WorldWideScience

Sample records for immunofluorescence assays performed

  1. Performance of an ELISA and Indirect Immunofluorescence Assay in Serological Diagnosis of Zoonotic Cutaneous Leishmaniasis in Iran

    Directory of Open Access Journals (Sweden)

    Bahador Sarkari

    2014-01-01

    Full Text Available Serological assays have been extensively evaluated for diagnosis of visceral leishmaniasis (VL and considered as a routine method for diagnosis of VL while these methods are not properly evaluated for diagnosis of cutaneous leishmaniasis (CL. This study aimed to assess the performance of indirect immunofluorescent-antibody test (IFA and enzyme-linked immunosorbent assay (ELISA for serodiagnosis of cutaneous leishmaniasis in Iran. Sixty-one sera samples from parasitologically confirmed CL patients and 50 sera from healthy controls along with 50 sera from non-CL patients were collected. Antigen was prepared from promastigotes and amastigotes of Leishmania major. IFA was used to detect anti-Leishmania IgG while ELISA was used to detect anti-Leishmania IgM, total IgG, or IgG subclasses (IgG1 and 4. ELISA, for detection of total IgG and IgM, showed sensitivity of 83.6% and 84.7% and specificity of 62.7% and 54.6%, respectively. Sensitivity and specificity of ELISA for detecting IgG1 and IgG4 were 64%, 75% and 85%, 49%, respectively. Sensitivity and specificity of IFA were 91.6% and 81%. Conclusion. Findings of this study demonstrated that serological test, especially IFA, can be used for proper diagnosis of CL.

  2. Immunofluorescence

    International Nuclear Information System (INIS)

    Bongertz, V.; Castro, B.G.

    1990-01-01

    The advantages of the immunofluorescence assay (IFA) that allowing the specific 'in situ' localization of the antigen-antibody interaction, of paramount importance when complex antigenic preparations, such as for instance tissue sections, are studied. (L.M.J.) [pt

  3. Immunofluorescence Plaque Assay for African Swine Fever Virus

    Science.gov (United States)

    Tessler, J.; Hess, W. R.; Pan, I. C.; Trautman, R.

    1974-01-01

    Suitably diluted cell culture adapted African swine fever virus preparations were inoculated on VERO cell monolayers and grown on coverslips. Gum tragacanth was used as an overlay. After three days incubation at 37°C the infected cultures were fixed with acetone and stained with fluorescent antibody conjugate. Fluorescing plaques consisted of 20-30 infected cells. Three statistical criteria for a quantitatively reliable assay were met: the Poisson distribution for plaque counts, linearity of the relationship between the concentration of virus and the plaque count and reproducibility of replicate titrations. The method is suitable for counts up to at least 70 plaques per 5 cm2 coverslip and computed titers are reproducible within 0.16 log units with a total of 300 plaques enumerated. PMID:4279763

  4. Evaluation of immunofluorescence microscopy and enzyme-linked immunosorbent assay in detection of Cryptosporidium and Giardia infections in asymptomatic dogs

    DEFF Research Database (Denmark)

    Rimhanen-Finne, R.; Enemark, Heidi L.; Kolehmainen, J.

    2007-01-01

    The performance of immunofluorescence microscopy (IF) and enzyme-linked immunosorbent assay (ELISA) in canine feces was evaluated. IF and Cryptosporidium ELISA detected 10(5) oocysts/g, while the detection limit for Giardia ELISA was 10(4) cysts/g. The Cryptosporidium ELISA showed 94% specificity...... zoonotic character of Cryptosporidium and Giardia infections in 150 asymptomatic Finnish dogs from the Helsinki area were studied. The overall proportion of dogs positive for Cryptosporidium was 5% (7/150) and that for Giardia 5% (8/150). In dogs...

  5. Use of a Granulocyte Immunofluorescence Assay Designed for Humans for Detection of Antineutrophil Cytoplasmic Antibodies in Dogs with Chronic Enteropathies.

    Science.gov (United States)

    Florey, J; Viall, A; Streu, S; DiMuro, V; Riddle, A; Kirk, J; Perazzotti, L; Affeldt, K; Wagner, R; Vaden, S; Harris, T; Allenspach, K

    2017-07-01

    Perinuclear antineutrophil cytoplasmic antibodies (pANCA) previously have been shown to be serum markers in dogs with chronic enteropathies, with dogs that have food-responsive disease (FRD) having higher frequencies of seropositivity than dogs with steroid-responsive disease (SRD). The indirect immunofluorescence (IIF) assay used in previous publications is time-consuming to perform, with low interobserver agreement. We hypothesized that a commercially available granulocyte IIF assay designed for humans could be used to detect perinuclear antineutrophil cytoplasmic antibodies in dogs. Forty-four dogs with FRD, 20 dogs with SRD, 20 control dogs, and 38 soft-coated wheaten terrier (SCWT) or SCWT-cross dogs. A granulocyte assay designed for humans was used to detect pANCA, cANCA, and antinuclear antibodies (ANA), as well as antibodies against proteinase-3 protein (PR-3) and myeloperoxidase protein (MPO) in archived serum samples. Sensitivity of the granulocyte assay to predict FRD in dogs was 0.61 (95% confidence interval (CI), 0.45, 0.75), and specificity was 1.00 (95% CI, 0.91, 1.00). A significant association was identified between positive pANCA or cANCA result and diagnosis of FRD (P < 0.0001). Agreement between the two assays to detect ANCA in the same serum samples from SCWT with protein-losing enteropathy/protein-losing nephropathy (PLE/PLN) was substantial (kappa, 0.77; 95% CI, 0.53, 1.00). Eight ANCA-positive cases were positive for MPO or PR-3 antibodies. The granulocyte immunofluorescence assay used in our pilot study was easy and quick to perform. Agreement with the previously published method was good. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Neuromyelitis optica immunoglobulin G in Chinese patients detected by immunofluorescence assay on a monkey brain substrate.

    Science.gov (United States)

    Long, Youming; Hu, Xueqiang; Peng, Fuhua; Lu, Zhengqi; Wang, Yuge; Yang, Yu; Qiu, Wei

    2012-01-01

    Serum neuromyelitis optica immunoglobulin G (NMO-IgG) is used as a biomarker to differentiate between neuromyelitis optica (NMO) and multiple sclerosis (MS). However, the original assay is expensive and complex and shows low sensitivity. Here, we investigated the potential of NMO-IgG detection using an indirect immunofluorescence (IIF) assay on monkey brains. NMO-IgG seroprevalence was determined in 168 samples by an IIF assay on a monkey brain substrate. The data were compared with those from a standard mouse brain IIF assay using McNemar and kappa tests. Thirty-one of 50 (62%) NMO patients, 7 of 18 (38.9%) longitudinally extensive transverse myelitis patients, 6 of 57 (10.5%) MS patients, and 5 of 10 (50%) optic neuritis patients were seropositive for NMO-IgG. None of the acute partial transverse myelitis patients (n = 3) or healthy controls (n = 20) was positive. Thus, the sensitivity of the test was 62% for the patients with clinically definite NMO. The specificity was 89.5%, considering the 57 MS patients as the control group. The modified IIF assay on monkey brains and the standard IIF assay based on mouse brains were not significantly different (McNemar test; p = 1.000). The two assays were concordant in 39 seropositive samples and 100 seronegative samples (kappa test; kappa = 0.592, p monkey brain assay was no better than the standard mouse brain IIF assay, we affirmed that NMO-IgG is a sensitive and specific biomarker to differentiate between NMO and MS. Copyright © 2011 S. Karger AG, Basel.

  7. Automated two-site immunofluorescent assay for the measurement of serum chromogranin A.

    Science.gov (United States)

    Popovici, Théodora; Moreira, Baptiste; Schlageter, Marie-Hélène; Bories, Phuong-Nhi

    2014-01-01

    Chromogranin A (CgA) is the best-characterized biological marker common to neuroendocrine tumours and is therefore recommended for their diagnosis. The measurement of serum CgA is of great importance for reaching an early diagnosis and thus reducing the delay before treatment is instigated. The Kryptor CgA assay is the first fully automated assay available. The aim of this study was to evaluate its analytical performance. The imprecision and linearity of the Kryptor CgA assay were evaluated. This assay was compared with the Cis Bio CgA RIA assay in 78 serum samples. Its clinical utility was assessed in serum from 229 patients. The study performed on imprecision of Kryptor measurements showed intra- and inter-run CVs ≤ 5%. The study of linearity showed a satisfactory recovery rate for CgA concentrations up to 1200 μg/L. The Kryptor and RIA assays agreed well on the basis of the cut-off values provided by the two manufacturers. The Bland and Altman plot of the values obtained (range: 20-5560 μg/L) provided a mean difference of -10.1 μg/L (SD: 116). The clinical sensitivities of Kryptor CgA for diagnosis of pheochromocytoma and paraganglioma (n 20) and gastroenteropancreatic NETs (n 17) were respectively 100 and 94%. The Kryptor assay for CgA shows reliable analytical and clinical characteristics and allows a fast delivery of results. © 2013.

  8. Application of a sepharose bead immunofluorescence assay and a solid-phase radioimmunoassay to the bovine leukemia virus system

    International Nuclear Information System (INIS)

    Fiebach, H.; Uckert, W.; Micheel, B.

    1982-01-01

    Several fluorescence assays with bovine leukemia virus (BLV) conjugated to activated Sepharose 4B were used for the detection of BLV and anti-BLV antibodies. These tests were compared with a solid-phase radioimmunoassay and found to be in the same sensitivity range. Sepharose bead immunofluorescence assay and solid-phase radioimmunoassay can be applied to the diagnosis of BLV infection in cattle. (author)

  9. Application of a sepharose bead immunofluorescence assay and a solid-phase radioimmunoassay to the bovine leukemia virus system

    Energy Technology Data Exchange (ETDEWEB)

    Fiebach, H.; Uckert, W.; Micheel, B. (Akademie der Wissenschaften der DDR, Berlin. Zentralinstitut fuer Krebsforschung)

    Several fluorescence assays with bovine leukemia virus (BLV) conjugated to activated Sepharose 4B were used for the detection of BLV and anti-BLV antibodies. These tests were compared with a solid-phase radioimmunoassay and found to be in the same sensitivity range. Sepharose bead immunofluorescence assay and solid-phase radioimmunoassay can be applied to the diagnosis of BLV infection in cattle.

  10. Evaluation of a Direct Immunofluorescent Assay and/or Conjunctival Cytology for Detection of Canine Distemper Virus Antigen.

    Science.gov (United States)

    Athanasiou, Labrini V; Kantere, Maria C; Kyriakis, Constantinos S; Pardali, Dimitra; Adamama Moraitou, Katerina; Polizopoulou, Zoe S

    2018-04-01

    Canine distemper is a common and potentially lethal multisystemic disease caused by the Canine distemper virus (CDV). We evaluated the diagnostic performance of direct immunofluorescent assay (FA) and cytology to detect CDV antigen in conjunctival cells compared with an established polymerase chain reaction (PCR) detection assay used as a gold standard for CDV diagnosis. Samples were collected from 57 young dogs presenting with central nervous system signs compatible with distemper disease. Exfoliative epithelial cells were collected from the right and left conjunctiva of each animal using nylon-bristled cytobrushes for cytology and cotton swabs for FA and PCR. For the direct FA, samples were stained with anti-CDV polyclonal antiserum conjugated to fluorescein isothiocyanate and imaged using a fluorescent microscope. Out of 57 dogs tested, 19 were PCR positive (15 positive in direct FA and 4 positive in cytology, including one that was negative by PCR), whereas 37 dogs were negative in all methods. A good agreement was observed between the FA and PCR, with a κ-value of 0.833 (95% CI: 0.678-0.989). Meanwhile, there was poor agreement between cytology and PCR (κ-value of 0.164; 95% CI: -0.045 to 0.373) and a fair agreement between FA and cytology (κ-value of 0.231; 95% CI: -0.026 to 0.487). Our results indicated a poor performance of cytology for the detection of CDV antigen. In contrast, FA is a 100% specific and an adequately sensitive assay (sensitivity: 78.95%, negative likelihood ratio: 0.21, 95% CI: 0.09-0.50) for antemortem diagnosis of canine distemper.

  11. Direct immunofluorescence assay compared to cell culture for the diagnosis of mucocutaneous herpes simplex virus infections in children.

    Science.gov (United States)

    Caviness, A Chantal; Oelze, Lindsay L; Saz, Ulas E; Greer, Jewel M; Demmler-Harrison, Gail J

    2010-09-01

    Direct immunofluorescence assay (DFA) is commonly used for the rapid identification of herpes simplex virus (HSV) infection in mucocutaneous lesions, yet little is known about its diagnostic accuracy. To determine the diagnostic yield and accuracy of HSV DFA for the diagnosis of mucocutaneous HSV infection in pediatric patients. Retrospective cross-sectional study of all patients who underwent HSV DFA testing by the Texas Children's Hospital Diagnostic Virology between January 1, 1995 and December 31, 2005. HSV DFA sensitivity, specificity, positive likelihood ratio (LRs), and negative LRs were estimated using viral culture as the reference standard. 659 specimens were submitted for HSV DFA with concurrent viral cultures. Viral cultures were positive for HSV type 1 in 158 (24%) and HSV type 2 in 2 (0.3%). There were 433 different patients with a median age of 8.6 years. Types of lesions were as follows: 50% ulcerative, 26% vesicular, 8% erythema or purpura, 5% pustular, and 11% missing. Of the 659 specimens submitted for HSV DFA, 160 (24%) were inconclusive due to inadequate cells. Of the 499 adequate specimens, overall HSV DFA test accuracy was: sensitivity 61%, specificity 99%, LR positive 40, and LR negative 0.39. A quarter of specimens submitted for HSV DFA testing are not adequate for DFA testing. When HSV DFA can be performed, it is specific, but not sensitive, for the identification of mucocutaneous HSV infection in children. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  12. Performance analysis of automated evaluation of Crithidia luciliae-based indirect immunofluorescence tests in a routine setting - strengths and weaknesses.

    Science.gov (United States)

    Hormann, Wymke; Hahn, Melanie; Gerlach, Stefan; Hochstrate, Nicola; Affeldt, Kai; Giesen, Joyce; Fechner, Kai; Damoiseaux, Jan G M C

    2017-11-27

    Antibodies directed against dsDNA are a highly specific diagnostic marker for the presence of systemic lupus erythematosus and of particular importance in its diagnosis. To assess anti-dsDNA antibodies, the Crithidia luciliae-based indirect immunofluorescence test (CLIFT) is one of the assays considered to be the best choice. To overcome the drawback of subjective result interpretation that inheres indirect immunofluorescence assays in general, automated systems have been introduced into the market during the last years. Among these systems is the EUROPattern Suite, an advanced automated fluorescence microscope equipped with different software packages, capable of automated pattern interpretation and result suggestion for ANA, ANCA and CLIFT analysis. We analyzed the performance of the EUROPattern Suite with its automated fluorescence interpretation for CLIFT in a routine setting, reflecting the everyday life of a diagnostic laboratory. Three hundred and twelve consecutive samples were collected, sent to the Central Diagnostic Laboratory of the Maastricht University Medical Centre with a request for anti-dsDNA analysis over a period of 7 months. Agreement between EUROPattern assay analysis and the visual read was 93.3%. Sensitivity and specificity were 94.1% and 93.2%, respectively. The EUROPattern Suite performed reliably and greatly supported result interpretation. Automated image acquisition is readily performed and automated image classification gives a reliable recommendation for assay evaluation to the operator. The EUROPattern Suite optimizes workflow and contributes to standardization between different operators or laboratories.

  13. Determination of cutoff of ELISA and immunofluorescence assay for scrub typhus

    Directory of Open Access Journals (Sweden)

    Nitin Gupta

    2016-01-01

    Full Text Available Background: The most common method employed for diagnosis of scrub typhus is serology. It is widely known that demonstration of ≥4-fold rise in titers of antibody in paired sera is required for diagnosis. However, for guidance of initial treatment, there is a need for rapid diagnosis at the time of admission. Therefore, there is a need for standardized region specific cutoff titers at the time of admission. Materials and Methods: A total of 258 patients of all age groups with clinically suspected scrub typhus over a period of 24 months (October 2013-October 2015 were enrolled. Serum samples of these patients were subjected to immunofluorescent antibody (IFA for immunoglobulin M (IgM (Fuller Labs, USA with dilutions of 1:64, 1:128, 1:256, and 1:512. Serum samples of all 258 patients were subjected to IgM ELISA (Inbios Inc., USA. Any patient with response to antibiotics within 48 h accompanied by either presence of an eschar or positivity by polymerase chain reaction was taken as positive. Receiver operating characteristic (ROC curve was drawn to generate cutoff for these tests. Results: A total of 20 patients were diagnosed as cases of scrub typhus. The ROC curve analysis revealed a cutoff optical density value of 0.87 with sensitivity and specificity of 100% and 94.12%, respectively. ROC curve analysis of IFA revealed sensitivity and specificity of 100% and 93.5%, respectively at 1:64 dilution. Conclusion: Considering cost constraints, centers in and around New Delhi region can use the cutoffs we determined for the diagnosis of scrub typhus.

  14. Isolation, Culture, Functional Assays, and Immunofluorescence of Myofiber-Associated Satellite Cells.

    Science.gov (United States)

    Vogler, Thomas O; Gadek, Katherine E; Cadwallader, Adam B; Elston, Tiffany L; Olwin, Bradley B

    2016-01-01

    Adult skeletal muscle stem cells, termed satellite cells, regenerate and repair the functional contractile cells in adult skeletal muscle called myofibers. Satellite cells reside in a niche between the basal lamina and sarcolemma of myofibers. Isolating single myofibers and their associated satellite cells provides a culture system that partially mimics the in vivo environment. We describe methods for isolating and culturing intact individual myofibers and their associated satellite cells from the mouse extensor digitorum longus muscle. Following dissection and isolation of individual myofibers we provide protocols for myofiber transplantation, satellite cell transfection, immune detection of satellite cell antigens, and assays to examine satellite cell self-renewal and proliferation.

  15. Direct immunofluorescence and enzyme-linked immunosorbent assays for evaluating chlorinated hydrocarbon degrading bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Brigmon, R.L.; Franck, M.M.; Brey, J.; Fliermans, C.B. [Westinghouse Savannah River, Aiken, SC (United States). Environmental Biotechnology Section; Scott, D.; Lanclos, K. [Medical Coll. of Georgia, Augusta, GA (United States)

    1997-06-01

    Immunological procedures were developed to enumerate chlorinated hydrocarbon degrading bacteria. Polyclonal antibodies (Pabs) were produced by immunizing New Zealand white rabbits against 18 contaminant-degrading bacteria. These included methanotrophic and chlorobenzene (CB) degrading species. An enzyme-linked immunosorbent assay (ELISA) was used to test for specificity and sensitivity of the Pabs. Direct fluorescent antibodies (DFAs) were developed with these Pabs against select methanotrophic bacteria isolated from a trichloroethylene (TCE) contaminated landfill at the Savannah River Site (SRS) and cultures from the American Type Culture Collection (ATCC). Analysis of cross reactivity testing data showed some of the Pabs to be group specific while others were species specific. The threshold of sensitivity for the ELISA is 105 bacteria cells/ml. The DFA can detect as few as one bacterium per ml after concentration. Results from the DFA and ELISA techniques for enumeration of methanotrophic bacteria in groundwater were higher but not significantly different (P < 0.05) compared to indirect microbiological techniques such as MPN. These methods provide useful information on in situ community structure and function for bioremediation applications within 1--4 hours of sampling.

  16. Surface-biofunctionalized multicore/shell CdTe@SiO2 composite particles for immunofluorescence assay

    Science.gov (United States)

    Jing, Lihong; Li, Yilin; Ding, Ke; Qiao, Ruirui; Rogach, Andrey L.; Gao, Mingyuan

    2011-12-01

    Strongly fluorescent multicore/shell structured CdTe@SiO2 composite particles of ~ 50 nm were synthesized via the reverse microemulsion method by using CdTe quantum dots co-stabilized by thioglycolic acid and thioglycerol. The optical stability of the CdTe@SiO2 composite particles in a wide pH range, under prolonged UV irradiation in pure water, or in different types of physiological buffers was systematically investigated. Towards immunofluorescence assay, both poly(ethylene glycol) (PEG) and carboxyl residues were simultaneously grafted on the surface of the silanol-terminated CdTe@SiO2 composite particles upon further reactions with silane reagents bearing a PEG segment and carboxyl group, respectively, in order to suppress the nonspecific interactions of the silica particles with proteins and meanwhile introduce reactive moieties to the fluorescent particles. Agarose gel electrophoresis, dynamic light scattering and conventional optical spectroscopy were combined to investigate the effectiveness of the surface modifications. Via the surface carboxyl residue, various antibodies were covalently conjugated to the fluorescent particles and the resultant fluorescent probes were used in detecting cancer cells through both direct fluorescent antibody and indirect fluorescent antibody assays, respectively.

  17. A Comparison of Anti-Nuclear Antibody Quantification Using Automated Enzyme Immunoassays and Immunofluorescence Assays

    DEFF Research Database (Denmark)

    Baronaite, Renata; Engelhart, Merete; Mørk Hansen, Troels

    2014-01-01

    using IFA and automated EIA techniques. The IFA results generated by two independent laboratories were compared with the EIA results from antibodies against double-stranded DNA (dsDNA), from ANA screening, and from tests of the seven included subantigens. The final IFA and EIA results for 386 unique......, with Cohen's kappa value of 0.30 (95% confidence interval (CI) = 0.14-0.46), which decreased to 0.23 (95% CI = 0.06-0.40) when the results for dsDNA were omitted. The EIA method was less reliable for assessing nuclear and speckled reactivity patterns, whereas the IFA method presented difficulties detecting...... dsDNA and Ro activity. The automated EIA method was performed in a similar way to the conventional IFA method using HEp-2 cells; thus, automated EIA may be used as a screening test....

  18. Indirect immunofluorescence assay for the simultaneous detection of antibodies against clinically important old and new world hantaviruses.

    Directory of Open Access Journals (Sweden)

    Sabine Lederer

    Full Text Available In order to detect serum antibodies against clinically important Old and New World hantaviruses simultaneously, multiparametric indirect immunofluorescence assays (IFAs based on biochip mosaics were developed. Each of the mosaic substrates consisted of cells infected with one of the virus types Hantaan (HTNV, Puumala (PUUV, Seoul (SEOV, Saaremaa (SAAV, Dobrava (DOBV, Sin Nombre (SNV or Andes (ANDV. For assay evaluation, serum IgG and IgM antibodies were analyzed using 184 laboratory-confirmed hantavirus-positive sera collected at six diagnostic centers from patients actively or previously infected with the following hantavirus serotypes: PUUV (Finland, n=97; SEOV (China, n=5; DOBV (Romania, n=7; SNV (Canada, n=23; ANDV (Argentina and Chile, n=52. The control panel comprised 89 sera from healthy blood donors. According to the reference tests, all 184 patient samples were seropositive for hantavirus-specific IgG (n=177; 96% and/or IgM (n=131; 72%, while all control samples were tested negative. In the multiparametric IFA applied in this study, 183 (99% of the patient sera were IgG and 131 (71% IgM positive (accordance with the reference tests: IgG, 96%; IgM, 93%. Overall IFA sensitivity for combined IgG and IgM analysis amounted to 100% for all serotypes, except for SNV (96%. Of the 89 control sera, 2 (2% showed IgG reactivity against the HTNV substrate, but not against any other hantavirus. Due to the high cross-reactivity of hantaviral nucleocapsid proteins, endpoint titrations were conducted, allowing serotype determination in >90% of PUUV- and ANDV-infected patients. Thus, multiparametric IFA enables highly sensitive and specific serological diagnosis of hantavirus infections and can be used to differentiate PUUV and ANDV infection from infections with Murinae-borne hantaviruses (e.g. DOBV and SEOV.

  19. Aquaporin-4 autoantibodies in neuromyelitis optica spectrum disorders: comparison between tissue-based and cell-based indirect immunofluorescence assays

    Directory of Open Access Journals (Sweden)

    Chan Koon H

    2010-09-01

    Full Text Available Abstract Background Neuromyelitis optica spectrum disorders (NMOSD are severe central nervous system inflammatory demyelinating disorders (CNS IDD characterized by monophasic or relapsing, longitudinally extensive transverse myelitis (LETM and/or optic neuritis (ON. A significant proportion of NMOSD patients are seropositive for aquaporin-4 (AQP4 autoantibodies. We compared the AQP4 autoantibody detection rates of tissue-based indirect immunofluorescence assay (IIFA and cell-based IIFA. Methods Serum of Chinese CNS IDD patients were assayed for AQP4 autoantibodies by tissue-based IIFA using monkey cerebellum and cell-based IIFA using transfected HEK293 cells which express human AQP4 on their cell membranes. Results In total, 128 CNS IDD patients were studied. We found that 78% of NMO patients were seropositive for AQP4 autoantibodies by cell-based IIFA versus 61% by tissue-based IFA (p = 0.250, 75% of patients having relapsing myelitis (RM with LETM were seropositive by cell-based IIFA versus 50% by tissue-based IIFA (p = 0.250, and 33% of relapsing ON patients were seropositive by cell-based IIFA versus 22% by tissue-based IIFA (p = 1.000; however the differences were not statistically significant. All patients seropositive by tissue-based IIFA were also seropositive for AQP4 autoantibodies by cell-based IIFA. Among 29 NMOSD patients seropositive for AQP4 autoantibodies by cell-based IIFA, 20 (69% were seropositive by tissue-based IIFA. The 9 patients seropositive by cell-based IIFA while seronegative by tissue-based IIFA had NMO (3, RM with LETM (3, a single attack of LETM (1, relapsing ON (1 and a single ON attack (1. Among 23 NMO or RM patients seropositive for AQP4 autoantibodies by cell-based IIFA, comparison between those seropositive (n = 17 and seronegative (n = 6 by tissue-based IIFA revealed no differences in clinical and neuroradiological characteristics between the two groups. Conclusion Cell-based IIFA is slightly more sensitive

  20. An immunofluorescence assay for extracellular matrix components highlights the role of epithelial cells in producing a stable, fibrillar extracellular matrix

    Directory of Open Access Journals (Sweden)

    Omar S. Qureshi

    2017-10-01

    Full Text Available Activated fibroblasts are considered major drivers of fibrotic disease progression through the production of excessive extracellular matrix (ECM in response to signals from damaged epithelial and inflammatory cells. Nevertheless, epithelial cells are capable of expressing components of the ECM, cross-linking enzymes that increase its stability and are sensitive to factors involved in the early stages of fibrosis. We therefore wanted to test the hypothesis that epithelial cells can deposit ECM in response to stimulation in a comparable manner to fibroblasts. We performed immunofluorescence analysis of components of stable, mature extracellular matrix produced by primary human renal proximal tubular epithelial cells and renal fibroblasts in response to cytokine stimulation. Whilst fibroblasts produced a higher basal level of extracellular matrix components, epithelial cells were able to deposit significant levels of fibronectin, collagen I, III and IV in response to cytokine stimulation. In response to hypoxia, epithelial cells showed an increase in collagen IV deposition but not in response to the acute stress stimuli aristolochic acid or hydrogen peroxide. When epithelial cells were in co-culture with fibroblasts we observed significant increases in the level of matrix deposition which could be reduced by transforming growth factor beta (TGF-β blockade. Our results highlight the role of epithelial cells acting as efficient producers of stable extracellular matrix which could contribute to renal tubule thickening in fibrosis.

  1. Giardia and Cryptosporidium spp. dissemination during wastewater treatment and comparative detection via immunofluorescence assay (IFA), nested polymerase chain reaction (nested PCR) and loop mediated isothermal amplification (LAMP).

    Science.gov (United States)

    Gallas-Lindemann, Carmen; Sotiriadou, Isaia; Plutzer, Judit; Noack, Michael J; Mahmoudi, Mohammad Reza; Karanis, Panagiotis

    2016-06-01

    Environmental water samples from the Lower Rhine area in Germany were investigated via immunofluorescence assays (IFAs), nested polymerase chain reaction (nested PCR) and loop-mediated isothermal amplification (LAMP) to detect the presence of Giardia spp. (n=185) and Cryptosporidium spp. (n=227). The samples were concentrated through filtration or flocculation, and oocysts were purified via centrifugation through a sucrose density gradient. For all samples, IFA was performed first, followed by DNA extraction for the nested PCR and LAMP assays. Giardia cysts were detected in 105 samples (56.8%) by IFA, 62 samples (33.5%) by nested PCR and 79 samples (42.7%) by LAMP. Cryptosporidium spp. were detected in 69 samples (30.4%) by IFA, 95 samples (41.9%) by nested PCR and 99 samples (43.6%) by LAMP. According to these results, the three detection methods are complementary for monitoring Giardia and Cryptosporidium in environmental waters. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. IgA anti-Actin antibodies in children with celiac disease: comparison of immunofluorescence with Elisa assay in predicting severe intestinal damage

    Directory of Open Access Journals (Sweden)

    Mora Stefano

    2010-03-01

    Full Text Available Abstract Background Previous studies have demonstrated that the presence of serum IgA antibodies against actin filaments (AAA in patients with celiac disease (CD is strongly associated with mucosal damage and severe degrees of villous atrophy. The aims of the present study were (1 to verify the effectiveness of IgA-AAA in newly diagnosed CD patients in a clinical setting (2 to compare the immunofluorescence assay with ELISA assay; (3 to compare the correlation of our IgA anti-tissue transglutaminase antibodies (tTG-Ab class with mucosal intestinal lesions. Methods 90 patients underwent endoscopy and multiple biopsies for suspected CD on the basis of symptoms, in presence of positive tTG-Ab tests. Twenty biopsied and 25 not-biopsied subjects with negative tTG-Ab were tested as control groups. IgA-AAA assays were performed by indirect immunofluorescence using rat epithelial intestinal cells, and by ELISA with a commercial kit. tTG-Ab assay was a radio-binding assay. Intestinal specimens were collected by upper endoscopy and the histological study was done according to the Marsh's classification modified by Oberhuber (M/O. Auto-antibodies assays and histological evaluation have been performed blindly by skilled operators. Results CD diagnosis was confirmed in 82 patients (type I M/O in 2 patients, IIIA in 18 patients, IIIB in 29 patients and IIIC in 33 patients. Two patients with type 1 lesion in presence of positive tTG-Ab and abdominal complaints, started a gluten free diet. The rate of IgA-AAA positivity (sensitivity by IFI and ELISA in histologically proven celiac disease patients, were 5.5% and 25% patients in IIIA, 27.5% and 34.4% patients in IIIB, 78.8% and 75% in IIIC patients, respectively. Patients with normal or nearly normal mucosa, regardless of tTG-Ab status, presented negative IgA-AAA IFI assay. On the other hand, 1 patient with normal mucosa but positive tTG-Ab, also presented positive IgA-AAA ELISA. All healthy non biopsied

  3. Desempeño de la prueba de inmunofluorescencia directa en el diagnóstico del virus Influenza A(H1N1 Direct immunofluorescence assay performance in diagnosis of the Influenza A(H1N1 virus

    Directory of Open Access Journals (Sweden)

    Luis Pianciola

    2010-06-01

    Full Text Available El 25 de abril de 2009, a menos de un mes de la detección en México del primer humano con virus Influenza A(H1N1, la enfermedad ya se había propagado a más de 40 países superando los 10 000 casos notificados. Dada su naturaleza impredecible, este tipo de virus requiere métodos diagnósticos apropiados, confiables y seguros, pero que también estén al alcance de los laboratorios clínicos. Mediante el estudio de 291 muestras de pacientes con sospecha de infección por virus Influenza A(H1N1 en Neuquén, Argentina, el presente trabajo compara los dos métodos de diagnóstico utilizados simultáneamente: la prueba de inmunofluorescencia directa (DFA y la de reacción en cadena de la polimerasa en tiempo real (RT-PCR. La DFA dio una sensibilidad de 44,4%, especificidad de 99,6%, valor predictivo positivo de 95,2% y valor predictivo negativo de 90,7%. Los resultados positivos de la metodología pueden considerarse verdaderos positivos. Un resultado negativo no excluye la presencia del virus y la muestra debe examinarse mediante RT-PCR. Del total de 291 muestras, 45 resultaron positivas por RT-PCR y 21 por DFA.By 25 April 2009, less than one month after the first human with Influenza A(H1N1 virus was detected in Mexico, the disease had already spread to more than 40 countries, with over 10 000 cases reported. Due to its unpredictability, this type of virus requires appropriate, reliable, and safe diagnostic methods that are also accessible to clinical laboratories. Through the analysis of 291 samples taken from patients with suspected Influenza A(H1N1 virus infection in Neuquén, Argentina, this study compares the two diagnostic methods used simultaneously: direct immunofluorescence assay (DFA and real-time polymerase chain reaction (RT-PCR. DFA had a sensitivity of 44.4%, a specificity of 99.6%, a positive predictive value of 95.2%, and a negative predictive value of 90.7%. Positive results obtained with this method can be considered true

  4. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    Energy Technology Data Exchange (ETDEWEB)

    Birch, C J; Lehmann, N I; Hawker, A J; Marshall, J A; Gust, I D [Fairfield Hospital for Communicable Diseases, Victoria (Australia). Virology Dept.

    1979-07-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy.

  5. Comparison of enzyme-linked immunosorbent assay, radioimmunoassay, complement fixation, anticomplement immunofluorescence and passive haemaglutination techniques for detecting cytomegalovirus IgG antibody

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; Hannington, G; Bakir, T M.F.; Stern, H; Kangro, H; Griffiths, P D; Heath, R B [Saint George' s Hospital Medical School, London (UK); Saint Bartholomew' s Hospital, London (UK))

    1982-12-01

    The radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) techniques were found to be comparable in sensitivity and specificity for detecting cytomegalovirus IgG antibody, and 10 to 100 times more sensitive than complement-fixation (CF), anticomplement immunofluorescence (ACIF) and passive haemagglutination (PHA). In screening tests for antibody, the frequency of false-positive and -negative results was 0.6% for RIA and ELISA, 1.5% for CF, 1.6% for ACIF and 3.6% for PHA. PHA was the least satisfactory test, largely because of technical problems.

  6. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    International Nuclear Information System (INIS)

    Birch, C.J.; Lehmann, N.I.; Hawker, A.J.; Marshall, J.A.; Gust, I.D.

    1979-01-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy. (author)

  7. [Immunofluorescence assay with Crithidia luciliae for the detection of anti-DNA antibodies. Atypical images and their relationship with Chagas' disease and leishmaniasis].

    Science.gov (United States)

    Griemberg, Gloria; Ferrarotti, Nidia F; Svibel, Graciela; Ravelli, Maria R; Taranto, Nestor J; Malchiodi, Emilio L; Pizzimenti, Maria C

    2006-01-01

    Anti-native DNA antibodies can be detected by indirect immunofluorescence assay with Crithidia luciliae, displaying an annular image due to a kinetoplast containing double stranded DNA. Other structures such as membrane, flagellum and basal corpuscle can be stained as well, showing what is called atypical fluorescent images. As C. luciliae belongs to the Trypanosomatidae family, which include the human pathogens Trypanosoma cruzi and Leishmania spp., it was considered that these atypical images could be caused by cross-reactions. Serological studies for Chagas' disease were performed in 105 serum samples displaying atypical images. Sixty four percent of the samples from non endemic and 78.3% from endemic areas for Chagas' disease showed fluorescence in both, membrane and flagellum (joint image). Fifty samples from normal blood donors and 57 samples from patients with conective tissue diseases were tested with C. luciliae. None of them presented the joint image except for two patients with lupus who were also chagasic. In addition, 54 samples from chagasic patients were studied and all of them presented the joint image. We also studied 46 samples from patients with leishmaniasis from whom 28 were coinfected with T. cruzi. The joint image was observed in 88.0% of the samples with leishmaniasis and in 89.3% of the co-infected samples. The results suggest that C. luciliae could be used as an economical, and of low risk, alternative substrate for the serological diagnosis of Chagas' disease, even though it does not discriminate for Leishmania spp. infection. This study also suggests that whenever atypical images are observed in C. luciliae during the search for anti-DNA antibodies, it would be convenient to submit the patient to clinical and serological tests for the diagnosis of leishmaniosis and Chagas' disease.

  8. Anti-human neutrophil antigen-1a, -1b, and -2 antibodies in neonates and children with immune neutropenias analyzed by extracted granulocyte antigen immunofluorescence assay.

    Science.gov (United States)

    Onodera, Rie; Kurita, Emi; Taniguchi, Kikuyo; Karakawa, Shuhei; Okada, Satoshi; Kihara, Hirotaka; Fujii, Teruhisa; Kobayashi, Masao

    2017-11-01

    Anti-human neutrophil antigen (HNA) antibodies have been implicated in the development of neonatal alloimmune neutropenia (NAN) and autoimmune neutropenia (AIN). There are many conventional assay methods that detect anti-HNA antibodies. However, a method to measure multiple samples and detect several anti-HNA antibodies simultaneously is needed. We developed a new method, the extracted granulocyte antigen immunofluorescence assay (EGIFA), to analyze anti-HNA-1a, -1b, and -2 antibodies in sera. The results obtained by EGIFA were evaluated in comparison with those from several standard assay methods. Anti-HNA antibodies in serum samples from nine familial cases with suspected NAN (n = 19) and children with suspected AIN (n = 88) were also measured by EGIFA. The evaluation of nine serum samples with anti-HNA antibodies suggested that EGIFA demonstrated equivalent specificity and superior sensitivity to monoclonal antibody-specific immobilization of granulocyte antigens and had comparable sensitivity to the granulocyte indirect immunofluorescence test. EGIFA successfully detected anti-HNA-1a or -1b antibodies in seven of nine familial cases with suspected NAN. EGIFA detected anti-HNA antibodies in 40.9% of children with suspected AIN. Among them, isolated anti-HNA-1a or -1b antibody was detected in 4.5 or 12.5% of children, respectively, and anti-HNA-2 antibody was identified in 3.4% of children. The 30.8% (16 of 52) of children negative for anti-HNA antibody by EGIFA were positive for anti-HLA antibody. EGIFA facilitated the measurement of anti-HNA-1a, -1b, and/or -2 antibodies in sera. The prompt measurement of anti-HNA antibodies will improve the diagnosis and clinical management of patients with suspected NAN or AIN. © 2017 AABB.

  9. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    Science.gov (United States)

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  10. A Novel High-Content Immunofluorescence Assay as a Tool to Identify at the Single Cell Level γ-Globin Inducing Compounds.

    Directory of Open Access Journals (Sweden)

    Marta Durlak

    Full Text Available The identification of drugs capable of reactivating γ-globin to ameliorate β-thalassemia and Sickle Cell anemia is still a challenge, as available γ-globin inducers still have limited clinical indications. High-throughput screenings (HTS aimed to identify new potentially therapeutic drugs require suitable first-step-screening methods combining the possibility to detect variation in the γ/β globin ratio with the robustness of a cell line. We took advantage of a K562 cell line variant expressing β-globin (β-K562 to set up a new multiplexed high-content immunofluorescence assay for the quantification of γ- and β-globin content at single-cell level. The assay was validated by using the known globin inducers hemin, hydroxyurea and butyric acid and further tested in a pilot screening that confirmed HDACs as targets for γ-globin induction (as proved by siRNA-mediated HDAC3 knockdown and by treatment with HDACs inhibitors entinostat and dacinostat and identified Heme-oxygenases as novel candidate targets for γ-globin induction. Indeed, Heme-oxygenase2 siRNA knockdown as well as its inhibition by Tin protoporphyrin-IX (TinPPIX greatly increased γ-globin expression. This result is particularly interesting as several metalloporphyrins have already been developed for clinical uses and could be tested (alone or in combination with other drugs to improve pharmacological γ-globin reactivation for the treatment of β-hemoglobinopathies.

  11. Accuracy of molecular diagnostics in pemphigus and bullous pemphigoid: comparison of commercial and modified mosaic indirect immunofluorescence tests as well as enzyme-linked immunosorbent assays.

    Science.gov (United States)

    Gornowicz-Porowska, Justyna; Seraszek-Jaros, Agnieszka; Bowszyc-Dmochowska, Monika; Kaczmarek, Elżbieta; Pietkiewicz, Paweł; Bartkiewicz, Paweł; Dmochowski, Marian

    2017-02-01

    Pemphigus and bullous pemphigoid (BP) are identified by autoantibodies (abs) against desmoglein 1, 3 (DSG1/3) and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF) using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection) and modified (IgG4 detection) mosaic for indirect immunofluorescence (IIFc - IIF commercial, IIFm - IIF modified) and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP) molecular diagnostics. To compare diagnostic accuracy of commercial (IgG detection) and modified (IgG4 detection) mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher's exact test. There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1)/desmoglein3 (DSG3)/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.

  12. Accuracy of molecular diagnostics in pemphigus and bullous pemphigoid: comparison of commercial and modified mosaic indirect immunofluorescence tests as well as enzyme-linked immunosorbent assays

    Directory of Open Access Journals (Sweden)

    Justyna Gornowicz-Porowska

    2017-02-01

    Full Text Available Introduction : Pemphigus and bullous pemphigoid (BP are identified by autoantibodies (abs against desmoglein 1, 3 (DSG1/3 and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection and modified (IgG4 detection mosaic for indirect immunofluorescence (IIFc – IIF commercial, IIFm – IIF modified and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP molecular diagnostics. Aim : To compare diagnostic accuracy of commercial (IgG detection and modified (IgG4 detection mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Material and methods : Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher’s exact test. Results: There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1/desmoglein3 (DSG3/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. Conclusions : The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.

  13. A direct view by immunofluorescent comet assay (IFCA) of DNA damage induced by nicking and cutting enzymes, ionizing (137)Cs radiation, UV-A laser microbeam irradiation and the radiomimetic drug bleomycin.

    Science.gov (United States)

    Grigaravicius, Paulius; Rapp, Alexander; Greulich, Karl Otto

    2009-03-01

    In DNA repair research, DNA damage is induced by different agents, depending on the technical facilities of the investigating researchers. A quantitative comparison of different investigations is therefore often difficult. By using a modified variant of the neutral comet assay, where the histone H1 is detected by immunofluorescence [immunofluorescent comet assay (IFCA)], we achieve previously unprecedented resolution in the detection of fragmented chromatin and show that trillions of ultraviolet A photons (of a few eV), billions of bleomycin (BLM) molecules and thousands of gamma quanta (of 662 keV) generate, in first order, similar damage in the chromatin of HeLa cells. A somewhat more detailed inspection shows that the damage caused by 20 Gy ionizing radiation and by a single laser pulse of 10 microJ are comparable, while the damage caused by 12 microg/ml BLM depends highly on the individual cell. Taken together, this work provides a detailed view of DNA fragmentation induced by different treatments and allows comparing them to some extent, especially with respect to the neutral comet assay.

  14. ARIES nondestructive assay system operation and performance

    International Nuclear Information System (INIS)

    Cremers, Teresa L.; Hansen, Walter J.; Herrera, Gary D.; Nelson, David C.; Sampson, Thomas E.; Scheer, Nancy L.

    2000-01-01

    The ARIES (Advanced Recovery and Integrated Extraction System) Project is an integrated system at the Los Alamos Plutonium Facility for the dismantlement of nuclear weapons. The plutonium produced by the ARIES process was measured by an integrated nondestructive assay (NDA) system. The performance of the NDA systems was monitored by a measurement control program which is a part of a nuclear material control and accountability system. In this paper we will report the results of the measurements of the measurement control standards as well as an overview of the measurement of the ARIES process materials

  15. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  16. Systemic lupus erythematosus and the Crithidia luciliae immunofluorescent test

    International Nuclear Information System (INIS)

    Whitehouse, I.J.; Fehr, K.; Wagenhaeuser, F.J.

    1983-01-01

    A comparative study of the Crithidia luciliae immunofluorescence (CL-IF) assay and an adapted Farr radioimmunoassay (RIA), for the measurement of antibodies to native deoxyribonucleic acid, was performed using forty-two sera from patients with systematic lupus erythematosus (SLE) and another forty-two from patients with rheumatoid arthritis. Both assays were specific for SLE. The CL-IF assay was statistically significantly more sensitive than the adapted RIA assay. This significant difference was due to greater sensitivity of the CL-IF assay in the cases of sera from patients with SLE of slight activity. Additional advantages of the CL-IF assay were its use to classify the immunoglobulin types of the antibodies (most commonly IgG or IgM) and to measure complement-fixing antibodies to native deoxyribonucleic acid; it affords a simple method of selecting and following SLE patients at risk of developing severe renal disease. These advantages plus the simplicity and inexpensiveness of the CL-IF assay make it a useful tool, especially for use in small laboratories, for the study of antibodies to native deoxyribonucleic acid in patients with SLE. (orig.) [de

  17. Performance in the WIPP nondestructive assay performance demonstration program

    Energy Technology Data Exchange (ETDEWEB)

    Marcinkiewicz, C.J. [Consolidated Technical Services, Inc., Frederick, MD (United States); Connolly, M.J.; Becker, G.K. [Lockheed Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-11-01

    Measurement facilities performing nondestructive assay (NDA) of wastes intended for disposal at the United States Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) are required to demonstrate their ability to meet specific Quality Assurance Objectives (QAOs). This demonstration is performed, in part, by participation in the NDA Performance Demonstration Program (PDP). The PDP is funded and managed by the Carlsbad Area Office (CAO) of DOE and is conducted by the Idaho National Engineering Laboratory. It tests the characteristics of precision, system bias and/or total uncertainty through the measurement of variable, blind combinations of simulated waste drums and certified radioactive standards. Each facility must successfully participate in the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP using each different type of measurement system planned for use in waste characterization. The first cycle of the PDP was completed in July 1996 and the second is scheduled for completion by December 1996. Seven sites reported data in cycle 1 for 11 different measurement systems. This paper describes the design and operation of the PDP and provides the performance data from cycle 1. It also describes the preliminary results from cycle 2 and updates the status and future plans for the NDA PDP. 4 refs., 9 figs., 11 tabs.

  18. Accuracy of rapid influenza diagnostic test and immunofluorescence assay compared to real time RT-PCR in children with influenza A(H1N1pdm09 infection 

    Directory of Open Access Journals (Sweden)

    Aneta Nitsch-Osuch

    2012-10-01

    Full Text Available  Introduction:The influenza burden among children is underestimated. The aim of our study was to estimate the accuracy of the rapid influenza detection test (RIDT BD Directigen™ EZ Flu A B® and direct immunofluorescence assay (DFA used among children with influenza-like illness (ILI consulted in the ambulatory care clinic.Material/Methods:A total of 150 patients were enrolled in the study. Inclusion criteria were: age less than 59 months, presentation of ILI according to the CDC (Centers for Disease Control and Prevention definition (fever >37.8°C, cough and/or sore throat in the absence of another known cause of illness, duration of symptoms shorter than 96 hours. Two nasal swabs and one pharyngeal swab were obtained from patients and tested by RIDT, DFA and real time RT-PCR as the reference method.Results:For influenza A (H1N1pdm09 virus sensitivity of RIDT was 62.2�0(95�0CI 46.5–76.2� specificity 97.1�0(95�0CI 91.8–99.4� PPV 90.3�0(95�0CI 74.3–98� NPV 85.7�0(95�0CI 78.1–91.5� for DFA sensitivity was 60�0(95�0CI 51.9–63.2� specificity 96�0(95�0CI 88.7–98.8� PPV 93.1�0(95�0CI 80.5–98� NPV 72.7�0(95�0CI 67.2–74.9� Analysis of logistic regression revealed that the chance of receiving a true positive result of RIDT was twice as high when the test was conducted during the first 48 hours of symptoms (OR 0.40 vs OR 0.22.Conclusions:The accuracy of RIDT is comparable with DFA and both methods are very specific but moderately sensitive in diagnosis of influenza in young children. Both methods may be recommended for screening for influenza among children.

  19. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  20. Immunofluorescence-based screening identifies germ cell associated microRNA 302 as an antagonist to p63 expression

    DEFF Research Database (Denmark)

    Scheel, Andreas Hans Joachim; Beyer, Ulrike; Agami, Reuven

    2009-01-01

    The tumor suppressor homologue p63 is required for proper skin and limb development, but specific isoforms of it also act as a "guardian of the germline." To gain insight into the regulation of p63 expression, we performed immunofluorescence-based screening assays. Using a large collection of micro...

  1. Comparison of the performance of IFA, CFA, and ELISA assays for the serodiagnosis of acute Q fever by quality assessment.

    Science.gov (United States)

    Herremans, Tineke; Hogema, Boris M; Nabuurs, Marrigje; Peeters, Marcel; Wegdam-Blans, Marjolijn; Schneeberger, Peter; Nijhuis, Carla; Notermans, Daan W; Galama, Joep; Horrevorts, Anton; van Loo, Inge H M; Vlaminckx, Bart; Zaaijer, Hans L; Koopmans, Marion P; Berkhout, Hanneke; Socolovschi, Cristina; Raoult, Didier; Stenos, John; Nicholson, William; Bijlmer, Henk

    2013-01-01

    The indirect immunofluorescence assay (IFA) is considered the reference method for diagnosing Q fever, but serology is also performed by complement fixation assay (CFA) or enzyme-linked immunosorbent assay (ELISA). However, comparability between these assays is not clear, and therefore a quality assessment was performed. A total of 25 serum samples from negative controls, Q fever patients, and a serial diluted high-positive sample were analyzed in 10 Dutch laboratories. Six laboratories performed CFA, 5 performed IFA, and 5 performed ELISAs. Three international reference laboratories from Australia, France, and the USA also participated in this study. Qualitative values between laboratories using the same methods were within close range, and all 3 methods correctly identified acute Q fever patients. The IFA, ELISA, and CFA are all suitable serodiagnostic assays to diagnose acute Q fever, but the IFA remains an important tool in the follow-up of patients and in identifying patients at risk for developing chronic Q fever. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Performance characteristics of the ARCHITECT anti-HCV assay.

    Science.gov (United States)

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  3. Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

    Science.gov (United States)

    Ackerman, S B; Kelley, E A

    1983-03-01

    The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

  4. Highly specific and rapid immuno-fluorescent visualization and detection of E. coli O104:H4 with protein-A coated magnetic beads based LST-MUG assay.

    Science.gov (United States)

    Barizuddin, Syed; Balakrishnan, Baskar; Stringer, R Cody; Dweik, Majed

    2015-08-01

    A method combining immunomagnetic separation and fluorescent sensing was developed to detect Escherichia coli (E. coli) O104:H4. The antibody specific to E. coli O104:H4 was immobilized on protein A-coated magnetic beads. This protein-A-anti E. coli O104:H4 complex was used to bind Fluorescein IsoThioCyanate (FITC) labeled E. coli O104:H4 antigen (whole cell) on it. The goal was to achieve a fluorescently detectable protein-A-anti E. coli O104:H4-E. coli O104:H4 complex on the magnetic beads. Fluorescent microscopy was used to image the magnetic beads. The resulting fluorescence on the beads was due to the FITC labeled antigen binding on the protein-A-anti E. coli O104:H4 immobilized magnetic beads. This visually proves the antigen-antibody binding. The fluorescent imaging results were obtained in 2 h if the minimum available bacteria in the sample were at least 10(5) CFU/ml. If no fluorescence was observed on the magnetic beads during fluorescent imaging, it indicates the bacterial concentration in the sample to be too low for it to have bound to the magnetic beads and hence no detection was possible. To detect bacterial concentration less than 10(5) CFU/ml in the sample, an additional step was required for detection. The magnetic bead complex was added to the LST-MUG (lauryl sulfate tryptose-4-methylumbelliferyl-β-D-glucuronide), a signaling reporter. The E. coli O104:H4 grows in LST-MUG and releases β-glucuronidase enzyme. This enzyme cleaves the MUG substrate that produces 4-methylumbelliferone, a highly fluorescent species. This fluorescence was detected using a spectrofluorometer. The emission peak in the fluorescent spectrum was found to be at 450 nm. The lower and upper detection range for this LST-MUG assay was found to be 2.05×10(5)-4.09×10(8) CFU/ml. The results for the LST-MUG assay for concentrations below 10(5) CFU/ml were ascertained in 8h. The advantages of this technique include the specific detection of bacteria without an enrichment step and

  5. High-performance liquid chromatographic radioenzymatic assay for plasma catecyholamines

    International Nuclear Information System (INIS)

    Klaniecki, T.S.; Corder, C.N.; McDonald, R.H. Jr.; Feldman, J.A.

    1977-01-01

    A new assay method for plasma catecholamimes (CA) requiring only 50 μl has been developed, which uses high performance liquid chromatography (HPLC). The norepinephrine (NE), dopamine (D), and epinephrine (E) compounds found in plasma are radioactively o-methylated with S-[methyl- 3 H]-adenosyl-L-methionine ( 3 H-SAM) 3 H-SAM by the reaction of catechol-o-methyl transferase (COMT). The reaction is terminated and a standard mixture of nonradioactive o-methylated analogues of NE, D, and E is added to act as a carrier. Following separation by HPLC, the D,L-normetanephrine (NMN), 3-methoxy-4-hydroxyphenylethyl-amine or 3-methoxytyramine (3-MOT), and metanephrine (MN) radioactive peaks are collected which represent NE, D, and E, respectively. Then MNM and MN are oxidized to vanillin, and 3-MOT is acetylated. The products are subsequently separated by solvent extraction. This is necessary in order to avoid high radioactive blanks and to allow quantitation of the radioactivity by liquid scintillation spectrometry. The mean supine levels of NE, D, and E in normal subjects were respectively 182, 33, and 87 pg/ml of plasma. Similar assays on patients with pheochromocytoma revealed 797, 80, and 470 pg/ml

  6. Low cut-off values increase diagnostic performance of protein S assays

    NARCIS (Netherlands)

    Mulder, Rene; ten Kate, Min Ki; Kluin-Nelemans, Hanneke C.; Mulder, Andre B.

    Conflicting data have been reported on the accuracy of protein S (PS) assays for detection of hereditary PS deficiency. In this study we assessed the diagnostic performance of two total PS antigen assays, four free PS assays and three PS activity assays in a group of 28 heterozygous carriers of

  7. Pu-238 assay performance with the Canberra IQ3 system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, L.; Gillespie, B.; Seaman, G.

    1997-11-01

    Canberra Industries has recently completed a demonstration project at the Westinghouse Savannah River Site (WSRC) to characterize 55-gallon drums containing Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 waste to detection limits of less than 50 nCi/g using gamma assay techniques. This would permit reclassification of these drums from transuranic (TRU) waste to low-level waste (LLW). The instrument used for this assay was a Canberra IQ3 high sensitivity gamma assay system, mounted in a trailer. The results of the measurements demonstrate achievement of detection levels as low as 1 nCi/g for low density waste drums, and good correlation with known concentrations in several test drums. In addition, the data demonstrates significant advantages for using large area low-energy germanium detectors for achieving the lowest possible MDAs for gamma rays in the 80-250 keV range. 1 fig., 2 tabs.

  8. Performance of seven serological assays for diagnosing tularemia

    Science.gov (United States)

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  9. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  10. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  11. Inmunofluorescencia con Crithidia luciliae para la detección de anticuerpos anti-ADN: Imágenes atípicas y su relación con enfermedad de Chagas y leishmaniasis Immunofluorescence assay with Crithidia luciliae for the detection of anti-DNA antibodies: Atypical images and their relationship with Chagas’ disease and leishmaniasis

    Directory of Open Access Journals (Sweden)

    Gloria Griemberg

    2006-02-01

    Full Text Available Los anticuerpos anti-ADN nativo pueden detectarse por inmunofluorescencia indirecta con Crithidia luciliae, observándose tinción fluorescente anular del kinetoplasto que contiene ADN de doble cadena. En algunos casos pueden observarse imágenes fluorescentes en flagelo, membrana y corpúsculo basal, consideradas atípicas. Como C. luciliae pertenece a la familia Trypanosomatidae, que incluye patógenos para el hombre como Trypanosoma cruzi y Leishmaniaspp., se consideró que las imágenes atípicas pudieran deberse a reacciones cruzadas. Se realizaron estudios serológicos para Chagas a 105 muestras provenientes de zona endémica (Corrientes y no endémica (Buenos Aires para T. cruzi que presentaban imágenes atípicas con C. luciliae. La serología para Chagas resultó positiva en el 64.7% de las muestras de Buenos Aires y en el 78.3% de las de Corrientes que presentaban frente a C. luciliae imagen conjunta de membrana y flagelo. No presentaron la imagen conjunta ninguna de las muestras de dadores de sangre normales, ni de pacientes con enfermedades del tejido conectivo, excepto dos con lupus que también eran chagásicos. Todas las muestras de pacientes chagásicos analizadas frente a C. luciliae presentaron la imagen conjunta. Se estudiaron también 46 muestras de pacientes con leishmaniasis, 28 de ellos coinfectados con T. cruzi. La imagen conjunta se observó en el 88.0% de las muestras de leishmaniásicos y en el 78.5% de las de coinfectados. Los resultados sugieren que C. luciliae podría ser un sustrato alternativo, económico y de bajo riesgo para el diagnóstico serológico de enfermedad de Chagas, aunque no discrimina la infección por Leishmania. El hallazgo de la imagen conjunta en la detección de anti-ADN nativo señala la conveniencia de realizar en esos pacientes, estudios clínicos y de laboratorio para enfermedad de Chagas y leishmaniasis.Anti-native DNA antibodies can be detected by indirect immunofluorescence assay with

  12. The optimal condition of performing MTT assay for the determination of radiation sensitivity

    International Nuclear Information System (INIS)

    Hong, Semie; Kim, Il Han

    2001-01-01

    The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Four human cancer cell lines - PCI-1, SNU-1066, NCI-H63O and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy, For clonogenic assay, cells in 25 cm 2 flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for 10-14 days, For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. There was minimal variation in the values gained from these two methods with the standard deviation generally less than 5%, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the R 2 value of 0.975-0.992 between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than 30%). For cells with low plating efficiency (less than 30%), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was alter 6

  13. Biostatistical analysis of quantitative immunofluorescence microscopy images.

    Science.gov (United States)

    Giles, C; Albrecht, M A; Lam, V; Takechi, R; Mamo, J C

    2016-12-01

    Semiquantitative immunofluorescence microscopy has become a key methodology in biomedical research. Typical statistical workflows are considered in the context of avoiding pseudo-replication and marginalising experimental error. However, immunofluorescence microscopy naturally generates hierarchically structured data that can be leveraged to improve statistical power and enrich biological interpretation. Herein, we describe a robust distribution fitting procedure and compare several statistical tests, outlining their potential advantages/disadvantages in the context of biological interpretation. Further, we describe tractable procedures for power analysis that incorporates the underlying distribution, sample size and number of images captured per sample. The procedures outlined have significant potential for increasing understanding of biological processes and decreasing both ethical and financial burden through experimental optimization. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  14. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  15. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  16. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  17. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    Science.gov (United States)

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CVADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Schanfein, M.; Bonner, C.; Maez, R. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems` performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system`s performance for specific waste types, the standardized systems` performance be evaluated. 7 figs., 11 tabs.

  19. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    International Nuclear Information System (INIS)

    Schanfein, M.; Bonner, C.; Maez, R.

    1997-01-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems' performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system's performance for specific waste types, the standardized systems' performance be evaluated. 7 figs., 11 tabs

  20. Evaluation of reproductive performance using milk progesterone assay

    International Nuclear Information System (INIS)

    Reimers, T.J.

    1990-01-01

    Dairy herds (472) in the northeastern United States of America were surveyed to evaluate reproductive performance. Error of oestrus detection (>> 1 ng/mL of milk progesterone) on the day of insemination was 5.1% for 4558 cows. 'Standing' and 'riding other cows' were the most accurate signs of oestrus. Of cows in or near oestrus when inseminated, 28.1% were open three weeks later, 12.9% were probably open, and 59% were probably pregnant according to milk progesterone analysis. Post-partum days to first insemination and conception rates showed positive correlation. Concentrations of progesterone in milk samples collected 21 to 24 days after service allowed prediction with 88.6% accuracy that a cow was pregnant and with 93.9% accuracy that she was not. By rectal palpation, veterinarians predicted with 92.5% accuracy that a cow was pregnant. (author). 12 refs, 4 tabs

  1. Assay for dihydroorotase using high-performance liquid chromatography with radioactivity detection

    International Nuclear Information System (INIS)

    Mehdi, S.; Wiseman, J.S.

    1989-01-01

    An assay for measuring dihydroorotase activity was devised. Radiolabeled substrate and product were separated by high-performance liquid chromatography using a reverse-phase column with ion-pairing, and the radioactivity was quantitated by flow detection

  2. Epidermis area detection for immunofluorescence microscopy

    Science.gov (United States)

    Dovganich, Andrey; Krylov, Andrey; Nasonov, Andrey; Makhneva, Natalia

    2018-04-01

    We propose a novel image segmentation method for immunofluorescence microscopy images of skin tissue for the diagnosis of various skin diseases. The segmentation is based on machine learning algorithms. The feature vector is filled by three groups of features: statistical features, Laws' texture energy measures and local binary patterns. The images are preprocessed for better learning. Different machine learning algorithms have been used and the best results have been obtained with random forest algorithm. We use the proposed method to detect the epidermis region as a part of pemphigus diagnosis system.

  3. Evaluation of the Clinical Performance of the HPV-Risk Assay Using the VALGENT-3 Panel.

    Science.gov (United States)

    Polman, N J; Oštrbenk, A; Xu, L; Snijders, P J F; Meijer, C J L M; Poljak, M; Heideman, D A M; Arbyn, M

    2017-12-01

    Human papillomavirus (HPV) testing is increasingly being incorporated into cervical cancer screening. The Validation of HPV Genotyping Tests (VALGENT) is a framework designed to evaluate the clinical performance of various HPV tests relative to that of the validated and accepted comparator test in a formalized and uniform manner. The aim of this study was to evaluate the clinical performance of the HPV-Risk assay with samples from the VALGENT-3 panel and to compare its performance to that of the clinically validated Hybrid Capture 2 assay (HC2). The VALGENT-3 panel comprises 1,300 consecutive samples from women participating in routine cervical cancer screening and is enriched with 300 samples from women with abnormal cytology. DNA was extracted from original ThinPrep PreservCyt medium aliquots, and HPV testing was performed using the HPV-Risk assay by investigators blind to the clinical data. HPV prevalence was analyzed, and the clinical performance of the HPV-Risk assay for the detection of cervical intraepithelial neoplasia grade 3 or worse (CIN3+) and CIN2 or worse (CIN2+) relative to the performance of HC2 was assessed. The sensitivity of the HPV-Risk assay for the detection of CIN3+ was similar to that of HC2 (relative sensitivity, 1.00; 95% confidence interval [CI], 0.95 to 1.05; P = 1.000), but the specificity of the HPV-Risk assay was significantly higher than that of HC2 (relative specificity, 1.02; 95% CI, 1.01 to 1.04; P performance of the HPV-Risk assay for the detection of CIN3+ and CIN2+ was noninferior to that of HC2, with all P values being ≤0.006. In conclusion, the HPV-Risk assay demonstrated noninferiority to the clinically validated HC2 by the use of samples from the VALGENT-3 panel for test validation and comparison. Copyright © 2017 Polman et al.

  4. Evaluation of performance of human immunodeficiency virus antigen/antibody combination assays in Taiwan.

    Science.gov (United States)

    Chang, Chun-Kai; Kao, Cheng-Feng; Lin, Pi-Han; Huang, Hui-Lin; Ho, Shu-Yuan; Wong, Kuo-Chen; Lin, Bo-Chang; Yeh, Chang-Ching; Lee, Chia-Yeh; Kao, Chuan-Liang; Lee, Chun-Nan; Chang, Sui-Yuan; Yang, Jyh-Yuan

    2017-08-01

    The fourth-generation human immunodeficiency virus (HIV) combination assay, which can simultaneously detect the presence of anti-HIV antibody and HIV antigen, has been shown to shorten the window period in HIV diagnosis compared with the third-generation HIV antibody immunoassay. This study was aimed to determine the performance of HIV combination assays in Taiwan, where the HIV-1 seroprevalence is 0.007% and HIV-2 infection has never been reported. Performance of three fourth-generation HIV Ag/Ab combination assays (Dia.Pro, Wantai, and Bio-Rad) and one third-generation HIV Ab immunoassay (AxSYM HIV 1/2 gO) was assessed. A total of 152 specimens, including 86 confirmed HIV-seropositive and 66 HIV-seronegative samples, were used in the study. The sensitivity of four assays varied from 98.8% to 100%, and specificity varied from 98.5% to 100%. Performance of the 75 equivocal samples, the HIV status of which was confirmed later, in terms of negative prediction varied from 81.8% to 87.5%. The Bio-Rad and Dia.Pro assays exhibited higher sensitivity for the detection of p24 antigen among the three fourth-generation HIV combination assays. The three fourth-generation HIV Ag/Ab combination assays exhibited better sensitivity, specificity, and negative prediction than the third-generation HIV Ab immunoassay. Copyright © 2015. Published by Elsevier B.V.

  5. A European multicenter study on the analytical performance of the VERIS HBV assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  7. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    Science.gov (United States)

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay

  8. Análise TG-ROC de testes de imunofluorescência no diagnóstico de leishmaniose visceral canina Análisis TG-ROC de pruebas de inmunofluorescencia en el diagnóstico de leishmaniasis visceral canina TG-ROC analysis of immunofluorescence assays in canine visceral leishmaniasis diagnosis

    Directory of Open Access Journals (Sweden)

    Rita Maria da Silva

    2009-12-01

    costo-beneficio.OBJECTIVE: To analyze the accuracy of the diagnosis of two protocols of indirect immunofluorescence assays for canine visceral leishmaniasis. METHODS: Dogs from the seroepidemiological survey conducted in an endemic area of the cities of Araçatuba and Andradina, in Northwestern São Paulo state, in 2003, and in a non-endemic area of the metropolitan region of São Paulo, were used to assess two protocols of indirect immunofluorescence assay (IFA for leishmaniasis: one using a Leishmania major heterologous antigen (IFA-BM and another using a Leishmania chagasi homologous antigen (IFA-CH. Two-graph receiver operating characteristic (TG-ROC analysis was used to estimate accuracy. TG-ROC analysis compared 1:20 dilution readings of the homologous antigen (IFA-CH, considered as reference test, with IFA-BM dilutions (heterologous antigen. RESULTS: The 1:20 dilution used in the IFA-CH test showed the best contingency coefficient (0.755 and the highest strength of association between the two variables studied (chi-square=124.3. Thus, it was considered the test reference dilution in comparisons with different IFA-BM test dilutions. The best IFA-BM results were obtained from 1:40 dilutions with the best contingency coefficient (0.680 and highest strength of association (chi-square=80.8. With the change in the cut-off point, recommended for the IFA-BM 1:40 dilution in this analysis, the specificity parameter value rose from 57.5% to 97.7%, even though the 1:80 dilution showed the best sensitivity estimate (80.2%, with the new cut-off point. CONCLUSIONS: TG-ROC analysis can provide important information about diagnostic tests, in addition to offering suggestions on cut-off points that can improve test sensitivity and specificity estimates and assessing these tests in terms of the best cost-benefit ratio.

  9. Direct immunofluorescence for the diagnosis of legionellosis

    Directory of Open Access Journals (Sweden)

    David JM Haldane

    1993-01-01

    Full Text Available Culture and direct immunofluorescent microscopy (DFA results for Legionella pneumophila were reviewed over a two-year period. In the first year, a positive result was defined as having at least one morphologically typical fluorescing organism. In the second year, a positive was defined as at least five typical fluorescing organisms. Despite these stricter criteria and other measures to reduce the possibility of reagent contamination, there was no statistically significant difference in the sensitivity or specificity of the DFA in the two years for sputa, deep specimens or overall. Of 37 sputum specimens from infected patients, 16 were positive on DFA. Thirty-two of 38 positive patients were detected by sputum culture. DFA can provide rapid diagnostic information but cannot be used to rule out the diagnosis. Sputum is a useful specimen for the initial laboratory investigation of patients with legionellosis.

  10. Anticoagulants Influence the Performance of In Vitro Assays Intended for Characterization of Nanotechnology-Based Formulations

    Directory of Open Access Journals (Sweden)

    Edward Cedrone

    2017-12-01

    Full Text Available The preclinical safety assessment of novel nanotechnology-based drug products frequently relies on in vitro assays, especially during the early stages of product development, due to the limited quantities of nanomaterials available for such studies. The majority of immunological tests require donor blood. To enable such tests one has to prevent the blood from coagulating, which is usually achieved by the addition of an anticoagulant into blood collection tubes. Heparin, ethylene diamine tetraacetic acid (EDTA, and citrate are the most commonly used anticoagulants. Novel anticoagulants such as hirudin are also available but are not broadly used. Despite the notion that certain anticoagulants may influence assay performance, a systematic comparison between traditional and novel anticoagulants in the in vitro assays intended for immunological characterization of nanotechnology-based formulations is currently not available. We compared hirudin-anticoagulated blood with its traditional counterparts in the standardized immunological assay cascade, and found that the type of anticoagulant did not influence the performance of the hemolysis assay. However, hirudin was more optimal for the complement activation and leukocyte proliferation assays, while traditional anticoagulants citrate and heparin were more appropriate for the coagulation and cytokine secretion assays. The results also suggest that traditional immunological controls such as lipopolysaccharide (LPS are not reliable for understanding the role of anticoagulant in the assay performance. We observed differences in the test results between hirudin and traditional anticoagulant-prepared blood for nanomaterials at the time when no such effects were seen with traditional controls. It is, therefore, important to recognize the advantages and limitations of each anticoagulant and consider individual nanoparticles on a case-by-case basis.

  11. Performance of the Xpert HIV-1 Viral Load Assay: a Systematic Review and Meta-analysis.

    Science.gov (United States)

    Nash, Madlen; Huddart, Sophie; Badar, Sayema; Baliga, Shrikala; Saravu, Kavitha; Pai, Madhukar

    2018-04-01

    Viral load (VL) is the preferred treatment-monitoring approach for HIV-positive patients. However, more rapid, near-patient, and low-complexity assays are needed to scale up VL testing. The Xpert HIV-1 VL assay (Cepheid, Sunnyvale, CA) is a new, automated molecular test, and it can leverage the GeneXpert systems that are being used widely for tuberculosis diagnosis. We systematically reviewed the evidence on the performance of this new tool in comparison to established reference standards. A total of 12 articles (13 studies) in which HIV patient VLs were compared between Xpert HIV VL assay and a reference standard VL assay were identified. Study quality was generally high, but substantial variability was observed in the number and type of agreement measures reported. Correlation coefficients between Xpert and reference assays were high, with a pooled Pearson correlation ( n = 8) of 0.94 (95% confidence interval [CI], 0.89, 0.97) and Spearman correlation ( n = 3) of 0.96 (95% CI, 0.86, 0.99). Bland-Altman metrics ( n = 11) all were within 0.35 log copies/ml of perfect agreement. Overall, Xpert HIV-1 VL performed well compared to current reference tests. The minimal training and infrastructure requirements for the Xpert HIV-1 VL assay make it attractive for use in resource-constrained settings, where point-of-care VL testing is most needed. Copyright © 2018 Nash et al.

  12. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  13. An Automatic Indirect Immunofluorescence Cell Segmentation System

    Directory of Open Access Journals (Sweden)

    Yung-Kuan Chan

    2014-01-01

    Full Text Available Indirect immunofluorescence (IIF with HEp-2 cells has been used for the detection of antinuclear autoantibodies (ANA in systemic autoimmune diseases. The ANA testing allows us to scan a broad range of autoantibody entities and to describe them by distinct fluorescence patterns. Automatic inspection for fluorescence patterns in an IIF image can assist physicians, without relevant experience, in making correct diagnosis. How to segment the cells from an IIF image is essential in developing an automatic inspection system for ANA testing. This paper focuses on the cell detection and segmentation; an efficient method is proposed for automatically detecting the cells with fluorescence pattern in an IIF image. Cell culture is a process in which cells grow under control. Cell counting technology plays an important role in measuring the cell density in a culture tank. Moreover, assessing medium suitability, determining population doubling times, and monitoring cell growth in cultures all require a means of quantifying cell population. The proposed method also can be used to count the cells from an image taken under a fluorescence microscope.

  14. The Davies-Gray titration for the assay of uranium in nuclear materials: a performance study

    International Nuclear Information System (INIS)

    Bickel, M.

    1997-01-01

    An interlaboratory comparison in two phases was organized to assess the precision and accuracy concerning the assay of uranium in nuclear materials by the potentiometric titration method. This contribution presents the results of this exercise in terms of method performance. Variations to be expected between different laboratories and within a single laboratory are estimated. In general, the method proved again very reliable. (orig.)

  15. How to best freeze liver samples to perform the in vivo mammalian alkaline comet assay

    Directory of Open Access Journals (Sweden)

    José Manuel Enciso Gadea

    2015-06-01

    None of the different methods used was capable of giving good results, except immersing the liver samples in liquid nitrogen, followed by Jackson’s et al. (2013 thawing protocol, suggesting that the thawing process may be as critical as the freezing process. To sum up, these results highlight the importance of deepening the possibility to perform the comet assay with frozen tissue.

  16. Performance Assessment of a Trypanosoma cruzi Chimeric Antigen in Multiplex Liquid Microarray Assays.

    Science.gov (United States)

    Santos, Fred Luciano Neves; Celedon, Paola Alejandra Fiorani; Zanchin, Nilson Ivo Tonin; Leitolis, Amanda; Crestani, Sandra; Foti, Leonardo; de Souza, Wayner Vieira; Gomes, Yara de Miranda; Krieger, Marco Aurélio

    2017-10-01

    Diagnosing chronic Chagas disease (CD) requires antibody-antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi -specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti- T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania , a pathogen with high similarity to T. cruzi , showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland-Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD. Copyright © 2017 American Society for Microbiology.

  17. Short Communication: Comparison of Maxim and Sedia Limiting Antigen Assay Performance for Measuring HIV Incidence.

    Science.gov (United States)

    Schlusser, Katherine E; Konikoff, Jacob; Kirkpatrick, Allison R; Morrison, Charles; Chipato, Tsungai; Chen, Pai-Lien; Munjoma, Marshall; Eshleman, Susan H; Laeyendecker, Oliver

    2017-06-01

    Accurate methods for cross-sectional incidence estimation are needed for HIV prevention research. The Limiting Antigen Avidity (LAg-Avidity) assay has been marketed by two vendors, Maxim Biomedical and Sedia BioSciences Corporation. Performance differences between the two versions of the assay are unknown. We tested a total 1,410 treatment-naive samples with both versions of the assay. The samples came from 176 seroconverters from the Zimbabwe Hormonal Contraception and HIV Study. The correlation between the two versions of the assay was 0.93 for the optical density (OD) and 0.86 for the normalized OD. As the difference was more pronounced for the normalized OD, the difference in assays can be attributed to the calibrators. The mean duration of recent infection (MDRI), the average time individuals infected 1,000 copies/ml. The MDRI was 137 days for Sedia and 157 days for Maxim, with a difference of 20 days (95% CI 11-30). The MDRIs decreased to 102 and 120 days with the inclusion of a viral load cutoff of >1,000 copies/ml. These results imply that use of the Sedia LAg-Avidity will result in estimates of incidence ∼13% lower than those using the Maxim LAg-Avidity.

  18. Evaluation of the Thermo Scientific SureTect Salmonella species assay. AOAC Performance Tested Method 051303.

    Science.gov (United States)

    Cloke, Jonathan; Clark, Dorn; Radcliff, Roy; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Salmonella species Assay is a new real-time PCR assay for the detection of Salmonellae in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Salmonella species Assay in comparison to the reference method detailed in International Organization for Standardization 6579:2002 in a variety of food matrixes, namely, raw ground beef, raw chicken breast, raw ground pork, fresh bagged lettuce, pork frankfurters, nonfat dried milk powder, cooked peeled shrimp, pasteurized liquid whole egg, ready-to-eat meal containing beef, and stainless steel surface samples. With the exception of liquid whole egg and fresh bagged lettuce, which were tested in-house, all matrixes were tested by Marshfield Food Safety, Marshfield, WI, on behalf of Thermo Fisher Scientific. In addition, three matrixes (pork frankfurters, lettuce, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled laboratory study by the University of Guelph, Canada. No significant difference by probability of detection or McNemars Chi-squared statistical analysis was found between the candidate or reference methods for any of the food matrixes or environmental surface samples tested during the validation study. Inclusivity and exclusivity testing was conducted with 117 and 36 isolates, respectively, which demonstrated that the SureTect Salmonella species Assay was able to detect all the major groups of Salmonella enterica subspecies enterica (e.g., Typhimurium) and the less common subspecies of S. enterica (e.g., arizoniae) and the rarely encountered S. bongori. None of the exclusivity isolates analyzed were detected by the SureTect Salmonella species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation (enrichment time

  19. Improved assay for thymine base damage in E. coli using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Claycamp, H.G.

    1985-01-01

    A simple high performance liquid chromatography (HPLC) technique has been established for the simultaneous assay of thymine and thymidine radiation damage products. The HPLC procedure uses an isocratic mobile phase of 4% acetonitrile in 0.2 M ammonium dihydrogen phosphate (pH 5.0), a reversed-phase octadecylsilicate (5 micro-spherical packing) 0.45 x 25 cm column, and a variable wavelength UV detector. This procedure affords much better resolution than other published procedures that use 10 micron columns or separate assays for bases and nucleosides. For example, irradiation of 5 x 10 -3 M thymidine solutions have been performed to calibrate the system for base damage assays in E. coli. This yields up to 15 resolvable residues within 20 minutes. Sensitivity of the system (at 2210 nm) for 5,6- dihydrothymine (DHT) is about 10 -10 moles. Preliminary results show that this translates to about 0.4 DHT residues per 10 6 daltons of E. coli DNA. This is comparable to the sensitivities of monoclonal assays to thymine damage products that have recently been reported by others. Since it is feasible that the sensitivity of this system can be improved by 2-3 times, this HPLC technique should provide a simple and rapid means of detecting E. coli base damage release and base damage in nucleoside hydrolysates of DNA

  20. Point of Care Cardiac Troponin Assay Analytical Performances for their Use in Clinical Routine.

    Science.gov (United States)

    Dupuy, Anne M; Baillet, Solenne; Dumont, Richard; Giraud, Isabelle; Badiou, Stephanie; Bargnoux, Anne S; Kuster, Nils; Roubille, Francois; Cristol, Jean Paul

    2017-04-01

    We report the analytical and clinical performances of the Alere Triage Cardiac3© Panel on the Triage MeterPro© instrument, comparing concordance with hs-cTnT results from central laboratory above the respective 99th percentiles and determining the clinical sensitivity within the framework of AMI. The concordance was obtained with these two methods among unselected patients admitted to both the emergency and cardiology departments. The LoD of the assay is 0.010 µg/L. At 99th percentile (0.02 µg/L) the CV was found to be 18%, below the clinically acceptable cutoff of 20%. In the overall population, ROC AUC was not significantly different between the central laboratory assay and POC assay, with 0.952 (95% CI, 0.918 - 0.952) for hs-cTnT concentrations at presentation and 0.953 (95% CI, 0.912 - 0.953) for cTnI. Sensitivity and specificity of hs-cTnT vs. cTnI for AMI (n = 32) were 97% and 78% vs. 91% and 86%, respectively. Our results indicated 90.4% concordance between the two methods using the 99th percentile specific for each assay. The Kappa coefficient was higher than 0.75, and the strength of agreement could be considered to be good. The results of cTnI Alere assays provide similar clinical classification of patients, particularly for the AMI group as compared to the central laboratory hs-cTnT assay and could be suitable for clinical in accordance with the recommendations of Global Task Force guidelines.

  1. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  2. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    Science.gov (United States)

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  3. Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.

    Science.gov (United States)

    White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin

    2018-05-15

    Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia

  4. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  5. Performance of the Xpert HPV assay in women attending for cervical screening

    Directory of Open Access Journals (Sweden)

    Jack Cuzick

    2015-12-01

    Full Text Available Objectives: This study evaluated the Xpert HPV Assay in women attending screening in general practice by comparing Xpert with two established HPV tests, cytology and histology. Methods: A prospective study in women aged 20–60 years attending screening in Bristol, Edinburgh and London using residual Preservcyt cytology samples. Sample order was randomised between Roche cobas4800 and Cepheid Xpert assays with Qiagen hc2 third. Results: 3408 cases were included in the primary analysis. Positivity for Xpert was 19.6%, cobas 19.2% and hc2 19.9% with high concordance (kappa=86.8% vs cobas, 81.55 vs hc2. Xpert, cobas and hc2 showed similar sensitivity (98.7%, 97.5%, 98.7% for CIN2+. All pairwise comparisons had high concordance (Kappa ≥0.78 with any abnormal cytology. Xpert and hc2 were positive for all cases of ≥moderate dyskaryosis (N=63, cobas was negative in two. Histology was available for 172 participants. 79 reported CIN2+, 47 CIN3+. All CIN3+ was positive on Xpert and hc2 and one case negative for cobas. One case of CIN2 was negative for all assays. Conclusions: The performance of Xpert HPV Assay in a general screening population is comparable to established HPV tests. It offers simplicity of testing, flexibility with non-batching of individual samples and rapid turnaround time. Keywords: Human papillomavirus, Xpert, Cervical screening, HPV testing

  6. Combined high-performance liquid chromatography/32P-postlabeling assay of N7-methyldeoxyguanosine

    International Nuclear Information System (INIS)

    Shields, P.G.; Povey, A.C.; Wilson, V.L.; Weston, A.; Harris, C.C.

    1990-01-01

    A highly sensitive and specific assay for the detection of N7-methyl-2'-deoxyguanosine (N7methyldG) has been developed by combining high-performance liquid chromatography, 32 P-postlabeling, and nucleotide chromatography. Separation of normal nucleotides and adducts by high-performance liquid chromatography and then combining a portion of 2'-deoxyguanosine to the N7methyldG allows for quantitation using an internal standard. The directly determined molar ratio is not subject to errors in digestion, variable ATP-specific activity, or assumptions in relative adduct-labeling efficiency. The detection limit was one N7methyldG adduct in 10(7) unmodified 2'-deoxyguanosine bases. N7methyldG adducts have been detected in 5 human lung samples in which O6-methyl-2'-deoxyguanosine adducts had been previously determined. The mean ratio of N7methyldG to O6-methyl-2'-deoxyguanosine was determined to be approximately 10. The current assay complements the high-performance liquid chromatography/ 32 P-postlabeling assay for O6-methyl-2'-deoxyguanosine and increases the detection sensitivity of DNA methylated by exogenous alkylating agents

  7. Automated Processing and Evaluation of Anti-Nuclear Antibody Indirect Immunofluorescence Testing.

    Science.gov (United States)

    Ricchiuti, Vincent; Adams, Joseph; Hardy, Donna J; Katayev, Alexander; Fleming, James K

    2018-01-01

    Indirect immunofluorescence (IIF) is considered by the American College of Rheumatology (ACR) and the international consensus on ANA patterns (ICAP) the gold standard for the screening of anti-nuclear antibodies (ANA). As conventional IIF is labor intensive, time-consuming, subjective, and poorly standardized, there have been ongoing efforts to improve the standardization of reagents and to develop automated platforms for assay incubation, microscopy, and evaluation. In this study, the workflow and performance characteristics of a fully automated ANA IIF system (Sprinter XL, EUROPattern Suite, IFA 40: HEp-20-10 cells) were compared to a manual approach using visual microscopy with a filter device for single-well titration and to technologist reading. The Sprinter/EUROPattern system enabled the processing of large daily workload cohorts in less than 8 h and the reduction of labor hands-on time by more than 4 h. Regarding the discrimination of positive from negative samples, the overall agreement of the EUROPattern software with technologist reading was higher (95.6%) than when compared to the current method (89.4%). Moreover, the software was consistent with technologist reading in 80.6-97.5% of patterns and 71.0-93.8% of titers. In conclusion, the Sprinter/EUROPattern system provides substantial labor savings and good concordance with technologist ANA IIF microscopy, thus increasing standardization, laboratory efficiency, and removing subjectivity.

  8. Automated Processing and Evaluation of Anti-Nuclear Antibody Indirect Immunofluorescence Testing

    Directory of Open Access Journals (Sweden)

    Vincent Ricchiuti

    2018-05-01

    Full Text Available Indirect immunofluorescence (IIF is considered by the American College of Rheumatology (ACR and the international consensus on ANA patterns (ICAP the gold standard for the screening of anti-nuclear antibodies (ANA. As conventional IIF is labor intensive, time-consuming, subjective, and poorly standardized, there have been ongoing efforts to improve the standardization of reagents and to develop automated platforms for assay incubation, microscopy, and evaluation. In this study, the workflow and performance characteristics of a fully automated ANA IIF system (Sprinter XL, EUROPattern Suite, IFA 40: HEp-20-10 cells were compared to a manual approach using visual microscopy with a filter device for single-well titration and to technologist reading. The Sprinter/EUROPattern system enabled the processing of large daily workload cohorts in less than 8 h and the reduction of labor hands-on time by more than 4 h. Regarding the discrimination of positive from negative samples, the overall agreement of the EUROPattern software with technologist reading was higher (95.6% than when compared to the current method (89.4%. Moreover, the software was consistent with technologist reading in 80.6–97.5% of patterns and 71.0–93.8% of titers. In conclusion, the Sprinter/EUROPattern system provides substantial labor savings and good concordance with technologist ANA IIF microscopy, thus increasing standardization, laboratory efficiency, and removing subjectivity.

  9. Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

    Science.gov (United States)

    Carr, R A; Foster, R T; Bhanji, N H

    1991-09-01

    A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the organic layer, samples were derivatized with a solution of S-(+)-1-(1-naphthyl)ethyl isocyanate (NEIC). The resulting diastereomers were chromatographed with normal-phase HPLC with chloroform:hexane:methanol [65:33:2 (v/v)] as the mobile phase at a flow rate of 2 ml/min. The fluorescence detection wavelength was set at 220 nm for excitation with no emission filter. The suitability of the assay for pharmacokinetic studies was determined by measuring STL enantiomers in the plasma of a healthy subject after administration of a single 160-mg oral, racemic dose of STL.

  10. Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

    Science.gov (United States)

    Eshleman, Susan H; Piwowar-Manning, Estelle; Sivay, Mariya V; Debevec, Barbara; Veater, Stephanie; McKinstry, Laura; Bekker, Linda-Gail; Mannheimer, Sharon; Grant, Robert M; Chesney, Margaret A; Coates, Thomas J; Koblin, Beryl A; Fogel, Jessica M

    Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection. To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection. Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay. Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay. Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) consists of a series of tests conducted on a regular frequency to evaluate the capability for nondestructive assay of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed with TRU waste characterization systems. Measurement facility performance will be demonstrated by the successful analysis of blind audit samples according to the criteria set by this Program Plan. Intercomparison between measurement groups of the DOE complex will be achieved by comparing the results of measurements on similar or identical blind samples reported by the different measurement facilities. Blind audit samples (hereinafter referred to as PDP samples) will be used as an independent means to assess the performance of measurement groups regarding compliance with established Quality Assurance Objectives (QAOs). As defined for this program, a PDP sample consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components, once manufactured, will be secured and stored at each participating measurement facility designated and authorized by Carlsbad Area Office (CAO) under secure conditions to protect them from loss, tampering, or accidental damage

  12. Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults.

    Science.gov (United States)

    Li, Danni; Radulescu, Angela; Shrestha, Rupendra T; Root, Matthew; Karger, Amy B; Killeen, Anthony A; Hodges, James S; Fan, Shu-Ling; Ferguson, Angela; Garg, Uttam; Sokoll, Lori J; Burmeister, Lynn A

    2017-09-26

    Biotinylated antibodies and analogues, with their strong binding to streptavidin, are used in many clinical laboratory tests. Excess biotin in blood due to supplemental biotin ingestion may affect biotin-streptavidin binding, leading to potential clinical misinterpretation. However, the degree of interference remains undefined in healthy adults. To assess performance of specific biotinylated immunoassays after 7 days of ingesting 10 mg/d of biotin, a dose common in over-the-counter supplements for healthy adults. Nonrandomized crossover trial involving 6 healthy adults who were treated at an academic medical center research laboratory. Administration of 10 mg/d of biotin supplementation for 7 days. Analyte concentrations were compared with baseline (day 0) measures on the seventh day of biotin treatment and 7 days after treatment had stopped (day 14). The 11 analytes included 9 hormones (ie, thyroid-stimulating hormone, total thyroxine, total triiodothyronine, free thyroxine, free triiodothyronine, parathyroid hormone, prolactin, N-terminal pro-brain natriuretic peptide, 25-hydroxyvitamin D) and 2 nonhormones (prostate-specific antigen and ferritin). A total of 37 immunoassays for the 11 analytes were evaluated on 4 diagnostic systems, including 23 assays that incorporated biotin and streptavidin components and 14 assays that did not include biotin and streptavidin components and served as negative controls. Among the 2 women and 4 men (mean age, 38 years [range, 31-45 years]) who took 10 mg/d of biotin for 7 days, biotin ingestion-associated interference was found in 9 of the 23 (39%) biotinylated assays compared with none of the 14 nonbiotinylated assays (P = .007). Results from 5 of 8 biotinylated (63%) competitive immunoassays tested falsely high and results from 4 out of 15 (27%) biotinylated sandwich immunoassays tested falsely low. In this preliminary study of 6 healthy adult participants and 11 hormone and nonhormone analytes measured by 37 immunoassays

  13. Estimation of antibodies to human cytomegalovirus by immunofluorescence and radioimmunoassay

    International Nuclear Information System (INIS)

    Jankowski, M.; Gut, W.; Nawrocka, E.

    1980-01-01

    The 125 I labelled IgG fraction against rabbit IgG of goat origin was employed for the detection of CMV IgG and IgM antibodies in the double indirect radioimmunoassay. The results were compared with those obtained in complement fixation, indirect immunofluorescence and anti-complement immunofluorescence tests. The application of labelled anti-fc antisera, instead of antisera against whole IgG in the tests for detection of specific CMV IgG antibody resulted in increased sensitivity of radioimmunoassay and reduction of non-specific cytoplasmatic reactions in preparations stained by indirect immunofluorescence. The absorption of sera with protein A rich staphylococci and aggregates to immunoglobulin eliminated unwanted secondary IgM staining caused by rheumatoid factors both in indirect immunofluorescence and radioimmunoassay tests for CMV antibodies. (author)

  14. Relative performance of a TGS for the assay of drummed waste as function of collimator opening

    International Nuclear Information System (INIS)

    Kane, S.C.; Croft, S.; McClay, P.; Venkataraman, R.; Villani, M.F.

    2007-01-01

    Improving the safety, accuracy and overall cost effectiveness of the processes and methods used to characterize and handle radioactive waste is an on-going mission for the nuclear industry. An important contributor to this goal is the development of superior non-destructive assay instruments. The Tomographic Gamma Scanner (TGS) is a case in point. The TGS applies low spatial resolution experimental computed tomography (CT) linear attenuation coefficient maps with three-dimensional high-energy resolution single photon emission reconstructions. The results are presented as quantitative matrix attenuation corrected images and assay values for gamma-emitting radionuclides. Depending on a number of operational factors, this extends the diversity of waste forms that can be assayed, to a given accuracy, to items containing more heterogeneous matrix distributions and less uniform emission activity distributions. Recent advances have significantly extended the capability to a broader range of matrix density and to a wider dynamic range of surface dose rate. Automated systems sense the operational conditions, including the container type, and configure themselves accordingly. The TGS also provides a flexible data acquisition platform and can be used to perform far-field style measurements, classical segmented gamma scanner measurements, or to implement hybrid methods, such as reconstructions that use a priori knowledge to constrain the image reconstruction or the underlying energy dependence of the attenuation. A single, yet flexible, general purpose instrument of this kind adds several tiers of strategic and tactical value to facilities challenged by a diverse and difficult to assay waste streams. The TGS is still in the early phase of industrial uptake. There are only a small number of general purpose TGS systems operating worldwide, most being configured to automatically select between a few configurations appropriate for routine operations. For special investigations

  15. Utility and diagnostic performance of Mycobacterium tuberculosis complex by two immunochromatographic assays as compared with the molecular Genotype assay in Nigeria

    Directory of Open Access Journals (Sweden)

    Benjamin Thumamo Pokam

    2013-01-01

    Full Text Available Among the disadvantages of smear microscopy for detection of tuberculosis cases is its inability to differentiate between Mycobacterium tuberculosis (MTB and non-tuberculous mycobacteria (NTM. This study evaluated two, new immunochromatographic assays – Capilia TB-Neo and SD Bioline – on unheated and heated cultures at 80 °C for 30 min respectively for their ability to discriminate between MTB complex and NTM as compared with the molecular Genotype assay. Mycobacteria used in the study were obtained from smear-positive specimens collected from patients at four major hospitals in Cross River State, Nigeria. Capilia TB-Neo and SD Bioline showed sensitivities of 98.8% and 93.8% respectively and 100% specificity for both assays. Heating the isolates did not significantly impact the test performance. Both tests are recommended for use in rapid differentiation of strains isolated in Nigeria.

  16. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  17. Survey of EEC solid waste arisings and performance of non-destructive assay systems

    International Nuclear Information System (INIS)

    Bremner, W.B.; Adaway, D.W.; Yates, A.

    1992-01-01

    This report covers the work carried out during an one-year contract which surveyed the radioactive solid waste arisings in EEC Member States and also tabulated information on the performance of the non-destructive assay (NDA) system used. The work was jointly carried out with CEA partners at Cadarache and Paris. The tabulated data give information on types, packaging, associated activity, and NDA capability of the utilities or research organisations. Some short comings in NDA capabilities are identified and possible solutions are given

  18. Dopaminergic Immunofluorescence Studies in Kidney Tissue.

    Science.gov (United States)

    Gildea, J J; Van Sciver, R E; McGrath, H E; Kemp, B A; Jose, P A; Carey, R M; Felder, R A

    2017-01-01

    The kidney is a highly integrated system of specialized differentiated cells that are responsible for fluid and electrolyte balance in the body. While much of today's research focuses on isolated nephron segments or cells from nephron segments grown in tissue culture, an often overlooked technique that can provide a unique view of many cell types in the kidney is slice culture. Here, we describe techniques that use freshly excised kidney tissue from rats to perform a variety of experiments shortly after isolating the tissue. By slicing the rat kidney in a "bread loaf" format, multiple studies can be performed on slices from the same tissue in parallel. Cryosectioning and staining of the tissue allow for the evaluation of physiological or biochemical responses in a wide variety of specific nephron segments. The procedures described within this chapter can also be extended to human or mouse kidney tissue.

  19. Immunofluorescence detection of milk protein in meat products

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2015-05-01

    examined, these were selected with regard to the presence of milk protein that was declared by the manufacturer on the packaging. Method validation was performed by comparing the positive results from the investigated method with information on the packaging of the meat product. Milk protein was detected in 84.62 per cent of samples where the manufacturer declared the presence of milk or cheese on the package and additionally in 85.71 per cent of samples where the manufacturer declared the presence of milk protein. The results show that the immunofluorescence method is suitable for the detection of milk protein in meat products.

  20. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2009-01-01

    Each testing and analytical facility performing waste characterization activities for the Waste Isolation Pilot Plant (WIPP) participates in the Performance Demonstration Program (PDP) to comply with the Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC) (DOE/WIPP-02-3122) and the Quality Assurance Program Document (QAPD) (CBFO-94-1012). The PDP serves as a quality control check for data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed to each of the facilities participating in the PDP. The PDP evaluates analyses of simulated headspace gases, constituents of the Resource Conservation and Recovery Act (RCRA), and transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques.

  1. IFDOTMETER: A New Software Application for Automated Immunofluorescence Analysis.

    Science.gov (United States)

    Rodríguez-Arribas, Mario; Pizarro-Estrella, Elisa; Gómez-Sánchez, Rubén; Yakhine-Diop, S M S; Gragera-Hidalgo, Antonio; Cristo, Alejandro; Bravo-San Pedro, Jose M; González-Polo, Rosa A; Fuentes, José M

    2016-04-01

    Most laboratories interested in autophagy use different imaging software for managing and analyzing heterogeneous parameters in immunofluorescence experiments (e.g., LC3-puncta quantification and determination of the number and size of lysosomes). One solution would be software that works on a user's laptop or workstation that can access all image settings and provide quick and easy-to-use analysis of data. Thus, we have designed and implemented an application called IFDOTMETER, which can run on all major operating systems because it has been programmed using JAVA (Sun Microsystems). Briefly, IFDOTMETER software has been created to quantify a variety of biological hallmarks, including mitochondrial morphology and nuclear condensation. The program interface is intuitive and user-friendly, making it useful for users not familiar with computer handling. By setting previously defined parameters, the software can automatically analyze a large number of images without the supervision of the researcher. Once analysis is complete, the results are stored in a spreadsheet. Using software for high-throughput cell image analysis offers researchers the possibility of performing comprehensive and precise analysis of a high number of images in an automated manner, making this routine task easier. © 2015 Society for Laboratory Automation and Screening.

  2. In Situ Immunofluorescent Staining of Autophagy in Muscle Stem Cells

    KAUST Repository

    Castagnetti, Francesco

    2017-06-13

    Increasing evidence points to autophagy as a crucial regulatory process to preserve tissue homeostasis. It is known that autophagy is involved in skeletal muscle development and regeneration, and the autophagic process has been described in several muscular pathologies and agerelated muscle disorders. A recently described block of the autophagic process that correlates with the functional exhaustion of satellite cells during muscle repair supports the notion that active autophagy is coupled with productive muscle regeneration. These data uncover the crucial role of autophagy in satellite cell activation during muscle regeneration in both normal and pathological conditions, such as muscular dystrophies. Here, we provide a protocol to monitor the autophagic process in the adult Muscle Stem Cell (MuSC) compartment during muscle regenerative conditions. This protocol describes the setup methodology to perform in situ immunofluorescence imaging of LC3, an autophagy marker, and MyoD, a myogenic lineage marker, in muscle tissue sections from control and injured mice. The methodology reported allows for monitoring the autophagic process in one specific cell compartment, the MuSC compartment, which plays a central role in orchestrating muscle regeneration.

  3. SRTC Spreadsheet to Determine Relative Percent Difference (RPD) for Duplicate Waste Assay Results and to Perform the RPD Acceptance Test

    International Nuclear Information System (INIS)

    Casella, V.R.

    2002-01-01

    This report documents the calculations and logic used for the Microsoft(R) Excel spreadsheet that is used at the 773-A Solid Waste Assay Facility for evaluating duplicate analyses, and validates that the spreadsheet is performing these functions correctly

  4. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    Science.gov (United States)

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Rackham, Jamie; Weber, Anne-Laure; Chard, Patrick

    2012-01-01

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  6. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Rackham, Jamie [Babcock International Group, Sellafield, Seascale, Cumbria, (United Kingdom); Weber, Anne-Laure [Institut de Radioprotection et de Surete Nucleaire Fontenay-Aux-Roses (France); Chard, Patrick [Canberra, Forss Business and Technology park, Thurso, Caithness (United Kingdom)

    2012-12-15

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  7. Comparison of new immunofluorescence method for detection of soy protein in meat products with immunohistochemical, histochemical, and ELISA methods

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-01-01

    Full Text Available Soy proteins are commonly used in the food industry thanks to their technological properties. However, soy is, along with cow’s milk, eggs, wheat, peanuts, tree nuts, fish, crustaceans, and molluscs, responsible for around 90% of food allergies, and is also one of the foodstuffs that can cause anaphylaxis. The aim of this work was to compare the immunofluorescence method for the detection of soy protein in meat products purchased from the retail market with other microscopic methods (immunohistochemical and histochemical, with the ELISA reference method and with the confirmatory results. Within the research, 127 meat products purchased in the retail network were examined using the immunofluorescence method used for the detection of soy protein. The method was compared to Enzyme-Linked ImmunoSorbent Assay (ELISA, immunohistochemical, and histochemical methods. According to McNemar’s test, non-compliance between the immunofluorescence method and immunohistochemical method was low. In addition, a significant difference between the fluorescence method and ELISA (P P < 0.01 was found. The immunofluorescence method was also compared with confirmatory results. According to McNemar’s test, non-compliance between the immunofluorescence method and confirmatory results was low. The results showed the possibilities of this new method to detect the content of soy protein in meat products.

  8. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    DOE Carlsbad Field Office

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the drummed waste PDP, a simulated waste container consists of a 55-gallon matrix drum emplaced with radioactive standards and fabricated matrix inserts. These PDP sample components are distributed to the participating measurement facilities that have been designated and authorized by the Carlsbad Field Office (CBFO). The NDA Drum PDP materials are stored at these sites under secure conditions to

  9. Immunofluorescence detection of pea protein in meat products.

    Science.gov (United States)

    Petrášová, Michaela; Pospiech, Matej; Tremlová, Bohuslava; Javůrková, Zdeňka

    2016-08-01

    In this study we developed an immunofluorescence method to detect pea protein in meat products. Pea protein has a high nutritional value but in sensitive individuals it may be responsible for causing allergic reactions. We produced model meat products with various additions of pea protein and flour; the detection limit (LOD) of the method for pea flour was 0.5% addition, and for pea protein it was 0.001% addition. The repeatabilities and reproducibilities for samples both positive and negative for pea protein were all 100%. In a blind test with model products and commercial samples, there was no statistically significant difference (p > 0.05) between the declared concentrations of pea protein and flour and the immunofluorescence method results. Sensitivity was 1.06 and specificity was 1.00. These results show that the immunofluorescence method is suitable for the detection of pea protein in meat products.

  10. An interferon-gamma release assay test performs well in routine screening for tuberculosis

    DEFF Research Database (Denmark)

    Vestergaard Danielsen, Allan; Fløe, Andreas; Lillebæk, Troels

    2014-01-01

    Introduction: A positive interferon-gamma release assay (IGRA) is regarded as proof of latent Mycobacterium tuberculosis infection. We conducted an evaluation of the IGRA test “T-SPOT.TB” to test its performance during clinical routine use by analysing the positivity rate and odds, effect of season...... and sensitivity. Material and methods: Data from T-SPOT.TB testing together with age and test indications (anti-tumour necrosis factor alpha (TNFα) candidate, contact investigation or suspicion of tuberculosis (TB)) were combined with mycobac­teria culture results. Results: A total of 1,809 patients were tested....... Conclusive results were achieved for 1,780 patients (98.4%). Among these, 4.6% of anti-TNFα candidates, 19.3% of contacts and 24.4% of TB suspects tested positive. Compared with anti-TNFα candidates, the odds for a positive result were significantly higher for contact investigations (odds ratio (OR), mean...

  11. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    Science.gov (United States)

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  12. Effects of β-glucan polysaccharide revealed by the dominant lethal assay and micronucleus assays, and reproductive performance of male mice exposed to cyclophosphamide

    Directory of Open Access Journals (Sweden)

    Rodrigo Juliano Oliveira

    2014-01-01

    Full Text Available β-glucan is a well-known polysaccharide for its chemopreventive effect. This study aimed to evaluate the chemopreventive ability of β-glucan in somatic and germ cells through the dominant lethal and micronucleus assays, and its influence on the reproductive performance of male mice exposed to cyclophosphamide. The results indicate that β-glucan is capable of preventing changes in DNA in both germ cells and somatic ones. Changes in germ cells were evaluated by the dominant lethal assay and showed damage reduction percentages of 46.46% and 43.79% for the doses of 100 and 150 mg/kg. For the somatic changes, evaluated by micronucleus assay in peripheral blood cells in the first week of treatment, damage reduction percentages from 80.63-116.32% were found. In the fifth and sixth weeks, the percentage ranged from 10.20-52.54% and -0.95-62.35%, respectively. Besides the chemopreventive efficiency it appears that the β-glucan, when combined with cyclophosphamide, is able to improve the reproductive performance of males verified by the significant reduction in rates of post-implantation losses and reabsorption in the mating of nulliparous females with males treated with cyclophosphamide.

  13. Performance Demonstration Program Plan for Nondestructive Assay of Boxed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2001-01-01

    The Performance Demonstration Program (PDP) for nondestructive assay (NDA) consists of a series of tests to evaluate the capability for NDA of transuranic (TRU) waste throughout the Department of Energy (DOE) complex. Each test is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements obtained from NDA systems used to characterize the radiological constituents of TRU waste. The primary documents governing the conduct of the PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC; DOE 1999a) and the Quality Assurance Program Document (QAPD; DOE 1999b). The WAC requires participation in the PDP; the PDP must comply with the QAPD and the WAC. The WAC contains technical and quality requirements for acceptable NDA. This plan implements the general requirements of the QAPD and applicable requirements of the WAC for the NDA PDP for boxed waste assay systems. Measurement facilities demonstrate acceptable performance by the successful testing of simulated waste containers according to the criteria set by this PDP Plan. Comparison among DOE measurement groups and commercial assay services is achieved by comparing the results of measurements on similar simulated waste containers reported by the different measurement facilities. These tests are used as an independent means to assess the performance of measurement groups regarding compliance with established quality assurance objectives (QAO's). Measurement facilities must analyze the simulated waste containers using the same procedures used for normal waste characterization activities. For the boxed waste PDP, a simulated waste container consists of a modified standard waste box (SWB) emplaced with radioactive standards and fabricated matrix inserts. An SWB is a waste box with ends designed specifically to fit the TRUPACT-II shipping container. SWB's will be used to package a substantial volume of the TRU waste for disposal. These PDP sample components

  14. Performance characteristics of SCC radioimmunoassay and clinical significance serum SCC Ag assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, Dong Youn

    1986-01-01

    To evaluate the performance characteristics of SCC RIV and the clinical significance of serum SCC Ag assay in patients with malignancy, serum SCC Ag levels were measured by SCC RIV kit in 40 normal controls and 35 percents with various untreated malignancy, who visited Chonju Presbyterian Medical Center. The results were as follows; 1. The SCC RIA was simple to perform and can be completed in two workday. And the standard curve and reproducibility were both good. 2. The mean serum SCC Ag level in normal controls was 1.64 ± 0.93 ng/mL and normal upper limit of serum SCC Ag was defined as 2.6 ng/mL. 3 out of 40 (7.5%) normal controls showed elevated SCC Ag levels above the normal upper limit. 3. In 35 patients with various untreated malignancy, 18 patients (51.4%) showed elevated serum SCC Ag levels, 59.1% of 22 patients with cervical cancer, 80% of 5 patients with lung cancer, 33% of 3 patients with esophageal cancer, 0% of 2 patients with rectal cancer and 0% of 3 patients with breast cancer showed elevated serum SCC Ag levels. Above results represent that SCC RIV is simple method to perform followed by good standard curve and reproducibility, and may be a useful indicator reflecting diagnostic data of patients with cervical cancer and lung cancer

  15. Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

    International Nuclear Information System (INIS)

    Suhy, Il Kyo; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

    1987-01-01

    To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit (Abott and Daichi). Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 volunteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intraassay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/1 respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU,/l. Mean recovery rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/1 and 2.85-30.8 mU/1 repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function

  16. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    Science.gov (United States)

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX® Colon Cancer Assay

    International Nuclear Information System (INIS)

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-01-01

    The Oncotype DX ® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS) that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log 2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 C T s), gene groups (≤0.05 normalized/aggregate C T s) and RS (≤1.38 RS units). Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery

  18. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX® Colon Cancer Assay

    Directory of Open Access Journals (Sweden)

    Krishnakumar Jayadevi

    2010-12-01

    Full Text Available Abstract Background The Oncotype DX® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT polymerase chain reaction (PCR assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. Results All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 CTs, gene groups (≤0.05 normalized/aggregate CTs and RS (≤1.38 RS units. Conclusions Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery.

  19. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX Colon Cancer Assay.

    Science.gov (United States)

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-12-23

    The Oncotype DX Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS) that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 CTs), gene groups (≤ 0.05 normalized/aggregate CTs) and RS (≤ 1.38 RS units). Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery.

  20. Role of direct immunofluorescence in the diagnosis of glomerulonephritis

    Directory of Open Access Journals (Sweden)

    Archana C Buch

    2015-01-01

    Full Text Available Background: Immunofluorescence microscopy is a vital tool for the diagnosis of glomerular diseases. This study was carried out to study patterns of glomerulonephritis (GN and to record the sensitivity of direct immunofluorescence (DIF in renal lesions. The DIF findings were correlated with clinical and histopathology findings and discrepancies were analyzed. Materials and Methods: The cross-sectional analytical study was conducted during the period July 2011 to July 2013 at a tertiary care Hospital, Department of Pathology. A total of 75 renal biopsies were received for routine and immunofluorescence studies in which histopathology and clinical data were reviewed and analyzed. Results: The sensitivity of DIF was 87.9% and specificity was 70.5%. The maximum number of cases were seen in the age group 41-50 years. The pattern of GN by DIF was minimal change disease (MCD in 24%, IgA nephropathy in 13%, focal segmental glomerulosclerosis in 9% and membranoproliferative glomerulonephritis in 8% of the cases. Twelve histopathologically proven cases of GN were negative on DIF. One case of MCD on histopathology was diagnosed as IgM nephropathy based on DIF. Conclusion: Direct immunofluorescence forms an important diagnostic tool in reaching the exact diagnosis in various types of GN presenting with overlapping clinical and histomorphological features.

  1. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  2. Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

    International Nuclear Information System (INIS)

    2005-01-01

    The Performance Demonstration Program (PDP) for Nondestructive Assay (NDA) is a test program designed to yield data on measurement system capability to characterize drummed transuranic (TRU) waste generated throughout the Department of Energy (DOE) complex. The tests are conducted periodically and provide a mechanism for the independent and objective assessment of NDA system performance and capability relative to the radiological characterization objectives and criteria of the Office of Characterization and Transportation (OCT). The primary documents requiring an NDA PDP are the Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC), which requires annual characterization facility participation in the PDP, and the Quality Assurance Program Document (QAPD). This NDA PDP implements the general requirements of the QAPD and applicable requirements of the WAC. Measurement facilities must demonstrate acceptable radiological characterization performance through measurement of test samples comprised of pre-specified PDP matrix drum/radioactive source configurations. Measurement facilities are required to analyze the NDA PDP drum samples using the same procedures approved and implemented for routine operational waste characterization activities. The test samples provide an independent means to assess NDA measurement system performance and compliance per criteria delineated in the NDA PDP Plan. General inter-comparison of NDA measurement system performance among DOE measurement facilities and commercial NDA services can also be evaluated using measurement results on similar NDA PDP test samples. A PDP test sample consists of a 55-gallon matrix drum containing a waste matrix type representative of a particular category of the DOE waste inventory and nuclear material standards of known radionuclide and isotopic composition typical of DOE radioactive material. The PDP sample components are made available to participating measurement facilities as designated by the

  3. Analytical and clinical performance of thyroglobulin autoantibody assays in thyroid cancer follow-up.

    Science.gov (United States)

    Katrangi, Waddah; Grebe, Stephan K G; Algeciras-Schimnich, Alicia

    2017-10-26

    While thyroglobulin autoantibodies (TgAb) can result in false low serum thyroglobulin (Tg) immunoassay (IA) measurements, they might also be indicators of disease persistence/recurrence. Hence, accurate TgAb measurement, in addition to Tg quantification, is crucial for thyroid cancer monitoring. We compared the analytical and clinical performance of four commonly used TgAb IAs. We measured Tg by mass spectrometry (Tg-MS) and by four pairs of Tg and TgAb IAs (Beckman, Roche, Siemens, Thermo) in 576 samples. Limit of quantitation (LOQ) and manufacturers' upper reference interval cut-off (URI) were used for comparisons. Clinical performance was assessed by receiving operator characteristics (ROC) curve analysis. Quantitative and qualitative agreement between TgAb-IAs was moderate with R2 of 0.20-0.70 and κ from 0.41-0.66 using LOQ and 0.47-0.71 using URI. In samples with TgAb interference, detection rates of TgAb were similar using LOQ and URI for Beckman, Siemens, and Thermo, but much lower for the Roche TgAb-IA when the URI was used. In TgAb positive cases, the ROC areas under the curve (AUC) for the TgAb-IAs were 0.59 (Beckman), 0.62 (Siemens), 0.59 (Roche), and 0.59 (Thermo), similar to ROC AUCs achieved with Tg. Combining Tg and TgAb measurements improved the ROC AUCs compared to Tg or TgAb alone. TgAb-IAs show significant qualitative and quantitative differences. For 2 of the 4 TgAb-IAs, using the LOQ improves the detection of interfering TgAbs. All assays showed suboptimal clinical performance when used as surrogate markers of disease, with modest improvements when Tg and TgAb were combined.

  4. Analytical evaluation of Lumipulse® BRAHMS PCT CLEIA assay and clinical performances in an unselected population as compared with central lab PCT assay.

    Science.gov (United States)

    Dupuy, Anne Marie; Né, Maxence; Bargnoux, Anne Sophie; Badiou, Stéphanie; Cristol, Jean Paul

    2017-03-01

    We report the analytical performances of the Lumipulse®G BRAHMS PCT assay (Fujirebio, Courteboeuf, France) and the concordance with BRAHMS PCT Kryptor CompactPlus© results from central laboratory. Lumipulse®G BRAHMS PCT immunoassay on Lumipulse®G600II instrument is a chemiluminescence enzyme immunoassay (CLEIA). Analytical performances included imprecision study, linearity, limit of detection and comparison study on 138 plasma specimen on Lumipulse®G600II vs plasma on Kryptor CompactPlus©. The intra and inter assay imprecision of Lumipulse®G BRAHMS PCT was between 2 and 5%. The LoD in our condition was 0.0029ng/mL in accordance with the LoD provided by the manufacturer (0.0048ng/mL). The linear equation of linearity was y=1,001×-0,052 with r 2 =0.99, with a mean recovery (SD) percentage of 1.8% (8%). Correlation studies showed a good correlation (r=0.99) between plasma on Kryptor and Lumipulse, with a bias of 0.02 in the range from 0.12 to 1ng/mL. The new adaptation developed from Fujirebio on quantification of PCT with CLEIA technology from monoclonal antibodies from ThermoFisher appears to be acceptable for clinical use. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.

    Science.gov (United States)

    Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew

    2016-06-01

    The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.

  6. High-performance liquid chromatographic assay for genistein in biological fluids.

    Science.gov (United States)

    Supko, J G; Phillips, L R

    1995-04-07

    A specific, sensitive and technically convenient HPLC method for assaying genistein in biological fluids has been developed. The compound and 4-hydroxybenzophenone, added as an internal standard, were efficiently isolated from both plasma and urine by extraction with tert-butyl methyl ether. Following evaporation of the organic solvent, the extract was reconstituted with methanol-0.05 M ammonium acetate buffer, pH 4.7 (30:70, v/v), and loaded onto a 4 microns Nova-Pak C8 column (15 cm x 3.9 mm I.D.). Chromatography was performed at ambient temperature using a mobile phase of acetonitrile-0.05 M ammonium formate buffer, pH 4.0 (27:73, v/v), at a flow-rate of 1.0 ml/min, with UV detection at 260 nm. Mean values of the tR for the drug and internal standard, determined from chromatograms of the 1 microgram/ml plasma standard during a 6 month period, were 8.27 +/- 0.55 and 11.92 +/- 0.71 min, respectively (S.D., n = 29). With a sample volume of 50 microliters, the lowest concentration of genistein included in the plasma standard curve, 0.020 microgram/ml, was quantified with a 10.7% R.S.D. over a 5 month period. Plasma standards having concentrations of 0.050 to 1.02 micrograms/ml exhibited R.S.D. values ranging from 2.3 to 6.1%. The drug was quantified in urine with similar reproducibility. The sensitivity of the assay was adequate for characterizing the plasma pharmacokinetics of genistein in the mouse and dog. However, a 10-fold improvement in sensitivity was afforded by increasing the sample size to 250 microliters, without otherwise modifying the method. Thus, this procedure may prove suitable for determining plasma and urine levels of genistein in humans consuming dietary isoflavonoids in a much more convenient manner than permitted by existing methodology.

  7. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    Science.gov (United States)

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  8. Performance values for non destructive assay (NDA) techniques applied to safeguards: the 2002 evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Guardini, S.

    2003-01-01

    The first evaluation of NDA performance values undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques (WGNDA) was published in 1993. Almost 10 years later the Working Group decided to review those values, to report about improvements and to issue new performance values for techniques which were not applied in the early nineties, or were at that time only emerging. Non-Destructive Assay techniques have become more and more important in recent years, and they are used to a large extent in nuclear material accountancy and control both by operators and control authorities. As a consequence, the performance evaluation for NDA techniques is of particular relevance to safeguards authorities in optimising Safeguards operations and reducing costs. Performance values are important also for NMAC regulators, to define detection levels, limits for anomalies, goal quantities and to negotiate basic audit rules. This paper presents the latest evaluation of ESARDA Performance Values (EPVs) for the most common NDA techniques currently used for the assay of nuclear materials for Safeguards purposes. The main topics covered by the document are: techniques for plutonium bearing materials: PuO 2 and MOX; techniques for U-bearing materials; techniques for U and Pu in liquid form; techniques for spent fuel assay. This issue of the performance values is the result of specific international round robin exercises, field measurements and ad hoc experiments, evaluated and discussed in the ESARDA NDA Working Group. (author)

  9. Assay of fluconazole by high-performance liquid chromatography with a mixed-phase column.

    OpenAIRE

    Wallace, J E; Harris, S C; Gallegos, J; Foulds, G; Chen, T J; Rinaldi, M G

    1992-01-01

    A mixed-phase liquid chromatographic column was used to assay fluconazole in plasma, serum, and cerebrospinal fluid. The assay was linear from 0.2 to 20 micrograms/ml, with an average coefficient of variation of less than 5%. The partitioning of the drug between serum and cerebrospinal fluid was determined for 34 patients. The method was demonstrated to be suitable for both pharmacokinetic studies and monitoring of patients receiving treatment with this antifungal agent.

  10. Clinical evaluation of a helicase-dependant amplification (HDA)-based commercial assay for the simultaneous detection of HSV-1 and HSV-2.

    Science.gov (United States)

    Teo, Jeanette W P; Chiang, Donald; Jureen, Roland; Lin, Raymond T P

    2015-11-01

    In this study, we evaluate the performance of a commercial assay, the AmpliVue HSV 1+2 Assay (Quidel), which employs HDA for the detection of both HSV-1 and HSV-2. The assay was tested on 307 clinical specimens (genital, oral, and dermal). When compared to shell vial virus culture and immunofluorescence typing of HSV, the positive percent agreement and negative percent agreement values were 98.2% and 90.9%, respectively. Excellent assay performance was demonstrated. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Directory of Open Access Journals (Sweden)

    Jozo Ćorić

    2015-04-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the ß-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens and Cobas 501 (Roche analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision.

  12. Performance evaluation of the Cobas TaqMan MTB assay on respiratory specimens according to clinical application

    Directory of Open Access Journals (Sweden)

    Jong Eun Park

    2017-11-01

    Full Text Available Objective: To evaluate the performance of the Cobas TaqMan MTB assay (Cobas assay with respect to its clinical application. Methods: This was a retrospective analysis of 1154 results from 1034 patients for whom mycobacterial cultures and the Cobas assay were performed simultaneously. Based on the patient medical records, two categories of clinical application were defined: (1 the diagnosis of patients with a high probability of pulmonary tuberculosis according to clinical and radiological features (n = 128, and (2 the exclusion of tuberculosis in clinically indeterminate patients (n = 1026. Standard culture was used as the reference method. Results: The sensitivity of the Cobas assay for the detection of Mycobacterium tuberculosis was 70.4% (95% confidence interval (CI 49.7–85.5% for category 1, but only 25.0% (95% CI 4.5–64.4% for category 2. The specificity was ≥95.0% for both categories. The positive predictive value was 79.2% (95% CI 57.3–92.1% for category 1 and 33.3% (95% CI 6.0–75.9% for category 2, while the negative predictive value was 92.3% (95% CI 85.0–96.4% for category 1 and 99.4% (95% CI 98.7–99.8% for category 2. Conclusions: The results of this study indicate that Cobas assay results must be interpreted carefully according to the clinical purpose of the assay. Keywords: Mycobacterium tuberculosis, Pulmonary tuberculosis, Cobas TaqMan MTB assay, Korea

  13. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts

    NARCIS (Netherlands)

    de Jong, C.F.; Derks, R.J.E.; Bruyneel, B.; Niessen, W.M.A.; Irth, H.

    2006-01-01

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the

  14. Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum.

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona; Sambri, Vittorio

    2015-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  15. Performance evaluation of FlowCytomix assays to quantify cytokines in patients with rheumatoid arthritis

    Science.gov (United States)

    Wang, Xuefeng; Dong, Liyang; Liang, Yong; Ni, Hongchang; Tang, Jun; Xu, Chengcheng; Zhou, Yuepeng; Su, Yuting; Wang, Jun; Chen, Deyu; Mao, Chaoming

    2015-01-01

    Objectives: To compare the cytokine profile in RA patients and healthy control by using two methods-FlowCytomix assay and traditional ELISA. Methods: Cytokine levels were evaluated by FlowCytomix assay and ELISA in serum and supernatants of peripheral blood mononuclear cells (PBMC) cultures with and without stimulation by phytohaemagglutinin (PHA). Results: The levels of IL-6, IL-1β, and TNF-α were significantly higher in sera of RA patients than those of healthy controls. The levels of IL-22, IL-6, IL-1β, TNF-α, and IL-10 were higher in unstimulated PBMC culture supernatant of RA patients than those of healthy controls. PHA stimulation significantly increased the production of proinflammatory cytokines from PBMC with RA patients. Compared with detectable cytokine levels in sera, cytokine concentration in the supernatant of PBMCs was remarkably higher. FlowCytomix and ELISA showed significant correlation in detecting cytokines. However, the FlowCytomix assay detected more cytokines than ELISA. Conclusion: The supernatant of PBMCs provide a fine condition for the study of cytokine production because of the lack of interference factors in sera. The FlowCytomix assay is more sensitive than ELISA in detecting cytokines from RA patients. Multiple cytokine signatures using FlowCytomix assay may represent a more realistic approach in the future of personalized medicine in RA. PMID:26629129

  16. Performance Evaluation of the Elecsys Syphilis Assay for the Detection of Total Antibodies to Treponema pallidum

    Science.gov (United States)

    Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona

    2014-01-01

    Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799

  17. New high-performance liquid chromatography assay for glycosyltransferases based on derivatization with anthranilic acid and fluorescence detection.

    Science.gov (United States)

    Anumula, Kalyan Rao

    2012-07-01

    Assays were developed using the unique labeling chemistry of 2-aminobenzoic acid (2AA; anthranilic acid, AA) for measuring activities of both β1-4 galactosyltransferase (GalT-1) and α2-6 sialyltransferase (ST-6) by high-performance liquid chromatography (HPLC) with fluorescence detection (Anumula KR. 2006. Advances in fluorescence derivatization methods for high-performance liquid chromatographic analysis of glycoprotein carbohydrates. Anal Biochem. 350:1-23). N-Acetylglucosamine (GlcNAc) and N-acetyllactosamine were used as acceptors and uridine diphosphate (UDP)-galactose and cytidine monophosphate (CMP)-N-acetylneuraminic acid (NANA) as donors for GalT-1 and ST-6, respectively. Enzymatic products were labeled in situ with AA and were separated from the substrates on TSKgel Amide 80 column using normal-phase conditions. Enzyme units were determined from the peak areas by comparison with the concomitantly derivatized standards Gal-β1-4GlcNAc and NANA-α2-6 Gal-β1-4GlcNAc. Linearity (time and enzyme concentration), precision (intra- and interassay) and reproducibility for the assays were established. The assays were found to be useful in monitoring the enzyme activities during isolation and purification. The assays were highly sensitive and performed equal to or better than the traditional radioactive sugar-based measurements. The assay format can also be used for measuring the activity of other transferases, provided that the carbohydrate acceptors contain a reducing end for labeling. An assay for glycoprotein acceptors was developed using IgG. A short HPLC profiling method was developed for the separation of IgG glycans (biantennary G0, G1, G2, mono- and disialylated), which facilitated the determination of GalT-1 and ST-6 activities in a rapid manner. Furthermore, this profiling method should prove useful for monitoring the changes in IgG glycans in clinical settings.

  18. Semi-automated relative quantification of cell culture contamination with mycoplasma by Photoshop-based image analysis on immunofluorescence preparations.

    Science.gov (United States)

    Kumar, Ashok; Yerneni, Lakshmana K

    2009-01-01

    Mycoplasma contamination in cell culture is a serious setback for the cell-culturist. The experiments undertaken using contaminated cell cultures are known to yield unreliable or false results due to various morphological, biochemical and genetic effects. Earlier surveys revealed incidences of mycoplasma contamination in cell cultures to range from 15 to 80%. Out of a vast array of methods for detecting mycoplasma in cell culture, the cytological methods directly demonstrate the contaminating organism present in association with the cultured cells. In this investigation, we report the adoption of a cytological immunofluorescence assay (IFA), in an attempt to obtain a semi-automated relative quantification of contamination by employing the user-friendly Photoshop-based image analysis. The study performed on 77 cell cultures randomly collected from various laboratories revealed mycoplasma contamination in 18 cell cultures simultaneously by IFA and Hoechst DNA fluorochrome staining methods. It was observed that the Photoshop-based image analysis on IFA stained slides was very valuable as a sensitive tool in providing quantitative assessment on the extent of contamination both per se and in comparison to cellularity of cell cultures. The technique could be useful in estimating the efficacy of anti-mycoplasma agents during decontaminating measures.

  19. Detection of Bim and Puma in mouse hair follicles using immunofluorescence and TUNEL assay double staining

    Czech Academy of Sciences Publication Activity Database

    Veselá, Barbora; Matalová, Eva

    2015-01-01

    Roč. 90, č. 8 (2015), s. 587-593 ISSN 1052-0295 Grant - others:GA ČR(CZ) GAP502/12/1285 Program:GA Institutional support: RVO:67985904 Keywords : apoptosis * Bim * development Subject RIV: ED - Physiology Impact factor: 1.078, year: 2015

  20. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  1. Performance assessment of self-interrogation neutron resonance densitometry for spent nuclear fuel assay

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei, E-mail: huj1@ornl.gov [Reactor and Nuclear Systems Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, PO Box 2008, MS-6172, Oak Ridge, TN 37831-6172 (United States); Tobin, Stephen J.; LaFleur, Adrienne M.; Menlove, Howard O.; Swinhoe, Martyn T. [Nuclear Engineering and Nonproliferation Division, Los Alamos National Laboratory (United States)

    2013-11-21

    Self-Interrogation Neutron Resonance Densitometry (SINRD) is one of several nondestructive assay (NDA) techniques being integrated into systems to measure spent fuel as part of the Next Generation Safeguards Initiative (NGSI) Spent Fuel Project. The NGSI Spent Fuel Project is sponsored by the US Department of Energy's National Nuclear Security Administration to measure plutonium in, and detect diversion of fuel pins from, spent nuclear fuel assemblies. SINRD shows promising capability in determining the {sup 239}Pu and {sup 235}U content in spent fuel. SINRD is a relatively low-cost and lightweight instrument, and it is easy to implement in the field. The technique makes use of the passive neutron source existing in a spent fuel assembly, and it uses ratios between the count rates collected in fission chambers that are covered with different absorbing materials. These ratios are correlated to key attributes of the spent fuel assembly, such as the total mass of {sup 239}Pu and {sup 235}U. Using count rate ratios instead of absolute count rates makes SINRD less vulnerable to systematic uncertainties. Building upon the previous research, this work focuses on the underlying physics of the SINRD technique: quantifying the individual impacts on the count rate ratios of a few important nuclides using the perturbation method; examining new correlations between count rate ratio and mass quantities based on the results of the perturbation study; quantifying the impacts on the energy windows of the filtering materials that cover the fission chambers by tallying the neutron spectra before and after the neutrons go through the filters; and identifying the most important nuclides that cause cooling-time variations in the count rate ratios. The results of these studies show that {sup 235}U content has a major impact on the SINRD signal in addition to the {sup 239}Pu content. Plutonium-241 and {sup 241}Am are the two main nuclides responsible for the variation in the count

  2. Radiochemical assay for determination of dihydropyrimidinase activity using reversed-phase high-performance liquid chromatography

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; van Lenthe, H.; van Gennip, A. H.

    1999-01-01

    A radiochemical assay was developed to measure the activity of dihydropyrimidinase (DHP) in human liver homogenates. The method is based on the separation of radiolabeled dihydrouracil from N-carbamyl-beta-alanine by HPLC with on-line detection of radioactivity combined with detection of 14CO2 by

  3. Analytical performances of a new enzymatic assay for hemoglobin A1c.

    Science.gov (United States)

    Jaisson, Stéphane; Desmons, Aurore; Renard, Benoît; Chevelle, Benjamin; Leroy, Nathalie; Gillery, Philippe

    2014-07-01

    HbA1c is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA1c by a fructosyl dipeptide oxidase using Architect analyzers. Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA1c measurement have been evaluated. Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA1c [Architect, mmol/mol]=0.986×HbA1c [Variant II, mmol/mol]+0.713 (r=0.998, n=109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA1c assays (i.e. labile HbA1c, carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA1c quantification by this method. This new enzymatic assay proved to be a robust and reliable method for HbA1c measurement suitable for routine practice in clinical chemistry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A sensitive high performance liquid chromatography assay for the quantification of doxorubicin associated with DNA in tumor and tissues.

    Science.gov (United States)

    Lucas, Andrew T; O'Neal, Sara K; Santos, Charlene M; White, Taylor F; Zamboni, William C

    2016-02-05

    Doxorubicin, a widely used anticancer agent, exhibits antitumor activity against a wide variety of malignancies. The drug exerts its cytotoxic effects by binding to and intercalating within the DNA of tumor and tissue cells. However, current assays are unable to accurately determine the concentration of the intracellular active form of doxorubicin. Thus, the development of a sample processing method and a high-performance liquid chromatography (HPLC) methodology was performed in order to quantify doxorubicin that is associated with DNA in tumors and tissues, which provided an intracellular cytotoxic measure of doxorubicin exposure after administration of small molecule and nanoparticle formulations of doxorubicin. The assay uses daunorubicin as an internal standard; liquid-liquid phase extraction to isolate drug associated with DNA; a Shimadzu HPLC with fluorescence detection equipped with a Phenomenex Luna C18 (2μm, 2.0×100mm) analytical column and a gradient mobile phase of 0.1% formic acid in water or acetonitrile for separation and quantification. The assay has a lower limit of detection (LLOQ) of 10ng/mL and is shown to be linear up to 3000ng/mL. The intra- and inter-day precision of the assay expressed as a coefficient of variation (CV%) ranged from 4.01 to 8.81%. Furthermore, the suitability of this assay for measuring doxorubicin associated with DNA in vivo was demonstrated by using it to quantify the doxorubicin concentration within tumor samples from SKOV3 and HEC1A mice obtained 72h after administration of PEGylated liposomal doxorubicin (Doxil(®); PLD) at 6mg/kg IV x 1. This HPLC assay allows for sensitive intracellular quantification of doxorubicin and will be an important tool for future studies evaluating intracellular pharmacokinetics of doxorubicin and various nanoparticle formulations of doxorubicin. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  6. Quantitative Immunofluorescence Analysis of Nucleolus-Associated Chromatin.

    Science.gov (United States)

    Dillinger, Stefan; Németh, Attila

    2016-01-01

    The nuclear distribution of eu- and heterochromatin is nonrandom, heterogeneous, and dynamic, which is mirrored by specific spatiotemporal arrangements of histone posttranslational modifications (PTMs). Here we describe a semiautomated method for the analysis of histone PTM localization patterns within the mammalian nucleus using confocal laser scanning microscope images of fixed, immunofluorescence stained cells as data source. The ImageJ-based process includes the segmentation of the nucleus, furthermore measurements of total fluorescence intensities, the heterogeneity of the staining, and the frequency of the brightest pixels in the region of interest (ROI). In the presented image analysis pipeline, the perinucleolar chromatin is selected as primary ROI, and the nuclear periphery as secondary ROI.

  7. [Laboratory diagnosis of genital herpes--direct immunofluorescence method].

    Science.gov (United States)

    Majewska, Anna; Romejko-Wolniewicz, Ewa; Zareba-Szczudlik, Julia; Kilijańczyk, Marek; Gajewska, Małgorzata; Młynarczyk, Grazyna

    2013-07-01

    Aim of the study was to determine clinical usefulness of direct immunofluorescence method in the laboratory diagnosis of genital herpes in women. Overall 187 anogenital swabs were collected from 120 women. Using a dacron-tipped applicator 83 swabs were collected from women suspected of genital herpes and 104 from patients with no signs of genital infection. All samples were tested using cell culture (Vero cell line) and then direct immunofluorescence method (DIF) for the identification of antigens of herpes simplex viruses: HSV-1 and HSV-2. Characteristic cytopathic effect (CPE), indicative of alphaherpesvirus infection, was observed in 43.4% of cultures with clinical specimens collected from women with suspected genital herpes and in 29.8% of cultures of clinical specimens taken from patients with no clinical symptoms of genital herpes. Herpes simplex viruses were determined in 73 samples by direct immunofluorescence method after amplification of the virus in cell culture. The DIF test confirmed the diagnosis based on the microscopic CPE observation in 85%. In 15% of samples (taken from pregnant women without clinical signs of infection) we reported positive immunofluorescence in the absence of CPE. The frequency of antigen detection was statistically significantly higher in samples that were positive by culture study (chi-square test with Yates's correction, p genital herpes in swabs taken from the vestibule of the vagina and the vulva. However, there was no statistically significant difference in the frequency of detection of Herpes Simplex Virus antigens in specimens from different parts of the genital tract in both groups of women (chi-square test, p > 0.05). In our study HHV-1 was the main causative agent of genital herpes. The growing worldwide prevalence of genital herpes, challenges with the clinical diagnosis, and availability of effective antiviral therapy are the main reasons for a growing interest in rapid, proper laboratory diagnosis of infected

  8. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    Science.gov (United States)

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; Kleman, Marika; Kulkarni, Medha; Grufman, Per; Nygren, Malin; Kwiatkowski, Robert; Baron, Ellen Jo; Tenover, Fred; Denison, Blake; Higuchi, Russell; Van Atta, Reuel; Beer, Neil Reginald; Carrillo, Alda Celena; Naraghi-Arani, Pejman; Mire, Chad E.; Ranadheera, Charlene; Grolla, Allen; Lagerqvist, Nina; Persing, David H.

    2015-01-01

    Background The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Methods and Findings This study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. Conclusion In summary, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection

  9. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    Science.gov (United States)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  10. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    International Nuclear Information System (INIS)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo

    2014-01-01

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The 3 H and 125 I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step

  11. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    Energy Technology Data Exchange (ETDEWEB)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The {sup 3}H and {sup 125}I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step.

  12. On performance experience and measurements with Ningyo Waste Assay System (NWAS). 3

    International Nuclear Information System (INIS)

    Zaima, Naoki; Nakashima, Shin'ichi; Nakatsuka, Yoshiaki; Kado, Kazumi; Fujiki, Naoki

    2014-03-01

    A uranium mass assay system, NWAS (Ningyo Waste Assay System), for 200-litter wastes drums applied by NDA method was developed and accumulated the data of the actual uranium bearing wastes drums. The system consists of the 16 pieces of Helium-3 proportional counters for neutron detection generated from U-234(α,n) reaction or U-238 spontaneous fissions with polyethylene moderation and a Germanium solid state detector (Ge-SSD) for gamma ray detection as to determine uranium enrichment. In previous report, some measurement experiences had been introduced briefly. After that the measurements campaigns against the actual wastes drums stored in URCP had been carried out successfully, the uranium determination data of 850 drums had been accumulated approximately. Those characteristics were rich in variety including various kinds of matrices, uranium chemical compositions and range of uranium mass and so on. These works have contributed the decrease of the MUF in URCP, for which was the first purpose of introduction of NWAS. On the other hand several considerable problems on the system or methodology had been revealed technically or analytically through the measurements experiences. Such experiences are to be described precisely, in addition newly gained knowledge will be marshaled. Furthermore as the next improvement plans, the active neutrons assay for uranium bearing wastes drums are now progressing. The results of complications will lead us to the progressive next steps. (author)

  13. Diagnostic significance of colloid body deposition in direct immunofluorescence

    Directory of Open Access Journals (Sweden)

    Chularojanamontri Leena

    2010-01-01

    Full Text Available Background: Colloid bodies (CB in direct immunofluorescence (DIF studies are usually found in interface dermatitis. Furthermore, CB can be found in various skin diseases and even in normal skin. Aim: To evaluate the diagnostic value of CB deposits in DIF studies. Methods: From 1996-2007, data from 502 patients where DIF studies showed immunoreactants at CB were enrolled. The definite diagnoses of these patients were based on clinical, histopathological and immunofluorescent findings. The results of DIF studies were analyzed. Results: Immunoreactants at CB were detected in 44.4%, 43.8%, 4.2%, 3.8%, and 2.2% of interface dermatitis, vasculitis, autoimmune vesiculobullous disease, panniculitis, and scleroderma/morphea, respectively. The most common immunoreactant deposit of all diseases was Immunoglobulin M (IgM. Brighter intensity and higher quantity of CB was detected frequently in the group with interface dermatitis. Conclusions: Immunoreactant deposits at CB alone can be found in various diseases but a strong intensity and high quantity favor the diagnosis of interface dermatitis. CB plus dermoepidermal junction (DEJ deposits are more common in interface dermatitis than any other disease. Between lichen planus (LP and discoid lupus erythematosus (DLE, CB alone is more common in LP; whereas, CB plus DEJ and superficial blood vessel (SBV is more common in DLE. The most common pattern in both diseases is CB plus DEJ. The quantity and intensity of CB in LP is higher than in DLE.

  14. The influence of uncertainties of measurements in laboratory performance evaluation using an intercomparison program of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Elizabeth Couto Machado Vianna, Maria; Eduardo de Oliveira, Antonio; Cristina de Melo Ferreira, Ana; Julia Camara da Silva Braganca, Maura; Faria Clain, Almir

    2006-01-01

    To show the influence of measurement uncertainties in performance evaluation of laboratories, data from 42 comparison runs were evaluated using two statistical criteria. The normalized standard deviation, D, used by US EPA, that mainly takes into account the accuracy, and the normalized deviation, E, that includes the individual laboratory uncertainty used for performance evaluation in the key-comparisons by BIPM. The results show that data evaluated by the different criteria give a significant deviation of laboratory performance in each radionuclide assay when we analyse a large quantity of data

  15. Evaluation of hemoglobin A1c measurement from filter paper using high-performance liquid chromatography and immunoturbidimetric assay.

    Science.gov (United States)

    Wu, Yonghua; Yang, Xu; Wang, Haining; Li, Zhenrong; Wang, Tiancheng

    2017-04-01

    Glycated hemoglobin (HbA 1c ) measurement from whole blood (WB) samples is inconvenient for epidemic surveillance and self-monitoring of glycemic level. We evaluated HbA 1c measurement from WB blotted on filter paper (FP), which can be easily transported to central laboratories, with high-performance liquid chromatography (HPLC) and immunoturbidimetric assay (ITA). WB was applied to Whatman filter paper. By using HPLC and WB samples as reference methods, these FP samples were evaluated on HPLC and ITA. Inter- and intra-assay variation, WB vs. FP agreement and sample stability at 20-25 °C and -70 °C were assessed by statistical analysis. Results showed that the coefficient of variation (CV, %) of FP samples for HPLC and ITA were 0.44-1.02% and 1.47-2.72%, respectively (intra-assay); 2.13-3.56% and 3.21-4.82%, respectively (inter-assay). The correlation of WB HPLC with FP analyzed using HPLC and ITA are both significant (p < 0.001). Sample stability showed that FP method up to 5 days at 20-25 °C and 5 weeks at -70 °C is accurate and reproducible. In conclusion, FP samples analyzed by HPLC and ITA can both provide an alternative to WB for HbA 1c measurement, supporting the use of FP method in epidemic surveillance and healthcare units.

  16. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    Science.gov (United States)

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  17. An easy-to-perform photometric assay for methyltransferase activity measurements.

    Science.gov (United States)

    Schäberle, Till F; Siba, Christian; Höver, Thomas; König, Gabriele M

    2013-01-01

    Methyltransferases (MTs) catalyze the transfer of a methyl group from S-adenosylmethionine (SAM) to a suitable substrate. Such methylations are important modifications in secondary metabolisms, especially on natural products produced by polyketide synthases and nonribosomal peptide synthetases, many of which are of special interest due to their prominent pharmacological activities (e.g., lovastatin, cyclosporin). To gain basic biochemical knowledge on the methylation process, it is of immense relevance to simplify methods concerning experimental problems caused by a large variety in substrates. Here, we present a photometric method to analyze MT activity by measuring SAM consumption in a coupled enzyme assay. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Performance of PCR-reverse blot hybridization assay for detection of rifampicin-resistant Mycobacterium leprae.

    Science.gov (United States)

    Wang, Hye-young; Kim, Hyunjung; Kim, Yeun; Bang, Hyeeun; Kim, Jong-Pill; Hwang, Joo Hwan; Cho, Sang-Nae; Kim, Tae Ue; Lee, Hyeyoung

    2015-10-01

    Drug resistance in Mycobacterium leprae is a significant problem in countries where leprosy is endemic. A sensitive, specific, and high-throughput reverse blot hybridization assay (REBA) for the detection of genotypic resistance to rifampicin (RIF) was designed and evaluated. It has been shown that resistance to RIF in M. leprae involves mutations in the rpoB gene encoding the -subunit of the RNA polymerase. The PCR-REBA simultaneously detects both 6 wild-type regions and 5 different mutations (507 AGC, 513 GTG, 516 TAT, 531 ATG, and 531 TTC) including the most prevalent mutations at positions 507 and 531. Thirty-one clinical isolates provided by Korea Institute of Hansen-s Disease were analyzed by PCR-REBA with RIF resistance of rpoB gene. As a result, missense mutations at codons 507 AGC and 531 ATG with 2-nucleotide substitutions were found in one sample, and a missense mutation at codon 516 TAT and ΔWT6 (deletion of 530-534) was found in another sample. These cases were confirmed by DNA sequence analysis. This rapid, simple, and highly sensitive assay provides a practical alternative to sequencing for genotypic evaluation of RIF resistance in M. leprae.

  19. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Directory of Open Access Journals (Sweden)

    Gilberto A Santiago

    Full Text Available Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV. There are four genetically distinct DENVs (DENV-1-4 that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  20. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Science.gov (United States)

    Santiago, Gilberto A; Vergne, Edgardo; Quiles, Yashira; Cosme, Joan; Vazquez, Jesus; Medina, Juan F; Medina, Freddy; Colón, Candimar; Margolis, Harold; Muñoz-Jordán, Jorge L

    2013-01-01

    Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV). There are four genetically distinct DENVs (DENV-1-4) that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA) for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  1. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  2. PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.

    Science.gov (United States)

    Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J

    2018-05-09

    The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.

  3. Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture.

    Science.gov (United States)

    Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka

    2015-05-01

    Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.

  4. Immunofluorescence in multiple tissues utilizing serum from a patient affected by systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Piotr Brzezinski

    2012-01-01

    Full Text Available Introduction: Lupus erythematosus is a chronic, inflammatory autoimmune disease that can affect multiple organs. Lupus can affect many parts of the body, especially in systemic lupus erythematosus (SLE; affected tissues may include the joints, skin, kidneys, heart, lungs, blood vessels, and brain. Case report: A 46-year-old female presented with pruritus, photosensitivity and edema of the cheeks of about 2 years duration, and was evaluated by a dermatologist. On examination, multiple telangiectasias were present on the cheeks, with erythema, edema and a malar rash observed. A review of systems documented breathing difficulty and pleuitic pain, joint pain and joint edema, photosensitivity, cardiac dysrhythmia, and periodic pain in the back close to the kidneys. Methods: Skin biopsies for hematoxylin and eosin testing, as well for direct and indirect immunofluorescence were performed, in addition to multiple diagnostic blood tests, chest radiography and directed immunologic testing. Results: The blood testing showed elevated C-reactive protein. Direct and indirect immunofluorescence testing utilizing monkey esophagus, mouse and pig heart and kidney, normal human eyelid skin and veal brain demonstrated strong reactivity to several components of smooth muscle, nerves, blood vessels, skin basement membrane zone and sweat gland ducts and skin meibomian glands. Anti-endomysium antibodies were detected as well as others, especially using FITC conjugated Complement/C1q, FITC conjugated anti-human immunoglobulin IgG and FITC conjugated anti-human fibrinogen. Conclusions: We conclude that both direct and indirect immunofluorescence using several substrates can unveil previously undocumented autoantibodies in multiple organs in lupus erythematosus, and that these findings could be utilized to complement existing diagnostic testing for this disorder.

  5. Original Approach for Automated Quantification of Antinuclear Autoantibodies by Indirect Immunofluorescence

    Directory of Open Access Journals (Sweden)

    Daniel Bertin

    2013-01-01

    Full Text Available Introduction. Indirect immunofluorescence (IIF is the gold standard method for the detection of antinuclear antibodies (ANA which are essential markers for the diagnosis of systemic autoimmune rheumatic diseases. For the discrimination of positive and negative samples, we propose here an original approach named Immunofluorescence for Computed Antinuclear antibody Rational Evaluation (ICARE based on the calculation of a fluorescence index (FI. Methods. We made comparison between FI and visual evaluations on 237 consecutive samples and on a cohort of 25 patients with SLE. Results. We obtained very good technical performance of FI (95% sensitivity, 98% specificity, and a kappa of 0.92, even in a subgroup of weakly positive samples. A significant correlation between quantification of FI and IIF ANA titers was found (Spearman's ρ=0.80, P<0.0001. Clinical performance of ICARE was validated on a cohort of patients with SLE corroborating the fact that FI could represent an attractive alternative for the evaluation of antibody titer. Conclusion. Our results represent a major step for automated quantification of IIF ANA, opening attractive perspectives such as rapid sample screening and laboratory standardization.

  6. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays

    OpenAIRE

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2015-01-01

    BACKGROUND: We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. METHODS: Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automat...

  7. Human cryptosporidiosis: detection of specific antibodies in the serum by an indirect immunofluorescence

    Directory of Open Access Journals (Sweden)

    Braz Lúcia M.A.

    1996-01-01

    Full Text Available Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.

  8. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    Science.gov (United States)

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  9. Performance Characteristics of Different Anti-Double-Stranded DNA Antibody Assays in the Monitoring of Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Michael Mahler

    2017-01-01

    Full Text Available Objective. We sought to evaluate different anti-double-stranded DNA assays for their performance characteristics in monitoring disease activity fluctuations in systemic lupus erythematosus (SLE. Methods. 36 active SLE patients were followed monthly. At each study visit (total n=371, blood was collected and disease activity was scored using the SELENA-SLEDAI (excluding anti-dsDNA or complement components and by a physician’s global assessment (PGA. Four anti-dsDNA tests were compared. Linear mixed-effects models with random intercept and fixed slopes were used to evaluate the relationship between the longitudinal fluctuations of disease activity and anti-dsDNA titers. Results. At enrollment, positivity for QUANTA Lite and high-avidity anti-dsDNA assay was both 64% and significantly lower than anti-dsDNA positivity by QUANTA Flash (83% and CLIFT (96%. Linear mixed-effects modeling indicated that the change in clinical SELENA-SLEDAI scores was associated with the titers of all anti-dsDNA with QUANTA Flash yielding the highest marginal R2 (0.15; p<0.01. QUANTA Flash was the only anti-dsDNA assay significantly associated with the change in PGA (marginal R2=0.05; p<0.01. Conclusion. These data indicate that anti-dsDNA antibodies determined by QUANTA Flash have a value in monitoring SLE disease activity.

  10. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Vanparys, Caroline, E-mail: caroline.vanparys@ua.ac.be [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Depiereux, Sophie; Nadzialek, Stephanie [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); Robbens, Johan; Blust, Ronny [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Kestemont, Patrick [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); De Coen, Wim [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); European Chemicals Agency (ECHA), Helsinki (Finland)

    2010-09-15

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC{sub 50} value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R{sup 2} = 0.98), the estrogen receptor (ER) binding (R{sup 2} = 0.84) and the ER transcription activation assay (R{sup 2} = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies

  11. Analytical and diagnostic performance of a qPCR assay for Ichthyophonus spp. compared to the tissue culture 'gold standard'.

    Science.gov (United States)

    Lowe, Vanessa C; Hershberger, Paul K; Friedman, Carolyn S

    2018-06-04

    Parasites of the genus Ichthyophonus infect many fish species and have a non-uniform distribution within host tissues. Due in part to this uneven distribution, the comparative sensitivity and accuracy of using molecular-based detection methods versus culture to estimate parasite prevalence is under debate. We evaluated the analytical and diagnostic performance of an existing qPCR assay in comparison to the 'gold standard' culture method using Pacific herring Clupea pallasii with known exposure history. We determined that the assay is suitable for use in this host, and diagnostic specificity was consistently high (>98%) in both heart and liver tissues. Diagnostic sensitivity could not be fully assessed due to low infection rates, but our results suggest that qPCR is not as sensitive as culture under all circumstances. Diagnostic sensitivity of qPCR relative to culture is likely affected by the amount of sample processed. The prevalence values estimated by the 2 methods were not significantly different when sample amounts were equal (heart tissue), but when the assayed sample amounts were unequal (liver tissue), the culture method detected a significantly higher prevalence of the parasite than qPCR. Further, culture of liver also detected significantly more Ichthyophonus infections than culture of heart, suggesting that the density and distribution of parasites in tissues also plays a role in assay sensitivity. This sensitivity issue would be most problematic for fish with light infections. Although qPCR does not detect the presence of a live organism, DNA-based pathogen detection methods provide the opportunity for alternate testing strategies when culture is not possible.

  12. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    International Nuclear Information System (INIS)

    Vanparys, Caroline; Depiereux, Sophie; Nadzialek, Stephanie; Robbens, Johan; Blust, Ronny; Kestemont, Patrick; De Coen, Wim

    2010-01-01

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC 50 value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R 2 = 0.98), the estrogen receptor (ER) binding (R 2 = 0.84) and the ER transcription activation assay (R 2 = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies, supports the use of

  13. Immunofluorescent determination of wheat protein in meat products

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-02-01

    foodstuffs is relatively difficult because of the fact that they occur in trace amounts and are often masked by various parts of the product. This paper deals with detection of wheat protein in meat products bought in the retail network of the Czech Republic. Ten cooked meat products, especially types of sausages and soft salami which stated wheat protein in their composition, were examined. The samples were processed using the method of immunofluorescence and stained with Texas Red fluorochrome. The presence of wheat protein was demonstrated in all the examined meat products. From the results it follows that the method of immunofluorescence is suitable for detection of wheat protein in meat products. Normal 0 21 false false false CS JA X-NONE

  14. Area-under-the-curve monitoring of cyclosporine therapy: Performance of different assay methods and their target concentrations

    International Nuclear Information System (INIS)

    Grevel, J.; Napoli, K.L.; Gibbons, S.; Kahan, B.D.

    1990-01-01

    The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3 H and 125 I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz ( 3 H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3 H and 125 I tracer) measured significantly higher concentrations than the liquid chromatography

  15. Direct immunofluorescence of normal skin in rheumatoid arthritis.

    Science.gov (United States)

    Fitzgerald, O M; Barnes, L; Woods, R; McHugh, L; Barry, C; O'Loughlin, S

    1985-11-01

    The clinical significance of previously described immunoglobulin and complement deposition in the superficial dermal vessel walls of patients with rheumatoid arthritis is unknown. In the present study, skin biopsies were obtained from the normal forearm and buttock of 48 unselected patients with rheumatoid arthritis and were examined by direct immunofluorescence (IF) for the presence of immunoglobulin (IgG,A,M) and complement (C3) in the vessel walls. Deposits of C3, IgM or IgG were detected in 10 patients. Five patients had deposits at the forearm sample alone, four patients had deposits at both biopsy sites, while one patient was positive at the buttock alone. Clinical features were similar in patients with and without vessel IF. However, patients with IF were significantly more seropositive with lower levels of complement and raised levels of serum IgA and IgM. There was also an increased level of circulating IgG immune complexes in these patients. Further analysis following exclusion of seronegative patients revealed similar results. This study suggests that the presence of vessel IF identifies a subgroup of patients who have evidence of more severe immunological disturbance.

  16. [Standardized indirect immunofluorescence. Differentiation of mitochondrial, microsomal and ribosomal antibodies].

    Science.gov (United States)

    Storch, W

    1977-02-15

    By an extensive standardisation of the indirect immunofluorescence for the demonstration espeially of mitochondrial antibodies we succeeded in recognizing atypical fluorescence patterns and in describing their exact localisation. On the basis of absorption studies with mitochondrias, microsomas and ribosomas by comparative observation of sections of liver, stomach and kidneys of rats the preferred sort of reaction and the intensity of fluorescence of antibodies against mitochondria, microsomas and ribosomas were empirically established. Antimitochondrial antibodies react above all with the parietal cells of the stomach and the distal epithelia of the tubulus of the kidney. Antibodies against microsomas of liver and kidney are characterized by a brilliant diffuse cytoplasmatic fluorescence of the hepatocytes and by a comparatively weaker fluorescence of exclusively proximal tubuli of the kidneys of rats. Antibodies against ribosomas lead to a fluorescence especially of the main cells of the stomach. The differentiation of several cytoplasmatic antibodies is among others of interest for the diagnosis of certain autoimmune diseases. Although there are numerous still unclear findings and "overlap" phenomena the existence of high titre antibodies against mitochondrias speaks for a primarily biliary cirrhosis or a pseudo-LE-syndrome, the existence of antibodies against microsomas of kidney and liver of rats for a special form of a chronically active hepatitis and the existence of the very rare antibodies against ribosomas for an active lupus erythematodes disseminatus.

  17. Clinical and analytical performance of the BD Onclarity™ HPV assay for detection of CIN2+ lesions on SurePath samples

    DEFF Research Database (Denmark)

    Ejegod, Ditte Møller; Junge, Jette; Franzmann, Maria

    2016-01-01

    BACKGROUND: The novel BD Onclarity(TM) HPV assay (Onclarity) on the BD Viper™ LT system (BD Diagnostics, Sparks, MD), detects E6/E7 DNA from 13 high-risk HPV genotypes and HPV66. We compared the analytical and clinical performance of the Onclarity Assay to that of Hybrid Capture 2 and LINEAR ARRAY...

  18. Performance of the Epstein-Barr Virus and Herpes Simplex Virus Immunoglobulin M Assays on the Liaison Platform with Sera from Patients Displaying Acute Parvovirus B19 Infection▿

    Science.gov (United States)

    Costa, Elisa; Tormo, Nuria; Clari, María Ángeles; Bravo, Dayana; Muñoz-Cobo, Beatriz; Navarro, David

    2009-01-01

    Acute parvovirus B19 infection has been reported to cause false-positive results frequently in the Epstein-Barr (EBV) and herpes simplex virus (HSV) immunoglobulin M (IgM) assays from DiaSorin performed on the Liaison platform. We tested 65 sera from patients with a presumptive or conclusive diagnosis of acute parvovirus B19 infection in both assays and obtained no false-positive results in the EBV IgM test and 10.4% nonspecific reactivities in the HSV IgM assay. Our data support the specificity of both assays in this clinical setting. PMID:19571110

  19. A molecular method for typing Herpes simplex virus isolates as an alternative to immunofluorescence methods

    Directory of Open Access Journals (Sweden)

    Abraham A

    2009-01-01

    Full Text Available Background: Typing of Herpes simplex virus (HSV isolates is required to identify the virus isolated in culture. The methods available for this include antigen detection by immunofluorescence (IF assays and polymerase chain reaction (PCR. This study was undertaken to standardize a molecular method for typing of HSV and compare it with a commercial IF reagent for typing. Objectives: To compare a molecular method for typing HSV isolates with a monoclonal antibody (MAb based IF test. Study design : This cross-sectional study utilized four reference strains and 42 HSV isolates obtained from patients between September 1998 and September 2004. These were subjected to testing using an MAb-based IF test and a PCR that detects the polymerase ( pol gene of HSV isolates. Results: The observed agreement of the MAb IF assay with the pol PCR was 95.7%. Fifty four point eight percent (23/42 of isolates tested by IF typing were found to be HSV-1, 40.5% (17/42 were HSV-2, and two (4.8% were untypable using the MAb IF assay. The two untypable isolates were found to be HSV-2 using the pol PCR. In addition, the cost per PCR test for typing is estimated to be around Rs 1,300 (USD 30, whereas the cost per MAb IF test is about Rs 1,500 (USD 35 including all overheads (reagents, instruments, personnel time, and consumables. Conclusion: The pol PCR is a cheaper and more easily reproducible method for typing HSV isolates as compared to the IF test. It could replace the IF-based method for routine typing of HSV isolates as availability of PCR machines (thermal cyclers is now more widespread than fluorescence microscopes in a country like India.

  20. High performance liquid chromatographic-mass spectrometric assay for the quantitation of BMS-204352 in dog K(3)EDTA plasma.

    Science.gov (United States)

    Yao, Ming; Mantha, Subbarao; Shah, Vinod R; Vachharajani, Nimish N; Arnold, Mark E; Pursley, Janice M; Srinivas, Nuggehally R

    2002-05-01

    A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and

  1. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical

  2. Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

    Science.gov (United States)

    Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong

    2016-10-01

    Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The performance of the SEPT9 gene methylation assay and a comparison with other CRC screening tests: A meta-analysis.

    Science.gov (United States)

    Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin

    2017-06-08

    The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.

  4. Calibration of UFBC counters and their performance in the assay of large mass plutonium samples

    International Nuclear Information System (INIS)

    Verrecchia, G.P.D.; Smith, B.G.R.; Cranston, R.

    1991-01-01

    This paper reports on the cross-calibration of four Universal Fast Breeder reactor assembly coincidence (UFBC) counters using multi-can containers of Plutonium oxide powders with masses between 2 and 12 Kg of plutonium and a parametric study on the sensitivity of the detector response to the positioning or removal and substitution of the material with empty cans. The paper also reports on the performance of the UFBC for routine measurements on large mass, multi-can containers of plutonium oxide powders and compares the results to experience previously obtained in the measurement of fast reactor type fuel assemblies in the mass range 2 to 16 Kg of plutonium

  5. Non-Tuberculous Mycobacteria and the Performance of Interferon Gamma Release Assays in Denmark

    DEFF Research Database (Denmark)

    Hermansen, Thomas Stig; Thomsen, Vibeke Østergaard; Lillebaek, Troels

    2014-01-01

    , nationwide patient data on positive NTM cultures (n = 925) were combined with nationwide data on QFT results (n = 16,133), both retrieved from the International Reference Laboratory of Mycobacteriology, Denmark. A total of 112 patients with NTM infections had a QFT performed, 53 patients had definite NTM...... disease, 10 had possible disease and 49 had NTM colonization. RESULTS: QFT was positive in 8% (4/53) of patients with definite disease, 40% (4/10) with possible disease and 31% (15/49) with colonization. Positivity rate was lowest among patients with definite disease infected with NTM without the RD1...

  6. Self-motivated and stress-response performance assays in mice are age-dependent.

    Science.gov (United States)

    Ge, Xuan; Ciol, Marcia A; Pettan-Brewer, Christina; Goh, Jorming; Rabinovitch, Peter; Ladiges, Warren

    2017-05-01

    Chronic health conditions of the elderly lead to limitations in physical activity with disability, anxiety, and increased need for medical care and assisted living conditions. Physical performance tests are used to screen for pending loss of mobility and can serve as endpoints to monitor the effectiveness of intervention measures. Since limited mobility is associated with the physical and mental health of a person, evaluation of this in preclinical aging studies in mice will provide a translational approach for testing new intervention strategies. We assessed physiological parameters in 4, 12, 20 and 28month old C57BL/6 and CB6F1 male mice using a rotating rod, a free running wheel, and a photo beam activity field, designed to determine changes in coordinated walking ability, self-motivated running distance, and anxiety response to a novel environment, respectively. Older mice showed decreased coordinated walking times and decreased running distances, predictive of physical performance ability and motivation in the elderly. Changes in both lateral and vertical movements were observed in a novel cage environment suggesting different levels of anxiety. Because the genetic background of the two mouse strains influenced test results in an age-dependent manner, it is imperative to recognize that diverse genetic backgrounds in mice may yield different data in preclinical studies and would need to be interpreted individually for translational applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    Science.gov (United States)

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  8. Assessment of a robust model protocol with accelerated throughput for a human recombinant full length estrogen receptor-alpha binding assay: protocol optimization and intralaboratory assay performance as initial steps towards validation.

    Science.gov (United States)

    Freyberger, Alexius; Wilson, Vickie; Weimer, Marc; Tan, Shirlee; Tran, Hoai-Son; Ahr, Hans-Jürgen

    2010-08-01

    Despite about two decades of research in the field of endocrine active compounds, still no validated human recombinant (hr) estrogen receptor-alpha (ERalpha) binding assay is available, although hr-ERalpha is available from several sources. In a joint effort, US EPA and Bayer Schering Pharma with funding from the EU-sponsored 6th framework project, ReProTect, developed a model protocol for such a binding assay. Important features of this assay are the use of a full length hr-ERalpha and performance in a 96-well plate format. A full length hr-ERalpha was chosen, as it was considered to provide the most accurate and human-relevant results, whereas truncated receptors could perform differently. Besides three reference compounds [17beta-estradiol, norethynodrel, dibutylphthalate] nine test compounds with different affinities for the ERalpha [diethylstilbestrol (DES), ethynylestradiol, meso-hexestrol, equol, genistein, o,p'-DDT, nonylphenol, n-butylparaben, and corticosterone] were used to explore the performance of the assay. Three independent experiments per compound were performed on different days, and dilutions of test compounds from deep-frozen stocks, solutions of radiolabeled ligand and receptor preparation were freshly prepared for each experiment. The ERalpha binding properties of reference and test compounds were well detected. As expected dibutylphthalate and corticosterone were non-binders in this assay. In terms of the relative ranking of binding affinities, there was good agreement with published data obtained from experiments using a human recombinant ERalpha ligand binding domain. Irrespective of the chemical nature of the compound, individual IC(50)-values for a given compound varied by not more than a factor of 2.5. Our data demonstrate that the assay was robust and reliably ranked compounds with strong, weak, and no affinity for the ERalpha with high accuracy. It avoids the manipulation and use of animals, i.e., the preparation of uterine cytosol as

  9. Optimization and development of a high-performance liquid chromatography-based one-site immunometric assay with chemiluminescence detection

    International Nuclear Information System (INIS)

    Oates, Matthew R.; Clarke, William; Zimlich, Alden; Hage, David S.

    2002-01-01

    Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was L-thyroxine (also known as T 4 ). In this technique, a sample containing thyroxine was first combined with an excess of anti-T 4 antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T 4 . The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T 4 in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries

  10. A high-performance liquid chromatography-based radiometric assay for acyl-CoA:alcohol transacylase from jojoba.

    Science.gov (United States)

    Garver, W S; Kemp, J D; Kuehn, G D

    1992-12-01

    Acyl-CoA:alcohol transacylase catalyzes the final step in the biosynthesis of storage liquid wax esters from acyl-CoA fatty acids and fatty alcohols in a limited number of microbes, algae, and Simmondsia chinensis Link (jojoba). An improved and automated method of enzyme assay for this catalyst from cotyledons of jojoba is described. The assay method uses reversed-phase C18 high performance liquid chromatography (HPLC) to separate the labeled C30:1 liquid wax product, [14C]-dodecanyl-octadecenoate, from the unreacted substrate, [14C]octadecenoyl-CoA (oleyl-CoA), and other components produced from enzymes present in the crude homogenate of jojoba cotyledons, including [14C]-octadecenoic acid (oleic acid) and [14C]octadecenol (oleyol). Methods are also described for microscale chemical synthesis in one vessel of 14C-radiolabeled substrates and products for the transacylase. These labeled reagents are required to confirm the HPLC separations of reaction products. The radioactive components are quantitated using an on-line flow-through scintillation detector enabling sensitive and precise analysis of the reaction products.

  11. High-performance liquid chromatographic assay for two rifamycin-derived hypocholesterolemic agents in liver and biological fluids.

    Science.gov (United States)

    Moore, D J; Perrino, P J; Klerer, C P; Robertson, P

    1993-02-26

    CGP 43371 (compound I), a mono-pivaloyl oxazole derivative of a 3-piperazino-rifamycin, has been in clinical trials as a potential hypocholesterolemic agent. A reversed-phase high-performance liquid chromatographic (HPLC) assay was developed using a C18 column and a gradient solvent system of methanol-0.1 M sodium acetate, pH 4.5, at a flow-rate of 1 ml/min. The compound and internal standard (rifampicin) were detected by their ultraviolet absorption at 254 nm. Isolation of the compounds from plasma and liver homogenates was accomplished by precipitation of proteins with acetonitrile, followed by evaporation under nitrogen and reconstitution in methanol. Bile, lymph and urine were injected onto the HPLC column without pretreatment. Calibration curves were linear (r > 0.999) over the concentration range 0.25-20.0 micrograms/ml. The assay procedure was also applicable to other rifamycin derivatives and was able to distinguish between molecular species containing small differences in functionality.

  12. A high performance liquid chromatographic assay of Mefloquine in saliva after a single oral dose in healthy adult Africans

    Directory of Open Access Journals (Sweden)

    Gbotosho Grace O

    2012-02-01

    Full Text Available Abstract Background Mefloquine-artesunate is a formulation of artemisinin based combination therapy (ACT recommended by the World Health Organization and historically the first ACT used clinically. The use of ACT demands constant monitoring of therapeutic efficacies and drug levels, in order to ensure that optimum drug exposure is achieved and detect reduced susceptibility to these drugs. Quantification of anti-malarial drugs in biological fluids other than blood would provide a more readily applicable method of therapeutic drug monitoring in developing endemic countries. Efforts in this study were devoted to the development of a simple, field applicable, non-invasive method for assay of mefloquine in saliva. Methods A high performance liquid chromatographic method with UV detection at 220 nm for assaying mefloquine in saliva was developed and validated by comparing mefloquine concentrations in saliva and plasma samples from four healthy volunteers who received single oral dose of mefloquine. Verapamil was used as internal standard. Chromatographic separation was achieved using a Hypersil ODS column. Results Extraction recoveries of mefloquine in plasma or saliva were 76-86% or 83-93% respectively. Limit of quantification of mefloquine was 20 ng/ml. Agreement between salivary and plasma mefloquine concentrations was satisfactory (r = 0.88, p Conclusion Disposition of mefloquine in saliva paralleled that in plasma, making salivary quantification of mefloquine potentially useful in therapeutic drug monitoring.

  13. Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

    International Nuclear Information System (INIS)

    Attas, E.M.; Bialas, E.; Rhodes, M.J.

    2013-01-01

    Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels

  14. A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays

    Directory of Open Access Journals (Sweden)

    Linda G. Lee

    2013-10-01

    Full Text Available We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.

  15. Immunodiagnosis of Human Fascioliasis: An Update of Concepts and Performances of the Serological Assays

    Science.gov (United States)

    Khabisi, Samaneh Abdolahi

    2017-01-01

    Human Fascioliasis (HF) is a foodborne neglected parasitic disease caused by Fasciola hepatica and Fasciola gigantica. New epidemiological data suggest that the endemic areas of the disease are expanding and HF is being reported from areas where it was previously not observed. Diagnosis of HF is challenging. Performances of parasitological approaches, based on the detection of parasite’s egg in the stool, are not satisfactory. Currently serological methods for the diagnosis of HF are mainly based on detection of anti-Fasciola antibodies in serum. Although, there have been some improvement in the development of immunological diagnostic tests for the diagnosis of HF, yet these tests suffer from insufficiency in sensitivity or/and specificity. Detection of antigens, rather than antibodies, seems to be a suitable approach in the diagnosis of HF. Antigen can be detected in sera or stool of the fascioliasis patients. Circulating antigen in serum disappears within a short time and most of the circulating antigens are in immune complex forms which are not freely available to be detected. Therefore, antigenemia might not be an appropriate method for the diagnosis of HF. Detection of antigen in stool (coproantigens) seems to be a suitable alternative method for the diagnosis of HF. Recent data provided convincing evidence that detection of coproantigen improved and simplified the diagnosis of HF. The present review highlights the new achievements in designing and improvement of diagnostic approaches for the immunodiagnosis of HF. Moreover, current status of the available immunodiagnostic techniques for the diagnosis of HF, their strengths and weaknesses has been discussed. PMID:28764235

  16. [Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay].

    Science.gov (United States)

    Gao, Nan; Huang, Li-Qin; Wang, Rui; Jia, Jun-Jie; Wu, Shuo; Zhang, Jing; Ge, Hong-Wei

    2018-06-01

    To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA). The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017. There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test. The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.

  17. Staining pattern classification of antinuclear autoantibodies based on block segmentation in indirect immunofluorescence images.

    Directory of Open Access Journals (Sweden)

    Jiaqian Li

    Full Text Available Indirect immunofluorescence based on HEp-2 cell substrate is the most commonly used staining method for antinuclear autoantibodies associated with different types of autoimmune pathologies. The aim of this paper is to design an automatic system to identify the staining patterns based on block segmentation compared to the cell segmentation most used in previous research. Various feature descriptors and classifiers are tested and compared in the classification of the staining pattern of blocks and it is found that the technique of the combination of the local binary pattern and the k-nearest neighbor algorithm achieve the best performance. Relying on the results of block pattern classification, experiments on the whole images show that classifier fusion rules are able to identify the staining patterns of the whole well (specimen image with a total accuracy of about 94.62%.

  18. Antibodies to UV irradiated DNA: the monitoring of DNA damage by ELISA and indirect immunofluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Wani, A A; Gibson-D' Ambrosio, R E; D' Ambrosio, S M [Ohio State Univ., Columbus (USA). Dept. of Radiology

    1984-10-01

    The enzyme-linked immunosorbant assay (ELISA) was modified to (1) characterize antibodies raised in rabbits against UV-irradiated single-stranded DNA (UVssDNA) complexed with methylated BSA and (2) directly detect pyrimidine dimers in irradiated DNA. The antisera specifically bound to UVssDNA, UVpoly(dT) and to a limited extent to UVdsDNA and UVpoly(dC). Fifty per cent of the maximum antibody binding was observed at a 1-5000 dilution against UVssDNA. Binding to ssDNA and poly(dT) was observed only at much higher concentrations of antibody, whereas no binding to double stranded DNA (dsDNA) was observed. The extent of binding of the antibody was dependent on the UV dose to DNA and the concentration of antigen immobilized on the plate. The ability of various irradiated molecules, DNA, homopolymers and linkers to act as inhibitors of antibody binding establishes that the antigenic determinants are mainly thymine homodimers with lower affinity for cytosine dimers. Potential usefulness of the antibodies to directly quantitate pyrimidine dimers in cells exposed to UV radiation was determined by indirect immunofluorescence. Flow cytometric analysis of immunostained human lymphocytes irradiated with 254 nm radiation indicated that greater than 50% of the population had significantly higher fluorescent intensity than unirradiated cells.

  19. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    Science.gov (United States)

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  20. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  1. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    Science.gov (United States)

    Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.

    2013-01-01

    Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.

  2. Comparison among performances of a ligase chain reaction-based assay and two enzyme immunoassays in detecting Chlamydia trachomatis in urine specimens from men with nongonococcal urethritis.

    Science.gov (United States)

    Deguchi, T; Yasuda, M; Uno, M; Tada, K; Iwata, H; Komeda, H; Maeda, S; Latila, V; Saito, I; Kawada, Y

    1996-01-01

    We evaluated the performances of a ligase chain reaction (LCR)-based assay and two enzyme immunoassays (Chlamydiazyme and IDEIA) in the detection of Chlamydia trachomatis in urine specimens. We compared the results of testing urine specimens by these assays with those of urethral swab culture by examining samples from 131 men with nongonococcal urethritis. Discrepant results were analyzed by testing urethral swab specimens for C. trachomatis by a PCR-based assay. After the resolution of discrepant results, the sensitivity of urethral swab culture was 85.3%, whereas those of the LCR assay, Chlamydiazyme, and IDEIA with urine specimens were 94.1, 82.4, and 94.1%, respectively. The LCR assay and IDEIA were more sensitive than was urethral swab culture. In addition, the LCR assay, with a sensitivity equal to that of IDEIA, was more specific. Overall, the LCR assay proved to be superior to the enzyme immunoassays in detecting C. trachomatis in urine specimens. Testing urine specimens by LCR assay should be a helpful alternative method for diagnosing C. trachomatis urethral infection in men with nongonococcal urethritis. PMID:8784574

  3. An expert protocol for immunofluorescent detection of calcium channels in tsA-201 cells.

    Science.gov (United States)

    Koch, Peter; Herzig, Stefan; Matthes, Jan

    Pore-forming subunits of voltage gated calcium channels (VGCC) are large membrane proteins (260kDa) containing 24 transmembrane domains. Despite transfection with viral promoter driven vectors, biochemical analysis of VGCC is often hampered by rather low expression levels in heterologous systems rendering VGCC challenging targets. Especially in immunofluorescent detection, calcium channels are demanding proteins. We provide an expert step-by-step protocol with adapted conditions for handling procedures (tsA-201 cell culture, transient transfection, incubation time and temperature at 28°C or 37°C and immunostaining) to address the L-type calcium-channel pore Ca v 1.2 in an immunofluorescent approach. We performed immunocytochemical analysis of Ca v 1.2 expression at single-cell level in combination with detection of different markers for cellular organelles. We show confluency levels and shapes of tsA-201 cells at different time points during an experiment. Our experiments reveal sufficient levels of Ca v 1.2 protein and a correct Ca v 1.2 expression pattern in polygonal shaped cells already 12h after transfection. A sequence of elaborated protocol modifications allows subcellular localization analysis of Ca v 1.2 in an immunocytochemical approach. We provide a protocol that may be used to achieve insights into physiological and pathophysiological processes involving voltage gated calcium channels. Our protocol may be used for expression analysis of other challenging proteins and efficient overexpression may be exploited in related biochemical techniques requiring immunolabels. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Performance of two Aspergillus IgG EIA assays compared with the precipitin test in chronic and allergic aspergillosis.

    Science.gov (United States)

    Baxter, C G; Denning, D W; Jones, A M; Todd, A; Moore, C B; Richardson, M D

    2013-04-01

    Detection of Aspergillus IgG antibodies is important in the diagnosis of chronic pulmonary aspergillosis and allergic bronchopulmonary aspergillosis. Immunoprecipitation techniques to detect these antibodies appear to lack sensitivity and accurate quantitation compared with enzyme immunoassays (EIA). This study assessed the performance of two commercial EIAs compared with counterimmunoelectrophoresis (CIE). This was a prospective cohort study of 175 adult patients with chronic or allergic pulmonary aspergillosis. Aspergillus IgG antibodies were detected using CIE, Phadia ImmunoCap Aspergillus IgG and Bio-Rad Platelia Aspergillus IgG. Inter-assay reproducibility was determined for each method and 25 patients had two serum samples analysed within a 6-month interval. When compared with CIE, both ImmunoCap and Platelia Aspergillus IgG had good sensitivity (97 and 93%, respectively) for detection of Aspergillus IgG antibodies. The level of agreement between the two EIAs for positive results was good, but the concentration of antibodies was not correlated between the tests or with CIE titre. ImmunoCap IgG inter-assay coefficient of variation was 5%, whereas Platelia IgG was 33%. Median ImmunoCap IgG values for CPA and allergic aspergillosis were 95 and 32 mg/L, respectively, whereas Platelia IgG values were >80 and 6 AU/mL. The direction of CIE titre change over 6 months was mirrored by ImmunoCap IgG levels in 92% of patients, and by Platelia IgG in 72% of patients. Both ImmunoCap and Platelia Aspergillus IgG EIAs are sensitive measures of Aspergillus IgG antibodies compared with CIE. However, ImmunoCap appears to have better reproducibility and may be more suitable for monitoring patient disease. © 2012 The Authors Clinical Microbiology and Infection © 2012 European Society of Clinical Microbiology and Infectious Diseases.

  5. Translating tumor biology into personalized treatment planning: analytical performance characteristics of the Oncotype DX? Colon Cancer Assay

    OpenAIRE

    Clark-Langone, Kim M; Sangli, Chithra; Krishnakumar, Jayadevi; Watson, Drew

    2010-01-01

    Abstract Background The Oncotype DX® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology unde...

  6. High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Qunlin; Lian Mei; Liu Lijuan; Cui Hua

    2005-01-01

    A new method for the simultaneous determination of parabens including methylparaben, ethylparaben, propylparaben, and butylparaben by high-performance liquid chromatography (HPLC) coupled with chemiluminescence detection was developed. The procedure was based on the chemiluminescent enhancement by parabens of the cerium(IV)-rhodamine 6G system in the strong sulfuric acid medium. The good separation of parabens was carried out with an isocratic elution using a mixture of methanol and water (60:40, v/v) within 8.5 min. Under the optimized conditions, a linear working range extends three orders of magnitude with the relative standard deviations of intra- and inter-day precision below 4.5%, and the detection limits were 1.9 x 10 -9 , 2.7 x 10 -9 , 3.9 x 10 -9 , and 5.3 x 10 -9 g ml -1 for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively. The chemiluminescence reaction was well compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the assay of parabens in wash-off cosmetic products and foods with the minimal sample preparation

  7. Enzyme-linked immunosorbent assay (ELISA for measles antibody: a comparison with haemagglutination inhibition, immunofluorescence and plaque neutralization tests Reação imunoenzimática (ELISA para detecção de anticorpos para o vírus do sarampo: comparação com reações de inibição da hema-glutinação, imunofluorescência indireta e neutralização de placas

    Directory of Open Access Journals (Sweden)

    Vanda Akico Ueda Fick de Souza

    1991-02-01

    Full Text Available An enzyme-linked immunosorbent assay (ELISA for measles antibodies was compared with Plaque Neutralization (PRN, Haemagglutination inhibition (HI and Fluorescent antibody (IFA tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%. IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.A reação imunoenzimática (ELISA para determinação de anticorpos para o vírus do sarampo foi comparada com a reação de neutralização de placas (RNP, inibição da hemaglutinação (RIH e imunofluorescência indireta (RIF. Das 179 amostras positivas pela RNP, somente 2, com títulos iguais a 8, se apresentaram negativas por ELISA (copositividade de 98.9%. A RIF e RIH apresentaram, respectivamente, copositividade de 93.3 e 82.7%. ELISA apresentou sensibilidade equivalente à complexa RNP, boa reprodutibilidade e representa uma alternativa para a detecção de baixos títulos de anticorpos contra o sarampo.

  8. Performance evaluation of the Aptima HSV-1 and 2 assay for the detection of HSV in cutaneous and mucocutaneous lesion specimens.

    Science.gov (United States)

    Sam, Soya S; Caliendo, Angela M; Ingersoll, Jessica; Abdul-Ali, Deborah; Kraft, Colleen S

    Timely and precise laboratory diagnosis of Herpes simplex viruses (HSV) is required to guide clinical management. The study evaluated limit of detection (LOD) and performance characteristics of the Aptima HSV 1 & 2 assay in comparison to four assays. The multi-center study compared qualitative detection of HSV-1 and 2 by the Aptima HSV-1 and 2 assay (Hologic) to ELVIS culture, Lyra Direct (Quidel), AmpliVue (Quidel) and a laboratory developed test (LDT). LOD was performed using VTM and STM diluted viral concentrations and clinical performance was evaluated using 505 swab specimens. The Aptima LOD studies performed showed a lower detection limit for STM specimens as 1450 copies/mL and 430 copies/mL for HSV1 and HSV-2 respectively; the LOD for VTM specimens was 9370 copies/mL and 8045 copies/mL for HSV-1 and HSV-2 respectively. When the assays were analyzed based on the positive consensus result established the Aptima had 95% of percent positive agreement (PPA) and 100% negative percent agreement (NPA) for the HSV-1. For the HSV-2, the PPA and NPA for Aptima were 96% and 100% respectively. AmpliVue had 1.8% invalid rate, while Lyra had no invalid results but an inhibition rate of 0.8%. Aptima and LDT did not have any invalid or inhibited results. The results indicate that the Aptima HSV-1 & 2 assay is sensitive and the performance characteristics of the Aptima assay is comparable to the assays analyzed for the detection and differentiation of HSV-1 and 2 from cutaneous and mucocutaneous lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Highly sensitive reversed-phase high-performance liquid chromatography assay for the detection of Tamm-Horsfall protein in human urine.

    Science.gov (United States)

    Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo

    2016-01-01

    Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.

  10. Performance of 2 commercial real-time polymerase chain reaction assays for the detection of Aspergillus and Pneumocystis DNA in bronchoalveolar lavage fluid samples from critical care patients.

    Science.gov (United States)

    Orsi, Carlotta Francesca; Gennari, William; Venturelli, Claudia; La Regina, Annunziata; Pecorari, Monica; Righi, Elena; Machetti, Marco; Blasi, Elisabetta

    2012-06-01

    This article investigates the performance of 2 commercial real-time polymerase chain reaction (PCR) assays, MycAssay™ Aspergillus (Myc(Asp)Assay) and MycAssay™ Pneumocystis (Myc(PCP)Assay), on the ABI 7300 platform for the detection of Aspergillus (Asp) or Pneumocystis jirovecii (Pj) DNA in bronchoalveolar lavage (BAL) samples from 20 patients. Operationally, patients enrolled were clustered into 3 groups: invasive aspergillosis group (IA, 7 patients), Pj pneumonia group (PCP, 8 patients), and negative control group (5 patients). All the IA patients were Myc(Asp)Assay positive, whereas 12 non-IA patients returned negative PCR results. Furthermore, 7 of 8 PCP patients were Myc(PCP)Assay positive, while 9 non-PCP patients were PCR negative. In conclusion, these data provide an early indication of the effectiveness of both the Myc(Asp)Assay and Myc(PCP)Assay on the ABI 7300 platform for the detection of either Asp or Pj DNA in BAL from patients with deep fungal infections. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Comparison of the performance in detection of HPV infections between the high-risk HPV genotyping real time PCR and the PCR-reverse dot blot assays.

    Science.gov (United States)

    Zhang, Lahong; Dai, Yibei; Chen, Jiahuan; Hong, Liquan; Liu, Yuhua; Ke, Qiang; Chen, Yiwen; Cai, Chengsong; Liu, Xia; Chen, Zhaojun

    2018-01-01

    A new multiplex real-time PCR assay, the high-risk HPV genotyping real time PCR assay (HR HPV RT-PCR), has been developed to detect 15 high-risk HPV types with respective viral loads. In this report, a total of 684 cervical specimens from women diagnosed with vaginitis were assessed by the HR HPV RT-PCR and the PCR reaction and reverse dot blot (PCR-RDB) assays, using a PCR-sequencing method as a reference standard. A total coincidence of 97.7% between the HR HPV RT PCR and the PCR-RDB assays was determined with a Kappa value of 0.953. The HR HPV RT PCR assay had sensitivity, specificity, and concordance rates (accuracy) of 99.7%, 99.7%, and 99.7%, respectively, as confirmed by PCR-sequencing, while the PCR-RDB assay had respective rates of 98.8%, 97.1%, and 98.0%. The overall rate of HPV infection, determined by PCR-sequencing, in women diagnosed with vaginitis was 49.85%, including 36.26% of single infection and 13.6% of multiple infections. The most common infections among the 15 high-risk HPV types in women diagnosed with vaginitis were HPV-52, HPV-16, and HPV-58, with a total detection rate of 10.23%, 7.75%, and 5.85%, respectively. We conclude that the HR HPV RT PCR assay exhibits better clinical performance than the PCR-RDB assay, and is an ideal alternative method for HPV genotyping. In addition, the HR HPV RT PCR assay provides HPV DNA viral loads, and could serve as a quantitative marker in the diagnosis and treatment of single and multiple HPV infections. © 2017 Wiley Periodicals, Inc.

  12. A sensitive, reproducible and objective immunofluorescence analysis method of dystrophin in individual fibers in samples from patients with duchenne muscular dystrophy.

    Directory of Open Access Journals (Sweden)

    Chantal Beekman

    Full Text Available Duchenne muscular dystrophy (DMD is characterized by the absence or reduced levels of dystrophin expression on the inner surface of the sarcolemmal membrane of muscle fibers. Clinical development of therapeutic approaches aiming to increase dystrophin levels requires sensitive and reproducible measurement of differences in dystrophin expression in muscle biopsies of treated patients with DMD. This, however, poses a technical challenge due to intra- and inter-donor variance in the occurrence of revertant fibers and low trace dystrophin expression throughout the biopsies. We have developed an immunofluorescence and semi-automated image analysis method that measures the sarcolemmal dystrophin intensity per individual fiber for the entire fiber population in a muscle biopsy. Cross-sections of muscle co-stained for dystrophin and spectrin have been imaged by confocal microscopy, and image analysis was performed using Definiens software. Dystrophin intensity has been measured in the sarcolemmal mask of spectrin for each individual muscle fiber and multiple membrane intensity parameters (mean, maximum, quantiles per fiber were calculated. A histogram can depict the distribution of dystrophin intensities for the fiber population in the biopsy. This method was tested by measuring dystrophin in DMD, Becker muscular dystrophy, and healthy muscle samples. Analysis of duplicate or quadruplicate sections of DMD biopsies on the same or multiple days, by different operators, or using different antibodies, was shown to be objective and reproducible (inter-assay precision, CV 2-17% and intra-assay precision, CV 2-10%. Moreover, the method was sufficiently sensitive to detect consistently small differences in dystrophin between two biopsies from a patient with DMD before and after treatment with an investigational compound.

  13. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    Science.gov (United States)

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or 50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  14. [Comparison of the performance of the ECLusys anti-HCV reagent with the Lumipulse f and HISCL 2000-i HCVAb assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-09-01

    We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.

  15. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    Science.gov (United States)

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of

  16. Factors associated with the performance of a blood-based interferon-γ release assay in diagnosing tuberculosis.

    Directory of Open Access Journals (Sweden)

    Sally Banfield

    Full Text Available BACKGROUND: Indeterminate results are a recognised limitation of interferon-γ release assays (IGRA in the diagnosis of latent tuberculosis (TB infection (LTBI and TB disease, especially in children. We investigated whether age and common co-morbidities were associated with IGRA performance in an unselected cohort of resettled refugees. METHODS: A retrospective cross-sectional study of refugees presenting for their post-resettlement health assessment during 2006 and 2007. Refugees were investigated for prevalent infectious diseases, including TB, and for common nutritional deficiencies and haematological abnormalities as part of standard clinical screening protocols. Tuberculosis screening was performed by IGRA; QuantiFERON-TB Gold in 2006 and QuantiFERON-TBGold In-Tube in 2007. RESULTS: Complete data were available on 1130 refugees, of whom 573 (51% were children less than 17 years and 1041 (92% were from sub-Saharan Africa. All individuals were HIV negative. A definitive IGRA result was obtained in 1004 (89% refugees, 264 (26% of which were positive; 256 (97% had LTBI and 8 (3% had TB disease. An indeterminate IGRA result was obtained in 126 (11% refugees (all failed positive mitogen control. In multivariate analysis, younger age (linear OR= 0.93 [95% CI 0.91-0.95], P<0.001, iron deficiency anaemia (2.69 [1.51-4.80], P = 0.001, malaria infection (3.04 [1.51-6.09], P = 0.002, and helminth infection (2.26 [1.48-3.46], P<0.001, but not vitamin D deficiency or insufficiency, were associated with an indeterminate IGRA result. CONCLUSIONS: Younger age and a number of common co-morbidities are significantly and independently associated with indeterminate IGRA results in resettled predominantly African refugees.

  17. Radiation protection - Performance criteria for laboratories performing cytogenetic triage for assessment of mass casualties in radiological or nuclear emergencies - General principles and application to dicentric assay

    International Nuclear Information System (INIS)

    2008-01-01

    The potential for nuclear and radiological emergencies involving mass casualties from accidental or malicious acts or terrorism requires generic procedures for emergency dose assessment to help the development of medical response capabilities. A mass-casualties incident is defined here as an event that exceeds the local medical resources. Biological dosimetry, based on cytogenetic analysis using the dicentric assay, typically applied for accidental dose assessment, has been defined in ISO 19238. Cytogenetic triage is the use of chromosome damage to evaluate and assess approximately and rapidly radiation doses received by individuals in order to supplement the clinical categorization of casualties. This International Standard focuses on the use of the dicentric assay for rapid cytogenetic triage involving mass-casualty incidents. The primary purpose of this International Standard is to provide a guideline to all laboratories in order to perform the dicentric-bioassay - cytogenetic triage for dose assessment using documented and validated procedures. Secondly, it can facilitate the application of cytogenetic biodosimetry networks to permit comparison of results obtained in different laboratories. Finally, it is expected that laboratories newly commissioned to carry out the cytogenetic triage conform to this International Standard in order to perform the triage reproducibly and accurately. This International Standard is written in the form of procedures to adopt for dicentric-bioassay - cytogenetic triage biological dosimetry for overexposures involving mass radiological casualties. The criteria required for such measurements usually depend on the application of the results: medical management when appropriate, radiation-protection management, record keeping and medical/legal requirements. For example, selected cases can be analysed to produce a more accurate evaluation of high partial-body exposure; secondly, doses can be estimated for persons exposed below the

  18. Padronização de ensaio imunoenzimático para pesquisa de anticorpos das classes IgM e IgG anti-Toxoplasma gondii e comparação com a técnica de imunofluorescência indireta Standardization of enzyme-linked immunosorbent assay ELISA to detect anti-Toxoplasma gondii IgM and IgG antibodies, and comparison with the indirect immunofluorescence technique

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Antunes Uchôa

    1999-12-01

    Full Text Available A sorologia tem sido o método de escolha para o diagnóstico da toxoplasmose. Devido a isto, padronizamos um ensaio imunoenzimático (ELISA e comparamos seus resultados com a técnica de imunofluorescência indireta (IFI. A técnica padronizada apresentou na pesquisa de IgG sensibilidade (S de 96,7% e especificidade (E de 75%, com valor de predição de positividade (VPP de 83,3% e de negatividade (VPN de 94,7%, com uma concordância ajustada (K de 73,5%. A IFI apresentou S de 83,8%, E de 79,1% com VPP de 83,8 % e VPN de 79,1% com K de 63%. A concordância bruta entre os dois testes (ELISA/IFI foi de 88,3% para pesquisa de IgG e de 81,5% para pesquisa de IgM, sendo o K de 70,8% para IgG e de 1,3% para IgM, sendo o índice de correlação (r de 0,556 para IgG e de -0,023 para IgM. Podemos concluir que a ELISA-IgG padronizada é indicada nos processos de triagem sorológica, sendo a ELISA-IgM desaconselhada uma vez que apresentou baixos índices de concordância ajustada com a técnica de referência, sugerindo pouca confiabilidade dos resultados.Serology has been the most popular method to diagnose toxoplasmosis. Accordingly, this study standardizes an enzyme-linked immunosorbent assay (ELISA and compares its results with the IFI technique. In the IgG detection test, the standardized technique presented a sensibility (S of 96.77%, a specificity (SP of 75%, with a positive predictive value (PPV of 83.33%, a negative predictive value (NPV of 94.74%, and an adjusted concordance (K of 73.50%. The IFI exhibited 83.87% for S, 79.16% for SP, 83.81% for PPV, 79.16% for NPV, and 63% for K. The rough concordance between these two tests (ELISA/IFI was 88.35% for the IgG detection test and 81.55% for the IgM detection test. K was 70.82% and 1.31% for IgG and IgM, respectively, the correlation index (r being 0.556 for IgG and -0.023 for IgM. We can conclude that standardized ELISA-IgG is indicated in serologic selection processes, whereas the ELISA-IgM is

  19. Segment and fit thresholding: a new method for image analysis applied to microarray and immunofluorescence data.

    Science.gov (United States)

    Ensink, Elliot; Sinha, Jessica; Sinha, Arkadeep; Tang, Huiyuan; Calderone, Heather M; Hostetter, Galen; Winter, Jordan; Cherba, David; Brand, Randall E; Allen, Peter J; Sempere, Lorenzo F; Haab, Brian B

    2015-10-06

    Experiments involving the high-throughput quantification of image data require algorithms for automation. A challenge in the development of such algorithms is to properly interpret signals over a broad range of image characteristics, without the need for manual adjustment of parameters. Here we present a new approach for locating signals in image data, called Segment and Fit Thresholding (SFT). The method assesses statistical characteristics of small segments of the image and determines the best-fit trends between the statistics. Based on the relationships, SFT identifies segments belonging to background regions; analyzes the background to determine optimal thresholds; and analyzes all segments to identify signal pixels. We optimized the initial settings for locating background and signal in antibody microarray and immunofluorescence data and found that SFT performed well over multiple, diverse image characteristics without readjustment of settings. When used for the automated analysis of multicolor, tissue-microarray images, SFT correctly found the overlap of markers with known subcellular localization, and it performed better than a fixed threshold and Otsu's method for selected images. SFT promises to advance the goal of full automation in image analysis.

  20. Selecting the correct weighting factors for linear and quadratic calibration curves with least-squares regression algorithm in bioanalytical LC-MS/MS assays and impacts of using incorrect weighting factors on curve stability, data quality, and assay performance.

    Science.gov (United States)

    Gu, Huidong; Liu, Guowen; Wang, Jian; Aubry, Anne-Françoise; Arnold, Mark E

    2014-09-16

    A simple procedure for selecting the correct weighting factors for linear and quadratic calibration curves with least-squares regression algorithm in bioanalytical LC-MS/MS assays is reported. The correct weighting factor is determined by the relationship between the standard deviation of instrument responses (σ) and the concentrations (x). The weighting factor of 1, 1/x, or 1/x(2) should be selected if, over the entire concentration range, σ is a constant, σ(2) is proportional to x, or σ is proportional to x, respectively. For the first time, we demonstrated with detailed scientific reasoning, solid historical data, and convincing justification that 1/x(2) should always be used as the weighting factor for all bioanalytical LC-MS/MS assays. The impacts of using incorrect weighting factors on curve stability, data quality, and assay performance were thoroughly investigated. It was found that the most stable curve could be obtained when the correct weighting factor was used, whereas other curves using incorrect weighting factors were unstable. It was also found that there was a very insignificant impact on the concentrations reported with calibration curves using incorrect weighting factors as the concentrations were always reported with the passing curves which actually overlapped with or were very close to the curves using the correct weighting factor. However, the use of incorrect weighting factors did impact the assay performance significantly. Finally, the difference between the weighting factors of 1/x(2) and 1/y(2) was discussed. All of the findings can be generalized and applied into other quantitative analysis techniques using calibration curves with weighted least-squares regression algorithm.

  1. Validation and application of a high-performance liquid chromatography--tandem mass spectrometry assay for mosapride in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Chidambara, J; Varma, D P

    2005-09-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Copyright (c) 2005 John Wiley & Sons, Ltd.

  2. Saccharification Performances of Miscanthus at the Pilot and Miniaturized Assay Scales: Genotype and Year Variabilities According to the Biomass Composition

    Directory of Open Access Journals (Sweden)

    Nassim Belmokhtar

    2017-05-01

    Full Text Available HIGHLIGHTSBiomass production and cell wall composition are differentially impacted by harvesting year and genotypes, influencing then cellulose conversion in miniaturized assay.Using a high-throughput miniaturized and semi-automated method for performing the pretreatment and saccharification steps at laboratory scale allows for the assessment of these factors on the biomass potential for producing bioethanol before moving to the industrial scale.The large genetic diversity of the perennial grass miscanthus makes it suitable for producing cellulosic ethanol in biorefineries. The saccharification potential and year variability of five genotypes belonging to Miscanthus × giganteus and Miscanthus sinensis were explored using a miniaturized and semi-automated method, allowing the application of a hot water treatment followed by an enzymatic hydrolysis. The studied genotypes highlighted distinct cellulose conversion yields due to their distinct cell wall compositions. An inter-year comparison revealed significant variations in the biomass productivity and cell wall compositions. Compared to the recalcitrant genotypes, more digestible genotypes contained higher amounts of hemicellulosic carbohydrates and lower amounts of cellulose and lignin. In contrast to hemicellulosic carbohydrates, the relationships analysis between the biomass traits and cellulose conversion clearly showed the same negative effect of cellulose and lignin on cellulose digestion. The miniaturized and semi-automated method we developed was usable at the laboratory scale and was reliable for mimicking the saccharification at the pilot scale using a steam explosion pretreatment and enzymatic hydrolysis. Therefore, this miniaturized method will allow the reliable screening of many genotypes for saccharification potential. These findings provide valuable information and tools for breeders to create genotypes combining high yield, suitable biomass composition, and high saccharification

  3. Performance Evaluation of the VIDAS® Measles IgG Assay and Its Diagnostic Value for Measuring IgG Antibody Avidity in Measles Virus Infection

    Science.gov (United States)

    Dina, Julia; Creveuil, Christian; Gouarin, Stephanie; Viron, Florent; Hebert, Amelie; Freymuth, Francois; Vabret, Astrid

    2016-01-01

    The objective of this study is primarily to compare the performance of the VIDAS® Measles immunoglobulin (Ig)G assay to that of two other serological assays using an immunoassay technique, Enzygnost® Anti-measles Virus/IgG (Siemens) and Measles IgG CAPTURE EIA® (Microimmune). The sensitivity and the agreement of the VIDAS® Measles IgG assay compared to the Enzygnost® Anti-measles Virus/IgG assay and the Measles IgG CAPTURE EIA® assay are 100%, 97.2% and 99.0%, 98.4%, respectively. The very low number of negative sera for IgG antibodies does not allow calculation of specificity. As a secondary objective, we have evaluated the ability of the VIDAS® Measles IgG assay to measure anti-measles virus IgG antibody avidity with the help of the VIDAS® CMV IgG Avidity reagent, using 76 sera from subjects with measles and 238 other sera. Different groups of populations were analyzed. In the primary infection measles group, the mean IgG avidity index was 0.16 (range of 0.07 to 0.93) compared to 0.79 (range of 0.25 to 1) in the serum group positive for IgG antibodies and negative for IgM. These data allow to define a weak anti-measles virus IgG antibody avidity as an avidity index (AI) 0.6. The VIDAS® Measles IgG assay has a performance equivalent to that of other available products. Its use, individual and quick, is well adapted to testing for anti-measles immunity in exposed subjects. PMID:27556477

  4. A quantum dot-immunofluorescent labeling method to investigate the interactions between a crinivirus and its whitefly vector

    Directory of Open Access Journals (Sweden)

    James C. K. Ng

    2013-04-01

    Full Text Available Successful vector-mediated plant virus transmission entails an intricate but poorly understood interplay of interactions among virus, vector, and plant. The complexity of interactions requires continually improving/evaluating tools and methods for investigating the determinants that are central to mediating virus transmission. A recent study using an organic fluorophore (Alexa Fluor-based immunofluorescent localization assay demonstrated that specific retention of Lettuce infectious yellows virus (LIYV virions in the anterior foregut or cibarium of its whitefly vector is required for virus transmission. Continuous exposure of organic fluorophore to high excitation light intensity can result in diminished or loss of signals, potentially confounding the identification of important interactions associated with virus transmission. This limitation can be circumvented by incorporation of photostable fluorescent nanocrystals, such as quantum dots (QDs, into the assay. We have developed and evaluated a QD-immunofluorescent labeling method for the in vitro and in situ localization of LIYV virions based on the recognition specificity of streptavidin-conjugated QD605 (S-QD605 for biotin-conjugated anti-LIYV IgG (B-αIgG. IgG biotinylation was verified in a blot overlay assay by probing SDS-PAGE separated B-αIgG with S-QD605. Immunoblot analyses of LIYV using B-αIgG and S-QD605 resulted in a virus detection limit comparable to that of DAS-ELISA. In membrane feeding experiments, QD signals were observed in the anterior foregut or cibarium of virion-fed whitefly vectors but absent in those of virion-fed whitefly non-vectors. Specific virion retention in whitefly vectors corresponded with successful virus transmission. A fluorescence photobleaching assay of viruliferous whiteflies fed B-αIgG and S-QD605 vs. those fed anti-LIYV IgG and Alexa Fluor 488-conjugated IgG revealed that QD signal was stable and deteriorated ∼7 to 8 fold slower than that of Alexa

  5. Dual Testing Algorithm of BED-CEIA and AxSYM Avidity Index Assays Performs Best in Identifying Recent HIV Infection in a Sample of Rwandan Sex Workers

    NARCIS (Netherlands)

    Braunstein, Sarah L.; Nash, Denis; Kim, Andrea A.; Ford, Ken; Mwambarangwe, Lambert; Ingabire, Chantal M.; Vyankandondera, Joseph; van de Wijgert, Janneke H. H. M.

    2011-01-01

    To assess the performance of BED-CEIA (BED) and AxSYM Avidity Index (Ax-AI) assays in estimating HIV incidence among female sex workers (FSW) in Kigali, Rwanda. Eight hundred FSW of unknown HIV status were HIV tested; HIV-positive women had BED and Ax-AI testing at baseline and ≥12 months later to

  6. Comparison of the analytical and clinical performances of Abbott RealTime High Risk HPV, Hybrid Capture 2, and DNA Chip assays in gynecology patients.

    Science.gov (United States)

    Park, Seungman; Kang, Youjin; Kim, Dong Geun; Kim, Eui-Chong; Park, Sung Sup; Seong, Moon-Woo

    2013-08-01

    The detection of high-risk (HR) HPV in cervical cancer screening is important for early diagnosis of cervical cancer or pre-cancerous lesions. We evaluated the analytical and clinical performances of 3 HR HPV assays in Gynecology patients. A total of 991 specimens were included in this study: 787 specimens for use with a Hybrid Capture 2 (HC2) and 204 specimens for a HPV DNA microarray (DNA Chip). All specimens were tested using an Abbott RealTime High Risk HPV assay (Real-time HR), PGMY PCR, and sequence analysis. Clinical sensitivities for severe abnormal cytology (severe than high-grade squamous intraepithelial lesion) were 81.8% for Real-time HR, 77.3% for HC2, and 66.7% for DNA Chip, and clinical sensitivities for severe abnormal histology (cervical intraepithelial neoplasia grade 2+) were 91.7% for HC2, 87.5% for Real-time HR, and 73.3% for DNA Chip. As compared to results of the sequence analysis, HC2, Real-time HR, and DNA Chip showed concordance rates of 94.3% (115/122), 90.0% (117/130), and 61.5% (16/26), respectively. The HC2 assay and Real-time HR assay showed comparable results to each other in both clinical and analytical performances, while the DNA Chip assay showed poor clinical and analytical performances. The Real-time HR assay can be a good alternative option for HR HPV testing with advantages of allowing full automation and simultaneous genotyping of HR types 16 and 18. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Modification of the BAX System PCR assay for detecting Salmonella in beef, produce, and soy protein isolate. Performance Tested Method 100201.

    Science.gov (United States)

    Peng, Linda X; Wallace, Morgan; Andaloro, Bridget; Fallon, Dawn; Fleck, Lois; Delduco, Dan; Tice, George

    2011-01-01

    The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.

  8. Ultra-performance liquid chromatography-tandem mass spectrometry-based multiplex enzyme assay for six enzymes associated with hereditary hemolytic anemia.

    Science.gov (United States)

    Park, Chul Min; Lee, Kyunghoon; Jun, Sun-Hee; Song, Sang Hoon; Song, Junghan

    2017-08-15

    Deficiencies in erythrocyte metabolic enzymes are associated with hereditary hemolytic anemia. Here, we report the development of a novel multiplex enzyme assay for six major enzymes, namely glucose-6-phosphate dehydrogenase, pyruvate kinase, pyrimidine 5'-nucleotidase, hexokinase, triosephosphate isomerase, and adenosine deaminase, deficiencies in which are implicated in erythrocyte enzymopathies. To overcome the drawbacks of traditional spectrophotometric enzyme assays, the present assay was based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The products of the six enzymes were directly measured by using ion pairing UPLC-MS/MS, and the precision, linearity, ion suppression, optimal sample amounts, and incubation times were evaluated. Eighty-three normal individuals and 13 patients with suspected enzymopathy were analyzed. The UPLC running time was within 5min. No ion suppression was observed at the retention time for the products or internal standards. We selected an optimal dilution factor and incubation time for each enzyme system. The intra- and inter-assay imprecision values (CVs) were 2.5-12.1% and 2.9-14.3%, respectively. The linearity of each system was good, with R 2 values >0.97. Patient samples showed consistently lower enzyme activities than those from normal individuals. The present ion paring UPLC-MS/MS assay enables facile and reproducible multiplex evaluation of the activity of enzymes implicated in enzymopathy-associated hemolytic anemia. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott RealTime HCV Genotype II assay for hepatitis C genotyping.

    Science.gov (United States)

    Sridhar, Siddharth; Yip, Cyril C Y; Chan, Jasper F W; To, Kelvin K W; Cheng, Vincent C C; Yuen, Kwok-Yung

    2018-05-01

    The Abbott RealTime HCV Genotype II assay (Abbott-RT-HCV assay) is a real-time PCR based genotyping method for hepatitis C virus (HCV). This study measured the impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott-RT-HCV assay. 517 samples were genotyped using the Abbott-RT-HCV assay over a one-year period, 34 (6.6%) were identified as HCV genotype 1 without further subtype designation raising the possibility of inaccurate genotyping. These samples were subjected to confirmatory sequencing. 27 of these 34 (79%) samples were genotype 1b while five (15%) were genotype 6. One HCV isolate was an inter-genotypic 1a/4o recombinant. This is a novel natural HCV recombinant that has never been reported. Inter-genotypic recombination and probe cross-reactivity can affect the accuracy of the Abbott-RT-HCV assay, both of which have significant implications on antiviral regimen choice. Confirmatory sequencing of ambiguous results is crucial for accurate genotyping. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination

    NARCIS (Netherlands)

    Anckaert, E.; Öktem, M.; Thies, A.; Cohen-Bacrie, M.; Daan, N. M P; Schiettecatte, J.; Müller, C.; Topcu, D.; Gröning, A.; Ternaux, F.; Engel, C.; Engelmann, S.; Milczynski, C.

    2016-01-01

    Objectives: Anti-Müllerian hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The

  11. Validation of commercially available sphingosine kinase 2 antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Heidi A. Neubauer

    2017-03-01

    Full Text Available Sphingosine kinase 2 (SK2 is a ubiquitously expressed lipid kinase that has important, albeit complex and poorly understood, roles in regulating cell survival and cell death. In addition to being able to promote cell cycle arrest and apoptosis under certain conditions, it has recently been shown that SK2 can promote neoplastic transformation and tumorigenesis in vivo. Therefore, well validated and reliable tools are required to study and better understand the true functions of SK2. Here, we compare two commercially available SK2 antibodies: a rabbit polyclonal antibody from Proteintech that recognizes amino acids 266-618 of human SK2a, and a rabbit polyclonal antibody from ECM Biosciences that recognizes amino acids 36-52 of human SK2a. We examine the performance of these antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence staining of endogenous SK2, using human HEK293 and HeLa cell lines, as well as mouse embryonic fibroblasts (MEFs. Furthermore, we assess the specificity of these antibodies to the target protein through the use of siRNA-mediated SK2 knockdown and SK2 knockout (Sphk2-/- MEFs. Our results demonstrate that the Proteintech anti-SK2 antibody reproducibly displayed superior sensitivity and selectivity towards SK2 in immunoblot analyses, while the ECM Biosciences anti-SK2 antibody was reproducibly superior for SK2 immunoprecipitation and detection by immunofluorescence staining. Notably, both antibodies produced non-specific bands and staining in the MEFs, which was not observed with the human cell lines. Therefore, we conclude that the Proteintech SK2 antibody is a valuable reagent for use in immunoblot analyses, and the ECM Biosciences SK2 antibody is a useful tool for SK2 immunoprecipitation and immunofluorescence staining, at least in the human cell lines employed in this study.

  12. Performance Characteristics of qPCR Assays Targeting Human- and Ruminant-Associated Bacteroidetes for Microbial Source Tracking across Sixteen Countries on Six Continents

    Science.gov (United States)

    2013-01-01

    Numerous quantitative PCR assays for microbial fecal source tracking (MST) have been developed and evaluated in recent years. Widespread application has been hindered by a lack of knowledge regarding the geographical stability and hence applicability of such methods beyond the regional level. This study assessed the performance of five previously reported quantitative PCR assays targeting human-, cattle-, or ruminant-associated Bacteroidetes populations on 280 human and animal fecal samples from 16 countries across six continents. The tested cattle-associated markers were shown to be ruminant-associated. The quantitative distributions of marker concentrations in target and nontarget samples proved to be essential for the assessment of assay performance and were used to establish a new metric for quantitative source-specificity. In general, this study demonstrates that stable target populations required for marker-based MST occur around the globe. Ruminant-associated marker concentrations were strongly correlated with total intestinal Bacteroidetes populations and with each other, indicating that the detected ruminant-associated populations seem to be part of the intestinal core microbiome of ruminants worldwide. Consequently tested ruminant-targeted assays appear to be suitable quantitative MST tools beyond the regional level while the targeted human-associated populations seem to be less prevalent and stable, suggesting potential for improvements in human-targeted methods. PMID:23755882

  13. Use of commercially available rabbit monoclonal antibodies for immunofluorescence double staining

    DEFF Research Database (Denmark)

    Bzorek, M.; Stamp, I.M.; Frederiksen, L.

    2008-01-01

    Immunohistochemistry, that is, the use of polyclonal and monoclonal antibodies to detect cell and tissue antigens at a microscopical level is a powerful tool for both research and diagnostic purposes. Especially in the field of hematologic disease, there is often a need to detect several antigens...... synchronously, and we report here a fast and easy technique for demonstrating more than 1 antigen in 1 slide using immunofluorescence. We have used commercially available rabbit monoclonal antibodies (Cyclin D1, CD3, CD5, CD23, etc.) paired with mouse monoclonal antibodies (CD7, CD20, CD79a, Pax-5, etc.......) for double immunofluorescence labeling on paraffin-embedded tissue sections. Commercially available rabbit monoclonal antibodies in combination with mouse monoclonal antibodies proved useful in double immunofluorescence labeling on paraffin-embedded tissue, and all combinations used yielded excellent results...

  14. Hybrid Capture 2 and cobas human papillomavirus assays perform similarly on SurePath samples from women with abnormalities

    DEFF Research Database (Denmark)

    Fornari, D; Rebolj, M; Bjerregaard, B

    2016-01-01

    OBJECTIVE: In two laboratories (Departments of Pathology, Copenhagen University Hospitals of Herlev and Hvidovre), we compared cobas and Hybrid Capture 2 (HC2) human papillomavirus (HPV) assays using SurePath® samples from women with atypical squamous cells of undetermined significance (ASCUS......) at ≥30 years and women after treatment of cervical intraepithelial neoplasia (CIN). METHODS: Samples from 566 women with ASCUS and 411 women after treatment were routinely tested with HC2 and, thereafter, with cobas. Histological outcomes were retrieved from the Danish Pathology Data Base. We calculated...... the overall agreement between the assays, and compared their sensitivity and specificity for ≥CIN2. RESULTS: In women with ASCUS, HC2 and cobas testing results were similar in the two laboratories. The overall agreement was 91% (95% CI, 88-93). After CIN treatment, the overall agreement was 87% (95% CI, 82...

  15. Improved detection of Pneumocystis carinii by an immunofluorescence technique using monoclonal antibodies

    DEFF Research Database (Denmark)

    Orholm, M; Holten-Andersen, W; Lundgren, Jens Dilling

    1990-01-01

    To assess whether a recently developed indirect immunofluorescent stain using monoclonal antibodies was more sensitive in detecting Pneumocystis carinii than the combination of Giemsa and methenamine silver nitrate stains which has routinely been used in the laboratory, 88 lavage fluid specimens...... silver nitrate and toluidine blue O. Immunofluorescence using the monoclonal antibodies from the NIH was significantly more sensitive than any other single staining method and than the combination of Giemsa and methenamine silver nitrate staining. The study also showed that the cytospin centrifuge...

  16. Desempeño de la prueba de inmunofluorescencia directa en el diagnóstico del virus Influenza A(H1N1) Direct immunofluorescence assay performance in diagnosis of the Influenza A(H1N1) virus

    OpenAIRE

    Luis Pianciola; Gladys González; Melina Mazzeo; Mariano Navello; Natalia Quidel; María Fernanda Bulgheroni

    2010-01-01

    El 25 de abril de 2009, a menos de un mes de la detección en México del primer humano con virus Influenza A(H1N1), la enfermedad ya se había propagado a más de 40 países superando los 10 000 casos notificados. Dada su naturaleza impredecible, este tipo de virus requiere métodos diagnósticos apropiados, confiables y seguros, pero que también estén al alcance de los laboratorios clínicos. Mediante el estudio de 291 muestras de pacientes con sospecha de infección por virus Influenza A(H1N1) en N...

  17. Optimization of Single- and Dual-Color Immunofluorescence Protocols for Formalin-Fixed, Paraffin-Embedded Archival Tissues.

    Science.gov (United States)

    Kajimura, Junko; Ito, Reiko; Manley, Nancy R; Hale, Laura P

    2016-02-01

    Performance of immunofluorescence staining on archival formalin-fixed paraffin-embedded human tissues is generally not considered to be feasible, primarily due to problems with tissue quality and autofluorescence. We report the development and application of procedures that allowed for the study of a unique archive of thymus tissues derived from autopsies of individuals exposed to atomic bomb radiation in Hiroshima, Japan in 1945. Multiple independent treatments were used to minimize autofluorescence and maximize fluorescent antibody signals. Treatments with NH3/EtOH and Sudan Black B were particularly useful in decreasing autofluorescent moieties present in the tissue. Deconvolution microscopy was used to further enhance the signal-to-noise ratios. Together, these techniques provide high-quality single- and dual-color fluorescent images with low background and high contrast from paraffin blocks of thymus tissue that were prepared up to 60 years ago. The resulting high-quality images allow the application of a variety of image analyses to thymus tissues that previously were not accessible. Whereas the procedures presented remain to be tested for other tissue types and archival conditions, the approach described may facilitate greater utilization of older paraffin block archives for modern immunofluorescence studies. © 2016 The Histochemical Society.

  18. Detection of enteropathogens associated with travelers’ diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards

    Science.gov (United States)

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-01-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151

  19. Detection of enteropathogens associated with travelers' diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards.

    Science.gov (United States)

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-09-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman(™) FTA Elute cards smeared with stool containing pathogens associated with travelers' diarrhea. LoDs ranged from 10(2) to 10(5)CFU, PFU, or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoDs increased with prolonged storage of cards. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Performance characteristics of CA 19-9 radioimmunoassay and clinical significance of serum CA 19-9 assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, S.E.; Shong, Y.K.; Cho, B.Y.; Kim, N.K.; Koh, C.S.; Lee, M.H.; Hong, K.S.

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. (Author)

  1. Binding of 3H-iloprost to rat gastric mucosa: a pitfall in performing radioligand binding assays

    International Nuclear Information System (INIS)

    Beinborn, M.; Kromer, W.; Staar, U.; Sewing, K.F.

    1985-01-01

    Binding of 3 H-iloprost was studied in a 20,000 x g sediment of the rat gastric mucosa. When pH in both test tubes for total and non-specific binding was kept identical, no displaceable binding of iloprost could be detected. When no care was taken to keep the pH identical in corresponding test tubes of the binding assay, changes in pH simulated specific and displaceable binding of iloprost. Therefore it is concluded that - in contrast to earlier reports - it is not possible to demonstrate specific iloprost binding using the given method

  2. Method and apparatus for purifying nucleic acids and performing polymerase chain reaction assays using an immiscible fluid

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan; Light, Yooli Kim; Piccini, Matthew Ernest; Singh, Anup K.

    2017-10-31

    Embodiments of the present invention are directed toward devices, systems, and methods for purifying nucleic acids to conduct polymerase chain reaction (PCR) assays. In one example, a method includes generating complexes of silica beads and nucleic acids in a lysis buffer, transporting the complexes through an immiscible fluid to remove interfering compounds from the complexes, further transporting the complexes into a density medium containing components required for PCR where the nucleic acids disassociate from the silica beads, and thermocycling the contents of the density medium to achieve PCR. Signal may be detected from labeling agents in the components required for PCR.

  3. Radiometric measurements on the fabrication of non-destructive assay standards for WIPP-Performance Demonstration Program

    International Nuclear Information System (INIS)

    Wong, A.S.; Marshall, R.S.

    1997-04-01

    The Inorganic Elemental Analysis Group of LANL has prepared several different sets of working reference materials (WRMs). These WRMs are prepared by blending quantities of nuclear materials (plutonium, americium, and enriched uranium) with diatomaceous earth. The blends are encapsulated in stainless steel cylinders. These WRMs are being measured as blind controls in neutron and gamma based non-destructive assay (NDA) instruments. Radiometric measurements on the blending homogeneity and verification on a set of sixty three plutonium based WRMs are discussed in this paper

  4. Performance evaluation of four type-specific commercial assays for detection of herpes simplex virus type 1 antibodies in a Middle East and North Africa population.

    Science.gov (United States)

    Aldisi, Rana S; Elsidiq, Malaz S; Dargham, Soha R; Sahara, Afifah S; Al-Absi, Enas S; Nofal, Mariam Y; Mohammed, Layla I; Abu-Raddad, Laith J; Nasrallah, Gheyath K

    2018-03-22

    The number of diagnostic assays for the detection of herpes simplex virus type 1 (HSV-1) antibodies has increased over the years. However, their performance characteristics could vary among global populations. To investigate performance of two commercial ELISA kits, HerpeSelect ® 1 ELISA and Euroimmun Anti-HSV-1 (gC1) ELISA (IgG); and two commercial immunoblot (IB)/Western blot (WB) assays, HerpeSelect ® 1 and 2 Immunoblot IgG, and Euroimmun Anti-HSV-1/HSV-2 gG2 Euroline-WB (IgG/IgM); in detecting HSV-1 antibodies in a Middle East and North Africa (MENA) population. Blood specimens were collected from blood donors in Doha, Qatar, June 2013-2016. Twenty specimens were randomly selected from 10 MENA nationalities (Egypt, Iran, Jordan, Lebanon, Pakistan, Palestine, Qatar, Sudan, Syria, and Yemen; total = 200), and tested for HSV-1 antibodies. Across all six comparisons between assays, positive percent agreement ranged between 95.7% (95% CI: 91.4-98.3%) and 100.0% (95% CI: 97.8-100.0%). Negative percent agreement ranged between 86.2% (95% CI: 68.3-96.1%) and 96.2% (95% CI: 80.4-99.9%). Overall percent agreement ranged between 95.7% (95% CI: 91.7-97.8%) and 99.4% (95% CI: 96.7-99.9%). Cohen's kappa statistic ranged between 0.84 (95% CI: 0.73-0.95) and 0.98 (95% CI: 0.93-1.00). Compared against IB/WB, HerpeSelect ® and Euroimmun had sensitivities and specificities >96% and >86%, respectively. Positive and negative predictive values were >97% and >83%, respectively. The assays showed excellent concordance with one another, and with a high kappa statistic. The ELISA kits demonstrated robust diagnostic performance compared to the IB/WB assays. These findings support the assays' utility in clinical diagnosis and research in MENA populations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. BLIND TRIALS EVALUATING IN VITRO INFECTIVITY OF CRYPTOSPORIDIUM PARVUM OOCYSTS USING CELL CULTURE IMMUNOFLUORESCENCE

    Science.gov (United States)

    An optimized cell culture-immunofluorescence (IFA) procedure, using the HCT-8 cell line, was evaluated in 'blind' trials to determine the sensitivity and reproducibility for measuring infectivity of flow cytometry prepared inocula of C. parvum oocysts. In separate trials, suspens...

  6. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    Science.gov (United States)

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  7. Genetic mouse embryo assay: improving performance and quality testing for assisted reproductive technology (ART) with a functional bioassay.

    Science.gov (United States)

    Gilbert, Rebecca S; Nunez, Brandy; Sakurai, Kumi; Fielder, Thomas; Ni, Hsiao-Tzu

    2016-03-24

    Growing concerns about safety of ART on human gametes, embryos, clinical outcomes and long-term health of offspring require improved methods of risk assessment to provide functionally relevant assays for quality control testing and pre-clinical studies prior to clinical implementation. The one-cell mouse embryo assay (MEA) is the most widely used for development and quality testing of human ART products; however, concerns exist due to the insensitivity/variability of this bioassay which lacks standardization and involves subjective analysis by morphology alone rather than functional analysis of the developing embryos. We hypothesized that improvements to MEA by the use of functional molecular biomarkers could enhance sensitivity and improve detection of suboptimal materials/conditions. Fresh one-cell transgenic mouse embryos with green fluorescent protein (GFP) expression driven by Pou6f1 or Cdx2 control elements were harvested and cultured to blastocysts in varied test and control conditions to compare assessment by standard morphology alone versus the added dynamic expression of GFP for screening and selection of critical raw materials and detection of suboptimal culture conditions. Transgenic mouse embryos expressing functionally relevant biomarkers of normal early embryo development can be used to monitor the developmental impact of culture conditions. This novel approach provides a superior MEA that is more meaningful and sensitive for detection of embryotoxicity than morphological assessment alone.

  8. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    Science.gov (United States)

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  9. The impact of HIV infection and CD4 cell count on the performance of an interferon gamma release assay in patients with pulmonary tuberculosis

    DEFF Research Database (Denmark)

    Aabye, Martine G.; Ravn, Pernille; PrayGod, George

    2009-01-01

    pulmonary tuberculosis (PTB) in a TB- and HIV-endemic population and the effect of HIV-infection and CD4 cell count on test performance. METHODOLOGY/PRINCIPAL FINDINGS: 161 patients with sputum culture confirmed PTB were subjected to HIV- and QFT-IT testing and measurement of CD4 cell count. The QFT......BACKGROUND: The performance of the tuberculosis specific Interferon Gamma Release Assays (IGRAs) has not been sufficiently documented in tuberculosis- and HIV-endemic settings. This study evaluated the sensitivity of the QuantiFERON TB-Gold In-Tube (QFT-IT) in patients with culture confirmed...

  10. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    Science.gov (United States)

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  11. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  12. Evaluation of the performance of two tuberculosis interferon gamma release assays (IGRA-ELISA and T-SPOT.TB) for diagnosing Mycobacterium tuberculosis infection.

    Science.gov (United States)

    Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei

    2018-04-01

    The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. DETECTION OF ANTIBODIES TO CANDIDA ALBICANS GERM TUBE BY IMMUNOFLUORESCENCE IN IMMUNOSUPPRESSED MICE WITH EXPERIMENTAL SYSTEMIC CANDIDIASIS

    Directory of Open Access Journals (Sweden)

    F. Zaini

    2007-07-01

    Full Text Available "nThe increasing incidence of systemic candidiasis, which parallels the use of invasive and immunosuppressive medical procedures, necessitates development of rapid and cost effective tests for diagnosis of systemic candidiasis. Therefore in this study 85 mice were first immunosuppressed by cyclophosphamide and then infected by Candida albicans NCPF 3153. Other 85 mice were employed as control. The case and control mice were bled and then autopsied. Hearts and kidneys were checked by direct, histopathological and cultural examination for systemic candidiasis. The 85 sera from histological proven cases and 85 control mice were adsorbed with heat killed blastospores of same strain of C. albicans. Anti-Candida albicans germ tube antibodies were detected by indirect immunofluorescence assay for diagnosis of invasive candidiasis in case and control mice. In addition, sera from 35 mice with proven cryptococcosis were also tested. While 84 mice with proven systemic candidiasis (100% had anti-germ tube antibodies, these antibodies were absent in all controls and mice with cryptococcosis. The specificity was 100%, indicating a high degree of discrimination was possible between systemic candidiasis and cryptococcosis in the mice studied. It must be concluded that anti-germ tube responses did not appear to be significantly reduced in immunocompromised mice.

  14. Validation of Performance of the Gen-Probe Human Immunodeficiency Virus Type 1 Viral Load Assay with Genital Swabs and Breast Milk Samples

    Science.gov (United States)

    DeVange Panteleeff, Dana; Emery, Sandra; Richardson, Barbra A.; Rousseau, Christine; Benki, Sarah; Bodrug, Sharon; Kreiss, Joan K.; Overbaugh, Julie

    2002-01-01

    Human immunodeficiency type 1 (HIV-1) continues to spread at an alarming rate. The virus may be transmitted through blood, genital secretions, and breast milk, and higher levels of systemic virus in the index case, as measured by plasma RNA viral load, have been shown to correlate with increased risk of transmitting HIV-1 both vertically and sexually. Less is known about the correlation between transmission and HIV-1 levels in breast milk or genital secretions, in part because reliable quantitative assays to detect HIV-1 in these fluids are not available. Here we show that the Gen-Probe HIV-1 viral load assay can be used to accurately quantify viral load in expressed breast milk and in cervical and vaginal samples collected on swabs. Virus could be quantified from breast milk and swab samples spiked with known amounts of virus, including HIV-1 subtypes A, C, and D. As few as 10 copies of HIV-1 RNA could be detected above background threshold levels in ≥77% of assays performed with spiked breast milk supernatants and mock swabs. In genital swab samples from HIV-1-infected women, similar levels of HIV-1 RNA were consistently detected in duplicate swabs taken from the same woman on the same clinic visit, suggesting that the RNA values from a single swab sample can be used to measure genital viral load. PMID:12409354

  15. Use of activity-based probes to develop high throughput screening assays that can be performed in complex cell extracts.

    Directory of Open Access Journals (Sweden)

    Edgar Deu

    2010-08-01

    Full Text Available High throughput screening (HTS is one of the primary tools used to identify novel enzyme inhibitors. However, its applicability is generally restricted to targets that can either be expressed recombinantly or purified in large quantities.Here, we described a method to use activity-based probes (ABPs to identify substrates that are sufficiently selective to allow HTS in complex biological samples. Because ABPs label their target enzymes through the formation of a permanent covalent bond, we can correlate labeling of target enzymes in a complex mixture with inhibition of turnover of a substrate in that same mixture. Thus, substrate specificity can be determined and substrates with sufficiently high selectivity for HTS can be identified. In this study, we demonstrate this method by using an ABP for dipeptidyl aminopeptidases to identify (Pro-Arg2-Rhodamine as a specific substrate for DPAP1 in Plasmodium falciparum lysates and Cathepsin C in rat liver extracts. We then used this substrate to develop highly sensitive HTS assays (Z'>0.8 that are suitable for use in screening large collections of small molecules (i.e >300,000 for inhibitors of these proteases. Finally, we demonstrate that it is possible to use broad-spectrum ABPs to identify target-specific substrates.We believe that this approach will have value for many enzymatic systems where access to large amounts of active enzyme is problematic.

  16. Comparison of Assays for Sensitive and Reproducible Detection of Cell Culture-Infectious Cryptosporidium parvum and Cryptosporidium hominis in Drinking Water

    Science.gov (United States)

    Di Giovanni, George D.; Rochelle, Paul A.

    2012-01-01

    This study compared the three most commonly used assays for detecting Cryptosporidium sp. infections in cell culture: immunofluorescent antibody and microscopy assay (IFA), PCR targeting Cryptosporidium sp.-specific DNA, and reverse transcriptase PCR (RT-PCR) targeting Cryptosporidium sp.-specific mRNA. Monolayers of HCT-8 cells, grown in 8-well chamber slides or 96-well plates, were inoculated with a variety of viable and inactivated oocysts to assess assay performance. All assays detected infection with low doses of flow cytometry-enumerated Cryptosporidium parvum oocysts, including infection with one oocyst and three oocysts. All methods also detected infection with Cryptosporidium hominis. The RT-PCR assay, IFA, and PCR assay detected infection in 23%, 25%, and 51% of monolayers inoculated with three C. parvum oocysts and 10%, 9%, and 16% of monolayers inoculated with one oocyst, respectively. The PCR assay was the most sensitive, but it had the highest frequency of false positives with mock-infected cells and inactivated oocysts. IFA was the only infection detection assay that did not produce false positives with mock-infected monolayers. IFA was also the only assay that detected infections in all experiments with spiked oocysts recovered from Envirochek capsules following filtration of 1,000 liters of treated water. Consequently, cell culture with IFA detection is the most appropriate method for routine and sensitive detection of infectious Cryptosporidium parvum and Cryptosporidium hominis in drinking water. PMID:22038611

  17. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia.

    Science.gov (United States)

    Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2011-09-01

    Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. The diagnostic performance of a single GeneXpert MTB/RIF assay in an intensified tuberculosis case finding survey among HIV-infected prisoners in Malaysia.

    Directory of Open Access Journals (Sweden)

    Haider Abdulrazzaq Abed Al-Darraji

    Full Text Available Delays in tuberculosis (TB diagnosis, particularly in prisons, is associated with detrimental outcomes. The new GeneXpert MTB/RIF assay (Xpert offers accurate and rapid diagnosis of active TB, but its performance in improving case detection in high-transmission congregate settings has yet to be evaluated. We assessed the diagnostic accuracy of a single Xpert assay in an intensified case finding survey among HIV-infected prisoners in Malaysia.HIV-infected prisoners at a single site provided two early-morning sputum specimens to be examined using fluorescence smear microscopy, BACTEC MGIT 960 liquid culture and a single Xpert. The sensitivity, specificity, negative and positive predictive values of Xpert were calculated relative to gold-standard results using MGIT 960 liquid culture. Relevant clinical and demographic data were used to examine correlates of active TB disease.The majority of enrolled subjects with complete data (N=125 were men (90.4%, age <40 years (61.6% and had injected drugs (75.2%. Median CD4 lymphocyte count was 337 cells/µL (IQR 149-492; only 19 (15.2% were receiving antiretroviral therapy. Of 15 culture-positive TB cases, single Xpert assay accurately detected only eight previously undiagnosed TB cases, resulting in a sensitivity, specificity, positive predictive value and negative predictive value of 53.3% (95% CI 30.12-75.2%, 100% (95% CI 96.6-100%, 100% (95% CI 67.56-100% and 94.0% (95% CI 88.2-97.1%, respectively. Only 1 of 15 (6.7% active TB cases was smear-positive. The prevalence (12% of undiagnosed active pulmonary TB (15 of 125 prisoners was high and associated with longer duration of drug use (AOR 1.14, 95% CI 1.03-1.26, for each year of drug use.Single Xpert assay improved TB case detection and outperformed AFB smear microscopy, but yielded low screening sensitivity. Further examination of the impact of HIV infection on the diagnostic performance of the new assay alongside other screening methods in correctional

  19. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  20. Indirect micro-immunofluorescence test for detecting type-specific antibodies to herpes simplex virus.

    Science.gov (United States)

    Forsey, T; Darougar, S

    1980-02-01

    A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.

  1. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    Science.gov (United States)

    Zapata, M; Chernesky, M; Mahony, J

    1984-06-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  2. Indirect immunofluorescence staining of Chlamydia trachomatis inclusions in microculture plates with monoclonal antibodies.

    OpenAIRE

    Zapata, M; Chernesky, M; Mahony, J

    1984-01-01

    Indirect immunofluorescence (IF) staining, using a monoclonal antibody, detected two- to fourfold more inclusions than did iodine staining. Of 274 clinical specimens, 53 (19.3%) were positive by IF on passage 1 as compared with 33 (12%) by iodine staining (P less than 0.005). IF-stained inclusions in McCoy cells in the bottom of microculture wells were readily viewed with a long-focal-length objective at a magnification of 250 X.

  3. Immunofluorescent staining of nuclear antigen in lymphoid cells transformed by Herpesvirus papio (HVP).

    Science.gov (United States)

    Schmitz, H

    1981-01-01

    An improved fixation method for antigen detection in lymphoblastoid cells is described. Herpesvirus papio nuclear antigen (HUPNA) could be stained in several transformed lymphoid cell lines by anti-complement immunofluorescence (ACIF). Antibody to HUPNA was detected in many human sera containing antibodies to Epstein-Barr virus capsid and nuclear antigen (EBNA). Rheumatoid arthritis sera showed a high incidence of both anti-EBNA and anti-HUPNA antibodies.

  4. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  5. Assay system

    International Nuclear Information System (INIS)

    Patzke, J.B.; Rosenberg, B.J.

    1984-01-01

    The accuracy of assays for monitoring concentrations of basic drugs in biological fluids containing a 1 -acid glycoproteins, such as blood (serum or plasma), is improved by the addition of certain organic phosphate compounds to minimize the ''protein effect.'' Kits containing the elements of the invention are also disclosed

  6. Fibrinogen Demonstration in Oral Lichen Planus: An Immunofluorescence Study on Archival Tissues.

    Science.gov (United States)

    Shirol, Pallavi D; Naik, Veena; Kale, Alka

    2015-10-01

    Lichen planus is a premalignant condition with minimal diagnostic aids. This study is an attempt to use paraffin embedded sections of lichen planus with immunofluorescein stain and to evaluate the immunofluorescent sections to establish pattern of fibrinogen deposition. Thirty-five paraffin embedded sections of old and new cases of oral lichen planus (study group) and five normal oral mucosa (control group) were chosen. Two sections of each (H & E) case were taken, one was stained with hematoxylin and eosin and another with fluorescein isothiocynate conjugate (FITC) polyclonal rabbit antibody against fibrinogen. Fluorescent findings were examined with a fluorescent microscope. A high statistical significant correlation was found in respect to fluorescence positivity, intensity of fluorescence and distribution of fluorescence each with p < 0.0001 and fluorescence at blood vessel walls (p = 0.0003). This study suggested that paraffin embedded sections can be successfully used in direct immunofluorescence staining in routine set up where only formalin fixed tissues are received. Paraffin embedded sections can be successfully used in direct immunofluorescence staining when only formalin fixed tissues are received.

  7. Validated assay for the simultaneous quantification of total vincristine and actinomycin-D concentrations in human EDTA plasma and of vincristine concentrations in human plasma ultrafiltrate by high-performance liquid chromatography coupled with tandem mass spectrometry

    NARCIS (Netherlands)

    Damen, Carola W. N.; Israëls, Trijn; Caron, Huib N.; Schellens, Jan H. M.; Rosing, Hilde; Beijnen, Jos H.

    2009-01-01

    A sensitive, specific and efficient high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the simultaneous determination of total vincristine and actinomycin-D concentrations in human plasma and an assay for the determination of unbound vincristine are presented.

  8. A Unique Immunofluorescence Protocol to Detect Protein Expression in Vascular Tissues: Tacking a Long Standing Pathological Hitch

    Directory of Open Access Journals (Sweden)

    Puneet GANDHI

    2018-01-01

    Full Text Available Objective: Autofluorescence induced interference is one of the major drawbacks in immunofluorescence analysis of formalin-fixed paraffin-embedded tissues, as it decreases the signal-to-noise ratio of specific labeling. Apart from aldehyde-fixation induced artifacts; collagen and elastin, red blood cells and endogenous fluorescent pigment lipofuscin are prime sources of autofluorescence in vascular and aging tissues. We describe herein, an optimized indirect-immunofluorescence method for archival formalin-fixed paraffin-embedded tissues tissues and cryo sections, using a combination of 3-reagents in a specific order, to achieve optimal fluorescence signals and imaging. Material and Method: Human telomerase reverse transcriptase, a protein implicated as a proliferation marker, was chosen relevant to its expression in solid tumors along with 3 other intracellular proteins exhibiting nuclear and/or cytoplasmic expression. Staining was performed on 10 glioma tissue sections along with 5 of their cryo sections, 5 sections each of hepatocellular, lung, papillary-thyroid and renal cell carcinoma, with 10 non-malignant brain tissue samples serving as control. Specimens were imaged using epifluorescence microscopy, followed by software-based quantification of fluorescence signals for statistical analysis and validation. Results: We observed that the combined application of sodium-borohydride followed by crystal violet before antigen retrieval and a Sudan black B treatment after secondary antibody application proved to be most efficacious for masking autofluorescence/non-specific background in vascular tissues. Conclusion: This unique trio-methodology provides quantifiable observations with maximized fluorescence signal intensity of the target protein for longer retention time of the signal even after prolonged storage. The results can be extrapolated to other human tissues for different protein targets.

  9. Investigation of OMNIgene·SPUTUM performance in delayed tuberculosis testing by smear, culture, and Xpert MTB/RIF assays in Uganda

    Directory of Open Access Journals (Sweden)

    C.D. Kelly-Cirino

    2017-06-01

    Full Text Available OMNIgene·SPUTUM (OM-S is a sample transport reagent designed to work with all tuberculosis diagnostics while eliminating the need for cold chain. OM-S-treated sputum samples were assayed in several tests after multiday holds. Raw sputa from 100 patients underwent direct smear microscopy, were manually split and assigned to the OM-S group [OM-S added at collection (no other processing required and tested after 0- to 5-day holds at room temperature] or standard-of-care (SOC group (NaOH/N-acetyl l-cysteine decontamination, all tested on day of collection. Concentrated smear microscopy, Lowenstein Jensen (LJ culture, and mycobacteria growth indicator tube (MGIT culture were performed. For patients with negative direct smear, a second sample was split, with SOC (raw sputum and OM-S portions (sediment tested in the Xpert MTB/RIF (Xpert assay. OM-S group and SOC group results were strongly concordant on all four tests [range, 89% (MGIT–97% (Xpert]. OM-S MGIT, LJ, and Xpert tests were in statistical agreement with SOC MGIT as reference. OM-S specimens had lower culture contamination rates (3% vs. 10% LJ; 2% vs. 5% MGIT but required, on average, 5.6 additional days to become MGIT-positive. The findings suggest that samples held/transported in OM-S are compatible with smear microscopy, LJ or MGIT culture, and Xpert, and perform comparably to fresh sputum samples. Larger feasibility studies are warranted.

  10. Design of benign matrix drums for the non-destructive assay performance demonstration program for the National TRU Program

    International Nuclear Information System (INIS)

    Becker, G.K.

    1996-09-01

    Regulatory compliance programs associated with the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) require the collection of waste characterization data of known quality to support repository performance assessment, permitting, and associated activities. Blind audit samples, referred to as PDP (performance demonstration program) samples, are devices used in the NDA PDP program to acquire waste NDA system performance data per defined measurement routines. As defined under the current NDA PDP Program Plan, a PDP sample consists of a DOT 17C 55-gallon PDP matrix drum configured with insertable radioactive standards, working reference materials (WRMs). The particular manner in which the matrix drum and PDP standard(s) are combined is a function of the waste NDA system performance test objectives of a given cycle. The scope of this document is confined to the design of the PDP drum radioactive standard internal support structure, the matrix type and the as installed configuration. The term benign is used to designate a matrix possessing properties which are nominally non-interfering to waste NDA measurement techniques. Measurement interference sources are technique specific but include attributes such as: high matrix density, heterogeneous matrix distributions, matrix compositions containing high moderator/high Z element concentrations, etc. To the extent practicable the matrix drum design should not unduly bias one NDA modality over another due to the manner in which the matrix drum configuration manifests itself to the measurement system. To this end the PDP matrix drum configuration and composition detailed below is driven primarily by the intent to minimize the incorporation of matrix attributes known to interfere with fundamental waste NDA modalities, i.e. neutron and gamma based techniques

  11. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  12. Performance of the fully automated progesterone assays on the Abbott AxSYM and the Technicon Immuno 1 Analyser compared with the radioimmunoassay progesterone MAIA

    International Nuclear Information System (INIS)

    Reinsberg, J.; Jost, E.; Van der Ven, H.

    1997-01-01

    Test performance of two automated progesterone assays available on the immunoassay analysers Abbott AxSYM and Technicon Immuno 1, respectively, was evaluated in comparison with the radioimmunoassay Progesterone MAIA. For assessment of test performance imprecision, functional sensitivity and linearity of dilution was examined. Correlation with the manual radioimmunoassay was assessed using 122 serum samples over the range 0-110 nmol/L. Imprecision studies revealed for the AxSYM Progesterone within-run CV's of 1.8-6.4% and day-to-day CV's of 3.5-9.7% (concentration range 2.3-75 nmol/L); Immuno 1 Progesterone: within-run CV's 1.0-7.3%, day-to-day CV's 2.3-7.7% (concentration range 1.2-60 nmol/L). The functional sensitivity was <1.7 nmol/L for the AxSYM Progesterone and <1.1 nmol/L for the Immuno 1 Progesterone. With the AxSYM Progesterone the mean recovery after dilution from five samples was 102% (89-107%), from one sample only 69-80% was recovered; with the Immuno 1 Progesterone the mean recovery was 95% (80-105%). Despite of a quite good overall correlation (coefficients 0.972 and 0.981) the relationship of both assays to the Progesterone MAIA significantly deviate from linearity with a considerably higher slope within the lower concentration range. The relationship between the automated assays was linear over the entire concentration range (Immuno = 1.207 * AxSYM + 1; r = 0.986). The time to first result was 20 min for the AxSYM Progesterone, 45 min for the Immuno 1 Progesterone and 90 min for the Progesterone MAIA. The evaluated progesterone assays both exhibit an excellent precision and a high degree of sensitivity. They offer a rapid and flexible method for progesterone determination which may be especially useful for the monitoring of ovarian stimulation during in-vitro fertilization. (author)

  13. Evaluation of the HOOF-Print assay for typing Brucella abortus strains isolated from cattle in the United States: results with four performance criteria

    Directory of Open Access Journals (Sweden)

    Ewalt Darla R

    2005-06-01

    Full Text Available Abstract Background A fundamental question that arises during epidemiological investigations of bacterial disease outbreaks is whether the outbreak strain is genetically related to a proposed index strain. Highly discriminating genetic markers for characterizing bacterial strains can help in clarifying the genetic relationships among strains. Under the auspices of the European Society of Clinical Microbiology and Infectious Diseases, the European Study Group for Epidemiological Markers (ESGEM established guidelines for evaluating the performance of typing systems based of a number of criteria. Recently, HOOF-Print genotype analysis, a new method for typing Brucella abortus strains based on hypervariability at eight tandem repeat loci, was described. This paper evaluates the HOOF-Print assay by four of the criteria set out by the ESGEM: typeability, reproducibility, power of discrimination, and concordance with other typing methods. Results The HOOF-Print Assay was evaluated with a test population composed of 97 unrelated field isolates and 6 common laboratory strains of B. abortus. Both typeability and reproducibility of the assay were excellent. Allele diversity and frequency varied widely among the eight loci, ranging from 1 to 13 alleles. The power of discrimination, measured by the Hunter-Gaston discrimination index (HGDI, varied by locus ranging from 0 to 0.89, where a maximal value of 1.0 indicates discrimination of all strains. The HGDI values calculated for subgroups sorted by biovar were similar to the values determined for the whole population. None of the individual loci achieved the recommended HGDI threshold of 0.95, but the HGDI of the composite profiles was 0.99 (93 unique genotypes from 97 field strains evaluated, well above the recommended threshold. By comparison, the HGDI value for biovar typing was 0.61 in a test population biased with disproportionate numbers of the less common biovars. Cluster analysis based on HOOF

  14. Analytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer

    Directory of Open Access Journals (Sweden)

    Maki Sasano

    2017-08-01

    Full Text Available Background: Cyclosporine (CsA and tacrolimus (TAC are immunosuppressant drugs that are often used to treat autoimmune diseases and as transplantation therapy; therefore, their concentrations need to be monitored carefully. We herein evaluated the analytical performance of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assay kits, which have been newly developed to measure CsA and TAC concentrations in the whole blood. Methods: We used residual whole blood samples from autoimmune disease and transplantation patients who were being treated with CsA or TAC. CsA concentrations were measured using an affinity chrome-mediated immunoassay (ACMIA and an electrochemiluminescence immunoassay (ECLIA. TAC concentrations were measured using a chemiluminescence immunoassay (CLIA and ECLIA. We investigated assay precision, linearity, lower limit of quantitation (LOQ, stability of calibration, influence of interference substances and the hematocrit, correlation of ACMIA with ECLIA, and correlation of CLIA with ECLIA. Results: Within-assay coefficients of variation were 1.8−3.6% (CsA: 94−1238 ng/mL and 2.9−3.9% (TAC: 2.1−17.8 ng/mL, whereas day-to-day coefficients of variation ranged between 3.0−4.1% (CsA and 2.8−3.9% (TAC. The limits of quantitation were defined as the concentration at which the CV was approximately 10%. Each lower LOQ obtained was 16 ng/mL (CsA, and 0.95 ng/mL (TAC. CsA and TAC calibrations were stable for at least 21 days. Neither the presence of conjugated bilirubin, unconjugated bilirubin, chyle, and rheumatoid factor nor the hematocrit affected these assays. A method comparison using a standardized major axis regression analysis of ACMIA and ECLIA was r=0.995, y=0.924x −1.175, n=200 (CsA, while that of CLIA and ECLIA was r=0.994, y=1.080x −0.197, n=200 (TAC. Conclusions: The analytical performances of the Elecsys® Cyclosporine and Elecsys®Tacrolimus assays were acceptable

  15. Utility of a Multiplex PCR Assay for Detecting Herpesvirus DNA in Clinical Samples

    Science.gov (United States)

    Druce, Julian; Catton, Mike; Chibo, Doris; Minerds, Kirsty; Tyssen, David; Kostecki, Renata; Maskill, Bill; Leong-Shaw, Wendy; Gerrard, Marie; Birch, Chris

    2002-01-01

    A multiplex PCR was designed to amplify herpes simplex virus types 1 and 2, cytomegalovirus, and varicella-zoster virus DNA present in a diverse range of clinical material. The susceptibility of these viruses to in vivo inhibition by at least one antiviral drug was an important consideration in their inclusion in the multiplex detection system. An aliquot of equine herpesvirus was introduced into each specimen prior to extraction and served as an indicator of potential inhibitors of the PCR and a detector of suboptimal PCR conditions. Compared to virus isolation and immunofluorescence-based antigen detection, the multiplex assay yielded higher detection rates for all viruses represented in the assay. The turnaround time for performance of the assay was markedly reduced compared to those for the other techniques used to identify these viruses. More than 21,000 tests have been performed using the assay. Overall, the multiplex PCR enabled the detection of substantially increased numbers of herpesviruses, in some cases in specimens or anatomical sites where previously they were rarely if ever identified using traditional detection methods. PMID:11980951

  16. A multiplexed reverse transcriptase PCR assay for identification of viral respiratory pathogens at point-of-care

    Energy Technology Data Exchange (ETDEWEB)

    Letant, S E; .Ortiz, J I; Tammero, L; Birch, J M; Derlet, R W; Cohen, S; Manning, D; McBride, M T

    2007-04-11

    We have developed a nucleic acid-based assay that is rapid, sensitive, specific, and can be used for the simultaneous detection of 5 common human respiratory pathogens including influenza A, influenza B, parainfluenza type 1 and 3, respiratory syncytial virus, and adenovirus group B, C, and E. Typically, diagnosis on an un-extracted clinical sample can be provided in less than 3 hours, including sample collection, preparation, and processing, as well as data analysis. Such a multiplexed panel would enable rapid broad-spectrum pathogen testing on nasal swabs, and therefore allow implementation of infection control measures, and timely administration of antiviral therapies. This article presents a summary of the assay performance in terms of sensitivity and specificity. Limits of detection are provided for each targeted respiratory pathogen, and result comparisons are performed on clinical samples, our goal being to compare the sensitivity and specificity of the multiplexed assay to the combination of immunofluorescence and shell vial culture currently implemented at the UCDMC hospital. Overall, the use of the multiplexed RT-PCR assay reduced the rate of false negatives by 4% and reduced the rate of false positives by up to 10%. The assay correctly identified 99.3% of the clinical negatives, 97% of adenovirus, 95% of RSV, 92% of influenza B, and 77% of influenza A without any extraction performed on the clinical samples. The data also showed that extraction will be needed for parainfluenza virus, which was only identified correctly 24% of the time on un-extracted samples.

  17. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    Directory of Open Access Journals (Sweden)

    Maity Susmita

    2012-11-01

    Full Text Available Abstract Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.; ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd. gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd., Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd. did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100% except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.. The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p  Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for

  18. High-performance liquid chromatographic assay for acetaminophen and phenacetin in the presence of their metabolites in biological fluids

    International Nuclear Information System (INIS)

    Pang, K.S.; Taburet, A.M.; Hinson, J.A.; Gillette, J.R.

    1979-01-01

    The authors propose a method in which tracer amounts of a radiolabeled compound are used as the internal standard for the same unlabeled compound in high-performance liquid chromatography. The approach is valuable when a response from the internal standard becomes undesirable due to the presence of interference by the metabolites. The authors tested their approach with phenacetin and its metabolites, 2-hydroxyphenacetin, N-hydroxyphenacetin, phenetidine, acetaminophen sulfate conjugate and acetaminophen glucuronide conjugate in biological fluids with the use of [ 14 C] phenacetin and [ 3 H] acetaminophen as the internal standards, and were able to quantitate both phenacetin and acetaminophen simultaneously. They also tested the alternative approach in which the unlabeled drug was used as internal standard for tracer amounts of the same radiolabeled compound, with phenacetin and acetaminophen as the internal standards for tracer amounts of [ 14 C] phenacetin and [ 3 H] acetaminophen. Again, they were able to quantiate the two tracer radiolabeled compounds simultaneously. (Auth.)

  19. Development and validation of a chiral high-performance liquid chromatography assay for rogletimide and rogletimide-N-oxide isomers in plasma.

    Science.gov (United States)

    Etienne, M C; Oster, W; Milano, G

    1996-01-01

    The purpose of the present study was to develop and validate a stereo-specific high-performance liquid chromatography (HPLC) assay for rogletimide (Rog) and rogletimide-N-oxide (Nox) isomers in plasma. The assay was performed with a chiral cellulose-[4-methylbenzoate]ester column (Chiracel OJ). Optimal separation was achieved isocratically with a mobile phase consisting of n-hexane/anhydrous ethanol (65/35, v/v) at a flow rate of 0.9 ml/min, with the column being thermostated at +35 degrees C (UV detection at 257 nm). Under these conditions, retention times were approximately 17, 28, 31 and 76 min for R-Rog, S-Rog, R-Nox and S-Nox, respectively. S-aminoglutethimide (S-Ag) served as the internal standard (retention time 70 min). An extraction procedure from plasma samples was developed on Bond Elut RP8 500-mg cartridges; conditioning was performed with 5 ml methanol and 5 ml water, after which 1 ml plasma that had previously been spiked with 5 microM S-Ag was applied. Washing was done with 6 ml water and elution, with 4 ml methanol. After evaporation to dryness, residues were dissolved in 400 microliters anhydrous ethanol and 12-48 microliters was injected onto the HPLC system. Blank plasma from healthy donors showed the random presence of a small interference eluting at the retention time of R-Rog, precluding the accurate quantification of R-Rog concentrations below 2.5 microM. Reproducibility assays demonstrated the need to use an internal standard. Taking into account the internal standard, at 2.5 microM the intra- and inter-assay coefficients of variation were 10.5% and 21.0% for R-Rog 5.5% and 8.7% for S-Rog, 7.6% and 20.8% for R-Nox and 11.7% and 6.4% for S-Nox, respectively. The detection limit was 2.5 microM for R-Rog, 0.5 microM for S-Rog, 0.25 microM for R-Nox and 0.5 microM for S-Nox. Linearity was satisfactory at concentrations ranging from 2.5 to 10 microM for R-Rog, from 0.5 to 10 microM for S-Rog, from 0.25 to 2.5 microM for R-Nox and from 0.50 to 2

  20. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA for Infectious Diseases

    Directory of Open Access Journals (Sweden)

    Harpal Singh

    2015-07-01

    Full Text Available Enzyme-linked Immunosorbent Assay (ELISA-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  1. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines. PMID:26184194

  2. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases.

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-07-08

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a '3D well' was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  3. Performance Characteristics of CA 19-9 Radioimmunoassay and Clinical Significance of Serum CA 19-9 Assay in Patients with Malignancy

    International Nuclear Information System (INIS)

    Kim, Sang Eun; Shong, Young Kee; Cho, Bo Youn; Kim, Noe Kyeong; Koh, Chang Soon; Lee, Mun Ho; Hong, Seong Woon; Hong, Kee Suk

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum. CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. The results were as follows; 1) The CA 19-9 radioimmunoassay was simple to perform and can be completed in one work day. And the between-assay reproducibility and the assay recovery were both excellent. 2) The mean serum CA 19-9 level in 135 normal controls was 8.4±4.2 U/mL. Normal upper limit of serum CA 19-9 was defined as 21.0 U/mL. 4 out of 135 (3.0%) normal controls showed elevated CA 19-9 levels above the normal upper limit. 3) One out of 20 (5.0%) patients with benign gastrointestinal diseases showed elevated serum CA 19-9 level above the normal upper limit. 4) In 81 patients with various untreated malignancy, 41 patients (50.6%) showed elevated serum CA 19-9 levels. 66.7% of 18 patients with colorectal cancer, 100% of 2 patients with pancreatic cancer, 100% of 3 patients with common bile duct cancer, 47.1% of 17 patients with stomach cancer, 28.6% of 28 patients with hepatoma and 60.0% of 5 gastrointestinal tract cancers showed elevated serum CA 19-9 levels. 5) The sensitivities of serum CA 19-9 related to respectability in colorectal and stomach cancer were 33.3% in resectable colorectal cancer, 83.3% in unresectable colorectal cancer, 41.7% in resectable stomach cancer, 60.0% in unresectable stomach cancer respectively. 6) The sensitivity of serum CA 19-9 in 9 patients of postoperative colorectal cancer without recurrence were 33.3% and significantly decreased compared with that of untreated colorectal cancer, 66.7% (p<0.05). 7) In Patients with colorectal cancer

  4. Technical and clinical performance of a new assay to detect squamous cell carcinoma antigen levels for the differential diagnosis of cervical, lung, and head and neck cancer.

    Science.gov (United States)

    Holdenrieder, Stefan; Molina, Rafael; Qiu, Ling; Zhi, Xiuyi; Rutz, Sandra; Engel, Christine; Kasper-Sauer, Pia; Dayyani, Farshid; Korse, Catharina M

    2018-04-01

    In squamous cell carcinoma, squamous cell carcinoma antigen levels are often elevated. This multi-center study evaluated the technical performance of a new Elecsys ® squamous cell carcinoma assay, which measures serum squamous cell carcinoma antigen 1 and 2 levels in an equimolar manner, and investigated the potential of squamous cell carcinoma antigen for differential diagnosis of cervical, lung, and head and neck squamous cell carcinoma.Assay precision and method comparison experiments were performed across three European sites. Reference ranges for reportedly healthy individuals were determined using samples from banked European and Chinese populations. Differential diagnosis experiments determined whether cervical, lung, or head and neck cancer could be differentiated from apparently healthy, benign, or other malignant cohorts using squamous cell carcinoma antigen levels alone. Squamous cell carcinoma antigen cut-off levels were calculated based on squamous cell carcinoma antigen levels at 95% specificity. Repeatability coefficients of variation across nine analyte concentrations were ≤5.3%, and intermediate precision coefficients of variation were ≤10.3%. Method comparisons showed good correlations with Architect and Kryptor systems (slopes of 1.1 and 1.5, respectively). Reference ranges for 95th percentiles for apparently healthy individuals were 2.3 ng/mL (95% confidence interval: 1.9-3.8; European cohort, n = 153) and 2.7 ng/mL (95% confidence interval: 2.2-3.3; Chinese cohort, n = 146). Strongest differential diagnosis results were observed for cervical squamous cell carcinoma: receiver operating characteristic analysis showed that squamous cell carcinoma antigen levels (2.9 ng/mL cut-off) differentiate cervical squamous cell carcinoma (n = 127) from apparently healthy females (n = 286; area under the curve: 86.2%; 95% confidence interval: 81.8-90.6; sensitivity: 61.4%; specificity: 95.6%), benign diseases (n = 187; area

  5. The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens

    Directory of Open Access Journals (Sweden)

    Broukhanski George

    2008-09-01

    Full Text Available Abstract The Seeplex™ TB Detection-2 assay (Rockville, MD is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay.

  6. Diagnostic value of islet autoantibody assays practised in Russia. 1. Classic immunofluorescence islet cell antibody assay, immunoradiometric glutamic acid decarboxylase antibody assay, and ELISA tyrosine phosphatase antibody and insulin antibody assays

    Directory of Open Access Journals (Sweden)

    Alexei V. Timofeev

    2016-09-01

    Conclusions. We recommend to use ICA, IA-2A and GADA tests surveyed in our study for diagnosis of DM type 1 and differential diagnosis of DM. We don’t recommend IA testing with an Orgentec Anti-Insulin ELISA kit for usage in clinical practice.

  7. Determination of vitamin B6 vitamers and pyridoxic acid in plasma: development and evaluation of a high-performance liquid chromatographic assay

    DEFF Research Database (Denmark)

    Bisp, Marianne R; Bor, Mustafa Vakur; Heinsvig, Else-Marie

    2002-01-01

    buffer containing 1 g/L sodium bisulfite. The performance of the assay was evaluated by analyzing six plasma samples with interrelated concentration and two control samples (unspiked and vitamer spiked) over a 3-months period. The HPLC method was able to identify PLP, 4-PA, PM, PL, PN, and PMP from all...... other compounds in plasma in an analytical run of 46 min. The imprecisions and mean values (presented in parenthesis in nmol/L) were (unspiked and spiked sample) 9-8% (41-65) for PLP, 12-7% (18-40) for 4-PA, 67-28% (4-19) for PL, 15% (21) for PN, 10% (27) for PM, and 27% (17) for PMP. All three B6...... will be suitable for routine quantitation of PLP and 4-PA in human plasma. Udgivelsesdato: 2002-Jun-1...

  8. High-performance liquid chromatography coupled with post-column dual-bioactivity assay for simultaneous screening of xanthine oxidase inhibitors and free radical scavengers from complex mixture.

    Science.gov (United States)

    Li, D Q; Zhao, J; Li, S P

    2014-06-06

    Xanthine oxidase (XO) can catalyze hypoxanthine and xanthine to generate uric acid and reactive oxygen species (ROS), including superoxide anion radical (O₂(•-)) and hydrogen peroxide. XO inhibitors and free radical scavengers are beneficial to the treatment of gout and many related diseases. In the present study, an on-line high-performance liquid chromatography (HPLC) coupled with post-column dual-bioactivity assay was established and successfully applied to simultaneously screening of XO inhibitors and free radical scavengers from a complex mixture, Oroxylum indicum extract. The integrated system of HPLC separation, bioactivity screening and mass spectrometry identification was proved to be simple and effective for rapid and sensitive screening of individual bioactive compounds in complex mixtures. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A high-performance liquid chromatography-based radiometric assay for sucrose-phosphate synthase and other UDP-glucose requiring enzymes

    International Nuclear Information System (INIS)

    Salvucci, M.E.; Crafts-Brandner, S.J.

    1991-01-01

    A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, [14C]sucrose phosphate, from unreacted uridine 5'-diphosphate-[14C]glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts

  10. In vitro assays for predicting tumor cell response to radiation by apoptotic pathways

    International Nuclear Information System (INIS)

    Algan, Oe.; Hanks, G.E.; Biade, S.; Chapman, J.D.

    1995-01-01

    Purpose: We had previously shown that the rate of spontaneous and radiation-induced apoptosis was significantly greater in well-differentiated compared to anaplastic Dunning prostate carcinomas. The goal of this study was to define the most useful assay for quantifying radiation-induced apoptotic cell death and to determine if measured rates of radiation-induced apoptosis in tumor cell populations can predict treatment outcome. Materials and Methods: The time course and extent of radiation-induced apoptosis after single doses of Cesium-137 gamma-rays were measured by five different assays. These included gross DNA degradation, nucleosome ladder formation, labeling of 3'-OH ends in DNA with an immunofluorescence probe, immunofluorescence vital stains (LIVE/DEAD[reg] EUKOLIGHT TM ) and trypan blue. The majority of these studies were performed with DU-145 human prostate cells. Data was analyzed to determine the component of cell inactivation resulting from apoptosis with the modified linear quadratic equation, -1n (SF) = (α a + α p ) D + β p D 2 , were α a represents cell inactivation by radiation-induced apoptosis, α p and β p represent cell death by proliferative mechanisms and D represents radiation dose. Results: These studies indicated that DU-145 cell death after radiation occurs over two distinct time periods. The first phase of death begins shortly after irradiation and plateaus within 16-24 hr. This process of cell death has properties consistent with apoptosis as determined by 3'-OH DNA end-labeling and nucleosome ladder assays. The second phase of cell death (determined by viability staining) begins approximately 48 hr after irradiation and continues until the remainder of inactivated cells express their death. This longer phase of cell inactivation probably represents proliferative cell death and other non-apoptotic mechanisms. The five different assays were performed on DU-145 cells 24 hr after irradiation with 10 Gy. Significant nucleosome ladders

  11. Development of immunofluorescence colony staining (IFC) for detection of Xanthomonas campestris pv. vesicatoria and Clavibacter michiganensis subsp michiganensis in tomato seeds

    NARCIS (Netherlands)

    Nemeth, J.; Vuurde, van J.W.L.

    2006-01-01

    Immunofluorescence colony-staining (IFC) is based on sample pour plating in combination with immunofluorescence staining for recognition of the target colony. IFC was optimised for detecting Xanthomonas campestris pv. vesicatoria (Xcv) and Clavibacter michiganensis subsp. michiganensis (Cmm) in

  12. Nail unit in collagen vascular diseases: A clinical, histopathological and direct immunofluorescence study

    Directory of Open Access Journals (Sweden)

    Nabil P

    2006-01-01

    Full Text Available Background: Abnormalities of the nail unit are common in patients with connective tissue diseases. Clinical examination of the nail unit, coupled with biopsy of proximal nail fold offers an additional advantage in the diagnosis. Purpose: Our aim was to record clinical changes of the nail unit in connective tissue diseases and to study the histopathological (both H and E and periodic acid Schiff and direct immunofluorescence (DIF findings of nail-fold biopsy. Materials and Methods: Thirty-eight confirmed cases connective tissue diseases attending skin OPD were enrolled in the study. After detailed clinical examination of the nail unit, a crescentric biopsy was taken from the proximal nail fold (PNF. Histopathological and DIF studies were was carried out. Findings: Nail changes could be demonstrated in 65% connective tissue diseases. Specific histopathological (H and E and immunofluorescence findings were also encountered in many patients. Conclusion: Clinical examination of the nail unit offers additional clue in the diagnosis of connective tissue diseases. Though DIF of PNF biopsy is useful in the diagnosis, it is not an ideal site for H and E study, as the yield is very low. Limitations: Lack of adequate comparison group and non-utilization of capillary microscopy for the detection of nail fold capillary abnormalities.

  13. Kidney lesions in Rocky Mountain spotted fever: a light-, immunofluorescence-, and electron-microscopic study.

    Science.gov (United States)

    Bradford, W. D.; Croker, B. P.; Tisher, C. C.

    1979-01-01

    The essential pathologic lesion in Rocky Mountain spotted fever (RMSF) is a vasculitis that may involve the kidneys as well as the heart, brain, skin, and subcutaneous tissues. Histopathologic information concerning the response of the kidneys in RMSF is rather limited, however. In this study renal tissue from 17 children who died of RMSF was examined by light, electron, and immunofluorescence microscopy. A lymphocytic or mixed inflammation, or both, involving vessels and interstitium of the kidney was found in all patients. In addition, 10 patients had histologic evidence of acute tubular necrosis, and another 3 had glomerular lesions consisting of focal segmental tuft necrosis or increased cellularity secondary to neutophilic infiltration, or both. Immunofluorescence- and electron-microscopic studies failed to demonstrate immune-complex deposition within glomeruli, a finding that suggests that immunoglobulin and classic immune complexes were not involved in the pathogenesis of the renal lesions at the time of death. These findings suggest the possibility that the pathogenesis of the renal lesion in RMSF may be due to a direct action of the organism (Rickettsia rickettsii) on the vessel wall. Images Figure 2 Figure 1 PMID:525676

  14. EUROPattern Suite technology for computer-aided immunofluorescence microscopy in autoantibody diagnostics.

    Science.gov (United States)

    Krause, C; Ens, K; Fechner, K; Voigt, J; Fraune, J; Rohwäder, E; Hahn, M; Danckwardt, M; Feirer, C; Barth, E; Martinetz, T; Stöcker, W

    2015-04-01

    Antinuclear autoantibodies (ANA) are highly informative biomarkers in autoimmune diagnostics. The increasing demand for effective test systems, however, has led to the development of a confusingly large variety of different platforms. One of them, the indirect immunofluorescence (IIF), is regarded as the common gold standard for ANA screening, as described in a position statement by the American College of Rheumatology in 2009. Technological solutions have been developed aimed at standardization and automation of IIF to overcome methodological limitations and subjective bias in IIF interpretation. In this review, we present the EUROPattern Suite, a system for computer-aided immunofluorescence microscopy (CAIFM) including automated acquisition of digital images and evaluation of IIF results. The system was originally designed for ANA diagnostics on human epithelial cells, but its applications have been extended with the latest system update version 1.5 to the analysis of antineutrophil cytoplasmic antibodies (ANCA) and anti-dsDNA antibodies. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Choice of Illumination System & Fluorophore for Multiplex Immunofluorescence on FFPE Tissue Sections.

    Directory of Open Access Journals (Sweden)

    Sandrine Prost

    Full Text Available The recent availability of novel dyes and alternative light sources to facilitate complex tissue immunofluorescence studies such as multiplex labelling has not been matched by reports critically evaluating the considerations and relative benefits of these new tools, particularly in combination. Product information is often limited to wavelengths used for older fluorophores (FITC, TRITC & corresponding Alexa dyes family. Consequently, novel agents such as Quantum dots are not widely appreciated or used, despite highly favourable properties including extremely bright emission, stability and potentially reduced tissue autofluorescence at the excitation wavelength. Using spectral analysis, we report here a detailed critical appraisal and comparative evaluation of different light sources and fluorophores in multiplex immunofluorescence of clinical biopsy sections. The comparison includes mercury light, metal halide and 3 different LED-based systems, using 7 Qdots (525, 565, 585, 605, 625, 705, Cy3 and Cy5. We discuss the considerations relevant to achieving the best combination of light source and fluorophore for accurate multiplex fluorescence quantitation. We highlight practical limitations and confounders to quantitation with filter-based approaches.

  16. Enzyme-linked immunosorbent assay and polymerase chain reaction performance using Mexican and Guatemalan discrete typing unit I strains of Trypanosoma cruzi.

    Science.gov (United States)

    Ballinas-Verdugo, Martha; Reyes, Pedro Antonio; Mejia-Dominguez, Ana; López, Ruth; Matta, Vivian; Monteón, Victor M

    2011-12-01

    Thirteen Trypanosoma cruzi isolates from different geographic regions of Mexico and Guatemala belonging to discrete typing unit (DTU) I and a reference CL-Brener (DTU VI) strain were used to perform enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR). A panel of 57 Mexican serum samples of patients with chronic chagasic cardiopathy and asymptomatic infected subjects (blood bank donors) were used in this study. DNA from the above 14 T. cruzi strains were extracted and analyzed by PCR using different sets of primers designed from minicircle and satellite T. cruzi DNA. The chronic chagasic cardiopathy serum samples were easily recognized with ELISA regardless of the source of antigenic extract used, even with the CL-Brener TcVI, but positive serum samples from blood bank donors in some cases were not recognized by some Mexican antigenic extracts. On the other hand, PCR showed an excellent performance despite the set of primers used, since all Mexican and Guatemalan T. cruzi strains were correctly amplified. In general terms, Mexican, Guatemalan, and CL-Brener T. cruzi strains are equally good sources of antigen when using the ELISA test to detect Mexican serum samples. However, there are some strains with poor performance. The DTU I strains are easily detected using either kinetoplast or satellite DNA target designed from DTU VI strains.

  17. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  18. Analytical Performance of Four Polymerase Chain Reaction (PCR and Real Time PCR (qPCR Assays for the Detection of Six Leishmania Species DNA in Colombia

    Directory of Open Access Journals (Sweden)

    Cielo M. León

    2017-10-01

    Full Text Available Leishmaniasis comprises a spectrum of parasitic diseases caused by protozoans of the genus Leishmania. Molecular tools have been widely employed for the detection of Leishmania due to its high sensitivity and specificity. However, the analytical performance of molecular platforms as PCR and real time PCR (qPCR including a wide variety of molecular markers has never been evaluated. Herein, the aim was to evaluate the analytical performance of 4 PCR-based assays (designed on four different targets and applied on conventional and real-time PCR platforms. We evaluated the analytical performance of conventional PCR and real time PCR, determining exclusivity and inclusivity, Anticipated Reportable Range (ARR, limit of detection (LoD and accuracy using primers directed to kDNA, HSP70, 18S and ITS-1 targets. We observed that the kDNA was the most sensitive but does not meet the criterion of exclusivity. The HSP70 presented a higher LoD in conventional PCR and qPCR in comparison with the other markers (1 × 101 and 1 × 10-1 equivalent parasites/mL respectively and had a higher coefficient of variation in qPCR. No statistically significant differences were found between the days of the test with the four molecular markers. The present study revealed that the 18S marker presented the best performance in terms of analytical sensitivity and specificity for the qPCR in the species tested (species circulating in Colombia. Therefore, we recommend to explore the analytical and diagnostic performance in future studies using a broader number of species across America.

  19. Analytical Performance of Four Polymerase Chain Reaction (PCR) and Real Time PCR (qPCR) Assays for the Detection of Six Leishmania Species DNA in Colombia

    Science.gov (United States)

    León, Cielo M.; Muñoz, Marina; Hernández, Carolina; Ayala, Martha S.; Flórez, Carolina; Teherán, Aníbal; Cubides, Juan R.; Ramírez, Juan D.

    2017-01-01

    Leishmaniasis comprises a spectrum of parasitic diseases caused by protozoans of the genus Leishmania. Molecular tools have been widely employed for the detection of Leishmania due to its high sensitivity and specificity. However, the analytical performance of molecular platforms as PCR and real time PCR (qPCR) including a wide variety of molecular markers has never been evaluated. Herein, the aim was to evaluate the analytical performance of 4 PCR-based assays (designed on four different targets) and applied on conventional and real-time PCR platforms. We evaluated the analytical performance of conventional PCR and real time PCR, determining exclusivity and inclusivity, Anticipated Reportable Range (ARR), limit of detection (LoD) and accuracy using primers directed to kDNA, HSP70, 18S and ITS-1 targets. We observed that the kDNA was the most sensitive but does not meet the criterion of exclusivity. The HSP70 presented a higher LoD in conventional PCR and qPCR in comparison with the other markers (1 × 101 and 1 × 10-1 equivalent parasites/mL respectively) and had a higher coefficient of variation in qPCR. No statistically significant differences were found between the days of the test with the four molecular markers. The present study revealed that the 18S marker presented the best performance in terms of analytical sensitivity and specificity for the qPCR in the species tested (species circulating in Colombia). Therefore, we recommend to explore the analytical and diagnostic performance in future studies using a broader number of species across America. PMID:29046670

  20. Effect-directed fingerprints of 77 botanical extracts via a generic high-performance thin-layer chromatography method combined with assays and mass spectrometry.

    Science.gov (United States)

    Krüger, S; Hüsken, L; Fornasari, R; Scainelli, I; Morlock, G E

    2017-12-22

    Quantitative effect-directed profiles of 77 industrially and freshly extracted botanicals like herbs, spices, vegetables and fruits, widely used as food ingredients, dietary supplements or traditional medicine, gave relevant information on their quality. It allows the assessment of food, dietary supplements and phytomedicines with regard to potential health-promoting activities. In contrary to sum parameter assays and targeted analysis, chromatography combined with effect-directed analysis allows fast assignment of single active compounds and evaluation of their contribution to the overall activity, originating from a food or botanical sample. High-performance thin-layer chromatography was hyphenated with UV/Vis/FLD detection and effect-directed analysis, using the 2,2-diphenyl-1-picrylhydrazyl radical, Gram-negative Aliivibrio fischeri, Gram-positive Bacillus subtilis, acetylcholinesterase and tyrosinase assays. Bioactive compounds of interest were eluted using an elution head-based interface and further characterized by electrospray ionization (high-resolution) mass spectrometry. This highly streamlined workflow resulted in a hyphenated HPTLC-UV/Vis/FLD-EDA-ESI + /ESI - -(HR)MS method. The excellent quantification power of the method was shown on three compounds. For rosmarinic acid, contents ranged from 4.5mg/g (rooibos) to 32.6mg/g (rosemary), for kaempferol-3-glucoside from 0.6mg/g (caraway) to 4.4mg/g (wine leaves), and for quercetin-3-glucoside from 1.1mg/g (hawthorn leaves) to 17.7mg/g (thyme). Three mean repeatabilities (%RSD) over 18 quantifications for the three compounds were ≤2.2% and the mean intermediate precision over three different days (%RSD, n=3) was 5.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  2. Rover waste assay system

    International Nuclear Information System (INIS)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J.

    1997-01-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235 U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137 Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  3. Performance evaluation of cobas HBV real-time PCR assay on Roche cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test.

    Science.gov (United States)

    Kim, Hanah; Hur, Mina; Bae, Eunsin; Lee, Kyung-A; Lee, Woo-In

    2018-02-19

    Hepatitis B virus (HBV) nucleic acid amplification testing (NAAT) is important for the diagnosis and management of HBV infection. We evaluated the analytical performance of the cobas HBV NAAT (Roche Diagnostics GmbH, Mannheim, Germany) on the cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test (CAP/CTM HBV). Precision was evaluated using three levels of cobas HBV/HCV/HIV-1 Control Kit, and linearity was evaluated across the anticipated measuring range (10.0-1.0×109 IU/mL) at seven levels using clinical samples. Detection capability, including limit of blank (LOB), limit of detection (LOD) and limit of quantitation (LOQ), was verified using the 4th WHO International Standard for HBV DNA for NAT (NIBSC code: 10/266). Correlation between the two systems was compared using 205 clinical samples (102 sera and 103 EDTA plasma). Repeatability and total imprecision (coefficient of variation) ranged from 0.5% to 3.8% and from 0.5% to 3.5%, respectively. Linearity (coefficient of determination, R2) was 0.999. LOB, LOD and LOQ were all acceptable within the observed proportion rate (85%). Correlation was very high between the two systems in both serum and plasma samples (correlation coefficient [r]=0.995). The new cobas HBV real-time PCR assay on the cobas 4800 System showed reliable analytical performances.

  4. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  5. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  6. Selection of donor platelets for alloimmunized patients using a platelet-associated IgG assay

    International Nuclear Information System (INIS)

    Myers, T.J.; Kim, B.K.; Steiner, M.; Baldini, M.G.

    1981-01-01

    A quantitative immunofluorescence platelet-associated immunoglobulin-G (PA-IgG) assay was used to detect alloimmunity to platelets in 8/12 multitransfused patients and to perform platelet crossmatching in the 8 alloimmunized patients. The correct separation of multitransfused patients into alloimmune and nonalloimmune groups was substantiated with chromium-51-labeled platelet survival studies. For 5 alloimmunized patients, compatible and incompatible donor platelets were demonstrated by PA-IgG crossmatching and were confirmed by platelet survival studies. With the other 3 alloimmunized patients, only Pa-IgG incompatible donor platelets were found. Survival studies with 5 of these incompatible donor platelets showed markedly reduced survival times on 4 occasions. Pa-IgG compatible donor platelets survived 3.5 to 8.7 days, while Pa-IgG incompatible platelets showed survival times of 0.1 to 2.4 days

  7. Comparative determination of the rheumatic factor by means of agglutination, immunofluorescence and radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, L.; Storz, H.; Hein, G.; Schlenvoigt, G. (Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin)

    1982-01-01

    The rheumatic factor (RF) was determined by means of agglutination, immunofluorescence (IF) test and radioimmunoassay (RIPEGA) in random groups of 56 patients with rheumatoid arthritis (RA), 13 patients with seronegative RA and 39 patients with psoriasis arthropathica. All three methods are of equal value with regard to the number of positive results. Further classification of seronegative patients, i.e. patients with a negative agglutination reaction and the clinical symptoms of RA is possible with the IF method and, above all, by means of RIPEGA. But because of the comprehensive test devices the two methods are only an alternative. Titer differences are attributed to the different indication principles and the immunological heterogeneity of RF. An improvement of the diagnosis of activity was not possible.

  8. Comparative determination of the rheumatic factor by means of agglutination, immunofluorescence and radioimmunoassay

    International Nuclear Information System (INIS)

    Jaeger, L.; Storz, H.; Hein, G.; Schlenvoigt, G.

    1982-01-01

    The rheumatic factor (RF) was determined by means of agglutination, immunofluorescence (IF) test and radioimmunoassay (RIPEGA) in random groups of 56 patients with rheumatoid arthritis (RA), 13 patients with seronegative RA and 39 patients with psoriasis arthropathica. All three methods are of equal value with regard to the number of positive results. Further classification of seronegative patients, i.e. patients with a negative agglutination reaction and the clinical symptoms of RA is possible with the IF method and, above all, by means of RIPEGA. But because of the comprehensive test devices the two methods are only an alternative. Titer differences are attributed to the different indication principles and the immunological heterogeneity of RF. An improvement of the diagnosis of activity was not possible. (author)

  9. Diagnostic performance of a novel loop-mediated isothermal amplification (LAMP) assay targeting the apicoplast genome for malaria diagnosis in a field setting in sub-Saharan Africa.

    Science.gov (United States)

    Oriero, Eniyou C; Okebe, Joseph; Jacobs, Jan; Van Geertruyden, Jean-Pierre; Nwakanma, Davis; D'Alessandro, Umberto

    2015-10-09

    New diagnostic tools to detect reliably and rapidly asymptomatic and low-density malaria infections are needed as their treatment could interrupt transmission. Isothermal amplification techniques are being explored for field diagnosis of malaria. In this study, a novel molecular tool (loop-mediated isothermal amplification-LAMP) targeting the apicoplast genome of Plasmodium falciparum was evaluated for the detection of asymptomatic malaria-infected individuals in a rural setting in The Gambia. A blood was collected from 341 subjects (median age 9 years, range 1-68 years) screened for malaria. On site, a rapid diagnostic test (RDT, SD Bioline Malaria Antigen P.f) was performed, thick blood films (TBF) slides for microscopy were prepared and dry blood spots (DBS) were collected on Whatman(®) 903 Specimen collection paper. The TBF and DBS were transported to the field laboratory where microscopy and LAMP testing were performed. The latter was done on DNA extracted from the DBS using a crude (methanol/heating) extraction method. A laboratory-based PCR amplification was done on all the samples using DNA extracted with the Qiagen kit and its results were taken as reference for all the other tests. Plasmodium falciparum malaria prevalence was 37 % (127/341) as detected by LAMP, 30 % (104/341) by microscopy and 37 % (126/341) by RDT. Compared to the reference PCR method, sensitivity was 92 % for LAMP, 78 % for microscopy, and 76 % for RDT; specificity was 97 % for LAMP, 99 % for microscopy, and 88 % for RDT. Area under the receiver operating characteristic (ROC) curve in comparison with the reference standard was 0.94 for LAMP, 0.88 for microscopy and 0.81 for RDT. Turn-around time for the entire LAMP assay was approximately 3 h and 30 min for an average of 27 ± 9.5 samples collected per day, compared to a minimum of 10 samples an hour per operator by RDT and over 8 h by microscopy. The LAMP assay could produce reliable results the same day of the screening. It could

  10. Multiplexed Immunofluorescence Reveals Potential PD-1/PD-L1 Pathway Vulnerabilities in Craniopharyngioma.

    Science.gov (United States)

    Coy, Shannon; Rashid, Rumana; Lin, Jia-Ren; Du, Ziming; Donson, Andrew M; Hankinson, Todd C; Foreman, Nicholas K; Manley, Peter E; Kieran, Mark W; Reardon, David A; Sorger, Peter K; Santagata, Sandro

    2018-03-02

    Craniopharyngiomas are neoplasms of the sellar/parasellar region that are classified into adamantinomatous (ACP) and papillary (PCP) subtypes. Surgical resection of craniopharyngiomas is challenging, and recurrence is common, frequently leading to profound morbidity. BRAF V600E mutations render PCP susceptible to BRAF/MEK inhibitors, but effective targeted therapies are needed for ACP. We explored the feasibility of targeting the PD-1/PD-L1 immune checkpoint pathway in ACP and PCP. We mapped and quantified PD-L1 and PD-1 expression in ACP and PCP resections using immunohistochemistry, immunofluorescence, and RNA in situ hybridization. We used tissue-based cyclic immunofluorescence (t-CyCIF) to map the spatial distribution of immune cells and characterize cell cycle and signaling pathways in ACP tumor cells which intrinsically express PD-1. All ACP (15±14% of cells, n=23, average±S.D.) and PCP (35±22% of cells, n=18) resections expressed PD-L1. In ACP, PD-L1 was predominantly expressed by tumor cells comprising the cyst-lining. In PCP, PD-L1 was highly-expressed by tumor cells surrounding the stromal fibrovascular cores. ACP also exhibited tumor cell-intrinsic PD-1 expression in whorled epithelial cells with nuclear-localized beta-catenin. These cells exhibited evidence of elevated mTOR and MAPK signaling. Profiling of immune populations in ACP and PCP showed a modest density of CD8+ T-cells. ACP exhibit PD-L1 expression in the tumor cyst-lining and intrinsic PD-1 expression in cells proposed to comprise an oncogenic stem-like population. In PCP, proliferative tumor cells express PD-L1 in a continuous band at the stromal-epithelial interface. Targeting PD-L1 and/or PD-1 in both subtypes of craniopharyngioma might therefore be an effective therapeutic strategy.

  11. Variability in the recognition of distinctive immunofluorescence patterns in different brands of HEp-2 cell slides

    Directory of Open Access Journals (Sweden)

    Alessandra Dellavance

    2013-06-01

    Full Text Available INTRODUCTION: Indirect immunofluorescence on HEp-2 cells is considered the gold standard for the detection of autoantibodies against cellular antigens. However, the culture conditions, cell fixation and permeabilization processes interfere directly in the preservation and spatial distribution of antigens. Therefore, one can assume that certain peculiarities in the processing of cellular substrate may affect the recognition of indirect immunofluorescence patterns associated with several autoantibodies. OBJECTIVE: To evaluate a panel of serum samples representing nuclear, nucleolar, cytoplasmic, mitotic apparatus, and chromosome plate patterns on HEp-2 cell substrates from different suppliers. MATERIALS AND METHODS: Seven blinded observers, independent from the three selected reference centers, evaluated 17 samples yielding different nuclear, nucleolar, cytoplasmic and mitotic apparatus patterns on HEp-2 cell slides from eight different brands. The slides were coded to maintain confidentiality of both brands and participating centers. RESULTS: The 17 HEp-2 cell patterns were identified on most substrates. Nonetheless, some slides showed deficit in the expression of several patterns: nuclear coarse speckled/U1-ribonucleoprotein associated with antibodies against RNP (U1RNP, centromeric protein F (CENP-F, proliferating cell nuclear antigen (PCNA, cytoplasmic fine speckled associated with anti-Jo-1 antibodies (histidyl synthetase, nuclear mitotic apparatus protein 1 (NuMA-1 and nuclear mitotic apparatus protein 2 (NuMA-2. CONCLUSION: Despite the overall good quality of the assessed HEp-2 substrates, there was considerable inconsistency in results among different commercial substrates. The variations may be due to the evaluated batches, hence generalizations cannot be made as to the respective brands. It is recommended that each new batch or new brand be tested with a panel of reference sera representing the various patterns.

  12. Assessing the performance of a Loop Mediated Isothermal Amplification (LAMP) assay for the detection and subtyping of high-risk suptypes of Human Papilloma Virus (HPV) for Oropharyngeal Squamous Cell Carcinoma (OPSCC) without DNA purification.

    Science.gov (United States)

    Rohatensky, Mitchell G; Livingstone, Devon M; Mintchev, Paul; Barnes, Heather K; Nakoneshny, Steven C; Demetrick, Douglas J; Dort, Joseph C; van Marle, Guido

    2018-02-08

    Oropharyngeal Squamous Cell Carcinoma (OPSCC) is increasing in incidence despite a decline in traditional risk factors. Human Papilloma Virus (HPV), specifically subtypes 16, 18, 31 and 35, has been implicated as the high-risk etiologic agent. HPV positive cancers have a significantly better prognosis than HPV negative cancers of comparable stage, and may benefit from different treatment regimens. Currently, HPV related carcinogenesis is established indirectly through Immunohistochemistry (IHC) staining for p16, a tumour suppressor gene, or polymerase chain reaction (PCR) that directly tests for HPV DNA in biopsied tissue. Loop mediated isothermal amplification (LAMP) is more accurate than IHC, more rapid than PCR and is significantly less costly. In previous work we showed that a subtype specific HPV LAMP assay performed similar to PCR on purified DNA. In this study we examined the performance of this LAMP assay without DNA purification. We used LAMP assays using established primers for HPV 16 and 18, and new primers for HPV 31 and 35. LAMP reaction conditions were tested on serial dilutions of plasmid HPV DNA to confirm minimum viral copy number detection thresholds. LAMP was then performed directly on different human cell line samples without DNA purification. Our LAMP assays could detect 10 5 , 10 3 , 10 4 , and 10 5 copies of plasmid DNA for HPV 16, 18, 31, and 35, respectively. All primer sets were subtype specific, with no cross-amplification. Our LAMP assays also reliably amplified subtype specific HPV DNA from samples without requiring DNA isolation and purification. The high risk OPSCC HPV subtype specific LAMP primer sets demonstrated, excellent clinically relevant, minimum copy number detection thresholds with an easy readout system. Amplification directly from samples without purification illustrated the robust nature of the assay, and the primers used. This lends further support HPV type specific LAMP assays, and these specific primer sets and assays

  13. Analytical and clinical performance of the Hologic Aptima HCV Quant Dx Assay for the quantification of HCV RNA in plasma samples

    DEFF Research Database (Denmark)

    Schønning, Kristian; Pedersen, Martin Schou; Johansen, Kim

    2017-01-01

    obtained from 13 patients undergoing treatment with DAAs. RESULTS: Deming regression of results from 187 plasma samples with HCV RNA >2 Log IU/mL indicated that the Aptima assay quantified higher than the CAPCTMv2 test for HCV RNA >4.9 Log IU/mL. The linearity of the Aptima assay was excellent across...

  14. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    Science.gov (United States)

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  15. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  16. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays.

    Science.gov (United States)

    Rezende, Vinicius Marcondes; Rivellis, Ariane; Novaes, Mafalda Megumi Yoshinaga; de Alencar Fisher Chamone, Dalton; Bendit, Israel

    2013-01-01

    Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring. A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500-10.0 μg/mL with a limit of detection of 0.155 μg/mL. Stability data for the analyte are also presented. Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.

  17. High-performance liquid chromatography assay using ultraviolet detection for urinary quantification of milrinone concentrations in cardiac surgery patients undergoing cardiopulmonary bypass.

    Science.gov (United States)

    Gavra, Paul; Nguyen, Anne Q N; Beauregard, Natasha; Denault, André Y; Varin, France

    2014-08-01

    An analytical assay using liquid-liquid extraction and high-performance liquid chromatography with ultraviolet detection was developed for the quantification of total (conjugated and unconjugated) urinary concentrations of milrinone after the inhalation of a 5 mg dose in 15 cardiac patients undergoing cardiopulmonary bypass. Urine samples (700 μL) were extracted with ethyl-acetate and subsequently underwent acid back-extraction before and after deconjugation by mild acid hydrolysis. Milrinone was separated on a strong cation exchange analytical column. The mobile phase consisted of a constant mixture of acetonitrile:tetrahydrofurane-NaH2 PO4 buffer (40:60 v/v, pH 3.0). Thirteen calibration curves were linear in the concentration range of 31.25-4000 ng/mL, using olprinone as the internal standard (r(2) range 0.9911-0.9999, n = 13). Mean milrinone recovery and accuracy were respectively 85.2 ± 3.1% and ≥93%. Intra- and inter-day precisions (coefficients of variation) were ≤5% and ≤8%, respectively. Over a 24 h collection period, the cumulative urinary milrinone recovered from 15 patients was 26.1 ± 7.7% of the nominal 5 mg dose administered. The relative amount of milrinone glucuronic acid conjugate was negligible in the urine of patients undergoing cardiopulmonary bypass This method proved to be reliable, specific and accurate to determine the cumulative amount of total milrinone recovered in urine after inhalation. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Assay of common sunscreen agents in suncare products by high-performance liquid chromatography on a cyanopropyl-bonded silica column.

    Science.gov (United States)

    Simeoni, Silvia; Tursilli, Rosanna; Bianchi, Anna; Scalia, Santo

    2005-06-15

    A rapid high-performance liquid chromatographic method was developed for the simultaneous assay of eight of the most common sunscreen agents (octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane, octyl-salicilate, methylbenzylidene camphor, octyl-dimethylamminobenzoate, phenylbenzimidazole sulphonic acid and octocrylene) in sun protection products. Evaluation of the influence of different stationary phases and eluents on the separation selectivity showed that optimal resolution was obtained on a cyanopropyl-silica column eluted with methanol-acetonitrile-tetrahydrofuran-aqueous acetic acid. A small adjustment of the proposed chromatographic system (reduction in the aqueous content of the mobile phase) permitted also the determination of the extremely hydrophobic UV filter, methylene bis-benzotriazolyl tetramethylbutylphenol along with three other sunscreen agents, octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane. Recoveries of the UV filters from the spiked formulation were between 95.7 and 103.7% and the precision of the method was better than 6.1% relative standard deviation. The developed HPLC procedure is suitable for quality control and photostability analyses of commercial suncare products.

  19. Comparative performance of PCR-based assay versus microscopy and culture for the direct detection of Mycobacterium tuberculosis in clinical respiratory specimens in Lebanon.

    Science.gov (United States)

    Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W

    2000-09-01

    American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.

  20. Performance of a RT-PCR Assay in Comparison to FISH and Immunohistochemistry for the Detection of ALK in Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Hout, David R; Schweitzer, Brock L; Lawrence, Kasey; Morris, Stephan W; Tucker, Tracy; Mazzola, Rosetta; Skelton, Rachel; McMahon, Frank; Handshoe, John; Lesperance, Mary; Karsan, Aly; Saltman, David L

    2017-08-01

    Patients with lung cancers harboring an activating anaplastic lymphoma kinase ( ALK ) rearrangement respond favorably to ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) are validated and widely used screening tests for ALK rearrangements but both methods have limitations. The ALK RGQ RT-PCR Kit (RT-PCR) is a single tube quantitative real-time PCR assay for high throughput and automated interpretation of ALK expression. In this study, we performed a direct comparison of formalin-fixed paraffin-embedded (FFPE) lung cancer specimens using all three ALK detection methods. The RT-PCR test (diagnostic cut-off Δ C t of ≤8) was shown to be highly sensitive (100%) when compared to FISH and IHC. Sequencing of RNA detected full-length ALK transcripts or EML4-ALK and KIF5B-ALK fusion variants in discordant cases in which ALK expression was detected by the ALK RT-PCR test but negative by FISH and IHC. The overall specificity of the RT-PCR test for the detection of ALK in cases without full-length ALK expression was 94% in comparison to FISH and sequencing. These data support the ALK RT-PCR test as a highly efficient and reliable diagnostic screening approach to identify patients with non-small cell lung cancer whose tumors are driven by oncogenic ALK.

  1. Intramolecular cyclization in irradiated nucleic acids: correlation between high-performance liquid chromatography and an immunochemical assay for 8,5'-cycloadenosine in irradiated poly(A)

    International Nuclear Information System (INIS)

    Fuciarelli, A.F.; Shum, F.Y.; Raleigh, J.A.

    1987-01-01

    A correlation between high-performance liquid chromatography (HPLC) analysis and an in situ enzyme-linked immunosorbent assay (ELISA) for 8,5'-cycloadenosine formation in irradiated poly(A) has been established. The correlation shows that the ELISA precisely reflects changes in the combined yield of R- and S-8,5'-cycloadenosine but that a correction factor must be applied to the ELISA values for accuracy. The HPLC analysis reveals that the intramolecular cyclization proceeds stereoselectively in irradiated poly(A) to preferentially produce the R isomer at pH 7.0 which is similar to the result for irradiated adenosine but in contrast to the result for 5'-AMP where the S isomer predominates at neutral pH. The HPLC analysis shows that two events originating in hydroxyl radical attack at the sugar phosphate backbone in poly(A); that is, adenine release and 8,5'-cycloadenosine formation have somewhat different dose-yield responses. The formation of 8-hydroxyadenosine was detected in the HPLC chromatograms of poly(A) irradiated under N2O at neutral pH, and the yield of this compound was similar to the yield observed in 5'-AMP or adenosine irradiated under similar conditions

  2. Clinical performance of LOCI™-based tumor marker assays for tumor markers CA 15-3, CA 125, CEA, CA 19-9 and AFP in gynecological cancers.

    Science.gov (United States)

    Dolscheid-Pommerich, Ramona C; Keyver-Paik, Mignon; Hecking, Thomas; Kuhn, Walther; Hartmann, Gunther; Stoffel-Wagner, Birgit; Holdenrieder, Stefan

    2017-10-01

    Evidence is sparse regarding the clinical performance of luminescent oxygen channeling immunoassays-based tumor marker assays in gynecological cancer. Analyzing serum samples of 336 patients with Dimension™Vista1500, we investigated the diagnostic power of carbohydrate antigen 15-3, carbohydrate antigen 125, carcinoembryonic antigen, carbohydrate antigen 19-9, and alpha-fetoprotein in patients suffering from different types of gynecological cancer and precancerous gynecological diseases and compared findings to appropriate control groups. The cohort comprised 177 female patients with gynecological cancers (73 breast, 22 cervical, 16 endometrial, 17 vulva, and 49 ovarian cancers), 26 patients with precancerous gynecological diseases (11 vulva, 4 cervical, and 10 breast), 109 patients with benign gynecological diseases, and 24 healthy controls. Discriminative power was assessed by areas under the curve in receiver operating characteristic curves, and sensitivities were determined at a fixed specificity of 95%. Levels of biomarkers in healthy controls were in the expected ranges and a discriminative power between gynecological cancers and healthy controls was observed for several tumor markers. Established tumor type-associated markers were elevated in specific gynecological cancers and benign controls as well as within precancerous gynecological diseases and healthy control group. In ovarian cancer, carbohydrate antigen 125 and carbohydrate antigen 15-3 were significantly elevated compared to the respective benign diseases. Carbohydrate antigen 125 was the most conclusive marker (area under the curve = 0.86% and 77.6% sensitivity at 95% specificity). In breast cancer, carcinoembryonic antigen and carbohydrate antigen 15-3 were significantly higher than in the respective benign diseases. Carcinoembryonic antigen achieved the most conclusive area under the curve (0.65) with 31.5% sensitivity at 95% specificity. None of the investigated markers was found to be of

  3. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  4. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  5. Dual isotope assays

    International Nuclear Information System (INIS)

    Smith, G.F.W.; Stevens, R.A.J.; Jacoby, B.

    1980-01-01

    Dual isotope assays for thyroid function are performed by carrying out a radio-immunoassay for two of thyroxine (T4), tri-iodothyronine (T3), thyroid stimulating hormone (TSH), and thyroxine binding globulin (TBG), by a method wherein a version of one of the thyroid components, preferably T4 or T3 is labelled with Selenium-75 and the version of the other thyroid component is labelled with a different radionuclide, preferably Iodine-125. (author)

  6. Correlation of antinuclear antibody immunofluorescence patterns with immune profile using line immunoassay in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Sebastian Wendy

    2010-07-01

    Full Text Available Background: Immunity status, individual response to disease and types of antibodies produced are well known to vary from person to person, place to place and probably from population to population. A broad spectrum of specific auto antibodies that have so far been associated with specific rheumatic diseases, as noted in Western literature, has been well taken as a reference standard all over the world. There is neither research work nor any data correlating the auto antibodies and their antinuclear antibody (ANA patterns with the immunoprofile in the Indian population to date. Aims: To understand a definite association between ANA patterns and specific antibodies in the serum in the Indian study population and to document similarities / differences with the West. Settings and Design: This prospective and retrospective double blind study was undertaken on the South Indian population referred for ANA testing by Indirect Immunofluorescence method and by immunoline methods. Materials and Methods: Serum samples of patients from a random South Indian population who sought medical help for rheumatic disease were subjected for ANA testing by indirect immunofluorescence (IIF method and line immunoassay during the study period of 27 months. Serum samples were processed in dilution of 1:100 using HEp - 2010 / liver biochip (Monkey (EUROIMMUN AG. The serum samples which were further processed for line immunoassay were treated in 1:100 dilution on nylon strips coated with recombinant and purified antigens as discrete lines with plastic backing (EUROIMMUN AG coated with antigens nRNP / Sm, Sm, SSA, Ro-52, SSB, Scl-70, PM-Scl, PCNA, Jo-1, CENP-B, dsDNA, nucleosomes, histones, ribosomal protein-P, anti-mitochondrial antibodies (AMA-M2 along with a control band. The analysis was done by comparing the intensity of the reaction with positive control line by image analysis. Results: The antinuclear antibody indirect immunofluorescence (ANA - IIF patterns obtained

  7. Fluorescence Adherence Inhibition Assay: A Novel Functional Assessment of Blocking Virus Attachment by Vaccine-Induced Antibodies.

    Directory of Open Access Journals (Sweden)

    Atul Asati

    Full Text Available Neutralizing antibodies induced by vaccination or natural infection play a critically important role in protection against the viral diseases. In general, neutralization of the viral infection occurs via two major pathways: pre- and post-attachment modes, the first being the most important for such infections as influenza and polio, the latter being significant for filoviruses. Neutralizing capacity of antibodies is typically evaluated by virus neutralization assays that assess reduction of viral infectivity to the target cells in the presence of functional antibodies. Plaque reduction neutralization test, microneutralization and immunofluorescent assays are often used as gold standard virus neutralization assays. However, these methods are associated with several important prerequisites such as use of live virus requiring safety precautions, tedious evaluation procedure and long assessment time. Hence, there is a need for a robust, inexpensive high throughput functional assay that can be performed rapidly using inactivated virus, without extensive safety precautions. Herein, we report a novel high throughput Fluorescence Adherence Inhibition assay (fADI using inactivated virus labeled with fluorescent secondary antibodies virus and Vero cells or erythrocytes as targets. It requires only few hours to assess pre-attachment neutralizing capacity of donor sera. fADI assay was tested successfully on donors immunized with polio, yellow fever and influenza vaccines. To further simplify and improve the throughput of the assay, we have developed a mathematical approach for calculating the 50% titers from a single sample dilution, without the need to analyze multi-point titration curves. Assessment of pre- and post-vaccination human sera from subjects immunized with IPOL®, YF-VAX® and 2013-2014 Fluzone® vaccines demonstrated high efficiency of the assay. The results correlated very well with microneutralization assay performed independently by the FDA

  8. Immunofluorescence pattern of antinuclear antibody and its association with autoantibody profile in systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Sadia Sharmin

    2016-08-01

    Full Text Available Background: Antinuclear antibody (ANA is useful in the diagnosis of systemic lupus erythematosus (SLE. Association of specific autoantibodies with the immunofluorescence pattern of ANA in SLE as noted in Western literature has been taken as reference in all over the world. However, in Bangladesh such research work or data correlating the autoantibodies and their ANA patterns is inadequate. Objective: To identify an association between immunofluorescence patterns of antinuclear antibody on HEp-2 cell and more specific antinuclear reactivities (e.g. anti-dsDNA and anti-extractable nuclear antigen in the serum samples of SLE patients.Methods: Serum samples of 37 SLE patients who were diagnosed by ARA (American Rheumatism Association classification criteria and laboratory tests, attending at lupus clinic of Bangabandhu Sheikh Mujib Medical University (BSMMU during the study period of six months were subjected for ANA testing by Indirect Imrnunofluorescence (IIF on HEp-2 cell, anti-dsDNA by ELISA and anti- extractable nuclear antigen (anti-ENA by Dot Immunoblot. Dot blot strips were tested for anti-Sm, anti-RNP, anti-SSA/Ro, and anti-SSB/La. Results: Out of 37 SLE patients 32 (86.5% cases were ANA positive by IIF on HEp-2 cell. ANA positive sera exhibited three fluorescence patterns such as speckled (43.7%, peripheral (34.3% and homogenous pattern (21.8%. Peripheral pattern (100% was strongly associated with anti-dsDNA (p<0.05 and homogenous pattern (85.7% was also predominantly associated with anti-dsDNA (p<0.05. Speckled pattern (85.6% was significantly associated with anti-ENA (p<0.05. Anti-dsDNA was positive in 75% of SLE cases and majority (45.8% of which showed peripheral pattern whereas anti-ENA was positive in 48.6% cases and majority (70.5% of which showed speckled pattern. The most commonly identified antinuclear autoreactivity was directed towards anti-RNP (22.2% then anti-Sm (16.6%, anti-SSA (16.6% and anti-SSB (11.1 %. Multiple anti

  9. Detection of viral infection by immunofluorescence in formalin-fixed tissues, pretreated with trypsin

    Directory of Open Access Journals (Sweden)

    O. M. Barth

    1988-06-01

    Full Text Available The presence of viral antigen in sections from formalin-fixed and paraffin-embedded human tissues was demonstrated by trypsin digestion followed by direct or indirect immunofluorescence. The specimens may be used for retrospective diagnosis. The immunofluorescence technique has to be adapted to the suspected virus infection on the basis of previous histopathology study. Variations of trypsin concentration time and temperature of incubation, expose different viral antigens and have to be previously tested for each unknown system. For measles virus detection in lung a stronger digestion has to be applied as compared to adenovirus or respiratory disease viruses in the same tisue. Flavivirus in liver tissue needs a weaker digestion. The reproducibility of the method makes it useful as a routine technique in diagnosis of virus infection.A presença de antígeno viral em cortes de tecidos humanos fixados em formol e emblocados em parafina foi demonstrada pela digestão com tripsina foi demonstrada pela ingestão com tripsina seguida de imunofluorescência direta ou indireta. Os espécimens podem ser utilizados para diagnoses retrospectivas. A técnica da imunofluorescência deve ser adaptada à infecção viral suspeita segundo diagnosie histopatológica prévia. Os parâmetros para a digestão do tecido pela tripsina, relacionados à concentração, duração de atuação e temperatura, expõem diferentes antígenos virais e devem ser previamente testados para cada sistema a ser estabelecido. Uma digestão mais intensa deve ser aplicada para a detecção do vírus do sarampo em tecido pulmonar do que para adenovírus ou vírus respiratório sincicial no mesmo tecido. Por outro lado, o vírus da febre amarela em tecido de fígado necessita de uma digestão mais fraca.

  10. AMP deaminase histochemical activity and immunofluorescent isozyme localization in rat skeletal muscle

    Science.gov (United States)

    Thompson, J. L.; Sabina, R. L.; Ogasawara, N.; Riley, D. A.

    1992-01-01

    The cellular distribution of AMP deaminase (AMPda) isozymes was documented for rat soleus and plantaris muscles, utilizing immunofluorescence microscopy and immunoprecipitation methods. AMPda is a ubiquitous enzyme existing as three distinct isozymes, A, B and C, which were initially purified from skeletal muscle, liver (and kidney), and heart, respectively. AMPda-A is primarily concentrated subsarcolemmally and intermyofibrillarly within muscle cells, while isozymes B and C are concentrated within non-myofiber elements of muscle tissue. AMPda-B is principally associated with connective tissues surrounding neural elements and the muscle spindle capsule, and AMPda-C is predominantly associated with circulatory elements, such as arterial and venous walls, capillary endothelium, and red blood cells. These specific localizations, combined with documented differences in kinetic properties, suggest multiple functional roles for the AMPda isozymes or temporal segregation of similar AMPda functions. Linkage of the AMPda substrate with adenosine production pathways at the AMP level and the localization of isozyme-C in vascular tissue suggest a regulatory role in the microcirculation.

  11. Semi-automated, occupationally safe immunofluorescence microtip sensor for rapid detection of Mycobacterium cells in sputum.

    Directory of Open Access Journals (Sweden)

    Shinnosuke Inoue

    Full Text Available An occupationally safe (biosafe sputum liquefaction protocol was developed for use with a semi-automated antibody-based microtip immunofluorescence sensor. The protocol effectively liquefied sputum and inactivated microorganisms including Mycobacterium tuberculosis, while preserving the antibody-binding activity of Mycobacterium cell surface antigens. Sputum was treated with a synergistic chemical-thermal protocol that included moderate concentrations of NaOH and detergent at 60°C for 5 to 10 min. Samples spiked with M. tuberculosis complex cells showed approximately 10(6-fold inactivation of the pathogen after treatment. Antibody binding was retained post-treatment, as determined by analysis with a microtip immunosensor. The sensor correctly distinguished between Mycobacterium species and other cell types naturally present in biosafe-treated sputum, with a detection limit of 100 CFU/mL for M. tuberculosis, in a 30-minute sample-to-result process. The microtip device was also semi-automated and shown to be compatible with low-cost, LED-powered fluorescence microscopy. The device and biosafe sputum liquefaction method opens the door to rapid detection of tuberculosis in settings with limited laboratory infrastructure.

  12. Spatial Mixture Modelling for Unobserved Point Processes: Examples in Immunofluorescence Histology.

    Science.gov (United States)

    Ji, Chunlin; Merl, Daniel; Kepler, Thomas B; West, Mike

    2009-12-04

    We discuss Bayesian modelling and computational methods in analysis of indirectly observed spatial point processes. The context involves noisy measurements on an underlying point process that provide indirect and noisy data on locations of point outcomes. We are interested in problems in which the spatial intensity function may be highly heterogenous, and so is modelled via flexible nonparametric Bayesian mixture models. Analysis aims to estimate the underlying intensity function and the abundance of realized but unobserved points. Our motivating applications involve immunological studies of multiple fluorescent intensity images in sections of lymphatic tissue where the point processes represent geographical configurations of cells. We are interested in estimating intensity functions and cell abundance for each of a series of such data sets to facilitate comparisons of outcomes at different times and with respect to differing experimental conditions. The analysis is heavily computational, utilizing recently introduced MCMC approaches for spatial point process mixtures and extending them to the broader new context here of unobserved outcomes. Further, our example applications are problems in which the individual objects of interest are not simply points, but rather small groups of pixels; this implies a need to work at an aggregate pixel region level and we develop the resulting novel methodology for this. Two examples with with immunofluorescence histology data demonstrate the models and computational methodology.

  13. Pattern of glomerular diseases in oman: A study based on light microscopy and immunofluorescence

    Directory of Open Access Journals (Sweden)

    Nasar Yousuf Alwahaibi

    2013-01-01

    Full Text Available Light microscopy and immunofluorescence play an important part in the final diagnosis of renal biopsy. The aim of this study was to analyze the pattern of various glomerular diseases in Oman. A total of 424 renal biopsies were retrospectively analyzed at the Sultan Qaboos University Hospital between 1999 and 2010. Focal and segmental glomerulosclerosis (FSGS, minimal change disease (MCD, membranous glomerulopathy (MGN and IgA nephropathy were the most common primary glomerular diseases encountered, accounting for 21.2%, 17%, 12.3% and 8.3%, respectively, of all cases. Lupus nephritis was the most common secondary glomerular disease and was the most prevalent among all biopsies, accounting for 30.4% of all biopsies. Amyloidosis was seen in only two cases. The presence of fluorescein isothiocyanatefibrin in all renal cases was low when compared with IgG, IgA, IgM, C3 and C1q markers. In conclusion, based on the findings of this study, lupus nephritis was the most common of all glomerular diseases and FSGS was the most common primary glomerular disease. The importance of fluorescein isothiocyanate-fibrin in the diagnosis of renal biopsy needs to be further investigated.

  14. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Science.gov (United States)

    Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J

    2017-01-01

    Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  15. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Directory of Open Access Journals (Sweden)

    Xavier Libert

    Full Text Available Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  16. Specific high-performance liquid chromatographic assay with ultraviolet detection for the determination of 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea in plasma.

    Science.gov (United States)

    Supko, J G; Phillips, L R; Malspeis, L

    1996-03-03

    A facile, sensitive and highly specific HPLC method for assaying 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea (SarCNU) in plasma has been developed. The drug was efficiently isolated from plasma by extraction with tert.-butyl methyl ether. A structurally related compound with similar physicochemical properties served as the internal standard (I.S.). Following evaporation of the organic solvent, the extract was reconstituted with 0.05 M ammonium acetate buffer, pH 5.0, and loaded onto a 4 micron Nova-Pak C18 column (15 cm x 3.9 mm), which was preceded by a 7 micron Brownlee RP-18 precolumn (1.5 cm x 3.2 mm). Chromatography was performed at ambient temperature using a mobile phase of methanol-0.1 M ammonium formate buffer, pH 3.7 (25:75, v/v). UV absorbance of the effluent was monitored at 240 nm. A flow-rate of 1.0 ml/ min was used for analyzing mouse and dog plasma extracts. Under these conditions, the drug eluted at 4.0 min and was followed by the I.S. at 6.1 min. An automatic switching valve was employed to allow the precolumn to be flushed 1.5 min into the run, without interrupting the flow of the mobile phase to the analytical column, thereby preventing the apparent build-up of extractable, strongly retained, UV-absorbing components present in mouse and dog plasma. Operating in this manner, more than 100 samples could be analyzed during a day using a refrigerated autosampler for overnight injection. The method was readily adapted to the determination of SarCNU in human plasma by simply decreasing the eluent flow-rate to 0.6 ml/min, whereby SarCNU and the I.S. eluted at approximately 5.8 and 9.1 min, respectively. Furthermore, the switching valve was not necessary for the analysis of human plasma samples. With a 50-microliter sample volume, the lowest concentration of SarCNU included in the plasma standard curves, 0.10 micrograms/ml, was quantified with a 7.8% R.S.D. (n = 27) over a 2 month period. Plasma standards, with concentrations of 0.26 to 5

  17. Characterization of pars intermedia connections in amphibians by biocytin tract tracing and immunofluorescence aided by confocal microscopy

    NARCIS (Netherlands)

    Jansen, K; Fabro, C; Artero, C; Feuilloley, M; Vaudry, H; Fasolo, A; Franzoni, MF

    Biocytin, recently introduced in neuroanatomical studies, was used as a retrograde tract tracer in combination with immunofluorescence in order to analyse the neurochemical characters of some central neuronal projections to the pars intermedia in two amphibian species, the anuran Rana esculenta and

  18. Detection of antinuclear antibodies by solid-phase immunoassays and immunofluorescence analysis

    DEFF Research Database (Denmark)

    Fenger, Mogens; Wiik, Allan; Høier-Madsen, Mimi

    2004-01-01

    -established rheumatic disorders, the newly developed EIA in which HEp-2 extracts were included had sensitivities and specificities comparable to or in some instances better than the IFA. The assays without HEp-2 extracts included had significantly lower sensitivities and specificities. In the outpatient population, up...... to 51% of patients had positive ANA tests that did not correspond to classic ANA-associated disease. However, in the assays in which the HEp-2 extracts were not included, the false-positive rate was ... and was mostly extracts included had a low sensitivity but a high specificity, particularly in nonselected populations. The choice of test is highly dependent on the clinical setting in which...

  19. Diagnostic performance of HPV E6/E7 mRNA assay for detection of cervical high-grade intraepithelial neoplasia and cancer among women with ASCUS Papanicolaou smears.

    Science.gov (United States)

    Ren, Chenchen; Zhu, Yuanhang; Yang, Li; Zhang, Xiaoan; Liu, Ling; Ren, Chunying

    2018-02-01

    The aim of this study was to investigate the clinical performance of high risk (HR) HPV E6/E7 mRNA assay in detecting cervical high-grade intraepithelial neoplasia and cancer among women with atypical squamous cells of undetermined significance (ASCUS) Papanicolaou (Pap) smears. A total of 160 patients with ASCUS who underwent HR-HPV DNA assay, HR-HPV E6/E7 mRNA assay and colposcopy biopsy at Third Affiliated Hospital of Zhengzhou University, China, from December 2015 to March 2017, were enrolled. Logistic regression analysis was used to evaluate the relationship between pathological results with clinical biologic factors. Univariate analysis showed that the qualitative results of HR-HPV DNA, qualitative results of HR-HPV E6/E7 mRNA and expression levels of HR-HPV E6/E7 mRNA were risk factors of high-grade cervical intraepithelial neoplasia (CIN) and cervical cancer (all P HPV E6/E7 mRNA was associated with high-grade CIN and cervical cancer (OR = 8.971, 95% CI = 2.572-31.289, P = 0.001). An optimal cut-off value of ≥ 558.26 copies/ml was determined using receiver operating characteristic curve, and specificity of cut-off value were higher than E6/E7 mRNA qualitative assay and DNA qualitative assay. HPV E6/E7 mRNA quantitative assay may be a valuable tool in triage of ASCUS pap smears. A high specificity of E6/E7 mRNA quantitative assay as a triage test in women with ASCUS can be translated into a low referral for colposcopy.

  20. Mistaken identity of an open reading frame proposed for PCR-based identification of Mycoplasma bovis and the effect of polymorphisms and insertions on assay performance

    Science.gov (United States)

    Mycoplasma bovis is an important cause of disease in cattle and bison. Because the bacterium requires specialized growth conditions many diagnostic laboratories routinely use PCR to replace or complement conventional isolation and identification methods. A frequently used target of such assays is th...

  1. Measurement of gene expression in archival paraffin-embedded tissues: development and performance of a 92-gene reverse transcriptase-polymerase chain reaction assay.

    Science.gov (United States)

    Cronin, Maureen; Pho, Mylan; Dutta, Debjani; Stephans, James C; Shak, Steven; Kiefer, Michael C; Esteban, Jose M; Baker, Joffre B

    2004-01-01

    Throughout the last decade many laboratories have shown that mRNA levels in formalin-fixed and paraffin-embedded (FPE) tissue specimens can be quantified by reverse transcriptase-polymerase chain reaction (RT-PCR) techniques despite the extensive RNA fragmentation that occurs in tissues so preserved. We have developed RT-PCR methods that are sensitive, precise, and that have multianalyte capability for potential wide use in clinical research and diagnostic assays. Here it is shown that the extent of fragmentation of extracted FPE tissue RNA significantly increases with archive storage time. Probe and primer sets for RT-PCR assays based on amplicons that are both short and homogeneous in length enable effective reference gene-based data normalization for cross comparison of specimens that differ substantially in age. A 48-gene assay used to compare gene expression profiles from the same breast cancer tissue that had been either frozen or FPE showed very similar profiles after reference gene-based normalization. A 92-gene assay, using RNA extracted from three 10- micro m FPE sections of archival breast cancer specimens (dating from 1985 to 2001) yielded analyzable data for these genes in all 62 tested specimens. The results were substantially concordant when estrogen receptor, progesterone receptor, and HER2 receptor status determined by RT-PCR was compared with immunohistochemistry assays for these receptors. Furthermore, the results highlight the advantages of RT-PCR over immunohistochemistry with respect to quantitation and dynamic range. These findings support the development of RT-PCR analysis of FPE tissue RNA as a platform for multianalyte clinical diagnostic tests.

  2. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    Science.gov (United States)

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  3. Review on the acute Daphnia magna toxicity test – Evaluation of the sensitivity and the precision of assays performed with organisms from laboratory cultures or hatched from dormant eggs

    Directory of Open Access Journals (Sweden)

    Persoone G.

    2009-08-01

    “Culture/maintenance free” aquatic microbiotests with species of different phylogenetic groups were developed in the early 1990s at the Laboratory for Environmental Toxicology and Aquatic Ecology at the Ghent University in Belgium. These assays which were given the generic name “Toxkits”, are unique in that they employ dormant stages (“cryptobiotic eggs” of the test species, which can be stored for long periods of time and “hatched” at the time of performance of the assays. One of these microbiotests is the Daphtoxkit F magna, which is currently used in many laboratories worldwide for research as well as for toxicity monitoring purposes. The microbiotest technology has several advantages in comparison to the “traditional” tests based on laboratory cultures, especially its independence of the stock culturing burden. However, the acceptance (or possible non-acceptance of performing assays with test organisms obtained from “dormant eggs” should be clearly dictated by the “sensitivity” and “precision” criteria of the former assays in comparison to the latter. The first part of this review therefore thoroughly reviews the scientific literature and of data obtained from various laboratories for assays performed with either D. magna test organisms obtained from lab cultures or hatched from dormant eggs. Attention has focused on data of quality control tests performed on reference chemicals, and in particular on potassium dichromate (K2Cr2O7 for which an acceptability range of 0.6–2.1 mg·L–1 has been set in ISO standard 6341 for the 24 h EC50 of the acute D. magna assay. Mean EC50s, standard deviations and variation coefficients were calculated from the collected data, all of which are presented in tables and figures and discussed in detail. The major conclusions drawn from the analysis of the large number of quality control (QC data on the acute D. magna toxicity test are that : (1 Virtually all results from assays performed with

  4. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  5. Comparison of two assays for detection of antibodies against canine parvovirus and canine distemper virus in dogs admitted to a Florida animal shelter.

    Science.gov (United States)

    Gray, Lauren K; Crawford, P Cynda; Levy, Julie K; Dubovi, Edward J

    2012-05-01

    To compare 2 assays for use in the identification of dogs with a protective antibody titer (PAT) against canine parvovirus (CPV) and canine distemper virus (CDV). Prospective cross-sectional study. 431 dogs admitted to a municipal animal shelter in north central Florida. Blood samples were collected from dogs on the day of admission to the shelter. Serum was obtained, criterion-referenced assays were used to identify dogs that had PATs against CPV (titers ≥ 80; hemagglutination inhibition assay) and CDV (titers ≥ 32; virus neutralization assay), and results were compared with results of a semiquantitative ELISA and an immunofluorescence assay (IFA). For correct identification of dogs that had PATs against viruses, the ELISA had significantly higher specificity for CPV (98%) and CDV (95%) than did the IFA (82% and 70%, respectively) and had significantly lower sensitivity for CDV (88%) than did the IFA (97%); the sensitivity for CPV was similar (ELISA, 98%; IFA, 97%). Overall diagnostic accuracy was significantly greater with the ELISA than with the IFA. Predictive value of a positive result for PATs was significantly higher with the ELISA for CPV (99%) and CDV (93%) than with the IFA (92% and 71%, respectively). The ELISA had fewer false-positive results than did the IFA and could be performed on-site in shelters in < 1 hour. Accuracy and practicality of the ELISA may be useful for identifying the infection risk of dogs exposed during outbreaks attributable to CPV and CDV infections in shelters.

  6. Reações de imunofluorescência indireta: algumas modificações de sua técnica Indirect immunofluorescence tests: some modifications of their technique

    Directory of Open Access Journals (Sweden)

    Cláudio Santos Ferreira

    1973-09-01

    Full Text Available Propõem-se modificações de procedimentos rotineiros de reações de imunofluorescência indireta. A eluição das amostras de sangue dessecado contidas em papel-filtro é feita em placas ("godets" com tampas. Alças de níquel-cromo substituem pipetas capilares para a transferência de amostras de eluatos para as lâminas de microscopia. Propõe-se uma técnica rápida e eficiente de lavagem das preparações.Some simplifications intended for routine operations included immunofluorescence tests are proposed. The elution of dried blood samples is performed on test plates (water-color mixing plates, with a lid instead of in test tubes. Nickel-chromium wire loops are substituted for capillary pipettes in transferring eluate samples to microscope slides. A rapid and efficient washing technique is proposed.

  7. Comparison between immunomagnetic separation, coupled with immunofluorescence, and the techniques of Faust et al. and of Lutz for the diagnosis of Giardia lamblia cysts in human feces

    Directory of Open Access Journals (Sweden)

    Souza Doris Sobral Marques

    2003-01-01

    Full Text Available In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA, was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

  8. Detection of Lawsonia intracellularis in formalin-fixed porcine intestinal tissue samples: comparison of immunofluorescence and in-situ hybridization, and evaluation of the effects of controlled autolysis.

    Science.gov (United States)

    Jensen, T K; Boesen, H T; Vigre, H; Boye, M

    2010-01-01

    Two methods, an immunofluorescence assay (IFA; with a Lawsonia intracellularis-specific monoclonal antibody) and fluorescent in-situ hybridization (FISH; with a specific oligonucleotide probe targeting 16S ribosomal RNA of the bacterium), were compared for their ability to detect L. intracellularis (the cause of porcine proliferative enteritis [PE]) in formalin-fixed samples of intestinal tissue. Of 69 intestinal samples with gross lesions of PE, 63 were positive by both FISH and IFA, but six were positive only by IFA. This indicated that the sensitivity of FISH was 91% that of IFA. However, both methods had a specificity of 100%. Fifty normal porcine intestines were negative by both tests. IFA was much less susceptible than FISH to the effects of autolysis. Thus, three of nine samples from pigs with PE were FISH-negative after being kept at 20 degrees C for 4 days, and seven were FISH negative after 2 weeks; after 4 weeks at this temperature, however, six of the nine samples were still IFA positive. After being kept at 4 degrees C for 12 weeks, the majority of samples (> or = 66%) were positive by both methods.

  9. Phytoplankton IF-FISH: Species-specific labeling of cellular proteins by immunofluorescence (IF) with simultaneous species identification by fluorescence immunohybridization (FISH).

    Science.gov (United States)

    Meek, Megan E; Van Dolah, Frances M

    2016-05-01

    Phytoplankton rarely occur as unialgal populations. Therefore, to study species-specific protein expression, indicative of physiological status in natural populations, methods are needed that will both assay for a protein of interest and identify the species expressing it. Here we describe a protocol for IF-FISH, a dual labeling procedure using immunofluorescence (IF) labeling of a protein of interest followed by fluorescence in situ hybridization (FISH) to identify the species expressing that protein. The protocol was developed to monitor expression of the cell cycle marker proliferating cell nuclear antigen (PCNA) in the red tide dinoflagellate, Karenia brevis, using a large subunit (LSU) rRNA probe to identify K. brevis in a mixed population of morphologically similar Karenia species. We present this protocol as proof of concept that IF-FISH can be successfully applied to phytoplankton cells. This method is widely applicable for the analysis of single-cell protein expression of any protein of interest within phytoplankton communities. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  11. Review on the acute Daphnia magna toxicity test – Evaluation of the sensitivity and the precision of assays performed with organisms from laboratory cultures or hatched from dormant eggs

    Directory of Open Access Journals (Sweden)

    G. Persoone

    2009-08-01

    Full Text Available One of the most internationally used bioassays for toxicity screening of chemicals and for toxicity monitoring of effluents and contaminated waters is the acute toxicity test with daphnid crustaceans, and in particular that performed with Daphnia magna.Standard methods have been developed for this assay that were gradually endorsed by national and international organisations dealing with toxicity testing procedures, in view of its application within a regulatory framework. As for all toxicity tests, the organisms used for the acute D. magna assay have to be obtained from live stocks which are cultured in the laboratory on live food (micro-algae.Unsurprisingly the various standard protocols of this particular assay differ – at least to a certain extent – with regard to the test organism culturing conditions. In addition, some technical aspects of the toxicity test such as the effect criterion (mortality of immobility, the exposure time, the type of dilution water, etc., also vary from one standard to another.Although this particular assay is currently used in many countries, the technical and biological problems inherent in year-round culturing and availability of the biological material and the culturing/maintenance costs of live stocks restrict its application to a limited number of highly specialised laboratories.This fundamental bottleneck in toxicity testing triggered investigations which brought forward the concept of “microbiotests” or “small-scale” toxicity tests. “Culture/maintenance free” aquatic microbiotests with species of different phylogenetic groups were developed in the early 1990s at the Laboratory for Environmental Toxicology and Aquatic Ecology at the Ghent University in Belgium.These assays which were given the generic name “Toxkits”, are unique in that they employ dormant stages (“cryptobiotic eggs” of the test species, which can be stored for long periods of time and “hatched” at the time of

  12. Sensitivity of direct immunofluorescence in oral diseases. Study of 125 cases.

    Science.gov (United States)

    Sano, Susana Mariela; Quarracino, María Cecilia; Aguas, Silvia Cristina; González, Ernestina Jesús; Harada, Laura; Krupitzki, Hugo; Mordoh, Ana

    2008-05-01

    Direct immunofluorescence (DIF) is widely used for the diagnosis of bullous diseases and other autoimmune pathologies such as oral lichen planus. There is no evidence in the literature on how the following variants influence the detection rate of DIF: intraoral site chosen for the biopsy, perilesional locus or distant site from the clinical lesion, number of biopsies and instrument used. to determine if the following variants influenced the sensitivity (detection rate): intraoral site chosen for the biopsy, perilesional or distant site from the clinical lesion, number of biopsies and instrument used (punch or scalpel). A retrospective study was done at the Cátedra de Patología y Clínica Bucodental II at the Facultad de Odontología, Universidad de Buenos Aires; 136 clinical medical histories were revised for the period March 2000 - March 2005 corresponding to patients with clinical diagnosis of OLP and bullous diseases (vulgar pemphigus, bullous pemphigoid and cicatricial pemphigoid). DIF detection rate was 65.8% in patients with OLP, 66.7% in cicatricial pemphigoid patients, in bullous pemphigoid 55.6%, in pemphigus vulgaris 100%, and in those cases in which certain diagnosis could not be obtained, the DIF positivity rate was 45.5% (Pearson chi(2) (4)= 21.5398 Pr= 0.000). There was no statistically significant difference between the different sites of biopsy (Fisher exact test: 0.825). DIF detection rate in perilesional biopsies was 66.1% and in those distant from the site of clinical lesion was 64.7% (Pearson chi(2) v1)= 0.0073 Pr= 0.932. When the number of biopsies were incremented, DIF detection rate also incremented (Pearson chi(2) = 8.7247 Pr= 0.003). The biopsies taken with punch had a higher detection rate than those taken with scalpel (39.1% versus 71.7%) (Pearson chi(2) = 49.0522 Pr= 0.000). While not statistically significant, the tendency outlined in this study indicates there are intraoral regions in which the detection rate of the DIF technique is

  13. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  14. Performance characteristics of a reverse transcriptase-polymerase chain reaction assay for the detection of tumor-specific fusion transcripts from archival tissue.

    Science.gov (United States)

    Fritsch, Michael K; Bridge, Julia A; Schuster, Amy E; Perlman, Elizabeth J; Argani, Pedram

    2003-01-01

    Pediatric small round cell tumors still pose tremendous diagnostic problems. In difficult cases, the ability to detect tumor-specific gene fusion transcripts for several of these neoplasms, including Ewing sarcoma/peripheral primitive neuroectodermal tumor (ES/PNET), synovial sarcoma (SS), alveolar rhabdomyosarcoma (ARMS), and desmoplastic small round cell tumor (DSRCT) using reverse transcriptase-polymerase chain reaction (RT-PCR), can be extremely helpful. Few studies to date, however, have systematically examined several different tumor types for the presence of multiple different fusion transcripts in order to determine the specificity and sensitivity of the RT-PCR method, and no study has addressed this issue for formalin-fixed material. The objectives of this study were to address the specificity, sensitivity, and practicality of such an assay applied strictly to formalin-fixed tissue blocks. Our results demonstrate that, for these tumors, the overall sensitivity for detecting each fusion transcript is similar to that reported in the literature for RT-PCR on fresh or formalin-fixed tissues. The specificity of the assay is very high, being essentially 100% for each primer pair when interpreting the results from visual inspection of agarose gels. However, when these same agarose gels were examined using Southern blotting, a small number of tumors also yielded reproducibly detectable weak signals for unexpected fusion products, in addition to a strong signal for the expected fusion product. Fluorescence in situ hybridization (FISH) studies in one such case indicated that a rearrangement that would account for the unexpected fusion was not present, while another case was equivocal. The overall specificity for each primer pair used in this assay ranged from 94 to 100%. Therefore, RT-PCR using formalin-fixed paraffin-embedded tissue sections can be used to detect chimeric transcripts as a reliable, highly sensitive, and highly specific diagnostic assay. However, we

  15. Evaluation of a Multiplex Real-Time Reverse Transcriptase PCR Assay for Detection and Differentiation of Influenza Viruses A and B during the 2001-2002 Influenza Season in Israel

    Science.gov (United States)

    Hindiyeh, Musa; Levy, Virginia; Azar, Roberto; Varsano, Noemi; Regev, Liora; Shalev, Yael; Grossman, Zehava; Mendelson, Ella

    2005-01-01

    The ability to rapidly diagnose influenza virus infections is of the utmost importance in the evaluation of patients with upper respiratory tract infections. It is also important for the influenza surveillance activities performed by national influenza centers. In the present study we modified a multiplex real-time reverse transcriptase PCR (RT-PCR) assay (which uses TaqMan chemistry) and evaluated it for its ability to detect and concomitantly differentiate influenza viruses A and B in 370 patient samples collected during the 2001-2002 influenza season in Israel. The performance of the TaqMan assay was compared to those of a multiplex one-step RT-PCR with gel detection, a shell vial immunofluorescence assay, and virus isolation in tissue culture. The TaqMan assay had an excellent sensitivity for the detection of influenza viruses compared to that of tissue culture. The overall sensitivity and specificity of the TaqMan assay compared to the results of culture were 98.4 and 85.5%, respectively. The sensitivity and specificity of the TaqMan assay for the detection of influenza virus A alone were 100 and 91.1%, respectively. On the other hand, the sensitivity and specificity for the detection of influenza virus B alone were 95.7 and 98.7%, respectively. The rapid turnaround time for the performance of the TaqMan assay (4.5 h) and the relatively low direct cost encourage the routine use of this assay in place of tissue culture. We conclude that the multiplex TaqMan assay is highly suitable for the rapid diagnosis of influenza virus infections both in well-established molecular biology laboratories and in reference clinical laboratories. PMID:15695650

  16. Application of indirect immunofluorescent test with an improved HEp-2 substrate tranfected with human Ro60/SSA autoantigens

    International Nuclear Information System (INIS)

    Lv Liangjing; Chen Shunle; Gu Yueying; Shen Nan; Bao Chunde; Wang Yuan; Xue Feng; Ye Peng; Yu Chongzhao

    2006-01-01

    To develop an improved substrate for indirect immunofluorescent test (IIF) to detect anti-Ro/SSA autoantibodies, the human 60-kDa Ro/SSA autoantigens (Ro60) cDNAs were obtained from placental cDNA library using PCR and were cloned into the mammalian expression vectorpEGFP-C1. Then the recombinant plasmids were transfected into HEp-2 cells. We con- firmed the overexpression, localization and antigenicity of fusion proteins in transfected cells by means of fluorescence microscopy, immunoblotting and IIF. HEp-2 and HEp-Ro60 was analyzed by IIF using a panel of 10 precipitinpositive anti-Ro human sera simultaneously. Stable expression of Ro60-GFP (green fluorescent protein) fusion proteins maintained ten more generations. And Ro60-GFP kept the antigenicity of Ro and had its own characteristic immunofluorescent pattern in HEp-Ro60 cells. The transfectants dramatically increased the sensitivity of IIF testing (a mean increase of 6.7-fold in endpoint titer, P<0.01). Eight (8/10) positive an- ti-Ro sera showed characteristic immunofluorescent pattern on HEp-Ro60, including two sera which were antinuclear antibodies (ANA) negative on untransfected HEp-2. IIF-ANA in all healthy sera were negative on HEp-Ro60. As a kind of new substrate of IIF, the Ro60 transfectants can be used to detect anti-Ro antibodies. In addition, transfected HEp-2 cells kept the immunofluorescent property of HEp-2 cells in IIF-ANA tests and could be employed as substrate for the routine IIF-ANA detection. The method improved the sensitivity of IIF-ANA. (authors)

  17. Evaluation and Comparison of Enzyme Immunoassay (Eia and Acid Fast Staining with Confirmation by Immunofluorescent Antibody Assay for Detection of Cryptosporidium Species in Infants and Young Children.

    Directory of Open Access Journals (Sweden)

    D Dorostcar Moghaddam

    2005-01-01

    Full Text Available Introduction: Cryptosporidiosis is prevalent world wide, causing a variety of problems ranging from acute, self-limiting diarrhea to fatal cases in immunocompromised persons, particulary those with acquired immunodeficiency (AIDS. Diagnosis of Cryptosporidium is made by identification of oocysts in stool specimens. The detection is most commonly made by the acid-fast staining method followed by microscopic examination which has low specificity and sensitivity. Material and Methods: In the present study, we evaluated diagnostic utility of a commercially available enzyme immunoassay (EIA, which detects Cryptosporidium-Specific antigen (CSA in 204 unprocessed stool specimens obtained from patients less than 3 years of age. Results: When compared with the routine screening procedure applied in this field study (screening by acid-fast staining and microscopy after concentration of positive results by IFA, both sensitivity and specificity were 98%. Of the 139 specimens negative by microscopy, 13 (9.3% were positive by EIA, 11 of which were confirmed by inhibition with antibody to Cryptosporidia-specific antigen. Conclusion: The EIA is an important tool for identifying Cryptosporidium in fecal specimens in field studies since it is sensitive, specific, simple to use and unaffected by the presence of a preservative.

  18. Detection of Streptococcus suis by in situ hybridization, indirect immunofluorescence, and peroxidase-antiperoxidase assays in formalin-fixed, paraffin-embedded tissue sections from pigs

    DEFF Research Database (Denmark)

    Boye, Mette; Feenstra, Anne Avlund; Tegtmeier, Conny

    2000-01-01

    and the immunohistochemical methods were used for detection of S. suis in formalin-fixed, paraffin-embedded tissue sections of brain, endocardium, and lung from pigs infected with S. suis. The methods developed were able to detect single cells of S. suis in situ in the respective samples, whereas no signal was observed from...

  19. Quantum Dots-Based Immunofluorescent Imaging of Stromal Fibroblasts Caveolin-1 and Light Chain 3B Expression and Identification of Their Clinical Significance in Human Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Honglei Chen

    2012-10-01

    Full Text Available Caveolin-1 (Cav-1 expression deficiency and autophagy in tumor stromal fibroblasts (hereafter fibroblasts are involved in tumor proliferation and progression, particularly in breast and prostate cancer. The aim of this study was to detect the expression of fibroblastic Cav-1 and LC3B, markers of autophagy, in gastric cancer (GC and to analyze their clinical significances. Furthermore, because Epstein-Barr virus (EBV-associated GC (EBVaGC is a unique subtype of GC; we compared the differential expression of fibroblastic Cav-1 and LC3B in EBVaGC and non-EBVaGC. Quantum dots (QDs-based immunofluorescence histochemistry was used to examine the expression of fibroblastic Cav-1 and LC3B in 118 cases of GC with adequate stroma. QDs-based double immunofluorescence labeling was performed to detect the coexpression of Cav-1 and LC3B proteins. EBV-encoded small RNA was detected by QDs-based fluorescence in situ hybridization to identify EBVaGC. Multivariate analysis indicated that low fibroblastic Cav-1 level was an independent prognosticator (p = 0.029 that predicted poorer survival of GC patients. Positive fibroblastic LC3B was correlated with lower invasion (p = 0.032 and was positively associated with Cav-1 expression (r = 0.432, p < 0.001. EBV infection did not affect fibroblastic Cav-1 and LC3B expression. In conclusion, positive fibroblastic LC3B correlates with lower invasion, and low expression of fibroblastic Cav-1 is a novel predictor of poor GC prognosis.

  20. A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT

    Directory of Open Access Journals (Sweden)

    Xuan Duc Nguyen

    2011-01-01

    Full Text Available Transfusion-related acute lung injury (TRALI is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT and granulocyte agglutination test (GAT were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1 and GAT (anti—HNA-2a, n = 1. The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of

  1. A novel tool for high-throughput screening of granulocyte-specific antibodies using the automated flow cytometric granulocyte immunofluorescence test (Flow-GIFT).

    Science.gov (United States)

    Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald

    2011-02-03

    Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.

  2. A Dual Microscopy-Based Assay To Assess Listeria monocytogenes Cellular Entry and Vacuolar Escape.

    Science.gov (United States)

    Quereda, Juan J; Pizarro-Cerdá, Javier; Balestrino, Damien; Bobard, Alexandre; Danckaert, Anne; Aulner, Nathalie; Shorte, Spencer; Enninga, Jost; Cossart, Pascale

    2016-01-01

    Listeria monocytogenes is a Gram-positive bacterium and a facultative intracellular pathogen that invades mammalian cells, disrupts its internalization vacuole, and proliferates in the host cell cytoplasm. Here, we describe a novel image-based microscopy assay that allows discrimination between cellular entry and vacuolar escape, enabling high-content screening to identify factors specifically involved in these two steps. We first generated L. monocytogenes and Listeria innocua strains expressing a β-lactamase covalently attached to the bacterial cell wall. These strains were then incubated with HeLa cells containing the Förster resonance energy transfer (FRET) probe CCF4 in their cytoplasm. The CCF4 probe was cleaved by the bacterial surface β-lactamase only in cells inoculated with L. monocytogenes but not those inoculated with L. innocua, thereby demonstrating bacterial access to the host cytoplasm. Subsequently, we performed differential immunofluorescence staining to distinguish extracellular versus total bacterial populations in samples that were also analyzed by the FRET-based assay. With this two-step analysis, bacterial entry can be distinguished from vacuolar rupture in a single experiment. Our novel approach represents a powerful tool for identifying factors that determine the intracellular niche of L. monocytogenes. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  3. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  4. Performance of a Highly Sensitive Mycobacterium tuberculosis Complex Real-Time PCR Assay for Diagnosis of Pulmonary Tuberculosis in a Low-Prevalence Setting: a Prospective Intervention Study.

    Science.gov (United States)

    Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David

    2018-05-01

    The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.

  5. Development of a stability-indicating high performance liquid chromatography method for assay of erythromycin ethylsuccinate in powder for oral suspension dosage form

    Directory of Open Access Journals (Sweden)

    Fahimeh Kamarei

    2014-12-01

    Full Text Available In this study an effective method was developed to assay erythromycin ethylsuccinate for an oral suspension dosage form. The chromatographic separation was achieved on an X-Terra™ C18 analytical column. A mixture of acetonitrile–ammonium dihydrogen phosphate buffer (0.025 mol L-1 (60:40, V/V (pH 7.0 was used as the mobile phase, effluent flow rate monitored at 1.0 mL min−1, and UV detection at 205 nm. In forced degradation studies, the effects of acid, base, oxidation, UV light and temperature were investigated showing no interference in the peak of drug. The proposed method was validated in terms of specificity, linearity, robustness, precision and accuracy. The method was linear at concentrations ranging from 400 to 600 μg mL−1, precise (intra- and inter-day relative standard deviations <0.65, accurate (mean recovery; 99.5%. The impurities and degradation products of erythromycin ethylsuccinate were selectively determined with good resolution in both the raw material and the final suspension forms. The method could be useful for both routine analytical and quality control assays of erythromycin ethylsuccinate in commercial powder for an oral suspension dosage form and it could be a very powerful tool to investigate the chemical stability of erythromycin ethylsuccinate.

  6. Myoblots: dystrophin quantification by in-cell western assay for a streamlined development of Duchenne muscular dystrophy (DMD) treatments.

    Science.gov (United States)

    Ruiz-Del-Yerro, E; Garcia-Jimenez, I; Mamchaoui, K; Arechavala-Gomeza, V

    2017-10-31

    New therapies for neuromuscular disorders are often mutation specific and require to be studied in patient's cell cultures. In Duchenne muscular dystrophy (DMD) dystrophin restoration drugs are being developed but as muscle cell cultures from DMD patients are scarce and do not grow or differentiate well, only a limited number of candidate drugs are tested. Moreover, dystrophin quantification by western blotting requires a large number of cultured cells; so fewer compounds are as thoroughly screened as is desirable. We aimed to develop a quantitative assessment tool using fewer cells to contribute in the study of dystrophin and to identify better drug candidates. An 'in-cell western' assay is a quantitative immunofluorescence assay performed in cell culture microplates that allows protein quantification directly in culture, allowing a higher number of experimental repeats and throughput. We have optimized the assay ('myoblot') to be applied to the study of differentiated myoblast cultures. After an exhaustive optimization of the technique to adapt it to the growth and differentiation rates of our cultures and the low intrinsic expression of our proteins of interests, our myoblot protocol allows the quantification of dystrophin and other muscle-associated proteins in muscle cell cultures. We are able to distinguish accurately between the different sets of patients based on their dystrophin expression and detect dystrophin restoration after treatment. We expect that this new tool to quantify muscle proteins in DMD and other muscle disorders will aid in their diagnosis and in the development of new therapies. © 2017 British Neuropathological Society.

  7. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  8. Performance of four different indirect enzyme-linked immunosorbent assays (ELISAs) to detect specific IgG, IgA, and IgM in Legionnaires' disease

    DEFF Research Database (Denmark)

    Bangsborg, Jette Marie; Shand, G H; Hansen, K

    1994-01-01

    Currently recommended methods in Legionnaires' disease serology are based upon crude whole-cell antigenic preparations. To investigate whether purified antigens would perform better in a given diagnostic test for antibodies against Legionella pneumophila, we compared the performance of three...

  9. Development and evaluation of the performance of a computer program for the quality control of radioligant assays, application to the radioassay of insulin

    International Nuclear Information System (INIS)

    Mesquita, C.H. de.

    1983-01-01

    A computer program was developed to evaluate several parameters of in radioligant assays. The program was written in FORTRAN-IV having a modular structure. The present version is designed to compute a number of parameters pertinent to the activities of the radioassays. The standard curve is fitted to the empirical model which has four parameters following Marquardt i-iterative scheme. The curve is weighted according to Rodbard criterion. The mini mum detectable dose (MDD) is estimated by a criterion which considers the standard deviation of the experimental data measured with respect to the zero concentration, theoretically computed by the power function. This function considers the standard deviations of all samples and standards being assayed. The Scatchard plot is drawn for one binding component, but it is suitable for up to five components including that nonspecific and non saturated one. The specific activity is computed by the self-displacement method including the corrections suggested by Morris. The computer program processes data pertinent to the thermodynamic analysis through the incubation temperature and its respective reaction affinity constant 'K'. Starting from the estimated enthalpy and entropy of the reaction, the program produces theoretical standard curves for any level of incubation temperature. This allows the analyst to select the interval which best attends the dosage needs. Other general data pertinent to the radioisotope methodology can also be processed by the present program, such as radiochromatogram analysis chi-square test and the estimate the error during the procedures of pipetting. In order to demonstrate the use and the quality of the informations given by the program, a radioimmunoassay of insulin was carried out. The results obtained are in good agreement with those found in the literature. (Author) [pt

  10. STANDARDIZATION OF A FLUORESCENT-BASED QUANTITATIVE ADHESION ASSAY TO STUDY ATTACHMENT OF Taenia solium ONCOSPHERE TO EPITHELIAL CELLS In Vitro

    Science.gov (United States)

    Chile, Nancy; Evangelista, Julio; Gilman, Robert H.; Arana, Yanina; Palma, Sandra; Sterling, Charles R; Garcia, Hector H.; Gonzalez, Armando; Verastegui, Manuela

    2012-01-01

    To fully understand the preliminary stages of Taenia solium oncosphere attachment in the gut, adequate tools and assays are necessary to observe and quantify this event that leads to infection. A fluorescent-based quantitative adhesion assay, using biotinylated activated-oncospheres and monolayers of Chinese hamster ovary cells (CHO-K1) or human intestinal monolayer cells (INT-407, HCT-8 or HT-29), was developed to study initial events during the infection of target cells and to rapidly quantify the in vitro adhesion of T. solium oncospheres. Fluorescein streptavidin was used to identify biotinylated activated-oncospheres adhered to cells. This adherence was quantified using an automated fluorescence plate reader, and the results were expressed as fluorescence intensity values. A series of three assays were performed. The first was to identify the optimum number of biotinylated activated-oncospheres to be used in the adhesion assay. The goal of the second assay was to validate this novel method with the established oncosphere-binding system using the immunofluorescent-antibody assay (IFA) method to quantify oncosphere adhesion. A total of 10,000 biotinylated activated-oncospheres were utilized to assess the role of sera and laminin (LM) in oncosphere adherence to a CHO-K1 cell monolayer. The findings that sera and LM increase the adhesion of oncospheres to monolayer cells were similar to results that were previously obtained using the IFA method. The third assay compared the adherence of biotinylated activated-oncospheres to different types of human intestinal monolayer cells. In this case, the fluorescence intensity was greatest when using the INT-407 cell monolayer. We believe this new method of quantification offers the potential for rapid, large-scale screening to study and elucidate specific molecules and mechanisms involved in oncosphere-host cell attachment. PMID:22178422

  11. Immunofluorescent detection in the ovary of host antibodies against a secretory ferritin injected into female Haemaphysalis longicornis ticks.

    Science.gov (United States)

    Galay, Remil Linggatong; Matsuo, Tomohide; Hernandez, Emmanuel Pacia; Talactac, Melbourne Rio; Kusakisako, Kodai; Umemiya-Shirafuji, Rika; Mochizuki, Masami; Fujisaki, Kozo; Tanaka, Tetsuya

    2018-04-01

    Due to the continuous threat of ticks and tick-borne diseases to human and animal health worldwide, and the drawbacks of chemical acaricide application, many researchers are exploring vaccination as an alternative tick control method. Earlier studies have shown that host antibodies can circulate in the ticks, but it has not been confirmed whether these antibodies can be passed on to the eggs. We previously reported that ticks infesting rabbits immunized with a recombinant secretory ferritin of Haemaphysalis longicornis (HlFER2) had reduced egg production and hatching. Here we attempted to detect the presence of antibodies against HlFER2 in the ovary and eggs of female ticks through immunofluorescent visualization. Purified anti-HlFER2 antibodies or rabbit IgG for control was directly injected to engorged female H. longicornis. Ovaries and eggs after oviposition were collected and prepared for an indirect immunofluorescent antibody test. Positive fluorescence was detected in ovaries one day post-injection of anti-HlFER2 antibodies. Through silencing of Hlfer2 gene, we also determined whether the injected antibodies can specifically bind to native HlFER2. Immunofluorescence was observed in the oocytes of dsLuciferase control ticks injected with anti-HlFER2 antibodies, but not in the oocytes of Hlfer2-silenced ticks also injected with anti-HlFER2 antibodies. Our current findings suggest that host antibodies can be passed on to the oocytes, which is significant in formulating a vaccine that can disrupt tick reproduction. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Hepatitis B Core Antigen in Hepatocytes of Chronic Hepatitis B: Comparison between Indirect Immunofluorescence and Immunoperoxidase Method

    Science.gov (United States)

    Tabassum, Shahina; Al-Mahtab, Mamun; Nessa, Afzalun; Jahan, Munira; Shamim Kabir, Chowdhury Mohammad; Kamal, Mohammad; Cesar Aguilar, Julio

    2015-01-01

    Background Hepatitis B virus (HBV) infection has many faces. Precore and core promoter mutants resemble inactive carrier status. The identification of hepatitis B core antigen (HBcAg) in hepatocytes may have variable clinical significance. The present study was undertaken to detect HBcAg in chronic hepatitis B (CHB) patients and to assess the efficacy of detection system by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP). Materials and methods The study was done in 70 chronic HBV-infected patients. Out of 70 patients, eight (11.4%) were hepatitis B e antigen (HBeAg) positive and 62 (88.57%) were HBeAg negative. Hepatitis B core antigen was detected by indirect immunofluorescence (IIF) and indirect immunoperoxidase (IIP) methods in liver tissue. Results All HBeAg positive patients expressed HBcAg by both IIF and IIP methods. Out of 62 patients with HBeAg-negative CHB, HBcAg was detected by IIF in 55 (88.7%) patients and by IIP in 51 (82.26%) patients. A positive relation among viral load and HBcAg detection was also found. This was more evident in the case of HBeAg negative patients and showed a positive relation with HBV DNA levels. Conclusion Hepatitis B core antigen can be detected using the IIF from formalin fixed paraffin block preparation and also by IIP method. This seems to reflect the magnitudes of HBV replication in CHB. How to cite this article Raihan R, Tabassum S, Al-Mahtab M, Nessa A, Jahan M, Kabir CMS, Kamal M, Aguilar JC. Hepatitis B Core Antigen in Hepatocytes of Chronic Hepatitis B: Comparison between Indirect Immunofluorescence and Immunoperoxidase Method. Euroasian J Hepato-Gastroenterol 2015;5(1):7-10. PMID:29201677

  13. Application of photostable quantum dots for indirect immunofluorescent detection of specific bacterial serotypes on small marine animals

    International Nuclear Information System (INIS)

    Decho, Alan W; Beckman, Erin M; Chandler, G Thomas; Kawaguchi, Tomohiro

    2008-01-01

    An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae

  14. Quantum-dot-based immunofluorescent imaging of HER2 and ER provides new insights into breast cancer heterogeneity

    International Nuclear Information System (INIS)

    Chen Chuang; Li Yan; Peng Jun; Xu Hao; Tang Hongwu; Zhang Zhiling; Pang Daiwen; Xia Heshun; Wu Qiongshui; Zeng Libo; Zhu Xiaobo

    2010-01-01

    Breast cancer (BC) is a heterogeneous tumor, and better understanding of its heterogeneity is essential to improving treatment effect. Quantum dot (QD)-based immunofluorescent nanotechnology (QD-IHC) for molecular pathology has potential advantages in delineating tumor heterogeneity. This potential is explored in this paper by QD-IHC imaging of HER2 and ER. BC heterogeneity can be displayed more clearly and sensitively by QD-IHC than conventional IHC in BC tissue microarrays. Furthermore, the simultaneous imaging of ER and HER2 might help understand their interactions during the process of evolution of heterogeneous BC.

  15. Simultaneous detection of five different 2-hydroxyethyl-DNA adducts formed by ethylene oxide exposure, using a high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry assay.

    Science.gov (United States)

    Tompkins, Elaine M; Jones, Donald J L; Lamb, John H; Marsden, Debbie A; Farmer, Peter B; Brown, Karen

    2008-01-01

    A method has been developed for the simultaneous detection and quantitation of five different 2-hydroxyethyl-DNA (HE-DNA) adducts that could be formed as a result of exposure to ethylene oxide (EO). In addition to the major N7-HE-guanine (N7-HEG) adducts this assay can also measure the less prevalent but potentially more biologically significant N1-HE-2'-deoxyadenosine (N1-HEdA), O(6)-HE-2'-deoxyguanosine (O(6)-HEdG), N(6)-HE-2'-deoxyadenosine (N(6)-HEdA) and N3-HE-2'-deoxyuridine adducts (N3-HEdU). The method involves the isolation of HE adducts from the unmodified nucleosides by either neutral thermal hydrolysis or enzymatic digestion, followed by high-performance liquid chromatographic (HPLC) purification, before detection and quantification by liquid chromatography tandem mass spectrometry (LC/MS/MS) using selective reaction monitoring (SRM). The limits of detection were in the range 0.5-25 fmol for each individual adduct, making this one of the most sensitive assays available for the detection of N7-HEG. To illustrate the possible applications of the assay, it has been employed in the measurement of endogenous/background and EO-induced HE adducts in a variety of DNA samples.

  16. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  17. First 25-hydroxyvitamin D assay for general chemistry analyzers.

    Science.gov (United States)

    Saida, Fakhri B; Chen, Xiaoru; Tran, Kiet; Dou, Chao; Yuan, Chong

    2015-03-01

    25-Hydroxyvitamin D [25(OH)D], the predominant circulating form of vitamin D, is an accurate indicator of the general vitamin D status of an individual. Because vitamin D deficiencies have been linked to several pathologies (including osteoporosis and rickets), accurate monitoring of 25(OH)D levels is becoming increasingly important in clinical settings. Current 25(OH)D assays are either chromatographic or immunoassay-based assays. These assays include HPLC, liquid chromatography-tandem mass spectrometry (LC-MS/MS), enzyme-immunosorbent, immunochemiluminescence, immunofluorescence and radioimmunoassay. All these assays use heterogeneous formats that require phase separation and special instrumentations. In this article, we present an overview of these assays and introduce the first homogeneous assay of 25(OH)D for use on general chemistry analyzers. A special emphasis is put on the unique challenges posed by the 25(OH)D analyte. These challenges include a low detection limit, the dissociation of the analyte from its serum transporter and the inactivation of various binding proteins without phase separation steps.

  18. Assay optimization for molecular detection of Zika virus

    NARCIS (Netherlands)

    Corman, Victor M.; Rasche, Andrea; Baronti, Cecile; Aldabbagh, Souhaib; Cadar, Daniel; Reusken, Chantal Bem; Pas, Suzan D.; Goorhuis, Abraham; Schinkel, Janke; Molenkamp, Richard; Kümmerer, Beate M.; Bleicker, Tobias; Brünink, Sebastian; Eschbach-Bludau, Monika; Eis-Hübinger, Anna M.; Koopmans, Marion P.; Schmidt-Chanasit, Jonas; Grobusch, Martin P.; de Lamballerie, Xavier; Drosten, Christian; Drexler, Jan Felix

    2016-01-01

    To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection. We compared seven published real-time RT-PCR assays and two new assays that we have developed. To determine the analytical sensitivity of each assay, we

  19. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.

    Science.gov (United States)

    Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90

  20. Double-label immunofluorescence method for simultaneous detection of adenovirus and herpes simplex virus from the eye.

    Science.gov (United States)

    Walpita, P; Darougar, S

    1989-07-01

    The development and application of a double-label immunofluorescence method which has the potential to screen for single or dual infections from any site, in single shell vial cultures, is described. In this study, a total of 1,141 ocular specimens were inoculated in shell vials, centrifuged at 15,000 X g for 1 h, incubated at 37 degrees C for 48 h, and fixed in methanol at room temperature for 15 min. The virus inclusions were detected by staining with a double-label indirect immunofluorescence procedure using mixtures of appropriate first antibodies, followed by fluorescein- and rhodamine-conjugated second antibodies. Each specimen was also inoculated in parallel by the conventional virus isolation method. The sensitivity and specificity of the double-label shell vial procedure were comparable to those with the conventional method, and the former test took only 48 h to complete. The test offers a rapid and simple single-vial procedure which allows for individual or simultaneous detection of multiple pathogens. It results in savings in time and cost over the conventional virus isolation method and other shell vial procedures.

  1. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  2. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  3. Validation of tumor protein marker quantification by two independent automated immunofluorescence image analysis platforms

    Science.gov (United States)

    Peck, Amy R; Girondo, Melanie A; Liu, Chengbao; Kovatich, Albert J; Hooke, Jeffrey A; Shriver, Craig D; Hu, Hai; Mitchell, Edith P; Freydin, Boris; Hyslop, Terry; Chervoneva, Inna; Rui, Hallgeir

    2016-01-01

    Protein marker levels in formalin-fixed, paraffin-embedded tissue sections traditionally have been assayed by chromogenic immunohistochemistry and evaluated visually by pathologists. Pathologist scoring of chromogen staining intensity is subjective and generates low-resolution ordinal or nominal data rather than continuous data. Emerging digital pathology platforms now allow quantification of chromogen or fluorescence signals by computer-assisted image analysis, providing continuous immunohistochemistry values. Fluorescence immunohistochemistry offers greater dynamic signal range than chromogen immunohistochemistry, and combined with image analysis holds the promise of enhanced sensitivity and analytic resolution, and consequently more robust quantification. However, commercial fluorescence scanners and image analysis software differ in features and capabilities, and claims of objective quantitative immunohistochemistry are difficult to validate as pathologist scoring is subjective and there is no accepted gold standard. Here we provide the first side-by-side validation of two technologically distinct commercial fluorescence immunohistochemistry analysis platforms. We document highly consistent results by (1) concordance analysis of fluorescence immunohistochemistry values and (2) agreement in outcome predictions both for objective, data-driven cutpoint dichotomization with Kaplan–Meier analyses or employment of continuous marker values to compute receiver-operating curves. The two platforms examined rely on distinct fluorescence immunohistochemistry imaging hardware, microscopy vs line scanning, and functionally distinct image analysis software. Fluorescence immunohistochemistry values for nuclear-localized and tyrosine-phosphorylated Stat5a/b computed by each platform on a cohort of 323 breast cancer cases revealed high concordance after linear calibration, a finding confirmed on an independent 382 case cohort, with concordance correlation coefficients >0

  4. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  5. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  6. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  7. High-performance thin-layer chromatography linked with (bio)assays and mass spectrometry - a suited method for discovery and quantification of bioactive components? Exemplarily shown for turmeric and milk thistle extracts.

    Science.gov (United States)

    Taha, Mahmoud N; Krawinkel, Michael B; Morlock, Gertrud E

    2015-05-15

    Extraction parameters, chemical fingerprint, and the single compounds' activity levels were considered for the selection of active botanicals. For an initial survey, the total bioactivity (i.e., total reducing capacity, total flavonoids contents and free radical scavenging capacity) of 21 aqueous and 21 ethanolic plant extracts was investigated. Ethanolic extracts showed a higher yield and were further analyzed by HPTLC in detail to obtain fingerprints of single flavonoids and further bioactive components. Exemplarily shown for turmeric (Curcuma longa) and milk thistle (Silybum marianum), effect-directed analysis (EDA) was performed using three selected (bio)assays, the Aliivibrio fischeri bioassay, the Bacillus subtilis bioassay and the 2,2-diphenyl-1-picrylhydrazyl (DPPH*) assay. As a proof of principle, the bioactive components found in the extracts were confirmed by HPTLC-MS. Bioassays in combination with planar chromatography directly linked to the known, single effective compounds like curcumin and silibinin. However, also some unknown bioactive components were discovered and exemplarily characterized, which demonstrated the strength of this kind of EDA. HPTLC-UV/Vis/FLD-EDA-MS could become a useful tool for selection of active botanicals and for the activity profiling of the active ingredients therein. The flexibility in effect-directed detections allows a comprehensive survey of effective ingredients in samples. This streamlined methodology comprised a non-targeted, effect-directed screening first, followed by a highly targeted characterization of the discovered bioactive compounds. HPTLC-EDA-MS can also be recommended for bioactivity profiling of food on the food intake side, as not only effective phytochemicals, but also unknown bioactive degradation products during food processing or contamination products or residues or metabolites can be detected. Thus, an efficient survey on potential food intake effects on wellness could be obtained. Having performed

  8. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    Science.gov (United States)

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  9. Practical application of immunofluorescence for the detection of bacterial contaminants during vinification

    Directory of Open Access Journals (Sweden)

    Marielle Bouix

    1997-03-01

    Full Text Available This study presents a rapid and specific microscopie technique for detecting and identifying populations of lactic acid bacteria in musts, wines, and inoculum starter cultures. Through the use of fluorescent antibodies, this procedure can be performed in less than two hours, and it is effective with Leuconostoc, Pediococcus and Lactobacillus concentrations as small as 102 cells/ml. Implementation of this technique will assist winemakers in controlling malolactic fermentations and in preventing lactic acid bacterial spoilage.

  10. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  11. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  12. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values

    DEFF Research Database (Denmark)

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G

    2016-01-01

    BACKGROUND: The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally...... done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CVA): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian....... METHODS: The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical...

  13. Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay

    NARCIS (Netherlands)

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-01-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0

  14. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  15. Performance of a commercial assay for the diagnosis of influenza A (H1N1 infection in comparison to the Centers for Disease Control and Prevention protocol of real time RT-PCR

    Directory of Open Access Journals (Sweden)

    María G Barbás

    2012-03-01

    Full Text Available At the time of influenza A (H1N1 emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR. The aim of the present study was to evalúate the performance of the "Real Time Ready Influenza A/H1N1 Detection Set" (June 2009-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009 is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays.Durante la pandemia de influenza A (H1N1, la OMS recomendó algoritmos y protocolos de detección del virus mediante RT-PCR en tiempo real. El objetivo del presente estudio fue evaluar el desempeño del equipo que comercializa la empresa Roche, Real Time Ready Influenza A/H1N1 Detection Set (junio de 2009, en comparación con el protocolo de RT-PCR en tiempo real de los CDC. La sensibilidad global del ensayo de Roche para la detección del gen Inf A en presencia o ausencia del gen H1 fue 74,5 %. La sensibilidad para la detección de muestras positivas solo para el gen Inf A (ausencia del gen H1 fue 53,3 % y la sensibilidad para la detección de muestras positivas para H1N1 (presencia del gen Inf A y cualquier otro gen porcino fue 76,4 %. La especificidad fue 97,1 %. Existe una nueva versión del equipo (noviembre 2009 que, según se ha descrito, presenta buena sensibilidad en comparación con otros ensayos moleculares para detectar H1N1 pandémica.

  16. A comparison of indirect immunofluorescence and electron microscopy for the diagnosis of some haemorrhagic viruses in cell cultures.

    Science.gov (United States)

    El Mekki, A A; van der Groen, G

    1981-09-01

    Yellow fever, dengue (types 1, 2 and 4), Chikungunya, Rift Valley fever, Ebola, Marburg, and Lassa viruses were inoculated into susceptible cell cultures and daily investigated by indirect immunofluorescence (IFA) and electron microscopy (EM) with a view to achieve an early detection-identification of these agents. Compared to the other cell lines tested (Vero, BHK-21 and Aedes albopictus), CV-1 cells were found to be more sensitive. Viral antigens were detected by IFA from a few hours post inoculation (CHIK and RVF) to a maximum of 3 days (YF and EBO). For most of the viruses studied, the cytopathic effect (CPE) commenced 2-3 days after the detection of viral antigens. Virus particles were detected by EM only in the case of EBO, MBG and LAS, before any CPE was observed in cell cultures.

  17. Comparison of immunofluorescence investigations and a new anti-DNA-antibody radioimmunoassay for the diagnosis of connective tissue diseases

    International Nuclear Information System (INIS)

    Neumeier, D.; Vogt, W.; Knedel, M.

    1976-01-01

    The procedure of determining the anti-DNA antibody activity is simplified by high-molecular double strand DNA labelled with 125 I. Cases of suspected connective tissue disease should first be examined by immunofluorescence microscopy, since this method can detect a wider spectrum of diseases with similar symptoms. For a differential diagnosis of SLE, the anti-DNA antibody activity is then investigated by a radioimmunoassay. When assessing the antibody activity, the following criteria should be kept in mind: - Findings of less than 10 units/ml serum do not indicate pathological changes, - Higher antibody activities up to 35 units/ml serum may occur in SLE patients but are also possible in other ANA positive diseases with similar symptoms, - Activities over 35 units/ml serum are nearly always a sign of SLE. (orig./GSE) [de

  18. Comparison of immunofluorescence investigations and a new anti-DNA-antibody radioimmunoassay for the diagnosis of connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Neumeier, D; Vogt, W; Knedel, M

    1976-01-01

    The procedure of determining the anti-DNA antibody activity is simplified by high-molecular double strand DNA labelled with /sup 125/I. Cases of suspected connective tissue disease should first be examined by immunofluorescence microscopy, since this method can detect a wider spectrum of diseases with similar symptoms. For a differential diagnosis of SLE, the anti-DNA antibody activity is then investigated by a radioimmunoassay. When assessing the antibody activity, the following criteria should be kept in mind: - Findings of less than 10 units/ml serum do not indicate pathological changes, - Higher antibody activities up to 35 units/ml serum may occur in SLE patients but are also possible in other ANA positive diseases with similar symptoms, - Activities over 35 units/ml serum are nearly always a sign of SLE.

  19. Exploitation of immunofluorescence for the quantification and characterization of small numbers of Pasteuria endospores.

    Science.gov (United States)

    Costa, Sofia R; Kerry, Brian R; Bardgett, Richard D; Davies, Keith G

    2006-12-01

    The Pasteuria group of endospore-forming bacteria has been studied as a biocontrol agent of plant-parasitic nematodes. Techniques have been developed for its detection and quantification in soil samples, and these mainly focus on observations of endospore attachment to nematodes. Characterization of Pasteuria populations has recently been performed with DNA-based techniques, which usually require the extraction of large numbers of spores. We describe a simple immunological method for the quantification and characterization of Pasteuria populations. Bayesian statistics were used to determine an extraction efficiency of 43% and a threshold of detection of 210 endospores g(-1) sand. This provided a robust means of estimating numbers of endospores in small-volume samples from a natural system. Based on visual assessment of endospore fluorescence, a quantitative method was developed to characterize endospore populations, which were shown to vary according to their host.

  20. Diagnóstico de criptosporidiose em amostras fecais de bezerros por imunofluorescência direta e microscopia de contraste de fase Diagnosis of cryptosporidiosis in fecal samples of calves using direct immunofluorescence and phase contrast microscopy

    Directory of Open Access Journals (Sweden)

    Weslen Fabricio Pires Teixeira

    2011-06-01

    Full Text Available O presente estudo teve como objetivo comparar as técnicas de imunofluorescência direta (IFD e a microscopia de contraste de fase em solução de Sheather (MCF, para detecção de oocistos de Cryptosporidium spp. em amostras fecais de bezerros. A determinação dos limiares detecção da IFD e da MCF foi realizada utilizando cinco alíquotas de uma amostra fecal de bezerro, comprovadamente negativa para Cryptosporidium spp., adicionadas com diferentes quantidades de oocistos de Cryptosporidium parvum. Ao exame das 5 alíquotas, a IFD e a MCF apresentaram, respectivamente, limiares de detecção de 3,3x104 (duas alíquotas positivas e 3,3x105 oocistos (1 alíquota positiva por grama de fezes. Foram também realizadas a comparação entre a positividade obtida e uma análise semiquantitativa do número de oocistos observados por campo de microscopia, em ambos os métodos, em 300 amostras fecais de bezerros. Entre as 300 amostras, 19,7% (59/300 foram positivas pela IFD, com diferença estatisticamente significante (P=0,0098 quando comparada com a positividade obtida pela MCF, que foi de 11,7% (35/300. As amostras positivas foram submetidas à reação em cadeia da polimerase para amplificação de fragmentos da subunidade 18S do rRNA, com posterior sequenciamento dos fragmentos amplificados, o que permitiu a identificação de Cryptosporidium andersoni em 11,9% (7/59 e de C.parvum em 88,1% (52/59 das amostras. Os resultados observados comprovam que a IFD foi mais eficiente que a MCF para detecção de oocistos de Cryptosporidium spp. em amostras fecais de bezerros.This study aimed to compare the direct immunofluorescence assay (DIF and the phase contrast microscopy in Sheather solution (PCM for detection of Cryptosporidium oocysts in fecal samples from calves. The determination of the thresholds of detection of DIF and PCM was performed using five aliquots of a fecal sample from a calf negative for Cryptosporidium spp. oocysts, spiked with

  1. Desarrollo de improntas para el diagnóstico del virus Epstein-Barr por inmunofluorescencia indirecta Development of slides for Epstein-Barr virus diagnosis by indirect immunofluorescence

    Directory of Open Access Journals (Sweden)

    Germán R. Pérez

    2005-08-01

    mononucleosis. Detection of anti-viral capside antigen (VCA antibodies indicates previous or present EBV infection. Moreover, high titles of anti-VCA antibodies are observed in EBV-associated neoplasic disorders, such as lymphomas in AIDS patients. The objective of this study was the development and optimization of P3HR1 cell slides for the EBV serologic detection by indirect immunofluorescence (IIF assay. P3HR1 exponential growth culture cells were stimulated with phorbol-12-mirystoil-13-acetate, collected at different time points and used for slide preparation. IIF assay was performed in each slide using an anti-EBV positive serum as primary antibody. An 11% increase in VCA expression was observed at 40 hours post-stimulation. Data was confirmed by western blot and immunodetection. Intra- and inter-lot precisions of the developed slides were evaluated for IgG and IgM antibodies using EBV-positive sera and positive samples for other members of the Herpesviridae family. Neither false-positive or false negative results were obtained for EBV detection nor cross-reaction was observed with other members of the Herpesviridae family with the developed slides. In conclusion, the slides here presented can be a useful instrument for acute EBV infection diagnosis and for the serologic detection of IgG anti-VCA antibodies in EBV-associated neoplastic disorders.

  2. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  3. Validation of a modification to Performance-Tested Method 010403: microwell DNA hybridization assay for detection of Listeria spp. in selected foods and selected environmental surfaces.

    Science.gov (United States)

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false

  4. Systematic review with meta-analysis: diagnostic performance of the combination of pepsinogen, gastrin-17 and anti-Helicobacter pylori antibodies serum assays for the diagnosis of atrophic gastritis.

    Science.gov (United States)

    Zagari, R M; Rabitti, S; Greenwood, D C; Eusebi, L H; Vestito, A; Bazzoli, F

    2017-10-01

    The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays (panel test) is a non-invasive tool for the diagnosis of atrophic gastritis. However, the diagnostic reliability of this test is still uncertain. To assess the diagnostic performance of the serum panel test for the diagnosis of atrophic gastritis. Medline via PubMed, Embase, Scopus, Cochrane Library databases and abstracts of international conferences proceedings were searched from January 1995 to December 2016 using the primary keywords "pepsinogens," "gastrin," "atrophic gastritis," "gastric precancerous lesions." Studies were included if they assessed the accuracy of the serum panel test for the diagnosis of atrophic gastritis using histology according to the updated Sydney System as reference standard. Twenty studies with a total of 4241 subjects assessed the performance of serum panel test for the diagnosis of atrophic gastritis regardless of the site in the stomach. The summary sensitivity was 74.7% (95% confidence interval (CI), 62.0-84.3) and the specificity was 95.6% (95%CI, 92.6-97.4). With a prevalence of atrophic gastritis of 27% (median prevalence across the studies), the negative predictive value was 91%. Few studies with small sample size assessed the performance of the test in detecting the site of atrophic gastritis. The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays appears to be a reliable tool for the diagnosis of atrophic gastritis. This test may be used for screening subjects or populations at high risk of gastric cancer for atrophic gastritis; however, a cost-effectiveness analysis is needed. © 2017 John Wiley & Sons Ltd.

  5. Low sensitivity of type VII collagen enzyme-linked immunosorbent assay in epidermolysis bullosa acquisita : serration pattern analysis on skin biopsy is required for diagnosis

    NARCIS (Netherlands)

    Terra, J. B.; Jonkman, M. F.; Diercks, G. F. H.; Pas, H. H.

    BackgroundThe type VII collagen (coll VII) enzyme-linked immunosorbent assay (ELISA) has been reported to have high sensitivity (>93%) and specificity (>96%) for diagnosing epidermolysis bullosa acquisita (EBA) in patients who are seropositive on indirect immunofluorescence on salt-split skin (SSS).

  6. Determination and validation of a simple high-performance liquid chromatographic method for simultaneous assay of iprodione and vinclozolin in human urine.

    Science.gov (United States)

    Carlucci, Giuseppe; Pasquale, Dorina Di; Ruggieri, Fabrizio; Mazzeo, Pietro

    2005-12-15

    A method based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of 3-(3,5-diclorophenyl)-5-ethenyl-5-methyl-2,4-oxazolidinedione (vinclozolin) and 3-(3,5-diclorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidinecarboxamide (iprodione) in human urine. Urine samples containing vinclozolin and iprodione were collected by solid phase extraction using C(18) cartridges. The chromatographic separation was achieved on a Spherisorb ODS2 (250 mm x 4.6 mm, 5 microm) column with an isocratic mobile phase of acetonitrile-water (60:40, v/v). Detection was UV absorbance at 220 nm. The calibration graphs were linear from 30 to 1000 ng/mL for the two fungicides. Intra- and inter-day R.S.D. did not exceed 2.9%. The quantitation limit was 50 ng/mL for vinclozolin and 30 ng/mL for iprodione, respectively.

  7. Factor IX assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003679.htm Factor IX assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  8. Factor VIII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003678.htm Factor VIII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  9. Factor II assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003674.htm Factor II assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  10. Factor VII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003676.htm Factor VII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  11. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  12. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  13. Nondestructive assay of sale materials

    International Nuclear Information System (INIS)

    Rodenburg, W.W.; Fleissner, J.G.

    1981-01-01

    This paper covers three primary areas: (1) reasons for performing nondestructive assay on SALE materials; (2) techniques used; and (3) discussion of investigators' revised results. The study shows that nondestructive calorimetric assay of plutonium offers a viable alternative to traditional wet chemical techniques. For these samples, the precision ranged from 0.4 to 0.6% with biases less than 0.2%. Thus, for those materials where sampling errors are the predominant source of uncertainty, this technique can provide improved accuracy and precision while saving time and money as well as reducing the amount of liquid wastes to be handled. In addition, high resolution gamma-ray spectroscopy measurements of solids can provide isotopic analysis data in a cost effective and timely manner. The timeliness of the method can be especially useful to the plant operator for production control and quality control measurements

  14. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  15. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  16. Characterisation of L-Type Amino Acid Transporter 1 (LAT1 Expression in Human Skeletal Muscle by Immunofluorescent Microscopy

    Directory of Open Access Journals (Sweden)

    Nathan Hodson

    2017-12-01

    Full Text Available The branch chain amino acid leucine is a potent stimulator of protein synthesis in skeletal muscle. Leucine rapidly enters the cell via the L-Type Amino Acid Transporter 1 (LAT1; however, little is known regarding the localisation and distribution of this transporter in human skeletal muscle. Therefore, we applied immunofluorescence staining approaches to visualise LAT1 in wild type (WT and LAT1 muscle-specific knockout (mKO mice, in addition to basal human skeletal muscle samples. LAT1 positive staining was visually greater in WT muscles compared to mKO muscle. In human skeletal muscle, positive LAT1 staining was noted close to the sarcolemmal membrane (dystrophin positive staining, with a greater staining intensity for LAT1 observed in the sarcoplasmic regions of type II fibres (those not stained positively for myosin heavy-chain 1, Type II—25.07 ± 5.93, Type I—13.71 ± 1.98, p < 0.01, suggesting a greater abundance of this protein in these fibres. Finally, we observed association with LAT1 and endothelial nitric oxide synthase (eNOS, suggesting LAT1 association close to the microvasculature. This is the first study to visualise the distribution and localisation of LAT1 in human skeletal muscle. As such, this approach provides a validated experimental platform to study the role and regulation of LAT1 in human skeletal muscle in response to various physiological and pathophysiological models.

  17. Diagnostic utility of a direct immunofluorescence test to detect feline coronavirus antigen in macrophages in effusive feline infectious peritonitis.

    Science.gov (United States)

    Litster, A L; Pogranichniy, R; Lin, T-L

    2013-11-01

    The antemortem diagnosis of feline infectious peritonitis (FIP) remains challenging in clinical practice, since current testing methods have suboptimal diagnostic accuracy. Immunohistochemical testing of biopsy specimens and postmortem examination are the standard diagnostic methods, although direct immunofluorescence (DIF) testing to detect feline coronavirus in macrophages in effusion specimens has been reported to have 100% specificity and has been recommended as an antemortem confirmatory test. The aim of this study was to compare the results of DIF testing in antemortem feline effusions with postmortem results using field samples. Effusion specimens were collected antemortem from 17 cats and tested by DIF, followed by postmortem examination. Histopathological examination of specimens collected at postmortem confirmed FIP in 10/17 cases and ruled out FIP out in 7/17 cases. Antemortem DIF testing was positive in all 10 cases confirmed as FIP at postmortem examination. In the seven cats where FIP was ruled out at postmortem examination, DIF was negative in five cases and positive in the remaining two cases. The calculated sensitivity of DIF testing was 100% and the specificity was 71.4%. Duplicate effusion specimens from eight cats that were initially DIF positive were stored refrigerated (4 °C) or at room temperature (22-25 °C) and subjected to serial DIF testing to determine the duration of positive results. DIF-positive specimens stored at both temperatures retained their positive status for at least 2 days. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Immunofluorescent histological studies of the role of fibronectin in the expression of the associative preferences of embryonic tissues.

    Science.gov (United States)

    Armstrong, P B; Armstrong, M T

    1981-08-01

    The identity of the chemical factors controlling the spreading behaviour of sheets of cells was examined in organ culture. When aggregates of two dissimilar tissues are apposed in organ culture, one tissue spreads reproducibly over the surface of the second. The present study employed indirect immunofluorescent localization techniques to evaluate the hypothesis that the spreading behaviour of chick embryonic heart tissue in culture is dominated by the presence or absence of the cell-surface and extracellular matrix protein fibronectin in the surface layers of the aggregates. Specifically, the hypothesis proposes that aggregates that display surface fibronectin earlier after culturing and/or in higher quantities segregate internally to aggregates that are slower to develop a surface layer of fibronectin or in which this layer contains reduced amounts of fibronectin. The hypothesis has been supported for 3 categories of behaviour of chick embryo heart tissue: (1) myocyte aggregates spread over myocyte aggregates containing a 20% admixture of heart fibroblasts, which in turn spread over heart fibroblast aggregates; (2) 5-day embryonic ventricle-tissue fragments maintained in culture for 0.5 days spread over ventricle fragments cultured for 2.5 days; and (3) 2-day embryonic ventricle spreads over 5-day ventricle. In all these situations, the aggregate type that segregates to an internal position displays more fibronectin at its surface than aggregate types that spread to occupy an external position. Evidence is presented that the fibronectin in heart tissue aggregates is elaborated by heart fibroblasts.

  19. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  20. Assays for calcitonin receptors

    International Nuclear Information System (INIS)

    Teitelbaum, A.P.; Nissenson, R.A.; Arnaud, C.D.

    1985-01-01

    The assays for calcitonin receptors described focus on their use in the study of the well-established target organs for calcitonin, bone and kidney. The radioligand used in virtually all calcitonin binding studies is 125 I-labelled salmon calcitonin. The lack of methionine residues in this peptide permits the use of chloramine-T for the iodination reaction. Binding assays are described for intact bone, skeletal plasma membranes, renal plasma membranes, and primary kidney cell cultures of rats. Studies on calcitonin metabolism in laboratory animals and regulation of calcitonin receptors are reviewed

  1. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lee, R. Stephen; Ottmar, Herbert; Guardini, Sergio

    1999-01-01

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants [ru

  2. HEMORRHAGIC-FEVER VIRUS-INFECTIONS IN AN ISOLATED RAIN-FOREST AREA OF CENTRAL LIBERIA - LIMITATIONS OF THE INDIRECT IMMUNOFLUORESCENCE SLIDE TEST FOR ANTIBODY SCREENING IN AFRICA

    NARCIS (Netherlands)

    van der Waals, F. W.; Pomeroy, K. L.; Goudsmit, J.; Asher, D. M.; Gajdusek, D. C.

    1986-01-01

    Serum samples from 119 healthy individuals and 106 epilepsy patients inhabiting Grand Bassa County, Liberia, were tested for antibodies to hemorrhagic fever viruses (HFV) by indirect immunofluorescence. E6 Vero cells infected with Lassa fever virus (LAS), Rift Valley Fever virus (RVF), Congo

  3. The detection of Giardia muris and Giardia lamblia cysts by immunofluorescence in animal tissues and fecal samples subjected to cycles of freezing and thawing.

    Science.gov (United States)

    Erlandsen, S L; Sherlock, L A; Bemrick, W J

    1990-04-01

    The effects of freezing and thawing on the detection of selected Giardia spp. cysts were investigated using immunofluorescence, bright field microscopy, and low voltage scanning electron microscopy (SEM). Giardia muris cysts were obtained from either animal carcasses, fecal pellets, or isolated cyst preparations, whereas Giardia lamblia cysts were isolated from fecal samples. These samples were stained using an immunofluorescence technique after 1-3 freezing (-16 C) and thawing (20 C) cycles. Cysts were detected successfully by immunofluorescence in all samples. However, in those samples subjected to freeze-thawing, the cyst walls often became distorted and then were not detectable by bright field microscopy. Low voltage SEM demonstrated that the filaments in the distorted cyst wall underwent rearrangements of interfilament spacing. Quantitation of cyst recovery after freezing and thawing demonstrated that a substantial loss occurred after 1 cycle of alternating temperature when low concentrations of cysts were used, but not with high concentrations of cysts. Cyst recovery, after 3 freezing and thawing cycles, was dramatically lowered irrespective of the initial cyst concentration. These results demonstrated that immunofluorescence was an effective technique for the detection of Giardia spp. cysts in frozen samples and would suggest that freezing and thawing of fecal samples could prevent the detection of cysts when only bright field microscopy was employed.

  4. Longitudinal study of the indirect immunofluorescence and complement fixation tests for diagnosis of chagas' disease in immunosuppressed patients submitted to renal transplantation

    Directory of Open Access Journals (Sweden)

    José Fernando de Castro Figueiredo

    1993-12-01

    Full Text Available Clinical and serological follow-up of 7 patients submitted to renal transplantation and presenting positive serological reactions to Chagas 'disease before immunossupression did not show significant changes in indirect immunofluorescence and complement fixation titres for Chagas ' disease, or signs and symptoms indicating exacerbation of the disease during follow- up. In addition, 18 of 66 recipients of renal transplants considered to be non-chagasic before immunosuppression showed at least one positive result to the indirect immunofluorescence test for Chagas ' disease during the study period. The results suggest that the immunosuppression State induced in chagasic patients submitted to renal transplant did notpromoted exacerbation of the chronic infection in these patients and not interfere with the serological response of chronic chagasics, thus permitting the use of these serologic reactions for diagnostic purposes in these cases. However, the positive results ofthe indirect immunofluorescence test in non- chagasic patients indicate the needforjudicious interpretation ofthe indirect immunofluorescence test for the diagnosis of Chagas' disease in renal transplanted patients.

  5. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  6. Microchemiluminescent assay system

    Energy Technology Data Exchange (ETDEWEB)

    Kiel, J.L.

    1986-04-09

    The patent concerns a microchemiluminescent assay system, which can be used to detect ionizing radiation, heat or specific substances. The method involves the use of a complex formed from serum albumin and a luminescer which, in the presence of ionizing radiation (heat, or a specific analyte), will emit light in an amount proportional to the amount of radiation, etc. (U.K.).

  7. (MTT) dye reduction assay.

    African Journals Online (AJOL)

    to inhibit proliferation of HeLa cells was determined using the 3443- dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) dye reduction assay. Extracts from roots of Agathisanthemum bojeri, Synaptolepis kirkii and Zanha africana and the leaf extract of Physalis peruviana at a concentration of 10 pg/ml inhibited cell ...

  8. Hyaluronic Acid Assays

    DEFF Research Database (Denmark)

    Itenov, Theis S; Kirkby, Nikolai S; Bestle, Morten H

    2015-01-01

    BACKGROUD: Hyaluronic acid (HA) is proposed as a marker of functional liver capacity. The aim of the present study was to compare a new turbidimetric assay for measuring HA with the current standard method. METHODS: HA was measured by a particle-enhanced turbidimetric immunoassay (PETIA) and enzyme...

  9. Optical assay for biotechnology and clinical diagnosis.

    Science.gov (United States)

    Moczko, Ewa; Cauchi, Michael; Turner, Claire; Meglinski, Igor; Piletsky, Sergey

    2011-08-01

    In this paper, we present an optical diagnostic assay consisting of a mixture of environmental-sensitive fluorescent dyes combined with multivariate data analysis for quantitative and qualitative examination of biological and clinical samples. The performance of the assay is based on the analysis of spectrum of the selected fluorescent dyes with the operational principle similar to electronic nose and electronic tongue systems. This approach has been successfully applied for monitoring of growing cell cultures and identification of gastrointestinal diseases in humans.

  10. Calibration method for a radwaste assay system

    International Nuclear Information System (INIS)

    Dulama, C.; Dobrin, R.; Toma, Al.; Paunoiu, C.

    2004-01-01

    A waste assay system entirely designed and manufactured in the Institute for Nuclear Research is used in radwaste treatment and conditioning stream to ensure compliance with national repository radiological requirements. Usually, waste assay systems are calibrated by using various experimental arrangements including calibration phantoms. The paper presents a comparative study concerning the efficiency calibration performed by shell source method and a semiempirical, computational method based on a Monte Carlo algorithm. (authors)

  11. Micro-arrayed human embryonic stem cells-derived cardiomyocytes for in vitro functional assay.

    Directory of Open Access Journals (Sweden)

    Elena Serena

    Full Text Available INTRODUCTION: The heart is one of the least regenerative organs in the body and any major insult can result in a significant loss of heart cells. The development of an in vitro-based cardiac tissue could be of paramount importance for many aspects of the cardiology research. In this context, we developed an in vitro assay based on human cardiomyocytes (hCMs and ad hoc micro-technologies, suitable for several applications: from pharmacological analysis to physio-phatological studies on transplantable hCMs. We focused on the development of an assay able to analyze not only hCMs viability, but also their functionality. METHODS: hCMs were cultured onto a poly-acrylamide hydrogel with tunable tissue-like mechanical properties and organized through micropatterning in a 20×20 array. Arrayed hCMs were characterized by immunofluorescence, GAP-FRAP analyses and live and dead assay. Their functionality was evaluated monitoring the excitation-contraction coupling. RESULTS: Micropatterned hCMs maintained the expression of the major cardiac markers (cTnT, cTnI, Cx43, Nkx2.5, α-actinin and functional properties. The spontaneous contraction frequency was (0.83±0.2 Hz, while exogenous electrical stimulation lead to an increase up to 2 Hz. As proof of concept that our device can be used for screening the effects of pathological conditions, hCMs were exposed to increasing levels of H(2O(2. Remarkably, hCMs viability was not compromised with exposure to 0.1 mM H(2O(2, but hCMs contractility was dramatically suppressed. As proof of concept, we also developed a microfluidic platform to selectively treat areas of the cell array, in the perspective of performing multi-parametric assay. CONCLUSIONS: Such system could be a useful tool for testing the effects of multiple conditions on an in vitro cell model representative of human heart physiology, thus potentially helping the processes of therapy and drug development.

  12. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  13. Green Approach To Synthesize Crystalline Nanoscale ZnII-Coordination Polymers: Cell Growth Inhibition and Immunofluorescence Study.

    Science.gov (United States)

    Mukherjee, Somali; Ganguly, Sumi; Manna, Krishnendu; Mondal, Sanchaita; Mahapatra, Supratim; Das, Debasis

    2018-04-02

    Five new coordination polymers (CPs) namely, [{Zn(μ 2 -H 2 O) 0.5 (5N 3 -IPA)(2,2'-bpe)}] ∞ (1), [{Zn(μ 2 -H 2 O) 0.5 (5N 3 -IPA)(1,10-phen)}] ∞ (2), [{Zn(5N 3 -IPA)(1,2-bpe)}] ∞ (3), [{Zn(5N 3 -IPA)(1,2-bpey)}] ∞ (4), and [{Zn(H 2 O)(5N 3 -IPA)(4,4'-tme)}(H 2 O) 0.5 ] ∞ (5) (5N 3 -H 2 IPA = 5-azidoisophthalic acid, 2,2'-bpe= 2,2'-bipyridine, 1,10-phen = 1,10-phenanthroline, 1,2-bpe = 1,2-bis(4-pyridyl)ethane, 1,2-bpey = 1,2-bis(4-pyridyl)ethylene, 4,4'-tme = 4,4'-trimethylenedipyridine), have been synthesized based on a mixed ligand approach adopting a solvothermal technique. Depending upon the intrinsic structural flexibility of the bis-pyridyl coligands, interesting structural topologies have also been observed in the resulting CPs: Sra SrAl2 type topology for 3 and a 3-fold interpenetrated dmp topology for 4. A green hand grinding technique has been implemented to reduce the particle size of the CPs to generate nanoscale CPs (NCPs). SEM studies of NCPs reveal the formation of square and spherical particles for NCP 1 and 2, respectively, and nano rod for NCP 3, 4, and 5. Remarkably, when scaled down to nano range all the NCPs retain their crystalline nature. The cytotoxic activity of the NCPs (1-5) has been studied using human colorectal carcinoma cells (HCT 116). Significant cell death is observed for NCP 2, which is further corroborated by cell growth inhibition study. The observed cell death is likely to be due to mitochondrial-assisted apoptosis as is evident from immunofluorescence study.

  14. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  15. Radioreceptor assay for oxyphenonium

    International Nuclear Information System (INIS)

    Ensing, K.; Zeeuw, R.A. de

    1984-01-01

    The development of a radioreceptor assay for the quaternary anticholinergic drug, oxyphenonium, in plasma is reported. It is based on competition between this drug and 3 H-dexetimide for binding to muscarinic receptors. After ion pair extraction and reextraction, the drug can be determined in plasma at concentrations down to a value of 100 pg/ml. This permits pharmacokinetic studies to be made after inhalation of oxyphenonium. (author)

  16. Development and validation of a simple high performance thin layer chromatography method combined with direct 1,1-diphenyl-2-picrylhydrazyl assay to quantify free radical scavenging activity in wine.

    Science.gov (United States)

    Agatonovic-Kustrin, Snezana; Morton, David W; Yusof, Ahmad P

    2016-04-15

    The aim of this study was to: (a) develop a simple, high performance thin layer chromatographic (HPTLC) method combined with direct 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay to rapidly assess and compare free radical scavenging activity or anti-oxidant activity for major classes of polyphenolics present in wines; and (b) to investigate relationship between free radical scavenging activity to the total polyphenolic content (TPC) and total antioxidant capacity (TAC) in the wine samples. The most potent free radical scavengers that we tested for in the wine samples were found to be resveratrol (polyphenolic non-flavonoid) and rutin (flavonoid), while polyphenolic acids (caffeic acid and gallic acid) although present in all wine samples were found to be less potent free radical scavengers. Therefore, the total antioxidant capacity was mostly affected by the presence of resveratrol and rutin, while total polyphenolic content was mostly influenced by the presence of the less potent free radical scavengers gallic and caffeic acids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A comparative study of an elisa test and an indirect immunofluorescence test for serological diagnosis of Babesia bovis infection

    International Nuclear Information System (INIS)

    Martins, J.R.; Cheong, F.H.; Correa, B.L.; Radley, D.E.; Cereser, V.H.

    1998-01-01

    Detection of antibodies to Babesia bovis in cattle is essential for the understanding of the epidemiology of babesiosis and this study was concerned with comparing the indirect fluorescent antibody with the ELISA. Both assays gave rise to 100% sensitivity whilst the ELISA was shown to be marginally more specific at 98%. The ease of use and low cost of the ELISA would make it the more obvious choice in conducting future serological surveys for this parasite. (author)

  18. [Application of Immunohistochemistry and Immunofluorescence Staining in Detection of Phospholipase A2 Receptor on Paraffin Section of Renal Biopsy Tissue].

    Science.gov (United States)

    Dong, Hong-rui; Wang, Yan-yan; Wang, Guo-qin; Sun, Li-jun; Cheng, Hong; Chen, Yi-pu

    2015-10-01

    immunohistochemical staining and immunofluorescence staining, the preferred method of antigen repair is water bath heat repair plus trypsin repair.

  19. Radiorespirometic assay device

    International Nuclear Information System (INIS)

    Levin, G.V.; Straat, P.A.

    1981-01-01

    A radiorespirometic assay device is described in which the presence of microorganisms in a sample is determined by placing the sample in contact with a metabolisable radioactive labelled substrate, collecting any gas evolved, exposing a photosensitive material to the gas and determining if a spot is produced on the material. A spot indicates the presence of radioactivity showing that the substrate has been metabolized by a microorganism. Bacteria may be detected in body fluids, hospital operating rooms, water, food, cosmetics and drugs. (U.K.)

  20. Radon assay for SNO+

    Energy Technology Data Exchange (ETDEWEB)

    Rumleskie, Janet [Laurentian University, Greater Sudbury, Ontario (Canada)

    2015-12-31

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+.

  1. Subclass of individual IgA-secreting human lymphocytes. Investigation of in vivo pneumococcal polysaccharide-induced and in vitro mitogen-induced blood B cells by monolayer plaque-forming cell assays

    DEFF Research Database (Denmark)

    Heilmann, C; Barington, T; Sigsgaard, T

    1988-01-01

    The subclass of individual human IgA B cells was investigated by means of monolayer plaque-forming cell assays permitting analysis of all IgA-secreting cells as well as of cells secreting IgA anti-pneumococcal polysaccharide antibody. Center cells were examined by indirect immunofluorescence...

  2. RAS - Screens & Assays - Drug Discovery

    Science.gov (United States)

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  3. Rotor assembly and assay method

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1993-09-07

    A rotor assembly for carrying out an assay includes a rotor body which is rotatable about an axis of rotation, and has a central chamber and first, second, third, fourth, fifth, and sixth chambers which are in communication with and radiate from the central chamber. The rotor assembly further includes a shuttle which is movable through the central chamber and insertable into any of the chambers, the shuttle including a reaction cup carrying an immobilized antigen or an antibody for transport among the chambers. A method for carrying out an assay using the rotor assembly includes moving the reaction cup among the six chambers by passing the cup through the central chamber between centrifugation steps in order to perform the steps of: separating plasma from blood cells, binding plasma antibody or antigen, washing, drying, binding enzyme conjugate, reacting with enzyme substrate and optically comparing the resulting reaction product with unreacted enzyme substrate solution. The movement of the reaction cup can be provided by attaching a magnet to the reaction cup and supplying a moving magnetic field to the rotor. 34 figures.

  4. Improving shuffler assay accuracy

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-01-01

    Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year

  5. Competitive protein binding assay

    International Nuclear Information System (INIS)

    Kaneko, Toshio; Oka, Hiroshi

    1975-01-01

    The measurement of cyclic GMP (cGMP) by competitive protein binding assay was described and discussed. The principle of binding assay was represented briefly. Procedures of our method by binding protein consisted of preparation of cGMP binding protein, selection of 3 H-cyclic GMP on market, and measurement procedures. In our method, binding protein was isolated from the chrysalis of silk worm. This method was discussed from the points of incubation medium, specificity of binding protein, the separation of bound cGMP from free cGMP, and treatment of tissue from which cGMP was extracted. cGMP existing in the tissue was only one tenth or one scores of cGMP, and in addition, cGMP competed with cGMP in binding with binding protein. Therefore, Murad's technique was applied to the isolation of cGMP. This method provided the measurement with sufficient accuracy; the contamination by cAMP was within several per cent. (Kanao, N.)

  6. High-recovery visual identification and single-cell retrieval of circulating tumor cells for genomic analysis using a dual-technology platform integrated with automated immunofluorescence staining

    International Nuclear Information System (INIS)

    Campton, Daniel E; Ramirez, Arturo B; Nordberg, Joshua J; Drovetto, Nick; Clein, Alisa C; Varshavskaya, Paulina; Friemel, Barry H; Quarre, Steve; Breman, Amy; Dorschner, Michael; Blau, Sibel; Blau, C Anthony; Sabath, Daniel E; Stilwell, Jackie L; Kaldjian, Eric P

    2015-01-01

    Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte® – CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte – CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte

  7. Appraisal of within- and between-laboratory reproducibility of non-radioisotopic local lymph node assay using flow cytometry, LLNA:BrdU-FCM: comparison of OECD TG429 performance standard and statistical evaluation.

    Science.gov (United States)

    Yang, Hyeri; Na, Jihye; Jang, Won-Hee; Jung, Mi-Sook; Jeon, Jun-Young; Heo, Yong; Yeo, Kyung-Wook; Jo, Ji-Hoon; Lim, Kyung-Min; Bae, SeungJin

    2015-05-05

    Mouse local lymph node assay (LLNA, OECD TG429) is an alternative test replacing conventional guinea pig tests (OECD TG406) for the skin sensitization test but the use of a radioisotopic agent, (3)H-thymidine, deters its active dissemination. New non-radioisotopic LLNA, LLNA:BrdU-FCM employs a non-radioisotopic analog, 5-bromo-2'-deoxyuridine (BrdU) and flow cytometry. For an analogous method, OECD TG429 performance standard (PS) advises that two reference compounds be tested repeatedly and ECt(threshold) values obtained must fall within acceptable ranges to prove within- and between-laboratory reproducibility. However, this criteria is somewhat arbitrary and sample size of ECt is less than 5, raising concerns about insufficient reliability. Here, we explored various statistical methods to evaluate the reproducibility of LLNA:BrdU-FCM with stimulation index (SI), the raw data for ECt calculation, produced from 3 laboratories. Descriptive statistics along with graphical representation of SI was presented. For inferential statistics, parametric and non-parametric methods were applied to test the reproducibility of SI of a concurrent positive control and the robustness of results were investigated. Descriptive statistics and graphical representation of SI alone could illustrate the within- and between-laboratory reproducibility. Inferential statistics employing parametric and nonparametric methods drew similar conclusion. While all labs passed within- and between-laboratory reproducibility criteria given by OECD TG429 PS based on ECt values, statistical evaluation based on SI values showed that only two labs succeeded in achieving within-laboratory reproducibility. For those two labs that satisfied the within-lab reproducibility, between-laboratory reproducibility could be also attained based on inferential as well as descriptive statistics. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. The narrow therapeutic window of glycated hemoglobin and assay variability.

    Science.gov (United States)

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  9. Controlling variation in the comet assay

    Directory of Open Access Journals (Sweden)

    Andrew Richard Collins

    2014-10-01

    Full Text Available Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardising the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of alkaline incubation, and electrophoresis conditions (time, temperature and voltage gradient are particularly important. Even when these are controlled, variation seems to be inevitable. It is helpful to include in experiments reference standards, i.e. cells with a known amount of specific damage to the DNA. They can be aliquots frozen from a single large batch of cells, either untreated (negative controls or treated with, for example, H2O2 or X-rays to induce strand breaks (positive control for the basic assay, or photosensitiser plus light to oxidise guanine (positive control for Fpg- or OGG1-sensitive sites. Reference standards are especially valuable when performing a series of experiments over a long period - for example, analysing samples of white blood cells from a large human biomonitoring trial - to check that the assay is performing consistently, and to identify anomalous results necessitating a repeat experiment. The reference values of tail intensity can also be used to iron out small variations occurring from day to day. We present examples of the use of reference standards in human trials, both within one laboratory and between different laboratories, and describe procedures that can be used to control variation.

  10. An acoustic prion assay

    Directory of Open Access Journals (Sweden)

    Gordon Hayward

    2016-12-01

    Full Text Available An acoustic prion assay has been demonstrated for sheep brain samples. Only five false positives and no false negatives were observed in a test of 45 positive and 45 negative samples. The acoustic prion sensor was constructed using a thickness shear mode quartz resonator coated with a covalently bound recombinant prion protein. The characteristic indicator of a scrapie infected sheep brain sample was an observed shoulder in the frequency decrease in response to a sample.The response of the sensor aligns with a conformational shift in the surface protein and with the propagation mechanism of the disease. This alignment is evident in the response timing and shape, dependence on concentration, cross species behaviour and impact of blood plasma. This alignment is far from sufficient to prove the mechanism of the sensor but it does offer the possibility of a rapid and inexpensive additional tool to explore prion disease. Keywords: Prions, Thickness shear mode quartz sensor

  11. Assay of oestrogen

    International Nuclear Information System (INIS)

    Edwards, J.C.

    1981-01-01

    A particular problem with the direct radioimmunoassay of unconjugated oestriol in pregnancy is caused by the increased amount of steroid-binding proteins present in pregnancy serum and plasma. The steroid-binding proteins react with oestriol and 125 I-labelled oestriol during the assay procedure and the steroid-protein bound 125 I-labelled oestriol is precipitated along with the antibody-bound 125 I-labelled oestriol by the ammonium sulphate solution separation system. A novel method is described whereby progesterone (1-20 μg/ml) is used to block the action of steroid-binding proteins in pregnancy serum and plasma samples, thus minimizing interference in a direct radioimmunoassay for unconjugated oestriol using a specific anti-oestriol serum. (U.K.)

  12. Analysis of monoamine oxidase (MAO) enzymatic activity by high-performance liquid chromatography-diode array detection combined with an assay of oxidation with a peroxidase and its application to MAO inhibitors from foods and plants.

    Science.gov (United States)

    Herraiz, Tomás; Flores, Andrea; Fernández, Lidia

    2018-01-15

    Monoamine oxidase (MAO) enzymes catalyze the oxidative deamination of biogenic amines and neurotransmitters and produce ammonia, aldehydes, and hydrogen peroxide which is involved in oxidative processes. Inhibitors of MAO-A and -B isozymes are useful as antidepressants and neuroprotectants. The assays of MAO usually measure amine oxidation products or hydrogen peroxide by spectrophotometric techniques. Those assays are often compromised by interfering compounds resulting in poor results. This research describes a new method that combines in the same assay the oxidative deamination of kynuramine to 4-hydroxyquinoline analyzed by HPLC-DAD with the oxidation of tetramethylbenzidine (TMB) (or Amplex Rex) by horseradish peroxidase (HRP) in presence of hydrogen peroxide. The new method was applied to study the inhibition of human MAO-A and -B by bioactive compounds including β-carboline alkaloids and flavonoids occurring in foods and plants. As determined by HPLC-DAD, β-carbolines, methylene blue, kaempferol and clorgyline inhibited MAO-A and methylene blue, 5-nitroindazole, norharman and deprenyl inhibited MAO-B, and all of them inhibited the oxidation of TMB in the same extent. The flavonoids catechin and cyanidin were not inhibitors of MAO by HPLC-DAD but highly inhibited the oxidation of TMB (or Amplex Red) by peroxidase whereas quercetin and resveratrol were moderate inhibitors of MAO-A by HPLC-DAD, but inhibited the peroxidase assay in a higher level. For some phenolic compounds, using the peroxidase-coupled assay to measure MAO activity led to mistaken results. The new method permits to discern between true inhibitors of MAO from those that are antioxidants and which interfere with peroxidase assays but do not inhibit MAO. For true inhibitors of MAO, inhibition as determined by HPLC-DAD correlated well with inhibition of the oxidation of TMB and this approach can be used to assess the in vitro antioxidant activity (less hydrogen peroxide production) resulting

  13. Comparison of five assays for detection of Clostridium difficile toxin.

    Science.gov (United States)

    Chapin, Kimberle C; Dickenson, Roberta A; Wu, Fongman; Andrea, Sarah B

    2011-07-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  14. Comparison of Five Assays for Detection of Clostridium difficile Toxin

    Science.gov (United States)

    Chapin, Kimberle C.; Dickenson, Roberta A.; Wu, Fongman; Andrea, Sarah B.

    2011-01-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. PMID:21704273

  15. A Qualitative Study Comparing the Assay Performance Characteristics Between the 2007 and the 2013 American Society for Clinical Oncology and College of American Pathologists HER2 Scoring Methods in Mucinous Epithelial Ovarian Cancer

    Science.gov (United States)

    Chen, Chi-Kuan; Lee, Ming-Yung; Lin, Wea-Lung; Wang, Yu-Ting; Han, Chih-Ping; Yu, Cheng-Ping; Chao, Wan-Ru

    2014-01-01

    Abstract The remarkable success of trastuzumab and other newly developed anti-HER2 (human epidermal growth factor receptor 2) therapies in breast, gastric, or gastroesophageal junction cancer patients has supported us to investigate the HER2 status and its possible therapeutic implication in mucinous epithelial ovarian cancer (EOC). However, there is currently no standardization of HER2 scoring criteria in mucinous EOC. In this study, we aimed to compare both the assay performance characteristics of the 2007 and the 2013 American Society for Clinical Oncology and College of American Pathologists scoring methods. Forty-nine tissue microarray samples of mucinous EOC from Asian women were analyzed by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) tests using the 2007 and the 2013 criteria, respectively. The overall concordance between IHC and FISH by the 2007 criteria was 97.92 % (kappa = 0.921), and that by the 2013 criteria was 100% (kappa = 1.000). The percentage of Her2 FISH-amplified cases showed an increasing trend significantly through their corresponding HER2 IHC ordinals by the 2007 and the 2013 criteria, respectively (P < 0.001, P < 0.001). After excluding equivocal cases, the specificity (100%) and positive predictive value (100%) were unchanged under either the 2007 or the 2013 criteria. The sensitivity (100%), negative predictive value (NPV) (100%), and accuracy (100%) of HER2 IHC were higher under the 2013 criteria than those (sensitivity 87.5%, NPV 97.6%, and accuracy 97.9%) under the 2007 criteria. Of the total 49 cases, the number (n = 4) of HER2 IHC equivocal results under the 2013 criteria was 4-fold higher than that (n = 1) under the 2007 criteria (8.16% vs 2.04%). Conclusively, if first tested by IHC, the 2013 criteria caused more equivocal HER2 IHC cases to be referred to Her2 FISH testing than the 2007 criteria. That decreased the false-negative rate of HER2 status and increased the detection

  16. High-performance liquid chromatography-fluorescence assay of pyruvic acid to determine cysteine conjugate beta-lyase activity : application to S-1,2-dichlorovinyl-L-cysteine and S-2-benzothiazolyl-L-cysteine

    NARCIS (Netherlands)

    Stijntjes, G.J.; te Koppele, J.M.; Vermeulen, N P

    1992-01-01

    An HPLC-fluorescence assay has been developed for the determination of the activity of rat renal cytosolic cysteine conjugate beta-lyase. The method is based on isocratic HPLC separation and fluorescence detection of pyruvic acid, derivatized with o-phenylenediamine (OPD), and is shown to be rapid,

  17. Development and optimization of a direct plaque assay for human and avian metapneumoviruses

    Science.gov (United States)

    Zhang, Yu; Wei, Yongwei; Li, Junan; Li, Jianrong

    2012-01-01

    The genus Metapneumovirus within the subfamily Pneumovirinae and family Paramyxoviridae includes only two viruses, human metapneumovirus (hMPV) and avian metapneumovirus (aMPV), which cause respiratory disease in humans and birds, respectively. These two viruses grow poorly in cell culture and other quantitation methods, such as indirect immuno-staining and immuno-fluorescent assays, are expensive, time consuming, and do not allow for plaque purification of the virus. In order to enhance research efforts for studying these two viruses, a direct plaque assay for both hMPV and aMPV has been developed. By optimizing the chemical components of the agarose overlay, it was found that both hMPV with a trypsin-independent F cleavage site and aMPV formed clear and countable plaques in a number of mammalian cell lines (such as Vero-E6 and LLC-MK2 cells) after 5 days of incubation. The plaque forming assay has similar sensitivity and reliability as the currently used immunological methods for viral quantitation. The plaque assay is also a more simple, rapid, and economical method compared to immunological assays, and in addition allows for plaque purification of the viruses. The direct plaque assay will be a valuable method for the quantitation and evaluation of the biological properties of some metapneumoviruses. PMID:22684013

  18. Evaluation of a molybdenum assay canister

    International Nuclear Information System (INIS)

    Yoshizumi, T.T.; Keener, S.J.

    1988-01-01

    The performance characteristics of a commercial molybdenum assay canister were evaluated. The geometrical variation of the technetium-99m (/sup 99m/Tc) activity reading was studied as a function of the elution volume for the standard vials. It was found that the /sup 99m/Tc canister activity reading was ∼ 5% lower than that of the standard method. This is due to attenuation by the canister wall. However, the effect of the geometric variation on the clinical dose preparation was found to be insignificant. The molybdenum-99 ( 99 Mo) contamination level was compared by two methods: (1) the commercial canister and (2) the standard assay kit. The 99 Mo contamination measurements with the canister indicated consistently lower readings than those with the standard 99 Mo assay kit. The authors conclude that the canister may be used in the clinical settings. However, the user must be aware of the problems and the limitations associated with this canister

  19. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  20. Cell-based quantification of biomarkers from an ultra-fast microfluidic immunofluorescent staining: application to human breast cancer cell lines

    Science.gov (United States)

    Migliozzi, D.; Nguyen, H. T.; Gijs, M. A. M.

    2018-02-01

    Immunohistochemistry (IHC) is one of the main techniques currently used in the clinics for biomarker characterization. It consists in colorimetric labeling with specific antibodies followed by microscopy analysis. The results are then used for diagnosis and therapeutic targeting. Well-known drawbacks of such protocols are their limited accuracy and precision, which prevent the clinicians from having quantitative and robust IHC results. With our work, we combined rapid microfluidic immunofluorescent staining with efficient image-based cell segmentation and signal quantification to increase the robustness of both experimental and analytical protocols. The experimental protocol is very simple and based on fast-fluidic-exchange in a microfluidic chamber created on top of the formalin-fixed-paraffin-embedded (FFPE) slide by clamping it a silicon chip with a polydimethyl siloxane (PDMS) sealing ring. The image-processing protocol is based on enhancement and subsequent thresholding of the local contrast of the obtained fluorescence image. As a case study, given that the human epidermal growth factor receptor 2 (HER2) protein is often used as a biomarker for breast cancer, we applied our method to HER2+ and HER2- cell lines. We report very fast (5 minutes) immunofluorescence staining of both HER2 and cytokeratin (a marker used to define the tumor region) on FFPE slides. The image-processing program can segment cells correctly and give a cell-based quantitative immunofluorescent signal. With this method, we found a reproducible well-defined separation for the HER2-to-cytokeratin ratio for positive and negative control samples.

  1. Discordant results obtained on testing sera from immunocompromised patients for cytomegalovirus IgG by enzyme-linked immunosorbent assay and radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; El Mohandes, L; Tryhorn, Y S [London University (United Kingdom). St. George' s Hospital Medical School, Department of Medical Microbiology; Kangro, H O; Liu, K M [Saint Bartholomew' s Hospital, London (UK)

    1989-10-01

    The investigation of sera from immunocompromised patients for antibody to CMV by ELISA, RIA, immunofluorescence (IF) and complement-fixation (CF) revealed discrepancies that reflected differences in test specificity rather than sensitivity and suggested that for the long-term serological follow-up of such patients it would be advisable not to rely on only a single assay procedure. (author). 12 refs.; 8 figs.; 1 tab.

  2. Automated amperometric plutonium assay system

    International Nuclear Information System (INIS)

    Burt, M.C.

    1985-01-01

    The amperometric titration for plutonium assay has been used in the nuclear industry for over twenty years and has been in routine use at the Hanford Engineering Development Laboratory since 1976 for the analysis of plutonium oxide and mixed oxide fuel material for the Fast Flux Test Facility. It has proven itself to be an accurate and reliable method. The method may be used as a direct end point titration or an excess of titrant may be added and a back titration performed to aid in determination of the end point. Due to the slowness of the PuVI-FeII reaction it is difficult to recognize when the end point is being approached and is very time consuming if the current is allowed to decay to the residual value after each titrant addition. For this reason the back titration in which the rapid FeII-CrVI reaction occurs is used by most laboratories. The back titration is performed by the addition of excess ferrous solution followed by two measured aliquots of standard dichromate with measurement of cell current after each addition

  3. Immunofluorescence Microscopy and mRNA Analysis of Human Embryonic Stem Cells (hESCs) Including Primary Cilia Associated Signaling Pathways

    DEFF Research Database (Denmark)

    Vestergaard, Maj Linea; Awan, Aashir; Warzecha, Caroline Becker

    2016-01-01

    onto 16-well glass chambers, and continuing with the general IFM and qPCR anlysis. The techniques are illustrated with results on cellular localization of transcriptional factors and components of the Hedgehog, Wnt, PDGF, and TGFβ signaling pathways to primary cilia in stem cell maintenance......This chapter describes the procedures for immunofluorescence microscopy (IFM) and quantitative PCR (qPCR) analyses of human embryonic stem cells (hESCs) grown specifically under feeder-free conditions. A detailed protocol is provided outlining the steps from initially growing the cells, passaging...

  4. Dew drops on spider web appearance: a newly named pattern of IgG4 deposition in pemphigus with direct immunofluorescence

    Directory of Open Access Journals (Sweden)

    Marian Dmochowski

    2017-08-01

    Full Text Available Novel appearances in cutaneous pathology as well as mucocutaneous clinical signs are being described which indicate that this is still an attractive area for exploration. The H + E histology terms of “decorated tomb stoning” and “undecorated tomb stoning”, advocated by some pathologists, are misleading and as such should be avoided. Here, an appearance of IgG4 pemphigus deposits examined cost-effectively with direct immunofluorescence and suggested to be called “dew drops on spider web” is depicted in depth.

  5. Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.

    Science.gov (United States)

    Bentsen, Christopher; McLaughlin, Lisa; Mitchell, Elizabeth; Ferrera, Carol; Liska, Sally; Myers, Robert; Peel, Sheila; Swenson, Paul; Gadelle, Stephane; Shriver, M Kathleen

    2011-12-01

    A multi-center study was conducted to evaluate the Bio-Rad GS HIV Combo Ag/Ab EIA, a 4th generation HIV-1/HIV-2 assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma in adult and pediatric populations. The objectives of the study were to assess assay performance for the detection of acute HIV infections; sensitivity in known HIV positive samples; percent agreement with HIV status; specificity in low and high risk individuals of unknown HIV status; and to compare assay performance to a 3rd generation HIV assay. The evaluation included testing 9150 samples at four U.S. clinical trial sites, using three kit lots. Unlinked samples were from routine testing, repositories or purchased from vendors. GS HIV Combo Ag/Ab EIA detection in samples from individuals in two separate populations with acute HIV infection was 95.2% (20/21) and 86.4% (38/44). Sensitivity was 100% (1603/1603) in known antibody positive [HIV-1 Groups M and O, and HIV-2] samples. HIV p24 antigen detection was 100% (53/53) in HIV-1 culture supernatants. HIV-1 seroconversion panel detection improved by a range of 0-20 days compared to a 3rd generation HIV test. Specificity was 99.9% (5989/5996) in low risk, 99.9% (959/960) in high risk and 100% (100/100) in pediatric populations. The GS HIV Combo Ag/Ab EIA significantly reduced the diagnostic window when compared to the 3rd generation screening assay, enabling earlier diagnosis of HIV infection. The performance parameters of the Bio-Rad GS HIV Combo Ag/Ab EIA are well suited for use in HIV diagnostic settings. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Timothy M. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Lambert, Iain B. [Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Williams, Andrew [Biostatistics and Epidemiology Division, Safe Environments Programme, 6604B, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Douglas, George R. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Yauk, Carole L. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada)]. E-mail: carole_yauk@hc-sc.gc.ca

    2006-06-25

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.

  7. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    International Nuclear Information System (INIS)

    Singer, Timothy M.; Lambert, Iain B.; Williams, Andrew; Douglas, George R.; Yauk, Carole L.

    2006-01-01

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development

  8. FLIPR assays of intracellular calcium in GPCR drug discovery

    DEFF Research Database (Denmark)

    Hansen, Kasper Bø; Bräuner-Osborne, Hans

    2009-01-01

    Fluorescent dyes sensitive to changes in intracellular calcium have become increasingly popular in G protein-coupled receptor (GPCR) drug discovery for several reasons. First of all, the assays using the dyes are easy to perform and are of low cost compared to other assays. Second, most non...

  9. Reagents for the assay of cardenolide glycosides and aglycones

    International Nuclear Information System (INIS)

    Wilkinson, S.

    1976-01-01

    Some novel reagents are described for use in the radioimmunoassay of the 3-glycone derivatives of cardenolides (cardiac glycosides) and more especially digoxin, digitoxin, gitoxin, periplocin and lanatosides. Using these reagents these cardenolides and their derivatives may be assayed both in aqueous solution and in urine. A method is also described for performing such assays, including a suitable kit. (U.K.)