WorldWideScience

Sample records for immunoassay life detection

  1. Detection of narcotics with an immunoassay film badge

    International Nuclear Information System (INIS)

    Lukens, H.R.

    1993-01-01

    Efficient personnel performance, a major requirement for a safe nuclear industry, is jeopardized where personnel use narcotics. However, detection of narcotics at nuclear plants is a challenge. The unique specificity and sensitivity of an immunoassay has been implemented in the form of a small, dry immunoassay film badge (IFB) for the detection of vapors emitted by narcotics. The device is suitable as an area monitor, and its characteristics are suitable for use as a breath monitor for the detection of drug use

  2. Nanobody medicated immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein.

    Science.gov (United States)

    Chen, Jing; He, Qing-hua; Xu, Yang; Fu, Jin-heng; Li, Yan-ping; Tu, Zhui; Wang, Dan; Shu, Mei; Qiu, Yu-lou; Yang, Hong-wei; Liu, Yuan-yuan

    2016-01-15

    Immunoassay for cancer biomarkers plays an important role in cancer prevention and early diagnosis. To the development of immunoassay, the quality and stability of applied antibody is one of the key points to obtain reliability and high sensitivity for immunoassay. The main purpose of this study was to develop a novel immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein (AFP) based on nanobody against AFP. Two nanobodies which bind to AFP were selected from a phage display nanobody library by biopanning strategy. The prepared nanobodies are clonable, thermally stable and applied in both sandwich enzyme linked immunoassay (ELISA) and immuno-PCR assay for ultrasensitive detection of AFP. The limit detection of sandwich ELISA setup with optimized nanobodies was 0.48ng mL(-1), and the half of saturation concentration (SC50) value was 6.68±0.56ng mL(-1). These nanobodies were also used to develop an immuno-PCR assay for ultrasensitive detection of AFP, its limit detection values was 0.005ng mL(-1), and the linear range was 0.01-10,000ng mL(-1). These established immunoassays based on nanobodies were highly specific to AFP and with negligible cross reactivity with other tested caner biomarkers. Furthermore, this novel concept of nanobodies mediated immunoassay may provide potential applications in a general method for the ultrasensitive detection of various cancer biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Fluorescence immunoassay for detecting periodontal bacterial pathogens in plaque.

    OpenAIRE

    Wolff, L F; Anderson, L; Sandberg, G P; Aeppli, D M; Shelburne, C E

    1991-01-01

    A particle concentration fluorescence immunoassay has been modified into a bacterial concentration fluorescence immunoassay (BCFIA) to rapidly detect periodontopathic bacteria in human plaque samples. The BCFIA utilizes fluorescently tagged monoclonal antibodies (MAbs) directed against the lipopolysaccharide of selected gram-negative plaque bacteria. Microorganisms closely associated with periodontal disease that can be identified in plaque with the BCFIA include Porphyromonas gingivalis, Bac...

  4. Development of immunoassays for detecting clothianidin residue in agricultural products.

    Science.gov (United States)

    Li, Ming; Sheng, Enze; Cong, Lujing; Wang, Minghua

    2013-04-17

    Two enzyme-linked immunosorbent assays (ELISAs) based on polyclonal antibodies (PcAbs) for clothianidin are described: colorimetric detection format (ELISA) and pattern of chemiluminescent assay (CLEIA). Clothianidin hapten was synthesized and conjugated to bovine serum albumin (BSA) and ovalbumin (OVA) to produce immunogen and coating antigen. Anticlothianidin PcAbs were obtained from immunized New Zealand white rabbits. Under optimal conditions, the half-maximal inhibition concentration (IC₅₀) and the limit of detection (LOD, IC₂₀) of clothianidin were 0.046 and 0.0028 mg/L for the ELISA and 0.015 and 0.0014 mg/L for the CLEIA, respectively. There were no obvious cross-reactivities of the antibodies with its analogues except for dinotefuran. Recoveries of 76.4-116.4% for the immunoassays were achieved from spiked samples. The results of immunoassays for the spiked and authentic samples were largely consistent with gas chromatography. Therefore, the proposed immunoassays would be convenient and satisfactory analytical methods for the monitoring of clothianidin in agricultural products.

  5. Which amphetamine-type stimulants can be detected by oral fluid immunoassays?

    Science.gov (United States)

    Souza, Daniele Z; Boehl, Paula O; Comiran, Eloisa; Prusch, Débora S; Zancanaro, Ivomar; Fuentefria, Alexandre M; Pechansky, Flavio; Duarte, Paulina C A V; De Boni, Raquel B; Fröehlich, Pedro E; Limberger, Renata P

    2012-02-01

    The use of oral fluid for monitoring drug consumption on roads has many advantages over conventional biological fluids; therefore, several immunoassays have been developed for this purpose. In this work, the ability of 3 commercial immunoassays to detect amphetamine-type stimulants (ATSs) in oral fluid was assessed. In addition, it was reviewed the main controlled ATSs available worldwide, as well as the oral fluid immunological screening tests that have been used for identifying ATSs in drivers. The analytical specificity of amphetamine direct enzyme-linked immunosorbent assay (ELISA), methamphetamine direct ELISA (Immunalysis Corporation), and Oral-View saliva multidrug of abuse test (Alfa Scientific Designs) was evaluated using ATS-spiked oral fluid. Legislation and published articles that report the use of immunological screening tests to detect ATS consumption in conductors were reviewed, including the kit's technical information, project reports, police and drug databases. Even at high concentrations, the tested assays were not able to detect methylphenidate, fenproporex, or diethylpropion, controlled ATSs legally marketed in many countries. This evidences the need to develop new kits that enable one to control the misuse of prescription ATSs on roads through oral fluid immunoassays.

  6. IMMUNOASSAYS FOR THE DETECTION OF UROKINASE RECEPTOR FORMS

    DEFF Research Database (Denmark)

    2004-01-01

    amounts of uPAR forms in a sample with data indicative of the presence of the cancer disease. The method can be used for staging, prognosis or diagnosis of prostate cancer. Two novel monoclonal antibodies and a kit and immunoassays for detecting at least one uPAR form(s) are also described in the present...

  7. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  8. Rapid detection of fungal alpha-amylase in the work environment with a lateral flow immunoassay

    NARCIS (Netherlands)

    Bogdanovic, J.; Koets, M.; Sander, I.; Wouters, I.; Meijster, T.; Heederik, D.J.J.; Amerongen, van A.; Doekes, G.

    2006-01-01

    Background Occupational allergen exposure assessment usually requires airborne dust sampling at the worksite followed by dust extraction and enzyme immunoassay (EIA) analysis at the laboratory. Use of semiquantitative lateral flow immunoassays (LFIAs) may allow a more rapid detection procedure with

  9. A Switchable Linker-Based Immunoassay for Ultrasensitive Visible Detection of Salmonella in Tomatoes.

    Science.gov (United States)

    Hahn, Jungwoo; Kim, Eunghee; You, Young Sang; Gunasekaran, Sundaram; Lim, Seokwon; Choi, Young Jin

    2017-10-01

    On-site detection for sensitive identification of foodborne pathogens on fresh produce with minimal use of specialized instrumentation is crucial to the food industry. A switchable linker (SL)-based immunoassay was designed for ultrasensitive on-site detection of Salmonella in tomato samples. The assay is based on large-scale aggregation of gold nanoparticles (GNPs), induced by a quantitative relationship among the biotinylated Salmonella polyclonal antibody (b-Ab) used as the SL, the functionalized GNPs, and Salmonella. Important factors such as the concentration of SLs, time required for large-scale aggregation, and selectivity of b-Ab were optimized to minimize the detection time (within 45 min with gentle agitation) and achieve the lowest limit of detection (LOD; 10 CFU/g in tomato samples) possible. This SL-based immunoassay with its relatively low LOD and short detection time may meet the need for rapid, simple, on-site analysis of pathogens in fresh produce. The novel switchable linker-based immunoassay is a rapid, specific, and sensitive method that has potential applications for routine diagnostics of Salmonella in tomato products. These advantages make it a practical approach for general use in the processing industry to detect Salmonella rapidly and to implement appropriate regulatory procedures. Furthermore, it could be applied to other fresh products including cantaloupe, strawberry, and cucumbers. © 2017 Institute of Food Technologists®.

  10. Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies

    NARCIS (Netherlands)

    J. Groen (Jan); P. Koraka (Penelope); J. Velzing (Jans); C. Copra (Cederick); A.D.M.E. Osterhaus (Albert)

    2000-01-01

    textabstractThe performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid

  11. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Directory of Open Access Journals (Sweden)

    Ratthaphol Charlermroj

    Full Text Available Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac, chilli vein-banding mottle virus (CVbMV, potyvirus, watermelon silver mottle virus (WSMoV, tospovirus serogroup IV and melon yellow spot virus (MYSV, tospovirus. An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour was much shorter than that of ELISA (4 hours. This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  12. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Kumpoosiri, Mallika; Warin, Nuchnard; Oplatowska, Michalina; Gajanandana, Oraprapai; Grant, Irene R; Karoonuthaisiri, Nitsara; Elliott, Christopher T

    2013-01-01

    Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), chilli vein-banding mottle virus (CVbMV, potyvirus), watermelon silver mottle virus (WSMoV, tospovirus serogroup IV) and melon yellow spot virus (MYSV, tospovirus). An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE)-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA) when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour) was much shorter than that of ELISA (4 hours). This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  13. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays: applications, fundamentals, and optimization

    International Nuclear Information System (INIS)

    Jeremy Daniel Driskell

    2006-01-01

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  14. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays. Applications, fundamentals, and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Driskell, Jeremy Daniel [Iowa State Univ., Ames, IA (United States)

    2006-08-09

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  15. Immunoassays in Biotechnology

    Science.gov (United States)

    Immunoassays have broad applications for a wide variety of important biological compounds and environmental contaminants. Immunoassays can detect the presence of an antigen in the human body, a pollutant in the environment, or a critical antibody in a patient’s serum to develop a...

  16. Immunological detection of small organic molecules in the presence of perchlorates: relevance to the life marker chip and life detection on Mars.

    Science.gov (United States)

    Rix, Catherine S; Sims, Mark R; Cullen, David C

    2011-11-01

    The proposed ExoMars mission, due to launch in 2018, aims to look for evidence of extant and extinct life in martian rocks and regolith. Previous attempts to detect organic molecules of biological or abiotic origin on Mars have been unsuccessful, which may be attributable to destruction of these molecules by perchlorate salts during pyrolysis sample extraction techniques. Organic molecules can also be extracted and measured with solvent-based systems. The ExoMars payload includes the Life Marker Chip (LMC) instrument, capable of detecting biomarker molecules of extant and extinct Earth-like life in liquid extracts of martian samples with an antibody microarray assay. The aim of the work reported here was to investigate whether the presence of perchlorate salts, at levels similar to those at the NASA Phoenix landing site, would compromise the LMC extraction and detection method. To test this, we implemented an LMC-representative sample extraction process with an LMC-representative antibody assay and used these to extract and analyze a model sample that consisted of a Mars analog sample matrix (JSC Mars-1) spiked with a representative organic molecular target (pyrene, an example of abiotic meteoritic infall targets) in the presence of perchlorate salts. We found no significant change in immunoassay function when using pyrene standards with added perchlorate salts. When model samples spiked with perchlorate salts were subjected to an LMC-representative liquid extraction, immunoassays functioned in a liquid extract and detected extracted pyrene. For the same model sample matrix without perchlorate salts, we observed anomalous assay signals that coincided with yellow coloration of the extracts. This unexpected observation is being studied further. This initial study indicates that the presence of perchlorate salts, at levels similar to those detected at the NASA Phoenix landing site, is unlikely to prevent the LMC from extracting and detecting organic molecules from

  17. Nitrocellulose membrane-based enzyme-linked immunoassay for dengue serotype-1 IgM detection

    International Nuclear Information System (INIS)

    Leon, S.; Guevara, C.; Chunga, A.

    1999-01-01

    To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1 (DEN1) infected patients, and 48 from healthy subjects. Both groups were tested with a nitrocellulose membrane-based IgM capture enzyme immunoassay (NMB-EIA) and also with an ELISA as referential pattern. NMB-EIA testing detected IgM anti-DEN1 in 94,34% of samples from infected patients, and in 14,58% of control samples, whereas ELISA fails to report false positive or false negative results: NMB-EIA appears to be a good alternative for dengue infection diagnosis. (authors)

  18. Fast and sensitive detection of enteropathogenic Yersinia by immunoassays.

    Science.gov (United States)

    Laporte, Jérôme; Savin, Cyril; Lamourette, Patricia; Devilliers, Karine; Volland, Hervé; Carniel, Elisabeth; Créminon, Christophe; Simon, Stéphanie

    2015-01-01

    Yersinia enterocolitica and Yersinia pseudotuberculosis, the two Yersinia species that are enteropathogenic for humans, are distributed worldwide and frequently cause diarrhea in inhabitants of temperate and cold countries. Y. enterocolitica is a major cause of foodborne disease resulting from consumption of contaminated pork meat and is further associated with substantial economic cost. However, investigation of enteropathogenic Yersinia species is infrequently performed routinely in clinical laboratories because of their specific growth characteristics, which make difficult their isolation from stool samples. Moreover, current isolation procedures are time-consuming and expensive, thus leading to underestimates of the incidence of enteric yersiniosis, inappropriate prescriptions of antibiotic treatments, and unnecessary appendectomies. The main objective of the study was to develop fast, sensitive, specific, and easy-to-use immunoassays, useful for both human and veterinary diagnosis. Monoclonal antibodies (MAbs) directed against Y. enterocolitica bioserotypes 2/O:9 and 4/O:3 and Y. pseudotuberculosis serotypes I and III were produced. Pairs of MAbs were selected by testing their specificity and affinity for enteropathogenic Yersinia and other commonly found enterobacteria. Pairs of MAbs were selected to develop highly sensitive enzyme immunoassays (EIAs) and lateral flow immunoassays (LFIs or dipsticks) convenient for the purpose of rapid diagnosis. The limit of detection of the EIAs ranged from 3.2 × 10(3) CFU/ml to 8.8 × 10(4) CFU/ml for pathogenic serotypes I and III of Y. pseudotuberculosis and pathogenic bioserotypes 2/O:9 and 4/O:3 of Y. enterocolitica and for the LFIs ranged from 10(5) CFU/ml to 10(6) CFU/ml. A similar limit of detection was observed for artificially contaminated human feces. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries.

    Science.gov (United States)

    Pilavaki, Evdokia; Demosthenous, Andreas

    2017-11-20

    Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  20. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries

    Directory of Open Access Journals (Sweden)

    Evdokia Pilavaki

    2017-11-01

    Full Text Available Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  1. Detection of Avian Influenza Virus by Fluorescent DNA Barcode-based Immunoassay with Sensitivity Comparable to PCR

    DEFF Research Database (Denmark)

    Cao, Cuong; Dhumpa, Raghuram; Bang, Dang Duong

    2010-01-01

    involves the sandwiching of the target AIV between magnetic immunoprobes and barcode-carrying immunoprobes. Because each barcode-carrying immunoprobe is functionalized with a multitude of fluorophore-DNA barcode strands, many DNA barcodes are released for each positive binding event resulting......In this paper, a coupling of fluorophore-DNA barcode and bead-based immunoassay for detecting avian influenza virus (AIV) with PCR-like sensitivity is reported. The assay is based on the use of sandwich immunoassay and fluorophore-tagged oligonucleotides as representative barcodes. The detection...

  2. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    Directory of Open Access Journals (Sweden)

    Na Kong

    2015-04-01

    Full Text Available An indirect competitive enzyme-linked immunosorbent assay (icELISA and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  3. Direct biosensor immunoassays for the detection of nonmilk proteins in milk powder

    NARCIS (Netherlands)

    Haasnoot, W.; Olieman, K.; Cazemier, G.; Verheijen, R.

    2001-01-01

    The low prices of some nonmilk proteins make them attractive as potential adulterants in dairy products. An optical biosensor (BIACORE 3000) was used to develop a direct and combined biosensor immunoassay (BIA) for the simultaneous detection of soy, pea, and soluble wheat proteins in milk powders.

  4. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Xiaoling Fu

    2018-03-01

    Full Text Available The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA was presented for the clinical determination and analysis of human epididymis protein 4 (HE4 in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA, with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum. Keywords: Chemiluminescence immunoassay, Magnetic particles, Human epididymis protein 4

  5. A study using an isotope probe comparing immunoassay with serology in detection of Brucella Abortus antibody

    International Nuclear Information System (INIS)

    Devlin, J.G.; Redington, F.; Stephenson, M.

    1986-01-01

    We report a comparison of radio-immunoassay with conventional serology in the detection of brucella abortus antibody from three laboratories. Overall agreement by Chi squared analysis is 5%. There are significant differences between laboratories and a significant number of sero negative suspect sera (from 20% - 60%) were positive by ratio-immunoassay test. We suspect that conventional serology under-reports the incidence of antibody to brucella abortus. (author)

  6. A competitive enzyme immunoassay for the quantitative detection of cocaine from banknotes and latent fingermarks.

    Science.gov (United States)

    van der Heide, Susan; Garcia Calavia, Paula; Hardwick, Sheila; Hudson, Simon; Wolff, Kim; Russell, David A

    2015-05-01

    A sensitive and versatile competitive enzyme immunoassay (cEIA) has been developed for the quantitative detection of cocaine in complex forensic samples. Polyclonal anti-cocaine antibody was purified from serum and deposited onto microtiter plates. The concentration of the cocaine antibody adsorbed onto the plates, and the dilution of the cocaine-HRP hapten were both studied to achieve an optimised immunoassay. The method was successfully used to quantify cocaine in extracts taken from both paper currency and latent fingermarks. The limit of detection (LOD) of 0.162ngmL(-1) achieved with the assay compares favourably to that of conventional chromatography-mass spectroscopy techniques, with an appropriate sensitivity for the quantification of cocaine at the low concentrations present in some forensic samples. The cEIA was directly compared to LC-MS for the analysis of ten UK banknote samples. The results obtained from both techniques were statistically similar, suggesting that the immunoassay was unaffected by cross-reactivity with potentially interfering compounds. The cEIA was used also for the detection of cocaine in extracts from latent fingermarks. The results obtained were compared to the cocaine concentrations detected in oral fluid sampled from the same individual. Using the cEIA, we have shown, for the first time, that endogeneously excreted cocaine can be detected and quantified from a single latent fingermark. Additionally, it has been shown that the presence of cocaine, at similar concentrations, in more than one latent fingermark from the same individual can be linked with those concentrations found in oral fluid. These results show that detection of drugs in latent fingermarks could directly indicate whether an individual has consumed the drug. The specificity and feasibility of measuring low concentrations of cocaine in complex forensic samples demonstrate the effectiveness and robustness of the assay. The immunoassay presents a simple and cost

  7. Single biosensor immunoassay for the detection of five aminoglycosides in reconstituted skimmed milk

    NARCIS (Netherlands)

    Haasnoot, W.; Cazemier, G.; Koets, M.; Amerongen, van A.

    2003-01-01

    The application of an optical biosensor (Biacore 3000), with four flow channels (Fcs), in combination with a mixture of four specific antibodies resulted in a competitive inhibition biosensor immunoassay (BIA) for the simultaneous detection of the five relevant aminoglycosides in reconstituted

  8. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flas...

  9. Flotation Immunoassay: Masking the Signal from Free Reporters in Sandwich Immunoassays.

    Science.gov (United States)

    Chen, Hui; Hagström, Anna E V; Kim, Jinsu; Garvey, Gavin; Paterson, Andrew; Ruiz-Ruiz, Federico; Raja, Balakrishnan; Strych, Ulrich; Rito-Palomares, Marco; Kourentzi, Katerina; Conrad, Jacinta C; Atmar, Robert L; Willson, Richard C

    2016-04-14

    In this work, we demonstrate that signal-masking reagents together with appropriate capture antibody carriers can eliminate the washing steps in sandwich immunoassays. A flotation immunoassay (FI) platform was developed with horseradish peroxidase chemiluminescence as the reporter system, the dye Brilliant Blue FCF as the signal-masking reagent, and buoyant silica micro-bubbles as the capture antibody carriers. Only reporters captured on micro-bubbles float above the dye and become visible in an analyte-dependent manner. These FIs are capable of detecting proteins down to attomole levels and as few as 10(6) virus particles. This signal-masking strategy represents a novel approach to simple, sensitive and quantitative immunoassays in both laboratory and point-of-care settings.

  10. Nanobody-based electrochemical immunoassay for Bacillus thuringiensis Cry1Ab toxin by detecting the enzymatic formation of polyaniline

    International Nuclear Information System (INIS)

    Zhu, Min; Li, Guanghui; Li, Min; Zhou, Zikai; Liu, Hong; Lei, Hongtao; Shen, Yanfei; Wan, Yakun

    2015-01-01

    We describe an electrochemical immunoassay for the Cry1Ab toxin that is produced by Bacillus thuringiensis. It is making use of a nanobody (a heavy-chain only antibody) that was selected from an immune phage displayed library. A biotinylated primary nanobody and a HRP-conjugated secondary nanobody were applied in a sandwich immunoassay where horseradish peroxidase (HRP) is used to produce polyaniline (PANI) from aniline. PANI can be easily detected by differential pulse voltammetry at a working voltage as low as 40 mV (vs. Ag/AgCl) which makes the assay fairly selective. This immunoassay for Cry1Ab has an analytical range from 0.1 to 1000 ng∙mL -1 and a 0.07 ng∙mL -1 lower limit of detection. The average recoveries of the toxin from spiked samples are in the range from 102 to 114 %, with a relative standard deviation of <7.5 %. The results demonstrated that the assay represented an attractive alternative to existing immunoassays in enabling affordable, sensitive, robust and specific determination of this toxin. (author)

  11. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng....../L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED...... excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems....

  12. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays.

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-09-19

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.

  13. Plasmon enhanced fluoro-immunoassay using egg yolk antibodies for ultra-sensitive detection of herbicide diuron.

    Science.gov (United States)

    Sharma, Priyanka; Kukkar, Manil; Ganguli, Ashok K; Bhasin, Aman; Suri, C Raman

    2013-08-07

    Plasmon enhanced fluorescence immunoassay (PEFI) format has been reported in developing a sensitive heterogeneous fluoroimmunoassay for monitoring the phenylurea herbicide diuron. Computer-assisted molecular modeling was carried out to study the conformational and electrostatic effects of synthesized hapten for producing highly specific egg yolk antibody against a phenyl urea herbicide diuron. The generated antibodies were labeled with fluorescein isothiocyanate at different molar ratios and used as tracer in the developed fluorescence based immunoassay. The sensitivity of the assay format was enhanced by using silver nanoparticles tagged with bovine serum albumin as a new blocking reagent in the developed PEFI format. Enhancer treatment on the developed immunoassay showed a significant improvement of fluorescence signal intensity with approximately 10 fold increase in assay sensitivity. The immunoassay has a detection limit of 0.01 ng mL(-1) with good signal precision (~2%) in the optimum working concentration range between 1 pg mL(-1) to 10 μg mL(-1) of diuron. These findings facilitate high throughput fluorescence-based processes that could be useful in biology, drug discovery and compound screening applications.

  14. Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin

    Directory of Open Access Journals (Sweden)

    Sultana Akter

    2017-09-01

    Full Text Available Nodularin (NOD is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A phage display technique was utilized to interrogate a synthetic antibody phage library for binders recognizing NOD bound to an anti-ADDA (3-Amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4(E,6(E-dienoic acid monoclonal antibody (Mab. One of the obtained immunocomplex binders, designated SA32C11, showed very high specificity towards nodularin-R (NOD-R over to the tested 10 different microcystins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF, -LW, -LA, -WR. It was expressed in Escherichia coli as a single chain antibody fragment (scFv fusion protein and used to establish a time-resolved fluorometry-based assay in combination with the anti-ADDA Mab. The detection limit (blank + 3SD of the immunoassay, with a total assay time of 1 h 10 min, is 0.03 µg/L of NOD-R. This represents the most sensitive immunoassay method for the specific detection of NOD reported so far. The assay was tested for its performance to detect NOD using spiked (0.1 to 3 µg/L of NOD-R water samples including brackish sea and coastal water and the recovery ranged from 79 to 127%. Furthermore, a panel of environmental samples, including water from different sources, fish and other marine tissue specimens, were analyzed for NOD using the assay. The assay has potential as a rapid screening tool for the analysis of a large number of water samples for the presence of NOD. It can also find applications in the analysis of the bioaccumulation of NOD in marine organisms and in the food chain.

  15. Rapid micromotor-based naked-eye immunoassay.

    Science.gov (United States)

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    Science.gov (United States)

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  17. Development of nanobody-based flow injection chemiluminescence immunoassay for sensitive detection of human prealbumin.

    Science.gov (United States)

    Ma, Lei; Sun, Yanyan; Kang, Xuejun; Wan, Yakun

    2014-11-15

    Nanobodies, derived from camelid heavy-chain antibodies, have novel and impactful applications in clinical diagnostics. Our objective is to develop a nanobody-based chemiluminescence immunoassay for sensitive detection of human prealbumin (PA). In this context, a phage display nanobody library is constructed via immunizing dromedary camel with human prealbumin. Three nanobodies have been identified by five successive bio-panning steps. Based on their high expression level and good affinity, two out of three are chosen for further study. Magnetic beads (MBs) were functionalized with PEI by acylamide bond formed between the carboxyl group on the surface of the MB. Then, an anti-PA nanobody (Nb1) can be effectively immobilized onto the surface of the functionalized MB using glutaradehyde as the link. The modified MBs with Nb1 can specifically capture the target PA and reacted with silica nanoparticles with co-immobilized HRP and anti-PA nanobody (Nb2). The concentration of PA was detected by flow injection chemiluminescence. When using MB/PEI as the carrier of anti-PA Nb1, the CL signal significantly increased to 4-fold compared with the signal using MB without PEI modification. The CL signal was further amplified to 5-fold when Si/Nb2 was used as the signal probe. Under optimized conditions, the present immunoassay exhibited a wide quantitative range from 0.05 to 1000 μg L(-1) with a detection limit of 0.01 μg L(-1). The sensitivity of the proposed immunoassay offers great promises in providing a sensitive, specific, time saving, and potential method for detecting PA in clinical settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    International Nuclear Information System (INIS)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong; Shi, Hanchang; Long, Feng

    2016-01-01

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  19. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  20. Integrated immunoassay using tuneable surface acoustic waves and lensfree detection.

    Science.gov (United States)

    Bourquin, Yannyk; Reboud, Julien; Wilson, Rab; Zhang, Yi; Cooper, Jonathan M

    2011-08-21

    The diagnosis of infectious diseases in the Developing World is technologically challenging requiring complex biological assays with a high analytical performance, at minimal cost. By using an opto-acoustic immunoassay technology, integrating components commonly used in mobile phone technologies, including surface acoustic wave (SAW) transducers to provide pressure driven flow and a CMOS camera to enable lensfree detection technique, we demonstrate the potential to produce such an assay. To achieve this, antibody functionalised microparticles were manipulated on a low-cost disposable cartridge using the surface acoustic waves and were then detected optically. Our results show that the biomarker, interferon-γ, used for the diagnosis of diseases such as latent tuberculosis, can be detected at pM concentrations, within a few minutes (giving high sensitivity at a minimal cost). This journal is © The Royal Society of Chemistry 2011

  1. Lateral Flow Immunoassays for Ebola Virus Disease Detection in Liberia.

    Science.gov (United States)

    Phan, Jill C; Pettitt, James; George, Josiah S; Fakoli, Lawrence S; Taweh, Fahn M; Bateman, Stacey L; Bennett, Richard S; Norris, Sarah L; Spinnler, David A; Pimentel, Guillermo; Sahr, Phillip K; Bolay, Fatorma K; Schoepp, Randal J

    2016-10-15

    Lateral flow immunoassays (LFIs) are point-of-care diagnostic assays that are designed for single use outside a formal laboratory, with in-home pregnancy tests the best-known example of these tests. Although the LFI has some limitations over more-complex immunoassay procedures, such as reduced sensitivity and the potential for false-positive results when using complex sample matrices, the assay has the benefits of a rapid time to result and ease of use. These benefits make it an attractive option for obtaining rapid results in an austere environment. In an outbreak of any magnitude, a field-based rapid diagnostic assay would allow proper patient transport and for safe burials to be conducted without the delay caused by transport of samples between remote villages and testing facilities. Use of such point-of-care instruments in the ongoing Ebola virus disease (EVD) outbreak in West Africa would have distinct advantages in control and prevention of local outbreaks, but proper understanding of the technology and interpretation of results are important. In this study, a LFI, originally developed by the Naval Medical Research Center for Ebola virus environmental testing, was evaluated for its ability to detect the virus in clinical samples in Liberia. Clinical blood and plasma samples and post mortem oral swabs submitted to the Liberian Institute for Biomedical Research, the National Public Health Reference Laboratory for EVD testing, were tested and compared to results of real-time reverse transcription-polymerase chain reaction (rRT-PCR), using assays targeting Ebola virus glycoprotein and nucleoprotein. The LFI findings correlated well with those of the real-time RT-PCR assays used as benchmarks. Rapid antigen-detection tests such as LFIs are attractive alternatives to traditional immunoassays but have reduced sensitivity and specificity, resulting in increases in false-positive and false-negative results. An understanding of the strengths, weaknesses, and

  2. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  3. Detection of hidden hazelnut protein in food by IgY-based indirect competitive enzyme-immunoassay

    NARCIS (Netherlands)

    Baumgartner, S.; Bremer, M.G.E.G.; Kemmers - Voncken, A.E.M.; Smits, N.G.E.; Haasnoot, W.; Banks, J.; Reece, P.; Danks, C.; Tomkies, V.; Immer, U.; Schmitt, K.; Krska, R.

    2004-01-01

    The development of an indirect competitive enzyme-immunoassay for the detection of hidden hazelnut protein in complex food matrices is described. A sensitive and selective polyclonal antibody was raised by immunisation of laying hens with protein extracts from roasted hazelnuts. In contrast to

  4. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer.

    Science.gov (United States)

    Fu, Xiaoling; Liu, Yangyang; Qiu, Ruiyun; Foda, Mohamed F; Zhang, Yong; Wang, Tao; Li, Jinshan

    2018-03-01

    The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0-1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.

  5. Magnetic bead and gold nanoparticle probes based immunoassay for β-casein detection in bovine milk samples.

    Science.gov (United States)

    Li, Y S; Meng, X Y; Zhou, Y; Zhang, Y Y; Meng, X M; Yang, L; Hu, P; Lu, S Y; Ren, H L; Liu, Z S; Wang, X R

    2015-04-15

    In this work, a double-probe based immunoassay was developed for rapid and sensitive determination of β-casein in bovine milk samples. In the method, magnetic beads (MBs), employed as supports for the immobilization of anti-β-casein polyclonal antibody (PAb), were used as the capture probe. Colloidal gold nanoparticles (AuNPs), employed as a bridge for loading anti-β-casein monoclonal antibody (McAb) and horseradish peroxidase (HRP), were used as the amplification probe. The presence of β-casein causes the sandwich structures of MBs-PAb-β-casein-McAb-AuNPs through the interaction between β-casein and the anti-β-casein antibodies. The HRP, used as an enzymatic-amplified tracer, can catalytically oxidize the substrate 3,3',5,5'-tetramethylbenzidine (TMB), generating optical signals that are proportional to the quantity of β-casein. The linear range of the immunoassay was from 6.5 to 1520ngmL(-1). The limit of detection (LOD) was 4.8ngmL(-1) which was 700 times lower than that of MBs-antibody-HRP based immunoassay and 6-7 times lower than that from the microplate-antibody-HRP based assay. The recoveries of β-casein from bovine milk samples were from 95.0% to 104.3% that had a good correlation coefficient (R(2)=0.9956) with those obtained by an official standard Kjeldahl method. For higher sensitivity, simple sample pretreatment and shorter time requirement of the antigen-antibody reaction, the developed immunoassay demonstrated the viability for detection of β-casein in bovine milk samples. Copyright © 2014. Published by Elsevier B.V.

  6. Development of an ultrasensitive immunoassay for detecting tartrazine.

    Science.gov (United States)

    Li, Zhuokun; Song, Shanshan; Xu, Liguang; Kuang, Hua; Guo, Shidong; Xu, Chuanlai

    2013-06-25

    We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  7. Targeted deposition of antibodies on a multiplex CMOS microarray and optimization of a sensitive immunoassay using electrochemical detection.

    Directory of Open Access Journals (Sweden)

    John Cooper

    2010-03-01

    Full Text Available The CombiMatrix ElectraSense microarray is a highly multiplex, complementary metal oxide semiconductor with 12,544 electrodes that are individually addressable. This platform is commercially available as a custom DNA microarray; and, in this configuration, it has also been used to tether antibodies (Abs specifically on electrodes using complementary DNA sequences conjugated to the Abs.An empirical method is described for developing and optimizing immunoassays on the CombiMatrix ElectraSense microarray based upon targeted deposition of polypyrrole (Ppy and capture Ab. This process was automated using instrumentation that can selectively apply a potential or current to individual electrodes and also measure current generated at the electrodes by an enzyme-enhanced electrochemical (ECD reaction. By designating groups of electrodes on the array for different Ppy deposition conditions, we determined that the sensitivity and specificity of a sandwich immunoassay for staphylococcal enterotoxin B (SEB is influenced by the application of different voltages or currents and the application time. The sandwich immunoassay used a capture Ab adsorbed to the Ppy and a reporter Ab labeled for fluorescence detection or ECD, and results from these methods of detection were different.Using Ppy deposition conditions for optimum results, the lower limit of detection for SEB using the ECD assay was between 0.003 and 0.01 pg/ml, which represents an order of magnitude improvement over a conventional enzyme-linked immunosorbant assay. In the absence of understanding the variables and complexities that affect assay performance, this highly multiplexed electrode array provided a rapid, high throughput, and empirical approach for developing a sensitive immunoassay.

  8. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    Science.gov (United States)

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  9. Comparison of capillary electrophoresis-based immunoassay with fluorescence polarization immunoassay for the immunodetermination of methamphetamine using various methamphetamine antibodies.

    Science.gov (United States)

    Choi, J; Kim, C; Choi, M J

    1998-11-01

    An accurate and simple immunoassay using capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was performed for the detection of methamphetamine (MA) in urine. The CE-LIF was conducted with an untreated fused-silica column using antiserum and a tracer of fluorescein isothiocyanate (FITC)-labeled MA. This CE-LIF system was compared with fluorescence polarization immunoassay (FPIA) in a TDx analyzer in the photo-check mode using the same FITC-labeled tracer and the same antiserum. Various antibodies, not only those prepared by our own immunogens but also those from commercial sources, were screened and characterized in both assay systems with regard to sensitivity, precision, and cross-reactivity. Both systems satisfied analytical precision and gave similar cross-reactivity patterns. However, the CE-LIF-based immunoassay was approximately one order superior to FPIA in sensitivity, requiring less volume of sample, antiserum, and tracer for the assay. Considering that the FPIA system is well known to be a useful tool for screening antibodies and detecting drugs, the CE-LIF-based immunoassay system, which is seemingly more advantageous than the FPIA system, appears to have great power for the characterization of antibodies and for the detection of MA in urine.

  10. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3

    Directory of Open Access Journals (Sweden)

    Qian-Yun Zhang

    2011-08-01

    Full Text Available Glypican-3 (GPC3 is reported as a great promising tumor marker for hepatocellular carcinoma (HCC diagnosis. Highly sensitive and accurate analysis of serum GPC3 (sGPC3, in combination with or instead of traditional HCC marker alpha-fetoprotein (AFP, is essential for early diagnosis of HCC. Biomaterial-functionalized magnetic particles have been utilized as solid supports with good biological compatibility for sensitive immunoassay. Here, the magnetic nanoparticles (MnPs and magnetic microparticles (MmPs with carboxyl groups were further modified with streptavidin, and applied for the development of chemiluminescence enzyme immunoassay (CLEIA. After comparing between MnPs- and MmPs-based CLEIA, MnPs-based CLEIA was proved to be a better method with less assay time, greater sensitivity, better linearity and longer chemiluminescence platform. MnPs-based CLEIA was applied for detection of sGPC3 in normal liver, hepatocirrhosis, secondary liver cancer and HCC serum samples. The results indicated that sGPC3 was effective in diagnosis of HCC with high performance. Keywords: Magnetic nanoparticle, Magnetic microparticle, Chemiluminescence enzyme immunoassay, Glypican-3, Hepatocellular carcinoma

  11. Materials for Microfluidic Immunoassays: A Review.

    Science.gov (United States)

    Mou, Lei; Jiang, Xingyu

    2017-08-01

    Conventional immunoassays suffer from at least one of these following limitations: long processing time, high costs, poor user-friendliness, technical complexity, poor sensitivity and specificity. Microfluidics, a technology characterized by the engineered manipulation of fluids in channels with characteristic lengthscale of tens of micrometers, has shown considerable promise for improving immunoassays that could overcome these limitations in medical diagnostics and biology research. The combination of microfluidics and immunoassay can detect biomarkers with faster assay time, reduced volumes of reagents, lower power requirements, and higher levels of integration and automation compared to traditional approaches. This review focuses on the materials-related aspects of the recent advances in microfluidics-based immunoassays for point-of-care (POC) diagnostics of biomarkers. We compare the materials for microfluidic chips fabrication in five aspects: fabrication, integration, function, modification and cost, and describe their advantages and drawbacks. In addition, we review materials for modifying antibodies to improve the performance of the reaction of immunoassay. We also review the state of the art in microfluidic immunoassays POC platforms, from the laboratory to routine clinical practice, and also commercial products in the market. Finally, we discuss the current challenges and future developments in microfluidic immunoassays. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Development of an Ultrasensitive Immunoassay for Detecting Tartrazine

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-06-01

    Full Text Available We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  13. Development of a mass spectrometry immunoassay for unambiguous detection of egg allergen traces in wines.

    Science.gov (United States)

    Pilolli, Rosa; Chaudhari, Ravindra; Palmisano, Francesco; Monaci, Linda

    2017-02-01

    A mass spectrometry immunoassay (MSIA) specifically designed for the detection of egg allergens in wines is described. MSIA is based on an immunoaffinity enrichment procedure combined with targeted MS/MS detection of selected egg peptide markers. Polyclonal antibodies raised against native ovalbumin, chosen as the target protein tracing for egg powder, were immobilized onto low backpressure monolithic MSIA customized disposable tips. Ovalbumin-free wine samples were fortified with standard protein at different concentrations in the low microgram-per-milliliter range. A simple protocol was devised consisting of a 1:4 dilution of the wine sample with a basic solution for pH adjustment, followed by a semi-automated purification/enrichment step on MSIA customized disposable tips fitted on a multichannel electronic pipette. Among the main figures of merit, LOD and LOQ values as low as 0.01 and 0.03 μg/mL, respectively, and within-day precision of 18% should be noticed. Noteworthy, the developed assay outperformed current MS-based methods for the detection of allergenic protein in wine matrices, thanks to the immunoaffinity enrichment. In addition, compared to other immunoassays, the present approach boasts the unquestionable advantage of providing an unambiguous identification of the target protein by simultaneous detection of three unique peptide markers each giving three specific MS/MS transitions.

  14. Development of a Nanobody-Based Lateral Flow Immunoassay for Detection of Human Norovirus.

    Science.gov (United States)

    Doerflinger, Sylvie Y; Tabatabai, Julia; Schnitzler, Paul; Farah, Carlo; Rameil, Steffen; Sander, Peter; Koromyslova, Anna; Hansman, Grant S

    2016-01-01

    Human noroviruses are the dominant cause of outbreaks of acute gastroenteritis. These viruses are usually detected by molecular methods, including reverse transcriptase PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA). Human noroviruses are genetically and antigenically diverse, with two main genogroups that are further subdivided into over 40 different genotypes. During the past decade, genogroup 2 genotype 4 (GII.4) has dominated in most countries, but recently, viruses belonging to GII.17 have increased in prevalence in a number of countries. A number of commercially available ELISAs and lateral flow immunoassays were found to have lower sensitivities to the GII.17 viruses, indicating that the antibodies used in these methods may not have a high level of cross-reactivity. In this study, we developed a rapid Nanobody-based lateral flow immunoassay (Nano-immunochromatography [Nano-IC]) for the detection of human norovirus in clinical specimens. The Nano-IC assay detected virions from two GII.4 norovirus clusters, which included the current dominant strain and a novel variant strain. The Nano-IC method had a sensitivity of 80% and specificity of 86% for outbreak specimens. Norovirus virus-like particles (VLPs) representing four genotypes (GII.4, GII.10, GII.12, and GII.17) could be detected by this method, demonstrating the potential in clinical screening. However, further modifications to the Nano-IC method are needed in order to improve this sensitivity, which may be achieved by the addition of other broadly reactive Nanobodies to the system. IMPORTANCE We previously identified a Nanobody (termed Nano-85) that bound to a highly conserved region on the norovirus capsid. In this study, the Nanobody was biotinylated and gold conjugated for a lateral flow immunoassay (termed Nano-IC). We showed that the Nano-IC assay was capable of detecting at least four antigenically distinct GII genotypes, including the newly emerging GII.17. In the clinical setting, the

  15. Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli

    Science.gov (United States)

    Bozkurt, Akif Goktug; Buyukgoz, Guluzar Gorkem; Soforoglu, Mehmet; Tamer, Ugur; Suludere, Zekiye; Boyaci, Ismail Hakki

    2018-04-01

    In this study, a sandwich immunoassay method utilizing enzymatic activity of alkaline phosphatase (ALP) on 5-bromo-4-chloro-3-indolyl phosphate (BCIP) for Escherichia coli (E. coli) detection was developed using surface enhanced Raman spectroscopy (SERS). For this purpose, spherical magnetic gold coated core-shell nanoparticles (MNPs-Au) and rod shape gold nanoparticles (Au-NRs) were synthesized and modified for immunomagnetic separation (IMS) of E. coli from the solution. In order to specify the developed method to ALP activity, Au-NRs were labeled with this enzyme. After successful construction of the immunoassay, BCIP substrate was added to produce the SERS-active product; 5-bromo-4-chloro-3-indole (BCI). A good linearity (R2 = 0.992) was established between the specific SERS intensity of BCI at 600 cm- 1 and logarithmic E. coli concentration in the range of 1.7 × 101-1.7 × 106 cfu mL- 1. LOD and LOQ values were also calculated and found to be 10 cfu mL- 1 and 30 cfu mL- 1, respectively.

  16. Bead-based immunoassays

    NARCIS (Netherlands)

    Wal, van der F.J.; Bergervoet, J.H.W.; Achterberg, R.P.; Haasnoot, W.

    2014-01-01

    Since the first immunoassay with (radioactive) labeled antibodies in the middle of the 20th century [1], many different formats on various platforms have been developed, using antibodies for capture and/or detection. If antibodies are used to capture compounds, a support, such as the wall of a

  17. Positive predictive value of the immunoassay for Clostridium difficile toxin A and B detection at a private hospital.

    Science.gov (United States)

    Pérez-Topete, S E; Miranda-Aquino, T; Hernández-Portales, J A

    Clostridium difficile (C. difficile) is a Gram-positive bacillus that is a common cause of diarrhea in the hospital environment, with a documented incidence of up to 10%. There are different methods to detect it, but a widely used test in our environment is the immunoassay for toxins A and B. The aim of our study was to 1) estimate the positive predictive value of the immunoassay for the detection of the C. difficile toxins A and B, 2) to establish the incidence of C. difficile-associated diarrhea in the hospital, and 3) to know the most common associated factors. A diagnostic test accuracy study was conducted within the time frame of January 2010 to August 2013 at the Hospital Christus Muguerza® Alta Especialidad on patients with symptoms suggestive of C. difficile-associated diarrhea that had a positive immunoassay test and confirmation of C. difficile through colon biopsy and stool culture. The immunoassay for toxins A and B was performed in 360 patients. Fifty-five of the cases had positive results, 35 of which showed the presence of C. difficile. Incidence was 10.2% and the positive predictive value of the test for C. difficile toxins A and B was 0.64 (95% CI, 0.51-0.76). Previous antibiotic therapy (n=29) and proton pump inhibitor use (n=19) were the most common associated factors. C. difficile incidence in our environment is similar to that found in the literature reviewed, but the positive predictive value of the test for toxin A and B detection was low. Copyright © 2016 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  18. Highly sensitive immunoassay of protein molecules based on single nanoparticle fluorescence detection in a nanowell

    Science.gov (United States)

    Han, Jin-Hee; Kim, Hee-Joo; Lakshmana, Sudheendra; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2011-03-01

    A nanoarray based-single molecule detection system was developed for detecting proteins with extremely high sensitivity. The nanoarray was able to effectively trap nanoparticles conjugated with biological sample into nanowells by integrating with an electrophoretic particle entrapment system (EPES). The nanoarray/EPES is superior to other biosensor using immunoassays in terms of saving the amounts of biological solution and enhancing kinetics of antibody binding due to reduced steric hindrance from the neighboring biological molecules. The nanoarray patterned onto a layer of PMMA and LOL on conductive and transparent indium tin oxide (ITO)-glass slide by using e-beam lithography. The suspension of 500 nm-fluorescent (green emission)-carboxylated polystyrene (PS) particles coated with protein-A followed by BDE 47 polyclonal antibody was added to the chip that was connected to the positive voltage. The droplet was covered by another ITO-coated-glass slide and connected to a ground terminal. After trapping the particles into the nanowells, the solution of different concentrations of anti-rabbit- IgG labeled with Alexa 532 was added for an immunoassay. A single molecule detection system could quantify the anti-rabbit IgG down to atto-mole level by counting photons emitted from the fluorescent dye bound to a single nanoparticle in a nanowell.

  19. Strip-based immunoassay for the simultaneous detection of the neonicotinoid insecticides imidacloprid and thiamethoxam in agricultural products

    Science.gov (United States)

    A semiquantitative strip immunoassay was developed for the rapid detection of imidacloprid and thiamethoxam in agricultural products using specific nanocolloidal gold-labeled monoclonal antibodies. The conjugates of imidacloprid-BSA and thiamethoxam-BSA and goat anti-mouse IgG were coated on the ni...

  20. Solid-Phase Immunoassay of Polystyrene-Encapsulated Semiconductor Coreshells for Cardiac Marker Detection

    Directory of Open Access Journals (Sweden)

    Sanghee Kim

    2012-01-01

    Full Text Available A solid-phase immunoassay of polystyrene-encapsulated semiconductor nanoparticles was demonstrated for cardiac troponin I (cTnI detection. CdSe/ZnS coreshells were encapsulated with a carboxyl-functionalized polystyrene nanoparticle to capture the target antibody through a covalent bonding and to eliminate the photoblinking and toxicity of semiconductor luminescent immunosensor. The polystyrene-encapsulated CdSe/ZnS fluorophores on surface-modified glass chip identified cTnI antigens at the level of ~ng/mL. It was an initial demonstration of diagnostic chip for monitoring a cardiovascular disease.

  1. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  2. A competitive immunoassay for sensitive detection of small molecules chloramphenicol based on luminol functionalized silver nanoprobe.

    Science.gov (United States)

    Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua

    2014-02-17

    Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Inkjet-printed point-of-care immunoassay on a nanoscale polymer brush enables subpicomolar detection of analytes in blood

    Science.gov (United States)

    Joh, Daniel Y.; Hucknall, Angus M.; Wei, Qingshan; Mason, Kelly A.; Lund, Margaret L.; Fontes, Cassio M.; Hill, Ryan T.; Blair, Rebecca; Zimmers, Zackary; Achar, Rohan K.; Tseng, Derek; Gordan, Raluca; Freemark, Michael; Ozcan, Aydogan; Chilkoti, Ashutosh

    2017-08-01

    The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the “D4 assay”) that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are “on-chip,” and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.

  4. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  5. Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels.

    Science.gov (United States)

    Zhu, Shengchao; Zhang, Qin; Guo, Liang-Hong

    2008-08-22

    Fluorescent organic dyes are currently the standard signal-generating labels used in microarray quantification. However, new labeling strategies are needed to meet the demand for high sensitivity in the detection of low-abundance proteins and small molecules. In this report, a long-chain DNA/dye conjugate was used to attach multiple fluorescence labels on antibodies to improve signal intensity and immunoassay sensitivity. Compared with the 30 base-pair (bp) oligonucleotide used in our previous work [Q. Zhang, L.-H. Guo, Bioconjugate Chem. 18 (2007) 1668-1672], conjugation of a 219 bp DNA in solution with a fluorescent DNA binder SYBR Green I resulted in more than sixfold increase in signal intensity, consistent with the increase in bp number. In a direct immunoassay for the detection of goat anti-mouse IgG in a mouse IgG-coated 96-well plate, the long DNA conjugate label also produced higher fluorescence than the short one, accompanied by about 15-fold improvement in the detection limit. To demonstrate its advantage in real applications, the DNA/dye conjugate was employed in the competitive immunoassay of 17beta-estradiol, a clinically and environmentally important analyte. The biotin-terminated DNA was attached to biotinylated anti-estradiol antibody through the biotin/streptavidin/biotin bridge after the immuno-reaction was completed, followed by conjugation with SYBR Green I. The limit of detection for 17beta-estradiol is 1.9 pg mL(-1), which is 200-fold lower than the assay using fluorescein-labeled antibodies. The new multiple labeling strategy uses readily available reagents, and is also compatible with current biochip platform. It has great potential in the sensitive detection of protein and antibody microarrays.

  6. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    International Nuclear Information System (INIS)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-01-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H_2O_2) and H_2O_2-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H_2O_2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H_2O_2, as well as the incubation time between H_2O_2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10"2 CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10"3 CFU/mL to 1.18 × 10"6 CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H_2O_2-sensitive QDs. • The activity of CAT to H_2O_2 is 1000 folds higher than that of the HRP to tetramethylbenzidine. • The limit of detection of the proposed method could

  7. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum......, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based...... on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved...

  8. Nanobody Based Immunoassay for Human Soluble Epoxide Hydrolase Detection Using Polymeric Horseradish Peroxidase (PolyHRP) for Signal Enhancement: The Rediscovery of PolyHRP?

    Science.gov (United States)

    Li, Dongyang; Cui, Yongliang; Morisseau, Christophe; Gee, Shirley J; Bever, Candace S; Liu, Xiangjiang; Wu, Jian; Hammock, Bruce D; Ying, Yibin

    2017-06-06

    Soluble epoxide hydrolase (sEH) is a potential pharmacological target for treating hypertension, vascular inflammation, cancer, pain, and multiple cardiovascular related diseases. A variable domain of the heavy chain antibody (termed single domain antibody (sdAb), nanobody, or VHH) possesses the advantages of small size, high stability, ease of genetic manipulation, and ability for continuous manufacture, making such nanobody a superior choice as an immunoreagent. In this work, we developed an ultrasensitive nanobody based immunoassay for human sEH detection using polymeric horseradish peroxidase (PolyHRP) for signal enhancement. Llama nanobodies against human sEH were used as the detection antibody in sandwich enzyme linked immunosorbent assays (ELISA) with polyclonal anti-sEH as the capture antibody. A conventional sandwich ELISA using a horseradish peroxidase (HRP) labeled anti-hemeagglutinin (HA) tag as the tracer showed a marginal sensitivity (0.0015 optical density (OD)·mL/ng) and limit of detection (LOD) of 3.02 ng/mL. However, the introduction of the PolyHRP as the tracer demonstrated a 141-fold increase in the sensitivity (0.21 OD·mL/ng) and 57-fold decrease in LOD (0.05 ng/mL). Systematic comparison of three different tracers in four ELISA formats demonstrated the overwhelming advantage of PolyHRP as a label for nanobody based immunoassay. This enhanced sEH immunoassay was further evaluated in terms of selectivity against other epoxide hydrolases and detection of the target protein in human tissue homogenate samples. Comparison with an enzyme activity based assay and a Western blot for sEH detection reveals good correlation with the immunoassay. This work demonstrates increased competiveness of nanobodies for practical sEH protein detection utilizing PolyHRP. It is worthwhile to rediscover the promising potential of PolyHRP in nanobody and other affinity based methods after its low-profile existence for decades.

  9. Gliadin Detection in Food by Immunoassay

    Science.gov (United States)

    Grant, Gordon; Sporns, Peter; Hsieh, Y.-H. Peggy

    Immunoassays are very sensitive and efficient tests that are commonly used to identify a specific protein. Examples of applications in the food industry include identification of proteins expressed in genetically modified foods, allergens, or proteins associated with a disease, including celiac disease. This genetic disease is associated with Europeans and affects about one in every 200 people in North America. These individuals react immunologically to wheat proteins, and consequently their own immune systems attack and damage their intestines. This disease can be managed if wheat proteins, specifically "gliadins," are avoided in foods.

  10. History of inductively coupled plasma mass spectrometry-based immunoassays

    International Nuclear Information System (INIS)

    Giesen, Charlotte; Waentig, Larissa; Panne, Ulrich; Jakubowski, Norbert

    2012-01-01

    The analysis of biomolecules requires highly sensitive and selective detection methods capable of tolerating a complex, biological matrix. First applications of biomolecule detection by ICP-MS relied on the use of heteroelements as a label for quantification. However, the combination of immunoassays and ICP-MS facilitates multiparametric analyses through elemental tagging, and provides a powerful alternative to common bioanalytical methods. This approach extends the detection of biomarkers in clinical diagnosis, and has the potential to provide a deeper understanding of the investigated biological system. The results might lead to the detection of diseases at an early stage, or guide treatment plans. Immunoassays are well accepted and established for diagnostic purposes, albeit ICP-MS is scarcely applied for the detection of immune-based assays. However, the screening of biomarkers demands high throughput and multiplex/multiparametric techniques, considering the variety of analytes to be queried. Finally, quantitative information on the expression level of biomarkers is highly desirable to identify abnormalities in a given organism. Thus, it is the aim of this review to introduce the fundamentals, and to discuss the enormous strength of ICP-MS for the detection of different immunoassays on the basis of selected applications, with a special focus on LA‐ICP‐MS. - Highlights: ► We discuss the fundamentals of elemental tagging for ICP‐MS applications. ► We propose a definition for the expressions “label” and “tag”. ► We highlight LA‐ICP‐MS‐based heteroelement detection. ► We give an historic overview on ICP-MS and LA‐ICP‐MS-based immunoassays. ► In a personal outlook, we discuss future improvements realistically attainable.

  11. Ultrasensitive fluorescence immunoassay for detection of ochratoxin A using catalase-mediated fluorescence quenching of CdTe QDs

    Science.gov (United States)

    Huang, Xiaolin; Zhan, Shengnan; Xu, Hengyi; Meng, Xianwei; Xiong, Yonghua; Chen, Xiaoyuan

    2016-04-01

    Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to perform a dynamic linear detection of OTA ranging from 0.05 pg mL-1 to 10 pg mL-1. The half maximal inhibitory concentration was 0.53 pg mL-1 and the limit of detection was 0.05 pg mL-1. These values were approximately 283- and 300-folds lower than those of horseradish peroxidase (HRP)-based conventional ELISA, respectively. The reported method is accurate, highly reproducible, and specific against other mycotoxins in agricultural products as well. In summary, the developed fluorescence immunoassay based on H2O2-induced fluorescence quenching of CdTe QDs can be used for the rapid and highly sensitive detection of mycotoxins or haptens in food safety monitoring.Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to

  12. Development and application of radioimmunoassay and enzyme immunoassays in microbiological and immunological diagnosis. 3. Comparative studies for the detection of virus antibodies with passive hemagglutination test, radioimmunoassay and enzyme immunoassay, resp

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, H; Struy, H; Morenz, J [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Radioimmuno- and enzyme immunoassays (solid phase RIA and ELISA) developed by the authors for the determination of antibodies of adeno-2- and parainfluenza-1-viruses are described and the detection sensibility for antibodies is compared with that of the conventional passive hemagglutination test. The sensibility of the radioimmunoassay for the detection of IgG antibodies against adeno-2-viruses is nearly 10 times higher than that of the passive hemagglutination. RIA and ELISA show no essential differences in their detection sensibilities in the detection of IgG antibodies against parainfluenza-1-viruses.

  13. Evaluation of two automated enzyme-immunoassays for detection of thermophilic campylobacters in faecal samples from cattle and swine

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Nielsen, E.M.; Stryhn, H.

    1999-01-01

    We evaluated the performance of two enzyme-immunoassays (EIA) for the detection of naturally occurring, thermophilic Campylobacter spp. found in faecal samples from cattle (n = 21 and n = 26) and swine (n = 43) relative to the standard culture method, and also assuming that none of the tests...

  14. Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeriamonocytogenes in food

    NARCIS (Netherlands)

    Blazkova, M.; Koets, M.; Rauch, P.; Amerongen, van A.

    2009-01-01

    We present a new nucleic acid lateral flow immunoassay (NALFIA) for the assessment of listeria contamination. The detection procedure starts with enrichment of sample in Half Fraser broth (24 h). Following isolation of DNA, a duplex PCR is performed with two labelled primer sets, one generic and

  15. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  16. Detection of Aspergillus fumigatus mycotoxins: immunogen synthesis and immunoassay development.

    Science.gov (United States)

    Fox, M; Gray, G; Kavanagh, K; Lewis, C; Doyle, S

    2004-02-01

    Immunological detection of secreted low molecular weight toxins represents a potentially novel means of diagnosing infection by the fungus Aspergillus fumigatus. Two such metabolites, gliotoxin and helvolic acid, were selected and conjugated to thyroglobulin for antisera generation in rabbits. Gliotoxin was initially activated using N-[p-maleimidophenyl] isocyanate (PMPI) and subsequently conjugated to S-acetyl thioglycolic acid N-hydroxysuccinimide-activated thyroglobulin, whereas helvolic acid was activated with N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) in the presence of thyroglobulin prior to immunisation. To facilitate subsequent antisera evaluation, both toxins were similarly conjugated to bovine serum albumin (BSA). Matrix-Assisted Laser Desorption Ionisation-Time Of Flight (MALDI-TOF) mass spectrometry and SDS-PAGE analysis confirmed covalent attachment of toxins to BSA in the ratios of 15 and 2.4 mol per mol BSA for gliotoxin and helvolic acid, respectively. Resultant high titer antisera were capable of detecting both BSA-conjugated toxins (inhibitory concentration (IC)(50): 4-5 microg/ml). Free toxins were also detectable by competitive immunoassay, whereby 10 microg/ml free gliotoxin (30 microM) and helvolic acid (17 microM), respectively, inhibited antibody binding to cognate toxin-BSA previously immobilised on microwells. This work confirms that sensitive and specific antisera can be raised against fungal toxins and may have an application in diagnosing fungal infection.

  17. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    International Nuclear Information System (INIS)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro; Onodera, Takeshi; Toko, Kiyoshi

    2014-01-01

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  18. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Onodera, Takeshi [Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan); Toko, Kiyoshi, E-mail: toko@ed.kyushu-u.ac.jp [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan)

    2014-05-30

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  19. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Rui [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Xiong, Yonghua, E-mail: yhxiongchen@163.com [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China)

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H{sub 2}O{sub 2}) and H{sub 2}O{sub 2}-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H{sub 2}O{sub 2} and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H{sub 2}O{sub 2}, as well as the incubation time between H{sub 2}O{sub 2} and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10{sup 2} CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10{sup 3} CFU/mL to 1.18 × 10{sup 6} CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H{sub 2}O{sub 2}-sensitive QDs. • The activity of CAT to H{sub 2}O{sub 2} is 1000 folds higher than that of the HRP

  20. Status of immunoassay as an analytical tool in environmental investigations

    International Nuclear Information System (INIS)

    Van Emon, J.M.

    2000-01-01

    Immunoassay methods were initially applied in clinical situations where their sensitivity and selectivity were utilized for diagnostic purposes. In the 1970s, pesticide chemists realized the potential benefits of immunoassay methods for compounds difficult to analyze by gas chromatography. This transition of the technology has extended to the analysis of soil, water, food and other matrices of environmental and human exposure significance particularly for compounds difficult to analyze by chromatographic methods. The utility of radioimmunoassays and enzyme immunoassays for environmental investigations was recognized in the 1980s by the U.S. Environmental Protection Agency (U.S. EPA) with the initiation of an immunoassay development programme. The U.S. Department of Agriculture (USDA) and the U.S. Food and Drug Administration (PDA) have investigated immunoassays for the detection of residues in food both from an inspection and a contamination prevention perspective. Environmental immunoassays are providing rapid screening information as well as quantitative information to fulfill rigorous data quality objectives for monitoring programmes

  1. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  2. Electrochemical Immunoassay Using Open Circuit Potential Detection Labeled by Platinum Nanoparticles

    Directory of Open Access Journals (Sweden)

    Kanokwan Charoenkitamorn

    2018-02-01

    Full Text Available In this work, a simple electrochemical immunoassay based on platinum nanoparticles (PtNPs using open circuit potential (OCP detection was developed. The detection of human chorionic gonadotropin hormone (hCG as a model analyte, was demonstrated by direct electrical detection of PtNPs in hydrazine solution using OCP measurement without any application of either potential or current to the system. Disposable screen-printed carbon electrodes (SPCEs were utilized for the development of our immunosensor, which required a sample volume as small as 2 μL. After preparation of a sandwich-type immunosystem, hydrazine solution was dropped on the electrode’s surface, which was followed immediately by electrical detection using OCP. The change of the OCP signal originated from electrocatalytic oxidation of the hydrazine on PtNPs. Under the optimal conditions of a pH of 6.0 and a hydrazine concentration of 1 mM, a detection limit of 0.28 ng mL−1 and a linearity of 0–10 ng mL−1 were obtained. The PtNP-based OCP method is a simpler electrochemical detection procedure than those obtained from other electrochemical methods and has an acceptable sensitivity and reproducibility. The simplicity of the detection procedure and the cost-effectiveness of the disposable SPCE illustrate the attractive benefits of this sensor. Moreover, it could be applied to a simplified and miniaturized diagnostic system with minimal user manipulation.

  3. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.

    Science.gov (United States)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H 2 O 2 ) and H 2 O 2 -sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H 2 O 2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H 2 O 2 , as well as the incubation time between H 2 O 2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10 2  CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10 3  CFU/mL to 1.18 × 10 6  CFU/mL were in the range of 65.88%-105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on ...

  5. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    OpenAIRE

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of th...

  6. Photoelectrochemical detection of enzymatically generated CdS nanoparticles: Application to development of immunoassay.

    Science.gov (United States)

    Barroso, Javier; Saa, Laura; Grinyte, Ruta; Pavlov, Valeri

    2016-03-15

    We report an innovative photoelectrochemical process (PEC) based on graphite electrode modified with electroactive polyvinylpyridine bearing osmium complex (Os-PVP). The system relies on the in situ enzymatic generation of CdS quantum dots (QDs). Alkaline phosphatase (ALP) catalyzes the hydrolisis of sodium thiophosphate (TP) to hydrogen sulfide (H2S) which in the presence Cd(2+) ions yields CdS semiconductor nanoparticles (SNPs). Irradiation of SNPs with the standard laboratory UV-illuminator (wavelength of 365 nm) results in photooxidation of 1-thioglycerol (TG) mediated by Os-PVP complex on the surface of graphite electrode at applied potential of 0.31 V vs. Ag/AgCl. A novel immunoassay based on specific enzyme linked immunosorbent assay (ELISA) combined with the PEC methodology was developed. Having selected the affinity interaction between bovine serum albumine (BSA) with anti-BSA antibody (AB) as a model system, we built the PEC immunoassay for AB. The new assay displays a linear range up to 20 ngmL(-1) and a detection limit (DL) of 2 ngmL(-1) (S/N=3) which is lower 5 times that of the traditional chromogenic ELISA test employing p-nitro-phenyl phosphate (pNPP). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Ultrasensitive and accelerated detection of ciguatoxin by capillary electrophoresis via on-line sandwich immunoassay with rotating magnetic field and nanoparticles signal enhancement.

    Science.gov (United States)

    Zhang, Zhaoxiang; Zhang, Chaoying; Luan, Wenxiu; Li, Xiufeng; Liu, Ying; Luo, Xiliang

    2015-08-12

    A sensitive and rapid on-line immunoassay for the determination of ciguatoxin CTX3C was developed based on a capillary mixing system, which was integrated with capillary electrophoresis (CE) separation and electrochemical (EC) detection. In the sandwich immunoassay system, anti-CTX3C-functionalized magnetic nanoparticles were used as immunosensing probes, and horseradish peroxidase (HRP) and anti-CTX3C antibody were bound onto the surface of gold nanoparticles (AuNPs) and used as recognition elements. Online formation of immunocomplex was realized in capillary inlet end with an external rotating magnetic field. Compared with classical HPLC-MS and ELISA, the assay adopting AuNPs as multienzyme carriers and online sandwich immunoassay format with rotating magnetic field exhibited higher sensitivity and shorter assay time. The linear range of the assay for CTX3C was from 0.6 to 150 ng/L with a correlation coefficient of 0.9948 (n = 2), and the detection limit (S/N = 3) was 0.09 ng/L. The developed assay showed satisfying reproducibility and stability, and it was successfully applied for the quantification of CTX3C in fish samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Development and statistical assessment of a paper-based immunoassay for detection of tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Mazzu-Nascimento, Thiago [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil); Morbioli, Giorgio Gianini [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil); School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Milan, Luis Aparecido [Departamento de Estatística, Universidade Federal de São Carlos, São Carlos, SP (Brazil); Donofrio, Fabiana Cristina [Instituto de Ciências da Saúde, Universidade Federal de Mato Grosso, 78557-267, Sinop, MT (Brazil); Mestriner, Carlos Alberto [Wama Produtos para Laboratório Ltda, 13560-971, São Carlos, SP (Brazil); Carrilho, Emanuel, E-mail: emanuel@iqsc.usp.br [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil)

    2017-01-15

    Paper-based assays are an attractive low-cost option for clinical chemistry testing, due to characteristics such as short time of analysis, low consumption of samples and reagents, and high portability of assays. However, little attention has been given to the evaluation of the performance of these simple tests, which should include the use of a statistical approach to define the choice of best cut-off value for the test. The choice of the cut-off value impacts on the sensitivity and specificity of the bioassay. Here, we developed a paper-based immunoassay for the detection of the carcinoembryonic antigen (CEA) and performed a statistical assessment to establish the assay's cut-off value using the Youden's J index (68.28 A.U.), what allowed for a gain in sensibility (0.86) and specificity (1.0). We also discuss about the importance of defining a gray zone as a safety margin for test (±12% over the cut-off value), eliminating all false positives and false negatives outcomes and avoiding misleading results. The test accuracy was calculated as the area under the curve (AUC) of the receiver operating characteristic (ROC) curve, presenting a value of 0.97, what classifies this test as highly accurate. We propose here a low-cost method capable of detecting carcinoembryonic antigen (CEA) in human serum samples, highlighting the importance of statistical tools to evaluate a new low-cost diagnostic method. - Highlights: • A paper-based sandwich immunoassay protocol for detection of tumor markers. • A statistical approach to define cut-off values and measuring test's sensitivity, specificity and accuracy. • A simple way to create a gray zone, avoiding false positive and false negative outcomes.

  9. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Piccini, Matthew Ernest [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Cepheid, Sunnyvale, CA (United States); Schaff, Ulrich Y. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Stanker, Larry H. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Cheng, Luisa W. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Ravichandran, Easwaran [Univ. of Massachusetts, Dartmouth, MA (United States); Singh, Bal-Ram [Univ. of Massachusetts, Dartmouth, MA (United States); Sommer, Greg J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-01-01

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

  10. Immunoassay separation technique

    International Nuclear Information System (INIS)

    1977-01-01

    A method for effecting the immunoassay of a multiplicity of samples, each possibly containing an antigen or an antibody to be assayed, is discussed. Each sample is incubated with a solution containing a detectable antigen or antibody to form a multiplicity of mixtures, each mixture containing as components antigen-antibody, non-complexed antigen and non-complexed antibody. At least one of the components of the said mixture is separated by adsorption. There after, quantity of detectable antigen or antibody is detected in one of the non-adsorbed portions of the mixture. An improvement, compared to other techniques, is the continuous and sequential separation of at least one component, which is intended to be separated from each said multiplicity of mixtures

  11. A versatile SERS-based immunoassay for immunoglobulin detection using antigen-coated gold nanoparticles and malachite green-conjugated protein A/G

    Science.gov (United States)

    A surface enhanced Raman scattering (SERS) immunoassay for antibody detection in serum is described in the present work. The developed assay is conducted in solution and utilizes Au nanoparticles coated with the envelope (E) protein of West Nile Virus (WNV) as the SERS-active substrate and malachite...

  12. Molecularly Imprinted Polymer as an Antibody Substitution in Pseudo-immunoassays for Chemical Contaminants in Food and Environmental Samples.

    Science.gov (United States)

    Chen, Chaochao; Luo, Jiaxun; Li, Chenglong; Ma, Mingfang; Yu, Wenbo; Shen, Jianzhong; Wang, Zhanhui

    2018-03-21

    The chemical contaminants in food and the environment are quite harmful to food safety and human health. Rapid, accurate, and cheap detection can effectively control the potential risks derived from these chemical contaminants. Among all detection methods, the immunoassay based on the specific interaction of antibody-analyte is one of the most widely used techniques in the field. However, biological antibodies employed in the immunoassay usually cannot tolerate extreme conditions, resulting in an unstable state in both physical and chemical profiles. Molecularly imprinted polymers (MIPs) are a class of polymers with specific molecular recognition abilities, which are highly robust, showing excellent operational stability under a wide variety of conditions. Recently, MIPs have been used in biomimetic immunoassays for chemical contaminants as an antibody substitute in food and the environment. Here, we reviewed these applications of MIPs incorporated in different analytical platforms, such as enzyme-linked immunosorbent assay, fluorescent immunoassay, chemiluminescent immunoassay, electrochemical immunoassay, microfluidic paper-based immunoassay, and homogeneous immunoassay, and discussed current challenges and future trends in the use of MIPs in biomimetic immunoassays.

  13. A fast universal immobilization of immunoglobulin G at 4 °C for the development of array-based immunoassays.

    Directory of Open Access Journals (Sweden)

    Shu-Lin Guo

    Full Text Available To maintain the antibody activity and enhance performance of array-based immunoassays, protein G was used to allow a shorter duration of immunoglobulin G immobilization at 4 °C, with the antibody placed in the appropriate orientation. The multiplexed detection of six pain-related message molecules (PRMMs was used as examples for the development of array-based immunoassays: substance P, calcitonin gene-related peptide, nerve growth factor, brain-derived neurotrophic factor, tumor necrosis factor-α, and β-endorphin. Protein G- and non-protein G-coated slides were tested. Compared to non-protein G immunoassays, protein G shortened the antibody immobilization time at 4 °C from overnight to 2 hours. Only protein G-facilitated immunoassays succeeded in simultaneously detecting all six PRMMs with high specificity. Dose-response curves showed that the limits of detection of the protein G-multiplexed immunoassays for the PRMMs was approximately 164, 167, 120, 60, 80, and 92 pg/ml, respectively. Thus, protein G effectively shortens the duration of antibody immobilization at 4 °C, allowing the use of sensitive array-based immunoassays for the simultaneous detection of PRMMs.

  14. Electrochemical Sandwich Immunoassay for the Ultrasensitive Detection of Human MUC1 Cancer Biomarker

    Directory of Open Access Journals (Sweden)

    Zahra Taleat

    2013-01-01

    Full Text Available A new electrochemical sandwich immunoassay for the ultrasensitive detection of human MUC1 cancer biomarker using protein G-functionalized magnetic beads (MBs and graphite-based screen-printed electrodes (SPEs was developed. Magnetic beads were employed as the platforms for the immobilization and immunoreaction process. A pair of primary and secondary antibodies was used to capture the MUC1 protein. After labeling with a third antibody conjugated with horseradish peroxidase (HRP, the resulting conjugate was trapped at the surface of the graphite-based SPEs and MUC1 determination was carried out by differential pulse voltammetry (DPV at 0.4 V upon H2O2 addition using acetaminophen (APAP as the redox mediator. A linear relationship was obtained for the detection of human MUC1 over a range of 0–25 ppb with the lowest detection limit of 1.34 ppb when HRP was applied as a label. Preliminary experiments were performed using disposable electrochemical sensors in order to optimize some parameters (i.e., incubation times, concentrations, and blocking agent.

  15. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhanjun [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); College of Chemistry and Engineering, Yangzhou University, 88 South University Avenue, Yangzhou 225002 (China); Zong Chen [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Yan Feng, E-mail: yanfeng2007@sohu.com [Jiangsu Institute of Cancer Prevention and Cure, Nanjing 210009 (China)

    2011-11-07

    Highlights: {yields} A novel capillary immune microreactor was proposed for highly efficient flow-through chemiluminescent immunoassay. {yields} The microreactor was prepared by functionalizing capillary inner wall with streptavidin for capture of biotinylated antibody. {yields} The proposed immunoassay method showed wide dynamic range, good reproducibility, stability and practicality. {yields} The microreactor was low-cost and disposable, and possessed several advantages over the conventional immunoreactors. - Abstract: A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using {alpha}-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL{sup -1} and a low detection limit of 0.1 ng mL{sup -1}. The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay.

  16. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-02-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved by 39% compared to that of the Xenon flash lamp based unit, due to the LEDs narrower emission spectrum and longer pulse width. Key parameters of the LED system are discussed to further optimize the signal-to-noise ratio and signal-to-background, and hence the sensitivity of the instrument.

  17. Studies on direct and indirect electrochemical immunoassays

    OpenAIRE

    Buckley, Eileen

    1989-01-01

    Two approaches to electrochemical immunoassay are reported. The first approach was an indirect method, involving an electroactive, enzyme-catalysed, substrate to product reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical detection of an immunoglo...

  18. Highly sensitive immunoassay based on E. coli with autodisplayed Z-domain

    International Nuclear Information System (INIS)

    Jose, Joachim; Park, Min; Pyun, Jae-Chul

    2010-01-01

    The Z-domain of protein A has been known to bind specifically to the F c region of antibodies (IgGs). In this work, the Z-domain of protein A was expressed on the outer membrane of Escherichia coli by using 'Autodisplay' technology as a fusion protein of autotransport domain. The E. coli with autodisplayed Z-domain was applied to the sandwich-type immunoassay as a solid-support of detection-antibodies against a target analyte. For the feasibility demonstration of the E. coli based immunoassay, C-reactive protein (CRP) assay was carried out by using E. coli with autodisplayed Z-domain. The limit of detection (LOD) and binding capacity of the E. coli based immunoassay were estimated to be far more sensitive than the conventional ELISA. Such a far higher sensitivity of E. coli based immunoassay than conventional ELISA was explained by the orientation control of immobilized antibodies and the mobility of E. coli in assay matrix. From the test results of 45 rheumatoid arthritis (RA) patients' serum and 15 healthy samples, a cut-off value was established to have optimal sensitivity and selectivity values for RA. The CRP test result of each individual sample was compared with ELISA which is the reference method for RA diagnosis. From this work, the E. coli with Z-domain was proved to be feasible for the medical diagnosis based on sandwich-type immunoassay.

  19. Multiple signal amplified electrochemiluminescent immunoassay for brombuterol detection using gold nanoparticles and polyamidoamine dendrimers-silver nanoribbon

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Tiantian; Hu, Liuyi; Zhao, Kang; Deng, Anping, E-mail: denganping@suda.edu.cn; Li, Jianguo, E-mail: lijgsd@suda.edu.cn

    2016-11-16

    Electrochemiluminescent (ECL) immunosensor with multiple signal amplification was designed based on gold nanoparticles (AuNPs), polyamidoamine dendrimers (PAMAM) and silver-cysteine hybrid nanoribbon (SNR). Low toxic L-cysteine capped CdSe QDs was chosen as the ECL signal probe. To verify the proposed ultrasensitive ECL immunosensor for β-adrenergic agonists (β-AA), we detected Brombuterol (Brom) as a proof-of-principle analyte. Therein, AuNPs as the substrate can simplify the experiment process, accelerate the electron transfer rate, and carry more coating antigen (Ag-OVA) to enlarge ECL signal. On one hand, SNR on the surface of electrode can avoid the aggregation of AuNPs, and SNR-PAMAM-AuNPs also can be acted as a good accelerator for electron transfer. On the other hand, PAMAM (16 -NH{sub 2}) functionalized SNR (SNR-PAMAM) with numerous amino groups could be employed to bond abundant actived QDs to further amplify ECL signal. The new immunosensor can offer a simple, reliable, rapid, and selective detection for Brom, which have a dynamic range of 0.005–700 ng mL{sup −1} with a low detection limit at 1.5 pg mL{sup −1}. The proposed biosensor will extend the application of nanomaterials in ECL immunoassays and open a new road for the detection of Brom and other β-AA in the future. - Highlights: • A multiple signal amplification ECL immunosensor of eco-friendly CdSe QDs for brombuterol determination was developed. • Besides substrates, AuNPs and PAMAM-SNR were creatively used to accelerate the electron transport between electrode and QDs. • SNR-PAMAM with numerous amino groups also could be employed to bond abundant actived QDs to amplify ECL signal. • Competitive immunoassay was performed with ECL to detect small molecules of brombuterol. • It provided a method for detecting Brom and enlarged the usage of QDs, AuNPs and SNR-PAMAM in ECL biosensing.

  20. Multiple signal amplified electrochemiluminescent immunoassay for brombuterol detection using gold nanoparticles and polyamidoamine dendrimers-silver nanoribbon

    International Nuclear Information System (INIS)

    Dong, Tiantian; Hu, Liuyi; Zhao, Kang; Deng, Anping; Li, Jianguo

    2016-01-01

    Electrochemiluminescent (ECL) immunosensor with multiple signal amplification was designed based on gold nanoparticles (AuNPs), polyamidoamine dendrimers (PAMAM) and silver-cysteine hybrid nanoribbon (SNR). Low toxic L-cysteine capped CdSe QDs was chosen as the ECL signal probe. To verify the proposed ultrasensitive ECL immunosensor for β-adrenergic agonists (β-AA), we detected Brombuterol (Brom) as a proof-of-principle analyte. Therein, AuNPs as the substrate can simplify the experiment process, accelerate the electron transfer rate, and carry more coating antigen (Ag-OVA) to enlarge ECL signal. On one hand, SNR on the surface of electrode can avoid the aggregation of AuNPs, and SNR-PAMAM-AuNPs also can be acted as a good accelerator for electron transfer. On the other hand, PAMAM (16 -NH_2) functionalized SNR (SNR-PAMAM) with numerous amino groups could be employed to bond abundant actived QDs to further amplify ECL signal. The new immunosensor can offer a simple, reliable, rapid, and selective detection for Brom, which have a dynamic range of 0.005–700 ng mL"−"1 with a low detection limit at 1.5 pg mL"−"1. The proposed biosensor will extend the application of nanomaterials in ECL immunoassays and open a new road for the detection of Brom and other β-AA in the future. - Highlights: • A multiple signal amplification ECL immunosensor of eco-friendly CdSe QDs for brombuterol determination was developed. • Besides substrates, AuNPs and PAMAM-SNR were creatively used to accelerate the electron transport between electrode and QDs. • SNR-PAMAM with numerous amino groups also could be employed to bond abundant actived QDs to amplify ECL signal. • Competitive immunoassay was performed with ECL to detect small molecules of brombuterol. • It provided a method for detecting Brom and enlarged the usage of QDs, AuNPs and SNR-PAMAM in ECL biosensing.

  1. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  2. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  3. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B_1 detection in cereal

    International Nuclear Information System (INIS)

    Shu, Mei; Xu, Yang; Liu, Xing; Li, Yanping; He, Qinghua; Tu, Zhui; Fu, Jinheng; Gee, Shirley J.; Hammock, Bruce D.

    2016-01-01

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB_1 was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB_1 were 2.69 and 0.35 ng mL"−"1, respectively, with a linear range of 0.93–7.73 ng mL"−"1. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL"−"1, and the IC_5_0 was 0.89 ± 0.09 ng mL"−"1 with a linear range of 0.29–2.68 ng mL"−"1. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB_1 contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  4. Fieldable, real-time enzyme immunoassay kits for drugs on surfaces

    Science.gov (United States)

    Chiappini, Michele W.; Wendel, Gregory J.; Duquette, Peter H.; Hamilton, Martha J.; Chudzik, Stephen J.; Chappa, Ralph A.

    1994-03-01

    Immunoassays (e.g., RIA, EIA) have been demonstrated to be useful for rapid, convenient detection and semiquantitative analysis of drugs. Thermedics Detection, Inc. manufactures a rapid, sensitive, self-contained, disposable, EIA device, developed by Bio-Metric Systems, Inc., designed to allow untrained personnel to perform in field situations. This format has been developed for drugs in biological fluids and on surfaces. The analyte in the test sample competes with an enzyme-analyte conjugate for a limited number of immobilized antibody sites. The AccuPRESS Test format can detect analytes at 10 ppb in biological fluids, water, and soil, and on surfaces, such as suitcases, vehicles, tables and hands, with positive results indicated by clearly visible color development within 5 minutes. This format is designed to have all dry components and to have an ambient shelf life of greater than one year. The format is available for cocaine and opiate derivatives, including heroin, and is readily adaptable for use with numerous other drugs, explosives, and environmental pollutants.

  5. Multi-sample immunoassay inside optical fiber capillary enabled by evanescent wave detection

    Directory of Open Access Journals (Sweden)

    Chun-Wei Wang

    2016-03-01

    Full Text Available A novel evanescent wave-based (EW microfluidic capillary fiber-optic biosensor (MCFOB has been developed using capillaries as a transducer embedded in a multichannel device to enhance the collection efficiency of the fluorescence signal. The capillary serves dual roles as a waveguide and a container, enabling more straightforward, consistent, and compact biosensor packaging compared to conventional optical fiber biosensors and microfluidic systems. In order to detect multiple samples in one device, the biosensor incorporates a polydimethysiloxane (PDMS multi-channel device, which also serves as cladding for the biosensor. In addition, this biosensor only consumes 10 μl of a sample and does not require hydrofluoric acid etching in the fabrication process. The orientation for signal collection is optimized by comparing the lateral and normal signal directions for detected glyceraldehyde 3-phosphate dehydrogenase (GAPDH. C-reactive protein (CRP is used to validate the MCFOB, and the limit of detection (LOD for CRP in the MCFOB is 1.94 ng/ml (74 pM. Moreover, the real-time measurement is demonstrated to verify that the evanescent wave is the only exciting light source in the MCFOB, which gives the potential for real-time measurement applications. Keywords: C-reactive protein, Capillary, Fiber-optic, Microfluidic, Evanescent wave, Immunoassay

  6. Immunoassay for Capsular Antigen of Bacillus anthracis Enables Rapid Diagnosis in a Rabbit Model of Inhalational Anthrax.

    Directory of Open Access Journals (Sweden)

    Marcellene A Gates-Hollingsworth

    Full Text Available Inhalational anthrax is a serious biothreat. Effective antibiotic treatment of inhalational anthrax requires early diagnosis; the further the disease has progressed, the less the likelihood for cure. Current means for diagnosis such as blood culture require several days to a result and require advanced laboratory infrastructure. An alternative approach to diagnosis is detection of a Bacillus anthracis antigen that is shed into blood and can be detected by rapid immunoassay. The goal of the study was to evaluate detection of poly-γ-D-glutamic acid (PGA, the capsular antigen of B. anthracis, as a biomarker surrogate for blood culture in a rabbit model of inhalational anthrax. The mean time to a positive blood culture was 26 ± 5.7 h (mean ± standard deviation, whereas the mean time to a positive ELISA was 22 ± 4.2 h; P = 0.005 in comparison with blood culture. A lateral flow immunoassay was constructed for detection of PGA in plasma at concentrations of less than 1 ng PGA/ml. Use of the lateral flow immunoassay for detection of PGA in the rabbit model found that antigen was detected somewhat earlier than the earliest time point at which the blood culture became positive. The low cost, ease of use, and rapid time to result of the lateral flow immunoassay format make an immunoassay for PGA a viable surrogate for blood culture for detection of infection in individuals who have a likelihood of exposure to B. anthracis.

  7. Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite

    Directory of Open Access Journals (Sweden)

    Zhao Y

    2017-07-01

    Full Text Available Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE with well clinical relevance to house dust mite (HDM are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE 

  8. Comparison of conventional culture methods and two commercial enzyme immunoassays for detection of Salmonella in porcine fecal samples and cecal contents

    DEFF Research Database (Denmark)

    Wegener, Henrik Caspar; Baggesen, Dorte Lau

    1997-01-01

    Two commercial enzyme immunoassays, designated EIA-1 and EIA-2, for the detection of salmonella in feces and cecal contents were compared to conventional culture methods. Out of 362 cecal content samples, 35 were positive by EIA-1 and 30 were positive by EIA-2 and conventional methods. Out of 189...

  9. [Automated analyzer of enzyme immunoassay].

    Science.gov (United States)

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  10. Evaluation of envelope glycoprotein E(rns) of an atypical bovine pestivirus as antigen in a microsphere immunoassay for the detection of antibodies against bovine viral diarrhea virus 1 and atypical bovine pestivirus.

    Science.gov (United States)

    Vijayaraghavan, Balaje; Xia, Hongyan; Harimoorthy, Rajiv; Liu, Lihong; Belák, Sándor

    2012-11-01

    Atypical bovine pestiviruses are related antigenically and phylogenetically to bovine viral diarrhea viruses (BVDV-1 and BVDV-2), and may cause the same clinical manifestations in animals. Glycoprotein E(rns) of an atypical bovine pestivirus Th/04_KhonKaen was produced in a baculovirus expression system and was purified by affinity chromatography. The recombinant E(rns) protein was used as an antigen in a microsphere immunoassay for the detection of antibodies against BVDV-1 and atypical bovine pestivirus. The diagnostic performance of the new method was evaluated by testing a total of 596 serum samples, and the assay was compared with enzyme-linked immunosorbent assay (ELISA). Based on the negative/positive cut-off median fluorescence intensity (MFI) value of 2800, the microsphere immunoassay had a sensitivity of 100% and specificity of 100% compared to ELISA. The immunoassay was able to detect antibodies against both BVDV-1 and the atypical pestivirus. This novel microsphere immunoassay has the potential to be multiplexed for simultaneous detection of antibodies against different bovine pathogens in a high-throughput and economical way. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Indirect competitive immunoassay for the detection of fungicide Thiabendazole in whole orange samples by Surface Plasmon Resonance.

    Science.gov (United States)

    Estevez, M-Carmen; Belenguer, Jose; Gomez-Montes, Silvia; Miralles, Javier; Escuela, Alfonso M; Montoya, Angel; Lechuga, Laura M

    2012-12-07

    A highly sensitive and specific SPR-based competitive immunoassay for the detection of Thiabendazole (TBZ) has been developed. An indirect format where a TBZ-protein conjugate is immobilized onto gold surfaces has been selected. Under the optimal conditions, a LOD of 0.67 nM (0.13 μg L(-1)) and an IC(50) of 3.2 nM (0.64 μg L(-1)) have been achieved which are comparable to the values obtained by conventional ELISA. Analysis of real samples has been attempted by first evaluating the influence of complex matrix samples coming from whole oranges and secondly measuring samples containing TBZ previously evaluated by chromatographic methods. A methanolic extraction procedure followed by a simple dilution in assay buffer has proven to be sufficient to measure orange samples using the developed immunoassay with an excellent recovery percentage. The sensitivity and the feasibility of measuring whole orange samples demonstrate the effectiveness and robustness of the SPR biosensor, which can be useful for the determination of TBZ in food at concentrations below the Maximum Residue Levels (MRLs) established by the European legislation.

  12. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    OpenAIRE

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by fac...

  13. A sensitive chemiluminescent immunoassay to detect Chromotrope FB (Chr FB) in foods.

    Science.gov (United States)

    Xu, Kun; Long, Hao; Xing, Rongge; Yin, Yongmei; Eremin, Sergei A; Meng, Meng; Xi, Rimo

    2017-03-01

    Chromotrope FB (Chr FB) is a synthetic azo dye permitted for use in foods and medicines. An acceptable daily intake (ADI) of Chr FB was 0-0.5mg/kg in China. In this study, we synthesized a Chr FB hapten with an amino group to prepare its artificial immunogen. Polyclonal antibodies obtained from New Zealand rabbits were applied to develop an indirect competitive chemiluminescent immunoassay (icCLIA) to detect Chr FB in foods. A horseradish peroxidase (HRP)-luminol-H 2 O 2 system was used to yield CL signal with p-iodophenol as an enhancement reagent. The method showed good specificity towards Chr FB and could detect as low as 0.02ngmL -1 Chr FB in buffer, 0.07ngg -1 in yoghurt candy, 0.07ngg -1 in vitamin drink and 0.13ngg -1 in bread. Compared with HPLC method, the proposed method is more sensitive by two orders of magnitude. The accuracy and precision of this method are acceptable and comparable with HPLC method. Therefore, the proposed method could be used for rapid screening of Chr FB in the mentioned foodstuffs. Copyright © 2016. Published by Elsevier B.V.

  14. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  15. Direct tissue blot immunoassay for detection of Xylella fastidiosa in olive trees

    Directory of Open Access Journals (Sweden)

    Khaled DJELOUAH

    2015-01-01

    Full Text Available A direct tissue blot immunoassay (DTBIA technique has been compared with ELISA and PCR for detection of Xylella fastidiosa in olive trees from Apulia (southern Italy. Fresh cross-sections of young twigs and leaf petioles were printed onto nitrocellulose membranes and analyzed in the laboratory. Analyses of a first group of 61 samples gave similar efficiency for the three diagnostic techniques for detection the bacterium (24 positive and 36 negative samples, except for a single sample which was positive only with DTBIA and PCR. Similar results were obtained by separately analyzing suckers and twigs collected from different sectors of tree canopies of a second group of 20 olive trees (ten symptomatic and ten symptomless. In this second test the three diagnostic techniques confirmed the irregular distribution of the bacterium in the tree canopies and erratic detectability of the pathogen in the young suckers. It is therefore necessary to analyse composite samples per tree which should be prepared with twigs collected from different sides of the canopy. The efficiency comparable to ELISA and PCR, combined with the advantages of easier handling, speed and cost, make DTBIA a valid alternative to ELISA in large-scale surveys for occurrence of X. fastidiosa. Moreover, the printing of membranes directly in the field prevents infections spreading to Xylella-free areas, through movement of plant material with pathogen vectors for laboratory testing.

  16. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    DEFF Research Database (Denmark)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter

    2017-01-01

    of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared...... to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research highsensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time...

  17. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B{sub 1} detection in cereal

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Mei [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Xu, Yang, E-mail: xuyang@ncu.edu.cn [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Liu, Xing [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); College of Food Science and Technology, Hainan University, No. 58 Renmin Avenue, Haikou 570228 (China); Li, Yanping; He, Qinghua [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Tu, Zhui [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Fu, Jinheng [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Gee, Shirley J.; Hammock, Bruce D. [Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, CA 95616 (United States)

    2016-06-14

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB{sub 1} was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB{sub 1} were 2.69 and 0.35 ng mL{sup −1}, respectively, with a linear range of 0.93–7.73 ng mL{sup −1}. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL{sup −1}, and the IC{sub 50} was 0.89 ± 0.09 ng mL{sup −1} with a linear range of 0.29–2.68 ng mL{sup −1}. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB{sub 1} contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  18. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    International Nuclear Information System (INIS)

    Hervas, Miriam; Lopez, Miguel Angel; Escarpa, Alberto

    2009-01-01

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 μg L -1 and EC 50 0.079 μg L -1 were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  19. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: an anticipated analytical tool for food safety.

    Science.gov (United States)

    Hervás, Miriam; López, Miguel Angel; Escarpa, Alberto

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 microg L(-1) and EC(50) 0.079 microg L(-1) were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  20. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    Energy Technology Data Exchange (ETDEWEB)

    Hervas, Miriam; Lopez, Miguel Angel [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain); Escarpa, Alberto, E-mail: alberto.escarpa@uah.es [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain)

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 {mu}g L{sup -1} and EC{sub 50} 0.079 {mu}g L{sup -1} were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  1. Femtomolar detection of 2,4-dichlorophenoxyacetic acid herbicides via competitive immunoassays using microfluidic based carbon nanotube liquid gated transistor.

    Science.gov (United States)

    Wijaya, I Putu Mahendra; Nie, Tey Ju; Gandhi, Sonu; Boro, Robin; Palaniappan, Alagappan; Hau, Goh Wei; Rodriguez, Isabel; Suri, C Raman; Mhaisalkar, Subodh G

    2010-03-07

    Monitoring of environmental pollutants has become increasingly important due to concern over potential health and environmental impact inflicted by these chemicals. In this contribution, we focus on the development of an all-plastic biosensor comprising laminated single-walled carbon nanotubes as the active element and its conductance modulation in a liquid-gated field effect transistor, as the principle of transduction, for the detection of 2,4-dicholorophenoxy acetic acid (2,4-D) herbicide. The reported biosensor is capable of performing real-time label-free detection of analytes in liquid environment. This biosensor which relies on immunoassay principle for specificity is able to detect down to 500 fM levels of 2,4-D in soil samples.

  2. Specificity of immunoassays. Pt. 2

    International Nuclear Information System (INIS)

    Pratt, J.J.; Woldring, M.G.; Boonman, R.; Kittikool, J.

    1979-01-01

    Practical aspects of the measurement of the specificity of immunoassay are reviewed. Antibody heterogeneity in an antiserum makes a pragmatic rather than a theoretical approach necessary. A new method for the measurement of immunoassay specificity is described. This method is based on the errors caused by the cross-reacting antigens and is directly relevant to the validity of results obtained by immunoassay methods. The effect of selectively blocking the least specific antibodies in antisera raised against steroid haptens is tested. The practical consequences of these considerations are tested using steroid radioimmunoassay and enzyme-immunoassay. (orig.) [de

  3. Multicentric Evaluation of New Commercial Enzyme Immunoassays for the Detection of Immunoglobulin M and Total Antibodies against Hepatitis A Virus▿

    Science.gov (United States)

    Arcangeletti, M. C.; Dussaix, E.; Ferraglia, F.; Roque-Afonso, A. M.; Graube, A.; Chezzi, C.

    2011-01-01

    A multicentric clinical study was conducted on representative sera from 1,738 European and U.S. subjects for the evaluation of new anti-hepatitis A virus enzyme immunoassays from Bio-Rad Laboratories. Comparison with reference DiaSorin S.p.A. tests confirmed the good performance of Bio-Rad assays (99.85% and 99.47% overall agreement in detecting total antibodies and IgM, respectively). PMID:21653739

  4. An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen

    Directory of Open Access Journals (Sweden)

    Jacqueline M. Barnett

    2014-07-01

    Full Text Available We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM to quantify paramagnetic particles (PMPs in immunochromatographic (lateral flow assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format.

  5. Self-paired monoclonal antibody lateral flow immunoassay strip for rapid detection of Acidovorax avenae subsp. citrulli.

    Science.gov (United States)

    Zeng, Haijuan; Guo, Wenbo; Liang, Beibei; Li, Jianwu; Zhai, Xuzhao; Song, Chunmei; Zhao, Wenjun; Fan, Enguo; Liu, Qing

    2016-09-01

    We screened a highly specific monoclonal antibody (McAb), named 6D, against Acidovorax avenae subsp. citrulli (Aac). Single McAb 6D was used as both nanogold-labeled antibody and test antibody to develop a single self-paired colloidal gold immunochromatographic test strip (Sa-GICS). The detection limit achieved using the Sa-GICS approach was 10(5) CFU/mL, with a result that can be observed by the naked eye within 10 min. Moreover, Sa-GICS can detect eight strains of Aac and display no cross-reactions with other pathogenic plant microorganisms. Artificial contamination experiments demonstrated that Sa-GICS would not be affected by impurities in the leaves or stems of the plants and were consistent with the PCR results. This is the first report on the development of a colloidal gold immunoassay strip with self-paired single McAb for the rapid detection of Aac. Graphical Abstract Schematic representation of the test strip.

  6. Simple patterned nanofiber scaffolds and its enhanced performance in immunoassay.

    Directory of Open Access Journals (Sweden)

    Jing Wang

    Full Text Available Cancer has become the leading cause of death worldwide; early diagnosis and treatment of cancers is critical for the survival of the patients. The concentration of cancer markers in easy-to-access biological fluids can provide great assistance in screening for occult primary cancers, distinguishing malignant from benign findings, determining prognosis and prediction for cancer patients. The multiplex detection technology of a panel of cancer markers can greatly increase the accuracy of disease diagnosis. Herein, we briefly fabricate a high-throughput micro-immunoassay based on the electrospun polystyrene (PS substrates to improve detection sensitivity. The immunoassay was evaluated by analyzing three different cancer biomarkers (AFP, CEA, VEGF. For AFP, CEA, VEGF immunofluorescence assay, the LOD of assay conducted on electrospun PS substrates before or after plasma and the conventional PS substrates were 0.42, 0.10, 1.12 ng/mL, 0.57, 0.09, 1.24 ng/mL, and 159.75, 26.19, 385.59 pg/mL, respectively (P < 0.05. Due to the high porosity and large surface area-to-volume ratio which is the foremost merit of nanostructures, and the plasma treatment which make the hydrophobic PS nanofibers hydropholic, the nanofibers substrates showed sufficient retention of immunoassay functionality and high potential for capture molecules immobilization. Consequently, the immunofluorescence assay conducted on electrospun PS substrates could significantly enhance the sensitivity and limits of detection.

  7. Dual-Mode SERS-Fluorescence Immunoassay Using Graphene Quantum Dot Labeling on One-Dimensional Aligned Magnetoplasmonic Nanoparticles.

    Science.gov (United States)

    Zou, Fengming; Zhou, Hongjian; Tan, Tran Van; Kim, Jeonghyo; Koh, Kwangnak; Lee, Jaebeom

    2015-06-10

    A novel dual-mode immunoassay based on surface-enhanced Raman scattering (SERS) and fluorescence was designed using graphene quantum dot (GQD) labels to detect a tuberculosis (TB) antigen, CFP-10, via a newly developed sensing platform of linearly aligned magnetoplasmonic (MagPlas) nanoparticles (NPs). The GQDs were excellent bilabeling materials for simultaneous Raman scattering and photoluminescence (PL). The one-dimensional (1D) alignment of MagPlas NPs simplified the immunoassay process and enabled fast, enhanced signal transduction. With a sandwich-type immunoassay using dual-mode nanoprobes, both SERS signals and fluorescence images were recognized in a highly sensitive and selective manner with a detection limit of 0.0511 pg mL(-1).

  8. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    Science.gov (United States)

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Ultrasensitive colorimetric immunoassay for hCG detection based on dual catalysis of Au@Pt core-shell nanoparticle functionalized by horseradish peroxidase

    Science.gov (United States)

    Wang, Weiguo; Zou, Yake; Yan, Jinwu; Liu, Jing; Chen, Huixiong; Li, Shan; Zhang, Lei

    2018-03-01

    In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8 nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4-12.8 IU L- 1 with a low limit of detection (LOD) of 0.1 IU L- 1 compared with the LODs of 0.8 IU L- 1 for BA-ELISA and of 2.0 IU L- 1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection.

  10. Aequorin fusion proteins as bioluminescent tracers for competitive immunoassays

    Science.gov (United States)

    Mirasoli, Mara; Michelini, Elisa; Deo, Sapna K.; Dikici, Emre; Roda, Aldo; Daunert, Sylvia

    2004-06-01

    The use of bio- and chemiluminescence for the development of quantitative binding assays offers undoubted advantages over other detection systems, such as spectrophotometry, fluorescence, or radioactivity. Indeed, bio- and chemiluminescence detection provides similar, or even better, sensitivity and detectability than radioisotopes, while avoiding the problems of health hazards, waste disposal, and instability associated with the use of radioisotopes. Among bioluminescent labels, the calcium-activated photoprotein aequorin, originally isolated from Aequorea victoria and today available as a recombinant product, is characterized by very high detectability, down to attomole levels. It has been used as a bioluminescent label for developing a variety of highly sensitive immunoassays, using various analyte-aequorin conjugation strategies. When the analyte is a protein or a peptide, genetic engineering techniques can be used to produce protein fusions where the analyte is in-frame fused with aequorin, thus producing homogeneous one-to-one conjugation products, available in virtually unlimited amount. Various assays were developed using this strategy: a short review of the most interesting applications is presented, as well as the cloning, purification and initial characterization of an endothelin-1-aequorin conjugate suitable for developing a competitive immunoassay for endothelin-1, a potent vasoconstrictor peptide, involved in hypertension.

  11. Cellphone-based detection platform for rbST biomarker analysis in milk extracts using a microsphere fluorescence immunoassay.

    Science.gov (United States)

    Ludwig, Susann K J; Zhu, Hongying; Phillips, Stephen; Shiledar, Ashutosh; Feng, Steve; Tseng, Derek; van Ginkel, Leendert A; Nielen, Michel W F; Ozcan, Aydogan

    2014-11-01

    Current contaminant and residue monitoring throughout the food chain is based on sampling, transport, administration, and analysis in specialized control laboratories. This is a highly inefficient and costly process since typically more than 99% of the samples are found to be compliant. On-site simplified prescreening may provide a scenario in which only samples that are suspect are transported and further processed. Such a prescreening can be performed using a small attachment on a cellphone. To this end, a cellphone-based imaging platform for a microsphere fluorescence immunoassay that detects the presence of anti-recombinant bovine somatotropin (rbST) antibodies in milk extracts was developed. RbST administration to cows increases their milk production, but is illegal in the EU and a public health concern in the USA. The cellphone monitors the presence of anti-rbST antibodies (rbST biomarker), which are endogenously produced upon administration of rbST and excreted in milk. The rbST biomarker present in milk extracts was captured by rbST covalently coupled to paramagnetic microspheres and labeled by quantum dot (QD)-coupled detection antibodies. The emitted fluorescence light from these captured QDs was then imaged using the cellphone camera. Additionally, a dark-field image was taken in which all microspheres present were visible. The fluorescence and dark-field microimages were analyzed using a custom-developed Android application running on the same cellphone. With this setup, the microsphere fluorescence immunoassay and cellphone-based detection were successfully applied to milk sample extracts from rbST-treated and untreated cows. An 80% true-positive rate and 95% true-negative rate were achieved using this setup. Next, the cellphone-based detection platform was benchmarked against a newly developed planar imaging array alternative and found to be equally performing versus the much more sophisticated alternative. Using cellphone-based on-site analysis in

  12. Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection

    International Nuclear Information System (INIS)

    Ma Caiyun; Jiang Li; Ge Gaoxia; Zhang Xiaojie

    2005-01-01

    Electrochemiluminescene immunoassay (ECLIA) and enzyme-linked immunosorbent (ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA. The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values, 4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively. The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L. Only in 3 samples, the results measured by ECLIA and ELISA were different (ECLIA: positive; ELISA: negative) among 165 samples. It is concluded that the met hod of ECLIA is more efficient than ELISA for detection of HBsAb in serum. (authors)

  13. Description of a nanobody-based competitive immunoassay to detect tsetse fly exposure.

    Directory of Open Access Journals (Sweden)

    Guy Caljon

    2015-02-01

    Full Text Available Tsetse flies are the main vectors of human and animal African trypanosomes. The Tsal proteins in tsetse fly saliva were previously identified as suitable biomarkers of bite exposure. A new competitive assay was conceived based on nanobody (Nb technology to ameliorate the detection of anti-Tsal antibodies in mammalian hosts.A camelid-derived Nb library was generated against the Glossina morsitans morsitans sialome and exploited to select Tsal specific Nbs. One of the three identified Nb families (family III, TsalNb-05 and TsalNb-11 was found suitable for anti-Tsal antibody detection in a competitive ELISA format. The competitive ELISA was able to detect exposure to a broad range of tsetse species (G. morsitans morsitans, G. pallidipes, G. palpalis gambiensis and G. fuscipes and did not cross-react with the other hematophagous insects (Stomoxys calcitrans and Tabanus yao. Using a collection of plasmas from tsetse-exposed pigs, the new test characteristics were compared with those of the previously described G. m. moristans and rTsal1 indirect ELISAs, revealing equally good specificities (> 95% and positive predictive values (> 98% but higher negative predictive values and hence increased sensitivity (> 95% and accuracy (> 95%.We have developed a highly accurate Nb-based competitive immunoassay to detect specific anti-Tsal antibodies induced by various tsetse fly species in a range of hosts. We propose that this competitive assay provides a simple serological indicator of tsetse fly presence without the requirement of test adaptation to the vertebrate host species. In addition, the use of monoclonal Nbs for antibody detection is innovative and could be applied to other tsetse fly salivary biomarkers in order to achieve a multi-target immunoprofiling of hosts. In addition, this approach could be broadened to other pathogenic organisms for which accurate serological diagnosis remains a bottleneck.

  14. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  15. Monoclonal antibody-based immunoassays.

    Science.gov (United States)

    Appleby, P; Reischl, U

    1998-01-01

    An immunoassay may be defined as an assay that employs an immunological reagent, usually an antibody, to confer specificity for the ligand being measured. As a corollary to this, the discovery, and subsequent development, of monoclonal antibodies (MAbs) has greatly expanded the application and use of immunoassays. Polyclonal reagents, with their associated problems of specificity and quality control, have now been largely replaced by readily available MAbs of potential immortality and well-defined specificity and affinity. This has resulted, in the last two decades, in a great expansion in the range of immunoassays available and also a significant improvement in their reproducibility and reliability.

  16. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Micromotor-based lab-on-chip immunoassays

    Science.gov (United States)

    García, Miguel; Orozco, Jahir; Guix, Maria; Gao, Wei; Sattayasamitsathit, Sirilak; Escarpa, Alberto; Merkoçi, Arben; Wang, Joseph

    2013-01-01

    Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic polymer/Ni/Pt microtube engine, containing carboxy moieties on its mixed poly(3,4-ethylenedioxythiophene) (PEDOT)/COOH-PEDOT polymeric outermost layer, is further functionalized with the antibody receptor to selectively recognize and capture the target protein. The new motor-based microchip immunoassay operations are carried out without any bulk fluid flow, replacing the common washing steps in antibody-based protein bioassays with the active transport of the captured protein throughout the different reservoirs, where each step of the immunoassay takes place. A first microchip format involving an `on-the-fly' double-antibody sandwich assay (DASA) is used for demonstrating the selective capture of the target protein, in the presence of excess of non-target proteins. A secondary antibody tagged with a polymeric-sphere tracer allows the direct visualization of the binding events. In a second approach the immuno-nanomotor captures and transports the microsphere-tagged antigen through a microchannel network. An anti-protein-A modified microengine is finally used to demonstrate the selective capture, transport and convenient label-free optical detection of a Staphylococcus aureus target bacteria (containing proteinA in its cell wall) in the presence of a large excess of non-target (Saccharomyces cerevisiae) cells. The resulting nanomotor-based microchip immunoassay offers considerable potential for diverse applications in clinical diagnostics, environmental and security monitoring fields.Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic

  18. Label-Free Electrochemical Immunoassay for C-Reactive Protein

    Directory of Open Access Journals (Sweden)

    Madasamy Thangamuthu

    2018-03-01

    Full Text Available C-reactive protein (CRP is one of the most expressed proteins in blood during acute phase inflammation, and its minute level increase has also been recognized for the clinical diagnosis of cardio vascular diseases. Unfortunately, the available commercial immunoassays are labour intensive, require large sample volumes, and have practical limitations, such as low stability and high production costs. Hence, we have developed a simple, cost effective, and label-free electrochemical immunoassay for the measurement of CRP in a drop of serum sample using an immunosensor strip made up of a screen printed carbon electrode (SPE modified with anti-CRP functionalized gold nanoparticles (AuNPs. The measurement relies on the decrease of the oxidation current of the redox indicator Fe3+/Fe2+, resulting from the immunoreaction between CRP and anti-CRP. Under optimal conditions, the present immunoassay measures CRP in a linear range from 0.4–200 nM (0.047–23.6 µg mL−1, with a detection limit of 0.15 nM (17 ng mL−1, S/N = 3 and sensitivity of 90.7 nA nM−1, in addition to a good reproducibility and storage stability. The analytical applicability of the presented immunoassay is verified by CRP measurements in human blood serum samples. This work provides the basis for a low-priced, safe, and easy-to-use point-of-care immunosensor assay to measure CRP at clinically relevant concentrations.

  19. Advanced techniques in immunoassay

    International Nuclear Information System (INIS)

    Toth, G.

    1982-01-01

    A brief overview of the development history of radioimmunoassay and related techniques with their theory and practice are given. A comparison of radioimmunoassay (RIA), enzyme immunoassay (EIA), spin immunoassay (SIA), sequential saturation analysis (SSA) etc., based on their main parameters, and their fields of application and recent trends are presented. (Sz.J.)

  20. Microfluidic Platform for Enzyme-Linked and Magnetic Particle-Based Immunoassay

    Directory of Open Access Journals (Sweden)

    Dorota G. Pijanowska

    2013-06-01

    Full Text Available This article presents design and testing of a microfluidic platform for immunoassay. The method is based on sandwiched ELISA, whereby the primary antibody is immobilized on nitrocelluose and, subsequently, magnetic beads are used as a label to detect the analyte. The chip takes approximately 2 h and 15 min to complete the assay. A Hall Effect sensor using 0.35-μm BioMEMS TSMC technology (Taiwan Semiconductor Manufacturing Company Bio-Micro-Electro-Mechanical Systems was fabricated to sense the magnetic field from the beads. Furthermore, florescence detection and absorbance measurements from the chip demonstrate successful immunoassay on the chip. In addition, investigation also covers the Hall Effect simulations, mechanical modeling of the bead–protein complex, testing of the microfluidic platform with magnetic beads averaging 10 nm, and measurements with an inductor-based system.

  1. Radiolabelling for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Since the early 1960s labelled compounds employed in immunoassay techniques, both radioimmunoassay and immunoradiometric assay, have involved radioisotopes typically 3 H (tritium) and 125 Iodine. With the advent of increasingly stringent governmental regulations regarding usage and disposal of radioisotopes and the impetus of research towards improved immunoassay sensitivity following the discovery of monoclonal antibodies and their application to excess reagent immunometric assay methodology, radioisotopic labels are gradually being replaced by non-isotopic labels: enzyme, fluorescence and chemiluminescence

  2. Design and Fabrication of a PDMS Microchip Based Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Wang, Wanjun; Wang, Jun; Lin, Yuehe

    2010-07-01

    In this paper, we describe the design and fabrication process of a polydimethylsiloxane (PDMS) microchip for on-chip multiplex immunoassay application. The microchip consists of a PDMS microfluidic channel layer and a micro pneumatic valve control layer. By selectively pressurizing the pneumatic microvalves, immuno reagents were controlled to flow and react in certain fluidic channel sites. Cross contamination was prevented by tightly closed valves. Our design was proposed to utilize PDMS micro channel surface as the solid phase immunoassay substrate and simultaneously detect four targets antigens on chip. Experiment result shows that 20psi valve pressure is sufficient to tightly close a 200µm wide micro channel with flow rate up to 20µl/min.

  3. Development of a Highly Specific Fluorescence Immunoassay for Detection of Diisobutyl Phthalate in Edible Oil Samples.

    Science.gov (United States)

    Cui, Xiping; Wu, Panpan; Lai, Dan; Zheng, Shengwu; Chen, Yingshan; Eremin, Sergei A; Peng, Wei; Zhao, Suqing

    2015-10-28

    The diisobutyl phthalate (DiBP) hapten containing an amino group was synthesized successfully, and the polyclonal antibody against 4-amino phthalate-bovine serum albumin (BSA) was developed. On the basis of the polyclonal antibody, a rapid and sensitive indirect competitive fluorescence immunoassay (icFIA) has been established to detect DiBP in edible oil samples for the first time. Under the optimized conditions, the quantitative working range of the icFIA was from 10.47 to 357.06 ng/mL (R(2) = 0.991), exhibiting a detection limit of 5.82 ng/mL. In this assay, the specific results showed that other similar phthalates did not significantly interfere with the analysis, with the cross-reactivity less than 1.5%, except for that of DiBAP. Thereafter, DiBP contamination in edible oil samples was detected by icFIA, with the recovery being from 79 to 103%. Furthermore, the reliability of icFIA was validated by gas chromatography-mass spectrometry (GC-MS). Therefore, the developed icFIA is suitable for monitoring DiBP in some edible oil samples.

  4. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    Science.gov (United States)

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574

  5. Development of a chip-based multiplexed immunoassay using liposomal nanovesicles and its application in the detection of pathogens causing female lower genital tract infections

    Directory of Open Access Journals (Sweden)

    Wen-Hsiang Su

    2013-03-01

    Conclusion: This microarray chip was a rapid, easy, inexpensive and sensitive tool for detecting female lower genital tract Candida infection in a one-time vaginal sampling process, although the data on the four other pathogens were still unavailable. A larger population study is encouraged to test the validity of this multiplexed immunoassay chip.

  6. Biosensor immunoassay for flumequine in broiler serum and muscle

    NARCIS (Netherlands)

    Haasnoot, W.; Gercek, H.; Cazemier, G.; Nielen, M.W.F.

    2007-01-01

    Flumequine (Flu) is one of the fluoroquinolones most frequently applied for the treatment of broilers in The Netherlands. For the detection of residues of Flu in blood serum of broilers, a biosensor immunoassay (BIA) was developed which was fast (7.5 min per sample) and specific (no cross-reactivity

  7. Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads.

    Science.gov (United States)

    Tang, Dianping; Su, Biling; Tang, Juan; Ren, Jingjing; Chen, Guonan

    2010-02-15

    A novel nanoparticle-based electrochemical immunoassay of carbohydrate antigen 125 (CA125) as a model was designed to couple with a microfluidic strategy using anti-CA125-functionalized magnetic beads as immunosensing probes. To construct the immunoassay, thionine-horseradish peroxidase conjugation (TH-HRP) was initially doped into nanosilica particles using the reverse micelle method, and then HRP-labeled anti-CA125 antibodies (HRP-anti-CA125) were bound onto the surface of the synthesized nanoparticles, which were used as recognition elements. Different from conventional nanoparticle-based electrochemical immunoassays, the recognition elements of the immunoassay simultaneously contained electron mediator and enzyme labels and simplified the electrochemical measurement process. The sandwich-type immunoassay format was used for the online formation of the immunocomplex in an incubation cell and captured in the detection cell with an external magnet. The electrochemical signals derived from the carried HRP toward the reduction of H(2)O(2) using the doped thionine as electron mediator. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.1 to 450 U/mL with a detection limit of 0.1 U/mL CA125. The precision, reproducibility, and stability of the immunoassay were acceptable. The assay was evaluated for clinical serum samples, receiving in excellent accordance with results obtained from the standard enzyme-linked immunosorbent assay (ELISA) method. Concluding, the nanoparticle-based assay format provides a promising approach in clinical application and thus represents a versatile detection method.

  8. Detection of Pesticides and Pesticide Metabolites Using the Cross Reactivity of Enzyme Immunoassays

    Science.gov (United States)

    Thurman, E.M.; Aga, D.S.

    2001-01-01

    Enzyme immunoassay is an important environmental analysis method that may be used to identify many pesticide analytes in water samples. Because of similarities in chemical structure between various members of a pesticide class, there often may be an unwanted response that is characterized by a percentage of cross reactivity. Also, there may be cross reactivity caused by degradation products of the target analyte that may be present in the sample. In this paper, the concept of cross reactivity caused by degradation products or by nontarget analytes is explored as a tool for identification of metabolites or structurally similar compounds not previously known to be present in water samples. Two examples are examined in this paper from various water quality studies. They are alachlor and its metabolite, alachlor ethane sulfonic acid, and atrazine and its class members, prometryn and propazine. A method for using cross reactivity for the detection of these compounds is explained in this paper.

  9. Screening for cocaine on Euro banknotes by a highly sensitive enzyme immunoassay.

    Science.gov (United States)

    Abdelshafi, Nahla A; Panne, Ulrich; Schneider, Rudolf J

    2017-04-01

    This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Cross-reactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1cm 2 of one banknote by swabbing 1cm 2 : 0, 14, and 21pg/cm 2 . Moreover, three notes of different denominations revealed high cocaine concentration; 1.1mg/note, and twice 55µg/note. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Comparison of the performance of five different immunoassays to detect specific antibodies against emerging atypical bovine pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Liu, Lihong

    2013-01-01

    Bovine pestiviruses represent a considerably variable group. In addition to the two accepted species BVDV-1 and BVDV-2, a number of atypical bovine pestiviruses have been detected both in foetal calf sera and in field samples. The sera collected during the initial six weeks of experimental...... infection of calves with atypical pestivirus, BVDV-1 and a combination of both viruses have been examined by routine and new diagnostic tests to validate their robustness and sensitivity. As expected, virus neutralization tests using homologous virus were able to differentiate the two groups infected...... by BVDV-1 or atypical pestivirus, whereas the animals inoculated with a mixture of these two viruses had a reaction pattern very similar to the homologous virus alone. It was found that immunoassays using whole virus and polyclonal antibodies are the most robust, but all tests examined were able to detect...

  11. Sensitivity-Enhancement of FRET Immunoassays by Multiple-Antibody Conjugation on Quantum Dots.

    Science.gov (United States)

    Annio, Giacomo; Jennings, Travis; Tagit, Oya; Hildebrandt, Niko

    2018-05-23

    Quantum dots (QDs) are not only advantageous for color-tuning, improved brightness, and high stability, but their nanoparticle surfaces also allow for the attachment of many biomolecules. Because IgG antibodies (ABs) are in the same size range of biocompatible QDs and the AB orientation after conjugation to the QD is often random, it is difficult to predict if few or many ABs per QD will lead to an efficient AB-QD conjugate. This is particularly true for homogeneous Förster resonance energy transfer (FRET) sandwich immunoassays, for which the ABs on the QD must bind a biomarker that needs to bind a second AB-FRET-conjugate. Here, we investigate the performance of Tb-to-QD FRET immunoassays against total prostate specific antigen (TPSA) by changing the number of ABs per QD while leaving all the other assay components unchanged. We first characterize the AB-QD conjugation by various spectroscopic, microscopic, and chromatographic techniques and then quantify the TPSA immunoassay performance regarding sensitivity, limit of detection, and dynamic range. Our results show that an increasing conjugation ratio leads to significantly enhanced FRET immunoassays. These findings will be highly important for developing QD-based immunoassays in which the concentrations of both ABs and QDs can significantly influence the assay performance.

  12. Specific detection of Vibrio parahaemolyticus by fluorescence quenching immunoassay based on quantum dots.

    Science.gov (United States)

    Wang, Ling; Zhang, Junxian; Bai, Haili; Li, Xuan; Lv, Pintian; Guo, Ailing

    2014-07-01

    In this study, anti-Vibrio parahaemolyticus polyclonal and monoclonal antibodies were prepared through intradermal injection immune and lymphocyte hybridoma technique respectively. CdTe quantum dots (QDs) were synthesized at pH 9.3, 98 °C for 1 h with stabilizer of 2.7:1. The fluorescence intensity was 586.499, and the yield was 62.43%. QD probes were successfully prepared under the optimized conditions of pH 7.4, 37 °C for 1 h, 250 μL of 50 mg/mL EDC · HCl, 150 μL of 4 mg/mL NHS, buffer system of Na2HPO4-citric acid, and 8 μL of 2.48 mg/mL polyclonal antibodies. As gold nanoparticles could quench fluorescence of quantum dots, the concentration of V. parahaemolyticus could be detected through measuring the reduction of fluorescence intensity in immune sandwich reaction composed of quantum dot probe, gold-labeled antibody, and the sample. For pure culture, fluorescence intensity of the system was proportional with logarithm concentration of antigen, and the correlation coefficient was 99.764%. The fluorescence quenching immunoassay based on quantum dots is established for the first time to detect Vibrio parahaemolyticus. This method may be used as rapid testing procedure due to its high simplicity and sensitivity.

  13. Development of a prototype lateral flow immunoassay (LFI for the rapid diagnosis of melioidosis.

    Directory of Open Access Journals (Sweden)

    Raymond L Houghton

    2014-03-01

    Full Text Available Burkholderia pseudomallei is a soil-dwelling bacterium and the causative agent of melioidosis. Isolation of B. pseudomallei from clinical samples is the "gold standard" for the diagnosis of melioidosis; results can take 3-7 days to produce. Alternatively, antibody-based tests have low specificity due to a high percentage of seropositive individuals in endemic areas. There is a clear need to develop a rapid point-of-care antigen detection assay for the diagnosis of melioidosis. Previously, we employed In vivo Microbial Antigen Discovery (InMAD to identify potential B. pseudomallei diagnostic biomarkers. The B. pseudomallei capsular polysaccharide (CPS and numerous protein antigens were identified as potential candidates. Here, we describe the development of a diagnostic immunoassay based on the detection of CPS. Following production of a CPS-specific monoclonal antibody (mAb, an antigen-capture immunoassay was developed to determine the concentration of CPS within a panel of melioidosis patient serum and urine samples. The same mAb was used to produce a prototype Active Melioidosis Detect Lateral Flow Immunoassay (AMD LFI; the limit of detection of the LFI for CPS is comparable to the antigen-capture immunoassay (∼0.2 ng/ml. The analytical reactivity (inclusivity of the AMD LFI was 98.7% (76/77 when tested against a large panel of B. pseudomallei isolates. Analytical specificity (cross-reactivity testing determined that 97.2% of B. pseudomallei near neighbor species (35/36 were not reactive. The non-reactive B. pseudomallei strain and the reactive near neighbor strain can be explained through genetic sequence analysis. Importantly, we show the AMD LFI is capable of detecting CPS in a variety of patient samples. The LFI is currently being evaluated in Thailand and Australia; the focus is to optimize and validate testing procedures on melioidosis patient samples prior to initiation of a large, multisite pre-clinical evaluation.

  14. Survey of immunoassay techniques for biological analysis

    International Nuclear Information System (INIS)

    Burtis, C.A.

    1986-10-01

    Immunoassay is a very specific, sensitive, and widely applicable analytical technique. Recent advances in genetic engineering have led to the development of monoclonal antibodies which further improves the specificity of immunoassays. Originally, radioisotopes were used to label the antigens and antibodies used in immunoassays. However, in the last decade, numerous types of immunoassays have been developed which utilize enzymes and fluorescent dyes as labels. Given the technical, safety, health, and disposal problems associated with using radioisotopes, immunoassays that utilize the enzyme and fluorescent labels are rapidly replacing those using radioisotope labels. These newer techniques are as sensitive, are easily automated, have stable reagents, and do not have a disposal problem. 6 refs., 1 fig., 2 tabs

  15. Comparison of infrared-excited up-converting phosphors and europium nanoparticles as labels in a two-site immunoassay

    International Nuclear Information System (INIS)

    Ukonaho, Telle; Rantanen, Terhi; Jaemsen, Laura; Kuningas, Katri; Paekkilae, Henna; Loevgren, Timo; Soukka, Tero

    2007-01-01

    Research in the field of immunoassays and labels used in the detection has been recently focused on particulate reporters, which possess very high specific activity that excludes the label as a sensitivity limiting factor. However, the large size and shape of the particulate labels may produce additional problems to immunoassay performance. The aim of this work was to study with two identical non-competitive two-site immunoassays whether up-converting phosphor (UCP) particles are comparable in performance with europium(III) chelate-dyed nanoparticles as particulate labels. In addition we strived to verify the common assumption of the photostability of up-converting phosphor particles supporting their potential applicability in imaging. Detection limits in two-site immunoassay for free prostate-specific antigen (free-PSA) were 0.53 ng L -1 and 1.3 ng L -1 using two different up-converting phosphors and 0.16 ng L -1 using europium(III) nanoparticle. Large size distribution and non-specific binding of up-converting phosphor particles caused assay variation in low analyte concentrations and limited the analytical detection limit. The non-specific binding was the major factor limiting the analytical sensitivity of the immunoassay. The results suggests the need for nanoscaled and uniformely sized UCP-particles to increace the sensitivity and applicability of up-converting phosphor particles. Anti-Stokes photoluminescence of up-converting phosphor particles did not photobleach when measured repeatedly, on the contrary, the time-resolved fluorescence of europium nanoparticles photobleached relatively rapidly

  16. A bare-eye-based lateral flow immunoassay based on the use of gold nanoparticles for simultaneous detection of three pesticides

    International Nuclear Information System (INIS)

    Wang, Limin; Cai, Jia; Wang, Yulong; Fang, Qingkui; Wang, Suyan; Cheng, Qi; Liu, Fengquan; Du, Dan; Lin, Yuehe

    2014-01-01

    We present a novel lateral flow immunoassay (LFIA) for the simultaneous detection of the pesticides imidacloprid, chlorpyrifos-methyl and isocarbophos based on three competitive immunoreactions. In contrast to previously reported LFIAs, the method is based on the use of four strips. Each has three red channels (three test lines dispensed with different capture reagent) to detect imidacloprid, chlorpyrifos-methyl and isocarbophos respectively. Different channels on each strip are the key to multi-detection, and four strips of LFIA are needed for visual and semi-quantitative read-outs. Under optimized conditions, the LFIA was applied to the determination of three pesticides. The detection time is within 7 min and the detection limits are 50, 100, and 100 μg L −1 , respectively. Furthermore, the LFIA was applied to the analysis of spiked Chinese cabbage and soil samples and results were validated by HPLC. (author)

  17. Studies on the metabolism and toxicological detection of the amphetamine-like anorectic fenproporex in human urine by gas chromatography-mass spectrometry and fluorescence polarization immunoassay.

    Science.gov (United States)

    Kraemer, T; Theis, G A; Weber, A A; Maurer, H H

    2000-01-28

    Studies on the metabolism and the toxicological analysis of fenproporex (R,S-3-[(1-phenyl-2-propyl)-amino]-propionitrile, FP) using GC-MS and fluorescence polarization immunoassay are described. The metabolites were identified in urine samples of volunteers by GC-MS after cleavage of conjugates, extraction and acetylation. Besides unchanged FP, fourteen metabolites, including amphetamine, could be identified. Two partially overlapping metabolic pathways could be postulated: ring degradation by one- and two-fold aromatic hydroxylation followed by methylation and side chain degradation by N-dealkylation to amphetamine (AM). A minor pathway leads via beta-hydroxylation of AM to norephedrine. For GC-MS detection, the systematic toxicological analysis procedure including acid hydrolysis, extraction at pH 8-9 and acetylation was suitable (detection limits 50 ng/ml for FP and 100 ng/ml for AM). Excretion studies showed, that only AM but neither FP nor its specific metabolites were detectable 30-60 h after ingestion of 20 mg of FP. Therefore, misinterpretation can occur. The Abbott TDx FPIA amphetamine/methamphetamine II gave positive results up to 58 h. All the positive immunoassay results could be confirmed by the described GC-MS procedure.

  18. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    Science.gov (United States)

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  19. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  20. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    Science.gov (United States)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  1. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I

    Energy Technology Data Exchange (ETDEWEB)

    Sirkka, Nina, E-mail: nkelon@utu.fi; Lyytikäinen, Annika; Savukoski, Tanja; Soukka, Tero

    2016-06-21

    Photon upconverting nanophosphors (UCNPs) have a unique capability to produce anti-Stokes emission at visible wavelengths via sequential multiphoton absorption upon infrared excitation. Since the anti-Stokes emission can be easily spectrally resolved from the Stokes' shifted autofluorescence, the upconversion luminescence (UCL) is a highly attractive reporter technology for optical biosensors and biomolecular binding assays – potentially enabling unprecedented sensitivity in separation-based solid-phase immunoassays. UCL technology has not previously been applied in sensitive detection of cardiac troponin I (cTnI), which requires highly sensitive detection to enable accurate and timely diagnosis of myocardial infarction. We have developed an UCL-based immunoassay for cTnI using NaYF{sub 4}: Yb{sup 3+}, Er{sup 3+} UCNPs as reporters. Biotinylated anti-cTnI monoclonal antibody (Mab) and Fab fragment immobilized to streptavidin-coated wells were used to capture cTnI. Captured cTnI was detected from dry well surface after a 15 min incubation with poly(acrylic acid) coated UCNPs conjugated to second anti-cTnI Mab. UCL was measured with a dedicated UCL microplate reader. The UCL-based immunoassay allowed sensitive detection of cTnI. The limit of detection was 3.14 ng L{sup −1}. The calibration curve was linear up to cTnI concentration 50,000 ng L{sup −1}. Plasma recoveries of added cTnI were 92–117%. Obtained cTnI concentrations from five normal plasma samples were 4.13–10.7 ng L{sup −1} (median 5.06 ng L{sup −1}). There is yet significant potential for even further improved limit of detection by reducing non-specifically bound fraction of the Mab-conjugated UCNPs. The assay background with zero calibrator was over 40-fold compared to the background obtained from wells where the reporter conjugate had been excluded. - Highlights: • Detection of attomole analyte quantity in microwell using upconversion luminescence. • Upconverting

  2. First application of a microsphere-based immunoassay to the detection of genetically modified organisms (GMOs): quantification of Cry1Ab protein in genetically modified maize.

    Science.gov (United States)

    Fantozzi, Anna; Ermolli, Monica; Marini, Massimiliano; Scotti, Domenico; Balla, Branko; Querci, Maddalena; Langrell, Stephen R H; Van den Eede, Guy

    2007-02-21

    An innovative covalent microsphere immunoassay, based on the usage of fluorescent beads coupled to a specific antibody, was developed for the quantification of the endotoxin Cry1Ab present in MON810 and Bt11 genetically modified (GM) maize lines. In particular, a specific protocol was developed to assess the presence of Cry1Ab in a very broad range of GM maize concentrations, from 0.1 to 100% [weight of genetically modified organism (GMO)/weight]. Test linearity was achieved in the range of values from 0.1 to 3%, whereas fluorescence signal increased following a nonlinear model, reaching a plateau at 25%. The limits of detection and quantification were equal to 0.018 and 0.054%, respectively. The present study describes the first application of quantitative high-throughput immunoassays in GMO analysis.

  3. Routinely used immunoassays do not detect circulating anti-GBM antibodies against native NC1 hexamer and EA epitope of the α3 chain of type IV collagen.

    Science.gov (United States)

    Clavarino, Giovanna; Gauthier, Arnaud; Hellmark, Thomas; Carron, Pierre-Louis; Giovannini, Diane; Colliard, Sophie; Dragon-Durey, Marie-Agnès; Segelmark, Mårten; Cesbron, Jean-Yves; Dumestre-Pérard, Chantal

    2018-04-12

    Detection of circulating anti-GBM antibodies has a key role for the diagnosis of Goodpasture syndrome but immunoassays using purified or recombinant alpha3(IV)NC1 as antigen do not recognize all anti-GBM antibodies. We show that anti-GBM antibodies directed against epitopes in their native conformation or cryptic epitopes are detected by indirect immunofluorescence. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Evaluation of the microparticle enzyme immunoassay Abbott IMx Select Chlamydia and the importance of urethral site sampling to detect Chlamydia trachomatis in women.

    OpenAIRE

    Brokenshire, M K; Say, P J; van Vonno, A H; Wong, C

    1997-01-01

    OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical cell culture. Also, to determine whether sampling the urethral site is an important part of chlamydial diagnosis in women. SETTING: The Auckland, Manukau, and Waitakere Sexual Health Clinics, Auckland, New Zealand and the Department of Clinical Microbiology, Auckland Hospital, Auckland, ...

  5. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  6. An enzyme immunoassay to quantify neurofilament light chain in cerebrospinal fluid.

    NARCIS (Netherlands)

    Geel, W.J.A. van; Rosengren, L.E.; Verbeek, M.M.

    2005-01-01

    Neurofilament light chain is a component of the axonal cytoskeleton. The concentration of the neurofilament light chain in cerebrospinal fluid may reflect axonal damage or the extent of white matter damage. In this study we describe a sensitive immunoassay for the detection of neurofilament light

  7. A Novel Colorimetric Immunoassay Utilizing the Peroxidase Mimicking Activity of Magnetic Nanoparticles

    Directory of Open Access Journals (Sweden)

    Hyun Gyu Park

    2013-05-01

    Full Text Available A simple colorimetric immunoassay system, based on the peroxidase mimicking activity of Fe3O4 magnetic nanoparticles (MNPs, has been developed to detect clinically important antigenic molecules. MNPs with ca. 10 nm in diameter were synthesized and conjugated with specific antibodies against target molecules, such as rotaviruses and breast cancer cells. Conjugation of the MNPs with antibodies (MNP-Abs enabled specific recognition of the corresponding target antigenic molecules through the generation of color signals arising from the colorimetric reaction between the selected peroxidase substrate, 3,3',5,5'-tetramethylbenzidine (TMB and H2O2. Based on the MNP-promoted colorimetric reaction, the target molecules were detected and quantified by measuring absorbance intensities corresponding to the oxidized form of TMB. Owing to the higher stabilities and economic feasibilities of MNPs as compared to horseradish peroxidase (HRP, the new colorimetric system employing MNP-Abs has the potential of serving as a potent immunoassay that should substitute for conventional HRP-based immunoassays. The strategy employed to develop the new methodology has the potential of being extended to the construction of simple diagnostic systems for a variety of biomolecules related to human cancers and infectious diseases, particularly in the realm of point-of-care applications.

  8. Homogeneous immunoassay for human IgG using oriented hen egg IgY immobilized on gold sol nanoparticles

    International Nuclear Information System (INIS)

    Yeritsyan, H.E.; Gasparyan, V.K.

    2012-01-01

    Homogeneous immunoassays using (red) gold nanoparticles represent an attractive detection scheme because of the option of photometric readout. We have applied oriented immobilization of hen egg immunoglobulin Y (IgY) on gold nanoparticles when developing a homogeneous immunoassay for human IgG. In oriented immobilization, as opposed to random immobilization, the antigen binding capabilities of the antibodies are retained. It is shown that such immunoassay has significantly better sensitivity in comparison with methods based on conventional immobilization of affinity-purified antibodies. It is also shown that hen egg IgY is better suited than rabbit antibodies, because much more antibody can be immobilized on gold nanoparticles without any destabilization, probably because of the more acidic nature of these antibodies. In addition, hen egg IgY can be supplied in higher quantity and can be prepared more easily than IgG from rabbits. Bleeding and slaughtering of animals is not needed. The assay presented here has a wide detection range (30-500 ng. mL -1 ) and a limit of detection as low as 30 ng. mL -1 of human IgG. (author)

  9. Comparison among performances of a ligase chain reaction-based assay and two enzyme immunoassays in detecting Chlamydia trachomatis in urine specimens from men with nongonococcal urethritis.

    Science.gov (United States)

    Deguchi, T; Yasuda, M; Uno, M; Tada, K; Iwata, H; Komeda, H; Maeda, S; Latila, V; Saito, I; Kawada, Y

    1996-01-01

    We evaluated the performances of a ligase chain reaction (LCR)-based assay and two enzyme immunoassays (Chlamydiazyme and IDEIA) in the detection of Chlamydia trachomatis in urine specimens. We compared the results of testing urine specimens by these assays with those of urethral swab culture by examining samples from 131 men with nongonococcal urethritis. Discrepant results were analyzed by testing urethral swab specimens for C. trachomatis by a PCR-based assay. After the resolution of discrepant results, the sensitivity of urethral swab culture was 85.3%, whereas those of the LCR assay, Chlamydiazyme, and IDEIA with urine specimens were 94.1, 82.4, and 94.1%, respectively. The LCR assay and IDEIA were more sensitive than was urethral swab culture. In addition, the LCR assay, with a sensitivity equal to that of IDEIA, was more specific. Overall, the LCR assay proved to be superior to the enzyme immunoassays in detecting C. trachomatis in urine specimens. Testing urine specimens by LCR assay should be a helpful alternative method for diagnosing C. trachomatis urethral infection in men with nongonococcal urethritis. PMID:8784574

  10. Domestic cat microsphere immunoassays: detection of antibodies during feline immunodeficiency virus infection.

    Science.gov (United States)

    Wood, Britta A; Carver, Scott; Troyer, Ryan M; Elder, John H; VandeWoude, Sue

    2013-10-31

    Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9 and 28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. © 2013.

  11. Hydrogel nanoparticle based immunoassay

    Science.gov (United States)

    Liotta, Lance A; Luchini, Alessandra; Petricoin, Emanuel F; Espina, Virginia

    2015-04-21

    An immunoassay device incorporating porous polymeric capture nanoparticles within either the sample collection vessel or pre-impregnated into a porous substratum within fluid flow path of the analytical device is presented. This incorporation of capture particles within the immunoassay device improves sensitivity while removing the requirement for pre-processing of samples prior to loading the immunoassay device. A preferred embodiment is coreshell bait containing capture nanoparticles which perform three functions in one step, in solution: a) molecular size sieving, b) target analyte sequestration and concentration, and c) protection from degradation. The polymeric matrix of the capture particles may be made of co-polymeric materials having a structural monomer and an affinity monomer, the affinity monomer having properties that attract the analyte to the capture particle. This device is useful for point of care diagnostic assays for biomedical applications and as field deployable assays for environmental, pathogen and chemical or biological threat identification.

  12. Silver nanoparticles deposited on graphene oxide for ultrasensitive surface-enhanced Raman scattering immunoassay of cancer biomarker.

    Science.gov (United States)

    Yang, Lin; Zhen, Shu Jun; Li, Yuan Fang; Huang, Cheng Zhi

    2018-06-14

    Graphene oxide (GO) exhibits distinctive Raman scattering features for its high frequency D (disordered) and tangential modes (G-band), which are characteristically sharp at 1580 cm-1 and 1350 cm-1, respectively, but are too weak for sensitive quantitation purposes. By depositing silver nanoparticles on the surface of GO in this contribution, both D and G bands of GO become enhanced. The enzyme label of this method controls the dissolution of silver nanoparticles on the surface of GO through hydrogen peroxide which is produced by the oxidation of the enzyme substrate. With the dissolution of the silver nanoparticles a greatly decreased SERS signal of GO was obtained. This strategy involves dual signal amplification of the enzyme and nanocomposites to improve the detection sensitivity. As a proof of concept, prostate specific antigen (PSA), a biomarker for prostate cancer, is successfully detected as a target by forming a sandwich structure in immunoassay. The SERS immunoassay possesses excellent analytical performance in the range 0.5 pg mL-1 to 500 pg mL-1 with a limit of detection of 0.23 pg mL-1, making the detection of PSA serum samples from prostate cancer patients satisfactory, demonstrating that the sensitive enzyme-assisted dissolved AgNPs SERS immunoassay of PSA has potential applications in clinical diagnosis.

  13. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Magnetofluorescent nanocomposites and quantum dots used for optimal application in magnetic fluorescence-linked immunoassay.

    Science.gov (United States)

    Tsai, H Y; Li, S Y; Fuh, C Bor

    2018-03-01

    Magnetofluorescent nanocomposites with optimal magnetic and fluorescent properties were prepared and characterized by combining magnetic nanoparticles (iron oxide@polymethyl methacrylate) with fluorescent nanoparticles (rhodamine 6G@mSiO 2 ). Experimental parameters were optimized to produce nanocomposites with high magnetic susceptibility and fluorescence intensity. The detection of a model biomarker (alpha-fetoprotein) was used to demonstrate the feasibility of applying the magnetofluorescent nanocomposites combined with quantum dots and using magnetic fluorescence-linked immunoassay. The magnetofluorescent nanocomposites enable efficient mixing, fast re-concentration, and nanoparticle quantization for optimal reactions. Biofunctional quantum dots were used to confirm the alpha-fetoprotein (AFP) content in sandwich immunoassay after mixing and washing. The analysis time was only one third that required in ELISA. The detection limit was 0.2 pg mL -1 , and the linear range was 0.68 pg mL -1 -6.8 ng mL -1 . This detection limit is lower, and the linear range is wider than those of ELISA and other methods. The measurements made using the proposed method differed by less than 13% from those obtained using ELISA for four AFP concentrations (0.03, 0.15, 0.75, and 3.75 ng mL -1 ). The proposed method has a considerable potential for biomarker detection in various analytical and biomedical applications. Graphical abstract Magnetofluorescent nanocomposites combined with fluorescent quantum dots were used in magnetic fluorescence-linked immunoassay.

  15. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.

    Science.gov (United States)

    Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim

    2015-03-01

    To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. The right environment for the immunoassay

    International Nuclear Information System (INIS)

    Emon, J.M. Van; Gerlach, C.L.

    1995-01-01

    For the US Environmental Protection Agency (EPA), the first in-house research effort began in 1987, when results of an early immunoassay field study verified the technology's potential for environmental applications. Looking at the fundamental features of immunochemical reactions from the clinical laboratories, analytical chemists realized the potential value of these methods for hazardous waste site characterization and pesticide monitoring. Immunoassays rely on the interaction between an antibody and a target analyte. For environmental purposes, enzyme immunoassays are generally used. After the target analyte binds to the antibody, an enzymatic reaction yields a colorimetric change. This change, read visually or by a spectrophotometer, indicates the concentration of the target analyte. Promising results with assays for compounds (such as paraquat and pentachlorophenol) and compound groups (such as total petroleum hydrocarbons and polychlorinated biphenyls) spurred interest among various entrepreneurs. The first target market for immunoassays was environmental engineers and field crews who needed quick answers on-site to determine the direction of further remediation efforts

  17. Enhancing the lateral-flow immunoassay for detection of proteins using an aqueous two-phase micellar system.

    Science.gov (United States)

    Mashayekhi, Foad; Le, Alexander M; Nafisi, Parsa M; Wu, Benjamin M; Kamei, Daniel T

    2012-10-01

    The lateral-flow (immuno)assay (LFA) has been widely investigated for the detection of molecular, macromolecular, and particle targets at the point-of-need due to its ease of use, rapid processing, and minimal power and laboratory equipment requirements. However, for some analytes, such as certain proteins, the detection limit of LFA is inferior to lab-based assays, such as the enzyme-linked immunosorbent assay, and needs to be improved. One solution for improving the detection limit of LFA is to concentrate the target protein in a solution prior to the detection step. In this study, a novel approach was used in the context of an aqueous two-phase micellar system comprised of the nonionic surfactant Triton X-114 to concentrate a model protein, namely transferrin, prior to LFA. Proteins have been shown to partition, or distribute, fairly evenly between the two phases of an aqueous two-phase system, which in turn results in their limited concentration in one of the two phases. Therefore, larger colloidal gold particles decorated with antibodies for transferrin were used in the concentration step to bind to transferrin and aid its partitioning into the top, micelle-poor phase. By manipulating the volume ratio of the two coexisting micellar phases and combining the concentration step with LFA, the transferrin detection limit of LFA was improved by tenfold from 0.5 to 0.05 μg/mL in a predictive manner. In addition to enhancing the sensitivity of LFA, this universal concentration method could also be used to improve other detection assays.

  18. Comparative evaluation of the Ridascreen Verotoxin enzyme immunoassay for detection of Shiga-toxin producing strains of Escherichia coli (STEC) from food and other sources.

    Science.gov (United States)

    Beutin, L; Steinrück, H; Krause, G; Steege, K; Haby, S; Hultsch, G; Appel, B

    2007-03-01

    To evaluate the suitability of the commercially distributed Ridascreen Verotoxin enzyme immunoassay (EIA) for detection of known genetic types of the Vero (Shiga) toxins 1 (Stx1) and 2 (Stx2) families and to determine its relative sensitivity and specificity. The Ridascreen-EIA was compared with the Vero cell assay, a P(1)-glycoprotein receptor EIA and with stx gene-specific PCs for detection of Stx with 43 Shiga toxin-producing strains of Escherichia coli (STEC) reference strains and with 241 test strains. The Ridascreen-EIA detects strains producing Stx1 and variants Stx1c and Stx1d, as well as Stx2 and variants Stx2d1, Stx2d2, Stx2e, Stx2d, Stx2-O118 (Stx2d-ount), Stx2-NV206, Stx2f and Stx2g. The assay showed a relative sensitivity of 95.7% and a relative specificity of 98.7%. Some of the Stx2-O118-, Stx2e- and Stx2g-producing STEC were not detected with the Ridascreen-EIA probably because of low amount of toxin produced by these strains. The Ridascreen-EIA is able to detect all known types of Stx and is applicable for routine screening of bacterial isolates owing to its high specificity. It is less applicable for testing samples where low amounts of Stx are expected, such as mixed cultures and certain Stx2 variants. This study presents a first comprehensive evaluation of the Ridascreen-EIA, a rapid standardized STEC screening test for routine diagnostic laboratories. Data are presented on the type of the spectrum of Stx that are detected with this immunoassay and its advantages and limits for practical use.

  19. A review of promising new immunoassay technology for monitoring forest herbicides

    Science.gov (United States)

    Charles K. McMahon

    1993-01-01

    Rising costs of classical instrumental methods of chemical analysis coupled with an increasing need for environmental monitoring has lead to the development of highly sensitive, low-cost immunochemical methods of analysis for the detection of environmental contaminants. These methods known simply as immunoassays are chemical assays which use antibodies as reagents. A...

  20. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  1. A radioligand immunoassay for 1,25-dihydroxyvitamin D3 receptors using monoclonal antibody: detection of a phenotypic receptor variant in vitamin D-dependency rickets (type II) which does not bind hormone

    International Nuclear Information System (INIS)

    Pike, J.W.; Dokoh, Shigeharu; Liberman, U.A.; Eil, C.; Haussler, M.R.; Marx, S.J.

    1984-01-01

    Vitamin D-dependency rickets, type II (VDDRII), is a well recognized heritable disorder characterized by peripheral target organ resistance to 1,25-dihydroxyvitamin D 3 (1,25(OH) 2 D 3 ), the hormonally active form of the vitamin. Recently, cultured skin fibroblasts obtained from a number of patients with VDDRII have been utilized to characterize the underlying molecular defects associated with this malady. Recently monoclonal antibodies to the vitamin D receptor have been generated, and a radioligand immunoassay (RLIA) for the detection of this molecule has been developed which is independent of its hormone-binding capacity. This report describes the application of the immunoassay in the detection of receptor-like molecules in fibroblasts derived from patients with VDDRII. The results indicate that the molecule is generally present in all patients, and provides a mechanism for individual responsiveness to pharmacologic treatment with vitamin D 3 metabolites. 8 refs.; 3 figs.; 1 table

  2. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    Science.gov (United States)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  3. Development of a screening fluorescence polarization immunoassay for the simultaneous detection of fumonisins B₁ and B₂ in maize.

    Science.gov (United States)

    Li, Chenglong; Mi, Tiejun; Conti, Gea Oliveri; Yu, Qing; Wen, Kai; Shen, Jianzhong; Ferrante, Margherita; Wang, Zhanhui

    2015-05-27

    This paper reports the development of a screening fluorescence polarization immunoassay (FPIA) for the simultaneous detection of fumonisins B1 (FB1) and B2 (FB2) in maize. Three FB1 tracers including FB1-fluorescein isothiocyanate isomer I (FB1-FITC), FB1-5-([4,6-dichlorotriazine-2-yl]amino)-fluorescein (FB1-5-DTAF), and FB1-Texas Red-X succinimidyl ester (FB1-TRX) were synthesized and studied to select appropriate tracer-antibody pairs using seven previously produced monoclonal antibodies (mAbs). An FPIA employing the pair of FB1-FITC and mAb 4B9 showing 98.9% cross-reactivity (CR) toward FB2 was used to simultaneously detect FB1 and FB2. Maize flour samples were extracted with methanol/water (2:3, v/v). After optimization, the FPIA revealed a limit of detection (LOD) of 157.4 μg/kg for FB1 and an LOD of 290.6 μg/kg for FB2, respectively. Recoveries were measured for spiked samples of FB1 or FB2 separately, ranging from 84.7 to 93.6%, with a coefficient of variation (CV) of fumonisins in maize.

  4. Metal-doped inorganic nanoparticles for multiplex detection of biomarkers by a sandwich-type ICP-MS immunoassay.

    Science.gov (United States)

    Ko, Jung Aa; Lim, H B

    2016-09-28

    Metal-doped inorganic nanoparticles were synthesized for the multiplex detection of biomarkers by a sandwich-type inductively coupled plasma mass spectrometry (ICP-MS) immunoassay. The synthesized Cs-doped multicore magnetic nanoparticles (MMNPs) were used not only for magnetic extraction of targets but also for ratiometric measurement in ICP-MS. In addition, three different metal/dye-doped silica nanoparticles (SNPs) were synthesized as probes for multiplex detection: Y/RhBITC (rhodamine B isothiocyanate)-doped SNPs for CRP (cardiovascular disease), Cd/RhBITC-doped SNPs for AFP (tumor), and Au/5(6)-XRITC (X-rhodamine-5-(and-6)-isothiocyanate)-doped SNPs for NSE (heart disease). For quantification, the doped metals of SNPs were measured by ICP-MS and then the signal ratio to Cs of MMNPs was plotted with respect to the concentration of targets by a ratiometry. Limits of detection (LOD) of 0.35 ng/mL to 77 ng mL(-1) and recoveries of 83%-125% were obtained for serum samples spiked with the biomarkers. Since no sample treatment was necessary prior to the extraction, the proposed method provided short analysis time and convenience for the multiplex determination of biomarkers, which will be valuable for clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Trends in interfacial design for surface plasmon resonance based immunoassays

    International Nuclear Information System (INIS)

    Shankaran, Dhesingh Ravi; Miura, Norio

    2007-01-01

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  6. Trends in interfacial design for surface plasmon resonance based immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Shankaran, Dhesingh Ravi [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan); Miura, Norio [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan)

    2007-12-07

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  7. On-Chip Immunoassay for Determination of Urinary Albumin

    OpenAIRE

    Laiwattanapaisal, Wanida; Songjaroen, Temsiri; Maturos, Thitima; Lomas, Tanom; Sappat, Assawapong; Tuantranont, Adisorn

    2009-01-01

    An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (...

  8. Multiplexed capillary microfluidic immunoassay with smartphone data acquisition for parallel mycotoxin detection.

    Science.gov (United States)

    Machado, Jessica M D; Soares, Ruben R G; Chu, Virginia; Conde, João P

    2018-01-15

    The field of microfluidics holds great promise for the development of simple and portable lab-on-a-chip systems. The use of capillarity as a means of fluidic manipulation in lab-on-a-chip systems can potentially reduce the complexity of the instrumentation and allow the development of user-friendly devices for point-of-need analyses. In this work, a PDMS microchannel-based, colorimetric, autonomous capillary chip provides a multiplexed and semi-quantitative immunodetection assay. Results are acquired using a standard smartphone camera and analyzed with a simple gray scale quantification procedure. The performance of this device was tested for the simultaneous detection of the mycotoxins ochratoxin A (OTA), aflatoxin B1 (AFB1) and deoxynivalenol (DON) which are strictly regulated food contaminants with severe detrimental effects on human and animal health. The multiplexed assay was performed approximately within 10min and the achieved sensitivities of<40, 0.1-0.2 and<10ng/mL for OTA, AFB1 and DON, respectively, fall within the majority of currently enforced regulatory and/or recommended limits. Furthermore, to assess the potential of the device to analyze real samples, the immunoassay was successfully validated for these 3 mycotoxins in a corn-based feed sample after a simple sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Evaluation of four immunoassays for diagnosis of brucellosis in Cuba

    International Nuclear Information System (INIS)

    Peraza, C.; Valdes, O.; Fonseca, N.; Garcia, M.; Alvarez, M.; Izquierdo, D.L.

    1998-01-01

    Four immunoassays (two indirect and two competitive ones) were evaluated by samples from areas free of disease, free by vaccination and affected areas using as reference techniques the Bengal Rose Tests, the Antigen in Buffered Plate Tests and the Complement Fixation Reaction Test. The evaluated samples demonstrated that the competitive assays (ELISAC-1 and ELISAC-2) detected less false positives than the indirect ones (ELISAI-1 and ELISAI-2). Of the competitive ELISAS, version 2 presented better sensitivity and specificity results in affected areas for 95% confidence: 80.9 - 96.9% and 97.5 - 99.4% respectively with positive predictive value in the range of 76 to 94% and negative predictive one between 98.1 and 99.7%. It was concluded that this assay can be used for brucellosis control because it gives higher assurance than the other evaluated immunoassays and it can discriminate infected from vaccinated animals. (author)

  10. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    Science.gov (United States)

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay.

    Directory of Open Access Journals (Sweden)

    Ricky Y T Chiu

    Full Text Available The paper-based immunoassay for point-of-care diagnostics is widely used due to its low cost and portability over traditional lab-based assays. Lateral-flow immunoassay (LFA is the most well-established paper-based assay since it is rapid and easy to use. However, the disadvantage of LFA is its lack of sensitivity in some cases where a large sample volume is required, limiting its use as a diagnostic tool. To improve the sensitivity of LFA, we previously reported on the concentration of analytes into one of the two bulk phases of an aqueous two-phase system (ATPS prior to detection. In this study, we preserved the advantages of LFA while significantly improving upon our previous proof-of-concept studies by employing a novel approach of concentrating gold nanoparticles, a common LFA colorimetric indicator. By conjugating specific antibodies and polymers to the surfaces of the particles, these gold nanoprobes (GNPs were able to capture target proteins in the sample and subsequently be concentrated within 10 min at the interface of an ATPS solution comprised of polyethylene glycol, potassium phosphate, and phosphate-buffered saline. These GNPs were then extracted and applied directly to LFA. By combining this prior ATPS interface extraction with LFA, the detection limit of LFA for a model protein was improved by 100-fold from 1 ng/μL to 0.01 ng/μL. Additionally, we examined the behavior of the ATPS system in fetal bovine serum and synthetic urine to more closely approach real-world applications. Despite using more complex matrices, ATPS interface extraction still improved the detection limit by 100-fold within 15 to 25 min, demonstrating the system's potential to be applied to patient samples.

  12. An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay.

    Science.gov (United States)

    Chiu, Ricky Y T; Thach, Alison V; Wu, Chloe M; Wu, Benjamin M; Kamei, Daniel T

    2015-01-01

    The paper-based immunoassay for point-of-care diagnostics is widely used due to its low cost and portability over traditional lab-based assays. Lateral-flow immunoassay (LFA) is the most well-established paper-based assay since it is rapid and easy to use. However, the disadvantage of LFA is its lack of sensitivity in some cases where a large sample volume is required, limiting its use as a diagnostic tool. To improve the sensitivity of LFA, we previously reported on the concentration of analytes into one of the two bulk phases of an aqueous two-phase system (ATPS) prior to detection. In this study, we preserved the advantages of LFA while significantly improving upon our previous proof-of-concept studies by employing a novel approach of concentrating gold nanoparticles, a common LFA colorimetric indicator. By conjugating specific antibodies and polymers to the surfaces of the particles, these gold nanoprobes (GNPs) were able to capture target proteins in the sample and subsequently be concentrated within 10 min at the interface of an ATPS solution comprised of polyethylene glycol, potassium phosphate, and phosphate-buffered saline. These GNPs were then extracted and applied directly to LFA. By combining this prior ATPS interface extraction with LFA, the detection limit of LFA for a model protein was improved by 100-fold from 1 ng/μL to 0.01 ng/μL. Additionally, we examined the behavior of the ATPS system in fetal bovine serum and synthetic urine to more closely approach real-world applications. Despite using more complex matrices, ATPS interface extraction still improved the detection limit by 100-fold within 15 to 25 min, demonstrating the system's potential to be applied to patient samples.

  13. Can LC and LC-MS ever replace immunoassays?

    Directory of Open Access Journals (Sweden)

    Timothy G. Cross

    2016-10-01

    Full Text Available Immunoassays have been the technology of choice for the analysis of biomolecules for many decades across a wide range of applications in research, diagnostics and infectious disease monitoring. There are good reasons for the wide adoption of immunoassays but even such a well established and characterised technique has limitations and as such investigators are looking at alternative technologies. One such alternative is liquid chromatography (LC and, more specifically, liquid chromatography coupled with mass spectrometry (LC-MS. This article will review both immunoassay and LC and LC-MS technologies and methodologies and discuss the advantages and limitations of both approaches. In addition, the next developments that will need to occur before there is widespread adoption of LC and LC-MS technology preferentially over immunoassays will be examined.

  14. Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)

    Science.gov (United States)

    Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul

    2000-03-01

    Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this

  15. Dot immunoassay for the simultaneous determination of postvaccination immunity against pertussis, diphtheria, and tetanus.

    Science.gov (United States)

    Khramtsov, Pavel; Bochkova, Maria; Timganova, Valeria; Zamorina, Svetlana; Rayev, Mikhail

    2017-06-01

    A dot immunoassay for simultaneous semiquantitative detection of IgG against tetanus toxoid (Ttx) and diphtheria toxoid (Dtx) and qualitative detection of anti-Bordetella pertussis IgGs in human blood serum using carbon nanoparticles functionalized with streptococcal protein G was developed. Inactivated B. pertussis cells in suspension form were used as an antigen in the immunoassay. Pertussis, tetanus, and diphtheria antigens were separately spotted onto nitrocellulose strips, and then the immunostrips were successively incubated with blood sera and a suspension of carbon nanoparticles. The immunostrips were then scanned with a flatbed scanner, and the images obtained were processed with ImageJ. One hundred fifty-five venous blood serum samples from children vaccinated with diphtheria, tetanus, and whole-cell pertussis (DTwP) vaccine were tested in comparison with a conventional ELISA and agglutination test. The total time required for analysis of 32 serum samples was less than 3 h. Comparison between the results of the dot immunoassay and the corresponding ELISA/agglutination test revealed a high level of agreement (Cohen's kappa between 0.765 and 0.813). The lower limit of quantification was 0.06 IU/ml for anti-Ttx and anti-Dtx. The intra-assay coefficients of variation were less than 15% for anti-Ttx and anti-Dtx and less than 10% for anti-pertussis. The diagnostic sensitivity of detection of the antibody protection level was 93.5% for anti-Ttx [95% confidence interval (CI) 83.5-97.9%], 92.4% for anti-Dtx (95% CI 80.9297.5%), and 90.2% for anti-pertussis (95% CI 75.9-96.8%). The diagnostic specificity was 90.9% for anti-Ttx (95% CI 57.1-99.5%), 85% for anti-Dtx (95% CI 61.1-96.0%), and 89.3% for anti-pertussis (95%CI 80.8-94.5%). The dot immunoassay developed does not require expensive reading equipment, and allows detection of antibodies against three antigens in a single analysis. The immunostrips can be stored for a long time without changes in the

  16. Catch and measure-mass spectrometry-based immunoassays in biomarker research.

    Science.gov (United States)

    Weiß, Frederik; van den Berg, Bart H J; Planatscher, Hannes; Pynn, Christopher J; Joos, Thomas O; Poetz, Oliver

    2014-05-01

    Mass spectrometry-based (MS) methods are effective tools for discovering protein biomarker candidates that can differentiate between physiological and pathophysiological states. Promising candidates are validated in studies comprising large patient cohorts. Here, targeted protein analytics are used to increase sample throughput. Methods involving antibodies, such as sandwich immunoassays or Western blots, are commonly applied at this stage. Highly-specific and sensitive mass spectrometry-based immunoassays that have been established in recent years offer a suitable alternative to sandwich immunoassays for quantifying proteins. Mass Spectrometric ImmunoAssays (MSIA) and Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA/iMALDI) are two prominent types of MS-based immunoassays in which the capture is done either at the protein or the peptide level. We present an overview of these emerging types of immunoassays and discuss their suitability for the discovery and validation of protein biomarkers. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  17. Deoxynivalenol-mimic nanobody isolated from a naïve phage display nanobody library and its application in immunoassay.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Bhunia, Arun K; Tu, Zhui; Chen, Bo; Liu, Yuan-Yuan

    2015-08-05

    In this study, using mycotoxin deoxynivalenol (DON) as a model hapten, we developed a nanobody-based environmental friendly immunoassay for sensitive detection of DON. Two nanobodies (N-28 and N-31) which bind to anti-DON monoclonal antibody (MAb) were isolated from a naive phage display library. These nanobodies are clonable, thermally stable and mycotoxin-free products and can be served as coating antigen mimetics in heterologous immunoassay. The half inhibition concentration (IC50) of the immunoassay developed with N-28 and N-31 was 8.77 ± 0.41 ng mL(-1) and 19.97 ± 0.84 ng mL(-1), respectively, which were 18- and 8-fold more sensitive than the conventional coating antigen (DON-BSA) based immunoassay. In order to better understand the molecular mechanism of antigen mimicry by nanobody, the 3D structure of "nanobody (N-28) - anti-DON MAb" complex was presented and verified by molecular modeling and alanine-scanning mutagenesis. The results showed that hydrogen bond and hydrophobic interaction formed between Thr 102 - Ser 106 of N-28 and CDR H3 residues of anti-DON antibody may contribute to their binding. This novel concept of enhancing sensitivity of immunoassay for DON based on nanobody may provide potential applications in a general method for immunoassay of various food chemical contaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation

    NARCIS (Netherlands)

    Dittmer, W.U.; Kievit, de P.; Prins, M.W.J.; Vissers, J.L.M.; Mersch, M.E.C.; Martens, M.F.W.C.

    2008-01-01

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions

  19. Factitious Graves' Disease Due to Biotin Immunoassay Interference-A Case and Review of the Literature.

    Science.gov (United States)

    Elston, Marianne S; Sehgal, Shekhar; Du Toit, Stephen; Yarndley, Tania; Conaglen, John V

    2016-09-01

    Biotin (vitamin B7) is an essential co-factor for four carboxylases involved in fatty acid metabolism, leucine degradation, and gluconeogenesis. The recommended daily intake (RDI) of biotin is approximately 30 μg per day. Low-moderate dose biotin is a common component of multivitamin preparations, and high-dose biotin (10 000 times RDI) has been reported to improve clinical outcomes and quality of life in patients with progressive multiple sclerosis. Biotin is also a component of immunoassays, and supplementation may cause interference in both thyroid and non-thyroid immunoassays. To assess whether biotin ingestion caused abnormal thyroid function tests (TFTs) in a patient through assay interference. We report a patient with biotin-associated abnormal TFTs and a systematic review of the literature. A tertiary endocrine service in Hamilton, New Zealand. The patient had markedly abnormal TFTs that did not match the clinical context. After biotin cessation, TFTs normalized far more rapidly than possible given the half-life of T4, consistent with assay interference by biotin. Multiple other analytes also tested abnormal in the presence of biotin. Biotin ingested in moderate to high doses can cause immunoassay interference. Depending on the assay format, biotin interference can result in either falsely high or low values. Interference is not limited to thyroid tests and has the potential to affect a wide range of analytes. It is important for clinicians to be aware of this interaction to prevent misdiagnosis and inappropriate treatment.

  20. On-Chip Immunoassay for Determination of Urinary Albumin

    Directory of Open Access Journals (Sweden)

    Adisorn Tuantranont

    2009-12-01

    Full Text Available An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane (PDMS microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993, with a detection limit of 0.81 mg L–1 (S/N = 3. The proposed system showed good precision, with relative standard deviations (RSDs of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10. Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15.

  1. On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Eom, Kyu Shik; Kim, Min Ho; Shim, Joon S

    2017-11-06

    In this work, a Lab-on-a-Chip (LOC) platform is used to electromagnetically actuate magnetic bead chains for an enhanced immunoassay. Custom-made electromagnets generate a magnetic field to form, rotate, lift and lower the magnetic bead chains (MBCs). The cost-effective, disposable LOC platform was made with a polymer substrate and an on-chip electrochemical sensor patterned via the screen-printing process. The movement of the MBCs is controlled to improve the electrochemical signal up to 230% when detecting beta-type human chorionic gonadotropin (β-hCG). Thus, the proposed on-chip MBC-based immunoassay is applicable for rapid, qualitative electrochemical point-of-care (POC) analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post

  3. Rapid Detection of Biological and Chemical Threat Agents Using Physical Chemistry, Active Detection, and Computational Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung; Dong, Li; Fu, Rong; Liotta, Lance; Narayanan, Aarthi; Petricoin, Emanuel; Ross, Mark; Russo, Paul; Zhou, Weidong; Luchini, Alessandra; Manes, Nathan; Chertow, Jessica; Han, Suhua; Kidd, Jessica; Senina, Svetlana; Groves, Stephanie

    2007-01-01

    Basic technologies have been successfully developed within this project: rapid collection of aerosols and a rapid ultra-sensitive immunoassay technique. Water-soluble, humidity-resistant polyacrylamide nano-filters were shown to (1) capture aerosol particles as small as 20 nm, (2) work in humid air and (3) completely liberate their captured particles in an aqueous solution compatible with the immunoassay technique. The immunoassay technology developed within this project combines electrophoretic capture with magnetic bead detection. It allows detection of as few as 150-600 analyte molecules or viruses in only three minutes, something no other known method can duplicate. The technology can be used in a variety of applications where speed of analysis and/or extremely low detection limits are of great importance: in rapid analysis of donor blood for hepatitis, HIV and other blood-borne infections in emergency blood transfusions, in trace analysis of pollutants, or in search of biomarkers in biological fluids. Combined in a single device, the water-soluble filter and ultra-sensitive immunoassay technique may solve the problem of early warning type detection of aerosolized pathogens. These two technologies are protected with five patent applications and are ready for commercialization.

  4. Tumor specific lung cancer diagnostics with multiplexed FRET immunoassays

    Science.gov (United States)

    Geißler, D.; Hill, D.; Löhmannsröben, H.-G.; Thomas, E.; Lavigne, A.; Darbouret, B.; Bois, E.; Charbonnière, L. J.; Ziessel, R. F.; Hildebrandt, N.

    2010-02-01

    An optical multiplexed homogeneous (liquid phase) immunoassay based on FRET from a terbium complex to eight different fluorescent dyes is presented. We achieved highly sensitive parallel detection of four different lung cancer specific tumor markers (CEA, NSE, SCC and CYFRA21-1) within a single assay and show a proof-of-principle for 5- fold multiplexing. The method is well suited for fast and low-cost miniaturized point-of-care testing as well as for highthroughput screening in a broad range of in-vitro diagnostic applications.

  5. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  6. High-sensitivity chemiluminescence immunoassays for detection of growth hormone doping in sports.

    Science.gov (United States)

    Bidlingmaier, Martin; Suhr, Jennifer; Ernst, Andrea; Wu, Zida; Keller, Alexandra; Strasburger, Christian J; Bergmann, Andreas

    2009-03-01

    Recombinant human growth hormone (rhGH) is abused in sports, but adequate routine doping tests are lacking. Analysis of serum hGH isoform composition has been shown to be effective in detecting rhGH doping. We developed and validated selective immunoassays for isoform analysis with potential utility for screening and confirmation in doping tests. Monoclonal antibodies with preference for pituitary hGH (phGH) or rhGH were used to establish 2 pairs of sandwich-type chemiluminescence assays with differential recognition of rhGH (recA and recB) and phGH (pitA and pitB). We analyzed specimens from volunteers before and after administration of rhGH and calculated ratios between the respective rec- and pit-assay results. Functional sensitivities were <0.05 microg/L, with intra- and interassay imprecision < or =8.4% and < or =13.7%, respectively. In 2 independent cohorts of healthy subjects, rec/pit ratios (median range) were 0.84 (0.09-1.32)/0.81 (0.27-1.21) (recA/pitA) and 0.68 (0.08-1.20)/0.80 (0.25-1.36) (recB/pitB), with no sex difference. In 20 recreational athletes, ratios (median SD) increased after a single injection of rhGH, reaching 350% (73%) (recA/pitA) and 400% (93%) (recB/pitB) of baseline ratios. At a moderate dose (0.033 mg/kg), mean recA/pitA and recB/pitB ratios remained significantly increased for 18 h (men) and 26 h (women). After high-dose rhGH (0.083 mg/kg), mean rec/pit ratios remained increased for 32 h (recA/pitA) and 34 h (recB/pitB) in men and were still increased after 36 h in women. Using sensitive chemiluminescence assays with preferential recognition of phGH or rhGH, detection of a single injection of rhGH was possible for up to 36 h.

  7. In-electrode vs. on-electrode: ultrasensitive Faraday cage-type electrochemiluminescence immunoassay.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Wang, Sui

    2016-03-28

    A new-concept of an "in-electrode" Faraday cage-type electrochemiluminescence immunoassay (ECLIA) method for the ultrasensitive detection of neurotensin (NT) was reported with capture antibody (Ab1)-nanoFe3O4@graphene (GO) and detector antibody (Ab2)&N-(4-aminobutyl)-N-ethylisoluminol (ABEI)@GO, which led to about 1000-fold improvement in sensitivity by extending the Helmholtz plane (OHP) of the proposed electrode assembly effectively.

  8. Silver Nanoparticle-Based Fluorescence-Quenching Lateral Flow Immunoassay for Sensitive Detection of Ochratoxin A in Grape Juice and Wine

    Science.gov (United States)

    Jiang, Hu; Li, Xiangmin; Xiong, Ying; Pei, Ke; Nie, Lijuan; Xiong, Yonghua

    2017-01-01

    A silver nanoparticle (AgNP)-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA) was developed for sensitive detection of ochratoxin A (OTA) in grape juice and wine samples in the present study. The Ru(phen)32+-doped silica nanoparticles (RuNPs) were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs. PMID:28264472

  9. Silver Nanoparticle-Based Fluorescence-Quenching Lateral Flow Immunoassay for Sensitive Detection of Ochratoxin A in Grape Juice and Wine

    Directory of Open Access Journals (Sweden)

    Hu Jiang

    2017-02-01

    Full Text Available A silver nanoparticle (AgNP-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA was developed for sensitive detection of ochratoxin A (OTA in grape juice and wine samples in the present study. The Ru(phen 3 2 + -doped silica nanoparticles (RuNPs were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs.

  10. Thermophilic Campylobacter spp. in turkey samples: evaluation of two automated enzyme immunoassays and conventional microbiological techniques

    DEFF Research Database (Denmark)

    Borck, Birgitte; Stryhn, H.; Ersboll, A.K.

    2002-01-01

    Aims: To determine the sensitivity and specificity of two automated enzyme immunoassays (EIA), EiaFoss and Minividas, and a conventional microbiological culture technique for detecting thermophilic Campylobacter spp. in turkey samples. Methods and Results: A total of 286 samples (faecal, meat...

  11. NiCoBP-doped carbon nanotube hybrid: A novel oxidase mimetic system for highly efficient electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bing; He, Yu; Liu, Bingqian; Tang, Dianping, E-mail: dianping.tang@fzu.edu.cn

    2014-12-03

    Highlights: • We report a new oxidase mimetic system for highly efficient electrochemical immunoassay. • NiCoBP-doped carbon nanotube hybrids were used as the nanocatalysts. • NiCoBP-doped carbon nanotube hybrids were used as the mimic oxidase. - Abstract: NiCoBP-doped multi-walled carbon nanotube (NiCoBP–MWCNT) was first synthesized by using induced electroless-plating method and functionalized with the biomolecules for highly efficient electrochemical immunoassay of prostate-specific antigen (PSA, used as a model analyte). We discovered that the as-synthesized NiCoBP–MWCNT had the ability to catalyze the glucose oxidization with a stable and well-defined redox peak. The catalytic current increased with the increment of the immobilized NiCoBP–MWCNT on the electrode. Transmission electron microscope (TEM) and energy dispersive X-ray spectrometry (EDX) were employed to characterize the as-prepared NiCoBP–MWCNT. Using the NiCoBP–MWCNT-conjugated anti-PSA antibody as the signal-transduction tag, a new enzyme-free electrochemical immunoassay protocol could be designed for the detection of target PSA on the capture antibody-functionalized immunosensing interface. Experimental results revealed that the designed immunoassay system could exhibit good electrochemical responses toward target PSA, and allowed the detection of PSA at a concentration as low as 0.035 ng mL{sup −1}. More importantly, the NiCoBP-MWCNT-based oxidase mimetic system could be further extended for the monitoring of other low-abundance proteins or disease-related biomarkers by tuning the target antibody.

  12. Recent advancements in the immunoassay domain

    International Nuclear Information System (INIS)

    Pradelles, Ph.

    1997-01-01

    The two types of immunoassay techniques, the competition analysis and the immuno-metric analysis (sandwich type), are described; the tracers used with theses methods have high specific radioactivity levels in order to be traced at extremely low content. Non radioactive tracers have been also developed, such as enzymatic, fluorescent, luminescent tracers, which are simpler and may be used at home. The Cea has recently developed some innovative immunoassay formats, such as acetylcholinesterase as a new enzymatic tracer, and immuno-metric dosage for very small molecules such as haptenes

  13. Development of a sensitive Luminex xMAP-based microsphere immunoassay for specific detection of Iris yellow spot virus.

    Science.gov (United States)

    Yu, Cui; Yang, Cuiyun; Song, Shaoyi; Yu, Zixiang; Zhou, Xueping; Wu, Jianxiang

    2018-04-04

    Iris yellow spot virus (IYSV) is an Orthotospovirus that infects most Allium species. Very few approaches for specific detection of IYSV from infected plants are available to date. We report the development of a high-sensitive Luminex xMAP-based microsphere immunoassay (MIA) for specific detection of IYSV. The nucleocapsid (N) gene of IYSV was cloned and expressed in Escherichia coli to produce the His-tagged recombinant N protein. A panel of monoclonal antibodies (MAbs) against IYSV was generated by immunizing the mice with recombinant N protein. Five specific MAbs (16D9, 11C6, 7F4, 12C10, and 14H12) were identified and used for developing the Luminex xMAP-based MIA systems along with a polyclonal antibody against IYSV. Comparative analyses of their sensitivity and specificity in detecting IYSV from infected tobacco leaves identified 7F4 as the best-performed MAb in MIA. We then optimized the working conditions of Luminex xMAP-based MIA in specific detection of IYSV from infected tobacco leaves by using appropriate blocking buffer and proper concentration of biotin-labeled antibodies as well as the suitable ratio between the antibodies and the streptavidin R-phycoerythrin (SA-RPE). Under the optimized conditions the Luminex xMAP-based MIA was able to specifically detect IYSV with much higher sensitivity than conventional enzyme-linked immunosorbent assay (ELISA). Importantly, the Luminex xMAP-based MIA is time-saving and the whole procedure could be completed within 2.5 h. We generated five specific MAbs against IYSV and developed the Luminex xMAP-based MIA method for specific detection of IYSV in plants. This assay provides a sensitive, high-specific, easy to perform and likely cost-effective approach for IYSV detection from infected plants, implicating potential broad usefulness of MIA in plant virus diagnosis.

  14. Review of the biochemical basis of enzyme immunoassays

    International Nuclear Information System (INIS)

    Klingler, W.

    1982-01-01

    The ever increasing number of radioimmunological determination poses problems allied with the handling of radioactive substances. In recent years various non-radioactive methods have been developed, among which the enzyme immunoassay is already in routine use. Homogeneous and heterogeneous enzyme immunoassays are described. Criteria for enzymes, substrates and enzyme-substrate reactions are listed. (orig.) [de

  15. [The efficiency of the enzyme immunoassay test system opisthorchiasis-CIC-EIA-best to detect circulating immune complexes containing opisthorchis antigens in the serum of patients with opisthorchiasis].

    Science.gov (United States)

    Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu

    2011-01-01

    The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.

  16. New generation of electrochemical immunoassay based on polymeric nanoparticles for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Mouffouk F

    2017-04-01

    Full Text Available Fouzi Mouffouk,1 Sihem Aouabdi,2 Entesar Al-Hetlani,1 Hacene Serrai,3 Tareq Alrefae,4 Liaohai Leo Chen5 1Department of Chemistry, Kuwait University, Safat, Kuwait; 2King Abdullah International Medical Research Center (KAIMRC, Jeddah, Kingdom of Saudi Arabia; 3Department of Radiology and Nuclear Medicine, University Hospital of Gent (UZG, Gent, Belgium; 4Department of Physics, Kuwait University, Safat, Kuwait; 5Surgical Precision Research Lab. Department of Surgery, University of Illinois at Chicago, IL, USA Abstract: Screening and early diagnosis are the key factors for the reduction of mortality rate and treatment cost of cancer. Therefore, sensitive and selective methods that can reveal the low abundance of cancer biomarkers in a biological sample are always desired. Here, we report the development of a novel electrochemical biosensor for early detection of breast cancer by using bioconjugated self-assembled pH-responsive polymeric micelles. The micelles were loaded with ferrocene molecules as “tracers” to specifically target cell surface-associated epithelial mucin (MUC1, a biomarker for breast and other solid carcinoma. The synthesis of target-specific, ferrocene-loaded polymeric micelles was confirmed, and the resulting sensor was capable of detecting the presence of MUC1 in a sample containing about 10 cells/mL. Such a high sensitivity was achieved by maximizing the loading capacity of ferrocene inside the polymeric micelles. Every single event of binding between the antibody and antigen was represented by the signal of hundreds of thousands of ferrocene molecules that were released from the polymeric micelles. This resulted in a significant increase in the intensity of the ferrocene signal detected by cyclic voltammetry. Keywords: electrochemical immunoassay, polymeric nanoparticles, breast cancer biomarkers, biosensors 

  17. Development and Validation of a Lateral Flow Immunoassay for Rapid Detection of NDM-Producing Enterobacteriaceae

    Science.gov (United States)

    Boutal, Hervé; Naas, Thierry; Devilliers, Karine; Oueslati, Saoussen; Bernabeu, Sandrine; Simon, Stéphanie

    2017-01-01

    ABSTRACT The global spread of carbapenemase-producing Enterobacteriaceae (CPE) that are often resistant to most, if not all, classes of antibiotics is a major public health concern. The NDM-1 carbapenemase is among the most worrisome carbapenemases given its rapid worldwide spread. We have developed and evaluated a lateral flow immunoassay (LFIA) (called the NDM LFIA) for the rapid and reliable detection of NDM-like carbapenemase-producing Enterobacteriaceae from culture colonies. We evaluated the NDM LFIA using 175 reference enterobacterial isolates with characterized β-lactamase gene content and 74 nonduplicate consecutive carbapenem-resistant clinical isolates referred for expertise to the French National Reference Center (NRC) for Antibiotic Resistance during a 1-week period (in June 2016). The reference collection included 55 non-carbapenemase producers and 120 carbapenemase producers, including 27 NDM producers. All 27 NDM-like carbapenemase producers of the reference collection were correctly detected in less than 15 min by the NDM LFIA, including 22 strains producing NDM-1, 2 producing NDM-4, 1 producing NDM-5, 1 producing NDM-7, and 1 producing NDM-9. All non-NDM-1 producers gave a negative result with the NDM LFIA. No cross-reaction was observed with carbapenemases (VIM, IMP, NDM, KPC, and OXA-48-like), extended-spectrum β-lactamases (ESBLs) (TEM, SHV, and CTX-M), AmpCs (CMY-2, DHA-2, and ACC-1), and oxacillinases (OXA-1, -2, -9, and -10). Similarly, among the 74 referred nonduplicate consecutive clinical isolates, all 7 NDM-like producers were identified. Overall, the sensitivity and specificity of the assay were 100% for NDM-like carbapenemase detection with strains cultured on agar. The NDM LFIA was efficient, rapid, and easy to implement in the routine workflow of a clinical microbiology laboratory for the confirmation of NDM-like carbapenemase-producing Enterobacteriaceae. PMID:28404680

  18. Vertical microreactor stack consist of poly-(tetrafluoroethylene) microfluidics for immunoassay

    International Nuclear Information System (INIS)

    Ukita, Yoshiaki; Kondo, Saki; Utsumi, Yuichi; Takeo, Masahiro; Negoro, Seiji; Kataoka, Chiwa

    2010-01-01

    This paper reports the first application of high-aspect ratio PTFE microstruscute, which fabricated by synchrotron radiation induced photo-evaporation process, to enzyme-linked immunosorvent assay. The advantages of PTFE microstructure for the development of lab-on-a-chip due to the extremely high-aspect ratio microstructure and chemical stability of PTFE is discussed. The results of immunoassay shows the successful detection of analyte (mouse IgG) with detection range with 0-100ng/ml. This result suggests the successful immobilization of antibody (anti-mouse IgG goat antibody) onto the x-ray exposed surface of PTFE microstructure and successful demonstration of antigen-antibody reaction in the PTFE high-aspect ratio microstructure. We also demonstrated the detection of polychlorinated biphenyl (PCB). As the result of demonstration, we successfully detected PCB with ranging analyte concentration of 0.1-10 ng/ml. (author)

  19. Development of an immunomagnetic bead-based time-resolved fluorescence immunoassay for rapid determination of levels of carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Hou Jingyuan; Liu Tiancai; Lin Guanfeng; Li Zhixiong; Zou Liping; Li Ming [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China); Wu Yingsong, E-mail: wg@fimmu.com [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China)

    2012-07-13

    Highlights: Black-Right-Pointing-Pointer Magnetic beads was used as the solid phase for TRFIA. Black-Right-Pointing-Pointer The linearity range was broadened greatly compared with conventional TRFIA method. Black-Right-Pointing-Pointer The analysis time was significantly shorter compared with conventional TRFIA method. Black-Right-Pointing-Pointer This method could be developed for practical clinical detections of tumor-associated antigens. - Abstract: A novel immunoassay for the determination of tumor markers in human serum was established by combining a time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a sandwich-type immunoassay format, analytes in samples were captured by magnetic beads coated with one monoclonal antibody and 'sandwiched' by another monoclonal antibody labeled with europium chelates. The immunocomplex was separated and washed by exposure to a magnetic field and treatment with enhancement solution; fluorescence was then measured according to the number of europium ions dissociated. Levels of the model analyte, carcinoembryonic antigen (CEA), were determined in a linear range (1-1000 ng mL{sup -1}) with a limit of detection of 0.5 ng mL{sup -1} under optimal conditions. The reproducibility, recovery, and specificity of the immunoassay were demonstrated to be acceptable. To evaluate this novel assay for clinical applications, 239 serum samples were evaluated. Compared with the conventional TRFIA and chemiluminescence immunoassay (CLIA), the correlation coefficients of the developed immunoassay were 0.985 and 0.975, respectively. These results showed good correlation and confirmed that our method is feasible and could be used for the clinical determination of CEA (or other tumor antigens) in human serum.

  20. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    OpenAIRE

    Ruzzenente, Orazio; Salvagno, Gian Luca; Gelati, Matteo; Lippi, Giuseppe

    2016-01-01

    Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and ...

  1. Reagent-loaded plastic microfluidic chips for detecting homocysteine

    International Nuclear Information System (INIS)

    Suk, Ji Won; Jang, Jae-Young; Cho, Jun-Hyeong

    2008-01-01

    This report describes the preliminary study on plastic microfluidic chips with pre-loaded reagents for detecting homocysteine (Hcy). All reagents needed in an Hcy immunoassay were included in a microfluidic chip to remove tedious assay steps. A simple and cost-effective bonding method was developed to realize reagent-loaded microfluidic chips. This technique uses an intermediate layer between two plastic substrates by selectively patterning polydimethylsiloxane (PDMS) on the embossed surface of microchannels and fixing the substrates under pressure. Using this bonding method, the competitive immunoassay for SAH, a converted form of Hcy, was performed without any damage to reagents in chips, and the results showed that the fluorescent signal from antibody antigen binding decreased as the SAH concentration increased. Based on the SAH immunoassay, whole immunoassay steps for Hcy detection were carried out in plastic microfluidic chips with all necessary reagents. These experiments demonstrated the feasibility of the Hcy immunoassay in microfluidic devices

  2. Structural basis for the high specificity of a Trypanosoma congolense immunoassay targeting glycosomal aldolase.

    Directory of Open Access Journals (Sweden)

    Joar Pinto

    2017-09-01

    Full Text Available Animal African trypanosomosis (AAT is a neglected tropical disease which imposes a heavy burden on the livestock industry in Sub-Saharan Africa. Its causative agents are Trypanosoma parasites, with T. congolense and T. vivax being responsible for the majority of the cases. Recently, we identified a Nanobody (Nb474 that was employed to develop a homologous sandwich ELISA targeting T. congolense fructose-1,6-bisphosphate aldolase (TcoALD. Despite the high sequence identity between trypanosomatid aldolases, the Nb474-based immunoassay is highly specific for T. congolense detection. The results presented in this paper yield insights into the molecular principles underlying the assay's high specificity.The structure of the Nb474-TcoALD complex was determined via X-ray crystallography. Together with analytical gel filtration, the structure reveals that a single TcoALD tetramer contains four binding sites for Nb474. Through a comparison with the crystal structures of two other trypanosomatid aldolases, TcoALD residues Ala77 and Leu106 were identified as hot spots for specificity. Via ELISA and surface plasmon resonance (SPR, we demonstrate that mutation of these residues does not abolish TcoALD recognition by Nb474, but does lead to a lack of detection in the Nb474-based homologous sandwich immunoassay.The results show that the high specificity of the Nb474-based immunoassay is not determined by the initial recognition event between Nb474 and TcoALD, but rather by its homologous sandwich design. This (i provides insights into the optimal set-up of the assay, (ii may be of great significance for field applications as it could explain the potential detection escape of certain T. congolense strains, and (iii may be of general interest to those developing similar assays.

  3. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  4. Chemiluminescence immunoassay for chloramphenicol

    International Nuclear Information System (INIS)

    Lin Si; Xu Wenge; Liu Yibing

    2007-06-01

    A simple, solid-phase chemiluminescence immunoassay (CLIA) for the measurement of Chloramphenicol(CAP) in foodstuffs is described. A rabbit anti-CAP IgG is passively adsorbed onto the walls of polypropylene plates. The labeled conjugant is horseradish peroxidase(HRP) conjugate of CAP. Luminol solution is used as the substrate of HRP. The light yield is inversely proportional to the concentration of CAP. The method has a similar sensitivity (0.05 ng/mL), specificity, precision, and accuracy to a conventional enzyme immunoassay (EIA). The intra-assay and inter-assay CVs of ten samples were <8 and <20%, respectively, and the analytical recovery of the method was 87% 100%. The experimental correlation coefficient of dilution was found to be 0.999 using milk supernatant as buffer. The assay range for the method was 0.1-10 ng/mL, and it displayed good linearity. (authors)

  5. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  6. The immunoassay handbook

    National Research Council Canada - National Science Library

    Wild, David (David G.)

    2001-01-01

    ... importantly, enabling them to keep current on the basic theory behind immunoassay. Since the publication of the previous edition in 1994, the field has continued to evolve rapidly, and the need for a fully updated version of this book is now paramount. The second edition has been comprehensively updated and new chapters have been added to each section" [publisher's web site].

  7. Simplified immunoassay for rapid Dengue serotype diagnosis, revealing insensitivity to non-specific binding interference

    Directory of Open Access Journals (Sweden)

    Fernanda C.C.L. Loureiro

    2017-04-01

    Full Text Available Proof of concept of an immunoassay, which is easy to implement, for rapid Dengue virus (DENV serotype diagnosis, in the early infection stage, is reported. The four-layer assay is immobilized onto a thin gold film and relies on a low cost, disposable polymer biochip for optical surface plasmon resonance sensing and detection. The protocol comprises Neutravidin-Biotin mediated monoclonal antibody (MAB attachment as the functionalized sensing element. Formation of the MAB-DENV complex results in a pronounced thickness change that is optically recorded in real time, employing a microfluidic set-up. Virus presence is confirmed by atomic force microscopy from the same sample. Serum samples were collected from a patient in acute febrile state. Simultaneous serological analysis by means of the reverse transcription polymerase chain reaction, independently, confirmed presence of DENV2 and DENV3. The protocol proved applicable in presence of strong non-specific binding interference that originates from, and is caused by, various blood, serum and other body fluid constituents. False positive indications for both, negative serum and blood control samples were not observed. The achievable limit of detection was estimated to be 2×104 particles/ml. Eventually, the method can be modified towards detection of other viruses by using the same protocol. Keywords: Immuno-assay, Dengue virus detection, Non-specific binding

  8. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  9. Simultaneous detection of IgG antibodies associated with viral hemorrhagic fever by a multiplexed Luminex-based immunoassay.

    Science.gov (United States)

    Wu, Wei; Zhang, Shuo; Qu, Jing; Zhang, Quanfu; Li, Chuan; Li, Jiandong; Jin, Cong; Liang, Mifang; Li, Dexin

    2014-07-17

    Viral hemorrhagic fevers (VHFs) are worldwide diseases caused by several kinds of viruses. With the emergence of new viruses, advanced diagnostic methods are urgently needed for identification of VHFs. Based on Luminex xMAP technology, a rapid, sensitive, multi-pathogen and high-throughput method which could simultaneously detect hemorrhagic fever viruses (HFVs) specific IgG antibodies was developed. Recombinant antigens of nine HFVs including Hantaan virus (HTNV), Seoul virus (SEOV), Puumala virus (PUUV), Andes virus (ANDV), Sin Nombre virus (SNV), Crimean-Congo hemorrhagic fever virus (CCHFV), Rift Valley fever virus (RVFV), Severe fever with thrombocytopenia syndrome bunyavirus (SFTSV) and dengue virus (DENV) were produced and purified from a prokaryotic expression system and the influence of the coupling amount was investigated. Cross-reactions among antigens and their rabbit immune sera were evaluated. Serum samples collected from 51 laboratory confirmed hemorrhagic fever with renal syndrome (HFRS) patients, 43 confirmed SFTS patients and 88 healthy donors were analyzed. Results showed that recombinant nucleocapsid protein of the five viruses belonging to the genus Hantavirus, had serological cross-reactivity with their corresponding rabbit immune sera, but not apparent with immune sera of other four viruses. Evaluation of this new method with clinical serum samples showed 98.04% diagnostic sensitivity for HFRS, 90.70% for SFTS detection and the specificity was ranging from 66.67% to 100.00%. The multiplexed Luminex-based immunoassay has firstly been established in our study, which provides a potentially reliable diagnostic tool for IgG antibody detection of VHFs. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    International Nuclear Information System (INIS)

    Lattanzio, Veronica M.T.; Nivarlet, Noan; Lippolis, Vincenzo; Gatta, Stefania Della; Huet, Anne-Catherine; Delahaut, Philippe; Granier, Benoit; Visconti, Angelo

    2012-01-01

    Highlights: ► We developed a rapid method based on a multiplex dipstick immunoassay. ► The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. ► We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin–BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73–109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC–MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins in cereals.

  11. An anti-phospholipase A2 receptor quantitative immunoassay and epitope analysis in membranous nephropathy reveals different antigenic domains of the receptor.

    Directory of Open Access Journals (Sweden)

    Astrid Behnert

    Full Text Available The phospholipase A2 receptor (PLA2R was recently discovered as a target autoantigen in patients with idiopathic membranous nephropathy (IMN. Published evidence suggests that the autoantibodies directed towards a conformation dependent epitope are currently effectively detected by a cell based assay (CBA utilizing indirect immunofluorescence (IIF on tissue culture cells transfected with the PLA2R cDNA. Limitations of such IIF-CBA assays include observer dependent subjective evaluation of semi-quantitative test results and the protocols are not amenable to high throughput diagnostic testing. We developed a quantitative, observer independent, high throughput capture immunoassay for detecting PLA2R autoantibodies on an addressable laser bead immunoassay (ALBIA platform. Since reactive domains of PLA2R (i.e. epitopes could be used to improve diagnostic tests by using small peptides in various high throughput diagnostic platforms, we identified PLA2R epitopes that bound autoantibodies of IMN patients. These studies confirmed that inter-molecular epitope spreading occurs in IMN but use of the cognate synthetic peptides in immunoassays was unable to conclusively distinguish between IMN patients and normal controls. However, combinations of these peptides were able to effectively absorb anti-PLA2R reactivity in IIF-CBA and an immunoassay that employed a lysate derived from HEK cells tranfected with and overexpressing PLA2R. While we provide evidence of intermolecular epitope spreading, our data indicates that in addition to conformational epitopes, human anti-PLA2R reactivity in a commercially available CBA and an addressable laser bead immunoassay is significantly absorbed by peptides representing epitopes of PLA2R.

  12. Trace-level mercury ion (Hg2+) analysis in aqueous sample based on solid-phase extraction followed by microfluidic immunoassay.

    Science.gov (United States)

    Date, Yasumoto; Aota, Arata; Terakado, Shingo; Sasaki, Kazuhiro; Matsumoto, Norio; Watanabe, Yoshitomo; Matsue, Tomokazu; Ohmura, Naoya

    2013-01-02

    Mercury is considered the most important heavy-metal pollutant, because of the likelihood of bioaccumulation and toxicity. Monitoring widespread ionic mercury (Hg(2+)) contamination requires high-throughput and cost-effective methods to screen large numbers of environmental samples. In this study, we developed a simple and sensitive analysis for Hg(2+) in environmental aqueous samples by combining a microfluidic immunoassay and solid-phase extraction (SPE). Using a microfluidic platform, an ultrasensitive Hg(2+) immunoassay, which yields results within only 10 min and with a lower detection limit (LOD) of 0.13 μg/L, was developed. To allow application of the developed immunoassay to actual environmental aqueous samples, we developed an ion-exchange resin (IER)-based SPE for selective Hg(2+) extraction from an ion mixture. When using optimized SPE conditions, followed by the microfluidic immunoassay, the LOD of the assay was 0.83 μg/L, which satisfied the guideline values for drinking water suggested by the United States Environmental Protection Agency (USEPA) (2 μg/L; total mercury), and the World Health Organisation (WHO) (6 μg/L; inorganic mercury). Actual water samples, including tap water, mineral water, and river water, which had been spiked with trace levels of Hg(2+), were well-analyzed by SPE, followed by microfluidic Hg(2+) immunoassay, and the results agreed with those obtained from reduction vaporizing-atomic adsorption spectroscopy.

  13. Enhanced Plasmonic Biosensors of Hybrid Gold Nanoparticle-Graphene Oxide-Based Label-Free Immunoassay

    Science.gov (United States)

    Chiu, Nan-Fu; Chen, Chi-Chu; Yang, Cheng-Du; Kao, Yu-Sheng; Wu, Wei-Ren

    2018-05-01

    In this study, we propose a modified gold nanoparticle-graphene oxide sheet (AuNP-GO) nanocomposite to detect two different interactions between proteins and hybrid nanocomposites for use in biomedical applications. GO sheets have high bioaffinity, which facilitates the attachment of biomolecules to carboxyl groups and has led to its use in the development of sensing mechanisms. When GO sheets are decorated with AuNPs, they introduce localized surface plasmon resonance (LSPR) in the resonance energy transfer of spectral changes. Our results suggest a promising future for AuNP-GO-based label-free immunoassays to detect disease biomarkers and rapidly diagnose infectious diseases. The results showed the detection of antiBSA in 10 ng/ml of hCG non-specific interfering protein with dynamic responses ranging from 1.45 nM to 145 fM, and a LOD of 145 fM. Considering the wide range of potential applications of GO sheets as a host material for a variety of nanoparticles, the approach developed here may be beneficial for the future integration of nanoparticles with GO nanosheets for blood sensing. The excellent anti-interference characteristics allow for the use of the biosensor in clinical analysis and point-of-care testing (POCT) diagnostics of rapid immunoassay products, and it may also be a potential tool for the measurement of biomarkers in human serum.

  14. DEMONSTRATION BULLETIN: PCP IMMUNOASSAY TECHNOLOGIES - PENTA RISC BY ENSYS INC., PENTA RAPID BY OHMICRON CORP., ENVIROGARD BY MILLIPORE

    Science.gov (United States)

    The objectives of this demonstration were to test these field screening technologies for accuracy and precision in detecting Pentachlorophenol (PCP) levels in soil and water by comparing their results with those of a confirmatory laboratory. The three immunoassay technologies ...

  15. Novel enzyme immunoassay system for simultaneous detection of six subclasses of antiphospholipid antibodies for differential diagnosis of antiphospholipid syndrome.

    Science.gov (United States)

    Nojima, Junzo; Motoki, Yukari; Hara, Kazusa; Sakata, Toshiyuki; Ichihara, Kiyoshi

    2017-06-01

    : Antiphospholipid syndrome, which often complicates systemic lupus erythematosus (SLE), features high occurrence of arterial and/or venous thrombosis and recurrent fetal loss. However, which antibody subclass contributes to which clinical event remains uncertain. We newly developed an up-to-date enzyme immunoassay system using the AcuStar automated analyzer (Instrumentation Laboratory, Bedford, Massachusetts, USA) for parallel detection of six subclasses of antiphospholipid antibodies (aPLs): anticardiolipin antibodies (aCL) of IgG, IgM, and IgA and anti-β2-glycoprotein I antibodies (aβ2GPI) of IgG, IgM, and IgA. They were measured in 276 healthy volunteers and 138 patients with SLE: 45 with thromboembolic complications (29 arterial; 16 venous) and 93 without. Lupus anticoagulant activity in their plasma was measured according to the guidelines recommended by the Subcommittee on Lupus Anticoagulant/Phospholipid-Dependent Antibodies. aCL/β2GPI was measured with a standard ELISA kit commonly used in Japan. The positive results of IgG aCL, IgA aCL, and IgG aβ2GPI were closely associated with thromboembolic complications, whereas IgM aCL and IgM aβ2GPI were not. receiver operating characteristic analysis revealed that the accuracy of predicting thromboembolic complications based on the composite test results of the former three antibodies were obviously higher than by each alone. Regarding agreement with the test results of lupus anticoagulant activity, IgG aβ2GPI showed the closest match. Patients with SLE frequently possess various combinations of the six aPL subclasses, and this antibody spectrum is closely associated with thromboembolic events in these patients. This new automated enzyme immunoassay system allows simultaneous analysis of the profile of aPL subclasses for the differential diagnosis of antiphospholipid antibody syndrome in its early stage.

  16. Intra- and inter-laboratory validation of a dipstick immunoassay for the detection of tropane alkaloids hyoscyamine and scopolamine in animal feed.

    Science.gov (United States)

    Mulder, Patrick P J; von Holst, Christoph; Nivarlet, Noan; van Egmond, Hans P

    2014-01-01

    Tropane alkaloids (TAs) are toxic secondary metabolites produced by plants of, inter alia, the genera Datura (thorn apple) and Atropa (deadly nightshade). The most relevant TAs are (-)-L-hyoscyamine and (-)-L-scopolamine, which act as antagonists of acetylcholine muscarinic receptors and can induce a variety of distinct toxic syndromes in mammals (anti-cholinergic poisoning). The European Union has regulated the presence of seeds of Datura sp. in animal feeds, specifying that the content should not exceed 1000 mg kg(-1) (Directive 2002/32/EC). For materials that have not been ground, visual screening methods are often used to comply with these regulations, but these cannot be used for ground materials and compound feeds. Immunological assays, preferably in dipstick format, can be a simple and cost-effective approach to monitor feedstuffs in an HACCP setting in control laboratories. So far no reports have been published on immunoassays that are capable of detecting both hyoscyamine and scopolamine with equal sensitivity and that can be used, preferably in dipstick format, for application as a fast screening tool in feed analysis. This study presents the results obtained for the in-house and inter-laboratory validation of a dipstick immunoassay for the detection of hyoscyamine and scopolamine in animal feed. The target level was set at 800 µg kg(-1) for the sum of both alkaloids. By using a representative set of compound feeds during validation and a robust study design, a reliable impression of the relevant characteristics of the assay could be obtained. The dipstick test displayed similar sensitivity towards the two alkaloids and it could be concluded that the test has a very low probability of producing a false-positive result at blank level or a false-negative result at target level. The assay can be used for monitoring of TAs in feedstuffs, but has also potential as a quick screening tool in food- or feed-related poisonings.

  17. Effective gasoline site assessment using the D TECH trademark BTEX immunoassay

    International Nuclear Information System (INIS)

    Hudak, R.T.; Melby, J.M.; Stave, J.W.

    1994-01-01

    The application of immunoassay to environmental testing can greatly aid in assessing sites for various contaminants including PCB, TNT, RDX, PAH and BTEX. Immunoassay offers several benefits to site assessment: it is accurate, reproducible and relatively inexpensive compared to instrumental analysis. In addition, because of its ease-of-use, this technique is ideal for the field and requires minimal user training. To demonstrate not only the effectiveness of the BTEX immunoassay, but also the reliability of the field results, a gasoline contaminated site was assessed comparing the BTEX immunoassay to gas chromatography. All sampling and site related activities were executed in accordance to the USEPA SW-846 guidelines. Three (3) analyses were performed on each sample. One immunoassay analysis was performed in the field by an individual who received two (2) hours of training prior to the start of the study. A technician familiar with the immunoassay ran the second analysis in a laboratory. Finally, an independent GC laboratory certified for BTEX method 8020 and 602 performed the GC analyses. One hundred one (101) samples were analyzed: thirty-nine (39) samples were water, the other sixty-two (62) were soils ranging from clay to silt. The results and costs of the methods are compared

  18. Competitive enzyme immunoassay for human chorionic somatomammotropin using the avidin-biotin system

    International Nuclear Information System (INIS)

    Rappuoli, R.; Leoncini, P.; Tarli, P.; Neri, P.

    1981-01-01

    Human chorionic somatomammotropin (HCS) is determined by an enzyme immunoassay where HCS competes with biotin-labeled HCS for insolubilized anti-HCS antibodies. Enzyme-labeled avidin is then used to reveal the amount of bound HCS. The system proves to be sensitive (1 ng/ml of HCS can be detected) and results agree with radioimmunoassay determinations (correlation coefficient = 0.979). Kinetics of the avidin-biotin reaction and coating of polystyrene wells are also investigated

  19. Detection of virus-specific intrathecally synthesised immunoglobulin G with a fully automated enzyme immunoassay system

    Directory of Open Access Journals (Sweden)

    Weissbrich Benedikt

    2007-05-01

    Full Text Available Abstract Background The determination of virus-specific immunoglobulin G (IgG antibodies in cerebrospinal fluid (CSF is useful for the diagnosis of virus associated diseases of the central nervous system (CNS and for the detection of a polyspecific intrathecal immune response in patients with multiple sclerosis. Quantification of virus-specific IgG in the CSF is frequently performed by calculation of a virus-specific antibody index (AI. Determination of the AI is a demanding and labour-intensive technique and therefore automation is desirable. We evaluated the precision and the diagnostic value of a fully automated enzyme immunoassay for the detection of virus-specific IgG in serum and CSF using the analyser BEP2000 (Dade Behring. Methods The AI for measles, rubella, varicella-zoster, and herpes simplex virus IgG was determined from pairs of serum and CSF samples of patients with viral CNS infections, multiple sclerosis and of control patients. CSF and serum samples were tested simultaneously with reference to a standard curve. Starting dilutions were 1:6 and 1:36 for CSF and 1:1386 and 1:8316 for serum samples. Results The interassay coefficient of variation was below 10% for all parameters tested. There was good agreement between AIs obtained with the BEP2000 and AIs derived from the semi-automated reference method. Conclusion Determination of virus-specific IgG in serum-CSF-pairs for calculation of AI has been successfully automated on the BEP2000. Current limitations of the assay layout imposed by the analyser software should be solved in future versions to offer more convenience in comparison to manual or semi-automated methods.

  20. Redox-Magnetohydrodynamic Microfluidics Without Channels and Compatible with Electrochemical Detection Under Immunoassay Conditions

    Science.gov (United States)

    Weston, Melissa C.; Nash, Christena K.; Fritsch, Ingrid

    2010-01-01

    A unique capability of redox-magnetohydrodynamics (redox-MHD) for handling liquids on a small scale was demonstrated. A 1.2-μL solution plug was pumped from an injection site to a detector without the need for a channel to direct the flow. The redox pumping species did not interfere with enzymatic activity in a solution compatible with enzyme-linked immunoassays. Alkaline phosphatase (AP), a common enzyme label, converted p-aminophenyl phosphate (PAPP) to p-aminophenol (PAPR) in the presence of 2.5 mM Ru(NH3)6Cl2 and 2.5 mM Ru(NH3)6 Cl3, in 0.1 M Tris buffer (pH=9). A solution plug containing PAPP (no AP) was pumped through the surrounding solution containing AP (no PAPP), and the enzymatically-generated PAPR was easily detected and distinguishable electrochemically from the pumping species with square wave voltammetry down to 0.1 mM concentrations. The test device consisted of a silicon chip containing individually-addressable microband electrodes, placed on a 0.5-T NdFeB permanent magnet with the field oriented perpendicular to the chip. A 8.0-mm wide × 15.5-mm long × 1.5-mm high volume of solution was contained by a poly(dimethylsiloxane) gasket and capped with a glass slide. A steady-state fluid velocity of ~30 μm/s was generated in a reinforcing flow configuration between oppositely polarized sets of pumping electrodes with ~2.1 μA. PMID:20681513

  1. Europium(III) chelate-dyed nanoparticles as donors in a homogeneous proximity-based immunoassay for estradiol

    International Nuclear Information System (INIS)

    Kokko, Leena; Sandberg, Kaisa; Loevgren, Timo; Soukka, Tero

    2004-01-01

    Nanoparticles containing thousands of fluorescent europium(III) chelates have a very high specific activity compared to traditional lanthanide chelate labels. It can be assumed that if these particles are used in a homogeneous assay as donors, multiple chelates can excite a single acceptor in turns and the energy transfer to the acceptor is increased. The principle was employed in an immunoassay using luminescent resonance energy transfer from a long lifetime europium(III) chelate-dyed nanoparticle to a short lifetime, near-infrared fluorescent molecule. Due to energy transfer fluorescence lifetime of the sensitised emission was prolonged and fluorescence could be measured using a time-resolved detection. A competitive homogeneous immunoassay for estradiol was created using 92 nm europium(III) chelate-dyed nanoparticle coated with 17β-estradiol specific recombinant antibody Fab fragments as a donor and estradiol conjugated with near-infrared dye AlexaFluor 680 as an acceptor. The density of Fab fragments on the surface of the particle influenced the sensitivity of the immunoassay. The optimal Fab density was reached when the entire surface of the particle participated in the energy transfer, but the areas where the energy was transferred to a single acceptor, did not overlap. We were able to detect estradiol concentrations down to 70 pmol l -1 (3xSD of a standard containing 0 nmol l -1 of E2) using a 96-well platform. In this study we demonstrated that nanoparticles containing lanthanide chelates could be used as efficient donors in homogeneous assays

  2. Magnetophoretic separation ICP-MS immunoassay using Cs-doped multicore magnetic nanoparticles for the determination of salmonella typhimurium.

    Science.gov (United States)

    Jeong, Arong; Lim, H B

    2018-02-01

    In this work, a magnetophoretic separation ICP-MS immunoassay using newly synthesized multicore magnetic nanoparticles (MMNPs) was developed for the determination of salmonella typhimurium (typhi). The uniqueness of this method was the use of MMNPs doped with Cs for both separation and detection, which enable us to achieve fast analysis, high sensitivity, and good reliability. For demonstration, heat-killed typhi in a phosphate buffer solution was determined by ICP-MS after the MMNP-typhi reaction product was separated from unreacted MMNPs in a micropipette tip filled with 25% polyethylene glycol through magnetophoretic separation. The calibration curve obtained by plotting 133 Cs intensity vs. the number of synthetic standard, showed a coefficient of determination (R 2 ) of 0.94 with a limit of detection (LOD) of 102 cells/mL without cell culturing. Excellent recoveries, between 98-100%, were obtained from four replicates and compared with a sandwich-type ICP-MS immunoassay for further confirmation. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A sulfhydryl-reactive ruthenium (II complex and its conjugation to protein G as a universal reagent for fluorescent immunoassays.

    Directory of Open Access Journals (Sweden)

    Jing-Tang Lin

    Full Text Available To develop a fluorescent ruthenium complex for biosensing, we synthesized a novel sulfhydryl-reactive compound, 4-bromophenanthroline bis-2,2'-dipyridine Ruthenium bis (hexafluorophosphate. The synthesized Ru(II complex was crosslinked with thiol-modified protein G to form a universal reagent for fluorescent immunoassays. The resulting Ru(II-protein G conjugates were identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE. The emission peak wavelength of the Ru(II-protein G conjugate was 602 nm at the excitation of 452 nm which is similar to the spectra of the Ru(II complex, indicating that Ru(II-protein G conjugates still remain the same fluorescence after conjugation. To test the usefulness of the conjugate for biosensing, immunoglobulin G (IgG binding assay was conducted. The result showed that Ru(II-protein G conjugates were capable of binding IgG and the more cross-linkers to modify protein G, the higher conjugation efficiency. To demonstrate the feasibility of Ru(II-protein G conjugates for fluorescent immunoassays, the detection of recombinant histidine-tagged protein using the conjugates and anti-histidine antibody was developed. The results showed that the histidine-tagged protein was successfully detected with dose-response, indicating that Ru(II-protein G conjugate is a useful universal fluorescent reagent for quantitative immunoassays.

  4. New antibody and immunoassay pretreatment strategy to screen polychlorinated biphenyls in Korean transformer oil.

    Science.gov (United States)

    Terakado, Shingo; Ohmura, Naoya; Park, Seok-Un; Lee, Seung-Min; Glass, Thomas R

    2013-01-01

    Development and modifications are described that expand the application of an immunoassay from the detection of Kanechlors (Japanese technical PCBs mixtures) to the detection of Aroclors (U. S. technical PCB mixtures, used in Korea) in contaminated Korean transformer oil. The first necessary modification was the development of a new antibody with a reactivity profile favorable for Aroclors. The second modification was the addition of a second column to the solid-phase extraction method to reduce assay interference caused by the Korean oil matrix. The matrix interference is suspected to be caused by the presence of synthetic oils (or similar materials) present as contaminants. The modified assay was validated by comparison to high-resolution gas chromatography/high-resolution mass spectrometry analysis, and was shown to be tolerant of up to 10% of several common synthetic insulating oils. Finally the screening performance of the modified assay was evaluated using 500 used transformer oil samples of Korean origin, and was shown to have good performance in terms of false positive and false negative rates. This report provides evidence for the first establishment of immunoassay screening for Aroclor based PCB contamination in Korean transformer oil.

  5. Time-Resolved Fluorescence Immunoassay for C-Reactive Protein Using Colloidal Semiconducting Nanoparticles

    Directory of Open Access Journals (Sweden)

    Pekka Hänninen

    2011-11-01

    Full Text Available Besides the typical short-lived fluorescence with decay times in the nanosecond range, colloidal II/VI semiconductor nanoparticles dispersed in buffer also possess a long-lived fluorescence component with decay times in the microsecond range. Here, the signal intensity of the long-lived luminescence at microsecond range is shown to increase 1,000-fold for CdTe nanoparticles in PBS buffer. This long-lived fluorescence can be conveniently employed for time-gated fluorescence detection, which allows for improved signal-to-noise ratio and thus the use of low concentrations of nanoparticles. The detection principle is demonstrated with a time-resolved fluorescence immunoassay for the detection of C-reactive protein (CRP using CdSe-ZnS nanoparticles and green light excitation.

  6. Rational design of Raman-labeled nanoparticles for a dual-modality, light scattering immunoassay on a polystyrene substrate.

    Science.gov (United States)

    Israelsen, Nathan D; Wooley, Donald; Hanson, Cynthia; Vargis, Elizabeth

    2016-01-01

    Surface-enhanced Raman scattering (SERS) is a powerful light scattering technique that can be used for sensitive immunoassay development and cell labeling. A major obstacle to using SERS is the complexity of fabricating SERS probes since they require nanoscale characterization and optical uniformity. The light scattering response of SERS probes may also be modulated by the substrate used for SERS analysis. A typical SERS substrate such as quartz can be expensive. Polystyrene is a cheaper substrate option but can decrease the SERS response due to interfering Raman emission peaks and high background fluorescence. The goal of this research is to develop an optimized process for fabricating Raman-labeled nanoparticles for a SERS-based immunoassay on a polystyrene substrate. We have developed a method for fabricating SERS nanoparticle probes for use in a light scattering immunoassay on a polystyrene substrate. The light scattering profile of both spherical gold nanoparticle and gold nanorod SERS probes were characterized using Raman spectroscopy and optical absorbance spectroscopy. The effects of substrate interference and autofluorescence were reduced by selecting a Raman reporter with a strong light scattering response in a spectral region where interfering substrate emission peaks are minimized. Both spherical gold nanoparticles and gold nanorods SERS probes used in the immunoassay were detected at labeling concentrations in the low pM range. This analytical sensitivity falls within the typical dynamic range for direct labeling of cell-surface biomarkers using SERS probes. SERS nanoparticle probes were fabricated to produce a strong light scattering signal despite substrate interference. The optical extinction and inelastic light scattering of these probes was detected by optical absorbance spectroscopy and Raman spectroscopy, respectively. This immunoassay demonstrates the feasibility of analyzing strongly enhanced Raman signals on polystyrene, which is an

  7. Radio-immunoassay of plasma arginine vasopressin in man. Comparison of two methods of extraction

    International Nuclear Information System (INIS)

    Wolf, J.P.; Dumoulin, G.; Henriet, M.T.; Baulay, A.; Berthelay, S.

    1987-01-01

    Two methods of extraction, prior to radio-immunoassay (RIA) of human plasma arginine vasopressin (AVP) were tested: ethanol extraction (ETH), chromatography with ODS-Silice (ODS-Sil). Recovery of 125 I AVP was higher when using ODS-Sil than when using ETH. Recovery of standard AVP was found to be more efficient and reproducible for ODS-Sil. However, the RIA used, performed after chromatography with ODS-Sil, is not enough sensitive to detect low concentrations but is able to detect high concentrations and physiological variations of plasma AVP [fr

  8. Phage-Mediated Competitive Chemiluminescent Immunoassay for Detecting Cry1Ab Toxin by Using an Anti-Idiotypic Camel Nanobody.

    Science.gov (United States)

    Qiu, Yulou; Li, Pan; Dong, Sa; Zhang, Xiaoshuai; Yang, Qianru; Wang, Yulong; Ge, Jing; Hammock, Bruce D; Zhang, Cunzheng; Liu, Xianjin

    2018-01-31

    Cry toxins have been widely used in genetically modified organisms for pest control, raising public concern regarding their effects on the natural environment and food safety. In this work, a phage-mediated competitive chemiluminescent immunoassay (c-CLIA) was developed for determination of Cry1Ab toxin using anti-idiotypic camel nanobodies. By extracting RNA from camels' peripheral blood lymphocytes, a naive phage-displayed nanobody library was established. Using anti-Cry1Ab toxin monoclonal antibodies (mAbs) against the library for anti-idiotypic antibody screening, four anti-idiotypic nanobodies were selected and confirmed to be specific for anti-Cry1Ab mAb binding. Thereafter, a c-CLIA was developed for detection of Cry1Ab toxin based on anti-idiotypic camel nanobodies and employed for sample testing. The results revealed a half-inhibition concentration of developed assay to be 42.68 ± 2.54 ng/mL, in the linear range of 10.49-307.1 ng/mL. The established method is highly specific for Cry1Ab recognition, with negligible cross-reactivity for other Cry toxins. For spiked cereal samples, the recoveries of Cry1Ab toxin ranged from 77.4% to 127%, with coefficient of variation of less than 9%. This study demonstrated that the competitive format based on phage-displayed anti-idiotypic nanobodies can provide an alternative strategy for Cry toxin detection.

  9. Establishment of a novel immunoassay system for rapid detection of 2,4-dichlorophenoxyacetic acid residues based on magnetic-fluorescent probes

    Directory of Open Access Journals (Sweden)

    WANG Yuanfeng

    2014-12-01

    Full Text Available A novel immunoassay system based on magnetic-fluorescent probes was established to detect 2.4-dichlorophenoxyacetic acid (2,4-D residue in liquid system in food and agricultural products.The composites of anti-2,4-D antibody bound to Fe3O4@SiO2-NH2 was employed as the solid phase as well as magnetic probe.The composites composed of 2,4-D-OVA labeled with CdTe@SiO2-NH2 as the fluorescent probe was used to produce fluorescent signal.2,4-D and its fluorescent probe competed binding the antibody on the surface of the magnetic probe.The optimization of 2,4-D-OVA dosage,coupling PH and reaction time in preparing the fluorescent probe were investigated.It showed that in the synthesis of fluorescent probe 8.2 was the optimal pH,70 min was the optimal coupling time,500 μL amount of 2,4-D-OVA.The standard curve was obtained with the concentration of 2,4-D and the maximum fluorescence intensity.The detection limit of the assay was gotten and it was 3.55×10-8.One reaction step and one washing step were needed.The assay significantly shortened the testing time and amplified the detection signal compared with classic ELISA.

  10. A polyclonal antibody based immunoassay detects seven subtypes of Shiga toxin 2 produced by Escherichia coli in human and environmental samples.

    Directory of Open Access Journals (Sweden)

    Xiaohua He

    Full Text Available BACKGROUND: Shiga toxin-producing Escherichia coli (STEC are frequent causes of severe human diseases ranging from diarrhea to hemolytic uremic syndrome. The existing strategy for detection of STEC relies on the unique sorbitol-negative fermentation property of the O157 strains, the most commonly identified serotype has been E. coli O157. It is becoming increasingly evident, however, that numerous non-O157 STEC serotypes also cause outbreaks and severe illnesses. It is necessary to have new methods that are capable of detecting all STEC strains. METHODS AND FINDINGS: Here we describe the development of a sandwich ELISA assay for detecting both O157 and non-O157 STECs by incorporating a novel polyclonal antibody (pAb against Stx2. The newly established immunoassay was capable of detecting Stx2a spiked in environmental samples with a limit of detection between 10 and 100 pg/mL in soil and between 100 and 500 pg/mL in feces. When applied to 36 bacterial strains isolated from human and environmental samples, this assay detected Stx2 in all strains that were confirmed to be stx2-positive by real-time PCR, demonstrating a 100% sensitivity and specificity. CONCLUSIONS: The sandwich ELISA developed in this study will enable any competent laboratory to identify and characterize Stx2-producing O157 and non-O157 strains in human and environmental samples, resulting in rapid diagnosis and patient care. The results of epitope mapping from this study will be useful for further development of a peptide-based antibody and vaccine.

  11. Summary of field trials using the direct and competitive enzyme immunoassays for detection of antibody to brucella abortus

    International Nuclear Information System (INIS)

    Nielsen, K.; Gall, D.

    1998-01-01

    Two indirect and two competitive enzyme immunoassays for detection of antibody to Brucella abortus, validated elsewhere, were field tested in five different Latin American laboratories. Testing was performed according to standardised protocols using sera obtained in each area. Sera from B. abortus infected herds, from vaccinated (but serologically negative in a screening test) and non-vaccinated cattle were tested in each assay and compared to the results obtained with conventional diagnostic tests used for diagnosis of brucellosis in each country. Relative sensitivity and specificity values were calculated for each country as well as a weighted summary combining the data from all the participating laboratories. The result demonstrate that all ELISAs performed as well as, or better than, the conventional aerological tests. Given the inherent errors in the use of the latter in the diagnosis of brucellosis, it is recommended that the ELISAs described here be considered as replacements for the conventional tests. The CELISA using the lipopolysaccharide antigen with the competing monoclonal antibody M84, should be considered as the most useful because of cross-species and vaccination considerations. (author)

  12. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  13. Detecting Life and Biology-Related Parameters on Mars

    Science.gov (United States)

    Levin, Gilbet V.; Miller, Joseph D.; Straat, Patricia A.; Lodder, Robert; Hoover, Richard B.

    2007-01-01

    An integrated, miniaturized, low-power instrument capable of the detection and early characterization of microbial life in the soil of Mars is proposed. Based on the detection apd monitoring of on-going metabolism as being the surest evidence for extant life, the experiments will probe for chirality in metabolism, for circadian rhythm, and for photosynthesis. However, the instrument package will also be able to detect biosignatures and a variety of other physical and chemical parameters of the Martian surface that have significance for life. These include the presence and the physical state of water, the existence of an oxidant, the pH and the penetrability of the soil. Using the legacy of the 1976 Viking Labeled Release (LR) life detection experiment in conjunction with state-of-the-art laser diode spectral analysis, the instrument can be flown stand-alone, with or without a rover, or as part of an MSL-type mission. Sterility for experiment integrity and for planetary protection is provided.

  14. Hapten design and indirect competitive immunoassay for parathion determination: Correlation with molecular modeling and principal component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yihua [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Jin Maojun [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Gui Wenjun [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Cheng Jingli [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Guo Yirong [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Zhu Guonian [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China)]. E-mail: zhugn@zju.edu.cn

    2007-05-22

    A novel procedure for parathion hapten design is described. The optimal antigen for parathion was selected after molecular modeling studies of six types of potentially immunizing haptens with the aim to identify the best mimicking target analyte. Heterologous competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed after screening a battery of competitors as coating antigens. The relationship between the heterology degree of the competitor and the resulting immunoassay detectability was investigated according to the electronic similarities of the competitor haptens and the target analyte. Molecular modeling and principal component analysis were performed to understand the electronic distribution and steric parameters of the haptens at their minimum energetic levels. The results suggested that the competitors should have a high heterology to produce assays with good detectability values. An indirect competitive ELISA was finally selected for further investigation. The immunoassay had an IC{sub 50} value of 4.79 ng mL{sup -1} and a limit of detection of 0.31 ng mL{sup -1}. There was little or no cross-reactivity to similar compounds tested except for the insecticide parathion-methyl, which showed a cross-reactivity of 7.8%.

  15. Control of (pre-analytical aspects in immunoassay measurements of metabolic hormones in rodents

    Directory of Open Access Journals (Sweden)

    Maximilian Bielohuby

    2018-04-01

    Full Text Available The measurement of circulating hormones by immunoassay remains a cornerstone in preclinical endocrine research. For scientists conducting and interpreting immunoassay measurements of rodent samples, the paramount aim usually is to obtain reliable and meaningful measurement data in order to draw conclusions on biological processes. However, the biological variability between samples is not the only variable affecting the readout of an immunoassay measurement and a considerable amount of unwanted or unintended variability can be quickly introduced during the pre-analytical and analytical phase. This review aims to increase the awareness for the factors ‘pre-analytical’ and ‘analytical’ variability particularly in the context of immunoassay measurement of circulating metabolic hormones in rodent samples. In addition, guidance is provided how to gain control over these variables and how to avoid common pitfalls associated with sample collection, processing, storage and measurement. Furthermore, recommendations are given on how to perform a basic validation of novel single and multiplex immunoassays for the measurement of metabolic hormones in rodents. Finally, practical examples from immunoassay measurements of plasma insulin in mice address the factors ‘sampling site and inhalation anesthesia’ as frequent sources of introducing an unwanted variability during the pre-analytical phase. The knowledge about the influence of both types of variability on the immunoassay measurement of circulating hormones as well as strategies to control these variables are crucial, on the one hand, for planning and realization of metabolic rodent studies and, on the other hand, for the generation and interpretation of meaningful immunoassay data from rodent samples.

  16. Evaluation of the FIDIS vasculitis multiplex immunoassay for diagnosis and follow-up of ANCA-associated vasculitis and Goodpasture's disease

    NARCIS (Netherlands)

    Damoiseaux, J.; Vaessen, M.; Knapen, Y.; Csernok, E.; Stegeman, C. A.; Van Paassen, P.; Tervaert, J. W. Cohen; Gershwin, ME; Shoenfeld, Y

    2007-01-01

    We have evaluated a new-multiplex immunoassay (FIDIS Vasculitis) for simultaneous detection and quantification of anti-MPO, -PR3, and -glomerular basement membrane (GBM) antibodies in diagnosis and follow-up of ANCA-associated vasculitides (AAV) and Goodpasture's disease. ANCA were determined in

  17. Horseradish peroxidase and antibody labeled gold nanoparticle probe for amplified immunoassay of ciguatoxin in fish samples based on capillary electrophoresis with electrochemical detection.

    Science.gov (United States)

    Zhang, Zhaoxiang; Liu, Ying; Zhang, Chaoying; Luan, Wenxiu

    2015-03-01

    This paper describes a new amplified immunoassay with horseradish peroxidase (HRP) and antibody (Ab) labeled gold nanoparticles (AuNPs) probe hyphenated to capillary electrophoresis (CE) with electrochemical (EC) detection for ultrasensitive determination of ciguatoxin CTX1B. AuNPs were conjugated with HRP and Ab, and then incubated with limited amount of CTX1B to produce immunocomplex. The immunoreactive sample was injected into capillary for CE separation and EC detection. Enhanced sensitivity was obtained by adopting the AuNPs as carriers of HRP and Ab at high HRP/Ab molar ratio. The calibration curve of CTX1B was in the range of 0.06-90 ng/mL. The detection limit was 0.045 ng/mL, which is 38-fold lower than that of HPLC-MS method for CTX1B analysis. The proposed method was successfully applied for the quantification of CTX1B in contamined fish samples by simultaneously labeling Ab and HRP on AuNPs. The amplified IA with HRP and Ab labeled AuNPs probe hyphenated to CE and EC detection provides a sensitive analytical approach for the determination of trace ciguatoxin in complex samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    Energy Technology Data Exchange (ETDEWEB)

    Lattanzio, Veronica M.T., E-mail: veronica.lattanzio@ispa.cnr.it [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Nivarlet, Noan [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Lippolis, Vincenzo; Gatta, Stefania Della [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Huet, Anne-Catherine; Delahaut, Philippe [Centre d' Economie Rurale (CER Groupe), Rue du Point du Jour no 8, B-6900 Marloie (Belgium); Granier, Benoit [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Visconti, Angelo [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy)

    2012-03-09

    Highlights: Black-Right-Pointing-Pointer We developed a rapid method based on a multiplex dipstick immunoassay. Black-Right-Pointing-Pointer The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. Black-Right-Pointing-Pointer We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin-BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73-109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC-MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins

  19. Increasing of sensitivity of fluorescent immunoassay analysis of alpha-fetoprotein by means of plasmonical silver nanoparticles

    International Nuclear Information System (INIS)

    Vashchenko, S.V.; Min'ko, A.A.; Romanenko, A.A.; Gaponenko, S.V.; Kulakovich, O.S.

    2014-01-01

    A test system is proposed based on metal enhanced fluorescence to analyze low concentrations of alpha-fetoprotein (AFP), a tumor marker. Antigen-antibody reaction was performed on polystyrene plates coated with silver nanoparticles to increase sensitivity of fluorescent immunoassay and signal-to-noise ratio as compared to silver-free system. As compared to widely used ELISA technique and other immunoassay techniques the proposed approach is characterized by smaller probe volume, fast analysis and simplicity. The proposed test system uses layer-by-layer assembly approach, LED excitation and nanowatt photodetection set-up. The proposed test system offers AFP detection at concentrations used in clinical practice. Fluorescence enhancement for labeled AFP antibodies on a silver substrate was found to depend on antibodies concentration and was up to 6 times. (authors)

  20. Functionalized gold nanorod-based labels for amplified electrochemical immunoassay of E. coli as indicator bacteria relevant to the quality of dairy product.

    Science.gov (United States)

    Zhang, Xinai; Zhang, Fan; Zhang, Hongyin; Shen, Jianzhong; Han, En; Dong, Xiaoya

    2015-01-01

    In this paper, we report an amplified electrochemical immunoassay for Escherichia coli as indicator bacteria relevant to the quality of dairy product using the functionalized gold nanorod-based labels ({dAb-AuNR-FCA}). The {dAb-AuNR-FCA} labels were designed by exploiting silica-functionalized gold nanorods (AuNR@SiO2) as the carriers for immobilization of detection antibody (dAb) and ferrocenecarboxylic acid (FCA), in which dAb was used for recognition of E. coli and FCA tags served as signal-generating molecule. Greatly amplified signal was achieved in the sandwich-type immunoassay when enormous FCA linked to AuNR@SiO2. Compared with the commercially available {dAb-FCA}, the {dAb-AuNR-FCA} labels exhibited a better performance for E. coli assay due to the advantages of AuNR@SiO2 as carriers. Under optimal experimental conditions, it showed a linear relationship between the peak current of FCA and the logarithmic value of E. coli concentration ranging from 1.0×10(2) to 5.0×10(4) cfu mL(-1) with a detection limit of 60 cfu mL(-1) (S/N=3), and the electrochemical detection of E. coli could be achieved in 3h. Moreover, the proposed strategy was used to determine E. coli in dairy product (pure fresh milk, yogurt in shelf-life, and expired yogurt), and the recoveries of standard additions were in the range of 95.1-106%. This proposed strategy exhibited rapid response, high sensitivity and specificity for E. coli assay in dairy product, and could become a promising technique to estimate the quality of dairy product. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W.

    Science.gov (United States)

    Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung

    2018-01-01

    Using compound W (a 3,3'-diiodothyronine sulfate [T 2 S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Photosensitive particles (donor beads) coated with compound W or T 2 S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero.

  2. An ultrasensitive chemiluminescence immunoassay for fumonisin B1 detection in cereals based on gold-coated magnetic nanoparticles.

    Science.gov (United States)

    Jie, Mingsha; Yu, Songcheng; Yu, Fei; Liu, Lie; He, Leiliang; Li, Yanqiang; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B; Wu, Yongjun

    2018-07-01

    In the present study, a novel highly sensitive magnetic enzyme chemiluminescence immunoassay (MECLIA) was developed to detect fumonisin B 1 (FB 1 ) in cereal samples. The gold-coated magnetic nanoparticles (Fe 3 O 4 @Au, GoldMag) were used as solid phase carrier to develop a competitive CLIA for detecting FB 1 , in which FB 1 in samples would compete with FB 1 -ovalbumin coated on the surface of Fe 3 O 4 @Au nanoparticles for binding with FB 1 antibodies. Successively, horseradish peroxidase labeled goat anti-rabbit IgG (HRP-IgG) was conjugated with FB 1 antibodies on the microplate. In substrate solution containing luminol and H 2 O 2 , HRP-IgG catalyzed luminol oxidation by H 2 O 2 , generating a high chemiluminescence signal. The FB 1 immune GoldMag particles were characterized by Fourier transform infrared spectroscopy, scanning electron microscope and zeta potential analysis, etc. RESULTS: The concentrations and the reaction times of these immunoreagents were optimized to improve the performances of this method. The established method could detect as low as 0.027 ng mL -1 FB 1 from 0.05 ng mL -1 to 25 ng mL -1 , demonstrating little cross-reaction (less than 2.4%) with other structurally related compounds. The average intrassay relative SD (RSD) (n = 6) was 3.4% and the average interassay RSD (n = 6) was 5.4%. This method was successfully applied for the determination of FB 1 in corn and wheat and gave recoveries of between 98-110% and 91-105%, respectively. The results of the present study suggest that the MECLIA approach has potential application for high-throughput fumonisin screening in cereals. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  3. Ultrasensitive multi-analyte electrochemical immunoassay based on GNR-modified heated screen-printed carbon electrodes and PS@PDA-metal labels for rapid detection of MMP-9 and IL-6.

    Science.gov (United States)

    Shi, Jian-Jun; He, Ting-Ting; Jiang, Fang; Abdel-Halim, E S; Zhu, Jun-Jie

    2014-05-15

    An ultrasensitive electrochemical immunoassay was developed for rapid detection of interleukin-6 (IL-6) and matrix metallopeptidase-9 (MMP-9); the method utilized PS@PDA-metal nanocomposites based on graphene nanoribbon (GNR)-modified heated screen-printed carbon electrode (HSPCE). Because of the good hydrophilicity and low toxicity, GNRs were used to immobilize antibodies (Ab) and amplify the electrochemical signal. PS@PDA-metal was used to label antibodies and generate a strong electrochemical signal in acetic buffer. A sandwich strategy was adopted to achieve simultaneous detection of MMP-9 and IL-6 based on HSPCE without cross-talk between adjacent electrodes in the range of 10(-5) to 10(3) ng mL(-1) with detection limits of 5 fg mL(-1) and 0.1 pg mL(-1) (S/N=3), respectively. The proposed method showed wide detection range, low detection limit, acceptable stability and good reproducibility. Satisfactory results were also obtained in the practical samples, thus showing this is a promising technique for simultaneous clinical detection of biocomponent proteins. © 2013 Elsevier B.V. All rights reserved.

  4. Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges

    International Nuclear Information System (INIS)

    Kolosova, Anna Yu.; Sibanda, Liberty; Dumoulin, Frederic; Lewis, Janet; Duveiller, Etienne; Van Peteghem, Carlos; Saeger, Sarah de

    2008-01-01

    A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 μg kg -1 were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities

  5. Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays

    Directory of Open Access Journals (Sweden)

    John Miller

    2015-04-01

    Full Text Available We report use of U-shaped biconically tapered optical fibers (BTOF as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G-antigen (rabbit anti-mouse IgG reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  6. Determining total thyroxine with the aid of the homogeneous enzyme immunoassay

    International Nuclear Information System (INIS)

    Vogt, W.

    1978-01-01

    Total thyrozine values obtained with the aid of the homogeneous enzyme immunoassay are compared with those delivered by the RIA and the efficiency of the EMIT technique is evaluated. Some results obtained via Enzymun-T4, a heterologous enzyme immunoassay, are also given. (VJ) 891 VJ [de

  7. Development of a simple extraction procedure for chlorpyrifos determination in food samples by immunoassay.

    Science.gov (United States)

    Gabaldón, J A; Maquieira, A; Puchades, R

    2007-02-28

    The suitability of immunoassay methodology for rapid and accurate determination of chlorpyrifos in vegetables was tested. The optimised ELISA detection limit was 0.32ng/ml, with a working range from 0.69 to 6.21ng/ml and an immunoassay test-mid point (IC(50)) of 2.08ng/ml. A rapid sample preparation procedure considering different parameters such as the amount of sample, volume of extractant, extraction time and dilution factor was optimised. The developed direct extraction (DE) and multiresidue (ME) standard procedures were performed in different fortified fresh and processed vegetable samples (tomato, bonnet pepper, bean, pea, asparagus, broccoli, watermelon, melon, lettuce, cucumber, celery and red pepper). Recoveries were in all cases in the whole range 85.2-108.9% for both DE and ME extracts. Also, the comparison of the results obtained by both immunochemical and chromatographic methods for spiked fruits and vegetables were good with a correlation coefficient (r) of 0.97.

  8. Nanogold–polyaniline–nanogold microspheres-functionalized molecular tags for sensitive electrochemical immunoassay of thyroid-stimulating hormone

    International Nuclear Information System (INIS)

    Cui Yuling; Chen Huafeng; Hou Li; Zhang Bing; Liu Bingqian; Chen Guonan; Tang Dianping

    2012-01-01

    Highlights: ► A novel immunosensing strategy was designed for detection of thyroid-stimulating hormone. ► Using nanogold–polyaniline–nanogold microspheres as molecular tags. ► Improvement of electrochemical activity of nanolabels. ► Combination enzyme labels with nanolabels for signal amplification. - Abstract: Methods based on nanomaterial labels have been developed for electrochemical immunosensors and immunoassays, but most involved low sensitivity. Herein a novel class of molecular tags, nanogold–polyaniline–nanogold microspheres (GPGs), was first synthesized and functionalized with horseradish peroxidase-conjugated thyroid-stimulating hormone antibody (HRP-Ab 2 ) for sensitive electrochemical immunoassay of thyroid-stimulating hormone (TSH). X-ray diffraction, confocal Raman spectroscopy, scanning electron microscope and transmission electron microscope were employed to characterize the prepared GPGs. Based on a sandwich-type immunoassay format, the assay was performed in pH 5.0 acetate buffer containing 6.0 mmol L −1 H 2 O 2 by using GPG-labeled HRP-Ab 2 as molecular tags. Compared with pure polyaniline nanospheres and gold nanoparticles alone, the GPG hybrid nanostructures increased the surface area of the nanomaterials, and enhanced the immobilized amount of HRP-Ab 2 . Several labeling protocols comprising HRP-Ab 2 , nanogold particle-labeled HRP-Ab 2 , and polyaniline nanospheres-labeled HRP-Ab 2 , were also investigated for determination of TSH and improved analytical features were obtained by using the GPG-labeled HRP-Ab 2 . With the GPG labeling method, the effects of incubation time and pH of acetate buffer on the current responses of the immunosensors were also studied. The strong attachment of HRP-Ab 2 to the GPGs resulted in a good repeatability and intermediate precision down to 7%. The dynamic concentration range spanned from 0.01 to 20 μIU mL −1 with a detection limit (LOD) of 0.005 μIU mL −1 TSH at the 3s B criterion

  9. Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) in toxicological analysis. Studies on the detection of clobenzorex and its metabolites within a systematic toxicological analysis procedure by GC-MS and by immunoassay and studies on the detection of alpha- and beta-amanitin in urine by atmospheric pressure ionization electrospray LC-MS.

    Science.gov (United States)

    Maurer, H H; Kraemer, T; Ledvinka, O; Schmitt, C J; Weber, A A

    1997-02-07

    GC-MS is the method of choice for toxicological analysis of toxicants volatile in GC while non-volatile and/or thermally labile toxicants need LC-MS for their determination. Studies are presented on the toxicological detection of the amphetamine-like anorectic clobenzorex in urine by GC-MS after acid hydrolysis, extraction and acetylation and by fluorescence polarization immunoassay (FPIA, TDx (meth)amphetamine II). After ingestion of 60 mg of clobenzorex, the parent compound and/or its metabolites could be detected by GC-MS for up to 84 h or by FPIA for up to 60 h. Since clobenzorex shows no cross-reactivity with the used immunoassay, the N-dealkylated metabolite amphetamine is responsible for the positive TDx results. The intake of clobenzorex instead of amphetamine can be differentiated by GC-MS detection of hydroxyclobenzorex which is detectable for at least as long as amphetamine. In addition, the described GC-MS procedure allows the simultaneous detection of most of the toxicologically relevant drugs. Furthermore, studies are described on the atmospheric pressure ionization electrospray LC-MS detection of alpha- and beta-amanitin, toxic peptides of amanita mushrooms, in urine after solid-phase extraction on RP-18 columns. Using the single ion monitoring mode with the ions m/z 919 and 920 the amanitins could be detected down to 10 ng/ml of urine which allows us to diagnose intoxications with amanita mushrooms.

  10. Comparison of Immunoassay methods for T3, T4 and TSH

    International Nuclear Information System (INIS)

    Alonso Rodríguez, Celia A.

    2016-01-01

    Measurements of T3, T4 and TSH have been considered very important in the diagnosis and monitoring of thyroid diseases both overt and subclinical. These subclinical diseases are actively seeking for years, both in healthy patients and hospitalized for other illnesses; and in the population over 35 years, especially women, in health checkups. The active search for these diseases requires the use of rapid and reliable techniques; that can be developed massively, with good level of detectability and comparable. The overall objective is to present the evaluation of different immunoassay techniques with respect to the RIA and IRMA: ELISA, chemiluminescence, Amplified Chemiluminescence, electrochemiluminescence Immunofluorescence. Compare including automatic methods and analyze the cost and feasibility of them for laboratory immunoassay. ELISA colorimetric technique for dosing was comparable to RIA T4, not for T3. Chemiluminescence (AMERLITE) compared to dosing RIA and IRMA T4 to TSH proved to be valid for both. Amplified Chemiluminescence (Immulite) compared to IRMA for TSH was no significant difference. Electrochemiluminescence (Elecsys 2010) compared to T3 and T4 RIA and IRMA for TSH, no significant differences for T4 and TSH; but no variation to T3. Immunofluorescence (AIA-600) used to compare with RIA for T3 and T4, and TSH IRMA, no significant differences for the measured analytes. Benchmarking of automatic methods suggests that the most thrifty of trials is Immunofluorescence the AIA-600, regarding calibration and control, programming time, randomization and the ability to save the value of the fluorescence deferred calculations for tests without valid at the time of realizing calibration. Analyzing the cost and feasibility of these methods for laboratory immunoassay, we must consider that their characteristics electrochemiluminescence is the fastest, but its price is prohibitive for our health systems. The AIA-600 appears to be the method of choice for its

  11. Multiplex Immunoassay Profiling of Hormones Involved in Metabolic Regulation.

    Science.gov (United States)

    Stephen, Laurie; Guest, Paul C

    2018-01-01

    Multiplex immunoassays are used for rapid profiling of biomarker proteins and small molecules in biological fluids. The advantages over single immunoassays include lower sample consumption, cost, and labor. This chapter details a protocol to develop a 5-plex assay for glucagon-like peptide 1, growth hormone, insulin, leptin, and thyroid-stimulating hormone on the Luminex ® platform. The results of the analysis of insulin in normal control subjects are given due to the important role of this hormone in nutritional programming diseases.

  12. Designing novel nano-immunoassays: antibody orientation versus sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Puertas, S; Moros, M; Fernandez-Pacheco, R; Ibarra, M R; Grazu, V; De la Fuente, J M, E-mail: vgrazu@unizar.e, E-mail: jmfuente@unizar.e [Instituto de Nanociencia de Aragon (INA), Universidad de Zaragoza, Campus RIo Ebro, EdifIcio I-D, Mariano Esquillor, s/n, 50018 Zaragoza (Spain)

    2010-12-01

    There is a growing interest in the use of magnetic nanoparticles (MNPs) for their application in quantitative and highly sensitive biosensors. Their use as labels of biological recognition events and their detection by means of some magnetic method constitute a very promising strategy for quantitative high-sensitive lateral-flow assays. In this paper, we report the importance of nanoparticle functionalization for the improvement of sensitivity for a lateral-flow immunoassay. More precisely, we have found that immobilization of IgG anti-hCG through its polysaccharide moieties on MNPs allows more successful recognition of the hCG hormone. Although we have used the detection of hCG as a model in this work, the strategy of binding antibodies to MNPs through its sugar chains reported here is applicable to other antibodies. It has huge potential as it will be very useful for the development of quantitative and high-sensitive lateral-flow assays for its use on human and veterinary, medicine, food and beverage manufacturing, pharmaceutical, medical biologics and personal care product production, environmental remediation, etc.

  13. Strategies of Life Detection

    CERN Document Server

    Botta, Oliver; Gomez-Elvira, Javier; Javaux, Emmanuelle; Selsis, Franck; Summons, Roger

    2008-01-01

    The search for life outside the Earth has been one of mankind's most challenging quests. We have reached a level of technology that allows for initial steps toward thorough scientific investigation. The aim of this workshop was to take an interdisciplinary look at the signatures that would be indicative of past or present life on another planet and compare them to biosignatures on Earth. The purpose of the workshop was also to discuss state-of-the-art in-situ instruments that are envisioned to search for these signatures in the exploration of the solar system, as well as the discussion of concepts descriptive of the search for habitable planets around other stars. This book is intended to provide a reference to scientists and instrument developers working in the field of in-situ and remote life detection. It can also be used as an interdisciplinary introduction for students and post-doctoral researchers entering this new and exciting field.

  14. Potential applications of immunoassays in studies of flatfish recruitment

    Science.gov (United States)

    Feller, Robert J.

    The fisheries recruitment-stock problem, a lack of correlation between measures of reproductive output of the parent stock and recruitment to the fishery, has several potential biotic and abiotic causes. Immunoassays may be useful in examining several aspects of this and several other problems in flatfish ecology: stock identification, parasitism and disease, and trophic interactions. Given stage-specific antisera capable of recognozing antigenic moieties of, for instance, eggs, larvae, or newly-settled juveniles, it is possible to screen stomach contents of many putative predators ( e.g., shrimp or crabs) rapidly for the presence and amounts of platfish prey. This trophic application of immunological methods has great promise for measuring loss of potential recruits to predation. All immunoassays are limited by the quality of antisera used and the researcher's ability to interpret quantitative data in an ecologically meaningful way. Key references for applications of immunoassays in fish-related questions are provided with recommendations for their utilization.

  15. Possibilities for the detection of microbial life on extrasolar planets.

    Science.gov (United States)

    Knacke, Roger F

    2003-01-01

    We consider possibilities for the remote detection of microbial life on extrasolar planets. The Darwin/Terrestrial Planet Finder (TPF) telescope concepts for observations of terrestrial planets focus on indirect searches for life through the detection of atmospheric gases related to life processes. Direct detection of extraterrestrial life may also be possible through well-designed searches for microbial life forms. Satellites in Earth orbit routinely monitor colonies of terrestrial algae in oceans and lakes by analysis of reflected ocean light in the visible region of the spectrum. These remote sensing techniques suggest strategies for extrasolar searches for signatures of chlorophylls and related photosynthetic compounds associated with life. However, identification of such life-related compounds on extrasolar planets would require observations through strong, interfering absorptions and scattering radiances from the remote atmospheres and landmasses. Techniques for removal of interfering radiances have been extensively developed for remote sensing from Earth orbit. Comparable techniques would have to be developed for extrasolar planet observations also, but doing so would be challenging for a remote planet. Darwin/TPF coronagraph concepts operating in the visible seem to be best suited for searches for extrasolar microbial life forms with instruments that can be projected for the 2010-2020 decades, although resolution and signal-to-noise ratio constraints severely limit detection possibilities on terrestrial-type planets. The generation of telescopes with large apertures and extremely high spatial resolutions that will follow Darwin/TPF could offer striking possibilities for the direct detection of extrasolar microbial life.

  16. An accurate, specific, sensitive, high-throughput method based on a microsphere immunoassay for multiplex detection of three viruses and bacterial fruit blotch bacterium in cucurbits.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Makornwattana, Manlika; Himananto, Orawan; Seepiban, Channarong; Phuengwas, Sudtida; Warin, Nuchnard; Gajanandana, Oraprapai; Karoonuthaisiri, Nitsara

    2017-09-01

    To employ a microsphere immunoassay (MIA) to simultaneously detect multiple plant pathogens (potyviruses, Watermelon silver mottle virus, Melon yellow spot virus, and Acidovorax avenae subsp. citrulli) in actual plant samples, several factors need to be optimized and rigorously validated. Here, a simple extraction method using a single extraction buffer was successfully selected to detect the four pathogens in various cucurbit samples (cucumber, cantaloupe, melon, and watermelon). The extraction method and assay performance were validated with inoculated and field cucurbit samples. The MIA showed 98-99% relative accuracy, 97-100% relative specificity and 92-100% relative sensitivity when compared to commercial ELISA kits and reverse transcription PCR. In addition, the MIA was also able to accurately detect multiple-infected field samples. The results demonstrate that one common extraction method for all tested cucurbit samples could be applied to detect multiple pathogens; avoiding the need for multiple protocols to be employed. This multiplex method can therefore be instrumental for high-throughput screening of multiple plant pathogens with many advantages such as a shorter assay time (2.5h) with single assay format, a lower cost of detection ($5 vs $19.7 for 4 pathogens/sample) and less labor requirement. Its multiplex capacity can also be expanded to detect up to 50 different pathogens upon the availability of specific antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    Science.gov (United States)

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime

  18. Development of a novel ultrasensitive enzyme immunoassay for human glutamic acid decarboxylase 65 antibody.

    Science.gov (United States)

    Numata, Satoshi; Katakami, Hideki; Inoue, Shinobu; Sawada, Hirotake; Hashida, Seiichi

    2016-07-01

    We developed a novel, ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for determination of glutamic acid decarboxylase autoantibody concentrations in serum samples from patients with type 2 diabetes. We developed an immune complex transfer enzyme immunoassay for glutamic acid decarboxylase autoantibody and measured glutamic acid decarboxylase autoantibody from 22 patients with type 1 diabetes, 29 patients with type 2 diabetes, and 32 healthy controls. A conventional ELISA kit identified 10 patients with type 1 diabetes and one patient with type 2 diabetes as glutamic acid decarboxylase autoantibody positive, whereas 15 patients with type 1 diabetes and six patients with type 2 diabetes were identified as glutamic acid decarboxylase autoantibody positive using immune complex transfer enzyme immunoassay. Immune complex transfer enzyme immunoassay is a highly sensitive and specific assay for glutamic acid decarboxylase autoantibody and might be clinically useful for diabetic onset prediction and early diagnosis. © The Author(s) 2016.

  19. Heparin interferes with the radioenzymatic and homogeneous enzyme immunoassays for aminoglycosides

    International Nuclear Information System (INIS)

    Krogstad, D.J.; Granich, G.G.; Murray, P.R.; Pfaller, M.A.; Valdes, R.

    1981-01-01

    Heparin interferes with measurement of aminoglycosides in serum by biological, radioenzymatic, and homogeneous enzyme immunoassay techniques, but not with radioimmunoassay. At concentrations greater than or equal to 10 5 and greater than or equal to 3 X 10 6 USP units/L, respectively, it interferes with the radioenzymatic assay by inhibiting the gentamicin 3-acetyltransferase and kanamycin 6'-acetyltransferase enzymes used in the assay. It interferes with the homogeneous enzyme immunoassays for gentamicin and tobramycin (at concentrations greater than or equal to 10 5 and greater than or equal to10 4 USP units/L, respectively), but not with the commercially available homogeneous enzyme immunoassays for other drugs. Heparin interference with the homogeneous enzyme immunoassay for aminoglycosides requires both the heparin polyanion and glucose-6-phosphate dehydrogenase bound to a cationic aminoglycoside. This interference can be reproduced with dextran sulfate (but not dextran), and does not occur with free enzyme (glucose-6-phosphate dehydrogenase) alone. Heparin interference with these two assays and at concentrations that may be present in intravenous infusions or in seriously underfilled blood-collection tubes is described

  20. Raman Life Detection Instrument Development for Icy Worlds

    Science.gov (United States)

    Thomson, Seamus; Allen, A'Lester; Gutierrez, Daniel; Quinn, Richard C.; Chen, Bin; Koehne, Jessica E.

    2017-01-01

    The objective of this project is to develop a compact, high sensitivity Raman sensor for detection of life signatures in a flow cell configuration to enable bio-exploration and life detection during future mission to our Solar Systems Icy Worlds. The specific project objectives are the following: 1) Develop a Raman spectroscopy liquid analysis sensor for biosignatures; 2) Demonstrate applicability towards a future Enceladus or other Icy Worlds missions; 3) Establish key parameters for integration with the ARC Sample Processor for Life on Icy Worlds (SPLIce); 4) Position ARC for a successful response to upcoming Enceladus or other Icy World mission instrument opportunities.

  1. Development of a monoclonal antibody-based flow-through immunoassay (FTA) for detection of white spot syndrome virus (WSSV) in black tiger shrimp Penaeus monodon.

    Science.gov (United States)

    Patil, R; Shankar, K M; Kumar, B T N; Kulkarni, A; Patil, P; Moger, N

    2013-09-01

    A flow-through immunoassay (FTA), an improved version of immunodot, was developed using a nitrocellulose membrane baked onto adsorbent pads enclosed in a plastic cassette to detect white spot syndrome virus (WSSV) in shrimp. Sharp purple dots developed with WSSV against the white background of the nitrocellulose membrane. The detection limits of WSSV by the FTA and immunodot were 0.312 and 1.2 μg mL(-1) crude WSSV protein, respectively. The FTA could be completed in 8-10 min compared with 90 min for immunodot. The FTA was 100 times more sensitive than 1-step polymerase chain reaction (PCR) and in between that of the 1- and 2-step PCR protocol recommended by the Office of International Epizootics (OIE). In experimental, orally infected shrimp post-larvae, WSSV was first detected 14, 16 and 18 h post-infection (hpi) by FTA, immunodot and one-step PCR, respectively. The FTA detected WSSV 2 and 4 h earlier than immunodot and one-step PCR, respectively. The FTA was more sensitive (25/27) than one-step PCR (23/27) and immunodot (23/27) for the detection of WSSV from white spot disease outbreak ponds. The reagent components of the FTA were stable giving expected results for 6 m at 4-8 °C. The FTA is available as a rapid test kit called 'RapiDot' for the early detection of WSSV under field conditions. © 2013 John Wiley & Sons Ltd.

  2. Improving the sensitivity of immunoassay based on MBA-embedded Au@SiO2 nanoparticles and surface enhanced Raman spectroscopy

    Science.gov (United States)

    Wei, Chao; Xu, Min-Min; Fang, Cong-Wei; Jin, Qi; Yuan, Ya-Xian; Yao, Jian-Lin

    2017-03-01

    Traditional "sandwich" structure immunoassay is mainly based on the self-assembly of "antibody on solid substrate-antigen-antibody with nanotags" architectures, and the sensitivity of this strategy is critically depended on the surface enhanced Raman scattering (SERS) activities and stability of nanotags. Therefore, the rational design and fabrication on the SERS nanotags attracts the common interests to the bio-related detecting and imaging. Herein, silica encapsulated Au with mercaptobenzoic acid (MBA) core-shell nanoparticles (Au-MBA@SiO2) are fabricated instead of the traditional naked Au or Ag nanoparticles for the SERS-based immunoassay on human and mouse IgG antigens. The MBA molecules facilitate the formation of continuous pinhole-free silica shell and are also used as SERS labels. The silica shell is employed to protect MBA labels and to isolate Au core from the ambient solution for blocking the aggregation. This shell also played the similar role to BSA in inhibiting the nonspecific bindings, which allowed the procedures for constructing "sandwich" structures to be simplified. All of these merits of the Au-MBA@SiO2 brought the high performance in the related immunoassay. Benefiting from the introduction of silica shell to encapsulate MBA labels, the detection sensitivity was improved by about 1- 2 orders of magnitude by comparing with the traditional approach based on naked Au-MBA nanoparticles. This kind of label-embedded core-shell nanoparticles could be developed as the versatile nanotags for the bioanalysis and bioimaging.

  3. Development of an immunoassay for determination of 2,4-dichlorophenoxyacetic acid (2,4-D) based upon the recombinant Fab fragment of 2,4-D specific antibody

    Science.gov (United States)

    Nguyen, Van C.; Nguyen, Thi D. T.; Dau, Hung A.; Tham, Thu N.; Quyen, Dinh T.; Bachmman, Till; Schmid, Rolf D.

    2001-09-01

    To develop an immunoassay and further an immunosensor for 2,4-D based upon recombinant antibody, the Fab fragments of 2,4-D specific antibody were expressed in E. coli. Western blotting analysis of the periplasmic cell fractions shown that under the non-reducing condition only a single protein band at a molecular mass of 45-kDa, corresponding to the whole Fab fragment was detected. Antigen binding activity for 2,4-D was found only in the extract of cells bearing the 2,4-D plasmid. An immunoassay based on the competitive reaction of 2,4-D and enzyme tracer with 2,4-D Fab fragments immobilized on micro titer plates via rabbit anti-mouse IgC was developed. Using this assay, 2,4-D could be detected at concentration range of 0.5 (mu) g/1 to 10(mu) g/1. The center point of the 2,4-D test was found at a concentration of 5 (mu) g/l. The assay was applied for detection of 2,4-D in spiked orange samples, resulting in recovery rate of 90 percent. The immunoassay could be applied to monitor human exposure to 2,4-D from contamination in fruit samples.

  4. Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk

    Science.gov (United States)

    Shi, Qiaoqiao; Huang, Jie; Sun, Yaning; Yin, Mengqi; Hu, Mei; Hu, Xiaofei; Zhang, Zhijun; Zhang, Gaiping

    2018-05-01

    An ultrasensitive method for the detection of antibiotics in milk is developed based on inexpensive, simple, rapid and portable lateral flow immunoassay (LFI) strip, in combination with high sensitivity surface-enhanced Raman spectroscopy (SERS). In our strategy, an immunoprobe was prepared from colloidal gold (AuNPs) conjugated with both a monoclonal antibody against neomycin (NEO-mAb) and a Raman probe molecule 4-aminothiophenol (PATP). The competitive interaction with immunoprobe between free NEO and the coated antigen (NEO-OVA) resulted in the change of the amount of the immobilized immunoprobe on the paper substrate. The LFI procedure was completed within 15 min. The Raman intensity of PATP on the test line of the LFI strip was measured for the quantitative determination of NEO. The IC50 and the limit of detection (LOD) of this assay are 0.04 ng/mL and 0.216 pg/mL of NEO, respectively. There is no cross-reactivity (CR) of the assay with other compounds, showing high specificity of the assay. The recoveries for milk samples with added NEO are in the range of 89.7%-105.6% with the relative standard deviations (RSD) of 2.4%-5.3% (n = 3). The result reveals that this method possesses high specificity, sensitivity, reproducibility and stability, and can be used to detect a variety of antibiotic residues in milk samples.

  5. A redox-mediated chromogenic reaction and application in immunoassay.

    Science.gov (United States)

    Yu, Ru-Jia; Ma, Wei; Peng, Mao-Pan; Bai, Zhi-Shan; Long, Yi-Tao

    2016-08-31

    A novel redox-mediated chromogenic reaction was demonstrated based on the reaction between HAuCl4 and 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), which generate various color responses from red to green in the resulting solutions. Various redox substance could be used to mediate the reaction and trigger a distinct color response. We established a sensitive hydrogen peroxide colorimetric sensor based on the redox-mediated chromogenic reaction and depicted the application both in detection of enzyme and in an immunoassay. Combining the traditional chromogenic reagent with gold nanoparticles, our assay has the advantage in short response time (within three minutes), high sensitivity (10(-12) g mL(-1) for HBsAg) and stability. Copyright © 2016. Published by Elsevier B.V.

  6. Detection of Life Forms, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Gaia Genomics proposes to develop an instrument for the detection of earthborn and/or planetary life forms that are based on a nucleic acid paradigm. Highly...

  7. Surface modification of alignment layer by ultraviolet irradiation to dramatically improve the detection limit of liquid-crystal-based immunoassay for the cancer biomarker CA125.

    Science.gov (United States)

    Su, Hui-Wen; Lee, Mon-Juan; Lee, Wei

    2015-05-01

    Liquid crystal (LC)-based biosensing has attracted much attention in recent years. We focus on improving the detection limit of LC-based immunoassay techniques by surface modification of the surfactant alignment layer consisting of dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP). The cancer biomarker CA125 was detected with an array of anti-CA125 antibodies immobilized on the ultraviolet (UV)-modified DMOAP monolayer. Compared with a pristine counterpart, UV irradiation enhanced the binding affinity of the CA125 antibody and reproducibility of immunodetection in which a detection limit of 0.01 ng∕ml for the cancer biomarker CA125 was achieved. Additionally, the optical texture observed under a crossed polarized microscope was correlated with the analyte concentration. In a proof-of-concept experiment using CA125-spiked human serum as the analyte, specific binding between the CA125 antigen and the anti-CA125 antibody resulted in a distinct and concentration-dependent optical response despite the high background caused by nonspecific binding of other biomolecules in the human serum. Results from this study indicate that UVmodification of the alignment layer, as well as detection with LCs of large birefringence, contributes to the enhanced performance of the label-free LC-based immunodetection, which may be considered a promising alternative to conventional label-based methods.

  8. Design of a surface plasmon resonance immunoassay for therapeutic drug monitoring of amikacin.

    Science.gov (United States)

    Losoya-Leal, Adrian; Estevez, M-Carmen; Martínez-Chapa, Sergio O; Lechuga, Laura M

    2015-08-15

    The therapeutic drug monitoring (TDM) of pharmaceutical drugs with narrow therapeutic ranges is of great importance in the clinical setting. It provides useful information towards the enhancement of drug therapies, aiding in dosage control and toxicity risk management. Amikacin is an aminoglycoside antibiotic commonly used in neonatal therapies that is indicated for TDM due to the toxicity risks inherent in its use. Current techniques for TDM such as high performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GC-MS) are costly, time consuming, and cannot be performed at the site of action. Over the last decades, surface plasmon resonance (SPR) biosensors have become increasingly popular in clinical diagnostics due to their ability to detect biomolecular interactions in real-time. We present an SPR-based competitive immunoassay for the detection of the antibiotic amikacin, suitable for TDM in both adults and neonates. We have obtained high specificity and sensitivity levels with an IC50 value of 1.4ng/mL and a limit of detection of 0.13ng/mL, which comfortably comply with the drug's therapeutic range. Simple dilution of serum can therefore be sufficient to analyze low-volume real samples from neonates, increasing the potential of the methodology for TDM. Compared to current TDM conventional methods, this SPR-based immunoassay can provide advantages such as simplicity, potential portability, and label-free measurements with the possibility of high throughput. This work is the foundation towards the development of an integrated, simple use, highly sensitive, fast, and point-of-care sensing platform for the opportune TDM of antibiotics and other drugs in a clinical setting. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Antiphospholipid antibodies detected by line immunoassay differentiate among patients with antiphospholipid syndrome, with infections and asymptomatic carriers.

    Science.gov (United States)

    Roggenbuck, Dirk; Borghi, Maria Orietta; Somma, Valentina; Büttner, Thomas; Schierack, Peter; Hanack, Katja; Grossi, Claudia; Bodio, Caterina; Macor, Paolo; von Landenberg, Philipp; Boccellato, Francesco; Mahler, Michael; Meroni, Pier Luigi

    2016-05-21

    Antiphospholipid antibodies (aPL) can be detected in asymptomatic carriers and infectious patients. The aim was to investigate whether a novel line immunoassay (LIA) differentiates between antiphospholipid syndrome (APS) and asymptomatic aPL+ carriers or patients with infectious diseases (infectious diseases controls (IDC)). Sixty-one patients with APS (56 primary, 22/56 with obstetric events only, and 5 secondary), 146 controls including 24 aPL+ asymptomatic carriers and 73 IDC were tested on a novel hydrophobic solid phase coated with cardiolipin (CL), phosphatic acid, phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, phosphatidylinositol, phosphatidylserine, beta2-glycoprotein I (β2GPI), prothrombin, and annexin V. Samples were also tested by anti-CL and anti-β2GPI ELISAs and for lupus anticoagulant activity. Human monoclonal antibodies (humoAbs) against human β2GPI or PL alone were tested on the same LIA substrates in the absence or presence of human serum, purified human β2GPI or after CL-micelle absorption. Comparison of LIA with the aPL-classification assays revealed good agreement for IgG/IgM aß2GPI and aCL. Anti-CL and anti-ß2GPI IgG/IgM reactivity assessed by LIA was significantly higher in patients with APS versus healthy controls and IDCs, as detected by ELISA. IgG binding to CL and ß2GPI in the LIA was significantly lower in aPL+ carriers and Venereal Disease Research Laboratory test (VDRL) + samples than in patients with APS. HumoAb against domain 1 recognized β2GPI bound to the LIA-matrix and in anionic phospholipid (PL) complexes. Absorption with CL micelles abolished the reactivity of a PL-specific humoAb but did not affect the binding of anti-β2GPI humoAbs. The LIA and ELISA have good agreement in detecting aPL in APS, but the LIA differentiates patients with APS from infectious patients and asymptomatic carriers, likely through the exposure of domain 1.

  10. Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip)

    Science.gov (United States)

    Dong, Meili; Wu, Jiandong; Ma, Zimin; Peretz-Soroka, Hagit; Zhang, Michael; Komenda, Paul; Tangri, Navdeep; Liu, Yong; Rigatto, Claudio; Lin, Francis

    2017-01-01

    Traditional diagnostic tests for chronic diseases are expensive and require a specialized laboratory, therefore limiting their use for point-of-care (PoC) testing. To address this gap, we developed a method for rapid and low-cost C-reactive protein (CRP) detection from blood by integrating a paper-based microfluidic immunoassay with a smartphone (CRP-Chip). We chose CRP for this initial development because it is a strong biomarker of prognosis in chronic heart and kidney disease. The microfluidic immunoassay is realized by lateral flow and gold nanoparticle-based colorimetric detection of the target protein. The test image signal is acquired and analyzed using a commercial smartphone with an attached microlens and a 3D-printed chip–phone interface. The CRP-Chip was validated for detecting CRP in blood samples from chronic kidney disease patients and healthy subjects. The linear detection range of the CRP-Chip is up to 2 μg/mL and the detection limit is 54 ng/mL. The CRP-Chip test result yields high reproducibility and is consistent with the standard ELISA kit. A single CRP-Chip can perform the test in triplicate on a single chip within 15 min for less than 50 US cents of material cost. This CRP-Chip with attractive features of low-cost, fast test speed, and integrated easy operation with smartphones has the potential to enable future clinical PoC chronic disease diagnosis and risk stratification by parallel measurements of a panel of protein biomarkers. PMID:28346363

  11. A harmonized immunoassay with liquid chromatography-mass spectrometry analysis in egg allergen determination.

    Science.gov (United States)

    Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro

    2018-01-01

    Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.

  12. Interference in immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Interfering factors are evident in both limited reagent (radioimmunoassay) and excess reagent (immunometric assay) technologies and should be suspected whenever there is a discrepancy between analytical results and clinical findings in the investigation of particular diseases. The overall effect of interference in immunoassay is analytical bias in result, either positive or negative of variable magnitude. The interference maybe caused by a wide spectrum of factors from poor sample collection and handling to physiological factors e.g. lipaemia, heparin treatment, binding protein abnormalities, autoimmunity and drug treatments. The range of interfering factors is extensive and difficult to discuss effectively in a short review

  13. Synthesis-based approach toward direct sandwich immunoassay for ciguatoxin CTX3C.

    Science.gov (United States)

    Oguri, Hiroki; Hirama, Masahiro; Tsumuraya, Takeshi; Fujii, Ikuo; Maruyama, Megumi; Uehara, Hisatoshi; Nagumo, Yoko

    2003-06-25

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of ciguatoxin CTX3C were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens, 3 and 4, in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C itself. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C at the ppb level with no cross-reactivity against other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin.

  14. Procedures for Sensitive Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Givol, D. [Department of Chemical Immunology, Weizmann Institute of Science, Rehovot (Israel)

    1970-02-15

    Sensitive immunoassay methods should be applied to small molecules of biological importance, which are non-immunogenic by themselves, such as small peptide hormones (e.g. bradykinin), plant hormones (e.g. indoleacetic acid), nucleotides and other small molecules. Methods of binding these small molecules, as haptens, to immunogenic carriers by various cross-linking agents are described (dicyclohexylcarbodiimide, tolylene-diisocyanate and glutaraldehyde), and the considerations involved in relation to the methods of binding and the specificity of the antibodies formed are discussed. Some uses of antibody bound to bromoacetyl cellulose as an immuno adsorbent convenient for assay of immunoglobulins are described. Finally, the sensitive immunoassay method of chemically modified phage is described. This includes methods of binding small molecules (such as the dinitrophenyl group, penicillin, indoleacetic acid) or proteins (such as insulin, immunoglobulins) to phages. Methods of direct chemical conjugation, or an indirect binding via anti-phage Fab, are described. The phage inactivation method by direct plating and its modifications (such as decision technique and complex inactivation) are compared with the more simple end-point titration method. The inhibition of phage inactivation has some advantages as it does not require radioactive material, or expensive radioactive counters, and avoids the need for separation between bound and unbound antigen. Hence, if developed, it could be used as an alternative to radioimmunoassay. (author)

  15. Quantitation of estrogen receptor in seventy-five specimens of breast cancer: comparison between an immunoassay (Abbott ER-EIA monoclonal) and a [3H]estradiol binding assay based on isoelectric focusing in polyacrylamide gel

    International Nuclear Information System (INIS)

    Pousette, A.; Gustafsson, S.A.; Thoernblad, A.M.N.; Nordgren, A.; Saellstroem, J.Li.; Lindgren, A.; Sundelin, P.; Gustafsson, J.A.

    1986-01-01

    Quantitation of estrogen receptor has been performed in cytosol prepared from 75 specimens of breast cancer tissue from patients who had not received hormonal therapy. The study was performed in order to compare an immunoassay (Abbott Laboratories, North Chicago, IL) with our currently used method for estrogen receptor analysis based on isoelectric focusing of [ 3 H]estradiol-receptor complex in polyacrylamide gels. Using linear regression analysis, a regression coefficient (slope) of 1.30 and a correlation coefficient of 0.75 were calculated. The differences in results between the two methods are probably partly explained by the fact that the ligand-based method only measures unoccupied receptor, whereas the immunoassay detects the total amount of receptor, resulting in generally slightly higher concentrations with the latter method. However, in five of 75 specimens the ligand-based method gave a considerably higher concentration of estrogen receptor. This was most probably explained by partial proteolysis resulting in the formation of receptor fragment(s), which was undetectable with the immunoassay but detectable with the ligand-based method. These observations underline the importance of careful handling of specimens during the whole immunoassay procedure

  16. Myeloma-Derived Light Chain Paired with a Diagnostic Monoclonal Antibody Hinders Immunoassay Performance.

    Science.gov (United States)

    Tu, Bailin; Tieman, Bryan; Moore, Jeffrey; Pan, You; Muerhoff, A Scott

    2017-06-01

    Monoclonal antibodies are widely used as the capture and detection reagents in diagnostic immunoassays. In the past, myeloma fusion partners expressing endogenous heavy and/or light chains were often used to generate hybridoma cell lines. As a result, mixed populations of antibodies were produced that can cause inaccurate test results, poor antibody stability, and significant lot-to-lot variability. We describe one such scenario where the P3U1 (P3X63Ag8U.1) myeloma fusion partner was used in the generation of a hybridoma producing protein induced vitamin K absence/antagonist-II (PIVKA II) antibody. The hybridoma produces three subpopulations of immunoglobulin as determined by ion exchange (IEx) chromatography that exhibit varying degrees of immunoreactivity (0%, 50%, or 100%) to the target antigen as determined by Surface Plasmon Resonance. To produce an antibody with the highest possible sensitivity and specificity, the antigen-specific heavy and light chain variable domains (VH and VL) were cloned from the hybridoma and tethered to murine IgG1 and kappa scaffolds. The resulting recombinant antibody was expressed in Chinese hamster ovary cells and is compatible for use in a diagnostic immunoassay.

  17. Immunoassay for determination of trilobolide

    Czech Academy of Sciences Publication Activity Database

    Huml, L.; Jurášek, M.; Mikšátková, P.; Zimmermann, T.; Tomanová, P.; Buděšínský, Miloš; Rottnerová, Z.; Šimková, M.; Harmatha, Juraj; Kmoníčková, Eva; Lapčík, O.; Drašar, P. B.

    2017-01-01

    Roč. 117, Jan (2017), s. 105-111 ISSN 0039-128X. [Conference on Isoprenoids /23./. Minsk, 04.09.2016-07.09.2016] Institutional support: RVO:61388963 ; RVO:68378041 Keywords : trilobolide * avidin-biotin * ELISA * Laser trilobum * synthesis * immunoassay Subject RIV: CE - Biochemistry; FR - Pharmacology ; Medidal Chemistry (UEM-P) OBOR OECD: Biochemical research methods; Pharmacology and pharmacy (UEM-P) Impact factor: 2.282, year: 2016

  18. Rapid screening of aflatoxin B1 in beer by fluorescence polarization immunoassay.

    Science.gov (United States)

    Beloglazova, N V; Eremin, S A

    2015-09-01

    This manuscript describes the development of a sensitive, fast and easily-performed fluorescence polarization immunoassay (FPIA) for the mycotoxin aflatoxin B1 (AFB1) in various beer samples, both lager and dark. The highest sensitivity was determined for six poly- and monoclonal antibodies selective towards aflatoxins. The sample pretreatment design was emphasized since beer samples are characterized by extremely diverse matrices. Herein, the choice of sorbent for effective removal of matrix interferences prior to analysis was crucial. The samples were diluted with a borate buffer solution containing 1% PEG 6000 and passed through the clean-up column packed with NH2-derivated silica. This sample pretreatment technique was perfectly suitable for the FPIA of lager beer samples, but for dark beer and ale it did not suffice. An artificial matrix was constructed to plot a calibration curve and quantify the results of the latter samples. The developed immunoassay was characterized by a limit of detection of 1 ng mL(-1). Apparent recovery values of 89-114% for lager and 80-125% for dark beer were established. The FPIA data for AFB1 was characterized by elevated linear regression coefficients, 0.9953 for spiked lager and 0.9895 for dark beer samples respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Weijun; Leach, Robin; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srinivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

  20. Screening for cystic fibrosis via a magnetic and microfluidic immunoassay format with electrochemical detection using a copper nanoparticle-modified gold electrode

    International Nuclear Information System (INIS)

    Benuzzi, Maria Luz Scala; Pereira, Sirley V.; Raba, Julio; Messina, Germán A.

    2016-01-01

    This article describes a microfluidic electrochemical immunoassay that features two strategies, viz. (a), the incorporation of magnetic nanoparticles (MNPs) into the central microfluidic channel and acting as a bioaffinity support for the immobilization of the antibody against the immunoreactive trypsin (anti-IRT), and (b), the electrodeposition of copper nanoparticles (CuNPs) on a gold electrode. IRT, a marker for cystic fibrosis, is extracted from blood samples onto a disk using ultrasonication, eluted, and then injected into the detection system where it is captured by anti-IRT-loaded nanoparticles (anti-IRT-Ab-MNPs). Bound IRT is electrochemically quantified after addition of HRP-labeled anti-IRT-Ab which, in the presence of H 2 O 2 , catalyzes the oxidation of catechol to form o-benzoquinone which is detected at a working potential of −1 50 mV (vs. Ag/AgCl). The electrochemical response to benzoquinone is proportional to the concentration of IRT in the range from 0 to 580 ng⋅mL −1 . The coefficients of variation are <5 % for within-day assays, and <6.4 % for between-day assays. The method was compared to a commercial ELISA for IRT where is showed a correlation coefficient of close to 1. In our perception, this approach represents an attractive alternative to existing methods for screening newborns for cystic fibrosis. (author)

  1. Clinical significance of quantitative analysis of thyroid peroxidase antibody (TPOAb) with chemiluminescence enzyme immunoassay

    International Nuclear Information System (INIS)

    Zhu Cuiying; Wang Qing; Huang Gang

    2004-01-01

    Objective: The only method of laboratory diagnosis for autoimmune thyroid diseases used to be serum TGA and TMA detections. Morerecently, quantitative analysis of TPOAb has been introduced. To assess the relative sensitivity of these tests , positive rates detected with the respective tests were compared. Methods: Serum TGA, TMA (with RIA) and TPOAb (with chemiluminescence enzyme immunoassay) were simultaneously detected in 998 cases of thyroid diseases (hyperthyroidism 307, Hashimoto's disease 193, simple goiter 498). For complementary sake, fine needle aspiration cytology was obtained in a number of cases including all the patients with Hashimoto's disease. Results: Positive detection rate of TPOAb in three groups of patients (hyperthyroidism, Hashimoto's, simple goiter) was 81.76%, 96.89 % and 42.97% respectively. With TMA, the positive rate was only 54.72%, 65.80%, 22.09% respectively. About one third more cases would be detected with the newer method. Conclusion: For the laboratory detection of auto immune thyroid diseases, quantitative analysis of TPOAb is much wore sensitive than the conventional TMA detection. (authors)

  2. Magnetic Particle-Based Immunoassay of Phosphorylated p53 Using Protein-Cage Templated Lead Phosphate and Carbon Nanospheres for Signal Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Aiqiong; Bao, Yuanwu; Ge, Xiaoxiao; Shin, Yongsoon; Du, Dan; Lin, Yuehe

    2012-11-20

    Phosphorylated p53 at serin 15 (phospho-p53-15) is a potential biomarker of Gamma-radiation exposure. In this paper, we described a new magnetic particles (MPs)-based electrochemical immunoassay of human phospho-p53-15 using carbon nanospheres (CNS) and protein-cage templated lead phosphate nanoparticles for signal amplification. Greatly enhanced sensitivity was achieved by three aspects: 1) The protein-cage nanoparticle (PCN) and p53-15 signal antibody (p53-15 Ab2) are linked to CNS (PCNof each apoferritin; 3) MPs capture a large amount of primary antibodies. Using apoferritin templated metallic phosphate instead of enzyme as label has the advantage of eliminating the addition of mediator or immunoreagents and thus makes the immunoassay system simpler. The subsequent stripping voltammetric analysis of the released lead ions were detected on a disposable screen printed electrode. The response current was proportional to the phospho-p53-15 concentration in the range of 0.02 to 20 ng mL-1 with detection limit of 0.01 ng mL-1. This method shows a good stability, reproducibility and recovery.

  3. FY1995 development of a novel rapid immunoassay technology; 1995 nendo shinkina kosoku men'eki sokutei gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    By utilizing the phenomenon that the antigen induces association of VH and VL, which are the antigen-recognizing fragments of antibody, develop a novel rapid immunoassay technology which will eliminate the defects of conventional immunoassays, such as long measuring time and requirement of expensive large automated apparatus. In addition, develop a methodology to make Fvs with low VH-VL affinity but that associate tightly in the presence of antigen. Using a model anti-hen egg lysozyme antibody HyHEL-10 Fv and BlAcore, we have clarified the kinetic basis of the Fv stabilization by HEL. By labeling HyHEL-10 VH, VL with succinimide esters of fluorescein and tetramethylrhodamin, respectively, at their N-termini, we could successfully detect VH-VL association by the increment of fluorescence resonance energy transfer. As a result, 1 {mu} g/ml of antigen could be detected homogeneously in less than 5 minutes. Some VH-VL association measurement systems were made by utilizing M13 phage display of VH fragments of HyHEL-10, anti-nitrophenacetyl, anti-digoxin antibodies. (NEDO)

  4. BIOTIN INTERFERENCE WITH ROUTINE CLINICAL IMMUNOASSAYS: UNDERSTAND THE CAUSES AND MITIGATE THE RISKS.

    Science.gov (United States)

    Samarasinghe, Shanika; Meah, Farah; Singh, Vinita; Basit, Arshi; Emanuele, Nicholas; Emanuele, Mary Ann; Mazhari, Alaleh; Holmes, Earle W

    2017-08-01

    The objectives of this report are to review the mechanisms of biotin interference with streptavidin/biotin-based immunoassays, identify automated immunoassay systems vulnerable to biotin interference, describe how to estimate and minimize the risk of biotin interference in vulnerable assays, and review the literature pertaining to biotin interference in endocrine function tests. The data in the manufacturer's "Instructions for Use" for each of the methods utilized by seven immunoassay system were evaluated. We also conducted a systematic search of PubMed/MEDLINE for articles containing terms associated with biotin interference. Available original reports and case series were reviewed. Abstracts from recent scientific meetings were also identified and reviewed. The recent, marked, increase in the use of over-the-counter, high-dose biotin supplements has been accompanied by a steady increase in the number of reports of analytical interference by exogenous biotin in the immunoassays used to evaluate endocrine function. Since immunoassay methods of similar design are also used for the diagnosis and management of anemia, malignancies, autoimmune and infectious diseases, cardiac damage, etc., biotin-related analytical interference is a problem that touches every area of internal medicine. It is important for healthcare personnel to become more aware of immunoassay methods that are vulnerable to biotin interference and to consider biotin supplements as potential sources of falsely increased or decreased test results, especially in cases where a lab result does not correlate with the clinical scenario. FDA = U.S. Food & Drug Administration FT3 = free tri-iodothyronine FT4 = free thyroxine IFUs = instructions for use LH = luteinizing hormone PTH = parathyroid hormone SA/B = streptavidin/biotin TFT = thyroid function test TSH = thyroid-stimulating hormone.

  5. Determination of five abused drugs in nitrite-adulterated urine by immunoassays and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsai, S C; ElSohly, M A; Dubrovsky, T; Twarowska, B; Towt, J; Salamone, S J

    1998-10-01

    The adulteration of urine specimens with nitrite ion hasseen shown to mask the gas chromatography-mass spectrometry (GC-MS) confirmation testing of marijuana use. This study was designed to further investigate the effect of nitrite adulteration on the detection of five commonly abused drugs by immunoassay screening and GC-MS analysis. The drugs tested are cocaine metabolite (benzoylecgonine), morphine, 11-nor-delta-tetrahydrocannabinol-9-carboxylic acid (THCCOOH), amphetamine, and phencyclidine. The immunoassays evaluated included the instrument-based Abuscreen ONLINE assays, the on-site Abuscreen ONTRAK assays, and the one-step ONTRAK TESTCUP-5 assay. Multianalyte standards containing various levels of drugs were used to test the influence of both potassium and sodium nitrite. In the ONLINE immunoassays, the presence of up to 1.0M nitrite in the multianalyte standards had no significant effect for benzoylecgonine, morphine, and phencyclidine assays. With a high concentration of nitrite, ONLINE became more sensitive for amphetamine (detected more drug than what was expected) and less sensitive for THCCOOH (detected less drug than what was expected). No effects of nitrite were observed on the results of the Abuscreen ONTRAK assays. Similarly, no effects were observed on the absolute qualitative results of the TESTCUP-5 when testing the nitrite-adulterated standards. However, the produced intensities of the signals that indicate the negative test results were slightly lowered in the THC and phencyclidine assays. The presence of 1.0M of nitrite did not show dramatic interference with the GC-MS analysis of benzoylecgonine, morphine, amphetamine, and phencyclidine. In contrast, nitrite ion significantly interfered with the detection of THCCOOH by GC-MS. The presence of 0.03M of nitrite ion resulted in significant loss in the recovery of THCCOOH and its internal standard by GC-MS. The problem of nitrite adulteration could be alleviated by sodium bisulfite treatment even

  6. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    International Nuclear Information System (INIS)

    Meimaridou, Anastasia; Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios; Pulkrabova, Jana; Hajslova, Jana; Nielen, Michel W.F.

    2010-01-01

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC 50 of 0.3 μg L -1 using a monoclonal antibody (Mab22F12) against BaP, similar to the IC 50 of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction procedure which are

  7. Giant unilamellar vesicles containing Rhodamine 6G as a marker for immunoassay of bovine serum albumin and lipocalin-2.

    Science.gov (United States)

    Sakamoto, Misato; Shoji, Atsushi; Sugawara, Masao

    2016-07-15

    Functionalized giant unilamellar vesicles (GUVs) containing a fluorescence dye Rhodamine 6G is proposed as a marker in sandwich-type immunoassay for bovine serum albumin (BSA) and lipocalin-2 (LCN2). The GUVs were prepared by the electroformation method and functionalized with anti-BSA antibody and anti-LCN2 antibody, respectively. The purification of antibody-modified GUVs was achieved by conventional centrifugation and a washing step in a flow system. To antigen on an antibody slip, antibody-modified GUVs were added as a marker and incubated. After wash-out of excess reagents and lysis of the bound GUVs with Triton X-100, the fluorescence image was captured. The fluorometric immunoassays for BSA and LCN2 exhibited lower detection limits of 4 and 80 fg ml(-)(1), respectively. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  9. Effect of serum heat-inactivation and dilution on detection of anti-WNV antibodies in mice by West Nile virus E-protein microsphere immunoassay.

    Directory of Open Access Journals (Sweden)

    Madhuri Namekar

    Full Text Available Immunopathogenesis studies employing West Nile virus (WNV mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.

  10. Automation on an Open-Access Platform of Alzheimer's Disease Biomarker Immunoassays.

    Science.gov (United States)

    Gille, Benjamin; Dedeene, Lieselot; Stoops, Erik; Demeyer, Leentje; Francois, Cindy; Lefever, Stefanie; De Schaepdryver, Maxim; Brix, Britta; Vandenberghe, Rik; Tournoy, Jos; Vanderstichele, Hugo; Poesen, Koen

    2018-04-01

    The lack of (inter-)laboratory standardization has hampered the application of universal cutoff values for Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers and their transfer to general clinical practice. The automation of the AD biomarker immunoassays is suggested to generate more robust results than using manual testing. Open-access platforms will facilitate the integration of automation for novel biomarkers, allowing the introduction of the protein profiling concept. A feasibility study was performed on an automated open-access platform of the commercial immunoassays for the 42-amino-acid isoform of amyloid-β (Aβ 1-42 ), Aβ 1-40 , and total tau in CSF. Automated Aβ 1-42 , Aβ 1-40 , and tau immunoassays were performed within predefined acceptance criteria for bias and imprecision. Similar accuracy was obtained for ready-to-use calibrators as for reconstituted lyophilized kit calibrators. When compared with the addition of a standard curve in each test run, the use of a master calibrator curve, determined before and applied to each batch analysis as the standard curve, yielded an acceptable overall bias of -2.6% and -0.9% for Aβ 1-42 and Aβ 1-40 , respectively, with an imprecision profile of 6.2% and 8.4%, respectively. Our findings show that transfer of commercial manual immunoassays to fully automated open-access platforms is feasible, as it performs according to universal acceptance criteria.

  11. Detection of analyte binding to microarrays using gold nanoparticle labels and a desktop scanner

    DEFF Research Database (Denmark)

    Han, Anpan; Dufva, Martin; Belleville, Erik

    2003-01-01

    on gold nanoparticle labeled antibodies visualized by a commercial, office desktop flatbed scanner. Scanning electron microscopy studies showed that the signal from the flatbed scanner was proportional to the surface density of the bound antibody-gold conjugates, and that the flatbed scanner could detect...... six attomoles of antibody-gold conjugates. This detection system was used in a competitive immunoassay to measure the concentration of the pesticide metabolite 2,6-dichlorobenzamide (BAM) in water samples. The results showed that the gold labeled antibodies functioned comparably with a fluorescent...... based immunoassay for detecting BAM in water. A qualitative immunoassay based on gold-labeled antibodies could determineif a water sample contained BAM above and below 60-70 ng L(-1), which is below the maximum allowed BAM concentration for drinking water (100 ng L(-1)) according to European Union...

  12. Detection of Total Ergot Alkaloids in Cereal Flour and in Bread by a Generic Enzyme Immunoassay Method.

    Science.gov (United States)

    Gross, Madeleine; Curtui, Valeriu; Usleber, Ewald

    2018-05-01

    Four sets of polyclonal antibodies against ergot alkaloids ergometrine, ergotamine, α-ergocryptine, and ergocornine were produced and characterized in a competitive direct or indirect enzyme immunoassay (EIA). Standard curve LODs were 0.03 ng/mL (ergometrine EIA) to 2.0 ng/mL (ergocornine EIA). Three EIAs were highly specific, whereas the ergometrine EIA had a broad specificity pattern and reacted, albeit weakly, with all seven major ergot alkaloids and their epimeric forms. Using the ergometrine EIA, a generic test system was established in which total ergot alkaloids are quantified by a standard curve for a toxin mixture composed of three alkaloids that matched the ergot alkaloid composition in naturally contaminated rye and wheat products. Sample extraction with acetonitrile-phosphate-buffered saline at pH 6.0 without further cleanup was sufficient for EIA analysis. The LODs for total ergot alkaloids were 20 ng/g in rye and wheat flour and 14 ng/g in bread. Recoveries were 85-110% (RSDs of 0.1-11.7%) at a concentration range of 50-1000 ng/g. The total ergot alkaloid EIA was validated by comparison with HPLC-fluorescence detection. Although some under- and overestimation by the total ergot alkaloid EIA was observed, it was suitable for the reliable identification of positive samples at 10-20 ng/g and for the determination of total ergot alkaloids in a concentration range between 100 and 1000 ng/g.

  13. Enzyme immunoassay for rabies antibody in hybridoma culture fluids and its application to differentiation of street and laboratory strains of rabies virus.

    OpenAIRE

    Smith, J S; Sumner, J W; Roumillat, L F

    1984-01-01

    A rapid and sensitive enzyme immunoassay is described for detecting rabies antibody in hybridoma culture fluids. Glass fiber filter disks were used to immobilize gamma-irradiated mouse neuroblastoma cells infected with street or laboratory strains of rabies virus. Bound rabies-specific antibody was detected by reaction with horseradish peroxidase-labeled goat anti-mouse immunoglobulin G. The assay was performed in a 96-well filtration device developed by Cleveland et al. (J. Clin. Microbiol. ...

  14. A High-Performance Fluorescence Immunoassay Based on the Relaxation of Quenching, Exemplified by Detection of Cardiac Troponin I

    Directory of Open Access Journals (Sweden)

    Seung-Wan Kim

    2016-05-01

    Full Text Available The intramolecular fluorescence self-quenching phenomenon is a major drawback in developing high-performance fluorometric biosensors which use common fluorophores as signal generators. We propose two strategies involving liberation of the fluorescent molecules by means of enzymatic fragmentation of protein or dehybridization of double-stranded DNA. In the former, bovine serum albumin (BSA was coupled with the fluorescent BODIPY dye (Red BSA, and then immobilized on a solid surface. When the insolubilized Red BSA was treated with proteinase K (10 units/mL for 30 min, the fluorescent signal was significantly increased (3.5-fold compared to the untreated control. In the second case, fluorophore-tagged DNA probes were linked to gold nanoparticles by hybridization with capture DNA strands densely immobilized on the surface. The quenched fluorescence signal was recovered (3.7-fold by thermal dehybridization, which was induced with light of a specific wavelength (e.g., 530 nm for less than 1 min. We next applied the Red BSA self-quenching relaxation technique employing enzymatic fragmentation to a high-performance immunoassay of cardiac troponin I (cTnI in a microtiter plate format. The detection limit was 0.19 ng/mL cTnI, and the fluorescent signal was enhanced approximately 4.1-fold compared with the conventional method of direct measurement of the fluorescent signal from a non-fragmented fluorophore-labeled antibody.

  15. A sandwich-type electrochemical immunoassay for ultrasensitive detection of non-small cell lung cancer biomarker CYFRA21-1.

    Science.gov (United States)

    Zeng, Yan; Bao, Jing; Zhao, Yanan; Huo, Danqun; Chen, Mei; Qi, Yanli; Yang, Mei; Fa, Huanbao; Hou, Changjun

    2018-04-01

    Many studies confirm that the aberrant expression of Cytokeratin 19 fragment 21-1 (CYFRA21-1) is highly correlated with non-small cell lung cancer (NSCLC), especially for squamous cell carcinoma. Herein, we report a sandwich-type electrochemical immunosensor based on signal amplification strategy of multiple nanocomposites to test CYFRA21-1 selectively and sensitively. The proposed immunosensor fabricated by three-dimensional graphene (3D-G), chitosan (CS) and glutaraldehyde (GA) composite on the glass carbon electrode (GCE) with a large surface area is prepared to immobilize primary antibodies (Ab 1 ) and provide excellent conductivity. To further amplify the electrochemical signal, the trace tag on the foundation of gold nanoparticles (AuNPs) is coated with amino-functionalized carbon nanotube (MWCNT-NH 2 ) nanocomposite through thionine linking, which provides more amino groups to capture more horseradish peroxidase-labeled antibodies (HPR-Ab 2 ) and enhances the conductivity. Under optimal conditions, the developed immunosensor exhibits excellent analytical performance for the determination of CYFRA21-1 with a wide linear range from 0.1 to 150ng·mL -1 and a low detection limit (LOD) of 43pg·mL -1 . Furthermore, satisfactory results are obtained for the determination of CYFRA21-1 in real clinical serum samples, indicating the potential of the immunoassay to be applied in clinical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Multiplex competitive microbead-based flow cytometric immunoassay using quantum dot fluorescent labels

    International Nuclear Information System (INIS)

    Yu, Hye-Weon; Kim, In S.; Niessner, Reinhard; Knopp, Dietmar

    2012-01-01

    Highlights: ► First time, duplex competitive bead-based flow cytometric immunoassay was developed using ODs. ► Antibody-coated QD detection probes and antigen-immobilized microspheres were synthesized. ► The two model target analytes were low molecular weight compounds of microbial and chemical origin. ► The determination of different water types was possible after simple filtration of samples. - Abstract: In answer to the ever-increasing need to perform the simultaneous analysis of environmental hazards, microcarrier-based multiplex technologies show great promise. Further integration with biofunctionalized quantum dots (QDs) creates new opportunities to extend the capabilities of multicolor flow cytometry with their unique fluorescence properties. Here, we have developed a competitive microbead-based flow cytometric immunoassay using QDs fluorescent labels for simultaneous detection of two analytes, bringing the benefits of sensitive, rapid and easy-of-manipulation analytical tool for environmental contaminants. As model target compounds, the cyanobacterial toxin microcystin-LR and the polycyclic aromatic hydrocarbon compound benzo[a]pyrene were selected. The assay was carried out in two steps: the competitive immunological reaction of multiple targets using their exclusive sensing elements of QD/antibody detection probes and antigen-coated microsphere, and the subsequent flow cytometric analysis. The fluorescence of the QD-encoded microsphere was thus found to be inversely proportional to target analyte concentration. Under optimized conditions, the proposed assay performed well within 30 min for the identification and quantitative analysis of the two environmental contaminants. For microcystin-LR and benzo[a]pyrene, dose–response curves with IC 50 values of 5 μg L −1 and 1.1 μg L −1 and dynamic ranges of 0.52–30 μg L −1 and 0.13–10 μg L −1 were obtained, respectively. Recovery was 92.6–106.5% for 5 types of water samples like bottled

  17. Immunoassay for serum amyloid A using a glassy carbon electrode modified with carboxy-polypyrrole, multiwalled carbon nanotubes, ionic liquid and chitosan

    International Nuclear Information System (INIS)

    Xia, Chunyong; Li, Yuan; Yuan, Guolin; Guo, Yanlei; Yu, Chao

    2015-01-01

    We report on a highly sensitive electrochemical immunoassay for the serum inflammation marker amyloid A (SAA). It is making use of a glassy carbon electrode that was modified with carboxy-endcapped polypyrrole (PPy-α-COOH), multiwalled carbon nanotubes (MWCNTs), ionic liquid and chitosan acting as the support platform. The nanocomposite increases the sensitivity and stability of the assay. Antibody against SAA was immobilized on a monolayer surface consisting of PPy-α-COOH. The electrode material was characterized by scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectra, cyclic voltammetry, electrochemical impedance spectroscopy and differential pulse voltammetry. The calibration plot for this assay, when operated at 0.16 V (vs. SCE) and applied to spiked serum samples, is linear in the 0.001 to 900 ng mL −1 SAA concentration range, and the detection limit is as low as 0.3 pg mL −1 (at an S/N ratio of 3). The electrode is stable and highly sensitive. The detection scheme is likely to be applicable to numerous other kinds of immunoassays. (author)

  18. Composite poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex for immunoassay. The case of plasminogen.

    Science.gov (United States)

    Miksa, B; Wilczynska, M; Cierniewski, C; Basinska, T; Slomkowski, S

    1995-01-01

    Poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex (ACRYLAT) was synthesized by radical precipitation polymerization. The mass median diameter (MMD) and the geometrical standard deviation (GSD) of the ACRYLAT particles were 138 nm and 1.2, respectively. The concentration of the titrable carboxylic groups in the surface layer of latex particles was equal to 8.41 x 10(-6) mol m-2. Latex was able to bind up to 2.82 x 10(-7) mol of 1-aminopyrene per 1 m2 of the surface of the latex particles due to the ionic interactions between carboxylate anions and ammonium cations of protonated 1-aminopyrene. ACRYLAT was able to immobilize covalently human serum albumin in amounts up to 0.23 mg m-2. Aggregation of ACRYLAT with immobilized HSA, induced with specific antibodies (anti-HSA), was investigated turbidimetrically. The results indicated that in the model turbidimetric immunoassay, ACRYLAT coated with HSA can be used for the detection of anti-HSA in the goat anti-HSA serum diluted from 50 to 7000-fold. Immobilization of rabbit antibodies to plasminogen (anti-Plg) to ACRYLAT via the epsilon-aminocaproic acid linkers provided particles which were used for the development of the turbidimetric immunoassay for plasminogen. In this assay plasminogen could be detected in concentration ranging from 0.75 to 75 micrograms ml-1 in the blood plasma.

  19. Preparation by irradiation of a solid support for enzyme immunoassay

    International Nuclear Information System (INIS)

    Kumakura, M.; Kaetsu, I.

    1984-01-01

    Reagents (immobilized anti-α-fetoprotein discs) having a porous structure were prepared for enzyme immunoassay of α-fetoprotein by radiation polymerization at low temperatures. Discs were attached to sticks for easy handling. The activity (determined by absorbance at 492 nm) of the discs varied with the hydrophilic properties and size of the discs. The discs are sufficiently sensitive and precise for enzyme immunoassay of α-fetoprotein. Anti-AFP dissolved in PBS solution was mixed with a monomer solution of hydroxyethyl methacrylate and hydroxypropyl methacrylate. The mixture was frozen to -78 0 C and gamma irradiated. (Auth.)

  20. Serum gastrin: interests and limitations of radio-immunoassay

    International Nuclear Information System (INIS)

    Rougier, P.; Linhart, N.; Bok, B.

    1980-01-01

    Radio-immunoassay of serum gastrin may now be carried out in all laboratories of radio-immunology. Comparison of two commercial kits A: Schwartz-Mann and B: CEA-SORIN according to criteria of specificity, sensitivity and reproducibility within and between systems, shows that they both permit the detection of pathological hypergastrinemias (Zollinger Ellison and atropic gastritis). Both kits have an identical intrasystem coefficient of variation (10 p. cent and 7 p. cent fort A, 5 p. cent and 8 p. cent for B) on the other hand, the inter-system coefficient of variation is better for kit B (22.4 p. cent and 37 p. cent for kit A, and 11.5 p. cent and 14.2 p. cent for kit B). The normal values for each kit are quite different: 97 . 64 pg.ml -1 for A and 51 . 23 pg.ml -1 for B preventing one from comparing estimations carried out with two different kits [fr

  1. Detection of Campylobacter in Stool and Determination of Significance by Culture, Enzyme Immunoassay, and PCR in Developing Countries

    Science.gov (United States)

    Platts-Mills, James A.; Liu, Jie; Gratz, Jean; Mduma, Esto; Amour, Caroline; Swai, Ndealilia; Taniuchi, Mami; Begum, Sharmin; Peñataro Yori, Pablo; Tilley, Drake H.; Lee, Gwenyth; Shen, Zeli; Whary, Mark T.; Fox, James G.; McGrath, Monica; Kosek, Margaret; Haque, Rashidul

    2014-01-01

    Campylobacter is a common bacterial enteropathogen that can be detected in stool by culture, enzyme immunoassay (EIA), or PCR. We compared culture for C. jejuni/C. coli, EIA (ProSpecT), and duplex PCR to distinguish Campylobacter jejuni/C. coli and non-jejuni/coli Campylobacter on 432 diarrheal and matched control stool samples from infants in a multisite longitudinal study of enteric infections in Tanzania, Bangladesh, and Peru. The sensitivity and specificity of culture were 8.5% and 97.6%, respectively, compared with the results of EIA and 8.7% and 98.0%, respectively, compared with the results of PCR for C. jejuni/C. coli. Most (71.6%) EIA-positive samples were positive by PCR for C. jejuni/C. coli, but 27.6% were positive for non-jejuni/coli Campylobacter species. Sequencing of 16S rRNA from 53 of these non-jejuni/coli Campylobacter samples showed that it most closely matched the 16S rRNA of C. hyointestinalis subsp. lawsonii (56%), C. troglodytis (33%), C. upsaliensis (7.7%), and C. jejuni/C. coli (2.6%). Campylobacter-negative stool spiked with each of the above-mentioned Campylobacter species revealed reactivity with EIA. PCR detection of Campylobacter species was strongly associated with diarrhea in Peru (odds ratio [OR] = 3.66, P < 0.001) but not in Tanzania (OR = 1.56, P = 0.24) or Bangladesh (OR = 1.13, P = 0.75). According to PCR, Campylobacter jejuni/C. coli infections represented less than half of all infections with Campylobacter species. In sum, in infants in developing country settings, the ProSpecT EIA and PCR for Campylobacter reveal extremely high rates of positivity. We propose the use of PCR because it retains high sensitivity, can ascertain burden, and can distinguish between Campylobacter infections at the species level. PMID:24452175

  2. Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.

    Science.gov (United States)

    Gelpí, Carmen; Pérez, Elena; Roldan, Cristina

    2014-09-01

    The aim of this study was to compare the degree of agreement of a novel Zenit RA chemiluminescent immunoassay (CLIA) from A. Menarini Diagnostics (Florence, Italy) and the gold standard immunoprecipitation assay to screen for the presence of specific anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl-70(Topo I) antibodies. We studied 114 sera, 98 from patients with well-defined autoimmune connective tissue diseases and 16 from blood donor volunteers. All samples were fully characterized using the new chemiluminescent immunoassay and immunoprecipitation. In addition, all the samples were analyzed by indirect immunofluorescence (IIF) and anti-Scl-70(Topo I) antibodies were analyzed by immunoblot (IB) assay. Discrepant samples were analyzed using a commercial dot blot technique (Recomline from Mikrogen). The simple Kappa coefficient was used to measure the level of agreement between the results of Zenit RA CLIA and the gold standard. The Kappa agreement between Zenit RA CLIA and gold standard immunoprecipitation, as well as IB and IIFassays for the presence of anti-Scl-70(Topo I)(0.948) was excellent. The concordance between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-U1snRNP (0.883), anti-Ro/SS-A (0.878), anti-Jo-1((his)tRNA-Synthetase) (0.791) and anti-Sm (0.786) was good, and excellent when the cut-off was raised to 14 U/ml (arbitrary units/ml). Between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-La/SS-B, the Kappa agreement had a value of 0.689, but this improved to 0.775 when the cut-off was raised to14 U/ml. Precision was good based on the evaluation of replicate samples. Inter-assay coefficient variation was lower than 3.4 % (CV in %) in all the kits and <1.2 % (CV in  %) for intra-assay measurements. Our findings show that Zenit RA CLIA was specific and sensitive to detect anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his

  3. One-step synthesis of redox-active polymer/AU nanocomposites for electrochemical immunoassay of multiplexed tumor markers.

    Science.gov (United States)

    Liu, Zhimin; Rong, Qinfeng; Ma, Zhanfang; Han, Hongliang

    2015-03-15

    In this work, a simple and sensitive multiplexed immunoassay protocol for simultaneous electrochemical determination of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) was designed using redox-active nanocomposites. As the redox-active species, the poly(o-phenylenediamine) (POPD)/Au nanocomposite and poly(vinyl ferrocene-2-aminothiophenol) (poly(VFc-ATP))/Au nanocomposite were obtained by one-step method which HAuCl4 was used as the oxidant. With Au nanoparticles (AuNPs), the nanocomposites were successful to immobilize labeled anti-CEA and anti-AFP as the immunosensing probes. The proposed electrochemical immunoassay enabled the simultaneous monitoring of AFP and CEA in a wide range of 0.01-100ngmL(-1). The detection limits was 0.006ngmL(-1) for CEA and 0.003ngmL(-1) for AFP (S/N=3). The assay results of serum samples with the proposed method were well consistent with the reference values from standard ELISA method. And the negligible cross-reactivity between the two analytes makes it possesses potential promise in clinical diagnosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Sensitive targeted multiple protein quantification based on elemental detection of Quantum Dots

    Energy Technology Data Exchange (ETDEWEB)

    Montoro Bustos, Antonio R.; Garcia-Cortes, Marta [Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, Oviedo 33006 (Spain); González-Iglesias, Hector [Fundación de Investigación Oftalmológica, Instituto Oftalmológico Fernandez-Vega, Avenida Doctores Fernández-Vega, 34, Oviedo 33012 (Spain); Ruiz Encinar, Jorge, E-mail: ruizjorge@uniovi.es [Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, Oviedo 33006 (Spain); Costa-Fernández, José M. [Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, Oviedo 33006 (Spain); Coca-Prados, Miguel [Fundación de Investigación Oftalmológica, Instituto Oftalmológico Fernandez-Vega, Avenida Doctores Fernández-Vega, 34, Oviedo 33012 (Spain); Department of Ophthalmology and Visual Science, Yale University School of Medicine, New Haven, CT 06510 (United States); Sanz-Medel, Alfredo, E-mail: asm@uniovi.es [Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, Oviedo 33006 (Spain)

    2015-06-16

    Highlights: • Novel generic platform for multiparametric quantification of proteins. • QDs labeling and ICP-MS detection allow significant analytical signal amplification. • ICP-MS mass balances information provided an internal validation of the immunoassay. • Multiparametric determination of 5 proteins in human serum samples. • ICP-MS reduced matrix effects as compared to other conventional detection techniques. - Abstract: A generic strategy based on the use of CdSe/ZnS Quantum Dots (QDs) as elemental labels for protein quantification, using immunoassays with elemental mass spectrometry (ICP-MS), detection is presented. In this strategy, streptavidin modified QDs (QDs-SA) are bioconjugated to a biotinylated secondary antibody (b-Ab{sub 2}). After a multi-technique characterization of the synthesized generic platform (QDs-SA-b-Ab{sub 2}) it was applied to the sequential quantification of five proteins (transferrin, complement C3, apolipoprotein A1, transthyretin and apolipoprotein A4) at different concentration levels in human serum samples. It is shown how this generic strategy does only require the appropriate unlabeled primary antibody for each protein to be detected. Therefore, it introduces a way out to the need for the cumbersome and specific bioconjugation of the QDs to the corresponding specific recognition antibody for every target analyte (protein). Results obtained were validated with those obtained using UV–vis spectrophotometry and commercial ELISA Kits. As expected, ICP-MS offered one order of magnitude lower DL (0.23 fmol absolute for transferrin) than the classical spectrophotometric detection (3.2 fmol absolute). ICP-MS precision and detection limits, however turned out to be compromised by procedural blanks. The full analytical performance of the ICP-MS-based immunoassay proposed was assessed for detection of transferrin (Tf), present at the low ng mL{sup −1} range in a complex “model” synthetic matrix, where the total protein

  5. Protein detection using biobarcodes.

    Science.gov (United States)

    Müller, Uwe R

    2006-10-01

    Over the past 50 years the development of assays for the detection of protein analytes has been driven by continuing demands for higher levels of sensitivity and multiplexing. The result has been a progression of sandwich-type immunoassays, starting with simple radioisotopic, colorimetric, or fluorescent labeling systems to include various enzymatic or nanostructure-based signal amplification schemes, with a concomitant sensitivity increase of over 1 million fold. Multiplexing of samples and tests has been enabled by microplate and microarray platforms, respectively, or lately by various molecular barcoding systems. Two different platforms have emerged as the current front-runners by combining a nucleic acid amplification step with the standard two-sided immunoassay. In both, the captured protein analyte is replaced by a multiplicity of oligonucleotides that serve as surrogate targets. One of these platforms employs DNA or RNA polymerases for the amplification step, while detection is by fluorescence. The other is based on gold nanoparticles for both amplification as well as detection. The latter technology, now termed Biobarcode, is completely enzyme-free and offers potentially much higher multiplexing power.

  6. System-on-fluidics immunoassay device integrating wireless radio-frequency-identification sensor chips.

    Science.gov (United States)

    Yazawa, Yoshiaki; Oonishi, Tadashi; Watanabe, Kazuki; Shiratori, Akiko; Funaoka, Sohei; Fukushima, Masao

    2014-09-01

    A simple and sensitive point-of-care-test (POCT) device for chemiluminescence (CL) immunoassay was devised and tested. The device consists of a plastic flow-channel reactor and two wireless-communication sensor chips, namely, a photo-sensor chip and a temperature-sensor chip. In the flow-channel reactor, a target antigen is captured by an antibody immobilized on the inner wall of the flow-channel and detected with enzyme labeled antibody by using CL substrate. The CL signal corresponding to the amount of antigen is measured by a newly developed radio-frequency-identification (RFID) sensor, which enables batteryless operation and wireless data communication with an external reader. As for the POCT device, its usage environment, especially temperature, varies for each measurement. Hence, temperature compensation is a key issue in regard to eliminating dark-signal fluctuation, which is a major factor in deterioration of the precision of the POCT device. A two-stage temperature-compensation scheme was adopted. As for the first stage, the signals of two photodiodes, one with an open window and one with a sealed window, integrated on the photo-sensor chip are differentiated to delete the dark signal. As for the second stage, the differentiated signal fluctuation caused by a temperature variation is compensated by using the other sensor chip (equipped with a temperature sensor). The dark-level fluctuation caused by temperature was reduced from 0.24 to 0.02 pA/°C. The POCT device was evaluated as a CL immunoassay of thyroid-stimulating hormone (TSH). The flow rate of the CL reagent in the flow channel was optimized. As a result, the detection limit of the POCT device was 0.08 ng/ml (i.e., 0.4 μIU/ml). Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  7. Utilization of a DNA enzyme immunoassay for the detection of proviral DNA of human immunodeficiency virus type 1 by polymerase chain reaction.

    Science.gov (United States)

    Zella, D; Cavicchini, A; Cattaneo, E; Cimarelli, A; Bertazzoni, U

    1995-02-01

    The detection of proviral DNA by Polymerase Chain Reaction (PCR) is regarded as an important tool in the diagnosis of HIV-1 infection, specially among adults at risk of AIDS and children born to seropositive mothers. However, application of PCR in routine testing is hampered by the need to use radioactive probes. In this study, a non-radioactive test based on a microtiter plate (DNA Enzyme ImmunoAssay, DEIA) was used for the detection of proviral sequences of HIV-1 in peripheral blood cells of different patients. The results of the PCR-DEIA assay were compared to those obtained by liquid hybridization (PCR-LH), virus isolation (VI) and Western blot (WB). The study population included 92 patients belonging to three different groups: seropositive subjects with a well-defined clinical status and WB profile; adults at risk of infection with negative or indeterminate WB; children born to seropositive mothers with still unestablished HIV-1 infection. In the seropositive subjects, both PCR-LH and PCR-DEIA confirmed infection and gave the same results as WB. In adults at risk of infection, PCR with both methods anticipated the seroconversion in one patient with indeterminate WB and confirmed the absence of infection among seronegative and other indeterminate patients. In children born to seropositive mothers, both PCR systems as well as VI permitted an early diagnosis of infection, as confirmed by the clinical follow-up. This study has shown that in subjects at risk of AIDS and in children born to seropositive mothers, the non-isotopic DEIA method presents the same sensitivity and specificity for the detection of HIV-1 infection as the radioactive procedure. The DEIA method appears to be particularly useful for the detection of PCR products in routine diagnostic analyses.

  8. Comparison of pre-processing methods for multiplex bead-based immunoassays.

    Science.gov (United States)

    Rausch, Tanja K; Schillert, Arne; Ziegler, Andreas; Lüking, Angelika; Zucht, Hans-Dieter; Schulz-Knappe, Peter

    2016-08-11

    High throughput protein expression studies can be performed using bead-based protein immunoassays, such as the Luminex® xMAP® technology. Technical variability is inherent to these experiments and may lead to systematic bias and reduced power. To reduce technical variability, data pre-processing is performed. However, no recommendations exist for the pre-processing of Luminex® xMAP® data. We compared 37 different data pre-processing combinations of transformation and normalization methods in 42 samples on 384 analytes obtained from a multiplex immunoassay based on the Luminex® xMAP® technology. We evaluated the performance of each pre-processing approach with 6 different performance criteria. Three performance criteria were plots. All plots were evaluated by 15 independent and blinded readers. Four different combinations of transformation and normalization methods performed well as pre-processing procedure for this bead-based protein immunoassay. The following combinations of transformation and normalization were suitable for pre-processing Luminex® xMAP® data in this study: weighted Box-Cox followed by quantile or robust spline normalization (rsn), asinh transformation followed by loess normalization and Box-Cox followed by rsn.

  9. Highly sensitive electrochemical immunoassay for human IgG using double-encoded magnetic redox-active nanoparticles

    International Nuclear Information System (INIS)

    Tang, D.; Tang, J.; Su, B.; Chen, H.; Chen, G.; Huang, J.

    2010-01-01

    A new sandwich-type electrochemical immunoassay was developed for the detection of human IgG using doubly-encoded and magnetic redox-active nanoparticles as recognition elements on the surface of a glassy carbon electrode modified with anti-IgG on nanogold particles. The recognition elements were synthesized by coating magnetic Fe3O4 nanoparticles with Prussian blue nanoparticles and then covered with peroxidase-labeled anti-IgG antibodies (POx-anti-IgG) on Prussian blue nanoparticles. The immunoelectrode displays very good electrochemical properties towards detection of IgG via using double-encoded magnetic redox-active nanoparticles as trace and hydrogen peroxide as enzyme substrate. Its limit of detection (10 pmol.L -1 ) is 10-fold better than that of using plain POx-anti-IgG secondary antibodies. The method was applied to the detection of IgG in serum samples, and an excellent correspondence with the reference values was found. (author)

  10. Comparison of antigen detection and quantitative PCR in the detection of chlamydial infection in koalas (Phascolarctos cinereus).

    Science.gov (United States)

    Hanger, Jon; Loader, Joanne; Wan, Charles; Beagley, Kenneth W; Timms, Peter; Polkinghorne, Adam

    2013-03-01

    The gold standard method for detecting chlamydial infection in domestic and wild animals is PCR, but the technique is not suited to testing animals in the field when a rapid diagnosis is frequently required. The objective of this study was to compare the results of a commercially available enzyme immunoassay test for Chlamydia against a quantitative Chlamydia pecorum-specific PCR performed on swabs collected from the conjunctival sac, nasal cavity and urogenital sinuses of naturally infected koalas (Phascolarctos cinereus). The level of agreement for positive results between the two assays was low (43.2%). The immunoassay detection cut-off was determined as approximately 400 C. pecorum copies, indicating that the test was sufficiently sensitive to be used for the rapid diagnosis of active chlamydial infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Feasibility of a simple microsieve-based immunoassay platform

    NARCIS (Netherlands)

    Zweitzig, D.R.; Tibbe, Arjan G.J.; Nguyen, A.T.; van Rijn, C.J.M.; Kopnitsky, M.J.; Cichonski, K.; Terstappen, Leonardus Wendelinus Mathias Marie

    2016-01-01

    The intrinsic properties of silicon microsieves, such as an optically flat surface, high overall porosity, and low flow resistance have led to an increasing number of biotechnology applications. In this report, the feasibility of creating a microsieve-based immunoassay platform was explored.

  12. Feasibility of a simple microsieve-based immunoassay platform

    NARCIS (Netherlands)

    Zweitzig, Daniel R.; Tibbe, Arjan G.; Nguyen, Ai T.; Rijn, van Cees J.M.; Kopnitsky, Mark J.; Cichonski, Kathleen; Terstappen, Leon W.M.M.

    2016-01-01

    The intrinsic properties of silicon microsieves, such as an optically flat surface, high overall porosity, and low flow resistance have led to an increasing number of biotechnology applications. In this report, the feasibility of creating a microsieve-based immunoassay platform was explored.

  13. Study on the determination of human placental lactogen (HPL) using an enzyme-immunoassay. Comparison with a commercial radio-immunoassay in the course of normal pregnancies

    International Nuclear Information System (INIS)

    Schneider, B.

    1982-01-01

    A novel enzyme-immunoassay (EIA) for determining human placental lactogen (HPL) was studied for its practicability and quality. The precision of the system in series was tested by using a serum taken each in the 19th, 29th and 40th pregnancy week. A normal range graph between the 10th and the 40th pregnancy week (10 sera per pregnancy week) was established from 310 sera of normal-course pregnancies. The graph practically agreed with the known RIA-established graphs. When comparing with a radio-immunoassay for HPL of routine application and known quality criteria, r=0.93 indicated a close correlation of the values found. (orig./MG) [de

  14. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals

    International Nuclear Information System (INIS)

    Zhao Hongwei; Nan Tiegui; Tan Guiyu; Gao Wei; Cao Zhen; Sun Shuo; Li Zhaohu; Li, Qing X.; Wang Baomin

    2011-01-01

    Highlights: · Two highly sensitive immunoassays for determination of Cu(II) at sub ppb levels. · The heterologous competitive enzyme linked immunosorbent assay for heavy metals. · Haptenated protein directly conjugated with HRP can reduce the loss of HRP activity. - Abstract: Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.

  15. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Hongwei [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Nan Tiegui; Tan Guiyu; Gao Wei; Cao Zhen; Sun Shuo; Li Zhaohu [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Li, Qing X., E-mail: qingl@hawaii.edu [Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Wang Baomin, E-mail: wbaomin@263.com [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China)

    2011-09-19

    Highlights: {center_dot} Two highly sensitive immunoassays for determination of Cu(II) at sub ppb levels. {center_dot} The heterologous competitive enzyme linked immunosorbent assay for heavy metals. {center_dot} Haptenated protein directly conjugated with HRP can reduce the loss of HRP activity. - Abstract: Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.

  16. Gastrointestinal symptoms and quality of life in screen-detected celiac disease.

    Science.gov (United States)

    Paavola, Aku; Kurppa, Kalle; Ukkola, Anniina; Collin, Pekka; Lähdeaho, Marja-Leena; Huhtala, Heini; Mäki, Markku; Kaukinen, Katri

    2012-10-01

    Active serological screening has proved an effective means of increasing the diagnostic rate in celiac disease. The effects of a long-term gluten-free diet on possible gastrointestinal symptoms and psychological well-being in screen-detected patients have nevertheless remained obscure. Abdominal symptoms and quality of life were measured in a large cohort of treated screen-detected celiac adults. Comparisons were made with corresponding symptom-detected patients and with non-celiac controls. Dietary adherence was assessed both by structured interview and by serological testing. In both screen- and symptom-detected celiac groups, 88% of the patients were adherent. On a diet, both screen- and symptom-detected patients reported significantly more gastrointestinal symptoms than non-celiac controls. Those screen-detected patients who reported having no symptoms at the time of diagnosis, also remained asymptomatic during the diet. Despite persistent symptoms, psychological well-being in screen-detected patients was comparable with that in non-celiac controls, whereas the symptom-detected patients showed lower quality of life. Long-term treated screen-detected celiac patients, especially women, suffer from gastrointestinal symptoms on a gluten free diet similarly to symptom-detected patients. However, despite a similar frequency of persistent symptoms, the quality of life was unimpaired in the screen found, but remained low in the symptom-detected group. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Current status and future developments in radiolabelled immunoassays

    International Nuclear Information System (INIS)

    Edwards, R.

    1998-01-01

    Radioisotopes are used extensively in medical practice and their use in RIA or IRMA usually represent a small proportion of the total. Radiolabelled immunoassays based on 125 I constitute a simple didactic, cost effective and robust technology which is still regarded as the reference method in many clinical applications. The IAEA has implemented many successful programmes using the ''bulk reagent'' approach, involving 68 countries in all the different regions. The main achievements have been in technology transfer with self sufficiency in production for some countries; training of large numbers of staff; quality control and quality assurance schemes; devolution of screening programmes for neonatal congenital hypothryoidism. Alternatives to the use of radioisotopic tracers are constrained by many factors and are often only available in restricted commercial packages. They are often not suitable for technology transfer programmes and often lack any didactic component in addition to a relative high cost. The production of radiolabels using 125 I is both simple and adaptable. In addition expertise in their preparation and purification is widespread even in developing countries. Together with the ease of producing antibodies, the facts have made 125 I-radiolabelled immunoassays ideal for investigative procedures for many research activities (30,31) particularly in the medical context where radioisotopes are commonly used. In conclusion, even a superficial examination of public health statistics for various countries throughout the continents indicates a need for a simple, inexpensive and robust analytical tool. In this light, there is a predicted continuing role for radiolabelled immunoassays. (author)

  18. Proximity hybridization-regulated catalytic DNA hairpin assembly for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles

    International Nuclear Information System (INIS)

    Zhou, Fuyi; Yao, Yao; Luo, Jianjun; Zhang, Xing; Zhang, Yu; Yin, Dengyang; Gao, Fenglei; Wang, Po

    2017-01-01

    Novel hybridization proximity-regulated catalytic DNA hairpin assembly strategy has been proposed for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles as signal label. The DNA template-synthesized Pd nanoparticles were characterized with atomic force microscopic and X-ray photoelectron spectroscopy. The highly efficient electrocatalysis by DNA template synthesized Pd nanoparticles for NaBH 4 oxidation produced an intense detection signal. The label-free electrochemical method achieved the detection of carcinoembryonic antigen (CEA) with a linear range from 10 −15 to 10 −11  g mL −1 and a detection limit of 0.43 × 10 −15  g mL −1 . Through introducing a supersandwich reaction to increase the DNA length, the electrochemical signal was further amplified, leading to a detection limit of 0.52 × 10 −16  g mL −1 . And it rendered satisfactory analytical performance for the determination of CEA in serum samples. Furthermore, it exhibited good reproducibility and stability; meanwhile, it also showed excellent specificity due to the specific recognition of antigen by antibody. Therefore, the DNA template synthesized Pd nanoparticles based signal amplification approach has great potential in clinical applications and is also suitable for quantification of biomarkers at ultralow level. - Graphical abstract: A novel label-free and enzyme-free electrochemical immunoassay based on proximity hybridization-regulated catalytic DNA hairpin assemblies for recycling of the CEA. - Highlights: • A novel enzyme-free electrochemical immunosensor was developed for detection of CEA. • The signal amplification was based on catalytic DNA hairpin assembly and DNA-template-synthesized Pd nanoparticles. • The biosensor could detect CEA down to 0.52 × 10 −16  g mL −1 level with a dynamic range spanning 5 orders of magnitude.

  19. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  20. A Nanoparticle-Lectin Immunoassay Improves Discrimination of Serum CA125 from Malignant and Benign Sources.

    Science.gov (United States)

    Gidwani, Kamlesh; Huhtinen, Kaisa; Kekki, Henna; van Vliet, Sandra; Hynninen, Johanna; Koivuviita, Niina; Perheentupa, Antti; Poutanen, Matti; Auranen, Annika; Grenman, Seija; Lamminmäki, Urpo; Carpen, Olli; van Kooyk, Yvette; Pettersson, Kim

    2016-10-01

    Measurement of serum cancer antigen 125 (CA125) is the standard approach for epithelial ovarian cancer (EOC) diagnostics and follow-up. However, the clinical specificity is not optimal because increased values are also detected in healthy controls and in benign diseases. CA125 is known to be differentially glycosylated in EOC, potentially offering a way to construct CA125 assays with improved cancer specificity. Our goal was to identify carbohydrate-reactive lectins for discriminating between CA125 originating from EOC and noncancerous sources. CA125 from the OVCAR-3 cancer cell line, placental homogenate, and ascites fluid from patients with cirrhosis were captured on anti-CA125 antibody immobilized on microtitration wells. A panel of lectins, each coated onto fluorescent europium-chelate-doped 97-nm nanoparticles (Eu(+3)-NPs), was tested for detection of the immobilized CA125. Serum samples from high-grade serous EOC or patients with endometriosis and healthy controls were analyzed. By using macrophage galactose-type lectin (MGL)-coated Eu(+3)-NPs, an analytically sensitive CA125 assay (CA125(MGL)) was achieved that specifically recognized the CA125 isoform produced by EOC, whereas the recognition of CA125 from nonmalignant conditions was reduced. Serum CA125(MGL) measurement better discriminated patients with EOC from endometriosis compared to conventional immunoassay. The discrimination was particularly improved for marginally increased CA125 values and for earlier detection of EOC progression. The new CA125(MGL) assay concept could help reduce the false-positive rates of conventional CA125 immunoassays. The improved analytical specificity of this test approach is dependent on a discriminating lectin immobilized in large numbers on Eu(+3)-NPs, providing both an avidity effect and signal amplification. © 2016 American Association for Clinical Chemistry.

  1. Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters.

    Science.gov (United States)

    Shah, Kamal G; Singh, Vidhi; Kauffman, Peter C; Abe, Koji; Yager, Paul

    2018-05-14

    Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.

  2. A Novel Strategy for Detection and Enumeration of Circulating Rare Cell Populations in Metastatic Cancer Patients Using Automated Microfluidic Filtration and Multiplex Immunoassay.

    Directory of Open Access Journals (Sweden)

    Mark Jesus M Magbanua

    Full Text Available Size selection via filtration offers an antigen-independent approach for the enrichment of rare cell populations in blood of cancer patients. We evaluated the performance of a novel approach for multiplex rare cell detection in blood samples from metastatic breast (n = 19 and lung cancer patients (n = 21, and healthy controls (n = 30 using an automated microfluidic filtration and multiplex immunoassay strategy. Captured cells were enumerated after sequential staining for specific markers to identify circulating tumor cells (CTCs, circulating mesenchymal cells (CMCs, putative circulating stem cells (CSCs, and circulating endothelial cells (CECs. Preclinical validation experiments using cancer cells spiked into healthy blood demonstrated high recovery rate (mean = 85% and reproducibility of the assay. In clinical studies, CTCs and CMCs were detected in 35% and 58% of cancer patients, respectively, and were largely absent from healthy controls (3%, p = 0.001. Mean levels of CTCs were significantly higher in breast than in lung cancer patients (p = 0.03. Fifty-three percent (53% of cancer patients harbored putative CSCs, while none were detectable in healthy controls (p<0.0001. In contrast, CECs were observed in both cancer and control groups. Direct comparison of CellSearch® vs. our microfluidic filter method revealed moderate correlation (R2 = 0.46, kappa = 0.47. Serial blood analysis in breast cancer patients demonstrated the feasibility of monitoring circulating rare cell populations over time. Simultaneous assessment of CTCs, CMCs, CSCs and CECs may provide new tools to study mechanisms of disease progression and treatment response/resistance.

  3. A Novel Strategy for Detection and Enumeration of Circulating Rare Cell Populations in Metastatic Cancer Patients Using Automated Microfluidic Filtration and Multiplex Immunoassay.

    Science.gov (United States)

    Magbanua, Mark Jesus M; Pugia, Michael; Lee, Jin Sun; Jabon, Marc; Wang, Victoria; Gubens, Matthew; Marfurt, Karen; Pence, Julia; Sidhu, Harwinder; Uzgiris, Arejas; Rugo, Hope S; Park, John W

    2015-01-01

    Size selection via filtration offers an antigen-independent approach for the enrichment of rare cell populations in blood of cancer patients. We evaluated the performance of a novel approach for multiplex rare cell detection in blood samples from metastatic breast (n = 19) and lung cancer patients (n = 21), and healthy controls (n = 30) using an automated microfluidic filtration and multiplex immunoassay strategy. Captured cells were enumerated after sequential staining for specific markers to identify circulating tumor cells (CTCs), circulating mesenchymal cells (CMCs), putative circulating stem cells (CSCs), and circulating endothelial cells (CECs). Preclinical validation experiments using cancer cells spiked into healthy blood demonstrated high recovery rate (mean = 85%) and reproducibility of the assay. In clinical studies, CTCs and CMCs were detected in 35% and 58% of cancer patients, respectively, and were largely absent from healthy controls (3%, p = 0.001). Mean levels of CTCs were significantly higher in breast than in lung cancer patients (p = 0.03). Fifty-three percent (53%) of cancer patients harbored putative CSCs, while none were detectable in healthy controls (p<0.0001). In contrast, CECs were observed in both cancer and control groups. Direct comparison of CellSearch® vs. our microfluidic filter method revealed moderate correlation (R2 = 0.46, kappa = 0.47). Serial blood analysis in breast cancer patients demonstrated the feasibility of monitoring circulating rare cell populations over time. Simultaneous assessment of CTCs, CMCs, CSCs and CECs may provide new tools to study mechanisms of disease progression and treatment response/resistance.

  4. Microfluidics microFACS for Life Detection

    Science.gov (United States)

    Platt, Donald W.; Hoover, Richard B.

    2010-01-01

    A prototype micro-scale Fluorescent Activated Cell Sorter (microFACS) for life detection has been built and is undergoing testing. A functional miniature microfluidics instrument with the ability to remotely distinguish live or dead bacterial cells from abiotic particulates in ice or permafrost of icy bodies of the solar system would be of fundamental value to NASA. The use of molecular probes to obtain the bio-signature of living or dead cells could answer the most fundamental question of Astrobiology: Does life exist beyond Earth? The live-dead fluorescent stains to be used in the microFACS instrument function only with biological cell walls. The detection of the cell membranes of living or dead bacteria (unlike PAH's and many other Biomarkers) would provide convincing evidence of present or past life. This miniature device rapidly examine large numbers of particulates from a polar ice or permafrost sample and distinguish living from dead bacteria cells and biological cells from mineral grains and abiotic particulates and sort the cells and particulates based on a staining system. Any sample found to exhibit fluorescence consistent with living cells could then be used in conjunction with a chiral labeled release experiment or video microscopy system to seek addition evidence for cellular metabolism or motility. Results of preliminary testing and calibration of the microFACS prototype instrument system with pure cultures and enrichment assemblages of microbial extremophiles will be reported.

  5. A rapid lateral flow immunoassay for the detection of tyrosine phosphatase-like protein IA-2 autoantibodies in human serum.

    Directory of Open Access Journals (Sweden)

    Ingrid Kikkas

    Full Text Available Type 1 diabetes (T1D results from the destruction of pancreatic insulin-producing beta cells and is strongly associated with the presence of islet autoantibodies. Autoantibodies to tyrosine phosphatase-like protein IA-2 (IA-2As are considered to be highly predictive markers of T1D. We developed a novel lateral flow immunoassay (LFIA based on a bridging format for the rapid detection of IA-2As in human serum samples. In this assay, one site of the IA-2As is bound to HA-tagged-IA-2, which is subsequently captured on the anti-HA-Tag antibody-coated test line on the strip. The other site of the IA-2As is bound to biotinylated IA-2, allowing the complex to be visualized using colloidal gold nanoparticle-conjugated streptavidin. For this study, 35 serum samples from T1D patients and 44 control sera from non-diabetic individuals were analyzed with our novel assay and the results were correlated with two IA-2A ELISAs. Among the 35 serum samples from T1D patients, the IA-2A LFIA, the in-house IA-2A ELISA and the commercial IA-2A ELISA identified as positive 21, 29 and 30 IA-2A-positive sera, respectively. The major advantages of the IA-2A LFIA are its rapidity and simplicity.

  6. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    Science.gov (United States)

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Using an aqueous two-phase polymer-salt system to rapidly concentrate viruses for improving the detection limit of the lateral-flow immunoassay.

    Science.gov (United States)

    Jue, Erik; Yamanishi, Cameron D; Chiu, Ricky Y T; Wu, Benjamin M; Kamei, Daniel T

    2014-12-01

    The development of point-of-need (PON) diagnostics for viruses has the potential to prevent pandemics and protects against biological warfare threats. Here we discuss the approach of using aqueous two-phase systems (ATPSs) to concentrate biomolecules prior to the lateral-flow immunoassay (LFA) for improved viral detection. In this paper, we developed a rapid PON detection assay as an extension to our previous proof-of-concept studies which used a micellar ATPS. We present our investigation of a more rapid polymer-salt ATPS that can drastically improve the assay time, and show that the phase containing the concentrated biomolecule can be extracted prior to macroscopic phase separation equilibrium without affecting the measured biomolecule concentration in that phase. We could therefore significantly decrease the time of the diagnostic assay with an early extraction time of just 30 min. Using this rapid ATPS, the model virus bacteriophage M13 was concentrated between approximately 2 and 10-fold by altering the volume ratio between the two phases. As the extracted virus-rich phase contained a high salt concentration which destabilized the colloidal gold indicator used in LFA, we decorated the gold nanoprobes with polyethylene glycol (PEG) to provide steric stabilization, and used these nanoprobes to demonstrate a 10-fold improvement in the LFA detection limit. Lastly, a MATLAB script was used to quantify the LFA results with and without the pre-concentration step. This approach of combining a rapid ATPS with LFA has great potential for PON applications, especially as greater concentration-fold improvements can be achieved by further varying the volume ratio. Biotechnol. Bioeng. 2014;111: 2499-2507. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  8. Single molecule detection, thermal fluctuation and life

    Science.gov (United States)

    YANAGIDA, Toshio; ISHII, Yoshiharu

    2017-01-01

    Single molecule detection has contributed to our understanding of the unique mechanisms of life. Unlike artificial man-made machines, biological molecular machines integrate thermal noises rather than avoid them. For example, single molecule detection has demonstrated that myosin motors undergo biased Brownian motion for stepwise movement and that single protein molecules spontaneously change their conformation, for switching to interactions with other proteins, in response to thermal fluctuation. Thus, molecular machines have flexibility and efficiency not seen in artificial machines. PMID:28190869

  9. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    Science.gov (United States)

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  10. Analytical validation of Gentian NGAL particle-enhanced enhanced turbidimetric immunoassay (PETIA

    Directory of Open Access Journals (Sweden)

    Gian Luca Salvagno

    2017-08-01

    Full Text Available Objectives: This study was designed to validate the analytical performance of the new Gentian particle-enhanced enhanced turbidimetric immunoassay (PETIA for measuring neutrophil gelatinase-associated lipocalin (NGAL in serum samples. Design and methods: Analytical validation of the Gentian NGAL assay was carried out on a Roche Cobas c501 and was based on assessment of limit of blank (LOB, limit of detection (LOD, functional sensitivity, imprecision, linearity and concordance with the BioPorto NGAL test. Results: The LOB and LOD of Gentian NGAL were found to be 3.8 ng/mL and 6.3 ng/mL, respectively. An analytical coefficient of variation (CV of 20% corresponded to a NGAL value of 10 ng/mL. The intra-assay and inter-assay imprecision (CV was between 0.4 and 5.2% and 0.6 and 7.1% and the total imprecision (CV was 3.7%. The linearity was optimal at NGAL concentrations between 37 and 1420 ng/mL (r=1.00; p<0.001. An excellent correlation was observed between values measured with Gentian NGAL and BioPorto NGAL in 74 routine serum samples (r=0.993. The mean percentage bias of the Gentian assay versus the Bioporto assay was +3.1% (95% CI, +1.6% to +4.5%. Conclusions: These results show that Gentian NGAL may be a viable option to other commercial immunoassays for both routine and urgent assessment of serum NGAL. Keywords: Neutrophil gelatinase-associated lipocalin, NGAL, Analytical validation, Acute kidney injury

  11. Sources of variation in an enzyme-linked immunoassay of bluetongue virus in Culicoides variipennis (Diptera: Ceratopogonidae).

    Science.gov (United States)

    Tabachnick, W J; Mecham, J O

    1991-03-01

    An enzyme-linked immunoassay for detecting bluetongue virus in infected Culicoides variipennis was evaluated using a nested analysis of variance to determine sources of experimental error in the procedure. The major source of variation was differences among individual insects (84% of the total variance). Storing insects at -70 degrees C for two months contributed to experimental variation in the ELISA reading (14% of the total variance) and should be avoided. Replicate assays of individual insects were shown to be unnecessary, since variation among replicate wells and plates was minor (2% of the total variance).

  12. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  13. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    Science.gov (United States)

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  14. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    Science.gov (United States)

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  15. Determination of avian influenza A (H9N2) virions by inductively coupled plasma mass spectrometry based magnetic immunoassay with gold nanoparticles labeling

    Science.gov (United States)

    Xiao, Guangyang; Chen, Beibei; He, Man; Shi, Kaiwen; Zhang, Xing; Li, Xiaoting; Wu, Qiumei; Pang, Daiwen; Hu, Bin

    2017-12-01

    Avian influenza viruses are the pathogens of global poultry epidemics, and may even cause the human infections. Here, we proposed a novel inductively coupled plasma mass spectrometry (ICP-MS) based immunoassay with gold nanoparticles (Au NPs) labeling for the determination of H9N2 virions. Magnetic-beads modified with anti-influenza A H9N2 hemagglutinin mono-antibody (mAb-HA) were utilized for the capture of H9N2 virions in complex matrix; and Au NPs conjugated with mAb-HA were employed for the specific labeling of H9N2 virions for subsequent ICP-MS detection. With a sandwich immunoassay strategy, this method exhibited a high specificity for H9N2 among other influenza A virions such as H1N1 and H3N2. Under the optimized conditions, this method could detect as low as 0.63 ng mL- 1 H9N2 virions with the linear range of 2-400 ng mL- 1, the relative standard deviation for seven replicate detections of H9N2 virions was 7.2% (c = 10 ng mL- 1). The developed method was applied for the detection of H9N2 virions in real-world chicken dung samples, and the recovery for the spiking samples was 91.4-116.9%. This method is simple, rapid, sensitive, selective, reliable and has a good application potential for virions detection in real-world samples.

  16. Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection

    DEFF Research Database (Denmark)

    Brock, I; Weldingh, K; Leyten, EM

    2004-01-01

    Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection.Brock I, Weldingh K, Leyten EM, Arend SM, Ravn P, Andersen P. Department of Infectious Disease Immunology, Statens Serum Institute, Artillerivej 5, DK-2300 Copenhagen S, Denmark. The currently used...... method for immunological detection of tuberculosis infection, the tuberculin skin test, has low specificity. Antigens specific for Mycobacterium tuberculosis to replace purified protein derivative are therefore urgently needed. We have performed a rigorous assessment of the diagnostic potential of four...... selected and combined the specific peptide stretches from the four proteins not recognized by M. bovis BCG-vaccinated individuals. These peptide stretches were tested with peripheral blood mononuclear cells obtained from patients with microscopy- or culture-confirmed tuberculosis and from healthy M. bovis...

  17. Optical Detection of Life on Exoplanets

    Science.gov (United States)

    Heap, Sara

    2009-01-01

    We describe what is known about the atmospheric properties (Teff, lob g, [FelH]) and fundamental properties (mass, age, and metal content) of nearby stars and how they influence the habitable zones and habitable eras of these stars. We then take an observer's point of view to assess the ability of optical telescopes to detect photosynthetic or methanogenic life on planets orbiting these stars.

  18. Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay

    Science.gov (United States)

    Serebrennikova, Kseniya; Samsonova, Jeanne; Osipov, Alexander

    2018-06-01

    Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5-10 ng mL-1 with the limit of detection of 0.1 ng mL-1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies).

  19. How to Search for Life by the Detection of Biochemistry

    Science.gov (United States)

    McKay, C. P.; Davila, A.; Sun, H. J.

    2013-12-01

    We consider how to search for life by the detection of biochemistry in three relevance case: 1) in samples returned to Earth, 2) In situ in the organic rich plume of Enceladus, and 3) On Mars, following the discovery of organics. A search for organic biomarkers can address several questions including: 1) Evidence for present or past life, 2) Evidence for a second genesis of life, 3) Hazard assessment for human explorers and sample return and 4) Detection of bioload from Earth. Some useful analogs for the search for organic biomarkers on other worlds include 1) Ancient Earth sediment record, an example of a poorly preserved ancient biochemistry, 2) Modern environments including anoxic Antarctic sediments 3)Extreme cold desert surfaces in the High Antarctic Dry Valleys 4) Extremely dry soils such as the Atacama Desert 5) Evaporites. Sample preparation is a key issue, often unappreciated in past. Illustrated by the interference of perchlorate with organic detection on Viking and SAM.

  20. Ocean Life Detection on Alien Worlds, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is in response to NASA's request for technologies that can enhance the detection of life in alien oceans. As stated in the call, the Technologies for...

  1. Fake news? Biotin interference in thyroid immunoassays.

    Science.gov (United States)

    Koehler, Viktoria F; Mann, Ulrike; Nassour, Ayham; Alexander Mann, W

    2018-05-29

    We report on a 47 year old male patient with multiple sclerosis (MS) presenting in our outpatient neurology clinic in Frankfurt/Main for therapy evaluation. Before change of treatment laboratory investigations were performed. Thyroid function tests (TFTs) with a streptavidin/biotin based immunoassay revealed severe hyperthyroidism with positive thyroid autoantibodies suggestive for Graves' disease. Clinical presentation and thyroid sonography were unremarkable. Due to the discordance between clinical presentation and TFTs, we repeated medical history, in which the patient reported taking high-doses of biotin (300 mg/day) for MS. Recent studies with patients suffering from primary and secondary progressive MS, indicated promising effects of high-dose biotin on MS-related disability. In immunoassays relaying on streptavidin-biotin interaction, biotin intake can cause falsely high or low results. Two weeks after withdrawing biotin, biotin/streptavidin dependant assays showed no longer the biochemical picture of severe hyperthyroidism. Biotin intake should be paused for at least two to five days prior to the use of biotin/streptavidin dependant assays. Alternatively, non-biotin/streptavidin dependant assays (radioimmunoassay, gas chromatography-mass spectrometry/liquid chromatography-mass spectrometry) may be used. Copyright © 2017. Published by Elsevier B.V.

  2. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  3. Detecting tree-like multicellular life on extrasolar planets.

    Science.gov (United States)

    Doughty, Christopher E; Wolf, Adam

    2010-11-01

    Over the next two decades, NASA and ESA are planning a series of space-based observatories to find Earth-like planets and determine whether life exists on these planets. Previous studies have assessed the likelihood of detecting life through signs of biogenic gases in the atmosphere or a red edge. Biogenic gases and the red edge could be signs of either single-celled or multicellular life. In this study, we propose a technique with which to determine whether tree-like multicellular life exists on extrasolar planets. For multicellular photosynthetic organisms on Earth, competition for light and the need to transport water and nutrients has led to a tree-like body plan characterized by hierarchical branching networks. This design results in a distinct bidirectional reflectance distribution function (BRDF) that causes differing reflectance at different sun/view geometries. BRDF arises from the changing visibility of the shadows cast by objects, and the presence of tree-like structures is clearly distinguishable from flat ground with the same reflectance spectrum. We examined whether the BRDF could detect the existence of tree-like structures on an extrasolar planet by using changes in planetary albedo as a planet orbits its star. We used a semi-empirical BRDF model to simulate vegetation reflectance at different planetary phase angles and both simulated and real cloud cover to calculate disk and rotation-averaged planetary albedo for a vegetated and non-vegetated planet with abundant liquid water. We found that even if the entire planetary albedo were rendered to a single pixel, the rate of increase of albedo as a planet approaches full illumination would be comparatively greater on a vegetated planet than on a non-vegetated planet. Depending on how accurately planetary cloud cover can be resolved and the capabilities of the coronagraph to resolve exoplanets, this technique could theoretically detect tree-like multicellular life on exoplanets in 50 stellar systems.

  4. Evaluation and Comparison of Enzyme Immunoassay (Eia and Acid Fast Staining with Confirmation by Immunofluorescent Antibody Assay for Detection of Cryptosporidium Species in Infants and Young Children.

    Directory of Open Access Journals (Sweden)

    D Dorostcar Moghaddam

    2005-01-01

    Full Text Available Introduction: Cryptosporidiosis is prevalent world wide, causing a variety of problems ranging from acute, self-limiting diarrhea to fatal cases in immunocompromised persons, particulary those with acquired immunodeficiency (AIDS. Diagnosis of Cryptosporidium is made by identification of oocysts in stool specimens. The detection is most commonly made by the acid-fast staining method followed by microscopic examination which has low specificity and sensitivity. Material and Methods: In the present study, we evaluated diagnostic utility of a commercially available enzyme immunoassay (EIA, which detects Cryptosporidium-Specific antigen (CSA in 204 unprocessed stool specimens obtained from patients less than 3 years of age. Results: When compared with the routine screening procedure applied in this field study (screening by acid-fast staining and microscopy after concentration of positive results by IFA, both sensitivity and specificity were 98%. Of the 139 specimens negative by microscopy, 13 (9.3% were positive by EIA, 11 of which were confirmed by inhibition with antibody to Cryptosporidia-specific antigen. Conclusion: The EIA is an important tool for identifying Cryptosporidium in fecal specimens in field studies since it is sensitive, specific, simple to use and unaffected by the presence of a preservative.

  5. The management of isolated positive syphilis enzyme immunoassay results in HIV-negative patients attending a sexual health clinic.

    Science.gov (United States)

    Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith

    2016-08-01

    An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.

  6. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Science.gov (United States)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L- 1 and 0.054 μg L- 1 with the relative standard deviations (RSDs, n = 7, c = 5 μg L- 1) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2-50 μg L- 1. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications.

  7. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  9. Direct salivary cortisol radio-immunoassay determination. Clinical applications

    International Nuclear Information System (INIS)

    Simon, C.; Cherfan, J.; Kurtz, F.; Vignon, F.; Schlienger, J.L.; Chabrier, G.

    1987-01-01

    Salivary cortisol levels reflect the biologically active free fraction of blood cortisol. The authors describe the results obtained with the aim of a radio-immunoassay commercial serum cortisol kit, without prealable extraction in different physiological and pathological situations. Salivary cortisol determination appears performant both in nycthemeral studies and in stimulation or freination tests [fr

  10. Novel electrochemical redox-active species: one-step synthesis of polyaniline derivative-Au/Pd and its application for multiplexed immunoassay

    Science.gov (United States)

    Wang, Liyuan; Feng, Feng; Ma, Zhanfang

    2015-11-01

    Electrochemical redox-active species play crucial role in electrochemically multiplexed immunoassays. A one-pot method for synthesizing four kinds of new electrochemical redox-active species was reported using HAuCl4 and Na2PdCl4 as dual oxidating agents and aniline derivatives as monomers. The synthesized polyaniline derivative-Au/Pd composites, namely poly(N-methyl-o-benzenediamine)-Au/Pd, poly(N-phenyl-o-phenylenediamine)-Au/Pd, poly(N-phenyl-p-phenylenediamine)-Au/Pd and poly(3,3’,5,5’-tetramethylbenzidine)-Au/Pd, exhibited electrochemical redox activity at -0.65 V, -0.3 V, 0.12 V, and 0.5 V, respectively. Meanwhile, these composites showed high H2O2 electrocatalytic activity because of the presence of Au/Pd. The as-prepared composites were used as electrochemical immunoprobes in simultaneous detection of four tumor biomarkers (carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA199), carbohydrate antigen 72-4 (CA724), and alpha fetoprotein (AFP)). This immunoassay shed light on potential applications in simultaneous gastric cancer (related biomarkers: CEA, CA199, CA724) and liver cancer diagnosis (related biomarkers: CEA, CA199, AFP). The present strategy to the synthesize redox species could be easily extended to other polymers such as polypyrrole derivatives and polythiophene derivatives. This would be of great significance in the electrochemical detection of more analytes.

  11. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    Science.gov (United States)

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  12. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin, E-mail: binhu@whu.edu.cn

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L{sup −1} and 0.054 μg L{sup −1} with the relative standard deviations (RSDs, n = 7, c = 5 μg L{sup −1}) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2–50 μg L{sup −1}. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications. - Highlights: • 4-Mercaptophenylboronic acid functionalized magnetic beads were prepared and characterized. • ICP-MS based magnetic immunoassay approach was developed for quantification of glycoproteins. • AFP and CEA were quantified simultaneously with Au and Ag NPs as element tags. • The developed method exhibited good selectivity and sensitivity for target glycoproteins.

  13. In Situ Techniques for Life Detection on Mars

    Science.gov (United States)

    Becker, L.; Brinckerhoff, W.; Cotter, R.

    2006-12-01

    The search for organic matter on Mars is rapidly emerging as a result of technological advancements and the study of early "life" on our own planet. As we learned from the Viking missions and the examination of martian meteorites, the criteria for establishing life require the appropriate strategy. One such approach would require careful mapping of the surface from orbit for the selection of the appropriate landing sites, robotic space missions equipped with several life detection in situ techniques for selection of samples, and sample return missions for additional verification of in situ results and laboratory measurements. It may, however, be possible to obtain critical information about the organic matter and associated mineral assemblages present on Mars, in situ, in a single measurement that is both capable of flight and is nondestructive to the sample. We discuss a new multi-source mass spectrometer, `MOMA' (Mars Organic Molecule Analyzer) that incorporates multiple methods of volatilizing and ionizing chemical compounds from intact samples without further processing or manipulation. Moreover, MOMA is capable of detecting a broad range of organics enabling the evaluation of the origin of the organics and the presence of terrestrial contaminants.

  14. Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.

    Science.gov (United States)

    Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H

    2017-01-01

    Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.

  15. Seeking the Tricorder: Report on Workshops on Advanced Technologies for Life Detection

    Science.gov (United States)

    Reiss-Bubenheim, D.; Boston, P. J.; Partridge, H.; Lindensmith, C.; Nadeau, J. L.

    2017-12-01

    There's great excitement about life prospects on icy fluid-containing moons orbiting our Solar System's gas giant planets, newly discovered planet candidates and continuing long-term interest in possible Mars life. The astrobiology/planetary research communities require advanced technologies to explore and study both Solar System bodies and exoplanets for evidence of life. The Tricorder Workshop, held at Ames Research Center May 19-20, 2017, explored technology topics focused on non-invasive or minimally invasive methods for life detection. The workshop goal was to tease out promising ideas for low TRL concepts for advanced life detection technologies that could be applied to the surface and near-subsurface of Mars and Ocean Worlds (such as Europa and Enceladus) dominated by icy terrain. The workshop technology focus centered on mid-to-far term instrument concepts or other enabling technologies (e.g. robotics, machine learning, etc.) primarily for landed missions, which could detect evidence of extant, extinct and/or "weird" life including the notion of "universal biosignatures". Emphasis was placed on simultaneous and serial sample measurements using a suite of instruments and technological approaches with planetary protection in mind. A follow-on workshop, held July 24 at Caltech, sought to develop a generic flowchart of in situ observations and measurements to provide sufficient information to determine if extant life is present in an environment. The process didn't require participant agreement as to definition of extant life, but instead developed agreement on necessary observations and instruments. The flowchart of measurements was designed to maximize the number of simultaneous observations on a single sample where possible, serializing where necessary, and finally dividing it into parts for the most destructive analyses at the end. Selected concepts from the workshops outlined in this poster provide those technology areas necessary to solicit and develop

  16. A sandwich immunoassay for human prolyl 4-hydroxylase using monoclonal antibody

    International Nuclear Information System (INIS)

    Yoshida, Shinichi

    1986-01-01

    Monoclonal antibody was used in a sandwich enzyme immunoassay and in a radioimmunoassay for human serum immunoreactive prolyl 4-hydroxylase. The enzyme immunoassay utilized a monoclonal antibody as a solid phase and horseradish peroxidase-labeled rabbit antibody to human prolyl 4-hydroxylase as a conjugate. Sensitivity was 0.1 ng of enzyme per tube. With a conjugate purified by an enzyme-bound affinity column, sensitivity was increased to 0.01 ng per tube, and linearity was obtained between 0.01 to 30 ng per tube. The radioimmunoassay used a 125 I-labeled rabbit antibody (IgG) as the conjugate. Sensitivity of this technique was 0.4 ng of enzyme per tube. (Auth.)

  17. Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection

    DEFF Research Database (Denmark)

    Brock, I; Weldingh, K; Leyten, EM

    2004-01-01

    Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection.Brock I, Weldingh K, Leyten EM, Arend SM, Ravn P, Andersen P. Department of Infectious Disease Immunology, Statens Serum Institute, Artillerivej 5, DK-2300 Copenhagen S, Denmark. The currently used...... method for immunological detection of tuberculosis infection, the tuberculin skin test, has low specificity. Antigens specific for Mycobacterium tuberculosis to replace purified protein derivative are therefore urgently needed. We have performed a rigorous assessment of the diagnostic potential of four...... recently identified antigens (Rv2653, Rv2654, Rv3873, and Rv3878) from genomic regions that are lacking from the Mycobacterium bovis bacillus Calmette-Guerin (BCG) vaccine strains as well as from the most common nontuberculous mycobacteria. The fine specificity of potential epitopes in these molecules...

  18. Capillary electrochromatography immunoassay for alpha-fetoprotein based on poly(guanidinium ionic liquid) monolithic material.

    Science.gov (United States)

    Liu, Cuicui; Deng, Qiliang; Fang, Guozhen; Dang, Meng; Wang, Shuo

    2017-08-01

    Alpha-fetoprotein (AFP) is widely used as a tumor marker for the serum diagnosis of primary hepatoma. Sensitive detection of AFP level plays an important role in the early diagnosis of disease and highly reliable prediction. In this study, a novel non-competitive immunoassay (IA) based on poly(guanidinium ionic liquid) monolithic material was developed for detecting ultra trace levels of AFP in capillary electrochromatography (CEC) mode. The AFP was mixed with an excess amount of fluorescently labeled antibody. After incubation, the immunocomplex was separated from the free labeled antibody and detected by CEC coupled with laser-induced fluorescence detector. Under the optimized conditions, the developed CEC-IA performed a low detection limit of 0.05 μg L -1  (S/N = 3) and a wide linearity ranging from 0.1 to 1000 μg L -1 for AFP, which can be largely attributed to the high separation and enrichment efficiency of poly(guanidinium ionic liquid) monolithic material for the targets. The application of this method was demonstrated by determining AFP in human serum. Copyright © 2017. Published by Elsevier Inc.

  19. Immunoassay of β-endorphin

    International Nuclear Information System (INIS)

    Hoellt, V.; Gramsch, C.; Herz, A.

    1979-01-01

    The present paper describes the characteristics of a series of antisera against β-endorphin (β-E) developed in our laboratory which all recognize β-lipotropin and their use in (1) the determination of β-E in tissue and in body fluids and in (2) the immunocytochemical localization of β-E containing neurons in the rat brain and in (3) the study of the conversion of the β-E/β-LPH precursor into β-LPH and β-E in the pars intermedia/nervosa of the rat pituitary. It is the purpose of the present report to critically analyze the pitfalls and drawbacks, as well as the advantage, of the use of radioimmunoassay and other immunoassays in the determination of β-E. (Auth.)

  20. Towards the development of a radioenzyme-immunoassay

    International Nuclear Information System (INIS)

    Schuurs, A.H.W.M.; Waart, M. v. d.

    1976-01-01

    We have tried to develop a very sensitive enzyme-immunoassay. For this purpose, a very sensitive radiochemical enzyme assay was used. HCG was chosen as test model and AChE as labelling enzyme. The test appeared to be much more sensitive than the normal enzymeimmunoassay. And, in comparison with RIA, it was about as sensitive but less time-consuming, and it makes use, in principle, of stable reagents. (orig./GSE) [de

  1. Magnetic Bead Based Immunoassay for Autonomous Detection of Toxins

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Y; Hara, C A; Knize, M G; Hwang, M H; Venkatesteswaran, K S; Wheeler, E K; Bell, P M; Renzi, R F; Fruetel, J A; Bailey, C G

    2008-05-01

    As a step towards toward the development of a rapid, reliable analyzer for bioagents in the environment, we are developing an automated system for the simultaneous detection of a group of select agents and toxins. To detect toxins, we modified and automated an antibody-based approach previously developed for manual medical diagnostics that uses fluorescent eTag{trademark} reporter molecules and is suitable for highly multiplexed assays. Detection is based on two antibodies binding simultaneously to a single antigen, one of which is labeled with biotin while the other is conjugated to a fluorescent eTag{trademark} through a cleavable linkage. Aqueous samples are incubated with the mixture of antibodies along with streptavidin-coated magnetic beads coupled to a photo-activatable porphyrin complex. In the presence of antigen, a molecular complex is formed where the cleavable linkage is held in proximity to the photoactivable group. Upon excitation at 680 nm, free radicals are generated, which diffuse and cleave the linkage, releasing the eTags{trademark}. Released eTags{trademark} are analyzed using capillary gel electrophoresis with laser-induced fluorescence detection. Limits of detection for ovalbumin and botulinum toxoid individually were 4 ng/mL (or 80 pg) and 16 ng/mL (or 320 pg), respectively, using the manual assay. In addition, we demonstrated the use of pairs of antibodies from different sources in a single assay to decrease the rate of false positives. Automation of the assay was demonstrated on a flow-through format with higher LODs of 125 ng/mL (or 2.5 ng) each of a mixture of ovalbumin and botulinum toxoid. This versatile assay can be easily modified with the appropriate antibodies to detect a wide range of toxins and other proteins.

  2. Rapid detection of Avian Influenza Virus - Towards point of care diagnosis

    DEFF Research Database (Denmark)

    Dhumpa, Raghuram

    barcode and fluorescent beads were also developed for rapid detection and identification of the AIV. In both methods, the detection involved sandwiching of the target AIV between monoclonal antibodies for nucleoproteins and for matrix proteins. In the fluorescent DNA barcode-based immunoassay, fluorophore...

  3. Detection of lipomannan in cattle infected with bovine tuberculosis

    Science.gov (United States)

    Early and rapid detection of bovine tuberculosis (bTB) is critical to controlling the spread of this disease in cattle and other animals. In this study, we demonstrate the development of an immunoassay for the direct detection of the bovine bTB biomarker, lipomannan (LM) in serum using a waveguide-...

  4. The clinical application of fluorescent-enzyme immunoassay to detect human thyroid peroxidase autoantibody quantitatively

    International Nuclear Information System (INIS)

    Chai Jinyan; Fang Peihua; Li Ning; Zhang Yanli

    2010-01-01

    Objective: To establish a fluorescent-enzyme immunoassay (FEIA) with recombinant human thyroid peroxidase (hTPO) as the antigen. Methods: Sera of 326 healthy people, 119 cases of Hashimoto's thyroiditis (HT), 116 cases of Graves disease (untreated), 28 cases of nodular goiter, 10 ca-ses of subacute thyroiditis and 6 cases of simple goiter were measured by the FEIA with recombinant hTPO as the antigen. Rrank sum test and χ 2 -test were used in inter-groups. Results: (1) Concentration above 4000 U/L was considered to be positive. (2) The intra-assay coefficient of variation (CV) and the inter-as-say CV were 4.59% ∼ 6.52% and 17.37% ∼ 17.45%. (3) The values measured by the FEIA were positively correlated with the values measured by hTPO antibody (hTPOAb) commercial kit (r=0.80, P 2 = 53.45, 39.30, 15.41 and 21.74, all P < 0.01). Conclusions: The method can be applied in the serum measurement of thyroid disease. HT presented the highest positive rate, therefore, the FEIA was an effective method in diagnosing HT. (authors)

  5. Proximity hybridization-regulated catalytic DNA hairpin assembly for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Fuyi [School of Chemistry and Chemical Engineering, Jiangsu Normal University, Xuzhou 221116 (China); Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Yao, Yao; Luo, Jianjun; Zhang, Xing; Zhang, Yu; Yin, Dengyang [Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Gao, Fenglei, E-mail: jsxzgfl@sina.com [Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Wang, Po, E-mail: wangpo@jsnu.edu.cn [School of Chemistry and Chemical Engineering, Jiangsu Normal University, Xuzhou 221116 (China)

    2017-05-29

    Novel hybridization proximity-regulated catalytic DNA hairpin assembly strategy has been proposed for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles as signal label. The DNA template-synthesized Pd nanoparticles were characterized with atomic force microscopic and X-ray photoelectron spectroscopy. The highly efficient electrocatalysis by DNA template synthesized Pd nanoparticles for NaBH{sub 4} oxidation produced an intense detection signal. The label-free electrochemical method achieved the detection of carcinoembryonic antigen (CEA) with a linear range from 10{sup −15} to 10{sup −11} g mL{sup −1} and a detection limit of 0.43 × 10{sup −15} g mL{sup −1}. Through introducing a supersandwich reaction to increase the DNA length, the electrochemical signal was further amplified, leading to a detection limit of 0.52 × 10{sup −16} g mL{sup −1}. And it rendered satisfactory analytical performance for the determination of CEA in serum samples. Furthermore, it exhibited good reproducibility and stability; meanwhile, it also showed excellent specificity due to the specific recognition of antigen by antibody. Therefore, the DNA template synthesized Pd nanoparticles based signal amplification approach has great potential in clinical applications and is also suitable for quantification of biomarkers at ultralow level. - Graphical abstract: A novel label-free and enzyme-free electrochemical immunoassay based on proximity hybridization-regulated catalytic DNA hairpin assemblies for recycling of the CEA. - Highlights: • A novel enzyme-free electrochemical immunosensor was developed for detection of CEA. • The signal amplification was based on catalytic DNA hairpin assembly and DNA-template-synthesized Pd nanoparticles. • The biosensor could detect CEA down to 0.52 × 10{sup −16} g mL{sup −1} level with a dynamic range spanning 5 orders of magnitude.

  6. Discordant Analytical Results Caused by Biotin Interference on Diagnostic Immunoassays in a Pediatric Hospital.

    Science.gov (United States)

    Ali, Mahesheema; Rajapakshe, Deepthi; Cao, Liyun; Devaraj, Sridevi

    2017-09-01

    Recent studies have reported that biotin interferes with certain immunoassays. In this study, we evaluated the analytical interference of biotin on immunoassays that use streptavidin-biotin in our pediatric hospital. We tested the effect of different concentrations of biotin (1.5-200 ng/ml) on TSH, Prolactin, Ferritin, CK-MB, β-hCG, Troponin I, LH, FSH, Cortisol, Anti-HAV antibody (IgG and IgM), assays on Ortho Clinical Diagnostic Vitros 5600 Analyzer. Biotin (up to 200 ng/mL) did not significantly affect Troponin I and HAV assays. Biotin (up to 12.5 ng/ml) resulted in biotin >6.25 ng/mL significantly affected TSH (>20% bias) assay. Prolactin was significantly affected even at low levels (Biotin 1.5 ng/mL). Thus, we recommend educating physicians about biotin interference in common immunoassays and adding an electronic disclaimer. © 2017 by the Association of Clinical Scientists, Inc.

  7. An Anti-proteome Nanobody Library Approach Yields a Specific Immunoassay for Trypanosoma congolense Diagnosis Targeting Glycosomal Aldolase.

    Directory of Open Access Journals (Sweden)

    Steven Odongo

    2016-02-01

    Full Text Available Infectious diseases pose a severe worldwide threat to human and livestock health. While early diagnosis could enable prompt preventive interventions, the majority of diseases are found in rural settings where basic laboratory facilities are scarce. Under such field conditions, point-of-care immunoassays provide an appropriate solution for rapid and reliable diagnosis. The limiting steps in the development of the assay are the identification of a suitable target antigen and the selection of appropriate high affinity capture and detection antibodies. To meet these challenges, we describe the development of a Nanobody (Nb-based antigen detection assay generated from a Nb library directed against the soluble proteome of an infectious agent. In this study, Trypanosoma congolense was chosen as a model system.An alpaca was vaccinated with whole-parasite soluble proteome to generate a Nb library from which the most potent T. congolense specific Nb sandwich immunoassay (Nb474H-Nb474B was selected. First, the Nb474-homologous sandwich ELISA (Nb474-ELISA was shown to detect experimental infections with high Positive Predictive Value (98%, Sensitivity (87% and Specificity (94%. Second, it was demonstrated under experimental conditions that the assay serves as test-of-cure after Berenil treatment. Finally, this assay allowed target antigen identification. The latter was independently purified through immuno-capturing from (i T. congolense soluble proteome, (ii T. congolense secretome preparation and (iii sera of T. congolense infected mice. Subsequent mass spectrometry analysis identified the target as T. congolense glycosomal aldolase.The results show that glycosomal aldolase is a candidate biomarker for active T. congolense infections. In addition, and by proof-of-principle, the data demonstrate that the Nb strategy devised here offers a unique approach to both diagnostic development and target discovery that could be widely applied to other infectious

  8. Nanoparticle-based immunosensors and immunoassays for aflatoxins

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xu; Niessner, Reinhard [Institute of Hydrochemistry and Chair of Analytical Chemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München (Germany); Tang, Dianping [Key Laboratory of Analysis and Detection for Food Safety, MOE & Fujian Province, Department of Chemistry, Fuzhou University, Fuzhou 350108 (China); Knopp, Dietmar, E-mail: dietmar.knopp@ch.tum.de [Institute of Hydrochemistry and Chair of Analytical Chemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München (Germany)

    2016-03-17

    Aflatoxins are naturally existing mycotoxins produced mainly by Aspergillus flavus and Aspergillus parasiticus, present in a wide range of food and feed products. Because of their extremely high toxicity and carcinogenicity, strict control of maximum residue levels of aflatoxins in foodstuff is set by many countries. In daily routine, different chromatographic methods are used almost exclusively. As supplement, in several companies enzyme immunoassay-based sample testing as primary screening is performed. Recently, nanomaterials such as noble metal nanoparticles, magnetic particles, carbon nanomaterials, quantum dots, and silica nanomaterials are increasingly utilized for aflatoxin determination to improve the sensitivity and simplify the detection. They are employed either as supports for the immobilization of biomolecules or as electroactive or optical labels for signal transduction and amplification. Several nanoparticle-based electrochemical, piezoelectric, optical, and immunodipstick assays for aflatoxins have been developed. In this review, we summarize these recent advances and illustrate novel concepts and promising applications in the field of food safety. - Highlights: • Novel concepts and promising applications of nanoparticle-based immunological methods for the determination of aflatoxins. • Inclusion of most important nanomaterials and hybrid nanostructures. • Inclusion of electrochemical, optical and mass-sensitive biosensors as well as optical and immunochromatographic assays.

  9. Viral RNA testing and automation on the bead-based CBNE detection microsystem.

    Energy Technology Data Exchange (ETDEWEB)

    Galambos, Paul C.; Bourdon, Christopher Jay; Farrell, Cara M.; Rossito, Paul (University of California at Davis); McClain, Jaime L.; Derzon, Mark Steven; Cullor, James Sterling (University of California at Davis); Rahimian, Kamayar

    2008-09-01

    We developed prototype chemistry for nucleic acid hybridization on our bead-based diagnostics platform and we established an automatable bead handling protocol capable of 50 part-per-billion (ppb) sensitivity. We are working towards a platform capable of parallel, rapid (10 minute), raw sample testing for orthogonal (in this case nucleic acid and immunoassays) identification of biological (and other) threats in a single sensor microsystem. In this LDRD we developed the nucleic acid chemistry required for nucleic acid hybridization. Our goal is to place a non-cell associated RNA virus (Bovine Viral Diarrhea, BVD) on the beads for raw sample testing. This key pre-requisite to showing orthogonality (nucleic acid measurements can be performed in parallel with immunoassay measurements). Orthogonal detection dramatically reduces false positives. We chose BVD because our collaborators (UC-Davis) can supply samples from persistently infected animals; and because proof-of-concept field testing can be performed with modification of the current technology platform at the UC Davis research station. Since BVD is a cattle-prone disease this research dovetails with earlier immunoassay work on Botulinum toxin simulant testing in raw milk samples. Demonstration of BVD RNA detection expands the repertoire of biological macromolecules that can be adapted to our bead-based detection. The resources of this late start LDRD were adequate to partially demonstrate the conjugation of the beads to the nucleic acids. It was never expected to be adequate for a full live virus test but to motivate that additional investment. In addition, we were able to reduce the LOD (Limit of Detection) for the botulinum toxin stimulant to 50 ppb from the earlier LOD of 1 ppm. A low LOD combined with orthogonal detection provides both low false negatives and low false positives. The logical follow-on steps to this LDRD research are to perform live virus identification as well as concurrent nucleic acid and

  10. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  11. Monoclonal antibody technologies and rapid detection assays

    Science.gov (United States)

    Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...

  12. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou

    2015-01-01

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL −1 with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO 2 particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors

  13. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou, E-mail: hyhan@mail.hzau.edu.cn

    2015-08-05

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL{sup −1} with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO{sub 2} particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors.

  14. Fluorescently labelled multiplex lateral flow immunoassay based on cadmium-free quantum dots.

    Science.gov (United States)

    Beloglazova, Natalia V; Sobolev, Aleksander M; Tessier, Mickael D; Hens, Zeger; Goryacheva, Irina Yu; De Saeger, Sarah

    2017-03-01

    A sensitive tool for simultaneous qualitative detection of two mycotoxins based on use of non-cadmium quantum dots (QDs) is presented for the first time. QDs have proven themselves as promising fluorescent labels for biolabeling and chemical analysis. With an increasing global tendency to regulate and limit the use of hazardous elements, indium phosphide (InP) QDs are highlighted as environmentally-friendly alternatives to the highly efficient and well-studied, but potentially toxic Cd- and Pb-based QDs. Here, we developed water-soluble InP QDs-based fluorescent nanostructures. They consisted of core/shell InP/ZnS QDs enrobed in a silica shell that allowed the water solubility (QD@SiO 2 ). Then we applied the QD@SiO 2 as novel, silica shell-encapsulated fluorescent labels in immunoassays for rapid multiplexed screening. Two mycotoxins, zearalenone and deoxynivalenol, were simultaneously detected in maize and wheat, since the two QD@SiO 2 labelled conjugates emit at two different, individually detectable wavelengths. The cutoff values for the simultaneous determination were 50 and 500μgkg -1 for zearalenone and deoxynivalenol, respectively, in both maize and wheat. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was used to confirm the result. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Novel photoluminescence enzyme immunoassay based on supramolecular host-guest recognition using L-arginine/6-aza-2-thiothymine-stabilized gold nanocluster.

    Science.gov (United States)

    Wang, Youmei; Lu, Minghua; Tang, Dianping

    2018-06-30

    A new photoluminescence (PL) enzyme immunoassay was designed for sensitive detection of aflatoxin B 1 (AFB 1 ) via an innovative enzyme substrate, 6-aza-2-thiothymine-stabilized gold nanocluster (AAT-AuNC) with L-arginine. The enzyme substrate with strong PL intensity was formed through supramolecular host-guest assembly between guanidine group of L-arginine and AAT capped on the surface of AuNC. Upon arginase introduction, the captured L-arginine was hydrolyzed into ornithine and urea, thus resulting in the decreasing PL intensity. Based on this principle, a novel competitive-type immunoreaction was first carried out on AFB 1 -bovine serum albumin (AFB 1 -BSA) conjugate-coated microplate, using arginase-labeled anti-AFB 1 antibody as the competitor. Under the optimum conditions, the PL intensity increased with the increment of target AFB 1 , and allowed the detection of the analyte at concentrations as low as 3.2 pg mL -1 (ppt). Moreover, L-arginine-AAT-AuNC-based PL enzyme immunoassay afforded good reproducibility and acceptable specificity. In addition, the accuracy of this methodology, referring to commercial AFB 1 ELISA kit, was evaluated to analyze naturally contaminated or spiked peanut samples, giving well-matched results between two methods, thus representing a useful scheme for practical application in quantitative monitoring of mycotoxins in foodstuff. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Life Finder Detectors: An Overview of Detector Technologies for Detecting Life on Other Worlds

    Science.gov (United States)

    Rauscher, Bernard J.; Domagal-Goldman, Shawn; Greenhouse, Matthew A.; Hsieh, Wen-Ting; McElwain, Michael W.; Moseley, Samuel H.; Noroozian, Omid; Norton, Tim; Kutyrev, Alexander; Rinehart, Stephen; stock, Joseph

    2015-01-01

    Future large space telescopes will seek evidence for life on other worlds by searching for spectroscopic biosignatures. Atmospheric biosignature gases include oxygen, ozone, water vapor, and methane. Non-biological gases, including carbon monoxide and carbon dioxide, are important for discriminating false positives. All of these gases imprint spectroscopic features in the UV through mid-IR that are potentially detectable using future space based coronagraphs or star shades for starlight suppression.Direct spectroscopic biosignature detection requires sensors capable of robustly measuring photon arrival rates on the order of 10 per resolution element per hour. Photon counting is required for some wavefront sensing and control approaches to achieve the requisite high contrast ratios. We review life finder detector technologies that either exist today, or are under development, that have the potential to meet these challenging requirements. We specifically highlight areas where more work or development is needed.Life finder detectors will be invaluable for a wide variety of other major science programs. Because of its cross cutting nature; UV, optical, and infrared (UVOIR) detector development features prominently in the 2010 National Research Council Decadal Survey, 'New Worlds, New Horizons in Astronomy and Astrophysics', and the NASA Cosmic Origins Program Technology Roadmap.

  17. Three-dimensional nanoflower-like MnO2 functionalized graphene as catalytically promoted nanolabels for ultrasensitive electrochemiluminescence immunoassay

    International Nuclear Information System (INIS)

    Su, Min; Zhang, Yan; Song, Xianrang; Ge, Shenguang; Yan, Mei; Yu, Jinghua; Huang, Jiadong

    2013-01-01

    A novel electrochemiluminescence (ECL) immunosensor based on the peroxydisulfate solution for detection of prostate-specific antigen (PSA) has been developed. In this work, gold nanoparticles (AuNPs) were electrodeposited on the glassy carbon electrode surface, which could increase the surface area to capture a large amount of primary antibodies as well as to improve the electronic transmission rate. The as-prepared bionanolabels, three-dimensional (3D) nanoflower-like MnO 2 functionalized graphene (GN/MnO 2 ), with novel hybrid architecture were initially fabricated via electrostatic interaction. Then, to provide an effective matrix for antibody immobilization with good stability and bioactivity, the novel materials were modified by AuNPs with the aid of poly (diallyldimethylammonium chloride) via a simple sonication-induced assembly method. In this immunosensor, MnO 2 with the characteristics of well electrochemical behavior, low cost, and environmental-friendly, is used as a substitute for horseradish peroxidase to catalyze H 2 O 2 to produce O 2 , and its 3D nanoflower-like structure is beneficial for the unparallel surface-to-volume ratio. Furthermore, a simple, low-cost and portable home-made potential transformer was utilized in this system to take the place of conventional electrochemical workstation. With a sandwich-type immunoassay format, the amount of functionalized GN/MnO 2 labeled antibodies increased with the increment of antigens in the samples, which implied that the ECL signals enhanced with the increase of in situ generated O 2 due to the enhancive catalysis of MnO 2 to the H 2 O 2 . The immunosensor displayed excellent analytical performance for the detection of PSA in the range of 0.005–10 ng mL −1 with a detection limit of 2.5 pg mL −1 at 3σ. Moreover, the proposed method showed good precision, acceptable stability and reproducibility, and could be used for the detection of PSA in real samples. The proposed method provides a new

  18. Surface biosignatures of exo-earths: remote detection of extraterrestrial life.

    Science.gov (United States)

    Hegde, Siddharth; Paulino-Lima, Ivan G; Kent, Ryan; Kaltenegger, Lisa; Rothschild, Lynn

    2015-03-31

    Exoplanet discovery has made remarkable progress, with the first rocky planets having been detected in the central star's liquid water habitable zone. The remote sensing techniques used to characterize such planets for potential habitability and life rely solely on our understanding of life on Earth. The vegetation red edge from terrestrial land plants is often used as a direct signature of life, but it occupies only a small niche in the environmental parameter space that binds life on present-day Earth and has been widespread for only about 460 My. To more fully exploit the diversity of the one example of life known, we measured the spectral characteristics of 137 microorganisms containing a range of pigments, including ones isolated from Earth's most extreme environments. Our database covers the visible and near-infrared to the short-wavelength infrared (0.35-2.5 µm) portions of the electromagnetic spectrum and is made freely available from biosignatures.astro.cornell.edu. Our results show how the reflectance properties are dominated by the absorption of light by pigments in the visible portion and by strong absorptions by the cellular water of hydration in the infrared (up to 2.5 µm) portion of the spectrum. Our spectral library provides a broader and more realistic guide based on Earth life for the search for surface features of extraterrestrial life. The library, when used as inputs for modeling disk-integrated spectra of exoplanets, in preparation for the next generation of space- and ground-based instruments, will increase the chances of detecting life.

  19. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  20. Immunoassay screening of lysergic acid diethylamide (LSD) and its confirmation by HPLC and fluorescence detection following LSD ImmunElute extraction.

    Science.gov (United States)

    Grobosch, T; Lemm-Ahlers, U

    2002-04-01

    In all, 3872 urine specimens were screened for lysergic acid diethylamide (LSD) using the CEDIA DAU LSD assay. Forty-eight samples, mainly from psychiatric patients or drug abusers, were found to be LSD positive, but only 13 (27%) of these could be confirmed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD) following immunoaffinity extraction (IAE). Additional analysis for LSD using the DPC Coat-a-Count RIA was performed to compare the two immunoassay screening methods. Complete agreement between the DPC RIA assay and HPLC-FLD results was observed at concentrations below a cutoff concentration of 500 pg/mL. Samples that were LSD positive in the CEDIA DAU assay but not confirmed by HPLC-FLD were also investigated for interfering compounds using REMEDI HS drug-profiling system. REMEDI HS analysis identified 15 compounds (parent drugs and metabolites) that are believed to cross-react in the CEDIA DAU LSD assay: ambroxol, prilocaine, pipamperone, diphenhydramine, metoclopramide, amitriptyline, doxepine, atracurium, bupivacaine, doxylamine, lidocaine, mepivacaine, promethazine, ranitidine, and tramadole. The IAE/HPLC-FLD combination is rapid, easy to perform and reliable. It can reduce costs when standard, rather than more advanced, HPLC equipment is used, especially for labs that perform analyses for LSD infrequently. The chromatographic analysis of LSD, nor-LSD, and iso-LSD is not influenced by any of the tested cross-reacting compounds even at a concentration of 100 ng/mL.

  1. Homogenous 96-plex PEA immunoassay exhibiting high sensitivity, specificity, and excellent scalability

    DEFF Research Database (Denmark)

    Assarsson, Erika; Lundberg, Martin; Holmquist, Göran

    2014-01-01

    reporters, shown potential to relieve the shortcomings of antibodies and their inherent cross-reactivity in multiplex protein quantification applications. The aim of the present study was to develop a robust 96-plex immunoassay based on the proximity extension assay (PEA) for improved high throughput...... detection of protein biomarkers. This was enabled by: (1) a modified design leading to a reduced number of pipetting steps compared to the existing PEA protocol, as well as improved intra-assay precision; (2) a new enzymatic system that uses a hyper-thermostabile enzyme, Pwo, for uniting the two probes......, such as serum and plasma, and also in xenografted mice and resuspended dried blood spots, consuming only 1 µL sample per test. All-in-all, the development of the current multiplex technique is a step toward robust high throughput protein marker discovery and research....

  2. Estrogen receptor determination in endometrial carcinoma: ligand binding assay versus enzyme immunoassay

    DEFF Research Database (Denmark)

    Nyholm, H C; Nielsen, Anette Lynge; Lyndrup, J

    1995-01-01

    We compared concentrations of cytosolic estrogen receptors (ERc) measured in 35 postmenopausal endometrial carcinomas by ligand binding method (LBA) (dextran-coated charcoal assay) and enzyme immunoassay (EIA). Correlations between ERc, nuclear estrogen receptors (ERn) determined by EIA......, and cytosolic progesterone receptors (PR) measured by LBA were also studied. While ERc concentrations determined by LBA and EIA were highly correlated (r: 0.94), ERc values detected by LBA were approximately twice those found by EIA (median values of ERc: 155 vs. 64 fmol/mg cytosol protein, DCC vs. EIA......). The percentages of ERc positive tumors were 89% by LBA and 77% by EIA. The median fraction of total ER present as ERn was 63%. PR levels correlated positively with ERn concentrations (r: 0.73). We explore possible reasons why greater concentrations of ERc are determined by estradiol binding than by the ER-EIA kit...

  3. Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement

    DEFF Research Database (Denmark)

    Campbell, Duncan J; Nussberger, Juerg; Stowasser, Michael

    2009-01-01

    into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information...... provided by these assays and of the precautions necessary to ensure their accuracy....

  4. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    Science.gov (United States)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  5. Determination of digoxin by enzyme immunoassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Mueller, H.; Braeuer, H.; Foerster, G.; Reinhardt, M.

    1978-01-01

    The results of parallel determinations of digoxin in the sera of non selected patients (n=104) by enzyme immunoassay (EMIT.EIA) and radioimmunoassay (J-125 labeled RIA) were compared with each other. The determinations revealed considerably different concentrations; the values determined by EIA were statistical lower (for EIA 1,09+'0,99ng/ml, for RIA 1,34+'1,01ng/ml, p [de

  6. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    Science.gov (United States)

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  7. Polyaniline modified flexible conducting paper for cancer detection

    Science.gov (United States)

    Kumar, Saurabh; Sen, Anindita; Kumar, Suveen; Augustine, Shine; Yadav, Birendra K.; Mishra, Sandeep; Malhotra, Bansi D.

    2016-05-01

    We report results of studies relating to the fabrication of a flexible, disposable, and label free biosensing platform for detection of the cancer biomarker (carcinoembryonic antigen, CEA). Polyaniline (PANI) has been electrochemically deposited over gold sputtered paper (Au@paper) for covalent immobilization of monoclonal carcinoembryonic antibodies (anti-CEA). The bovine serum albumin (BSA) has been used for blocking nonspecific binding sites at the anti-CEA conjugated PANI/Au@Paper. The PANI/Au@Paper, anti-CEA/PANI/Au@Paper, and BSA/anti-CEA/PANI/Au@Paper platforms have been characterized using scanning electron microscopy, X-ray diffraction, Fourier transmission infrared spectroscopy, chronoamperometry, and electrochemical impedance techniques. The results of the electrochemical response studies indicate that this BSA/anti-CEA/PANI/Au@paper electrode has sensitivity of 13.9 μA ng-1 ml cm2, shelf life of 22 days, and can be used to estimate CEA in the range of 2-20 ng ml-1. This paper sensor has been validated by detection of CEA in serum samples of cancer patients via immunoassay technique.

  8. Polyaniline modified flexible conducting paper for cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Saurabh; Sen, Anindita; Kumar, Suveen; Augustine, Shine; Malhotra, Bansi D., E-mail: bansi.malhotra@gmail.com [Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Shahbad Daulatpur, Delhi 110042 (India); Yadav, Birendra K. [Rajiv Gandhi Cancer Institute and Research Centre, Rohini, Delhi 110085 (India); Mishra, Sandeep [Department of Applied Physics, Delhi Technological University, Shahbad Daulatpur, Delhi 110042 (India)

    2016-05-16

    We report results of studies relating to the fabrication of a flexible, disposable, and label free biosensing platform for detection of the cancer biomarker (carcinoembryonic antigen, CEA). Polyaniline (PANI) has been electrochemically deposited over gold sputtered paper (Au@paper) for covalent immobilization of monoclonal carcinoembryonic antibodies (anti-CEA). The bovine serum albumin (BSA) has been used for blocking nonspecific binding sites at the anti-CEA conjugated PANI/Au@Paper. The PANI/Au@Paper, anti-CEA/PANI/Au@Paper, and BSA/anti-CEA/PANI/Au@Paper platforms have been characterized using scanning electron microscopy, X-ray diffraction, Fourier transmission infrared spectroscopy, chronoamperometry, and electrochemical impedance techniques. The results of the electrochemical response studies indicate that this BSA/anti-CEA/PANI/Au@paper electrode has sensitivity of 13.9 μA ng{sup −1} ml cm{sup 2}, shelf life of 22 days, and can be used to estimate CEA in the range of 2–20 ng ml{sup −1}. This paper sensor has been validated by detection of CEA in serum samples of cancer patients via immunoassay technique.

  9. Immunoassays for the measurement of IGF-II, IGFBP-2 and -3, and ICTP as indirect biomarkers of recombinant human growth hormone misuse in sport. Values in selected population of athletes.

    Science.gov (United States)

    Abellan, Rosario; Ventura, Rosa; Palmi, Ilaria; di Carlo, Simonetta; Bacosi, Antonella; Bellver, Montse; Olive, Ramon; Pascual, Jose Antonio; Pacifici, Roberta; Segura, Jordi; Zuccaro, Piergiorgio; Pichini, Simona

    2008-11-04

    Insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBPs) -2 and -3 and C-terminal telopeptide of type I collagen (ICTP) have been proposed, among others, as indirect biomarkers of the recombinant human growth hormone misuse in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays for biomarkers detection was performed. ELISA assays for total IGF-II, IGFBP-2 and IGFBP-3 (IGF-II/ELISA1: DSLabs, IGFBP-2/ELISA2: Biosource, and IGFBP-3/ELISA3: BioSource) and an EIA assay for ICTP (ICTP/EIA: Orion Diagnostica) were evaluated. The inter- and intra-laboratory precision values were acceptable for all evaluated assays (maximum imprecision of 30% and 66% were found only for the lowest quality control samples of IGF-II and IGFBP-3). Correct accuracy was obtained for all inter-laboratory immunoassays and for IGFBP-2 intra-laboratory immunoassay. The range of concentrations found in serum samples under investigation was always covered by the calibration curves of the studied immunoassays. However, 11% and 15% of the samples felt below the estimated LOQ for IGF-II and ICTP, respectively, in the zone where lower precision was obtained. Although the majority of evaluated assays showed an overall reliability not always suitable for antidoping control analysis, relatively high concordances between laboratory results were obtained for all assays. Evaluated immunoassays were used to measure serum concentrations of IGF-II, IGFBP-2 and -3 and ICTP in elite athletes of various sport disciplines at different moments of the training season; in recreational athletes at baseline conditions and finally in sedentary individuals. Serum IGF-II was statistically higher both in recreational and elite athletes compared to sedentary individuals. Elite athletes showed lower IGFBP-2 and higher IGFBP-3 concentration with respect to recreational athletes and sedentary people. Among elite athletes, serum IGFBP-3 (synchronized

  10. A Detection Device for the Signs of Human Life in Accident

    Science.gov (United States)

    Ning, Li; Ruilan, Zhang; Jian, Liu; Ruirui, Cheng; Yuhong, Diao

    2017-12-01

    A detection device for the signs of human life in accidents is a device used in emergency situations, such as the crash site. the scene of natural disasters, the battlefield ruins. it designed to detect the life signs of the distress under the injured ambulance vital signs devices. The device can on human vital signs, including pulse, respiration physiological signals to make rapid and accurate response. After some calculations, and after contrast to normal human physiological parameters given warning signals, in order for them to make timely ambulance judgment. In this case the device is required to do gymnastics convenience, ease of movement, power and detection of small flexible easy realization. This device has the maximum protection of the wounded safety significance.

  11. Consumer-friendly food allergen detection: moving towards smartphone-based immunoassays.

    Science.gov (United States)

    Ross, Georgina M S; Bremer, Monique G E G; Nielen, Michel W F

    2018-03-26

    In this critical review, we provide a comprehensive overview of immunochemical food allergen assays and detectors in the context of their user-friendliness, through their connection to smartphones. Smartphone-based analysis is centered around citizen science, putting analysis into the hands of the consumer. Food allergies represent a significant worldwide health concern and consumers should be able to analyze their foods, whenever and wherever they are, for allergen presence. Owing to the need for a scientific background, traditional laboratory-based detection methods are generally unsuitable for the consumer. Therefore, it is important to develop simple, safe, and rapid assays that can be linked with smartphones as detectors to improve user accessibility. Smartphones make excellent detection systems because of their cameras, embedded flash functions, portability, connectivity, and affordability. Therefore, this review has summarized traditional laboratory-based methods for food allergen detection such as enzyme-linked-immunosorbent assay, flow cytometry, and surface plasmon resonance, and the potential to modernize these methods by interfacing them with a smartphone readout system, based on the aforementioned smartphone characteristics. This is the first review focusing on smartphone-based food-allergen detection methods designed with the intention of being consumer-friendly. Graphical abstract A smartphone-based food allergen detection system in three easy steps (1) sample preparation, (2) allergen detection on a smartphone using antibodies, which then transmits the data wirelessly, (3) analytical results sent straight to smartphone.

  12. Kinase Activity Studied in Living Cells Using an Immunoassay

    Science.gov (United States)

    Bavec, Aljos?a

    2014-01-01

    This laboratory exercise demonstrates the use of an immunoassay for studying kinase enzyme activity in living cells. The advantage over the classical method, in which students have to isolate the enzyme from cell material and measure its activity in vitro, is that enzyme activity is modulated and measured in living cells, providing a more…

  13. Material aging and degradation detection and remaining life assessment for plant life management

    International Nuclear Information System (INIS)

    Ramuhalli, P.; Henager, C.H. Jr.; Griffin, J.W.; Meyer, R.M.; Coble, J.B.; Pitman, S.G.; Bond, L.J.

    2012-01-01

    One of the major factors that may impact long-term operations is structural material degradation. Detecting materials degradation, estimating the remaining useful life (RUL) of the component, and determining approaches to mitigating the degradation are important from the perspective of long-term operations. In this study, multiple nondestructive measurement and monitoring methods were evaluated for their ability to assess the material degradation state. Metrics quantifying the level of damage from these measurements were defined and evaluated for their ability to provide estimates of remaining life of the component. An example of estimating the RUL from nondestructive measurements of material degradation condition is provided. (author)

  14. Carbon nanoparticles as detection labels in antibody microarrays. Detection of genes encoding virulence factors in Shiga toxin-producing Escherichia coli.

    NARCIS (Netherlands)

    Noguera, P.S.; Posthuma-Trumpie, G.A.; Tuil, Van M.; Wal, van der F.J.; Boer, De A.; Moers, A.P.H.A.; Amerongen, Van A.

    2011-01-01

    The present study demonstrates that carbon nanoparticles (CNPs) can be used as labels in microarrays. CNPs were used in nucleic acid microarray immunoassays (NAMIAs) for the detection of different Shiga toxin-producing Escherichia coli (STEC) virulence factors: four genes specific for STEC (vt1,

  15. A multiplex lateral flow immunoassay for the rapid identification of NDM-, KPC-, IMP- and VIM-type and OXA-48-like carbapenemase-producing Enterobacteriaceae

    Science.gov (United States)

    Boutal, Hervé; Vogel, Anaïs; Bernabeu, Sandrine; Devilliers, Karine; Creton, Elodie; Cotellon, Garence; Plaisance, Marc; Oueslati, Saoussen; Dortet, Laurent; Jousset, Agnès; Simon, Stéphanie; Naas, Thierry; Volland, Hervé

    2018-01-01

    Abstract Objectives The global spread of carbapenemase-producing Enterobacteriaceae represents a substantial challenge in clinical practice and rapid and reliable detection of these organisms is essential. The aim of this study was to develop and validate a lateral flow immunoassay (Carba5) for the detection of the five main carbapenemases (KPC-, NDM-, VIM- and IMP-type and OXA-48-like). Methods Carba5 was retrospectively and prospectively evaluated using 296 enterobacterial isolates from agar culture. An isolated colony was suspended in extraction buffer and then loaded on the manufactured Carba5. Results All 185 isolates expressing a carbapenemase related to one of the Carba5 targets were correctly and unambiguously detected in Enterobacteriaceae. PMID:29365094

  16. A new strategy for label-free electrochemical immunoassay based on “gate-effect” of β-cyclodextrin modified electrode

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Huan [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Li, Jianping, E-mail: likianping@263.net [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Zhang, Yun; Pan, Hongcheng [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Xu, Guobao, E-mail: guobaoxu@ciac.ac.cn [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2016-07-05

    A novel label-free electrochemical immunoassay was developed for prostate-specific antigen (PSA) detection via using β-cyclodextrin (β-CD) assembled layer created gates for the electron transfer of probe. To construct the sensor, a gold electrode was self-assembled with monoclonal anti-PSA antibody labeled 6-mercapto-β-cyclodextrin. Interspaces among β-CD molecules in the layer were automatically formed on gold electrode, which act as the channel of the electron transfer of [Fe(CN){sub 6}]{sup 3−/4−} probe. When PSA bind with anti-PSA, it can block these channels on the electrode surface due to their steric hindrance effect, resulting in the decrease in redox current of the probe. Through such a gate-controlled effect, ultra trace amount of PSA may make the currents change greatly after the immunoreaction, which enhanced the signal-to-noise ratio to achieve the amplification effect. By evaluating the logarithm of PSA concentrations, the immunosensor had a good linear response to the current changes with a detection limit of 0.3 pg/mL (S/N = 3) when PSA concentration ranged from 1.0 pg/mL to 1.0 ng/mL. The label-free immunosensor exhibited satisfactory performances in sensitivity, repeatability as well as specificity. - Highlights: • A label-free PSA immunoassay was developed based on “gate-effect” amplification. • Interspaces among β-CD assembled for [Fe(CN){sub 6}]{sup 3−/4−} electron transfer were controlled by the immunoreaction. • Higher sensitivity was achieved with time and cost saving principle.

  17. Optimization of immunochemistry for sensing techniques to detect pesticide residues in water

    DEFF Research Database (Denmark)

    Uthuppu, Basil; Kostesha, Natalie; Jakobsen, Mogens Havsteen

    2011-01-01

    We are working on the development of a real-time electrochemical sensor based on an immunoassay detection system to detect and quantify the presence of pesticide residues in ground water. Highly selective and sensitive immuno-reactions are being investigated to be optimized in order to bring them...

  18. Massively multi-parametric immunoassays using ICPMS

    International Nuclear Information System (INIS)

    Tanner, S.D.; Ornatsky, O.; Bandura, D.R.; Baranov, V.I.

    2009-01-01

    The use of stable isotopes as tags in immunoassays, and their determination by ICPMS, is poised to have a huge impact on multi-parametric bioanalysis. A new technology, which we term 'mass cytometry', enables high throughput, highly multiplexed individual cell analysis. Preliminary results for T-cell immunophenotyping in peripheral blood mononuclear cells (PBMC), agonist influence on concomitant phosphorylation pathways, and sub-classification of acute myeloid leukemia patients' samples will be presented. The significance of individual cell analysis is demonstrated by the identification of populations of rogue cells in PBMC samples through the use of multidimensional neural network cluster analysis. (author)

  19. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences.

    Science.gov (United States)

    Piketty, Marie-Liesse; Polak, Michel; Flechtner, Isabelle; Gonzales-Briceño, Laura; Souberbielle, Jean-Claude

    2017-05-01

    Immunoassays are now commonly used for hormone measurement, in high throughput analytical platforms. Immunoassays are generally robust to interference. However, endogenous analytical error may occur in some patients; this may be encountered in biotin supplementation or in the presence of anti-streptavidin antibody, in immunoassays involving streptavidin-biotin interaction. In these cases, the interference may induce both false positive and false negative results, and simulate a seemingly coherent hormonal profile. It is to be feared that this type of errors will be more frequently observed. This review underlines the importance of keeping close interactions between biologists and clinicians to be able to correlate the hormonal assay results with the clinical picture.

  20. Portable GMR Handheld Platform for the Detection of Influenza A Virus.

    Science.gov (United States)

    Wu, Kai; Klein, Todd; Krishna, Venkatramana D; Su, Diqing; Perez, Andres M; Wang, Jian-Ping

    2017-11-22

    Influenza A virus (IAV) is a common respiratory pathogen infecting many hosts including humans, pigs (swine influenza virus or SIV), and birds (avian influenza virus or AIV). Monitoring swine and avian influenza viruses in the wild, farms, and live poultry markets is of great significance for human and veterinary public health. A portable, sensitive, and quantitative immunoassay device will be of high demand especially in the rural and resource-limited areas. We report herein our Z-Lab point-of-care (POC) device for sensitive and specific detection of swine influenza viruses with minimum sample handling and laboratory skill requirements. In the present study, a portable and quantitative immunoassay platform based on giant magnetoresistive (GMR) technology is used for the detection of IAV nucleoprotein (NP) and purified H3N2v. Z-Lab displays quantitative results in less than 10 min with sensitivities down to 15 ng/mL and 125 TCID 50 /mL for IAV nucleoprotein and purified H3N2v, respectively. This platform allows lab-testing to be performed outdoors and opens up the applications of immunoassays in nonclinical settings.

  1. In vitro conditions modify immunoassayability of bovine pituitary prolactin and growth hormone: insights into their secretory granule storage forms

    International Nuclear Information System (INIS)

    Lorenson, M.Y.

    1985-01-01

    The amount of immunoassayable intracellular bovine (b) PRL and GH varies depending on treatment conditions. The present studies were designed to characterize the mechanisms involved and to compare immunoassayability of both hormones under similar conditions. Pituitary homogenate and secretory granule hormones displayed both time- and temperature-dependent increases when incubated at pH 10.5 with reduced glutathione. Changes in immunoassayability seem to reflect conversion from poorly immunoactive tissue hormone oligomers to monomeric hormone. The data indicate that oligomeric bPRL is stabilized primarily by intermolecular disulfide bonds, although it is also susceptible to urea, SDS, and EDTA; granule thiols may also influence the conversion to monomer. The storage form of bGH appears to be stabilized differently. Maneuvers demonstrated in these studies to influence immunoassayability correlate very well with their previously established effects on hormone release and secretion, strengthening the likelihood that a functional link exists between assayability and secretion

  2. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    Directory of Open Access Journals (Sweden)

    Orazio Ruzzenente

    2016-12-01

    Full Text Available Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB, limit of detection (LOD, functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent (r=1.00 in the range of concentrations between 0.006–75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995 and the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was −3.03 ng/mL (95% confidence interval [CI]: −4.32 to −1.74 ng/mL, whereas the mean bias in samples with PCT concentration between 0–10 ng/mL was −0.49 ng/mL (95% CI: −0.77 to −0.24 ng/mL. The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively. Conclusions: These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market. However, the significant bias compared to the Vidas BRAHMS PCT suggests that the methods cannot be used interchangeably. Keywords: Sepsis, Infection, Procalcitonin, Immunoassay

  3. Polyethylene imine/graphene oxide layer-by-layer surface functionalization for significantly improved limit of detection and binding kinetics of immunoassays on acrylate surfaces.

    Science.gov (United States)

    Miyazaki, Celina M; Mishra, Rohit; Kinahan, David J; Ferreira, Marystela; Ducrée, Jens

    2017-10-01

    Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO) 5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL -1 on commercial grade polystyrene (PS) and 230pgmL -1 on plain PMMA surfaces to 130pgmL -1 on (PEI/GO) 5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Comparison of serum HBsAg quantitation by four immunoassays, and relationships of HBsAg level with HBV replication and HBV genotypes.

    Directory of Open Access Journals (Sweden)

    Edouard Tuaillon

    Full Text Available BACKGROUND: The decline in hepatitis B virus surface antigen (HBsAg may be an early predictor of the viral efficacy of Hepatitis B virus (HBV therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. METHODOLOGY/PRINCIPAL FINDINGS: HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche. Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: -0.06 to 0.11, -0.09 log(10 IU/mL; -0.57 to 0.64, -0.04 log(10 IU/mL; -0.09 to 0.45, -0.27 log(10 IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02, no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15. CONCLUSION/SIGNIFICANCE: The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent.

  5. Functionalization of single-walled carbon nanotubes with protein by click chemistry as sensing platform for sensitized electrochemical immunoassay

    International Nuclear Information System (INIS)

    Qi Honglan; Ling Chen; Huang Ru; Qiu Xiaoying; Shangguan Li; Gao Qiang; Zhang Chengxiao

    2012-01-01

    Highlights: ► Single-walled carbon nanotubes were functionalized with protein by click chemistry. ► The SWNTs conjugated with protein showed excellent dispersion in water and kept good bioacitvity. ► A competitive electrochemical immunoassay for the determination of anti-IgG was developed with high sensitivity and good stability. - Abstract: The application of the Cu(I)-catalyzed [3 + 2] Huisgen cycloaddition to the functionalization of single-walled carbon nanotubes (SWNTs) with the protein and the use of the artificial SWNTs as a sensing platform for sensitive immunoassay were reported. Covalent functionalization of azide decorated SWNTs with alkyne modified protein was firstly accomplished by the Cu(I)-catalyzed [3 + 2] Huisgen cycloaddition. FT-IR spectroscopy, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy and transmission electron micrograph were used to characterize the protein-functionalized SWNTs. It was found that the SWNTs conjugated with the proteins showed excellent dispersion in water and kept good bioacitivity when immunoglobulin (IgG) and horseradish peroxidase (HRP) were chosen as model proteins. As a proof-of-concept, IgG-functionalized SWNTs were immobilized onto the surface of a glassy carbon electrode by simple casting method as immunosensing platform and a sensitive competitive electrochemical immunoassay was developed for the determination of anti-immunoglobulin (anti-IgG) using HRP as enzyme label. The fabrication of the immunosensor were characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the redox probe [Fe(CN) 6 ] 3−/4− . The SWNTs as immobilization platform showed better sensitizing effect, a detection limit of 30 pg mL −1 (S/N = 3) was obtained for anti-IgG. The proposed strategy provided a stable immobilization method and sensitized recognition platform for analytes. This work demonstrated that the click coupling of SWNTs with protein was an effective

  6. Chemiluminescence immunoassay based on dual signal amplification strategy of Au/mesoporous silica and multienzyme functionalized mesoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiehua, E-mail: linjiehua@qust.edu.cn [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhao Yue; Wei Zhijing; Wang Wei [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2011-11-15

    Highlights: > The increased amount of monoclonal antibody in Au/SiO{sub 2} led to a wider linear range. > Due to the increased HRP tags in HRP-Ab{sub 2}/SiO{sub 2}, signal amplification achieved. > A simple dual amplification immunoassay achieved with flow injection analysis. - Abstract: A chemiluminescent dual signal amplification strategy for the determination of {alpha}-fetoprotein (AFP) was proposed based on a sandwich immunoassay format. Monoclonal antibody of AFP immobilized on the gold nanoparticles doped mesoporous SiO{sub 2} (Au/SiO{sub 2}) were prepared and used as a primary antibody. Horseradish peroxidase (HRP) and HRP-labeled secondary antibody (Ab{sub 2}) co-immobilized into the mesoporous SiO{sub 2} nanoparticles (HRP-Ab{sub 2}/SiO{sub 2}) were used as the labeled immunological probe. Due to the high ratio surface areas and pore volumes of the mesoporous SiO{sub 2}, not only the amount of AFP monoclonal antibody but also the amount of the modified HRP and Ab{sub 2} in HRP-Ab{sub 2}/SiO{sub 2} were largely increased. Thus the chemiluminescent signal was amplified by using the system of luminol and H{sub 2}O{sub 2} under the catalysis of HRP. Under the optimal conditions, two linear ranges for AFP were obtained from 0.01 to 0.5 ng mL{sup -1} and 0.5 to 100 ng mL{sup -1} with a detection limit of 0.005 ng mL{sup -1} (3{sigma}). The fabricated signal amplification strategy showed an excellent promise for sensitive detection of AFP and other tumor markers.

  7. Immunoassays for riboflavin and flavin mononucleotide using antibodies specific to d-ribitol and d-ribitol-5-phosphate.

    Science.gov (United States)

    Ravi, G; Venkatesh, Yeldur P

    2017-06-01

    Riboflavin (vitamin B 2 ), a water-soluble vitamin, plays a key role in maintaining human health. Though, numerous methods have been reported for the determination of total riboflavin (TRF) content in foods and biological samples, very few methods are reported for quantifying riboflavin and its coenzymes [flavin mononucleotide (FMN); flavin adenine dinucleotide (FAD)] individually. Recently, we have demonstrated that antibodies specific to d-ribitol and d-ribitol-5-phosphate also recognize riboflavin and FMN, respectively, and not vice-versa. In this study, we have evaluated these two antibodies for the analysis of riboflavin and FMN by indirect competitive ELISA (icELISA) in selected foods and pharmaceuticals. Under the optimal assay conditions, 50% inhibition concentration (IC 50 ) and limit of detection (LOD, IC 10 ) were 3.41ng/mL and 0.02ng/mL for riboflavin, and 7.84ng/mL and 0.24ng/mL for FMN, respectively, with detectable concentration range between 0.1 and 100ng of analytes and riboflavin and FMN) from the same food samples showed variation in their values compared to TRF, and were in good agreement with values obtained from HPLC and AOAC methods. Further, spiking and recovery analysis of food samples and pharmaceuticals showed no significant matrix effects. The immunoassays were validated in terms of accuracy and precision using inter- and intra-assays. The immunoassays developed in this study are sensitive and appears feasible for screening a large number of samples in the quantification of riboflavin and FMN in various biological samples, pharmaceuticals and natural/processed foods. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT Based on Time-Resolved Immunochromatography

    Directory of Open Access Journals (Sweden)

    Xiang-Yang Shao

    2017-02-01

    Full Text Available Procalcitonin (PCT is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA combined with lateral flow immunoassay (LFIA. The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL. The inter-assay coefficient of variation (CV and the intra-assay CV were 5.4%–7.7% and 5.7%–13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation (n = 234, r = 0.977, p < 0.0001 and consistency (Kappa = 0.875 were obtained when compared with the PCT kit from Roche Elecsys BRAHMS. Thus, the new quantitative method for detecting PCT has been successfully established. The results indicated that the newly-developed system based on TRFIA combined with LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.

  9. An Ultrasensitive Electrochemiluminescence Immunoassay for Carbohydrate Antigen 19-9 in Serum Based on Antibody Labeled Fe3O4 Nanoparticles as Capture Probes and Graphene/CdTe Quantum Dot Bionanoconjugates as Signal Amplifiers

    Science.gov (United States)

    Gan, Ning; Zhou, Jing; Xiong, Ping; Li, Tianhua; Jiang, Shan; Cao, Yuting; Jiang, Qianli

    2013-01-01

    The CdTe quantum dots (QDs), graphene nanocomposite (CdTe-G) and dextran–Fe3O4 magnetic nanoparticles have been synthesized for developing an ultrasensitive electrochemiluminescence (ECL) immunoassay for Carcinoembryonic antigen 19-9 (CA 19-9) in serums. Firstly, the capture probes (CA 19-9 Ab1/Fe3O4) for enriching CA 19-9 were synthesized by immobilizing the CA 19-9’s first antibody (CA 19-9 Ab1) on magnetic nanoparticles (dextran-Fe3O4). Secondly, the signal probes (CA 19-9 Ab2/CdTe-G), which can emit an ECL signal, were formed by attaching the secondary CA 19-9 antibody (CA 19-9 Ab2) to the surface of the CdTe-G. Thirdly, the above two probes were used for conjugating with a serial of CA 19-9 concentrations. Graphene can immobilize dozens of CdTe QDs on their surface, which can emit stronger ECL intensity than CdTe QDs. Based on the amplified signal, ultrasensitive antigen detection can be realized. Under the optimal conditions, the ECL signal depended linearly on the logarithm of CA 19-9 concentration from 0.005 to 100 pg/mL, and the detection limit was 0.002 pg/mL. Finally, five samples of human serum were tested, and the results were compared with a time-resolved fluorescence assay (TRFA). The novel immunoassay provides a stable, specific and highly sensitive immunoassay protocol for tumor marker detection at very low levels, which can be applied in early diagnosis of tumor. PMID:23685872

  10. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  11. Dog cloning with in vivo matured oocytes obtained using electric chemiluminescence immunoassay-predicted ovulation method.

    Science.gov (United States)

    Lee, Seunghoon; Zhao, Minghui; No, Jingu; Nam, Yoonseok; Im, Gi-Sun; Hur, Tai-Young

    2017-01-01

    Radioactive immunoassay (RIA) is a traditional serum hormone assay method, but the application of the method in reproductive studies is limited by the associated radioactivity. The aim of present study was to evaluate the reliability of RIA and to compare its canine serum progesterone concentration determination accuracy to that of the electric chemiluminescence immunoassay (ECLI). In vivo matured oocytes were utilized for canine somatic cell nuclear transfer (SCNT), and serum progesterone levels were assessed to accurately determine ovulation and oocyte maturation. Canine serum progesterone concentrations during both proestrus and estrus were analyzed by RIA and ECLI to determine the ovulation day. Although both methods detected similar progesterone levels before ovulation, the mean progesterone concentration determined using ECLI was significantly higher than of RIA three days before ovulation. Following ovulation, oocytes were collected by surgery, and a lower percentage of mature oocytes were observed using ECLI (39%) as compared to RIA (67%) if 4-8ng/ml of progesterone were used for determination of ovulation. A high percentage of mature oocytes was observed using ECLI when 6-15 ng/mL of progesterone was used for ovulation determination. To determine whether ECLI could be used for canine cloning, six canines were selected as oocyte donors, and two puppies were obtained after SCNT and embryo transfer. In conclusion, compared to the traditional RIA method, the ECLI method is a safe and reliable method for canine cloning.

  12. Enzyme immunoassay for DDT analysis in Lebanese soils

    International Nuclear Information System (INIS)

    Bashour, I.; Dagher, S.; Shammas, G.; Sukkariyah, B.; Kawar, N.

    2000-01-01

    Full text: The use of enzyme-linked immunosorbent assay (ELISA) technique in estimating pesticide residue in soils is a faster, less expensive and easier method to use than the gas chromatography (GC) analysis technique..In the test, DDT pesticide residues in the simple compete with enzyme (horseradish peroxidase)-labeled DDT for a limited number of antibody binding sites on the inside surfaces of the test wells; the envirologix plate kit was tested for the measurement of total DDT in virgin and fortified (0-1000 ng g exp-1) soil samples of different properties from Lebanon. Extraction of DDT from soil was done by shaking the samples for 16 hours on a mechanical shaker with 90% methanol without any clean-up steps. Then the samples were allowed to stand for 30 minutes and an aliquot was taken from the clear supernatant. The DDT in the extract was measured in triplicate by GC and ELISA. The results indicated that the two techniques were highly correlated (r2 =0.9671-0.9973). Differences in soils physical and chemical properties did not accuracy of the detection limits of ELISA when compared to GC-ECD results. Immunoassay technique is a suitable method for rapid and accurate measurement of DDT residue in mineral Lebanese soils

  13. Implementation of a rapid HIT immunoassay at a university hospital - Retrospective analysis of HIT laboratory orders in patients with thrombocytopenia.

    Science.gov (United States)

    Black, Anne; Heimerl, Susanne; Oertli, Linnéa; Wilczek, Wolf; Greinacher, Andreas; Spannagl, Michael; Herr, Wolfgang; Hart, Christina

    2017-10-01

    Heparin-induced thrombocytopenia (HIT) is a rare cause of thrombocytopenia and a potentially life-threatening adverse drug reaction. Clinical overdiagnosis of HIT results in costly laboratory tests and anticoagulation. Criteria and algorithms for diagnosis are established, but their translation into clinical practice is still challenging. In a retrospective approach we studied all HIT related laboratory test requests within four years and evaluated data before (1st period, 24month) and after (2nd period, 24month) replacing particle gel immunoassay (PaGIA) and enzyme-linked immunosorbent assay (ELISA) by a chemiluminescent immunoassay (CLIA). HIT was confirmed by heparin-induced platelet activation (HIPA) test. Clinical pretest probability for HIT using an implemented simplified 4Ts score and platelet count were evaluated. Costs for laboratory tests and alternative anticoagulation were calculated. In 1850 patients with suspected HIT, 2327 laboratory orders were performed. In 87.2% of these orders an intermediate/high simplified 4Ts score was found. Thrombocytopenia was present in 87.1%. After replacing PaGIA and ELISA by CLIA the number of immunological and functional laboratory tests was reduced by 38.2%. The number of positive HIT immunoassays declined from 22.6% to 6.0%, while the number of positive HIPA tests among positive immunological tests increased by 19%. Altogether, acute HIT was confirmed in 59 patients. A decline in the use of alternative anticoagulants was observed in the 2nd period. Our study shows that in a university hospital setting HIT is well-known, but diagnosis requires a precise laboratory confirmation. Replacing PaGIA and ELISA by CLIA did not influence laboratory order behavior but results in reduced overall costs for laboratory diagnostics and alternative anticoagulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler.

    Science.gov (United States)

    Miyajima, Kumiko; Suzuki, Yurika; Miki, Daisuke; Arai, Moeka; Arakawa, Takahiro; Shimomura, Hiroji; Shiba, Kiyoko; Mitsubayashi, Kohji

    2014-06-01

    Dermatophagoides farinae allergen (Der f1) is one of the most important indoor allergens associated with allergic diseases in humans. Mite allergen Der f1 is usually associated with particles of high molecular weight; thus, Der f1 is generally present in settled dust. However, a small quantity of Der f1 can be aerosolized and become an airborne component. Until now, a reliable method of detecting airborne Der f1 has not been developed. The aim of this study was to develop a fiber-optic chemifluorescent immunoassay for the detection of airborne Der f1. In this method, the Der f1 concentration measured on the basis of the intensity of fluorescence amplified by an enzymatic reaction between the labeled enzyme by a detection antibody and a fluorescent substrate. The measured Der f1 concentration was in the range from 0.49 to 250 ng/ml and a similar range was found by enzyme-linked immunosorbent assay (ELISA). This method was proved to be highly sensitive to Der f1 compared with other airborne allergens. For the implementation of airborne allergen measurement in a residential environment, a bioaerosol sampler was constructed. The airborne allergen generated by a nebulizer was conveyed to a newly sampler we developed for collecting airborne Der f1. The sampler was composed of polymethyl methacrylate (PMMA) cells for gas/liquid phases and some porous membranes which were sandwiched in between the two phases. Der f1 in air was collected by the sampler and measured using the fiber-optic immunoassay system. The concentration of Der f1 in aerosolized standards was in the range from 0.125 to 2.0 mg/m(3) and the collection rate of the device was approximately 0.2%. © 2013 Elsevier B.V. All rights reserved.

  15. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: Implications for immunoassays

    DEFF Research Database (Denmark)

    Jørgensen, Kaj Anker; Karamperis, Nikolaos; Koefoed-Nielsen, Pernille Bundgaard

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  16. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: implications for immunoassays

    DEFF Research Database (Denmark)

    Karamperis, N; Koefoed-Nielsen, PB; Brahe, P

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  17. Help in the Choice of Automated or Semiautomated Immunoassays for Serological Diagnosis of Toxoplasmosis: Evaluation of Nine Immunoassays by the French National Reference Center for Toxoplasmosis.

    Science.gov (United States)

    Villard, O; Cimon, B; L'Ollivier, C; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E

    2016-12-01

    Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgM Toxoplasma gondii antibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. IMMUNOASSAY METHOD FOR THE DETERMINATION OF PENTACHLOROPHENOL IN SOIL AND SEDIMENT

    Science.gov (United States)

    The journal article describes the use of a prototype immunoassay method for the determination of pentacholorphenol (PCP) in soil and sediment. PCP was used as a pesticide and wood preservative and is not currently available to the general public. The paper stresses the importan...

  19. Correlation of antinuclear antibody immunofluorescence patterns with immune profile using line immunoassay in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Sebastian Wendy

    2010-07-01

    were projectable to visualize a certain spectrum of specific antibodies such as homogenous (45.5% with dsDNA, nucleosomes, histones, SSA / Ro-52, RIB and RNP / Sm, speckled pattern (35.6% with Sm, RNP, SSA/Ro-52, SSB, Sm and RIB; nucleolar pattern with Scl-70, Sm, RNP and centromere pattern with CENP-B. The methodology indicated that, cytoplasmic pattern noted in ANA also needs to be correlated with primate liver in a biochip, which should prompt further decision for a request for line immunoassay and it is preferable for two pathologists to report independently and sign out a consensus ANA report for better predictive value. Conclusions: As a definite correlation between the ANA patterns and the group of antibodies was detected by line immunoassay, one could predict presence of certain specific auto antibodies for a particular ANA pattern identified. This may restrict one from requesting for line immunoassay, which is expensive and economizes on the cost of laboratory investigations in a developing country like India. Thus, screening of sera by ANA-IIF method alone may suffice and probably reduce the expense of detailed immunological work-up with minimal loss in diagnostic accuracy. This study, the first of its kind in India, provides database and reference for the Indian subpopulation.

  20. The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays.

    Science.gov (United States)

    Zhan, Li; Guo, Shuang-Zhuang; Song, Fayi; Gong, Yan; Xu, Feng; Boulware, David R; McAlpine, Michael C; Chan, Warren C W; Bischof, John C

    2017-12-13

    Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.

  1. Immunoassay detection of drugs in racing horses. IX. Detection of detomidine in equine blood and urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Wood, T.; Tai, C.L.; Taylor, D.G.

    1989-01-01

    Detomidine is a potent non-narcotic sedative agent which is currently in the process of being approved for veterinary clinical use in the United States. Since no effective screening method in horses is available for detomidine, we have developed an 125 I radioimmunoassay for detomidine in equine blood and urine as part of a panel of tests for illegal drugs in performance horses. Our 125 I radioimmunoassay has an I-50 for detomidine of approximately 2 ng/ml. Our assay shows limited cross-reactivity with the pharmacodynamically similar xylazine, but does not cross-react with acepromazine, epinephrine, haloperidol or promazine. The plasma kinetic data from clinical (greater than or equal to 5 mg/horse) as well as sub-clinical doses indicate first-order elimination in a dose-dependent manner. Within the first 30 minutes after intravenous (IV) administration of 30 mg/horse, plasma levels peak at approximately 20 ng/ml and then decline with an apparent plasma half-life of 25 minutes. Diuresis can occur with administration of clinical doses of detomidine and this effect was accounted for in the analysis of urine samples. Using this method, administration of 30 mg/horse can be readily detected in equine urine for up to 8 hours after IV injection. Additionally, doses as low as 0.5 mg/horse can be detected for short periods of time in blood and urine with use of this assay. Utilization of this assay by research scientists and forensic analysts will allow for the establishment of proper guidelines and controls regarding detomidine administration to performance horses and assurance of compliance with these guidelines

  2. Microsphere-based immunoassay integrated with a microfluidic network to perform logic operations

    International Nuclear Information System (INIS)

    Sabhachandani, Pooja; Cohen, Noa; Sarkar, Saheli; Konry, Tania

    2015-01-01

    Lab on a chip (LOC) intelligent diagnostics can be described by molecular logic-based circuits. We report on the development of an LOC approach with logic capability for screening combinations of antigen and antibody in the same sample. A microsphere-based immunoassay was integrated with a microfluidic network device to perform the logic operations AND and INHIBIT. Using the clinically relevant biomarkers TNF-α cytokine and anti-TNF-α antibody, we obtained a fluorescent output in the presence of both inputs. This results in an AND operation, while the presence of only one specific input results in a different fluorescent signal, thereby indicating the INHIBIT operation. This approach demonstrates the effective use of molecular logic computation for developing portable, point-of-care technologies for diagnostic purposes due to fast detection times, minimal reagent consumption and low costs. This model system may be further expanded to screening of multiple disease markers, combinatorial logic applications, and developing “smart” sensors and therapeutic technologies. (author)

  3. Enzyme immunoassays for the diagnosis of bovine brucellosis. Trial in Latin America

    International Nuclear Information System (INIS)

    Gall, D.; Nielsen, K.; Colling, A.; Marino, O.; Moreno, E.; Perez, B.; Samartino, L.

    1998-01-01

    The results of a field trail conducted in Latin America with two indirect (IELISA) and two competitive (CELISA) enzyme immunoassays for the detection of bovine antibody to Brucella abortus are reported. One of the CELISA formats performed most accurately. The relative sensitivity of this assay was 97.47%, the relative specificity for unexposed cattle was 98.32% and the specificity in cattle vaccinated with B. abortus strain 19 was 96.51%. The same assay format under Canadian conditions had a sensitivity of 100%, a specificity of 99.90% and a specificity of 97.7% in a strain 19 vaccinated population. Overall, the CELISA performed as expected and the results were not dissimilar to the results obtained in the Canadian study thus providing further evidence that this CELISA can in many instances differentiate infected cattle from those that are vaccinated or infected with a cross-reacting organism while still giving very low false positive or false negative results. (author)

  4. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation.

    Science.gov (United States)

    Dittmer, W U; de Kievit, P; Prins, M W J; Vissers, J L M; Mersch, M E C; Martens, M F W C

    2008-09-30

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions as well as the bound/free separation are entirely controlled by magnetic forces induced by electromagnets above and below the sensor chip. During the assay, particles conjugated with tracer antibodies are actuated through the sample for target capture, and rapidly brought to the sensor surface where they bind to immobilized capture antibodies. Weakly or unbound labels are removed with a magnetic force oriented away from the GMR sensor surface. For the measurement of parathyroid hormone (PTH), a detection limit in the 10 pM range is obtained with a total assay time of 15 min when 300 nm particles are used. The same sensitivity can be achieved in 5 min when 500 nm particles are used. If 500 nm particles are employed in a 15-minute assay, then 0.8 pM of PTH is detectable. The low sample volume, high analytical performance and high speed of the test coupled with the compact GMR biosensor make the system especially suitable for sensitive testing outside of laboratory environments.

  5. Immunoassay for thymopoietin

    International Nuclear Information System (INIS)

    Goldstein, G.

    1979-01-01

    The patent describes the development of a radio-immunoassay for thymopoietin in biological samples. The method of raising antibodies to this polypeptide hormone is described. This is achieved by injecting a host animal with an antigen consisting of thymopoietin covalently bonded by glutaraldehyde to a carrier protein such as bovine serum albumin and equine globulin. Different methods of radiolabelling thymopoietin with 125 I for use as the tracer antigen are described. The Bolton-Hunter procedure was preferred to the chloramine-T method since direct iodination of the tyrosyl moieties of thymopoietin resulted in some loss of immunoreactivity. Systems for separating the antigen-antibody complex and unbound antigen are compared. Binding-inhibition curves for unlabelled thymopoietin in the assay employing polyethylene glycol separation showed a sensitivity of 5 ng thymopoietin/ml. However, using the double antibody or dextran coated charcoal separation techniques, the sensitivity of thymopoietin was 0.1 ng/ml. Thus these latter two procedures are thus especially suitable for measuring thymopoietin levels in serum or plasma samples. The assay was shown to be specific for thymopoietin, no significant displacement being produced by control polypeptides. (U.K.)

  6. Biota and biomolecules in extreme environments on Earth: implications for life detection on Mars.

    Science.gov (United States)

    Aerts, Joost W; Röling, Wilfred F M; Elsaesser, Andreas; Ehrenfreund, Pascale

    2014-10-13

    The three main requirements for life as we know it are the presence of organic compounds, liquid water, and free energy. Several groups of organic compounds (e.g., amino acids, nucleobases, lipids) occur in all life forms on Earth and are used as diagnostic molecules, i.e., biomarkers, for the characterization of extant or extinct life. Due to their indispensability for life on Earth, these biomarkers are also prime targets in the search for life on Mars. Biomarkers degrade over time; in situ environmental conditions influence the preservation of those molecules. Nonetheless, upon shielding (e.g., by mineral surfaces), particular biomarkers can persist for billions of years, making them of vital importance in answering questions about the origins and limits of life on early Earth and Mars. The search for organic material and biosignatures on Mars is particularly challenging due to the hostile environment and its effect on organic compounds near the surface. In support of life detection on Mars, it is crucial to investigate analogue environments on Earth that resemble best past and present Mars conditions. Terrestrial extreme environments offer a rich source of information allowing us to determine how extreme conditions affect life and molecules associated with it. Extremophilic organisms have adapted to the most stunning conditions on Earth in environments with often unique geological and chemical features. One challenge in detecting biomarkers is to optimize extraction, since organic molecules can be low in abundance and can strongly adsorb to mineral surfaces. Methods and analytical tools in the field of life science are continuously improving. Amplification methods are very useful for the detection of low concentrations of genomic material but most other organic molecules are not prone to amplification methods. Therefore, a great deal depends on the extraction efficiency. The questions "what to look for", "where to look", and "how to look for it" require more of

  7. Biota and Biomolecules in Extreme Environments on Earth: Implications for Life Detection on Mars

    Directory of Open Access Journals (Sweden)

    Joost W. Aerts

    2014-10-01

    Full Text Available The three main requirements for life as we know it are the presence of organic compounds, liquid water, and free energy. Several groups of organic compounds (e.g., amino acids, nucleobases, lipids occur in all life forms on Earth and are used as diagnostic molecules, i.e., biomarkers, for the characterization of extant or extinct life. Due to their indispensability for life on Earth, these biomarkers are also prime targets in the search for life on Mars. Biomarkers degrade over time; in situ environmental conditions influence the preservation of those molecules. Nonetheless, upon shielding (e.g., by mineral surfaces, particular biomarkers can persist for billions of years, making them of vital importance in answering questions about the origins and limits of life on early Earth and Mars. The search for organic material and biosignatures on Mars is particularly challenging due to the hostile environment and its effect on organic compounds near the surface. In support of life detection on Mars, it is crucial to investigate analogue environments on Earth that resemble best past and present Mars conditions. Terrestrial extreme environments offer a rich source of information allowing us to determine how extreme conditions affect life and molecules associated with it. Extremophilic organisms have adapted to the most stunning conditions on Earth in environments with often unique geological and chemical features. One challenge in detecting biomarkers is to optimize extraction, since organic molecules can be low in abundance and can strongly adsorb to mineral surfaces. Methods and analytical tools in the field of life science are continuously improving. Amplification methods are very useful for the detection of low concentrations of genomic material but most other organic molecules are not prone to amplification methods. Therefore, a great deal depends on the extraction efficiency. The questions “what to look for”, “where to look”, and “how to

  8. Detecting the Immune System Response of a 500 Year-Old Inca Mummy

    Science.gov (United States)

    Corthals, Angelique; Koller, Antonius; Martin, Dwight W.; Rieger, Robert; Chen, Emily I.; Bernaski, Mario; Recagno, Gabriella; Dávalos, Liliana M.

    2012-01-01

    Disease detection in historical samples currently relies on DNA extraction and amplification, or immunoassays. These techniques only establish pathogen presence rather than active disease. We report the first use of shotgun proteomics to detect the protein expression profile of buccal swabs and cloth samples from two 500-year-old Andean mummies. The profile of one of the mummies is consistent with immune system response to severe pulmonary bacterial infection at the time of death. Presence of a probably pathogenic Mycobacterium sp. in one buccal swab was confirmed by DNA amplification, sequencing, and phylogenetic analyses. Our study provides positive evidence of active pathogenic infection in an ancient sample for the first time. The protocol introduced here is less susceptible to contamination than DNA-based or immunoassay-based studies. In scarce forensic samples, shotgun proteomics narrows the range of pathogens to detect using DNA assays, reducing cost. This analytical technique can be broadly applied for detecting infection in ancient samples to answer questions on the historical ecology of specific pathogens, as well as in medico-legal cases when active pathogenic infection is suspected. PMID:22848450

  9. Time-Resolved Analysis of a Highly Sensitive Förster Resonance Energy Transfer Immunoassay Using Terbium Complexes as Donors and Quantum Dots as Acceptors

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2007-01-01

    Full Text Available CdSe/ZnS core/shell quantum dots (QDs are used as efficient Förster Resonance Energy Transfer (FRET acceptors in a time-resolved immunoassays with Tb complexes as donors providing a long-lived luminescence decay. A detailed decay time analysis of the FRET process is presented. QD FRET sensitization is evidenced by a more than 1000-fold increase of the QD luminescence decay time reaching ca. 0.5 milliseconds, the same value to which the Tb donor decay time is quenched due to FRET to the QD acceptors. The FRET system has an extremely large Förster radius of approx. 100 Å and more than 70% FRET efficiency with a mean donor-acceptor distance of ca. 84 Å, confirming the applied biotin-streptavidin binding system. Time-resolved measurement allows for suppression of short-lived emission due to background fluorescence and directly excited QDs. By this means a detection limit of 18 attomol QDs within the immunoassay is accomplished, an improvement of more than two orders of magnitude compared to commercial systems.

  10. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2011-11-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  11. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Liang, Cai; Useinov, Arthur; Kosel, Jü rgen; Giouroudi, Ioanna

    2011-01-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  12. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    Science.gov (United States)

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled

  13. Comparison of clinical performance of antigen basedenzyme immunoassay (EIA and major outer membrane protein (MOMP-PCR for detection of genital Chlamydia trachomatis infection

    Directory of Open Access Journals (Sweden)

    Mahmoud Nateghi Rostami

    2016-06-01

    Full Text Available Background: Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Objective: Performances of enzyme immunoassay (EIA and major outer membrane protein (MOMP-polymerase chain reaction (PCR for diagnosis of genital C.trachomatis infection in women were compared. Materials and Methods: In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV and negative predictive values (NPV were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. Results: In total, 37 (7.14% cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMPPCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48. Conclusion: C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  14. Development of monoclonal antibody-based immunoassays for the analysis of bisphenol A in canned vegetables.

    Science.gov (United States)

    Moreno, María J; D'Arienzo, Pasquale; Manclús, Juan J; Montoya, Angel

    2011-01-01

    The aim of this work was the development of monoclonal antibodies (MAbs) and highly sensitive immunoassays (ELISAs) to bisphenol A (BPA), a well-known endocrine disruptor able to migrate from the internal coating of cans to food contained inside, particularly vegetables. To produce MAbs to BPA, four synthetic compounds were conjugated to proteins and used as immunizing haptens in mice. By applying hybridoma technology, several MAbs were produced and selected. These antibodies were characterized in the conjugate-coated and in the antibody-coated formats, using both homologous and heterologous conjugates. Three indirect ELISA based on the MAbs showing the highest affinity to BPA were selected. The limit of detection of the most sensitive ELISA was 0.22 nM (0.05 ng/mL), with an I₅₀ value of around 1 nM (0.23 ng/mL). An homologous ELISA based on the MAb BPAB-11 was applied to the simple, direct determination of BPA in the liquid portion of canned artichoke, peas, and sweet corn. Only sample dilution in an appropriate saline buffer was required to minimize matrix effects and to enter the ELISA working range. Recovery and precision of the method were evaluated by spiking the liquid portion of these cans with BPA at 20, 50, and 100 ng/mL. Coefficients of variation were below 20% in most cases. With regard to recovery, the analytical data obtained were also acceptable. This immunoassay has therefore proved its potential as a new tool for the rapid, sensitive and accurate determination of BPA in canned food.

  15. Oligopeptide-based enzyme immunoassay for ovine lentivirus antibody detection.

    OpenAIRE

    Kwang, J; Torres, J V

    1994-01-01

    Ovine progressive pneumonia virus (OPPV) is a lentivirus which causes a progressive disease in sheep. Immunodominant epitopes have been identified in the envelope gp40 glycoprotein. Synthetic peptides representing these regions are able to detect the presence of OPPV antibodies in 96% of infected sheep.

  16. Development of an enzyme immunoassay for the antibiotic cefquinome and its application for residue determination in cow's milk after therapeutical mastitis treatment.

    Science.gov (United States)

    Thal, Johannes; Steffen, Monika; Meier, Bianca; Schneider, Elisabeth; Adriany, Ansgar; Usleber, Ewald

    2011-01-01

    The aim of this study was to develop and evaluate an enzyme immunoassay (EIA) for the cephalosporin antibiotic in milk, in combination with a new microbiological test system (brilliant black reduction test, BRT-P). Polyclonal antibodies against cefquinome were produced in rabbits, using cefquinome-keyhole limpet hemocyanine as the immunogen. These antibodies and a cefquinome-glucose oxidase conjugate were used in a competitive indirect EIA. The detection limit for cefquinome in milk was 1.5 ng ml(-1), recoveries were 80-128% at 4-40 ng ml(-1). Cross-reactivities with other cephalosporins/penicillins were all <1%. The EIA was used to determine cefquinome in incurred raw milk, the BRT-P (detection limit ≈ 20 ng ml(-1)) and a receptor assay (ßeta-s.t.a.r., detection limit ≈ 15 ng ml(-1)) were used in parallel. Five lactating cows, suffering from clinical mastitis, were treated with cefquinome by simultaneous intramammary and intramuscular injection. Cefquinome residues (maximum 10-27 μg ml(-1)) were most exclusively found in the udder quarter which was treated intramammary, residue levels in the other three quarters were low (<20 ng ml(-1)). Even in milk from intramammary-dosed quarters, residue levels fell below European Union maximum residue level (MRL, 20 μg kg(-1)) 2 days before the end of the withdrawal period. EIA, BRT-P, and ßeta-s.t.a.r. results showed acceptable agreement for milk samples, but the newly developed EIA is superior in aspects of sensitivity. In conclusion, this is the first one description of immunoassay and microbiological tests capable to determine cefquinome in milk at the MRL in incurred sample material.

  17. Immunoassay: Principles, development and potential applications in the applied plant sciences

    Energy Technology Data Exchange (ETDEWEB)

    Hofman, P J

    1986-02-01

    The article briefly discusses the general principles of, and the methods involved in, immunoassay, and their development. Emplasis is placed on radioimmunoassay (RIA) and to a lesser extent, enzyme-linked immunosorbent assay (ELISA). The practical applications, with special reference to the citrus and subtropical fruit industries are discussed.

  18. Design of novel hybrid organic-inorganic nanostructured biomaterials for immunoassay applications

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, G [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Barbosa-Stancioli, E F [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Piscitelli Mansur, A A [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Vasconcelos, W L [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Mansur, H S [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil)

    2006-12-01

    The purpose of this study was to develop novel hybrid organic-inorganic materials based on poly(vinyl alcohol) (PVA) polymer chemically crosslinked network to be tested as solid support on bovine herpesvirus immunoassay. Hybrids were synthesized by reacting PVA with three different alkoxysilanes modifying chemical groups: tetraethoxysilane (TEOS), 3-mercaptopropyltrimethoxysilane (MPTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS). PVA-derived hybrids were also modified by chemically crosslinking with glutaraldehyde (GA) during the synthesis reaction. In order to investigate the structure in the nanometer-scale, PVA-derived hybrids were characterized by using small-angle x-ray scattering synchrotron radiation (SAXS) and x-ray diffraction (XRD). PVA hybrids' chemical functionalities and their interaction with herpesviruses were also characterized by Fourier transform infrared spectroscopy (FTIR). The bioactivity assays were tested through enzyme linked immunosorbent assay (ELISA). SAXS results have indicated nano-ordered disperse domains for PVA hybrids with different x-ray scattering patterns for PVA polymer and PVA-derived hybrids. FTIR spectra have shown major vibration bands associated with organic-inorganic chemical groups present in the PVA, PVA-derived by silane modifier and PVA chemically crosslinked by GA. The immunoassay results have shown that PVA hybrids with chemically functionalized structures regulated to some extent the specific bioimmobilization of herpesvirus onto solid phase. We think that it is due to the overall balance of forces associated with van der Waals interaction, hydrophilic and hydrophobic forces and steric hindrance acting at the surface. PVA and PVA-derived hybrid materials were successfully produced with GA crosslinking in a nanometer-scale network. Also, such a PVA-based material could be advantageously used in immunoassays with enhanced specificity for diagnosis.

  19. Design of novel hybrid organic-inorganic nanostructured biomaterials for immunoassay applications

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, G [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Barbosa-Stancioli, E F [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Piscitelli Mansur, A A [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Vasconcelos, W L [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Mansur, H S [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil)

    2006-12-01

    The purpose of this study was to develop novel hybrid organic-inorganic materials based on poly(vinyl alcohol) (PVA) polymer chemically crosslinked network to be tested as solid support on bovine herpesvirus immunoassay. Hybrids were synthesized by reacting PVA with three different alkoxysilanes modifying chemical groups: tetraethoxysilane (TEOS), 3-mercaptopropyltrimethoxysilane (MPTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS). PVA-derived hybrids were also modified by chemically crosslinking with glutaraldehyde (GA) during the synthesis reaction. In order to investigate the structure in the nanometer-scale, PVA-derived hybrids were characterized by using small-angle x-ray scattering synchrotron radiation (SAXS) and x-ray diffraction (XRD). PVA hybrids' chemical functionalities and their interaction with herpesviruses were also characterized by Fourier transform infrared spectroscopy (FTIR). The bioactivity assays were tested through enzyme linked immunosorbent assay (ELISA). SAXS results have indicated nano-ordered disperse domains for PVA hybrids with different x-ray scattering patterns for PVA polymer and PVA-derived hybrids. FTIR spectra have shown major vibration bands associated with organic-inorganic chemical groups present in the PVA, PVA-derived by silane modifier and PVA chemically crosslinked by GA. The immunoassay results have shown that PVA hybrids with chemically functionalized structures regulated to some extent the specific bioimmobilization of herpesvirus onto solid phase. We think that it is due to the overall balance of forces associated with van der Waals interaction, hydrophilic and hydrophobic forces and steric hindrance acting at the surface. PVA and PVA-derived hybrid materials were successfully produced with GA crosslinking in a nanometer-scale network. Also, such a PVA-based material could be advantageously used in immunoassays with enhanced specificity for diagnosis.

  20. Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen

    Directory of Open Access Journals (Sweden)

    Claudia Lamarca Vitral

    1991-06-01

    Full Text Available Two competitive enzyme immunoassays (EIA techniques were developed: in the first (COMP-1, test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2, test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.Foram desenvolvidos dois ensaios imunoenzimáticos (EIA competitivos: no primeiro (COMP-1 colocou-se numa placa sensibilizada com anti-HAVIgG as amostras teste juntamente como antígeno HA Vea seguir o conjugado anti-HA VHRP; no segundo (COMP-2, as amostras teste e o conjugado anti-HAV HRP competem pelos epitopos do antígeno HAV previamente absorvido na placa sensibilizada do anti-HAV IgG. O substrato utilizado foi tetrametilbenzidina (TMB. Ambas as técnicas mostraram ser produtíveis e aplicáveis para fins de diagnóstico e pesquisa.

  1. [Use of monoclonal antibodies against horse immunoglobulin in an enzyme immunoassay of bacterial toxins and anatoxins].

    Science.gov (United States)

    Burkin, M A; Gal'vidis, I A; Iakovleva, I V; Sviridov, V V

    2007-01-01

    Immunization of BALB/c mice by horse antiserum against diphtheria made it possible to obtain IgG1 monoclonal antibodies (MoAbs) 2B7E4 specific for light chains of horse immunoglobulin (Ig). Unlike commercial preparations of anti-horse immunoglobulin antibodies, which are specific for the whole Ig molecule or its Fc-fragment, the peroxidase (HRP) conjugate of the MoAb, 2B7E4-HRP did not interact with human, mouse, rabbit, and sheep Igs, or horse albumin. The conjugate obtained was used with MoAbs against bacterial toxins and commercial horse anatoxins, as a universal reagent in sandwich enzyme immunoassay (ELISA) for bacterial toxins and anatoxins. The detection sensitivity of diphtheria toxin/anatoxin equaled 0.0005 Lf/ml; tetanus toxin and anatoxin were detected with sensitivities of 20 LD50/ml and 0.005 UI/ml, respectively. A similar sandwich ELISA for botulinum anatoxins (group measurement) allowed types A, B, and E to be detected at 0.02, 0.002, and 0.001 UI/ml, respectively; selective measurement was only possible in the case of type E anatoxin (0.001 UI/ml).

  2. Chemiluminescence Immunoassay for the Detection of Antibodies against the 2C and 3ABC Nonstructural Proteins Induced by Infecting Pigs with Foot-and-Mouth Disease Virus.

    Science.gov (United States)

    Liu, Zezhong; Shao, Junjun; Zhao, Furong; Zhou, Guangqing; Gao, Shandian; Liu, Wei; Lv, Jianliang; Li, Xiumei; Li, Yangfan; Chang, Huiyun; Zhang, Yongguang

    2017-08-01

    The potential diagnostic value of chemiluminescence immunoassays (CLIAs) has been accepted in recent years, although their use for foot-and-mouth disease (FMD) diagnostics has not been reported. Full-length 3ABC and 2C proteins were expressed in bacteria and purified by affinity chromatography to develop a rapid and accurate approach to distinguish pigs infected with foot-and-mouth disease virus (FMDV) from vaccinated pigs. The recombinant proteins were then used as antigens to develop two CLIAs for the detection of antibodies against nonstructural viral proteins. The diagnostic performance of the two assays was compared by analyzing serum from pigs (naive pigs, n = 63; vaccinated, uninfected pigs, n = 532; naive, infected pigs, n = 117) with a known infection status. The 3ABC-2C CLIA had a higher accuracy rate, with a diagnostic sensitivity of 100% and a diagnostic specificity of 96.5%, than the 3ABC CLIA, which had a diagnostic sensitivity of 95.7% and a diagnostic specificity of 96.0%. The results of the 3ABC-2C CLIA also had a high rate of concordance with those of two commercial FMDV enzyme-linked immunosorbent assay (ELISA) kits used to assess serum collected from 962 pigs in the field (96.2% and 97.8%, respectively). The 3ABC-2C CLIA detected infection in serum samples from infected pigs earlier than the commercial ELISA kits. In addition, the 3ABC-2C CLIA produced results within 15 min. On the basis of these findings, the 3ABC-2C CLIA could serve as the foundation for the development of penside FMD diagnostics and offers an alternative method to detect FMDV infections. Copyright © 2017 American Society for Microbiology.

  3. Quantitative electrical detection of immobilized protein using gold nanoparticles and gold enhancement on a biochip

    International Nuclear Information System (INIS)

    Lei, Kin Fong

    2011-01-01

    Electrical detection of the concentration of protein immobilized on a biochip is demonstrated. The concentration of the direct immobilized protein can be determined by the resistance values measured by an ohm-meter directly. Indium tin oxide interdigitated electrodes were utilized as the detection sites on the biochip. Protein, i.e. antibody, of certain concentration was first immobilized on the detection site. Gold nanoparticles were then applied to indicate the immobilized protein. Since the gold nanoparticles were tiny, a detectable electrical signal could not be generated. Hence, a gold enhancement process was performed for signal amplification. Gold nanoparticles were enlarged physically, such that a conductive metal layer was formed on the detection site. The presence and concentration of protein can be determined by the resistance value across the electrode measured by an ohm-meter. An immobilized protein concentration ranging from 50 to 1000 ng ml −1 can be detected quantitatively by the resistance values from 4300 to 1700 Ω. The proposed technique is potentially extended for the detection of immunoassay on the biochip. Since the protocol of the electrical detection does not involve sophisticated equipment, it can therefore be used for the development of a portable immunoassay device

  4. Report of the Workshop for Life Detection in Samples from Mars

    Science.gov (United States)

    Kminek, Gerhard; Conley, Catherine; Allen, Carlton C.; Bartlett, Douglas H.; Beaty, David W.; Benning, Liane G.; Bhartia, Rohit; Boston, Penelope J.; Duchaine, Caroline; Farmer, Jack D.; hide

    2014-01-01

    The question of whether there is or was life on Mars has been one of the most pivotal since Schiaparellis' telescopic observations of the red planet. With the advent of the space age, this question can be addressed directly by exploring the surface of Mars and by bringing samples to Earth for analysis. The latter, however, is not free of problems. Life can be found virtually everywhere on Earth. Hence the potential for contaminating the Mars samples and compromising their scientific integrity is not negligible. Conversely, if life is present in samples from Mars, this may represent a potential source of extraterrestrial biological contamination for Earth. A range of measures and policies, collectively termed 'planetary protection', are employed to minimise risks and thereby prevent undesirable consequences for the terrestrial biosphere. This report documents discussions and conclusions from a workshop held in 2012, which followed a public conference focused on current capabilities for performing life-detection studies on Mars samples. The workshop focused on the evaluation of Mars samples that would maximise scientific productivity and inform decision making in the context of planetary protection. Workshop participants developed a strong consensus that the same measurements could be employed to effectively inform both science and planetary protection, when applied in the context of two competing hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. Participants then outlined a sequence for sample processing and defined analytical methods that would test these hypotheses. They also identified critical developments to enable the analysis of samples from Mars.

  5. Enhanced Sensitive Immunoassay: Noncompetitive Phage Anti-Immune Complex Assay for the Determination of Malachite Green and Leucomalachite Green

    Science.gov (United States)

    2015-01-01

    To develop a more sensitive immunoassay for malachite green (MG) and leucomalachite green (LMG), we identified the immunocomplex binding phage-borne peptides for use in the noncompetitive phage anti-immunocomplex assay (PHAIA). An anti-LMG monoclonal antibody (mAb) was used to select immunocomplex binding peptides from a circular random eight-amino-acid phage-displayed library. After three rounds of panning-elution, five peptides that bound the LMG–mAb immunocomplex were obtained. One of the phage-borne peptide clones that resulted in an assay with the highest sensitivity was chosen for further research. The concentration of LMG producing 50% of the saturated signal and the limit of detection of the assay were 7.02 and 0.55 ng/mL, respectively, with a linear range of 1.35 to 21.56 ng/mL. The PHAIA based on the same antibody was 16 times more sensitive compared to the competitive immunoassay. PHAIA was used to analyze LMG, MG, and two mixtures of spiked fish samples, with validation by high-performance liquid chromatography (HPLC) with fluorescence detector. Results showed a good correlation (R2LMG = 0.9841; R2MG = 0.993; R2Mixture = 0.9903) between the data of PHAIA and HPLC, thus the assay was an efficient method for monitoring food safety. PMID:25077381

  6. Ferrocenyl-doped silica nanoparticles as an immobilized affinity support for electrochemical immunoassay of cancer antigen 15-3

    International Nuclear Information System (INIS)

    Hong Chenglin; Yuan Ruo; Chai Yaqin; Zhuo Ying

    2009-01-01

    The aim of this study is to elaborate a simple and sensitive electrochemical immunoassay using ferrocenecarboxylic (Fc-COOH)-doped silica nanoparticles (SNPs) as an immobilized affinity support for cancer antigen 15-3 (CA 15-3) detection. The Fc-COOH-doped SNPs with redox-active were prepared by using a water-in-oil microemulsion method. The use of colloidal silica could prevent the leakage of Fc-COOH and were easily modified with trialkoxysilane reagents for covalent conjugation of CA 15-3 antibodies (anti-CA 15-3). The Fc-COOH-doped SNPs were characterized by X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The fabrication process of the electrochemical immunosensor was demonstrated by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimal conditions, the developed immunosensor showed good linearity at the studied concentration range of 2.0-240 U mL -1 with a coefficient 0.9986 and a detection limit of 0.64 U mL -1 at S/N = 3

  7. Ferrocenyl-doped silica nanoparticles as an immobilized affinity support for electrochemical immunoassay of cancer antigen 15-3.

    Science.gov (United States)

    Hong, Chenglin; Yuan, Ruo; Chai, Yaqin; Zhuo, Ying

    2009-02-09

    The aim of this study is to elaborate a simple and sensitive electrochemical immunoassay using ferrocenecarboxylic (Fc-COOH)-doped silica nanoparticles (SNPs) as an immobilized affinity support for cancer antigen 15-3 (CA 15-3) detection. The Fc-COOH-doped SNPs with redox-active were prepared by using a water-in-oil microemulsion method. The use of colloidal silica could prevent the leakage of Fc-COOH and were easily modified with trialkoxysilane reagents for covalent conjugation of CA 15-3 antibodies (anti-CA 15-3). The Fc-COOH-doped SNPs were characterized by X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The fabrication process of the electrochemical immunosensor was demonstrated by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimal conditions, the developed immunosensor showed good linearity at the studied concentration range of 2.0-240 UmL(-1) with a coefficient 0.9986 and a detection limit of 0.64 UmL(-1) at S/N=3.

  8. Linkage of biomolecules to solid phases for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Topics covered by this lecture include a brief review of the principal methods of linkage of biomolecules to solid phase matrices. Copies of the key self explanatory slides are presented as figures together with reprints of two publications by the author dealing with a preferred chemistry for the covalent linkage of antibodies to hydroxyl and amino functional groups and the effects of changes in solid phase matrix and antibody coupling chemistry on the performance of a typical excess reagent immunoassay for thyroid stimulating hormone

  9. Competitive photometric enzyme immunoassay for fullerene C60 and its derivatives using a fullerene conjugated to horseradish peroxidase

    International Nuclear Information System (INIS)

    Hendrickson, Olga D.; Smirnova, Natalya I.; Zherdev, Anatoly V.; Dzantiev, Boris B.; Sveshnikov, Peter G.

    2016-01-01

    The article describes a highly sensitive single-step microplate enzyme immunoassay of the ELISA type for fullerene C 60 and its derivatives. Monoclonal anti-fullerene antibodies and a conjugate between fullerene and horseradish peroxidase were used as specific reagents. A direct competitive ELISA was carried out that was based on antibodies immobilized in the well of a microtiter plate, a peroxidase-labeled antigen, and detection via the dye formed from 3,3′,5,5′-tetramethylbenzidine and hydrogen peroxide. Both pristine fullerene C 60 and its water-soluble forms can be determined. The detection limits are 1.5 ng∙mL −1 for fullerene C 60 , and between 0.1 and 1.3 ng∙mL −1 for its derivatives. This ELISA format allows for almost two-fold reduction of the time needed for the assay in comparison to indirect scheme with labeled antibodies. (author)

  10. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    Directory of Open Access Journals (Sweden)

    Thomas Meyer

    2016-08-01

    Full Text Available The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT in medical samples. Nucleic acid amplification tests (NAATs are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM should include evaluation of lymphogranuloma venereum (LGV by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs or rapid diagnostic tests (RDTs are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  11. Diagnostic effectiveness of immunoassays systems for hepatitis C virus in samples from multi-transfusion patients

    International Nuclear Information System (INIS)

    Rivero Jimenez, Rene A; Merlin Linares, Julio C; Blanco de Armas, Madelin; Navea Leyva, Leonor M

    2009-01-01

    Hepatitis C virus (CHV) blood-transmission is a health problem in Cuba and in the world. Some types of diagnostic immunoassays have been developed for the blood certification and in general have a high diagnostic sensitivity and specificity in healthy donors. However, its behavior in samples from multi-transfusion patients could by less effective. To assess the diagnostic effectiveness of the UMELISA HCV third generation Cuban immunoassay (TecnoSUMA, S.A. La Habana), Cuba) in samples from multi-transfusion patients, in parallel, 335 sera from patients were processed by UBI HCV EIA 4.0 (United Biomedical, EE.UU) and UMELISA HCV third generation, and the samples with incongruous results were verified by PCR COBAS AmpliScreen HCV Test, v2 system (Roche, EE.UU.) Comparing the UMELISA HCV third generation system with the UBI HCV EIA 4.0 it was achieved a Sd of 95,8% CI(95%): 92,5-99,15 and a Ed of 100% CI (95%): 99,7-100, with IY: 0,96 (0,93-0,99) with k: 0,0582 ID (95%): 0,9276-0,9888, p = 0,000. Both immunoassay systems were satisfactory for immunodiagnosis of multi-transfusion patients

  12. Improved porous silicon (P-Si) microarray based PSA (prostate specific antigen) immunoassay by optimized surface density of the capture antibody

    Science.gov (United States)

    Lee, SangWook; Kim, Soyoun; Malm, Johan; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas

    2014-01-01

    Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5ngmL−1, 80pgmL−1, and 800fgmL−1 when arraying the PSA antibody, H117 at the concentration 15µgmL−1, 35µgmL−1 and 154µgmL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800fgmL−1 to 500ngmL−1. The microarray showed a LOD of 800fgmL−1 and a dynamic range of 800 fgmL−1 to 80ngmL−1 in serum spiked samples. PMID:24016590

  13. The most conserved genome segments for life detection on Earth and other planets.

    Science.gov (United States)

    Isenbarger, Thomas A; Carr, Christopher E; Johnson, Sarah Stewart; Finney, Michael; Church, George M; Gilbert, Walter; Zuber, Maria T; Ruvkun, Gary

    2008-12-01

    On Earth, very simple but powerful methods to detect and classify broad taxa of life by the polymerase chain reaction (PCR) are now standard practice. Using DNA primers corresponding to the 16S ribosomal RNA gene, one can survey a sample from any environment for its microbial inhabitants. Due to massive meteoritic exchange between Earth and Mars (as well as other planets), a reasonable case can be made for life on Mars or other planets to be related to life on Earth. In this case, the supremely sensitive technologies used to study life on Earth, including in extreme environments, can be applied to the search for life on other planets. Though the 16S gene has become the standard for life detection on Earth, no genome comparisons have established that the ribosomal genes are, in fact, the most conserved DNA segments across the kingdoms of life. We present here a computational comparison of full genomes from 13 diverse organisms from the Archaea, Bacteria, and Eucarya to identify genetic sequences conserved across the widest divisions of life. Our results identify the 16S and 23S ribosomal RNA genes as well as other universally conserved nucleotide sequences in genes encoding particular classes of transfer RNAs and within the nucleotide binding domains of ABC transporters as the most conserved DNA sequence segments across phylogeny. This set of sequences defines a core set of DNA regions that have changed the least over billions of years of evolution and provides a means to identify and classify divergent life, including ancestrally related life on other planets.

  14. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform.

    Science.gov (United States)

    Tripathy, Rajesh K; Zamora-Mendez, Alejandro; de la O Serna, José A; Paternina, Mario R Arrieta; Arrieta, Juan G; Naik, Ganesh R

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  15. Detection of Rabies antigen in brains of suspected Rabid dogs ...

    African Journals Online (AJOL)

    Objective: To detect the presence of rabies antigen in brains of suspected rabid dogs. Materials and Methods: Ninety six (96) brain specimens from suspected rabid dogs were examined for the presence of rabies antigen using Seller's staining technique and enzyme immunoassay. Results: The two techniques were both ...

  16. Development and analytical performance of a new ARCHITECT automated dipeptidyl peptidase-4 immunoassay

    Directory of Open Access Journals (Sweden)

    Philip M. Hemken

    2017-12-01

    Full Text Available Background: Dipeptidyl peptidase-4 (DPP-4 may be a suitable biomarker to identify people with severe asthma who have greater activation of the interleukin-13 (IL-13 pathway and may therefore benefit from IL-13-targeted treatments. We report the analytical performance of an Investigational Use Only immunoassay and provide data on the biological range of DPP-4 concentrations. Methods: We assessed assay performance, utilising analyses of precision, linearity and sensitivity; interference from common endogenous assay interferents, and from asthma and anti-diabetic medications, were also assessed. The assay was used to measure the range of serum DPP-4 concentrations in healthy volunteers and subjects with diabetes and severe, uncontrolled asthma. Results: The total precision of DPP-4 concentration measurement (determined using percentage coefficient of variation was ≤5% over 20 days. Dilution analysis yielded linear results from 30 to 1305 ng/mL; the limit of quantitation was 19.2 ng/mL. No notable endogenous or drug interferences were observed at the expected therapeutic concentration. Median DPP-4 concentrations in healthy volunteers and subjects with asthma or Type 1 diabetes were assessed, with concentrations remaining similar in subjects with diabetes and asthma across different demographics. Conclusion: These analyses indicate that the ARCHITECT DPP-4 Immunoassay is a reliable and robust method for measuring serum DPP-4 concentration. Keywords: Asthma, Automated immunoassay, Biomarker, Dipeptidyl peptidase-4, IL-13

  17. Comparison of clinical performance of antigen based-enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-PCR for detection of genital Chlamydia trachomatis infection.

    Science.gov (United States)

    Nateghi Rostami, Mahmoud; Hossein Rashidi, Batool; Aghsaghloo, Fatemeh; Nazari, Razieh

    2016-06-01

    Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Performances of enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-polymerase chain reaction (PCR) for diagnosis of genital C.trachomatis infection in women were compared. In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs) who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS) antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. In total, 37 (7.14%) cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMP-PCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48). C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  18. Development of a highly sensitive and specific immunoassay for enrofloxacin based on heterologous coating haptens.

    Science.gov (United States)

    Wang, Zhanhui; Zhang, Huiyan; Ni, Hengjia; Zhang, Suxia; Shen, Jianzhong

    2014-04-11

    In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L(-1) to as low as 0.07 μg L(-1). The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Tuberculin purified protein derivative (PPD) immunoassay as an in vitro alternative assay for identity and confirmation of potency.

    Science.gov (United States)

    Ho, Mei M; Kairo, Satnam K; Corbel, Michael J

    2006-01-01

    Tuberculin purified protein derivative (PPD) currently can only be standardised by delayed hypersensitivity skin reactions in sensitised guinea pigs. An in vitro dot blot immunoassay was developed for both identity and confirmation of potency estimation of PPD. Polyclonal antibodies (mainly IgG) were generated and immunoreacted with human, bovine and, to lesser extent, avian PPD preparations. Combining size exclusion chromatography (FPLC-SEC) and dot blot immunoassay, the results showed that PPD preparations were mixtures of very heterogeneous tuberculoproteins ranging in size from very large aggregates to very small degraded molecules. All individual fractions of PPD separated by size were immunoreactive, although those of the largest molecular sizes appeared the most immunoreactive in this in vitro dot blot immunoassay. This method is very sensitive and specific to tuberculoproteins and can be an in vitro alternative for the in vivo intradermal skin assay which uses guinea pigs for identity of PPD preparations. Although the capacity of PPD to elicit cell-mediated immune responses on intradermal testing has to be confirmed by in vivo assay, the dot blot immunoassay offers a rapid, sensitive and animal-free alternative to in vivo testing for confirming the identity of PPD preparations with appropriate potencies. This alternative assay would be particularly useful for national regulatory laboratories for confirming the data of manufacturers and thus reducing the use of animals.

  20. Homogeneous immunoassay for the cancer marker alpha-fetoprotein using single wavelength excitation fluorescence cross-correlation spectroscopy and CdSe/ZnS quantum dots and fluorescent dyes as labels

    International Nuclear Information System (INIS)

    Wang, Jinjie; Liu, Heng; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    The article describes sensitive and selective homogeneous immunoassays for the liver cancer biomarker alpha-fetoprotein (AFP) in human serum by using single wavelength excitation fluorescence cross-correlation spectroscopy (SW-FCCS). Both competitive and sandwich immunoassay modes were applied, and AFP served as a model analyte. Fluorescent CdSe/ZnS quantum dots (with a 655 nm emission peak) and the fluorophore Alexa Fluor 488 (520 nm emission) were chosen to label the antibodies in the sandwich mode, and the antibody and the antigen in the competitive mode. Under optimized conditions, the sandwich assay has a linear dynamic range that covers the 20 pM to 5.0 nM concentration range. The competitive assay, in turn, extends from 180 pM to 15.0 nM. The respective detection limits are 20 pM and 180 pM. The method was successfully applied to directly determine AFP in (spiked) clinical samples, and results were in good agreement with data obtained via ELISAs. (author)

  1. Detection and differentiation of 22kDa and 20kDa Growth Hormone proteoforms in human plasma by LC-MS/MS

    DEFF Research Database (Denmark)

    Sanmartín, Gerard Such; Bache, N.; Bosch, J.

    2015-01-01

    Human growth hormone (GH) is suspected to be widely and illegally used in sport to improve athletes' performance. For the detection of GH abuse, blood samples are screened for abnormal ratios between the 22 and 20kDa GH proteoforms that demonstrate the administration of the synthetic hormone....... Current detection methods are based on classical immunoassays as they provide sufficient sensitivity for the detection of GH proteoforms. These antibody based methods, however, suffer from unclear selectivity and potential cross-reactivity towards similar proteins. For unambiguous GH detection, we report...... a Mass Spectrometry ImmunoAssay (MSIA) that first enriches GH from plasma with an antibody of relatively low specificity, and subsequently quantifies the 22 and 20kDa proteoforms by Selected Reaction Monitoring (SRM) LC-MS/MS analysis. This method proved superior to an antibody-free strategy based on GH...

  2. Parallel workflow for high-throughput (>1,000 samples/day quantitative analysis of human insulin-like growth factor 1 using mass spectrometric immunoassay.

    Directory of Open Access Journals (Sweden)

    Paul E Oran

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker for the management of growth hormone disorders. Recently there has been rising interest in deploying mass spectrometric (MS methods of detection for measuring IGF1. However, widespread clinical adoption of any MS-based IGF1 assay will require increased throughput and speed to justify the costs of analyses, and robust industrial platforms that are reproducible across laboratories. Presented here is an MS-based quantitative IGF1 assay with performance rating of >1,000 samples/day, and a capability of quantifying IGF1 point mutations and posttranslational modifications. The throughput of the IGF1 mass spectrometric immunoassay (MSIA benefited from a simplified sample preparation step, IGF1 immunocapture in a tip format, and high-throughput MALDI-TOF MS analysis. The Limit of Detection and Limit of Quantification of the resulting assay were 1.5 μg/L and 5 μg/L, respectively, with intra- and inter-assay precision CVs of less than 10%, and good linearity and recovery characteristics. The IGF1 MSIA was benchmarked against commercially available IGF1 ELISA via Bland-Altman method comparison test, resulting in a slight positive bias of 16%. The IGF1 MSIA was employed in an optimized parallel workflow utilizing two pipetting robots and MALDI-TOF-MS instruments synced into one-hour phases of sample preparation, extraction and MSIA pipette tip elution, MS data collection, and data processing. Using this workflow, high-throughput IGF1 quantification of 1,054 human samples was achieved in approximately 9 hours. This rate of assaying is a significant improvement over existing MS-based IGF1 assays, and is on par with that of the enzyme-based immunoassays. Furthermore, a mutation was detected in ∼1% of the samples (SNP: rs17884626, creating an A→T substitution at position 67 of the IGF1, demonstrating the capability of IGF1 MSIA to detect point mutations and posttranslational modifications.

  3. Electron spin resonance spectroscopy for immunoassay using iron oxide nanoparticles as probe.

    Science.gov (United States)

    Jiang, Jia; Tian, Sizhu; Wang, Kun; Wang, Yang; Zang, Shuang; Yu, Aimin; Zhang, Ziwei

    2018-02-01

    With the help of iron oxide nanoparticles, electron spin resonance spectroscopy (ESR) was applied to immunoassay. Iron oxide nanoparticles were used as the ESR probe in order to achieve an amplification of the signal resulting from the large amount of Fe 3+ ion enclosed in each nanoparticle. Rabbit IgG was used as antigen to test this method. Polyclonal antibody of rabbit IgG was used as antibody to detect the antigen. Iron oxide nanoparticle with a diameter of either 10 or 30 nm was labeled to the antibody, and Fe 3+ in the nanoparticle was probed for ESR signal. The sepharose beads were used as solid phase to which rabbit IgG was conjugated. The nanoparticle-labeled antibody was first added in the sample containing antigen, and the antigen-conjugated sepharose beads were then added into the sample. The nanoparticle-labeled antibody bound to the antigen on sepharose beads was separated from the sample by centrifugation and measured. We found that the detection ranges of the antigen obtained with nanoparticles of different sizes were different because the amount of antibody on nanoparticles of 10 nm was about one order of magnitude higher than that on nanoparticles of 30 nm. When 10 nm nanoparticle was used as probe, the upper limit of detection was 40.00 μg mL -1 , and the analytical sensitivity was 1.81 μg mL -1 . When 30 nm nanoparticle was used, the upper limit of detection was 3.00 μg mL -1 , and the sensitivity was 0.014 and 0.13 μg mL -1 depending on the ratio of nanoparticle to antibody. Graphical abstract Schematic diagram of procedure and ESR spectra.

  4. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water.

    Science.gov (United States)

    Yu, Hye-Weon; Jang, Am; Kim, Lan Hee; Kim, Sung-Jo; Kim, In S

    2011-09-15

    Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.

  5. Magnetic immunoassay using CdSe/ZnS quantum dots as fluorescent probes to detect the level of DNA methyltransferase 1 in human serum sample

    Directory of Open Access Journals (Sweden)

    Yu F

    2018-01-01

    Full Text Available Fei Yu,1,* Ya-min Xiong,1,* Song-cheng Yu,1 Lei-liang He,1 Shan-shan Niu,1 Yu-ming Wu,1 Jie Liu,1 Ling-bo Qu,2 Li-e Liu,1 Yong-jun Wu1 1College of Public Health, 2College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, Henan, People’s Republic of China *These authors contributed equally to this work Background: DNA methyltransferase 1 (DNMT1, a dominant enzyme responsible for the transfer of a methyl group from the universal methyl donor to the 5-position of cytosine residues in DNA, is essential for mammalian development and closely related to cancer and a variety of age-related chronic diseases. DNMT1 has become a useful biomarker in early disease diagnosis and a potential therapeutic target in cancer therapy and drug development. However, till now, most of the studies on DNA methyltransferase (MTase detection have focused on the prokaryote MTase and its activity.Methods: A magnetic fluorescence-linked immunosorbent assay (FLISA using CdSe/ZnS quantum dots as fluorescent probes was proposed for the rapid and sensitive detection of the DNMT1 level in this study. Key factors that affect the precision and accuracy of the determination of DNMT1 were optimized.Results: Under the optimal conditions, the limit of detection was 0.1 ng/mL, the linear range was 0.1–1,500 ng/mL, the recovery was 91.67%–106.50%, and the relative standard deviations of intra- and inter-assays were respectively 5.45%–11.29% and 7.03%–11.25%. The cross-reactivity rates with DNA methyltransferases 3a and 3b were only 4.0% and 9.4%, respectively. Furthermore, FLISA was successfully used to detect the levels of DNMT1 in human serum samples, and compared with commercial enzyme-linked immunosorbent assay (ELISA kits. The results revealed that there was a good correlation between FLISA and commercial ELISA kits (correlation coefficient r=0.866, p=0.001. The linear scope of FLISA was broader than ELISA, and the measurement time was much shorter

  6. Disequilibrium biosignatures over Earth history and implications for detecting exoplanet life.

    Science.gov (United States)

    Krissansen-Totton, Joshua; Olson, Stephanie; Catling, David C

    2018-01-01

    Chemical disequilibrium in planetary atmospheres has been proposed as a generalized method for detecting life on exoplanets through remote spectroscopy. Among solar system planets with substantial atmospheres, the modern Earth has the largest thermodynamic chemical disequilibrium due to the presence of life. However, how this disequilibrium changed over time and, in particular, the biogenic disequilibria maintained in the anoxic Archean or less oxic Proterozoic eons are unknown. We calculate the atmosphere-ocean disequilibrium in the Precambrian using conservative proxy- and model-based estimates of early atmospheric and oceanic compositions. We omit crustal solids because subsurface composition is not detectable on exoplanets, unlike above-surface volatiles. We find that (i) disequilibrium increased through time in step with the rise of oxygen; (ii) both the Proterozoic and Phanerozoic may have had remotely detectable biogenic disequilibria due to the coexistence of O 2 , N 2 , and liquid water; and (iii) the Archean had a biogenic disequilibrium caused by the coexistence of N 2 , CH 4 , CO 2 , and liquid water, which, for an exoplanet twin, may be remotely detectable. On the basis of this disequilibrium, we argue that the simultaneous detection of abundant CH 4 and CO 2 in a habitable exoplanet's atmosphere is a potential biosignature. Specifically, we show that methane mixing ratios greater than 10 -3 are potentially biogenic, whereas those exceeding 10 -2 are likely biogenic due to the difficulty in maintaining large abiotic methane fluxes to support high methane levels in anoxic atmospheres. Biogenicity would be strengthened by the absence of abundant CO, which should not coexist in a biological scenario.

  7. A Miniaturized Impedimetric Immunosensor for the Competitive Detection of Adrenocorticotropic Hormone

    Directory of Open Access Journals (Sweden)

    Nan Li

    2017-12-01

    Full Text Available Adrenocorticotropic hormone (ACTH plays an essential role in regulating corticosteroid hormone production, which has important functions in a myriad of critical physiological functions. In this proof-of-concept study, a miniaturized immunosensor was developed for the highly sensitive detection of ACTH using electrochemical impedance spectroscopy (EIS in connection with disposable screen-printed gold electrodes (SPGEs. A film of 3,3′-dithiobis[sulfosuccinimidylpropionate] (DTSSP was prepared to immobilize anti-ACTH antibodies covalently on the nanostructured SPGE surface. The surface-immobilized anti-ACTH antibodies captured the biotinylated ACTH (biotin-ACTH and non-labelled ACTH for the competitive immunoassay. After coupling of a streptavidin-alkaline phosphatase conjugate (Streptavidin-ALP, the bio-catalysed precipitation of an insoluble and insulating product onto the sensing interface changed the charge transfer resistance (Rct characteristics significantly. The detection limit of 100 fg/mL was determined for ACTH in a 5 μL sample volume, which indicated that this versatile platform can be easily adapted for miniaturized electrochemical immunosensing of cancer marker biomolecules. High selectivity and sensitivity of our immunoassay to detect ACTH in real samples demonstrated its promising potential for future development and applications using clinical samples.

  8. Comparison of Salivary and Serum Enzyme Immunoassays for the Diagnosis of Helicobacter pylori Infection

    Directory of Open Access Journals (Sweden)

    John M Embil

    1998-01-01

    Full Text Available Infection with Helicobacter pylori has been established as an important risk factor for the development of peptic ulcer disease, gastritis and gastric cancer. The diagnosis of H pylori infection can be established by invasive or noninvasive techniques. Two noninvasive enzyme immunoassays (EIAs for antibody detection – HeliSal and Pylori Stat – were compared with histology. Both assays detect immunoglobulin (Ig G directed against purified H pylori antigen. The test populations consisted of 104 consecutive patients scheduled for upper gastrointestinal endoscopy. Of these patients, 97 (93% had symptoms compatible with peptic ulcer disease. Saliva and serum were collected simultaneously at the time of endoscopy. Salivary EIA had a sensitivity of 66%, specificity of 67%, positive predictive value of 67% and negative predictive value of 66% compared with the serum EIA, where the results were 98%, 48%, 64% and 96%, respectively. Although the salivary EIA is an appealing noninvasive test, it was not a sensitive and specific assay. The serum EIA also lacked specificity, but was highly sensitive with a good negative predictive value. Although a negative serum EIA rules out H pylori infection, a positive result must be interpreted in the clinical context and confirmed with a more specific measure.

  9. Determination of Glutamic Acid Decarboxylase (GAD65 in Pancreatic Islets and Its In Vitro and In Vivo Degradation Kinetics in Serum Using a Highly Sensitive Enzyme Immunoassay

    Directory of Open Access Journals (Sweden)

    Michael Schlosser

    2008-01-01

    Full Text Available Glutamic acid decarboxylase GAD65 autoantibodies (GADA are an established marker for autoimmune diabetes. Recently, the autoantigen GAD65 itself was proposed as biomarker of beta-cell loss for prediction of autoimmune diabetes and graft rejection after islet transplantation. Therefore, the GAD65 content in pancreatic islets of different species and its serum degradation kinetics were examined in this study using a sensitive immunoassay. GAD65 was found in quantities of 78 (human, 43.7 (LEW.1A rat and 37.4 (BB/OK rat ng per 1,000 islets, respectively, but not in mouse islets. The in vitro half-life of porcine GAD65 and human recombinant GAD65 ranged from 1.27 to 2.35 hours at 37°C in human serum, plasma and blood, and was unaffected by presence of GAD65 autoantibodies. After injecting 2,000 ng recombinant human GAD65 into LEW.1A rats, the in vivo half-life was 2.77 hours. GAD65 was undetectable after 24 hours in these animals, and for up to 48 hours following diabetes induction by streptozotocin in LEW.1A rats. Estimated from these data, at least 13 islets in rat and 1,875 in human must be simultaneously destroyed to detect GAD65 in circulation. These results should be taken into consideration in further studies aimed at examining the diagnostic relevance of GAD65.

  10. Simultaneous detection of indicators of hepatitis virus exposure

    International Nuclear Information System (INIS)

    Ling, C.; Decker, R.A.; Overby, L.R.

    1981-01-01

    This invention discloses an improvement in solid phase immunoassay methods for the detection and determination of antigens and antibodies (markers) relating to hepatitis. The method for simultaneously detecting in a sample at least two different markers evidencing exposure to hepatitis virus comprises contacting the sample with a solid phase reagent which is coated with at least two different, non-complementary immunoreactants which are complementary to the unknown markers to be detected, then with a liquid reagent comprising at least two different hepatitis markers or immunoreactants, each selected to either react or compete with one of the unknown markers and each labeled with a detectably distinct tag. Examples described use 125 I. (author)

  11. Oriented antibody immobilization to polystyrene macrocarriers for immunoassay modified with hydrazide derivatives of poly(methacrylic acid

    Directory of Open Access Journals (Sweden)

    Vinokurova Ludmila G

    2001-08-01

    Full Text Available Abstract Background Hydrophobic polystyrene is the most common material for solid phase immunoassay. Proteins are immobilized on polystyrene by passive adsorption, which often causes considerable denaturation. Biological macromolecules were found to better retain their functional activity when immobilized on hydrophilic materials. Polyacrylamide is a common material for solid-phase carriers of biological macromolecules, including immunoreagents used in affinity chromatography. New macroformats for immunoassay modified with activated polyacrylamide derivatives seem to be promising. Results New polymeric matrices for immunoassay in the form of 0.63-cm balls which contain hydrazide functional groups on hydrophilic polymer spacer arms at their surface shell are synthesized by modification of aldehyde-containing polystyrene balls with hydrazide derivatives of poly(methacrylic acid. The beads contain up to 0.31 μmol/cm2 active hydrazide groups accessible for covalent reaction with periodate-oxidized antibodies. The matrices obtained allow carrying out the oriented antibody immobilization, which increases the functional activity of immunosorbents. Conclusions An efficient site-directed antibody immobilization on a macrosupport is realized. The polymer hydrophilic spacer arms are the most convenient and effective tools for oriented antibody coupling with molded materials. The suggested scheme can be used for the modification of any other solid supports containing electrophilic groups reacting with hydrazides.

  12. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    Science.gov (United States)

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  13. Disequilibrium biosignatures over Earth history and implications for detecting exoplanet life

    Science.gov (United States)

    Krissansen-Totton, Joshua; Olson, Stephanie; Catling, David C.

    2018-01-01

    Chemical disequilibrium in planetary atmospheres has been proposed as a generalized method for detecting life on exoplanets through remote spectroscopy. Among solar system planets with substantial atmospheres, the modern Earth has the largest thermodynamic chemical disequilibrium due to the presence of life. However, how this disequilibrium changed over time and, in particular, the biogenic disequilibria maintained in the anoxic Archean or less oxic Proterozoic eons are unknown. We calculate the atmosphere-ocean disequilibrium in the Precambrian using conservative proxy- and model-based estimates of early atmospheric and oceanic compositions. We omit crustal solids because subsurface composition is not detectable on exoplanets, unlike above-surface volatiles. We find that (i) disequilibrium increased through time in step with the rise of oxygen; (ii) both the Proterozoic and Phanerozoic may have had remotely detectable biogenic disequilibria due to the coexistence of O2, N2, and liquid water; and (iii) the Archean had a biogenic disequilibrium caused by the coexistence of N2, CH4, CO2, and liquid water, which, for an exoplanet twin, may be remotely detectable. On the basis of this disequilibrium, we argue that the simultaneous detection of abundant CH4 and CO2 in a habitable exoplanet’s atmosphere is a potential biosignature. Specifically, we show that methane mixing ratios greater than 10−3 are potentially biogenic, whereas those exceeding 10−2 are likely biogenic due to the difficulty in maintaining large abiotic methane fluxes to support high methane levels in anoxic atmospheres. Biogenicity would be strengthened by the absence of abundant CO, which should not coexist in a biological scenario. PMID:29387792

  14. Astrobiology's Central Dilemma: How can we detect Life if we cannot even Define it?

    Science.gov (United States)

    Clark, B. C.

    2001-11-01

    Culling and consolidating from a collection of 102 attributes asserted as properties of Life, and the numerous Definitions of Life which invoke them, a new definition is proposed. Analysis of the pathways to proving that any given entity, from micro-sample to planetary object, harbors one or more lifeforms provides strategies for the observations, experiments and detection approaches. These are necessarily varied because of the relative accessibility/inaccessibility of the samples themselves, for example, from Mars, Europa, the ancient Earth or extra-solar system planets. A two-tiered Definition of Life has been formulated, involving both Lifeform and Organism. Devising exploration strategies with a reasonable probability of success and acceptance should proceed along the steps needed for detection and verification of the minimal properties which define Life itself. Multiple approaches, such as high resolution remote spectroscopy for detection of biomarker gases, in situ demonstrations of energy utilization to performs functions such as anabolic or catabolic transformations, achievement of demonstrated reproduction through multi-condition incubations, and probes for macromolecular biochemicals which indicate information storage should be undertaken wherever possible, as should return of samples to terrestrial laboratories for more versatile, more sensitive and more definitive examinations. Use of control samples is paramount, as is detailed understanding of the chemistry and physics of the environment which constrains the activities and tracers being sought.

  15. Fluorescent Silica Nanoparticles in the Detection and Control of the Growth of Pathogen

    International Nuclear Information System (INIS)

    Chitra, K.; Annadurai, G.

    2013-01-01

    In this present study the bio conjugated fluorescent silica nanoparticles give an efficient fluorescent-based immunoassay for the detection of pathogen. The synthesized silica nanoparticles were poly dispersed and the size of the silica nanoparticles was in the range of 114-164 nm. The energy dispersive X-ray spectrophotometer showed the presence of silica at 1.8 keV and the selected area diffractometer showed amorphous nature of silica nanoparticles. The FTIR spectrum confirmed the attachment of dye and carboxyl group onto the silica nanoparticles surface. The fluorescent silica nanoparticles showed highly efficient fluorescence and the fluorescent emission of silica nanoparticles occurred at 536 nm. The SEM image showed the aggregation of nanoparticles and bacteria. The growth of the pathogenic E. coli was controlled using silica nanoparticles; therefore silica nanoparticles could be used in food packaging material, biomedical material, and so forth. This work provides a rapid, simple, and accurate method for the detection of pathogen using fluorescent-based immunoassay.

  16. Faraday cage-type electrochemiluminescence immunosensor for ultrasensitive detection of Vibrio vulnificus based on multi-functionalized graphene oxide.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Yu, Zhongqing; Tao, Yingying; Wu, Yanjie; Zeng, Min; Wang, Sui; Li, Xing; Zhou, Jun; Su, Xiurong

    2016-10-01

    A novel Faraday cage-type electrochemiluminescence (ECL) immunosensor devoted to the detection of Vibrio vulnificus (VV) was fabricated. The sensing strategy was presented by a unique Faraday cage-type immunocomplex based on immunomagnetic beads (IMBs) and multi-functionalized graphene oxide (GO) labeled with (2,2'-bipyridine)(5-aminophenanthroline)ruthenium (Ru-NH2). The multi-functionalized GO could sit on the electrode surface directly due to the large surface area, abundant functional groups, and good electronic transport property. It ensures that more Ru-NH2 is entirely caged and become "effective," thus improving sensitivity significantly, which resembles extending the outer Helmholtz plane (OHP) of the electrode. Under optimal conditions, the developed immunosensor achieves a limit of detection as low as 1 CFU/mL. Additionally, the proposed immunosensor with high sensitivity and selectivity can be used for the detection of real samples. The novel Faraday cage-type method has shown potential application for the diagnosis of VV and opens up a new avenue in ECL immunoassay. Graphical abstract Faraday cage-type immunoassay mode for ultrasensitive detection by extending OHP.

  17. Nucleic Acid Extraction from Synthetic Mars Analog Soils for in situ Life Detection.

    Science.gov (United States)

    Mojarro, Angel; Ruvkun, Gary; Zuber, Maria T; Carr, Christopher E

    2017-08-01

    Biological informational polymers such as nucleic acids have the potential to provide unambiguous evidence of life beyond Earth. To this end, we are developing an automated in situ life-detection instrument that integrates nucleic acid extraction and nanopore sequencing: the Search for Extra-Terrestrial Genomes (SETG) instrument. Our goal is to isolate and determine the sequence of nucleic acids from extant or preserved life on Mars, if, for example, there is common ancestry to life on Mars and Earth. As is true of metagenomic analysis of terrestrial environmental samples, the SETG instrument must isolate nucleic acids from crude samples and then determine the DNA sequence of the unknown nucleic acids. Our initial DNA extraction experiments resulted in low to undetectable amounts of DNA due to soil chemistry-dependent soil-DNA interactions, namely adsorption to mineral surfaces, binding to divalent/trivalent cations, destruction by iron redox cycling, and acidic conditions. Subsequently, we developed soil-specific extraction protocols that increase DNA yields through a combination of desalting, utilization of competitive binders, and promotion of anaerobic conditions. Our results suggest that a combination of desalting and utilizing competitive binders may establish a "universal" nucleic acid extraction protocol suitable for analyzing samples from diverse soils on Mars. Key Words: Life-detection instruments-Nucleic acids-Mars-Panspermia. Astrobiology 17, 747-760.

  18. Determination of phospholipid transfer proteins in rat tissues by immunoassays

    International Nuclear Information System (INIS)

    Teerlink, T.

    1983-01-01

    Several quantitative immunoassays have been developed for two phospholipid transfer proteins from rat liver, i.e. the phosphatidylcholine transfer protein and the non-specific lipid transfer protein. The development of a double-antibody radioimmunoassay for the phosphatidylcholine transfer protein is described. The transfer protein was labelled with iodine-125 by the mild glucose oxidase-lactoperoxidase method. Although less than one tyrosine residue per molecule of transfer protein was labelled, only 20% of the labelled transfer protein was immunoprecipitable. This value could be increased to 80% by purifying the labelled protein by affinity chromatography on a column of anti-phosphatidylcholine transfer protein-IgG coupled to Sepharose 4B. The radioimmunoassay was used to determine the levels of phosphatidylcholine transfer protein in homogenates and 105 000 xg supernatants from various rat tissues as well as several Morris hepatomas. An enzyme immunoassay for the non-specific lipid transfer protein is also described. The antiserum that was raised especially by the author was cross-reactive with the non-specific lipid transfer protein present in 105 000 xg supernatants from human, mouse and bovine liver. The non-specific lipid transfer protein lost its immunoreactivity upon labelling with iodine-125 using different labelling techniques. Therefore, a regular radioimmunoassay could not be developed. The results of these different assays were compared. (Auth.)

  19. Radio-immunoassays for glucagon-like peptides 1 and 2 (GLP-1 and GLP-2)

    DEFF Research Database (Denmark)

    Orskov, C; Holst, J J

    1987-01-01

    Gene-sequencing studies have shown that the glucagon precursor contains two additional glucagon-like sequences, the so-called glucagon-like peptides 1 and 2 (GLP-1 and GLP-2). We developed radio-immunoassays against synthetic peptides corresponding to these sequences. Antisera were raised in rabb...

  20. Monoclonal antibody-based broad-specificity immunoassay for monitoring organophosphorus pesticides in environmental water samples

    Science.gov (United States)

    The extensive use of organophosphorus pesticides (OPs) in agriculture and domestic settings can result in widespread water contamination. The development of easy-to-use and rapid-screening immunoassay methods in a class-selective manner is a topic of considerable environmental interest. In this wo...