WorldWideScience

Sample records for imaging false-positive study

  1. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  2. False positive paediatric labelled white blood cell study

    International Nuclear Information System (INIS)

    Beveridge, N.; Bennett, E.; Thomas, P.

    2002-01-01

    Full text: An eight-month-old female presented for a technetium labelled white blood cell study (LWBC) to exclude an intra-abdominal abscess. Born premature, the child had surgery to repair a perforated bowel and had repeated presentations with diarrhoea, fevers, a tender right upper quadrant and a raised leucocyte count. Multiple imaging modalities failed to demonstrate recurrent bowel perforation, ischaemia or an intra-abdominal mass. A LWBC study was performed with whole body imaging at 1 and 5 hours post re-injection of the radiolabelled blood. No abnormal uptake was visualised in the abdomen but abnormal white cell accumulation was noted in the right hind foot and the length of the right lower leg. This activity appeared to lie along the course of the right tibia. Plain X-ray demonstrated no evidence of tibial osteomyelitis. Concern that the LWBC may be falsely negative in a patient on antibiotics, a gallium scan was immediately performed to re-examine the abdomen. The whole body gallium images demonstrated normal physiological uptake in the abdomen and no evidence of infection in the right leg. The patient had no clinical features to support right leg pathology. The abnormal LWBC localisation in the right lower leg/foot was therefore falsely positive. The most likely explanation is increased activation of the autologous LWBC by 'rough' handling during difficult venesection and re-injection through small veins and needles/cannulas. The slow flow through the veins draining the foot injection site would contribute to margination in these vessel walls. This is a potential cause for false positive LWBC studies- with significant implications for patient care. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  4. Image Watermarking Scheme for Specifying False Positive Probability and Bit-pattern Embedding

    Science.gov (United States)

    Sayama, Kohei; Nakamoto, Masayoshi; Muneyasu, Mitsuji; Ohno, Shuichi

    This paper treats a discrete wavelet transform(DWT)-based image watermarking with considering the false positive probability and bit-pattern embedding. We propose an iterative embedding algorithm of watermarking signals which are K sets pseudo-random numbers generated by a secret key. In the detection, K correlations between the watermarked DWT coefficients and watermark signals are computed by using the secret key. L correlations are made available for the judgment of the watermark presence with specified false positive probability, and the other K-L correlations are corresponding to the bit-pattern signal. In the experiment, we show the detection results with specified false positive probability and the bit-pattern recovery, and the comparison of the proposed method against JPEG compression, scaling down and cropping.

  5. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  6. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  7. Diagnostic Invasiveness and Psychosocial Consequences of False-Positive Mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert Dirk; Brodersen, John

    2015-01-01

    PURPOSE: We undertook a study to assess whether women with false-positivemammography have worse psychosocial consequences if managed with aworkup that involves a biopsy (invasive group) than if managed with only additional imaging (noninvasive group). METHODS: We performed subgroup analysis...... of a cohort study of 454 womenwith abnormal screening mammography and 908 matched control women withnormal results. Using a condition-specific questionnaire (Consequences of Screening in Breast Cancer), we assessed 12 psychosocial consequences at 5 time points (0, 1, 6, 18, and 36 months after final diagnosis......) and compared the 2 groups of women with false-positives (invasive and noninvasive management groups). RESULTS: Among the 252 women with false-positive mammography eligible forthis study, psychosocial consequences were similar for those managed invasivelyand those managed noninvasively during the 36 months...

  8. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  9. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  10. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    Science.gov (United States)

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  11. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  12. The problem of false positives and false negatives in violent video game experiments.

    Science.gov (United States)

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. False Positive and False Negative Effects on Network Attacks

    Science.gov (United States)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  14. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  15. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  16. Consequences of a false-positive mammography result

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Bæksted, Christina; Vejborg, Ilse

    2016-01-01

    group used anxiolytic and antidepressant drugs. There was no difference in use of beta blockers. Hormone therapy was used more frequently by the false-positive, 36.6% versus 28.7%. The proportion of women using anxiolytic and antidepressant drugs increased with 19% from the before to the after period...... in the false-positive group, and with 16% in the normal group, resulting in an RRR of 1.02 (95% CI 0.92-1.14). RRR was 1.03 for beta blockers, 0.97 for hormone therapy. Conclusion(s): Drugs used to mitigate mood disorders were used more frequently by women with false-positive than by women with normal......Background: Previous research showed women experiencing false-positive mammograms to have greater anxiety about breast cancer than women with normal mammograms. To elucidate psychological effects of false-positive mammograms, we studied impact on drug intake.  Methods: We calculated the ratio...

  17. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  18. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  19. False positive seroreactivity to brucellosis in tuberculosis patients: a prevalence study

    Directory of Open Access Journals (Sweden)

    Mojtaba Varshochi

    2011-03-01

    Full Text Available Mojtaba Varshochi1,2, Jafar Majidi2, Marjan Amini1, Kamyar Ghabili3, Mohammadali M Shoja31Department of Infectious Disease, Tabriz University of Medical Sciences, Tabriz, Iran; 2Infectious Disease and Tropical Medicine Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; 3Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: The rising worldwide incidence of tuberculosis (TB increases the demand for knowledge about its potential seroreactivity with other microbial agents. A few reports and the authors’ experiences indicate that tuberculosis may result in a false-positive brucellosis serology. This may cause a diagnostic challenge because of the close clinical resemblance of these two infections.Objective: The aim of the present prevalence study was to elucidate brucellosis seroreactivity in patients with active TB.Methods: Ninety-eight patients with newly diagnosed and active TB were studied using an enzyme-linked immunosorbent assay (ELISA and Wright’s and Coombs–Wright’s tests. Seventy-five healthy individuals were used as controls. The patients showed signs of recovery after starting a standard anti-TB regimen and had no clinical evidence of brucellosis at a subsequent 6-month follow-up. The data were analyzed statistically by Fisher’s exact test using SPSS 11.0.Results: We found that 9.2% of TB patients versus 1.3% of healthy controls had positive results on the anti-Brucella IgG ELISA (P = 0.04. Five TB patients were found to have agglutination on Wright’s tests, while none of the controls showed agglutination.Conclusion: Active TB patients may have some seroreactivity with Brucella antigens, and Brucella IgG ELISA may give a false positive in these patients. Clinicians should consider false positive brucellosis seroreactivity in patients with active TB.Keywords: false positive serology, ELISA, diagnosis

  20. False-positive results in pharmacoepidemiology and pharmacovigilance.

    Science.gov (United States)

    Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine

    2017-09-01

    False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  1. Magnetic resonance imaging of lumbar spine disc diseases. Frequency of false negatives

    International Nuclear Information System (INIS)

    Berthelot, J.M.; Maugars, Y.; Delecrin, Y.; Caillon, F.; Prost, A.

    1995-01-01

    Magnetic resonance imaging (MRI) has had an impressive impact on evaluation of degenerative diseases of the spine. Nevertheless, false negatives can occur on images involving lumbar discs. Degenerative disc diseases documented on discography and/or pathology examination of the discs can go unrecognized. Likewise sensitivity for the detection of protruding disc hernias is not totally satisfactory (20% false negatives). Finally, a magnetic resonance image visualizing displacement of the disc is not specific (10 to 15% false positives); images showing protrusion or hernia can be seen in 30% of asymptomatic patients. Although MRI gives slightly more information than other imaging techniques, false images do exist. Moreover, the usefulness of MRI to demonstrate disc disease in case of a negative CT-scan remains to be demonstrated. (authors). 26 refs

  2. False-positive 111In-pentetreotide Uptake in Gastritis

    International Nuclear Information System (INIS)

    Usmani, Sharjeel; Alshammari, Alshaima

    2013-01-01

    111 In-pentetreotide [ 111 In-octreoscan] is the most widely used radiolabeled somatostatin analog for evaluating neuroendocrine tumor overexpression of somatostatin receptors. False-positives studies of somatostatin receptor scintigraphy have been reported and often the cause is unexplained but assumed to be due to high number of somatostatin receptors in other pathologies. Causes of false-positives include visualization of the gallbladder, nasal mucosa and pulmonary hilar areas in respiratory infections, thyroid abnormalities, accessory spleens, recent Cerebrovascular accidents (CVA's) and activity at the site of a recent surgical incision. In infection or inflammation the cause of false-positive uptake is probably the result of tracer binding by somatostatin receptors on the inflammatory leukocytes. In this case report, we report, a 44-year-old male patient with false-positive 111 In-pentetreotide uptake due to gastritis

  3. An investigation of false positive dosimetry results

    International Nuclear Information System (INIS)

    Lewandowski, M.A.; Davis, S.A.; Goff, T.E.; Wu, C.F.

    1996-01-01

    The Waste Isolation Pilot Plant (WIPP) is a facility designed for the demonstration of the safe disposal of transuranic waste. Currently, the radiation source term is confined to sealed calibration and check sources since WIPP has not received waste for disposal. For several years the WIPP Dosimetry Group has operated a Harshaw Model 8800C reader to analyze Harshaw 8801-7776 thermoluminescent cards (3 TLD-700 and 1 TLD-600) with 8805 holder. The frequency of false positive results for quarterly dosimeter exchanges is higher than desired by the Dosimetry Group management. Initial observations suggested that exposure to intense ambient sunlight may be responsible for the majority of the false positive readings for element 3. A study was designed to investigate the possibility of light leaking through the holder and inducing a signal in element 3. This paper discusses the methods and results obtained, with special emphasis placed on recommendations to reduce the frequency of light-induced false positive readings

  4. Characterisation of false-positive observations in botanical surveys

    Directory of Open Access Journals (Sweden)

    Quentin J. Groom

    2017-05-01

    Full Text Available Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify

  5. False-negative diffusion-weighted imaging findings in acute stroke

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Yuasa, Naoki; Otomo, Takashi; Shiramizu, Hideki; Matsuda, Hiroshi; Kitagawa, Yasuhisa; Takagi, Shigeharu

    2006-01-01

    The utility of DWI (diffusion-weighted imaging) has been established in acute ischemic stroke. However, some patients with acute stroke show no abnormal signals on DWI, despite the presence of infarction (false-negative DWI). We analyzed the relationship between false-negative DWI and the clinical manifestations of acute ischemic stroke in 151 DWI-positive (89%) and 19 false-negative DWI (11%) patients. We performed MRI within 24 hours after onset at our hospital. Non-specific clinical manifestations, including vertigo and nausea, were frequently observed in false-negative DWI patients. As regards the vascular territory, false-negative DWI was noted in 15.3% of 59 patients with infarctions within the territory of the vertebrobasilar artery. Concerning the duration from onset to initial imaging, 73.7% of the patients with false-negative DWI findings underwent MRI examination within 6 hours after onset. Of the patients with false-negative DWI, 84.2% had lacunar infarction (χ 2 =16.4, P<0.001). In conclusion, false negative DWI is more frequently observed in lacunar infarction than in atherothrombotic infarction or cardiogenic embolism. It is important to examine carefully the neurological changes occurring in patients who present with acute stroke, but have negative DWI findings. (author)

  6. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  7. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  8. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  9. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  10. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  11. Performance quantification of clustering algorithms for false positive removal in fMRI by ROC curves

    Directory of Open Access Journals (Sweden)

    André Salles Cunha Peres

    Full Text Available Abstract Introduction Functional magnetic resonance imaging (fMRI is a non-invasive technique that allows the detection of specific cerebral functions in humans based on hemodynamic changes. The contrast changes are about 5%, making visual inspection impossible. Thus, statistic strategies are applied to infer which brain region is engaged in a task. However, the traditional methods like general linear model and cross-correlation utilize voxel-wise calculation, introducing a lot of false-positive data. So, in this work we tested post-processing cluster algorithms to diminish the false-positives. Methods In this study, three clustering algorithms (the hierarchical cluster, k-means and self-organizing maps were tested and compared for false-positive removal in the post-processing of cross-correlation analyses. Results Our results showed that the hierarchical cluster presented the best performance to remove the false positives in fMRI, being 2.3 times more accurate than k-means, and 1.9 times more accurate than self-organizing maps. Conclusion The hierarchical cluster presented the best performance in false-positive removal because it uses the inconsistency coefficient threshold, while k-means and self-organizing maps utilize a priori cluster number (centroids and neurons number; thus, the hierarchical cluster avoids clustering scattered voxels, as the inconsistency coefficient threshold allows only the voxels to be clustered that are at a minimum distance to some cluster.

  12. New false color mapping for image fusion

    NARCIS (Netherlands)

    Toet, A.; Walraven, J.

    1996-01-01

    A pixel based colour mapping algorithm is presented that produces a fused false colour rendering of two gray level images representing different sensor modalities. The result-ing fused false colour images have a higher information content than each of the original images and retain sensor-specific

  13. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Directory of Open Access Journals (Sweden)

    Yamaguchi Rin

    2012-05-01

    Full Text Available Abstract Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases, to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6% cases were benign, including mastopathy (fibrocystic disease in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9% cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC being significantly more frequent (49.5% than papillotubular growing type (Papi-tub (P P = 0.0001 and ductal carcinoma in situ (DCIS (P = 0.0001. Among 458 indeterminate cases, 54/139 (38.8% were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0% and 73/139 (52.5% were malignant, with SIDC being the most frequent malignant tumor (37.0%. Among 52 false-negative cases, SIDC was significantly more frequent (42.3% than DCIS (P = 0.0049 and Papi-tub (P = 0.001. There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for

  14. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  15. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  16. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    Energy Technology Data Exchange (ETDEWEB)

    Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp [Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi 470-1192 (Japan); Fujita, Hiroshi [Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University, 1-1 Yanagido, Gifu 501-1194 (Japan); Yamamuro, Osamu; Tamaki, Tsuneo [East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi 464-0044 (Japan)

    2016-06-15

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  17. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    International Nuclear Information System (INIS)

    Teramoto, Atsushi; Fujita, Hiroshi; Yamamuro, Osamu; Tamaki, Tsuneo

    2016-01-01

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  18. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  19. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Science.gov (United States)

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  20. Addressing False Positives in Early Reading Assessment Using Intervention Response Data

    Science.gov (United States)

    McAlenney, Athena Lentini; Coyne, Michael D.

    2015-01-01

    The current study examined a solution to high false positive reading risk classification rates in early kindergarten by investigating a method of identifying students with possible false positive risk classifications and returning them to general classroom instruction. Researchers assessed kindergarten students (N = 105) identified as at risk who…

  1. Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model

    International Nuclear Information System (INIS)

    Ayres, Fabio J.; Rangayyan, Rangaraj M.

    2007-01-01

    Objective One of the commonly missed signs of breast cancer is architectural distortion. We have developed techniques for the detection of architectural distortion in mammograms, based on the analysis of oriented texture through the application of Gabor filters and a linear phase portrait model. In this paper, we propose constraining the shape of the general phase portrait model as a means to reduce the false-positive rate in the detection of architectural distortion. Material and methods The methods were tested with one set of 19 cases of architectural distortion and 41 normal mammograms, and with another set of 37 cases of architectural distortion. Results Sensitivity rates of 84% with 4.5 false positives per image and 81% with 10 false positives per image were obtained for the two sets of images. Conclusion The adoption of a constrained phase portrait model with a symmetric matrix and the incorporation of its condition number in the analysis resulted in a reduction in the false-positive rate in the detection of architectural distortion. The proposed techniques, dedicated for the detection and localization of architectural distortion, should lead to efficient detection of early signs of breast cancer. (orig.)

  2. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  3. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    International Nuclear Information System (INIS)

    Poortman, Pieter; Lohle, Paul N.M.; Schoemaker, Cees M.; Cuesta, Miguel A.; Oostvogel, Henk J.M.; Lange-de Klerk, Elly S.M. de; Hamming, Jaap F.

    2010-01-01

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  4. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  5. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    Science.gov (United States)

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  6. Risk of breast cancer after false-positive results in mammographic screening

    DEFF Research Database (Denmark)

    Roman, Marta; Castells, Xavier; Hofvind, Solveig

    2016-01-01

    risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50–69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1......Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level.......4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93–2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77–1.96), whereas those who tested false-positive at third screening had a RR...

  7. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  8. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  9. Risk of breast cancer after false-positive results in mammographic screening.

    Science.gov (United States)

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  10. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  11. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    NARCIS (Netherlands)

    Wolf, M.; Kurvers, R.H.J.M.; Ward, A.J.W.; Krause, S.; Krause, J.

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives;

  12. Positive events protect children from causal false memories for scripted events.

    Science.gov (United States)

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  13. False-positive uptake on 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) in oncological imaging

    International Nuclear Information System (INIS)

    Culverwell, A.D.; Scarsbrook, A.F.; Chowdhury, F.U.

    2011-01-01

    With the increasing utilization of integrated positron-emission tomography/computed tomography (PET/CT) using the glucose analogue 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) in oncological imaging, it is important for radiologists and nuclear medicine physicians to be aware that FDG uptake is not specific for malignancy, as many different physiological variants and benign pathological conditions can also exhibit increased glucose metabolism. Such false-positive FDG uptake often arises outside the area of primary interest and may mimic malignant disease, thereby confounding accurate interpretation of PET/CT studies. With the use of illustrative clinical cases, this article will provide a systematic overview of potential interpretative pitfalls and illustrate how such unexpected findings can be appropriately evaluated.

  14. Detecting false positive sequence homology: a machine learning approach.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  15. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    Science.gov (United States)

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  17. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  18. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  19. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  20. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    Science.gov (United States)

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  1. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    Science.gov (United States)

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  2. PRE-SPECTROSCOPIC FALSE-POSITIVE ELIMINATION OF KEPLER PLANET CANDIDATES

    International Nuclear Information System (INIS)

    Batalha, Natalie M.; Rowe, Jason F.; Borucki, William J.; Koch, David G.; Lissauer, Jack J.; Gilliland, Ronald L.; Jenkins, Jon J.; Caldwell, Douglas; Dunham, Edward W.; Gautier, Thomas N.; Howell, Steve B.; Latham, David W.; Marcy, Geoff W.; Prsa, Andrej

    2010-01-01

    Ten days of commissioning data (Quarter 0) and 33 days of science data (Quarter 1) yield instrumental flux time series of ∼150,000 stars that were combed for transit events, termed threshold crossing events(TCE), each having a total detection statistic above 7.1σ. TCE light curves are modeled as star+planet systems. Those returning a companion radius smaller than 2R J are assigned a Kepler Object of Interest (KOI) number. The raw flux, pixel flux, and flux-weighted centroids of every KOI are scrutinized to assess the likelihood of being an astrophysical false positive versus the likelihood of being a planetary companion. This vetting using Kepler data is referred to as data validation (DV). Herein, we describe the DV metrics and graphics used to identify viable planet candidates amongst the KOIs. Light curve modeling tests for (1) the difference in depth of the odd- versus even-numbered transits, (2) evidence of ellipsoidal variations, and (3) evidence of a secondary eclipse event at phase = 0.5. Flux-weighted centroids are used to test for signals correlated with transit events with a magnitude and direction indicative of a background eclipsing binary. Centroid time series are complimented by analysis of images taken in-transit versus out-of-transit, the difference often revealing the pixel contributing the most to the flux change during transit. Examples are shown to illustrate each test. Candidates passing DV are submitted to ground-based observers for further false-positive elimination or confirmation/characterization.

  3. Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Armato, Samuel G. III; Li, Feng; Sone, Shusuke; Doi, Kunio

    2003-01-01

    In this study, we investigated a pattern-recognition technique based on an artificial neural network (ANN), which is called a massive training artificial neural network (MTANN), for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography (CT) images. The MTANN consists of a modified multilayer ANN, which is capable of operating on image data directly. The MTANN is trained by use of a large number of subregions extracted from input images together with the teacher images containing the distribution for the 'likelihood of being a nodule'. The output image is obtained by scanning an input image with the MTANN. The distinction between a nodule and a non-nodule is made by use of a score which is defined from the output image of the trained MTANN. In order to eliminate various types of non-nodules, we extended the capability of a single MTANN, and developed a multiple MTANN (Multi-MTANN). The Multi-MTANN consists of plural MTANNs that are arranged in parallel. Each MTANN is trained by using the same nodules, but with a different type of non-nodule. Each MTANN acts as an expert for a specific type of non-nodule, e.g., five different MTANNs were trained to distinguish nodules from various-sized vessels; four other MTANNs were applied to eliminate some other opacities. The outputs of the MTANNs were combined by using the logical AND operation such that each of the trained MTANNs eliminated none of the nodules, but removed the specific type of non-nodule with which the MTANN was trained, and thus removed various types of non-nodules. The Multi-MTANN consisting of nine MTANNs was trained with 10 typical nodules and 10 non-nodules representing each of nine different non-nodule types (90 training non-nodules overall) in a training set. The trained Multi-MTANN was applied to the reduction of false positives reported by our current computerized scheme for lung nodule detection based on a database of 63 low-dose CT scans (1765

  4. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  5. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  6. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  7. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  8. In-111-labeled leukocyte imaging: false-positive study due to acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Fisher, M.F.; Rudd, T.G.

    1983-01-01

    A case is reported in which In-111-labeled leukocytes accumulated in the left colon on a 24-hr delayed image. This was found to be secondary to an upper gastrointestinal bleed in progress at the time of injection of the radiolabeled leukocytes

  9. Psychological effects of false-positive results in expanded newborn screening in China.

    Directory of Open Access Journals (Sweden)

    Wen-Jun Tu

    Full Text Available OBJECTIVES: As more families participate expanded newborn screening for metabolic disorders in China, the overall number of false positives increases. Our goal was to assess the potential impact on parental stress, perceptions of the child's health, and family relationships. METHODS: Parents of 49 infants with false-positive screening results for metabolic disorders in the expanded newborn screening panel were compared with parents of 42 children with normal screening results. Parents first completed structured interview using likert scales, closed and open questions. Parents also completed the parenting stress index. RESULTS: A total of 88 mothers and 41 fathers were interviewed. More mothers in the false-positive group reported that their children required extra parental care (21%, compared with 5% of mothers in the normal-screened group (P<0.001. 39% of mothers in the false-positive group reported that they worry about their child's future development, compared with 10% of mothers in the normal-screened group (P<0.001. Fathers in the false-positive group did not differ from fathers in the normal-screened group in reporting worry about their child's extra care requirements, and their child's future development. Children with false-positive results compared with children with normal results were triple as likely to experience hospitalization (27%vs 9%, respectively; P<0.001. CONCLUSIONS: The results showing false-positive screening results may affect parental stress and the parent-child relationship. Parental stress and anxiety can be reduced with improved education and communication to parents about false-positive results.

  10. Relapse surveillance in AFP-positive hepatoblastoma: re-evaluating the role of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rojas, Yesenia; Vasudevan, Sanjeev A.; Nuchtern, Jed G. [Baylor College of Medicine, Pediatric Surgery Division, Michael E. DeBakey Department of Surgery, Texas Children' s Hospital, Houston, TX (United States); Guillerman, R.P. [Baylor College of Medicine, Department of Pediatric Radiology, Texas Children' s Hospital, Houston, TX (United States); Zhang, Wei [Texas Children' s Hospital, Surgical Outcomes Center, Houston, TX (United States); Thompson, Patrick A. [Baylor College of Medicine, Hematology-Oncology Division, Department of Pediatrics, Texas Children' s Cancer Center, Texas Children' s Hospital, Houston, TX (United States); University of North Carolina, Hematology-Oncology Division, Department of Pediatrics, North Carolina Children' s Hospital, Chapel Hill, NC (United States)

    2014-10-15

    Children with hepatoblastoma routinely undergo repetitive surveillance imaging, with CT scans for several years after therapy, increasing the risk of radiation-induced cancer. The purpose of this study was to determine the utility of surveillance CT scans compared to serum alpha-fetoprotein (AFP) levels for the detection of hepatoblastoma relapse. This was a retrospective study of all children diagnosed with AFP-positive hepatoblastoma from 2001 to 2011 at a single institution. Twenty-six children with hepatoblastoma were identified, with a mean age at diagnosis of 2 years 4 months (range 3 months to 11 years). Mean AFP level at diagnosis was 132,732 ng/ml (range 172.8-572,613 ng/ml). Five of the 26 children had hepatoblastoma relapse. A total of 105 imaging exams were performed following completion of therapy; 88 (84%) CT, 8 (8%) MRI, 5 (5%) US and 4 (4%) FDG PET/CT exams. A total of 288 alpha-fetoprotein levels were drawn, with a mean of 11 per child. The AFP level was elevated in all recurrences and no relapses were detected by imaging before AFP elevation. Two false-positive AFP levels and 15 false-positive imaging exams were detected. AFP elevation was found to be significantly more specific than PET/CT and CT imaging at detecting relapse. We recommend using serial serum AFP levels as the preferred method of surveillance in children with AFP-positive hepatoblastoma, reserving imaging for the early postoperative period, for children at high risk of relapse, and for determination of the anatomical site of clinically suspected recurrence. Given the small size of this preliminary study, validation in a larger patient population is warranted. (orig.)

  11. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  12. Epidemiology, public health, and the rhetoric of false positives

    DEFF Research Database (Denmark)

    Blair, Aaron; Saracci, Rodolfo; Vineis, Paolo

    2009-01-01

    BACKGROUND: As an observational science, epidemiology is regarded by some researchers as inherently flawed and open to false results. In a recent paper, Boffetta et al. [Boffetta P, McLaughlin JK, LaVecchia C, Tarone RE, Lipworth L, Blot WJ. False-positive results in cancer epidemiology: a plea f...

  13. Analyzing false positives of four questions in the Force Concept Inventory

    Science.gov (United States)

    Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-06-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.

  14. False positive reduction in protein-protein interaction predictions using gene ontology annotations

    Directory of Open Access Journals (Sweden)

    Lin Yen-Han

    2007-07-01

    Full Text Available Abstract Background Many crucial cellular operations such as metabolism, signalling, and regulations are based on protein-protein interactions. However, the lack of robust protein-protein interaction information is a challenge. One reason for the lack of solid protein-protein interaction information is poor agreement between experimental findings and computational sets that, in turn, comes from huge false positive predictions in computational approaches. Reduction of false positive predictions and enhancing true positive fraction of computationally predicted protein-protein interaction datasets based on highly confident experimental results has not been adequately investigated. Results Gene Ontology (GO annotations were used to reduce false positive protein-protein interactions (PPI pairs resulting from computational predictions. Using experimentally obtained PPI pairs as a training dataset, eight top-ranking keywords were extracted from GO molecular function annotations. The sensitivity of these keywords is 64.21% in the yeast experimental dataset and 80.83% in the worm experimental dataset. The specificities, a measure of recovery power, of these keywords applied to four predicted PPI datasets for each studied organisms, are 48.32% and 46.49% (by average of four datasets in yeast and worm, respectively. Based on eight top-ranking keywords and co-localization of interacting proteins a set of two knowledge rules were deduced and applied to remove false positive protein pairs. The 'strength', a measure of improvement provided by the rules was defined based on the signal-to-noise ratio and implemented to measure the applicability of knowledge rules applying to the predicted PPI datasets. Depending on the employed PPI-predicting methods, the strength varies between two and ten-fold of randomly removing protein pairs from the datasets. Conclusion Gene Ontology annotations along with the deduced knowledge rules could be implemented to partially

  15. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  16. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  17. Evaluation of false positivity and cross reactivity in the investigation ...

    African Journals Online (AJOL)

    This study evaluated the causes of false positive Human Immunodeficiency Virus test results (F+HIV), cross reactivity of HIV antibodies with other non HIV antibodies, and efficiency of the serial and parallel testing algorithms. 100 blood samples randomly collected from clients attending the Heart to Heart HIV counseling and ...

  18. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  19. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  20. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  1. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  2. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  3. Look Again: An Investigation of False Positive Detections in Combat Models

    National Research Council Canada - National Science Library

    Wainwright, Ryan K

    2008-01-01

    .... Existing combat models tend to overlook or downplay false positive detections. Signal Detection Theory provides the framework for analysis of an observer's hits, misses, correct rejections, and false alarms...

  4. Destroying False Images of God: The Experiences of LGBT Catholics.

    Science.gov (United States)

    Deguara, Angele

    2018-01-01

    This article is about how lesbian, gay, bisexual, and trans (LGBT) Catholics imagine God and how images of God change in parallel with their self-image. The study is based on qualitative research with LGBT Catholics, most of whom are members of Drachma LGBTI in Malta or Ali d'Aquila in Palermo, Sicily. LGBT Catholics' image of God changes as they struggle to reconcile their religious and sexual identities and as they go through a process of "conversion" from deviants and sinners to loved children of God. One study participant compares his faith in God to peeling an onion: "With every layer one peels off, one destroys false images of God." Most study participants have moved away from the image of God as a bearded old man and father of creation and moved more toward a conception of God as love once identity conflicts are resolved.

  5. ST-Segment Depression in Hyperventilation Indicates a False Positive Exercise Test in Patients with Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Andreas P. Michaelides

    2010-01-01

    Full Text Available Objectives. Mitral valve prolapse (MVP is a known cause for false positive exercise test (ET. The purpose of this study was to establish additional electrocardiographic criteria to distinguish the false positive exercise results in patients with MVP. Methods. We studied 218 consecutive patients ( years, 103 males with MVP (according to echocardiographic study, and positive treadmill ET was performed due to multiple cardiovascular risk factors or angina-like symptoms. A coronary angiography was performed to detect coronary artery disease (CAD. Results. From 218 patients, 90 (group A presented with normal coronary arteries according to the angiography (false positive ET while the rest 128 (group B presented with CAD. ST-segment depression in hyperventilation phase was present in 54 patients of group A (60% while only in 14 patients of group B (11%, . Conclusions. Presence of ST-segment depression in hyperventilation phase favors a false positive ET in patients with MVP.

  6. Categorizing Mistaken False Positives in Regulation of Human and Environmental Health

    DEFF Research Database (Denmark)

    Hansen, Steffen Foss; Krayer von Krauss, Martin Paul; Tickner, J.A.

    2007-01-01

    One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general......," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only...... four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent...

  7. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  8. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  9. Proteins interacting with cloning scars: a source of false positive protein-protein interactions.

    Science.gov (United States)

    Banks, Charles A S; Boanca, Gina; Lee, Zachary T; Florens, Laurence; Washburn, Michael P

    2015-02-23

    A common approach for exploring the interactome, the network of protein-protein interactions in cells, uses a commercially available ORF library to express affinity tagged bait proteins; these can be expressed in cells and endogenous cellular proteins that copurify with the bait can be identified as putative interacting proteins using mass spectrometry. Control experiments can be used to limit false-positive results, but in many cases, there are still a surprising number of prey proteins that appear to copurify specifically with the bait. Here, we have identified one source of false-positive interactions in such studies. We have found that a combination of: 1) the variable sequence of the C-terminus of the bait with 2) a C-terminal valine "cloning scar" present in a commercially available ORF library, can in some cases create a peptide motif that results in the aberrant co-purification of endogenous cellular proteins. Control experiments may not identify false positives resulting from such artificial motifs, as aberrant binding depends on sequences that vary from one bait to another. It is possible that such cryptic protein binding might occur in other systems using affinity tagged proteins; this study highlights the importance of conducting careful follow-up studies where novel protein-protein interactions are suspected.

  10. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Limited agreement of independent RNAi screens for virus-required host genes owes more to false-negative than false-positive factors.

    Directory of Open Access Journals (Sweden)

    Linhui Hao

    Full Text Available Systematic, genome-wide RNA interference (RNAi analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%. However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis.

  12. THE XO PLANETARY SURVEY PROJECT: ASTROPHYSICAL FALSE POSITIVES

    International Nuclear Information System (INIS)

    Poleski, Radosaw; McCullough, Peter R.; Valenti, Jeff A.; Burke, Christopher J.; Machalek, Pavel; Janes, Kenneth

    2010-01-01

    Searches for planetary transits find many astrophysical false positives as a by-product. There are four main types analyzed in the literature: a grazing-incidence eclipsing binary (EB) star, an EB star with a small radius companion star, a blend of one or more stars with an unrelated EB star, and a physical triple star system. We present a list of 69 astrophysical false positives that had been identified as candidates of transiting planets of the on-going XO survey. This list may be useful in order to avoid redundant observation and characterization of these particular candidates that have been independently identified by other wide-field searches for transiting planets. The list may be useful for those modeling the yield of the XO survey and surveys similar to it. Subsequent observations of some of the listed stars may improve mass-radius relations, especially for low-mass stars. From the candidates exhibiting eclipses, we report three new spectroscopic double-line binaries and give mass function estimations for 15 single-line spectroscopic binaries.

  13. False memory and level of processing effect: an event-related potential study.

    Science.gov (United States)

    Beato, Maria Soledad; Boldini, Angela; Cadavid, Sara

    2012-09-12

    Event-related potentials (ERPs) were used to determine the effects of level of processing on true and false memory, using the Deese-Roediger-McDermott (DRM) paradigm. In the DRM paradigm, lists of words highly associated to a single nonpresented word (the 'critical lure') are studied and, in a subsequent memory test, critical lures are often falsely remembered. Lists with three critical lures per list were auditorily presented here to participants who studied them with either a shallow (saying whether the word contained the letter 'o') or a deep (creating a mental image of the word) processing task. Visual presentation modality was used on a final recognition test. True recognition of studied words was significantly higher after deep encoding, whereas false recognition of nonpresented critical lures was similar in both experimental groups. At the ERP level, true and false recognition showed similar patterns: no FN400 effect was found, whereas comparable left parietal and late right frontal old/new effects were found for true and false recognition in both experimental conditions. Items studied under shallow encoding conditions elicited more positive ERP than items studied under deep encoding conditions at a 1000-1500 ms interval. These ERP results suggest that true and false recognition share some common underlying processes. Differential effects of level of processing on true and false memory were found only at the behavioral level but not at the ERP level.

  14. Magnetic resonance imaging of lumbar spine disc diseases. Frequency of false negatives; Imagerie par resonance magnetique pour pathologie discale lombaire. Frequence des faux-negatifs

    Energy Technology Data Exchange (ETDEWEB)

    Berthelot, J.M.; Maugars, Y.; Delecrin, Y.; Caillon, F.; Prost, A. [Hopital Hotel-Dieu de Nantes, 44 (France)

    1995-10-01

    Magnetic resonance imaging (MRI) has had an impressive impact on evaluation of degenerative diseases of the spine. Nevertheless, false negatives can occur on images involving lumbar discs. Degenerative disc diseases documented on discography and/or pathology examination of the discs can go unrecognized. Likewise sensitivity for the detection of protruding disc hernias is not totally satisfactory (20% false negatives). Finally, a magnetic resonance image visualizing displacement of the disc is not specific (10 to 15% false positives); images showing protrusion or hernia can be seen in 30% of asymptomatic patients. Although MRI gives slightly more information than other imaging techniques, false images do exist. Moreover, the usefulness of MRI to demonstrate disc disease in case of a negative CT-scan remains to be demonstrated. (authors). 26 refs.

  15. The uterine blush. A potential false-positive in Meckel's scan interpretation

    International Nuclear Information System (INIS)

    Fink-Bennett, D.

    1982-01-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations

  16. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    Science.gov (United States)

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  17. Memory for media: investigation of false memories for negatively and positively charged public events.

    Science.gov (United States)

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  18. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  19. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  20. Algorithm of reducing the false positives in IDS based on correlation Analysis

    Science.gov (United States)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  1. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  2. Newly formed skeletal muscle fibers are prone to false positive immunostaining by rabbit antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Kliem, Anette; Schrøder, Henrik Daa

    2011-01-01

    rely on controls that reveal non-specific binding by the secondary antibody and neglect that the primary rabbit antibody itself may cause false positive staining of the muscle. We suggest that reliable immuno-based protein detection in newly formed muscle fibers at least requires a nonsense rabbit......Reports on muscle biology and regeneration often implicate immuno(cyto/histo)chemical protein characterization using rabbit polyclonal antibodies. In this study we demonstrate that newly formed myofibers are especially prone to false positive staining by rabbit antibodies and this unwanted staining...

  3. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    Science.gov (United States)

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  4. APHRODITE: an Anomaly-based Architecture for False Positive Reduction

    NARCIS (Netherlands)

    Bolzoni, D.; Etalle, Sandro

    We present APHRODITE, an architecture designed to reduce false positives in network intrusion detection systems. APHRODITE works by detecting anomalies in the output traffic, and by correlating them with the alerts raised by the NIDS working on the input traffic. Benchmarks show a substantial

  5. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis

    DEFF Research Database (Denmark)

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian

    2016-01-01

    outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction...... of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each...... new trial. For each false positive, we performed TSA, using three different approaches. RESULTS: We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta...

  6. Multi-scale textural feature extraction and particle swarm optimization based model selection for false positive reduction in mammography.

    Science.gov (United States)

    Zyout, Imad; Czajkowska, Joanna; Grzegorzek, Marcin

    2015-12-01

    The high number of false positives and the resulting number of avoidable breast biopsies are the major problems faced by current mammography Computer Aided Detection (CAD) systems. False positive reduction is not only a requirement for mass but also for calcification CAD systems which are currently deployed for clinical use. This paper tackles two problems related to reducing the number of false positives in the detection of all lesions and masses, respectively. Firstly, textural patterns of breast tissue have been analyzed using several multi-scale textural descriptors based on wavelet and gray level co-occurrence matrix. The second problem addressed in this paper is the parameter selection and performance optimization. For this, we adopt a model selection procedure based on Particle Swarm Optimization (PSO) for selecting the most discriminative textural features and for strengthening the generalization capacity of the supervised learning stage based on a Support Vector Machine (SVM) classifier. For evaluating the proposed methods, two sets of suspicious mammogram regions have been used. The first one, obtained from Digital Database for Screening Mammography (DDSM), contains 1494 regions (1000 normal and 494 abnormal samples). The second set of suspicious regions was obtained from database of Mammographic Image Analysis Society (mini-MIAS) and contains 315 (207 normal and 108 abnormal) samples. Results from both datasets demonstrate the efficiency of using PSO based model selection for optimizing both classifier hyper-parameters and parameters, respectively. Furthermore, the obtained results indicate the promising performance of the proposed textural features and more specifically, those based on co-occurrence matrix of wavelet image representation technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. A FALSE POSITIVE FOR OCEAN GLINT ON EXOPLANETS: THE LATITUDE-ALBEDO EFFECT

    International Nuclear Information System (INIS)

    Cowan, Nicolas B.; Abbot, Dorian S.; Voigt, Aiko

    2012-01-01

    Identifying liquid water on the surface of planets is a high priority, as this traditionally defines habitability. One proposed signature of oceans is specular reflection ('glint'), which increases the apparent albedo of a planet at crescent phases. We post-process a global climate model of an Earth-like planet to simulate reflected light curves. Significantly, we obtain glint-like phase variations even though we do not include specular reflection in our model. This false positive is the product of two generic properties: (1) for modest obliquities, a planet's poles receive less orbit-averaged stellar flux than its equator, so the poles are more likely to be covered in highly reflective snow and ice; and (2) we show that reflected light from a modest-obliquity planet at crescent phases probes higher latitudes than at gibbous phases, therefore a planet's apparent albedo will naturally increase at crescent phase. We suggest that this 'latitude-albedo effect' will operate even for large obliquities: in that case the equator receives less orbit-averaged flux than the poles, and the equator is preferentially sampled at crescent phase. Using rotational and orbital color variations to map the surfaces of directly imaged planets and estimate their obliquity will therefore be a necessary pre-condition for properly interpreting their reflected phase variations. The latitude-albedo effect is a particularly convincing glint false positive for zero-obliquity planets, and such worlds are not amenable to latitudinal mapping. This effect severely limits the utility of specular reflection for detecting oceans on exoplanets.

  8. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    International Nuclear Information System (INIS)

    Zubizarreta Alberdi, Raquel; Llanes, Ana B.F.; Ortega, Raquel Almazan; Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells; Queiro Verdes, Teresa; Natal Ramos, Carmen; Sanz, Maria Ederra; Salas Trejo, Dolores

    2011-01-01

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p 14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  9. Parental knowledge reduces long term anxiety induced by false-positive test results after newborn screening for cystic fibrosis

    NARCIS (Netherlands)

    Vernooij-van Langen, A.M.M.; Pal, S.M. van der; Reijntjens, A.J.T.; Loeber, J.G.; Dompeling, E.; Dankert-Roelse, J.E.

    2014-01-01

    Background: False-positive screening results in newborn screening for cystic fibrosis may lead to parental stress, family relationship problems and a changed perception of the child's health. Aim of the study: To evaluate whether parental anxiety induced by a false positive screening result

  10. Future directions for positive body image research.

    Science.gov (United States)

    Halliwell, Emma

    2015-06-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for future positive body image research are outlined: (a) conceptualization, (b) models, (c) developmental factors, (d) social interactions, (e) cognitive processing style, and (f) interventions. Finally, the potential role of positive body image as a protective factor within the broader body image literature is discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    Science.gov (United States)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  12. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  13. Waiting time and the psychosocial consequences of false-positive mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert; Brodersen, John

    2015-01-01

    Background: There is wide variation in the psychosocial response to false-positive mammography. We aimed to assess whether women having to wait longer to exclude cancer had increased psychosocial consequences that persisted after cancer was ruled out. Findings: We selected women with false......-positive mammography (n = 272), screened for breast cancer in Copenhagen and Funen (Denmark) over a 1-year period. We measured psychosocial consequences immediately before women attended their recall visit and 1, 6, 18 and 36 months after women received their final diagnosis. After women were told that cancer had been...... ruled out, adverse psychosocial consequences decreased with time. We found no statistically significant differences between women who had cancer ruled out immediately at the recall visit (waiting time of 0) and women who had to wait longer before cancer was ruled out (waiting times 1-30, 30...

  14. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    Science.gov (United States)

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  15. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  16. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    Science.gov (United States)

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  17. Future directions for positive body image research

    OpenAIRE

    Halliwell, E.

    2015-01-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for fu...

  18. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  19. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  20. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  1. The OGCleaner: filtering false-positive homology clusters.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Snell, Quinn; Bybee, Seth M

    2017-01-01

    Detecting homologous sequences in organisms is an essential step in protein structure and function prediction, gene annotation and phylogenetic tree construction. Heuristic methods are often employed for quality control of putative homology clusters. These heuristics, however, usually only apply to pairwise sequence comparison and do not examine clusters as a whole. We present the Orthology Group Cleaner (the OGCleaner), a tool designed for filtering putative orthology groups as homology or non-homology clusters by considering all sequences in a cluster. The OGCleaner relies on high-quality orthologous groups identified in OrthoDB to train machine learning algorithms that are able to distinguish between true-positive and false-positive homology groups. This package aims to improve the quality of phylogenetic tree construction especially in instances of lower-quality transcriptome assemblies. https://github.com/byucsl/ogcleaner CONTACT: sfujimoto@gmail.comSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. A Demonstration of Regression False Positive Selection in Data Mining

    Science.gov (United States)

    Pinder, Jonathan P.

    2014-01-01

    Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…

  3. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  4. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    Energy Technology Data Exchange (ETDEWEB)

    Zubizarreta Alberdi, Raquel [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Edificio Administrativo da Conselleria de Sanidade, Servicio de Programas Poboacionais de Cribado, Direccion Xeral de Saude Publica e Planificacion, Santiago de Compostela, Galicia (Spain); Llanes, Ana B.F.; Ortega, Raquel Almazan [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells [Department of Epidemiology and Evaluation, Institut Municipal d' Investigacio Medica-Parc de Salut Mar. CIBERESP, Barcelona (Spain); Queiro Verdes, Teresa [Galician Agency for Health Technology Assessment, Public Health and Planning Directorate, Health Office, Galicia (Spain); Natal Ramos, Carmen [Principality of Asturias Breast Cancer Screening Programme, Principality of Asturias (Spain); Sanz, Maria Ederra [Public Health Institute, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Salas Trejo, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia Breast Cancer Screening Programme, Valencia (Spain)

    2011-10-15

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p < 0.001) with greater reading volume in the previous year: OR 0.77 and OR 0.78, respectively, for a reading volume 500-1,999 mammograms and OR 0.59 and OR 0.60 for a reading volume of >14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  5. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  6. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    International Nuclear Information System (INIS)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.; Stuzman, R.E.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadal function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men

  7. False positive of the scintigraphy with octreoscan: a diagnosis of elimination; Faux positif de la scintigraphie a l'octreoscan: un diagnostic d'elimination

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, N.; Brenot-Rossi, I.; Chuto, G.; Giovannini, M.; Delpero, J.R. [Institut Paoli-Calmettes, Marseille, (France)

    2009-05-15

    The imaging of receptors with somatostatin analogs by the pentetreotide-indium 111 (octreoscan) allows the detection of endocrine tumors essentially according to the density of S.S.T.2 receptors at the tumor level. The sensitivity of octreoscan for the detection of intestine endocrine tumors is included between 80 and 100% in the different studies. The clinical case presented here enlightens a case of false positive.We concluded to a physiological elimination of pentetreotide-indium 111 with intra pancreatic biliary stasis (perhaps a dysfunction of sphincter of ampulla of bile duct) and to the lack of tumor centre. It is here a diagnosis of elimination, supported by the different results of examination. all normal. This case of false positive induced expensive and traumatic explorations for the patient. (N.C.)

  8. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  9. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  10. Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.

    Science.gov (United States)

    Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui

    2018-02-01

    Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Comparison of cumulative false-positive risk of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp

    2015-01-01

    INTRODUCTION: In the United States (US), about one-half of women screened with annual mammography have at least one false-positive test after ten screens. The estimate for European women screened ten times biennially is much lower. We evaluate to what extent screening interval, mammogram type......=400,204), between 1991-2012 and 1993-2013, respectively. Model-based cumulative false-positive risks were computed for the entire sample, using two statistical methods (Hubbard Njor) previously used to estimate false-positive risks in the US and Europe. RESULTS: Empirical cumulative risk of at least...... one false-positive test after eight (annual or biennial) screens was 41.9% in BCSC, 16.1% in Copenhagen, and 7.4% in Funen. Variation in screening interval and mammogram type did not explain the differences by country. Using the Hubbard method, the model-based cumulative risks after eight screens...

  12. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  13. The uterine blush. A potential false-positive in Meckel's scan interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fink-Bennett, D.

    1982-10-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.

  14. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  15. Data from Paper “False-Positive Psychology: Undisclosed Flexibility in Data Collection and Analysis Allows Presenting Anything as Significant”

    Directory of Open Access Journals (Sweden)

    Joseph P Simmons

    2014-02-01

    Full Text Available The data includes measures collected for the two experiments reported in “False-Positive Psychology” [1] where listening to a randomly assigned song made people feel younger (Study 1 or actually be younger (Study 2. These data are useful because they illustrate inflations of false positive rates due to flexibility in data collection, analysis, and reporting of results. Data are useful for educational purposes.

  16. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    Science.gov (United States)

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  20. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  1. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  2. Three-channel false colour AFM images for improved interpretation of complex surfaces: A study of filamentous cyanobacteria

    International Nuclear Information System (INIS)

    Kurk, Toby; Adams, David G.; Connell, Simon D.; Thomson, Neil H.

    2010-01-01

    Imaging signals derived from the atomic force microscope (AFM) are typically presented as separate adjacent images with greyscale or pseudo-colour palettes. We propose that information-rich false-colour composites are a useful means of presenting three-channel AFM image data. This method can aid the interpretation of complex surfaces and facilitate the perception of information that is convoluted across data channels. We illustrate this approach with images of filamentous cyanobacteria imaged in air and under aqueous buffer, using both deflection-modulation (contact) mode and amplitude-modulation (tapping) mode. Topography-dependent contrast in the error and tertiary signals aids the interpretation of the topography signal by contributing additional data, resulting in a more detailed image, and by showing variations in the probe-surface interaction. Moreover, topography-independent contrast and topography-dependent contrast in the tertiary data image (phase or friction) can be distinguished more easily as a consequence of the three dimensional colour-space.

  3. Three-channel false colour AFM images for improved interpretation of complex surfaces: A study of filamentous cyanobacteria

    Energy Technology Data Exchange (ETDEWEB)

    Kurk, Toby, E-mail: phytak@leeds.ac.uk [School of Physics and Astronomy, University of Leeds, Leeds, West Yorkshire LS2 9JT (United Kingdom); Adams, David G., E-mail: D.G.Adams@leeds.ac.uk [Faculty of Biological Sciences, University of Leeds, Leeds, West Yorkshire LS2 9JT (United Kingdom); Connell, Simon D., E-mail: S.D.A.Connell@leeds.ac.uk [School of Physics and Astronomy, University of Leeds, Leeds, West Yorkshire LS2 9JT (United Kingdom); Thomson, Neil H., E-mail: N.H.Thomson@leeds.ac.uk [School of Physics and Astronomy, University of Leeds, Leeds, West Yorkshire LS2 9JT (United Kingdom); Dental Institute, University of Leeds, Leeds, West Yorkshire LS2 9JT (United Kingdom)

    2010-05-15

    Imaging signals derived from the atomic force microscope (AFM) are typically presented as separate adjacent images with greyscale or pseudo-colour palettes. We propose that information-rich false-colour composites are a useful means of presenting three-channel AFM image data. This method can aid the interpretation of complex surfaces and facilitate the perception of information that is convoluted across data channels. We illustrate this approach with images of filamentous cyanobacteria imaged in air and under aqueous buffer, using both deflection-modulation (contact) mode and amplitude-modulation (tapping) mode. Topography-dependent contrast in the error and tertiary signals aids the interpretation of the topography signal by contributing additional data, resulting in a more detailed image, and by showing variations in the probe-surface interaction. Moreover, topography-independent contrast and topography-dependent contrast in the tertiary data image (phase or friction) can be distinguished more easily as a consequence of the three dimensional colour-space.

  4. False Positive Radioiodinated Metaiodobenzylguanidine (123I-MIBG Uptake in Undifferentiated Adrenal Malignant Tumor

    Directory of Open Access Journals (Sweden)

    Hee Soo Jung

    2015-01-01

    Full Text Available 123I-Metaiodobenzylguanidine (123I-MIBG scintigraphy is a widely used functional imaging tool with a high degree of sensitivity and specificity in diagnosis of pheochromocytoma. However, rare cases of false positive reactions have been reported. A 67-year-old male patient was admitted with epigastric pain. Abdominal computed tomography (CT revealed a heterogeneous left adrenal mass 6 cm in diameter; following hormone testing, 123I-MIBG scintigraphy was performed to determine the presence of pheochromocytoma, which confirmed eccentric uptake by a large left adrenal gland mass. Chest CT and PET-CT confirmed metastatic lymphadenopathy; therefore, endobronchial ultrasound transbronchial needle aspiration was performed. Metastatic carcinoma of unknown origin was suspected from a lymph node biopsy, and surgical resection was performed for definitive diagnosis and correction of excess hormonal secretion. A final diagnosis of undifferentiated adrenal malignant tumor was rendered, instead of histologically malignant pheochromocytoma, despite the uptake of 123I-MIBG demonstrated by scintigraphy.

  5. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    Science.gov (United States)

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  6. Suture Granuloma Showing False-Positive Findings on FDG-PET

    Directory of Open Access Journals (Sweden)

    Kohei Takahara

    2013-01-01

    Full Text Available We report a case of a 33-year-old male with a mixed germ-cell testicular tumor. Postoperative follow-up FDG-PET revealed concentration of FDG in the left inguinal area which is not tumor metastasis or local recurrence but suture reactivity granuloma. In this paper, we reviewed suture granulomas associated with false-positive findings on FDG-PET after surgery. If FDG-PET will be used more frequently in the future, it will be necessary to refrain from using silk thread in order to prevent any unnecessary surgery.

  7. Factors associated with false-positive self-reported adherence to antihypertensive drugs.

    Science.gov (United States)

    Tedla, Y G; Bautista, L E

    2017-05-01

    Self-reported medication adherence is known to overestimate true adherence. However, little is known about patient factors that may contribute to the upward bias in self-reported medication adherence. The objective of this study is to examine whether demographic, behavioral, medication and mood factors are associated with being a false-positive self-reported adherer (FPA) to antihypertensive drug treatment. We studied 175 patients (mean age: 50 years; 57% men) from primary-care clinics starting antihypertensive drug treatment. Self-reported adherence (SRA) was measured with the Medication Adherence Report Scale (MARS) and by the number of drug doses missed in the previous week/month, and compared with pill count adherence ratio (PCAR) as gold standard. Data on adherence, demographic, behavioral, medication and mood factors were collected at baseline and every 3 months up to 1 year. FPA was defined as being a non-adherer by PCAR and an adherer by self-report. Mixed effect logistic regression was used for the analysis. Twenty percent of participants were FPA. Anxiety increased (odds ratio (OR): 3.00; P=0.01), whereas smoking (OR: 0.40; P=0.03) and drug side effects (OR: 0.46, P=0.03) decreased the probability for FPA by MARS. Education below high-school completion increased the probability of being an FPA as measured by missing doses in the last month (OR: 1.66; P=0.04) and last week (OR: 1.88; P=0.02). The validity of SRA varies significantly according to drug side effects, behavioral factors and patient's mood. Careful consideration should be given to the use of self-reported measures of adherence among patients likely to be false-positive adherers.

  8. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    Science.gov (United States)

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  9. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  10. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence

    Directory of Open Access Journals (Sweden)

    Phillip eGrant

    2014-09-01

    Full Text Available Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals.In this study we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy.Our results support findings that both state and trait positive schizotypy explain significant variance in seeing things that are not there and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  11. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence.

    Science.gov (United States)

    Grant, Phillip; Balser, Mona; Munk, Aisha Judith Leila; Linder, Jens; Hennig, Juergen

    2014-01-01

    Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive) schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially, the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals. In this study, we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word, or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy. Our results support findings that both state and trait positive schizotypy explain significant variance in "seeing things that are not there" and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  12. Distinguishing Binders from False Positives by Free Energy Calculations: Fragment Screening Against the Flap Site of HIV Protease

    Science.gov (United States)

    2015-01-01

    Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630

  13. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    Science.gov (United States)

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the

  14. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    Science.gov (United States)

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested

  15. False colour backscatter electron images and their application during electron microprobe analysis of ores and host rocks

    International Nuclear Information System (INIS)

    Cousens, D.R.; French, D.H.; Ramsden, A.R.

    1989-01-01

    The limited contrast range of conventional black and white imaging does not enable full use to be made of the dynamic range of the video signal obtained from a scanning electron microscope or microprobe. The use of false colour substantially increases the information that can be derived from such images enabling relationships to be displayed that cannot be observed in black and white. This capability is now used extensively in combination with quantitative electron microprobe analysis as a research tool for ore characterization and host rocks studies related to minerals exploration in the CSIRO Div.sion of Exploration Geoscience. Thus the CAMEBAX scanning electron microprobe has been modified to allow digital images acquisition and software (IMAGE) developed which allows false colour backscatter electron (BSE) images to be obtained during the course of routine electron microprobe analysis. 1 fig

  16. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    Science.gov (United States)

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  17. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    Science.gov (United States)

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; phemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; phemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; pHemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  18. SU-E-I-88: Mammography Imaging: Does Positioning Matter?

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J; Szabunio, M [University of Kentucky, Lexington, KY (United States)

    2014-06-01

    Purpose: In mammography, compression is imperative for quality images and glandular radiation exposure dose. The thickness of the compressed breast directly determines mammography acquisition parameters. The compressed thickness varies due to variation in technologist practice, even for the same patient imaged at different time. This study is to investigate potential effect of the variation in breast positioning on radiation dose and image quality. Methods: Radiation dose at different thicknesses was measured with a BR-12 breast phantom for both conventional craniocaudal view and tomosynthesis in a Hologic Tomosynthesis mammography system. The CIRS stereotactic needle biopsy training phantom embedded dense masses and microcalcification in various sizes were imaged for image quality evaluation. Radiologists evaluated images. Clinical mammograms from the same patient but acquired at different time were retrospectively retrieved to evaluate potential effects of variation in positioning. Results: Acquisition parameters (kVp and mAs) increase with the increased phantom thickness. Radiation exposure increases following an exponential trend. The stereotactic phantom images showed loss of spatial and contrast resolution with inappropriate positioning. The compressed pressure may not be a good indicator for appropriate positioning. The inclusion of different amount of pectoralis muscle may lead to the same compressed pressure but different compressed thickness. The initial retrospective study of 3 patients showed that there were potential large variations in positioning the same patient at different examination time, resulting in large variations in patient radiation dose and image quality. Conclusion: Variations in patient positioning potentially influence patient radiation dose and image quality. The technologist has the critical responsibility to position patient to provide quality images in spite of different breast and body types. To reduce intra and inter practice

  19. Protein complex prediction via dense subgraphs and false positive analysis.

    Directory of Open Access Journals (Sweden)

    Cecilia Hernandez

    Full Text Available Many proteins work together with others in groups called complexes in order to achieve a specific function. Discovering protein complexes is important for understanding biological processes and predict protein functions in living organisms. Large-scale and throughput techniques have made possible to compile protein-protein interaction networks (PPI networks, which have been used in several computational approaches for detecting protein complexes. Those predictions might guide future biologic experimental research. Some approaches are topology-based, where highly connected proteins are predicted to be complexes; some propose different clustering algorithms using partitioning, overlaps among clusters for networks modeled with unweighted or weighted graphs; and others use density of clusters and information based on protein functionality. However, some schemes still require much processing time or the quality of their results can be improved. Furthermore, most of the results obtained with computational tools are not accompanied by an analysis of false positives. We propose an effective and efficient mining algorithm for discovering highly connected subgraphs, which is our base for defining protein complexes. Our representation is based on transforming the PPI network into a directed acyclic graph that reduces the number of represented edges and the search space for discovering subgraphs. Our approach considers weighted and unweighted PPI networks. We compare our best alternative using PPI networks from Saccharomyces cerevisiae (yeast and Homo sapiens (human with state-of-the-art approaches in terms of clustering, biological metrics and execution times, as well as three gold standards for yeast and two for human. Furthermore, we analyze false positive predicted complexes searching the PDBe (Protein Data Bank in Europe database in order to identify matching protein complexes that have been purified and structurally characterized. Our analysis shows

  20. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  1. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  2. PIPIDA scintigraphy for cholecystitis: false positives in alcoholism and total parenteral nutrition

    International Nuclear Information System (INIS)

    Shuman, W.P.; Gibbs, P.; Rudd, T.G.; Mack, L.A.

    1982-01-01

    A review of gallbladder scintigraphy in patients with potentially compromised hepatobiliary function revealed two groups in whom cholecystitis might be mistakenly diagnosed. In 200 consecutive hospitalized patients studied with technetium-99m-PIPIDA for acute cholecystitis or cholestasis, there were 41 alcoholics and 17 patients on total parenteral nutrition. In 60% of the alcoholics and 92% of those on parenteral nutrition, absent or delayed visualization of the gallbladder occurred without physical or clinical evidence of cholecystitis. A cholecystagogue, sincalide, did not prevent the false-positive features which presumably are due to altered bile flow kinetics related to alcoholism and parenteral nutrition. Four patients on parenteral nutrition undergoing cholecystectomy for suspected cholecystitis had normal gallbladders filled with jellylike viscous thick bile. A positive (nonvisualized or delayed visualized) gallbladder PIPIDA scintigram in these two populations should not be interpreted as indicating a need for cholecystectomy

  3. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    -ups at 2 and 12 months postscreening. At 2 months, there was a moderate multivariate effect of group on distress; and intrusive thinking and worry about breast cancer, in particular, were most frequent amongst the false positives. Intrusive thinking still prevailed at 12 months, in addition to a higher...... findings (n=1407), false-positive findings (n=492) and referents from outside the screening programme (n=1718, age 48-49 years). Distress was measured as illness worry, anxiety, depression, cancer beliefs and early detection behaviour. Measurements were one month before screening invitation with follow...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  4. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  5. Prenatal ultrasound screening: false positive soft markers may alter maternal representations and mother-infant interaction.

    Directory of Open Access Journals (Sweden)

    Sylvie Viaux-Savelon

    Full Text Available In up to 5% of pregnancies, ultrasound screening detects a "soft marker" (SM that places the foetus at risk for a severe abnormality. In most cases, prenatal diagnostic work-up rules out a severe defect. We aimed to study the effects of false positive SM on maternal emotional status, maternal representations of the infant, and mother-infant interaction.Utilizing an extreme-case prospective case control design, we selected from a group of 244 women undergoing ultrasound, 19 pregnant women whose foetus had a positive SM screening and a reassuring diagnostic work up, and 19 controls without SM matched for age and education. In the third trimester of pregnancy, within one week after delivery, and 2 months postpartum, we assessed anxiety, depression, and maternal representations. Mother-infant interactions were videotaped during feeding within one week after delivery and again at 2 months postpartum and coded blindly using the Coding Interactive Behavior (CIB scales. Anxiety and depression scores were significantly higher at all assessment points in the SM group. Maternal representations were also different between SM and control groups at all study time. Perturbations to early mother-infant interactions were observed in the SM group. These dyads showed greater dysregulation, lower maternal sensitivity, higher maternal intrusive behaviour and higher infant avoidance. Multivariate analysis showed that maternal representation and depression at third trimester predicted mother-infant interaction.False positive ultrasound screenings for SM are not benign and negatively affect the developing maternal-infant attachment. Medical efforts should be directed to minimize as much as possible such false diagnoses, and to limit their psychological adverse consequences.

  6. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  7. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  8. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    International Nuclear Information System (INIS)

    Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W.; Bryson, Stephen T.; Borucki, William J.; Knutson, Heather A.; Batalha, Natalie M.; Deming, Drake; Ford, Eric B.; Fortney, Jonathan J.; Gilliland, Ronald L.; Seager, Sara

    2015-01-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  9. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Désert, Jean-Michel; Brown, Timothy M. [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO 80309 (United States); Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bryson, Stephen T.; Borucki, William J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Batalha, Natalie M. [San Jose State University, San Jose, CA 95192 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Ford, Eric B. [University of Florida, Gainesville, FL 32611 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Gilliland, Ronald L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Seager, Sara, E-mail: desert@colorado.edu [Massachusetts Institute of Technology, Cambridge, MA 02159 (United States)

    2015-05-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  10. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  11. False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion

    International Nuclear Information System (INIS)

    Smits, P.; Corstens, F.H.; Aengevaeren, W.R.; Wackers, F.J.; Thien, T.

    1991-01-01

    The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsible for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 ± 0.9 to 2.0 ± 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% ± 16% to 6% ± 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings

  12. False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion

    Energy Technology Data Exchange (ETDEWEB)

    Smits, P.; Corstens, F.H.; Aengevaeren, W.R.; Wackers, F.J.; Thien, T. (University Hospital Nijmegen (Netherlands))

    1991-08-01

    The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsible for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 {plus minus} 0.9 to 2.0 {plus minus} 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% {plus minus} 16% to 6% {plus minus} 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings.

  13. A clinical study for radiotherapy positioning with references images on CT simulator

    International Nuclear Information System (INIS)

    Yang Bo; Sun Xiaoyang; Luo Huiqun; Wu Hong; Pang Haowen

    2011-01-01

    Objective: To explore a new method of comparing the references images first to enhance the precision of the central point of the radiation treatment planning (RTP), try to establish a reference standard for this method in the nasopharyngeal cancer (NPC) and carcinoma of utercin cervix in the work of position verification. Methods: For 50 RTPs of NPC and 20 RTPs of carcinoma of utercin cervix, the reference-CT-images in set-up and in position verification were compared, and to measure the difference between the two images. Then, in the same way, compare and measure the difference in the central-point-images. Results: For NPC, there was over 90% RTPs in which every difference measured was less than 2 mm;for carcinoma of utercin cervix, over 80% RTPs meet the criterion:the value of ΔMU 1 ' or ΔMU 2 ' was less than 5 mm and the others are less than 3 mm. Conclusions: By comparing the references-CT-images in set-up and in position verification, the precision of the central point of the RTP is enhanced. The marks on the skin become more credible. So, it is feasible to perform the criterions in the work of position verification: for NPC every difference measured is less than 2 mm; for carcinoma of utercin cervix the value of ΔMU 1 ' or ΔMU 2 ' is less than 5 mm and the others are less than 3 mm. (authors)

  14. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  15. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  16. An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening

    International Nuclear Information System (INIS)

    Nightingale, Julie M.; Borgen, Rita; Porter-Bennett, Lisa; Szczepura, Katy

    2015-01-01

    Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negative psychosocial consequences reported. Women are at increased relative risk of breast cancer therefore their attendance at subsequent screening is essential. Aims: To assess the impact of FP breast screening diagnosis and diagnostic work-up on re-attendance rates across four consecutive screening rounds at a typical breast screening centre. Method: Diagnostic interventions and screening re-attendance rates at one prior and two consecutive rounds were analysed for women receiving an FP diagnosis between 2004 and 2006. Results: 397 women (5.57%) were referred for further assessment, including 228 (57.43%) false positives. 34 eligible women failed to re-attend routine screening (+3 years), with 17 failing to re-attend subsequently (+6 years). 70.6% (24/34) of non-attenders had attended at least two screening rounds prior to FP assessment. 75% of FP women had an imaging-only assessment with 17.5% (30/171) failing to re-attend, and 25% received a biopsy, with 7% (4/57) failing to re-attend subsequently. Conclusion: This study is unique as it follows FP women through four consecutive screening rounds. FP non-attendance rates were considerably lower compared to the general screening population, with diagnostic work-up having limited influence. FP non-attendance may appear insignificant in comparison to total screened population, but these women are at greater risk of subsequent cancer so should be actively encouraged to re-engage with the screening programme

  17. False-positive head-impulse test in cerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Olympia eKremmyda

    2012-11-01

    Full Text Available Abstract:The objective of this study was to compare the findings of the bedside head impulse test (HIT, passive head rotation gain, and caloric irrigation in patients with cerebellar ataxia (CA. In 16 patients with CA and bilaterally pathological bedside HIT, VOR gains were measured during HIT and passive head rotation by scleral search coil technique. Eight of the patients had pathologically reduced caloric responsiveness, while the other eight had normal caloric responses. Those with normal calorics showed a slightly reduced HIT gain (mean±SD: 0.73±0.15. In those with pathological calorics, gains 80ms and 100 ms after the HIT as well as the passive rotation VOR gains were significantly lower. The corrective saccade after head turn occurred earlier in patients with pathological calorics (111±62 ms after onset of the HIT than in those with normal calorics. (191±17 ms, p=0.0064 We indentified two groups of patients with CA: those with an isolated moderate HIT deficit only, probably due to floccular dysfunction, and those with combined HIT, passive rotation and caloric deficit, probably due to a peripheral vestibular deficit. From a clinical point of view, these results show that the bedside HIT alone can be false positive for establishing a diagnosis of a bilateral peripheral vestibular deficit in patients with CA.

  18. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  19. "It's all about acceptance": A qualitative study exploring a model of positive body image for people with spinal cord injury.

    Science.gov (United States)

    Bailey, K Alysse; Gammage, Kimberley L; van Ingen, Cathy; Ditor, David S

    2015-09-01

    Using modified constructivist grounded theory, the purpose of the present study was to explore positive body image experiences in people with spinal cord injury. Nine participants (five women, four men) varying in age (21-63 years), type of injury (C3-T7; complete and incomplete), and years post-injury (4-36 years) were recruited. The following main categories were found: body acceptance, body appreciation and gratitude, social support, functional gains, independence, media literacy, broadly conceptualizing beauty, inner positivity influencing outer demeanour, finding others who have a positive body image, unconditional acceptance from others, religion/spirituality, listening to and taking care of the body, managing secondary complications, minimizing pain, and respect. Interestingly, there was consistency in positive body image characteristics reported in this study with those found in previous research, demonstrating universality of positive body image. However, unique characteristics (e.g., resilience, functional gains, independence) were also reported demonstrating the importance of exploring positive body image in diverse groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. A False Positive I-131 Metastatic Survey Caused by Radioactive Iodine Uptake by a Benign Thymic Cyst

    Directory of Open Access Journals (Sweden)

    Avneet K. Singh

    2017-01-01

    Full Text Available Thyroid carcinoma is the most common endocrine malignancy in the United States with increasing incidence and diagnosis but stable mortality. Differentiated thyroid cancer rarely presents with distant metastases and is associated with a low risk of morbidity and mortality. Despite this, current protocols recommend remnant ablation with radioactive iodine and evaluation for local and distant metastasis in some patients with higher risk disease. There are several case reports of false positive results of metastatic surveys that are either normal physiologic variants or other pathological findings. Most false positive findings are associated with tissue that has physiologic increased uptake of I-131, such as breast tissue or lung tissue; pathological findings such as thymic cysts are also known to have increased uptake. Our case describes a rare finding of a thymic cyst found on a false positive I-131 metastatic survey. The patient was taken for surgical excision and the final pathology was a benign thymic cyst. Given that pulmonary metastases of differentiated thyroid cancer are rare, thymic cysts, though also rare, must be part of the differential diagnosis for false positive findings on an I-131 survey.

  1. Benign oral pathology as a cause of false positive 131I uptake in thyroid carcinoma

    International Nuclear Information System (INIS)

    Mansberg, R.; Wadhwa, S.S.; Fernandes, V.B.

    1997-01-01

    Full text: We present three thyroidectomised patients with a history of thyroid carcinoma who had non-metastatic 131 I uptake due to benign oral pathology. A salivary gland study suggested impaired function but no obstruction was demonstrated on a sialogram. The symptoms resolved on antibiotic therapy and a subsequent 131 I study was normal. A subsequent thallium study demonstrated physiological tracer distribution. A 35-year-old female with papillary cell carcinoma of the thyroid demonstrated a focus of uptake on the right hemi-mandible following both a diagnostic and a therapeutic dose of 131 I. This area was tender and an OPG confirmed an area of liquefaction at this site. A 53-year-old female with medullary cell carcinoma of the thyroid demonstrated a focus of uptake in the right side of the maxilla following a diagnostic administration of 131 I. An OPG confirmed an area of liquefaction around the apex of the right upper centre. These three cases illustrate salivary gland and dental inflammation as causes of false positive 131 I uptake. It is important to differentiate non-metastatic 131 I uptake from that due to functioning metastatic thyroid carcinoma in order to avoid inappropriate treatment with large additional doses of 131 I. As in these patients, clinical assessment and the use of anatomical imaging or other isotopes such as thallium or technetium can be helpful in ruling out a mistaken diagnosis of metastasis

  2. PET Study with false positive {sup 68}Ga-Dotatate caused by the presence of an accessory spleen; Estudio PET con {sup 68}Ga-Dotatate falso positivo causado por la presencia de un bazo accesorio

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago / Seccion Medicina Nuclear, Departamento Medicina, Hospital Clinico Universidad de Chile. Santiago (Chile); Jofre, Josefina; Sierralta, M. Paulina; Canessa, Jose [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago. Santiago (Chile)

    2013-05-31

    Neuroendocrine tumors with somatostatin receptor expression are suitable for imaging with somatostatin analogues. {sup 68}Ga-labeled peptides are useful for the diagnosis, staging and assessment of therapeutic response of these tumors. However, for a correct interpretation it is necessary to know the normal biodistribution of somatostatin receptors in the body. Asymmetric adrenal uptake may be a normal variant to cause confusion, or an accessory or ectopic spleen can lead to a false positive result. We report a case of asymmetric adrenal uptake which was correctly considered as a normal variant, but an accessory spleen caused the false impression of being a metastasis from a previously resected primary carcinoid tumor.

  3. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  4. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  5. AN APPROACH TO ALLEVIATE THE FALSE ALARM IN BUILDING CHANGE DETECTION FROM URBAN VHR IMAGE

    Directory of Open Access Journals (Sweden)

    J. Chen

    2016-06-01

    Full Text Available Building change detection from very-high-resolution (VHR urban remote sensing image frequently encounter the challenge of serious false alarm caused by different illumination or viewing angles in bi-temporal images. An approach to alleviate the false alarm in urban building change detection is proposed in this paper. Firstly, as shadows casted by urban buildings are of distinct spectral and shape feature, it adopts a supervised object-based classification technique to extract them in this paper. Secondly, on the opposite direction of sunlight illumination, a straight line is drawn along the principal orientation of building in every extracted shadow region. Starting from the straight line and moving toward the sunlight direction, a rectangular area is constructed to cover partial shadow and rooftop of each building. Thirdly, an algebra and geometry invariant based method is used to abstract the spatial topological relationship of the potential unchanged buildings from all central points of the rectangular area. Finally, based on an oriented texture curvature descriptor, an index is established to determine the actual false alarm in building change detection result. The experiment results validate that the proposed method can be used as an effective framework to alleviate the false alarm in building change detection from urban VHR image.

  6. Neural Network Target Identification System for False Alarm Reduction

    Science.gov (United States)

    Ye, David; Edens, Weston; Lu, Thomas T.; Chao, Tien-Hsin

    2009-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

  7. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  8. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  9. False Positive Findings on I-131 WBS and SPECT/CT in Patients with History of Thyroid Cancer: Case Series

    Directory of Open Access Journals (Sweden)

    Zeina C. Hannoush

    2017-01-01

    Full Text Available Introduction. Although whole body scan (WBS with I-131 is a highly sensitive tool for detecting normal thyroid tissue and metastasis of differentiated thyroid cancer (DTC, it is not specific. Additional information, provided by single photon emission computed tomography combined with X-ray computed tomography (SPECT/CT and by the serum thyroglobulin level, is extremely useful for the interpretation of findings. Case Presentation. We report four cases of false positive WBS in patients with DTC: ovarian uptake corresponding to an endometrioma, scrotal uptake due to a spermatocele, rib-cage uptake due to an old fracture, and hepatic and renal uptake secondary to a granuloma and simple cyst, respectively. Conclusions. Trapping, organification, and storage of iodine are more prominent in thyroid tissue but not specific. Physiologic sodium-iodine symporter expression in other tissues explains some, but not all, of the WBS false positive cases. Other proposed etiologies are accumulation of radioiodine in inflamed organs, metabolism of radiodinated thyroid hormone, presence of radioiodine in body fluids, and contamination. In our cases nonthyroidal pathologies were suspected since the imaging findings were not corroborated by an elevated thyroglobulin level, which is considered a reliable tumor marker for most well-differentiated thyroid cancers. Clinicians should be aware of the potential pitfalls of WBS in DTC to avoid incorrect management.

  10. One Hundred False-Positive Amphetamine Specimens Characterized by Liquid Chromatography Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Marin, Stephanie J; Doyle, Kelly; Chang, Annie; Concheiro-Guisan, Marta; Huestis, Marilyn A; Johnson-Davis, Kamisha L

    2016-01-01

    Some amphetamine (AMP) and ecstacy (MDMA) urine immunoassay (IA) kits are prone to false-positive results due to poor specificity of the antibody. We employed two techniques, high-resolution mass spectrometry (HRMS) and an in silico structure search, to identify compounds likely to cause false-positive results. Hundred false-positive IA specimens for AMP and/or MDMA were analyzed by an Agilent 6230 time-of-flight (TOF) mass spectrometer. Separately, SciFinder (Chemical Abstracts) was used as an in silico structure search to generate a library of compounds that are known to cross-react with AMP/MDMA IAs. Chemical formulas and exact masses of 145 structures were then compared against masses identified by TOF. Compounds known to have cross-reactivity with the IAs were identified in the structure-based search. The chemical formulas and exact masses of 145 structures (of 20 chemical formulas) were compared against masses identified by TOF. Urine analysis by HRMS correlates accurate mass with chemical formulae, but provides little information regarding compound structure. Structural data of targeted antigens can be utilized to correlate HRMS-derived chemical formulas with structural analogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Interpreting the results of the Semmes-Weinstein monofilament test: accounting for false-positive answers in the international consensus on the diabetic foot protocol by a new model.

    Science.gov (United States)

    Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J

    2014-01-01

    The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.

  12. University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleissl, J. [Univ. of California, San Diego, CA (United States); Urquhart, B. [Univ. of California, San Diego, CA (United States); Ghonima, M. [Univ. of California, San Diego, CA (United States); Dahlin, E. [Univ. of California, San Diego, CA (United States); Nguyen, A. [Univ. of California, San Diego, CA (United States); Kurtz, B. [Univ. of California, San Diego, CA (United States); Chow, C. W. [Univ. of California, San Diego, CA (United States); Mejia, F. A. [Univ. of California, San Diego, CA (United States)

    2016-04-01

    During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

  13. Detecting and avoiding likely false-positive findings - a practical guide.

    Science.gov (United States)

    Forstmeier, Wolfgang; Wagenmakers, Eric-Jan; Parker, Timothy H

    2017-11-01

    Recently there has been a growing concern that many published research findings do not hold up in attempts to replicate them. We argue that this problem may originate from a culture of 'you can publish if you found a significant effect'. This culture creates a systematic bias against the null hypothesis which renders meta-analyses questionable and may even lead to a situation where hypotheses become difficult to falsify. In order to pinpoint the sources of error and possible solutions, we review current scientific practices with regard to their effect on the probability of drawing a false-positive conclusion. We explain why the proportion of published false-positive findings is expected to increase with (i) decreasing sample size, (ii) increasing pursuit of novelty, (iii) various forms of multiple testing and researcher flexibility, and (iv) incorrect P-values, especially due to unaccounted pseudoreplication, i.e. the non-independence of data points (clustered data). We provide examples showing how statistical pitfalls and psychological traps lead to conclusions that are biased and unreliable, and we show how these mistakes can be avoided. Ultimately, we hope to contribute to a culture of 'you can publish if your study is rigorous'. To this end, we highlight promising strategies towards making science more objective. Specifically, we enthusiastically encourage scientists to preregister their studies (including a priori hypotheses and complete analysis plans), to blind observers to treatment groups during data collection and analysis, and unconditionally to report all results. Also, we advocate reallocating some efforts away from seeking novelty and discovery and towards replicating important research findings of one's own and of others for the benefit of the scientific community as a whole. We believe these efforts will be aided by a shift in evaluation criteria away from the current system which values metrics of 'impact' almost exclusively and towards a system

  14. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  15. False Advertising

    OpenAIRE

    Rhodes, Andrew; Wilson, Chris M

    2016-01-01

    There is widespread evidence that some firms use false advertising to overstate the value of their products. We consider a model in which a policymaker is able to punish such false claims. We characterize an equilibrium where false advertising actively influences rational buyers, and analyze the effects of policy under different welfare objectives. We establish precise conditions where policy optimally permits a positive level of false advertising, and show how these conditions vary intuitive...

  16. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  17. False-Positive Rate Determination of Protein Target Discovery using a Covalent Modification- and Mass Spectrometry-Based Proteomics Platform

    Science.gov (United States)

    Strickland, Erin C.; Geer, M. Ariel; Hong, Jiyong; Fitzgerald, Michael C.

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2 % and analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  18. STUDY ON MODELING AND VISUALIZING THE POSITIONAL UNCERTAINTY OF REMOTE SENSING IMAGE

    Directory of Open Access Journals (Sweden)

    W. Jiao

    2016-06-01

    Full Text Available It is inevitable to bring about uncertainty during the process of data acquisition. The traditional method to evaluate the geometric positioning accuracy is usually by the statistical method and represented by the root mean square errors (RMSEs of control points. It is individual and discontinuous, so it is difficult to describe the error spatial distribution. In this paper the error uncertainty of each control point is deduced, and the uncertainty spatial distribution model of each arbitrary point is established. The error model is proposed to evaluate the geometric accuracy of remote sensing image. Then several visualization methods are studied to represent the discrete and continuous data of geometric uncertainties. The experiments show that the proposed evaluation method of error distribution model compared with the traditional method of RMSEs can get the similar results but without requiring the user to collect control points as checkpoints, and error distribution information calculated by the model can be provided to users along with the geometric image data. Additionally, the visualization methods described in this paper can effectively and objectively represents the image geometric quality, and also can help users probe the reasons of bringing the image uncertainties in some extent.

  19. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  20. Early Disseminated Lyme Disease Causing False-Positive Serology for Primary Epstein-Barr Virus Infection: Report of 2 Cases.

    Science.gov (United States)

    Pavletic, Adriana J; Marques, Adriana R

    2017-07-15

    False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  1. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  2. In-111 WBC imaging in musculoskeletal sepsis

    International Nuclear Information System (INIS)

    Thompson, L.; Ouzounian, T.J.; Webber, M.M.; Amstutz, H.C.

    1984-01-01

    This study evaluated the accuracy and utility of the In-111 labeled WBC imaging in a series of patients who were suspected of having musculoskeletal sepsis. The labeling of the WBCs was patterned after a method previously described, in which the WBCs are labeled with In-111 oxine in plasma. The WBCs from 100 ml of blood are separated and incubated with In-111 oxine complex, and then 500 μCi. of the labeled cells were reinjected into the patient. Images of the areas in question were obtained at 24 hrs. In some instances, 48 hour images were also obtained. Images were interpreted using consistent criteria. Forty imaging procedures were done on 39 patients. These included 39 total joint protheses, and 17 other images to evaluate possible osteomyelitis, septic arthritis or deep abscesses. Of these studies, 15 were positive, and 42 negative. The findings were then correlated with operative culture and pathology in 21, aspiration cultures and gram stains in 14, and with clinical findings in the remaining 21. This correlation showed 41 true negatives, 12 true positives, 1 false negative, and 2 false positives. The sensitivity was 92.9% and the specificity was 95.2%l. The false negative occurred in a patient on chronic suppressive antibiotic therapy for an infected total hip replacement. The false positive images occurred in a patient with active rheumatoid arthritis and in a patient imaged one month post operative placement of the prosthesis. These images were very useful in several septic patients who had many possible sites of infection. The authors conclude that In-III imaging is an accurate and useful non-invasive method of evaluating musculoskeletal sepsis

  3. Positive post-disaster images: A daydream machine?

    Science.gov (United States)

    Hancock, Nicola J; de Joux, Neil R; Wingreen, Stephen C; Kemp, Simon; Thomas, Jared; Helton, William S

    2017-08-01

    This study explores the impact of post-earthquake images inserted in a vigilance task, in terms of performance, self-reports of task-focus, and cerebral activity using functional near-infrared spectroscopy (fNIRS). Vigilance tasks present a sequence of stimuli in which only a few are pre-designated critical or target stimuli requiring an overt response from the participant. Seventy-one residents participated (51 women, 20 men) by taking part in a vigilance task with task-irrelevant images inserted in the sequence. There were three conditions consisting positive (emotive inducing), negative (emotive inducing), and control (devoid of meaning) images embedded in the vigilance task to assess possible impacts on vigilance performance. The images were obtained through crowdsourcing and represented parts of the city 3-4 years post-earthquake. Task performance was assessed with signal detection theory metrics of sensitivity A' and bias β''. This enables the separation of an individual's ability to accurately discriminate critical signals from non-critical stimuli (sensitivity) and shifts in their willingness to respond to any stimuli whether critical or not (bias). Individuals viewing the positive images, relating to progress, rebuild, or aesthetic aspects within the city, had a more conservative response bias (they responded less to both rare critical and distractor stimuli) than those in the other conditions. These individuals also reported lower task-focus, as would be expected. However, contrary to expectations, indicators of cerebral activity (fNIRS) did not differ significantly between the experimental groups. These results, when combined, suggest that mind wandering events may be being generated when exposed to positive post-earthquake images. © 2016 The British Psychological Society.

  4. Efficacy of 67 gallium ECT imaging in lymphoma, infection, and lung carcinoma: A comparison with planar imaging

    International Nuclear Information System (INIS)

    Harwood, S.J.; Anderson, M.W.; Klein, R.C.; Friedman, B.I.; Carroll, R.G.

    1984-01-01

    Emission computed tomography (ECT) studies were performed on a GE 400 A/T camera and ADAC computers (system 3 and system 3300). Thirty-three sets of ECT and planar images were obtained in 20 patients over a six month period. Imaging was performed 48 hours after the intravenous administration of 5 mc of Gallium 67 citrate. No bowel preparation was employed. Comparison is made of the initial nuclear medicine report derived from planar and ECT imaging aided by clinical knowledge versus the consensus opinion of two nuclear medicine physicians reading the planar images along with minimal clinical information. The lymphoma series consists of 18 scans in 10 patients. There were 5 scans in which a false negative planar interpretation was changed to a true positive ECT interpretation. Sensitivity of planar imaging for lymphoma was 58% which rose to 100% with addition of ECT information. There were no false positives by either technique. There were 5 sets of scans in 5 lung carcinoma patients. Sensitivity of the planar images was 60% because of 2 false negative results. Sensitivity of the ECT technique was 100%. There were no false positives. The infection series consists of 10 scans in 5 patients. Sensitivity of ECT was 100%, sensitivity of planar was 66%. There was 1 false positive planar. For the total series the accuracy of planar imaging was 69% and the predictive value of a negative planar interpretation was 44%. Corresponding values for ECT imaging were 100%. The authors' experience demonstrates significant increase in sensitivity without loss of specificity resulting from the use of Emission Computed Tomography in both chest and abdomen in patients with lymphoma, infection, and lung cancer

  5. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  6. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  7. High energy electron radiography system design and simulation study of beam angle-position correlation and aperture effect on the images

    International Nuclear Information System (INIS)

    Zhao, Quantang; Cao, S.C.; Liu, M.; Sheng, X.K.; Wang, Y.R.; Zong, Y.; Zhang, X.M.; Jing, Y.; Cheng, R.; Zhao, Y.T.; Zhang, Z.M.; Du, Y.C.; Gai, W.

    2016-01-01

    A beam line dedicated to high-energy electron radiography experimental research with linear achromat and imaging lens systems has been designed. The field of view requirement on the target and the beam angle-position correlation correction can be achieved by fine-tuning the fields of the quadrupoles used in the achromat in combination with already existing six quadrupoles before the achromat. The radiography system is designed by fully considering the space limitation of the laboratory and the beam diagnostics devices. Two kinds of imaging lens system, a quadruplet and an octuplet system are integrated into one beam line with the same object plane and image plane but with different magnification factor. The beam angle-position correlation on the target required by the imaging lens system and the aperture effect on the images are studied with particle tracking simulation. It is shown that the aperture position is also correlated to the beam angle-position on the target. With matched beam on the target, corresponding aperture position and suitable aperture radius, clear pictures can be imaged by both lens systems. The aperture is very important for the imaging. The details of the beam optical requirements, optimized parameters and the simulation results are presented.

  8. Cross-reactive Carbohydrate Determinant Contributes to the False Positive IgE Antibody to Peanut

    Directory of Open Access Journals (Sweden)

    Komei Ito

    2005-01-01

    Conclusions: Social education about the features of peanut allergy is needed in Japan. Anti-CCD IgE antibody was suggested to be one of the mechanisms contributing to the false positive detection of peanut IgE. Detection of anti-HRP or anti-bromelain IgE can be a useful tool to recognize the presence of anti-CCD antibodies.

  9. A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

    International Nuclear Information System (INIS)

    Sliski, David H.; Kipping, David M.

    2014-01-01

    Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

  10. Challenges and Strategies to Develop a Positive Image of the Library

    Directory of Open Access Journals (Sweden)

    Anisa Sri Restanti

    2018-01-01

    Full Text Available Information technology has been used in the management of the library. There are several libraries have been integrated with the internet to provide services. But the library still image as an institution or an old building that contains the bookshelves and librarian profession under other professions. This article is presented to determine some of the challenges and strategies that can be done in fostering a positive image of the library. Based on the literature study and observation, it’s known, that the challenges are differences in educational background librarians, foster a positive image has not been planned, the development of information technology, the implementation of the code of ethics of librarians is not maximal. In the face of the challenges in creating a positive image, there are strategies that can be done that in terms of internal and external libraries. Thus, it can be concluded that, to foster a positive image of the library is needed strategies and synergies as well as the responsibility of all aspects of the library. Recommendation for librarians are important to develop personal branding. Furthermore, for the library after successfully building a positive image should be able to maintain and restore the image when a crisis.

  11. Challenges and Strategies to Develop a Positive Image of the Library

    Directory of Open Access Journals (Sweden)

    Anisa Sri Restanti

    2017-01-01

    Full Text Available Information technology has been used in the management of the library. There are several libraries have been integrated with the internet to provide services. But the library still image as an institution or an old building that contains the bookshelves and librarian profession under other professions. This article is presented to determine some of the challenges and strategies that can be done in fostering a positive image of the library. Based on the literature study and observation, its known, that the challenges are differences in educational background librarians, foster a positive image has not been planned, the development of information technology, the implementation of the code of ethics of librarians is not maximal. In the face of the challenges in creating a positive image, there are strategies that can be done that in terms of internal and external libraries. Thus, it can be concluded that, to foster a positive image of the library is needed strategies and synergies as well as the responsibility of all aspects of the library. Recommendation for librarians are important to develop personal branding. Furthermore, for the library after successfully building a positive image should be able to maintain and restore the image when a crisis.

  12. Yoga and positive body image: A test of the Embodiment Model.

    Science.gov (United States)

    Mahlo, Leeann; Tiggemann, Marika

    2016-09-01

    The study aimed to test the Embodiment Model of Positive Body Image (Menzel & Levine, 2011) within the context of yoga. Participants were 193 yoga practitioners (124 Iyengar, 69 Bikram) and 127 university students (non-yoga participants) from Adelaide, South Australia. Participants completed questionnaire measures of positive body image, embodiment, self-objectification, and desire for thinness. Results showed yoga practitioners scored higher on positive body image and embodiment, and lower on self-objectification than non-yoga participants. In support of the embodiment model, the relationship between yoga participation and positive body image was serially mediated by embodiment and reduced self-objectification. Although Bikram practitioners endorsed appearance-related reasons for participating in yoga more than Iyengar practitioners, there were no significant differences between Iyengar and Bikram yoga practitioners on body image variables. It was concluded that yoga is an embodying activity that can provide women with the opportunity to cultivate a favourable relationship with their body. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A comparative study of 99Tcm (V)-DMSA imaging with histopathological examination in ovarian neoplasms

    International Nuclear Information System (INIS)

    Zhao Xinming; Wang Jianfang; Xu Fang; Yin Jie; Wei Lanxiu; Sun Li

    1999-01-01

    Objective: To assess the clinical value of 99 Tc m (V)-Dmsa imaging in detecting the ovarian and the pelvic cavity neoplasms. Methods: 99 Tc m (V)-DMSA imaging was performed on 24 patients with diagnosed ovarian neoplasms which were pathologically confirmed after operation. Results: 14 of the 15 patients with malignant ovarian tumors had positive 99 Tc m (V)-DMSA scintigraphy. However, 7 of 9 cases with benign ovarian tumors had negative 99 Tc m (V)-DMSA scintigraphy. The sensitivity, specificity, positive predictive value, negative predictive value, false positive rate, false negative rate, and accuracy of 99 Tc m (V)-DMSA imaging for detecting malignant ovarian tumors were 93.33%, 77.78%, 87.50%, 87.50%, 14.29%, 6.67% and 87.50%, respectively. Conclusions: 99 Tc m (V)-DMSA imaging is of important value in detecting malignant and benign ovarian and pelvic tumors

  14. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  15. Optical image-hiding method with false information disclosure based on the interference principle and partial-phase-truncation in the fractional Fourier domain

    International Nuclear Information System (INIS)

    Dai, Chaoqing; Wang, Xiaogang; Zhou, Guoquan; Chen, Junlang

    2014-01-01

    An image-hiding method based on the optical interference principle and partial-phase-truncation in the fractional Fourier domain is proposed. The primary image is converted into three phase-only masks (POMs) using an analytical algorithm involved partial-phase-truncation and a fast random pixel exchange process. A procedure of a fake silhouette for a decryption key is suggested to reinforce the encryption and give a hint of the position of the key. The fractional orders of FrFT effectively enhance the security of the system. In the decryption process, the POM with false information and the other two POMs are, respectively, placed in the input and fractional Fourier planes to recover the primary image. There are no unintended information disclosures and iterative computations involved in the proposed method. Simulation results are presented to verify the validity of the proposed approach. (letters)

  16. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  17. Predictors and Health-Related Outcomes of Positive Body Image in Adolescent Girls: A Prospective Study

    Science.gov (United States)

    Andrew, Rachel; Tiggemann, Marika; Clark, Levina

    2016-01-01

    This study aimed to investigate prospective predictors and health-related outcomes of positive body image in adolescent girls. In so doing, the modified acceptance model of intuitive eating was also examined longitudinally. A sample of 298 girls aged 12 to 16 years completed a questionnaire containing measures of body appreciation, potential…

  18. The semantics of emotion in false memory.

    Science.gov (United States)

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  19. A critical reappraisal of false negative sentinel lymph node biopsy in melanoma

    International Nuclear Information System (INIS)

    Manca, G.; Mazzarri, S.; Boni, G.; Chiacchio, S.; Tredici, M.; Duce, V.; Tardelli, E.; Volterrani, D.; Mariani, G.; Romanini, A.; Rubello, D.

    2014-01-01

    Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of “actual” positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the

  20. False Positive Stress Testing: Does Endothelial Vascular Dysfunction Contribute to ST-Segment Depression in Women? A Pilot Study.

    Science.gov (United States)

    Sharma, Shilpa; Mehta, Puja K; Arsanjani, Reza; Sedlak, Tara; Hobel, Zachary; Shufelt, Chrisandra; Jones, Erika; Kligfield, Paul; Mortara, David; Laks, Michael; Diniz, Marcio; Bairey Merz, C Noel

    2018-06-19

    The utility of exercise-induced ST-segment depression for diagnosing ischemic heart disease (IHD) in women is unclear. Based on evidence that IHD pathophysiology in women involves coronary vascular dysfunction, we hypothesized that coronary vascular dysfunction contributes to exercise electrocardiography (Ex-ECG) ST-depression in the absence of obstructive CAD, so-called "false positive" results. We tested our hypothesis in a pilot study evaluating the relationship between peripheral vascular endothelial function and Ex-ECG. Twenty-nine asymptomatic women without cardiac risk factors underwent maximal Bruce protocol exercise treadmill testing and peripheral endothelial function assessment using peripheral arterial tonometry (Itamar EndoPAT 2000) to measure reactive hyperemia index (RHI). The relationship between RHI and Ex-ECG ST-segment depression was evaluated using logistic regression and differences in subgroups using two-tailed t-tests. Mean age was 54 ± 7 years, body mass index 25 ± 4 kg/m 2 , and RHI 2.51 ± 0.66. Three women (10%) had RHI less than 1.68, consistent with abnormal peripheral endothelial function, while 18 women (62%) met criteria for a positive Ex-ECG based on ST-segment depression in contiguous leads. Women with and without ST-segment depression had similar baseline and exercise vital signs, metabolic equivalents (METS) achieved, and RHI (all p>0.05). RHI did not predict ST-segment depression. Our pilot study demonstrates a high prevalence of exercise-induced ST-segment depression in asymptomatic, middle-aged, overweight women. Peripheral vascular endothelial dysfunction did not predict Ex-ECG ST-segment depression. Further work is needed to investigate the utility of vascular endothelial testing and Ex-ECG for IHD diagnostic and management purposes in women. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Reduction of lymph tissue false positives in pulmonary embolism detection

    Science.gov (United States)

    Ghanem, Bernard; Liang, Jianming; Bi, Jinbo; Salganicoff, Marcos; Krishnan, Arun

    2008-03-01

    Pulmonary embolism (PE) is a serious medical condition, characterized by the partial/complete blockage of an artery within the lungs. We have previously developed a fast yet effective approach for computer aided detection of PE in computed topographic pulmonary angiography (CTPA),1 which is capable of detecting both acute and chronic PEs, achieving a benchmark performance of 78% sensitivity at 4 false positives (FPs) per volume. By reviewing the FPs generated by this system, we found the most dominant type of FP, roughly one third of all FPs, to be lymph/connective tissue. In this paper, we propose a novel approach that specifically aims at reducing this FP type. Our idea is to explicitly exploit the anatomical context configuration of PE and lymph tissue in the lungs: a lymph FP connects to the airway and is located outside the artery, while a true PE should not connect to the airway and must be inside the artery. To realize this idea, given a detected candidate (i.e. a cluster of suspicious voxels), we compute a set of contextual features, including its distance to the airway based on local distance transform and its relative position to the artery based on fast tensor voting and Hessian "vesselness" scores. Our tests on unseen cases show that these features can reduce the lymph FPs by 59%, while improving the overall sensitivity by 3.4%.

  2. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    Directory of Open Access Journals (Sweden)

    Fuminori Sakurai

    2016-01-01

    Full Text Available Circulating tumor cells (CTCs are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP–expressing conditionally replicating adenovirus (Ad (rAd-GFP was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells.

  3. Unusual False Positive Radioiodine Uptake on 131I Whole Body Scintigraphy in Three Unrelated Organs with Different Pathologies in Patients of Differentiated Thyroid Carcinoma: A Case Series

    International Nuclear Information System (INIS)

    Ranade, Rohit; Pawar, Shwetal; Mahajan, Abhishek; Basu, Sandip

    2016-01-01

    Three cases with unusual false positive radioiodine uptake in three different organs and pathologies (infective old fibrotic lesion in the lung, simple liver cyst, and benign breast lesion) on iodine-131 ( 131 I) whole body scintigraphy. Clinicoradiological correlation was undertaken in all three cases and the pathologies were ascertained. In all the three cases, single-photon emission computerized tomography-computed tomography (SPECT-CT) and ancillary imaging modalities were employed and were helpful in arriving at the final diagnosis

  4. False Memories for Affective Information in Schizophrenia.

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p  false memories ( p  > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  5. False Memories for Affective Information in Schizophrenia

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600

  6. Localization diagnosis of hyperfunctional parathyroid gland using 99Tcm-MIBI and 99TcmO4- imaging

    International Nuclear Information System (INIS)

    Zhang Fenru; Deng Huixing; Duan Xiaoyi; Xue Jianjun; Gao Rui

    2010-01-01

    Objective: To study the localization diagnosis value of nuclide imaging by 99 Tc m -MIBI double phase parathyroid combined with 99 Tc m O 4 - thyroid imaging in patients with hyperparathyroidism (HPT). Methods: Patients with primary HPT were 36 cases. Control groups were 10 cases with thyroid disease. Early phase imaging was performed in 15 minute after injecting imaging agent 99 Tc m -MIBI. Delay phase imaging was performed in 2 hours. 36 HPT patients and 10 cases control groups were also performed 99 Tc m O 4 - thyroid imaging 24 hours later. The two kinds of imaging were compared with each other, were analyzed, and were underwent imaging subtracted by eyes and imaging results judgment. Results: In 36 cases of HPT patients, 34 cases showed positive result imaging with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. 2 cases showed false negative result. Positive rate was 94.44 % with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. The positive result imaging showed abnormal increased uptake of 99 Tc m -MIBI. In 36 cases of HPT patients, 12 cases showed positive result with single 99 Tc m -MIBI imaging. 4 cases showed false negative imaging. 20 cases showed ambiguous positive results. Positive rate was 88.89% (55.56% was ambiguous positive results) with single 99 Tc m -MIBI imaging. In 10 cases control groups, 3 cases showed false positive results with single 99 Tc m -MIBI imaging. 1 case showed ambiguous false positive results. No case showed false positive result with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. Conclusion: 99 Tc m -MIBI parathyroid double phase imaging combined with 99 Tc m O 4 - thyroid imaging have important value for diagnoses and localization of hyperparathyroidism. 99 Tc m -MIBI/ 99 Tc m O 4 - imaging have higher positive rate and higher specificity than single 99 Tc m -MIBI imaging for diagnoses and localization of hyperfunction parathyroid gland. (authors)

  7. Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy

    International Nuclear Information System (INIS)

    Sawada, Akira; Yoda, Kiyoshi; Numano, Masumi; Futami, Yasuyuki; Yamashita, Haruo; Murayama, Shigeyuki; Tsugami, Hironobu

    2005-01-01

    A new technique based on normalized binary image correlation between two edge images has been proposed for positioning proton-beam radiotherapy patients. A Canny edge detector was used to extract two edge images from a reference x-ray image and a test x-ray image of a patient before positioning. While translating and rotating the edged test image, the absolute value of the normalized binary image correlation between the two edge images is iteratively maximized. Each time before rotation, dilation is applied to the edged test image to avoid a steep reduction of the image correlation. To evaluate robustness of the proposed method, a simulation has been carried out using 240 simulated edged head front-view images extracted from a reference image by varying parameters of the Canny algorithm with a given range of rotation angles and translation amounts in x and y directions. It was shown that resulting registration errors have an accuracy of one pixel in x and y directions and zero degrees in rotation, even when the number of edge pixels significantly differs between the edged reference image and the edged simulation image. Subsequently, positioning experiments using several sets of head, lung, and hip data have been performed. We have observed that the differences of translation and rotation between manual positioning and the proposed method were within one pixel in translation and one degree in rotation. From the results of the validation study, it can be concluded that a significant reduction in workload for the physicians and technicians can be achieved with this method

  8. Rotator cuff tears: should abduction and external rotation (ABER) positioning be performed before image acquisition? A CT arthrography study

    Energy Technology Data Exchange (ETDEWEB)

    Cochet, Hubert [Hopital Cardiologique du Haut-Leveque, CHU Bordeaux, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Couderc, Stephane; Pele, Eric; Moreau-Durieux, Marie-Helene; Hauger, Olivier [Hopital Pellegrin, CHU Bordeaux, Unite d' Imagerie Osteo-articulaire, Bordeaux (France); Amoretti, Nicolas [CHU Archet, Unite d' Imagerie Osteo-articulaire, Nice (France)

    2010-05-15

    To evaluate the impact of abduction and external rotation (ABER) positioning performed before image acquisition on the assessment of rotator cuff tears. Twenty-seven consecutive patients with clinically suspected rotator cuff tears underwent an initial CT arthrogram of the shoulder in neutral position, immediately followed by temporary ABER positioning, before a second CT acquisition in neutral position. Two observers blinded to potential pre-procedure ABER positioning independently analysed the randomly distributed images. Lesions were classified into partial-thickness (PT) and full-thickness (FT) tear subtypes. Lesion detection and measurements of pre- and post-ABER studies were compared. We found no influence of pre-test ABER positioning on FT detection or measurements. Every PT detected on pre-ABER study was also detected on post-ABER study (28/28 for reader 1, and 32/32 for reader 2). Seven and eight additional PT were found by readers 1 and 2, respectively, on post-ABER study. Lesion size increased after ABER in terms of area (P < 0.001 for both readers) and Ellman's grade (P = 0.02 and 0.002 for reader 1 and 2, respectively). ABER positioning before CT is associated with improved delineation of partial tears, a higher number of detected tears and modification of treatment planning. (orig.)

  9. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography

  10. Evaluation of accuracy in target positions of multmodality imaging using brain phantom

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R. H.; Suh, T. S.; Chung, Y. A. [The Catholic University of Korea, Seoul (Korea, Republic of)

    2002-07-01

    Determination of target positions in radiation therapy or radiosurgery is critical to the successful treatment. It is often difficult to recognize the target position only from single image modality since each image modality has unique image pattern and image distortion problem. The purpose of this study is to evaluate the accuracy of target positions with multimodality brain phantom. We obtained CT, MR, and SPECT scan images with the specially designed brain phantom. Brain phantom consists of brain for images and frame for localization. The phantom was a water fillable cylinder containing 58 axial layers of 2.0 mm thickness. Each layer allows water to permeate various regions to match gray matter to white matter of 1:1 ratio. Localization frame with 5mm inner diameter and 150/160 mm length were attached to the outside of the brain slice and inside of the phantom cylinder. The phantom was filled with 0.16 M CuSO{sub 4} solution for MRI scan, and distilled water for CT and 15mCi (555 MBq) Tc-99m for SPECT. Axial slice images and volume images including the targets and localizer were obtained for each modality. To evaluate the errors in target positions, the position of localization and target balls measured in SPECT were compared with MR and CT. Transformation parameters for translation, rotation and scaling were determined by surface matching each SPECT with MR and CT images. Multimodality phantom was very useful to evaluate the accuracy of target positions among the different types of image modality such as CT, MR and SPECT.

  11. Shape based automated detection of pulmonary nodules with surface feature based false positive reduction

    International Nuclear Information System (INIS)

    Nomura, Y.; Itoh, H.; Masutani, Y.; Ohtomo, K.; Maeda, E.; Yoshikawa, T.; Hayashi, N.

    2007-01-01

    We proposed a shape based automated detection of pulmonary nodules with surface feature based false positive (FP) reduction. In the proposed system, the FP existing in internal of vessel bifurcation is removed using extracted surface of vessels and nodules. From the validation with 16 chest CT scans, we find that the proposed CAD system achieves 18.7 FPs/scan at 90% sensitivity, and 7.8 FPs/scan at 80% sensitivity. (orig.)

  12. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University Hospital, Daegu (Korea, Republic of); Seo, Ji Hyoung [Inje University Haeundae Paik Hospital, Busan (Korea, Republic of)

    2010-12-15

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  13. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae; Seo, Ji Hyoung

    2010-01-01

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  14. Robust Correlation Analyses: False Positive and Power Validation Using a New Open Source Matlab Toolbox

    Science.gov (United States)

    Pernet, Cyril R.; Wilcox, Rand; Rousselet, Guillaume A.

    2012-01-01

    Pearson’s correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab(R) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand. PMID:23335907

  15. Robust correlation analyses: false positive and power validation using a new open source matlab toolbox.

    Science.gov (United States)

    Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A

    2012-01-01

    Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.

  16. Prona positioning in patients submitted to myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Cunha, C.J.; Ferreira, F.C.L.; Dullius, M.A.; Souza, S.O.; Souza, D.N.

    2011-01-01

    The myocardium perfusion scintigraphy corresponds at the nuclear medicine to one of best diagnostic methods for myocardium diseases. However, artefacts generated by the diaphragmatic tissue can induce to false positive diagnostic when does not occurs association of the image in supine position with the prone position. Images acquired at the two positions were analysed and the evaluation of tomographic images were estimation and consequently, a more completed diagnostic

  17. Dual isotope, single acquisition parathyroid imaging

    International Nuclear Information System (INIS)

    Triantafillou, M.; McDonald, H.J.

    1998-01-01

    Full text: Nuclear Medicine parathyroid imaging using Thallium-201(TI) and Technetium-99m(Tc) is an often used imaging modality for the detection of parathyroid adenomas and hyper parathyroidism. The conventional Tl/Tc subtraction technique requires 2 separate injections and acquisitions which are then normalised and subtracted from each other. This lengthy technique is uncomfortable for patients and can result in false positive scan results due to patient movement between and during the acquisition process. We propose a simplified injection and single acquisition technique, that reduces the chance of movement and thus reduces the chance of false positive scan results. The technique involves the injection of Tc followed by the Tl injection 10 minutes later. After a further 10 min wait, imaging is performed using a dual isotope acquisition, with window (W) 1 set on 140 keV 20%W 5% off peak and W2 peaked for 70 keV 20%W., acquired for 10 minutes. We have imaged 27 patients with this technique, 15 had positive parathyroid imaging. Of the 15, 11 had positive ultrasound correlation. Of the remaining 4, 2 have had positive surgical findings for adenomas, the other 2 are awaiting follow-up. Of the 12 patients with negative parathyroid imaging, 2 have been shown to be false - negative with surgery. In conclusion, the single acquisition technique suggested by us is a valid method of imaging parathyroids that reduces the chance of false positive results due to movement

  18. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  19. With sadness comes accuracy; with happiness, false memory: mood and the false memory effect.

    Science.gov (United States)

    Storbeck, Justin; Clore, Gerald L

    2005-10-01

    The Deese-Roediger-McDermott paradigm lures people to produce false memories. Two experiments examined whether induced positive or negative moods would influence this false memory effect. The affect-as-information hypothesis predicts that, on the one hand, positive affective cues experienced as task-relevant feedback encourage relational processing during encoding, which should enhance false memory effects. On the other hand, negative affective cues are hypothesized to encourage item-specific processing at encoding, which should discourage such effects. The results of Experiment 1 are consistent with these predictions: Individuals in negative moods were significantly less likely to show false memory effects than those in positive moods or those whose mood was not manipulated. Experiment 2 introduced inclusion instructions to investigate whether moods had their effects at encoding or retrieval. The results replicated the false memory finding of Experiment 1 and provide evidence that moods influence the accessibility of lures at encoding, rather than influencing monitoring at retrieval of whether lures were actually presented.

  20. Evidence for subwavelength imaging with positive refraction

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yun Gui [Temasek Laboratories, National University of Singapore, Singapore 119260 (Singapore); Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom); Ong, C K, E-mail: ulf@st-andrews.ac.uk [Centre for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, Singapore 117542 (Singapore)

    2011-03-15

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  1. Evidence for subwavelength imaging with positive refraction

    International Nuclear Information System (INIS)

    Ma, Yun Gui; Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf; Ong, C K

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  2. Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study

    International Nuclear Information System (INIS)

    Vigneault, Eric; Pouliot, Jean; Laverdiere, Jacques; Roy, Jean; Dorion, Marc

    1997-01-01

    Purpose: This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. Methods and Materials: Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transcrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker. Results: We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under

  3. Proportion of false-positive lesions at interim and end-of-treatment FDG-PET in lymphoma as determined by histology: Systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com; Kwee, Thomas C.

    2016-11-15

    Purpose: To systematically review and meta-analyze the proportion of false-positive lesions at interim and end-of-treatment {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in lymphoma using biopsy as reference standard. Materials and methods: Medline was searched for original studies. Methodological quality of included studies was evaluated, and results were meta-analytically summarized using random effects (in case of interstudy heterogeneity [I{sup 2} ≤ 50%]) or fixed effects (in case of no interstudy heterogeneity [I{sup 2} > 50%]). Results: Eleven studies, comprising 139 patients who underwent biopsy of an FDG-avid lesion during or after completion of antilymphoma treatment, were included. Overall methodological quality was moderate. The proportion of false-positive results among all biopsied FDG-avid lesions at PET performed during of after completion of treatment ranged between 7.7% and 90.5% (the vast majority was due to inflammatory changes), with a weighted summary proportion (random effects, I{sup 2} = 75.7%) of 55.7% (95% confidence interval [CI]: 32.6–76.6%). There were no available studies on interim FDG-PET in Hodgkin lymphoma. The pooled summary false-positive proportions were 83.0% (95% CI: 72.0%–90.2%) for interim FDG-PET in non-Hodgkin lymphoma (fixed effects, I{sup 2} = 27.7%), 23.1% (95% CI: 4.7%–64.5%) for end-of-treatment FDG-PET in Hodgkin lymphoma (random effects; I{sup 2} = 67.1%), and 31.5% (95% CI: 3.9%–83.9%) for end-of-treatment FDG-PET in non-Hodgkin lymphoma (random effects, I{sup 2} = 68.3%). Conclusion: Both interim and end-of-treatment FDG-PET scans in patients with lymphoma suffer from a very high number of false-positive FDG-avid lesions. This finding, in combination with the previously reported high number of false-negative FGD-PET scans for residual disease detection, suggests that the role of interim and end-of-treatment FDG-PET should be reconsidered.

  4. Predictors and health-related outcomes of positive body image in adolescent girls: A prospective study.

    Science.gov (United States)

    Andrew, Rachel; Tiggemann, Marika; Clark, Levina

    2016-03-01

    This study aimed to investigate prospective predictors and health-related outcomes of positive body image in adolescent girls. In so doing, the modified acceptance model of intuitive eating was also examined longitudinally. A sample of 298 girls aged 12 to 16 years completed a questionnaire containing measures of body appreciation, potential predictors, and a range of health outcomes, at 2 time points separated by 1 year. Longitudinal change regression models showed that perceived body acceptance by others (positively), self-objectification and social comparison (negatively), and body appreciation (positively) prospectively predicted intuitive eating 1 year later, consistent with the acceptance model of intuitive eating. Perceived body acceptance by others was the only proposed predictor to prospectively predict an increase in body appreciation over time. Time 1 body appreciation prospectively predicted a decrease in dieting, alcohol, and cigarette use, and an increase in physical activity 1 year later. In particular, girls with low body appreciation were more likely than girls with high body appreciation to take up alcohol and cigarette use between time points. The results highlight body appreciation as an important target for interventions designed to prevent or delay the uptake of alcohol and cigarette consumption among girls. More broadly, they suggest that a positive body image can confer considerable benefit for adolescent girls. (c) 2016 APA, all rights reserved).

  5. Application of position-sensitive detectors to positron imaging

    International Nuclear Information System (INIS)

    Yamashita, Takaji; Uchida, Hiroshi; Watanabe, Mitsuo; Omura, Tomohide

    1994-01-01

    Positron imaging including positron emission tomography (PET) is expected to be a promising tool for basic and clinical research, because it makes possible the study of regional chemistry within multiple organs of the body in living human beings and experimental animals. New schemes of high resolution block detectors have been developed to improve the performance of positron imaging systems, which employ small segments of bismuth germanate (BGO) arrays and position-sensitive photomultiplier tubes (PS-PMT). The coincidence detector resolution of less than 2.0 mm in full width at half maximum was achieved with the detectors, which is very close to the theoretical resolution limit in positron imaging. (author)

  6. Effects of depressive disorder on false memory for emotional information.

    Science.gov (United States)

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  7. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    International Nuclear Information System (INIS)

    Ascunce, Nieves; Ederra, Maria; Delfrade, Josu; Erdozain, Nieves; Baroja, Araceli; Zubizarreta, Raquel; Salas, Dolores; Castells, Xavier

    2012-01-01

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  8. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    Energy Technology Data Exchange (ETDEWEB)

    Ascunce, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Instituto de Salud Publica, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Ederra, Maria; Delfrade, Josu; Erdozain, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Baroja, Araceli [Fundacion Rioja Salud, Logrono (Spain); Zubizarreta, Raquel [Public Health and Planning Directorate, Health Office, Galician Breast Cancer Screening Programme, Galicia (Spain); Salas, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Castells, Xavier [Mar Teaching Hospital, CIBERESP, Department of Clinical Epidemiology, Barcelona (Spain)

    2012-02-15

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  9. Evidence for subwavelength imaging with positive refraction

    OpenAIRE

    Ma, Yun Gui; Sahebdivan, Sahar; Ong, C. K.; Tyc, Tomas; Leonhardt, Ulf

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction. Publisher PDF Peer reviewed

  10. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  11. False Color Image of Volcano Sapas Mons

    Science.gov (United States)

    1991-01-01

    This false-color image shows the volcano Sapas Mons, which is located in the broad equatorial rise called Atla Regio (8 degrees north latitude and 188 degrees east longitude). The area shown is approximately 650 kilometers (404 miles) on a side. Sapas Mons measures about 400 kilometers (248 miles) across and 1.5 kilometers (0.9 mile) high. Its flanks show numerous overlapping lava flows. The dark flows on the lower right are thought to be smoother than the brighter ones near the central part of the volcano. Many of the flows appear to have been erupted along the flanks of the volcano rather than from the summit. This type of flank eruption is common on large volcanoes on Earth, such as the Hawaiian volcanoes. The summit area has two flat-topped mesas, whose smooth tops give a relatively dark appearance in the radar image. Also seen near the summit are groups of pits, some as large as one kilometer (0.6 mile) across. These are thought to have formed when underground chambers of magma were drained through other subsurface tubes and lead to a collapse at the surface. A 20 kilometer-diameter (12-mile diameter) impact crater northeast of the volcano is partially buried by the lava flows. Little was known about Atla Regio prior to Magellan. The new data, acquired in February 1991, show the region to be composed of at least five large volcanoes such as Sapas Mons, which are commonly linked by complex systems of fractures or rift zones. If comparable to similar features on Earth, Atla Regio probably formed when large volumes of molten rock upwelled from areas within the interior of Venus known as'hot spots.' Magellan is a NASA spacecraft mission to map the surface of Venus with imaging radar. The basic scientific instrument is a synthetic aperture radar, or SAR, which can look through the thick clouds perpetually shielding the surface of Venus. Magellan is in orbit around Venus which completes one turn around its axis in 243 Earth days. That period of time, one Venus day

  12. Cerebral perfusion imaging in HIV positive patients

    International Nuclear Information System (INIS)

    Kundley, Kshama; Chowdhury, D.; Lele, V.R.; Lele, R.D.

    1998-01-01

    Full text: Twelve human immunodeficiency virus (HIV) positive patients were studied by SPECT cerebral perfusion imaging 1 hour post injection of 15 mCi of 99m Tc-ECD under ideal conditions with a triple head gamma camera (Prism 3000 X P LEUHR), fanbeam collimators followed by Folstein Mini Mental Status Examination (FMMSE) and AIDS dementia complex (ADC) staging on the same day. All 12 patients were male, in the age range of 23-45 y (mean 31 y). The infected status was diagnosed by ELISA (10 patients) or Western blot (5 patients). The interval between diagnosis and imaging ranged from 1 month - 35 months (mean 15.3 months). Two patients were alcoholic and 2 were smokers. None of them had CNS disorder clinically. ADC staging and FMMSE could be performed in 4 patients. Two patients were normal (stage 0) and 2 were subclinical (stage 0.5) on ADC staging. FMMSE revealed normal or near normal status (mean score 35; maximum score 36). Cerebral perfusion images were interpreted simultaneously by 3 observers blind towards history and examination using semi-quantitative and quantitative methods by consensus. It revealed multiple areas of hypoperfusion, viz. temporal (11 patients (91 %), parietal 10 patients (83%), frontal 9 patients (75%, pre and post central gyrus 7 patients (58%), occipital 6 patients (50%) cingulate gyrus and cerebellum 5 patients (41%) and thalamic in 2 patients (16%). Hyper perfusion in caudate nuclei was noted in 10 patients (83%). The study reveals presence of multiple perfusion abnormalities on cerebral perfusion imaging in HIV positive patients who have normal/near normal mental status suggesting precedence of perfusion abnormality over clinically apparent mental deficit

  13. An accurate test for acute appendicitis: In-111 WBC imaging

    International Nuclear Information System (INIS)

    Navarro, D.A.; Weber, P.M.; Kang, I.Y.; dosRemedios, L.V.; Jasko, I.A.

    1985-01-01

    The decision to operate when acute appendicitis (APPY) is suspected is often difficult. Surgeons accept up to a 20% false positive rate to avoid any delay that may result in appendiceal rupture and peritonitis. The authors have successfully improved early diagnostic accuracy by using abdominal imaging beginning 2 hours after injecting In-111 labeled WBC. Patients with clear-cut (APPY) had laparotomy and were not studied. Those who were to be observed in the ER for possible (APPY) had their leukocytes harvested, labeled with In-111 oxine, and reinjected. Abnormal localized activity in the right lower quadrant (RLQ) imaged at 2 hours was graded relative to bone marrow activity (8M): 0, 1+ BM. When available the surgical specimen was imaged for In-111 activity. Of 31 patients studied there were 13 with positive scans for (APPY) all surgically confirmed. There were 4 additional abnormal studies all demonstrating known diagnostic patterns, 2 of pertonitis and 2 of colitis. There were 14 negative studies in 8 of whom the clinical course was benign; the remaining 6 had laparotomy with 3 having (APPY) and 3 not. Thus there were no false positives and 3 false negatives. One case negative at 2 hours had appendiceal activity later. The 3 cases with 3+ activity all had apendiceal abscesses. This new application of In-111 oxine WBC imaging is safe, simple, sensitive and specific. It shortens the time to surgical intervention and should reduce the surgical false positive rate

  14. Performance of a video-image-subtraction-based patient positioning system

    International Nuclear Information System (INIS)

    Milliken, Barrett D.; Rubin, Steven J.; Hamilton, Russell J.; Johnson, L. Scott; Chen, George T.Y.

    1997-01-01

    Purpose: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. Methods and Materials: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. Results: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition

  15. IS HCI THAT IS USED AS A PRESERVATIVE CREATING FALSE POSITIVES FOR TBA IN GROUND WATER

    Science.gov (United States)

    Will hydrochloric acid produce false positives for TBA? Yes, if you heat the sample to get a lower detection limit for TBA. Conventional purge and trap methods at ambient temperature have a reporting limit for TBA between 50 and 100 g/liter. This is higher than the provisiona...

  16. Empirical methods for controlling false positives and estimating confidence in ChIP-Seq peaks

    Directory of Open Access Journals (Sweden)

    Courdy Samir J

    2008-12-01

    Full Text Available Abstract Background High throughput signature sequencing holds many promises, one of which is the ready identification of in vivo transcription factor binding sites, histone modifications, changes in chromatin structure and patterns of DNA methylation across entire genomes. In these experiments, chromatin immunoprecipitation is used to enrich for particular DNA sequences of interest and signature sequencing is used to map the regions to the genome (ChIP-Seq. Elucidation of these sites of DNA-protein binding/modification are proving instrumental in reconstructing networks of gene regulation and chromatin remodelling that direct development, response to cellular perturbation, and neoplastic transformation. Results Here we present a package of algorithms and software that makes use of control input data to reduce false positives and estimate confidence in ChIP-Seq peaks. Several different methods were compared using two simulated spike-in datasets. Use of control input data and a normalized difference score were found to more than double the recovery of ChIP-Seq peaks at a 5% false discovery rate (FDR. Moreover, both a binomial p-value/q-value and an empirical FDR were found to predict the true FDR within 2–3 fold and are more reliable estimators of confidence than a global Poisson p-value. These methods were then used to reanalyze Johnson et al.'s neuron-restrictive silencer factor (NRSF ChIP-Seq data without relying on extensive qPCR validated NRSF sites and the presence of NRSF binding motifs for setting thresholds. Conclusion The methods developed and tested here show considerable promise for reducing false positives and estimating confidence in ChIP-Seq data without any prior knowledge of the chIP target. They are part of a larger open source package freely available from http://useq.sourceforge.net/.

  17. False positive results occurring in a radioimmunoassay for hepatitis A IgM antibody of the IgM class

    Energy Technology Data Exchange (ETDEWEB)

    Bucens, M R; Pietroboni, G R; Harnett, G B [Virus Lab., Combined Microbiology Service, Queen Elizabeth II Medical Centre, Perth, Western Australia

    1983-12-01

    The diagnosis of hepatitis A infection is usually based on the presence of hepatitis A specific IgM in a single serum sample. The fortuitous observation in one patient that this reactivity was apparently still present 19 mth after her original illness led to the discovery that the ABBOTT HAVAB-M kit method may produce false positive results. A series of patients who had previously had hepatitis A was retested and false positive results were found in 6% of this group. Control groups consisted of patients with other acute and chronic liver disorders and other acute viral diseases. No reactivity was detected in the control sera. Sucrose gradient fractionation revealed that the factor responsible for the false positive results was associated only with serum fractions containing IgA and IgG and that it could be removed by absorption of sera with staphylococcal protein A but not by absorption with streptococcus AR1 or by 2-mercaptoethanol treatment. It was concluded that following hepatitis A infection some patients produce a rheumatoid factor-like substance (not of IgM class) which is cleared from the serum in 2-3 yr. The presence of this factor may lead to a misdiagnosis in patients presenting with jaundice.

  18. False memories for affective information in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Beth Fairfield

    2016-11-01

    Full Text Available Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the-to-be-remembered material and false memory occurrence has not yet been studied. In this study, twenty-four patients and twenty-four healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p0.05 resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e. neutral episodes yielded a higher degree of errors than positive and negative episodes. Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  19. Occurrence of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae isolates.

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Adequate detection of the production of carbapenemase in Enterobacteriaceae isolates is crucial for infection control measures and the appropriate choice of antimicrobial therapy. In this study, we investigated the frequency of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae clinical isolates by the modified Hodge test (MHT. Three hundred and one E. coli and K. pneumoniae clinical isolates were investigated. All produced extended spectrum β-lactamases (ESBLs but were susceptible to carbapenems. Antimicrobial susceptibility testing was performed by the disk diffusion and agar dilution methods. The MHT was performed using the standard inoculum of test organisms recommended by the CLSI. Genes that encoded ESBLs and carbapenemases were identified by PCR and DNA sequencing. Among the 301 clinical isolates, none of the isolates conformed to the criteria for carbapenemase screening recommended by the CLSI. The susceptibility rates for imipenem, meropenem, and ertapenem all were 100.0%, 100.0%, and 100.0%, respectively. Of the 301 E. coli and K. pneumoniae isolates, none produced carbapenemase. The MHT gave a positive result for 3.3% (10/301 of the isolates. False positive results can occur when the MHT is used to detect carbapenemase in ESBL-producing isolates and clinical laboratories must be aware of this fact.

  20. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  1. Education for a positive self-image in a contemporary school

    Directory of Open Access Journals (Sweden)

    SANJA SIMEL

    2013-09-01

    Full Text Available In today's world characterized by changed systems of values and materialism, pedagogy should emphasize education for a positive self-image, especially in the contemporary school, whose educational goals are freedom, independence and individuality. This theoretical analysis provides a review of research on the importance and relationship of a positive self-image with other factors, such as social skills and academic achievement. Simultaneously, the methods and procedures by which teachers can foster a student's positive self-image are displayed. Although the degree of positive self-thinking is for the most part formed in interaction with other people, it is extremely important to raise students' awareness about their own internal strengths as well as their possibility of choice. The education of a positive self-image can be considered a part of "positive pedagogy" or "positive education" which focuses on traditional skills and happiness, but also joy - fervor that accompanies being (Fromm, 2004, p. 130.

  2. Images of the Self and Self-Esteem: Do Positive Self-Images Improve Self-Esteem in Social Anxiety?

    Science.gov (United States)

    Hulme, Natalie; Hirsch, Colette; Stopa, Lusia

    2012-01-01

    Negative self-images play an important role in maintaining social anxiety disorder. We propose that these images represent the working self in a Self-Memory System that regulates retrieval of self-relevant information in particular situations. Self-esteem, one aspect of the working self, comprises explicit (conscious) and implicit (automatic) components. Implicit self-esteem reflects an automatic evaluative bias towards the self that is normally positive, but is reduced in socially anxious individuals. Forty-four high and 44 low socially anxious participants generated either a positive or a negative self-image and then completed measures of implicit and explicit self-esteem. Participants who held a negative self-image in mind reported lower implicit and explicit positive self-esteem, and higher explicit negative self-esteem than participants holding a positive image in mind, irrespective of social anxiety group. We then tested whether positive self-images protected high and low socially anxious individuals equally well against the threat to explicit self-esteem posed by social exclusion in a virtual ball toss game (Cyberball). We failed to find a predicted interaction between social anxiety and image condition. Instead, all participants holding positive self-images reported higher levels of explicit self-esteem after Cyberball than those holding negative self-images. Deliberate retrieval of positive self-images appears to facilitate access to a healthy positive implicit bias, as well as improving explicit self-esteem, whereas deliberate retrieval of negative self-images does the opposite. This is consistent with the idea that negative self-images may have a causal, as well as a maintaining, role in social anxiety disorder. PMID:22439697

  3. Imaging study of brain damage from methanol intoxication of wine

    International Nuclear Information System (INIS)

    Yu Chengfu; Liu Yimin; Yang Yi; Shi Jing; Wu Yihang; Zhang Weisen; Mao Xiaofen; Luo Jing

    2006-01-01

    Objective: To investigate the imaging of CT and MRI in brain damage caused by methanol intoxication from false wine, and to study the relations between imaging manifestation and different degrees of the methanol intoxication. Method: Thirty nine cases with methanol intoxication from false wine were retrospectively reported, The latent period of these patients was 0-4 days, and the average latent period of these patients was 0.5 days, All cases were performed by serology examination, brain CT scan, and four cases performed by MRI scan after average 2.5 days (range, 1-6 days) the onset of methanol intoxication. Results: Six cases showed hyperintense signals in bilateral putamen, two cases also showed hyperintense signals in biolateral subcortex white substance regions. Four cases showed hyperintense signals in unilateral internal capsule. One case showed hyperintense changess in subcortex white substance regions. Our study showed the positive correlation between CT features and the amount of methanol and stage of clinic manifestation(χ 2 =4.232, P 2 =0.001, P>0.05). Conclusions: MRI was better than CT in finding early brain damage caused by methanol intoxication from false wine. The characteristic finding changes of the patients was showed mainly in in bilateral putamen, Prognosis for the patients combined with subcortex white substance lesion wasn't hopeful. (authors)

  4. PET imaging for the quantification of biologically heterogeneous tumours: measuring the effect of relative position on image-based quantification of dose-painting targets

    International Nuclear Information System (INIS)

    McCall, Keisha C; Barbee, David L; Kissick, Michael W; Jeraj, Robert

    2010-01-01

    Quantitative imaging of tumours represents the foundation of customized therapies and adaptive patient care. As such, we have investigated the effect of patient positioning errors on the reproducibility of images of biologically heterogeneous tumours generated by a clinical PET/CT system. A commercial multi-slice PET/CT system was used to acquire 2D and 3D PET images of a phantom containing multiple spheres of known volumes and known radioactivity concentrations and suspended in an aqueous medium. The spheres served as surrogates for sub-tumour regions of biological heterogeneities with dimensions of 5-15 mm. Between image acquisitions, a motorized-arm was used to reposition the spheres in 1 mm intervals along either the radial or the axial direction. Images of the phantom were reconstructed using typical diagnostic reconstruction techniques, and these images were analysed to characterize and model the position-dependent changes in contrast recovery. A simulation study was also conducted to investigate the effect of patient position on the reproducibility of PET imaging of biologically heterogeneous head and neck (HN) tumours. For this simulation study, we calculated the changes in image intensity values that would occur with changes in the relative position of the patients at the time of imaging. PET images of two HN patients were used to simulate an imaging study that incorporated set-up errors that are typical for HN patients. One thousand randomized positioning errors were investigated for each patient. As a result of the phantom study, a position-dependent trend was identified for measurements of contrast recovery of small objects. The peak contrast recovery occurred at radial and axial positions that coincide with the centre of the image voxel. Conversely, the minimum contrast recovery occurred when the object was positioned at the edges of the image voxel. Changing the position of high contrast spheres by one-half the voxel dimension lead to errors in the

  5. Breast cancer risk is increased in the years following false-positive breast cancer screening.

    Science.gov (United States)

    Goossens, Mathijs C; De Brabander, Isabel; De Greve, Jacques; Vaes, Evelien; Van Ongeval, Chantal; Van Herck, Koen; Kellen, Eliane

    2017-09-01

    A small number of studies have investigated breast cancer (BC) risk among women with a history of false-positive recall (FPR) in BC screening, but none of them has used time-to-event analysis while at the same time quantifying the effect of false-negative diagnostic assessment (FNDA). FNDA occurs when screening detects BC, but this BC is missed on diagnostic assessment (DA). As a result of FNDA, screenings that detected cancer are incorrectly classified as FPR. Our study linked data recorded in the Flemish BC screening program (women aged 50-69 years) to data from the national cancer registry. We used Cox proportional hazards models on a retrospective cohort of 298 738 women to assess the association between FPR and subsequent BC, while adjusting for potential confounders. The mean follow-up was 6.9 years. Compared with women without recall, women with a history of FPR were at an increased risk of developing BC [hazard ratio=2.10 (95% confidence interval: 1.92-2.31)]. However, 22% of BC after FPR was due to FNDA. The hazard ratio dropped to 1.69 (95% confidence interval: 1.52-1.87) when FNDA was excluded. Women with FPR have a subsequently increased BC risk compared with women without recall. The risk is higher for women who have a FPR BI-RADS 4 or 5 compared with FPR BI-RADS 3. There is room for improvement of diagnostic assessment: 41% of the excess risk is explained by FNDA after baseline screening.

  6. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  7. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Science.gov (United States)

    Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung

    2017-01-01

    To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  8. Associations Between Positive Body Image, Sexual Liberalism, and Unconventional Sexual Practices in U.S. Adults.

    Science.gov (United States)

    Swami, Viren; Weis, Laura; Barron, David; Furnham, Adrian

    2017-11-01

    While studies have documented robust relationships between body image and sexual health outcomes, few studies have looked beyond sexual functioning in women. Here, we hypothesized that more positive body image would be associated with greater sexual liberalism and more positive attitudes toward unconventional sexual practices. An online sample of 151 women and 164 men from the U.S. completed measures of sexual liberalism, attitudes toward unconventional sexual practices, and indices of positive body image (i.e., body appreciation, body acceptance by others, body image flexibility, and body pride), and provided their demographic details. Regression analyses indicated that, once the effects of sexual orientation, relationship status, age, and body mass index had been accounted for, higher body appreciation was significantly associated with greater sexual liberalism in women and men. Furthermore, higher body appreciation and body image flexibility were significantly associated with more positive attitudes toward unconventional sexual practices in women and men. These results may have implications for scholars working from a sex-positive perspective, particularly in terms of understanding the role body image plays in sexual attitudes and behaviors.

  9. Processing of false belief passages during natural story comprehension: An fMRI study.

    Science.gov (United States)

    Kandylaki, Katerina D; Nagels, Arne; Tune, Sarah; Wiese, Richard; Bornkessel-Schlesewsky, Ina; Kircher, Tilo

    2015-11-01

    The neural correlates of theory of mind (ToM) are typically studied using paradigms which require participants to draw explicit, task-related inferences (e.g., in the false belief task). In a natural setup, such as listening to stories, false belief mentalizing occurs incidentally as part of narrative processing. In our experiment, participants listened to auditorily presented stories with false belief passages (implicit false belief processing) and immediately after each story answered comprehension questions (explicit false belief processing), while neural responses were measured with functional magnetic resonance imaging (fMRI). All stories included (among other situations) one false belief condition and one closely matched control condition. For the implicit ToM processing, we modeled the hemodynamic response during the false belief passages in the story and compared it to the hemodynamic response during the closely matched control passages. For implicit mentalizing, we found activation in typical ToM processing regions, that is the angular gyrus (AG), superior medial frontal gyrus (SmFG), precuneus (PCUN), middle temporal gyrus (MTG) as well as in the inferior frontal gyrus (IFG) billaterally. For explicit ToM, we only found AG activation. The conjunction analysis highlighted the left AG and MTG as well as the bilateral IFG as overlapping ToM processing regions for both implicit and explicit modes. Implicit ToM processing during listening to false belief passages, recruits the left SmFG and billateral PCUN in addition to the "mentalizing network" known form explicit processing tasks. © 2015 Wiley Periodicals, Inc.

  10. Psychoactive drugs and false memory: comparison of dextroamphetamine and delta-9-tetrahydrocannabinol on false recognition

    Science.gov (United States)

    Ballard, Michael E.; Gallo, David A.; de Wit, Harriet

    2014-01-01

    Rationale Several psychoactive drugs are known to influence episodic memory. However, these drugs’ effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Objectives Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ9-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger–McDermott (DRM) illusion. Methods Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. Results As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs’ effects on true memory were positively correlated with their effects on false memory. Conclusions Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories. PMID:21647577

  11. Psychoactive drugs and false memory: comparison of dextroamphetamine and δ-9-tetrahydrocannabinol on false recognition.

    Science.gov (United States)

    Ballard, Michael E; Gallo, David A; de Wit, Harriet

    2012-01-01

    Several psychoactive drugs are known to influence episodic memory. However, these drugs' effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ(9)-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger-McDermott (DRM) illusion. Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs' effects on true memory were positively correlated with their effects on false memory. Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories.

  12. Enough positive rate of paraspinal mapping and diffusion tensor imaging with levels which should be decompressed in lumbar spinal stenosis.

    Science.gov (United States)

    Chen, Hua-Biao; Zhong, Zhi-Wei; Li, Chun-Sheng; Bai, Bo

    2016-07-01

    In lumbar spinal stenosis, correlating symptoms and physical examination findings with decompression levels based on common imaging is not reliable. Paraspinal mapping (PM) and diffusion tensor imaging (DTI) may be possible to prevent the false positive occurrences with MRI and show clear benefits to reduce the decompression levels of lumbar spinal stenosis than conventional magnetic resonance imaging (MRI) + neurogenic examination (NE). However, they must have enough positive rate with levels which should be decompressed at first. The study aimed to confirm that the positive of DTI and PM is enough in levels which should be decompressed in lumbar spinal stenosis. The study analyzed the positive of DTI and PM as well as compared the preoperation scores to the postoperation scores, which were assessed preoperatively and at 2 weeks, 3 months 6 months, and 12 months postoperatively. 96 patients underwent the single level decompression surgery. The positive rate among PM, DTI, and (PM or DTI) was 76%, 98%, 100%, respectively. All post-operative Oswestry Disability Index (ODI), visual analog scale for back pain (VAS-BP) and visual analog scale for leg pain (VAS-LP) scores at 2 weeks postoperatively were measured improvement than the preoperative ODI, VAS-BP and VAS-LP scores with statistically significance (p-value = 0.000, p-value = 0.000, p-value = 0.000, respectively). In degenetive lumbar spinal stenosis, the positive rate of (DTI or PM) is enough in levels which should be decompressed, thence using the PM and DTI to determine decompression levels will not miss the level which should be operated. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  13. Study of positioning techniques for radiography

    International Nuclear Information System (INIS)

    Maruyama, Toshinori; Yamamoto, Hideki

    2008-01-01

    A good positioning technique is of great importance in radiology in order to obtain accurate diagnostic information and reduce the patient's X-ray exposure. In positioning training, students place the phantom on the table under an X-ray tube, adjust the position of the phantom, and repeat the positioning practices until they can obtain fine diagnostic images. As X-ray films are usually used in radiography, the development of such films is necessary. In this kind of training practice, it takes a great deal of time to obtain the X-ray image at the phantom position. It is desirable for students to perform positioning accurately and to confirm the results of positioning within a short time. In this article, we propose a new positioning training method using digital image processing. First, we scan the skull phantom by CT (computed tomography) and obtain CT images. Next, we measure the positioning information of the phantom under the X-ray equipment by using scene analysis. Then, we develop a method that produces the plane image corresponding to the detected phantom position under the X-ray tube. It is expected that our method will be useful as a teaching device to help in the practice of the positioning techniques for various organs without X-ray exposure and, furthermore, in the development of X-ray films. (author)

  14. The Institution Image and Trust and Their Effect on the Positive Word of Mouth

    Directory of Open Access Journals (Sweden)

    Soni Harsono

    2014-04-01

    Full Text Available In marketing, it is important to see how competitive a university is. Among public universities (PTN and private universities (PTS, it shows a very competitive situation recently. To overcome this problem, it requires shaping up the institution image and trust for increasing the positive word of mouth among students. This study aims to determine the effect of the institution image, trust both partially and simultaneously on the positive word of mouth by the students of private universities in Surabaya with their accreditation levels of A, B and C. The sample consists of students from six colleges with accreditation ratings A, B, and C totaling 125 students. Accidental sampling technique was done using a sampling technique of multiple regression analysis with SPSS version 17. It shows, for the college with accreditation category C, the image of the institution both partially and simulta-neously has significant positive effect on the positive word of mouth. For the college accreditation category B, the image of the institution and trust simultaneously has significant positive effect on the positive word of mouth and, finally, trust in accreditation category A has significant positive effect on the positive word of mouth and the institution image and trust simultaneously have significant positive effect on the positive word of mouth.

  15. False-positive positron emission tomography appearance with 18F-fluorodeoxyglucose after definitive radiotherapy for cancer of the mobile tongue.

    Science.gov (United States)

    Ariji, Y; Fuwa, N; Kodaira, T; Tachibana, H; Nakamura, T; Satoh, Y; Ariji, E

    2009-01-01

    (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is an effective tool for evaluating the results of radiotherapy. However, some false-positive appearances caused by physiological or pathological accumulation are reported. We report on three patients who showed a high accumulation of FDG in the lingual muscles but had no recurrent tumour after definitive radiotherapy for the mobile tongue. All patients had squamous cell carcinoma of the tongue and received interstitial radiotherapy with small sources. High uptake was seen in the lingual muscles without recurrence or inflammation, based on physical and MR examinations. This false-positive appearance is thought to relate to ill-balanced high activity of the lingual muscles after definitive radiotherapy.

  16. Emotions and false memories: valence or arousal?

    Science.gov (United States)

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  17. False-positive image of portal thrombosis with MRI: portal hypertension as a pitfall. Observation in a Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Davy-Miallou, C.; Bousquet, J.C.; Bellin, M.F.; Guinet, C.; Grellet, J.

    1990-01-01

    This observation illustrates how difficult it is to interpret the intravascular signal observed with MRI in cases of portal hypertension. A signal occupying the entire lumen of the portal trunk and branches can be seen, which is constantly observed in the axial as well as coronal planes in the 3 series studied. It is hypointense relative to the liver on T1-weighted images, hyperintense on T2-weighted images: this appearance therefore perfectly mimicks portal thrombosis. Ultrasound combined with pulsed Doppler demonstrates the stagnant blood within the patent portal system. This kind of artifact, which is produced by a very slow flow or even by the standstill of flow, is much more difficult to recognize than the common flow artifacts; the criteria put forward by various authors to distinguish between artifacts and thrombosis are of no avail in this case. Examinations must able to confirm or rule out portal thrombosis in the case of portal hypertension with deceleration of flow. In practice, ultrasound studies, combined with pulsed Doppler in the best cases, is therefore indicated as a first-intension technique [fr

  18. Placing symptoms in context: the role of contextual criteria in reducing false positives in Diagnostic and Statistical Manual of Mental Disorders diagnoses.

    Science.gov (United States)

    Wakefield, Jerome C; First, Michael B

    2012-02-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Event-related fMRI studies of false memory: An Activation Likelihood Estimation meta-analysis.

    Science.gov (United States)

    Kurkela, Kyle A; Dennis, Nancy A

    2016-01-29

    Over the last two decades, a wealth of research in the domain of episodic memory has focused on understanding the neural correlates mediating false memories, or memories for events that never happened. While several recent qualitative reviews have attempted to synthesize this literature, methodological differences amongst the empirical studies and a focus on only a sub-set of the findings has limited broader conclusions regarding the neural mechanisms underlying false memories. The current study performed a voxel-wise quantitative meta-analysis using activation likelihood estimation to investigate commonalities within the functional magnetic resonance imaging (fMRI) literature studying false memory. The results were broken down by memory phase (encoding, retrieval), as well as sub-analyses looking at differences in baseline (hit, correct rejection), memoranda (verbal, semantic), and experimental paradigm (e.g., semantic relatedness and perceptual relatedness) within retrieval. Concordance maps identified significant overlap across studies for each analysis. Several regions were identified in the general false retrieval analysis as well as multiple sub-analyses, indicating their ubiquitous, yet critical role in false retrieval (medial superior frontal gyrus, left precentral gyrus, left inferior parietal cortex). Additionally, several regions showed baseline- and paradigm-specific effects (hit/perceptual relatedness: inferior and middle occipital gyrus; CRs: bilateral inferior parietal cortex, precuneus, left caudate). With respect to encoding, analyses showed common activity in the left middle temporal gyrus and anterior cingulate cortex. No analysis identified a common cluster of activation in the medial temporal lobe. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  1. [Neuropsychological study of false memory in patients with amnesia mild cognitive impairment].

    Science.gov (United States)

    Xie, Dan-dan; Cheng, Huai-dong; Yin, Chang-lin; Lü, Xin-yi; Wang, Kai

    2011-01-18

    To explore the profile of false memory in aMCI (amnesia mild cognitive impairment) and to elucidate the neuropsychological mechanism of false memory. False memory provoked by pictures and feeling-of-knowing (FOK) test in episodic memory (EM) were conducted in 25 aMCI patients at our hospital from October 2009 to May 2010. And 25 age and education level-matched healthy patients were recruited into the healthy control (HC) group. As compared with HC group, the rate of false memory was higher in the aMCI group. The rate of false memory in recall stage was 26% ± 7% and that of questionnaire stage 28% ± 12%. And the difference between two group was significant (t = 14.437, 7.597, P false recognition in the aMCI group (41% ± 10%) was higher than the HC group. And the difference was significant (t = 4.207, P false memory in recall and questionnaire stages were positively correlated with FOK-EM in aMCI group (r = 0.563, 0.705, P false memory provoked by pictures. The deficit of memory monitoring in aMCI may be the foundation of false memory.

  2. Natural-pose hand detection in low-resolution images

    Directory of Open Access Journals (Sweden)

    Nyan Bo Bo1

    2009-07-01

    Full Text Available Robust real-time hand detection and tracking in video sequences would enable many applications in areas as diverse ashuman-computer interaction, robotics, security and surveillance, and sign language-based systems. In this paper, we introducea new approach for detecting human hands that works on single, cluttered, low-resolution images. Our prototype system, whichis primarily intended for security applications in which the images are noisy and low-resolution, is able to detect hands as smallas 2424 pixels in cluttered scenes. The system uses grayscale appearance information to classify image sub-windows as eithercontaining or not containing a human hand very rapidly at the cost of a high false positive rate. To improve on the false positiverate of the main classifier without affecting its detection rate, we introduce a post-processor system that utilizes the geometricproperties of skin color blobs. When we test our detector on a test image set containing 106 hands, 92 of those hands aredetected (86.8% detection rate, with an average false positive rate of 1.19 false positive detections per image. The rapiddetection speed, the high detection rate of 86.8%, and the low false positive rate together ensure that our system is useable asthe main detector in a diverse variety of applications requiring robust hand detection and tracking in low-resolution, clutteredscenes.

  3. False positive localisation of C-11 methionine in a colloid nodule

    International Nuclear Information System (INIS)

    Mahajan, Sonia; Tripathi, Madhavi; Jaimini, Abhinav; Dinesh, Anant

    2011-01-01

    A 45-year-old female diagnosed with carcinoma of the left breast on histopathological examination underwent both 18 F-flourodeoxyglucose (FDG) and 11C-methionine (MET) positron emission tomography/computed tomography (PET/CT) as part of a protocol comparing the utility of these tracers for predicting a response to neoadjuvant chemotherapy in breast carcinoma. Abnormal FDG and MET accumulation was noted in the left breast primary, left axillary lymph nodes, and also in a well-defined nodule present in the left lobe of the thyroid gland. Keeping in mind the possibility of thyroid neoplasm/metastasis, the patient was referred for fine needle aspiration cytology (FNAC) from the thyroid nodule that revealed features of a simple colloid nodule. Focal thyroid lesions incidentally found on 18 F-FDG PET/CT have a high risk of thyroid malignancy. Non-specific accumulation of FDG in thyroid adenomas is also known. This case highlights a potential cause for false positive on C-11 MET PET/CT in colloid adenomas, which should be kept in mind while using this tracer for oncological indications

  4. Pairing images of unhealthy and healthy foods with images of negative and positive health consequences: Impact on attitudes and food choice.

    Science.gov (United States)

    Hollands, Gareth J; Marteau, Theresa M

    2016-08-01

    To examine the impact of presenting images of foods paired with images of positive and negative health consequences of their consumption on food choice and attitudes. Participants (N = 711) were randomly allocated in a 2 × 3 factorial design (Food Type × Affective Valence) to 1 of 6 conditioning procedures that paired images of either energy-dense snack foods or fruit, with (a) images of negative health outcomes, (b) images of positive health outcomes, or (c) a no image control. The primary outcome was food choice assessed postintervention with a behavioral choice task. Secondary outcomes were implicit attitudes (assessed pre- and postintervention) and explicit attitudes (assessed postintervention). Presenting images of negative health outcomes led to more healthy food choices relative to control and positive image conditions, irrespective of whether they were paired with images of energy-dense snack foods or fruit. This relationship was partially mediated by changes in implicit and explicit attitudes. Images of positive health outcomes did not alter food choices. This study replicates and extends previous research showing that presenting images of negative health consequences increases healthy food choices. Because effects were elicited by manipulating affective valence irrespective of paired food type, these results appear more consistent with an explanation based on priming than on evaluative conditioning. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Improved detection of breast cancer on FDG-PET cancer screening using breast positioning device

    International Nuclear Information System (INIS)

    Kaida, Hayato; Ishibashi, Masatoshi; Fujii, Teruhiko; Kurata, Seiji; Ogo, Etsuyo; Hayabuchi, Naofumi; Tanaka, Maki

    2008-01-01

    The aim of this study was to investigate the detection rate of breast cancer by positron emission tomography cancer screening using a breast positioning device. Between January 2004 and January 2006, 1,498 healthy asymptomatic individuals underwent cancer screening by fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) at our institution; 660 of 1498 asymptomatic healthy women underwent breast PET imaging in the prone position using the breast positioning device to examine the mammary glands in addition to whole-body PET imaging. All subjects that showed abnormal 18 F-FDG uptake in the mammary glands were referred for further examination or surgery at our institution or a local hospital. Our data were compared with the histopathological findings or findings of other imaging modalities in our institution and replies from the doctors at another hospital. Of the 660 participants, 7 (1.06%) were found to have breast cancers at a curable stage. All the seven cancers were detected by breast PET imaging, but only five of these were detected by whole-body PET imaging; the other two were detected by breast PET imaging using the breast positioning device. In cancer screening, prone breast imaging using a positioning device may help to improve the detection rate of breast cancer. However, overall cancer including mammography and ultrasonography screening should be performed to investigate the false-negative cases and reduce false-positive cases. The effectiveness of prone breast PET imaging in cancer screening should be investigated using a much larger number of cases in the near future. (author)

  6. Comparison of bladder neck position in nulliparous and parous women using MR images in the sitting position

    International Nuclear Information System (INIS)

    Masaki, Kiyoko; Okayama, Hisayo; Tuchikawa, Sachi; Saito, Yoshino; Endo, Yoshihiro; Morikawa, Shigehiro; Ninomiya, Sanae; Saito, Izumi; Hiraiwa, Yasuyuki

    2011-01-01

    The purpose of this study was to investigate the influence of childbirth on pelvic floor relaxation in females using the bladder neck position. The position of bladder neck was examined in 17 nulligravid (19-24 years of age) and 55 parous women (35-54) using MR images in the sitting position. The position of bladder neck from pubococcygeal line was 13.4 mm (mean) in nulligravid women, and 8.5 mm in parous women (p<0.05). The bladder neck position in parous women was significantly lower than that in nulligravid women. Therefore, it was clearly shown that childbirth causes the pelvic floor relaxation. (author)

  7. Influence of image reconstruction methods on statistical parametric mapping of brain PET images

    International Nuclear Information System (INIS)

    Yin Dayi; Chen Yingmao; Yao Shulin; Shao Mingzhe; Yin Ling; Tian Jiahe; Cui Hongyan

    2007-01-01

    Objective: Statistic parametric mapping (SPM) was widely recognized as an useful tool in brain function study. The aim of this study was to investigate if imaging reconstruction algorithm of PET images could influence SPM of brain. Methods: PET imaging of whole brain was performed in six normal volunteers. Each volunteer had two scans with true and false acupuncturing. The PET scans were reconstructed using ordered subsets expectation maximization (OSEM) and filtered back projection (FBP) with 3 varied parameters respectively. The images were realigned, normalized and smoothed using SPM program. The difference between true and false acupuncture scans was tested using a matched pair t test at every voxel. Results: (1) SPM corrected multiple comparison (P corrected uncorrected <0.001): SPM derived from the images with different reconstruction method were different. The largest difference, in number and position of the activated voxels, was noticed between FBP and OSEM re- construction algorithm. Conclusions: The method of PET image reconstruction could influence the results of SPM uncorrected multiple comparison. Attention should be paid when the conclusion was drawn using SPM uncorrected multiple comparison. (authors)

  8. Imaging spectrum and pitfalls of 11C-methionine position emission tomography in a series of patients with intracranial lesions

    International Nuclear Information System (INIS)

    Ito, Kimiteru; Matsuda, Hiroshi; Kubota, Kazoo

    2016-01-01

    11 C-methionine (Met) positron emission tomography (PET) is one of the most commonly used PET tracers for evaluating brain tumors. However, few reports have described tips and pitfalls of 11 C-Met PET for general practitioners. Physiological 11 C-Met uptake, anatomical variations, vascular disorders, non-tumorous lesions such as inflammation or dysplasia, benign brain tumors and patient condition during 11 C-Met PET examination can potentially affect the image interpretation and cause false positives and negatives. These pitfalls in the interpretation of 11 C-Met PET images are important for not only nuclear medicine physicians but also general radiologists. Familiarity with the spectrum and pitfalls of 11 C-Met images could help prevent unfavorable clinical results caused by misdiagnoses

  9. Low contrast detectability for color patterns variation of display images

    International Nuclear Information System (INIS)

    Ogura, Akio

    1998-01-01

    In recent years, the radionuclide images are acquired in digital form and displayed with false colors for signal intensity. This color scales for signal intensity have various patterns. In this study, low contrast detectability was compared the performance of gray scale cording with three color scales: the hot color scale, prism color scale and stripe color scale. SPECT images of brain phantom were displayed using four color patterns. These printed images and display images were evaluated with ROC analysis. Display images were indicated higher detectability than printed images. The hot scale and gray scale images indicated better Az of ROC than prism scale images because the prism scale images showed higher false positive rate. (author)

  10. Underpowered samples, false negatives, and unconscious learning.

    Science.gov (United States)

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  11. The impact of reorienting cone-beam computed tomographic images in varied head positions on the coordinates of anatomical landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hun; Jeong, Ho Gul; Hwang, Jae Joon; Lee, Jung Hee; Han, Sang Sun [Dept. of Oral and Maxillofacial Radiology, Yonsei University, College of Dentistry, Seoul (Korea, Republic of)

    2016-06-15

    The aim of this study was to compare the coordinates of anatomical landmarks on cone-beam computed tomographic (CBCT) images in varied head positions before and after reorientation using image analysis software. CBCT images were taken in a normal position and four varied head positions using a dry skull marked with 3 points where gutta percha was fixed. In each of the five radiographic images, reference points were set, 20 anatomical landmarks were identified, and each set of coordinates was calculated. Coordinates in the images from the normally positioned head were compared with those in the images obtained from varied head positions using statistical methods. Post-reorientation coordinates calculated using a three-dimensional image analysis program were also compared to the reference coordinates. In the original images, statistically significant differences were found between coordinates in the normal-position and varied-position images. However, post-reorientation, no statistically significant differences were found between coordinates in the normal-position and varied-position images. The changes in head position impacted the coordinates of the anatomical landmarks in three-dimensional images. However, reorientation using image analysis software allowed accurate superimposition onto the reference positions.

  12. Consumer opinion on social policy approaches to promoting positive body image: Airbrushed media images and disclaimer labels.

    Science.gov (United States)

    Paraskeva, Nicole; Lewis-Smith, Helena; Diedrichs, Phillippa C

    2017-02-01

    Disclaimer labels on airbrushed media images have generated political attention and advocacy as a social policy approach to promoting positive body image. Experimental research suggests that labelling is ineffective and consumers' viewpoints have been overlooked. A mixed-method study explored British consumers' ( N = 1555, aged 11-78 years) opinions on body image and social policy approaches. Thematic analysis indicated scepticism about the effectiveness of labelling images. Quantitatively, adults, although not adolescents, reported that labelling was unlikely to improve body image. Appearance diversity in media and reorienting social norms from appearance to function and health were perceived as effective strategies. Social policy and research implications are discussed.

  13. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  14. Trial sequential analysis reveals insufficient information size and potentially false positive results in many meta-analyses

    DEFF Research Database (Denmark)

    Brok, J.; Thorlund, K.; Gluud, C.

    2008-01-01

    in 80% (insufficient information size). TSA(15%) and TSA(LBHIS) found that 95% and 91% had absence of evidence. The remaining nonsignificant meta-analyses had evidence of lack of effect. CONCLUSION: TSA reveals insufficient information size and potentially false positive results in many meta......OBJECTIVES: To evaluate meta-analyses with trial sequential analysis (TSA). TSA adjusts for random error risk and provides the required number of participants (information size) in a meta-analysis. Meta-analyses not reaching information size are analyzed with trial sequential monitoring boundaries...... analogous to interim monitoring boundaries in a single trial. STUDY DESIGN AND SETTING: We applied TSA on meta-analyses performed in Cochrane Neonatal reviews. We calculated information sizes and monitoring boundaries with three different anticipated intervention effects of 30% relative risk reduction (TSA...

  15. Automated microaneurysm detection method based on double ring filter in retinal fundus images

    Science.gov (United States)

    Mizutani, Atsushi; Muramatsu, Chisako; Hatanaka, Yuji; Suemori, Shinsuke; Hara, Takeshi; Fujita, Hiroshi

    2009-02-01

    The presence of microaneurysms in the eye is one of the early signs of diabetic retinopathy, which is one of the leading causes of vision loss. We have been investigating a computerized method for the detection of microaneurysms on retinal fundus images, which were obtained from the Retinopathy Online Challenge (ROC) database. The ROC provides 50 training cases, in which "gold standard" locations of microaneurysms are provided, and 50 test cases without the gold standard locations. In this study, the computerized scheme was developed by using the training cases. Although the results for the test cases are also included, this paper mainly discusses the results for the training cases because the "gold standard" for the test cases is not known. After image preprocessing, candidate regions for microaneurysms were detected using a double-ring filter. Any potential false positives located in the regions corresponding to blood vessels were removed by automatic extraction of blood vessels from the images. Twelve image features were determined, and the candidate lesions were classified into microaneurysms or false positives using the rule-based method and an artificial neural network. The true positive fraction of the proposed method was 0.45 at 27 false positives per image. Forty-two percent of microaneurysms in the 50 training cases were considered invisible by the consensus of two co-investigators. When the method was evaluated for visible microaneurysms, the sensitivity for detecting microaneurysms was 65% at 27 false positives per image. Our computerized detection scheme could be improved for helping ophthalmologists in the early diagnosis of diabetic retinopathy.

  16. Method for position emission mammography image reconstruction

    Science.gov (United States)

    Smith, Mark Frederick

    2004-10-12

    An image reconstruction method comprising accepting coincidence datat from either a data file or in real time from a pair of detector heads, culling event data that is outside a desired energy range, optionally saving the desired data for each detector position or for each pair of detector pixels on the two detector heads, and then reconstructing the image either by backprojection image reconstruction or by iterative image reconstruction. In the backprojection image reconstruction mode, rays are traced between centers of lines of response (LOR's), counts are then either allocated by nearest pixel interpolation or allocated by an overlap method and then corrected for geometric effects and attenuation and the data file updated. If the iterative image reconstruction option is selected, one implementation is to compute a grid Siddon retracing, and to perform maximum likelihood expectation maiximization (MLEM) computed by either: a) tracing parallel rays between subpixels on opposite detector heads; or b) tracing rays between randomized endpoint locations on opposite detector heads.

  17. MR imaging of recurrent hyperparathyroidism in comparison with other imaging modalities

    International Nuclear Information System (INIS)

    Auffermann, W.; Thurnher, S.; Okerland, M.; Levin, K.; Gooding, G.W.; Clark, O.H.; Higgins, C.B.

    1987-01-01

    Thirty patients with recurrent hyperparathyroidism were evaluated with MR imaging, performed using a saddle-shaped surface coil producing 5-mm sections with T1 and T2 weighting. Twenty-six and 22 of these patients also underwent T1-201 scintigraphy and high-resolution US, respectively. MR imaging accurately localized abnormal parathyroid glands in 75% evaluated prospectively and 86% retrospectively. Scintigraphy localized 64% prospectively and 72% retrospectively. US demonstrated 57% prospectively and 67% retrospectively. MR imaging showed three of four mediastinal adenomas evaluated prospectively retrospectively. There were two false-positive studies with MR imaging, two with scintigraphy, and one with US. Thus, MR imaging was the most effective imaging modality for parathyroid localization in recurrent hyperparathyroidism

  18. Validation of Diagnostic Imaging Based on Repeat Examinations. An Image Interpretation Model

    International Nuclear Information System (INIS)

    Isberg, B.; Jorulf, H.; Thorstensen, Oe.

    2004-01-01

    Purpose: To develop an interpretation model, based on repeatedly acquired images, aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. Material and Methods: A theoretical model is proposed. The studied population consists of subjects that develop focal lesions which increase in size in organs of interest during the study period. The imaging modality produces images that can be re-interpreted with high precision, e.g. conventional radiography, computed tomography, and magnetic resonance imaging. At least four repeat examinations are carried out. Results: The interpretation is performed in four or five steps: 1. Independent readers interpret the examinations chronologically without access to previous or subsequent films. 2. Lesions found on images at the last examination are included in the analysis, with interpretation in consensus. 3. By concurrent back-reading in consensus, the lesions are identified on previous images until they are so small that even in retrospect they are undetectable. The earliest examination at which included lesions appear is recorded, and the lesions are verified by their growth (imaging reference standard). Lesion size and other characteristics may be recorded. 4. Records made at step 1 are corrected to those of steps 2 and 3. False positives are recorded. 5. (Optional) Lesion type is confirmed by another diagnostic test. Conclusion: Applied on subjects with progressive disease, the proposed image interpretation model may improve assessments of technical efficacy and diagnostic accuracy in the detection of small focal lesions. The model may provide an accurate imaging reference standard as well as repeated detection rates and false-positive rates for tested imaging modalities. However, potential review bias necessitates a strict protocol

  19. Indium-111 chloride imaging in the detection of infected prostheses

    International Nuclear Information System (INIS)

    Sayle, B.A.; Fawcett, H.D.; Wilkey, D.J.; Cierny, G. III; Mader, J.T.

    1985-01-01

    Thirty-three patients with painful joint prostheses and a suspicion of infection were imaged with [ 111 In]chloride. A final diagnosis was established by culture in 19. Of these, 12 were categorized as true positives and three as true negatives. There were two false-positive studies, occurring in patients with knee prostheses. In both, the culture was obtained by aspiration. The sensitivity was 86%, specificity 60%, and accuracy 79%. Seventeen of the proven cases had bone imaging prior to [ 111 In]chloride imaging. All 17 static images were positive and were not helpful in differentiating loosening from infection. Using increased uptake on the blood-pool image as a criteria for infection, the sensitivity was 89%, but the specificity was 0. Adding flow studies made little difference in interpreting the blood-pool images. This study shows that [ 111 In]chloride imaging is more accurate in evaluating infection in prosthesis than bone imaging

  20. New approach to imaging HIV-positive patients with pyrexia of undetermined origin

    International Nuclear Information System (INIS)

    Buscombe, J.; Miller, R.; Lui, D.; Ell, P.J.

    1990-01-01

    This paper established if imaging with Tc-99m human immunoglobulin (HIG) in addition to Ga-67 citrate increased the diagnostic sensitivity in patients who have pyrexia of unknown origin (PUO) and who have tested positive for human immunodeficiency virus (HIV). The authors studied 18 HIV-positive patients with PUO for 3 or more weeks. Imaging was performed 4 and 20 hours after administration of 200 MBq of Tc-99m HIG and 24, 48, and (if indicated) 72 hours after administration of 300 MBq of Ga-67. Anterior whole body and relevant spot view were obtained for both agents. Twenty-four sites of infection were confirmed microbiologically in 12 patients. Ga-67 scan results were positive in 22 of these sites, and Tc-99m HIG results were positive in 13; the nine Ga-positive sites that were Tc-negative were intrathoracic (one Pneumocystis carinii, eight Mycobacterium intracellulare)

  1. Memory Distortion and Its Avoidance: An Event-Related Potentials Study on False Recognition and Correct Rejection.

    Science.gov (United States)

    Cadavid, Sara; Beato, Maria Soledad

    2016-01-01

    Memory researchers have long been captivated by the nature of memory distortions and have made efforts to identify the neural correlates of true and false memories. However, the underlying mechanisms of avoiding false memories by correctly rejecting related lures remains underexplored. In this study, we employed a variant of the Deese/Roediger-McDermott paradigm to explore neural signatures of committing and avoiding false memories. ERP were obtained for True recognition, False recognition, Correct rejection of new items, and, more importantly, Correct rejection of related lures. With these ERP data, early-frontal, left-parietal, and late right-frontal old/new effects (associated with familiarity, recollection, and monitoring processes, respectively) were analysed. Results indicated that there were similar patterns for True and False recognition in all three old/new effects analysed in our study. Also, False recognition and Correct rejection of related lures activities seemed to share common underlying familiarity-based processes. The ERP similarities between False recognition and Correct rejection of related lures disappeared when recollection processes were examined because only False recognition presented a parietal old/new effect. This finding supported the view that actual false recollections underlie false memories, providing evidence consistent with previous behavioural research and with most ERP and neuroimaging studies. Later, with the onset of monitoring processes, False recognition and Correct rejection of related lures waveforms presented, again, clearly dissociated patterns. Specifically, False recognition and True recognition showed more positive going patterns than Correct rejection of related lures signal and Correct rejection of new items signature. Since False recognition and Correct rejection of related lures triggered familiarity-recognition processes, our results suggest that deciding which items are studied is based more on recollection

  2. Memory Distortion and Its Avoidance: An Event-Related Potentials Study on False Recognition and Correct Rejection.

    Directory of Open Access Journals (Sweden)

    Sara Cadavid

    Full Text Available Memory researchers have long been captivated by the nature of memory distortions and have made efforts to identify the neural correlates of true and false memories. However, the underlying mechanisms of avoiding false memories by correctly rejecting related lures remains underexplored. In this study, we employed a variant of the Deese/Roediger-McDermott paradigm to explore neural signatures of committing and avoiding false memories. ERP were obtained for True recognition, False recognition, Correct rejection of new items, and, more importantly, Correct rejection of related lures. With these ERP data, early-frontal, left-parietal, and late right-frontal old/new effects (associated with familiarity, recollection, and monitoring processes, respectively were analysed. Results indicated that there were similar patterns for True and False recognition in all three old/new effects analysed in our study. Also, False recognition and Correct rejection of related lures activities seemed to share common underlying familiarity-based processes. The ERP similarities between False recognition and Correct rejection of related lures disappeared when recollection processes were examined because only False recognition presented a parietal old/new effect. This finding supported the view that actual false recollections underlie false memories, providing evidence consistent with previous behavioural research and with most ERP and neuroimaging studies. Later, with the onset of monitoring processes, False recognition and Correct rejection of related lures waveforms presented, again, clearly dissociated patterns. Specifically, False recognition and True recognition showed more positive going patterns than Correct rejection of related lures signal and Correct rejection of new items signature. Since False recognition and Correct rejection of related lures triggered familiarity-recognition processes, our results suggest that deciding which items are studied is based more on

  3. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnaure, I.; Lovblad, K.O.; Vargas, M.I. [Geneva University Hospital, Department of Neuroradiology, Geneva 14 (Switzerland); Pollak, P.; Horvath, J.; Boex, C.; Burkhard, P. [Geneva University Hospital, Department of Neurology, Geneva (Switzerland); Momjian, S. [Geneva University Hospital, Department of Neurosurgery, Geneva (Switzerland); Remuinan, J. [Geneva University Hospital, Department of Radiology, Geneva (Switzerland)

    2015-09-15

    Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS. (orig.)

  4. THE POSSIBLE MOON OF KEPLER-90g IS A FALSE POSITIVE

    Energy Technology Data Exchange (ETDEWEB)

    Kipping, D. M.; Torres, G.; Buchhave, L. A. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Huang, X.; Bakos, G. Á. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 05844 (United States); Nesvorný, D. [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States); Schmitt, A. R., E-mail: dkipping@cfa.harvard.edu

    2015-01-20

    The discovery of an exomoon would provide deep insights into planet formation and the habitability of planetary systems, with transiting examples being particularly sought after. Of the hundreds of Kepler planets now discovered, the seven-planet system Kepler-90 is unusual for exhibiting an unidentified transit-like signal in close proximity to one of the transits of the long-period gas-giant Kepler-90g, as noted by Cabrera et al. As part of the ''Hunt for Exomoons with Kepler'' project, we investigate this possible exomoon signal and find it passes all conventional photometric, dynamical, and centroid diagnostic tests. However, pixel-level light curves indicate that the moon-like signal occurs on nearly all of the target's pixels, which we confirm using a novel way of examining pixel-level data which we dub the ''transit centroid''. This test reveals that the possible exomoon to Kepler-90g is likely a false positive, perhaps due to a cosmic ray induced sudden pixel sensitivity dropout. This work highlights the extreme care required for seeking non-periodic low-amplitude transit signals, such as exomoons.

  5. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Lamba, Michael; Breneman, John C.; Warnick, Ronald E.

    2009-01-01

    Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 ± 0.5 mm) and image-guided (0.6 ± 0.2 mm) techniques. The in vivo differences in alignment were 0.9 ± 0.5 mm (anteroposterior), -0.2 ± 0.4 mm (superoinferior), and 0.3 ± 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 ± 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

  6. Should single-phase radionuclide bone imaging be used in suspected osteomyelitis

    International Nuclear Information System (INIS)

    Fihn, S.D.; Larson, E.B.; Nelp, W.B.; Rudd, T.G.; Gerber, F.H.

    1984-01-01

    The records of 69 patients who had 86 delayed, static radionuclide bone images for suspected osteomyelitis were studied to determine the effects of this procedure on diagnosis and treatment. Sensitivity, specificity, and positive predictive value were lower than reported in several other studies. When osteomyelitis was unlikely, imaging was either negative or falsely positive and rarely affected treatment. In 46 cases where osteomyelitis was more likely, imaging potentially changed therapy in 19 but was unhelpful or misleading in 15. Static-phase images with ''definite'' interpretations, particularly when negative, are specific, but ''equivocal'' studies may lead to diagnostic and therapeutic errors. When ostemyelitis is improbable, imaging rarely changes diagnosis or therapy

  7. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  8. [False positive results or what's the probability that a significant P-value indicates a true effect?

    Science.gov (United States)

    Cucherat, Michel; Laporte, Silvy

    2017-09-01

    The use of statistical test is central in the clinical trial. At the statistical level, obtaining a Pinformation about the plausibility of the existence of treatment effect. With "Pfalse positive is very high. This is the case if the power is low, if there is an inflation of the alpha risk or if the result is exploratory or chance discoveries. This possibility is important to take into consideration when interpreting the results of clinical trials in order to avoid pushing ahead significant results in appearance, but which are likely to be actually false positive results. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  9. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    International Nuclear Information System (INIS)

    Bernatowicz, K.; Knopf, A.; Lomax, A.; Keall, P.; Kipritidis, J.; Mishra, P.

    2015-01-01

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm 3 spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged

  10. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bernatowicz, K., E-mail: kingab@student.ethz.ch; Knopf, A.; Lomax, A. [Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI 5232, Switzerland and Department of Physics, ETH Zürich, Zürich 8092 (Switzerland); Keall, P.; Kipritidis, J., E-mail: john.kipritidis@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, NSW 2006 (Australia); Mishra, P. [Brigham and Womens Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-01-15

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results

  11. Imaging spectrum and pitfalls of {sup 11}C-methionine position emission tomography in a series of patients with intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kimiteru [Dept. of Radiology, Tokyo Metropolitan Geriatric Hospital and Institute of Gerontology, Tokyo (Japan); Matsuda, Hiroshi [Integrative Brain Imaging Center, National Center of Neurology and Psychiatry, Tokyo (Japan); Kubota, Kazoo [Div. of Nuclear Medicine, National Center for Global Health and Medicine, Tokyo (Japan)

    2016-06-15

    {sup 11}C-methionine (Met) positron emission tomography (PET) is one of the most commonly used PET tracers for evaluating brain tumors. However, few reports have described tips and pitfalls of {sup 11}C-Met PET for general practitioners. Physiological {sup 11}C-Met uptake, anatomical variations, vascular disorders, non-tumorous lesions such as inflammation or dysplasia, benign brain tumors and patient condition during {sup 11}C-Met PET examination can potentially affect the image interpretation and cause false positives and negatives. These pitfalls in the interpretation of {sup 11}C-Met PET images are important for not only nuclear medicine physicians but also general radiologists. Familiarity with the spectrum and pitfalls of {sup 11}C-Met images could help prevent unfavorable clinical results caused by misdiagnoses.

  12. Image Positioning Accuracy Analysis for Super Low Altitude Remote Sensing Satellites

    Directory of Open Access Journals (Sweden)

    Ming Xu

    2012-10-01

    Full Text Available Super low altitude remote sensing satellites maintain lower flight altitudes by means of ion propulsion in order to improve image resolution and positioning accuracy. The use of engineering data in design for achieving image positioning accuracy is discussed in this paper based on the principles of the photogrammetry theory. The exact line-of-sight rebuilding of each detection element and this direction precisely intersecting with the Earth's elliptical when the camera on the satellite is imaging are both ensured by the combined design of key parameters. These parameters include: orbit determination accuracy, attitude determination accuracy, camera exposure time, accurately synchronizing the reception of ephemeris with attitude data, geometric calibration and precise orbit verification. Precise simulation calculations show that image positioning accuracy of super low altitude remote sensing satellites is not obviously improved. The attitude determination error of a satellite still restricts its positioning accuracy.

  13. Position Estimation and Local Mapping Using Omnidirectional Images and Global Appearance Descriptors

    Directory of Open Access Journals (Sweden)

    Yerai Berenguer

    2015-10-01

    Full Text Available This work presents some methods to create local maps and to estimate the position of a mobile robot, using the global appearance of omnidirectional images. We use a robot that carries an omnidirectional vision system on it. Every omnidirectional image acquired by the robot is described only with one global appearance descriptor, based on the Radon transform. In the work presented in this paper, two different possibilities have been considered. In the first one, we assume the existence of a map previously built composed of omnidirectional images that have been captured from previously-known positions. The purpose in this case consists of estimating the nearest position of the map to the current position of the robot, making use of the visual information acquired by the robot from its current (unknown position. In the second one, we assume that we have a model of the environment composed of omnidirectional images, but with no information about the location of where the images were acquired. The purpose in this case consists of building a local map and estimating the position of the robot within this map. Both methods are tested with different databases (including virtual and real images taking into consideration the changes of the position of different objects in the environment, different lighting conditions and occlusions. The results show the effectiveness and the robustness of both methods.

  14. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    Science.gov (United States)

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  15. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  16. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    International Nuclear Information System (INIS)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.; Webber, M.M.; Amstutz, H.C.

    1987-01-01

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletal sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement

  17. False memory for context and true memory for context similarly activate the parahippocampal cortex.

    Science.gov (United States)

    Karanian, Jessica M; Slotnick, Scott D

    2017-06-01

    The role of the parahippocampal cortex is currently a topic of debate. One view posits that the parahippocampal cortex specifically processes spatial layouts and sensory details (i.e., the visual-spatial processing view). In contrast, the other view posits that the parahippocampal cortex more generally processes spatial and non-spatial contexts (i.e., the general contextual processing view). A large number of studies have found that true memories activate the parahippocampal cortex to a greater degree than false memories, which would appear to support the visual-spatial processing view as true memories are typically associated with greater visual-spatial detail than false memories. However, in previous studies, contextual details were also greater for true memories than false memories. Thus, such differential activity in the parahippocampal cortex may have reflected differences in contextual processing, which would challenge the visual-spatial processing view. In the present functional magnetic resonance imaging (fMRI) study, we employed a source memory paradigm to investigate the functional role of the parahippocampal cortex during true memory and false memory for contextual information to distinguish between the visual-spatial processing view and the general contextual processing view. During encoding, abstract shapes were presented to the left or right of fixation. During retrieval, old shapes were presented at fixation and participants indicated whether each shape was previously on the "left" or "right" followed by an "unsure", "sure", or "very sure" confidence rating. The conjunction of confident true memories for context and confident false memories for context produced activity in the parahippocampal cortex, which indicates that this region is associated with contextual processing. Furthermore, the direct contrast of true memory and false memory produced activity in the visual cortex but did not produce activity in the parahippocampal cortex. The present

  18. No effect of stress on false recognition.

    Science.gov (United States)

    Beato, María Soledad; Cadavid, Sara; Pulido, Ramón F; Pinho, María Salomé

    2013-02-01

    The present study aimed to analyze the effect of acute stress on false recognition in the Deese/Roediger-McDermott (DRM) paradigm. In this paradigm, lists of words associated with a non-presented critical lure are studied and, in a subsequent memory test, critical lures are often falsely remembered. In two experiments, participants were randomly assigned to either the stress group (Trier Social Stress Test) or the no-stress control group. Because we sought to control the level-of-processing at encoding, in Experiment 1, participants created a visual mental image for each presented word (deep encoding). In Experiment 2, participants performed a shallow encoding (to respond whether each word contained the letter "o"). The results indicated that, in both experiments, as predicted, heart rate and STAI-S scores increased only in the stress group. However, false recognition did not differ across stress and no-stress groups. Results suggest that, although psychosocial stress was successfully induced, it does not enhance the vulnerability of individuals with acute stress to DRM false recognition, regardless of the level of processing.

  19. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  20. Verification of patient position and delivery of IMRT by electronic portal imaging

    International Nuclear Information System (INIS)

    Fielding, Andrew L.; Evans, Philip M.; Clark, Catharine H.

    2004-01-01

    Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 2 deg. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam

  1. Multiplex Mass Spectrometric Imaging with Polarity Switching for Concurrent Acquisition of Positive and Negative Ion Images

    Science.gov (United States)

    Korte, Andrew R.; Lee, Young Jin

    2013-06-01

    We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393-9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.

  2. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  3. Hippocampal size is related to short-term true and false memory, and right fusiform size is related to long-term true and false memory.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; He, Qinghua; Lei, Xuemei; Dong, Qi; Lin, Chongde

    2016-11-01

    There is a keen interest in identifying specific brain regions that are related to individual differences in true and false memories. Previous functional neuroimaging studies showed that activities in the hippocampus, right fusiform gyrus, and parahippocampal gyrus were associated with true and false memories, but no study thus far has examined whether the structures of these brain regions are associated with short-term and long-term true and false memories. To address that question, the current study analyzed data from 205 healthy young adults, who had valid data from both structural brain imaging and a misinformation task. In the misinformation task, subjects saw the crime scenarios, received misinformation, and took memory tests about the crimes an hour later and again after 1.5 years. Results showed that bilateral hippocampal volume was associated with short-term true and false memories, whereas right fusiform gyrus volume and surface area were associated with long-term true and false memories. This study provides the first evidence for the structural neural bases of individual differences in short-term and long-term true and false memories.

  4. Modeling decision-making in single- and multi-modal medical images

    Science.gov (United States)

    Canosa, R. L.; Baum, K. G.

    2009-02-01

    This research introduces a mode-specific model of visual saliency that can be used to highlight likely lesion locations and potential errors (false positives and false negatives) in single-mode PET and MRI images and multi-modal fused PET/MRI images. Fused-modality digital images are a relatively recent technological improvement in medical imaging; therefore, a novel component of this research is to characterize the perceptual response to these fused images. Three different fusion techniques were compared to single-mode displays in terms of observer error rates using synthetic human brain images generated from an anthropomorphic phantom. An eye-tracking experiment was performed with naÃve (non-radiologist) observers who viewed the single- and multi-modal images. The eye-tracking data allowed the errors to be classified into four categories: false positives, search errors (false negatives never fixated), recognition errors (false negatives fixated less than 350 milliseconds), and decision errors (false negatives fixated greater than 350 milliseconds). A saliency model consisting of a set of differentially weighted low-level feature maps is derived from the known error and ground truth locations extracted from a subset of the test images for each modality. The saliency model shows that lesion and error locations attract visual attention according to low-level image features such as color, luminance, and texture.

  5. Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening

    Science.gov (United States)

    Weinstein, Susan P.; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Digital breast tomosynthesis (DBT) represents a valuable addition to breast cancer screening by decreasing recall rates while increasing cancer detection rates. The increased accuracy achieved with DBT is due to the quasi–three-dimensional format of the reconstructed images and the ability to “scroll through” breast tissue in the reconstructed images, thereby reducing the effect of tissue superimposition found with conventional planar digital mammography. The margins of both benign and malignant lesions are more conspicuous at DBT, which allows improved lesion characterization, increased reader confidence, and improved screening outcomes. However, even with the improvements in accuracy achieved with DBT, there remain differences in breast cancer conspicuity by mammographic view. Early data suggest that breast cancers may be more conspicuous on craniocaudal (CC) views than on mediolateral oblique (MLO) views. While some very laterally located breast cancers may be visualized on only the MLO view, the increased conspicuity of cancers on the CC view compared with the MLO view suggests that DBT screening should be performed with two-view imaging. Even with the improved conspicuity of lesions at DBT, there may still be false-negative studies. Subtle lesions seen on only one view may be discounted, and dense and/or complex tissue patterns may make some cancers occult or extremely difficult to detect. Therefore, radiologists should be cognizant of both perceptual and cognitive errors to avoid potential pitfalls in lesion detection and characterization. ©RSNA, 2016 Online supplemental material is available for this article. PMID:27715711

  6. SU-E-J-189: Determination of Markerless Lung Tumor Position in Real Time: A Feasibility Study Using a Novel Tomo-Cinegraphy Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Hu, E; Yu, C; Lee, M; Lasio, G [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: A Tomo-Cinegraphy (TC) is a method to generate a series of temporal tomographic images from projection images of the on-board imager (OBI) while gantry is moving. It is to test if this technique is useful to determine a lung tumor position during treatments. Methods: Tomographic image via background subtraction, TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). This idea was extended to a TC, which enables to generate tomographic images of same geometry from the projection of different gantry angles and different breathing phases. Projection images of a lung patient for CBCT acquisition are used to generate TC images. A region of interest (ROI) is selected around a tumor adding 2cm margins. Center of mass (COM) of the ROI is traced to determine tumor position for every projection images. Results: Tumor is visible in the TC images while the OBI projections are not. The coordinates of the COMs represent the temporal tumor positions. While, it is not possible to trace the tumor motion using the projection images. A source of time delay is the time to acquire projection images, which is always less than a second. Conclusion: TC allows tracking the tumor positions without fiducial markers in real time for some lung patients, if the projection images are acquired during treatments. Partially supported by NIH R01CA133539.

  7. Applying a CAD-generated imaging marker to assess short-term breast cancer risk

    Science.gov (United States)

    Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin

    2018-02-01

    Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (pbreast cancer risk.

  8. Clinical value of imaging using antibody to alpha fetoprotein in germ cell tumours

    International Nuclear Information System (INIS)

    Hitchins, R.N.; Begent, R.H.J.; Green, A.J.; Searle, F.; Bagshawe, K.D.; Charing Cross Group of Hospitals, London; Van Heyningen, V.

    1989-01-01

    Germ cell tumours (GCT) producing alpha fetoprotein (aFP) can be imaged by external scintigraphy after intraveneous administration of radiolabelled antibody directed against aFP. Antibody imaging (AI) by this method was used in an attempt to guide surgical resection of deposits of drug-resistant or recurrent GCT. 30 patients with GCT and raised aFP in whom site of tumour was not known were investigated by AI and conventional imaging methods. All but one were heavily pretreated. Where tumour appeared localised, resection was attempted. Tumour was found in all sites positive by both AI and conventional imaging. AI produced false-positive results in one of 30 patients and false-negative results in 9 patients. Computerised tomography was false-positive in one case and false-negative in three. In these patients, AI gave true-negative and true-positive results, respectively. Of 11 patients with positive AI in whom resection was attempted, 6 achieved sustained complete response with up to 5 years follow-up. We conclude AI and conventional imaging methods to be complementary in selection for surgery of patients with drug-resistant or recurrent GCT. (orig.) [de

  9. Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study

    Directory of Open Access Journals (Sweden)

    Vickers Andrew J

    2008-11-01

    Full Text Available Abstract Background A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives. Methods A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC corrected for verification bias varying both the rate and mechanism of verification. Results In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th – 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations. Conclusion Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.

  10. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. A Study on the Effectiveness of the Manufacture of Compensator and Setup Position for Total Body Irradiation Using Computed Tomography-simulator's Images

    International Nuclear Information System (INIS)

    Lee, Woo Suk; Kim, Dae Sup; Park, Seong Ho; Yun, In Ha; Back, Geum Mun; Kim, Jeong Man

    2005-01-01

    We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability. Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department. About thickness at body measure point. we could find difference of 1-2 cm relationship general measure and image measure. General measure and image measure of body length was seen difference of 3-4 cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by 92-98% and abdomen, pelvis, inquinal region, feet region were measured by 102-109%. It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly, and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall 15 minute time. and reduce compensator manufacture time about 15 minutes.

  12. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  13. Affective valence influences participant's susceptibility to false memories and illusory recollection.

    Science.gov (United States)

    Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial

    2010-10-01

    This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  14. INDOOR POSITIONING AND NAVIGATION BASED ON CONTROL SPHERECAL PANORAMIC IMAGES

    Directory of Open Access Journals (Sweden)

    T.-C. Huang

    2016-06-01

    Full Text Available Continuous indoor and outdoor positioning and navigation is the goal to achieve in the field of mobile mapping technology. However, accuracy of positioning and navigation will be largely degraded in indoor or occluded areas, due to receiving weak or less GNSS signals. Targeting the need of high accuracy indoor and outdoor positioning and navigation for mobile mapping applications, the objective of this study is to develop a novel method of indoor positioning and navigation with the use of spherical panoramic image (SPI. Two steps are planned in the technology roadmap. First, establishing a control SPI database that contains a good number of well-distributed control SPIs pre-acquired in the target space. A control SPI means an SPI with known exterior orientation parameters, which can be solved with a network bundle adjustment of SPIs. Having a control SPI database, the target space will be ready to provide the service of positioning and navigation. Secondly, the position and orientation of a newly taken SPI can be solved by using overlapped SPIs searched from the control SPI database. The method of matching SPIs and finding conjugate image features will be developed and tested. Two experiments will be planned and conducted in this paper to test the feasibility and validate the test results of the proposed methods. Analysis of appropriate number and distribution of needed control SPIs will also be included in the experiments with respect to different test cases.

  15. Combination of RNA- and exome-sequencing efficiently eliminates false-positive somatic point mutations and indels – exemplified by cases of CN-AML

    DEFF Research Database (Denmark)

    Herborg, Laura Laine; Hansen, Marcus Celik; Roug, Anne Stidsholt

    Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive observat......Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive...... in the workflow, not only provides information on malignant expression profiles excluded here, but importantly help to capture the, often very few somatic mutations of myeloid leukaemia....

  16. The effect of patient positioning on MR imaging of the internal auditory canal

    International Nuclear Information System (INIS)

    Daniels, D.L.; Czervionke, L.F.; Yu, S.; Ho, P.S.P.; Pech, P.; Pojunas, K.W.; Williams, A.L.; Haughton, V.M.

    1988-01-01

    Identification of individual cranial nerves and complete exclusion of tumor in the internal auditory canal may be difficult with MR, especially in imperfectly positioned patients. MR studies of the temporal bones in patients and in normal volunteers positioned non-rotated or canted were correlated with corresponding cryomicrotomic sections. Especially in axial images, oblique sectioning of cranial nerves VII and VIII may cause difficulty in identifying individual nerves. A combination of axial and coronal short TR and TE images can be used to confidently exclude intracanalicular tumor in most cases. (orig.)

  17. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    Science.gov (United States)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  18. Positive media portrayals of obese persons: impact on attitudes and image preferences.

    Science.gov (United States)

    Pearl, Rebecca L; Puhl, Rebecca M; Brownell, Kelly D

    2012-11-01

    The purpose of this research was to assess the impact of nonstereotypical, positive media portrayals of obese persons on biased attitudes, as well as propose a change in media practices that could reduce public weight bias and consequent negative health outcomes for those who experience weight stigma. Two online experiments were conducted in which participants viewed either a stigmatizing or a positive photograph of an obese model. In Experiment 1 (N = 146), participants viewed a photograph of either a Caucasian or African American obese woman; in Experiment 2 (N = 145), participants viewed either a Caucasian male or female obese model. Multiple linear regression models were used to analyze outcomes for social distance attitudes toward the obese models depicted in the images, in addition to other negative attitudes and image preferences. Participants who viewed the stigmatizing images endorsed stronger social distance attitudes and more negative attitudes toward obese persons than participants who viewed the positive images, and there was a stronger preference for the positive images than the stigmatizing images. These results were consistent regardless of the race or gender of the obese model pictured. The findings indicate that more positive media portrayals of obese individuals may help reduce weight stigma and its associated negative health outcomes.

  19. Waif goodbye! Average-size female models promote positive body image and appeal to consumers.

    Science.gov (United States)

    Diedrichs, Phillippa C; Lee, Christina

    2011-10-01

    Despite consensus that exposure to media images of thin fashion models is associated with poor body image and disordered eating behaviours, few attempts have been made to enact change in the media. This study sought to investigate an effective alternative to current media imagery, by exploring the advertising effectiveness of average-size female fashion models, and their impact on the body image of both women and men. A sample of 171 women and 120 men were assigned to one of three advertisement conditions: no models, thin models and average-size models. Women and men rated average-size models as equally effective in advertisements as thin and no models. For women with average and high levels of internalisation of cultural beauty ideals, exposure to average-size female models was associated with a significantly more positive body image state in comparison to exposure to thin models and no models. For men reporting high levels of internalisation, exposure to average-size models was also associated with a more positive body image state in comparison to viewing thin models. These findings suggest that average-size female models can promote positive body image and appeal to consumers.

  20. Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Oh, Ji Eun; Woo, Seung Tae

    2008-01-01

    Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at 60 .deg. C in oven overnight for hardening. Four sealed pipe tips containing [ 18 F]FDG solution were used as fiduciary markers. After injection of [ 18 F]FDG via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment

  1. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  2. Analyzing prospective teachers' images of scientists using positive, negative and stereotypical images of scientists

    Science.gov (United States)

    Subramaniam, Karthigeyan; Esprívalo Harrell, Pamela; Wojnowski, David

    2013-04-01

    Background and purpose : This study details the use of a conceptual framework to analyze prospective teachers' images of scientists to reveal their context-specific conceptions of scientists. The conceptual framework consists of context-specific conceptions related to positive, stereotypical and negative images of scientists as detailed in the literature on the images, role and work of scientists. Sample, design and method : One hundred and ninety-six drawings of scientists, generated by prospective teachers, were analyzed using the Draw-A-Scientist-Test Checklist (DAST-C), a binary linear regression and the conceptual framework. Results : The results of the binary linear regression analysis revealed a statistically significant difference for two DAST-C elements: ethnicity differences with regard to drawing a scientist who was Caucasian and gender differences for indications of danger. Analysis using the conceptual framework helped to categorize the same drawings into positive, stereotypical, negative and composite images of a scientist. Conclusions : The conceptual framework revealed that drawings were focused on the physical appearance of the scientist, and to a lesser extent on the equipment, location and science-related practices that provided the context of a scientist's role and work. Implications for teacher educators include the need to understand that there is a need to provide tools, like the conceptual framework used in this study, to help prospective teachers to confront and engage with their multidimensional perspectives of scientists in light of the current trends on perceiving and valuing scientists. In addition, teacher educators need to use the conceptual framework, which yields qualitative perspectives about drawings, together with the DAST-C, which yields quantitative measure for drawings, to help prospective teachers to gain a holistic outlook on their drawings of scientists.

  3. The "Facebook-self": characteristics and psychological predictors of false self-presentation on Facebook.

    Science.gov (United States)

    Gil-Or, Oren; Levi-Belz, Yossi; Turel, Ofir

    2015-01-01

    In this study we present and empirically examine a new phenomenon related to social networking sites, such as Facebook, the "false Facebook-self." Arguably false self-presentation on Facebook is a growing phenomenon, and in extreme cases; i.e., when ones Facebook image substantially deviates from their true image, it may serve as a gateway behavior to more problematic behaviors which may lead to psychological problems and even pathologies. In this study we show that certain users are more vulnerable to such false self-presentation than others. The study involved 258 Facebook users. Applying ANOVA and SEM analyses we show that users with low self-esteem and low trait authenticity are more likely than others to present a Facebook-self which deviates from their true selves. These social-interaction-related traits are influenced by one's upbringing and the anxious and avoidant attachment styles he or she has developed. Several cases (7.5%) with large gaps between the true and false Facebook-self were detected, which implies that future research should consider the adverse consequences and treatments of high levels of false Facebook-self.

  4. The Formation of a Positive International Image of Country as a Means of Enhancing Competitiveness

    Directory of Open Access Journals (Sweden)

    Novikova Ludmyla V.

    2017-11-01

    Full Text Available The article is aimed at studying the essence of the concept of «image of the state» and substantiating the conceptual model of forming a positive international image of country as a means of enhancing competitiveness in the international market. The essence of the concept of «image of the State» has been defined. The factors influencing the formation of the international image of country have been distributed and systematized. The principles on which the process of formation of country image of modern format, receiving public recognition and adequate international estimation, have been allocated. A conceptual model of formation of positive international image of country, based on the hypothesis of influence of positive image on creation of significant competitive advantages in the international market of goods and services, has been proposed. The key features of the model are defined as: clear distribution of the roles of the stakeholders of national image – subjects of the global economic system, level of their involvement in the process of formation and integration of the State economy into the system of international institutions.

  5. Intellectual factors in false memories of patients with schizophrenia.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun

    2018-07-01

    The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Motivated reconstruction: The effect of brand commitment on false memories.

    Science.gov (United States)

    Montgomery, Nicole Votolato; Rajagopal, Priyali

    2018-06-01

    Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  8. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  9. The effect of mood on false memory for emotional DRM word lists.

    Science.gov (United States)

    Zhang, Weiwei; Gross, Julien; Hayne, Harlene

    2017-04-01

    In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.

  10. Working memory affects false memory production for emotional events.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  11. Activating the critical lure during study is unnecessary for false recognition.

    Science.gov (United States)

    Zeelenberg, René; Boot, Inge; Pecher, Diane

    2005-06-01

    Participants studied lists of nonwords (e.g., froost, floost, stoost, etc.) that were orthographic-phonologically similar to a nonpresented critical lure, which was also a nonword (e.g., ploost). Experiment 1 showed a high level of false recognition for the critical lure. Experiment 2 showed that the false recognition effect was also present for forewarned participants who were informed about the nature of the false recognition effect and told to avoid making false recognition judgments. The present results show that false recognition effects can be obtained even when the critical lure itself is not stored during study. This finding is problematic for accounts that attribute false memories to implicit associative responses or spreading activation but is easily explained by global familiarity models of recognition memory.

  12. Anatomy of a wrong diagnosis: false Sinus Venosus Atrial Septal Defect

    Directory of Open Access Journals (Sweden)

    Montresor Graziano

    2003-11-01

    Full Text Available Abstract In contrast with transthoracic echocardiography, transesophageal echocardiography provides a sure way to make the diagnosis of sinus venosus atrial septal defect; on the other hand this abnormality is more complex than that seen with the secundum atrial septal defect, and inexperienced operators may fail to recognize properly the defect. In front of a high reported sensitivity using transesophageal echocardiography, specificity is difficult to assess, due to possible underreporting of diagnostic errors. We describe a false positive diagnosis of sinus venosus atrial septal defect, in the setting of enlarged right chambers of the heart because of pressure overload. Modified anatomy of the heart, together with the presence of a prominent linear structure(probably Eustachian Valve and an incomplete examination in this case made image interpretation very prone to misinterpretation. In this anatomical setting transesophageal longitudinal "bicaval" view may be sub-optimal for examining the atrial septum, potentially showing false images that need to be known for correct image interpretation. Nonetheless, a scan plane taken more accurately at the superior level would have demonstrated/excluded the pathognomonic feature of sinus venosus atrial septal defect in the high atrial septum, between the fatty limbus and the inferior aspect of the right pulmonary artery; moreover TEE allows morphological information about the posterior structures of the heart that need to be investigated in detail for a complete diagnosis.

  13. Stacker’s Crane Position Fixing Based on Real Time Image Processing and Analysis

    Directory of Open Access Journals (Sweden)

    Kmeid Saad

    2015-06-01

    Full Text Available This study illustrates the usage of stacker cranes and image processing in automated warehouse systems. The aim is to use real time image processing and analysis for a stacker’s crane position fixing in order to use it as a pick-up and delivery system (P/D, to be controlled by a programmable logic controller unit (PLC.

  14. False memory and the associative network of happiness.

    Science.gov (United States)

    Koo, Minkyung; Oishi, Shigehiro

    2009-02-01

    This research examines the relationship between individuals' levels of life satisfaction and their associative networks of happiness. Study 1 measured European Americans' degree of false memory of happiness using the Deese-Roediger-McDermott paradigm. Scores on the Satisfaction With Life Scale predicted the likelihood of false memory of happiness but not of other lure words such as sleep . In Study 2, European American participants completed an association-judgment task in which they judged the extent to which happiness and each of 15 positive emotion terms were associated with each other. Consistent with Study 1's findings, chronically satisfied individuals exhibited stronger associations between happiness and other positive emotion terms than did unsatisfied individuals. However, Koreans and Asian Americans did not exhibit such a pattern regarding their chronic level of life satisfaction (Study 3). In combination, results suggest that there are important individual and cultural differences in the cognitive structure and associative network of happiness.

  15. Image annotation based on positive-negative instances learning

    Science.gov (United States)

    Zhang, Kai; Hu, Jiwei; Liu, Quan; Lou, Ping

    2017-07-01

    Automatic image annotation is now a tough task in computer vision, the main sense of this tech is to deal with managing the massive image on the Internet and assisting intelligent retrieval. This paper designs a new image annotation model based on visual bag of words, using the low level features like color and texture information as well as mid-level feature as SIFT, and mixture the pic2pic, label2pic and label2label correlation to measure the correlation degree of labels and images. We aim to prune the specific features for each single label and formalize the annotation task as a learning process base on Positive-Negative Instances Learning. Experiments are performed using the Corel5K Dataset, and provide a quite promising result when comparing with other existing methods.

  16. Transformation of Image Positions, Rotations, and Sizes into Shift Parameters

    DEFF Research Database (Denmark)

    Skov Jensen, A.; Lindvold, L.; Rasmussen, E.

    1987-01-01

    An optical image processing system is described that converts orientation and size to shift properties and simultaneously preserves the positional information as a shift. The system is described analytically and experimentally. The transformed image can be processed further with a classical...... correlator working with a rotational and size-invariant. multiplexed match filter. An optical robot vision system designed on this concept would be able to look at several objects simultaneously and determine their shape, size, orientation, and position with two measurements on the input scene at different...

  17. The impact of positive, negative and neutral stimuli in a virtual reality cognitive-motor rehabilitation task: a pilot study with stroke patients.

    Science.gov (United States)

    Cameirão, Mónica S; Faria, Ana Lúcia; Paulino, Teresa; Alves, Júlio; Bermúdez I Badia, Sergi

    2016-08-09

    Virtual Reality (VR) based methods for stroke rehabilitation have mainly focused on motor rehabilitation, but there is increasing interest in integrating motor and cognitive training to increase similarity to real-world settings. Unfortunately, more research is needed for the definition of which type of content should be used in the design of these tools. One possibility is the use of emotional stimuli, which are known to enhance attentional processes. According to the Socioemotional Selectivity Theory, as people age, the emotional salience arises for positive and neutral, but not for negative stimuli. For this study we developed a cognitive-motor VR task involving attention and short-term memory, and we investigated the impact of using emotional images of varying valence. The task consisted of finding a target image, shown for only two seconds, among fourteen neutral distractors, and selecting it through arm movements. After performing the VR task, a recall task took place and the patients had to identify the target images among a valence-matched number of distractors. Ten stroke patients participated in a within-subjects experiment with three conditions based on the valence of the images: positive, negative and neutral. Eye movements were recorded during VR task performance with an eye tracking system. Our results show decreased attention for negative stimuli in the VR task performance when compared to neutral stimuli. The recall task shows significantly more wrongly identified images (false memories) for negative stimuli than for neutral. Regression and correlation analyses with the Montreal Cognitive Assessment and the Geriatric Depression Scale revealed differential effects of cognitive function and depressive symptomatology in the encoding and recall of positive, negative and neutral images. Further, eye movement data shows reduced search patterns for wrongly selected stimuli containing emotional content. The results of this study suggest that it is feasible

  18. False recollection of emotional pictures in Alzheimer's disease.

    Science.gov (United States)

    Gallo, David A; Foster, Katherine T; Wong, Jessica T; Bennett, David A

    2010-10-01

    Alzheimer's Disease (AD) can reduce the effects of emotional content on memory for studied pictures, but less is known about false memory. In healthy adults, emotionally arousing pictures can be more susceptible to false memory effects than neutral pictures, potentially because emotional pictures share conceptual similarities that cause memory confusions. We investigated these effects in AD patients and healthy controls. Participants studied pictures and their verbal labels, and then picture recollection was tested using verbal labels as retrieval cues. Some of the test labels had been associated with a picture at study, whereas other had not. On this picture recollection test, we found that both AD patients and controls incorrectly endorsed some of the test labels that had not been studied with pictures. These errors were associated with medium to high levels of confidence, indicating some degree of false recollection. Critically, these false recollection judgments were greater for emotional compared to neutral items, especially for positively valenced items, in both AD patients and controls. Dysfunction of the amygdala and hippocampus in early AD may impair recollection, but AD did not disrupt the effect of emotion on false recollection judgments. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  20. Activation of Imaginal Information on True and False Memories

    Science.gov (United States)

    Chang, Sau Hou; Pierce, Benton H.

    2009-01-01

    The present study examined the activation of imaginal information on true and false memories. Participants studied a series of concrete objects in pictures or words. The imagery group (n = 96) was instructed to form images and the control group (n = 96) was not instructed to do so. Both groups were then given a standard recognition memory test and…

  1. The Norwegian healthy body image programme: study protocol for a randomized controlled school-based intervention to promote positive body image and prevent disordered eating among Norwegian high school students.

    Science.gov (United States)

    Sundgot-Borgen, Christine; Bratland-Sanda, Solfrid; Engen, Kethe M E; Pettersen, Gunn; Friborg, Oddgeir; Torstveit, Monica Klungland; Kolle, Elin; Piran, Niva; Sundgot-Borgen, Jorunn; Rosenvinge, Jan H

    2018-03-06

    Body dissatisfaction and disordered eating raise the risk for eating disorders. In the prevention of eating disorders, many programmes have proved partly successful in using cognitive techniques to combat such risk factors. However, specific strategies to actively promote a positive body image are rarely used. The present paper outlines a protocol for a programme integrating the promotion of a positive body image and the prevention of disordered eating. Using a cluster randomized controlled mixed methods design, 30 high schools and 2481 12th grade students were allocated to the Healthy Body Image programme or to a control condition. The intervention comprised three workshops, each of 90 min with the main themes body image, media literacy, and lifestyle. The intervention was interactive in nature, and were led by trained scientists. The outcome measures include standardized instruments administered pre-post intervention, and at 3 and 12 months follow-ups, respectively. Survey data cover feasibility and implementation issues. Qualitative interviews covers experiential data about students' benefits and satisfaction with the programme. The present study is one of the first in the body image and disordered eating literature that integrates a health promotion and a disease prevention approach, as well as integrating standardized outcome measures and experiential findings. Along with mediator and moderator analyses it is expected that the Healthy Body Image programme may prove its efficacy. If so, plans are made with respect to further dissemination as well as communicating the findings to regional and national decision makers in the education and health care services. The study was registered and released at ClinicalTrials.gov 21th August 2016 with the Clinical Trial.gov ID: PRSNCT02901457 . In addition, the study is approved by the Regional Committee for Medical and Health Research Ethics.

  2. Using Multispectral False Color Imaging to Characterize Tropical Cyclone Structure and Environment

    Science.gov (United States)

    Cossuth, J.; Bankert, R.; Richardson, K.; Surratt, M. L.

    2016-12-01

    The Naval Research Laboratory's (NRL) tropical cyclone (TC) web page (http://www.nrlmry.navy.mil/TC.html) has provided nearly two decades of near real-time access to TC-centric images and products by TC forecasters and enthusiasts around the world. Particularly, microwave imager and sounder information that is featured on this site provides crucial internal storm structure information by allowing users to perceive hydrometeor structure, providing key details beyond cloud top information provided by visible and infrared channels. Towards improving TC analysis techniques and helping advance the utility of the NRL TC webpage resource, new research efforts are presented. This work demonstrates results as well as the methodology used to develop new automated, objective satellite-based TC structure and intensity guidance and enhanced data fusion imagery products that aim to bolster and streamline TC forecast operations. This presentation focuses on the creation and interpretation of false color RGB composite imagery that leverages the different emissive and scattering properties of atmospheric ice, liquid, and vapor water as well as ocean surface roughness as seen by microwave radiometers. Specifically, a combination of near-realtime data and a standardized digital database of global TCs in microwave imagery from 1987-2012 is employed as a climatology of TC structures. The broad range of TC structures, from pinhole eyes through multiple eyewall configurations, is characterized as resolved by passive microwave sensors. The extraction of these characteristic features from historical data also lends itself to statistical analysis. For example, histograms of brightness temperature distributions allows a rigorous examination of how structural features are conveyed in image products, allowing a better representation of colors and breakpoints as they relate to physical features. Such climatological work also suggests steps to better inform the near-real time application of

  3. Methods for calculating the electrode position Jacobian for impedance imaging.

    Science.gov (United States)

    Boyle, A; Crabb, M G; Jehl, M; Lionheart, W R B; Adler, A

    2017-03-01

    Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.

  4. PRELIMINARY STUDY FOR THE IMPLEMENTATION OFAN IMAGE ANALYSIS ALGORITHM TO DETECT DAIRY COW PRESENCE AT THE FEED BARRIER

    Directory of Open Access Journals (Sweden)

    Simona M.C. Porto

    2012-06-01

    Full Text Available The objective of this study was to investigate the applicability of the Viola-Jones algorithm for continuous detection of the feeding behaviour of dairy cows housed in an open free-stall barn. A methodology was proposed in order to train, test and validate the classifier. A lower number of positive and negative images than those used by Viola and Jones were required during the training. The testing produced the following results: hit rate of about 97.85%, missed rate of about 2.15%, and false positive rate of about 0.67%. The validation was carried out by an accuracy assessment procedure which required the time-consuming work of an operator who labelled the true position of the cows within the barn and their behaviours. The accuracy assessment revealed that among the 715 frames about 90.63% contained only true positives, whereas about 9.37% were affected by underestimation, i.e., contained also one or two false negatives. False positives occurred only in 2.93% of the analyzed frames. Though a moderate mismatch between the testing and the validation performances was registered, the results obtained revealed the adequacy of the Viola-Jones algorithm for detecting the feeding behaviour of dairy cows housed in open free-stall barns. This, in turn, opens up opportunities for an automatic analysis of cow behaviour.

  5. How does negative emotion cause false memories?

    Science.gov (United States)

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  6. Cone-beam volume CT breast imaging: Feasibility study

    International Nuclear Information System (INIS)

    Chen Biao; Ning Ruola

    2002-01-01

    X-ray projection mammography, using a film/screen combination, or digital techniques, has proven to be the most effective imaging modality currently available for early detection of breast cancer. However, the inherent superimposition of structures makes a small carcinoma (a few millimeters in size) difficult to detect when it is occult or in dense breasts, leading to a high false-positive biopsy rate. Cone-beam x-ray-projection-based volume imaging using flat panel detectors (FPDs) may allow obtaining three-dimensional breast images, resulting in more accurate diagnosis of structures and patterns of lesions while eliminating the hard compression of breasts. This article presents a novel cone-beam volume computed tomographic breast imaging (CBVCTBI) technique based on the above techniques. Through a variety of computer simulations, the key issues of the system and imaging techniques were addressed, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissue and lesions, x-ray setting techniques, the absorbed dose estimation, and the quantitative effect of x-ray scattering on image quality. The preliminary simulation results support the proposed CVBCTBI modality for breast imaging in respect to its feasibility and practicability. The absorbed dose level is comparable to that of current mammography and will not be a prominent problem for this imaging technique. Compared to conventional mammography, the proposed imaging technique with isotropic spatial resolution will potentially provide significantly better low-contrast detectability of breast tumors and more accurate location of breast lesions

  7. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  8. False Memories for Shape Activate the Lateral Occipital Complex

    Science.gov (United States)

    Karanian, Jessica M.; Slotnick, Scott D.

    2017-01-01

    Previous functional magnetic resonance imaging evidence has shown that false memories arise from higher-level conscious processing regions rather than lower-level sensory processing regions. In the present study, we assessed whether the lateral occipital complex (LOC)--a lower-level conscious shape processing region--was associated with false…

  9. Radiodine administration under suppression of TSH for identification of false positive receptions in patients with thyroid differentiated carcinoma (TDC): utility of the potassium perchlorate

    International Nuclear Information System (INIS)

    Santangelo, L.A.; Pitoia, F.; Sanz, C.; Niepomniszcze, H.; El Tamer, Elias

    2004-01-01

    The total body scan, after a dose of 131 I correlated with the measurement of stimulated Tg, constitute the principal pillars in follow-up of patients with TDC (thyroid differentiated carcinoma). A bibliographical search revealed more than 70 situations that can cause false total body scans positive. The examination is essential to avoid unnecessary treatment with radioiodine. The object is to evaluate the effectiveness of the radioiodine administration under hormonal therapy thyroid suppressive (THST) to eliminate the possibility of a false total body scan positive in five patients with TDC with stimulated Tg <1ng/ml

  10. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    International Nuclear Information System (INIS)

    Vilanova, J.C.; Barcelo, J.; Comet, J.; Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E.; Barcelo, C.

    2001-01-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year -1 ). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging. (orig.)

  11. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Vilanova, J.C.; Barcelo, J. [Ressonancia Girona, Clinica Girona, Girona (Spain); Comet, J. [Dept. of Urology, Univ. Hospital of Girona (Spain); Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E. [Centre Diagnostic Pedralbes, Cetir Grup Medic, Barcelona (Spain); Barcelo, C. [Dept. of Computer Science and Applied Mathematics, University of Girona (Spain)

    2001-02-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year{sup -1}). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging

  12. Object position and image magnification in dental panoramic radiography: a theoretical analysis.

    Science.gov (United States)

    Devlin, H; Yuan, J

    2013-01-01

    The purpose of our study was to investigate how image magnification and distortion in dental panoramic radiography are influenced by object size and position for a small round object such as a ball bearing used for calibration. Two ball bearings (2.5 mm and 6 mm in diameter) were placed at approximately the same position between the teeth of a plastic skull and radiographed 21 times. The skull was replaced each time. Their images were measured by software using edge detection and ellipse-fitting algorithms. Using a standard definition of magnification, equations were derived to enable an object's magnification to be determined from its position and vice versa knowing the diameter and machine parameters. The average magnification of the 2.5 mm ball bearing was 1.292 (0.0445) horizontally and 1.257 (0.0067) vertically with a mean ratio of 1.028 (0.0322); standard deviations are in parentheses. The figures for the 6 mm ball bearing were 1.286 (0.0068), 1.255 (0.0018) and 1.025 (0.0061), respectively. Derived positions of each ball bearing from magnification were more consistent horizontally than vertically. There was less variation in either direction for the 6 mm ball bearing than the 2.5 mm one. Automatic measurement of image size resulted in less variation in vertical magnification values than horizontal. There are only certain positions in the focal trough that achieve zero distortion. Object location can be determined from its diameter, measured magnification and machine parameters. The 6 mm diameter ball bearing is preferable to the 2.5 mm one for more reliable magnification measurement and position determination.

  13. A prospective study of computed tomography, ultrasound, and gallium imaging in patients with fever

    International Nuclear Information System (INIS)

    McNeil, B.J.; Sanders, R.; Alderson, P.O.; Hessel, S.J.; Finberg, H.; Siegelman, S.S.; Adams, D.F.; Abrams, H.L.

    1981-01-01

    Computed tomography, ultrasound, and 67 Ga-citrate imaging were analyzed prospectively in patients thought to have a focal source of sepsis. They were divided into three groups: (a) postoperative, fever greater than or equal to 38.3 degrees C; (b) fever greater than or equal to 38.3 degrees C for less than four weeks, unrelated to surgery; and (c) any fever present for more than four weeks. ROC curves showed no significant difference in the ability of the three modalities to differentiate focal from nonfocal sources of sepsis. If any two examinations were used and either study was abnormal, the sensitivity increased from about 60% to nearly 90% while the false-positive rate increased from about 15% to 25%. When focal disease was diagnosed only if two examinations were abnormal, the false-positive ratio dropped to nearly zero but the sensitivity fell to below 40%. The authors concluded tha all three modalities have a similar ability to detect sepsis and that sensitivity can be increased by using any two of them

  14. The Lifetime Economic Burden of Inaccurate HER2 Testing: Estimating the Costs of False-Positive and False-Negative HER2 Test Results in US Patients with Early-Stage Breast Cancer.

    Science.gov (United States)

    Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa

    2015-06-01

    Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. Uptake of 131-I in maxillary bones mimicking salivary glands. False- positive images in patients with differentiated thyroid carcinoma (DTC )

    International Nuclear Information System (INIS)

    Degrossi, Osvaldo J.; Degrossi, E.B.; Levi de Cabrejas, Mariana

    2008-01-01

    In the whole body scans (WBS) with 131-I in the follow-up or treatment of patients bearing DTC it is observed frequently fixation areas of the tracer apparently in relation with salivary glands. These areas generally belong to the salivary glands and are present during the first 48/72 hours, but others are kept during more than 3 weeks. These latter ones were considered as possible uptake in ectopic thyroid cells in the mouth floor, iodized proteins, retention of salivary glands and other assertions. Valdivieso et al. (Cong. Arg. Biol. Med. Nuclear, 1996) and Gutierrez et al. (SLAT,Chile, 1997) considered that the fixation took place also in maxillary bones probably in areas in relation with dental illness (inflammation, pulpitis, dental caries, perionditis, periapical granuloma, periapical cyst and resorption of surrounding bone seen radiologically as periapical radiolucency). This presumption was sustained for two publications (Clin. Nucl. Med. 1998;23. 747-749, and Clin. Nucl. Med. 2000; 23; 314-315). This end the review of 638 131-I WBS carried out between January 1st, 2002 and December 31st of 2007 in 502 patients that were studied for ablation, treatment of metastasis or relapses or follow up. In 31,5% of the patients were observed areas of activity in maxilla. The intensity of concentration of the tracer was 0.3 to 1.2 % of the activity administered. In 10 patients was determinate the effective T 1/2 and in 5 a panoramic Rx of the maxilla and a bone scintigraphy with 99m-Tc-MDP; there were correlation between both images, the 131-I one an the 99m-Tc-MDP with radiology. The effective T 1/2 mean value was 6,87 days ± 0,94 (S.D.) very close to the physical T 1/2 of the radioiodine tracer indicating a strongly labeled molecule. In 6 patients treated with high activities of radioiodine (5,55 to 11,1 MBq - 150 to 300 mCi) actinic lesions were observed in mouth and lingual mucous membrane, including ulcers. The intensity of the images and of the lesions correlate

  16. Confabulation versus experimentally induced false memories in Korsakoff patients.

    Science.gov (United States)

    Van Damme, Ilse; d'Ydewalle, Géry

    2010-09-01

    The present study focuses on both the clinical symptom of confabulation and experimentally induced false memories in patients suffering from Korsakoff's syndrome. Despite the vast amount of case studies of confabulating patients and studies investigating false memories in the Deese-Roediger-McDermott (DRM) paradigm, the nature of Korsakoff patients' confabulatory behaviour and its association with DRM false memories have been rarely examined. Hence, the first aim of the present study was to evaluate confabulatory responses in a large sample of chronic Korsakoff patients and matched controls by means of the Dalla Barba Confabulation Battery. Second, the association between (provoked) confabulation and the patients' DRM false recognition performance was investigated. Korsakoff patients mainly confabulated in response to questions about episodic memory and questions to which the answer was unknown. A positive association was obtained between confabulation and the tendency to accept unstudied distractor words as being old in the DRM paradigm. On the other hand, there was a negative association between confabulation and false recognition of critical lures. The latter could be attributed to the importance of strategic retrieval at delayed memory testing.

  17. 5 Ways to Promote a Positive Body Image for Kids

    Science.gov (United States)

    ... physical activity. In contrast, kids with a negative body image feel more self-conscious, anxious and isolated. They are at greater risk for excessive weight gain and for eating disorders. Give your child the gift of positive body image and help prevent these problems — take the following ...

  18. Chronic bacterial osteomyelitis: prospective comparison of 18F-FDG imaging with a dual-head coincidence camera and 111In-labelled autologous leucocyte scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Siefker, U.; Lehmann, K.; Meyer, I.; Schreiber, K.; Altenvoerde, G.; Becker, W.; Liersch, T.

    2002-01-01

    Indium-111-labelled white blood cells ( 111 In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [ 18 F]2'-deoxy-2-fluoro-D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and 111 In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), 111 In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. 111 In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology (n=17) or culture (n=1), 111 In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology (n=18) or culture (n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG

  19. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  20. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  1. Statistical Study of False Alarms of Geomagnetic Storms

    DEFF Research Database (Denmark)

    Leer, Kristoffer; Vennerstrøm, Susanne; Veronig, A.

    . A subset of these halo CMEs did not cause a geomagnetic storm the following four days and have therefore been considered as false alarms. The properties of these events are investigated and discussed here. Their statistics are compared to the geo-effective CMEs. The ability to identify potential false......Coronal Mass Ejections (CMEs) are known to cause geomagnetic storms on Earth. However, not all CMEs will trigger geomagnetic storms, even if they are heading towards the Earth. In this study, front side halo CMEs with speed larger than 500 km/s have been identified from the SOHO LASCO catalogue...

  2. False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.

    Science.gov (United States)

    Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed

    2017-10-01

    To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.

  3. Disfluent presentations lead to the creation of more false memories.

    Science.gov (United States)

    Sanchez, Christopher A; Naylor, Jamie S

    2018-01-01

    The creation of false memories within the Deese-Roediger-McDermott (DRM) paradigm has been shown to be sensitive to many factors such as task instructions, participant mood, or even presentation modality. However, do other simple perceptual differences also impact performance on the DRM and the creation of false memories? This study explores the potential impact of changes in perceptual disfluency on DRM performance. To test for a potential influence of disfluency on false memory creation, participants viewed lists under either perceptually disfluent conditions or not. Results indicated that disfluency did significantly impact performance in the DRM paradigm; more disfluent presentations significantly increased the recall and recognition of unpresented information, although they did not impact recall or recognition of presented information. Thus, although disfluency did impact performance, disfluency did not produce a positive benefit related to overall task performance. This finding instead suggests that more disfluent presentations can increase the likelihood that false memories are created, and provide little positive performance benefit.

  4. Prona positioning in patients submitted to myocardial perfusion scintigraphy; Posicao prona em pacientes submetidos a cintilografia de perfusao miocardica

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, C.J.; Ferreira, F.C.L.; Dullius, M.A.; Souza, S.O.; Souza, D.N. [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Dept. de Fisica; Carvalho, C.R.A. [Clinica de Medicina Nuclear Endocrinologia e Diabetes, Aracaju, SE (Brazil)

    2011-10-26

    The myocardium perfusion scintigraphy corresponds at the nuclear medicine to one of best diagnostic methods for myocardium diseases. However, artefacts generated by the diaphragmatic tissue can induce to false positive diagnostic when does not occurs association of the image in supine position with the prone position. Images acquired at the two positions were analysed and the evaluation of tomographic images were estimation and consequently, a more completed diagnostic

  5. Color feature extraction of HER2 Score 2+ overexpression on breast cancer using Image Processing

    Directory of Open Access Journals (Sweden)

    Muhimmah Izzati

    2018-01-01

    Full Text Available One of the major challenges in the development of early diagnosis to assess HER2 status is recognized in the form of Gold Standard. The accuracy, validity and refraction of the Gold Standard HER2 methods are widely used in laboratory (Perez, et al., 2014. Method determining the status of HER2 (human epidermal growth factor receptor 2 is affected by reproductive problems and not reliable in predicting the benefit from anti-HER2 therapy (Nuciforo, et al., 2016. We extracted color features by methods adopting Statistics-based segmentation using a continuous-scale naïve Bayes approach. In this study, there were three parts of the main groups, namely image acquisition, image segmentation, and image testing. The stages of image acquisition consisted of image data collection and color deconvolution. The stages of image segmentation consisted of color features, classifier training, classifier prediction, and skeletonization. The stages of image testing were image testing, expert validation, and expert validation results. Area segmentation of the membrane is false positive and false negative. False positive and false negative from area are called the area of system failure. The failure of the system can be validated by experts that the results of segmentation region is not membrane HER2 (noise and the segmentation of the cytoplasm region. The average from 40 data of HER2 score 2+ membrane images show that 75.13% of the area is successfully recognized by the system.

  6. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Ronot, Maxime; Vilgrain, Valerie; Beers, Bernard E. van [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique- Hopitaux de Paris, Laboratory of Physiological and Molecular Imaging of the Abdomen (IPMA) and Department of Radiology, Clichy Cedex (France); Maggiori, Leon; Panis, Yves [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Colorectal Surgery, Clichy (France); Paradis, Valerie [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Pathology, Clichy (France)

    2013-08-15

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm{sup 2}) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P {<=} 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. (orig.)

  7. The “Facebook-self”: characteristics and psychological predictors of false self-presentation on Facebook

    Science.gov (United States)

    Gil-Or, Oren; Levi-Belz, Yossi; Turel, Ofir

    2015-01-01

    In this study we present and empirically examine a new phenomenon related to social networking sites, such as Facebook, the “false Facebook-self.” Arguably false self-presentation on Facebook is a growing phenomenon, and in extreme cases; i.e., when ones Facebook image substantially deviates from their true image, it may serve as a gateway behavior to more problematic behaviors which may lead to psychological problems and even pathologies. In this study we show that certain users are more vulnerable to such false self-presentation than others. The study involved 258 Facebook users. Applying ANOVA and SEM analyses we show that users with low self-esteem and low trait authenticity are more likely than others to present a Facebook-self which deviates from their true selves. These social-interaction-related traits are influenced by one’s upbringing and the anxious and avoidant attachment styles he or she has developed. Several cases (7.5%) with large gaps between the true and false Facebook-self were detected, which implies that future research should consider the adverse consequences and treatments of high levels of false Facebook-self. PMID:25741299

  8. The “Facebook-self”: characteristics and psychological predictors of false self-presentation on Facebook

    Directory of Open Access Journals (Sweden)

    Oren Gil-Or

    2015-02-01

    Full Text Available In this study we present and empirically examine a new phenomenon related to social networking sites, such as Facebook, the “false Facebook-self.” Arguably false self-presentation on Facebook is a growing phenomenon, and in extreme cases; i.e., when ones Facebook image substantially deviates from their true image, it may serve as a gateway behavior to more problematic behaviors which may lead to psychological problems and even pathologies. In this study we show that certain users are more vulnerable to such false self-presentation than others. The study involved 258 Facebook users. Applying ANOVA and SEM analyses we show that users with low self-esteem and low trait authenticity are more likely than others to present a Facebook-self which deviates from their true selves. These social-interaction-related traits are influenced by one’s upbringing and the anxious and avoidant attachment styles he or she has developed. Several cases (7.5% with large gaps between the true and false Facebook-self were detected, which implies that future research should consider the adverse consequences and treatments of high levels of false Facebook-self.

  9. Improved accuracy of cell surface shaving proteomics in Staphylococcus aureus using a false-positive control

    DEFF Research Database (Denmark)

    Solis, Nestor; Larsen, Martin Røssel; Cordwell, Stuart J

    2010-01-01

    Proteolytic treatment of intact bacterial cells is an ideal means for identifying surface-exposed peptide epitopes and has potential for the discovery of novel vaccine targets. Cell stability during such treatment, however, may become compromised and result in the release of intracellular proteins...... that complicate the final analysis. Staphylococcus aureus is a major human pathogen, causing community and hospital-acquired infections, and is a serious healthcare concern due to the increasing prevalence of multiple antibiotic resistances amongst clinical isolates. We employed a cell surface "shaving" technique...... to trypsin and three identified in the control. The use of a subtracted false-positive strategy improved enrichment of surface-exposed peptides in the trypsin data set to approximately 80% (124/155 peptides). Predominant surface proteins were those associated with methicillin resistance-surface protein SACOL...

  10. Incidental lung cancers and positive computed tomography images in people living with HIV

    DEFF Research Database (Denmark)

    Ronit, Andreas; Kristensen, Thomas; Klitbo, Ditte M.

    2017-01-01

    in 901 patients, including 113 at high risk for lung cancer. A positive image was found in 28 (3.1% of the entire cohort and 9.7% of the high-risk group). Nine patients (all in the high-risk group) had invasive procedures undertaken with no serious adverse events. Lung cancer (stages IA, IIA, and IIIA......Objective: Lung cancer screening with low-dose computed tomography (LDCT) of high-risk groups in the general population is recommended by several authorities. This may not be feasible in people living with HIV (PLWHIV) due to higher prevalence of nodules. We therefore assessed the prevalence...... of positive computed tomography (CT) images and lung cancers in PLWHIV. Design: The Copenhagen comorbidity in HIV infection (COCOMO) study is an observational, longitudinal cohort study. Single-round LDCT was performed with subsequent clinical follow-up (NCT02382822). Method: Outcomes included histology...

  11. Relative Panoramic Camera Position Estimation for Image-Based Virtual Reality Networks in Indoor Environments

    Science.gov (United States)

    Nakagawa, M.; Akano, K.; Kobayashi, T.; Sekiguchi, Y.

    2017-09-01

    Image-based virtual reality (VR) is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS) positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  12. RELATIVE PANORAMIC CAMERA POSITION ESTIMATION FOR IMAGE-BASED VIRTUAL REALITY NETWORKS IN INDOOR ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    M. Nakagawa

    2017-09-01

    Full Text Available Image-based virtual reality (VR is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  13. Novel imaging strategies for upper gastrointestinal tract cancers

    DEFF Research Database (Denmark)

    Mortensen, Michael Bau

    2015-01-01

    Accurate pretherapeutic imaging is the cornerstone of all cancer treatment. Unfortunately, modern imaging modalities have several unsolved problems and limitations. The differentiation between inflammation and cancer infiltration, false positive and false negative findings as well as lack...... of confirming biopsies in suspected metastases may have serious negative consequences in cancer patients. This review describes some of these problems and challenges the use of conventional imaging by suggesting new combined strategies that include selective use of confirming biopsies and complementary methods...

  14. Processing Distracting Non-face Emotional Images: No Evidence of an Age-Related Positivity Effect.

    Science.gov (United States)

    Madill, Mark; Murray, Janice E

    2017-01-01

    Cognitive aging may be accompanied by increased prioritization of social and emotional goals that enhance positive experiences and emotional states. The socioemotional selectivity theory suggests this may be achieved by giving preference to positive information and avoiding or suppressing negative information. Although there is some evidence of a positivity bias in controlled attention tasks, it remains unclear whether a positivity bias extends to the processing of affective stimuli presented outside focused attention. In two experiments, we investigated age-related differences in the effects of to-be-ignored non-face affective images on target processing. In Experiment 1, 27 older (64-90 years) and 25 young adults (19-29 years) made speeded valence judgments about centrally presented positive or negative target images taken from the International Affective Picture System. To-be-ignored distractor images were presented above and below the target image and were either positive, negative, or neutral in valence. The distractors were considered task relevant because they shared emotional characteristics with the target stimuli. Both older and young adults responded slower to targets when distractor valence was incongruent with target valence relative to when distractors were neutral. Older adults responded faster to positive than to negative targets but did not show increased interference effects from positive distractors. In Experiment 2, affective distractors were task irrelevant as the target was a three-digit array and did not share emotional characteristics with the distractors. Twenty-six older (63-84 years) and 30 young adults (18-30 years) gave speeded responses on a digit disparity task while ignoring the affective distractors positioned in the periphery. Task performance in either age group was not influenced by the task-irrelevant affective images. In keeping with the socioemotional selectivity theory, these findings suggest that older adults preferentially

  15. Sample Size Calculation for Controlling False Discovery Proportion

    Directory of Open Access Journals (Sweden)

    Shulian Shang

    2012-01-01

    Full Text Available The false discovery proportion (FDP, the proportion of incorrect rejections among all rejections, is a direct measure of abundance of false positive findings in multiple testing. Many methods have been proposed to control FDP, but they are too conservative to be useful for power analysis. Study designs for controlling the mean of FDP, which is false discovery rate, have been commonly used. However, there has been little attempt to design study with direct FDP control to achieve certain level of efficiency. We provide a sample size calculation method using the variance formula of the FDP under weak-dependence assumptions to achieve the desired overall power. The relationship between design parameters and sample size is explored. The adequacy of the procedure is assessed by simulation. We illustrate the method using estimated correlations from a prostate cancer dataset.

  16. Mapping of the image quality in myocardial scintigraphy: A national study

    International Nuclear Information System (INIS)

    Ohlson, Maria; Gustafsson, Agnetha; Gretarsdottir, Jakobina; Olsson, Eva; Johansson, Lena

    2008-04-01

    The aim of this study was to make a survey over the physical parameters and how they affect the image quality and the final diagnosis for myocardial perfusion SPECT in Sweden. Another aim was to evaluate the need for standardized acquisition and processing protocols for myocardial perfusion SPECT. All thirty nuclear medicine departments in Sweden that perform myocardial perfusion SPECT participated in the study. A thorax heart phantom was used to simulate two patients. All studies were acquired and processed with the parameters used clinically in each hospital respectively. A quantitative and a qualitative evaluation were performed. At each hospital, the local nuclear medicine physician interpreted the images as if they were true patient images. There are great differences in the acquiring and processing parameters used in myocardial perfusion SPECT studies in Sweden. The image quality varies greatly for the different hospital but was approved for the majority of the hospitals. Images from two hospitals were considered to be too poor to be diagnosed. The interpretations of the local nuclear medicine physicians differ but the majority has reported an adequate diagnosis. One third of the hospitals have reported false positive defects. All steps in the chain from the acquisition to the evaluation of the medicine physician must be performed with high quality. The determinative factors are the noise reduction filter, the orientation of the slices in the heart and the judgement of the local medicine physician. The acquiring and processing parameters proposed by EANM should be used. The hospitals are also recommended to investigate in the time and resources available, in order to educate all staff involved in the evaluation of myocardial studies

  17. The False Premises and False Promises of the Movement to Privatize Public Education.

    Science.gov (United States)

    Hawley, Willis D.

    1995-01-01

    Argues that the movement to provide parents with financial incentives to send students to private schools will increase the racial, ethnic, and socioeconomic homogeneity of American schools. Six common assumptions about the positive effects of privatizing education are examined and deemed false. Probable costs of tuition vouchers for private…

  18. Genetic Imaging of the Association of Oxytocin Receptor Gene (OXTR Polymorphisms with Positive Maternal Parenting

    Directory of Open Access Journals (Sweden)

    Kalina J. Michalska

    2014-02-01

    Full Text Available Background: Well-validated models of maternal behavior in small-brain mammals posit a central role of oxytocin in parenting, by reducing stress and enhancing the reward value of social interactions with offspring. In contrast, human studies are only beginning to gain insights into how oxytocin modulates maternal behavior and affiliation. Methods: To explore associations between oxytocin receptor genes and maternal parenting behavior in humans, we conducted a genetic imaging study of women selected to exhibit a wide range of observed parenting when their children were 4-6 years old. Results: In response to child stimuli during functional magnetic resonance imaging, hemodynamic responses in brain regions that mediate affect, reward, and social behavior were significantly correlated with observed positive parenting. Furthermore, single nucleotide polymorphisms (rs53576 and rs1042778 in the gene encoding the oxytocin receptor were significantly associated with both positive parenting and hemodynamic responses to child stimuli in orbitofrontal cortex, anterior cingulate cortex and hippocampus. Conclusions: These findings contribute to the emerging literature on the role of oxytocin in human social behavior and support the feasibility of tracing biological pathways from genes to neural regions to positive maternal parenting behaviors in humans using genetic imaging methods.

  19. THE USE OF PUBLIC RELATIONS IN PROJECTING AN ORGANIZATION'S POSITIVE IMAGE

    Directory of Open Access Journals (Sweden)

    Ioana Olariu

    2017-07-01

    Full Text Available This article is a theoretical approach on the importance of using public relations in helping an organization to project a positive image. The study of the impact information has on the image of organisations seems to be an interesting research topic. Practice has proved that the image of institutions has a patrimonial value and it is sometimes essential in raising their credibility. It can be said that an image is defined as the representation of certain attitudes, opinions or prejudices concerning a person, a group of persons or the public opinion concerning an institution. In other words, an image is the opinion of a person, of a group of persons or of the public opinion regarding that institution. All specialists agree that a negative image affects, sometimes to an incredible extent, the success of an institution. In the contemporary age, we cannot speak about public opinion without taking into consideration the mass media as a main agent in transmitting the information to the public, with unlimited possibilities of influencing or forming it. The plan for the PR department starts with its own declaration of principles, which describes its roles and contribution to the organisation.

  20. Design of a Single-Cell Positioning Controller Using Electroosmotic Flow and Image Processing

    Directory of Open Access Journals (Sweden)

    Jhong-Yin Chen

    2013-05-01

    Full Text Available The objective of the current research was not only to provide a fast and automatic positioning platform for single cells, but also improved biomolecular manipulation techniques. In this study, an automatic platform for cell positioning using electroosmotic flow and image processing technology was designed. The platform was developed using a PCI image acquisition interface card for capturing images from a microscope and then transferring them to a computer using human-machine interface software. This software was designed by the Laboratory Virtual Instrument Engineering Workbench, a graphical language for finding cell positions and viewing the driving trace, and the fuzzy logic method for controlling the voltage or time of an electric field. After experiments on real human leukemic cells (U-937, the success of the cell positioning rate achieved by controlling the voltage factor reaches 100% within 5 s. A greater precision is obtained when controlling the time factor, whereby the success rate reaches 100% within 28 s. Advantages in both high speed and high precision are attained if these two voltage and time control methods are combined. The control speed with the combined method is about 5.18 times greater than that achieved by the time method, and the control precision with the combined method is more than five times greater than that achieved by the voltage method.

  1. Increased accuracy of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy using iterative reconstruction of images

    Directory of Open Access Journals (Sweden)

    Stević Miloš

    2016-01-01

    Full Text Available Background/Aim. Filtered back projection (FBP is a common way of processing myocardial perfusion imaging (MPI studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG, 77 man and 30 woman, aged 32−82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01 and between IR and CAG 0.784 (p < 0.01. The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01. Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  2. Can imaging criteria distinguish enchondroma from grade 1 chondrosarcoma?

    Science.gov (United States)

    Crim, Julia; Schmidt, Robert; Layfield, Lester; Hanrahan, Christopher; Manaster, Betty Jean

    2015-11-01

    To minimize systematic bias and optimize agreement on imaging criteria in order to better define the accuracy of imaging criteria in the diagnosis of grade 1 chondrosarcoma. Study was IRB-approved and HIPAA compliant; informed consent was waived. Records were reviewed and disclosed 53 cases (38 women, 15 men ages 21-76) which were diagnosed as enchondroma or grade 1 chondrosarcoma and had available radiographs, contrast-enhanced MRI, and definitive diagnosis by histology or 5-year follow-up. 2 MSK radiologists read the studies independently after a session where they agreed on criteria for malignancy. Interobserver variability was determined as raw variability and with the kappa statistic. Accuracy was determined compared to final diagnosis. Reliability of imaging features of chondrosarcoma was determined using regression analysis. The correct diagnosis of enchondroma was made on radiographs in 43 (67.2%) of readings, and on MRI in 37/64 (57.8%). The correct diagnosis of chondrosarcoma was made on radiographs in 5/24 (20.8%) of readings, and on MRI in 14/24 (57.8%). A diagnosis of borderline lesion was made in 19/64 (29.7%) of enchondromas on radiographs and 18/64 (28.1%) on MRI. The false positive rate of radiographs for chondrosarcoma was 2/64 (3.1%) and the false positive rate of MRI was 9/64 (14.1%). There was substantial interobserver variability. Cortical thickening and bone expansion were rare but specific signs of chondrosarcoma. Both radiographs and MRI have limitations in the evaluation of low-grade cartilage lesions. MRI has an increased rate of both true-positive and false-positive diagnosis compared to radiographs. Differences in the findings of this study compared to previous literature may reflect the influence of systematic biases. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. False positive results using calcitonin as a screening method for medullary thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Rafael Loch Batista

    2013-01-01

    Full Text Available The role of serum calcitonin as part of the evaluation of thyroid nodules has been widely discussed in literature. However there still is no consensus of measurement of calcitonin in the initial evaluation of a patient with thyroid nodule. Problems concerning cost-benefit, lab methods, false positive and low prevalence of medullary thyroid carcinoma (MTC are factors that limit this approach. We have illustrated two cases where serum calcitonin was used in the evaluation of thyroid nodule and rates proved to be high. A stimulation test was performed, using calcium as secretagogue, and calcitonin hyper-stimulation was confirmed, but anatomopathologic examination did not evidence medullar neoplasia. Anatomopathologic diagnosis detected Hashimoto thyroiditis in one case and adenomatous goiter plus an occult papillary thyroid carcinoma in the other one. Recommendation for routine use of serum calcitonin in the initial diagnostic evaluation of a thyroid nodule, followed by a confirming stimulation test if basal serum calcitonin is showed to be high, is the most currently recommended approach, but questions concerning cost-benefit and possibility of diagnosis error make the validity of this recommendation discussible.

  4. Forming positive-negative images using conditioned partial measurements from reference arm in ghost imaging.

    Science.gov (United States)

    Wen, Jianming

    2012-09-01

    A recent thermal ghost imaging experiment implemented in Wu's group [Chin. Phys. Lett. 279, 074216 (2012)] showed that both positive and negative images can be constructed by applying a novel algorithm. This algorithm allows us to form the images with the use of partial measurements from the reference arm (even which never passes through the object), conditioned on the object arm. In this paper, we present a simple theory that explains the experimental observation and provides an in-depth understanding of conventional ghost imaging. In particular, we theoretically show that the visibility of formed images through such an algorithm is not bounded by the standard value 1/3. In fact, it can ideally grow up to unity (with reduced imaging quality). Thus, the algorithm described here not only offers an alternative way to decode spatial correlation of thermal light, but also mimics a "bandpass filter" to remove the constant background such that the visibility or imaging contrast is improved. We further show that conditioned on one still object present in the test arm, it is possible to construct the object's image by sampling the available reference data.

  5. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 3. Apparent discrepancies between LLNA and GPMT sensitisation potential: False positives or differences in sensitivity?

    Science.gov (United States)

    Roberts, David W; Schultz, Terry W; Api, Anne Marie

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Attributions, false consensus and valence: two field studies

    NARCIS (Netherlands)

    van der Pligt, J.

    1984-01-01

    Two studies, with 1,056 Ss, investigated attitudes, knowledge, and behavior with regard to several environmental issues. Findings demonstrate that observers tend to perceive a false consensus with respect to the relative commonness of their own behavioral choices. This phenomenon was replicated

  7. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Igel, Todd C.; Gale, Ashley A.; Serago, Nicole E.; Earle, John D.

    2006-01-01

    Purpose: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. Methods and Materials: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. Results: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 ± 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 ± 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 ± 3.1 mm, and the average intrafraction movement during treatment is 3.4 ± 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 ± 1.5 mm, and the average intrafraction movement during treatment is 2.1 ± 1.5 mm. Conclusions: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization

  8. False memory in aging: effects of emotional valence on word recognition accuracy.

    Science.gov (United States)

    Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne

    2008-06-01

    Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.

  9. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  10. Next-generation sequencing indicates false-positive MRD results and better predicts prognosis after SCT in patients with childhood ALL.

    Science.gov (United States)

    Kotrova, M; van der Velden, V H J; van Dongen, J J M; Formankova, R; Sedlacek, P; Brüggemann, M; Zuna, J; Stary, J; Trka, J; Fronkova, E

    2017-07-01

    Minimal residual disease (MRD) monitoring via quantitative PCR (qPCR) detection of Ag receptor gene rearrangements has been the most sensitive method for predicting prognosis and making post-transplant treatment decisions for patients with ALL. Despite the broad clinical usefulness and standardization of this method, we and others have repeatedly reported the possibility of false-positive MRD results caused by massive B-lymphocyte regeneration after stem cell transplantation (SCT). Next-generation sequencing (NGS) enables precise and sensitive detection of multiple Ag receptor rearrangements, thus providing a more specific readout compared to qPCR. We investigated two cohorts of children with ALL who underwent SCT (30 patients and 228 samples). The first cohort consisted of 17 patients who remained in long-term CR after SCT despite having low MRD positivity (SCT monitoring using qPCR. Only one of 27 qPCR-positive samples was confirmed to be positive by NGS. Conversely, 10 of 15 samples with low qPCR-detected MRD positivity from 13 patients who subsequently relapsed were also confirmed to be positive by NGS (P=0.002). These data show that NGS has a better specificity in post-SCT ALL management and indicate that treatment interventions aimed at reverting impending relapse should not be based on qPCR only.

  11. Mixing of multi-modal images for conformational radiotherapy: application to patient re positioning

    International Nuclear Information System (INIS)

    Vassal, P.

    1998-01-01

    This study shows a procedure of patient re positioning by comparative evaluation between the position of the patient and the theoretical expected position of the patient; the stagger between the two information gives the error of installation in translation and rotation. A correction is calculated and applied to the treatment environment (position and orientation of the patient, position and orientation of the irradiation source). The control system allows to determine the precise position of the tumor volume. The echography allows to determine the position of an organ.The surface captor is used to localize the tumors of the face or of the brain, with the respect to the face, the acquisition and the treatment of information take only few minutes. The X rays imager is applied for the localization of bones structures. (N.C.)

  12. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    International Nuclear Information System (INIS)

    Qiu, J; Yang, D

    2015-01-01

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  13. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J [Washington University in St Louis, Taian, Shandong (China); Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2015-06-15

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  14. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  15. Myositis ossificans: a false positive of malignancy in PET - CT F.D.G. and in osseous scintigraphy with HMDP 99Tc

    International Nuclear Information System (INIS)

    Hassler, S.; Bourahla, K.

    2010-01-01

    Myositis ossificans is a difficult differential diagnosis and a false positive for malignancy in both 99m Tc H.M.D.P. (hydroxy-methylene diphosphonate) scintigraphy and in exploration PET-F.D.G. This hypothesis should be mentioned in case of young patients, despite the unusual scintigraphic appearance in a benign process. (N.C.)

  16. A review of 99mTc labeled myocardial imaging agents for tumor-positive imaging

    International Nuclear Information System (INIS)

    Xing Shian; Zhang Yongxue; An Rui

    2002-01-01

    The tumor-positive imaging with high sensitivity and specificity was useful in primary tumor and recurrences and metastases. The 99m Tc labeled myocardial imaging agents are easily available and stable and the radiochemical purity is high. 99m Tc is the preferred choice in routine works because its physical properties. The preparation, quality control, mechanism of accumulation and the clinical use of 99m Tc-sestamibi, 99m Tc-tetrofosmin, 99m Tc-furifosmin, and 99m Tc-N-NOET were reviewed

  17. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  18. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  19. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  20. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  1. Transient medial prefrontal perturbation reduces false memory formation.

    Science.gov (United States)

    Berkers, Ruud M W J; van der Linden, Marieke; de Almeida, Rafael F; Müller, Nils C J; Bovy, Leonore; Dresler, Martin; Morris, Richard G M; Fernández, Guillén

    2017-03-01

    Knowledge extracted across previous experiences, or schemas, benefit encoding and retention of congruent information. However, they can also reduce specificity and augment memory for semantically related, but false information. A demonstration of the latter is given by the Deese-Roediger-McDermott (DRM) paradigm, where the studying of words that fit a common semantic schema are found to induce false memories for words that are congruent with the given schema, but were not studied. The medial prefrontal cortex (mPFC) has been ascribed the function of leveraging prior knowledge to influence encoding and retrieval, based on imaging and patient studies. Here, we used transcranial magnetic stimulation (TMS) to transiently perturb ongoing mPFC processing immediately before participants performed the DRM-task. We observed the predicted reduction in false recall of critical lures after mPFC perturbation, compared to two control groups, whereas veridical recall and recognition memory performance remained similar across groups. These data provide initial causal evidence for a role of the mPFC in biasing the assimilation of new memories and their consolidation as a function of prior knowledge. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. False recognition in behavioural variant frontotemporal dementia and Alzheimer’s disease – disinhibition or amnesia?

    Directory of Open Access Journals (Sweden)

    Emma C Flanagan

    2016-07-01

    Full Text Available Episodic memory recall processes in Alzheimer’s disease (AD and behavioural variant frontotemporal dementia (bvFTD can be similarly impaired, whereas recognition performance is more variable. A potential reason for this variability could be false-positive errors made on recognition trials and whether these errors are due to amnesia per se or a general over-endorsement of recognition items regardless of memory. The current study addressed this issue by analysing recognition performance on the Rey Auditory Verbal Learning Test (RAVLT in 39 bvFTD, 77 AD and 61 control participants from two centres (India, Australia, as well as disinhibition assessed using the Hayling test. Whereas both AD and bvFTD patients were comparably impaired on delayed recall, bvFTD patients showed intact recognition performance in terms of the number of correct hits. However, both patient groups endorsed significantly more false-positives than controls, and bvFTD and AD patients scored equally poorly on a sensitivity index (correct hits - false-positives. Furthermore, measures of disinhibition were significantly associated with false positives in both groups, with a stronger relationship with false-positives in bvFTD. Voxel-based morphometry analyses revealed similar neural correlates of false positive endorsement across bvFTD and AD, with both patient groups showing involvement of prefrontal and Papez circuitry regions, such as medial temporal and thalamic regions, and a DTI analysis detected an emerging but non-significant trend between false positives and decreased fornix integrity in bvFTD only. These findings suggest that false-positive errors on recognition tests relate to similar mechanisms in bvFTD and AD, reflecting deficits in episodic memory processes and disinhibition. These findings highlight that current memory tests are not sufficient to accurately distinguish between bvFTD and AD patients.

  3. Comment on ''Perfect imaging with positive refraction in three dimensions''

    International Nuclear Information System (INIS)

    Merlin, R.

    2010-01-01

    Leonhardt and Philbin [Phys. Rev. A 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

  4. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  5. High prevalence of human anti-bovine IgG antibodies as the major cause of false positive reactions in two-site immunoassays based on monoclonal antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Koch, Claus; Jensen, Charlotte H

    2004-01-01

    were purified by protein G affinity chromatography from culture supernatant containing 10% (v/v) fetal calf serum (FCS). Human anti-animal IgG (bovine, mouse, horse, and swine) antibodies and human anti-bovine serum albumin antibodies were measured using an ELISA design, with direct bridging...... of the solid phase and biotinylated antigens. The false positive reactions were abolished by addition of 1% (v/v) bovine serum to the dilution buffer (DB). Human anti-bovine IgG antibodies (HABIA) were detected in 99 out of 104 sera from blood donors (50 females; 54 males). HABIA levels in male sera (n = 54......) were positively correlated to the false positive signals in the PP14 ELISA (r = 0.923; p detected in the donor sera, but levels and frequencies were lower compared to that of HABIA. Furthermore, HABIA were...

  6. Limited value of delayed radiothallium image in the diagnosis of nodular goiter

    International Nuclear Information System (INIS)

    Misaki, Takashi; Yagi, Kanji; Dokoh, Shigeharu; Koh, Toshikiyo; Shimbo, Shin-ichiro

    1991-01-01

    To test whether delayed thallium image can improve the diagnostic accuracy of thyroid tumor, we have reviewed 35 patients with cold nodules of proven histopathology. Early and delayed images were taken 10-20 min and 3-4 hr postinjection, respectively. In this study, a thyroid nodule was interpreted as malignant if it had normal or increased uptake on early scan and more residual radioactivity than paranodular tissue on delayed scan. In the eighteen patients who had carcinoma, a disappointing 44% false negative rate was observed. No significant difference was seen between retention-positive and negative cases in tumor size or histological type of cancer. Nor could any demographic bias explain the low sensitivity. Of the six false negatives, macroscopic cystic degeneration was seen in two cases, but tumors in the other four were grossly solid. Considering the histological heterogeneity often seen within a thyroid tumor, the portion with increased retention of radiothallium may be too small to be detected in the false negative cases. Furthermore, 3 false positive readings were obtained in 17 patients with benign conditions. We conclude that the contribution of the delayed thallium image was quite limited in predicting or ruling out malignancy in nodular goiters. (author)

  7. Too Good to be False : Nonsignificant Results Revisited

    NARCIS (Netherlands)

    Hartgerink, Chris H J; Wicherts, Jelte M.; Van Assen, M. A. L. M.

    2017-01-01

    Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST) is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant

  8. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong; Lee, In Sook; Lee, Seung Jun

    2012-01-01

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images

  9. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong [Pusan National Univ. Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook; Lee, Seung Jun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2012-09-15

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images.

  10. Detection of lymph node metastases with ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging in oesophageal cancer: a feasibility study

    Science.gov (United States)

    van der Jagt, E.J.; van Westreenen, H.L.; van Dullemen, H.M.; Kappert, P.; Groen, H.; Sietsma, J.; Oudkerk, M.; Plukker, J.Th.M.; van Dam, G.M.

    2009-01-01

    Abstract Aim: In this feasibility study we investigated whether magnetic resonance imaging (MRI) with ultrasmall superparamagnetic iron oxide (USPIO) can be used to identify regional and distant lymph nodes, including mediastinal and celiac lymph node metastases in patients with oesophageal cancer. Patients and methods: Ten patients with a potentially curative resectable cancer of the oesophagus were eligible for this study. All patients included in the study had positive lymph nodes on conventional staging (including endoscopic ultrasound, computed tomography and fluorodeoxyglucose-positron emission tomography). Nine patients underwent MRI + USPIO before surgery. Results were restricted to those patients who had both MRI + USPIO and histological examination. Results were compared with conventional staging and histopathologic findings. Results: One patient was excluded due to expired study time. Five out of 9 patients underwent an exploration; in 1 patient prior to surgery MRI + USPIO diagnosed liver metastases and in 3 patients an oesophageal resection was performed. USPIO uptake in mediastinal lymph nodes was seen in 6 out of 9 patients; in 3 patients non-malignant nodes were not visible. In total, 9 lymph node stations (of 6 patients) were separately analysed; 7 lymph node stations were assessed as positive (N1) on MRI+USPIO compared with 9 by conventional staging. According to histology findings, there was one false-positive and one false-negative result in MRI + USPIO. Also, conventional staging modalities had one false-positive and one false-negative result. MRI + USPIO had surplus value in one patient. Not all lymph node stations could be compared due to unforeseen explorations. No adverse effects occurred after USPIO infusion. Conclusion: MRI+USPIO identified the majority of mediastinal and celiac (suspect) lymph nodes in 9 patients with oesophageal cancer. MRI+USPIO could have an additional value in loco-regional staging; however, more

  11. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    Science.gov (United States)

    Majidi, Keivan; Li, Jun; Muehleman, Carol; Brankov, Jovan G.

    2014-04-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér-Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  12. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    International Nuclear Information System (INIS)

    Majidi, Keivan; Brankov, Jovan G; Li, Jun; Muehleman, Carol

    2014-01-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér–Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  13. Factors influencing fast low angle positive contrast steady-state free precession (FLAPS) magnetic resonance imaging

    International Nuclear Information System (INIS)

    Dharmakumar, Rohan; Koktzoglou, Ioannis; Li Debiao

    2007-01-01

    The presence of susceptibility-shifting media can lead to signal voids in magnetic resonance images. While signal voids have been traditionally used to detect such magnetic perturbers, selective magnetic resonance imaging of off-resonant spins surrounding susceptibility-shifted media allows for them to be visualized as hyper-intense (positive contrast) regions. These positive contrast methods can potentially improve the detection conspicuity of magnetic perturbers against regions that appear dark due to the absence of protons, such as air. Recently, a fast low angle positive contrast steady-state free precession (FLAPS) technique has been proposed as a positive contrast imaging method. This work systematically evaluates the contrast characteristics and acquisition strategies of FLAPS-based imaging from the standpoint of imaging parameters and physical properties of the magnetic perturbers. Results show that scan parameters (T R , flip angle, B 0 ), physical properties of the perturber (size and concentration of shift reagent) and the ratio of the relaxation constants (T 1 /T 2 ) of the medium are significant factors influencing the FLAPS-based positive contrast

  14. Association between disk position and degenerative bone changes of the temporomandibular joints: an imaging study in subjects with TMD.

    Science.gov (United States)

    Cortés, Daniel; Sylvester, Daniel Cortés; Exss, Eduardo; Marholz, Carlos; Millas, Rodrigo; Moncada, Gustavo

    2011-04-01

    The aim of this study was to determine the frequency and relationship between disk position and degenerative bone changes in the temporomandibular joints (TMJ), in subjects with internal derangement (ID). MRI and CT scans of 180 subjects with temporomandibular disorders (TMD) were studied. Different image parameters or characteristics were observed, such as disk position, joint effusion, condyle movement, degenerative bone changes (flattened, cortical erosions and irregularities), osteophytes, subchondral cysts and idiopathic condyle resorption. The present study concluded that there is a significant association between disk displacement without reduction and degenerative bone changes in patients with TMD. The study also found a high probability of degenerative bone changes when disk displacement without reduction is present. No association was found between TMD and condyle range of motion, joint effusion and/or degenerative bone changes. The following were the most frequent morphological changes observed: flattening of the anterior surface of the condyle; followed by erosions and irregularities of the joint surfaces; flattening of the articular surface of the temporal eminence, subchondral cysts, osteophytes; and idiopathic condyle resorption, in decreasing order.

  15. Axillary lymph node metastases in patients with breast carcinomas: assessment with nonenhanced versus uspio-enhanced MR imaging.

    Science.gov (United States)

    Memarsadeghi, Mazda; Riedl, Christopher C; Kaneider, Andreas; Galid, Arik; Rudas, Margaretha; Matzek, Wolfgang; Helbich, Thomas H

    2006-11-01

    To prospectively assess the accuracy of nonenhanced versus ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging for depiction of axillary lymph node metastases in patients with breast carcinoma, with histopathologic findings as reference standard. The study was approved by the university ethics committee; written informed consent was obtained. Twenty-two women (mean age, 60 years; range, 40-79 years) with breast carcinomas underwent nonenhanced and USPIO-enhanced (2.6 mg of iron per kilogram of body weight intravenously administered) transverse T1-weighted and transverse and sagittal T2-weighted and T2*-weighted MR imaging in adducted and elevated arm positions. Two experienced radiologists, blinded to the histopathologic findings, analyzed images of axillary lymph nodes with regard to size, morphologic features, and USPIO uptake. A third independent radiologist served as a tiebreaker if consensus between two readers could not be reached. Visual and quantitative analyses of MR images were performed. Sensitivity, specificity, and accuracy values were calculated. To assess the effect of USPIO after administration, signal-to-noise ratio (SNR) changes were statistically analyzed with repeated-measurements analysis of variance (mixed model) for MR sequences. At nonenhanced MR imaging, of 133 lymph nodes, six were rated as true-positive, 99 as true-negative, 23 as false-positive, and five as false-negative. At USPIO-enhanced MR imaging, 11 lymph nodes were rated as true-positive, 120 as true-negative, two as false-positive, and none as false-negative. In two metastatic lymph nodes in two patients with more than one metastatic lymph node, a consensus was not reached. USPIO-enhanced MR imaging revealed a node-by-node sensitivity, specificity, and accuracy of 100%, 98%, and 98%, respectively. At USPIO-enhanced MR imaging, no metastatic lymph nodes were missed on a patient-by-patient basis. Significant interactions indicating differences

  16. Evaluation of orthognathic surgery on articular disc position and temporomandibular joint symptoms in skeletal class II patients: A Magnetic Resonance Imaging study.

    Science.gov (United States)

    Firoozei, Gholamreza; Shahnaseri, Shirin; Momeni, Hasan; Soltani, Parisa

    2017-08-01

    The purpose of orthognathic surgery is to correct facial deformity and dental malocclusion and to obtain normal orofacial function. However, there are controversies of whether orthognathic surgery might have any negative influence on temporomandibular (TM) joint. The purpose of this study was to evaluate the influence of orthognathic surgery on articular disc position and temporomandibular joint symptoms of skeletal CI II patients by means of magnetic resonance imaging. For this purpose, fifteen patients with skeletal CI II malocclusion, aged 19-32 years (mean 23 years), 10 women and 5 men, from the Isfahan Department of Oral and Maxillofacial Surgery were studied. All received LeFort I and bilateral sagittal split osteotomy (BSSO) osteotomies and all patients received pre- and post-surgical orthodontic treatment. Magnetic resonance imaging was performed 1 day preoperatively and 3 month postoperatively. Descriptive statistics and Wilcoxon and Mc-Nemar tests were used for statistical analysis. P surgery (mean=5.74±1.21). After surgery disc position range was 4.36 to 7.40 (mean=5.65±1.06). Statistical analysis proved that although TM disc tended to move anteriorly after BSSO surgery, this difference was not statistically significant ( p valuesurgery does not alter the disc and condyle relationship. Therefore, it has minimal effects on intact and functional TM joint. Key words: Orthognathic surgery, skeletal class 2, magnetic resonance imaging, temporomandibular disc.

  17. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  18. Diffusion-weighted imaging (b value = 1500 s/mm(2)) is useful to decrease false-positive breast cancer cases due to fibrocystic changes.

    Science.gov (United States)

    Ochi, Miho; Kuroiwa, Toshiro; Sunami, Shunya; Murakami, Junji; Miyahara, Shinichiro; Nagaie, Takashi; Oya, Masafumi; Yabuuchi, Hidetake; Hatakenaka, Masamitsu

    2013-04-01

    We aimed to evaluate the application of apparent diffusion coefficient (ADC) values calculated from diffusion-weighted imaging (DWI) (b value = 1500 s/mm(2)) in the breast imaging reporting and data system (BI-RADS). For 104 cases of breast lesions with definitive histology diagnosis (45 benign cases, 59 malignant cases) in which breast magnetic resonance imaging was performed, ADC values were compared between benign and malignant cases, between ductal carcinoma in situ (DCIS) and fibrocystic changes, and between DCIS and ductal hyperplasia (one type of fibrocystic change). Diagnostic accuracy was compared for a total of 101 images and for 34 images including only nine DCIS and 25 fibrocystic changes between BI-RADS alone (with categories 4a, 4b, and 5 defined as malignancies) and BI-RADS plus ADC. There were significant differences in mean ADC values between malignant and benign cases (p fibrocystic changes (p fibrocystic changes (40.9% for BI-RADS alone, 64.3% for BI-RADS plus ADC), resulting in a significant improvement in diagnostic accuracy with the addition of ADC. Adding ADC values calculated from DWI (b value = 1500 s/mm(2)) to BI-RADS is a useful way to improve differential diagnostic accuracy for malignant tumors and benign lesions, especially for DCIS versus fibrocystic changes, except in cases of ductal hyperplasia.

  19. Staging primary breast cancer. Are there tumour pathological features that correlate with a false-negative axillary ultrasound?

    International Nuclear Information System (INIS)

    Johnson, S.; Brown, S.; Porter, G.; Steel, J.; Paisley, K.; Watkins, R.; Holgate, C.

    2011-01-01

    Aim: To investigate whether the histopathological characteristics of primary breast cancer tumours could predict the likelihood of false-negative axillary ultrasound. Materials and methods: Screening and symptomatic patients were identified from pathology records and imaging and pathology records reviewed. True and false-negative axillary staging ultrasound groups were compared statistically in terms of tumour size, pathological type and grade, lymphovascular invasion, and oestrogen receptor (ER) status. Results: Of 155 women with normal ultrasounds, 45 (29%) were node positive at axillary surgery. Breast tumour size was significantly different with the average size smaller in the true-negative group: 21 versus 30 mm (p < 0.02). The histological type varied significantly between the groups, with more lobular carcinomas in the false-negative group [6/110 (5%) versus 6/45 (13%), p < 0.001]. The false-negative group was also more likely to show lymphovascular invasion in the breast [6/110 (5%) versus 14/45 (31%), p < 0.001]. There was no significant difference in tumour grade or ER status. Conclusion: The present study has found significant differences in tumour characteristics between women with true-negative and false-negative axillary staging ultrasound in terms of size, primary tumour histological type and presence of lymphovascular invasion. In particular, axillary ultrasound in primary lobular carcinoma may be less accurate and a negative result is more likely to be spurious than with primary ductal carcinomas.

  20. Minimotif Miner 3.0: database expansion and significantly improved reduction of false-positive predictions from consensus sequences.

    Science.gov (United States)

    Mi, Tian; Merlin, Jerlin Camilus; Deverasetty, Sandeep; Gryk, Michael R; Bill, Travis J; Brooks, Andrew W; Lee, Logan Y; Rathnayake, Viraj; Ross, Christian A; Sargeant, David P; Strong, Christy L; Watts, Paula; Rajasekaran, Sanguthevar; Schiller, Martin R

    2012-01-01

    Minimotif Miner (MnM available at http://minimotifminer.org or http://mnm.engr.uconn.edu) is an online database for identifying new minimotifs in protein queries. Minimotifs are short contiguous peptide sequences that have a known function in at least one protein. Here we report the third release of the MnM database which has now grown 60-fold to approximately 300,000 minimotifs. Since short minimotifs are by their nature not very complex we also summarize a new set of false-positive filters and linear regression scoring that vastly enhance minimotif prediction accuracy on a test data set. This online database can be used to predict new functions in proteins and causes of disease.

  1. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension. Comparison with portographic findings of the pars umbilicus of the portal vein

    Energy Technology Data Exchange (ETDEWEB)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya [National Cancer Center, Tokyo (Japan). Hospital; Fukutake, Toshio

    1982-09-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH/sub 2/O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH/sub 2/O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered.

  2. Significance of FDG-PET in Identification of Diseases of the Appendix – Based on Experience of Two Cases Falsely Positive for FDG Accumulation

    Directory of Open Access Journals (Sweden)

    Shimpei Ogawa

    2009-04-01

    Full Text Available A discussion of the significance of F-fluorodeoxyglucose positron emission tomography (FDG-PET in the identification of diseases of the appendix is presented based on two cases falsely positive for FDG accumulation. Both cases were palpable for a tumor in the lower right abdominal region and a prominently enlarged appendix was depicted by CT. Although the patients underwent ileocecal resection based on a strong suspicion of appendiceal cancer rather than appendicitis since abnormal accumulation exhibiting maximum standard uptake values (SUVs of 7.27 and 17.11, respectively, was observed at the same site in FDG-PET examination and since there no malignant findings observed histologically, the patients were diagnosed with appendicitis. Although FDG specifically accumulates not only in malignant tumors, but also in diseases such as acute or chronic inflammation, abscesses and lymphadenitis, and identification based on SUVs has been reported to be used as a method of identification, the two cases reported here were both false-positive cases exhibiting high maximum SUVs. At the present time, although the significance of FDG-PET in the identification of diseases of the appendix is somewhat low and there are limitations on its application, various research is currently being conducted with the aim of improving diagnostic accuracy, and it is hoped that additional studies will be conducted in the future.

  3. Comment on ``Perfect imaging with positive refraction in three dimensions''

    Science.gov (United States)

    Merlin, R.

    2010-11-01

    Leonhardt and Philbin [Phys. Rev. APLRAAN1050-294710.1103/PhysRevA.81.011804 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

  4. Predicting body appreciation in young women: An integrated model of positive body image.

    Science.gov (United States)

    Andrew, Rachel; Tiggemann, Marika; Clark, Levina

    2016-09-01

    This study examined a range of predictors, based on previous theoretical models, of positive body image in young adult women. Participants were 266 women who completed an online questionnaire measuring body appreciation, activity participation, media consumption, perceived body acceptance by others, self-compassion, and autonomy. Potential mechanisms in predicting body appreciation assessed were self-objectification, social appearance comparison, and thin-ideal internalisation. Results indicated that greater perceived body acceptance by others and self-compassion, and lower appearance media consumption, self-objectification, social comparison, and thin-ideal internalisation were related to greater body appreciation. An integrated model showed that appearance media (negatively) and non-appearance media and self-compassion (positively) were associated with lower self-objectification, social comparison, and thin-ideal internalisation, which in turn related to greater body appreciation. Additionally, perceived body acceptance by others was directly associated with body appreciation. The results contribute to an understanding of potential pathways of positive body image development, thereby highlighting possible intervention targets. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Daily Prostate Volume and Position Monitoring Using Implanted Gold Markers and On-Board Imaging during Radiotherapy

    Directory of Open Access Journals (Sweden)

    Linda Kašaová

    2011-01-01

    Full Text Available Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy. Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

  6. Automatic discrimination of fine roots in minirhizotron images.

    Science.gov (United States)

    Zeng, Guang; Birchfield, Stanley T; Wells, Christina E

    2008-01-01

    Minirhizotrons provide detailed information on the production, life history and mortality of fine roots. However, manual processing of minirhizotron images is time-consuming, limiting the number and size of experiments that can reasonably be analysed. Previously, an algorithm was developed to automatically detect and measure individual roots in minirhizotron images. Here, species-specific root classifiers were developed to discriminate detected roots from bright background artifacts. Classifiers were developed from training images of peach (Prunus persica), freeman maple (Acer x freemanii) and sweetbay magnolia (Magnolia virginiana) using the Adaboost algorithm. True- and false-positive rates for classifiers were estimated using receiver operating characteristic curves. Classifiers gave true positive rates of 89-94% and false positive rates of 3-7% when applied to nontraining images of the species for which they were developed. The application of a classifier trained on one species to images from another species resulted in little or no reduction in accuracy. These results suggest that a single root classifier can be used to distinguish roots from background objects across multiple minirhizotron experiments. By incorporating root detection and discrimination algorithms into an open-source minirhizotron image analysis application, many analysis tasks that are currently performed by hand can be automated.

  7. Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials.

    Science.gov (United States)

    Houssami, Nehmat; Lång, Kristina; Bernardi, Daniela; Tagliafico, Alberto; Zackrisson, Sophia; Skaane, Per

    2016-04-01

    This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The position dependent influence that sensitivity correction processing gives the signal-to-noise ratio measurement in parallel imaging

    International Nuclear Information System (INIS)

    Murakami, Koichi; Yoshida, Koji; Yanagimoto, Shinichi

    2012-01-01

    We studied the position dependent influence that sensitivity correction processing gave the signal-to-noise ratio (SNR) measurement of parallel imaging (PI). Sensitivity correction processing that referred to the sensitivity distribution of the body coil improved regional uniformity more than the sensitivity uniformity correction filter with a fixed correction factor. In addition, the position dependent influence to give the SNR measurement in PI was different from the sensitivity correction processing. Therefore, if we divide SNR of the sensitivity correction processing image by SNR of the original image in each pixel and calculate SNR ratio, we can show the position dependent influence that sensitivity correction processing gives the SNR measurement in PI. It is with an index of the sensitivity correction processing precision. (author)

  9. Biased lineup instructions and face identification from video images.

    Science.gov (United States)

    Thompson, W Burt; Johnson, Jaime

    2008-01-01

    Previous eyewitness memory research has shown that biased lineup instructions reduce identification accuracy, primarily by increasing false-positive identifications in target-absent lineups. Because some attempts at identification do not rely on a witness's memory of the perpetrator but instead involve matching photos to images on surveillance video, the authors investigated the effects of biased instructions on identification accuracy in a matching task. In Experiment 1, biased instructions did not affect the overall accuracy of participants who used video images as an identification aid, but nearly all correct decisions occurred with target-present photo spreads. Both biased and unbiased instructions resulted in high false-positive rates. In Experiment 2, which focused on video-photo matching accuracy with target-absent photo spreads, unbiased instructions led to more correct responses (i.e., fewer false positives). These findings suggest that investigators should not relax precautions against biased instructions when people attempt to match photos to an unfamiliar person recorded on video.

  10. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Obenauer, S.; Hermann, K.P.

    2012-01-01

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  11. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.

    Science.gov (United States)

    Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M

    2017-02-01

    BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Image-Processing Scheme to Detect Superficial Fungal Infections of the Skin

    Directory of Open Access Journals (Sweden)

    Ulf Mäder

    2015-01-01

    Full Text Available The incidence of superficial fungal infections is assumed to be 20 to 25% of the global human population. Fluorescence microscopy of extracted skin samples is frequently used for a swift assessment of infections. To support the dermatologist, an image-analysis scheme has been developed that evaluates digital microscopic images to detect fungal hyphae. The aim of the study was to increase diagnostic quality and to shorten the time-to-diagnosis. The analysis, consisting of preprocessing, segmentation, parameterization, and classification of identified structures, was performed on digital microscopic images. A test dataset of hyphae and false-positive objects was created to evaluate the algorithm. Additionally, the performance for real clinical images was investigated using 415 images. The results show that the sensitivity for hyphae is 94% and 89% for singular and clustered hyphae, respectively. The mean exclusion rate is 91% for the false-positive objects. The sensitivity for clinical images was 83% and the specificity was 79%. Although the performance is lower for the clinical images than for the test dataset, a reliable and fast diagnosis can be achieved since it is not crucial to detect every hypha to conclude that a sample consisting of several images is infected. The proposed analysis therefore enables a high diagnostic quality and a fast sample assessment to be achieved.

  13. An fMRI study on the comparison of different types of false belief reasoning: False belief-based emotion and behavior attribution.

    Science.gov (United States)

    Döhnel, Katrin; Schuwerk, Tobias; Sodian, Beate; Hajak, Göran; Rupprecht, Rainer; Sommer, Monika

    2017-12-01

    False belief (FB) reasoning is a key Theory of Mind (ToM) competence. By 4 years of age, children understand that a person's behavior can be based on a FB about reality. Children cannot understand that a person's emotion can also be based on a FB before the age of six. In order to generate hypothesis on basic processes distinguishing these two types of belief reasoning, the present functional magnetic resonance imaging study in adults directly compares functional activity associated with these two FB tasks. Both tasks were associated with activity in the ToM network including the medial prefrontal cortex and the left temporo-parietal junction. Differential activity was observed in the anterior dorsolateral prefrontal cortex for FB-based emotion relative to behavior attribution. Contrary to FB behavior attribution, FB-based emotion attribution requires the processing of two different mental states: a belief and an emotion and their relation to each other. The activity pattern may reflect the differential demands on cognitive processes associated with the two different belief-based attribution processes. These results shed new light on the still ongoing debate about the nature of the developmental lag between the two FB tasks.

  14. False-positive I-131 scan by contaminated muffler in a patient with thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Han Kyung; Kim, Min Woo; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Hospital, Chonju (Korea, Republic of)

    2006-02-15

    A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mGi) of an I-131 solution. The anterior image of head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

  15. Visual Imagery and False Memory for Pictures: A Functional Magnetic Resonance Imaging Study in Healthy Participants.

    Science.gov (United States)

    Stephan-Otto, Christian; Siddi, Sara; Senior, Carl; Muñoz-Samons, Daniel; Ochoa, Susana; Sánchez-Laforga, Ana María; Brébion, Gildas

    2017-01-01

    Visual mental imagery might be critical in the ability to discriminate imagined from perceived pictures. Our aim was to investigate the neural bases of this specific type of reality-monitoring process in individuals with high visual imagery abilities. A reality-monitoring task was administered to twenty-six healthy participants using functional magnetic resonance imaging. During the encoding phase, 45 words designating common items, and 45 pictures of other common items, were presented in random order. During the recall phase, participants were required to remember whether a picture of the item had been presented, or only a word. Two subgroups of participants with a propensity for high vs. low visual imagery were contrasted. Activation of the amygdala, left inferior occipital gyrus, insula, and precuneus were observed when high visual imagers encoded words later remembered as pictures. At the recall phase, these same participants activated the middle frontal gyrus and inferior and superior parietal lobes when erroneously remembering pictures. The formation of visual mental images might activate visual brain areas as well as structures involved in emotional processing. High visual imagers demonstrate increased activation of a fronto-parietal source-monitoring network that enables distinction between imagined and perceived pictures.

  16. Differences in the origins of kinetochore-positive and kinetochore-negative micronuclei: A live cell imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Erkang, E-mail: erkangj@ustc.edu.cn

    2016-05-15

    Highlights: • Most Kinetochore-negative micronuclei were derived from kinetochore-negative displaced chromosomes, kinetochore-negative lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Most Kinetochore-positive micronuclei were derived from kinetochore-positive displaced chromosomes, kinetochore-positive lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Kinetochore-positive lagging chromosomes developed into kinetochore-positive micronuclei at the higher frequency than kinetochore-positive displaced chromosomes, kinetochore-negative lagging chromosomes developed into kinetochore-negative micronuclei at the higher rate than kinetochore-negative displaced chromosomes and broken chromosome bridges produced K−MNi and/or K+MNi. - Abstract: Micronuclei (MNi) are extensively used to evaluate genotoxicity and chromosomal instability. Classification of kinetochore-negative (K−MNi) and kinetochore-positive micronuclei (K+MNi) improves the specificity and sensitivity of the micronucleus (MN) test; however, the fundamental differences in the origins of K−MNi and K+MNi have not been addressed due to the limitations of traditional methods. In the current study, HeLa CENP B-GFP H2B-mCherry cells were constructed in which histone 2B (H2B) and centromere protein B (CENP B) were expressed as fusion proteins to monomeric Cherry (mCherry) and EGFP, respectively. MNi were identified using H2B-mCherry; K+MN contained CENP B-GFP, while K−MN did not. Long-term live cell imaging was conducted to examine MN formation in the dual-color fluorescent HeLa cells. The results suggested that K−MNi were derived from kinetochore-negative displaced chromosomes (K−DCs), kinetochore-negative lagging chromosomes (K−LCs) and fragments of broken chromosome bridges (CBs) during late mitotic stages. The results also indicated that K+MNi are derived from kinetochore-positive displaced chromosomes (K

  17. Differences in the origins of kinetochore-positive and kinetochore-negative micronuclei: A live cell imaging study

    International Nuclear Information System (INIS)

    Jiang, Erkang

    2016-01-01

    Highlights: • Most Kinetochore-negative micronuclei were derived from kinetochore-negative displaced chromosomes, kinetochore-negative lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Most Kinetochore-positive micronuclei were derived from kinetochore-positive displaced chromosomes, kinetochore-positive lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Kinetochore-positive lagging chromosomes developed into kinetochore-positive micronuclei at the higher frequency than kinetochore-positive displaced chromosomes, kinetochore-negative lagging chromosomes developed into kinetochore-negative micronuclei at the higher rate than kinetochore-negative displaced chromosomes and broken chromosome bridges produced K−MNi and/or K+MNi. - Abstract: Micronuclei (MNi) are extensively used to evaluate genotoxicity and chromosomal instability. Classification of kinetochore-negative (K−MNi) and kinetochore-positive micronuclei (K+MNi) improves the specificity and sensitivity of the micronucleus (MN) test; however, the fundamental differences in the origins of K−MNi and K+MNi have not been addressed due to the limitations of traditional methods. In the current study, HeLa CENP B-GFP H2B-mCherry cells were constructed in which histone 2B (H2B) and centromere protein B (CENP B) were expressed as fusion proteins to monomeric Cherry (mCherry) and EGFP, respectively. MNi were identified using H2B-mCherry; K+MN contained CENP B-GFP, while K−MN did not. Long-term live cell imaging was conducted to examine MN formation in the dual-color fluorescent HeLa cells. The results suggested that K−MNi were derived from kinetochore-negative displaced chromosomes (K−DCs), kinetochore-negative lagging chromosomes (K−LCs) and fragments of broken chromosome bridges (CBs) during late mitotic stages. The results also indicated that K+MNi are derived from kinetochore-positive displaced chromosomes (K

  18. Evaluation of orthognathic surgery on articular disc position and temporomandibular joint symptoms in skeletal class II patients: A Magnetic Resonance Imaging study

    Science.gov (United States)

    Firoozei, Gholamreza; Shahnaseri, Shirin; Momeni, Hasan

    2017-01-01

    Background The purpose of orthognathic surgery is to correct facial deformity and dental malocclusion and to obtain normal orofacial function. However, there are controversies of whether orthognathic surgery might have any negative influence on temporomandibular (TM) joint. The purpose of this study was to evaluate the influence of orthognathic surgery on articular disc position and temporomandibular joint symptoms of skeletal CI II patients by means of magnetic resonance imaging. Material and Methods For this purpose, fifteen patients with skeletal CI II malocclusion, aged 19-32 years (mean 23 years), 10 women and 5 men, from the Isfahan Department of Oral and Maxillofacial Surgery were studied. All received LeFort I and bilateral sagittal split osteotomy (BSSO) osteotomies and all patients received pre- and post-surgical orthodontic treatment. Magnetic resonance imaging was performed 1 day preoperatively and 3 month postoperatively. Descriptive statistics and Wilcoxon and Mc-Nemar tests were used for statistical analysis. Psurgery (mean=5.74±1.21). After surgery disc position range was 4.36 to 7.40 (mean=5.65±1.06). Statistical analysis proved that although TM disc tended to move anteriorly after BSSO surgery, this difference was not statistically significant (p valueorthognathic surgery does not alter the disc and condyle relationship. Therefore, it has minimal effects on intact and functional TM joint. Key words:Orthognathic surgery, skeletal class 2, magnetic resonance imaging, temporomandibular disc. PMID:28936287

  19. Triple correlation in temporomandibular joint dysfunction: MR imaging with arthrography, arthroscopy, and open surgery

    International Nuclear Information System (INIS)

    Rao, V.M.; Farole, A.; Karasick, D.

    1988-01-01

    Triple correlation of MR imaging with arthrography, arthroscopy, and open surgery was performed in 24 patients (34 temporomandibular joints) with ages ranging from 17 to 66 years. MR imaging showed disk position and morphologic features accurately in 30 joints (88%). It was false negative in one joint and false positive in three joints (9%). Degenerative changes were accurately detected with MR imaging, arthrography, and arthroscopy. Adhesions were diagnosed with arthrography in eight joints, arthroscopy in 14, and MR imaging in none. Disk perforations seen at open surgery were not detected with MR imaging. In conclusion, there is an overlap of information presented by various modalities. MR imaging is better than arthrography detecting disk morphologic features and displacement. Arthrography may add information by showing meniscal dynamics. Arthroscopy entails direct observation of superior joint space only and can detect adhesions and perforations better, but it may alter disk position and dynamics. In the more difficult cases, triple correlation may be needed, as modalities can be complementary

  20. The effect of image position on the Independent Components of natural binocular images.

    Science.gov (United States)

    Hunter, David W; Hibbard, Paul B

    2018-01-11

    Human visual performance degrades substantially as the angular distance from the fovea increases. This decrease in performance is found for both binocular and monocular vision. Although analysis of the statistics of natural images has provided significant insights into human visual processing, little research has focused on the statistical content of binocular images at eccentric angles. We applied Independent Component Analysis to rectangular image patches cut from locations within binocular images corresponding to different degrees of eccentricity. The distribution of components learned from the varying locations was examined to determine how these distributions varied across eccentricity. We found a general trend towards a broader spread of horizontal and vertical position disparity tunings in eccentric regions compared to the fovea, with the horizontal spread more pronounced than the vertical spread. Eccentric locations above the centroid show a strong bias towards far-tuned components, eccentric locations below the centroid show a strong bias towards near-tuned components. These distributions exhibit substantial similarities with physiological measurements in V1, however in common with previous research we also observe important differences, in particular distributions of binocular phase disparity which do not match physiology.

  1. False belief reasoning in the brain: An ERP study

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Understanding others mind and interpersonal interaction are the cognitive basis of successful social interactions. People’s mental states and behaviors rely on their holding beliefs for self and others. To investigate the neural substrates of false belief reasoning, the 32 channels event-related potentials (ERP) of 14 normal adults were measured while they understood false-belief and true belief used de-ceptive appearance task. After onset of the false-belief or true-belief questions, N100, P200 and late negative component (LNC) were elicited at centro-frontal sites. Compared with true belief, false belief reasoning elicited significant declined LNC in the time window from 400 to 800 ms. The source analysis of difference wave (False minus True) showed a dipole located in the middle cingulated cortex. These findings show that false belief reasoning probably included inhibitive process.

  2. False belief reasoning in the brain: An ERP study

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Understanding others mind and interpersonal interaction are the cognitive basis of successful social interactions. People's mental states and behaviors rely on their holding beliefs for self and others. To investigate the neural substrates of false belief reasoning, the 32 channels event-related potentials (ERP) of 14 normal adults were measured while they understood false-belief and true belief used deceptive appearance task. After onset of the false-belief or true-belief questions, N100, P200 and late negative component (LNC) were elicited at centro-frontal sites. Compared with true belief, false belief reasoning elicited significant declined LNC in the time window from 400 to 800 ms. The source analysis of difference wave (False minus True) showed a dipole located in the middle cingulated cortex. These findings show that false belief reasoning probably included inhibitive process.

  3. A quality control study of the accuracy of patient positioning in irradiation of pelvic fields

    International Nuclear Information System (INIS)

    Creutzberg, Carien L.; Althof, Vincent G.M.; Hoog, Marjan de; Visser, Andries G.; Huizenga, Henk; Wijnmaalen, Arendjan; Levendag, Peter C.

    1996-01-01

    Purpose: Determining and improving the accuracy of patient positioning in pelvic fields. Methods and Materials: Small pelvic fields were studied in 16 patients treated for urological cancers using a three-field isocentric technique. Large pelvic fields were studied in 17 gynecological cancer patients treated with anterior and posterior (AP-PA) parallel opposed fields. Quantitative analysis of 645 megavolt images and comparison to 82 simulation images were carried out. Results: Small pelvic fields: for the position of the patient in the field, standard deviations of the difference between simulation (SIM) and treatment (MV) images were 3.4 mm in the lateral direction, 5.3 mm in the cranio-caudal direction, and 4.8 mm in the ventro-dorsal direction. Alterations in the positioning technique were made and tested. Large pelvic fields: differences between simulation and treatment images for the position of the patient in the field were 4 mm [1 standard deviation (SD)] in the lateral direction and 6.5 mm in the cranio-caudal direction. A systematic shift of the treatment field in the cranial direction had occurred in the majority of patients. A positioning technique using laser lines and marking of the caudal field border was shown to be more accurate. Conclusion: Studies of positioning accuracy in routine irradiation techniques are needed to obtain data for definition of the margins for each treatment site at each institution. Random variations should be kept at a minimum by monitoring and improving positioning techniques. Treatment verification by megavolt imaging or film should be used to detect and correct systematic variations early in the treatment series

  4. Improving face image extraction by using deep learning technique

    Science.gov (United States)

    Xue, Zhiyun; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.

    2016-03-01

    The National Library of Medicine (NLM) has made a collection of over a 1.2 million research articles containing 3.2 million figure images searchable using the Open-iSM multimodal (text+image) search engine. Many images are visible light photographs, some of which are images containing faces ("face images"). Some of these face images are acquired in unconstrained settings, while others are studio photos. To extract the face regions in the images, we first applied one of the most widely-used face detectors, a pre-trained Viola-Jones detector implemented in Matlab and OpenCV. The Viola-Jones detector was trained for unconstrained face image detection, but the results for the NLM database included many false positives, which resulted in a very low precision. To improve this performance, we applied a deep learning technique, which reduced the number of false positives and as a result, the detection precision was improved significantly. (For example, the classification accuracy for identifying whether the face regions output by this Viola- Jones detector are true positives or not in a test set is about 96%.) By combining these two techniques (Viola-Jones and deep learning) we were able to increase the system precision considerably, while avoiding the need to manually construct a large training set by manual delineation of the face regions.

  5. Mapping of the image quality in myocardial scintigraphy: A national study; Kartlaeggning av bildkvalitet vid myokardscintigrafi: en nationell studie

    Energy Technology Data Exchange (ETDEWEB)

    Ohlson, Maria; Gustafsson, Agnetha (Radiofysikavd., Universitetssjukhuset, Linkoeping (SE)); Gretarsdottir, Jakobina (Diagnostik, Sahlgrenska Universitetssjukhuset, Goeteborg (SE)); Olsson, Eva (Fysiologiska kliniken, Universitetssjukhuset, Linkoeping (SE)); Johansson, Lena (Klinisk Fysiologi, Sahlgrenska Universitetssjukhuset, Goeteborg (SE))

    2008-04-15

    The aim of this study was to make a survey over the physical parameters and how they affect the image quality and the final diagnosis for myocardial perfusion SPECT in Sweden. Another aim was to evaluate the need for standardized acquisition and processing protocols for myocardial perfusion SPECT. All thirty nuclear medicine departments in Sweden that perform myocardial perfusion SPECT participated in the study. A thorax heart phantom was used to simulate two patients. All studies were acquired and processed with the parameters used clinically in each hospital respectively. A quantitative and a qualitative evaluation were performed. At each hospital, the local nuclear medicine physician interpreted the images as if they were true patient images. There are great differences in the acquiring and processing parameters used in myocardial perfusion SPECT studies in Sweden. The image quality varies greatly for the different hospital but was approved for the majority of the hospitals. Images from two hospitals were considered to be too poor to be diagnosed. The interpretations of the local nuclear medicine physicians differ but the majority has reported an adequate diagnosis. One third of the hospitals have reported false positive defects. All steps in the chain from the acquisition to the evaluation of the medicine physician must be performed with high quality. The determinative factors are the noise reduction filter, the orientation of the slices in the heart and the judgement of the local medicine physician. The acquiring and processing parameters proposed by EANM should be used. The hospitals are also recommended to investigate in the time and resources available, in order to educate all staff involved in the evaluation of myocardial studies

  6. Visual Imagery and False Memory for Pictures: A Functional Magnetic Resonance Imaging Study in Healthy Participants.

    Directory of Open Access Journals (Sweden)

    Christian Stephan-Otto

    Full Text Available Visual mental imagery might be critical in the ability to discriminate imagined from perceived pictures. Our aim was to investigate the neural bases of this specific type of reality-monitoring process in individuals with high visual imagery abilities.A reality-monitoring task was administered to twenty-six healthy participants using functional magnetic resonance imaging. During the encoding phase, 45 words designating common items, and 45 pictures of other common items, were presented in random order. During the recall phase, participants were required to remember whether a picture of the item had been presented, or only a word. Two subgroups of participants with a propensity for high vs. low visual imagery were contrasted.Activation of the amygdala, left inferior occipital gyrus, insula, and precuneus were observed when high visual imagers encoded words later remembered as pictures. At the recall phase, these same participants activated the middle frontal gyrus and inferior and superior parietal lobes when erroneously remembering pictures.The formation of visual mental images might activate visual brain areas as well as structures involved in emotional processing. High visual imagers demonstrate increased activation of a fronto-parietal source-monitoring network that enables distinction between imagined and perceived pictures.

  7. SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

    Energy Technology Data Exchange (ETDEWEB)

    Neal, B; Ahmed, M; Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

  8. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    International Nuclear Information System (INIS)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung; Lee, Jin Yong

    2016-01-01

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length

  9. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung [Dept. of Radiology, Chungbuk National University Hospital, Cheongju (Korea, Republic of); Lee, Jin Yong [Public Health Medical Service, Seoul National University Boramae Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length.

  10. Verification of multileaf collimator leaf positions using an electronic portal imaging device

    International Nuclear Information System (INIS)

    Samant, Sanjiv S.; Zheng Wei; Parra, Nestor Andres; Chandler, Jason; Gopal, Arun; Wu Jian; Jain Jinesh; Zhu Yunping; Sontag, Marc

    2002-01-01

    An automated method is presented for determining individual leaf positions of the Siemens dual focus multileaf collimator (MLC) using the Siemens BEAMVIEW(PLUS) electronic portal imaging device (EPID). Leaf positions are computed with an error of 0.6 mm at one standard deviation (σ) using separate computations of pixel dimensions, image distortion, and radiation center. The pixel dimensions are calculated by superimposing the film image of a graticule with the corresponding EPID image. A spatial correction is used to compensate for the optical distortions of the EPID, reducing the mean distortion from 3.5 pixels (uncorrected) per localized x-ray marker to 2 pixels (1 mm) for a rigid rotation and 1 pixel for a third degree polynomial warp. A correction for a nonuniform dosimetric response across the field of view of the EPID images is not necessary due to the sharp intensity gradients across leaf edges. The radiation center, calculated from the average of the geometric centers of a square field at 0 deg. and 180 deg. collimator angles, is independent of graticule placement error. Its measured location on the EPID image was stable to within 1 pixel based on 3 weeks of repeated extensions/retractions of the EPID. The MLC leaf positions determined from the EPID images agreed to within a pixel of the corresponding values measured using film and ionization chamber. Several edge detection algorithms were tested: contour, Sobel, Roberts, Prewitt, Laplace, morphological, and Canny. These agreed with each other to within ≤1.2 pixels for the in-air EPID images. Using a test pattern, individual MLC leaves were found to be typically within 1 mm of the corresponding record-and-verify values, with a maximum difference of 1.8 mm, and standard deviations of <0.3 mm in the daily reproducibility. This method presents a fast, automatic, and accurate alternative to using film or a light field for the verification and calibration of the MLC

  11. Diagnosis and staging of breast cancer by SPECT images fused with CT images

    International Nuclear Information System (INIS)

    Li Yanjing; Zhu Qiaomei

    2007-01-01

    Objective: To evaluate the TNM staging value of 99mTc-MIBI scintimammotraphy with SPECT-CT images fusing for the diagnosis of breast cancer. Methods: 10 patients with breast cancer underwent scintimammography with 99mTc-MIBI, and SPECT images were fused with CT images. Images were compared with final diagnosis confirmed by histopathology. Results: Of the 19 breast cancer patients, one case of invasive ductal carcinoma showed false-negative. Among 18 cases of positive lesions, axillary metastases were involved in 10, supraclavicular nodes were also defined in 3, para-sternum nodes were involved in 2, 2 were missed and 1 cases without metastatic node. The axillary lymph nodes were divided into three levels with respect to their position relative to the pectoralis minor muscle by fused images. Conclusion: 99mTc-MIBI scintimammotraphy combined with SPECT-CT images fusing is of some clinical value in TNM staging of breast cancer. (authors)

  12. Unique thermal record in False Bay

    CSIR Research Space (South Africa)

    Grundlingh, ML

    1993-10-01

    Full Text Available Over the past decade False Bay has assumed a prime position in terms of research in to large South African bays. This is manifested by investigations that cover flow conditions modelling, thermal structure, management, biology and nutrients, geology...

  13. Ship Detection in Optical Remote Sensing Images Based on Wavelet Transform and Multi-Level False Alarm Identification

    Directory of Open Access Journals (Sweden)

    Fang Xu

    2017-09-01

    Full Text Available Ship detection by Unmanned Airborne Vehicles (UAVs and satellites plays an important role in a spectrum of related military and civil applications. To improve the detection efficiency, accuracy, and speed, a novel ship detection method from coarse to fine is presented. Ship targets are viewed as uncommon regions in the sea background caused by the differences in colors, textures, shapes, or other factors. Inspired by this fact, a global saliency model is constructed based on high-frequency coefficients of the multi-scale and multi-direction wavelet decomposition, which can characterize different feature information from edge to texture of the input image. To further reduce the false alarms, a new and effective multi-level discrimination method is designed based on the improved entropy and pixel distribution, which is robust against the interferences introduced by islands, coastlines, clouds, and shadows. The experimental results on optical remote sensing images validate that the presented saliency model outperforms the comparative models in terms of the area under the receiver operating characteristic curves core and the accuracy in the images with different sizes. After the target identification, the locations and the number of the ships in various sizes and colors can be detected accurately and fast with high robustness.

  14. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  15. The diagnostic value of diffusion-weighted magnetic resonance imaging in soft tissue abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Ozkan; Koparan, Halil Ibrahim [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Avcu, Serhat, E-mail: serhatavcu@hotmail.com [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Kalender, Ali Murat [Yuezuencue Yil University, Department of Orthopaedics, General Surgery, Van (Turkey); Kisli, Erol [Yuezuencue Yil University, Department of General Surgery, Van (Turkey)

    2011-03-15

    Purpose: To study the diagnostic value of diffusion-weighted imaging (DWI) in soft tissue abscesses. Materials and methods: Fifty patients were included in this study who were thought to have soft tissue abscess or cystic lesion as a result of clinical and radiological examinations. Localisations of the lesions were: 1 periorbital, 3 breast, 14 intraabdominal, and 32 intramuscular lesions. After other radiological examinations, DWI was performed. The signal intensity values of the lesions were evaluated qualitatively according to the hyperintensity on b-1000 DWI, using 1.5 T MR system. All of the lesions were aspirated after DWI, and detection of pus in the aspiration material was accepted as gold standard for the diagnosis of abscess. Results: In 38 of the 50 patients, hyperintensity was obtained on diffusion-weighted images. False-positive results were maintained in 2 of these patients, and true-positive results were maintained in 36 of them. In 11 of the 50 patients, hypointensity was visualised on diffusion-weighted images. False-negative results were maintained in 3 of these patients, and true-negative results were maintained in 8 of them. An abscess which was seen on post-contrast conventional MRI could not be seen on DWI, and this was regarded as false-negative. Conclusion: The sensitivity and specificity of diffusion-weighted images for detecting soft tissue abscesses were found to be 92% and 80%, respectively. DWI has a high diagnostic value in soft tissue abscesses, and is an important imaging modality that may be used for the differentiation of cysts and abscesses.

  16. The diagnostic value of diffusion-weighted magnetic resonance imaging in soft tissue abscesses

    International Nuclear Information System (INIS)

    Unal, Ozkan; Koparan, Halil Ibrahim; Avcu, Serhat; Kalender, Ali Murat; Kisli, Erol

    2011-01-01

    Purpose: To study the diagnostic value of diffusion-weighted imaging (DWI) in soft tissue abscesses. Materials and methods: Fifty patients were included in this study who were thought to have soft tissue abscess or cystic lesion as a result of clinical and radiological examinations. Localisations of the lesions were: 1 periorbital, 3 breast, 14 intraabdominal, and 32 intramuscular lesions. After other radiological examinations, DWI was performed. The signal intensity values of the lesions were evaluated qualitatively according to the hyperintensity on b-1000 DWI, using 1.5 T MR system. All of the lesions were aspirated after DWI, and detection of pus in the aspiration material was accepted as gold standard for the diagnosis of abscess. Results: In 38 of the 50 patients, hyperintensity was obtained on diffusion-weighted images. False-positive results were maintained in 2 of these patients, and true-positive results were maintained in 36 of them. In 11 of the 50 patients, hypointensity was visualised on diffusion-weighted images. False-negative results were maintained in 3 of these patients, and true-negative results were maintained in 8 of them. An abscess which was seen on post-contrast conventional MRI could not be seen on DWI, and this was regarded as false-negative. Conclusion: The sensitivity and specificity of diffusion-weighted images for detecting soft tissue abscesses were found to be 92% and 80%, respectively. DWI has a high diagnostic value in soft tissue abscesses, and is an important imaging modality that may be used for the differentiation of cysts and abscesses.

  17. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    International Nuclear Information System (INIS)

    Ogunmolu, O; Gans, N; Jiang, S; Gu, X

    2015-01-01

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control

  18. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    Energy Technology Data Exchange (ETDEWEB)

    Ogunmolu, O; Gans, N [The University of Texas at Dallas, Richardson, TX (United States); Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control

  19. False-positive breast screening due to fat necrosis following mammography

    International Nuclear Information System (INIS)

    Cawson, Jennifer N.; Malara, Frank A.

    2004-01-01

    Traumatic fat necrosis can result in a spectrum of imaging appearances that range from characteristically benign to those indistinguishable from malignancy. In such cases, biopsy might be required for diagnosis. The present case demonstrates a suspicious mammographic mass lesion appearing following a haematoma caused by a previous screening mammogram Copyright (2004) Blackwell Publishing Asia Pty Ltd

  20. Rates of Amyloid Imaging Positivity in Patients With Primary Progressive Aphasia

    Science.gov (United States)

    Santos-Santos, Miguel A.; Rabinovici, Gil D.; Iaccarino, Leonardo; Ayakta, Nagehan; Tammewar, Gautam; Lobach, Iryna; Henry, Maya L.; Hubbard, Isabel; Mandelli, Maria Luisa; Spinelli, Edoardo; Miller, Zachary A.; Pressman, Peter S.; O’Neil, James P.; Ghosh, Pia; Lazaris, Andreas; Meyer, Marita; Watson, Christa; Yoon, Soo Jin; Rosen, Howard J.; Grinberg, Lea; Seeley, William W.; Miller, Bruce L.; Jagust, William J.; Gorno-Tempini, Maria Luisa

    2018-01-01

    IMPORTANCE The ability to predict the pathology underlying different neurodegenerative syndromes is of critical importance owing to the advent of molecule-specific therapies. OBJECTIVE To determine the rates of positron emission tomography (PET) amyloid positivity in the main clinical variants of primary progressive aphasia (PPA). DESIGN, SETTING, AND PARTICIPANTS This prospective clinical-pathologic case series was conducted at a tertiary research clinic specialized in cognitive disorders. Patients were evaluated as part of a prospective, longitudinal research study between January 2002 and December 2015. Inclusion criteria included clinical diagnosis of PPA; availability of complete speech, language, and cognitive testing; magnetic resonance imaging performed within 6 months of the cognitive evaluation; and PET carbon 11–labeled Pittsburgh Compound-B or florbetapir F 18 brain scan results. Of 109 patients referred for evaluation of language symptoms who underwent amyloid brain imaging, 3 were excluded because of incomplete language evaluations, 5 for absence of significant aphasia, and 12 for presenting with significant initial symptoms outside of the language domain, leaving a cohort of 89 patients with PPA. MAIN OUTCOMES AND MEASURES Clinical, cognitive, neuroimaging, and pathology results. RESULTS Twenty-eight cases were classified as imaging-supported semantic variant PPA (11 women [39.3%]; mean [SD] age, 64 [7] years), 31 nonfluent/agrammatic variant PPA (22 women [71.0%]; mean [SD] age, 68 [7] years), 26 logopenic variant PPA (17 women [65.4%]; mean [SD] age, 63 [8] years), and 4 mixed PPA cases. Twenty-four of 28 patients with semantic variant PPA (86%) and 28 of 31 patients with nonfluent/agrammatic variant PPA (90%) had negative amyloid PET scan results, while 25 of 26 patients with logopenic variant PPA (96%) and 3 of 4 mixed PPA cases (75%) had positive scan results. The amyloid positive semantic variant PPA and nonfluent/agrammatic variant PPA cases

  1. Navicular bone position determined by positional MRI: a reproducibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Philip; Nybing, Janus D. [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Johannsen, Finn E.; Stallknecht, Sandra E. [Copenhagen University Hospital Bispebjerg, Institute of Sports Medicine Copenhagen, Copenhagen, NV (Denmark); Hangaard, Stine; Hansen, Bjarke B. [Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark); Boesen, Mikael [Copenhagen University Hospital Frederiksberg and Bispebjerg, Department of Radiology, Frederiksberg (Denmark); Copenhagen University Hospital Frederiksberg, Parker Institute, Department of Rheumatology, Frederiksberg (Denmark)

    2016-02-15

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  2. Navicular bone position determined by positional MRI: a reproducibility study

    International Nuclear Information System (INIS)

    Hansen, Philip; Nybing, Janus D.; Johannsen, Finn E.; Stallknecht, Sandra E.; Hangaard, Stine; Hansen, Bjarke B.; Boesen, Mikael

    2016-01-01

    To examine intraobserver, interobserver and between-day reproducibility of positional MRI for evaluation of navicular bone height (NVH) and medial navicular position (MNP). Positional MRI (pMRI) of the foot was performed on ten healthy participants (0.25 T G-scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). Intraobserver and interobserver reliability was ''substantial'' in both supine and standing position (ICC 0.86-0.98) and showed good agreement (LOA% 4.9-14.7 %). Between-day reliability of navicular height and medial navicular position in standing position remained substantial (ICC 0.85-0.92) with adequate agreement (LOA% 8.3-19.8 %). In supine position between-day reliability was ''moderate'' for NVH (ICC 0.72) and ''slight'' for MNP (ICC 0.39). Agreement remained adequate between-days for MNP in supine position (LOA% 17.7 %), but it was less than adequate for NVH in supine position (LOA% 24.2 %). Navicular height and medial navicular position can be measured by pMRI in a very reproducible manner within and between observers. Increased measurement variation is observed between-days in supine position, which may be due to small positional differences or other unknown biomechanical factors. (orig.)

  3. Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahn, Hyoun Suk; Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ disc were assessed. Lateral or medial disc displacement was also evaluated on cornal images. Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 disc. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality

  4. SU-D-202-02: Quantitative Imaging: Correlation Between Image Feature Analysis and the Accuracy of Manually Drawn Contours On PET Images

    Energy Technology Data Exchange (ETDEWEB)

    Lamichhane, N; Johnson, P; Chinea, F; Patel, V; Yang, F [University of Miami, Miami, FL (United States)

    2016-06-15

    Purpose: To evaluate the correlation between image features and the accuracy of manually drawn target contours on synthetic PET images Methods: A digital PET phantom was used in combination with Monte Carlo simulation to create a set of 26 simulated PET images featuring a variety of tumor shapes and activity heterogeneity. These tumor volumes were used as a gold standard in comparisons with manual contours delineated by 10 radiation oncologist on the simulated PET images. Metrics used to evaluate segmentation accuracy included the dice coefficient, false positive dice, false negative dice, symmetric mean absolute surface distance, and absolute volumetric difference. Image features extracted from the simulated tumors consisted of volume, shape complexity, mean curvature, and intensity contrast along with five texture features derived from the gray-level neighborhood difference matrices including contrast, coarseness, busyness, strength, and complexity. Correlation between these features and contouring accuracy were examined. Results: Contour accuracy was reasonably well correlated with a variety of image features. Dice coefficient ranged from 0.7 to 0.90 and was correlated closely with contrast (r=0.43, p=0.02) and complexity (r=0.5, p<0.001). False negative dice ranged from 0.10 to 0.50 and was correlated closely with contrast (r=0.68, p<0.001) and complexity (r=0.66, p<0.001). Absolute volumetric difference ranged from 0.0002 to 0.67 and was correlated closely with coarseness (r=0.46, p=0.02) and complexity (r=0.49, p=0.008). Symmetric mean absolute difference ranged from 0.02 to 1 and was correlated closely with mean curvature (r=0.57, p=0.02) and contrast (r=0.6, p=0.001). Conclusion: The long term goal of this study is to assess whether contouring variability can be reduced by providing feedback to the practitioner based on image feature analysis. The results are encouraging and will be used to develop a statistical model which will enable a prediction of

  5. Veridical and false recall in adults who stutter.

    Science.gov (United States)

    Byrd, Courtney T; Sheng, Li; Ratner, Nan Bernstein; Gkalitsiou, Zoi

    2015-02-01

    This study used a false memory paradigm to explore the veridical and false recall of adults who stutter. Twelve adults who stutter and 12 age-matched typically fluent peers listened to and then verbally recalled lists of words that consisted of either semantic or phonological associates or an equal number of semantic and phonological associates (i.e., hybrid condition) of a single, unpresented critical "lure" word. Three parameters of recall performance were measured across these 3 conditions: (a) number of accurately recalled words, (b) order of recall (primacy vs. recency effect), and (c) number of critical lures produced (i.e., false memories). Significant group differences were noted in recall accuracy specific to list type and also list position as well as relative to critical lure productions. Results suggest that certain basic memory processes (i.e., recency effect) and the processing of gist semantic information are largely intact in adults who stutter, but recall of verbatim phonological information and subvocal rehearsal may be deficient.

  6. Does Capitalism and the Culture Industry Create False Needs? A study of Marcuse, Adorno, and Horkheimer

    Directory of Open Access Journals (Sweden)

    Erbi Ago

    2015-07-01

    Full Text Available The world as we know it nowadays has evolved into an entity characterized by different political and economic systems. Each of these systems affects human mentality in a certain way. When focusing on capitalism and its culture industry, one cannot help but notice the different needs that are created as a result of different components of this system. To achieve an understanding of the needs, or rather, false needs created by the culture industry, a study of the latter would be provided at first. Furthermore, this paper aims at understanding whether it is only capitalism that creates a culture of false and unnecessary needs, in order to create a studying basis for future analysis where other systems could be analyzed and compared to the it. While implementing these societal analyses, it can then be possible to implement positive aspects of other systems, at least theoretically, into the capitalist system, providing therefore an economic system without false needs. The framework of this paper was characterized by the analysis of the three main minds that affected the Frankfurt School approach. Marx, Weber, and Lukacs’ theories were analyzed and their effect to the critical theorists was compared with the main works of Adorno, Marcuse and Horkheimer. Marx’s theory of commodity fetishism; Weber’s instrumental action and reasoning; and Lukacs’ reification of consciousness were all concepts that affected the latter thinkers in one way or another, allowing them to create a pivotal change in the academic and scholarly thinking on capitalism. In essence, this paper will describe, list, and analyze the aspects of capitalism that create our false needs.

  7. Is screening with digital imaging using one retinal view adequate?

    Science.gov (United States)

    Herbert, H M; Jordan, K; Flanagan, D W

    2003-05-01

    To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.

  8. Filing false vice reports: Distinguishing true from false allegations of rape

    NARCIS (Netherlands)

    de Zutter, A.; Horselenberg, R.; van Koppen, P.J.

    2017-01-01

    False allegations constitute a problem since they may cause harm. To study the difference between true and false allegations we used a quasi-experimental approach. In the control condition likely true allegations were retrieved from criminal files. The victims, all female, were between the ages of

  9. Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L. [Department of Medical Physics, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada and Nova Scotia Cancer Centre, QEII Health Science Centre, Halifax, Nova Scotia B3H 2Y9 (Canada)

    2016-05-15

    Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three

  10. An online x-ray based position validation system for prostate hypofractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, Sankar, E-mail: Sankar.Arumugam@sswahs.nsw.gov.au; Xing, Aitang [Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales 2170 (Australia); Sidhom, Mark [Department of Radiation Oncology, Liverpool and Macarthur Cancer Therapy Centres, New South Wales 2170 (Australia); Holloway, Lois [Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales 2170 (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2522 (Australia); South Western Clinical School, University of New South Wales, Sydney, New South Wales 2052 (Australia); Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2016-02-15

    Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and

  11. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  12. Automatic Detection of Vehicles Using Intensity Laser and Anaglyph Image

    Directory of Open Access Journals (Sweden)

    Hideo Araki

    2006-12-01

    Full Text Available In this work is presented a methodology to automatic car detection motion presents in digital aerial image on urban area using intensity, anaglyph and subtracting images. The anaglyph image is used to identify the motion cars on the expose take, because the cars provide red color due the not homology between objects. An implicit model was developed to provide a digital pixel value that has the specific propriety presented early, using the ratio between the RGB color of car object in the anaglyph image. The intensity image is used to decrease the false positive and to do the processing to work into roads and streets. The subtracting image is applied to decrease the false positives obtained due the markings road. The goal of this paper is automatically detect motion cars presents in digital aerial image in urban areas. The algorithm implemented applies normalization on the left and right images and later form the anaglyph with using the translation. The results show the applicability of proposed method and it potentiality on the automatic car detection and presented the performance of proposed methodology.

  13. A mega-analysis of memory reports from eight peer-reviewed false memory implantation studies

    OpenAIRE

    Scoboria, A.; Wade, Kimberley A.; Lindsay, D. S.; Azad, T.; Strange, D.; Ost, J.; Hyman, I. E.

    2016-01-01

    Understanding that suggestive practices can promote false beliefs and false memories forchildhood events is important in many settings (e.g., psychotherapeutic, medical, legal). The generalizability of findings from memory implantation studies has been questioned due to variability in estimates across studies. Such variability is partly due to false memories having been operationalized differently across studies and to differences in memory induction techniques. We explored ways of defining f...

  14. Breast cancer imaging using radiolabelled somatostatin analogues

    International Nuclear Information System (INIS)

    Dalm, Simone U.; Melis, Marleen; Emmering, Jasper; Kwekkeboom, Dik J.; Jong, Marion de

    2016-01-01

    Imaging and therapy using radiolabelled somatostatin analogues are methods successfully used in patients with somatostatin receptor (SSTR)-expressing neuroendocrine tumours. Since these techniques were first introduced, many improvements have been made. SSTR expression has also been reported on breast cancer (BC). Currently mammography, magnetic resonance imaging and ultrasound are the most frequent methods used for BC imaging. Since SSTR expression on BC was demonstrated, clinical studies examining the feasibility of visualizing primary BC using SSTR radioligands have been performed. However, to date SSTR-mediated nuclear imaging is not used clinically in BC patients. The aim of this review is to assess whether recent improvements made within nuclear medicine may enable SSTR-mediated imaging to play a role in BC management. For this we critically analysed results of past studies and discussed the potential of the improvements made within nuclear medicine on SSTR-mediated nuclear imaging of BC. Seven databases were searched for publications on BC imaging with SSTR radioligands. The papers found were analysed by 3 individual observers to identify whether the studies met the pre-set inclusion criteria defined as studies in which nuclear imaging using radiolabelled SST analogues was performed in patients with breast lesions. Twenty-four papers were selected for this review including studies on SSTR-mediated nuclear imaging in BC, neuroendocrine BC and other breast lesions. The analysed studies were heterogeneous with respect to the imaging method, imaging protocol, patient groups and the radiolabelled SST analogues used. Despite the fact that the analysed studies were heterogeneous, sensitivity for primary BC ranged from 36–100%. In a subset of the studies LN lesions were visualized, but sensitivity was lower compared to that for primary tumours. A part of the studies included benign lesions and specificity ranged from 22–100%. Furthermore, false negatives and

  15. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    International Nuclear Information System (INIS)

    Lerche, Ch.W.; Ros, A.; Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A.; Sanchez, F.; Benlloch, J.M.

    2009-01-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  16. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lerche, Ch.W. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain)], E-mail: lerche@ific.uv.es; Ros, A. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain); Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Sanchez, F.; Benlloch, J.M. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain)

    2009-06-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  17. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  18. Arousal—But Not Valence—Reduces False Memories at Retrieval

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico

    2016-01-01

    Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods–similar in arousal levels–correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval. PMID:26938737

  19. Arousal-But Not Valence-Reduces False Memories at Retrieval.

    Directory of Open Access Journals (Sweden)

    Chiara Mirandola

    Full Text Available Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1 whether valence and arousal equally affect false memory production, and (2 whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently, compared to individuals in neutral mood. This suggests that arousal (but not valence predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.

  20. Recursive belief manipulation and second-order false-beliefs

    DEFF Research Database (Denmark)

    Braüner, Torben; Blackburn, Patrick Rowan; Polyanskaya, Irina

    2016-01-01

    it indicate that a more fundamental *conceptual change* has taken place? In this paper we extend Braüner's hybrid-logical analysis of first-order false-belief tasks to the second-order case, and argue that our analysis supports a version of the conceptual change position.......The literature on first-order false-belief is extensive, but less is known about the second-order case. The ability to handle second-order false-beliefs correctly seems to mark a cognitively significant step, but what is its status? Is it an example of *complexity only* development, or does...