Law of Partial pressures, and in illustrating measurable vapor pressures of liquids and some solids.…

  17. Tested Demonstrations.

    Science.gov (United States)

    Gilbert, George L., Ed.

    1987-01-01

    Describes two demonstrations to illustrate characteristics of substances. Outlines a method to detect the changes in pH levels during the electrolysis of water. Uses water pistols, one filled with methane gas and the other filled with water, to illustrate the differences in these two substances. (TW)

  18. Two different protein expression profiles of oral squamous cell carcinoma analyzed by immunoprecipitation high-performance liquid chromatography.

    Science.gov (United States)

    Kim, Soung Min; Jeong, Dasul; Kim, Min Keun; Lee, Sang Shin; Lee, Suk Keun

    2017-08-08

    Oral squamous cell carcinoma (OSCC) is one of the most dangerous cancers in the body, producing serious complications with individual behaviors. Many different pathogenetic factors are involved in the carcinogenesis of OSCC. Cancer cells derived from oral keratinocytes can produce different carcinogenic signaling pathways through differences in protein expression, but their protein expression profiles cannot be easily explored with ordinary detection methods. The present study compared the protein expression profiles between two different types of OSCCs, which were analyzed through immunoprecipitation high-performance liquid chromatography (IP-HPLC). Two types of squamous cell carcinoma (SCC) occurred in a mandibular (SCC-1) and maxillary gingiva (SCC-2), but their clinical features and progression were quite different from each other. SCC-1 showed a large gingival ulceration with severe halitosis and extensive bony destruction, while SCC-2 showed a relatively small papillary gingival swelling but rapidly grew to form a large submucosal mass, followed by early cervical lymph node metastasis. In the histological observation, SCC-1 was relatively well differentiated with a severe inflammatory reaction, while SCC-2 showed severely infiltrative growth of each cancer islets accompanied with a mild inflammatory reaction. IP-HPLC analysis revealed contrary protein expression profiles analyzed by 72 different oncogenic proteins. SCC-1 showed more cellular apoptosis and invasive growth than SCC-2 through increased expression of caspases, MMPs, p53 signaling, FAS signaling, TGF-β1 signaling, and angiogenesis factors, while SCC-2 showed more cellular growth and survival than SCC-1 through the increased expression of proliferating factors, RAS signaling, eIF5A signaling, WNT signaling, and survivin. The increased trends of cellular apoptosis and invasiveness in the protein expression profiles of SCC-1 were implicative of its extensive gingival ulceration and bony destruction

  19. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  20. A survey of 17α-ethinylestradiol and mestranol residues in Hawkesbury River, Australia, using a highly specific enzyme-linked immunosorbent assay (ELISA) demonstrates the levels of potential biological significance.

    Science.gov (United States)

    Uraipong, Chatchaporn; Allan, Robin D; Li, Chunhua; Kennedy, Ivan R; Wong, Victor; Lee, Nanju Alice

    2017-10-01

    This study reports on the potential status of 17α-ethinylestradiol (EE2) and mestranol (MeEE2) residues in aquatic environments in New South Wales (NSW), Australia, based on the analysis by a specific ELISA we developed. Polyclonal antibodies were raised against the EE2 hapten with a linker attached at the C3-position to direct the antibody binding towards the ring D of EE2/MeEE2. Using this approach, an ELISA highly specific to EE2 and MeEE2 was successfully developed, showing less than 3.1% cross-reactivity (% CR) with other major steroidal sex hormones and their derivatives. The assay performed with the limit of detection (LOD) of 0.04 ± 0.01µg/L for both EE2 and MeEE2, and the limit of quantitation (LOQ) of 0.05 ± 0.01ng/L when it was coupled with the SM2-Biobeads solid phase extraction. Prior to conducting the survey study, it was validated against the gas chromatography-mass spectrophotometry (GC-MS) method, which showed high correlation with R 2 of 0.934. Fresh surface water samples collected at different sites along Hawkesbury River in New South Wales (NSW) were analyzed for the EE2/ MeEE2 residues using the developed ELISA. The EE2/MeEE2 levels were found to range between 4.1 and 8.3ng/L in Emigrant Creek, NSW, where the primary activity was macadamia plantation, and higher levels between 15 and 29ng/L in South Creek, NSW, Greater Western Sydney at sites upstream and downstream of the municipal sewage treatment plants. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. [Immunoprecipitation mapping of the TRX-associated chromosome elements in the fork head gene promoter in the Drosophila melanogaster salivary gland cells].

    Science.gov (United States)

    Riakhovskiĭ, A A; Tillib, S V

    2007-09-01

    Using the method of immunoprecipitation of the in vivo crosslinked and sheared by sonication chromatin, mapping of potential trithorax-associated regulatory elements within the extended (9 kb) promoter region of the fork head gene (fkh) in the Drosophila melanogaster salivary gland cells was performed. Relative homogeneity of the salivary gland cells, along with the parallel use of the antibodies to different domains of the same trithorax protein (TRX), and the introduction of cross-hybridization steps for additional specific enrichment of initial DNA libraries, provided improvement of the method effectiveness and identification of one major and two less expressed potential TRX-binding sites.

  2. A new scintillation proximity assay-based approach for the detection of KRAS mutations

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So-Young; Lim, Jae-Cheong; Cho, Eun-Ha; Jung, Sung-Hee [Korea Atomic Energy Research Institute (KAERI), Daejeon (Korea, Republic of). Radioisotope Research Div.

    2016-04-01

    KRAS is very commonly mutated resulting in a constitutively activated protein, which is independent of epidermal growth factor receptor (EGFR) ligand binding and resistant to anti-EGFR therapy. Although KRAS is frequently studied, there is still no uniform standard for detecting of KRAS mutations. In this report, a new scintillation proximity assay-based approach is described that determines the relative affinities of wild-type and mutated KRAS to the anti-KRAS antibody. We performed in vitro experiments using normal human colonic cells (CCD18Co), KRAS wild type (Caco-2) and KRAS mutant (HCT 116) cell lines to determine the relative affinities of wild type or mutated KRAS toward an anti-KRAS monoclonal antibody. The process consists of two primary steps: immunoprecipitation from cell lysate to enrich the KRAS protein and the scintillation proximity assay of the immunoprecipitant to determine the relative affinity against the antibody. A fixed concentration of cell lysates was purified by the immunoprecipitation method. The expressions of the KRAS protein in all cell lines was quantitatively confirmed by western blot analysis. For the scintillation proximity assay, the KRAS standard protein was radiolabeled with {sup 125}I by a simple mixing process in the iodogen tube immediately at room temperature immediately before use. The obtained CPM (count per minute) values of were used to calculate the KRAS concentration using purified KRAS as the standard. The calculated relative affinities of 7 μg of Caco-2 and HCT 116 immunoprecipitants for the anti-KRAS antibody were 77 and 0%, respectively. The newly developed scintillation proximity assay-based strategy determines the relative affinities of wild-type or mutated KRAS towards the anti-KRAS monoclonal antibody. This determination can help distinguish mutated KRAS from the wild type protein. The new SPA based approach for detecting KRAS mutations is applicable to many other cancer-related mutations.

  3. A new scintillation proximity assay-based approach for the detection of KRAS mutations

    International Nuclear Information System (INIS)

    Lee, So-Young; Lim, Jae-Cheong; Cho, Eun-Ha; Jung, Sung-Hee

    2016-01-01

    KRAS is very commonly mutated resulting in a constitutively activated protein, which is independent of epidermal growth factor receptor (EGFR) ligand binding and resistant to anti-EGFR therapy. Although KRAS is frequently studied, there is still no uniform standard for detecting of KRAS mutations. In this report, a new scintillation proximity assay-based approach is described that determines the relative affinities of wild-type and mutated KRAS to the anti-KRAS antibody. We performed in vitro experiments using normal human colonic cells (CCD18Co), KRAS wild type (Caco-2) and KRAS mutant (HCT 116) cell lines to determine the relative affinities of wild type or mutated KRAS toward an anti-KRAS monoclonal antibody. The process consists of two primary steps: immunoprecipitation from cell lysate to enrich the KRAS protein and the scintillation proximity assay of the immunoprecipitant to determine the relative affinity against the antibody. A fixed concentration of cell lysates was purified by the immunoprecipitation method. The expressions of the KRAS protein in all cell lines was quantitatively confirmed by western blot analysis. For the scintillation proximity assay, the KRAS standard protein was radiolabeled with 125 I by a simple mixing process in the iodogen tube immediately at room temperature immediately before use. The obtained CPM (count per minute) values of were used to calculate the KRAS concentration using purified KRAS as the standard. The calculated relative affinities of 7 μg of Caco-2 and HCT 116 immunoprecipitants for the anti-KRAS antibody were 77 and 0%, respectively. The newly developed scintillation proximity assay-based strategy determines the relative affinities of wild-type or mutated KRAS towards the anti-KRAS monoclonal antibody. This determination can help distinguish mutated KRAS from the wild type protein. The new SPA based approach for detecting KRAS mutations is applicable to many other cancer-related mutations.

  4. A comparison of digital gene expression profiling and methyl DNA immunoprecipitation as methods for gene discovery in honeybee (Apis mellifera behavioural genomic analyses.

    Directory of Open Access Journals (Sweden)

    Cui Guan

    Full Text Available The honey bee has a well-organized system of division of labour among workers. Workers typically progress through a series of discrete behavioural castes as they age, and this has become an important case study for exploring how dynamic changes in gene expression can influence behaviour. Here we applied both digital gene expression analysis and methyl DNA immunoprecipitation analysis to nurse, forager and reverted nurse bees (nurses that have returned to the nursing state after a period spent foraging from the same colony in order to compare the outcomes of these different forms of genomic analysis. A total of 874 and 710 significantly differentially expressed genes were identified in forager/nurse and reverted nurse/forager comparisons respectively. Of these, 229 genes exhibited reversed directions of gene expression differences between the forager/nurse and reverted nurse/forager comparisons. Using methyl-DNA immunoprecipitation combined with high-throughput sequencing (MeDIP-seq we identified 366 and 442 significantly differentially methylated genes in forager/nurse and reverted nurse/forager comparisons respectively. Of these, 165 genes were identified as differentially methylated in both comparisons. However, very few genes were identified as both differentially expressed and differentially methylated in our comparisons of nurses and foragers. These findings confirm that changes in both gene expression and DNA methylation are involved in the nurse and forager behavioural castes, but the different analytical methods reveal quite distinct sets of candidate genes.

  5. An acoustic prion assay

    Directory of Open Access Journals (Sweden)

    Gordon Hayward

    2016-12-01

    Full Text Available An acoustic prion assay has been demonstrated for sheep brain samples. Only five false positives and no false negatives were observed in a test of 45 positive and 45 negative samples. The acoustic prion sensor was constructed using a thickness shear mode quartz resonator coated with a covalently bound recombinant prion protein. The characteristic indicator of a scrapie infected sheep brain sample was an observed shoulder in the frequency decrease in response to a sample.The response of the sensor aligns with a conformational shift in the surface protein and with the propagation mechanism of the disease. This alignment is evident in the response timing and shape, dependence on concentration, cross species behaviour and impact of blood plasma. This alignment is far from sufficient to prove the mechanism of the sensor but it does offer the possibility of a rapid and inexpensive additional tool to explore prion disease. Keywords: Prions, Thickness shear mode quartz sensor

  6. Identification of oxidised proteins in the matrix of rice leaf mitochondria by immunoprecipitation and two-dimensional liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Kristensen, B.K.; Askerlund, P.; Bykova, N.V.

    2004-01-01

    .2 mM CuSO4 for 10 min at room temperature). The oxidised proteins in both samples were tagged with dinitrophenylhydrazine (DNP), which forms a covalent bond with carbonyl groups. The DNP-tagged proteins were immunoprecipitated using anti-DNP antibodies and digested with trypsin. The mixture...... of peptides was analysed by nano-HPLC coupled online to an ESI-Quad-TOF mass spectrometer. The peptides were separated by stepwise ion exchange chromatography followed by reverse phase chromatography (2D-LC), and analysed by MS/MS. Proteins were identified by un-interpreted fragment ion database searches...... blots showed that neither the isolation of mitochondria, nor their subfractionation introduced carbonyl groups. We therefore conclude that a number of proteins are oxidised in the matrix of rice leaf mitochondria in vivo and further identify a group of proteins that are particularly susceptible to mild...

  7. Barcoded microchips for biomolecular assays.

    Science.gov (United States)

    Zhang, Yi; Sun, Jiashu; Zou, Yu; Chen, Wenwen; Zhang, Wei; Xi, Jianzhong Jeff; Jiang, Xingyu

    2015-01-20

    Multiplexed assay of analytes is of great importance for clinical diagnostics and other analytical applications. Barcode-based bioassays with the ability to encode and decode may realize this goal in a straightforward and consistent manner. We present here a microfluidic barcoded chip containing several sets of microchannels with different widths, imitating the commonly used barcode. A single barcoded microchip can carry out tens of individual protein/nucleic acid assays (encode) and immediately yield all assay results by a portable barcode reader or a smartphone (decode). The applicability of a barcoded microchip is demonstrated by human immunodeficiency virus (HIV) immunoassays for simultaneous detection of three targets (anti-gp41 antibody, anti-gp120 antibody, and anti-gp36 antibody) from six human serum samples. We can also determine seven pathogen-specific oligonucleotides by a single chip containing both positive and negative controls.

  8. Clinical validation of the Tempus xO assay

    Science.gov (United States)

    Beaubier, Nike; Tell, Robert; Huether, Robert; Bontrager, Martin; Bush, Stephen; Parsons, Jerod; Shah, Kaanan; Baker, Tim; Selkov, Gene; Taxter, Tim; Thomas, Amber; Bettis, Sam; Khan, Aly; Lau, Denise; Lee, Christina; Barber, Matthew; Cieslik, Marcin; Frankenberger, Casey; Franzen, Amy; Weiner, Ali; Palmer, Gary; Lonigro, Robert; Robinson, Dan; Wu, Yi-Mi; Cao, Xuhong; Lefkofsky, Eric; Chinnaiyan, Arul; White, Kevin P.

    2018-01-01

    We have developed a clinically validated NGS assay that includes tumor, germline and RNA sequencing. We apply this assay to clinical specimens and cell lines, and we demonstrate a clinical sensitivity of 98.4% and positive predictive value of 100% for the clinically actionable variants measured by the assay. We also demonstrate highly accurate copy number measurements and gene rearrangement identification. PMID:29899824

  9. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  10. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  11. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  12. Large-scale chromatin immunoprecipitation with promoter sequence microarray analysis of the interaction of the NSs protein of Rift Valley fever virus with regulatory DNA regions of the host genome.

    Science.gov (United States)

    Benferhat, Rima; Josse, Thibaut; Albaud, Benoit; Gentien, David; Mansuroglu, Zeyni; Marcato, Vasco; Souès, Sylvie; Le Bonniec, Bernard; Bouloy, Michèle; Bonnefoy, Eliette

    2012-10-01

    Rift Valley fever virus (RVFV) is a highly pathogenic Phlebovirus that infects humans and ruminants. Initially confined to Africa, RVFV has spread outside Africa and presently represents a high risk to other geographic regions. It is responsible for high fatality rates in sheep and cattle. In humans, RVFV can induce hepatitis, encephalitis, retinitis, or fatal hemorrhagic fever. The nonstructural NSs protein that is the major virulence factor is found in the nuclei of infected cells where it associates with cellular transcription factors and cofactors. In previous work, we have shown that NSs interacts with the promoter region of the beta interferon gene abnormally maintaining the promoter in a repressed state. In this work, we performed a genome-wide analysis of the interactions between NSs and the host genome using a genome-wide chromatin immunoprecipitation combined with promoter sequence microarray, the ChIP-on-chip technique. Several cellular promoter regions were identified as significantly interacting with NSs, and the establishment of NSs interactions with these regions was often found linked to deregulation of expression of the corresponding genes. Among annotated NSs-interacting genes were present not only genes regulating innate immunity and inflammation but also genes regulating cellular pathways that have not yet been identified as targeted by RVFV. Several of these pathways, such as cell adhesion, axonal guidance, development, and coagulation were closely related to RVFV-induced disorders. In particular, we show in this work that NSs targeted and modified the expression of genes coding for coagulation factors, demonstrating for the first time that this hemorrhagic virus impairs the host coagulation cascade at the transcriptional level.

  13. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  14. Nanobody®-based chromatin immunoprecipitation/micro-array analysis for genome-wide identification of transcription factor DNA binding sites

    Science.gov (United States)

    Nguyen-Duc, Trong; Peeters, Eveline; Muyldermans, Serge; Charlier, Daniel; Hassanzadeh-Ghassabeh, Gholamreza

    2013-01-01

    Nanobodies® are single-domain antibody fragments derived from camelid heavy-chain antibodies. Because of their small size, straightforward production in Escherichia coli, easy tailoring, high affinity, specificity, stability and solubility, nanobodies® have been exploited in various biotechnological applications. A major challenge in the post-genomics and post-proteomics era is the identification of regulatory networks involving nucleic acid–protein and protein–protein interactions. Here, we apply a nanobody® in chromatin immunoprecipitation followed by DNA microarray hybridization (ChIP-chip) for genome-wide identification of DNA–protein interactions. The Lrp-like regulator Ss-LrpB, arguably one of the best-studied specific transcription factors of the hyperthermophilic archaeon Sulfolobus solfataricus, was chosen for this proof-of-principle nanobody®-assisted ChIP. Three distinct Ss-LrpB-specific nanobodies®, each interacting with a different epitope, were generated for ChIP. Genome-wide ChIP-chip with one of these nanobodies® identified the well-established Ss-LrpB binding sites and revealed several unknown target sequences. Furthermore, these ChIP-chip profiles revealed auxiliary operator sites in the open reading frame of Ss-lrpB. Our work introduces nanobodies® as a novel class of affinity reagents for ChIP. Taking into account the unique characteristics of nanobodies®, in particular, their short generation time, nanobody®-based ChIP is expected to further streamline ChIP-chip and ChIP-Seq experiments, especially in organisms with no (or limited) possibility of genetic manipulation. PMID:23275538

  15. Detection of a rare BCR-ABL tyrosine kinase fusion protein in H929 multiple myeloma cells using immunoprecipitation (IP)-tandem mass spectrometry (MS/MS).

    Science.gov (United States)

    Breitkopf, Susanne B; Yuan, Min; Pihan, German A; Asara, John M

    2012-10-02

    Hypothesis directed proteomics offers higher throughput over global analyses. We show that immunoprecipitation (IP)-tandem mass spectrometry (LC-MS/MS) in H929 multiple myeloma (MM) cancer cells led to the discovery of a rare and unexpected BCR-ABL fusion, informing a therapeutic intervention using imatinib (Gleevec). BCR-ABL is the driving mutation in chronic myeloid leukemia (CML) and is uncommon to other cancers. Three different IP-MS experiments central to cell signaling pathways were sufficient to discover a BCR-ABL fusion in H929 cells: phosphotyrosine (pY) peptide IP, p85 regulatory subunit of phosphoinositide-3-kinase (PI3K) IP, and the GRB2 adaptor IP. The pY peptides inform tyrosine kinase activity, p85 IP informs the activating adaptors and receptor tyrosine kinases (RTKs) involved in AKT activation and GRB2 IP identifies RTKs and adaptors leading to ERK activation. Integration of the bait-prey data from the three separate experiments identified the BCR-ABL protein complex, which was confirmed by biochemistry, cytogenetic methods, and DNA sequencing revealed the e14a2 fusion transcript. The tyrosine phosphatase SHP2 and the GAB2 adaptor protein, important for MAPK signaling, were common to all three IP-MS experiments. The comparative treatment of tyrosine kinase inhibitor (TKI) drugs revealed only imatinib, the standard of care in CML, was inhibitory to BCR-ABL leading to down-regulation of pERK and pS6K and inhibiting cell proliferation. These data suggest a model for directed proteomics from patient tumor samples for selecting the appropriate TKI drug(s) based on IP and LC-MS/MS. The data also suggest that MM patients, in addition to CML patients, may benefit from BCR-ABL diagnostic screening.

  16. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  17. Factor IX assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003679.htm Factor IX assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  18. Factor VIII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003678.htm Factor VIII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  19. Factor II assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003674.htm Factor II assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  20. Factor VII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003676.htm Factor VII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  1. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  2. Functional analysis of neuronal microRNAs in Caenorhabditis elegans dauer formation by combinational genetics and Neuronal miRISC immunoprecipitation.

    Directory of Open Access Journals (Sweden)

    Minh T Than

    2013-06-01

    Full Text Available Identifying the physiological functions of microRNAs (miRNAs is often challenging because miRNAs commonly impact gene expression under specific physiological conditions through complex miRNA::mRNA interaction networks and in coordination with other means of gene regulation, such as transcriptional regulation and protein degradation. Such complexity creates difficulties in dissecting miRNA functions through traditional genetic methods using individual miRNA mutations. To investigate the physiological functions of miRNAs in neurons, we combined a genetic "enhancer" approach complemented by biochemical analysis of neuronal miRNA-induced silencing complexes (miRISCs in C. elegans. Total miRNA function can be compromised by mutating one of the two GW182 proteins (AIN-1, an important component of miRISC. We found that combining an ain-1 mutation with a mutation in unc-3, a neuronal transcription factor, resulted in an inappropriate entrance into the stress-induced, alternative larval stage known as dauer, indicating a role of miRNAs in preventing aberrant dauer formation. Analysis of this genetic interaction suggests that neuronal miRNAs perform such a role partly by regulating endogenous cyclic guanosine monophosphate (cGMP signaling, potentially influencing two other dauer-regulating pathways. Through tissue-specific immunoprecipitations of miRISC, we identified miRNAs and their likely target mRNAs within neuronal tissue. We verified the biological relevance of several of these miRNAs and found that many miRNAs likely regulate dauer formation through multiple dauer-related targets. Further analysis of target mRNAs suggests potential miRNA involvement in various neuronal processes, but the importance of these miRNA::mRNA interactions remains unclear. Finally, we found that neuronal genes may be more highly regulated by miRNAs than intestinal genes. Overall, our study identifies miRNAs and their targets, and a physiological function of these miRNAs in

  3. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  4. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  5. Rover waste assay system

    International Nuclear Information System (INIS)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J.

    1997-01-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235 U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137 Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  6. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  7. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  8. Assays for calcitonin receptors

    International Nuclear Information System (INIS)

    Teitelbaum, A.P.; Nissenson, R.A.; Arnaud, C.D.

    1985-01-01

    The assays for calcitonin receptors described focus on their use in the study of the well-established target organs for calcitonin, bone and kidney. The radioligand used in virtually all calcitonin binding studies is 125 I-labelled salmon calcitonin. The lack of methionine residues in this peptide permits the use of chloramine-T for the iodination reaction. Binding assays are described for intact bone, skeletal plasma membranes, renal plasma membranes, and primary kidney cell cultures of rats. Studies on calcitonin metabolism in laboratory animals and regulation of calcitonin receptors are reviewed

  9. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  10. Microchemiluminescent assay system

    Energy Technology Data Exchange (ETDEWEB)

    Kiel, J.L.

    1986-04-09

    The patent concerns a microchemiluminescent assay system, which can be used to detect ionizing radiation, heat or specific substances. The method involves the use of a complex formed from serum albumin and a luminescer which, in the presence of ionizing radiation (heat, or a specific analyte), will emit light in an amount proportional to the amount of radiation, etc. (U.K.).

  11. (MTT) dye reduction assay.

    African Journals Online (AJOL)

    to inhibit proliferation of HeLa cells was determined using the 3443- dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) dye reduction assay. Extracts from roots of Agathisanthemum bojeri, Synaptolepis kirkii and Zanha africana and the leaf extract of Physalis peruviana at a concentration of 10 pg/ml inhibited cell ...

  12. Hyaluronic Acid Assays

    DEFF Research Database (Denmark)

    Itenov, Theis S; Kirkby, Nikolai S; Bestle, Morten H

    2015-01-01

    BACKGROUD: Hyaluronic acid (HA) is proposed as a marker of functional liver capacity. The aim of the present study was to compare a new turbidimetric assay for measuring HA with the current standard method. METHODS: HA was measured by a particle-enhanced turbidimetric immunoassay (PETIA) and enzyme...

  13. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  14. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  15. Radioreceptor assay for oxyphenonium

    International Nuclear Information System (INIS)

    Ensing, K.; Zeeuw, R.A. de

    1984-01-01

    The development of a radioreceptor assay for the quaternary anticholinergic drug, oxyphenonium, in plasma is reported. It is based on competition between this drug and 3 H-dexetimide for binding to muscarinic receptors. After ion pair extraction and reextraction, the drug can be determined in plasma at concentrations down to a value of 100 pg/ml. This permits pharmacokinetic studies to be made after inhalation of oxyphenonium. (author)

  16. Dual isotope assays

    International Nuclear Information System (INIS)

    Smith, G.F.W.; Stevens, R.A.J.; Jacoby, B.

    1980-01-01

    Dual isotope assays for thyroid function are performed by carrying out a radio-immunoassay for two of thyroxine (T4), tri-iodothyronine (T3), thyroid stimulating hormone (TSH), and thyroxine binding globulin (TBG), by a method wherein a version of one of the thyroid components, preferably T4 or T3 is labelled with Selenium-75 and the version of the other thyroid component is labelled with a different radionuclide, preferably Iodine-125. (author)

  17. Biodiesel Mass Transit Demonstration

    Science.gov (United States)

    2010-04-01

    The Biodiesel Mass Transit Demonstration report is intended for mass transit decision makers and fleet managers considering biodiesel use. This is the final report for the demonstration project implemented by the National Biodiesel Board under a gran...

  18. Authoring Effective Demonstrations

    National Research Council Canada - National Science Library

    Fu, Dan; Jensen, Randy; Salas, Eduardo; Rosen, Michael A; Ramachandran, Sowmya; Upshaw, Christin L; Hinkelman, Elizabeth; Lampton, Don

    2007-01-01

    ... or human role-players for each training event. We report our ongoing efforts to (1) research the nature and purpose of demonstration, articulating guidelines for effective demonstration within a training context, and (2...

  19. Comparing Demonstratives in Kwa

    African Journals Online (AJOL)

    This paper is a comparative study of demonstrative forms in three K wa languages, ... relative distance from the deictic centre, such as English this and that, here and there. ... Mostly, the referents of demonstratives are 'activated' or at least.

  20. Polarized Light Corridor Demonstrations.

    Science.gov (United States)

    Davies, G. R.

    1990-01-01

    Eleven demonstrations of light polarization are presented. Each includes a brief description of the apparatus and the effect demonstrated. Illustrated are strain patterns, reflection, scattering, the Faraday Effect, interference, double refraction, the polarizing microscope, and optical activity. (CW)

  1. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  2. Strategy Guideline: Demonstration Home

    Energy Technology Data Exchange (ETDEWEB)

    Savage, C.; Hunt, A.

    2012-12-01

    This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

  3. Strategy Guideline. Demonstration Home

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Savage, C.

    2012-12-01

    This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

  4. Assay of cysteine dioxygenase activity

    International Nuclear Information System (INIS)

    Bagley, P.J.; Stipanuk, M.H.

    1990-01-01

    It has been proposed that rat liver contains two cysteine dioxygenase enzymes which convert cysteine to cysteinesulfinic acid, one which is stimulated by NAD + and has a pH optimum of 6.8 and one which is not stimulated by NAD + and has a pH optimum of 9.0. This led the authors to reinvestigate assay conditions for measuring cysteine dioxygenase activity in rat liver homogenate. An HPLC method, using an anion exchange column (Dionex Amino-Pac trademark PA1 (4x250 mm)) was used to separate the [ 35 S]cysteinesulfinic acid produced from [ 35 S]cysteine in the incubation mixture. They demonstrated that inclusion of hydroxylamine prevented further metabolism of cysteinesulfinic acid. which occurred rapidly in the absence of hydroxylamine

  5. Radiorespirometic assay device

    International Nuclear Information System (INIS)

    Levin, G.V.; Straat, P.A.

    1981-01-01

    A radiorespirometic assay device is described in which the presence of microorganisms in a sample is determined by placing the sample in contact with a metabolisable radioactive labelled substrate, collecting any gas evolved, exposing a photosensitive material to the gas and determining if a spot is produced on the material. A spot indicates the presence of radioactivity showing that the substrate has been metabolized by a microorganism. Bacteria may be detected in body fluids, hospital operating rooms, water, food, cosmetics and drugs. (U.K.)

  6. Radon assay for SNO+

    Energy Technology Data Exchange (ETDEWEB)

    Rumleskie, Janet [Laurentian University, Greater Sudbury, Ontario (Canada)

    2015-12-31

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+.

  7. Manufacturing Demonstration Facility (MDF)

    Data.gov (United States)

    Federal Laboratory Consortium — The U.S. Department of Energy Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides a collaborative, shared infrastructure to...

  8. Assay of low-level plutonium effluents

    International Nuclear Information System (INIS)

    Hsue, S.T.; Hsue, F.; Bowersox, D.F.

    1981-01-01

    In the plutonium recovery section at the Los Alamos National Laboratory, an effluent solution is generated that contains low plutonium concentration and relatively high americium concentration. Nondestructive assay of this solution is demonstrated by measuring the passive L x-rays following alpha decay. Preliminary results indicate that an average deviation of 30% between L x-ray and alpha counting can be achieved for plutonium concentrations above 10 mg/L and Am/Pu ratios of up to 3; for plutonium concentrations less than 10 mg/L, the average deviation is 40%. The sensitivity of the L x-ray assay is approx. 1 mg Pu/L

  9. RAS - Screens & Assays - Drug Discovery

    Science.gov (United States)

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  10. Improving shuffler assay accuracy

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-01-01

    Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year

  11. Competitive protein binding assay

    International Nuclear Information System (INIS)

    Kaneko, Toshio; Oka, Hiroshi

    1975-01-01

    The measurement of cyclic GMP (cGMP) by competitive protein binding assay was described and discussed. The principle of binding assay was represented briefly. Procedures of our method by binding protein consisted of preparation of cGMP binding protein, selection of 3 H-cyclic GMP on market, and measurement procedures. In our method, binding protein was isolated from the chrysalis of silk worm. This method was discussed from the points of incubation medium, specificity of binding protein, the separation of bound cGMP from free cGMP, and treatment of tissue from which cGMP was extracted. cGMP existing in the tissue was only one tenth or one scores of cGMP, and in addition, cGMP competed with cGMP in binding with binding protein. Therefore, Murad's technique was applied to the isolation of cGMP. This method provided the measurement with sufficient accuracy; the contamination by cAMP was within several per cent. (Kanao, N.)

  12. An enzyme-linked immuno-filtration assay used to compare infant and maternal antibody profiles in toxoplasmosis.

    Science.gov (United States)

    Pinon, J M; Thoannes, H; Gruson, N

    1985-02-28

    Enzyme-linked immuno-filtration assay is carried out on a micropore membrane. This doubly analytical technique permits simultaneous study of antibody specificity by immunoprecipitation and characterisation of antibody isotypes by immuno-filtration with enzyme-labelled antibodies. Recognition of the same T. gondii antigenic constituent by IgG, IgA, IgM or IgE antibodies produces couplets (IgG-IgM; IgG-IgA) or triplets (IgG-IgM-IgA; IgG-IgM-IgE) which identify the functional fractions of the toxoplasmosis antigen. In acquired toxoplasmosis, the persistence of IgM antibody long after infestation puts in question the implication of recent infestation normally linked to detection of this isotype. For sera of comparable titres, comparison of immunological profiles by the method described demonstrates disparities in the composition of the specific antibody content as expressed in international units. Use of the same method to detect IgM antibodies or distinguish between transmitted maternal IgG and IgG antibodies synthesised by the foetus or neonate makes a diagnosis of congenital toxoplasmosis possible in 85% of cases during the first few days of life. With the method described the diagnosis may be made on average 5 months earlier than with classical techniques. In the course of surveillance for latent congenital toxoplasmosis, the appearance of IgM or IgE antibodies raises the possibility of complications (hydrocephalus, chorioretinitis). After cessation of treatment, a rise in IgG antibodies indicating persistence of infection is detected earlier by the present than by classical methods.

  13. An improved plating assay for determination of phage titer | Yang ...

    African Journals Online (AJOL)

    In this study, an improved plating assay was developed for detection of the number of recombinant phage Cap-T7 present in a test solution at a certain dilution point by counting the plaque forming units. The data demonstrated that the improved plating assay is fast, useful, and convenient for the determination of the phage ...

  14. The single-cell gel electrophoresis assay to determine apoptosis ...

    African Journals Online (AJOL)

    When the frequency of appearance of apoptotic cells following was observed over a period of time, there was a significant increase in appearance of apoptosis when using single cell gel electrophoresis assay. The present report demonstrates that the characteristic pattern of apoptotic comets detected by the comet assay ...

  15. Assay of oestrogen

    International Nuclear Information System (INIS)

    Edwards, J.C.

    1981-01-01

    A particular problem with the direct radioimmunoassay of unconjugated oestriol in pregnancy is caused by the increased amount of steroid-binding proteins present in pregnancy serum and plasma. The steroid-binding proteins react with oestriol and 125 I-labelled oestriol during the assay procedure and the steroid-protein bound 125 I-labelled oestriol is precipitated along with the antibody-bound 125 I-labelled oestriol by the ammonium sulphate solution separation system. A novel method is described whereby progesterone (1-20 μg/ml) is used to block the action of steroid-binding proteins in pregnancy serum and plasma samples, thus minimizing interference in a direct radioimmunoassay for unconjugated oestriol using a specific anti-oestriol serum. (U.K.)

  16. Innovative technology demonstration

    International Nuclear Information System (INIS)

    Anderson, D.B.; Luttrell, S.P.; Hartley, J.N.; Hinchee, R.

    1992-04-01

    The Innovative Technology Demonstration (ITD) program at Tinker Air Force Base (TAFB), Oklahoma City, Oklahoma, will demonstrate the overall utility and effectiveness of innovative technologies for site characterization, monitoring, and remediation of selected contaminated test sites. The current demonstration test sites include a CERCLA site on the NPL list, located under a building (Building 3001) that houses a large active industrial complex used for rebuilding military aircraft, and a site beneath and surrounding an abandoned underground tank vault used for storage of jet fuels and solvents. The site under Building 3001 (the NW Test Site) is contaminated with TCE and Cr +6 ; the site with the fuel storage vault (the SW Tanks Site) is contaminated with fuels, BTEX and TCE. These sites and others have been identified for cleanup under the Air Force's Installation Restoration Program (IRP). This document describes the demonstrations that have been conducted or are planned for the TAFB

  17. Laser Communications Relay Demonstration

    Data.gov (United States)

    National Aeronautics and Space Administration — LCRD is a minimum two year flight demonstration in geosynchronous Earth orbit to advance optical communications technology toward infusion into Deep Space and Near...

  18. Spacecraft Fire Safety Demonstration

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Spacecraft Fire Safety Demonstration project is to develop and conduct large-scale fire safety experiments on an International Space Station...

  19. Education Payload Operation - Demonstrations

    Science.gov (United States)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Demonstrations (EPO-Demos) are recorded video education demonstrations performed on the International Space Station (ISS) by crewmembers using hardware already onboard the ISS. EPO-Demos are videotaped, edited, and used to enhance existing NASA education resources and programs for educators and students in grades K-12. EPO-Demos are designed to support the NASA mission to inspire the next generation of explorers.

  20. Buried Waste Integrated Demonstration

    International Nuclear Information System (INIS)

    1994-03-01

    The Buried Waste Integrated Demonstration (BWID) supports the applied research, development, demonstration, and evaluation of a suite of advanced technologies that offer promising solutions to the problems associated with the remediation of buried waste. BWID addresses the difficult remediation problems associated with DOE complex-wide buried waste, particularly transuranic (TRU) contaminated buried waste. BWID has implemented a systems approach to the development and demonstration of technologies that will characterize, retrieve, treat, and dispose of DOE buried wastes. This approach encompasses the entire remediation process from characterization to post-monitoring. The development and demonstration of the technology is predicated on how a technology fits into the total remediation process. To address all of these technological issues, BWID has enlisted scientific expertise of individuals and groups from within the DOE Complex, as well as experts from universities and private industry. The BWID mission is to support development and demonstration of a suite of technologies that, when integrated with commercially-available technologies, forms a comprehensive, remediation system for the effective and efficient remediation of buried waste throughout the DOE Complex. BWID will evaluate and validate demonstrated technologies and transfer this information and equipment to private industry to support the Office of Environmental Restoration (ER), Office of Waste Management (WM), and Office of Facility Transition (FT) remediation planning and implementation activities

  1. Introducing MINA--The Molecularly Imprinted Nanoparticle Assay.

    Science.gov (United States)

    Shutov, Roman V; Guerreiro, Antonio; Moczko, Ewa; de Vargas-Sansalvador, Isabel Perez; Chianella, Iva; Whitcombe, Michael J; Piletsky, Sergey A

    2014-03-26

    A new ELISA- (enzyme-linked immunosorbent assay)-like assay is demonstrated in which no elements of biological origin are used for molecular recognition or signaling. Composite imprinted nanoparticles that contain a catalytic core and which are synthesized by using a solid-phase approach can simultaneously act as recognition/signaling elements, and be used with minimal modifications to standard assay protocols. This assay provides a new route towards replacement of unstable biomolecules in immunoassays. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Learning From Demonstration?

    DEFF Research Database (Denmark)

    Koch, Christian; Bertelsen, Niels Haldor

    2014-01-01

    Demonstration projects are often used in the building sector to provide a basis for using new processes and/or products. The climate change agenda implies that construction is not only required to deliver value for the customer, cost reductions and efficiency but also sustainable buildings....... This paper reports on an early demonstration project, the Building of a passive house dormitory in the Central Region of Denmark in 2006-2009. The project was supposed to deliver value, lean design, prefabrication, quality in sustainability, certification according to German standards for passive houses......, and micro combined heat and power using hydrogen. Using sociological and business economic theories of innovation, the paper discusses how early movers of innovation tend to obtain only partial success when demonstrating their products and often feel obstructed by minor details. The empirical work...

  3. Solar renovation demonstration projects

    Energy Technology Data Exchange (ETDEWEB)

    Bruun Joergensen, O [ed.

    1998-10-01

    In the framework of the IEA SHC Programme, a Task on building renovation was initiated, `Task 20, Solar Energy in Building Renovation`. In a part of the task, Subtask C `Design of Solar Renovation Projects`, different solar renovation demonstration projects were developed. The objective of Subtask C was to demonstrate the application of advanced solar renovation concepts on real buildings. This report documents 16 different solar renovation demonstration projects including the design processes of the projects. The projects include the renovation of houses, schools, laboratories, and factories. Several solar techniques were used: building integrated solar collectors, glazed balconies, ventilated solar walls, transparent insulation, second skin facades, daylight elements and photovoltaic systems. These techniques are used in several simple as well as more complex system designs. (au)

  4. Biodenitrification demonstration test report

    International Nuclear Information System (INIS)

    Benear, A.K.; Murray, S.J.; Lahoda, E.J.; Leslie, J.W.; Patton, J.B.; Menako, C.R.

    1987-08-01

    A two-column biodenitrification (BDN) facility was constructed at the Feed Materials Production Center (FMPC) in 1985 and 1986 to test the feasibility of biological treatment for industrial nitrate-bearing waste water generated at FMPC. This demonstration facility comprises one-half of the proposed four-column production facility. A demonstration test was conducted over a four month period in 1987. The results indicate the proposed BDN production facility can process FMPC industrial wastewater in a continuous manner while maintaining an effluent that will consistently meet the proposed NPDES limits for combined nitrate nitrogen (NO 3 -N) and nitrite nitrogen (NO 2 -N). The proposed NPDES limits are 62 kg/day average and 124 kg/day maximum. These limits were proportioned to determine that the two-column demonstration facility should meet the limits of 31 kg/day average and 62 kg/day maximum

  5. Distributed picture compilation demonstration

    Science.gov (United States)

    Alexander, Richard; Anderson, John; Leal, Jeff; Mullin, David; Nicholson, David; Watson, Graham

    2004-08-01

    A physical demonstration of distributed surveillance and tracking is described. The demonstration environment is an outdoor car park overlooked by a system of four rooftop cameras. The cameras extract moving objects from the scene, and these objects are tracked in a decentralized way, over a real communication network, using the information form of the standard Kalman filter. Each node therefore has timely access to the complete global picture and because there is no single point of failure in the system, it is robust. The demonstration system and its main components are described here, with an emphasis on some of the lessons we have learned as a result of applying a corpus of distributed data fusion theory and algorithms in practice. Initial results are presented and future plans to scale up the network are also outlined.

  6. Photovoltaic demonstration projects

    Energy Technology Data Exchange (ETDEWEB)

    Gillett, W B; Hacker, R J; Kaut, W [eds.

    1991-01-01

    This book, the proceedings of the fourth PV-Contractors' Meeting organized by the Commission of the European Communities, Directorate-General for Energy, held at Brussels on 21 and 22 November 1989, provides an overview of the photovoltaic demonstration projects which have been supported in the framework of the Energy Demonstration Program since 1983. It includes reports by each of the contractors who submitted proposals in 1983, 1984, 1985 and 1986, describing progress with their projects. Summaries of the discussions held at the meeting, which included contractors whose projects were submitted in 1987, are also presented. The different technologies which are being demonstrated concern the modules, the cabling of the array, structure design, storage strategy and power conditioning. The various applications include desalination, communications, dairy farms, water pumping, and warning systems. Papers have been processed separately for inclusion on the data base.

  7. Electric vehicle demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Ouellet, M. [National Centre for Advanced Transportation, Saint-Jerome, PQ (Canada)

    2010-07-01

    The desirable characteristics of Canadian projects that demonstrate vehicle use in real-world operation and the appropriate mechanism to collect and disseminate the monitoring data were discussed in this presentation. The scope of the project was on passenger cars and light duty trucks operating in plug-in electric vehicle (PHEV) or battery electric vehicle modes. The presentation also discussed the funding, stakeholders involved, Canadian travel pattern analysis, regulatory framework, current and recent electric vehicle demonstration projects, and project guidelines. It was concluded that some demonstration project activities may have been duplicated as communication between the proponents was insufficient. It was recommended that data monitoring using automatic data logging with minimum reliance on logbooks and other user entry should be emphasized. figs.

  8. Innovative technology demonstrations

    International Nuclear Information System (INIS)

    Anderson, D.B.; Luttrell, S.P.; Hartley, J.N.

    1992-08-01

    Environmental Management Operations (EMO) is conducting an Innovative Technology Demonstration Program for Tinker Air Force Base (TAFB). Several innovative technologies are being demonstrated to address specific problems associated with remediating two contaminated test sites at the base. Cone penetrometer testing (CPT) is a form of testing that can rapidly characterize a site. This technology was selected to evaluate its applicability in the tight clay soils and consolidated sandstone sediments found at TAFB. Directionally drilled horizontal wells was selected as a method that may be effective in accessing contamination beneath Building 3001 without disrupting the mission of the building, and in enhancing the extraction of contamination both in ground water and in soil. A soil gas extraction (SGE) demonstration, also known as soil vapor extraction, will evaluate the effectiveness of SGE in remediating fuels and TCE contamination contained in the tight clay soil formations surrounding the abandoned underground fuel storage vault located at the SW Tanks Site. In situ sensors have recently received much acclaim as a technology that can be effective in remediating hazardous waste sites. Sensors can be useful for determining real-time, in situ contaminant concentrations during the remediation process for performance monitoring and in providing feedback for controlling the remediation process. Following the SGE demonstration, the SGE system and SW Tanks test site will be modified to demonstrate bioremediation as an effective means of degrading the remaining contaminants in situ. The bioremediation demonstration will evaluate a bioventing process in which the naturally occurring consortium of soil bacteria will be stimulated to aerobically degrade soil contaminants, including fuel and TCE, in situ

  9. Innovative technology demonstrations

    International Nuclear Information System (INIS)

    Anderson, D.B.; Hartley, J.N.; Luttrell, S.P.

    1992-04-01

    Currently, several innovative technologies are being demonstrated at Tinker Air Force Base (TAFB) to address specific problems associated with remediating two contaminated test sites at the base. Cone penetrometer testing (CPT) is a form of testing that can rapidly characterize a site. This technology was selected to evaluate its applicability in the tight clay soils and consolidated sandstone sediments found at TAFB. Directionally drilled horizontal wells have been successfully installed at the US Department of Energy's (DOE) Savannah River Site to test new methods of in situ remediation of soils and ground water. This emerging technology was selected as a method that may be effective in accessing contamination beneath Building 3001 without disrupting the mission of the building, and in enhancing the extraction of contamination both in ground water and in soil. A soil gas extraction (SGE) demonstration, also known as soil vapor extraction, will evaluate the effectiveness of SGE in remediating fuels and TCE contamination contained in the tight clay soil formations surrounding the abandoned underground fuel storage vault located at the SW Tanks Site. In situ sensors have recently received much acclaim as a technology that can be effective in remediating hazardous waste sites. Sensors can be useful for determining real-time, in situ contaminant concentrations during the remediation process for performance monitoring and in providing feedback for controlling the remediation process. A demonstration of two in situ sensor systems capable of providing real-time data on contamination levels will be conducted and evaluated concurrently with the SGE demonstration activities. Following the SGE demonstration, the SGE system and SW Tanks test site will be modified to demonstrate bioremediation as an effective means of degrading the remaining contaminants in situ

  10. Techniques for laser processing, assay, and examination of spent fuel

    International Nuclear Information System (INIS)

    Gray, J.H.; Mitchell, R.C.; Rogell, M.L.

    1981-11-01

    Fuel examination studies were performed which have application to interim spent fuel storage. These studies were in three areas, i.e., laser drilling and rewelding demonstration, nondestructive assay techniques survey, and fuel examination techniques survey

  11. Gigashot Optical Laser Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Deri, R. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-13

    The Gigashot Optical Laser Demonstrator (GOLD) project has demonstrated a novel optical amplifier for high energy pulsed lasers operating at high repetition rates. The amplifier stores enough pump energy to support >10 J of laser output, and employs conduction cooling for thermal management to avoid the need for expensive and bulky high-pressure helium subsystems. A prototype amplifier was fabricated, pumped with diode light at 885 nm, and characterized. Experimental results show that the amplifier provides sufficient small-signal gain and sufficiently low wavefront and birefringence impairments to prove useful in laser systems, at repetition rates up to 60 Hz.

  12. Photovoltaic demonstration projects 2

    Energy Technology Data Exchange (ETDEWEB)

    Gillett, W B; Hacker, R J [Halcrow (William) and Partners, Swindon (UK); Kaut, W [eds.

    1989-01-01

    This book, the proceedings of the third Photovoltaic Contractors' Meeting organised by the Commission of the European Communities, Directorate-General for Energy provides an overview of the photovoltaic demonstration projects which have been supported by the Energy Directorate of the Commission of the European Communities since 1983. It includes reports by each of the contractors who submitted proposals in 1983, 1984 and 1985, describing progress with their projects. The different technologies which are being demonstrated concern the modules, the cabling of the array, structure design, storage strategy and power conditioning. The various applications include powering of houses, villages, recreation centres, water desalination, communications, dairy farms, water pumping and warning systems. (author).

  13. Two-Phase Microfluidic Systems for High Throughput Quantification of Agglutination Assays

    KAUST Repository

    Castro, David

    2018-01-01

    assay, with a minimum detection limit of 50 ng/mL using optical image analysis. We compare optical image analysis and light scattering as quantification methods, and demonstrate the first light scattering quantification of agglutination assays in a two

  14. Evaluation of a MTT assay in measurement of radiosensitizing effect

    International Nuclear Information System (INIS)

    Higuchi, Keiko; Mitsuhashi, Norio; Saitoh, Jun-ichi; Maebayashi, Katsuya; Sakurai, Hideyuki; Akimoto, Tetsuo; Niibe, Hideo

    1999-01-01

    The usefulness of a MTT assay by measuring the radiosensitizing effect of caffeine on rat yolk sac tumor cell line with a mutant-type p53 in vitro was evaluated. A rat yolk sac tumor cell line with a mutant-type p53, NMT-1R, was used in this study. The radiosensitivity of NMT-1R with or without caffeine was measured with a MTT assay. The results were compared with those by a clonogenic assay. Caffeine at a concentration of 2.0 mM which released radiation-induced G 2 block demonstrated a radiosensitizing effect, but caffeine at a concentration of 0.5 mM did not. The radiosensitizing effect of caffeine measured by a MTT assay correlated with that measured by a clonogenic assay. A MTT assay was useful to measure radiosensitivity and/or a radiosensitizing effect in vitro. (author)

  15. Inseparable Phone Books Demonstration

    Science.gov (United States)

    Balta, Nuri; Çetin, Ali

    2017-01-01

    This study is aimed at first introducing a well-known discrepant event; inseparable phone books and second, turning it into an experiment for high school or middle school students. This discrepant event could be used especially to indicate how friction force can be effective in producing an unexpected result. Demonstration, discussion, explanation…

  16. PHARUS ASAR demonstrator

    NARCIS (Netherlands)

    Smith, A.J.E.; Bree, R.J.P. van; Calkoen, C.J.; Dekker, R.J.; Otten, M.P.G.; Rossum, W.L. van

    2001-01-01

    PHARUS is a polarimetric phased array C-band Synthetic Aperture Radar (SAR), designed and built for airborne use. Advanced SAR (ASAR) data in image and alternating polarization mode have been simulated with PHARUS to demonstrate the use of Envisat for a number of typical SAR applications that are

  17. Demonstrating the Gas Laws.

    Science.gov (United States)

    Holko, David A.

    1982-01-01

    Presents a complete computer program demonstrating the relationship between volume/pressure for Boyle's Law, volume/temperature for Charles' Law, and volume/moles of gas for Avagadro's Law. The programing reinforces students' application of gas laws and equates a simulated moving piston to theoretical values derived using the ideal gas law.…

  18. Astronomy LITE Demonstrations

    Science.gov (United States)

    Brecher, Kenneth

    2006-12-01

    Project LITE (Light Inquiry Through Experiments) is a materials, software, and curriculum development project. It focuses on light, optics, color and visual perception. According to two recent surveys of college astronomy faculty members, these are among the topics most often included in the large introductory astronomy courses. The project has aimed largely at the design and implementation of hands-on experiences for students. However, it has also included the development of lecture demonstrations that employ novel light sources and materials. In this presentation, we will show some of our new lecture demonstrations concerning geometrical and physical optics, fluorescence, phosphorescence and polarization. We have developed over 200 Flash and Java applets that can be used either by teachers in lecture settings or by students at home. They are all posted on the web at http://lite.bu.edu. For either purpose they can be downloaded directly to the user's computer or run off line. In lecture demonstrations, some of these applets can be used to control the light emitted by video projectors to produce physical effects in materials (e.g. fluorescence). Other applets can be used, for example, to demonstrate that the human percept of color does not have a simple relationship with the physical frequency of the stimulating source of light. Project LITE is supported by Grant #DUE-0125992 from the NSF Division of Undergraduate Education.

  19. A Magnetic Circuit Demonstration.

    Science.gov (United States)

    Vanderkooy, John; Lowe, June

    1995-01-01

    Presents a demonstration designed to illustrate Faraday's, Ampere's, and Lenz's laws and to reinforce the concepts through the analysis of a two-loop magnetic circuit. Can be made dramatic and challenging for sophisticated students but is suitable for an introductory course in electricity and magnetism. (JRH)

  20. A quantitative comet infection assay for influenza virus

    Science.gov (United States)

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    Summary The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold increase in sensitivity to ribavirin. AX4 cells (MDCK cells with increased surface concentration of α2–6 sialic acid, the influenza virus receptor) have reduced the comet size variability relative to MDCK cells, making them a better host cell for use in this assay. Because of enhanced antiviral sensitivity in flow-based assays, less drug is required, which could lead to lower reagent costs, reduced cytotoxicity, and fewer false-negative drug screen results. The comet assay also serves as a readout of flow conditions in the well. Observations from comets formed at varying humidity levels indicate a role for evaporation in the mechanism of spontaneous fluid flow in wells. PMID:22155578

  1. The comet assay: ready for 30 more years.

    Science.gov (United States)

    Møller, Peter

    2018-02-24

    During the last 30 years, the comet assay has become widely used for the measurement of DNA damage and repair in cells and tissues. A landmark achievement was reached in 2016 when the Organization for Economic Co-operation and Development adopted a comet assay guideline for in vivo testing of DNA strand breaks in animals. However, the comet assay has much more to offer than being an assay for testing DNA strand breaks in animal organs. The use of repair enzymes increases the range of DNA lesions that can be detected with the assay. It can also be modified to measure DNA repair activity. Still, despite the long-term use of the assay, there is a need for studies that assess the impact of variation in specific steps of the procedure. This is particularly important for the on-going efforts to decrease the variation between experiments and laboratories. The articles in this Special Issue of Mutagenesis cover important technical issues of the comet assay procedure, nanogenotoxicity and ionising radiation sensitivity on plant cells. The included biomonitoring studies have assessed seasonal variation and certain predictors for the basal level of DNA damage in white blood cells. Lastly, the comet assay has been used in studies on genotoxicity of environmental and occupational exposures in human biomonitoring studies and animal models. Overall, the articles in this Special Issue demonstrate the versatility of the comet assay and they hold promise that the assay is ready for the next 30 years.

  2. Remote monitoring demonstration

    International Nuclear Information System (INIS)

    Caskey, Susan; Olsen, John

    2006-01-01

    The recently upgraded remote monitoring system at the Joyo Experimental Reactor uses a DCM-14 camera module and GEMINI software. The final data is compatible both with the IAEA-approved GARS review software and the ALIS software that was used for this demonstration. Features of the remote monitoring upgrade emphasized compatibility with IAEA practice. This presentation gives particular attention to the selection process for meeting network security considerations at the O'arai site. The Joyo system is different from the NNCA's ACPF system, in that it emphasizes use of IAEA standard camera technology and data acquisition and transmission software. In the demonstration itself, a temporary virtual private network (VPN) between the meeting room and the server at Sandia in Albuquerque allowed attendees to observe data stored from routine transmissions from the Joyo Fresh Fuel Storage to Sandia. Image files from a fuel movement earlier in the month showed Joyo workers and IAEA inspectors carrying out a transfer. (author)

  3. Commercial incineration demonstration

    International Nuclear Information System (INIS)

    Borduin, L.C.; Neuls, A.S.

    1981-01-01

    Low-level radioactive wastes (LLW) generated by nuclear utilities presently are shipped to commercial burial grounds for disposal. Substantially increasing shipping and disposal charges have sparked renewed industry interest in incineration and other advanced volume reduction techniques as potential cost-saving measures. Repeated inquiries from industry sources regarding LLW applicability of the Los Alamos controlled-air incineration (CAI) design led DOE to initiate this commercial demonstration program in FY-1980. The selected program approach to achieving CAI demonstration at a utility site is a DOE sponsored joint effort involving Los Alamos, a nuclear utility, and a liaison subcontractor. Required development tasks and responsibilities of the particpants are described. Target date for project completion is the end of FY-1985

  4. Photovoltaic demonstration projects

    Energy Technology Data Exchange (ETDEWEB)

    Kaut, W [Commission of the European Communities, Brussels (Belgium); Gillett, W B; Hacker, R J [Halcrow Gilbert Associates Ltd., Swindon (GB)

    1992-12-31

    This publication, comprising the proceedings of the fifth contractor`s meeting organized by the Commission of the European Communities, Directorate-General for Energy, provides an overview of the photovoltaic demonstration projects which have been supported in the framework of the energy demonstration programme since 1983. It includes reports by each of the contractors who submitted proposals in 1987 and 1988, describing progress within their projects. Projects accepted from earlier calls for proposals and not yet completed were reviewed by a rapporteur and are discussed in the summary section. The results of the performance monitoring of all projects and the lessons drawn from the practical experience of the projects are also presented in the summaries and conclusions. Contractors whose projects were submitted in 1989 were also present at the meeting and contributed to the reported discussions. This proceeding is divided into four sessions (General, Housing, technical presentations, other applications) and 24 papers are offered.

  5. AVNG system demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Thron, Jonathan Louis [Los Alamos National Laboratory; Mac Arthur, Duncan W [Los Alamos National Laboratory; Kondratov, Sergey [VNIIEF; Livke, Alexander [VNIIEF; Razinkov, Sergey [VNIIEF

    2010-01-01

    An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By only displaying these unclassified results as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG implementation that we describe is an AMS built by RFNC - VNIIEF in Sarov, Russia. To provide additional confidence, the AVNG was designed with two modes of operation. In the secure mode, potentially classified measurements can be made with only the simple red light/green light display. In the open mode, known unclassified material can be measured with complete display of the information collected from the radiation detectors. The AVNG demonstration, which occurred in Sarov, Russia in June 2009 for a joint US/Russian audience, included exercising both modes of AVNG operation using a number of multi-kg plutonium sources. In addition to describing the demonstration, we will show photographs and/or video taken of AVNG operation.

  6. Antares: preliminary demonstrator results

    International Nuclear Information System (INIS)

    Kouchner, A.

    2000-05-01

    The ANTARES collaboration is building an undersea neutrino telescope off Toulon (Mediterranean sea) with effective area ∼ 0.1 km 2 . An extensive study of the site properties has been achieved together with software analysis in order to optimize the performance of the detector. Results are summarized here. An instrumented line, linked to shore for first time via an electro-optical cable, has been immersed late 1999. The preliminary results of this demonstrator line are reported. (author)

  7. The Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Aguayo, Estanislao; Fast, James E.; Hoppe, Eric W.; Keillor, Martin E.; Kephart, Jeremy D.; Kouzes, Richard T.; LaFerriere, Brian D.; Merriman, Jason H.; Orrell, John L.; Overman, Nicole R.; Avignone, Frank T.; Back, Henning O.; Combs, Dustin C.; Leviner, L.; Young, A.; Barabash, Alexander S.; Konovalov, S.; Vanyushin, I.; Yumatov, Vladimir; Bergevin, M.; Chan, Yuen-Dat; Detwiler, Jason A.; Loach, J. C.; Martin, R. D.; Poon, Alan; Prior, Gersende; Vetter, Kai; Bertrand, F.; Cooper, R. J.; Radford, D. C.; Varner, R. L.; Yu, Chang-Hong; Boswell, M.; Elliott, S.; Gehman, Victor M.; Hime, Andrew; Kidd, M. F.; LaRoque, B. H.; Rielage, Keith; Ronquest, M. C.; Steele, David; Brudanin, V.; Egorov, Viatcheslav; Gusey, K.; Kochetov, Oleg; Shirchenko, M.; Timkin, V.; Yakushev, E.; Busch, Matthew; Esterline, James H.; Tornow, Werner; Christofferson, Cabot-Ann; Horton, Mark; Howard, S.; Sobolev, V.; Collar, J. I.; Fields, N.; Creswick, R.; Doe, Peter J.; Johnson, R. A.; Knecht, A.; Leon, Jonathan D.; Marino, Michael G.; Miller, M. L.; Robertson, R. G. H.; Schubert, Alexis G.; Wolfe, B. A.; Efremenko, Yuri; Ejiri, H.; Hazama, R.; Nomachi, Masaharu; Shima, T.; Finnerty, P.; Fraenkle, Florian; Giovanetti, G. K.; Green, M.; Henning, Reyco; Howe, M. A.; MacMullin, S.; Phillips, D.; Snavely, Kyle J.; Strain, J.; Vorren, Kris R.; Guiseppe, Vincente; Keller, C.; Mei, Dong-Ming; Perumpilly, Gopakumar; Thomas, K.; Zhang, C.; Hallin, A. L.; Keeter, K.; Mizouni, Leila; Wilkerson, J. F.

    2011-09-03

    A brief review of the history and neutrino physics of double beta decay is given. A description of the MAJORANA DEMONSTRATOR research and development program, including background reduction techniques, is presented in some detail. The application of point contact (PC) detectors to the experiment is discussed, including the effectiveness of pulse shape analysis. The predicted sensitivity of a PC detector array enriched to 86% to 76Ge is given.

  8. IGCC technology and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, J [A. Ahlstrom Corporation, Karhula (Finland). Hans Ahlstrom Lab.; Lundqvist, R G [A. Ahlstrom Corporation, Helsinki (Finland); Staahl, K [Sydkraft AB, Malmoe (Sweden)

    1997-12-31

    Future energy production will be performed by advanced technologies that are more efficient, more environmentally friendly and less expensive than current technologies. Integrated gasification combined cycle (IGCC) power plants have been proposed as one of these systems. Utilising biofuels in future energy production will also be emphasised since this lowers substantially carbon dioxide emissions into the atmosphere due to the fact that biomass is a renewable form of energy. Combining advanced technology and biomass utilisation is for this reason something that should and will be encouraged. A. Ahlstrom Corporation of Finland and Sydkraft AB of Sweden have as one part of company strategies adopted this approach for the future. The companies have joined their resources in developing a biomass-based IGCC system with the gasification part based on pressurised circulating fluidized-bed technology. With this kind of technology electrical efficiency can be substantially increased compared to conventional power plants. As a first concrete step, a decision has been made to build a demonstration plant. This plant, located in Vaernamo, Sweden, has already been built and is now in commissioning and demonstration stage. The system comprises a fuel drying plant, a pressurised CFB gasifier with gas cooling and cleaning, a gas turbine, a waste heat recovery unit and a steam turbine. The plant is the first in the world where the integration of a pressurised gasifier with a gas turbine will be realised utilising a low calorific gas produced from biomass. The capacity of the Vaernamo plant is 6 MW of electricity and 9 MW of district heating. Technology development is in progress for design of plants of sizes from 20 to 120 MWe. The paper describes the Bioflow IGCC system, the Vaernamo demonstration plant and experiences from the commissioning and demonstration stages. (orig.)

  9. IGCC technology and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, J. [A. Ahlstrom Corporation, Karhula (Finland). Hans Ahlstrom Lab.; Lundqvist, R.G. [A. Ahlstrom Corporation, Helsinki (Finland); Staahl, K. [Sydkraft AB, Malmoe (Sweden)

    1996-12-31

    Future energy production will be performed by advanced technologies that are more efficient, more environmentally friendly and less expensive than current technologies. Integrated gasification combined cycle (IGCC) power plants have been proposed as one of these systems. Utilising biofuels in future energy production will also be emphasised since this lowers substantially carbon dioxide emissions into the atmosphere due to the fact that biomass is a renewable form of energy. Combining advanced technology and biomass utilisation is for this reason something that should and will be encouraged. A. Ahlstrom Corporation of Finland and Sydkraft AB of Sweden have as one part of company strategies adopted this approach for the future. The companies have joined their resources in developing a biomass-based IGCC system with the gasification part based on pressurised circulating fluidized-bed technology. With this kind of technology electrical efficiency can be substantially increased compared to conventional power plants. As a first concrete step, a decision has been made to build a demonstration plant. This plant, located in Vaernamo, Sweden, has already been built and is now in commissioning and demonstration stage. The system comprises a fuel drying plant, a pressurised CFB gasifier with gas cooling and cleaning, a gas turbine, a waste heat recovery unit and a steam turbine. The plant is the first in the world where the integration of a pressurised gasifier with a gas turbine will be realised utilising a low calorific gas produced from biomass. The capacity of the Vaernamo plant is 6 MW of electricity and 9 MW of district heating. Technology development is in progress for design of plants of sizes from 20 to 120 MWe. The paper describes the Bioflow IGCC system, the Vaernamo demonstration plant and experiences from the commissioning and demonstration stages. (orig.)

  10. Lunar Water Resource Demonstration

    Science.gov (United States)

    Muscatello, Anthony C.

    2008-01-01

    In cooperation with the Canadian Space Agency, the Northern Centre for Advanced Technology, Inc., the Carnegie-Mellon University, JPL, and NEPTEC, NASA has undertaken the In-Situ Resource Utilization (ISRU) project called RESOLVE. This project is a ground demonstration of a system that would be sent to explore permanently shadowed polar lunar craters, drill into the regolith, determine what volatiles are present, and quantify them in addition to recovering oxygen by hydrogen reduction. The Lunar Prospector has determined these craters contain enhanced hydrogen concentrations averaging about 0.1%. If the hydrogen is in the form of water, the water concentration would be around 1%, which would translate into billions of tons of water on the Moon, a tremendous resource. The Lunar Water Resource Demonstration (LWRD) is a part of RESOLVE designed to capture lunar water and hydrogen and quantify them as a backup to gas chromatography analysis. This presentation will briefly review the design of LWRD and some of the results of testing the subsystem. RESOLVE is to be integrated with the Scarab rover from CMIJ and the whole system demonstrated on Mauna Kea on Hawaii in November 2008. The implications of lunar water for Mars exploration are two-fold: 1) RESOLVE and LWRD could be used in a similar fashion on Mars to locate and quantify water resources, and 2) electrolysis of lunar water could provide large amounts of liquid oxygen in LEO, leading to lower costs for travel to Mars, in addition to being very useful at lunar outposts.

  11. Waste and Disposal: Demonstration

    International Nuclear Information System (INIS)

    Neerdael, B.; Buyens, M.; De Bruyn, D.; Volckaert, G.

    2002-01-01

    Within the Belgian R and D programme on geological disposal, demonstration experiments have become increasingly important. In this contribution to the scientific report 2001, an overview is given of SCK-CEN's activities and achievements in the field of large-scale demonstration experiments. In 2001, main emphasis was on the PRACLAY project, which is a large-scale experiment to demonstrate the construction and the operation of a gallery for the disposal of HLW in a clay formation. The PRACLAY experiment will contribute to enhance understanding of water flow and mass transport in dense clay-based materials as well as to improve the design of the reference disposal concept. In the context of PRACLAY, a surface experiment (OPHELIE) has been developed to prepare and to complement PRACLAY-related experimental work in the HADES Underground Research Laboratory. In 2001, efforts were focussed on the operation of the OPHELIE mock-up. SCK-CEN also contributed to the SELFRAC roject which studies the self-healing of fractures in a clay formation

  12. Performance Demonstration Program Management Plan

    International Nuclear Information System (INIS)

    2005-01-01

    To demonstrate compliance with the Waste Isolation Pilot Plant (WIPP) waste characterization program, each testing and analytical facility performing waste characterization activities participates in the Performance Demonstration Program (PDP). The PDP serves as a quality control check against expected results and provides information about the quality of data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed by an independent organization to each of the facilities participating in the PDP. There are three elements within the PDP: analysis of simulated headspace gases, analysis of solids for Resource Conservation and Recovery Act (RCRA) constituents, and analysis for transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques. Because the analysis for TRU radionuclides using NDA techniques involves both the counting of drums and standard waste boxes, four PDP plans are required to describe the activities of the three PDP elements. In accordance with these PDP plans, the reviewing and approving authority for PDP results and for the overall program is the CBFO PDP Appointee. The CBFO PDP Appointee is responsible for ensuring the implementation of each of these plans by concurring with the designation of the Program Coordinator and by providing technical oversight and coordination for the program. The Program Coordinator will designate the PDP Manager, who will coordinate the three elements of the PDP. The purpose of this management plan is to identify how the requirements applicable to the PDP are implemented during the management and coordination of PDP activities. The other participants in the program (organizations that perform site implementation and activities under CBFO contracts or interoffice work orders) are not covered under this management plan. Those activities are governed by the organization's quality assurance (QA) program and procedures or as otherwise directed by CBFO.

  13. Comparison of five assays for detection of Clostridium difficile toxin.

    Science.gov (United States)

    Chapin, Kimberle C; Dickenson, Roberta A; Wu, Fongman; Andrea, Sarah B

    2011-07-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  14. Comparison of Five Assays for Detection of Clostridium difficile Toxin

    Science.gov (United States)

    Chapin, Kimberle C.; Dickenson, Roberta A.; Wu, Fongman; Andrea, Sarah B.

    2011-01-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. PMID:21704273

  15. Principles of validation of diagnostic assays for infectious diseases

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    Assay validation requires a series of inter-related processes. Assay validation is an experimental process: reagents and protocols are optimized by experimentation to detect the analyte with accuracy and precision. Assay validation is a relative process: its diagnostic sensitivity and diagnostic specificity are calculated relative to test results obtained from reference animal populations of known infection/exposure status. Assay validation is a conditional process: classification of animals in the target population as infected or uninfected is conditional upon how well the reference animal population used to validate the assay represents the target population; accurate predictions of the infection status of animals from test results (PV+ and PV-) are conditional upon the estimated prevalence of disease/infection in the target population. Assay validation is an incremental process: confidence in the validity of an assay increases over time when use confirms that it is robust as demonstrated by accurate and precise results; the assay may also achieve increasing levels of validity as it is upgraded and extended by adding reference populations of known infection status. Assay validation is a continuous process: the assay remains valid only insofar as it continues to provide accurate and precise results as proven through statistical verification. Therefore, the work required for validation of diagnostic assays for infectious diseases does not end with a time-limited series of experiments based on a few reference samples rather, to assure valid test results from an assay requires constant vigilance and maintenance of the assay, along with reassessment of its performance characteristics for each unique population of animals to which it is applied. (author)

  16. Demonstration of HITEX

    International Nuclear Information System (INIS)

    Morrison, H.D.; Woodall, K.B.

    1993-01-01

    A model reactor for HITEX successfully demonstrated the concept of high-temperature isotopic exchange in a closed loop simulating the conditions for fusion fuel cleanup. The catalyst of platinum on alumina pellets provided a surface area large enough to operate the reactor at 400 degrees celsius with flow rates up to 2 L/min. A 15-L tank containing a mixture of 4% CD 4 in H 2 was depleted in deuterium within 75 minutes down to 100 ppm HD above the natural concentration of HD in the make-up hydrogen stream. The application to tritium removal from tritiated impurities in a hydrogen stream will work as well or better

  17. Visual Electricity Demonstrator

    Science.gov (United States)

    Lincoln, James

    2017-09-01

    The Visual Electricity Demonstrator (VED) is a linear diode array that serves as a dynamic alternative to an ammeter. A string of 48 red light-emitting diodes (LEDs) blink one after another to create the illusion of a moving current. Having the current represented visually builds an intuitive and qualitative understanding about what is happening in a circuit. In this article, I describe several activities for this device and explain how using this technology in the classroom can enhance the understanding and appreciation of physics.

  18. Exploration Medical System Demonstration

    Science.gov (United States)

    Rubin, D. A.; Watkins, S. D.

    2014-01-01

    BACKGROUND: Exploration class missions will present significant new challenges and hazards to the health of the astronauts. Regardless of the intended destination, beyond low Earth orbit a greater degree of crew autonomy will be required to diagnose medical conditions, develop treatment plans, and implement procedures due to limited communications with ground-based personnel. SCOPE: The Exploration Medical System Demonstration (EMSD) project will act as a test bed on the International Space Station (ISS) to demonstrate to crew and ground personnel that an end-to-end medical system can assist clinician and non-clinician crew members in optimizing medical care delivery and data management during an exploration mission. Challenges facing exploration mission medical care include limited resources, inability to evacuate to Earth during many mission phases, and potential rendering of medical care by non-clinicians. This system demonstrates the integration of medical devices and informatics tools for managing evidence and decision making and can be designed to assist crewmembers in nominal, non-emergent situations and in emergent situations when they may be suffering from performance decrements due to environmental, physiological or other factors. PROJECT OBJECTIVES: The objectives of the EMSD project are to: a. Reduce or eliminate the time required of an on-orbit crew and ground personnel to access, transfer, and manipulate medical data. b. Demonstrate that the on-orbit crew has the ability to access medical data/information via an intuitive and crew-friendly solution to aid in the treatment of a medical condition. c. Develop a common data management framework that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all activities pertaining to crew health and life sciences. d. Ensure crew access to medical data during periods of restricted ground communication. e. Develop a common data management framework that

  19. Commercial incineration demonstration

    International Nuclear Information System (INIS)

    Vavruska, J.S.; Borduin, L.C.

    1982-01-01

    Low-level radioactive wastes (LLW) generated by nuclear utilities presently are shipped to commercial burial grounds for disposal. Increasing transportation and disposal costs have caused industry to consider incineration as a cost-effective means of volume reduction of combustible LLW. Repeated inquiries from the nuclear industry regarding the applicability of the Los Alamos controlled air incineration (CAI) design led the DOE to initiate a commercial demonstration program in FY-1980. Development studies and results in support of this program involving ion exchange resin incineration and fission/activation product distributions within the Los Alamos CAI are described

  20. Demonstration tokamak power plant

    International Nuclear Information System (INIS)

    Abdou, M.; Baker, C.; Brooks, J.; Ehst, D.; Mattas, R.; Smith, D.L.; DeFreece, D.; Morgan, G.D.; Trachsel, C.

    1983-01-01

    A conceptual design for a tokamak demonstration power plant (DEMO) was developed. A large part of the study focused on examining the key issues and identifying the R and D needs for: (1) current drive for steady-state operation, (2) impurity control and exhaust, (3) tritium breeding blanket, and (4) reactor configuration and maintenance. Impurity control and exhaust will not be covered in this paper but is discussed in another paper in these proceedings, entitled Key Issues of FED/INTOR Impurity Control System

  1. Smart Grid Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Craig [National Rural Electric Cooperative Association, Arlington, VA (United States); Carroll, Paul [National Rural Electric Cooperative Association, Arlington, VA (United States); Bell, Abigail [National Rural Electric Cooperative Association, Arlington, VA (United States)

    2015-03-11

    The National Rural Electric Cooperative Association (NRECA) organized the NRECA-U.S. Department of Energy (DOE) Smart Grid Demonstration Project (DE-OE0000222) to install and study a broad range of advanced smart grid technologies in a demonstration that spanned 23 electric cooperatives in 12 states. More than 205,444 pieces of electronic equipment and more than 100,000 minor items (bracket, labels, mounting hardware, fiber optic cable, etc.) were installed to upgrade and enhance the efficiency, reliability, and resiliency of the power networks at the participating co-ops. The objective of this project was to build a path for other electric utilities, and particularly electrical cooperatives, to adopt emerging smart grid technology when it can improve utility operations, thus advancing the co-ops’ familiarity and comfort with such technology. Specifically, the project executed multiple subprojects employing a range of emerging smart grid technologies to test their cost-effectiveness and, where the technology demonstrated value, provided case studies that will enable other electric utilities—particularly electric cooperatives— to use these technologies. NRECA structured the project according to the following three areas: Demonstration of smart grid technology; Advancement of standards to enable the interoperability of components; and Improvement of grid cyber security. We termed these three areas Technology Deployment Study, Interoperability, and Cyber Security. Although the deployment of technology and studying the demonstration projects at coops accounted for the largest portion of the project budget by far, we see our accomplishments in each of the areas as critical to advancing the smart grid. All project deliverables have been published. Technology Deployment Study: The deliverable was a set of 11 single-topic technical reports in areas related to the listed technologies. Each of these reports has already been submitted to DOE, distributed to co-ops, and

  2. Electrodynamic Dust Shield Demonstrator

    Science.gov (United States)

    Stankie, Charles G.

    2013-01-01

    The objective of the project was to design and manufacture a device to demonstrate a new technology developed by NASA's Electrostatics and Surface Physics Laboratory. The technology itself is a system which uses magnetic principles to remove regolith dust from its surface. This project was to create an enclosure that will be used to demonstrate the effectiveness of the invention to The Office of the Chief Technologist. ONE of the most important challenges of space exploration is actually caused by something very small and seemingly insignificant. Dust in space, most notably on the moon and Mars, has caused many unforeseen issues. Dirt and dust on Earth, while a nuisance, can be easily cleaned and kept at bay. However, there is considerably less weathering and erosion in space. As a result, the microscopic particles are extremely rough and abrasive. They are also electrostatically charged, so they cling to everything they make contact with. This was first noted to be a major problem during the Apollo missions. Dust would stick to the spacesuits, and could not be wiped off as predicted. Dust was brought back into the spacecraft, and was even inhaled by astronauts. This is a major health hazard. Atmospheric storms and other events can also cause dust to coat surfaces of spacecraft. This can cause abrasive damage to the craft. The coating can also reduce the effectiveness of thermal insulation and solar panels.' A group of engineers at Kennedy Space Center's Electrostatics and Surface Physics Laboratory have developed a new technology, called the Electrodynamic Dust Shield, to help alleviate these problems. It is based off of the electric curtain concept developed at NASA in 1967. "The EDS is an active dust mitigation technology that uses traveling electric fields to transport electrostatically charged dust particles along surfaces. To generate the traveling electric fields, the EDS consists of a multilayer dielectric coating with an embedded thin electrode grid

  3. Fuel Cell Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    Gerald Brun

    2006-09-15

    In an effort to promote clean energy projects and aid in the commercialization of new fuel cell technologies the Long Island Power Authority (LIPA) initiated a Fuel Cell Demonstration Program in 1999 with six month deployments of Proton Exchange Membrane (PEM) non-commercial Beta model systems at partnering sites throughout Long Island. These projects facilitated significant developments in the technology, providing operating experience that allowed the manufacturer to produce fuel cells that were half the size of the Beta units and suitable for outdoor installations. In 2001, LIPA embarked on a large-scale effort to identify and develop measures that could improve the reliability and performance of future fuel cell technologies for electric utility applications and the concept to establish a fuel cell farm (Farm) of 75 units was developed. By the end of October of 2001, 75 Lorax 2.0 fuel cells had been installed at the West Babylon substation on Long Island, making it the first fuel cell demonstration of its kind and size anywhere in the world at the time. Designed to help LIPA study the feasibility of using fuel cells to operate in parallel with LIPA's electric grid system, the Farm operated 120 fuel cells over its lifetime of over 3 years including 3 generations of Plug Power fuel cells (Lorax 2.0, Lorax 3.0, Lorax 4.5). Of these 120 fuel cells, 20 Lorax 3.0 units operated under this Award from June 2002 to September 2004. In parallel with the operation of the Farm, LIPA recruited government and commercial/industrial customers to demonstrate fuel cells as on-site distributed generation. From December 2002 to February 2005, 17 fuel cells were tested and monitored at various customer sites throughout Long Island. The 37 fuel cells operated under this Award produced a total of 712,635 kWh. As fuel cell technology became more mature, performance improvements included a 1% increase in system efficiency. Including equipment, design, fuel, maintenance

  4. Fusion-power demonstration

    International Nuclear Information System (INIS)

    Henning, C.D.; Logan, B.G.; Carlson, G.A.; Neef, W.S.; Moir, R.W.; Campbell, R.B.; Botwin, R.; Clarkson, I.R.; Carpenter, T.J.

    1983-01-01

    As a satellite to the MARS (Mirror Advanced Reactor Study) a smaller, near-term device has been scoped, called the FPD (Fusion Power Demonstration). Envisioned as the next logical step toward a power reactor, it would advance the mirror fusion program beyond MFTF-B and provide an intermediate step toward commercial fusion power. Breakeven net electric power capability would be the goal such that no net utility power would be required to sustain the operation. A phased implementation is envisioned, with a deuterium checkout first to verify the plasma systems before significant neutron activation has occurred. Major tritium-related facilities would be installed with the second phase to produce sufficient fusion power to supply the recirculating power to maintain the neutral beams, ECRH, magnets and other auxiliary equipment

  5. Spent fuel pyroprocessing demonstration

    International Nuclear Information System (INIS)

    McFarlane, L.F.; Lineberry, M.J.

    1995-01-01

    A major element of the shutdown of the US liquid metal reactor development program is managing the sodium-bonded spent metallic fuel from the Experimental Breeder Reactor-II to meet US environmental laws. Argonne National Laboratory has refurbished and equipped an existing hot cell facility for treating the spent fuel by a high-temperature electrochemical process commonly called pyroprocessing. Four products will be produced for storage and disposal. Two high-level waste forms will be produced and qualified for disposal of the fission and activation products. Uranium and transuranium alloys will be produced for storage pending a decision by the US Department of Energy on the fate of its plutonium and enriched uranium. Together these activities will demonstrate a unique electrochemical treatment technology for spent nuclear fuel. This technology potentially has significant economic and technical advantages over either conventional reprocessing or direct disposal as a high-level waste option

  6. Industrial demonstration trials

    International Nuclear Information System (INIS)

    Gelee, M.; Fabre, C.; Villepoix, R. de; Fra, J.; Le Foulgoc, L.; Morel, Y.; Querite, P.; Roques, R.

    1975-01-01

    Prototypes of the plant components, meeting the specifications set by the process and built by industrial firms in collaboration with the supervisor and the C.E.A., are subjected to trial runs on the UF 6 test bench of the Pierrelatte testing zone. These items of equipment (diffuser, compressor, exchanger) are placed in an industrial operation context very similar to that of an enrichment plant. Their performance is measured within a broad region around the working point and their reliability observed over periods up to several tens of thousands of hours. Between 1969 and 1973 six industrial demonstration test benches have been built, marking the stages in the technical preparation of the 1973 file on the basis of which the decision of building was taken by Eurodif [fr

  7. Fusion Power Demonstration III

    International Nuclear Information System (INIS)

    Lee, J.D.

    1985-07-01

    This is the third in the series of reports covering the Fusion Power Demonstration (FPD) design study. This volume considers the FPD-III configuration that incorporates an octopole end plug. As compared with the quadrupole end-plugged designs of FPD-I and FPD-II, this octopole configuration reduces the number of end cell magnets and shortens the minimum ignition length of the central cell. The end-cell plasma length is also reduced, which in turn reduces the size and cost of the end cell magnets and shielding. As a contiuation in the series of documents covering the FPD, this report does not stand alone as a design description of FPD-III. Design details of FPD-III subsystems that do not differ significantly from those of the FPD-II configuration are not duplicated in this report

  8. TPA device for demonstration

    International Nuclear Information System (INIS)

    1980-02-01

    The TPA (torus plasma for amature) is a small race-trac type device made by the technical service division to demonstrate basic properties of plasma such as electron temperature, conductivity, effect of helical field for toroidal drift, and shape of plasma in mirror and cusp magnetic field in linear section. The plasmas are produced by RF discharge (-500W) and/or DC discharge (-30 mA) within glass discharge tube. Where major radius is 50 cm, length of linear section is 50 cm, toroidal magnetic field is 200 gauss. The device has been designed to be compact with only 100 V power source (-3.2 KW for the case without helical field) and to be full automatic sequence of operation. (author)

  9. Fusion power demonstration

    International Nuclear Information System (INIS)

    Henning, C.D.; Logan, B.G.

    1983-01-01

    As a satellite to the MARS (Mirror Advanced Reactor Study) a smaller, near-term device has been scoped, called the FPD (Fusion Power Demonstration). Envisioned as the next logical step toward a power reactor, it would advance the mirror fusion program beyond MFTF-B and provide an intermediate step toward commercial fusion power. Breakeven net electric power capability would be the goal such that no net utility power would be required to sustain the operation. A phased implementation is envisioned, with a deuterium checkout first to verify the plasma systems before significant neutron activation has occurred. Major tritium-related facilities would be installed with the second phase to produce sufficient fusion power to supply the recirculating power to maintain the neutral beams, ECRH, magnets and other auxiliary equipment

  10. Dynamic wall demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Nakatsui, L.; Mayhew, W.

    1990-12-01

    The dynamic wall concept is a ventilation strategy that can be applied to a single family dwelling. With suitable construction, outside air can be admitted through the exterior walls of the house to the interior space to function as ventilation air. The construction and performance monitoring of a demonstration house built to test the dynamic wall concept in Sherwood Park, Alberta, is described. The project had the objectives of demonstrating and assessing the construction methods; determining the cost-effectiveness of the concept in Alberta; analyzing the operation of the dynamic wall system; and determining how other components and systems in the house interact with the dynamic wall. The exterior wall construction consisted of vinyl siding, spun-bonded polyolefin-backed (SBPO) rigid fiberglass sheathing, 38 mm by 89 mm framing, fiberglass batt insulation and 12.7 mm drywall. The mechanical system was designed to operate in the dynamic (negative pressure) mode, however flexibility was provided to allow operation in the static (balanced pressure) mode to permit monitoring of the walls as if they were in a conventional house. The house was monitored by an extensive computerized monitoring system. Dynamic wall operation was dependent on pressure and temperature differentials between indoor and outdoor as well as wind speed and direction. The degree of heat gain was found to be ca 74% of the indoor-outdoor temperature differential. Temperature of incoming dynamic air was significantly affected by solar radiation and measurement of indoor air pollutants found no significant levels. 4 refs., 34 figs., 11 tabs.

  11. MS transport assays for γ-aminobutyric acid transporters--an efficient alternative for radiometric assays.

    Science.gov (United States)

    Schmitt, Sebastian; Höfner, Georg; Wanner, Klaus T

    2014-08-05

    Transport assays for neurotransmitters based on radiolabeled substrates are widely spread and often indispensable in basic research and the drug development process, although the use of radioisotopes is inherently coupled to issues concerning radioactive waste and safety precautions. To overcome these disadvantages, we developed mass spectrometry (MS)-based transport assays for γ-aminobutyric acid (GABA), which is the major inhibitory neurotransmitter in the central nervous system (CNS). These "MS Transport Assays" provide all capabilities of [(3)H]GABA transport assays and therefore represent the first substitute for the latter. The performance of our approach is demonstrated for GAT1, the most important GABA transporter (GAT) subtype. As GABA is endogenously present in COS-7 cells employed as hGAT1 expression system, ((2)H6)GABA was used as a substrate to differentiate transported from endogenous GABA. To record transported ((2)H6)GABA, a highly sensitive, short, robust, and reliable HILIC-ESI-MS/MS quantification method using ((2)H2)GABA as an internal standard was developed and validated according to the Center for Drug Evaluation and Research (CDER) guidelines. Based on this LC-MS quantification, a setup to characterize hGAT1 mediated ((2)H6)GABA transport in a 96-well format was established, that enables automated processing and avoids any sample preparation. The K(m) value for ((2)H6)GABA determined for hGAT1 is in excellent agreement with results obtained from [(3)H]GABA uptake assays. In addition, the established assay format enables efficient determination of the inhibitory potency of GAT1 inhibitors, is capable of identifying those inhibitors transported as substrates, and furthermore allows characterization of efflux. The approach described here combines the strengths of LC-MS/MS with the high efficiency of transport assays based on radiolabeled substrates and is applicable to all GABA transporter subtypes.

  12. A Demonstration of Lusail

    KAUST Repository

    Mansour, Essam; Abdelaziz, Ibrahim; Ouzzani, Mourad; Aboulnaga, Ashraf; Kalnis, Panos

    2017-01-01

    There has been a proliferation of datasets available as interlinked RDF data accessible through SPARQL endpoints. This has led to the emergence of various applications in life science, distributed social networks, and Internet of Things that need to integrate data from multiple endpoints. We will demonstrate Lusail; a system that supports the need of emerging applications to access tens to hundreds of geo-distributed datasets. Lusail is a geo-distributed graph engine for querying linked RDF data. Lusail delivers outstanding performance using (i) a novel locality-aware query decomposition technique that minimizes the intermediate data to be accessed by the subqueries, and (ii) selectivityawareness and parallel query execution to reduce network latency and to increase parallelism. During the demo, the audience will be able to query actually deployed RDF endpoints as well as large synthetic and real benchmarks that we have deployed in the public cloud. The demo will also show that Lusail outperforms state-of-the-art systems by orders of magnitude in terms of scalability and response time.

  13. A Demonstration of Lusail

    KAUST Repository

    Mansour, Essam

    2017-05-10

    There has been a proliferation of datasets available as interlinked RDF data accessible through SPARQL endpoints. This has led to the emergence of various applications in life science, distributed social networks, and Internet of Things that need to integrate data from multiple endpoints. We will demonstrate Lusail; a system that supports the need of emerging applications to access tens to hundreds of geo-distributed datasets. Lusail is a geo-distributed graph engine for querying linked RDF data. Lusail delivers outstanding performance using (i) a novel locality-aware query decomposition technique that minimizes the intermediate data to be accessed by the subqueries, and (ii) selectivityawareness and parallel query execution to reduce network latency and to increase parallelism. During the demo, the audience will be able to query actually deployed RDF endpoints as well as large synthetic and real benchmarks that we have deployed in the public cloud. The demo will also show that Lusail outperforms state-of-the-art systems by orders of magnitude in terms of scalability and response time.

  14. Demonstration exercise 'Cavtat 09'

    International Nuclear Information System (INIS)

    Trut, D.

    2009-01-01

    The demonstration exercise is to show a terrorist attack in urban area resulting in a certain number of injured people. On 7th April 2009 a terrorist group HAL 9000 is in Cavtat and set up an explosive devices with chemical reagents in several spots with intention to activate them and cause great number of victims. On the same day, in area of the Cavtat Croatia Hotel, which is hosting the world CBMTS Congress, Cavtat Police Station notice several masked persons, in escapement. Hotel personnel alerted the County 112 Center about noticed devices placed by chlorine dioxide tanks, for water conditioning. Intervention police came to block entrance to this area and evacuate hotel's guests and congress members. An explosion and fire occurs from where the position of water-conditioning plant and chlorine dioxide tank. The 112 Center alarms fire-fighters for fight fire and decontamination action and HAZMAT Civil Support Team from Georgia (participated the congress). In the meantime, guests have been instructed not to leave their rooms and to hermetically close doors and windows with available material to keep away potential toxic fume. Decision makers form the County Protection and Rescue Headquarters monitors the situation till the end of alert for the population in the area of Cavtat.(author)

  15. Tidd PFBC demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Marrocco, M. [American Electric Power, Columbus, OH (United States)

    1997-12-31

    The Tidd project was one of the first joint government-industry ventures to be approved by the US Department of Energy (DOE) in its Clean Coal Technology Program. In March 1987, DOE signed an agreement with the Ohio Power Company, a subsidiary of American Electric Power, to refurbish the then-idle Tidd plant on the banks of the Ohio River with advanced pressurized fluidized bed technology. Testing ended after 49 months of operation, 100 individual tests, and the generation of more than 500,000 megawatt-hours of electricity. The demonstration plant has met its objectives. The project showed that more than 95 percent of sulfur dioxide pollutants could be removed inside the advanced boiler using the advanced combustion technology, giving future power plants an attractive alternative to expensive, add-on scrubber technology. In addition to its sulfur removal effectiveness, the plant`s sustained periods of steady-state operation boosted its availability significantly above design projections, heightening confidence that pressurized fluidized bed technology will be a reliable, baseload technology for future power plants. The technology also controlled the release of nitrogen oxides to levels well below the allowable limits set by federal air quality standards. It also produced a dry waste product that is much easier to handle than wastes from conventional power plants and will likely have commercial value when produced by future power plants.

  16. Identification of irradiated pepper with comet assay

    International Nuclear Information System (INIS)

    Prieto Miranda, Enrique Fco.; Moreno Alvarez, Damaris L.; Carro Palacio, Sandra; Iglesia Enriquez, Isora

    2007-01-01

    The treatment of foods with ionizing radiations is a technological process utilized in order to increase the hygienic quality and the storage time of the foods. Several methods of detection of irradiated foods have been recommended. The comet assay of DNA is one fast and economical technique for the qualitative identification of irradiated foods. The objective of the present paper was to identify with the comet assay technique the modifications of the DNA molecule of irradiated pepper storage at environment and refrigeration temperatures and different post-irradiation times for different absorbed dose values, (0.1, 0.3 and 0.5 kGy). It was demonstrated that for the high absorbed dose values was observed a greater break into fragments of the DNA molecule, which shows the application of this technique for the identification of irradiated foods. (author)

  17. Expert system technology for nondestructive waste assay

    International Nuclear Information System (INIS)

    Becker, G.K.; Determan, J.C.

    1998-01-01

    Nondestructive assay waste characterization data generated for use in the National TRU Program must be of known and demonstrable quality. Each measurement is required to receive an independent technical review by a qualified expert. An expert system prototype has been developed to automate waste NDA data review of a passive/active neutron drum counter system. The expert system is designed to yield a confidence rating regarding measurement validity. Expert system rules are derived from data in a process involving data clustering, fuzzy logic, and genetic algorithms. Expert system performance is assessed against confidence assignments elicited from waste NDA domain experts. Performance levels varied for the active, passive shielded, and passive system assay modes of the drum counter system, ranging from 78% to 94% correct classifications

  18. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  19. Kinesthetic Transverse Wave Demonstration

    Science.gov (United States)

    Pantidos, Panagiotis; Patapis, Stamatis

    2005-09-01

    This is a variation on the String and Sticky Tape demonstration "The Wave Game," suggested by Ron Edge. A group of students stand side by side, each one holding a card chest high with both hands. The teacher cues the first student to begin raising and lowering his card. When he starts lowering his card, the next student begins to raise his. As succeeding students move their cards up and down, a wave such as that shown in the figure is produced. To facilitate the process, students' motions were synchronized with the ticks of a metronome (without such synchronization it was nearly impossible to generate a satisfactory wave). Our waves typically had a frequency of about 1 Hz and a wavelength of around 3 m. We videotaped the activity so that the students could analyze the motions. The (17-year-old) students had not received any prior instruction regarding wave motion and did not know beforehand the nature of the exercise they were about to carry out. During the activity they were asked what a transverse wave is. Most of them quickly realized, without teacher input, that while the wave propagated horizontally, the only motion of the transmitting medium (them) was vertical. They located the equilibrium points of the oscillations, the crests and troughs of the waves, and identified the wavelength. The teacher defined for them the period of the oscillations of the motion of a card to be the total time for one cycle. The students measured this time and then several asserted that it was the same as the wave period. Knowing the length of the waves and the number of waves per second, the next step can easily be to find the wave speed.

  20. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Who and How: Comprehensive RNA-Based BodyfluID Assay to Provide Context to a Recovered DNA Profile

    Science.gov (United States)

    2015-08-25

    capillary electrophoresis (CE) and high resolution melt ( HRM ) assays 3 were developed and fully validated. The results of this study demonstrate...Multiplex High Resolution Melt ( HRM ) Assays ................................ 11  D. Developmental Validation of the CE and HRM Assays...Sequences (Top) and Primer Mix Composition (Bottom) for the Blood-Menstrual Blood HRM Assay

  2. The fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Lindhagen, Elin; Nygren, Peter; Larsson, Rolf

    2008-01-01

    The fluorometric microculture cytotoxicity assay (FMCA) is a nonclonogenic microplate-based cell viability assay used for measurement of the cytotoxic and/or cytostatic effect of different compounds in vitro. The assay is based on hydrolysis of the probe, fluorescein diacetate (FDA) by esterases in cells with intact plasma membranes. The assay is available as both a semiautomated 96-well plate setup and a 384-well plate version fully adaptable to robotics. Experimental plates are prepared with a small amount of drug solution and can be stored frozen. Cells are seeded on the plates and cell viability is evaluated after 72 h. The protocol described here is applicable both for cell lines and freshly prepared tumor cells from patients and is suitable both for screening in drug development and as a basis for a predictive test for individualization of anticancer drug therapy.

  3. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  4. Development of biotest assays using cell cultures from fish for the demonstration of lethal and sublethal damage to organisms due to environmental pollutants in water. Cellular biomarkers in fish cell cultures; Entwicklung von Biotestverfahren mit Zellkulturen aus Fischen zum Nachweis letaler und subletaler Schaeden von Organismen durch Umweltschadstoffe im Wasser. Zellulaere Biomarker in Fischzellkulturen

    Energy Technology Data Exchange (ETDEWEB)

    Braunbeck, T [Heidelberg Univ. (Germany). Zoologisches Inst. 1

    1994-06-01

    By means of isolated hepatocytes from rainbow trout (Oncorhyuchus myskiss), the reference substances 4-chloro-aniline, 2,4-dichlorophenol, dinitro-o-cresol and 4-nitrophenol, the pesticides atrazine and disulfotone, the ichthyotherapeutic malachite green, and landfill leachates were studied for their toxic effect. As new endpoints, ultrastructural and enzyme-biochemical parameters were established, which are suitable as a sensitive test system for acute, subacute, and sublethal pollutant effects. In comparison with conventional toxicity tests, ultrastructural and biochemical studies represent the currently most sensitive methods for demonstrating the (eco-) toxicological potential of pollutants. In all experiments, clear time-effect and dose-effect relationships could be made out. Isolated hepatocytes from the liver of rainbow trout reacted more sensitively than the permanent cell lines R1 and RTG-2 investigated in parallel. In cytotoxicity tests with the fibrocytic fish cell lines R1 and RTG-2 from the liver or gonad of rainbow trout, cytotoxicity data for various organic pollutants and organic and inorganic heavy metal compounds were acquired. The results form the basis of a concept for assessing the ecotoxicological potential of environmental pollutants by means of multi-stage cell tests, which is described in the paper. (orig./VHE) [Deutsch] Mit isolierten Hepatocyten aus Regenbogenforellen (oncorhyuchus myskiss) wurden die Referenzsubstanzen 4-Chloranilin, 2,4-Dichlorphenol, Dinitro-o-kresol und 4-Nitrophenol, die Pestizide Atrazin und Disulfoton, das Fischtherapeutikum Malachitgruen sowie Deponiesickerwaesser auf toxische Wirkungen untersucht. Als neuer Endpunkt wurden ultrastrukturelle und enzymbiochemische Parameter ermittelt, die sich als empfindliches Nachweissystem fuer akute, subakute und subletale Schadstoffwirkungen eignen. Im Vergleich mit konventionellen Toxizitaetstests stellen ultrastrukturelle und biochemischen Studien die derzeit empfindlichsten

  5. Battery operated preconcentration-assisted lateral flow assay.

    Science.gov (United States)

    Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon

    2017-07-11

    Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.

  6. Radioligand assay in reproductive biology

    International Nuclear Information System (INIS)

    Korenman, S.G.; Sherman, B.M.

    1975-01-01

    Radioligand assays have been developed for the principal reproductive steroids and peptide hormones. Specific binding reagents have included antibodies, plasma binders, and intracellular receptors. In each assay, problems of specificity, sensitivity, and nonspecific inhibitors were encountered. Many features of the endocrine physiology in childhood, during puberty, and in adulthood have been characterized. Hormonal evaluations of endocrine disorders of reproduction are characterized on the basis of their characteristic pathophysiologic alterations. (U.S.)

  7. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S.Y. [MagQu Co. Ltd., Sindian City, Taipei County 231, Taiwan (China); Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Lan, C.B.; Chen, C.H. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)], E-mail: phyfv001@scc.ntnu.edu.tw; Hong, Chin-Yih [Department of Mechanical Engineering, Nan-Kai University of Technology, Nantau County, Taiwan (China)], E-mail: cyhong@nkut.edu.tw; Yang, H.C. [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China)], E-mail: hcyang@phys.ntu.edu.tw; Lai, Y.K. [College of Life Sciences, National Tsing Hua University, Hsinchu City 300, Taiwan (China); Department of Bioresources, Da-Yeh University, Changhua 515, Taiwan (China); Lin, Y.H.; Teng, K.S. [Apex Biotechnology Co. Ltd., Hsinchu City 300, Taiwan (China)

    2009-10-15

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  8. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    International Nuclear Information System (INIS)

    Yang, S.Y.; Lan, C.B.; Chen, C.H.; Horng, H.E.; Hong, Chin-Yih; Yang, H.C.; Lai, Y.K.; Lin, Y.H.; Teng, K.S.

    2009-01-01

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  9. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  10. Test procedure for boxed waste assay system

    International Nuclear Information System (INIS)

    Wachter, J.

    1994-01-01

    This document, prepared by Los Alamos National Laboratory's NMT-4 group, details the test methodology and requirements for Acceptance/Qualification testing of a Boxed Waste Assay System (BWAS) designed and constructed by Pajarito Scientific Corporation. Testing of the BWAS at the Plutonium Facility (TA55) at Los Alamos National Laboratory will be performed to ascertain system adherence to procurement specification requirements. The test program shall include demonstration of conveyor handling capabilities, gamma ray energy analysis, and imaging passive/active neutron accuracy and sensitivity. Integral to these functions is the system's embedded operating and data reduction software

  11. Demonstration of a visual cell-based assay for screening glucose ...

    Indian Academy of Sciences (India)

    GLUT4 translocation is visualized by live cell imaging based on GFP fluorescence by employing a cooled charge-coupled device camera attached to a fluorescent microscope. This video imaging method and further quantitative analysis of GLUT4 on the cell membrane provide rapid and foolproof visual evidence that this ...

  12. Biobarcode assay for the oral anticoagulant acenocoumarol.

    Science.gov (United States)

    Broto, Marta; Salvador, J Pablo; Galve, Roger; Marco, M Pilar

    2018-02-01

    A novel approach for therapeutic drug monitoring of oral anticoagulants (OA) in clinical samples is reported, based on a NP-based biobarcode assay. The proposed strategy uses specific antibodies for acenocumarol (ACL) covalently bound to magnetic particles (pAb236-MP) and a bioconjugate competitor (hACL-BSA) linked to encoded polystyrene probes (hACL-BSA-ePSP) on a classical competitive immunochemical format. By using this scheme ACL can be detected in low nM range (LOD, 0.96 ± 0.26, N = 3, in buffer) even in complex samples such as serum or plasma (LOD 4 ± 1). The assay shows a high reproducibility (%CV 1.1 day-to-day) and is robust, as it is demonstrated by the fact that ACL can be quantified in complex biological samples with a very good accuracy (slope = 0.97 and R 2 = 0.91, of the linear regression obtained when analyzing spiked vs measured values). Moreover, we have demonstrated that the biobarcode approach has the potential to overcome one of the main challenges of the multiplexed diagnostic, which is the possibility to measure in a single run biomarker targets present at different concentration ranges. Thus, it has been proven that the signal and the detectability can be modulated by just modifying the oligonucleotide load of the encoded probes. This fact opens the door for combining in the same assay encoded probes with the necessary oligonucleotide load to achieve the detectability required for each biomarker target. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Information Integration Technology Demonstration (IITD)

    National Research Council Canada - National Science Library

    Loe, Richard

    2001-01-01

    The objectives of the Information Integration Technology Demonstration (IITD) were to investigate, design a software architecture and demonstrate a capability to display intelligence data from multiple disciplines...

  14. New low-viscosity overlay medium for viral plaque assays

    Directory of Open Access Journals (Sweden)

    Garten Wolfgang

    2006-08-01

    Full Text Available Abstract Background Plaque assays in cell culture monolayers under solid or semisolid overlay media are commonly used for quantification of viruses and antiviral substances. To overcome the pitfalls of known overlays, we tested suspensions of microcrystalline cellulose Avicel RC/CL™ as overlay media in the plaque and plaque-inhibition assay of influenza viruses. Results Significantly larger plaques were formed under Avicel-containing media, as compared to agar and methylcellulose (MC overlay media. The plaque size increased with decreasing Avicel concentration, but even very diluted Avicel overlays (0.3% ensured formation of localized plaques. Due to their low viscosity, Avicel overlays were easier to use than methylcellulose overlays, especially in the 96-well culture plates. Furthermore, Avicel overlay could be applied without prior removal of the virus inoculum thus facilitating the assay and reducing chances of cross-contamination. Using neuraminidase inhibitor oseltamivir carboxylate, we demonstrated applicability of the Avicel-based plaque reduction assay for testing of antiviral substances. Conclusion Plaque assay under Avicel-containing overlay media is easier, faster and more sensitive than assays under agar- and methylcellulose overlays. The assay can be readily performed in a 96-well plate format and seems particularly suitable for high-throughput virus titrations, serological studies and experiments on viral drug sensitivity. It may also facilitate work with highly pathogenic agents performed under hampered conditions of bio-safety labs.

  15. Complementing in vitro screening assays with in silico ...

    Science.gov (United States)

    High-throughput in vitro assays offer a rapid, cost-efficient means to screen thousands of chemicals across hundreds of pathway-based toxicity endpoints. However, one main concern involved with the use of in vitro assays is the erroneous omission of chemicals that are inactive under assay conditions but that can generate active metabolites under in vivo conditions. To address this potential issue, a case study will be presented to demonstrate the use of in silico tools to identify inactive parents with the ability to generate active metabolites. This case study used the results from an orthogonal assay designed to improve confidence in the identification of active chemicals tested across eighteen estrogen receptor (ER)-related in vitro assays by accounting for technological limitations inherent within each individual assay. From the 1,812 chemicals tested within the orthogonal assay, 1,398 were considered inactive. These inactive chemicals were analyzed using Chemaxon Metabolizer software to predict the first and second generation metabolites. From the nearly 1,400 inactive chemicals, over 2,200 first-generation (i.e., primary) metabolites and over 5,500 second-generation (i.e., secondary) metabolites were predicted. Nearly 70% of primary metabolites were immediately detoxified or converted to other metabolites, while over 70% of secondary metabolites remained stable. Among these predicted metabolites, those that are most likely to be produced and remain

  16. Evaluation of the Abbott ARCHITECT Toxo IgM assay.

    Science.gov (United States)

    Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin

    2009-07-01

    Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.

  17. Integrated bioassays in microfluidic devices: botulinum toxin assays.

    Science.gov (United States)

    Mangru, Shakuntala; Bentz, Bryan L; Davis, Timothy J; Desai, Nitin; Stabile, Paul J; Schmidt, James J; Millard, Charles B; Bavari, Sina; Kodukula, Krishna

    2005-12-01

    A microfluidic assay was developed for screening botulinum neurotoxin serotype A (BoNT-A) by using a fluorescent resonance energy transfer (FRET) assay. Molded silicone microdevices with integral valves, pumps, and reagent reservoirs were designed and fabricated. Electrical and pneumatic control hardware were constructed, and software was written to automate the assay protocol and data acquisition. Detection was accomplished by fluorescence microscopy. The system was validated with a peptide inhibitor, running 2 parallel assays, as a feasibility demonstration. The small footprint of each bioreactor cell (0.5 cm2) and scalable fluidic architecture enabled many parallel assays on a single chip. The chip is programmable to run a dilution series in each lane, generating concentration-response data for multiple inhibitors. The assay results showed good agreement with the corresponding experiments done at a macroscale level. Although the system has been developed for BoNT-A screening, a wide variety of assays can be performed on the microfluidic chip with little or no modification.

  18. Chromosome aberration assays in Allium

    Energy Technology Data Exchange (ETDEWEB)

    Grant, W.F.

    1982-01-01

    The common onion (Allium cepa) is an excellent plant for the assay of chromosome aberrations after chemical treatment. Other species of Allium (A. cepa var. proliferum, A. carinatum, A. fistulosum and A. sativum) have also been used but to a much lesser extent. Protocols have been given for using root tips from either bulbs or seeds of Allium cepa to study the cytological end-points, such as chromosome breaks and exchanges, which follow the testing of chemicals in somatic cells. It is considered that both mitotic and meiotic end-points should be used to a greater extent in assaying the cytogenetic effects of a chemical. From a literature survey, 148 chemicals are tabulated that have been assayed in 164 Allium tests for their clastogenic effect. Of the 164 assays which have been carried out, 75 are reported as giving a positive reaction, 49 positive and with a dose response, 1 positive and temperature-related, 9 borderline positive, and 30 negative; 76% of the chemicals gave a definite positive response. It is proposed that the Allium test be included among those tests routinely used for assessing chromosomal damage induced by chemicals.

  19. Monitoring cyclodextrin-polyviologen pseudopolyrotaxanes with the Bradford assay.

    Science.gov (United States)

    Belitsky, Jason M; Nelson, Alshakim; Stoddart, J Fraser

    2006-01-21

    Self-assembled multivalent pseudopolyrotaxanes, composed of lactoside-bearing cyclodextrin (CD) rings threaded on linear polyviologen polymers, have been introduced recently as flexible and dynamic neoglycoconjugates. In the course of this research, it was found that polyviologens are responsive to the Bradford assay, which is traditionally highly selective for proteins. The response of the pseudopolyrotaxanes to the Bradford assay was dependant on, and thus indicative of, the degree of threading of the CD rings onto the polyelectrolyte. The assay was then used to report on the threading and dethreading of native and lactoside-bearing alpha-CD rings onto and off of polyviologen chains, a phenomenon which demonstrates the utility of biochemical assays to address problems unique to supramolecular chemistry.

  20. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  1. Assay strategies and methods for phospholipases

    International Nuclear Information System (INIS)

    Reynolds, L.J.; Washburn, W.N.; Deems, R.A.; Dennis, E.A.

    1991-01-01

    Of the general considerations discussed, the two issues which are most important in choosing an assay are (1) what sensitivity is required to assay a particular enzyme and (2) whether the assay must be continuous. One can narrow the options further by considering substrate availability, enzyme specificity, assay convenience, or the presence of incompatible side reactions. In addition, the specific preference of a particular phospholipase for polar head group, micellar versus vesicular substrates, and anionic versus nonionic detergents may further restrict the options. Of the many assays described in this chapter, several have limited applicability or serious drawbacks and are not commonly employed. The most commonly used phospholipase assays are the radioactive TLC assay and the pH-stat assay. The TLC assay is probably the most accurate, sensitive assay available. These aspects often outweigh the disadvantages of being discontinuous, tedious, and expensive. The radioactive E. coli assay has become popular recently as an alternative to the TLC assay for the purification of the mammalian nonpancreatic phospholipases. The assay is less time consuming and less expensive than the TLC assay, but it is not appropriate when careful kinetics are required. Where less sensitivity is needed, or when a continuous assay is necessary, the pH-stat assay is often employed. With purified enzymes, when free thiol groups are not present, a spectrophotometric thiol assay can be used. This assay is ∼ as sensitive as the pH-stat assay but is more convenient and more reproducible, although the substrate is not available commercially. Despite the many assay choices available, the search continues for a convenient, generally applicable assay that is both sensitive and continuous

  2. Identification of Pou5f1, Sox2, and Nanog downstream target genes with statistical confidence by applying a novel algorithm to time course microarray and genome-wide chromatin immunoprecipitation data

    Directory of Open Access Journals (Sweden)

    Xin Li

    2008-06-01

    Full Text Available Abstract Background Target genes of a transcription factor (TF Pou5f1 (Oct3/4 or Oct4, which is essential for pluripotency maintenance and self-renewal of embryonic stem (ES cells, have previously been identified based on their response to Pou5f1 manipulation and occurrence of Chromatin-immunoprecipitation (ChIP-binding sites in promoters. However, many responding genes with binding sites may not be direct targets because response may be mediated by other genes and ChIP-binding site may not be functional in terms of transcription regulation. Results To reduce the number of false positives, we propose to separate responding genes into groups according to direction, magnitude, and time of response, and to apply the false discovery rate (FDR criterion to each group individually. Using this novel algorithm with stringent statistical criteria (FDR Pou5f1 suppression and published ChIP data, we identified 420 tentative target genes (TTGs for Pou5f1. The majority of TTGs (372 were down-regulated after Pou5f1 suppression, indicating that the Pou5f1 functions as an activator of gene expression when it binds to promoters. Interestingly, many activated genes are potent suppressors of transcription, which include polycomb genes, zinc finger TFs, chromatin remodeling factors, and suppressors of signaling. Similar analysis showed that Sox2 and Nanog also function mostly as transcription activators in cooperation with Pou5f1. Conclusion We have identified the most reliable sets of direct target genes for key pluripotency genes – Pou5f1, Sox2, and Nanog, and found that they predominantly function as activators of downstream gene expression. Thus, most genes related to cell differentiation are suppressed indirectly.

  3. Performance characteristics of the ARCHITECT anti-HCV assay.

    Science.gov (United States)

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  4. Buried Waste Integrated Demonstration lessons learned: 1993 technology demonstrations

    International Nuclear Information System (INIS)

    Kostelnik, K.M.; Owens, K.J.

    1994-01-01

    An integrated technology demonstration was conducted by the Buried Waste Integrated Demonstration (BWID) at the Idaho National Engineering Laboratory Cold Test Pit in the summer of 1993. This program and demonstration was sponsored by the US Department of Energy Office of Technology Development. The demonstration included six technologies representing a synergistic system for the characterization and retrieval of a buried hazardous waste site. The integrated technology demonstration proved very successful and a summary of the technical accomplishments is presented. Upon completion of the integrated technology demonstration, cognizant program personnel participated in a lessons learned exercise. This exercise was conducted at the Simplot Decision Support Center at Idaho State University and lessons learned activity captured additional information relative to the integration of technologies for demonstration purposes. This information will be used by BWID to enhance program planning and strengthen future technology demonstrations

  5. Nondestructive assay of sale materials

    International Nuclear Information System (INIS)

    Rodenburg, W.W.; Fleissner, J.G.

    1981-01-01

    This paper covers three primary areas: (1) reasons for performing nondestructive assay on SALE materials; (2) techniques used; and (3) discussion of investigators' revised results. The study shows that nondestructive calorimetric assay of plutonium offers a viable alternative to traditional wet chemical techniques. For these samples, the precision ranged from 0.4 to 0.6% with biases less than 0.2%. Thus, for those materials where sampling errors are the predominant source of uncertainty, this technique can provide improved accuracy and precision while saving time and money as well as reducing the amount of liquid wastes to be handled. In addition, high resolution gamma-ray spectroscopy measurements of solids can provide isotopic analysis data in a cost effective and timely manner. The timeliness of the method can be especially useful to the plant operator for production control and quality control measurements

  6. Comet Assay in Cancer Chemoprevention.

    Science.gov (United States)

    Santoro, Raffaela; Ferraiuolo, Maria; Morgano, Gian Paolo; Muti, Paola; Strano, Sabrina

    2016-01-01

    The comet assay can be useful in monitoring DNA damage in single cells caused by exposure to genotoxic agents, such as those causing air, water, and soil pollution (e.g., pesticides, dioxins, electromagnetic fields) and chemo- and radiotherapy in cancer patients, or in the assessment of genoprotective effects of chemopreventive molecules. Therefore, it has particular importance in the fields of pharmacology and toxicology, and in both environmental and human biomonitoring. It allows the detection of single strand breaks as well as double-strand breaks and can be used in both normal and cancer cells. Here we describe the alkali method for comet assay, which allows to detect both single- and double-strand DNA breaks.

  7. Radioreceptor assay for somatomedin A

    Energy Technology Data Exchange (ETDEWEB)

    Takano, K [Tokyo Women' s Medical Coll. (Japan)

    1975-04-01

    Measurement method of somatomedian A by radioreceptor assay using the human placenta membrane was described and discussed. Binding rate of /sup 125/I-somatomedin A to its receptors was studied under various conditions of time and temperature of the incubation, and pH of the system. The influence of somatomedin A, porcine insulin, and porcine calcitonin, on /sup 125/I-somatomedin A bound receptors was studied, and these hormones showed the competitive binding to somatomedin A receptors in some level. The specificity, recovery rate, and clinical applications of somatomedin A were also discussed. Radioreceptor assay for somatomedine A provided easier, faster, and more accurate measurements than conventional bioassay. This technique would be very useful to study somatomedin A receptor and functions of insulin.

  8. Results of in vitro chemosensitivity assays

    International Nuclear Information System (INIS)

    Tanigawa, Nobuhiko; Morimoto, Hideki; Akita, Toshiaki; Inoue, Hiroshi; Tanaka, Takeo.

    1986-01-01

    The authors reviewed their experiences to date with chemosensitivity testing of 629 tumors by human tumor clonogenic assay (HTCA) and of 199 tumors by scintillation assay (SA). HTCA and SA were both performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Overall, 60 % of specimens in HTCA and 58 % in SA produced significant growth in vitro. HTCA was 52 % (13/25) reliable for predicting in vivo sensitivity, and 95 % (36/38) reliable for in vivo resistance, whereas SA was 40 % (8/20) reliable for in vivo sensitivity and 88 % (21/24) for in vivo resistance. In vitro success rates were variable, depending on the tumor histology. In vitro growth of gastric cancer specimens was characteristically lower than that of colon cancer specimens (48 % and 60 % in HTCA, and 46 % and 68 % in SA, respectively). (p < 0.005). Optimal in vitro-in vivo drug concentrations and culture conditions are still being defined. Correlation studies of in vitro-in vivo responses of gastrointestinal cancers suggested that in vitro concentrations of 5-fluorouracil and mitomycin C used in this study were considerably higher than their optimal doses. Tumor cell heterogeneity poses significant problems in the clinical use of chemosensitivity assays. In this last study, we sought evidence of tumor heterogeneity by comparing chemosensitivity responses between : 1) different portions of a single tumor, 2) a primary and a metastatic biopsy taken from a patient on the same day, and 3) different metastases from a patient taken on the same day. The results demonstrated the presence of considerable heterogeneity of response to chemotherapy among different tumors from the same patient, and even within the same tumor. The reported discrepancies of in vitro and in vivo sensitivity may be due to such therapeutic heterogeneity among tumors. (J.P.N.)

  9. Assay of vitamin B12

    International Nuclear Information System (INIS)

    Tovey, K.C.; Carrick, D.T.

    1982-01-01

    A radioassay is described for vitamin B12 which involves denaturing serum protein binding proteins with alkali. In the denaturation step a dithiopolyol and cyanide are used and in the intrinsic factor assay step a vitamin B12 analogue such as cobinamide is used to bind with any remaining serum proteins. The invention also includes a kit in which the dithiopolyol is provided in admixture with the alkali. The dithiopolyol may be dithiothreitol or dithioerythritol. (author)

  10. Assay of ribulose bisphosphate carboxylase

    International Nuclear Information System (INIS)

    Pike, C.; Berry, J.

    1987-01-01

    Assays of ribulose bisphosphate carboxylase (rubisco) can be used to illustrate many properties of photosynthetic systems. Many different leaves have been assayed with this standard procedure. The tissue is ground with a mortar and pestle in extraction buffer. The supernatant after centrifugation is used as the source of enzyme. Buffer, RuBP, [ 14 C]-NaHCO 3 , and enzyme are combined in a scintillation vial; the reaction is run for 1 min at 30 0 . The acid-stable products are counted. Reproducibility in student experiments has been excellent. The assay data can be combined with analyses of leaf properties such as fresh and dry weight, chlorophyll and protein content, etc. Students have done projects such as the response of enzyme to temperature and to various inhibitors. They also report on the use of a transition state analog, carboxyarabinitol bisphosphate, to titrate the molar concentration of rubisco molecules (active sites) in an enzyme sample. Thus, using crude extracts the catalytic activity of a sample can be compared to the absolute quantity of enzyme or to the turnover number

  11. Integrated Ground Operations Demonstration Units

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of the AES Integrated Ground Operations Demonstration Units (IGODU) project is to demonstrate cost efficient cryogenic operations on a relevant...

  12. Cargo Data Management Demonstration System

    Science.gov (United States)

    1974-02-01

    Delays in receipt and creation of cargo documents are a problem in international trade. The work described demonstrates some of the advantages and capabilities of a computer-based cargo data management system. A demonstration system for data manageme...

  13. Teleoperation for learning by demonstration

    DEFF Research Database (Denmark)

    Kukliński, Kamil; Fischer, Kerstin; Marhenke, Ilka

    2014-01-01

    Learning by demonstration is a useful technique to augment a robot's behavioral inventory, and teleoperation allows lay users to demonstrate novel behaviors intuitively to the robot. In this paper, we compare two modes of teleoperation of an industrial robot, the demonstration by means of a data...... glove and by means of a control object (peg). Experiments with 16 lay users, performing assembly task on the Cranfield benchmark objects, show that the control peg leads to more success, more efficient demonstration and fewer errors....

  14. Helicopter detection and classification demonstrator

    NARCIS (Netherlands)

    Koersel, A.C. van

    2000-01-01

    A technology demonstrator that detects and classifies different helicopter types automatically, was developed at TNO-FEL. The demonstrator is based on a PC, which receives its acoustic input from an all-weather microphone. The demonstrator uses commercial off-the-shelf hardware to digitize the

  15. Kalman filter analysis of delayed neutron nondestructive assay measurements

    International Nuclear Information System (INIS)

    Aumeier, S. E.

    1998-01-01

    The ability to nondestructively determine the presence and quantity of fissile and fertile nuclei in various matrices is important in several nuclear applications including international and domestics safeguards, radioactive waste characterization and nuclear facility operations. Material irradiation followed by delayed neutron counting is a well known and useful nondestructive assay technique used to determine the fissile-effective content of assay samples. Previous studies have demonstrated the feasibility of using Kalman filters to unfold individual isotopic contributions to delayed neutron measurements resulting from the assay of mixes of uranium and plutonium isotopes. However, the studies in question used simulated measurement data and idealized parameters. We present the results of the Kalman filter analysis of several measurements of U/Pu mixes taken using Argonne National Laboratory's delayed neutron nondestructive assay device. The results demonstrate the use of Kalman filters as a signal processing tool to determine the fissile and fertile isotopic content of an assay sample from the aggregate delayed neutron response following neutron irradiation

  16. Pi overlapping ring systems contained in a homogeneous assay: a novel homogeneous assay for antigens

    Science.gov (United States)

    Kidwell, David A.

    1993-05-01

    A novel immunoassay, Pi overlapping ring systems contained in a homogeneous assay (PORSCHA), is described. This assay relies upon the change in fluorescent spectral properties that pyrene and its derivatives show with varying concentration. Because antibodies and other biomolecules can bind two molecules simultaneously, they can change the local concentration of the molecules that they bind. This concentration change may be detected spectrally as a change in the fluorescence emission wavelength of an appropriately labeled biomolecule. Several tests of PORSCHA have been performed which demonstrate this principle. For example: with streptavidin as the binding biomolecule and a biotin labeled pyrene derivative, the production of the excimer emitting at 470 nm is observed. Without the streptavidin present, only the monomer emitting at 378 and 390 nm is observed. The ratio of monomer to excimer provides the concentration of unlabeled biotin in the sample. Approximately 1 ng/mL of biotin may be detected with this system using a 50 (mu) l sample (2 X 10-16 moles biotin). The principles behind PORSCHA, the results with the streptavidin/biotin system are discussed and extensions of the PORSCHA concept to antibodies as the binding partner and DNA in homogeneous assays are suggested.

  17. A novel microculture kinetic assay (MiCK assay) for malignant cell growth and chemosensitivity.

    Science.gov (United States)

    Kravtsov, V D

    1994-01-01

    The THERMOmax microplate reader was adapted for monitoring the growth kinetics of human leukaemic OCI/AML-2 and mouse tumour J-774.1 cell lines in continuous culture. Fluid evaporation from wells, CO2 escape and contamination were prevented by hermetic sealing of the microcultures in wells of a 96-well microplate, thus enabling the cells to grow exponentially for 72 h under the conditions of the incubated microplate reader. For both OCI/AML-2 cells, which grow in suspension, and adherent J-774.1 cells, a linear correlation was demonstrated between the number of unstained cells seeded in a given microplate well and the optical density (OD) of that well. Therefore, the OD/time curve of the culture could be deemed to be its growth curve. By the use of the linear fit equation, the actual number of the cells in the wells was computable at any time point of the assay. In the chemosensitivity test, an inhibitory effect of ARA-C on the growth of the cells could be estimated by viewing of the growth curves plotted on the screen. The maximum kinetic rates (Vmax) of the curves in the control and the ARA-C-treated wells were compared, yielding a growth inhibition index (GII). Comparison of results of the kinetic chemosensitivity assay with those of a [3H]thymidine incorporation assay revealed that the novel assay is suitable for precise quantitation of the cell chemosensitivity, is more informative and has the added technical advantage of performance without recourse to radioactive or chemically hazardous substances.

  18. Radiosotopic assay and binder therefor

    International Nuclear Information System (INIS)

    Caston, J.D.; Kamen, B.A.

    1976-01-01

    A rapid and less costly radioisotopic assay for measuring the concentration of folate in blood serum is described. This procedure utilizes 3 H-pteroylmonoglutamate, unlabeled 5-methyltetrahydrofolic acid, and a partially purified folate binder, such as for example a folate binder extracted from hog kidney. The procedure involves radioisotopically relating the bound amounts of a labeled folate and a known folate at various concentrations of the known folate in a system containing a predetermined amount of the labeled folate, a predetermined amount of the binder factor for the folates, and a predetermined amount of defolated test serum. 16 claims, 8 drawing figures

  19. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.

    2013-01-01

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  20. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas

    2013-10-22

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  1. Demonstration of synthesis of beta-trace protein in different tissues of squirrel monkey

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, J E; Sandberg, M [Department of Neurology, University Hospital, S-221 85 Lund, Sweden

    1975-01-01

    The sites of synthesis of the low molwculat weight beta-trace protein, present in a seven times higher concentration in normal human CSF than in normal human serum, have been studied by means of a radioactive immunoprecipitation method. Adult squirrel monkey tissue were cultured in Eagle's minium essential medium in the presence of /sup 14/C-labelled valine, threonine and leucine for 24 hours. Synthesis could be demonstrated in cultures of white CNS matter, whereas cultures of grey CNS matter, peripheral nerve, skeletal muscle, kidney and ovary did not show any signs of synthesis. Some cultures of spinal cord, basal ganglia, genital organs except ovary, and liver showed a probable synthesis of beta-trace protein. By means of autoradiography, the synthesis of beta-trace protein in white CNS matter could be confirmed.

  2. Demonstration of synthesis of beta-trace protein in different tissues of squirrel monkey

    International Nuclear Information System (INIS)

    Olsson, J.-E.; Sandberg, M.

    1975-01-01

    The sites of synthesis of the low molwculat weight beta-trace protein, present in a seven times higher concentration in normal human CSF than in normal human serum, have been studied by means of a radioactive immunoprecipitation method. Adult squirrel monkey tissue were cultured in Eagle's minium essential medium in the presence of 14 C-labelled valine, threonine and leucine for 24 hours. Synthesis could be demonstrated in cultures of white CNS matter, whereas cultures of grey CNS matter, peripheral nerve, skeletal muscle, kidney and ovary did not show any signs of synthesis. Some cultures of spinal cord, basal ganglia, genital organs except ovary, and liver showed a probable synthesis of beta-trace protein. By means of autoradiography, the synthesis of beta-trace protein in white CNS matter could be confirmed. (author)

  3. Antioxidants and the Comet assay.

    Science.gov (United States)

    Cemeli, Eduardo; Baumgartner, Adolf; Anderson, Diana

    2009-01-01

    It is widely accepted that antioxidants, either endogenous or from the diet, play a key role in preserving health. They are able to quench radical species generated in situations of oxidative stress, either triggered by pathologies or xenobiotics, and they protect the integrity of DNA from genotoxicants. Nevertheless, there are still many compounds with unclear or unidentified prooxidant/antioxidant activities. This is of concern since there is an increase in the number of compounds synthesized or extracted from vegetables to which humans might be exposed. Despite the well-established protective effects of fruit and vegetables, the antioxidant(s) responsible have not all been clearly identified. There might also be alternative mechanisms contributing to the protective effects for which a comprehensive description is lacking. In the last two decades, the Comet assay has been extensively used for the investigation of the effects of antioxidants and many reports can be found in the literature. The Comet assay, a relatively fast, simple, and sensitive technique for the analysis of DNA damage in all cell types, has been applied for the screening of chemicals, biomonitoring and intervention studies. In the present review, several of the most well-known antioxidants are considered. These include: catalase, superoxide dismutase, glutathione peroxidase, selenium, iron chelators, melatonin, melanin, vitamins (A, B, C and E), carotenes, flavonoids, isoflavones, tea polyphenols, wine polyphenols and synthetic antioxidants. Investigations showing beneficial as well as non-beneficial properties of the antioxidants selected, either at the in vitro, ex vivo or in vivo level are discussed.

  4. Rotor assembly and assay method

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1993-09-07

    A rotor assembly for carrying out an assay includes a rotor body which is rotatable about an axis of rotation, and has a central chamber and first, second, third, fourth, fifth, and sixth chambers which are in communication with and radiate from the central chamber. The rotor assembly further includes a shuttle which is movable through the central chamber and insertable into any of the chambers, the shuttle including a reaction cup carrying an immobilized antigen or an antibody for transport among the chambers. A method for carrying out an assay using the rotor assembly includes moving the reaction cup among the six chambers by passing the cup through the central chamber between centrifugation steps in order to perform the steps of: separating plasma from blood cells, binding plasma antibody or antigen, washing, drying, binding enzyme conjugate, reacting with enzyme substrate and optically comparing the resulting reaction product with unreacted enzyme substrate solution. The movement of the reaction cup can be provided by attaching a magnet to the reaction cup and supplying a moving magnetic field to the rotor. 34 figures.

  5. Optics Demonstrations Using Cylindrical Lenses

    Science.gov (United States)

    Ivanov, Dragia; Nikolov, Stefan

    2015-01-01

    In this paper we consider the main properties of cylindrical lenses and propose several demonstrational experiments that can be performed with them. Specifically we use simple glasses full of water to demonstrate some basic geometrical optics principles and phenomena. We also present some less standard experiments that can be performed with such…

  6. A Comprehensive General Chemistry Demonstration

    Science.gov (United States)

    Sweeder, Ryan D.; Jeffery, Kathleen A.

    2013-01-01

    This article describes the use of a comprehensive demonstration suitable for a high school or first-year undergraduate introductory chemistry class. The demonstration involves placing a burning candle in a container adjacent to a beaker containing a basic solution with indicator. After adding a lid, the candle will extinguish and the produced…

  7. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  8. Multicentre comparison of a diagnostic assay

    DEFF Research Database (Denmark)

    Waters, Patrick; Reindl, Markus; Saiz, Albert

    2016-01-01

    ) assays in neuromyelitis optica spectrum disorders (NMOSD). METHODS: Coded samples from patients with neuromyelitis optica (NMO) or NMOSD (101) and controls (92) were tested at 15 European diagnostic centres using 21 assays including live (n=3) or fixed cell-based assays (n=10), flow cytometry (n=4...

  9. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  10. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  11. Duplex recombinase polymerase amplification assays incorporating competitive internal controls for bacterial meningitis detection.

    Science.gov (United States)

    Higgins, Owen; Clancy, Eoin; Forrest, Matthew S; Piepenburg, Olaf; Cormican, Martin; Boo, Teck Wee; O'Sullivan, Nicola; McGuinness, Claire; Cafferty, Deirdre; Cunney, Robert; Smith, Terry J

    2018-04-01

    Recombinase polymerase amplification (RPA) is an isothermal nucleic acid amplification technology that provides rapid and robust infectious disease pathogen detection, ideal for point-of-care (POC) diagnostics in disease-prevalent low-resource countries. We have developed and evaluated three duplex RPA assays incorporating competitive internal controls for the detection of leading bacterial meningitis pathogens. Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae singleplex RPA assays were initially developed and evaluated, demonstrating 100% specificity with limits of detection of 4.1, 8.5 and 3.9 genome copies per reaction, respectively. Each assay was further developed into internally controlled duplex RPA assays via the incorporation of internal amplification control templates. Clinical performance of each internally controlled duplex RPA assay was evaluated by testing 64 archived PCR-positive clinical samples. Compared to real-time PCR, all duplex RPA assays demonstrated 100% diagnostic specificity, with diagnostic sensitivities of 100%, 86.3% and 100% for the S. pneumoniae, N. meningitidis and H. influenzae assays, respectively. This study details the first report of internally controlled duplex RPA assays for the detection of bacterial meningitis pathogens: S. pneumoniae, N. meningitidis and H. influenzae. We have successfully demonstrated the clinical diagnostic utility of each duplex RPA assay, introducing effective diagnostic technology for POC bacterial meningitis identification in disease-prevalent developing countries. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Application of statistical process control to qualitative molecular diagnostic assays

    LENUS (Irish Health Repository)

    O'Brien, Cathal P.

    2014-11-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  13. Optimization of protein samples for NMR using thermal shift assays

    International Nuclear Information System (INIS)

    Kozak, Sandra; Lercher, Lukas; Karanth, Megha N.; Meijers, Rob; Carlomagno, Teresa; Boivin, Stephane

    2016-01-01

    Maintaining a stable fold for recombinant proteins is challenging, especially when working with highly purified and concentrated samples at temperatures >20 °C. Therefore, it is worthwhile to screen for different buffer components that can stabilize protein samples. Thermal shift assays or ThermoFluor"® provide a high-throughput screening method to assess the thermal stability of a sample under several conditions simultaneously. Here, we describe a thermal shift assay that is designed to optimize conditions for nuclear magnetic resonance studies, which typically require stable samples at high concentration and ambient (or higher) temperature. We demonstrate that for two challenging proteins, the multicomponent screen helped to identify ingredients that increased protein stability, leading to clear improvements in the quality of the spectra. Thermal shift assays provide an economic and time-efficient method to find optimal conditions for NMR structural studies.

  14. Optimization of protein samples for NMR using thermal shift assays

    Energy Technology Data Exchange (ETDEWEB)

    Kozak, Sandra [European Molecular Biology Laboratory (EMBL), Hamburg Outstation, SPC Facility (Germany); Lercher, Lukas; Karanth, Megha N. [European Molecular Biology Laboratory (EMBL), SCB Unit (Germany); Meijers, Rob [European Molecular Biology Laboratory (EMBL), Hamburg Outstation, SPC Facility (Germany); Carlomagno, Teresa, E-mail: teresa.carlomagno@oci.uni-hannover.de [European Molecular Biology Laboratory (EMBL), SCB Unit (Germany); Boivin, Stephane, E-mail: sboivin77@hotmail.com, E-mail: s.boivin@embl-hamburg.de [European Molecular Biology Laboratory (EMBL), Hamburg Outstation, SPC Facility (Germany)

    2016-04-15

    Maintaining a stable fold for recombinant proteins is challenging, especially when working with highly purified and concentrated samples at temperatures >20 °C. Therefore, it is worthwhile to screen for different buffer components that can stabilize protein samples. Thermal shift assays or ThermoFluor{sup ®} provide a high-throughput screening method to assess the thermal stability of a sample under several conditions simultaneously. Here, we describe a thermal shift assay that is designed to optimize conditions for nuclear magnetic resonance studies, which typically require stable samples at high concentration and ambient (or higher) temperature. We demonstrate that for two challenging proteins, the multicomponent screen helped to identify ingredients that increased protein stability, leading to clear improvements in the quality of the spectra. Thermal shift assays provide an economic and time-efficient method to find optimal conditions for NMR structural studies.

  15. Application of statistical process control to qualitative molecular diagnostic assays.

    Science.gov (United States)

    O'Brien, Cathal P; Finn, Stephen P

    2014-01-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  16. Specificity of B-type natriuretic peptide assays

    DEFF Research Database (Denmark)

    Saenger, Amy K.; Rodriguez-Fraga, Olaia; Ler, Ranka

    2017-01-01

    BACKGROUND: B-type natriuretic peptides (BNPs) are used clinically to diagnose and monitor heart failure and are present in the circulation as multiple proBNP-derived fragments. We investigated the specificity of BNP immunoassays with glycosylated and nonglycosylated BNP, N-terminal proBNP (NT......-proBNP), and proBNP peptides to probe the cross-reactivity of each assay. METHODS: Nine B-type natriuretic peptides were studied, including synthetic and recombinant BNP (Shionogi, Scios, Mayo), human and synthetic glycosylated and nonglycosylated NT-proBNP (HyTest, Roche Diagnostics), and human glycosylated......-Rad, Goetze] were evaluated. Specificity was assessed by calculating the recovery between baseline and peptide-spiked human plasma pools at target concentrations of 100 ng/L BNP, 300 ng/L proBNP, or 450 ng/L NT-proBNP. All assays were performed in duplicate. RESULTS: BNP and NT-proBNP assays demonstrated...

  17. Bluetongue virus: comparative evaluation of enzyme-linked immunosorbent assay, immunodiffusion, and serum neutralization for detection of viral antibodies.

    OpenAIRE

    Poli, G; Stott, J; Liu, Y S; Manning, J S

    1982-01-01

    Comparative studies on the detection of bovine serum immunoglobulin G antibodies to bluetongue virus with an enzyme-linked immunosorbent assay, an immunodiffusion method, and a serum neutralization assay demonstrated complete concordance between the enzyme-linked immunosorbent assay and the serum neutralization assay results. However, the immunodiffusion method failed to detect bluetongue virus antibody in a substantial number of sera found to possess bluetongue virus immunoglobulin G with th...

  18. Offsite demonstrations for MWLID technologies

    International Nuclear Information System (INIS)

    Williams, C.; Gruebel, R.

    1995-01-01

    The goal of the Offsite Demonstration Project for Mixed Waste Landfill Integrated Demonstration (MWLID)-developed environmental site characterization and remediation technologies is to facilitate the transfer, use, and commercialization of these technologies to the public and private sector. The meet this goal, the project identified environmental restoration needs of mixed waste and/or hazardous waste landfill owners (Native American, municipal, DOE, and DoD); documenting potential demonstration sites and the contaminants present at each site; assessing the environmental regulations that would effect demonstration activities; and evaluating site suitability for demonstrating MWLID technologies at the tribal and municipal sites identified. Eighteen landfill sites within a 40.2-km radius of Sandia National Laboratories are listed on the CERCLIS Site/Event Listing for the state of New Mexico. Seventeen are not located within DOE or DoD facilities and are potential offsite MWLID technology demonstration sites. Two of the seventeen CERCLIS sites, one on Native American land and one on municipal land, were evaluated and identified as potential candidates for off-site demonstrations of MWLID-developed technologies. Contaminants potentially present on site include chromium waste, household/commercial hazardous waste, volatile organic compounds, and petroleum products. MWLID characterization technologies applicable to these sites include Magnetometer Towed Array, Cross-borehole Electromagnetic Imaging, SitePlanner trademark/PLUME, Hybrid Directional Drilling, Seamist trademark/Vadose Zone Monitoring, Stripping Analyses, and x-ray Fluorescence Spectroscopy for Heavy Metals

  19. Notional Airspace Operations Demonstration Plan

    Science.gov (United States)

    Trongale, Nicholas A.

    2006-01-01

    The airspace operations demonstration (AOD) is intended to show that the Access 5 Step 1 functional requirements can be met. The demonstration will occur in two phases. The initial on-range phase will be carried out in restricted airspace to demonstrate the cooperative collision avoidance (CCA) functional requirements and to provide risk-reduction for the AOD by allowing the test team to rehearse some elements of the demonstration mission. The CCA system to be used in these flights is based on Automatic Dependent Surveillance-Broadcast (ADS-B) which is a commercially-available system by which airplanes constantly broadcast their current position and altitude to other aircraft and ground resources over a dedicated radio datalink. The final phase will occur in the national airspace (NAS) and will be the formal demonstration of the remainder of the proposed functional requirements. The general objectives of the AOD are as follows: (1) Demonstrate that the UAS can aviate in the NAS (2) Demonstrate that the UAS can navigate in the NAS (3) Demonstrate that the UAS can communicate with the NAS (4) Demonstrate that the UAS can perform selected collision avoidance functions in the NAS (5) Demonstrate that the UAS can evaluate and avoid weather conflicts in the NAS (6) Demonstrate that the UAS can provide adequate command and control in the NAS In addition to the stated objectives, there are a number of goals for the flight demonstration. The demo can be accomplished successfully without achieving these goals, but these goals are to be used as a guideline for preparing for the mission. The goals are: (1) Mission duration of at least 24 hours (2) Loiter over heavy traffic to evaluate the data block issue identified during the Access 5 Airspace Operations Simulations (3) Document the contingency management process and lessons learned (4) Document the coordination process for Ground Control Stations (GCS) handoff (5) Document lessons learned regarding the process of flying in

  20. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  1. Non destructive assay (NDA) techniques

    International Nuclear Information System (INIS)

    Mafra Guidicini, Olga; Llacer, Carlos D.; Rojo, Marcelo

    2001-01-01

    In the IAEA Safeguards System the basic verification method used is nuclear material accountancy, with containment and surveillance as important complementary measures. If nuclear material accountancy is to be effective, IAEA inspectors have to make independent measurements to verify declared material quantities. Most of the equipment available to the inspectors is designed to measure gamma rays and/or neutrons emitted by various nuclear materials. Equipment is also available to measure the gross weight of an item containing nuclear material. These types of measurement techniques are generally grouped under the title of nondestructive assay (NDA). The paper describes the NDA techniques and instruments used to verify the total amount of nuclear material held at a nuclear facility. (author)

  2. Demonstration of Cauchy: Understanding Algebraic

    Directory of Open Access Journals (Sweden)

    T.L. Costa

    2012-11-01

    Full Text Available ABSTRACT: In this study we present some considerations about the End of Course Work undergraduate Full Degree in Mathematics / UFMT, drafted in 2011, and by taking title "A story about Cauchy and Euler's theorem on polyhedra" that gave birth to our research project Master of Education, begun in 2012, on the approaches of Euler's theorem on polyhedra in mathematics textbooks. At work in 2011 presented some considerations about the history of Euler's theorem for polyhedra which focus the demonstration presented by Cauchy (1789-1857, who tries to generalize it, relying on assumptions not observable in Euclidean geometry. Therefore, we seek the accessible literature on the history of mathematics; relate some aspects of the demonstration Cauchy with historical events on the development of mathematics in the nineteenth century, which allowed the acceptance of such a demonstration by mathematicians of his time.Keywords: History of Mathematics. Euler's Theorem on Polyhedra. Demonstration of Cauchy.

  3. CT Demonstration of Caput Medusae

    Science.gov (United States)

    Weber, Edward C.; Vilensky, Joel A.

    2009-01-01

    Maximum intensity and volume rendered CT displays of caput medusae are provided to demonstrate both the anatomy and physiology of this portosystemic shunt associated with portal hypertension. (Contains 2 figures.)

  4. Fuel Gas Demonstration Plant Program. Volume I. Demonstration plant

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    The objective of this project is for Babcock Contractors Inc. (BCI) to provide process designs, and gasifier retort design for a fuel gas demonstration plant for Erie Mining Company at Hoyt Lake, Minnesota. The fuel gas produced will be used to supplement natural gas and fuel oil for iron ore pellet induration. The fuel gas demonstration plant will consist of five stirred, two-stage fixed-bed gasifier retorts capable of handling caking and non-caking coals, and provisions for the installation of a sixth retort. The process and unit design has been based on operation with caking coals; however, the retorts have been designed for easy conversion to handle non-caking coals. The demonstration unit has been designed to provide for expansion to a commercial plant (described in Commercial Plant Package) in an economical manner.

  5. Development and validation of receptor occupancy pharmacodynamic assays used in the clinical development of the monoclonal antibody vedolizumab.

    Science.gov (United States)

    Wyant, Tim; Estevam, Jose; Yang, Lili; Rosario, Maria

    2016-03-01

    Vedolizumab is a monoclonal antibody approved for use in ulcerative colitis and Crohn's disease. By specifically binding to α4 β7 integrin, vedolizumab prevents trafficking of lymphocytes to the gut, thereby interfering with disease pathology. During the clinical development program, the pharmacodynamic effect of vedolizumab was evaluated by 2 flow cytometry receptor occupancy assays: act-1 (ACT-1) and mucosal addressin cell adhesion molecule-1 (MAdCAM-1). Here we describe the development and validation of these assays. The ACT-1 assay is a receptor occupancy free-site assay that uses a monoclonal antibody with the same binding epitope as vedolizumab to detect free (unbound) sites on α4 β7 integrin. The MAdCAM-1 assay used a soluble version of the natural ligand for α4 β7 integrin to detect free sites. The assays were validated using a fit-for-purpose approach throughout the clinical development of vedolizumab. Both the ACT-1 assay and the MAdCAM-1 assay demonstrated acceptable reproducibility and repeatability. The assays were sufficiently stable to allow for clinical use. During clinical testing the assays demonstrated that vedolizumab was able to saturate peripheral cells at all doses tested. Two pharmacodynamic receptor occupancy assays were developed and validated to assess the effect of vedolizumab on peripheral blood cells. The results of these assays demonstrated the practical use of flow cytometry to examine pharmacodynamic response in clinical trials. © 2015 International Clinical Cytometry Society.

  6. A highly scalable peptide-based assay system for proteomics.

    Directory of Open Access Journals (Sweden)

    Igor A Kozlov

    Full Text Available We report a scalable and cost-effective technology for generating and screening high-complexity customizable peptide sets. The peptides are made as peptide-cDNA fusions by in vitro transcription/translation from pools of DNA templates generated by microarray-based synthesis. This approach enables large custom sets of peptides to be designed in silico, manufactured cost-effectively in parallel, and assayed efficiently in a multiplexed fashion. The utility of our peptide-cDNA fusion pools was demonstrated in two activity-based assays designed to discover protease and kinase substrates. In the protease assay, cleaved peptide substrates were separated from uncleaved and identified by digital sequencing of their cognate cDNAs. We screened the 3,011 amino acid HCV proteome for susceptibility to cleavage by the HCV NS3/4A protease and identified all 3 known trans cleavage sites with high specificity. In the kinase assay, peptide substrates phosphorylated by tyrosine kinases were captured and identified by sequencing of their cDNAs. We screened a pool of 3,243 peptides against Abl kinase and showed that phosphorylation events detected were specific and consistent with the known substrate preferences of Abl kinase. Our approach is scalable and adaptable to other protein-based assays.

  7. Widespread nanoparticle-assay interference: implications for nanotoxicity testing.

    Science.gov (United States)

    Ong, Kimberly J; MacCormack, Tyson J; Clark, Rhett J; Ede, James D; Ortega, Van A; Felix, Lindsey C; Dang, Michael K M; Ma, Guibin; Fenniri, Hicham; Veinot, Jonathan G C; Goss, Greg G

    2014-01-01

    The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1) nanoparticle intrinsic fluorescence/absorbance, 2) interactions between nanoparticles and assay components, and 3) the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments.

  8. Widespread nanoparticle-assay interference: implications for nanotoxicity testing.

    Directory of Open Access Journals (Sweden)

    Kimberly J Ong

    Full Text Available The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1 nanoparticle intrinsic fluorescence/absorbance, 2 interactions between nanoparticles and assay components, and 3 the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments.

  9. The use of comet assay in plant toxicology: recent advances

    Directory of Open Access Journals (Sweden)

    Conceição LV Santos

    2015-06-01

    Full Text Available The systematic study of genotoxicity in plants induced by contaminants and other stress agents has been hindered to date by the lack of reliable and robust biomarkers. The comet assay is a versatile and sensitive method for the evaluation of DNA damages and DNA repair capacity at single-cell level. Due to its simplicity and sensitivity, and the small number of cells required to obtain robust results, the use of plant comet assay has drastically increased in the last decade. For years its use was restricted to a few model species, e.g. Allium cepa, Nicotiana tabacum, Vicia faba, or Arabidopsis thaliana but this number largely increased in the last years. Plant comet assay has been used to study the genotoxic impact of radiation, chemicals including pesticides, phytocompounds, heavy metals, nanoparticles or contaminated complex matrices. Here we will review the most recent data on the use of this technique as a standard approach for studying the genotoxic effects of different stress conditions on plants. Also, we will discuss the integration of information provided by the comet assay with other DNA-damage indicators, and with cellular responses including oxidative stress, cell division or cell death. Finally, we will focus on putative relations between transcripts related with DNA damage pathways, DNA replication and repair, oxidative stress and cell cycle progression that have been identified in plant cells with comet assays demonstrating DNA damage.

  10. Drosophila comet assay: insights, uses, and future perspectives

    Science.gov (United States)

    Gaivão, Isabel; Sierra, L. María

    2014-01-01

    The comet assay, a very useful tool in genotoxicity and DNA repair testing, is being applied to Drosophila melanogaster since around 15 years ago, by several research groups. This organism is a valuable model for all kind of processes related to human health, including DNA damage response. The assay has been performed mainly in vivo using different larvae cell types (from brain, midgut, hemolymph, and imaginal disk), but also in vitro with the S2 cell line. Since its first application, it has been used to analyze the genotoxicity and action mechanisms of different chemicals, demonstrating good sensitivity and proving its usefulness. Moreover, it is the only assay that can be used to analyze DNA repair in somatic cells in vivo, comparing the effects of chemicals in different repair strains, and to quantitate repair activities in vitro. Additionally, the comet assay in Drosophila, in vivo and in vitro, has been applied to study the influence of protein overexpression on genome integrity and degradation. Although the assay is well established, it could benefit from some research to determine optimal experimental design to standardize it, and then to allow comparisons among laboratories independently of the chosen cell type. PMID:25221574

  11. The use of comet assay in plant toxicology: recent advances

    Science.gov (United States)

    Santos, Conceição L. V.; Pourrut, Bertrand; Ferreira de Oliveira, José M. P.

    2015-01-01

    The systematic study of genotoxicity in plants induced by contaminants and other stress agents has been hindered to date by the lack of reliable and robust biomarkers. The comet assay is a versatile and sensitive method for the evaluation of DNA damages and DNA repair capacity at single-cell level. Due to its simplicity and sensitivity, and the small number of cells required to obtain robust results, the use of plant comet assay has drastically increased in the last decade. For years its use was restricted to a few model species, e.g., Allium cepa, Nicotiana tabacum, Vicia faba, or Arabidopsis thaliana but this number largely increased in the last years. Plant comet assay has been used to study the genotoxic impact of radiation, chemicals including pesticides, phytocompounds, heavy metals, nanoparticles or contaminated complex matrices. Here we will review the most recent data on the use of this technique as a standard approach for studying the genotoxic effects of different stress conditions on plants. Also, we will discuss the integration of information provided by the comet assay with other DNA-damage indicators, and with cellular responses including oxidative stress, cell division or cell death. Finally, we will focus on putative relations between transcripts related with DNA damage pathways, DNA replication and repair, oxidative stress and cell cycle progression that have been identified in plant cells with comet assays demonstrating DNA damage. PMID:26175750

  12. Use of immunoblotting assay improves the sensitivity of paracoccidioidomycosis diagnosis

    Directory of Open Access Journals (Sweden)

    D. F. Silva

    2008-01-01

    Full Text Available The purpose of this work was to evaluate two serological assays: double immunodiffusion (DI and immunoblotting (IB in immunodiagnosis of paracoccidioidomycosis (PCM. We evaluated by IB assay 23 sera samples from patients with clinical confirmation of PCM, all of them with negative DI results against culture filtrate from Paracoccidioides brasiliensis isolate 113. For IB, as well as for comparative DI assay, we employed soluble components of the cell wall outer surface (SCCWOS from P. brasiliensis isolate 113 cultivated at 36°C in Fava-Neto's agar medium for 5 and 10 days. Among the 20 sera samples analyzed by DI, 13 (65% were negative and 7 (35% were positive against SCCWOS obtained on the 5th and 10th days. By IB assay, 95.4% and 100% of sera reacted against gp43 and gp70 present in SCCWOS from the 5th day and 95.6% recognized these fractions when evaluated against SCCWOS from the 10th day. Our results demonstrated that the use of an immunoenzymatic assay significantly improves the sensitivity of PCM immunodiagnosis and also suggests that at least two serological tests for antibody detection should be adopted in cases of questionable diagnosis.

  13. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  14. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    Science.gov (United States)

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CVADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Buried Waste Integrated Demonstration Plan

    International Nuclear Information System (INIS)

    Kostelnik, K.M.

    1991-12-01

    This document presents the plan of activities for the Buried Waste Integrated Demonstration (BWID) program which supports the environmental restoration (ER) objectives of the Department of Energy (DOE) Complex. Discussed in this plan are the objectives, organization, roles and responsibilities, and the process for implementing and managing BWID. BWID is hosted at the Idaho National Engineering Laboratory (INEL), but involves participants from throughout the DOE Complex, private industry, universities, and the international community. These participants will support, demonstrate, and evaluate a suite of advanced technologies representing a comprehensive remediation system for the effective and efficient remediation of buried waste. The processes for identifying technological needs, screening candidate technologies for applicability and maturity, selecting appropriate technologies for demonstration, field demonstrating, evaluation of results and transferring technologies to environmental restoration programs are also presented. This document further describes the elements of project planning and control that apply to BWID. It addresses the management processes, operating procedures, programmatic and technical objectives, and schedules. Key functions in support of each demonstration such as regulatory coordination, safety analyses, risk evaluations, facility requirements, and data management are presented

  16. Auditory demonstrations simulating Mayan architecture

    Science.gov (United States)

    Lubman, David

    2005-09-01

    Fascination with the ancient temples and ball court at Chichen Itza provide rich opportunities for science education. Children of all ages are delighted to learn that the sound of handclaps scattered from long temple staircases are transformed into bird chirps. Their engagement in such seemingly magical phenomena provides magic moments for teaching acoustical principals, including the picket-fence effect (PFE). PFE transforms impulsive sounds scattered from spatially periodic structures into tonal sounds. PFE is demonstrated with a computer possessing a sound card and a simple sound editing program. The inverse relationship between tonal frequency and the time interval between periodic impulses is easily demonstrated. The number of impulses needed to produce an audible tone is easily demonstrated and compared with the number of steps on the staircase. Transformation of audible tones into downward-gliding chirps is simulated by monotonically increasing the time between impulses. The Great Ball Court also provides opportunities for acoustical demonstration. Observers clapping their hands while standing between the long, tall, and parallel walls of the playing field marvel at the profound flutter echo heard for about 1.5 s. The flutter echo sonogram demonstrates the speed of sound and frequency-selective atmospheric attenuation.

  17. Demonstration of reliability centered maintenance

    International Nuclear Information System (INIS)

    Schwan, C.A.; Morgan, T.A.

    1991-04-01

    Reliability centered maintenance (RCM) is an approach to preventive maintenance planning and evaluation that has been used successfully by other industries, most notably the airlines and military. Now EPRI is demonstrating RCM in the commercial nuclear power industry. Just completed are large-scale, two-year demonstrations at Rochester Gas ampersand Electric (Ginna Nuclear Power Station) and Southern California Edison (San Onofre Nuclear Generating Station). Both demonstrations were begun in the spring of 1988. At each plant, RCM was performed on 12 to 21 major systems. Both demonstrations determined that RCM is an appropriate means to optimize a PM program and improve nuclear plant preventive maintenance on a large scale. Such favorable results had been suggested by three earlier EPRI pilot studies at Florida Power ampersand Light, Duke Power, and Southern California Edison. EPRI selected the Ginna and San Onofre sites because, together, they represent a broad range of utility and plant size, plant organization, plant age, and histories of availability and reliability. Significant steps in each demonstration included: selecting and prioritizing plant systems for RCM evaluation; performing the RCM evaluation steps on selected systems; evaluating the RCM recommendations by a multi-disciplinary task force; implementing the RCM recommendations; establishing a system to track and verify the RCM benefits; and establishing procedures to update the RCM bases and recommendations with time (a living program). 7 refs., 1 tab

  18. Demonstration of blind quantum computing.

    Science.gov (United States)

    Barz, Stefanie; Kashefi, Elham; Broadbent, Anne; Fitzsimons, Joseph F; Zeilinger, Anton; Walther, Philip

    2012-01-20

    Quantum computers, besides offering substantial computational speedups, are also expected to preserve the privacy of a computation. We present an experimental demonstration of blind quantum computing in which the input, computation, and output all remain unknown to the computer. We exploit the conceptual framework of measurement-based quantum computation that enables a client to delegate a computation to a quantum server. Various blind delegated computations, including one- and two-qubit gates and the Deutsch and Grover quantum algorithms, are demonstrated. The client only needs to be able to prepare and transmit individual photonic qubits. Our demonstration is crucial for unconditionally secure quantum cloud computing and might become a key ingredient for real-life applications, especially when considering the challenges of making powerful quantum computers widely available.

  19. Savannah River Plant incinerator demonstration

    International Nuclear Information System (INIS)

    Lewandowski, K.E.

    1983-01-01

    A full-scale incineration process was demonstrated at the Savannah River Laboratory (SRL) using nonradioactive waste. From October 1981 through September 1982, 15,700 kilograms of solid waste and 5.7 m 3 of solvent were incinerated. Emissions of off-gas components (NO/sub x/, SO 2 , CO, and particulates) were well below South Carolina state standards. Volume reductions of 20:1 for solid waste and 7:1 for Purex solvent/lime slurry were achieved. The process has been relocated and upgraded by the Savannah River Plant to accept low-level beta-gamma combustibles. During a two-year demonstration, the facility will incinerate slightly radioactive ( 3 ) solvent and suspect level (< 1 mR/h at 0.0254 meter) solid wastes. This demonstration will begin in early 1984

  20. Minimal_Set_of_In_Vitro_ER_Agonist_Assays_Selection_RegToxPharm_Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — A dataset for the manuscript which demonstrates that it is possible to achieve levels of performance equivalent to the full 16 assay ER agonist model against both in...

  1. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  2. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  3. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  4. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  5. Development of a plutonium solution-assay instrument with isotopic capability

    International Nuclear Information System (INIS)

    Hsue, S.T.; Marks, T.

    1992-01-01

    A new generation of solution-assay instrument has been developed to satisfy all the assay requirements of an aqueous plutonium-recovery operation. The assay is based on a transmission-corrected passive assay technique. We have demonstrated that the system can cover a concentration range of 0.5--300 g/ell with simultaneous isotopic determination. The system can be used to assay input and eluate streams of the recovery operation. The system can be modified to measure low-concentration effluent solutions from the recovery operation covering 0.01--40 g/ell. The same system has also been modified to assay plutonium solutions enriched in 242 Pu. 6 refs

  6. Demonstrating Fermat's Principle in Optics

    Science.gov (United States)

    Paleiov, Orr; Pupko, Ofir; Lipson, S. G.

    2011-01-01

    We demonstrate Fermat's principle in optics by a simple experiment using reflection from an arbitrarily shaped one-dimensional reflector. We investigated a range of possible light paths from a lamp to a fixed slit by reflection in a curved reflector and showed by direct measurement that the paths along which light is concentrated have either…

  7. Some Field Demonstrations in India

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. Some Field Demonstrations in India. 2x150kVAR STATCOM at M/s Hindusthan Latex, Trivandrum. 250kVAR, 800V dc, 2-level STATCOM (Installed at Peekey Steels, Calicut). 250kVAR,800V dc, UPQC at CDAC, Trivandrum. REFERENCE: Website www. cdac.gov.in.

  8. Flexible-Rotor Balancing Demonstration

    Science.gov (United States)

    Giordano, J.; Zorzi, E.

    1986-01-01

    Report describes method for balancing high-speed rotors at relatively low speeds and discusses demonstration of method on laboratory test rig. Method ensures rotor brought up to speeds well over 20,000 r/min smoothly, without excessive vibration amplitude at critical speeds or at operating speed.

  9. A Demonstration and a Souvenir

    Science.gov (United States)

    Lentz, Randy

    1978-01-01

    Describes an activity using interchangeable, preset tool holders to provide a demonstration for parents or students attending a school's open house session that produces a small souvenir (an aluminum mini-chalice) for them. A procedure sheet for the school's individual lathe and specification diagrams for making the cup are provided. (TA)

  10. NDT performance demonstration in Spain

    International Nuclear Information System (INIS)

    Bollini, G.J.

    1994-01-01

    The experience obtained from the in-service inspection of reactor pressure vessels (RPV) of Spanish nuclear power plants and the participation in several international programs, such as PISC, has shown the need for a performance demonstration, not only for the ultrasonic inspection techniques of RPV, but also for other ISI non-destructive techniques as in the case of eddy current inspection of steam generator tubing. Section XI of the ASME Code, which is applied in Spain for ISI, has incorporated recently the Appendix VIII for performance demonstration of ultrasonic inspection techniques. As a direct consequence of this, a Spanish project for performance demonstration of ultrasonic inspection techniques has been launched recently, which includes the manufacturing of full-scale mock-ups of nozzle to vessel welds, reactor vessel welds, wrought austenitic piping welds and ferritic piping welds of PWR and BWR nuclear power plants from different suppliers. This considerable technical effort will let the different Spanish organizations which are part of the project to participate and colaborate with similar international projects and in particular with a European initiative for performance demonstration. (Author)

  11. SunJammer Technology Demonstration

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sunjammer Project is a NASA funded contract to L?Garde Inc. to fly a solar sail demonstration for a period of approximately one year. L?Garde is also partnered...

  12. The buried waste integrated demonstration

    International Nuclear Information System (INIS)

    Kostelnik, K.M.

    1991-01-01

    There are numerous locations throughout the Department of Energy (DOE) Complex where wastes have been buried in the ground or stored for future disposal. Much of this buried waste is contaminated with hazardous and radioactive materials. An extensive research program has been initiated at the Idaho National Engineering Laboratory (INEL) to develop and demonstrate advanced remediation techniques for DOE Complex buried waste. The purpose of the Buried Waste Integrated Demonstration (BWID), is to develop a scientifically sound and deployable remediation system consisting of advanced technologies which address the buried waste characteristics of the DOE Complex. This comprehensive remediation system win include technologies for the entire remediation cycle (cradle-to-grave). Technologies developed and demonstrated within the BWID will be transferred to the DOE Complex sites with buried waste, to private industry, and to universities. Multidirectional technology transfer is encouraged by the BWID. Identification and evaluation of plausible technological solutions are an ongoing activity of the BWID. A number of technologies are currently under development throughout the DOE Complex, private industry, and universities. Technology integration mechanisms have been established by BWID to facilitate collaborative research and demonstration of applicable remedial technologies for buried waste. Successful completion of the BWID will result in the development of a proven and deployable system at the INEL and other DOE Complex buried waste sites, thereby supporting the DOE Complex's environmental restoration objectives

  13. E/Z MAS demonstration

    International Nuclear Information System (INIS)

    Boor, M.G.; Hurford, J.M.; Landry, R.P.; Martinez, B.J.; Solem, A.M.; Whiteson, R.; Zardecki, A.

    1998-01-01

    Los Alamos National Laboratory has developed E/Z MAS, a new generation nuclear material accountability application based on the latest technology and designed for facilities required to track nuclear materials with a simple-to-use interface. E/Z MAS is based on years of experience spent developing nuclear material accounting systems. E/Z MAS uses a modern relational database with a web server and enables users on a classified local area network to interact with the database with web browsers. The E/Z MAS Demonstration poster session demonstrates the E/Z MAS functions required by an operational nuclear facility to track material as it enters and leaves a facility and to account for the material as it moves through a process. The generation of internal facility reports and external reports for the Russian Federal system will be demonstrated. Bar-code readers will be used to demonstrate the ability of EZ MAS to automate certain functions, such as physical inventories at facilities

  14. US GCFR demonstration plant design

    International Nuclear Information System (INIS)

    Hunt, P.S.; Snyder, H.J.

    1980-05-01

    A general description of the US GCFR demonstration plant conceptual design is given to provide a context for more detailed papers to follow. The parameters selected for use in the design are presented and the basis for parameter selection is discussed. Nuclear steam supply system (NSSS) and balance of plant (BOP) component arrangements and systems are briefly discussed

  15. Satellite Demonstration: The Videodisc Technology.

    Science.gov (United States)

    Propp, George; And Others

    1979-01-01

    Originally part of a symposium on educational media for the deaf, the paper describes a satellite demonstration of video disc materials. It is explained that a panel of deaf individuals in Washington, D.C. and another in Nebraska came into direct two-way communication for the first time, and video disc materials were broadcast via the satellite.…

  16. Automated amperometric plutonium assay system

    International Nuclear Information System (INIS)

    Burt, M.C.

    1985-01-01

    The amperometric titration for plutonium assay has been used in the nuclear industry for over twenty years and has been in routine use at the Hanford Engineering Development Laboratory since 1976 for the analysis of plutonium oxide and mixed oxide fuel material for the Fast Flux Test Facility. It has proven itself to be an accurate and reliable method. The method may be used as a direct end point titration or an excess of titrant may be added and a back titration performed to aid in determination of the end point. Due to the slowness of the PuVI-FeII reaction it is difficult to recognize when the end point is being approached and is very time consuming if the current is allowed to decay to the residual value after each titrant addition. For this reason the back titration in which the rapid FeII-CrVI reaction occurs is used by most laboratories. The back titration is performed by the addition of excess ferrous solution followed by two measured aliquots of standard dichromate with measurement of cell current after each addition

  17. TRU assay system and measurements

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1984-02-01

    The measurement of the transuranic content of nuclear products or process residues has become increasingly important for the recovery of fissionable material from spent fuel elements, the identification of commercial fuel elements which have not yet reached full burnup, the measurement and recovery of transuranics from discarded or stored waste materials, the determination of the transuranic content in high gamma activity waste material scheduled for disposal, compliance with 10CFR61 by land burial operators/shippers, and the satisfaction of accountability requirements. Active neutron interrogation techniques measure either the prompt neutrons or the beta delayed neutrons from fission products following induced fission. These techniques normally only measure fissile transuranics ( 235 U, 239 Pu, and 241 Pu) and are commonly applied only to contact handleable waste. Passive neutron interrogation techniques, on the other hand, are capable of measuring all transuranics except 235 U with adequate sensitivity and will work on both contact handleable and high gamma activity wastes. Since the passive techniques are senstitive to a wider spectrum of transuranic isotopes than the active techniques, substantially less complex and less expensive than the active systems, and they have proven techniques for measuring small quantities of TRU in high gamma activity packages, the passive neutron TRU assay technology was chosen for development into the instruments discussed in this paper

  18. Micronucleus assay for radiation workers

    International Nuclear Information System (INIS)

    Balasem, A.N.; Ali, A.S.K.

    1997-01-01

    Micronucleus assay was performed on 49 radiation workers and 22 healthy volunteers. Radiation workers were subdivided into two groups according to their employments durations in the radiation field. Group a consisted of 18 radiation workers who have been in this work between 5 and 22 years. Group b included 31 employees who have been classified as radiation workers for 1 to 4.5 years. Statistical analysis showed significant variations between the yields of micronuclei in groups A and B as well as between group A and a group of healthy controls. Meanwhile no significant difference was noticed between the yields of micronuclei in group B and the corresponding values in the healthy controls. The possible effect of age in the induction of micronuclei was discussed and a comparison with the yield of chromosomal aberrations was described. It seems that cytokinesis- blocking method may be used to detect the radiation-induced micronuclei in workers exposed occupationally to ionizing radiation in levels below the maximum permissible limit of 0.05 Sv per year

  19. PAME: plasmonic assay modeling environment

    Directory of Open Access Journals (Sweden)

    Adam Hughes

    2015-08-01

    Full Text Available Plasmonic assays are an important class of optical sensors that measure biomolecular interactions in real-time without the need for labeling agents, making them especially well-suited for clinical applications. Through the incorporation of nanoparticles and fiberoptics, these sensing systems have been successfully miniaturized and show great promise for in-situ probing and implantable devices, yet it remains challenging to derive meaningful, quantitative information from plasmonic responses. This is in part due to a lack of dedicated modeling tools, and therefore we introduce PAME, an open-source Python application for modeling plasmonic systems of bulk and nanoparticle-embedded metallic films. PAME combines aspects of thin-film solvers, nanomaterials and fiber-optics into an intuitive graphical interface. Some of PAME’s features include a simulation mode, a database of hundreds of materials, and an object-oriented framework for designing complex nanomaterials, such as a gold nanoparticles encased in a protein shell. An overview of PAME’s theory and design is presented, followed by example simulations of a fiberoptic refractometer, as well as protein binding to a multiplexed sensor composed of a mixed layer of gold and silver colloids. These results provide new insights into observed responses in reflectance biosensors.

  20. Isotope release cytotoxicity assay applicable to human tumors: the use of 111-indium

    Energy Technology Data Exchange (ETDEWEB)

    Frost, P; Wiltrout, R; Maciorowski, Z; Rose, N R

    1977-01-01

    We have demonstrated that human tumors can be labelled efficiently with the 111indium-oxine chelate. Subsequently, this isotope can be released by cytotoxic lymphoid cells. Both natural and induced cytotoxicity can be demonstrated utilizing this isotope release method. Because of the slow spontaneous release of 111indium and its efficient labelling of human tumor cells, this isotope release assay can be utilized in long-term cytotoxic assays in the study of human tumor immunology.

  1. DOE's annealing prototype demonstration projects

    International Nuclear Information System (INIS)

    Warren, J.; Nakos, J.; Rochau, G.

    1997-01-01

    One of the challenges U.S. utilities face in addressing technical issues associated with the aging of nuclear power plants is the long-term effect of plant operation on reactor pressure vessels (RPVs). As a nuclear plant operates, its RPV is exposed to neutrons. For certain plants, this neutron exposure can cause embrittlement of some of the RPV welds which can shorten the useful life of the RPV. This RPV embrittlement issue has the potential to affect the continued operation of a number of operating U.S. pressurized water reactor (PWR) plants. However, RPV material properties affected by long-term irradiation are recoverable through a thermal annealing treatment of the RPV. Although a dozen Russian-designed RPVs and several U.S. military vessels have been successfully annealed, U.S. utilities have stated that a successful annealing demonstration of a U.S. RPV is a prerequisite for annealing a licensed U.S. nuclear power plant. In May 1995, the Department of Energy's Sandia National Laboratories awarded two cost-shared contracts to evaluate the feasibility of annealing U.S. licensed plants by conducting an anneal of an installed RPV using two different heating technologies. The contracts were awarded to the American Society of Mechanical Engineers (ASME) Center for Research and Technology Development (CRTD) and MPR Associates (MPR). The ASME team completed its annealing prototype demonstration in July 1996, using an indirect gas furnace at the uncompleted Public Service of Indiana's Marble Hill nuclear power plant. The MPR team's annealing prototype demonstration was scheduled to be completed in early 1997, using a direct heat electrical furnace at the uncompleted Consumers Power Company's nuclear power plant at Midland, Michigan. This paper describes the Department's annealing prototype demonstration goals and objectives; the tasks, deliverables, and results to date for each annealing prototype demonstration; and the remaining annealing technology challenges

  2. An ultrafiltration assay for lysyl oxidase

    International Nuclear Information System (INIS)

    Shackleton, D.R.; Hulmes, D.J.

    1990-01-01

    A modification of the original microdistillation assay for lysyl oxidase is described in which Amicon C-10 microconcentrators are used to separate, by ultrafiltration, the 3H-labeled products released from a [4,5-3H]-lysine-labeled elastin substrate. Enzyme activity is determined by scintillation counting of the ultrafiltrate, after subtraction of radioactivity released in the presence of beta-aminopropionitrile, a specific inhibitor of the enzyme. Conditions are described which optimize both the sensitivity and the efficient use of substrate. The assay shows linear inhibition of activity in up to 1 M urea; hence, as the enzyme is normally diluted in the assay, samples in 6 M urea can be assayed directly, without prior dialysis, and corrected for partial inhibition. Comparable results are obtained when enzyme activity is assayed by ultrafiltration or microdistillation. The assay is simple and convenient and, by using disposable containers throughout, it eliminates the need for time-consuming decontamination of radioactive glassware

  3. Assay development status report for total cyanide

    International Nuclear Information System (INIS)

    Simpson, B.C.; Jones, T.E.; Pool, K.H.

    1993-02-01

    A validated cyanide assay that is applicable to a variety of tank waste matrices is necessary to resolve certain waste tank safety issues and for purposes of overall waste characterization. The target for this effort is an assay with an applicable range of greater than 1,000 ppM (0.10 wt%) total cyanide and a confidence level greater than 80%. Figure 1 illustrates the operating regime of the proposed cyanide assay method. The Assay Development Status Report for Total Cyanide will summarize the past experience with cyanide analyses on-tank waste matrices and will rate the status of the analytical methods used to assay total cyanide (CN - ion) in the tank waste matrices as acceptable or unacceptable. This paper will also briefly describe the current efforts for improving analytical resolution of the assays and the attempts at speciation

  4. International network for comparison of HIV neutralization assays: the NeutNet report.

    Science.gov (United States)

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays. Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression. PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent. The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of neutralizing

  5. International network for comparison of HIV neutralization assays: the NeutNet report.

    Directory of Open Access Journals (Sweden)

    Eva Maria Fenyö

    Full Text Available Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1 vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet involving 18 independent participants was organized to compare different assays.Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4 at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (virus infectivity assays, VI assays, or their Env-pseudotyped (gp160 derivatives produced in 293T cells (PSV assays from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression.PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent.The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of

  6. Individual response to ionising radiation: What predictive assay(s) to choose?

    International Nuclear Information System (INIS)

    Granzotto, A.; Viau, M.; Devic, C.; Maalouf, M.; Thomas, Ch.; Vogin, G.; Foray, N.; Granzotto, A.; Vogin, G.; Balosso, J.; Joubert, A.; Maalouf, M.; Vogin, G.; Colin, C.; Malek, K.; Balosso, J.; Colin, C.

    2011-01-01

    Individual response to ionizing radiation is an important information required to apply an efficient radiotherapy treatment against tumour and to avoid any adverse effects in normal tissues. In 1981, Fertil and Malaise have demonstrated that the post-irradiation local tumor control determined in vivo is correlated with clonogenic cell survival assessed in vitro. Furthermore, these authors have reminded the relevance of the concept of intrinsic radiosensitivity that is specific to each individual organ (Fertil and Malaise, 1981) [1]. To date, since clonogenicity assays are too time-consuming and do not provide any other molecular information, a plethora of research groups have attempted to determine the molecular bases of intrinsic radiosensitivity in order to propose reliable and faster predictive assays. To this aim, several approaches have been developed. Notably, the recent revolution in genomic and proteomics technologies is providing a considerable number of data but their link with radiosensitivity still remains to be elucidated. On another hand, the systematic screening of some candidate genes potentially involved in the radiation response is highlighting the complexity of the molecular and cellular mechanisms of DNA damage sensing and signalling and shows that an abnormal radiation response is not necessarily due to the impairment of one single protein. Finally, more modest approaches consisting in focusing some specific functions of DNA repair seem to provide more reliable clues to predict over-acute reactions caused by radiotherapy. In this review, we endeavored to analyse the contributions of these major approaches to predict human radiosensitivity. (authors)

  7. Linearization of the Bradford Protein Assay

    OpenAIRE

    Ernst, Orna; Zor, Tsaffrir

    2010-01-01

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, t...

  8. New automated pellet/powder assay system

    International Nuclear Information System (INIS)

    Olsen, R.N.

    1975-01-01

    This paper discusses an automated, high precision, pellet/ powder assay system. The system is an active assay system using a small isotopic neutron source and a coincidence detection system. The handling of the pellet powder samples has been automated and a programmable calculator has been integrated into the system to provide control and data analysis. The versatile system can assay uranium or plutonium in either active or passive modes

  9. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  10. Irvine Smart Grid Demonstration, a Regional Smart Grid Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Yinger, Robert [Southern California Edison Company, Rosemead, CA (United States); Irwin, Mark [Southern California Edison Company, Rosemead, CA (United States)

    2015-12-29

    ISGD was a comprehensive demonstration that spanned the electricity delivery system and extended into customer homes. The project used phasor measurement technology to enable substation-level situational awareness, and demonstrated SCE’s next-generation substation automation system. It extended beyond the substation to evaluate the latest generation of distribution automation technologies, including looped 12-kV distribution circuit topology using URCIs. The project team used DVVC capabilities to demonstrate CVR. In customer homes, the project evaluated HAN devices such as smart appliances, programmable communicating thermostats, and home energy management components. The homes were also equipped with energy storage, solar PV systems, and a number of energy efficiency measures (EEMs). The team used one block of homes to evaluate strategies and technologies for achieving ZNE. A home achieves ZNE when it produces at least as much renewable energy as the amount of energy it consumes annually. The project also assessed the impact of device-specific demand response (DR), as well as load management capabilities involving energy storage devices and plug-in electric vehicle charging equipment. In addition, the ISGD project sought to better understand the impact of ZNE homes on the electric grid. ISGD’s SENet enabled end-to-end interoperability between multiple vendors’ systems and devices, while also providing a level of cybersecurity that is essential to smart grid development and adoption across the nation. The ISGD project includes a series of sub-projects grouped into four logical technology domains: Smart Energy Customer Solutions, Next-Generation Distribution System, Interoperability and Cybersecurity, and Workforce of the Future. Section 2.3 provides a more detailed overview of these domains.

  11. Pu-238 assay performance with the Canberra IQ3 system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, L.; Gillespie, B.; Seaman, G.

    1997-11-01

    Canberra Industries has recently completed a demonstration project at the Westinghouse Savannah River Site (WSRC) to characterize 55-gallon drums containing Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 waste to detection limits of less than 50 nCi/g using gamma assay techniques. This would permit reclassification of these drums from transuranic (TRU) waste to low-level waste (LLW). The instrument used for this assay was a Canberra IQ3 high sensitivity gamma assay system, mounted in a trailer. The results of the measurements demonstrate achievement of detection levels as low as 1 nCi/g for low density waste drums, and good correlation with known concentrations in several test drums. In addition, the data demonstrates significant advantages for using large area low-energy germanium detectors for achieving the lowest possible MDAs for gamma rays in the 80-250 keV range. 1 fig., 2 tabs.

  12. 233U Assay A Neutron NDA System

    Energy Technology Data Exchange (ETDEWEB)

    Hensley, D.C.; Lucero, A.J.; Pierce, L.

    1998-11-17

    The assay of highly enriched {sup 233}U material presents some unique challenges. Techniques which apply to the assay of materials of Pu or enriched {sup 235}U do not convert easily over to the assay of {sup 233}U. A specialized neutron assay device is being fabricated to exploit the singles neutron signal, the weak correlated neutron signal, and an active correlated signal. These pieces of information when combined with {gamma} ray isotopics information should give a good overall determination of {sup 233}U material now stored in bldg. 3019 at the Oak Ridge National Laboratory.

  13. 233U Assay A Neutron NDA System

    International Nuclear Information System (INIS)

    Hensley, D.C.; Lucero, A.J.; Pierce, L.

    1998-01-01

    The assay of highly enriched 233 U material presents some unique challenges. Techniques which apply to the assay of materials of Pu or enriched 235 U do not convert easily over to the assay of 233 U. A specialized neutron assay device is being fabricated to exploit the singles neutron signal, the weak correlated neutron signal, and an active correlated signal. These pieces of information when combined with γ ray isotopics information should give a good overall determination of 233 U material now stored in bldg. 3019 at the Oak Ridge National Laboratory

  14. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  15. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  16. Incineration demonstration at Savannah River

    International Nuclear Information System (INIS)

    Lewandowski, K.E.; Becker, G.W.; Mersman, K.E.; Roberson, W.A.

    1983-01-01

    A full-scale incineration process for Savannah River Plant (SRP) low level beta-gamma combustible waste was demonstrated at the Savannah River Laboratory (SRL) using nonradioactive wastes. From October 1981 through September 1982, 15,700 kilograms of solid waste and 5.7 m 3 of solvent were incinerated. Emissions of off-gas components (NO/sub x/, SO 2 , CO, and particulates) were well below South Carolina state standards. Volume reductions of 20:1 for solid waste and 7:1 for Purex solvent/lime slurry were achieved. Presently, the process is being upgraded by SRP to accept radioactive wastes. During a two-year SRP demonstration, the facility will be used to incinerate slightly radioactive ( 3 ) solvent and suspect level (<1 mR/hr at 0.0254 meter) solid wastes

  17. Plasma hearth process demonstration project

    International Nuclear Information System (INIS)

    Geimer, R.M.; Gillins, R.L.

    1995-01-01

    The Plasma Hearth Process (PHP) demonstration project is one of the key technology projects in the US Department of Energy (DOE) Office of Technology Development Mixed Waste Focus Area. The PHP is a high temperature thermal treatment process using a plasma arc torch in a stationary, refractory lined chamber that destroys organics and stabilizes the residuals in a nonleaching, vitrified waste form, greatly improving the disposability of the waste. This paper describes the PHP system and summarizes test results to date, including volume reduction, destruction and removal efficiencies for organic wastes, and emission characteristics. Tests performed so far demonstrate that the PHP adresses DOE mixed waste final waste form requirements and US Environmental Protection Agency Toxicity Characteristic Leaching Procedure requirements

  18. Actinide Separation Demonstration Facility, Tarapur

    International Nuclear Information System (INIS)

    Vishwaraj, I.

    2017-01-01

    Partitioning of minor actinide from high level waste could have a substantial impact in lowering the radio toxicity associated with high level waste as well as it will reduce the burden on geological repository. In Indian context, the partitioned minor actinide could be routed into the fast breeder reactor systems scheduled for commissioning in the near period. The technological breakthrough in solvent development has catalyzed the partitioning programme in India, leading to the setting up and hot commissioning of the Actinide Separation Demonstration Facility (ASDF) at BARC, Tarapur. The engineering scale Actinide Separation Demonstration Facility (ASDF) has been retrofitted in an available radiological hot cell situated adjacent to the Advanced Vitrification Facility (AVS). This location advantage ensures an uninterrupted supply of high-level waste and facilitates the vitrification of the high-level waste after separation of minor actinides

  19. Earth Science Capability Demonstration Project

    Science.gov (United States)

    Cobleigh, Brent

    2006-01-01

    A viewgraph presentation reviewing the Earth Science Capability Demonstration Project is shown. The contents include: 1) ESCD Project; 2) Available Flight Assets; 3) Ikhana Procurement; 4) GCS Layout; 5) Baseline Predator B Architecture; 6) Ikhana Architecture; 7) UAV Capability Assessment; 8) The Big Picture; 9) NASA/NOAA UAV Demo (5/05 to 9/05); 10) NASA/USFS Western States Fire Mission (8/06); and 11) Suborbital Telepresence.

  20. Mixed Waste Landfill Integrated Demonstration

    International Nuclear Information System (INIS)

    1994-02-01

    The mission of the Mixed Waste Landfill Integrated Demonstration (MWLID) is to demonstrate, in contaminated sites, new technologies for clean-up of chemical and mixed waste landfills that are representative of many sites throughout the DOE Complex and the nation. When implemented, these new technologies promise to characterize and remediate the contaminated landfill sites across the country that resulted from past waste disposal practices. Characterization and remediation technologies are aimed at making clean-up less expensive, safer, and more effective than current techniques. This will be done by emphasizing in-situ technologies. Most important, MWLID's success will be shared with other Federal, state, and local governments, and private companies that face the important task of waste site remediation. MWLID will demonstrate technologies at two existing landfills. Sandia National Laboratories' Chemical Waste Landfill received hazardous (chemical) waste from the Laboratory from 1962 to 1985, and the Mixed-Waste Landfill received hazardous and radioactive wastes (mixed wastes) over a twenty-nine year period (1959-1988) from various Sandia nuclear research programs. Both landfills are now closed. Originally, however, the sites were selected because of Albuquerque's and climate and the thick layer of alluvial deposits that overlay groundwater approximately 480 feet below the landfills. This thick layer of ''dry'' soils, gravel, and clays promised to be a natural barrier between the landfills and groundwater

  1. Salt decontamination demonstration test results

    International Nuclear Information System (INIS)

    Snell, E.B.; Heng, C.J.

    1983-06-01

    The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10 3 d/m/ml versus a goal of less than 10 4 d/m/ml; and (4) the concentrated precipitate was washed to a final sodium ion concentration of 0.15 M, well below the 0.225 M upper limit for DWPF feed. These accomplishments were achieved on schedule and without incident. Total radiation exposure to personnel was less than 350 mrem and resulted primarily from sampling precipitate slurry inside tank 48. 3 references, 6 figures, 2 tables

  2. Aerospace Communications Security Technologies Demonstrated

    Science.gov (United States)

    Griner, James H.; Martzaklis, Konstantinos S.

    2003-01-01

    In light of the events of September 11, 2001, NASA senior management requested an investigation of technologies and concepts to enhance aviation security. The investigation was to focus on near-term technologies that could be demonstrated within 90 days and implemented in less than 2 years. In response to this request, an internal NASA Glenn Research Center Communications, Navigation, and Surveillance Aviation Security Tiger Team was assembled. The 2-year plan developed by the team included an investigation of multiple aviation security concepts, multiple aircraft platforms, and extensively leveraged datalink communications technologies. It incorporated industry partners from NASA's Graphical Weather-in-the-Cockpit research, which is within NASA's Aviation Safety Program. Two concepts from the plan were selected for demonstration: remote "black box," and cockpit/cabin surveillance. The remote "black box" concept involves real-time downlinking of aircraft parameters for remote monitoring and archiving of aircraft data, which would assure access to the data following the loss or inaccessibility of an aircraft. The cockpit/cabin surveillance concept involves remote audio and/or visual surveillance of cockpit and cabin activity, which would allow immediate response to any security breach and would serve as a possible deterrent to such breaches. The datalink selected for the demonstrations was VDL Mode 2 (VHF digital link), the first digital datalink for air-ground communications designed for aircraft use. VDL Mode 2 is beginning to be implemented through the deployment of ground stations and aircraft avionics installations, with the goal of being operational in 2 years. The first demonstration was performed December 3, 2001, onboard the LearJet 25 at Glenn. NASA worked with Honeywell, Inc., for the broadcast VDL Mode 2 datalink capability and with actual Boeing 757 aircraft data. This demonstration used a cockpitmounted camera for video surveillance and a coupling to

  3. Mouse lung adhesion assay for Bordetella pertussis

    Energy Technology Data Exchange (ETDEWEB)

    Burns, K A; Freer, J H [Department of Microbiology, Alexander Stone Building, Bearsden, Glasgow, Scotland

    1982-03-01

    The ability of Bordetella pertussis to adhere to cell surfaces has been demonstrated by adhesion to tissue culture cells and adhesion to chicken, hamster or rabbit trachea in organ culture. In this report a mouse lung assay for adhesion is described and the results obtained using two virulent strains of B. pertussis and their avirulent counterparts. These were a C modulation of one of the original virulent strains and a phase IV variant of the other virulent strain. Organisms were radiolabelled by adding 1 ..mu..Ci (37 K Bq) of (/sup 14/C)glutamic acid per 10 ml of culture medium before inoculation and incubation for 5 days. The lungs were washed by perfusion in situ with at least two volumes (1 ml) of sterile 1% (w/v) casamino acids. The percentage of the inoculated organisms retained in the lungs was determined, after removal of the lungs, by one of the following two methods: viable count or radioactive count. Results for both methods were expressed as the percentage of the inoculum retained in the lungs plus or minus one standard deviation.

  4. Mouse lung adhesion assay for Bordetella pertussis

    International Nuclear Information System (INIS)

    Burns, K.A.; Freer, J.H.

    1982-01-01

    The ability of Bordetella pertussis to adhere to cell surfaces has been demonstrated by adhesion to tissue culture cells and adhesion to chicken, hamster or rabbit trachea in organ culture. In this report a mouse lung assay for adhesion is described and the results obtained using two virulent strains of B. pertussis and their avirulent counterparts. These were a C modulation of one of the original virulent strains and a phase IV variant of the other virulent strain. Organisms were radiolabelled by adding 1 μCi (37 K Bq) of [ 14 C]glutamic acid per 10 ml of culture medium before inoculation and incubation for 5 days. The lungs were washed by perfusion in situ with at least two volumes (1 ml) of sterile 1% (w/v) casamino acids. The percentage of the inoculated organisms retained in the lungs was determined, after removal of the lungs, by one of the following two methods: viable count or radioactive count. Results for both methods were expressed as the percentage of the inoculum retained in the lungs plus or minus one standard deviation. (Auth.)

  5. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  6. A radiochemical assay for biotin in biological materials

    International Nuclear Information System (INIS)

    Hood, R.L.

    1975-01-01

    A radiochemical assay for biotin is described. The assay was sensitive to one nanogram and simple enough for routine biotin analyses. The assay yielded results which were comparable to those obtained from a microbiological assay using Lactobacillus plantarum. (author)

  7. A Functional Henipavirus Envelope Glycoprotein Pseudotyped Lentivirus Assay System

    Directory of Open Access Journals (Sweden)

    Broder Christopher C

    2010-11-01

    Full Text Available Abstract Background Hendra virus (HeV and Nipah virus (NiV are newly emerged zoonotic paramyxoviruses discovered during outbreaks in Queensland, Australia in 1994 and peninsular Malaysia in 1998/9 respectively and classified within the new Henipavirus genus. Both viruses can infect a broad range of mammalian species causing severe and often-lethal disease in humans and animals, and repeated outbreaks continue to occur. Extensive laboratory studies on the host cell infection stage of HeV and NiV and the roles of their envelope glycoproteins have been hampered by their highly pathogenic nature and restriction to biosafety level-4 (BSL-4 containment. To circumvent this problem, we have developed a henipavirus envelope glycoprotein pseudotyped lentivirus assay system using either a luciferase gene or green fluorescent protein (GFP gene encoding human immunodeficiency virus type-1 (HIV-1 genome in conjunction with the HeV and NiV fusion (F and attachment (G glycoproteins. Results Functional retrovirus particles pseudotyped with henipavirus F and G glycoproteins displayed proper target cell tropism and entry and infection was dependent on the presence of the HeV and NiV receptors ephrinB2 or B3 on target cells. The functional specificity of the assay was confirmed by the lack of reporter-gene signals when particles bearing either only the F or only G glycoprotein were prepared and assayed. Virus entry could be specifically blocked when infection was carried out in the presence of a fusion inhibiting C-terminal heptad (HR-2 peptide, a well-characterized, cross-reactive, neutralizing human mAb specific for the henipavirus G glycoprotein, and soluble ephrinB2 and B3 receptors. In addition, the utility of the assay was also demonstrated by an examination of the influence of the cytoplasmic tail of F in its fusion activity and incorporation into pseudotyped virus particles by generating and testing a panel of truncation mutants of NiV and HeV F

  8. Exploration Medical System Demonstration Project

    Science.gov (United States)

    Chin, D. A.; McGrath, T. L.; Reyna, B.; Watkins, S. D.

    2011-01-01

    A near-Earth Asteroid (NEA) mission will present significant new challenges including hazards to crew health created by exploring a beyond low earth orbit destination, traversing the terrain of asteroid surfaces, and the effects of variable gravity environments. Limited communications with ground-based personnel for diagnosis and consultation of medical events require increased crew autonomy when diagnosing conditions, creating treatment plans, and executing procedures. Scope: The Exploration Medical System Demonstration (EMSD) project will be a test bed on the International Space Station (ISS) to show an end-to-end medical system assisting the Crew Medical Officers (CMO) in optimizing medical care delivery and medical data management during a mission. NEA medical care challenges include resource and resupply constraints limiting the extent to which medical conditions can be treated, inability to evacuate to Earth during many mission phases, and rendering of medical care by a non-clinician. The system demonstrates the integration of medical technologies and medical informatics tools for managing evidence and decision making. Project Objectives: The objectives of the EMSD project are to: a) Reduce and possibly eliminate the time required for a crewmember and ground personnel to manage medical data from one application to another. b) Demonstrate crewmember's ability to access medical data/information via a software solution to assist/aid in the treatment of a medical condition. c) Develop a common data management architecture that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all crew health and life sciences activities. d) Develop a common data management architecture that allows for scalability, extensibility, and interoperability of data sources and data users. e) Lower total cost of ownership for development and sustainment of peripheral hardware and software that use EMSD for data management f) Provide

  9. AAEC builds synroc demonstration plant

    International Nuclear Information System (INIS)

    O'Hagan, R.

    1986-01-01

    A demonstration plant to test the feasibility of an Australian-developed method of immobilising radioactive waste is being built at the Australian Atomic Energy Commission's Lucas Heights Research Laboratories. The plant will operate as if radioactive waste was actually being processed, but non-radioactive elements of a similar composition will be used. The process involves the simulated waste being mixed into a slurry with the main SYNROC ingredients and then converted to a powder. The powder is moved about the plant in bellows-type containers by robots

  10. Charge sniffer for electrostatics demonstrations

    Science.gov (United States)

    Dinca, Mihai P.

    2011-02-01

    An electronic electroscope with a special design for demonstrations and experiments on static electricity is described. It operates as an electric charge sniffer by detecting slightly charged objects when they are brought to the front of its sensing electrode. The sniffer has the advantage of combining high directional sensitivity with a logarithmic bar display. It allows for the identification of electric charge polarity during charge separation by friction, peeling, electrostatic induction, batteries, or secondary coils of power transformers. Other experiments in electrostatics, such as observing the electric field of an oscillating dipole and the distance dependence of the electric field generated by simple charge configurations, are also described.

  11. Dynamic Underground Stripping Demonstration Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; udel, K.

    1992-03-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving to the contaminated site in FY 92

  12. Vitamin D assays: past and present debates, difficulties, and developments.

    Science.gov (United States)

    Fraser, William D; Milan, Anna M

    2013-02-01

    Clinical interest in Vitamin D and its purported roles not only in calcium and bone metabolism but in several other medical conditions (diabetes, cardiovascular disease, multiple sclerosis, cancer, psychiatric disorders, neuro-muscular disease) has led to a surge in laboratory requests for 25 hydroxy vitamin D and 1,25 dihydroxy vitamin D measurement. Circulating 25 hydroxy vitamin D concentration is routinely used as the best indicator of vitamin D status, but measurement of other metabolites, especially the physiologically active 1,25 dihyroxy vitamin D, are of clinical value. Over the last 40 years the development of assays for vitamin D and its metabolites from early competitive binding assays through to immunoassay and liquid chromatography aligned to mass spectrometry have demonstrated various analytical challenges, the advantages and disadvantages of each method are constantly changing with new technological developments. Immunoassay remains the predominant mode of measurement for 25-hydroxy vitamin D although problems with equimolar recovery of the D2 and D3 metabolites remain an issue. Standardisation of all assays has been improved but not resolved with the currently available reference materials as evidenced by the international vitamin D external quality assurance scheme, DEQAS. The choice of method for each laboratory remains a balance mainly between turn around time, convenience, cost and the specificity and accuracy of the information obtained. With increasing discussion and clinical interest surrounding other vitamin D metabolites the vitamin D assay debate is set to continue.

  13. Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays.

    Science.gov (United States)

    Adhikari, Meena; Strych, Ulrich; Kim, Jinsu; Goux, Heather; Dhamane, Sagar; Poongavanam, Mohan-Vivekanandan; Hagström, Anna E V; Kourentzi, Katerina; Conrad, Jacinta C; Willson, Richard C

    2015-12-01

    We introduce the modification of bacteriophage particles with aptamers for use as bioanalytical reporters, and demonstrate the use of these particles in ultrasensitive lateral flow assays. M13 phage displaying an in vivo biotinylatable peptide (AviTag) genetically fused to the phage tail protein pIII were used as reporter particle scaffolds, with biotinylated aptamers attached via avidin-biotin linkages, and horseradish peroxidase (HRP) reporter enzymes covalently attached to the pVIII coat protein. These modified viral nanoparticles were used in immunochromatographic sandwich assays for the direct detection of IgE and of the penicillin-binding protein from Staphylococcus aureus (PBP2a). We also developed an additional lateral flow assay for IgE, in which the analyte is sandwiched between immobilized anti-IgE antibodies and aptamer-bearing reporter phage modified with HRP. The limit of detection of this LFA was 0.13 ng/mL IgE, ∼100 times lower than those of previously reported IgE assays.

  14. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  15. Assessing sediment contamination using six toxicity assays

    Directory of Open Access Journals (Sweden)

    Allen G. BURTON Jr.

    2001-08-01

    Full Text Available An evaluation of sediment toxicity at Lake Orta, Italy was conducted to compare a toxicity test battery of 6 assays and to evaluate the extent of sediment contamination at various sediment depths. Lake Orta received excessive loadings of copper and ammonia during the 1900’s until a large remediation effort was conducted in 1989-90 using lime addition. Since that time, the lake has shown signs of a steady recovery of biological communities. The study results showed acute toxicity still exists in sediments at a depth of 5 cm and greater. Assays that detected the highest levels of toxicity were two whole sediment exposures (7 d using Hyalella azteca and Ceriodaphnia dubia. The MicrotoxR assay using pore water was the third most sensitive assay. The Thamnotox, Rototox, Microtox solid phase, and Seed Germination-Root Elongation (pore and solid phase assays showed occasional to no toxicity. Based on similarity of responses and assay sensitivity, the two most useful assays were the C. dubia (or H. azteca and Microtox pore water. These assays were effective at describing sediment toxicity in a weight-of-evidence approach.

  16. A Continuous, Fluorogenic Sirtuin 2 Deacylase Assay

    DEFF Research Database (Denmark)

    Galleano, Iacopo; Schiedel, Matthias; Jung, Manfred

    2016-01-01

    and kinetic insight regarding sirtuin inhibitors, it is important to have access to efficient assays. In this work, we report readily synthesized fluorogenic substrates enabling enzyme-economical evaluation of SIRT2 inhibitors in a continuous assay format as well as evaluation of the properties of SIRT2...

  17. 21 CFR 864.7525 - Heparin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heparin assay. 864.7525 Section 864.7525 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7525 Heparin assay. (a) Identification. A...

  18. Flambeau River Biofuels Demonstration Plant

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, Robert J. [Flambeau River Biofuels, Inc., Park Falls, WI (United States)

    2012-07-30

    Flambeau River BioFuels, Inc. (FRB) proposed to construct a demonstration biomass-to-liquids (BTL) biorefinery in Park Falls, Wisconsin. The biorefinery was to be co-located at the existing pulp and paper mill, Flambeau River Papers, and when in full operation would both generate renewable energy – making Flambeau River Papers the first pulp and paper mill in North America to be nearly fossil fuel free – and produce liquid fuels from abundant and renewable lignocellulosic biomass. The biorefinery would serve to validate the thermochemical pathway and economic models for BTL production using forest residuals and wood waste, providing a basis for proliferating BTL conversion technologies throughout the United States. It was a project goal to create a compelling new business model for the pulp and paper industry, and support the nation’s goal for increasing renewable fuels production and reducing its dependence on foreign oil. FRB planned to replicate this facility at other paper mills after this first demonstration scale plant was operational and had proven technical and economic feasibility.

  19. Parker Hybrid Hydraulic Drivetrain Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Collett, Raymond [Parker-Hannifin Corporation, Cleveland, OH (United States); Howland, James [Parker-Hannifin Corporation, Cleveland, OH (United States); Venkiteswaran, Prasad [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2014-03-31

    This report examines the benefits of Parker Hannifin hydraulic hybrid brake energy recovery systems used in commercial applications for vocational purposes. A detailed background on the problem statement being addressed as well as the solution set specific for parcel delivery will be provided. Objectives of the demonstration performed in high start & stop applications included opportunities in fuel usage reduction, emissions reduction, vehicle productivity, and vehicle maintenance. Completed findings during the demonstration period and parallel investigations with NREL, CALSTART, along with a literature review will be provided herein on this research area. Lastly, results identified in the study by third parties validated the savings potential in fuel reduction of on average of 19% to 52% over the baseline in terms of mpg (Lammert, 2014, p11), Parker data for parcel delivery vehicles in the field parallels this at a range of 35% - 50%, emissions reduction of 17.4% lower CO2 per mile and 30.4% lower NOx per mile (Gallo, 2014, p15), with maintenance improvement in the areas of brake and starter replacement, while leaving room for further study in the area of productivity in terms of specific metrics that can be applied and studied.

  20. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  1. Rapid Diagnostic Assay for Intact Influenza Virus Using a High Affinity Hemagglutinin Binding Protein.

    Science.gov (United States)

    Anderson, Caitlin E; Holstein, Carly A; Strauch, Eva-Maria; Bennett, Steven; Chevalier, Aaron; Nelson, Jorgen; Fu, Elain; Baker, David; Yager, Paul

    2017-06-20

    Influenza is a ubiquitous and recurring infection that results in approximately 500 000 deaths globally each year. Commercially available rapid diagnostic tests are based upon detection of the influenza nucleoprotein, which are limited in that they are unable to differentiate by species and require an additional viral lysis step. Sample preprocessing can be minimized or eliminated by targeting the intact influenza virus, thereby reducing assay complexity and leveraging the large number of hemagglutinin proteins on the surface of each virus. Here, we report the development of a paper-based influenza assay that targets the hemagglutinin protein; the assay employs a combination of antibodies and novel computationally designed, recombinant affinity proteins as the capture and detection agents. This system leverages the customizability of recombinant protein design to target the conserved receptor-binding pocket of the hemagglutinin protein and to match the trimeric nature of hemagglutinin for improved avidity. Using this assay, we demonstrate the first instance of intact influenza virus detection using a combination of antibody and affinity proteins within a porous network. The recombinant head region binder based assays yield superior analytical sensitivity as compared to the antibody based assay, with lower limits of detection of 3.54 × 10 7 and 1.34 × 10 7 CEID 50 /mL for the mixed and all binder stacks, respectively. Not only does this work describe the development of a novel influenza assay, it also demonstrates the power of recombinant affinity proteins for use in rapid diagnostic assays.

  2. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  3. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  4. Energy 2007. Research, development, demonstration; Energi 07. Forskning, udvikling, demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Byriel, I.P.; Justesen, Helle; Beck, A.; Borup Jensen, J.; Rosenfeldt Jakobsen, Kl; Jacobsen, Steen Hartvig (eds.)

    2007-08-10

    Danish energy research is in an exciting and challenging situation. Rising oil prices, unstable energy supply, climate policy responsibilities and globalization have brought development of new environmentally friendly and more efficient energy technologies into focus. Promising international markets for newly developed energy technologies are emerging, and at the same time well established Danish positions of strength are challenged by new strong actors on the global market. The Danish government has set to work on its vision of an appreciable strengthening of public energy research funding through the recent law on the energy technological development and demonstration programme EUDP and the realization of globalization funds. The interaction between basic and applied research must be kept intact. In this report the various Danish energy research programmes administered by Energinet.dk, Danish Energy Authority, Danish Energy Association, Danish Council for Strategic Research's Programme Commission on Energy and Environment and Danish National Advanced Technology Foundation, coordinate their annual reports for the first time. The aim of Energy 2007 is to give the reader an idea of how the energy research programmes collaborate on solving the major energy technology challenges - also in an international context. (BA)

  5. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  6. DOE assay methods used for characterization of contact-handled transuranic waste

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, F.J. (Oak Ridge National Lab., TN (United States)); Caldwell, J.T. (Pajarito Scientific Corp., Los Alamos, NM (United States))

    1991-08-01

    US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and Materials. American National Standards Institute, or Nuclear Regulatory Commission guidelines or methods describing proper calibration procedures, equipment setup, etc., comparisons of PAN data with the more established assay methods (e.g., segmented gamma scanning) have demonstrated its reliability and accuracy. Assay methods employed by DOE have been shown to reliable and accurate in determining fissile, radionuclide, alpha-curie content, and decay heat values of CH-TRU wastes. These parameters are therefore used to characterize packaged waste for use in certification programs such as that used in shipment of CH-TRU waste to the WIPP. 36 refs., 10 figs., 7 tabs.

  7. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  8. DOE assay methods used for characterization of contact-handled transuranic waste

    International Nuclear Information System (INIS)

    Schultz, F.J.; Caldwell, J.T.

    1991-08-01

    US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and Materials. American National Standards Institute, or Nuclear Regulatory Commission guidelines or methods describing proper calibration procedures, equipment setup, etc., comparisons of PAN data with the more established assay methods (e.g., segmented gamma scanning) have demonstrated its reliability and accuracy. Assay methods employed by DOE have been shown to reliable and accurate in determining fissile, radionuclide, alpha-curie content, and decay heat values of CH-TRU wastes. These parameters are therefore used to characterize packaged waste for use in certification programs such as that used in shipment of CH-TRU waste to the WIPP. 36 refs., 10 figs., 7 tabs

  9. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  10. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 2 discusses the following topics: Fuel Rod Extraction System Test Results and Analysis Reports and Clamping Table Test Results and Analysis Reports

  11. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 1 discusses the following topics: the background of the project; test program description; summary of tests and test results; problem evaluation; functional requirements confirmation; recommendations; and completed test documentation for tests performed in Phase 3

  12. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 1 of Volume IV, discusses: Process overview functional descriptions; Control system descriptions; Support system descriptions; Maintenance system descriptions; and Process equipment descriptions

  13. Demonstration of creep during filtration

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Bugge, Thomas Vistisen; Kirchheiner, Anders Løvenbalk

    The classical filtration theory assumes a unique relationship between the local filter cake porosity and the local effective pressure. For a number of compressible materials, it has however been observed that during the consolidation stage this may not be the case. It has been found...... that the production of filtrate also depends on the characteristic time for the filter cake solids to deform. This is formulated in the Terzaghi-Voigt model in which a secondary consolidation is introduced. The secondary consolidation may be visualized by plots of the relative cake deformation (U) v.s. the square...... root of time. Even more clearly it is demonstrated by plotting the liquid pressure at the cake piston interface v.s. the relative deformation (to be shown). The phenomenon of a secondary consolidation processes is in short called creep. Provided that the secondary consolidation rate is of the same...

  14. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 9 discusses the following topics: Integrated System Normal Operations Test Results and Analysis Report; Integrated System Off-Normal Operations Test Results and Analysis Report; and Integrated System Maintenance Operations Test Results and Analysis Report

  15. Clean Coal Diesel Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Robert Wilson

    2006-10-31

    A Clean Coal Diesel project was undertaken to demonstrate a new Clean Coal Technology that offers technical, economic and environmental advantages over conventional power generating methods. This innovative technology (developed to the prototype stage in an earlier DOE project completed in 1992) enables utilization of pre-processed clean coal fuel in large-bore, medium-speed, diesel engines. The diesel engines are conventional modern engines in many respects, except they are specially fitted with hardened parts to be compatible with the traces of abrasive ash in the coal-slurry fuel. Industrial and Municipal power generating applications in the 10 to 100 megawatt size range are the target applications. There are hundreds of such reciprocating engine power-plants operating throughout the world today on natural gas and/or heavy fuel oil.

  16. Alderney 5 complex demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, D. [High Performance Energy Systems, Halifax, NS (Canada)

    2008-07-01

    The Halifax Regional Municipality (HRM) is the largest municipality in Atlantic Canada. This presentation described the flagship facility and the energy efficiency retrofit of five HRM-owned buildings called the Alderney 5 complex. The 5 objectives of the demonstration project involved a district-scale cooling project; replacement of chillers with harbour cooling; and replacement of a high exergy system with a low exergy system. Synergies and challenges of the project were also identified. The presentation also referred to borehole thermal energy storage; existing Halifax Harbour cooling; Halifax Harbour temperatures; cold energy geothermal borehole field; and the benefits of advanced concentric boreholes. A project update and progress to date were also provided. The Alderney 5 project represents the first concentric borehole technology for use to store and retrieve cold energy. tabs., figs.

  17. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 8 discusses Control System SOT Tests Results and Analysis Report. This is a continuation of Book 7

  18. Deep Space Habitat Concept Demonstrator

    Science.gov (United States)

    Bookout, Paul S.; Smitherman, David

    2015-01-01

    This project will develop, integrate, test, and evaluate Habitation Systems that will be utilized as technology testbeds and will advance NASA's understanding of alternative deep space mission architectures, requirements, and operations concepts. Rapid prototyping and existing hardware will be utilized to develop full-scale habitat demonstrators. FY 2014 focused on the development of a large volume Space Launch System (SLS) class habitat (Skylab Gen 2) based on the SLS hydrogen tank components. Similar to the original Skylab, a tank section of the SLS rocket can be outfitted with a deep space habitat configuration and launched as a payload on an SLS rocket. This concept can be used to support extended stay at the Lunar Distant Retrograde Orbit to support the Asteroid Retrieval Mission and provide a habitat suitable for human missions to Mars.

  19. Navy fuel cell demonstration project.

    Energy Technology Data Exchange (ETDEWEB)

    Black, Billy D.; Akhil, Abbas Ali

    2008-08-01

    This is the final report on a field evaluation by the Department of the Navy of twenty 5-kW PEM fuel cells carried out during 2004 and 2005 at five Navy sites located in New York, California, and Hawaii. The key objective of the effort was to obtain an engineering assessment of their military applications. Particular issues of interest were fuel cell cost, performance, reliability, and the readiness of commercial fuel cells for use as a standalone (grid-independent) power option. Two corollary objectives of the demonstration were to promote technological advances and to improve fuel performance and reliability. From a cost perspective, the capital cost of PEM fuel cells at this stage of their development is high compared to other power generation technologies. Sandia National Laboratories technical recommendation to the Navy is to remain involved in evaluating successive generations of this technology, particularly in locations with greater environmental extremes, and it encourages their increased use by the Navy.

  20. Prototypical Rod Construction Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 3 discusses the following topics: Downender Test Results and Analysis Report; NFBC Canister Upender Test Results and Analysis Report; Fuel Assembly Handling Fixture Test Results and Analysis Report; and Fuel Canister Upender Test Results and Analysis Report

  1. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 4 of Volume IV, discusses: Off-normal operating and recovery procedures; Emergency response procedures; Troubleshooting procedures; and Preventive maintenance procedures

  2. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  3. Nano-immunosafety: issues in assay validation

    International Nuclear Information System (INIS)

    Boraschi, Diana; Italiani, Paola; Oostingh, Gertie J; Duschl, Albert; Casals, Eudald; Puntes, Victor F; Nelissen, Inge

    2011-01-01

    Assessing the safety of engineered nanomaterials for human health must include a thorough evaluation of their effects on the immune system, which is responsible for defending the integrity of our body from damage and disease. An array of robust and representative assays should be set up and validated, which could be predictive of the effects of nanomaterials on immune responses. In a trans-European collaborative work, in vitro assays have been developed to this end. In vitro tests have been preferred for their suitability to standardisation and easier applicability. Adapting classical assays to testing the immunotoxicological effects of nanoparticulate materials has raised a series of issues that needed to be appropriately addressed in order to ensure reliability of results. Besides the exquisitely immunological problem of selecting representative endpoints predictive of the risk of developing disease, assay results turned out to be significantly biased by artefactual interference of the nanomaterials or contaminating agents with the assay protocol. Having addressed such problems, a series of robust and representative assays have been developed that describe the effects of engineered nanoparticles on professional and non-professional human defence cells. Two of such assays are described here, one based on primary human monocytes and the other employing human lung epithelial cells transfected with a reporter gene.

  4. Radioactive wastes assay technique and equipment

    International Nuclear Information System (INIS)

    Lee, K. M.; Hong, D. S; Kim, T. K.; Bae, S. M.; Shon, J. S.; Hong, K. P.

    2004-12-01

    The waste inventory records such as the activities and radio- nuclides contained in the waste packages are to be submitted with the radioactive wastes packages for the final disposal. The nearly around 10,000 drums of waste stocked in KAERI now should be assayed for the preparation of the waste inventory records too. For the successive execution of the waste assay, the investigation into the present waste assay techniques and equipment are to be taken first. Also the installation of the waste assay equipment through the comprehensive design, manufacturing and procurement should be proceeded timely. As the characteristics of the KAERI-stocked wastes are very different from that of the nuclear power plant and those have no regular waste streams, the application of the in-direct waste assay method using the scaling factors are not effective for the KAERI-generated wastes. Considering for the versal conveniency including the accuracy over the wide range of waste forms and the combination of assay time and sensitivity, the TGS(Tomographic Gamma Scanner) is appropriate as for the KAERI -generated radioactive waste assay equipment

  5. A multiwell format assay for heparanase.

    Science.gov (United States)

    Behzad, Farhad; Brenchley, Paul E C

    2003-09-15

    This assay employs a biotinylated heparan sulfate glycosaminoglycan (HSGAG) substrate that is covalently linked to the surface of 96-well immunoassay plates. The ratio of biotin:HSGAG and the coating concentration of substrate bound to the wells have been optimized and allow removal of biotin HSGAG within 60 min of incubation at 37 degrees C in assay buffer with a standard dilution of bacterial heparitinase or platelet heparanase. Loss of biotin signal from the well surface is detected on incubation with peroxidase-streptavidin followed by color development using 3,3',5,5'-tetramethylbenzidine as the peroxidase substrate. The new assay allows specific detection of heparanase activity in multiple samples in a total time of 3 h including a 1-h substrate digestion step and is a significant improvement with regard to sensitivity, specificity, and ease of handling of multiple samples compared to other described assays. Heparanase specifically degrades the biotinylated HSGAG substrate, when used with an optimized assay buffer. A range of enzymes including collagenase, trypsin, plasmin, pepsin, chondroitinases, hyaluronidase, and neuraminidase show no effect on the substrate under optimized assay conditions. The covalent linkage of the substrate to the well prevents leaching of substrate and allows preparation and long-term storage of substrate-coated plates. The assay can be used to detect heparanase levels in clinical samples and cell culture supernatants and is ideal as a screening method for antagonists of enzyme activity.

  6. Demonstration of Data Interactive Publications

    Science.gov (United States)

    Domenico, B.; Weber, J.

    2012-04-01

    This is a demonstration version of the talk given in session ESSI2.4 "Full lifecycle of data." For some years now, the authors have developed examples of online documents that allowed the reader to interact directly with datasets, but there were limitations that restricted the interaction to specific desktop analysis and display tools that were not generally available to all readers of the documents. Recent advances in web service technology and related standards are making it possible to develop systems for publishing online documents that enable readers to access, analyze, and display the data discussed in the publication from the perspective and in the manner from which the author wants it to be represented. By clicking on embedded links, the reader accesses not only the usual textual information in a publication, but also data residing on a local or remote web server as well as a set of processing tools for analyzing and displaying the data. With the option of having the analysis and display processing provided on the server (or in the cloud), there are now a broader set of possibilities on the client side where the reader can interact with the data via a thin web client, a rich desktop application, or a mobile platform "app." The presentation will outline the architecture of data interactive publications along with illustrative examples.

  7. Demonstration poloidal coil test facility

    International Nuclear Information System (INIS)

    Sato, Masahiko; Kawano, Katumi; Tada, Eisuke

    1989-01-01

    A new compact cryogenic cold compressor was developed by Japan Atomic Energy Research Institute (JAERI) in collaboration with Isikawajima-Harima Heavy Industries Co., Ltd. (IHI) in order to produce the supercritical helium below 4.2 K for Demonstration Poloidal Coils (DPC) which are forced-flow cooled type superconducting pulse coils. This compressor is one of key components for DPC test facility. The cold compressor reduces pressure in liquid helium bath, which contains liquid helium of around 3,000 l, down to 0.5 atm efficiently. Consequently, supercritical helium down to 3.5 K is produced and supplied to the DPC coils. A centrifugal compressor with dynamic gas bearing is selected as a compressor mechanism to realize high adiabatic efficiency and large flow rate. In this performance tests, the compressor was operated for 220 h at saturated condition from 0.5 to 1.0 atm without any failure. High adiabatic efficiency (more than 60 %) is achieved with wide flow range (25-65 g/s) and the design value is fully satisfied. The compressor can rotate up to 80,000 rpm at maximum then the coil supply temperature of supercritical helium is 3.5 K. (author)

  8. Demonstration of superconducting micromachined cavities

    Energy Technology Data Exchange (ETDEWEB)

    Brecht, T., E-mail: teresa.brecht@yale.edu; Reagor, M.; Chu, Y.; Pfaff, W.; Wang, C.; Frunzio, L.; Devoret, M. H.; Schoelkopf, R. J. [Department of Applied Physics, Yale University, New Haven, Connecticut 06511 (United States)

    2015-11-09

    Superconducting enclosures will be key components of scalable quantum computing devices based on circuit quantum electrodynamics. Within a densely integrated device, they can protect qubits from noise and serve as quantum memory units. Whether constructed by machining bulk pieces of metal or microfabricating wafers, 3D enclosures are typically assembled from two or more parts. The resulting seams potentially dissipate crossing currents and limit performance. In this letter, we present measured quality factors of superconducting cavity resonators of several materials, dimensions, and seam locations. We observe that superconducting indium can be a low-loss RF conductor and form low-loss seams. Leveraging this, we create a superconducting micromachined resonator with indium that has a quality factor of two million, despite a greatly reduced mode volume. Inter-layer coupling to this type of resonator is achieved by an aperture located under a planar transmission line. The described techniques demonstrate a proof-of-principle for multilayer microwave integrated quantum circuits for scalable quantum computing.

  9. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 4 discusses the following topics: Rod Compaction/Loading System Test Results and Analysis Report; Waste Collection System Test Results and Analysis Report; Waste Container Transfer Fixture Test Results and Analysis Report; Staging and Cutting Table Test Results and Analysis Report; and Upper Cutting System Test Results and Analysis Report

  10. Dynamic underground stripping demonstration project

    International Nuclear Information System (INIS)

    Newmark, R.L.

    1992-04-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation techniques for rapid cleanup of localized underground spills. Called dynamic stripping to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first eight months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques. Tests then began on the contaminated site in FY 1992. This report describes the work at the Clean Site, including design and performance criteria, test results, interpretations, and conclusions. We fielded 'a wide range of new designs and techniques, some successful and some not. In this document, we focus on results and performance, lessons learned, and design and operational changes recommended for work at the contaminated site. Each section focuses on a different aspect of the work and can be considered a self-contained contribution

  11. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 5 discusses the following topics: Lower Cutting System Test Results and Analysis Report; NFBC Loading System Test Results and Analysis Report; Robotic Bridge Transporter Test Results and Analysis Report; RM-10A Remotec Manipulator Test Results and Analysis Report; and Manipulator Transporter Test Results and Analysis Report

  12. Ionosphere Waves Service - A demonstration

    Science.gov (United States)

    Crespon, François

    2013-04-01

    In the frame of the FP7 POPDAT project the Ionosphere Waves Service was developed by ionosphere experts to answer several questions: How make the old ionosphere missions more valuable? How provide scientific community with a new insight on wave processes that take place in the ionosphere? The answer is a unique data mining service accessing a collection of topical catalogues that characterize a huge number of Atmospheric Gravity Waves, Travelling Ionosphere Disturbances and Whistlers events. The Ionosphere Waves Service regroups databases of specific events extracted by experts from a ten of ionosphere missions which end users can access by applying specific searches and by using statistical analysis modules for their domain of interest. The scientific applications covered by the IWS are relative to earthquake precursors, ionosphere climatology, geomagnetic storms, troposphere-ionosphere energy transfer, and trans-ionosphere link perturbations. In this presentation we propose to detail the service design, the hardware and software architecture, and the service functions. The service interface and capabilities will be the focus of a demonstration in order to help potential end-users for their first access to the Ionosphere Waves Service portal. This work is made with the support of FP7 grant # 263240.

  13. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  14. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  15. The multicenter study of a new assay for simultaneous detection of multiple anti-aminoacyl-tRNA synthetases in myositis and interstitial pneumonia.

    Directory of Open Access Journals (Sweden)

    Ran Nakashima

    Full Text Available OBJECTIVE: Autoantibodies to aminoacyl-tRNA synthetases (ARSs are useful in the diagnosis of idiopathic inflammatory myopathy (IIM with interstitial pneumonia (IP. We developed an enzyme-linked immunosorbent assay (ELISA system using a mixture of recombinant ARS antigens and tested its utility in a multicenter study. METHODS: We prepared six recombinant ARSs: GST-Jo-1, His-PL-12, His-EJ and GST-KS expressed in Escherichia coli, and His-PL-7 and His-OJ expressed in Hi-5 cells. After confirming their antigenic activity, with the exception of His-OJ, we developed our ELISA system in which the five recombinant ARSs (without His-OJ were mixed. Efficiency was confirmed using the sera from 526 Japanese patients with connective tissue disease (CTD (IIM n = 250, systemic lupus erythematosus n = 91, systemic sclerosis n = 70, rheumatoid arthritis n = 75, Sjögren's syndrome n = 27 and other diseases n = 13, 168 with idiopathic interstitial pneumonia (IIP and 30 healthy controls collected from eight institutes. IIPs were classified into two groups; idiopathic pulmonary fibrosis (IPF (n = 38 and non-IPF (n = 130. RESULTS were compared with those of RNA immunoprecipitation. RESULTS: Sensitivity and specificity of the ELISA were 97.1% and 99.8%, respectively when compared with the RNA immunoprecipitation assay. Anti-ARS antibodies were detected in 30.8% of IIM, 2.5% of non-myositis CTD, and 10.7% of IIP (5.3% of IPF and 12.3% of non-IPF. Anti-ARS-positive non-IPF patients were younger and more frequently treated with glucocorticoids and/or immunosuppressants than anti-ARS-negative patients. CONCLUSION: A newly established ELISA detected anti-ARS antibodies as efficiently as RNA immunoprecipitation. This system will enable easier and wider use in the detection of anti-ARS antibodies in patients with IIM and IIP.

  16. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lee, R. Stephen; Ottmar, Herbert; Guardini, Sergio

    1999-01-01

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants [ru

  17. Thermometric enzyme linked immunosorbent assay: TELISA.

    Science.gov (United States)

    Mattiasson, B; Borrebaeck, C; Sanfridson, B; Mosbach, K

    1977-08-11

    A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.

  18. High throughput comet assay to study genotoxicity of nanomaterials

    Directory of Open Access Journals (Sweden)

    Naouale El Yamani

    2015-06-01

    per slide. Subsequent incubation with FPG revealed damage not seen with the basic assay for strand breaks (without FPG (Harris et al., 2015. Statistical evaluation showed that oleic acid coated Fe3O4 and TiO2 NMs are genotoxic, in the experimental conditions used. No differences were seen between cell lines representing a range of different tissues – demonstrating the general usefulness of in vitro models and the ability of cells to classify NMs as genotoxic and non-genotoxic (Cowie et al., 2015. We are currently studying the effects of 20 NMs in the NANoREG project using A549, BEAS B2 and TK6 cells - again demonstrating the usefulness of the HTP comet assay for nanogenotoxicity testing.

  19. A reporter system for replication-competent gammaretroviruses: the inGluc-MLV-DERSE assay

    Science.gov (United States)

    Aloia, Amanda L.; Duffy, Lisa; Pak, Vladimir; Lee, KyeongEun; Sanchez-Martinez, Silvia; Derse, David; Heidecker, Gisela; Cornetta, Kenneth; Rein, Alan

    2012-01-01

    While novel retroviral vectors for use in gene-therapy products are reducing the potential for formation of replication-competent retrovirus (RCR), it remains crucial to screen products for RCR for both research and clinical purposes. For clinical grade gammaretrovirus-based vectors, RCR screening is achieved by an extended S+L− or marker rescue assay, while standard methods for replication-competent lentivirus detection are still in development. In this report, we describe a rapid and sensitive method for replication-competent gammaretrovirus detection. We used this assay to detect three members of the gammaretrovirus family and compared the sensitivity of our assay with well-established methods for retrovirus detection, including the extended S+L− assay. Results presented here demonstrate that this assay should be useful for gene-therapy product testing. PMID:22402321

  20. Non-Enzymatic Detection of Bacterial Genomic DNA Using the Bio-Barcode Assay

    Science.gov (United States)

    Hill, Haley D.; Vega, Rafael A.; Mirkin, Chad A.

    2011-01-01

    The detection of bacterial genomic DNA through a non-enzymatic nanomaterials based amplification method, the bio-barcode assay, is reported. The assay utilizes oligonucleotide functionalized magnetic microparticles to capture the target of interest from the sample. A critical step in the new assay involves the use of blocking oligonucleotides during heat denaturation of the double stranded DNA. These blockers bind to specific regions of the target DNA upon cooling, and prevent the duplex DNA from re-hybridizing, which allows the particle probes to bind. Following target isolation using the magnetic particles, oligonucleotide functionalized gold nanoparticles act as target recognition agents. The oligonucleotides on the nanoparticle (barcodes) act as amplification surrogates. The barcodes are then detected using the Scanometric method. The limit of detection for this assay was determined to be 2.5 femtomolar, and this is the first demonstration of a barcode type assay for the detection of double stranded, genomic DNA. PMID:17927207

  1. Magnetic Launch Assist Demonstration Test

    Science.gov (United States)

    2001-01-01

    This image shows a 1/9 subscale model vehicle clearing the Magnetic Launch Assist System, formerly referred to as the Magnetic Levitation (MagLev), test track during a demonstration test conducted at the Marshall Space Flight Center (MSFC). Engineers at MSFC have developed and tested Magnetic Launch Assist technologies. To launch spacecraft into orbit, a Magnetic Launch Assist System would use magnetic fields to levitate and accelerate a vehicle along a track at very high speeds. Similar to high-speed trains and roller coasters that use high-strength magnets to lift and propel a vehicle a couple of inches above a guideway, a launch-assist system would electromagnetically drive a space vehicle along the track. A full-scale, operational track would be about 1.5-miles long and capable of accelerating a vehicle to 600 mph in 9.5 seconds. This track is an advanced linear induction motor. Induction motors are common in fans, power drills, and sewing machines. Instead of spinning in a circular motion to turn a shaft or gears, a linear induction motor produces thrust in a straight line. Mounted on concrete pedestals, the track is 100-feet long, about 2-feet wide and about 1.5-feet high. The major advantages of launch assist for NASA launch vehicles is that it reduces the weight of the take-off, the landing gear, the wing size, and less propellant resulting in significant cost savings. The US Navy and the British MOD (Ministry of Defense) are planning to use magnetic launch assist for their next generation aircraft carriers as the aircraft launch system. The US Army is considering using this technology for launching target drones for anti-aircraft training.

  2. Coal ash artificial reef demonstration

    International Nuclear Information System (INIS)

    Livingston, R.J.; Brendel, G.F.; Bruzek, D.A.

    1991-01-01

    This experimental project evaluated the use of coal ash to construct artificial reefs. An artificial reef consisting of approximately 33 tons of cement-stabilized coal ash blocks was constructed in approximately 20 feet of water in the Gulf of Mexico approximately 9.3 miles west of Cedar Key, Florida. The project objectives were: (1) demonstrate that a durable coal ash/cement block can be manufactured by commercial block-making machines for use in artificial reefs, and (2) evaluate the possibility that a physically stable and environmentally acceptable coal ash/cement block reef can be constructed as a means of expanding recreational and commercial fisheries. The reef was constructed in February 1988 and biological surveys were made at monthly intervals from May 1988 to April 1989. The project provided information regarding: Development of an optimum design mix, block production and reef construction, chemical composition of block leachate, biological colonization of the reef, potential concentration of metals in the food web associated with the reef, acute bioassays (96-hour LC 50 ). The Cedar Key reef was found to be a habitat that was associated with a relatively rich assemblage of plants and animals. The reef did not appear to be a major source of heavy metals to species at various levels of biological organization. GAI Consultants, Inc (GAI) of Monroeville, Pennsylvania was the prime consultant for the project. The biological monitoring surveys and evaluations were performed by Environmental Planning and Analysis, Inc. of Tallahassee, Florida. The chemical analyses of biological organisms and bioassay elutriates were performed by Savannah Laboratories of Tallahassee, Florida. Florida Power Corporation of St. Petersburg, Florida sponsored the project and supplied ash from their Crystal River Energy Complex

  3. Premarket evaluations of the IMDx C. difficile for Abbott m2000 Assay and the BD Max Cdiff Assay.

    Science.gov (United States)

    Stellrecht, K A; Espino, A A; Maceira, V P; Nattanmai, S M; Butt, S A; Wroblewski, D; Hannett, G E; Musser, K A

    2014-05-01

    Clostridium difficile-associated diarrhea is a well-recognized complication of antibiotic use. Historically, diagnosing C. difficile has been difficult, as antigen assays are insensitive and culture-based methods require several days to yield results. Nucleic acid amplification tests (NAATs) are quickly becoming the standard of care. We compared the performance of two automated investigational/research use only (IUO/RUO) NAATs for the detection of C. difficile toxin genes, the IMDx C. difficile for Abbott m2000 Assay (IMDx) and the BD Max Cdiff Assay (Max). A prospective analysis of 111 stool specimens received in the laboratory for C. difficile testing by the laboratory's test of record (TOR), the BD GeneOhm Cdiff Assay, and a retrospective analysis of 88 specimens previously determined to be positive for C. difficile were included in the study. One prospective specimen was excluded due to loss to follow-up discrepancy analysis. Of the remaining 198 specimens, 90 were positive by all three methods, 9 were positive by TOR and Max, and 3 were positive by TOR only. One negative specimen was initially inhibitory by Max. The remaining 95 specimens were negative by all methods. Toxigenic C. difficile culture was performed on the 12 discrepant samples. True C. difficile-positive status was defined as either positive by all three amplification assays or positive by toxigenic culture. Based on this definition, the sensitivity and specificity were 96.9% and 95% for Max and 92.8% and 100% for IMDx. In summary, both highly automated systems demonstrated excellent performance, and each has individual benefits, which will ensure that they will both have a niche in clinical laboratories.

  4. Split Beta-Lactamase Complementation Assay

    Indian Academy of Sciences (India)

    IAS Admin

    A Search for the Molecular Better Half! Vaishali Verma ... These assays comprise of a protein molecule, ... ciferase, beta-galactosidase, GFP, g3p of M13 filamentous ph- .... sensors of protein–protein interactions, Nature Biotechnology, Vol.20,.

  5. Linearization of the bradford protein assay.

    Science.gov (United States)

    Ernst, Orna; Zor, Tsaffrir

    2010-04-12

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.

  6. 21 CFR 866.3210 - Endotoxin assay.

    Science.gov (United States)

    2010-04-01

    ... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3210 Endotoxin assay. (a... intended for use in conjunction with other laboratory findings and clinical assessment of the patient to...

  7. Evaluation of the Thermo Scientific SureTect Listeria monocytogenes Assay.

    Science.gov (United States)

    Cloke, Jonathan; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Hopper, Craig; Simpson, Helen; Withey, Sophie; Oleksiuk, Milena; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Listeria monocytogenes Assay is a new real-time PCR assay for the detection of Listeria monocytogenes in food and environmental samples. This assay was validated using the AOAC Research Institute (AOAC-RI) Performance Tested Methods program in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996, including Amendment 1:2004 with the following foods and food contact surfaces: smoked salmon, processed cheese, fresh bagged spinach, fresh cantaloupe, cooked prawns (chilled product), cooked sliced turkey meat (chilled product), ice cream, pork frankfurters, salami, ground raw beef meat (12% fat), plastic, and stainless steel. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, bagged lettuce, and stainless steel) were analyzed independently as part of the AOAC-RI controlled laboratory study by the University of Guelph, Canada. Using probability of detection (POD) statistical analysis, a significant difference was demonstrated between the candidate and reference methods for salami, cooked sliced turkey and ice cream in favor of the SureTect assay. For all other matrixes, no significant difference by POD was seen between the two methods during the study. Inclusivity and exclusivity testing was also conducted with 53 and 30 isolates, respectively, which demonstrated that the SureTect assay was able to detect all serotypes of L. monocytogenes. None of the exclusivity isolates analyzed were detected by the SureTect assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside the recommended parameters open to variation, i.e., enrichment time and temperature and lysis temperature, which demonstrated that the assay gave reliable performance. Accelerated stability testing was also conducted, validating the assay shelf life.

  8. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    Science.gov (United States)

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  9. Passive nondestructive assay of nuclear materials

    International Nuclear Information System (INIS)

    Reilly, D.; Ensslin, N.; Smith, H. Jr.; Kreiner, S.

    1991-03-01

    The term nondestructive assay (NDA) is applied to a series of measurement techniques for nuclear fuel materials. The techniques measure radiation induced or emitted spontaneously from the nuclear material; the measurements are nondestructive in that they do not alter the physical or chemical state of the nuclear material. NDA techniques are characterized as passive or active depending on whether they measure radiation from the spontaneous decay of the nuclear material or radiation induced by an external source. This book emphasizes passive NDA techniques, although certain active techniques like gamma-ray absorption densitometry and x-ray fluorescence are discussed here because of their intimate relation to passive assay techniques. The principal NDA techniques are classified as gamma-ray assay, neutron assay, and calorimetry. Gamma-ray assay techniques are treated in Chapters 1--10. Neutron assay techniques are the subject of Chapters 11--17. Chapters 11--13 cover the origin of neutrons, neutron interactions, and neutron detectors. Chapters 14--17 cover the theory and applications of total and coincidence neutron counting. Chapter 18 deals with the assay of irradiated nuclear fuel, which uses both gamma-ray and neutron assay techniques. Chapter 19 covers perimeter monitoring, which uses gamma-ray and neutron detectors of high sensitivity to check that no unauthorized nuclear material crosses a facility boundary. The subject of Chapter 20 is attribute and semiquantitative measurements. The goal of these measurements is a rapid verification of the contents of nuclear material containers to assist physical inventory verifications. Waste and holdup measurements are also treated in this chapter. Chapters 21 and 22 cover calorimetry theory and application, and Chapter 23 is a brief application guide to illustrate which techniques can be used to solve certain measurement problems

  10. Optical assay for biotechnology and clinical diagnosis.

    Science.gov (United States)

    Moczko, Ewa; Cauchi, Michael; Turner, Claire; Meglinski, Igor; Piletsky, Sergey

    2011-08-01

    In this paper, we present an optical diagnostic assay consisting of a mixture of environmental-sensitive fluorescent dyes combined with multivariate data analysis for quantitative and qualitative examination of biological and clinical samples. The performance of the assay is based on the analysis of spectrum of the selected fluorescent dyes with the operational principle similar to electronic nose and electronic tongue systems. This approach has been successfully applied for monitoring of growing cell cultures and identification of gastrointestinal diseases in humans.

  11. Calibration method for a radwaste assay system

    International Nuclear Information System (INIS)

    Dulama, C.; Dobrin, R.; Toma, Al.; Paunoiu, C.

    2004-01-01

    A waste assay system entirely designed and manufactured in the Institute for Nuclear Research is used in radwaste treatment and conditioning stream to ensure compliance with national repository radiological requirements. Usually, waste assay systems are calibrated by using various experimental arrangements including calibration phantoms. The paper presents a comparative study concerning the efficiency calibration performed by shell source method and a semiempirical, computational method based on a Monte Carlo algorithm. (authors)

  12. Evaluation of Myc Gene Amplification in Prostate Cancer Using a Dual Color Chromogenic in-Situ Hybridization (Dual CISH) Assay

    OpenAIRE

    Daniel Lerda; Marta Cabrera; Jorge Flores; Luis Gutierrez; Armando Chierichetti; Martin Revol; Hernan Garcia Onto

    2013-01-01

    Objetive: The overall purpose of the study was to demonstrate applicability of the Dako dual-color chromogenic in situ hybridization (CISH) assay (DAKO Denmark, Glostrup) with respect to fluorescence in situ hybridization (FISH) probes MYC-C. Methods: MYC gene amplification by FISH and Dako dual-color CISH Results: The study showed that the dual-color CISH assay can convert Texas red and fluorescein isothiocyanate (FITC) signals into chromogenic signals. The dual –color CISH assay was p...

  13. Radioimmune assay of human platelet prostaglandin synthetase

    International Nuclear Information System (INIS)

    Roth, G.J.; Machuga, E.T.

    1982-01-01

    Normal platelet function depends, in part, on platelet PG synthesis. PG synthetase (cyclo-oxygenase) catalyzes the first step in PG synthesis, the formation of PGH 2 from arachidonic acid. Inhibition of the enzyme by ASA results in an abnormality in the platelet release reaction. Patients with pparent congenital abnormalities in the enzyme have been described, and the effects have been referred to as ''aspirin-like'' defects of the platelet function. These patients lack platelet PG synthetase activity, but the actual content of PG synthetase protein in these individuals' platelets is unknown. Therefore an RIA for human platelet PG synthetase would provide new information, useful in assessing the aspirin-like defects of platelet function. An RIA for human platelet PG synthetase is described. The assay utilizes a rabbit antibody directed against the enzyme and [ 125 I]-labelled sheep PG synthetase as antigen. The human platelet enzyme is assayed by its ability to inhibit precipitation of the [ 125 I]antigen. The assay is sensitive to 1 ng of enzyme. By the immune assay, human platelets contain approximately 1200 ng of PG synethetase protein per 1.5 mg of platelet protein (approximately 10 9 platelets). This content corresponds to 10,000 enzyme molecules per platelet. The assay provides a rapid and convenient assay for the human platelet enzyme, and it can be applied to the assessment of patients with apparent platelet PG synthetase (cyclo-oxygenase) deficiency

  14. Nondestructive assay methods for irradiated nuclear fuels

    International Nuclear Information System (INIS)

    Hsue, S.T.; Crane, T.W.; Talbert, W.L. Jr.; Lee, J.C.

    1978-01-01

    This report is a review of the status of nondestructive assay (NDA) methods used to determine burnup and fissile content of irradiated nuclear fuels. The gamma-spectroscopy method measures gamma activities of certain fission products that are proportional to the burnup. Problems associated with this method are migration of the fission products and gamma-ray attenuation through the relatively dense fuel material. The attenuation correction is complicated by generally unknown activity distributions within the assemblies. The neutron methods, which usually involve active interrogation and prompt or delayed signal counting, are designed to assay the fissile content of the spent-fuel elements. Systems to assay highly enriched spent-fuel assemblies have been tested extensively. Feasibility studies have been reported of systems to assay light-water reactor spent-fuel assemblies. The slowing-down spectrometer and neutron resonance absorption methods can distinguish between the uranium and plutonium fissile contents, but they are limited to the assay of individual rods. We have summarized the status of NDA techniques for spent-fuel assay and present some subjects in need of further investigation. Accuracy of the burnup calculations for power reactors is also reviewed

  15. Temperature Switch PCR (TSP: Robust assay design for reliable amplification and genotyping of SNPs

    Directory of Open Access Journals (Sweden)

    Mather Diane E

    2009-12-01

    Full Text Available Abstract Background Many research and diagnostic applications rely upon the assay of individual single nucleotide polymorphisms (SNPs. Thus, methods to improve the speed and efficiency for single-marker SNP genotyping are highly desirable. Here, we describe the method of temperature-switch PCR (TSP, a biphasic four-primer PCR system with a universal primer design that permits amplification of the target locus in the first phase of thermal cycling before switching to the detection of the alleles. TSP can simplify assay design for a range of commonly used single-marker SNP genotyping methods, and reduce the requirement for individual assay optimization and operator expertise in the deployment of SNP assays. Results We demonstrate the utility of TSP for the rapid construction of robust and convenient endpoint SNP genotyping assays based on allele-specific PCR and high resolution melt analysis by generating a total of 11,232 data points. The TSP assays were performed under standardised reaction conditions, requiring minimal optimization of individual assays. High genotyping accuracy was verified by 100% concordance of TSP genotypes in a blinded study with an independent genotyping method. Conclusion Theoretically, TSP can be directly incorporated into the design of assays for most current single-marker SNP genotyping methods. TSP provides several technological advances for single-marker SNP genotyping including simplified assay design and development, increased assay specificity and genotyping accuracy, and opportunities for assay automation. By reducing the requirement for operator expertise, TSP provides opportunities to deploy a wider range of single-marker SNP genotyping methods in the laboratory. TSP has broad applications and can be deployed in any animal and plant species.

  16. An eDNA Assay to Monitor a Globally Invasive Fish Species from Flowing Freshwater.

    Science.gov (United States)

    Adrian-Kalchhauser, Irene; Burkhardt-Holm, Patricia

    2016-01-01

    Ponto-Caspian gobies are a flock of five invasive fish species that have colonized freshwaters and brackish waters in Europe and North America. One of them, the round goby Neogobius melanostomus, figures among the 100 worst invaders in Europe. Current methods to detect the presence of Ponto-Caspian gobies involve catching or sighting the fish. These approaches are labor intense and not very sensitive. Consequently, populations are usually detected only when they have reached high densities and when management or containment efforts are futile. To improve monitoring, we developed an assay based on the detection of DNA traces (environmental DNA, or eDNA) of Ponto-Caspian gobies in river water. The assay specifically detects invasive goby DNA and does not react to any native fish species. We apply the assay to environmental samples and demonstrate that parameters such as sampling depth, sampling location, extraction protocol, PCR protocol and PCR inhibition greatly impact detection. We further successfully outline the invasion front of Ponto-Caspian gobies in a large river, the High Rhine in Switzerland, and thus demonstrate the applicability of the assay to lotic environments. The eDNA assay requires less time, equipment, manpower, skills, and financial resources than the conventional monitoring methods such as electrofishing, angling or diving. Samples can be taken by untrained individuals, and the assay can be performed by any molecular biologist on a conventional PCR machine. Therefore, this assay enables environment managers to map invaded areas independently of fishermen's' reports and fish community monitorings.

  17. Nondestructive assay of subassemblies of various spent or fresh fuels by active neutron interrogation

    International Nuclear Information System (INIS)

    Ragan, G.L.; Ricker, C.W.; Chiles, M.M.; Ingersoll, D.T.; Slaughter, G.G.

    1979-01-01

    Recent studies show that subassemblies containing various spent fuels could be assayed rapidly and accurately by a nondestructive assay system using active neutron interrogation and prompt-neutron detection. Subassembly penetration is achieved by 24-keV (Sb--Be) interrogation neutrons; the spent-fuel neutron background is overridden by using strong interrogating sources and prompt-neutron signals, and background gammas are absorbed by lead. Experiments have demonstrated the potential for assaying with better than 5% accuracy, three spent plutonium-fueled subassemblies per hour. Calculations, validated by experiments, predict even better performance for fresh or uranium-fueled subassemblies; several performance estimates are given

  18. Enzyme activity assays within microstructured optical fibers enabled by automated alignment.

    Science.gov (United States)

    Warren-Smith, Stephen C; Nie, Guiying; Schartner, Erik P; Salamonsen, Lois A; Monro, Tanya M

    2012-12-01

    A fluorescence-based enzyme activity assay has been demonstrated within a small-core microstructured optical fiber (MOF) for the first time. To achieve this, a reflection-based automated alignment system has been developed, which uses feedback and piezoelectric actuators to maintain optical alignment. The auto-alignment system provides optical stability for the time required to perform an activity assay. The chosen assay is based on the enzyme proprotein convertase 5/6 (PC6) and has important applications in women's health.

  19. Reducing the Noise in Behavioral Assays: Sex and Age in Adult Zebrafish Locomotion

    OpenAIRE

    Philpott, Catelyn; Donack, Corey J.; Cousin, Margot A.; Pierret, Chris

    2012-01-01

    Many assays are used in animal model systems to measure specific human disease-related behaviors. The use of both adult and larval zebrafish as a behavioral model is gaining popularity. As this work progresses and potentially translates into new treatments, we must do our best to improve the sensitivity of these assays by reducing confounding factors. Scientists who use the mouse model system have demonstrated that sex and age can influence a number of behaviors. As a community, they have mov...

  20. Assay of fluconazole by high-performance liquid chromatography with a mixed-phase column.

    OpenAIRE

    Wallace, J E; Harris, S C; Gallegos, J; Foulds, G; Chen, T J; Rinaldi, M G

    1992-01-01

    A mixed-phase liquid chromatographic column was used to assay fluconazole in plasma, serum, and cerebrospinal fluid. The assay was linear from 0.2 to 20 micrograms/ml, with an average coefficient of variation of less than 5%. The partitioning of the drug between serum and cerebrospinal fluid was determined for 34 patients. The method was demonstrated to be suitable for both pharmacokinetic studies and monitoring of patients receiving treatment with this antifungal agent.

  1. A radiobiological comparison of human tumor soft-agar clonogenic assays.

    Science.gov (United States)

    West, C M; Sutherland, R M

    1986-06-15

    Radiation survival curves have been generated for 3 human tumor cell lines as a means of comparing and evaluating the validity of human tumor soft-agar clonogenic assays. The assays investigated were the Hamburger-Salmon, Courtenay-Mills, Courtenay-Mills plus additions, soft agar (no additions), and soft agar plus additions. The additions were formulated to supplement the media used in soft agar assays of primary ovarian and cervical carcinoma specimens. Supplementing the media with additions led to a 2- to 3-fold increase in PE of CaSki cells but had no effect on the PEs of ME180 and OWI cells. Radiation survival curves were similar in all assays for CaSki and OWI but differed for ME180 cells. For ME180 cells, the Courtenay-Mills and soft agar assays plus additions produced the most radioresistant curves (Do = 2.2 Gy); the cells were more responsive when assayed by the Hamburger-Salmon method (Do = 1.5 Gy), and the soft agar and Courtenay-Mills assays gave the most radiosensitive curves (Do = 1.2 Gy). These results demonstrate that the PE of human tumor cell lines may be increased with no effect on radiation survival; radiation survival may be altered without changes in PE and neither may be altered by applying modifications and supplements to existing clonogenic assays.

  2. A High Sensitivity Micro Format Chemiluminescence Enzyme Inhibition Assay for Determination of Hg(II

    Directory of Open Access Journals (Sweden)

    Kanchanmala Deshpande

    2010-06-01

    Full Text Available A highly sensitive and specific enzyme inhibition assay based on alcohol oxidase (AlOx and horseradish peroxidase (HRP for determination of mercury Hg(II in water samples has been presented. This article describes the optimization and miniaturization of an enzymatic assay using a chemiluminescence reaction. The analytical performance and detection limit for determination of Hg(II was optimized in 96 well plates and further extended to 384 well plates with a 10-fold reduction in assay volume. Inhibition of the enzyme activity by dissolved Hg(II was found to be linear in the range 5–500 pg.mL−1 with 3% CVin inter-batch assay. Due to miniaturization of assay in 384 well plates, Hg(II was measurable as low as 1 pg.mL−1 within15 min. About 10-fold more specificity of the developed assay for Hg(II analysis was confirmed by challenging with interfering divalent metal ions such as cadmium Cd(II and lead Pb(II. Using the proposed assay we could successfully demonstrate that in a composite mixture of Hg(II, Cd(II and Pb(II, inhibition by each metal ion is significantly enhanced in the presence of the others. Applicability of the proposed assay for the determination of the Hg(II in spiked drinking and sea water resulted in recoveries ranging from 100–110.52%.

  3. Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.

    Science.gov (United States)

    Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo

    2018-05-01

    Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. A Forceful Demonstration by FORS

    Science.gov (United States)

    1998-09-01

    .). In addition, detailed computer software was provided to prepare the complex astronomical observations with FORS in advance and to monitor the instrument performance by quality checks of the scientific data accumulated. In return for building FORS for the community of European astrophysicists, the scientists in the three institutions of the FORS Consortium have received a certain amount of Guaranteed Observing Time at the VLT. This time will be used for various research projects concerned, among others, with minor bodies in the outer solar system, stars at late stages of their evolution and the clouds of gas they eject, as well as galaxies and quasars at very large distances, thereby permitting a look-back towards the early epoch of the universe. First tests of FORS1 at the VLT UT1: a great success After careful preparation, the FORS consortium has now started the so-called commissioning of the instrument. This comprises the thorough verification of the specified instrument properties at the telescope, checking the correct functioning under software control from the Paranal control room and, at the end of this process, a demonstration that the instrument fulfills its scientific purpose as planned. While performing these tests, the commissioning team at Paranal were able to obtain images of various astronomical objects, some of which are shown here. Two of these were obtained on the night of "FORS First Light". The photos demonstrate some of the impressive posibilities with this new instrument. They are based on observations with the FORS standard resolution collimator (field size 6.8 x 6.8 armin = 2048 x 2048 pixels; 1 pixel = 0.20 arcsec). Spiral galaxy NGC 1288 ESO PR Photo 37a/98 ESO PR Photo 37a/98 [Preview - JPEG: 800 x 908 pix - 224k] [High-Res - JPEG: 3000 x 3406 pix - 1.5Mb] A colour image of spiral galaxy NGC 1288, obtained on the night of "FORS First Light". The first photo shows a reproduction of a colour composite image of the beautiful spiral galaxy NGC

  5. A multiplex branched DNA assay for parallel quantitative gene expression profiling.

    Science.gov (United States)

    Flagella, Michael; Bui, Son; Zheng, Zhi; Nguyen, Cung Tuong; Zhang, Aiguo; Pastor, Larry; Ma, Yunqing; Yang, Wen; Crawford, Kimberly L; McMaster, Gary K; Witney, Frank; Luo, Yuling

    2006-05-01

    We describe a novel method to quantitatively measure messenger RNA (mRNA) expression of multiple genes directly from crude cell lysates and tissue homogenates without the need for RNA purification or target amplification. The multiplex branched DNA (bDNA) assay adapts the bDNA technology to the Luminex fluorescent bead-based platform through the use of cooperative hybridization, which ensures an exceptionally high degree of assay specificity. Using in vitro transcribed RNA as reference standards, we demonstrated that the assay is highly specific, with cross-reactivity less than 0.2%. We also determined that the assay detection sensitivity is 25,000 RNA transcripts with intra- and interplate coefficients of variance of less than 10% and less than 15%, respectively. Using three 10-gene panels designed to measure proinflammatory and apoptosis responses, we demonstrated sensitive and specific multiplex gene expression profiling directly from cell lysates. The gene expression change data demonstrate a high correlation coefficient (R(2)=0.94) compared with measurements obtained using the single-plex bDNA assay. Thus, the multiplex bDNA assay provides a powerful means to quantify the gene expression profile of a defined set of target genes in large sample populations.

  6. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  7. Dynamic optical tweezers based assay for monitoring early drug resistance

    International Nuclear Information System (INIS)

    Wu, Xiaojing; Zhu, Siwei; Feng, Jie; Zhang, Yuquan; Min, Changjun; Yuan, X-C

    2013-01-01

    In this letter, a dynamic optical tweezers based assay is proposed and investigated for monitoring early drug resistance with Pemetrexed-resistant non-small cell lung cancer (NSCLC) cell lines. The validity and stability of the method are verified experimentally in terms of the physical parameters of the optical tweezers system. The results demonstrate that the proposed technique is more convenient and faster than traditional techniques when the capability of detecting small variations of the response of cells to a drug is maintained. (letter)

  8. Controlling variation in the comet assay

    Directory of Open Access Journals (Sweden)

    Andrew Richard Collins

    2014-10-01

    Full Text Available Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardising the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of alkaline incubation, and electrophoresis conditions (time, temperature and voltage gradient are particularly important. Even when these are controlled, variation seems to be inevitable. It is helpful to include in experiments reference standards, i.e. cells with a known amount of specific damage to the DNA. They can be aliquots frozen from a single large batch of cells, either untreated (negative controls or treated with, for example, H2O2 or X-rays to induce strand breaks (positive control for the basic assay, or photosensitiser plus light to oxidise guanine (positive control for Fpg- or OGG1-sensitive sites. Reference standards are especially valuable when performing a series of experiments over a long period - for example, analysing samples of white blood cells from a large human biomonitoring trial - to check that the assay is performing consistently, and to identify anomalous results necessitating a repeat experiment. The reference values of tail intensity can also be used to iron out small variations occurring from day to day. We present examples of the use of reference standards in human trials, both within one laboratory and between different laboratories, and describe procedures that can be used to control variation.

  9. Cell Culture Assay for Human Noroviruses [response

    Energy Technology Data Exchange (ETDEWEB)

    Straub, Tim M.; Honer Zu Bentrup, Kerstin; Orosz Coghlan, Patricia; Dohnalkova, Alice; Mayer, Brooke K.; Bartholomew, Rachel A.; Valdez, Catherine O.; Bruckner-Lea, Cindy J.; Gerba, Charles P.; Abbaszadegan, Morteza A.; Nickerson, Cheryl A.

    2007-07-01

    We appreciate the comments provided by Leung et al., in response to our recently published article “In Vitro Cell Culture Infectivity Assay for Human Noroviruses” by Straub et al. (1). The specific aim of our project was to develop an in vitro cell culture infectivity assay for human noroviruses (hNoV) to enhance risk assessments when they are detected in water supplies. Reverse transcription (RT) qualitative or quantitative PCR are the primary assays for waterborne NoV monitoring. However, these assays cannot distinguish between infectious vs. non-infectious virions. When hNoV is detected in water supplies, information provided by our infectivity assay will significantly improve risk assessment models and protect human health, regardless of whether we are propagating NoV. Indeed, in vitro cell culture infectivity assays for the waterborne pathogen Cryptosporidium parvum that supplement approved fluorescent microscopy assays, do not result in amplification of the environmentally resistant hard-walled oocysts (2). However, identification of life cycle stages in cell culture provides evidence of infectious oocysts in a water supply. Nonetheless, Leung et al.’s assertion regarding the suitability of our method for the in vitro propagation of high titers of NoV is valid for the medical research community. In this case, well-characterized challenge pools of virus would be useful for developing and testing diagnostics, therapeutics, and vaccines. As further validation of our published findings, we have now optimized RT quantitative PCR to assess the level of viral production in cell culture, where we are indeed finding significant increases in viral titer. The magnitude and time course of these increases is dependent on both virus strain and multiplicity of infection. We are currently preparing a manuscript that will discuss these findings in greater detail, and the implications this may have for creating viral challenge pools

  10. Application of statistical process control to qualitative molecular diagnostic assays.

    Directory of Open Access Journals (Sweden)

    Cathal P O'brien

    2014-11-01

    Full Text Available Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control. Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply statistical process control to assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater samples with a resultant protracted time to detection. Modelled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of statistical process control to qualitative laboratory data.

  11. Comparison of Six Automated Treponema-Specific Antibody Assays.

    Science.gov (United States)

    Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk

    2016-01-01

    Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  12. A pigeon crop sac radioreceptor assay for prolactin

    International Nuclear Information System (INIS)

    Forsyth, I.A.; Buntin, J.D.; Nicoll, C.S.

    1978-01-01

    Ovine prolactin, labelled with 125 I by either lactoperoxidase or a mild chloramine T method, was bound to receptors from the pigeon crop sac mucosa cells of prolactin-injected pigeons. Binding was demonstrated in a crude homogenate of mucosal cells removed from the crop by scraping and in a subcellular fraction in which 5'- nucleotidase activity was enhanced two- to three-fold. The binding was specific, dependent on time, temperature and the concentration of receptors and had a dissociation constant of 7 x 10 -10 mol/l. The binding capacity of the crop tissue was 71 fmol/mg membrane protein. Nine purified preparations of prolactin from four species were assayed by local pigeon crop sac bioassay and by radioreceptor assay. The two methods were highly correlated (r = 0.934). The regression equation was radioreceptor assay = 1.22 bioassay - 0.18 indicating a 1:1 correspondence between the two methods for prolactin purified from sheep, rat, horse and pig anterior pituitary glands. (author)

  13. Normalization methods in time series of platelet function assays

    Science.gov (United States)

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  14. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Random assay in radioimmunoassay: Feasibility and application compared with batch assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, Hwan Hee; Park, Sohyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear MedicineNational Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice. The coefficients of variation (CVs) of eight standard curves within a single kit were calculated in a CA-125 immunoradiometric assay (IRMA) for the reference of the practically ideal CV of the CA-125 kit. Ten standard curves of 10 kits from 2 prospectively collected lots (pLot) and 85 standard curves of 85 kits from 3 retrospectively collected lots (Lot) were obtained. Additionally, the raw measurement data of both 170 control references and 1123 patients' sera were collected retrospectively between December 2015 and January 2016. A standard curve of the first kit of each lot was used as a master standard curve for a random assay. The CVs of inter-kits were analyzed in each lot, respectively. All raw measurements were normalized by decay and radioactivity. The CA-125 values from control samples and patients' sera were compared using the original batch assay and random assay. In standard curve analysis, the CVs of inter-kits in pLots and Lots were comparable to those within a single kit. The CVs from the random assay with normalization were similar to those from the batch assay in the control samples (CVs % of low/high concentration; Lot1 2.71/1.91, Lot2 2.35/1.83, Lot3 2.83/2.08 vs. Lot1 2.05/1.21, Lot2 1.66/1.48, Lot3 2.41/2.14). The ICCs between the batch assay and random assay using patients' sera were satisfactory (Lot1 1.00, Lot2 0.999, Lot3 1.00). The random assay technique could be successfully applied to the conventional CA-125 IRMA kits. The random assay showed strong agreement with the batch assay. The

  16. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Centaur HBV assays resulted in no change in interpretation of the results. Assay performance was further evaluated using HBV seroconversion panels with comparable or better results when compared to the comparison assays. The performance evaluation data demonstrate that the ADVIA Centaur HBV assays are specific and sensitive automated immunoassays for detection of antigens and antibodies to hepatitis B virus with performance that is comparable to those of currently marketed assays. Additionally, these assays have the advantage of being available on the ADVIA Centaur immunoassay system, which provides for the flexibility of high throughput and full automation.

  17. Comet assay on mice testicular cells

    Directory of Open Access Journals (Sweden)

    Anoop Kumar Sharma

    2015-05-01

    Full Text Available Heritable mutations may result in a variety of adverse outcomes including genetic disease in the offspring. In recent years the focus on germ cell mutagenicity has increased and the “Globally Harmonized System of Classification and Labelling of Chemicals (GHS” has published classification criteria for germ cell mutagens (Speit et al., 2009. The in vivo Comet assay is considered a useful tool for investigating germ cell genotoxicity. In the present study DNA strand breaks in testicular cells of mice were investigated. Different classes of chemicals were tested in order to evaluate the sensitivity of the comet assay in testicular cells. The chemicals included environmentally relevant substances such as Bisphenol A, PFOS and Tetrabrombisphenol A. Statistical power calculations will be presented to aid in the design of future Comet assay studies on testicular cells. Power curves were provided with different fold changes in % tail DNA, different number of cells scored and different number of gels (Hansen et al., 2014. An example is shown in Figure 1. A high throughput version of the Comet assay was used. Samples were scored with a fully automatic comet assay scoring system that provided faster scoring of randomly selected cells.

  18. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  19. Evaluation of three gentamicin serum assay techniques

    International Nuclear Information System (INIS)

    Matzke, G.R.; Gwizdala, C.; Wery, J.; Ferry, D.; Starnes, R.

    1982-01-01

    This investigation was designed to compare the enzyme-modified immunoassay (Syva--EMIT) with a radioimmunoassay (New England Nuclear--RIA) and the radiometric assay (Johnston--BACTEC) to determine the optimal assay for use in our aminoglycoside dosing service. The serum concentration determinations obtained via the three assay methods were analyzed by linear regression analysis. Significant positive correlations were noted between the three assay techniques (p less than 0.005) during both sample collection phases. The coefficients of determination for EMIT vs BACTEC and RIA vs BACTEC were 0.73 and 0.83 during phase 1, respectively, and 0.65 and 0.68 during phase 2, respectively. The slope of the regression lines also varied markedly during the two phases; 0.49 and 0.42 for EMIT and for RIA vs BACTEC, respectively, during phase 1 compound with 1.12 and 0.77, respectively, during phase 2. The differences noted in these relationships during phase 1 and 2 may be related to the alteration of the pH of the control sera utilized in the BACTEC assay. In contrast, RIA vs EMIT regression analysis indicated that existence of a highly significant relationship (p less than 0.0005 and r2 . 0.90). The EMIT technique was the easiest and most accurate for determination of serum gentamicin concentrations, whereas the BACTEC method was judged unacceptable for clinical use

  20. Low-Level Waste Drum Assay Intercomparison Study

    International Nuclear Information System (INIS)

    Greutzmacher, K.; Kuzminski, J.; Myers, S. C.

    2003-01-01

    Nuclear waste assay is an integral element of programs such as safeguards, waste management, and waste disposal. The majority of nuclear waste is packaged in drums and analyzed by various nondestructive assay (NDA) techniques to identify and quantify the radioactive content. Due to various regulations and the public interest in nuclear issues, the analytical results are required to be of high quality and supported by a rigorous Quality Assurance (QA) program. A valuable QA tool is an intercomparison program in which a known sample is analyzed by a number of different facilities. While transuranic waste (TRU) certified NDA teams are evaluated through the Performance Demonstration Program (PDP), low-level waste (LLW) assay specialists have not been afforded a similar opportunity. NDA specialists from throughout the DOE complex were invited to participate in this voluntary drum assay intercomparison study that was organized and facilitated by the Solid Waste Operations and the Safeguards Science and Technology groups at the Los Alamos National Laboratory and by Eberline Services. Each participating NDA team performed six replicate blind measurements of two 55-gallon drums with relatively low-density matrices (a 19.1 kg shredded paper matrix and a 54.4 kg mixed metal, rubber, paper and plastic matrix). This paper presents the results from this study, with an emphasis on discussing the lessons learned as well as desirable follow up programs for the future. The results will discuss the accuracy and precision of the replicate measurements for each NDA team as well as any issues that arose during the effort

  1. Mining Chemical Activity Status from High-Throughput Screening Assays

    KAUST Repository

    Soufan, Othman

    2015-12-14

    High-throughput screening (HTS) experiments provide a valuable resource that reports biological activity of numerous chemical compounds relative to their molecular targets. Building computational models that accurately predict such activity status (active vs. inactive) in specific assays is a challenging task given the large volume of data and frequently small proportion of active compounds relative to the inactive ones. We developed a method, DRAMOTE, to predict activity status of chemical compounds in HTP activity assays. For a class of HTP assays, our method achieves considerably better results than the current state-of-the-art-solutions. We achieved this by modification of a minority oversampling technique. To demonstrate that DRAMOTE is performing better than the other methods, we performed a comprehensive comparison analysis with several other methods and evaluated them on data from 11 PubChem assays through 1,350 experiments that involved approximately 500,000 interactions between chemicals and their target proteins. As an example of potential use, we applied DRAMOTE to develop robust models for predicting FDA approved drugs that have high probability to interact with the thyroid stimulating hormone receptor (TSHR) in humans. Our findings are further partially and indirectly supported by 3D docking results and literature information. The results based on approximately 500,000 interactions suggest that DRAMOTE has performed the best and that it can be used for developing robust virtual screening models. The datasets and implementation of all solutions are available as a MATLAB toolbox online at www.cbrc.kaust.edu.sa/dramote and can be found on Figshare.

  2. BioAssay templates for the semantic web

    Directory of Open Access Journals (Sweden)

    Alex M. Clark

    2016-05-01

    Full Text Available Annotation of bioassay protocols using semantic web vocabulary is a way to make experiment descriptions machine-readable. Protocols are communicated using concise scientific English, which precludes most kinds of analysis by software algorithms. Given the availability of a sufficiently expressive ontology, some or all of the pertinent information can be captured by asserting a series of facts, expressed as semantic web triples (subject, predicate, object. With appropriate annotation, assays can be searched, clustered, tagged and evaluated in a multitude of ways, analogous to other segments of drug discovery informatics. The BioAssay Ontology (BAO has been previously designed for this express purpose, and provides a layered hierarchy of meaningful terms which can be linked to. Currently the biggest challenge is the issue of content creation: scientists cannot be expected to use the BAO effectively without having access to software tools that make it straightforward to use the vocabulary in a canonical way. We have sought to remove this barrier by: (1 defining a BioAssay Template (BAT data model; (2 creating a software tool for experts to create or modify templates to suit their needs; and (3 designing a common assay template (CAT to leverage the most value from the BAO terms. The CAT was carefully assembled by biologists in order to find a balance between the maximum amount of information captured vs. low degrees of freedom in order to keep the user experience as simple as possible. The data format that we use for describing templates and corresponding annotations is the native format of the semantic web (RDF triples, and we demonstrate some of the ways that generated content can be meaningfully queried using the SPARQL language. We have made all of these materials available as open source (http://github.com/cdd/bioassay-template, in order to encourage community input and use within diverse projects, including but not limited to our own

  3. Mining Chemical Activity Status from High-Throughput Screening Assays

    KAUST Repository

    Soufan, Othman; Ba Alawi, Wail; Afeef, Moataz A.; Essack, Magbubah; Rodionov, Valentin; Kalnis, Panos; Bajic, Vladimir B.

    2015-01-01

    High-throughput screening (HTS) experiments provide a valuable resource that reports biological activity of numerous chemical compounds relative to their molecular targets. Building computational models that accurately predict such activity status (active vs. inactive) in specific assays is a challenging task given the large volume of data and frequently small proportion of active compounds relative to the inactive ones. We developed a method, DRAMOTE, to predict activity status of chemical compounds in HTP activity assays. For a class of HTP assays, our method achieves considerably better results than the current state-of-the-art-solutions. We achieved this by modification of a minority oversampling technique. To demonstrate that DRAMOTE is performing better than the other methods, we performed a comprehensive comparison analysis with several other methods and evaluated them on data from 11 PubChem assays through 1,350 experiments that involved approximately 500,000 interactions between chemicals and their target proteins. As an example of potential use, we applied DRAMOTE to develop robust models for predicting FDA approved drugs that have high probability to interact with the thyroid stimulating hormone receptor (TSHR) in humans. Our findings are further partially and indirectly supported by 3D docking results and literature information. The results based on approximately 500,000 interactions suggest that DRAMOTE has performed the best and that it can be used for developing robust virtual screening models. The datasets and implementation of all solutions are available as a MATLAB toolbox online at www.cbrc.kaust.edu.sa/dramote and can be found on Figshare.

  4. Automation of the anthrone assay for carbohydrate concentration determinations.

    Science.gov (United States)

    Turula, Vincent E; Gore, Thomas; Singh, Suddham; Arumugham, Rasappa G

    2010-03-01

    Reported is the adaptation of a manual polysaccharide assay applicable for glycoconjugate vaccines such as Prevenar to an automated liquid handling system (LHS) for improved performance. The anthrone assay is used for carbohydrate concentration determinations and was scaled to the microtiter plate format with appropriate mixing, dispensing, and measuring operations. Adaptation and development of the LHS platform was performed with both dextran polysaccharides of various sizes and pneumococcal serotype 6A polysaccharide (PnPs 6A). A standard plate configuration was programmed such that the LHS diluted both calibration standards and a test sample multiple times with six replicate preparations per dilution. This extent of replication minimized the effect of any single deviation or delivery error that might have occurred. Analysis of the dextran polymers ranging in size from 214 kDa to 3.755 MDa showed that regardless of polymer chain length the hydrolysis was complete, as evident by uniform concentration measurements. No plate positional absorbance bias was observed; of 12 plates analyzed to examine positional bias the largest deviation observed was 0.02% percent relative standard deviation (%RSD). The high purity dextran also afforded the opportunity to assess LHS accuracy; nine replicate analyses of dextran yielded a mean accuracy of 101% recovery. As for precision, a total of 22 unique analyses were performed on a single lot of PnPs 6A, and the resulting variability was 2.5% RSD. This work demonstrated the capability of a LHS to perform the anthrone assay consistently and a reduced assay cycle time for greater laboratory capacity.

  5. Nondestructive assay technology and automated ''real-time'' materials control

    International Nuclear Information System (INIS)

    Keepin, G.R.

    1977-01-01

    Significant advances in nondestructive assay techniques and instrumentation now enable rapid, accurate and direct in-plant measurement of nuclear material on a continuous or ''real-time'' basis as it progresses through a nuclear facility. A variety of passive and active assay instruments are required for the broad range of materials measurement problems encountered by safeguards inspectors and facility operators in various types of nuclear plants. Representative NDA techniques and instruments are presented and reviewed with special attention to their assay capabilities and areas of applicability in the nuclear fuel cycle. An advanced system of materials control - called ''DYMAC'', for Dynamic Materials Control - is presently under development by the U.S. Energy Research and Development Administration; the DYMAC program integrates new nondestructive assay instrumentation and modern data-processing methods, with the overall objective of demonstrating a workable, cost-effective system of stringent safeguards and materials control in various generic types of facilities found in the nuclear fuel cycle. Throughout the program, emphasis will be placed on devloping practical solutions to generic measurement problems so that resulting techniques and instrumentation will have widespread utility. Projected levels of safeguards assurance, together with other vital - and cost-sensitive - plant operational factors such as process and quality control, criticality safety and waste management are examined in an evaluation of the impact of future advanced materials control systems on overall plant operations, efficiency and productivity. The task of implementing effective and stringent safeguards includes the transfer of new safeguards technology to the nuclear industry. Clearly the training of inspectors (both IAEA and national), plant people, etc., in the effective use of new NDA equipment is of paramount importance; thus in the United States, the Energy Research and Development

  6. Evaluation of the Thermo Scientific™ SureTect™ Listeria species Assay.

    Science.gov (United States)

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-03-01

    The Thermo Scientific™ SureTect™ Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested MethodsSM program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University of Guelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the

  7. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    Science.gov (United States)

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay

  8. Contribution of murine innate serum inhibitors toward interference within influenza virus immune assays.

    Science.gov (United States)

    Cwach, Kevin T; Sandbulte, Heather R; Klonoski, Joshua M; Huber, Victor C

    2012-03-01

    Prior to detection of an antibody response toward influenza viruses using the hemagglutination inhibition assay (HAI), sera are routinely treated to inactivate innate inhibitors using both heat inactivation (56°C) and recombinant neuraminidase [receptor-destroying enzyme (RDE)]. We revisited the contributions of innate serum inhibitors toward interference with influenza viruses in immune assays, using murine sera, with emphasis on the interactions with influenza A viruses of the H3N2 subtype. We used individual serum treatments: 56°C alone, RDE alone, or RDE + 56°C, to treat sera prior to evaluation within HAI, microneutralization, and macrophage uptake assays. Our data demonstrate that inhibitors present within untreated murine sera interfere with the HAI assay in a manner that is different from that seen for the microneutralization assay. Specifically, the γ class inhibitor α(2) -Macroglobulin (A2-M) can inhibit H3N2 viruses within the HAI assay, but not in the microneutralization assay. Based on these findings, we used a macrophage uptake assay to demonstrate that these inhibitors can increase uptake by macrophages when the influenza viruses express an HA from a 1968 H3N2 virus isolate, but not a 1997 H3N2 isolate. The practice of treating sera to inactivate innate inhibitors of influenza viruses prior to evaluation within immune assays has allowed us to effectively detect influenza virus-specific antibodies for decades. However, this practice has yielded an under-appreciation for the contribution of innate serum inhibitors toward host immune responses against these viruses, including contributions toward neutralization and macrophage uptake. © 2011 Blackwell Publishing Ltd.

  9. Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paraskevi Vogiatzi

    2013-01-01

    Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.

  10. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    Science.gov (United States)

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  11. Development of a One-Step Multiplex PCR Assay for Differential Detection of Major Mycobacterium Species.

    Science.gov (United States)

    Chae, Hansong; Han, Seung Jung; Kim, Su-Young; Ki, Chang-Seok; Huh, Hee Jae; Yong, Dongeun; Koh, Won-Jung; Shin, Sung Jae

    2017-09-01

    The prevalence of tuberculosis continues to be high, and nontuberculous mycobacterial (NTM) infection has also emerged worldwide. Moreover, differential and accurate identification of mycobacteria to the species or subspecies level is an unmet clinical need. Here, we developed a one-step multiplex PCR assay using whole-genome analysis and bioinformatics to identify novel molecular targets. The aims of this assay were to (i) discriminate between the Mycobacterium tuberculosis complex (MTBC) and NTM using rv0577 or RD750, (ii) differentiate M. tuberculosis ( M. tuberculosis ) from MTBC using RD9, (iii) selectively identify the widespread M. tuberculosis Beijing genotype by targeting mtbk_20680 , and (iv) simultaneously detect five clinically important NTM ( M. avium , M. intracellulare , M. abscessus , M. massiliense , and M. kansasii ) by targeting IS 1311 , DT1, mass_3210 , and mkan_rs12360 An initial evaluation of the multiplex PCR assay using reference strains demonstrated 100% specificity for the targeted Mycobacterium species. Analytical sensitivity ranged from 1 to 10 pg for extracted DNA and was 10 3 and 10 4 CFU for pure cultures and nonhomogenized artificial sputum cultures, respectively, of the targeted species. The accuracy of the multiplex PCR assay was further evaluated using 55 reference strains and 94 mycobacterial clinical isolates. Spoligotyping, multilocus sequence analysis, and a commercial real-time PCR assay were employed as standard assays to evaluate the multiplex PCR assay with clinical M. tuberculosis and NTM isolates. The PCR assay displayed 100% identification agreement with the standard assays. Our multiplex PCR assay is a simple, convenient, and reliable technique for differential identification of MTBC, M. tuberculosis , M. tuberculosis Beijing genotype, and major NTM species. Copyright © 2017 American Society for Microbiology.

  12. A new semiquantitative radiometric opsonin assay

    International Nuclear Information System (INIS)

    Yamamura, M.; Valdimarsson, H.

    1978-01-01

    A new semiquantitative radiometric opsonin assay is described. It was found that the opsonin activity generated by incubating brewer's yeast, Saccharomyces cerevisiae, in medium containing less than 5% human serum was exclusively complement dependent. In contrast, C.albicans was effectively opsonized in the absence of complement. Antibodies and the early classical complement pathway did not contribute to the opsonization of S.cerevisiae and neither did C5-9. The brewer's yeast assay can therefore be used for measuring selectively the opsonizing capacity of the alternative pathway. Sera from approximately 7% of apparently healthy adult controls consistently failed to generate significant opsonin activity while 8 out of 26 patients with suspected immune deficiency of unknown cause were defective in this assay. All opsonin deficient sera so far tested had haemolytically normal alternative pathway and Factor B activity. (author)

  13. Evaluation of a molybdenum assay canister

    International Nuclear Information System (INIS)

    Yoshizumi, T.T.; Keener, S.J.

    1988-01-01

    The performance characteristics of a commercial molybdenum assay canister were evaluated. The geometrical variation of the technetium-99m (/sup 99m/Tc) activity reading was studied as a function of the elution volume for the standard vials. It was found that the /sup 99m/Tc canister activity reading was ∼ 5% lower than that of the standard method. This is due to attenuation by the canister wall. However, the effect of the geometric variation on the clinical dose preparation was found to be insignificant. The molybdenum-99 ( 99 Mo) contamination level was compared by two methods: (1) the commercial canister and (2) the standard assay kit. The 99 Mo contamination measurements with the canister indicated consistently lower readings than those with the standard 99 Mo assay kit. The authors conclude that the canister may be used in the clinical settings. However, the user must be aware of the problems and the limitations associated with this canister

  14. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This session provides an introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards. The purpose of the sessions is to enable participants to: (1) discuss the general principles and major applications of NDA; (2) describe situations in which NDA is particularly useful for nuclear safeguards purposes; (3) distinguish between various passive and active gamma-ray and neutron NDA methods; (4) describe several NDA instruments that measure gamma rays, and identify assay situations particularly suited to gamma-ray techniques; (5) describe several NDA instruments that measure neutrons, and identify assay situations particularly suited to neutron techniques; (6) discuss the role of calorimetry in the NDA of plutonium-bearing materials; and (7) compare the advantages and disadvantages of various NDA methods for different types of nuclear materials

  15. Development of an integrated assay facility

    International Nuclear Information System (INIS)

    Molesworth, T.V.; Bailey, M.; Findlay, D.J.S.; Parsons, T.V.; Sene, M.R.; Swinhoe, M.T.

    1990-01-01

    The I.R.I.S. concept proposed the use of passive examination and active interrogation techniques in an integrated assay facility. A linac would generate the interrogating gamma and neutron beams. Insufficiently detailed knowledge about active neutron and gamma interrogation of 500 litre drums of cement immobilised intermediate level waste led to a research programme which is now in its main experimental stage. Measurements of interrogation responses are being made using simulated waste drums containing actinide samples and calibration sources, in an experimental assay assembly. Results show that responses are generally consistent with theory, but that improvements are needed in some areas. A preliminary appraisal of the engineering and economic aspects of integrated assay shows that correct operational sequencing is required to achieve the short cycle time needed for high throughput. The main engineering features of a facility have been identified

  16. Comet assay on tetraploid yeast cells

    DEFF Research Database (Denmark)

    Rank, Jette; Syberg, Kristian; Jensen, Klara

    2009-01-01

    Tetraploid yeast cells (Saccharomyces cerevisiae) were used in the comet assay with the intention of developing a new, fast and easy assay for detecting environmental genotoxic agents without using higher organisms. Two DNA-damaging chemicals, H2O2 and acrylamide, together with wastewater from...... three municipal treatment plants were tested for their effect on the yeast-cell DNA. The main problem with using yeast in the comet assay is the necessity to degrade the cell wall. This was achieved by using Zymolase 100 T twice during the procedure, since Zymolase 20 T did not open the cell wall....... Analytical problems that arose due to the small amount of DNA in the yeast nuclei in haploid and diploid cells, which contain 13 Mbp and 26 Mbp DNA per cell, respectively, were solved by using tetraploid yeast cells (52 Mbp) instead. DNA damage was shown after exposure to H2O2 and acrylamide. The lowest dose...

  17. Monitoring environmental exposures with semen assays

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Semen studies in humans and animals have yielded extensive and compelling evidence that sperm can be used to assess reproductive potential and diagnose pathology. More recent studies on mutagens and carcinogens both at this and other laboratories suggest that a combination of mouse and human assays can be an efficient, effective approach to monitoring for reproductive hazards in the environment. We are investigating the potential of using variability in sperm morphology and DNA content to quantify and monitor the effects of environmental agents on the human testes. Here we review the status of human and mouse assays for environmental surveillance, discuss the genetic and fertility implications of chemically induced semen changes, and describe the high-speed flow methods being developed to automate sperm assays

  18. Establishment of a novel radioligand assay using eukaryotically expressed cytochrome P4502D6 for the measurement of liver kidney microsomal type 1 antibody in patients with autoimmune hepatitis and hepatitis C virus infection.

    Science.gov (United States)

    Ma, Y; Gregorio, G; Gäken, J; Muratori, L; Bianchi, F B; Mieli-Vergani, G; Vergani, D

    1997-06-01

    Liver kidney microsomal type 1 antibody (LKM1) is the diagnostic marker of autoimmune hepatitis (AIH) type 2 and is also found in patients with hepatitis C virus (HCV) infection. Cytochrome P4502D6 (CYP2D6) is the documented target antigen of LKM1 in AIH, but not in HCV infection. To compare the reactivity in the two conditions, we established a radioligand assay using eukaryotically expressed CYP2D6 as target. A 1.2-kb human CYP2D6 cDNA was isolated from a human liver cDNA library and subcloned into an in vitro transcription vector pSP64 Poly(A). Recombinant CYP2D6 was then produced by in vitro transcription/translation, metabolically labelled with 35S methionine and used in the immunoprecipitation assay. Antibodies that bound radiolabelled CYP2D6 were immunoprecipitated and their levels assessed as cpm. Sera from 50 LKM1-positive patients (26 with AIH; 24 with HCV infection), 128 LKM1-negative patients and 57 normal controls were tested. Reactivity to 35S labelled CYP2D6 was observed in all LKM1-positive sera from patients with AIH and HCV infection, but in none of the controls. The cpm in both conditions were significantly higher than in normal controls (pLKM1 (r 0.87, p<0.001 and r=0.64, p<0.001 for AIH and HCV infection, respectively). Reactivity to 35S labelled CYP2D6 was inhibited by addition of an excess of eukaryotically expressed CYP2D6. CYP2D6 is a major target antigen of both AIH and HCV infection. The novel radioligand assay is highly sensitive and specific.

  19. Have you stress tested your assay?

    Directory of Open Access Journals (Sweden)

    Zheng Cao

    2016-08-01

    Full Text Available Objectives: When a clinical assay is stressed with extraordinarily high volume of specimens over a short period of time, extra caution may be needed to avoid systematic errors and biases. Here we report our experience with a HgbA1c assay used for high volume wellness screening purpose, to illustrate the importance of stress testing during assay validation. Design and Methods: Over 15,000 whole blood specimens were tested for HgbA1c in a period of 2 months. HgbA1c was tested by an immunoturbidimetric method on a high through-put automation line. The HgbA1c population distribution in our study was compared to that from the NHANES database. Daily distributions of HgbA1c values ≥6%, means and medians were plotted. Correlation studies were performed between the high through-put immunoturbidimetric assay and a medium through-put HPLC method. Results: We observed a shift of HgbA1c distribution to the higher values compared to the NHANES. A bias of 15–20% was noted from further stress testing where large number of samples were batched and tested using the immunoturbidimetric assay. A 5–7% higher bias remained after implementing a cuvette washing program after each HgbA1c sample. We hypothesized this bias was caused by build-up of blood cell fragments in the cuvettes when continuous whole blood samples are run through the system. Our experience suggests stress testing needs to be incorporated early in the test validation process for high volume batched screening applications. This seemingly extra validation step may save significant troubleshooting and retesting efforts down the road. Keywords: Hemoglobin A1c, Immunoturbidimetric assay, HPLC, Quality assurance, Systematic bias, High volume, Automation

  20. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  1. Demonstration of immunogenic keratan sulphate in commercial chondroitin 6-sulphate from shark cartilage. Implications for ELISA assays

    DEFF Research Database (Denmark)

    Møller, H J; Møller-Pedersen, T; Damsgaard, T E

    1995-01-01

    The prototype monoclonal keratan sulphate (KS) antibody 5D4 that is widely used for detection of KS in tissues and biological fluids reacts strongly with commercial low grade shark cartilage chondroitin 6-sulphate. Characterization of the immunogenic material by chondroitinase ABC digestion, ELISA...... inhibition studies, immunoblotting and HPLC analyses confirmed the presence of substantial amounts of KS, probably as a large proteoglycan (> 120 kDa). Commercial and heterogenic glycosaminoglycan preparations therefore must be used with great caution in immunological analyses. On the other hand the shark...... cartilage chondroitin 6-sulphate is an easy accessible source of immunogenic KS that can be used as a reference standard and as coating antigen in KS-ELISAs. The concentration of immunogenic KS in synovial fluid measured with an ELISA based solely on reagents of shark cartilage chondroitin 6-sulphate...

  2. Demonstration of immunogenic keratan sulphate in commercial chondroitin 6-sulphate from shark cartilage. Implications for ELISA assays

    DEFF Research Database (Denmark)

    Møller, H J; Møller-Pedersen, T; Damsgaard, T E

    1995-01-01

    The prototype monoclonal keratan sulphate (KS) antibody 5D4 that is widely used for detection of KS in tissues and biological fluids reacts strongly with commercial low grade shark cartilage chondroitin 6-sulphate. Characterization of the immunogenic material by chondroitinase ABC digestion, ELISA...... cartilage chondroitin 6-sulphate is an easy accessible source of immunogenic KS that can be used as a reference standard and as coating antigen in KS-ELISAs. The concentration of immunogenic KS in synovial fluid measured with an ELISA based solely on reagents of shark cartilage chondroitin 6-sulphate...... correlated well (r = 0.90) with the concentrations obtained with a traditional KS-ELISA that uses purified aggrecan as standard and coating antigen, and KS in both serum and synovial fluid could be measured with sufficient linearity....

  3. Optimal use of tandem biotin and V5 tags in ChIP assays

    Directory of Open Access Journals (Sweden)

    Krpic Sanja

    2009-02-01

    Full Text Available Abstract Background Chromatin immunoprecipitation (ChIP assays coupled to genome arrays (Chip-on-chip or massive parallel sequencing (ChIP-seq lead to the genome wide identification of binding sites of chromatin associated proteins. However, the highly variable quality of antibodies and the availability of epitopes in crosslinked chromatin can compromise genomic ChIP outcomes. Epitope tags have often been used as more reliable alternatives. In addition, we have employed protein in vivo biotinylation tagging as a very high affinity alternative to antibodies. In this paper we describe the optimization of biotinylation tagging for ChIP and its coupling to a known epitope tag in providing a reliable and efficient alternative to antibodies. Results Using the biotin tagged erythroid transcription factor GATA-1 as example, we describe several optimization steps for the application of the high affinity biotin streptavidin system in ChIP. We find that the omission of SDS during sonication, the use of fish skin gelatin as blocking agent and choice of streptavidin beads can lead to significantly improved ChIP enrichments and lower background compared to antibodies. We also show that the V5 epitope tag performs equally well under the conditions worked out for streptavidin ChIP and that it may suffer less from the effects of formaldehyde crosslinking. Conclusion The combined use of the very high affinity biotin tag with the less sensitive to crosslinking V5 tag provides for a flexible ChIP platform with potential implications in ChIP sequencing outcomes.

  4. Optimal use of tandem biotin and V5 tags in ChIP assays

    Science.gov (United States)

    Kolodziej, Katarzyna E; Pourfarzad, Farzin; de Boer, Ernie; Krpic, Sanja; Grosveld, Frank; Strouboulis, John

    2009-01-01

    Background Chromatin immunoprecipitation (ChIP) assays coupled to genome arrays (Chip-on-chip) or massive parallel sequencing (ChIP-seq) lead to the genome wide identification of binding sites of chromatin associated proteins. However, the highly variable quality of antibodies and the availability of epitopes in crosslinked chromatin can compromise genomic ChIP outcomes. Epitope tags have often been used as more reliable alternatives. In addition, we have employed protein in vivo biotinylation tagging as a very high affinity alternative to antibodies. In this paper we describe the optimization of biotinylation tagging for ChIP and its coupling to a known epitope tag in providing a reliable and efficient alternative to antibodies. Results Using the biotin tagged erythroid transcription factor GATA-1 as example, we describe several optimization steps for the application of the high affinity biotin streptavidin system in ChIP. We find that the omission of SDS during sonication, the use of fish skin gelatin as blocking agent and choice of streptavidin beads can lead to significantly improved ChIP enrichments and lower background compared to antibodies. We also show that the V5 epitope tag performs equally well under the conditions worked out for streptavidin ChIP and that it may suffer less from the effects of formaldehyde crosslinking. Conclusion The combined use of the very high affinity biotin tag with the less sensitive to crosslinking V5 tag provides for a flexible ChIP platform with potential implications in ChIP sequencing outcomes. PMID:19196479

  5. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Hatcher, C.R.; Smith, H.

    1984-01-01

    A thorough introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards is presented. The general principles and major applications of NDA are discussed and situations in which NDA is particularly useful for nuclear safeguards purposes are described. Various passive and active γ-ray and neutron methods are examined and assay situations particularly suited to γ-ray techniques, or to neutron techniques are identified. The role of calorimetry in the NDA of plutonium-bearing materials is also discussed. The advantages and disadvantages of various NDA methods for different types of nuclear materials are mentioned

  6. A sensitive assay for Staphylococcus aureus nucleases

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, J K; Vakil, B V; Patil, M S; Pandey, V N; Pradhan, D S [Bhabha Atomic Reserach Centre, Bombay (India). Biochemistry Div.

    1989-10-01

    A sensitive assay for staphylococcal nuclease involving incubation of the enzyme sample with heat-denatured ({sup 3}H) thymidine labelled DNA from E.coli, precipitation with trichloroacetic acid and measurement of the radioactivity of acid-soluble nucleotides released has been developed. The assay is sensitive enough to be used for comparing the levels of nucleases elaborated by different strains of S. aureus as well as for determining the extent of contamination of S. aureus in food and water samples even at levels at which the conventional spectrophotometric and toluidine blue-DNA methods are totally inadequate. (author). 26 refs., 3 figs ., 3 tabs.

  7. Limited diagnostic capacities of two commercial assays for the detection of Leptospira immunoglobulin M antibodies in Laos

    NARCIS (Netherlands)

    Blacksell, Stuart D.; Smythe, Lee; Phetsouvanh, Rattanaphone; Dohnt, Michael; Hartskeerl, Rudy; SymondS, Meegan; Slack, Andrew; Vongsouvath, Manivanh; Davong, Viengmone; Lattana, Olay; Phongmany, Simmaly; Keolouangkot, Valy; White, Nicholas J.; Day, Nicholas P. J.; Newton, Paul N.

    2006-01-01

    The diagnostic utility of immunochromatographic (Leptotek) and enzyme-linked immunosorbent assay (ELISA; Panbio) tests for the detection of Leptospira immunoglobulin M antibodies was assessed in febrile adults admitted in Vientiane, Laos. Both tests demonstrated poor diagnostic accuracy using

  8. Development and demonstration program for dynamic nuclear materials control

    International Nuclear Information System (INIS)

    Augustson, R.H.; Baron, N.; Ford, R.F.; Ford, W.; Hagen, J.; Li, T.K.; Marshall, R.S.; Reams, V.S.; Severe, W.R.; Shirk, D.G.

    1978-01-01

    A significant portion of the Los Alamos Scientific Laboratory Safeguards Program is directed toward the development and demonstration of dynamic nuclear materials control. The building chosen for the demonstration system is the new Plutonium Processing Facility in Los Alamos, which houses such operations as metal-to-oxide conversion, fuel pellet fabrication, and scrap recovery. A DYnamic MAterials Control (DYMAC) system is currently being installed in the facility as an integral part of the processing operation. DYMAC is structured around interlocking unit-process accounting areas. It relies heavily on nondestructive assay measurements made in the process line to draw dynamic material balances in near real time. In conjunction with the nondestructive assay instrumentation, process operators use interactive terminals to transmit additional accounting and process information to a dedicated computer. The computer verifies and organizes the incoming data, immediately updates the inventory records, monitors material in transit using elapsed time, and alerts the Nuclear Materials Officer in the event that material balances exceed the predetermined action limits. DYMAC is part of the United States safeguards system under control of the facility operator. Because of its advanced features, the system will present a new set of inspection conditions to the IAEA, whose response is the subject of a study being sponsored by the US-IAEA Technical Assistance Program. The central issue is how the IAEA can use the increased capabilities of such a system and still maintain independent verification

  9. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  10. Potency assay design for adjuvanted recombinant proteins as malaria vaccines.

    Science.gov (United States)

    Giersing, Birgitte K; Dubovsky, Filip; Saul, Allan; Denamur, Francoise; Minor, Philip; Meade, Bruce

    2006-05-15

    Many licensed vaccines are composed of live, attenuated or inactivated whole-cell microorganisms, or they comprise purified components from whole-cell extracts or culture supernatants. For some diseases, pathology is fairly well understood, and there may be known correlates of protection that provide obvious parameters for assessment of vaccine potency. However, this is not always the case, and some effective vaccines are routinely used even though the mechanisms or correlates of protection are unknown. Some more modern vaccine approaches employ purified recombinant proteins, based on molecules that appear on the surface of the pathogen. This is one of the strategies that has been adopted in the quest to develop a malaria vaccine. Use of these parasite antigens as vaccine candidates is supported by substantial epidemiological data, and some have demonstrated the ability to elicit protective responses in animal models of malaria infection. However, there is as yet no immunological correlate of protection and no functional assays or animal models that have demonstrated the ability to predict efficacy in humans. There is little precedence for the most appropriate and practical method for assessing potency of vaccines based on these recombinant molecules for malaria vaccines. This is likely because the majority of malaria vaccine candidates have only recently entered clinical evaluation. The PATH Malaria Vaccine Initiative (MVI) convened a panel with expertise in potency assay design from industry, governmental institutions, and regulatory bodies to discuss and review the rationale, available methods, and best approaches for assessing the potency of recombinant proteins, specifically for their use as malarial vaccines. The aim of this meeting was to produce a discussion document on the practical potency assessment of recombinant protein malaria vaccines, focusing on early phase potency assay development.

  11. Didactic demonstrations of superfluidity and superconductivity phenomena

    International Nuclear Information System (INIS)

    Aniola-Jedrzejak, L.; Lewicki, A.; Pilipowicz, A.; Tarnawski, Z.; Bialek, H.

    1980-01-01

    In order to demonstrate to students phenomena of superfluidity and superconductivity a special helium cryostat has been constructed. The demonstrated effects, construction of the cryostat and the method of demonstration are described. (author)

  12. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    Science.gov (United States)

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  13. Comparison of Antioxidant Evaluation Assays for Investigating Antioxidative Activity of Gallic Acid and Its Alkyl Esters in Different Food Matrices.

    Science.gov (United States)

    Phonsatta, Natthaporn; Deetae, Pawinee; Luangpituksa, Pairoj; Grajeda-Iglesias, Claudia; Figueroa-Espinoza, Maria Cruz; Le Comte, Jérôme; Villeneuve, Pierre; Decker, Eric A; Visessanguan, Wonnop; Panya, Atikorn

    2017-08-30

    The addition of antioxidants is one of the strategies to inhibit lipid oxidation, a major cause of lipid deterioration in foods leading to rancidity development and nutritional losses. However, several studies have been reported that conventional antioxidant assays, e.g., TPC, ABTS, FRAP, and ORAC could not predict antioxidant performance in several foods. This study aimed to investigate the performance of two recently developed assays, e.g., the conjugated autoxidizable triene (CAT) and the apolar radical-initiated conjugated autoxidizable triene (ApoCAT) assays to predict the antioxidant effectiveness of gallic acid and its esters in selected food models in comparison with the conventional antioxidant assays. The results indicated that the polarities of the antioxidants have a strong impact on antioxidant activities. In addition, different oxidant locations demonstrated by the CAT and ApoCAT assays influenced the overall antioxidant performances of the antioxidants with different polarities. To validate the predictability of the assays, the antioxidative performance of gallic acid and its alkyl esters was investigated in oil-in-water (O/W) emulsions, bulk soybean oils, and roasted peanuts as the lipid food models. The results showed that only the ApoCAT assay could be able to predict the antioxidative performances in O/W emulsions regardless of the antioxidant polarities. This study demonstrated that the relevance of antioxidant assays to food models was strongly dependent on physical similarities between the tested assays and the food structure matrices.

  14. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  15. A homogeneous fluorometric assay platform based on novel synthetic proteins

    International Nuclear Information System (INIS)

    Vardar-Schara, Goenuel; Krab, Ivo M.; Yi, Guohua; Su, Wei Wen

    2007-01-01

    Novel synthetic recombinant sensor proteins have been created to detect analytes in solution, in a rapid single-step 'mix and read' noncompetitive homogeneous assay process, based on modulating the Foerster resonance energy transfer (FRET) property of the sensor proteins upon binding to their targets. The sensor proteins comprise a protein scaffold that incorporates a specific target-capturing element, sandwiched by genetic fusion between two molecules that form a FRET pair. The utility of the sensor proteins was demonstrated via three examples, for detecting an anti-biotin Fab antibody, a His-tagged recombinant protein, and an anti-FLAG peptide antibody, respectively, all done directly in solution. The diversity of sensor-target interactions that we have demonstrated in this study points to a potentially universal applicability of the biosensing concept. The possibilities for integrating a variety of target-capturing elements with a common sensor scaffold predict a broad range of practical applications

  16. Rapid extraction and assay of uranium from environmental surface samples

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.; Olsen, Khris B.; Addleman, Raymond Shane

    2017-10-01

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonate and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.

  17. Using a medium-throughput comet assay to evaluate the global DNA methylation status of single cells

    Science.gov (United States)

    Lewies, Angélique; Van Dyk, Etresia; Wentzel, Johannes F.; Pretorius, Pieter J.

    2014-01-01

    The comet assay is a simple and cost effective technique, commonly used to analyze and quantify DNA damage in individual cells. The versatility of the comet assay allows introduction of various modifications to the basic technique. The difference in the methylation sensitivity of the isoschizomeric restriction enzymes HpaII and MspI are used to demonstrate the ability of the comet assay to measure the global DNA methylation level of individual cells when using cell cultures. In the experiments described here, a medium-throughput comet assay and methylation sensitive comet assay are combined to produce a methylation sensitive medium-throughput comet assay to measure changes in the global DNA methylation pattern in individual cells under various growth conditions. PMID:25071840

  18. Development of a Rapid Real-Time PCR Assay for Quantitation of Pneumocystis carinii f. sp. Carinii

    DEFF Research Database (Denmark)

    Larsen, Hans Henrik; Kovacs, Joseph A; Stock, Frida

    2002-01-01

    ) PCR assay for detecting P. carinii f. sp. carinii, the subspecies of P. carinii commonly used in research models of PCP. The assay was based on the single-copy dihydrofolate reductase gene and was able to detect r = 0.99) over...... 6 log values for standards containing > or =5 copies/tube. Application of the assay to a series of 10-fold dilutions of P. carinii organisms isolated from rat lung demonstrated that it was reproducibly quantitative over 5 log values (r = 0.99). The assay was applied to a recently reported in vitro....... In conclusion, a rapid, sensitive, and reproducible quantitative PCR assay for P. carinii f. sp. carinii has been developed and is applicable to in vivo as well as in vitro systems. The assay should prove useful for conducting studies in which quantification of organism burden or growth assessment is critical...

  19. Sample preparation composite and replicate strategy for assay of solid oral drug products.

    Science.gov (United States)

    Harrington, Brent; Nickerson, Beverly; Guo, Michele Xuemei; Barber, Marc; Giamalva, David; Lee, Carlos; Scrivens, Garry

    2014-12-16

    In pharmaceutical analysis, the results of drug product assay testing are used to make decisions regarding the quality, efficacy, and stability of the drug product. In order to make sound risk-based decisions concerning drug product potency, an understanding of the uncertainty of the reportable assay value is required. Utilizing the most restrictive criteria in current regulatory documentation, a maximum variability attributed to method repeatability is defined for a drug product potency assay. A sampling strategy that reduces the repeatability component of the assay variability below this predefined maximum is demonstrated. The sampling strategy consists of determining the number of dosage units (k) to be prepared in a composite sample of which there may be a number of equivalent replicate (r) sample preparations. The variability, as measured by the standard error (SE), of a potency assay consists of several sources such as sample preparation and dosage unit variability. A sampling scheme that increases the number of sample preparations (r) and/or number of dosage units (k) per sample preparation will reduce the assay variability and thus decrease the uncertainty around decisions made concerning the potency of the drug product. A maximum allowable repeatability component of the standard error (SE) for the potency assay is derived using material in current regulatory documents. A table of solutions for the number of dosage units per sample preparation (r) and number of replicate sample preparations (k) is presented for any ratio of sample preparation and dosage unit variability.

  20. Evaluation of colorimetric assays for analyzing reductively methylated proteins: Biases and mechanistic insights.

    Science.gov (United States)

    Brady, Pamlea N; Macnaughtan, Megan A

    2015-12-15

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated proteins were analyzed using the absorbance at 280 nm to standardize the concentrations. Using model compounds, we demonstrate that the dimethylation of lysyl ε-amines does not affect the proteins' molar extinction coefficients at 280 nm. For the Bradford assay, the responses (absorbance per unit concentration) of the unmodified and reductively methylated proteins were similar, with a slight decrease in the response upon methylation. For the BCA assay, the responses of the reductively methylated proteins were consistently higher, overestimating the concentrations of the methylated proteins. The enhanced color formation in the BCA assay may be due to the lower acid dissociation constants of the lysyl ε-dimethylamines compared with the unmodified ε-amine, favoring Cu(II) binding in biuret-like complexes. The implications for the analysis of biologically methylated samples are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Validity of urinary monoamine assay sales under the "spot baseline urinary neurotransmitter testing marketing model".

    Science.gov (United States)

    Hinz, Marty; Stein, Alvin; Uncini, Thomas

    2011-01-01

    Spot baseline urinary monoamine assays have been used in medicine for over 50 years as a screening test for monoamine-secreting tumors, such as pheochromocytoma and carcinoid syndrome. In these disease states, when the result of a spot baseline monoamine assay is above the specific value set by the laboratory, it is an indication to obtain a 24-hour urine sample to make a definitive diagnosis. There are no defined applications where spot baseline urinary monoamine assays can be used to diagnose disease or other states directly. No peer-reviewed published original research exists which demonstrates that these assays are valid in the treatment of individual patients in the clinical setting. Since 2001, urinary monoamine assay sales have been promoted for numerous applications under the "spot baseline urinary neurotransmitter testing marketing model". There is no published peer-reviewed original research that defines the scientific foundation upon which the claims for these assays are made. On the contrary, several articles have been published that discredit various aspects of the model. To fill the void, this manuscript is a comprehensive review of the scientific foundation and claims put forth by laboratories selling urinary monoamine assays under the spot baseline urinary neurotransmitter testing marketing model.

  2. Enzyme activity assay of glycoprotein enzymes based on a boronate affinity molecularly imprinted 96-well microplate.

    Science.gov (United States)

    Bi, Xiaodong; Liu, Zhen

    2014-12-16

    Enzyme activity assay is an important method in clinical diagnostics. However, conventional enzyme activity assay suffers from apparent interference from the sample matrix. Herein, we present a new format of enzyme activity assay that can effectively eliminate the effects of the sample matrix. The key is a 96-well microplate modified with molecularly imprinted polymer (MIP) prepared according to a newly proposed method called boronate affinity-based oriented surface imprinting. Alkaline phosphatase (ALP), a glycoprotein enzyme that has been routinely used as an indicator for several diseases in clinical tests, was taken as a representative target enzyme. The prepared MIP exhibited strong affinity toward the template enzyme (with a dissociation constant of 10(-10) M) as well as superb tolerance for interference. Thus, the enzyme molecules in a complicated sample matrix could be specifically captured and cleaned up for enzyme activity assay, which eliminated the interference from the sample matrix. On the other hand, because the boronate affinity MIP could well retain the enzymatic activity of glycoprotein enzymes, the enzyme captured by the MIP was directly used for activity assay. Thus, additional assay time and possible enzyme or activity loss due to an enzyme release step required by other methods were avoided. Assay of ALP in human serum was successfully demonstrated, suggesting a promising prospect of the proposed method in real-world applications.

  3. Sample preparation composite and replicate strategy case studies for assay of solid oral drug products.

    Science.gov (United States)

    Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei

    2017-11-30

    Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    Science.gov (United States)

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A European multicenter study on the analytical performance of the VERIS HBV assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development of a replication-competent lentivirus assay for dendritic cell-targeting lentiviral vectors

    Directory of Open Access Journals (Sweden)

    Daniel C Farley

    Full Text Available It is a current regulatory requirement to demonstrate absence of detectable replication-competent lentivirus (RCL in lentiviral vector products prior to use in clinical trials. Immune Design previously described an HIV-1-based integration-deficient lentiviral vector for use in cancer immunotherapy (VP02. VP02 is enveloped with E1001, a modified Sindbis virus glycoprotein which targets dendritic cell-specific intercellular adhesion molecule-3-grabbing non-integrin (DC-SIGN expressed on dendritic cells in vivo. Vector enveloped with E1001 does not transduce T-cell lines used in standard HIV-1-based RCL assays, making current RCL testing formats unsuitable for testing VP02. We therefore developed a novel assay to test for RCL in clinical lots of VP02. This assay, which utilizes a murine leukemia positive control virus and a 293F cell line expressing the E1001 receptor DC-SIGN, meets a series of evaluation criteria defined in collaboration with US regulatory authorities and demonstrates the ability of the assay format to amplify and detect a hypothetical RCL derived from VP02 vector components. This assay was qualified and used to test six independent GMP production lots of VP02, in which no RCL was detected. We propose that the evaluation criteria used to rationally design this novel method should be considered when developing an RCL assay for any lentiviral vector.

  7. Two-Phase Microfluidic Systems for High Throughput Quantification of Agglutination Assays

    KAUST Repository

    Castro, David

    2018-04-01

    Lab-on-Chip, the miniaturization of the chemical and analytical lab, is an endeavor that seems to come out of science fiction yet is slowly becoming a reality. It is a multidisciplinary field that combines different areas of science and engineering. Within these areas, microfluidics is a specialized field that deals with the behavior, control and manipulation of small volumes of fluids. Agglutination assays are rapid, single-step, low-cost immunoassays that use microspheres to detect a wide variety molecules and pathogens by using a specific antigen-antibody interaction. Agglutination assays are particularly suitable for the miniaturization and automation that two-phase microfluidics can offer, a combination that can help tackle the ever pressing need of high-throughput screening for blood banks, epidemiology, food banks diagnosis of infectious diseases. In this thesis, we present a two-phase microfluidic system capable of incubating and quantifying agglutination assays. The microfluidic channel is a simple fabrication solution, using laboratory tubing. These assays are incubated by highly efficient passive mixing with a sample-to-answer time of 2.5 min, a 5-10 fold improvement over traditional agglutination assays. It has a user-friendly interface that that does not require droplet generators, in which a pipette is used to continuously insert assays on-demand, with no down-time in between experiments at 360 assays/h. System parameters are explored, using the streptavidin-biotin interaction as a model assay, with a minimum detection limit of 50 ng/mL using optical image analysis. We compare optical image analysis and light scattering as quantification methods, and demonstrate the first light scattering quantification of agglutination assays in a two-phase ow format. The application can be potentially applied to other biomarkers, which we demonstrate using C-reactive protein (CRP) assays. Using our system, we can take a commercially available CRP qualitative slide

  8. Enzymatic assay for methotrexate in erythrocytes

    DEFF Research Database (Denmark)

    Schrøder, H; Heinsvig, E M

    1985-01-01

    Methotrexate (MTX) accumulates in erythrocytes in MTX-treated patients. We present a modified enzymatic assay measuring MTX concentrations between 10 and 60 nmol/l in erythrocytes, adapted for a centrifugal analyser (Cobas Bio). About 40 patient's samples could be analysed within 1 h. The detection...

  9. Comet assay. Pt.1. Theory and practice

    International Nuclear Information System (INIS)

    Kruszewski, M.; Wojewodzka, M.; Iwanenko, T.

    1996-01-01

    Comet assay is a new method for measuring DNA breakage in a single cell. The main applications of the method are estimation of DNA single and double strand breaks, oxidative damage, pyrimidine dimers and (6-4)photoproducts, DNA-DNA and DNA-protein crosslinks. The method is used for studying DNA damage and its repair. (author).19 refs, 9 figs

  10. Benzodiazepine Synthesis and Rapid Toxicity Assay

    Science.gov (United States)

    Fletcher, James T.; Boriraj, Grit

    2010-01-01

    A second-year organic chemistry laboratory experiment to introduce students to general concepts of medicinal chemistry is described. Within a single three-hour time window, students experience the synthesis of a biologically active small molecule and the assaying of its biological toxicity. Benzodiazepine rings are commonly found in antidepressant…

  11. Nondestructive assay of HTGR fuel rods

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1974-01-01

    Performance characteristics of three different radioactive source NDA systems are compared for the assay of HTGR fuel rods and stacks of rods. These systems include the fast neutron Sb-Be assay system, the 252 Cf ''Shuffler,'' and the thermal neutron PAPAS assay system. Studies have been made to determinethe perturbation on the measurements from particle size, kernel Th/U ratio, thorium content, and hydrogen content. In addition to the total 235 U determination, the pellet-to-pellet or rod-to-rod uniformity of HTGR fuel rod stacks has been measured by counting the delayed gamma rays with a NaI through-hole in the PAPAS system. These measurements showed that rod substitutions can be detected easily in a fuel stack, and that detailed information is available on the loading variations in a uniform stack. Using a 1.0 mg 252 Cf source, assay rates of 2 to 4 rods/s are possible, thus facilitating measurement of 100 percent of a plant's throughput. (U.S.)

  12. The use of calorimetry for plutonium assay

    International Nuclear Information System (INIS)

    Mason, J.A.

    1982-12-01

    Calorimetry is a technique for measuring the thermal power of heat-producing substances. The technique may be applied to the measurement of plutonium-bearing materials which evolve heat as a result of alpha and beta decay. A calorimetric measurement of the thermal power of a plutonium sample, combined with a knowledge or measurement of the plutonium isotopic mass ratios of the sample provides a convenient and accurate, non-destructive measure of the total plutonium mass of the sample. The present report provides a description, and an assessment of the calorimetry technique applied to the assay of plutonium-bearing materials. Types and characteristics of plutonium calorimeters are considered, as well as calibration and operating procedures. The instrumentation used with plutonium calorimeters is described and the use of computer control for calorimeter automation is discussed. A critical review and assessment of plutonium calorimetry literature since 1970 is presented. Both fuel element and plutonium-bearing material calorimeters are considered. The different types of plutonium calorimeters are evaluated and their relative merits are discussed. A combined calorimeter and gamma-ray measurement assay system is considered. The design principles of plutonium assay calorimeters are considered. An automatic, computer-based calorimeter control system is proposed in conjunction with a general plutonium assay calorimeter design. (author)

  13. Endoproteolytic activity assay in malting barley

    Directory of Open Access Journals (Sweden)

    Blanca Gómez Guerrero

    2013-12-01

    Full Text Available Hydrolysis of barley proteins into peptides and amino acids is one of the most important processes during barley germination.The degradation of the endosperm stored proteins facilitates water and enzyme movements, enhances modification, liberates starch granules and increases soluble amino nitrogen. Protease activity is the result of the activities of a mixture of exo- and endo-proteases. The barley proteins are initially solubilized by endo-proteases and the further by exo-proteases. Four classes of endo-proteases have been described: serine-proteases, cysteine-proteases, aspartic-proteases and metallo-proteases. The objective of this work was to develop a rapid and colorimetric enzymatic assay to determine the endo-proteolytic activity of the four endo-protease classes using two different substrates: azo-gelatin and azo-casein. Optimum conditions for the assays such as: pH,reaction time and temperature and absorbance scale were determined. Azo-gelatin presented several difficulties in standardizing an “in solution” assay. On the other hand, azo-casein allowed standardization of the assay for the four enzyme classes to produce consistent results. The endo-proteoteolytic method developed was applied to determine the endo-protease activity in barley, malt and wort.

  14. 21 CFR 864.7425 - Carboxyhemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carboxyhemoglobin assay. 864.7425 Section 864.7425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7425 Carboxyhemoglobin...

  15. 21 CFR 864.7250 - Erythropoietin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Erythropoietin assay. 864.7250 Section 864.7250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7250 Erythropoietin...

  16. 21 CFR 864.7490 - Sulfhemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sulfhemoglobin assay. 864.7490 Section 864.7490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7490 Sulfhemoglobin...

  17. Radioligand assay for biotin in liver tissues

    International Nuclear Information System (INIS)

    Rettenmaier, R.

    1979-01-01

    A radioligand assay for biotin in liver tissue is described. 3 H-biotin is used as tracer and avidin as binder. The biotin-loaded avidin is separated from free biotin on dextran-coated charcoal, which leaves the avidin-biotin complex in the supernatant liquid. Thus, the avidin-biotin complex can easily be utilized for determination of the radioactivity. Calibration with known additions of biotin in the range 0.25-8.0 ng per assay sample yields a linear logit-log plot. The biotin is extracted from liver tissues by enzymatic proteolysis with papain. This treatment is optimized to liberate the bound forms of the vitamin. Microbiological parallel assays with Lactobacillus plantarum were in good agreement with the radioligand assay giving a regression coefficient of 0.974(n=44). The coefficient of variation was found to be 4.2% in the range 500-1200 ng of biotin per g of liver tissue (n=46). The method is simple and reliable and allows the simultaneous analysis of a considerable number of samples. (Auth.)

  18. Relationships between ytterbium precipitation assay, colorimetric ...

    African Journals Online (AJOL)

    digestion and metabolism of protein (Komolong et al., 2001). ... room temperature (25 °C) pending chemical analyses and in vitro ... assayed without sodium sulphite but with a heat-stable α-amylase due to the high ... of starch in the tree fruits.

  19. Nondestructive assay of boxed radioactive waste

    International Nuclear Information System (INIS)

    Gilles, W.P.; Roberts, R.J.; Jasen, W.G.

    1992-12-01

    This paper describes the problems related to the nondestructive assay (NDA) of boxed radioactive waste at the Hanford Site and how Westinghouse Hanford company (WHC) is solving the problems. The waste form and radionuclide content are described. The characteristics of the combined neutron and gamma-based measurement system are described

  20. High-throughput screening assay of hepatitis C virus helicase inhibitors using fluorescence-quenching phenomenon

    International Nuclear Information System (INIS)

    Tani, Hidenori; Akimitsu, Nobuyoshi; Fujita, Osamu; Matsuda, Yasuyoshi; Miyata, Ryo; Tsuneda, Satoshi; Igarashi, Masayuki; Sekiguchi, Yuji; Noda, Naohiro

    2009-01-01

    We have developed a novel high-throughput screening assay of hepatitis C virus (HCV) nonstructural protein 3 (NS3) helicase inhibitors using the fluorescence-quenching phenomenon via photoinduced electron transfer between fluorescent dyes and guanine bases. We prepared double-stranded DNA (dsDNA) with a 5'-fluorescent-dye (BODIPY FL)-labeled strand hybridized with a complementary strand, the 3'-end of which has guanine bases. When dsDNA is unwound by helicase, the dye emits fluorescence owing to its release from the guanine bases. Our results demonstrate that this assay is suitable for quantitative assay of HCV NS3 helicase activity and useful for high-throughput screening for inhibitors. Furthermore, we applied this assay to the screening for NS3 helicase inhibitors from cell extracts of microorganisms, and found several cell extracts containing potential inhibitors.

  1. Radioimmunoassay, acetylating radio-enzymatic assay, and microbioassay of gentamicin: a comparative study

    International Nuclear Information System (INIS)

    Stevens, P.; Young, L.S.; Hewitt, W.L.

    1975-01-01

    Gentamicin is an aminoglycoside antibiotic widely used to treat gram-negative bacillary infections. Because it has a low therapeutic index, monitoring of serum levels may help to insure adequacy of dosage and avoid toxicity. Microbiological assays are relatively slow and can be complicated by the presence of other antimicrobials. Radioimmunoassay (RIA) and acetylating radio-enzymatic assay (ARA) are new methods for gentamicin assay which offer the following advantages: rapidity (less than 3 hours); no interference by other antibiotics; RIA is extremely sensitive and ARA is versatile (being useful in the measurement of other aminoglycosides). Correlation coefficients determined by linear regression analysis of assays on 36 patient samples performed in duplicate on 2 different days demonstrated no significant difference in measurement of gentamicin by each of the methods. Factors such as numbers of specimens, cost, and time involved will affect the decision of the method to be applied in individual laboratories. (U.S.)

  2. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  3. A versatile electrowetting-based digital microfluidic platform for quantitative homogeneous and heterogeneous bio-assays

    Science.gov (United States)

    Vergauwe, Nicolas; Witters, Daan; Ceyssens, Frederik; Vermeir, Steven; Verbruggen, Bert; Puers, Robert; Lammertyn, Jeroen

    2011-05-01

    Electrowetting-on-dielectric (EWOD) lab-on-a-chip systems have already proven their potential within a broad range of bio-assays. Nevertheless, research on the analytical performance of those systems is limited, yet crucial for a further breakthrough in the diagnostic field. Therefore, this paper presents the intrinsic possibilities of an EWOD lab-on-a-chip as a versatile platform for homogeneous and heterogeneous bio-assays with high analytical performance. Both droplet dispensing and splitting cause variations in droplet size, thereby directly influencing the assay's performance. The extent to which they influence the performance is assessed by a theoretical sensitivity analysis, which allows the definition of a basic framework for the reduction of droplet size variability. Taking advantage of the optimized droplet manipulations, both homogeneous and heterogeneous bio-assays are implemented in the EWOD lab-on-a-chip to demonstrate the analytical capabilities and versatility of the device. A fully on-chip enzymatic assay is realized with high analytical performance. It demonstrates the promising capabilities of an EWOD lab-on-a-chip in food-related and medical applications, such as nutritional and blood analyses. Further, a magnetic bio-assay for IgE detection using superparamagnetic nanoparticles is presented whereby the nanoparticles are used as solid carriers during the bio-assay. Crucial elements are the precise manipulation of the superparamagnetic nanoparticles with respect to dispensing and separation. Although the principle of using nano-carriers is demonstrated for protein detection, it can be easily extended to a broader range of bio-related applications like DNA sensing. In heterogeneous bio-assays the chip surface is actively involved during the execution of the bio-assay. Through immobilization of specific biological compounds like DNA, proteins and cells a reactive chip surface is realized, which enhances the bio-assay performance. To demonstrate

  4. Production and assay of forskolin antibodies

    International Nuclear Information System (INIS)

    Ho, L.T.; Ho, R.J.

    1986-01-01

    Forskolin (Fo), a cardiovascular active diterpene of plant origin, has been widely used as a research tool in regulation of the catalytic activity of adenylate cyclase (AC). A linear relationship of Fo binding to plasma membrane with activation of AC has been reported. The present abstract describes the production and assay of Fo antibodies (AB). 7-0-Hemisuccinyl-7-deacetyl Fo, coupled to either human serum albumin or goat IgG, was injected into goats to elicit AB to Fo haptan. AB to Fo in antiserum or an isolated IgG fraction was tested by two assay methods, a radioimmunoassay using 3 H-Fo as a tracer and a colorimetric enzyme-linked immunosorbent assay (ELISA) using horse radish peroxidase-rabbit anti goat IgG as indicator. The titers for Fo antiserum were 4000-10,000. In the defined assay condition, approximately 20-25% of the added 3 H-Fo was found to bind to AB. The bound radioactivity was displaced by Fo-HSA or Fo-goat IgG or free unlabelled Fo ranging from 0.5-50 pmol/tube, or 5-500 nM. The IC 50 was approximately 8-10 pmol/tube or 80-100 nM. The binding of HRP-rabbit anti goat IgG in the ELISA was inhibited by proper Fo conjugate. The development of methods for production and assay for Fo AB may be useful in the study of mechanism of activation of AC by Fo and Fo-like compound

  5. Assays for mammalian tyrosinase: a comparative study

    International Nuclear Information System (INIS)

    Jara, J.R.; Solano, F.; Lozano, J.A.

    1988-01-01

    This work describes a comparative study of the tyrosinase activity determined using three methods which are the most extensively employed; two radiometric assays using L-tyrosine as substrate (tyrosine hydroxylase and melanin formation activities) and one spectrophotometric assay using L-dopa (dopa oxidase activity). The three methods were simultaneously employed to measure the activities of the soluble, melanosomal, and microsomal tyrosinase isozymes from Harding-Passey mouse melanoma through their purification processes. The aim of this study was to find any correlation among the tyrosinase activities measured by the three different assays and to determine whether that correlation varied with the isozyme and its degree of purification. The results show that mammalian tyrosinase has a greater turnover number for L-dopa than for L-tyrosine. Thus, enzyme activity, expressed as mumol of substrate transformed per min, is higher in assays using L-dopa as substrate than those using L-tyrosine. Moreover, the percentage of hydroxylated L-tyrosine that is converted into melanin is low and is affected by several factors, apparently decreasing the tyrosinase activity measured by the melanin formation assay. Bearing these considerations in mind, average interassay factors are proposed. Their values are 10 to transform melanin formation into tyrosine hydroxylase activity, 100 to transform tyrosine hydroxylase into dopa oxidase activity, and 1,000 to transform melanin formation into dopa oxidase activity. Variations in these values due to the presence in the tyrosinase preparations of either inhibitors or regulatory factors in melanogenesis independent of tyrosinase are also discussed

  6. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  7. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  8. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  9. Assay optimization for molecular detection of Zika virus

    NARCIS (Netherlands)

    Corman, Victor M.; Rasche, Andrea; Baronti, Cecile; Aldabbagh, Souhaib; Cadar, Daniel; Reusken, Chantal Bem; Pas, Suzan D.; Goorhuis, Abraham; Schinkel, Janke; Molenkamp, Richard; Kümmerer, Beate M.; Bleicker, Tobias; Brünink, Sebastian; Eschbach-Bludau, Monika; Eis-Hübinger, Anna M.; Koopmans, Marion P.; Schmidt-Chanasit, Jonas; Grobusch, Martin P.; de Lamballerie, Xavier; Drosten, Christian; Drexler, Jan Felix

    2016-01-01

    To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection. We compared seven published real-time RT-PCR assays and two new assays that we have developed. To determine the analytical sensitivity of each assay, we

  10. Short communication. Microculture syncytia assay for bovine leukemia virus

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.S.; Castro, A.E.; Pomeroy, K.A.; Johnson, D.W.; Muscoplat, C.C.

    1978-01-01

    A microculture syncytia assay for the detection of bovine leukemia virus (BLV) has been described and compared with the conventional macroculture assay. The microculture assay required fewer indicator cells, was as sensitive as the macroculture assay and provided a reproducible test for the detection and titration of BLV.

  11. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Directory of Open Access Journals (Sweden)

    Leo Heyndrickx

    Full Text Available BACKGROUND: Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s can provide measures of protective immunity. An international collaboration (NeutNet involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs and soluble CD4 (Phase I study. METHODS: In the present study (Phase II, polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (Virus Infectivity Assays, VIA, or Env (gp160-pseudotyped viruses (pseudoviruses, PSV produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP reporter gene expression. FINDINGS: Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014. Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. CONCLUSIONS: Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus

  12. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Science.gov (United States)

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus. Consistent with the Phase I study, we recommend

  13. A high-throughput assay of NK cell activity in whole blood and its clinical application

    International Nuclear Information System (INIS)

    Lee, Saet-byul; Cha, Junhoe; Kim, Im-kyung; Yoon, Joo Chun; Lee, Hyo Joon; Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan; Lee, Jae Myun; Lee, Kang Young; Kim, Jongsun

    2014-01-01

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as 51 Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer

  14. A laboratory-scale pretreatment and hydrolysis assay for determination of reactivity in cellulosic biomass feedstocks.

    Science.gov (United States)

    Wolfrum, Edward J; Ness, Ryan M; Nagle, Nicholas J; Peterson, Darren J; Scarlata, Christopher J

    2013-11-14

    The rapid determination of the release of structural sugars from biomass feedstocks is an important enabling technology for the development of cellulosic biofuels. An assay that is used to determine sugar release for large numbers of samples must be robust, rapid, and easy to perform, and must use modest amounts of the samples to be tested.In this work we present a laboratory-scale combined pretreatment and saccharification assay that can be used as a biomass feedstock screening tool. The assay uses a commercially available automated solvent extraction system for pretreatment followed by a small-scale enzymatic hydrolysis step. The assay allows multiple samples to be screened simultaneously, and uses only ~3 g of biomass per sample. If the composition of the biomass sample is known, the results of the assay can be expressed as reactivity (fraction of structural carbohydrate present in the biomass sample released as monomeric sugars). We first present pretreatment and enzymatic hydrolysis experiments on a set of representative biomass feedstock samples (corn stover, poplar, sorghum, switchgrass) in order to put the assay in context, and then show the results of the assay applied to approximately 150 different feedstock samples covering 5 different materials. From the compositional analysis data we identify a positive correlation between lignin and structural carbohydrates, and from the reactivity data we identify a negative correlation between both carbohydrate and lignin content and total reactivity. The negative correlation between lignin content and total reactivity suggests that lignin may interfere with sugar release, or that more mature samples (with higher structural sugars) may have more recalcitrant lignin. The assay presented in this work provides a robust and straightforward method to measure the sugar release after pretreatment and saccharification that can be used as a biomass feedstock screening tool. We demonstrated the utility of the assay by

  15. Multi-centre evaluation of recent troponin assays for the diagnosis of NSTEMI

    Directory of Open Access Journals (Sweden)

    Camille Chenevier-Gobeaux

    2018-07-01

    Full Text Available Objectives: We aimed to compare the use of nine different cardiac troponin (cTn assays (2 cTnT and 7 cTnI for the diagnosis of NSTEMI in a single multi-centre population. Design and methods: One hundred and fifty-eight patients were included (mean age 60 years, SD 17 years, including 23 patients (14% with NSTEMI. Results: The analytical comparison highlighted a large heterogeneity of cTn assays, as reflected by percentages of patients with detectable cTn, correlation coefficients, Passing-Bablok comparisons and concordance coefficients. Correlations within cTnI assays were good and correlation within cTnT assays was excellent. Diagnostic performances demonstrated that each cTn assay has specific threshold values. Furthermore, some assays (HS-cTnI and T, cTnI-Pathfast and cTnI-Centaur indicated high sensitivity and negative predictive value using the limit of detection (LoD diagnostic strategy. For the latter assays, a significant increase in specificity was found when using the 99th percentile or the H0-H3 strategies, in comparison to the LoD strategy. When applying the European Society of Cardiology H0-H3 algorithm, comparable diagnostic performances were obtained. Conclusion: All 9 cTn assays indicated overall good diagnostic performances for the diagnosis of NSTEMI in emergency departments when the recommended algorithm based on the variation of cTn value between two measurements at admission and 3 h later was used. Keywords: Cardiac troponin, High-sensitivity assay, Chest pain, Emergency department, NSTEMI, Analytical evaluation

  16. A high-throughput assay of NK cell activity in whole blood and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Saet-byul [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Cha, Junhoe [ATGen Co. Ltd., Sungnam (Korea, Republic of); Kim, Im-kyung [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoon, Joo Chun [Department of Microbiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Lee, Hyo Joon [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan [ATGen Co. Ltd., Sungnam (Korea, Republic of); Lee, Jae Myun [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Kang Young, E-mail: kylee117@yuhs.ac [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jongsun, E-mail: jkim63@yuhs.ac [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-14

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as {sup 51}Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer.

  17. Validation of the Filovirus Plaque Assay for Use in Preclinical Studies

    Directory of Open Access Journals (Sweden)

    Amy C. Shurtleff

    2016-04-01

    Full Text Available A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4 studies. After standardization studies were completed, Good Laboratory Practices (GLP-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV variant and Ebola Virus Kikwit (EBOV variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID. The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies.

  18. Performance of two Aspergillus IgG EIA assays compared with the precipitin test in chronic and allergic aspergillosis.

    Science.gov (United States)

    Baxter, C G; Denning, D W; Jones, A M; Todd, A; Moore, C B; Richardson, M D

    2013-04-01

    Detection of Aspergillus IgG antibodies is important in the diagnosis of chronic pulmonary aspergillosis and allergic bronchopulmonary aspergillosis. Immunoprecipitation techniques to detect these antibodies appear to lack sensitivity and accurate quantitation compared with enzyme immunoassays (EIA). This study assessed the performance of two commercial EIAs compared with counterimmunoelectrophoresis (CIE). This was a prospective cohort study of 175 adult patients with chronic or allergic pulmonary aspergillosis. Aspergillus IgG antibodies were detected using CIE, Phadia ImmunoCap Aspergillus IgG and Bio-Rad Platelia Aspergillus IgG. Inter-assay reproducibility was determined for each method and 25 patients had two serum samples analysed within a 6-month interval. When compared with CIE, both ImmunoCap and Platelia Aspergillus IgG had good sensitivity (97 and 93%, respectively) for detection of Aspergillus IgG antibodies. The level of agreement between the two EIAs for positive results was good, but the concentration of antibodies was not correlated between the tests or with CIE titre. ImmunoCap IgG inter-assay coefficient of variation was 5%, whereas Platelia IgG was 33%. Median ImmunoCap IgG values for CPA and allergic aspergillosis were 95 and 32 mg/L, respectively, whereas Platelia IgG values were >80 and 6 AU/mL. The direction of CIE titre change over 6 months was mirrored by ImmunoCap IgG levels in 92% of patients, and by Platelia IgG in 72% of patients. Both ImmunoCap and Platelia Aspergillus IgG EIAs are sensitive measures of Aspergillus IgG antibodies compared with CIE. However, ImmunoCap appears to have better reproducibility and may be more suitable for monitoring patient disease. © 2012 The Authors Clinical Microbiology and Infection © 2012 European Society of Clinical Microbiology and Infectious Diseases.

  19. A novel data mining method to identify assay-specific signatures in functional genomic studies

    Directory of Open Access Journals (Sweden)

    Guidarelli Jack W

    2006-08-01

    Full Text Available Abstract Background: The highly dimensional data produced by functional genomic (FG studies makes it difficult to visualize relationships between gene products and experimental conditions (i.e., assays. Although dimensionality reduction methods such as principal component analysis (PCA have been very useful, their application to identify assay-specific signatures has been limited by the lack of appropriate methodologies. This article proposes a new and powerful PCA-based method for the identification of assay-specific gene signatures in FG studies. Results: The proposed method (PM is unique for several reasons. First, it is the only one, to our knowledge, that uses gene contribution, a product of the loading and expression level, to obtain assay signatures. The PM develops and exploits two types of assay-specific contribution plots, which are new to the application of PCA in the FG area. The first type plots the assay-specific gene contribution against the given order of the genes and reveals variations in distribution between assay-specific gene signatures as well as outliers within assay groups indicating the degree of importance of the most dominant genes. The second type plots the contribution of each gene in ascending or descending order against a constantly increasing index. This type of plots reveals assay-specific gene signatures defined by the inflection points in the curve. In addition, sharp regions within the signature define the genes that contribute the most to the signature. We proposed and used the curvature as an appropriate metric to characterize these sharp regions, thus identifying the subset of genes contributing the most to the signature. Finally, the PM uses the full dataset to determine the final gene signature, thus eliminating the chance of gene exclusion by poor screening in earlier steps. The strengths of the PM are demonstrated using a simulation study, and two studies of real DNA microarray data – a study of

  20. Melt analysis of mismatch amplification mutation assays (Melt-MAMA: a functional study of a cost-effective SNP genotyping assay in bacterial models.

    Directory of Open Access Journals (Sweden)

    Dawn N Birdsell

    Full Text Available Single nucleotide polymorphisms (SNPs are abundant in genomes of all species and biologically informative markers extensively used across broad scientific disciplines. Newly identified SNP markers are publicly available at an ever-increasing rate due to advancements in sequencing technologies. Efficient, cost-effective SNP genotyping methods to screen sample populations are in great demand in well-equipped laboratories, but also in developing world situations. Dual Probe TaqMan assays are robust but can be cost-prohibitive and require specialized equipment. The Mismatch Amplification Mutation Assay, coupled with melt analysis (Melt-MAMA, is flexible, efficient and cost-effective. However, Melt-MAMA traditionally suffers from high rates of assay design failures and knowledge gaps on assay robustness and sensitivity. In this study, we identified strategies that improved the success of Melt-MAMA. We examined the performance of 185 Melt-MAMAs across eight different pathogens using various optimization parameters. We evaluated the effects of genome size and %GC content on assay development. When used collectively, specific strategies markedly improved the rate of successful assays at the first design attempt from ~50% to ~80%. We observed that Melt-MAMA accurately genotypes across a broad DNA range (~100 ng to ~0.1 pg. Genomic size and %GC content influence the rate of successful assay design in an independent manner. Finally, we demonstrated the versatility of these assays by the creation of a duplex Melt-MAMA real-time PCR (two SNPs and conversion to a size-based genotyping system, which uses agarose gel electrophoresis. Melt-MAMA is comparable to Dual Probe TaqMan assays in terms of design success rate and accuracy. Although sensitivity is less robust than Dual Probe TaqMan assays, Melt-MAMA is superior in terms of cost-effectiveness, speed of development and versatility. We detail the parameters most important for the successful application of