WorldWideScience

Sample records for iii robotic radical

  1. Salvage robotic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Samuel D Kaffenberger

    2014-01-01

    Full Text Available Failure of non-surgical primary treatment for localized prostate cancer is a common occurrence, with rates of disease recurrence ranging from 20% to 60%. In a large proportion of patients, disease recurrence is clinically localized and therefore potentially curable. Unfortunately, due to the complex and potentially morbid nature of salvage treatment, radical salvage surgery is uncommonly performed. In an attempt to decrease the morbidity of salvage therapy without sacrificing oncologic efficacy, a number of experienced centers have utilized robotic assistance to perform minimally invasive salvage radical prostatectomy. Herein, we critically evaluate the existing literature on salvage robotic radical prostatectomy with a focus on patient selection, perioperative complications and functional and early oncologic outcomes. These results are compared with contemporary and historical open salvage radical prostatectomy series and supplemented with insights we have gained from our experience with salvage robotic radical prostatectomy. The body of evidence by which conclusions regarding the efficacy and safety of robotic salvage radical prostatectomy can be drawn comprises fewer than 200 patients with limited follow-up. Preliminary results are promising and some outcomes have been favorable when compared with contemporary open salvage prostatectomy series. Advantages of the robotic platform in the performance of salvage radical prostatectomy include decreased blood loss, short length of stay and improved visualization. Greater experience is required to confirm the long-term oncologic efficacy and functional outcomes as well as the generalizability of results achieved at experienced centers.

  2. Robotic radical hysterectomy in the management of gynecologic malignancies.

    Science.gov (United States)

    Pareja, Rene; Ramirez, Pedro T

    2008-01-01

    Robotic surgery is being used with increasing frequency in gynecologic oncology. To date, 44 cases were reported in the literature of radical hysterectomy performed with robotic surgery. When comparing robotic surgery with laparoscopy or laparotomy in performing a radical hysterectomy, the literature shows that robotic surgery offers an advantage over the other 2 surgical approaches with regard to operative time, blood loss, and length of hospitalization. Future studies are needed to further elucidate the equivalence or superiority of robotic surgery to laparoscopy or laparotomy in performing a radical hysterectomy.

  3. Robot-assisted radical prostatectomy is a safe procedure

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebæk; Berg, Kasper Drimer; Hvarness, Helle

    2013-01-01

    We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients.......We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients....

  4. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    Science.gov (United States)

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Contemporary open and robotic radical prostatectomy practice patterns among urologists in the United States.

    Science.gov (United States)

    Lowrance, William T; Eastham, James A; Savage, Caroline; Maschino, A C; Laudone, Vincent P; Dechet, Christopher B; Stephenson, Robert A; Scardino, Peter T; Sandhu, Jaspreet S

    2012-06-01

    We describe current trends in robotic and open radical prostatectomy in the United States after examining case logs for American Board of Urology certification. American urologists submit case logs for initial board certification and recertification. We analyzed logs from 2004 to 2010 for trends and used logistic regression to assess the impact of urologist age on robotic radical prostatectomy use. A total of 4,709 urologists submitted case logs for certification between 2004 and 2010. Of these logs 3,374 included 1 or more radical prostatectomy cases. Of the urologists 2,413 (72%) reported performing open radical prostatectomy only while 961 (28%) reported 1 or more robotic radical prostatectomies and 308 (9%) reported robotic radical prostatectomy only. During this 7-year period we observed a large increase in the number of urologists who performed robotic radical prostatectomy and a smaller corresponding decrease in those who performed open radical prostatectomy. Only 8% of patients were treated with robotic radical prostatectomy by urologists who were certified in 2004 while 67% underwent that procedure in 2010. Median age of urologists who exclusively performed open radical prostatectomy was 43 years (IQR 38-51) vs 41 (IQR 35-46) for those who performed only robotic radical prostatectomy. While the rate was not as high as the greater than 85% industry estimate, 67% of radical prostatectomies were done robotically among urologists who underwent board certification or recertification in 2010. Total radical prostatectomy volume almost doubled during the study period. These data provide nonindustry based estimates of current radical prostatectomy practice patterns and further our understanding of the evolving surgical treatment of prostate cancer. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Robotic radical hysterectomy with pelvic lymphadenectomy: our early experience.

    Science.gov (United States)

    Vasilescu, C; Sgarbură, O; Tudor, St; Popa, M; Turcanu, A; Florescu, A; Herlea, V; Anghel, R

    2009-01-01

    Robotic surgery overcomes some limitations of laparoscopic surgery for prostate, rectal and uterine cancer. In this study we analyze the feasibility of robotic radical hysterectomy with pelvic lymphadenectomy in gynecological cancers in a developping program of robotic surgery. This prospective study started the 1st of March 2008. Since then, 250 cases of robotic surgery were performed out of which 29 cases addressed gynecological conditions. We selected all radical interventions summing up to 19 cases. Our final group consisted of 19 patients, a gedbetween 30 and 78 years old, with an average age of 53.22 years (+/- 10.03). Twelve patients were diagnosed with cervical cancer, the rest of them with endometrial cancer. Mean operative time was 180 +/- 23.45 min. Oral intake were started the next day after the operation and the patients were discharged 3.5 (+/- 1.2) days postoperatively. There were 3 urinary complications in patients with tumors adherent to the urinary bladder. We believe that robotic radical hysterectomy with pelvic lymphadenectomy in gynecological cancers is a rapid, feasible, and secure method that should be used whenever available. However further prospective studies and late follow-up results are needed in order to fully assess the value of this new technology.

  7. Robot-assisted radical prostatectomy in Brazil: preliminary results

    Directory of Open Access Journals (Sweden)

    Jose Roberto Colombo Junior

    2009-12-01

    Full Text Available Purpose: To report the initial experience on robot-assisted radical prostatectomy in Brazil. Methods: From March 2008 to March 2009, a hundred patients were treated with robot-assisted radical prostatectomy. Patient’s demographic data, as well as perioperative results of the procedures, are described in this study. Rresults: Patients’ mean age and mean PSA were 58 years and 7.58 ng/ml, respectively. All procedures were performed through transperitoneal approach, with a mean bleeding of 480 mL and surgical time of 298 minutes. A surgical margin affected by cancer was present in 16% of the cases. There were four complications: bleeding requiring transfusion (two cases, rectal perforation corrected on the spot and inadequate functioning of the robot. There was no conversion to another access or obit occurrences in this caseload. Cconclusions: Robot-assisted prostatectomy is a reality in Brazil and the results herein presented demonstrate that this procedure can be safely performed. Long-term follow-up is still necessary to assess the oncological and functional outcomes.

  8. Robotic radical perineal cystectomy and extended pelvic lymphadenectomy: initial investigation using a purpose-built single-port robotic system.

    Science.gov (United States)

    Maurice, Matthew J; Kaouk, Jihad H

    2017-12-01

    To assess the feasibility of radical perineal cystoprostatectomy using the latest generation purpose-built single-port robotic surgical system. In two male cadavers the da Vinci ® SP1098 Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) was used to perform radical perineal cystoprostatectomy and bilateral extended pelvic lymph node dissection (ePLND). New features in this model include enhanced high-definition three-dimensional optics, improved instrument manoeuvrability, and a real-time instrument tracking and guidance system. The surgery was accomplished through a 3-cm perineal incision via a novel robotic single-port system, which accommodates three double-jointed articulating robotic instruments, an articulating camera, and an accessory laparoscopic instrument. The primary outcomes were technical feasibility, intraoperative complications, and total robotic operative time. The cases were completed successfully without conversion. There were no accidental punctures or lacerations. The robotic operative times were 197 and 202 min. In this preclinical model, robotic radical perineal cystoprostatectomy and ePLND was feasible using the SP1098 robotic platform. Further investigation is needed to assess the feasibility of urinary diversion using this novel approach and new technology. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  9. Aufbau des humanoiden Roboters BART III

    Science.gov (United States)

    Resetov, Dimitri; Pietsch, Björn; Gerth, Wilfried

    Der vorliegende Beitrag präsentiert den humanoiden Roboter BART III, der am Institut für Regelungstechnik als eine robuste und erweiterbare Plattform für weiterführende Grundlagenforschung zur zweibeinigen Fortbewegung entwickelt wurde. Im Gegensatz zu den bisher am IRT genutzten Robotern BARt-UH und LISA besitzt der neue Roboter einen beweglichen Oberkörper mit einem Bauchgelenk und Armen. BART III besitzt insgesamt 19 aktive Freiheitsgrade, 12 davon im Unterkörper. Ein weiteres Merkmal des Roboters ist die im gesamten Körper verteilte Ansteuerelektronik, die neben der lokalen Motorregelung diverse sicherheitsrelevante Funktionen übernimmt.

  10. Initial consecutive 125 cases of robotic assisted laparoscopic radical prostatectomy performed in Ireland's first robotic radical prostatectomy centre.

    LENUS (Irish Health Repository)

    Bouchier-Hayes, D M

    2012-03-01

    We examined the patient characteristics, operative proceedings and the outcomes of the initial series of 125 cases of robot-assisted laparoscopic radical prostatectomy (RALRP) in an independent hospital in Ireland, performed by two surgeons using the da Vinci(®) surgical system.

  11. Outcome of Robotic Radical Prostatectomy in Men Over 74.

    Science.gov (United States)

    Ubrig, Burkhard; Boy, Anselm; Heiland, Markus; Roosen, Alexander

    2018-02-01

    We set out to evaluate outcomes in patients over 74 after robotic radical prostatectomy. Six hundred forty-seven patients over 74 (≥75) were analyzed for preoperative factors (body mass index [BMI], American Society of Anestesiologists classification [ASA], prostate-specific antigen [PSA], International prostate symptome score [IPSS], International index of erectile function [IIEF]), operative and perioperative characteristics (technique, erythrocyte conc., complications), and histopathological results. After 12 months, following items were assessed: PSA, frequency of urine loss, number of pads used (including safety), incontinence at night, and potency as quantified by IIEF-5. Mean age in the group Clavien-Dindo III) were found in 1.6% vs. 1.3% (≥75) of cases. Minor complications were encountered in 22.8% vs. 26.3% (≥75). There was a remarkably high percentage of locally advanced disease (73.3% vs. 71.0%) in both groups. Patients ≥75 showed a tendency toward more aggressive cancer and more frequent nodal involvement; we found a higher percentage of R1-resections (19.5% vs. 30.4%, p < 0.05) and PSA relapse after 1 year (12.3% vs. 22.8%, p < 0.05). Twelve months pad-free continence rate (69.9% vs. 63.2%) showed no statistically significant difference between both groups as did the preservation rate of erectile function. We could show that robotic prostatectomy can be carried out safely with good functional and histopathological results in patients ≥75. It is therefore questionable if elderly patients can be precluded from curative radical treatment solely because of their age.

  12. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    Science.gov (United States)

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  13. Systematic review and cumulative analysis of perioperative outcomes and complications after robot-assisted radical cystectomy

    DEFF Research Database (Denmark)

    Novara, Giacomo; Catto, James W F; Wilson, Timothy

    2015-01-01

    and complications of RARC in comparison with ORC and LRC. EVIDENCE ACQUISITION: Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies...

  14. Robotic assisted radical prostatectomy: a different treatment for prostate cancer?

    Directory of Open Access Journals (Sweden)

    Alexandre Den Julio

    2010-09-01

    Full Text Available Considering the Health Care System in Brazil, a developing country,and public healthcare policies, robotic surgery is a reality to veryfew citizens. Therefore, robotic assisted radical prostatectomy isfar removed from the daily practice of the vast majority of Brazilianurologists. Scientific evidence of the superiority of robotic assistedradical prostatectomy does not presently justify public investmentsfor widespread development of robotic centers. Maybe over timeand with reductions in costs, robotic technology will become amore established practice, as observed in other countries, and morefeasible for the Brazilian urological community.

  15. Anastomotic complications after robot-assisted laparoscopic and open radical prostatectomy

    DEFF Research Database (Denmark)

    Jacobsen, André; Berg, Kasper Drimer; Iversen, Peter

    2016-01-01

    Objective Anastomotic complications are well known after radical prostatectomy (RP). The vesicourethral anastomotic technique is handled differently between open and robotic RP. The aim of the study was to investigate whether the frequency of anastomotic leakages and strictures differed between...... patients undergoing retropubic radical prostatectomy (RRP) and robot-assisted radical prostatectomy (RARP) and to identify risk factors associated with these complications. Materials and methods The study included 735 consecutive patients who underwent RRP (n = 499) or RARP (236) at the Department...... of Urology, Rigshospitalet, Denmark, in a complete 3 year period from 2010 to 2012. Univariate and multivariate logistic regression analysis was used to analyse associations between surgical procedure (RRP vs RARP) and anastomotic complications. Analyses included age, smoking status, diabetes, hypertension...

  16. Robotic Radical Cystectomy: Where are We Today, Where will We be Tomorrow?

    Directory of Open Access Journals (Sweden)

    Kyle A. Richards

    2010-01-01

    Full Text Available While open radical cystectomy remains the gold-standard treatment for muscle-invasive bladder cancer and high-risk non–muscle invasive disease, robotic assisted radical cystectomy (RARC has been gaining popularity over the past decade. The robotic approach has the potential advantages of less intraoperative blood loss, shorter hospital stay, less post-operative narcotic requirement, quicker return of bowel function, and earlier convalescence with an acceptable surgical learning curve for surgeons adept at robotic radical prostatectomy. While short to intermediate term oncologic results from several small RARC series are promising, bladder cancer remains a potentially lethal malignancy necessitating long-term follow-up. This article aims to review the currently published literature, important technical aspects of the operation, oncologic and functional outcomes, and the future direction of RARC.

  17. Advances in Robotic-Assisted Radical Prostatectomy over Time

    Directory of Open Access Journals (Sweden)

    Emma F. P. Jacobs

    2013-01-01

    Full Text Available Since the introduction of robot-assisted radical prostatectomy (RALP, robotics has become increasingly more commonplace in the armamentarium of the urologic surgeon. Robotic utilization has exploded across surgical disciplines well beyond the fields of urology and prostate surgery. The literature detailing technical steps, comparison of large surgical series, and even robotically focused randomized control trials are available for review. RALP, the first robot-assisted surgical procedure to achieve widespread use, has recently become the primary approach for the surgical management of localized prostate cancer. As a result, surgeons are constantly trying to refine and improve upon current technical aspects of the operation. Recent areas of published modifications include bladder neck anastomosis and reconstruction, bladder drainage, nerve sparing approaches and techniques, and perioperative and postoperative management including penile rehabilitation. In this review, we summarize recent advances in perioperative management and surgical technique for RALP.

  18. Impact of metabolic syndrome on early recovery of continence after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Nishikawa, Masatomo; Watanabe, Hiromitsu; Kurahashi, Toshifumi

    2017-09-01

    To evaluate the impact of metabolic syndrome on the early recovery of urinary continence after robot-assisted radical prostatectomy. The present study included a total of 302 consecutive Japanese patients with clinically localized prostate cancer who underwent robot-assisted radical prostatectomy. In this study, postoperative urinary continence was defined as no leak or the use of a security pad. The continence status was assessed by interviews before and 1 and 3 months after robot-assisted radical prostatectomy. Metabolic syndrome was defined as follows: body mass index ≥25 kg/m 2 and two or more of the following: hypertension, diabetes mellitus and dyslipidemia. The effect of the presence of metabolic syndrome on the continence status of these patients was retrospectively examined. A total of 116 (38.4%) and 203 (67.2%) of the 302 patients were continent at 1 and 3 months after robot-assisted radical prostatectomy, respectively. A total of 31 (10.3%) patients were judged to have metabolic syndrome. Despite the operative time being longer in patients with metabolic syndrome, no significant differences were observed in the remaining preoperative, intraoperative or postoperative variables between patients with or without metabolic syndrome. On multivariate logistic regression analysis, metabolic syndrome and the duration of hospitalization were significantly correlated with the 1-month continence status. Similarly, metabolic syndrome and estimated blood loss during surgery were independent predictors of continence rates at 3 months after robot-assisted radical prostatectomy. These findings suggest that the presence of metabolic syndrome could have a significant impact on the early recovery of urinary continence after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  19. Robots drive the German radical prostatectomy market: a total population analysis from 2006 to 2013.

    Science.gov (United States)

    Groeben, C; Koch, R; Baunacke, M; Wirth, M P; Huber, J

    2016-12-01

    To assess trends in the distribution of patients for radical prostatectomy in Germany from 2006 to 2013 and the impact of robotic surgery on annual caseloads. We hypothesized that the advent of robotics and the establishment of certified prostate cancer centers caused centralization in the German radical prostatectomy market. Using remote data processing we analyzed the nationwide German billing data from 2006 to 2013. We supplemented this database with additional hospital characteristics like the prostate cancer center certification status. Inclusion criteria were a prostate cancer diagnosis combined with radical prostatectomy. Hospitals with certification or a surgical robot in 2009 were defined as 'early' group. Linear covariant-analytic models were applied to describe trends over time. Annual radical prostatectomy numbers declined from 28 374 (2006) to 21 850 (2013). High-volume hospitals (⩾100 cases) decreased from 87 (22.0%) in 2006 to 43 (10.4%) in 2013. Low-volume hospitals (200 cases per year contrary to the overall trend (Pdecentralization of radical prostatectomy in Germany. The driving force for this development might consist in the overall decline of radical prostatectomy numbers. The most important factor for achieving higher caseloads was the presence of a robotic system. In order to optimize outcomes of radical prostatectomy additional health policy measures might be necessary.

  20. What if the hand piece spring disassembles during robotic radical prostatectomy?

    Science.gov (United States)

    Akbulut, Ziya; Canda, Abdullah Erdem; Atmaca, Ali Fuat; Asil, Erem; Isgoren, Egemen; Balbay, Mevlana Derya

    2011-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is successfully being performed for treating prostate cancer (PCa). However, instrumentation failure associated with robotic procedures represents a unique new problem. We report the successful completion of RALRP in spite of a disassembled hand piece spring during the procedure. A PubMed/Medline search was made concerning robotic malfunction and robot-assisted laparoscopic radical prostatectomy to discuss our experience. We performed RALRP in a 60-year-old male patient with localized PCa. During the procedure, the spring of the hand piece disassembled, and we were not able to reassemble it. We completed the procedure successfully however without fixing the disassembled hand piece spring. We were able to grasp tissue and needles when we brought our fingers together. The only movement we needed to do was to move fingers apart to release tissue or needles caught by robotic instrument. Although malfunction risk related to the da Vinci Surgical System seems to be very low, it might still occur. Sometimes, simple maneuvers may compensate for the failed function as occurred in our case. However, patients should be informed before the operation about the possibility of converting their procedure to laparoscopic or open due to robotic malfunction.

  1. Erectile dysfunction in robotic radical prostatectomy: Outcomes and management

    Directory of Open Access Journals (Sweden)

    Patrick Whelan

    2014-01-01

    Full Text Available Robot-assisted laparoscopic prostatectomy (RALP has emerged as the most common treatment for localized prostate cancer. With improved surgical precision, RALP has produced hope of improved potency rates, especially with the advent of nerve-sparing and other modified techniques. However, erectile dysfunction (ED remains a significant problem for many men regardless of surgical technique. To identify the functional outcomes of robotic versus open and laparoscopic techniques, new robotic surgical techniques and current treatment options of ED following RALP. A Medline search was performed in March 2014 to identify studies comparing RALP with open retropubic radical prostatectomy (RRP and laparoscopic radical prostatectomy, modified RALP techniques and treatment options and management for ED following radical prostatectomy. RALP demonstrates adequate potency rates without compromising oncologic benefit, with observed benefit for potency rates compared with RRP. Additionally, specific surgical technical modifications appear to provide benefit over traditional RALP. Phosphodiesterase-5 inhibitors (PDE5I demonstrate benefit for ED treatment compared with placebo. However, long-term benefit is often lost after use. Other therapies have been less extensively studied. Additionally, correct patient identification is important for greatest clinical benefit. RALP appears to provide beneficial potency rates compared with RRP; however, these effects are most pronounced at high-volume centers with experienced surgeons. No optimal rehabilitation program with PDE5Is has been identified based on current data. Additionally, vacuum erection devices, intracavernosal injections and other techniques have not been well validated for post RALP ED treatment.

  2. Laparoscopic, robotic and open method of radical hysterectomy for cervical cancer: A systematic review

    Directory of Open Access Journals (Sweden)

    Puliyath Geetha

    2012-01-01

    Full Text Available Background : Over the last two decades, numerous studies have indicated the feasibility of minimally invasive surgery for early cervical cancer without compromising the oncological outcome. Objective : Systematic literature review and meta analysis aimed at evaluating the outcome of laparoscopic and robotic radical hysterectomy (LRH and RRH and comparing the results with abdominal radical hysterectomy (ARH. Search Strategy : Medline, PubMed, Embase, Cochrane library and Reference lists were searched for articles published until January 31 st 2011, using the terms radical hysterectomy, laparoscopic radical hysterectomy, robotic radical hysterectomy, surgical treatment of cervical cancer and complications of radical hysterectomy. Selection Criteria : Studies that reported outcome measures of radical hysterectomy by open method, laparoscopic and robotic methods were selected. Data collection and analysis: Two independent reviewers selected studies, abstracted and tabulated the data and pooled estimates were obtained on the surgical and oncological outcomes. Results : Mean sample size, age and body mass index across the three types of RH studies were similar. Mean operation time across the three types of RH studies was comparable. Mean blood loss and transfusion rate are significantly higher in ARH compared to both LRH and RRH. Duration of stay in hospital for RRH was significantly less than the other two methods. The mean number of lymph nodes obtained, nodal metastasis and positive margins across the three types of RH studies were similar. Post operative infectious morbidity was significantly higher among patients who underwent ARH compared to the other two methods and a higher rate of cystotomy in LRH. Conclusions : Minimally invasive surgery especially robotic radical hysterectomy may be a better and safe option for surgical treatment of cervical cancer. The laparoscopic method is not free from complications. However, experience of surgeon may

  3. Tandem-robot assisted laparoscopic radical prostatectomy to improve the neurovascular bundle visualization: a feasibility study.

    Science.gov (United States)

    Han, Misop; Kim, Chunwoo; Mozer, Pierre; Schäfer, Felix; Badaan, Shadie; Vigaru, Bogdan; Tseng, Kenneth; Petrisor, Doru; Trock, Bruce; Stoianovici, Dan

    2011-02-01

    To examine the feasibility of image-guided navigation using transrectal ultrasound (TRUS) to visualize the neurovascular bundle (NVB) during robot-assisted laparoscopic radical prostatectomy (RALP). The preservation of the NVB during radical prostatectomy improves the postoperative recovery of sexual potency. The accompanying blood vessels in the NVB can serve as a macroscopic landmark to localize the microscopic cavernous nerves in the NVB. A novel, robotic transrectal ultrasound probe manipulator (TRUS Robot) and three-dimensional (3-D) reconstruction software were developed and used concurrently with the daVinci surgical robot (Intuitive Surgical, Inc., Sunnyvale, CA) in a tandem-robot assisted laparoscopic radical prostatectomy (T-RALP). After appropriate approval and informed consent were obtained, 3 subjects underwent T-RALP without associated complications. The TRUS Robot allowed a steady handling and remote manipulation of the TRUS probe during T-RALP. It also tracked the TRUS probe position accurately and allowed 3-D image reconstruction of the prostate and surrounding structures. Image navigation was performed by observing the tips of the daVinci surgical instruments in the live TRUS image. Blood vessels in the NVB were visualized using Doppler ultrasound. Intraoperative 3-D image-guided navigation in T-RALP is feasible. The use of TRUS during radical prostatectomy can potentially improve the visualization and preservation of the NVB. Further studies are needed to assess the clinical benefit of T-RALP. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Impact of robotic technique and surgical volume on the cost of radical prostatectomy.

    Science.gov (United States)

    Hyams, Elias S; Mullins, Jeffrey K; Pierorazio, Phillip M; Partin, Alan W; Allaf, Mohamad E; Matlaga, Brian R

    2013-03-01

    Our present understanding of the effect of robotic surgery and surgical volume on the cost of radical prostatectomy (RP) is limited. Given the increasing pressures placed on healthcare resource utilization, such determinations of healthcare value are becoming increasingly important. Therefore, we performed a study to define the effect of robotic technology and surgical volume on the cost of RP. The state of Maryland mandates that all acute-care hospitals report encounter-level and hospital discharge data to the Health Service Cost Review Commission (HSCRC). The HSCRC was queried for men undergoing RP between 2008 and 2011 (the period during which robot-assisted laparoscopic radical prostatectomy [RALRP] was coded separately). High-volume hospitals were defined as >60 cases per year, and high-volume surgeons were defined as >40 cases per year. Multivariate regression analysis was performed to evaluate whether robotic technique and high surgical volume impacted the cost of RP. There were 1499 patients who underwent RALRP and 2565 who underwent radical retropubic prostatectomy (RRP) during the study period. The total cost for RALRP was higher than for RRP ($14,000 vs 10,100; Probotic surgery has come to dominate the healthcare marketplace, strategies to increase the role of high-volume providers may be needed to improve the cost-effectiveness of prostate cancer surgical therapy.

  5. Robotic radical cystectomy and intracorporeal urinary diversion: The USC technique.

    Science.gov (United States)

    Abreu, Andre Luis de Castro; Chopra, Sameer; Azhar, Raed A; Berger, Andre K; Miranda, Gus; Cai, Jie; Gill, Inderbir S; Aron, Monish; Desai, Mihir M

    2014-07-01

    Radical cystectomy is the gold-standard treatment for muscle-invasive and refractory nonmuscle-invasive bladder cancer. We describe our technique for robotic radical cystectomy (RRC) and intracorporeal urinary diversion (ICUD), that replicates open surgical principles, and present our preliminary results. Specific descriptions for preoperative planning, surgical technique, and postoperative care are provided. Demographics, perioperative and 30-day complications data were collected prospectively and retrospectively analyzed. Learning curve trends were analyzed individually for ileal conduits (IC) and neobladders (NB). SAS(®) Software Version 9.3 was used for statistical analyses with statistical significance set at P < 0.05. Between July 2010 and September 2013, RRC and lymph node dissection with ICUD were performed in 103 consecutive patients (orthotopic NB=46, IC 57). All procedures were completed robotically replicating the open surgical principles. The learning curve trends showed a significant reduction in hospital stay for both IC (11 vs. 6-day, P < 0.01) and orthotopic NB (13 vs. 7.5-day, P < 0.01) when comparing the first third of the cohort with the rest of the group. Overall median (range) operative time and estimated blood loss was 7 h (4.8-13) and 200 mL (50-1200), respectively. Within 30-day postoperatively, complications occurred in 61 (59%) patients, with the majority being low grade (n = 43), and no patient died. Median (range) nodes yield was 36 (0-106) and 4 (3.9%) specimens had positive surgical margins. Robotic radical cystectomy with totally ICUD is safe and feasible. It can be performed using the established open surgical principles with encouraging perioperative outcomes.

  6. Application of da Vinci(®) Robot in simple or radical hysterectomy: Tips and tricks.

    Science.gov (United States)

    Iavazzo, Christos; Gkegkes, Ioannis D

    2016-01-01

    The first robotic simple hysterectomy was performed more than 10 years ago. These days, robotic-assisted hysterectomy is accepted as an alternative surgical approach and is applied both in benign and malignant surgical entities. The two important points that should be taken into account to optimize postoperative outcomes in the early period of a surgeon's training are how to achieve optimal oncological and functional results. Overcoming any technical challenge, as with any innovative surgical method, leads to an improved surgical operation timewise as well as for patients' safety. The standardization of the technique and recognition of critical anatomical landmarks are essential for optimal oncological and clinical outcomes on both simple and radical robotic-assisted hysterectomy. Based on our experience, our intention is to present user-friendly tips and tricks to optimize the application of a da Vinci® robot in simple or radical hysterectomies.

  7. [Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2015-08-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of hospitals was 63%, though it marginally varied according to type and area. The annual case load was determined based on the results of the questionnaire and other modalities. It increased from 3,518 in 2009 to 6,425 in 2013. The case load seemed to be concentrated in hospitals with robot equipment since the increase of their number was very minimal over the 5 years. The hospitals with the robot treated a larger number of newly diagnosed patients with the disease than before. Most of the patients were those having localized cancer that was indicated for radical surgery, suggesting again the concentration of the surgical case loads in the hospitals with robots. While most hospitals believed that installation of a robot was necessary as an option for treatment procedures, the future strategy of the hospital, and other reasons, the action of the hospital to gain prestige may be involved in the process of purchasing the equipment. In conclusion, robot-assisted laparoscopic radical prostatectomy has become popular as a surgical procedure for prostate cancer in our society. This may lead to a concentration of the surgical case load in a limited number of hospitals with robots. We also discuss the typical action of an acute-care hospital when it purchases expensive clinical medical equipment.

  8. Robotic-assisted transperitoneal radical prostatectomy in a patient with pelvic kidney

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Alyami, Fahad A.

    2008-01-01

    Robots are increasingly utilized in urology, due to their favorable performance characteristics especially in prostatectomy and pyeloplasty. However, preoperative diagnosis of urogenital congenital anomalies and preoperative planning are important aspects to be considered. The presence of ectopic pelvic kidney is a challenge for the surgeon to perform robotic-assisted radical prostatectomy (RARP) without injury to the pelvic kidney (PC) or its blood supply. We report our experience of performing RARP in a patient with a PK. (author)

  9. Robotic radical cystectomy and intracorporeal urinary diversion: The USC technique

    Directory of Open Access Journals (Sweden)

    Andre Luis de Castro Abreu

    2014-01-01

    Full Text Available Introduction: Radical cystectomy is the gold-standard treatment for muscle-invasive and refractory nonmuscle-invasive bladder cancer. We describe our technique for robotic radical cystectomy (RRC and intracorporeal urinary diversion (ICUD, that replicates open surgical principles, and present our preliminary results. Materials and Methods: Specific descriptions for preoperative planning, surgical technique, and postoperative care are provided. Demographics, perioperative and 30-day complications data were collected prospectively and retrospectively analyzed. Learning curve trends were analyzed individually for ileal conduits (IC and neobladders (NB. SAS ® Software Version 9.3 was used for statistical analyses with statistical significance set at P < 0.05. Results: Between July 2010 and September 2013, RRC and lymph node dissection with ICUD were performed in 103 consecutive patients (orthotopic NB=46, IC 57. All procedures were completed robotically replicating the open surgical principles. The learning curve trends showed a significant reduction in hospital stay for both IC (11 vs. 6-day, P < 0.01 and orthotopic NB (13 vs. 7.5-day, P < 0.01 when comparing the first third of the cohort with the rest of the group. Overall median (range operative time and estimated blood loss was 7 h (4.8-13 and 200 mL (50-1200, respectively. Within 30-day postoperatively, complications occurred in 61 (59% patients, with the majority being low grade (n = 43, and no patient died. Median (range nodes yield was 36 (0-106 and 4 (3.9% specimens had positive surgical margins. Conclusions: Robotic radical cystectomy with totally ICUD is safe and feasible. It can be performed using the established open surgical principles with encouraging perioperative outcomes.

  10. Intraoperative registered transrectal ultrasound guidance for robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Mohareri, Omid; Ischia, Joseph; Black, Peter C; Schneider, Caitlin; Lobo, Julio; Goldenberg, Larry; Salcudean, Septimiu E

    2015-01-01

    To provide unencumbered real-time ultrasound image guidance during robot-assisted laparoscopic radical prostatectomy, we developed a robotic transrectal ultrasound system that tracks the da Vinci® Surgical System instruments. We describe our initial clinical experience with this system. After an evaluation in a canine model, 20 patients were enrolled in the study. During each procedure the transrectal ultrasound transducer was manually positioned using a brachytherapy stabilizer to provide good imaging of the prostate. Then the transrectal ultrasound was registered to the da Vinci robot by a previously validated procedure. Finally, automatic rotation of the transrectal ultrasound was enabled such that the transrectal ultrasound imaging plane safely tracked the tip of the da Vinci instrument controlled by the surgeon, while real-time transrectal ultrasound images were relayed to the surgeon at the da Vinci console. Tracking was activated during all critical stages of the surgery. The transrectal ultrasound robot was easy to set up and use, adding 7 minutes (range 5 to 14) to the procedure. It did not require an assistant or additional control devices. Qualitative feedback was acquired from the surgeons, who found transrectal ultrasound useful in identifying the urethra while passing the dorsal venous complex suture, defining the prostate-bladder interface during bladder neck dissection, identifying the seminal vesicles and their location with respect to the rectal wall, and identifying the distal prostate boundary at the apex. Real-time, registered robotic transrectal ultrasound guidance with automatic instrument tracking during robot-assisted laparoscopic radical prostatectomy is feasible and potentially useful. The results justify further studies to establish whether the approach can improve procedure outcomes. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. The financial impact of robotic technology for partial and radical nephrectomy.

    Science.gov (United States)

    Kates, Max; Ball, Mark W; Patel, Hiten D; Gorin, Michael A; Pierorazio, Phillip M; Allaf, Mohamad E

    2015-03-01

    We sought to evaluate the financial impact of robotic technology for partial nephrectomy (PN) and radical nephrectomy (RN) in the state of Maryland. The Maryland Health Services Cost Review Commission (HSCRC) documents all acute care hospital charges data. This database was queried for patients who underwent laparoscopic or robot-assisted RN and PN from 2008 to 2012. Total hospital charge, subcharge, and length of stay (LOS) were analyzed separately for RN and PN. Overall, 2834 patients were identified. Of those, 282 were laparoscopic PN (LPN), 1078 robot-assisted PN (RPN), 1098 laparoscopic RN (LRN), and 376 robot-assisted RN (RRN). For PN, the total hospital charge was $19,062 for LPN and $18,255 for RPN (P=0.138), with a charge savings of $807 per case in favor of robotics. For RN, the total hospital charge was $23,391 for RRN and $18,280 for LRN (P=0.004), with a charge premium of $5111 for robotic cases. LOS was shorter for RPN compared with LPN (2.51 vs 2.99 days, Pfinancial implications of RRN use for routine cases warrants further study.

  12. Cost analysis of open radical cystectomy versus robot-assisted radical cystectomy.

    Science.gov (United States)

    Bansal, Sukhchain S; Dogra, Tara; Smith, Peter W; Amran, Maisarah; Auluck, Ishna; Bhambra, Maninder; Sura, Manraj S; Rowe, Edward; Koupparis, Anthony

    2018-03-01

    To perform a cost analysis comparing the cost of robot-assisted radical cystectomy (RARC) with open RC (ORC) in a UK tertiary referral centre and to identify the key cost drivers. Data on hospital length of stay (LOS), operative time (OT), transfusion rate, and volume and complication rate were obtained from a prospectively updated institutional database for patients undergoing RARC or ORC. A cost decision tree model was created. Sensitivity analysis was performed to find key drivers of overall cost and to find breakeven points with ORC. Monte Carlo analysis was performed to quantify the variability in the dataset. One RARC procedure costs £12 449.87, or £12 106.12 if the robot was donated via charitable funds. In comparison, one ORC procedure costs £10 474.54. RARC is 18.9% more expensive than ORC. The key cost drivers were OT, LOS, and the number of cases performed per annum. High ongoing equipment costs remain a large barrier to the cost of RARC falling. However, minimal improvements in patient quality of life would be required to offset this difference. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  13. Titanocene(III) chloride mediated radical induced addition ...

    Indian Academy of Sciences (India)

    Reduction of the aldehyde 10 with sodium boro- hydride in the presence of CeCl3.7H2O furnished the alcohol 11 which was finally brominated using PBr3 to yield the dibromo compound 12.13. Thus, a series of bromoepoxides were prepared and subjected to radical cyclization using titanocene(III) chloride and the results ...

  14. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects.

    Science.gov (United States)

    Mota Filho, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo; Passerotti, Carlo

    2018-01-01

    Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1-3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using na 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Copyright® by the International Brazilian Journal of Urology.

  15. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects

    Directory of Open Access Journals (Sweden)

    Francisco Hidelbrando Alves Mota Filho

    Full Text Available ABSTRACT Introduction Robot-Assisted Single Site Radical Nephrectomy (RASS-RN has been reported by surgeons in Europe and United States (1–3. To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. Case A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Results Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Discussion Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2. Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. Conclusion RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology.

  16. The "halo effect" in Korea: change in practice patterns since the introduction of robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sung, Ee-Rah; Jeong, Wooju; Park, Sung Yul; Ham, Won Sik; Choi, Young Deuk; Hong, Sung Joon; Rha, Koon Ho

    2009-03-01

    Acquisition of the da Vinci surgical system (Intuitive Surgical, Mountain View, USA) has enabled robot-assisted surgery to become an acceptable alternative to open radical prostatectomy (ORP). Implementation of robotics at a single institution in Korea induced a gradual increase in the number of performances of robot-assisted laparoscopic radical prostatectomy (RALP) to surgically treat localized prostate cancer. We analyzed the impact of robotic instrumentation on practice patterns among urologists and explain the change in value in ORP and RALP-the standard treatment and the new approach or innovation of robotic technology. The overall number of prostatectomies has increased over time because the number of RALPs has grown drastically whereas the number of OPRs did not decrease during the period of evaluation. Our experience emphasizes the potential of RALP to become the gold standard in the treatment of localized prostate cancer in various parts of the world.

  17. Complications and health-related quality of life after robot-assisted versus open radical cystectomy

    DEFF Research Database (Denmark)

    Lauridsen, Susanne Vahr; Tønnesen, Hanne; Jensen, Bente Thoft

    2017-01-01

    Background: Radical cystectomy is associated with high rates of perioperative morbidity. Robotic-assisted radical cystectomy (RARC) is widely used today despite limited evidence for clinical superiority. The aim of this review was to evaluate the effect of RARC compared to open radical cystectomy...... (ORC) on complications and secondary on length of stay, time back to work and health-related quality of life (HRQoL). Methods: The databases PubMed, The Cochrane Library, Embase and CINAHL were searched. A systematic review according to the PRISMA guidelines and cumulative analysis was conducted...

  18. Odex III: building on the EPRI walking robot

    International Nuclear Information System (INIS)

    Guzowski, S.

    1991-01-01

    Odetics has delivered a second generation preproduction Odex TM III robot to the French Commissariat a l'Energie Atomique (CEA). The CEA version of the robot is an all electric-actuated six-legged machine that uses an alternating tripod gate as its normal walking mode, keeping three of its six feet on the walking surface at all times. The six legs are normally positioned symmetrically 60 o apart around the torso, allowing for movement in all directions. Each leg subsystem contains three servo motors and a sophisticated arrangements of gear reducers, ball screws and linkage mechanisms to produce three essential leg motions (vertical travel, radial extension and tangential or side-to-side swing). This means that the top of the transporter body can be as compact as 3.5 ft in height when the legs are fully retracted, or as tall as 6.5ft when they are fully extended. Odex III can manoeuvre through doorways or turn tight corners, and the side-to-side swing of the legs allows asymmetric leg positioning for moving in constricted spaces. Odex III's feet contain sensors to determine proper foot placement while walking. One sensor-assembly detects updown vertical loading and checks that the foot is placed on a solid surface. Another set of sensors detects both side loading on the foot and obstacles in a lateral direction. Each leg can exert a 1200lb extension force. Together they are capable of exerting 5500lb of vertical force. The CEA is currently using the system in the SHERPA project which aims to demonstrate the feasibility of a versatile, modular mobile robot system for Pressurized Water Reactor maintenance. (author)

  19. Feasibility of robotic radical prostatectomy for medication refractory chronic prostatitis/chronic pelvic pain syndrome: Initial results

    Directory of Open Access Journals (Sweden)

    Sameer Chopra

    2016-01-01

    Full Text Available Four patients diagnosed with chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS, met criteria for National Institute of Health (NIH Category III prostatitis, failed multiple medicinal treatments and underwent robotic radical prostatectomy (RRP. Median operative time (range: 157 (127–259 min. Validated functional questionnaires responses and NIH CP symptom index (NIH-CPSI score were collected for each patient's status at different time points pre- and post-operatively. Median decreases (range were: International Prostate Symptom Score - 14 (1–19; Sexual Health Inventory for Men - 6 (−14–22; and NIH-CPSI total - 23.5 (13–33. Median length of follow-up (range was 34 (24–43 months. RRP appears to be an option for carefully selected patients with medication-refractory CP/CPPS who understand that baseline sexual function may not be restored postoperatively.

  20. Robotic and open radical prostatectomy in the public health sector: cost comparison.

    Science.gov (United States)

    Hall, Rohan Matthew; Linklater, Nicholas; Coughlin, Geoff

    2014-06-01

    During 2008, the Royal Brisbane and Women's Hospital became the first public hospital in Australia to have a da Vinci Surgical Robot purchased by government funding. The cost of performing robotic surgery in the public sector is a contentious issue. This study is a single centre, cost analysis comparing open radical prostatectomy (RRP) and robotic-assisted radical prostatectomy (RALP) based on the newly introduced pure case-mix funding model. A retrospective chart review was performed for the first 100 RALPs and the previous 100 RRPs. Estimates of tangible costing and funding were generated for each admission and readmission, using the Royal Brisbane Hospital Transition II database, based on pure case-mix funding. The average cost for admission for RRP was A$13 605, compared to A$17 582 for the RALP. The average funding received for a RRP was A$11 781 compared to A$5496 for a RALP based on the newly introduced case-mix model. The average length of stay for RRP was 4.4 days (2-14) and for RALP, 1.2 days (1-4). The total cost of readmissions for RRP patients was A$70 487, compared to that of the RALP patients, A$7160. These were funded at A$55 639 and A$7624, respectively. RALP has shown a significant advantage with respect to length of stay and readmission rate. Based on the case-mix funding model RALP is poorly funded compared to its open equivalent. Queensland Health needs to plan on how robotic surgery is implemented and assess whether this technology is truly affordable in the public sector. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  1. Robot-assisted radical cystectomy with intracorporeal neobladder diversion: The Karolinska experience.

    Science.gov (United States)

    Collins, Justin W; Sooriakumaran, P; Sanchez-Salas, R; Ahonen, R; Nyberg, T; Wiklund, N P; Hosseini, A

    2014-07-01

    The aim of this report is to describe our surgical technique of totally intracorporeal robotic assisted radical cystectomy (RARC) with neobladder formation. Between December 2003 and March 2013, a total of 147 patients (118 male, 29 female) underwent totally intracorporeal RARC for urinary bladder cancer. We also performed a systematic search of Medline, Embase and PubMed databases using the terms RARC, robotic cystectomy, robot-assisted, totally intracorporeal RARC, intracorporeal neobladder, intracorporeal urinary diversion, oncological outcomes, functional outcomes, and complication rates. The mean age of our patients was 64 years (range 37-87). On surgical pathology 47% had pT1 or less disease, 27% had pT2, 16% had pT3 and 10% had pT4. The mean number of lymph nodes removed was 21 (range 0-60). 24% of patients had lymph node positive dAQ1isease. Positive surgical margins occurred in 6 cases (4%). Mean follow-up was 31 months (range 4-115 months). Two patients (1.4%) died within 90 days of their operation. Using Kaplan-Meier analysis, overall survival and cancer specific survival at 60 months was 68% and 69.6%, respectively. 80 patients (54%) received a continent diversion with totally intracorporeal neobladder formation. In the neobladder subgroup median total operating time was 420 minutes (range 265-760). Daytime continence and satisfactory sexual function or potency at 12 months ranged between 70-90% in both men and women. Our experience with totally intracorporeal RARC demonstrates acceptable oncological and functional outcomes that suggest this is a viable alternative to open radical cystectomy.

  2. Robot-assisted radical cystoprostatectomy: Analysis of the complications and oncological and functional aspects.

    Science.gov (United States)

    Kanashiro, A; Gaya, J M; Palou, J; Gausa, L; Villavicencio, H

    2017-05-01

    To review our experience in robot-assisted radical cystectomy, assessing the complications and oncological and functional results. From 2007 to 2014, we performed 67 robot-assisted radical cystectomies combined with lymphadenectomy in 61 cases. The operations were performed on 37 patients due to muscle-invasive tumours and on 30 due to high-risk nonmuscle-invasive tumours. Urinary diversion was conducted extracorporeally, using a Studer neobladder in 47 cases. The mean blood loss was 300mL. No case required conversion to open surgery. The median number of lymph nodes extracted was 16 (range 3-33). Pathology revealed 16 pT0, 15 pTis,-pT1-pTa and 44 muscle-invasive tumours, 8 pN+ and 1 with positive margins. The mean hospital stay was 9 days. With a median follow-up of 16 months, 9 (13%) patients were readmitted after the discharge, most for infections associated with the vesical catheter and other catheters. Forty patients (59.7%) presented complications (most were Clavien grade 1-2). There was recurrence during the follow-up in 4 cases (6%), and 4 (5.9%) patients died from cancer. Nineteen (28.3%) patients had complications after 30 days, most of which were urinary tract infections. Of the 47 patients with a neobladder, 45 (96%) had proper daytime continence and 42 (89%) had proper nighttime continence. Ninety percent and 64% of the patients with previously normal sexual function and reduced sexual function, respectively, were able to preserve sexual function with or without drug treatment. Robot-assisted radical cystectomy plus lymphadenectomy, with extracorporeal reconstruction of the urinary diversion, offers good oncological and functional results without increasing the number of complications. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Trends in radical prostatectomy: centralization, robotics, and access to urologic cancer care.

    Science.gov (United States)

    Stitzenberg, Karyn B; Wong, Yu-Ning; Nielsen, Matthew E; Egleston, Brian L; Uzzo, Robert G

    2012-01-01

    Robotic surgery has been widely adopted for radical prostatectomy. We hypothesized that this change is rapidly shifting procedures away from hospitals that do not offer robotics and consequently increasing patient travel. A population-based observational study of all prostatectomies for cancer in New York, New Jersey, and Pennsylvania from 2000 to 2009 was performed using hospital discharge data. Hospital procedure volume was defined as the number of prostatectomies performed for cancer in a given year. Straight-line travel distance to the treating hospital was calculated for each case. Hospitals were contacted to determine the year of acquisition of the first robot. From 2000 to 2009, the total number of prostatectomies performed annually increased substantially. The increase occurred almost entirely at the very high-volume centers (≥ 106 prostatectomies/year). The number of hospitals performing prostatectomy fell 37% from 2000 to 2009. By 2009, the 9% (21/244) of hospitals that had very high volume performed 57% of all prostatectomies, and the 35% (86/244) of hospitals with a robot performed 85% of all prostatectomies. The median travel distance increased 54% from 2000 to 2009 (Probotic surgery. Copyright © 2011 American Cancer Society.

  4. Radical nephrectomy performed by open, laparoscopy with or without hand-assistance or robotic methods by the same surgeon produces comparable perioperative results

    Directory of Open Access Journals (Sweden)

    Tanya Nazemi

    2006-02-01

    Full Text Available PURPOSE: Radical nephrectomy can be performed using open or laparoscopic (with or without hand assistance methods, and most recently using the da Vinci Surgical Robotic System. We evaluated the perioperative outcomes using a contemporary cohort of patients undergoing radical nephrectomy by one of the above 4 methods performed by the same surgeon. MATERIALS AND METHODS: The relevant clinical information on 57 consecutive patients undergoing radical nephrectomy from September 2000 until July 2004 by a single surgeon was entered in a Microsoft Access DatabaseTM and queried. Following appropriate statistical analysis, p values < 0.05 were considered significant. RESULTS: Of 57 patients, the open, robotic, laparoscopy with or without hand assistance radical nephrectomy were performed in 18, 6, 21, and 12 patients, respectively. The age, sex, body mass index (BMI, incidence of malignancy, specimen and tumor size, tumor stage, Fuhrman grade, hospital stay, change in postoperative creatinine, drop in hemoglobin, and perioperative complications were not significantly different between the methods. While the estimated median blood loss, postoperative narcotic use for pain control, and hospital stay were significantly higher in the open surgery method (p < 0.05, the median operative time was significantly shorter compared to the robotic method (p = 0.02. Operating room costs were significantly higher in the robotic and laparoscopic groups; however, there was no significant difference in total hospital costs between the 4 groups. CONCLUSIONS: The study demonstrates that radical nephrectomy can be safely performed either by open, robotic, or laparoscopic with or without hand assistance methods without significant difference in perioperative complication rates. A larger cohort and longer follow up are needed to validate our findings and establish oncological outcomes.

  5. Copolymers containing phosphorescent iridium(III) complexes obtained by free and controlled radical polymerization techniques

    NARCIS (Netherlands)

    Ulbricht, C.; Becer, C.R.; Winter, A.; Veldman, D.; Schubert, U.S.

    2008-01-01

    A methacrylate-functionalized phosphorescent Ir(III)-complex has been synthesized, characterized, and applied as a monomer in radical copolymerizations. Together with methyl methacrylate, the complex has been copolymerized under free radical polymerization conditions. Aiming for host-guest-systems,

  6. Magnetic Properties of linear chain compounds formed by lanthanide (III) ions and nitronyl-nitroxide radicals

    Energy Technology Data Exchange (ETDEWEB)

    Benelli, C.; Caneschi, A.; Gatteschi, D.; Pardi, L. (Florence Univ. (IT)); Rey, P. (CEA Centre d' Etudes Nucleaires de Grenoble, 38 (FR). Dept. de Recherche Fondamentale)

    1988-12-01

    The magnetic properties of novel linear chain compounds containing lanthanide (III) ions (gadolinium, europium) coupled to stable nitronyl-nitroxide radicals are reported. The metal ions and the radicals are regularly alternating along the chain. The magnetic behaviors appears to be dominated by antiferromagnetic interactions between the radicals.

  7. Magnetic Properties of linear chain compounds formed by lanthanide (III) ions and nitronyl-nitroxide radicals

    International Nuclear Information System (INIS)

    Benelli, C.; Caneschi, A.; Gatteschi, D.; Pardi, L.; Rey, P.

    1988-01-01

    The magnetic properties of novel linear chain compounds containing lanthanide (III) ions (gadolinium, europium) coupled to stable nitronyl-nitroxide radicals are reported. The metal ions and the radicals are regularly alternating along the chain. The magnetic behaviors appears to be dominated by antiferromagnetic interactions between the radicals

  8. Stratified analysis of 800 Asian patients after robot-assisted radical prostatectomy with a median 64 months of follow up.

    Science.gov (United States)

    Abdel Raheem, Ali; Kim, Dae Keun; Santok, Glen Denmer; Alabdulaali, Ibrahim; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2016-09-01

    To report the 5-year oncological outcomes of robot-assisted radical prostatectomy from the largest series ever reported from Asia. A retrospective analysis of 800 Asian patients who were treated with robot-assisted radical prostatectomy from July 2005 to May 2010 in the Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea was carried out. The primary end-point was to evaluate the biochemical recurrence. The secondary end-point was to show the biochemical recurrence-free survival, metastasis-free survival and cancer-specific survival. A total of 197 (24.65%), 218 (27.3%), and 385 (48.1%) patients were classified as low-, intermediate- and high-risk patients according to the D'Amico risk stratification risk criteria, respectively. The median follow-up period was 64 months (interquartile range 28-71 months). The overall incidence of positive surgical margin was 36.6%. There was biochemical recurrence in 183 patients (22.9%), 38 patients (4.8%) developed distant metastasis and 24 patients (3%) died from prostate cancer. Actuarial biochemical recurrence-free survival, metastasis-free survival, and cancer-specific survival rates at 5 years were 76.4%, 94.6% and 96.7%, respectively. Positive lymph node was associated with lower 5-year biochemical recurrence-free survival (9.1%), cancer-specific survival (75.7%) and metastasis-free survival (61.9%) rates (P < 0.001). On multivariable analysis, among all the predictors, positive lymph node was the strongest predictor of biochemical recurrence, cancer-specific survival and metastasis-free survival (P < 0.001). Herein we report the largest robot-assisted radical prostatectomy series from Asia. Robot-assisted radical prostatectomy is confirmed to be an oncologically safe procedure that is able to provide effective 5-year cancer control, even in patients with high-risk disease. © 2016 The Japanese Urological Association.

  9. A preliminary oncologic outcome and postoperative complications in patients undergoing robot-assisted radical cystectomy: Initial experience

    Directory of Open Access Journals (Sweden)

    Satoru Muto

    2017-05-01

    Full Text Available Purpose: Robot-assisted radical cystectomy (RARC was originally intended to replace open radical cystectomy (ORC as a minimally invasive surgery for patients with invasive bladder cancer. The purpose of this study was to evaluate the advantages of robotic surgery, comparing perioperative and oncologic outcomes between RARC and ORC. Materials and Methods: Between June 2012 and August 2016, 49 bladder cancer patients were given a radical cystectomy, 21 robotically and 28 by open procedure. We compared the clinical variables between the RARC and ORC groups. Results: In the RARC group, the median estimated blood loss (EBL during cystectomy, total EBL, operative time during cystectomy, and total operative time were 0 mL, 457.5 mL, 199 minutes, and 561 minutes, respectively. EBL during cystectomy (p<0.001, total EBL (p<0.001, and operative time during cystectomy (p=0.003 in the RARC group were significantly lower compared with the ORC group. Time to resumption of a regular diet (p<0.001 and length of stay (p=0.017 were also significantly shorter compared with the ORC group. However, total operative time in the RARC group (median, 561 minutes was significantly longer compared with the ORC group (median, 492.5 minutes; p=0.015. Conclusions: This Japanese study presented evidence that RARC yields benefits in terms of BL and time to regular diet, while consuming greater total operative time. RARC may be a minimally invasive surgical alternative to ORC with less EBL and shorter length of stay.

  10. A short-term cost-effectiveness study comparing robot-assisted laparoscopic and open retropubic radical prostatectomy

    DEFF Research Database (Denmark)

    Hohwü, Lena; Borre, Michael; Ehlers, Lars

    2011-01-01

    OBJECTIVE: To evaluate cost effectiveness and cost utility comparing robot-assisted laparoscopic prostatectomy (RALP) versus retropubic radical prostatectomy (RRP). METHODS: In a retrospective cohort study a total of 231 men between the age of 50 and 69 years and with clinically localised prostate....... An economic evaluation was made to estimate direct costs of the first postoperative year and an incremental cost-effectiveness ratio (ICER) per successful surgical treatment and per quality-adjusted life-year (QALY). A successful RP was defined as: no residual cancer (PSA ... high volume urology centres and utilise the full potential of each robot....

  11. Development of Vmax III. Magnetic wall climbing robot with holonomic and omni-directional mobility

    International Nuclear Information System (INIS)

    Tsuru, Kiyoshi; Hirose, Shigeo

    2012-01-01

    Wall-climbing robots having holonomic and omni-directional mobility would enhance the manipulation performance of the mounted arm and enable it to execute various tasks on the surface of large structures. This study focuses on the wall-climbing robots having permanent magnet attractive units to stick to the surface of iron structure such as atomic reactors and discuss the development of a specific holonomic and omni-directional wall-climbing mechanisms. Basic driving mechanism of the wall-climbing robot is based on our former invention named Omni Disk which consists of multiple rollers attached to one side of a rotating disk and having a mechanism to direct the rollers to the same direction. We firstly discuss about the mechanical improvements of the Omni Disk to make it lightweight and low cost. We next discusses about four types of methods to attach permanent magnets to the wall-climbing robot and generates attractive force on the iron wall and select the best type based on the motion experiments about the constructed models. As the result of these considerations, we developed a holonomic and omni-directional wall-climbing robot named Vmax III which consists of three Omni Disks having permanent magnet at their center having the function to change the magnetic attractive force. By using the Vmax III, we studied about the relation among the magnetic attractive force of three Omni Disks, posture of the Vmax III and inclination angle of the iron wall and clarified the optimized distribution of the magnetic attractive force of the Omni Disks in different inclination of the iron wall. (author)

  12. Percutaneous cystostomy drainage for early removing urethral catheter in robotic-assisted laparoscopic radical prostatectomy: Improving on patients' discomfort

    Directory of Open Access Journals (Sweden)

    Che-Jui Yang

    2015-12-01

    Conclusion: The use of a percutaneous cystostomy device is feasible and safe for the early removal of urethral Foley catheter in robotic-assisted laparoscopic radical prostatectomy to decrease penile pain and patient discomfort.

  13. Hemodynamic changes during robotic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Vanlal Darlong

    2012-01-01

    Full Text Available Background: Effect on hemodynamic changes and experience of robot-assisted laparoscopic radical prostatectomy (RALRP in steep Trendelenburg position (45° with high-pressure CO 2 pneumoperitoneum is very limited. Therefore, we planned this prospective clinical trial to study the effect of steep Tredelenburg position with high-pressure CO 2 pneumoperitoneum on hemodynamic parameters in a patient undergoing RALRP using FloTrac/Vigileo™1.10. Methods: After ethical approval and informed consent, 15 patients scheduled for RALRP were included in the study. In the operation room, after attaching standard monitors, the radial artery was cannulated. Anesthesia was induced with fentanyl (2 μg/kg and thiopentone (4-7 mg/kg, and tracheal intubation was facilitated by vecuronium bromide (0.1 mg/kg. The patient′s right internal jugular vein was cannulated and the Pre Sep™ central venous oximetry catheter was connected to it. Anesthesia was maintained with isoflurane in oxygen and nitrous oxide and intermittent boluses of vecuronium. Intermittent positive-pressure ventilation was provided to maintain normocapnea. After CO 2 pneumoperitoneum, position of the patient was gradually changed to 45° Trendelenburg over 5 min. The robot was then docked and the robot-assisted surgery started. Intraoperative monitoring included central venous pressure (CVP, stroke volume (SV, stroke volume variation (SVV, cardiac output (CO, cardiac index (CI and central venous oxygen saturation (ScvO 2 . Results: After induction of anesthesia, heart rate (HR, SV, CO and CI were decreased significantly from the baseline value (P>0.05. SV, CO and CI further decreased significantly after creating pneumoperitoneum (P>0.05. At the 45° Trendelenburg position, HR, SV, CO and CI were significantly decreased compared with baseline. Thereafter, CO and CI were persistently low throughout the 45° Trendelenburg position (P=0.001. HR at 20 min and 1 h, SV and mean arterial blood pressure

  14. The new era of minimally invasive interventions for prostate cancer: robot-assisted laparoscopic radical prostatectomy and focal therapy

    Directory of Open Access Journals (Sweden)

    Schatloff O

    2011-10-01

    Full Text Available Oscar Schatloff1, Alyssa S Louis2, Uri Lindner21Global Robotics Institute, Florida Hospital Celebration Health, Celebration, FL, USA; 2Division of Urology, Department of Surgical Oncology, University Health Network, Toronto, ON, CanadaAbstract: Prostate cancer remains a common but highly treatable disease. Innovations in prostate cancer treatment have allowed a transition toward minimally invasive approaches in an attempt to avoid treatment-related morbidities. In the middle of the treatment spectrum between radical open surgeries and active surveillance lies robot-assisted laparoscopic radical prostatectomy (RALP and focal therapy (FT. This review sets out the most current information on RALP and FT (including laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, and irreversible electroporation.Keywords: PCa, RALP, FT, laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, irreversible electroporation

  15. Single plus one port robotic radical prostatectomy (SPORP; Initial experience

    Directory of Open Access Journals (Sweden)

    Volkan Tugcu

    2017-10-01

    Full Text Available Objective: This article reports on patients with early stage prostate cancer treated with single plus one port robotic radical prostatectomy (SPORP. Materials and methods: Since January 2014, we performed SPORP in 8 patients with localized prostate cancer. Age of patients, clinical stage, operation time, intraoperative and postoperative complications, blood loss, histopathological evaluation, postoperative continence, serum level of PSA were evaluated. Results: Mean age of the 8 patients was 59.85 years. All operations were completed without conversion to standard robotic procedure or open surgery. No intra operative complications occurred. Mean operating time was 143 minutes; prostate excision 123 minutes and urethrovesical anastomosis 20 minutes. Mean blood loss was 45 ml. Preoperative Gleason scores were (3 + 4 in one patient and (3 + 3 in 7 patients. Postoperative Gleason scores were (3 + 4 in 2 patients, and (3 + 3 in 6 patients. All these 8 cases were in T1c clinical stage. Early postoperative complications were drain leakage (n = 1, atelectasis (n = 1, wound infection (n = 1 and fever (n = 1. There was no positive surgical margin. The serum level of PSA was less than 0.2 ng/ml and no other complications happened during the 4 to 12 months follow-up period. Postoperative continence and cosmetic results were excellent. Conclusions: It is relatively easy for urologists who are skilled in traditional laparoscopic and robotic surgeries to master SPORP. However long-term outcomes of this surgery need further investigations.

  16. Robotic Assisted Radical Cystoprostatectomy and Intracorporeal Ileal Conduit Urinary Diversion for a Kidney Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Peter A. Caputo

    Full Text Available ABSTRACT Introduction and Objectives: Robotic assisted radical cystectomy (RARC is an alternative to open radical cystectomy. As experience is gained with the RARC approach the technique is being applied to more complex surgical cases. We describe here our technique for RARC with intracorporeal ileal conduit urinary diversion for a renal transplant recipient. Materials and Methods: The patient is a 60-year old man with high-grade muscle invasive bladder cancer. He has a history of renal failure due to polycystic kidney disease and received a deceased donor renal transplant in 2008. His hospital course at time of transplant was complicated by low-level BK virus viremia. Interestingly his trans-urethral bladder tumor resection specimen at time of bladder cancer diagnosis stained positive for SV40. His native kidneys were anuric so bilateral laparoscopic nephrectomy was performed in a staged fashion 2 weeks prior to RARC. Our surgical technique utilizes 6 trocars, of note a 12-mm assistant trocar is placed 1 cm superior to the pubic symphysis, and this trocar is solely used to pass a laparoscopic stapler to facilitate the excision of the ileal segment and the stapled enteric anastomosis. Surgical steps include: identification of native ureters bilaterally (removed en bloc with the bladder specimen; identification of the transplanted ureter at the right bladder dome; posterior bladder and prostate dissection along Denonvilliers’ fascia; development of the space of Retzius; ligation and transection of the bladder and prostate vascular bundles; apical prostate dissection and transection of urethra; left pelvic lymphadenectomy; ilium resection for creation of the ileal conduit; stapled enteric anastomosis; ureteroileal anastomosis; maturation of the ileal conduit stoma. Results: The surgery had no intraoperative complications. Operative time was 443 minutes (7.4 hours. Estimated blood loss was 250 cc. Length of hospital stay was 5 days. The patient

  17. Robot-assisted laparoscopic radical prostatectomy with early retrograde release of the neurovascular bundle and endopelvic fascia sparing

    Directory of Open Access Journals (Sweden)

    George Augusto Monteiro Lins de Albuquerque

    Full Text Available ABSTRACT Introduction Robotic-assisted radical prostatectomy (RAP is the dominant minimally invasive surgical treatment for patients with localized prostate cancer. The introduction of robotic assistance has the potential to improve surgical outcomes and reduce the steep learning curve associated with conventional laparoscopic radical prostatectomy. The purpose of this video is to demonstrate the early retrograde release of the neurovascular bundle without open the endopelvic fascia during RAP. Materials and Methods A 51-year old male, presenting histological diagnosis of prostate adenocarcinoma, Gleason 6 (3+3, in 4 cores of 12, with an initial PSA=3.41ng/dl and the digital rectal examination demonstrating a prostate with hardened nodule in the right lobe of the prostate base (clinical stage T2a. Surgical treatment with the robot-assisted technique was offered as initial therapeutic option and the critical technical point was the early retrograde release of the neurovascular bundle with endopelvic fascia preservation, during radical prostatectomy. Results The operative time was of 89 minutes, blood loss was 100ml. No drain was left in the peritoneal cavity. The patient was discharged within 24 hours. There were no intraoperative or immediate postoperative complications. The pathological evaluation revealed prostate adenocarcinoma, Gleason 6, with free surgical margins and seminal vesicles free of neoplastic involvement (pathologic stage T2a. At 3-month-follow-up, the patient lies with undetectable PSA, continent and potent. Conclusion This is a feasible technique combining the benefits of retrograde release of the neurovascular bundle, the preservation of the pubo-prostatic collar and the preservation of the antero-lateral cavernous nerves.

  18. Learning curve of robot-assisted laparoscopic radical prostatectomy for a single experienced surgeon: comparison with simultaneous laparoscopic radical prostatectomy.

    Science.gov (United States)

    Ku, Ja Yoon; Ha, Hong Koo

    2015-04-01

    Despite the large number of analytical reports regarding the learning curve in the transition from open to robot-assisted radical prostatectomy (RARP), few comparative results with laparoscopic radical prostatectomy (LRP) have been reported. Thus, we evaluated operative and postoperative outcomes in RARP versus 100 simultaneously performed LRPs. A single surgeon had performed more than 1,000 laparoscopic operations, including 415 cases of radical nephrectomy, 85 radical cystectomies, 369 radical prostatectomies, and treatment of 212 other urological tumors, since 2009. We evaluated operative (operation time, intraoperative transfusion, complications, hospital stay, margin status, pathological stage, Gleason score) and postoperative (continence and erectile function) parameters in initial cases of RARP without tutoring compared with 100 recently performed LRPs. Mean operation time and length of hospital stay for RARP and LRP were 145.5±43.6 minutes and 118.1±39.1 minutes, and 6.4±0.9 days and 6.6±1.1 days, respectively (p=0.003 and p=0.721). After 17 cases, the mean operation time for RARP was similar to LRP (less than 2 hours). Positive surgical margins in localized cancer were seen in 11.1% and 8.9% of cases in RARP and LRP, respectively (p=0.733). At postoperative 3 months, sexual intercourse was reported in 14.0% and 12.0%, and pad-free continence in 96.0% and 81.0% in patients with RARP and LRP, respectively (p=0.796 and p=0.012). Previous large-volume experience of LRPs may shorten the learning curve for RARP in terms of oncological outcome. Additionally, previous experience with laparoscopy may improve the functional outcomes of RARP.

  19. Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey

    OpenAIRE

    塚本, 泰司; 田中, 滋

    2015-01-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of ho...

  20. Perioperative and mid-term oncologic outcomes of robotic assisted radical cystectomy with totally intracorporeal neobladder: Results of a propensity score matched comparison with open cohort from a single-centre series.

    Science.gov (United States)

    Simone, Giuseppe; Tuderti, Gabriele; Misuraca, Leonardo; Anceschi, Umberto; Ferriero, Mariaconsiglia; Minisola, Francesco; Guaglianone, Salvatore; Gallucci, Michele

    2018-04-17

    In this study, we compared perioperative and oncologic outcomes of patients treated with either open or robot-assisted radical cystectomy and intracorporeal neobladder at a tertiary care center. The institutional prospective bladder cancer database was queried for "cystectomy with curative intent" and "neobladder". All patients underwent robot-assisted radical cystectomy and intracorporeal neobladder or open radical cystectomy and orthotopic neobladder for high-grade non-muscle invasive bladder cancer or muscle invasive bladder cancer with a follow-up length ≥2 years were included. A 1:1 propensity score matching analysis was used. Kaplan-Meier method was performed to compare oncologic outcomes of selected cohorts. Survival rates were computed at 1,2,3 and 4 years after surgery and the log rank test was applied to assess statistical significance between the matched groups. Overall, 363 patients (299 open and 64 robotic) were included. Open radical cystectomy patients were more frequently male (p = 0.08), with higher pT stages (p = 0.003), lower incidence of urothelial histologies (p = 0.05) and lesser adoption of neoadjuvant chemotherapy (open radical cystectomy cases (all p ≥ 0.22). Open cohort showed a higher rate of perioperative overall complications (91.3% vs 42.2%, p 0.001). At Kaplan-Meier analysis robotic and open cohorts displayed comparable disease-free survival (log-rank p = 0.746), cancer-specific survival (p = 0.753) and overall-survival rates (p = 0.909). Robot-assisted radical cystectomy and intracorporeal neobladder provides comparable oncologic outcomes of open radical cystectomy and orthotopic neobladder at intermediate term survival analysis. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  1. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    Science.gov (United States)

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  2. Optic nerve sheath diameter remains constant during robot assisted laparoscopic radical prostatectomy.

    Directory of Open Access Journals (Sweden)

    Philip Verdonck

    Full Text Available During robot assisted laparoscopic radical prostatectomy (RALRP, a CO2 pneumoperitoneum (CO2PP is applied and the patient is placed in a head-down position. Intracranial pressure (ICP is expected to acutely increase under these conditions. A non-invasive method, the optic nerve sheath diameter (ONSD measurement, may warn us that the mechanism of protective cerebrospinal fluid (CSF shifts becomes exhausted.After obtaining IRB approval and written informed consent, ONSD was measured by ocular ultrasound in 20 ASA I-II patients at various stages of the RALRP procedure: baseline awake, after induction, after applying the CO2PP, during head-down position, after resuming the supine position, in the postoperative anaesthesia care unit, and on day one postoperatively. Cerebral perfusion pressure (CPP was calculated as the mean arterial (MAP minus central venous pressure (CVP.The ONSD did not change during head-down position, although the CVP increased from 4.2(2.5 mm Hg to 27.6(3.8 mm Hg. The CPP was decreased 70 min after assuming the head-down position until 15 min after resuming the supine position, but remained above 60 mm Hg at all times.Even though ICP has been documented to increase during CO2PP and head-down positioning, we did not find any changes in ONSD during head-down position. These results indicate that intracranial blood volume does not increase up to a point that CSF migration as a compensation mechanism becomes exhausted, suggesting any increases in ICP are likely to be small.

  3. Pathological confirmation of nerve-sparing types performed during robot-assisted radical prostatectomy (RARP).

    Science.gov (United States)

    Ko, Woo Jin; Hruby, Gregory W; Turk, Andrew T; Landman, Jaime; Badani, Ketan K

    2013-03-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Incremental nerve-sparing techniques (NSTs) improve postoperative erectile function after robot-assisted radical prostatectomy (RARP). However, there are no studies to date that histologically confirm the surgeon intended NST. Thus, in the present study, we histologically confirmed that the surgeon performed the nerve preservation as his intended NSTs during RARP. Also, we found that there was more variability in fascia width outcome on the left side compared with the right. Therefore, when performing nerve preservation on the surgeon's non-dominant side, we need to pay more close attention. To confirm that the surgeon achieved true intended histological nerve sparing during robot-assisted radical prostatectomy (RARP) by studying RP specimens. To aid the novice robotic surgeon to develop the skills of RARP. Between June 2008 and May 2009, 122 consecutive patients underwent RARP by a single surgeon (K.K.B.). The degree of nerve sparing (wide resection [WR], interfascial nerve sparing [ITE-NS], intrafascial nerve sparing [ITR-NS]) on both sides was recorded. The posterior sectors of RP specimens from distal, mid, and proximal parts were evaluated. Fascia width (FW) of each position in RP specimens were compared across nerve-sparing types (NSTs). FW was recorded at 15 ° intervals (3-9 o'clock position), measured as the distance between the outermost prostate gland and surgical margin. The slides were reviewed by an experienced uropathologist who was 'blinded' to the NST. In all, 93 men were included. The overall mean (sd) FW was the greatest in the order of WR, ITE-NS, and ITR-NS, at 2.42 (1.62), 1.71 (1.40) and 1.16 (1.08) mm, respectively (P ITE-NS, bilateral ITE-NS, ITE-NS/WR, and bilateral WR, respectively. To further validate and confirm these preliminary findings, additional studies involving multicentre cohorts would be required. The surgeon intended dissection and FW correlate, with ITR

  4. Radical-lanthanide ferromagnetic interaction in a T bIII bis-phthalocyaninato complex

    Science.gov (United States)

    Komijani, Dorsa; Ghirri, Alberto; Bonizzoni, Claudio; Klyatskaya, Svetlana; Moreno-Pineda, Eufemio; Ruben, Mario; Soncini, Alessandro; Affronte, Marco; Hill, Stephen

    2018-02-01

    Recent studies have highlighted the importance of organic ligands in the field of molecular spintronics, via which delocalized electron-spin density can mediate magnetic coupling to otherwise localized 4 f moments of lanthanide ions, which show tremendous potential for single-molecule device applications. To this end, high-field/high-frequency electron paramagnetic resonance (EPR) spectroscopy is employed to study a neutral terbium bis-phthalocyaninato metalorganic complex, [TbPc2 ] 0, with the aim of understanding the magnetic interaction between the Ising-like moment of the lanthanide ion and the unpaired spin density on the coordinating organic radical ligand. The measurements were performed on a previously unknown [TbPc2 ] 0 structural phase crystallizing in the Pnma space group. EPR measurements on powder samples of [TbPc2 ] 0 reveal an anisotropic spectrum, which is attributed to the spin-1/2 radical coupled weakly to the EPR-silent T bIII ion. Extensive double-axis rotation studies on a single crystal reveal two independent spin-1/2 signals with differently oriented (albeit identical) uniaxial g -tensors, in complete agreement with x-ray structural studies that indicate two molecular orientations within the unit cell. The easy-axis nature of the radical EPR spectra thus reflects the coupling to the Ising-like T bIII moment. This is corroborated by studies of the isostructural [YPc2 ] 0 analog (where Y is nonmagnetic yttrium), which gives a completely isotropic radical EPR signal. The experimental results for the terbium complex are well explained on the basis of an effective model that introduces a weak ferromagnetic Heisenberg coupling between an isotropic spin-1/2 and an anisotropic spin-orbital moment, J =6 , that mimics the known, strong easy-axis Tb ⋯P c2 crystal-field interaction.

  5. [Analysis of prognostic factors after radical resection in 628 patients with stage II or III colon cancer].

    Science.gov (United States)

    Qin, Qiong; Yang, Lin; Zhou, Ai-ping; Sun, Yong-kun; Song, Yan; DU, Feng; Wang, Jin-wan

    2013-03-01

    To analyze the clinicopathologic factors related to recurrence and metastasis of stage II or III colon cancer after radical resection. The clinical and pathological data of 628 patients with stage II or III colon cancer after radical resection from Jan. 2005 to Dec. 2008 in our hospital were retrospectively reviewed and analyzed. The overall recurrence and metastasis rate was 28.5% (179/628). The 5-year disease-free survival (DFS) rate was 70.3% and 5-year overall survival (OS) rate was 78.5%. Univariate analysis showed that age, smoking intensity, depth of tumor invasion, lymph node metastasis, TNM stage, gross classification, histological differentiation, blood vessel tumor embolus, tumor gross pathology, multiple primary tumors, preoperative and postoperative serum concentration of CEA and CA19-9, and the regimen of adjuvant chemotherapy were correlated to recurrence and metastasis of colon cancer after radical resection. Multivariate analysis showed that regional lymph node metastasis, TNM stage, the regimen of postoperative adjuvant chemotherapy, and preoperative serum concentration of CEA and CA19-9 were independent factors affecting the prognosis of colon cancer patients. Regional lymph node metastasis, TNM stage, elevated preoperative serum concentration of CEA and CA19-9, the regimen of postoperative adjuvant chemotherapy with single fluorouracil type drug are independent risk factors of recurrence and metastasis in patients with stage II-III colon cancer after radical resection.

  6. Consumerism and its impact on robotic-assisted radical prostatectomy.

    Science.gov (United States)

    Alkhateeb, Sultan; Lawrentschuk, Nathan

    2011-12-01

    • Many experts consider that media coverage, marketing and/or direct-to-consumer advertising, particularly Internet-based forms, are fundamental to the widespread adoption of robotic-assisted prostatectomy (RARP). However, this has not been explored previously. • The primary objective of the present study was to delineate the role of media coverage and marketing of RARP on the Internet, whereas the secondary goal focused on website quality with respect to the presentation of prostatectomy. • Website content was evaluated for direct-to-consumer advertising after the retrieval of the first 50 websites using Google and Yahoo for each of the terms: 'robotic prostatectomy, laparoscopic prostatectomy (LP) and open radical prostatectomy (ORP)'. • A linear regression analysis was performed for the annual number of Internet news hits over the last decade for each procedure. Website quality assessment was performed using WHO Honesty on the Internet (HON) code principles. • Of the retrieved sites, the proportion containing direct-to-consumer advertising for RARP vs LP vs ORP using Google was 64% vs 14% vs 0%, respectively (P 0.05). • Media coverage and marketing of RARP on the Internet is more widespread compared to LP and ORP. • Disturbingly, the quality of websites using any technique for prostatectomy was of poor quality when using principles of honest information presenting and such findings need to be discussed with respect to obtaining informed consent from patients. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  7. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  8. An unexpected resident in the ileum detected during robot-assisted laparoscopic radical cystoprostatectomy and intracorporeal Studer pouch formation: Taenia saginata parasite.

    Science.gov (United States)

    Canda, Abdullah Erdem; Asil, Erem; Balbay, Mevlana Derya

    2011-02-01

    A case of moving ileal Taenia saginata parasites is presented with demonstrative images. We came across the parasites surprisingly while performing robot-assisted laparoscopic radical cystoprostatectomy with intracorporeal Studer pouch urinary diversion. We recommend stool sample evaluation in the preoperative period for possible presence of intestinal parasitic diseases, particularly in patients with bladder cancer who are admitted from areas with an increased incidence of intestinal parasitic diseases, before opening the bowel segments during surgery to perform radical cystectomy and urinary diversion.

  9. Dose-Escalated Robotic SBRT for Stage I-II Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Robert eMeier

    2015-04-01

    Full Text Available Abstract: Stereotactic body radiotherapy (SBRT is the precise external delivery of very high-dose radiotherapy to targets in the body, with treatment completed in one to five fractions. SBRT should be an ideal approach for organ-confined prostate cancer because (I dose escalation should yield improved rates of cancer control; (II the unique radiobiology of prostate cancer favors hypofractionation and (III the conformal nature of SBRT minimizes high-dose radiation delivery to immediately adjacent organs, potentially reducing complications. This approach is also more convenient for patients, and is cheaper than intensity modulated radiotherapy (IMRT. Several external beam platforms are capable of delivering SBRT for early-stage prostate cancer, although most of the mature reported series have employed a robotic non-coplanar platform (i.e., CyberKnife. Several large studies report 5-year biochemical relapse rates which compare favorably to IMRT. Rates of late GU toxicity are similar to those seen with IMRT, and rates of late rectal toxicity may be less than with IMRT and low dose rate (LDR brachytherapy. Patient-reported quality of life (QOL outcomes appear similar to IMRT in the urinary domain. Bowel QOL may be less adversely affected by SBRT than with other radiation modalities. After five years of follow-up, SBRT delivered on a robotic platform is yielding outcomes at least as favorable as IMRT, and may be considered appropriate therapy for stage I-II prostate cancer.

  10. Oncological outcomes of high-risk prostate cancer patients between robot-assisted laparoscopic radical prostatectomy and laparoscopic radical prostatectomy in Taiwan

    Directory of Open Access Journals (Sweden)

    Chieh-Chun Liao

    2018-01-01

    Full Text Available Objective: To compare pathological and oncological outcomes between robotic-assisted laparoscopic radical prostatectomy (RaLRP and laparoscopic radical prostatectomy (LRP among high-risk prostate cancer patient in a tertiary center in Taiwan. Materials and methods: From November 2003 to October 2013, 129 high-risk prostate cancer patients receiving minimally-invasive radical prostatectomy were included. The Kaplan–Meier analysis was used for measuring biochemical recurrence-free survival (BFS. Multivariate logistic regression models and Cox proportional hazards regression models were used to determine predictors of positive surgical margin and BFS. Results: Among the 129 high-risk prostate cancer patients included, 80 (62% patients received LRP and 49 (38% patients received RaLRP. There was no significant difference of positive surgical margin and biochemical recurrence rate between RaLRP and LRP group (P = 0.802 and 0.292. Higher pathological T stage predicted an increased likelihood of positive margins (OR = 3.44, 95% CI [1.45, 8.18], P = 0.005. Higher initial PSA level (HR = 2.88, 95% CI [1.04, 7.94], P = 0.041 and positive surgical margin (HR = 2.55, 95% CI [1.20, 5.44], P = 0.015 were poor prognostic factors for BFS. Conclusion: RaLRP can be considered among high-risk prostate cancer in Asian people with comparable oncological outcomes to LRP. Higher pathological T stage was associated with increased likelihood of positive margins, patients with higher iPSA level and positive surgical margin had worsen biochemical recurrence-free survival.

  11. Modular Training for Robot-Assisted Radical Prostatectomy: Where to Begin?

    Science.gov (United States)

    Lovegrove, Catherine; Ahmed, Kamran; Novara, Giacomo; Guru, Khurshid; Mottrie, Alex; Challacombe, Ben; der Poel, Henk Van; Peabody, James; Dasgupta, Prokar

    Effective training is paramount for patient safety. Modular training entails advancing through surgical steps of increasing difficulty. This study aimed to construct a modular training pathway for use in robot-assisted radical prostatectomy (RARP). It aims to identify the sequence of procedural steps that are learnt before surgeons are able to perform a full procedure without an intervention from mentor. This is a multi-institutional, prospective, observational, longitudinal study. We used a validated training tool (RARP Score). Data regarding surgeons' stage of training and progress were collected for analysis. A modular training pathway was constructed with consensus on the level of difficulty and evaluation of individual steps. We identified and recorded the sequence of steps performed by fellows during their learning curves. We included 15 urology fellows from UK, Europe, and Australia. A total of 15 surgeons were assessed by mentors in 425 RARP cases over 8 months (range: 7-79) across 15 international centers. There were substantial differences in the sequence of RARP steps according to the chronology of the procedure, difficulty level, and the order in which surgeons actually learned steps. Steps were not attempted in chronological order. The greater the difficulty, the later the cohort first undertook the step (p = 0.021). The cohort undertook steps of difficulty level I at median case number 1. Steps of difficulty levels II, III, and IV showed more variation in median case number of the first attempt. We recommend that, in the operating theater, steps be learned in order of increasing difficulty. A new modular training route has been designed. This incorporates the steps of RARP with the following order of priority: difficulty level > median case number of first attempt > most frequently undertaken in surgical training. An evidence-based modular training pathway has been developed that facilitates a safe introduction to RARP for novice surgeons. Copyright

  12. Experimental evidence for cobalt(III)-carbene radicals: key intermediates in cobalt(II)-based metalloradical cyclopropanation

    NARCIS (Netherlands)

    Lu, H.; Dzik, W.I.; Xu, X.; Wojtas, L.; de Bruin, B.; Zhang, X.P.

    2011-01-01

    New and conclusive evidence has been obtained for the existence of cobalt(III)-carbene radicals that have been previously proposed as the key intermediates in the underlying mechanism of metalloradical cyclopropanation by cobalt(II) complexes of porphyrins. In the absence of olefin substrates,

  13. Formation of environmentally persistent free radical (EPFR) in iron(III) cation-exchanged smectite clay.

    Science.gov (United States)

    Nwosu, Ugwumsinachi G; Roy, Amitava; dela Cruz, Albert Leo N; Dellinger, Barry; Cook, Robert

    2016-01-01

    Environmentally persistent free radicals (EPFRs) have been found at a number of Superfund sites, with EPFRs being formed via a proposed redox process at ambient environmental conditions. The possibility of such a redox process taking place at ambient environmental conditions is studied utilizing a surrogate soil system of phenol and iron(III)-exchanged calcium montmorillonite clay, Fe(III)CaM. Sorption of phenol by the Fe(III)CaM is demonstrated by Fourier-transformed infra-red (FT-IR) spectroscopy, as evidenced by the peaks between 1345 cm(-1) and 1595 cm(-1), and at lower frequencies between 694 cm(-1) and 806 cm(-1), as well as X-ray diffraction (XRD) spectroscopy, as shown by an increase in interlayer spacing within Fe(III)CaM. The formation and characterization of the EPFRs is determined by electron paramagnetic resonance (EPR) spectroscopy, showing phenoxyl-type radical with a g-factor of 2.0034 and ΔHP-P of 6.1 G at an average concentration of 7.5 × 10(17) spins per g. EPFRs lifetime data are indicative of oxygen and water molecules being responsible for EPFR decay. The change in the oxidation state of the iron redox center is studied by X-ray absorption near-edge structure (XANES) spectroscopy, showing that 23% of the Fe(III) is reduced to Fe(II). X-ray photoemission spectroscopy (XPS) results confirm the XANES results. These findings, when combined with the EPFR concentration data, demonstrate that the stoichiometry of the EPFR formation under the conditions of this study is 1.5 × 10(-2) spins per Fe(II) atom.

  14. When Partial Nephrectomy is Unsuccessful: Understanding the Reasons for Conversion from Robotic Partial to Radical Nephrectomy at a Tertiary Referral Center.

    Science.gov (United States)

    Kara, Önder; Maurice, Matthew J; Mouracade, Pascal; Malkoç, Ercan; Dagenais, Julien; Nelson, Ryan J; Chavali, Jaya Sai S; Stein, Robert J; Fergany, Amr; Kaouk, Jihad H

    2017-07-01

    We sought to identify the preoperative factors associated with conversion from robotic partial nephrectomy to radical nephrectomy. We report the incidence of this event. Using our institutional review board approved database, we abstracted data on 1,023 robotic partial nephrectomies performed at our center between 2010 and 2015. Standard and converted cases were compared in terms of patients and tumor characteristics, and perioperative, functional and oncologic outcomes. Logistic regression analysis was done to identify predictors of radical conversion. The overall conversion rate was 3.1% (32 of 1,023 cases). The most common reasons for conversion were tumor involvement of hilar structures (8 cases or 25%), failure to achieve negative margins on frozen section (7 or 21.8%), suspicion of advanced disease (5 or 15.6%) and failure to progress (5 or 15.6%). Patients requiring conversion were older and had a higher Charlson score (both p partial nephrectomy cases had similar short-term oncologic outcomes but better renal functional preservation (p partial nephrectomy conversion to radical nephrectomy was 3.1%, including 2.2% of preoperatively anticipated nephrectomy cases. Increasing tumor size and complexity, and poor preoperative renal function are the main predictors of conversion. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Impact of tamsulosin on urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy: a prospective randomized controlled trial.

    Science.gov (United States)

    Jeong, In Gab; You, Dalsan; Yoon, Jong Hyun; Hong, Sungwoo; Lim, Ju Hyun; Hong, Jun Hyuk; Choo, Myung-Soo; Ahn, Hanjong; Kim, Choung-Soo

    2014-02-01

    To examine the impact of tamsulosin on the rate of acute urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy. A total of 236 patients who underwent robot-assisted laparoscopic radical prostatectomy for prostate cancer carried out by a single surgeon were enrolled in this randomized study. Patients were randomly divided into two groups: treatment with tamsulosin (0.4 mg) from 1 day before to 14 days after surgery (tamsulosin group), or no tamsulosin treatment (control group). The urethral catheter was removed on the fifth postoperative day. The primary end-point was the acute urinary retention rate. Changes in each domain of the International Continence Society male short-form questionnaire and uroflowmetry parameters were secondary end-points. The primary end-point was assessed in 218 patients (92.4%; n = 109 in each group). It was not assessed in 18 patients because of cystographic leak from the vesicourethral anastomosis. The acute urinary retention rate was lower in the tamsulosin group (7.3%) than in the control group (17.4%, P = 0.018). Multivariate logistic regression analysis identified tamsulosin treatment and the operative experience of the surgeon as independent risk factors for acute urinary retention. Tamsulosin-treated patients had a 0.30-fold lower risk of developing acute urinary retention compared with control patients (95% confidence interval 0.12-0.76; P = 0.011). None of the International Continence Society male questionnaire domain scores showed significant changes between the groups. Perioperative treatment with tamsulosin in patients undergoing robot-assisted laparoscopic radical prostatectomy reduces the rate of acute urinary retention after early catheter removal, without aggravating urinary incontinence. © 2013 The Japanese Urological Association.

  16. Pentachlorophenol radical cations generated on Fe(III)-montmorillonite initiate octachlorodibenzo-p-dioxin formation in clays: DFT and FTIR studies

    Science.gov (United States)

    Gu, Cheng; Liu, Cun; Johnston, Cliff T.; Teppen, Brian J.; Li, Hui; Boyd, Stephen A.

    2011-01-01

    Octachlorodibenzodioxin (OCDD) forms spontaneously from pentachlorophenol (PCP) on the surfaces of Fe(III)-saturated smectite clay (1). Here, we used in situ FTIR methods and quantum mechanical calculations to determine the mechanism by which this reaction is initiated. As the clay was dehydrated, vibrational spectra showed new peaks that grew and then reversibly disappeared as the clay rehydrated. First principle DFT calculations of hydrated Fe-PCP clusters reproduced these transient FTIR peaks when inner-sphere complexation and concomitant electron transfer produced Fe(II) and PCP radical cations. Thus, our experimental (FTIR) and theoretical (quantum mechanical) results mutually support the hypothesis that OCDD formation on Fe-smectite surfaces is initiated by the reversible formation of metastable PCP radical cations via single electron transfer from PCP to Fe(III). The negatively charged clay surface apparently selects for this reaction mechanism by stabilizing PCP radical cations. PMID:21254769

  17. Early biochemical recurrence, urinary continence and potency outcomes following robot-assisted radical prostatectomy

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Thomsen, Frederik Birkebæk; Hvarness, Helle

    2014-01-01

    OBJECTIVE: The aim of this study was to describe recovery of urinary continence and potency and report oncological and functional outcomes using the survival, continence and potency (SCP) system for patients undergoing robot-assisted radical prostatectomy (RARP). MATERIAL AND METHODS: From 2009...... with preoperative ESI, 77.6% (67.9-86.1) and 34.4% (24.1-47.5) maintained ESI 12 months postoperatively after bilateral and unilateral nerve-sparing surgery (NS), respectively. NS (p .... Using the SCP system and defining potency as ESI, functional and oncological success 12 months after surgery was achieved in 69 out of 135 (51.1%) preoperative continent and potent patients who underwent unilateral or bilateral NS, and did not require adjuvant treatment; when defining potency as IIEF...

  18. Natural montmorillonite induced photooxidation of As(III) in aqueous suspensions: Roles and sources of hydroxyl and hydroperoxyl/superoxide radicals

    International Nuclear Information System (INIS)

    Wang, Yajie; Xu, Jing; Li, Jinjun; Wu, Feng

    2013-01-01

    Highlights: • Natural montmorillonite contributes to photochemical oxidation of arsenite. • Ferrous ions significantly affect photochemical behavior of montmorillonite. • HO· and HO 2 ·/O 2 − · play different roles in this process. -- Abstract: Photooxidation of arsenite(As(III)) in a suspension of natural montmorillonite under the irradiation of metal halide lamp (λ ≥ 313 nm)has been investigated. The results showed that the natural montmorillonite induced the photooxidation of As(III) by generating hydroxyl radicals (HO·) and hydroperoxyl/superoxide radicals (HO 2 ·/O 2 − ·). HO· which was responsible for the As(III) photooxidation. Approximately 38% of HO· was generated by the photolysis of ferric ions, and the formation of the remaining 62% was strongly dependent on the HO 2 ·/O 2 − ·. The presence of free ironions (Fe 2+ and Fe 3+ ), made significant contributions to the photogeneration of these reactive oxygen species (ROS). The photooxidation of As(III) in natural montmorillonite suspensions was greatly influenced by the pH values. The photooxidation of As(III) by natural montmorillonite followed the Langmuir–Hinshelwood equation. In addition, the photooxidation of As(III) could be enhanced by the addition of humic acid. This work demonstrates that photooxidation may be an important environmental process for the oxidation of As(III) and may be a way to remove As(III) from acidic surface water containing iron-bearing clay minerals

  19. Formation and Stabilization of Environmentally Persistent Free Radicals Induced by the Interaction of Anthracene with Fe(III)-Modified Clays.

    Science.gov (United States)

    Jia, Hanzhong; Nulaji, Gulimire; Gao, Hongwei; Wang, Fu; Zhu, Yunqing; Wang, Chuanyi

    2016-06-21

    Environmentally persistent free radicals (EPFRs) are occasionally detected in Superfund sites but the formation of EPFRs induced by polycyclic aromatic hydrocarbons (PAHs) is not well understood. In the present work, the formation of EPFRs on anthracene-contaminated clay minerals was quantitatively monitored via electron paramagnetic resonance (EPR) spectroscopy, and surface/interface-related environmental influential factors were systematically explored. The obtained results suggest that EPFRs are more readily formed on anthracene-contaminated Fe(III)-montmorillonite than in other tested systems. Depending on the reaction condition, more than one type of organic radicals including anthracene-based radical cations with g-factors of 2.0028-2.0030 and oxygenic carbon-centered radicals featured by g-factors of 2.0032-2.0038 were identified. The formed EPFRs are stabilized by their interaction with interlayer surfaces, and such surface-bound EPFRs exhibit slow decay with 1/e-lifetime of 38.46 days. Transformation pathway and possible mechanism are proposed on the basis of experimental results and quantum mechanical simulations. Overall, the formation of EPFRs involves single-electron-transfer from anthracene to Fe(III) initially, followed by H2O addition on formed aromatic radical cation. Because of their potential exposure in soil and atmosphere, such clay surface-associated EPFRs might induce more serious toxicity than PAHs and exerts significant impacts on human health.

  20. Ca2+ and Mg2+-enhanced reduction of arsenazo III to its anion free radical metabolite and generation of superoxide anion by an outer mitochondrial membrane azoreductase.

    Science.gov (United States)

    Moreno, S N; Mason, R P; Docampo, R

    1984-12-10

    At the concentrations usually employed as a Ca2+ indicator, arsenazo III underwent a one-electron reduction by rat liver mitochondria to produce an azo anion radical as demonstrated by electron-spin resonance spectroscopy. Either NADH or NADPH could serve as a source of reducing equivalents for the production of this free radical by intact rat liver mitochondria. Under aerobic conditions, addition of arsenazo III to rat liver mitochondria produced an increase in electron flow from NAD(P)H to molecular oxygen, generating superoxide anion. NAD(P)H generated from endogenous mitochondrial NAD(P)+ by intramitochondrial reactions could not be used for the NAD(P)H azoreductase reaction unless the mitochondria were solubilized by detergent or anaerobiosis. In addition, NAD(P)H azoreductase activity was higher in the crude outer mitochondrial membrane fraction than in mitoplasts and intact mitochondria. The steady-state concentration of the azo anion radical and the arsenazo III-stimulated cyanide-insensitive oxygen consumption were enhanced by calcium and magnesium, suggesting that, in addition to an enhanced azo anion radical-stabilization by complexation with the metal ions, enhanced reduction of arsenazo III also occurred. Accordingly, addition of cations to crude outer mitochondrial membrane preparations increased arsenazo III-stimulated cyanide-insensitive O2 consumption, H2O2 formation, and NAD(P)H oxidation. Antipyrylazo III was much less effective than arsenazo III in increasing superoxide anion formation by rat liver mitochondria and gave a much weaker electron spin resonance spectrum of an azo anion radical. These results provide direct evidence of an azoreductase activity associated with the outer mitochondrial membrane and of a stimulation of arsenazo III reduction by cations.

  1. Robot-assisted radical prostatectomy: Multiparametric MR imaging-directed intraoperative frozen-section analysis to reduce the rate of positive surgical margins.

    Science.gov (United States)

    Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo

    2015-02-01

    To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides

  2. Manipulating radicals: Using cobalt to steer radical reactions

    OpenAIRE

    Chirilă, A.

    2017-01-01

    This thesis describes research aimed at understanding and exploiting metallo-radical reactivity and explores reactions mediated by square planar, low-spin cobalt(II) complexes. A primary goal was to uncover novel reactivity of discrete cobalt(III)-bound carbene radicals generated upon reaction of the cobalt(II) catalysts with carbene precursors. Another important goal was to replace cobalt(II)-porphyrin catalysts with cheaper and easier to prepare metallo-radical analogues. Therefore the cata...

  3. The Da Vinci Xi and robotic radical prostatectomy-an evolution in learning and technique.

    Science.gov (United States)

    Goonewardene, S S; Cahill, D

    2017-06-01

    The da Vinci Xi robot has been introduced as the successor to the Si platform. The promise of the Xi is to open the door to new surgical procedures. For robotic-assisted radical prostatectomy (RARP)/pelvic surgery, the potential is better vision and longer instruments. How has the Xi impacted on operative and pathological parameters as indicators of surgical performance? This is a comparison of an initial series of 42 RARPs with the Xi system in 2015 with a series using the Si system immediately before Xi uptake in the same calendar year, and an Si series by the same surgeon synchronously as the Xi series using operative time, blood loss, and positive margins as surrogates of surgical performance. Subjectively and objectively, there is a learning curve to Xi uptake in longer operative times but no impact on T2 positive margins which are the most reflective single measure of RARP outcomes. Subjectively, the vision of the Xi is inferior to the Si system, and the integrated diathermy system and automated setup are quirky. All require experience to overcome. There is a learning curve to progress from the Si to Xi da Vinci surgical platforms, but this does not negatively impact the outcome.

  4. Robot-assisted radical prostatectomy has lower biochemical recurrence than laparoscopic radical prostatectomy: Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Seon Heui Lee

    2017-05-01

    Full Text Available Purpose: To assess the effectiveness and safety of robot-assisted radical prostatectomy (RARP versus laparoscopic radical prostatectomy (LRP in the treatment of prostate cancer. Materials and Methods: Existing systematic reviews were updated to investigate the effectiveness and safety of RARP. Electronic databases, including Ovid MEDLINE, Ovid Embase, the Cochrane Library, KoreaMed, Kmbase, and others, were searched through July 2014. The quality of the selected systematic reviews was assessed by using the revised assessment of multiple systematic reviews (R-Amstar and the Cochrane Risk of Bias tool. Meta-analysis was performed by using Revman 5.2 (Cochrane Community and Comprehensive Meta-Analysis 2.0 (CMA; Biostat. Cochrane Q and I2 statistics were used to assess heterogeneity. Results: Two systematic reviews and 16 additional studies were selected from a search performed of existing systematic reviews. These included 2 randomized controlled clinical trials and 28 nonrandomized comparative studies. The risk of complications, such as injury to organs by the Clavien-Dindo classification, was lower with RARP than with LRP (relative risk [RR], 0.44; 95% confidence interval [CI], 1.23–0.85; p=0.01. The risk of urinary incontinence was lower (RR, 0.43; 95% CI, 0.31–0.60; p<0.000001 and the potency rate was significantly higher with RARP than with LRP (RR, 1.38; 95% CI, 1.11–1.70; I2 =78%; p=0.003. Regarding positive surgical margins, no significant difference in risk between the 2 groups was observed; however, the biochemical recurrence rate was lower after RARP than after LRP (RR, 0.59; 95% CI, 0.48–0.73; I2 =21%; p<0.00001. Conclusions: RARP appears to be a safe and effective technique compared with LRP with a lower complication rate, better potency, a higher continence rate, and a decreased rate of biochemical recurrence.

  5. Ferromagnetic interactions in Ru(III)-nitronyl nitroxide radical complex: a potential 2p4d building block for molecular magnets.

    Science.gov (United States)

    Pointillart, Fabrice; Bernot, Kevin; Sorace, Lorenzo; Sessoli, Roberta; Gatteschi, Dante

    2007-07-07

    The reaction between [Ru(salen)(PPh3)Cl] and the 4-pyridyl-substituted nitronyl nitroxide radical (NITpPy) leads to the [Ru(salen)(PPh3)(NITpPy)](ClO4)(H2O)2 complex while the reaction with the azido anion (N3-) leads to the [Ru(salen)(PPh3)(N3)] complex 2 (where salen2- = N,N'-ethan-1,2-diylbis(salicylidenamine) and PPh3 = triphenylphosphine). Both compounds have been characterized by single crystal X-ray diffraction. The two crystal structures are composed by a [Ru(III)(salen)(PPh3)]+ unit where the Ru(III) ion is coordinated to a salen2- ligand and one PPh3 ligand in axial position. In 1 the Ru(III) ion is coordinated to the 4-pyridyl-substituted nitronyl nitroxide radical whereas in 2 the second axial position is occupied by the azido ligand. In both complexes the Ru(III) ions are in the same environment RuO2N3P, in a tetragonally elongated octhaedral geometry. The crystal packing of 1 reveals pi-stacking in pairs. While antiferromagnetic intermolecular interaction (J2 = 5.0 cm(-1)) dominates at low temperatures, ferromagnetic intramolecular interaction (J1 = -9.0 cm(-1)) have been found between the Ru(III) ion and the coordinated NITpPy.

  6. Urologic robotic surgery in Korea: past and present.

    Science.gov (United States)

    Seo, Ill Young

    2015-08-01

    Since 2005 when the da Vinci surgical system was approved as a medical device by the Korean Ministry of Health and Welfare, 51 systems have been installed in 40 institutions as of May 2015. Although robotic surgery is not covered by the national health insurance service in Korea, it has been used in several urologic fields as a less invasive surgery. Since the first robotic-assisted laparoscopic radical prostatectomy in 2005, partial nephrectomy, radical cystectomy, pyeloplasty, and other urologic surgeries have been performed. The following should be considered to extend the indications for robotic surgery: training systems including accreditation, operative outcomes from follow-up results, and cost-effectiveness. In this review, the history and current status of robotic surgeries in Korea are presented.

  7. Pelvic lymph node dissection during robot-assisted radical prostatectomy: efficacy, limitations, and complications-a systematic review of the literature.

    Science.gov (United States)

    Ploussard, Guillaume; Briganti, Alberto; de la Taille, Alexandre; Haese, Alexander; Heidenreich, Axel; Menon, Mani; Sulser, Tullio; Tewari, Ashutosh K; Eastham, James A

    2014-01-01

    Pelvic lymph node dissection (PLND) in prostate cancer is the most effective method for detecting lymph node metastases. However, a decline in the rate of PLND during radical prostatectomy (RP) has been noted. This is likely the result of prostate cancer stage migration in the prostate-specific antigen-screening era, and the introduction of minimally invasive approaches such as robot-assisted radical prostatectomy (RARP). To assess the efficacy, limitations, and complications of PLND during RARP. A review of the literature was performed using the Medline, Scopus, and Web of Science databases with no restriction of language from January 1990 to December 2012. The literature search used the following terms: prostate cancer, radical prostatectomy, robot-assisted, and lymph node dissection. The median value of nodal yield at PLND during RARP ranged from 3 to 24 nodes. As seen in open and laparoscopic RP series, the lymph node positivity rate increased with the extent of dissection during RARP. Overall, PLND-only related complications are rare. The most frequent complication after PLND is symptomatic pelvic lymphocele, with occurrence ranging from 0% to 8% of cases. The rate of PLND-associated grade 3-4 complications ranged from 0% to 5%. PLND is associated with increased operative time. Available data suggest equivalence of PLND between RARP and other surgical approaches in terms of nodal yield, node positivity, and intraoperative and postoperative complications. PLND during RARP can be performed effectively and safely. The overall number of nodes removed, the likelihood of node positivity, and the types and rates of complications of PLND are similar to pure laparoscopic and open retropubic procedures. Copyright © 2013 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  8. Posterior muscolofascial reconstruction incorporated into urethrovescical anastomosis during robot-assisted radical prostatectomy.

    Science.gov (United States)

    Ficarra, Vincenzo; Gan, Melanie; Borghesi, Marco; Zattoni, Fabio; Mottrie, Alexandre

    2012-12-01

    The rationale of posterior musculofascial plate reconstruction during radical prostatectomy is to shorten the time to reach urinary continence recovery and to reduce the risk of bleeding and anastomosis leakage. We describe our original technique incorporating the posterior muscolofascial reconstruction into urethrovesical anastomosis using robot-assisted radical prostatectomy (RARP). For this reconstructive step, we use a 30-cm V-Loc 90 3-0 barbed suture (V-20 tapered needle). Specifically, the free edge of the posterior layer of the Denonvilliers fascia is approximated to the posterior part of the sphincteric apparatus in a running fashion from left to right. The musculature of the urethral wall is incorporated in this first layer of the running suture. This suture is then continued back to the left in a second layer incorporating the anterior layer of the Denonvilliers fascia (or prostatovesical muscle), the bladder neck, and again the urethra, this time also with urethral mucosa. The urethrovesical anastomosis is completed using a second running barbed suture (15-cm V-Loc 90 3-0 barbed suture, V-20 tapered needle). No intraoperative complications were observed during this step of the procedure. Anastomotic leakages were observed only in 2% of cases. Only 12.5% showed urinary incontinence after catheter removal (1-2 pads). At mean follow-up of 9 months, the urinary continence recovery was 95%, and an anastomosis stricture necessitating an endoscopic incision developed in only three (1.5%) patients. Recent systematic reviews of the literature showed only a minimal advantage in favor of posterior musculofascial reconstruction in terms of urinary continence recovery within 1 month after radical prostatectomy. We support the use of this step of RARP because it is simple, reproducible, with a very limited increase in operative time, and with only a slight risk of potential harm to the patient. Moreover, it could improve hemostasis and provide greater support for a

  9. Have Case Loads of Radical Surgery for Prostate Cancer Been Concentrated in Hospitals with Robotic Equipment ?―Analyses with Questionnaire Survey and Diagnostic Procedure Combination (DPC) Data―

    OpenAIRE

    塚本, 泰司; 田中, 滋

    2016-01-01

    We investigated whether installation of robot-assisted surgical equipment in hospitals resulted in concentration of the case loads of radical prostatectomy. We selected 11 areas with populations of around 1 million or more where there were one or more hospitals with robotic equipment and 4 or more without it. In addition, annual changes of case loads for prostatectomy over 4 years from 2010 to 2013 were clearly determined in these areas. The case loads were determined based on the results of ...

  10. Integrating Multi-Purpose Natural Language Understanding, Robot's Memory, and Symbolic Planning for Task Execution in Humanoid Robots

    DEFF Research Database (Denmark)

    Wächter, Mirko; Ovchinnikova, Ekaterina; Wittenbeck, Valerij

    2017-01-01

    We propose an approach for instructing a robot using natural language to solve complex tasks in a dynamic environment. In this study, we elaborate on a framework that allows a humanoid robot to understand natural language, derive symbolic representations of its sensorimotor experience, generate....... The framework is implemented within the robot development environment ArmarX. We evaluate the framework on the humanoid robot ARMAR-III in the context of two experiments: a demonstration of the real execution of a complex task in the kitchen environment on ARMAR-III and an experiment with untrained users...

  11. International Radical Cystectomy Consortium: A way forward

    Directory of Open Access Journals (Sweden)

    Syed Johar Raza

    2014-01-01

    Full Text Available Robot-assisted radical cystectomy (RARC is an emerging operative alternative to open surgery for the management of invasive bladder cancer. Studies from single institutions provide limited data due to the small number of patients. In order to better understand the related outcomes, a world-wide consortium was established in 2006 of patients undergoing RARC, called the International Robotic Cystectomy Consortium (IRCC. Thus far, the IRCC has reported its findings on various areas of operative interest and continues to expand its capacity to include other operative modalities and transform it into the International Radical Cystectomy Consortium. This article summarizes the findings of the IRCC and highlights the future direction of the consortium.

  12. Robotic-assisted versus open radical cystectomy in bladder cancer: A meta-analysis of four randomized controlled trails.

    Science.gov (United States)

    Tang, Jin-Qiu; Zhao, Zhihong; Liang, Yiwen; Liao, Guixiang

    2018-02-01

    Robot-assisted radical cystectomy (RARC) is increasing annually for treatment of bladder cancer. The objective of this meta-analysis was to compare the safety and efficacy of RARC and open radical cystectomy (ORC) for bladder cancer. Our meta-analysis searches were conducted using PubMed, Web of Science, and Cochrane Library databases to identify randomized controlled trials (RCT) assessing the two techniques. Four RCT studies were identified, including 239 cases. Our studies indicated that RARC was associated with longer operative time (WMD: 69.69, 95% CI:17.25 to122.12; P= 0.009), lower estimated blood loss (WMD: -299.83, 95% CI:-414.66to -184.99; P<0.00001). The two groups had no significant difference in overall perioperative complications, length of hospital stay, lymph node yield and positive surgical margins. RARC is mini-invasive alternative to ORC for bladder cancer. The advantage of RARC was reduced estimated blood loss. More studies are needed to compare the two techniques. Copyright © 2017 John Wiley & Sons, Ltd.

  13. ROBOT-ASSISTED RADICAL PROSTATECTOMY: ANALYSIS OF THE FIRST 80 CASES

    Directory of Open Access Journals (Sweden)

    D. Yu. Pushkar

    2010-01-01

    Full Text Available Background. As a common disease, prostate cancer (PC has taken now first place among all malignancies in many countries of the world.The authors have analyzed the results of their series of robot-assisted radical laparoscopic prostatectomy (RALP in patients with PC. They also present a number of surgical techniques that may be useful for novice surgeons. Materials and methods. In November 2008 to November 2009, the Department of Urology, Moscow State University of Medicine and Dentistry, performed 80 RALPs using the da Vinci S surgical robotic system. The patients’ mean age was 63.7 (49–71 years; the mean blood level of total prostate-specific antigen was 6.1 (2.1–20.84 ng/ml; the mean prostate volume was 44 (18–94 cm3, as evidenced by transrectal ultrasound study. The authors analyzed the following indicators: operating time, degree of blood loss, conversion of surgical intervention,degrees of intra- and postoperative complications, and oncological and functional results. Results. In our series, RALP was performed without preserving neurovascular bundles or by using a nerve-sparing procedure in 66 (82.5% and 14 (17.5%, respectively; 22 (27.5% patients underwent lymphadenectomy. The average length of hospital stay was 7 (4–21 days; the mean time of urethral catheter removal was 10 (6–21 days postoperatively. The mean time of surgical intervention was 174 (121–276 min. Mean blood loss was 248 (35–1950 ml. Postmortem study revealed a positive surgical margin in 19 (24% cases and tumor invasion into the seminal vesicles in 5 (6% patients. Stages pT2 and pT3 were found in 56 (70% and 24 (30%, respectively; total Gleason scores were 6 (3+3, 7 (3+4, 7 (4+3, 8 (4+4 in 38 (47.5%, 35 (43.75%, 5 (6.25%, and 2 (2.5% patients, respectively. Among 34 patients examined 3 months after RALP, 28 (82.4% patients completely retained urine; 5 (14.7% applied not more than a pad a day. In patients with preserved erectile function, the

  14. Formation of long-lived radicals on proteins by radical transfer from heme enzymes--a common process?

    DEFF Research Database (Denmark)

    Ostdal, H; Andersen, H J; Davies, Michael Jonathan

    1999-01-01

    concentrations were observed after limited digestion, although this effect was less marked with the HRP/H2O2/BSA system than with Fe(III)Mb/H2O2/BSA, consistent with different modes of radical transfer. More extensive digestion of BSA decreased the radical concentration to levels below those detected with native...... investigated using horseradish peroxidase (HRP)/H2O2, in the presence and absence of added tyrosine. Incubation of HRP with H2O2 and bovine or human serum albumins, in the presence and absence of tyrosine, gave long-lived albumin-derived radicals as detected by EPR spectroscopy. Evidence has been obtained...... for these albumin radicals being located on buried tyrosine residues on the basis of blocking experiments. The effect of protein conformation on radical transfer has been investigated using partial proteolytic digestion prior to protein oxidation. With HRP/H2O2/BSA and Fe(III)Mb/H2O2/BSA increased radical...

  15. 9,10-phenanthrenesemiquinone radical complexes of ruthenium(III), osmium(III) and rhodium(III) and redox series.

    Science.gov (United States)

    Biswas, Manas Kumar; Patra, Sarat Chandra; Maity, Amarendra Nath; Ke, Shyue-Chu; Weyhermüller, Thomas; Ghosh, Prasanta

    2013-05-14

    Reactions of 9,10-phenanthrenequinone (PQ) in toluene with [M(II)(PPh3)3X2] at 298 K afford green complexes, trans-[M(PQ)(PPh3)2X2] (M = Ru, X = Cl, 1; M = Os, X = Br, 2) in moderate yields. Reaction of anhydrous RhCl3 with PQ and PPh3 in boiling ethanol affords the dark brown paramagnetic complex, cis-[Rh(PQ)(PPh3)2Cl2] (3) in good yields. Diffusion of iodine solution in n-hexane to the trans-[Os(PQ) (PPh3)2(CO)(Br)] solution in CH2Cl2 generates the crystals of trans-[Os(PQ)(PPh3)2(CO)(Br)](+)I3(-), (4(+))I3(-)), in lower yields. Single crystal X-ray structure determinations of 1·2toluene, 2·CH2Cl2 and 4(+)I3(-), UV-vis/NIR absorption spectra, EPR spectra of 3, electrochemical activities and DFT calculations on 1, 2, trans-[Ru(PQ)(PMe3)2Cl2] (1Me), trans-[Os(PQ)(PMe3)2Br2] (2Me), cis-[Rh(PQ)(PMe3)2Cl2] (3Me) and their oxidized and reduced analogues including trans-[Os(PQ)(PMe3)2(CO)(Br)](+) (4Me(+)) substantiated that 1-3 are the 9,10-phenanthrenesemiquinone radical (PQ(˙-)) complexes of ruthenium(III), osmium(III) and rhodium(III) and are defined as trans/cis-[M(III)(PQ(˙-))(PPh3)2X2] with a minor contribution of the resonance form trans/cis-[M(II)(PQ)(PPh3)2X2]. Two comparatively longer C-O (1.286(4) Å) and the shorter C-C lengths (1.415(7) Å) of the OO-chelate of 1·2toluene and 2·CH2Cl2 and the isotropic fluid solution EPR signal at g = 1.999 of 3 are consistent with the existence of the reduced PQ(˙-) ligand in 1-3 complexes. Anisotropic EPR spectra of the frozen glasses (g11 = g22 = 2.0046 and g33 = 1.9874) and solids (g11 = g22 = 2.005 and g33 = 1.987) instigate the contribution of the resonance form, cis-[Rh(II)(PQ)(PPh3)2Cl2] in 3. DFT calculations established that the closed shell singlet (CSS) solutions of 1Me and 2Me are unstable due to open shell singlet (OSS) perturbation. However, the broken symmetry (BS) (1,1) Ms = 0 solutions of 1Me and 2Me are respectively 22.6 and 24.2 kJ mole(-1) lower in energy and reproduced the experimental bond

  16. Robots conquering local government services

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Agger; Andersen, Kim Normann; Sigh, Anne

    2016-01-01

    labour-intensive services, the public administration research community is short on knowledge of the impact on the work processes carried out in public organizations and how staff and clients react toward robots. This case study investigates the implementation and use of robot vacuum cleaners in Danish......The movement of robots from the production line to the service sector provides a potentially radical solution to innovate and transform public service delivery. Although robots are increasingly being adopted in service delivery (e.g., health- and eldercare) to enhance and in some cases substitute...... eldercare, demonstrating how robot vacuums have proven to have considerable interpretive flexibility with variation in the perceived nature of technology, technology strategy, and technology use between key stakeholders in eldercare....

  17. Pathological and 3 Tesla Volumetric Magnetic Resonance Imaging Predictors of Biochemical Recurrence after Robotic Assisted Radical Prostatectomy: Correlation with Whole Mount Histopathology.

    Science.gov (United States)

    Tan, Nelly; Shen, Luyao; Khoshnoodi, Pooria; Alcalá, Héctor E; Yu, Weixia; Hsu, William; Reiter, Robert E; Lu, David Y; Raman, Steven S

    2018-05-01

    We sought to identify the clinical and magnetic resonance imaging variables predictive of biochemical recurrence after robotic assisted radical prostatectomy in patients who underwent multiparametric 3 Tesla prostate magnetic resonance imaging. We performed an institutional review board approved, HIPAA (Health Insurance Portability and Accountability Act) compliant, single arm observational study of 3 Tesla multiparametric magnetic resonance imaging prior to robotic assisted radical prostatectomy from December 2009 to March 2016. Clinical, magnetic resonance imaging and pathological information, and clinical outcomes were compiled. Biochemical recurrence was defined as prostate specific antigen 0.2 ng/cc or greater. Univariate and multivariate regression analysis was performed. Biochemical recurrence had developed in 62 of the 255 men (24.3%) included in the study at a median followup of 23.5 months. Compared to the subcohort without biochemical recurrence the subcohort with biochemical recurrence had a greater proportion of patients with a high grade biopsy Gleason score, higher preoperative prostate specific antigen (7.4 vs 5.6 ng/ml), intermediate and high D'Amico classifications, larger tumor volume on magnetic resonance imaging (0.66 vs 0.30 ml), higher PI-RADS® (Prostate Imaging-Reporting and Data System) version 2 category lesions, a greater proportion of intermediate and high grade radical prostatectomy Gleason score lesions, higher pathological T3 stage (all p <0.01) and a higher positive surgical margin rate (19.3% vs 7.8%, p = 0.016). On multivariable analysis only tumor volume on magnetic resonance imaging (adjusted OR 1.57, p = 0.016), pathological T stage (adjusted OR 2.26, p = 0.02), positive surgical margin (adjusted OR 5.0, p = 0.004) and radical prostatectomy Gleason score (adjusted OR 2.29, p = 0.004) predicted biochemical recurrence. In this cohort tumor volume on magnetic resonance imaging and pathological variables, including Gleason score

  18. Type III radical hysterectomy after induction chemotherapy for patients with locally advanced cervical carcinoma.

    Science.gov (United States)

    Lopez-Graniel, C; Reyes, M; Chanona, G; Gonzalez, A; Robles, E; Mohar, A; Lopez-Basave, H; De La Garza, J G; Dueñas-Gonzalez, A

    2001-01-01

    Neoadjuvant chemotherapy followed by surgery is a promising approach in locally advanced cervical carcinoma. The aim of this study was to evaluate the feasibility, technical aspects, and clinical results of surgery after induction chemotherapy in this patient population. Forty-one untreated cervical carcinoma patients staged as IB2 to IIIB received three 21-day courses of cisplatin 100mg/m2 on day 1 and gemcitabine 1000 mg/m2 on days 1 and 8 followed by surgery or concomitant chemoradiation. The response to chemotherapy, operability, surgical/pathological findings, disease-free period, and survival of the surgically treated patients were evaluated. All 41 patients were evaluated for toxicity and 40 were evaluated for response. The overall objective response rate was 95% (95% confidence interval 88%-100%), and was complete in three patients (7.5%) and partial in 35 (87.5%). Granulocytopenia grades 3/4 occurred in 13.8% and 3.4% of the courses, respectively, whereas nonhematological toxicity was mild. Twenty-three patients underwent type III radical hysterectomy. Mean duration of surgery was 3.8 h (range 2:30-5:20), median estimated blood loss was 670 ml and median hospital stay was 5.2 days. Intraoperative complications occurred in one case (venous injury). In all but one case the resection margins were negative. Four patients (17%) had positive nodes (one node each); six (26%) had complete pathologic response, three (13%) had microscopic; and 14 (60%) macroscopic residual disease. At 24 months of maximum follow-up (median 20), the disease-free and overall survival rates were 59% and 91%, respectively. Induction chemotherapy with cisplatin/gemcitabine produced a high response rate and did not increase the difficulty of surgery. Operating time, blood loss, intraoperative complications, and hospital stay were all within the range observed for type III hysterectomy in early stage patients. We therefore conclude that type III radical hysterectomy is feasible in locally

  19. Reverse-hybrid robotic mesorectal excision for rectal cancer.

    Science.gov (United States)

    Park, In Ja; You, Y Nancy; Schlette, Erika; Nguyen, Sa; Skibber, John M; Rodriguez-Bigas, Miguel A; Chang, George J

    2012-02-01

    The robotic system offers potential technical advantages over laparoscopy for total mesorectal excision with radical lymphadenectomy for rectal cancer. However, the requirement for fixed docking limits its utility when the working volume is large or patient repositioning is required. The purpose of this study was to evaluate short-term outcomes associated with a novel setup to perform total mesorectal excision and radical lymphadenectomy for rectal cancer by the use of a "reverse" hybrid robotic-laparoscopic approach. This is a prospective consecutive cohort observational study of patients who underwent robotic rectal cancer resection from January 2009 to March 2011. During the study period, a technique of reverse-hybrid robotic-laparoscopic rectal resection with radical lymphadenectomy was developed. This technique involves reversal of the operative sequence with lymphovascular and rectal dissection to precede proximal colonic mobilization. This technique evolved from a conventional-hybrid resection with laparoscopic vascular control, colonic mobilization, and robotic pelvic dissection. Perioperative and short-term oncologic outcomes were analyzed. Thirty patients underwent reverse-hybrid resection. Median tumor location was 5 cm (interquartile range 3-9) from the anal verge. Median BMI was 27.6 (interquartile range 25.0-32.1 kg/m). Twenty (66.7%) received neoadjuvant chemoradiation. There were no conversions. Median blood loss was 100 mL (interquartile range 75-200). Total operation time was a median 369 (interquartile range 306-410) minutes. Median docking time was 6 (interquartile range 5-8) minutes, and console time was 98 (interquartile range 88-140) minutes. Resection was R0 in all patients; no patients had an incomplete mesorectal resection. Six patients (20%) underwent extended lymph node dissection or en bloc resection. Reverse-hybrid robotic surgery for rectal cancer maximizes the therapeutic applicability of the robotic and conventional laparoscopic

  20. The evolution of robotic general surgery.

    Science.gov (United States)

    Wilson, E B

    2009-01-01

    Surgical robotics in general surgery has a relatively short but very interesting evolution. Just as minimally invasive and laparoscopic techniques have radically changed general surgery and fractionated it into subspecialization, robotic technology is likely to repeat the process of fractionation even further. Though it appears that robotics is growing more quickly in other specialties, the changes digital platforms are causing in the general surgical arena are likely to permanently alter general surgery. This review examines the evolution of robotics in minimally invasive general surgery looking forward to a time where robotics platforms will be fundamental to elective general surgery. Learning curves and adoption techniques are explored. Foregut, hepatobiliary, endocrine, colorectal, and bariatric surgery will be examined as growth areas for robotics, as well as revealing the current uses of this technology.

  1. Escherichia coli class Ib ribonucleotide reductase contains a dimanganese(III)-tyrosyl radical cofactor in vivo†

    Science.gov (United States)

    Cotruvo, Joseph A.; Stubbe, JoAnne

    2011-01-01

    Escherichia coli class Ib ribonucleotide reductase (RNR) converts nucleoside 5′-diphosphates to deoxynucleoside 5′-diphosphates in iron-limited and oxidative stress conditions. We have recently demonstrated in vitro that this RNR is active with both diferric-tyrosyl radical (FeIII2-Y•) and dimanganese(III)-Y• (MnIII2-Y•) cofactors in the β2 subunit, NrdF [Cotruvo J.A., Jr. and Stubbe J., Biochemistry (2010) 49, 1297–1309]. Here we demonstrate, by purification of this protein from its endogenous levels in an E. coli strain deficient in its five known iron uptake pathways and grown under iron-limited conditions, that the MnIII2-Y• cofactor is assembled in vivo. This is the first definitive determination of the active cofactor of a class Ib RNR purified from its native organism without overexpression. From 88 g of cell paste, 150 μg of NrdF was isolated with ~95% purity, with 0.2 Y•/β2, 0.9 Mn/β2, and a specific activity of 720 nmol/min/mg. In these conditions, the class Ib RNR is the primary active RNR in the cell. Our results strongly suggest that E. coli NrdF is an obligate manganese protein in vivo and that the MnIII2-Y• cofactor assembly pathway we have identified in vitro involving the flavodoxin-like protein NrdI, present inside the cell at catalytic levels, is operative in vivo. PMID:21250660

  2. A study on autonomous maintenance robot, 7

    International Nuclear Information System (INIS)

    Fukuda, Toshio; Hosokai, Hidemi; Shimasaka, Naoki; Kaneshige, Masanori; Iwasaki, Shinnosuke.

    1990-01-01

    This paper deals with the new mechanism of a new maintenance robot, Mark IV, following the previous reports on pipeline inspection and maintenance robots of Mark I, II, and III. The Mark IV has a mechanism capable of inspecting surfaces of storage tanks as well as pipeline outer surfaces, which is another capability of the maintenance robots, different from the previous ones. The main features of Mark IV are as follows, (i) The robot has a multijoint structure, so that it has better adaptability to the curvartures of pipelines and storage tanks. (ii) The joint of the robot has SMA actuators to make the robot lighter in weight. Some actuator shape characteristics are also examined for the robot structure and control. (iii) The robot has suckers at both ends so that the robot can climb up along the wall from the ground. (iv) A robot with the inch worm mechanisms has many functional motions, such that it can pass over flanges and T-joints, and transfer to adjacent pipelines with a wider range of pipe diameters. (v) A control method is given for the mobile motion control. Thus, the functional level of the maintenance robot has been greatly improved by the introduction of the Mark IV robot. (author)

  3. Porphyrin Co(III-Nitrene Radical Mediated Pathway for Synthesis of o-Aminoazobenzenes

    Directory of Open Access Journals (Sweden)

    Monalisa Goswami

    2018-05-01

    Full Text Available Azobenzenes are versatile compounds with a range of applications, including dyes and pigments, food additives, indicators, radical reaction initiators, molecular switches, etc. In this context, we report a general method for synthesizing o-aminoazobenzenes using the commercially available cobalt(II tetraphenyl porphyrin [CoII(TPP]. The net reaction is a formal dimerization of two phenyl azides with concomitant loss of two molecules of dinitrogen. The most commonly used methodology to synthesize azobenzenes is based on the initial diazotization of an aromatic primary amine at low temperatures, which then reacts with an electron rich aromatic nucleophile. As such, this limits the synthesis of azobenzenes with an amine functionality. In contrast, the method we report here relies heavily on the o-amine moiety and retains it in the product. The reaction is metal catalyzed and proceeds through a porphyrin Co(III-nitrene radical intermediate, which is known to form on activation of organic azides at the cobalt center. The synthesized o-aminoazobenzenes are bathochromatically shifted, as compared to azobenzenes without amine substituents. Based on the crystal structure of one of the products, strong H-bonding between the N-atom of the azo functionality and the H of the NH2 substituent is shown to stabilize the trans isomeric form of the product. The NH2 substituents offers possibilities for further functionalization of the synthesized azo compounds.

  4. Robot-assisted urologic surgery in 2010 - Advancements and future outlook

    Directory of Open Access Journals (Sweden)

    Paurush Babbar

    2011-01-01

    Full Text Available Robotic surgery is a cutting edge and minimally invasive procedure, which has generated a great deal of excitement in the urologic community. While there has been much advancement in this emerging technology, it is safe to say that robotic urologic surgery holds tremendous potential for progress in the near future. Hence, it is paramount that urologists stay up-to-date regarding new developments in the realm of robotics with respect to novel applications, limitations and opportunities for incorporation into their practice. Robot-assisted surgery provides an enhanced 3D view, increased magnification of the surgical field, better manual dexterity, relatively bloodless field, elimination of surgeon′s tremor, reduction in a surgeon′s fatigue and mitigation of scattered light. All these factors translate into greater precision of surgical dissection, which is imperative in providing better intraoperative and postoperative outcomes. Pioneering work assessing the feasibility of robotic surgery in urology began in the early 2000′s with robot-assisted radical prostatectomy and has since expanded to procedures such as robot-assisted radical cystectomy, robot-assisted partial nephrectomy, robot-assisted nephroureterectomy and robot-assisted pyeloplasty. A MEDLINE search was used to identify recent articles (within the last two years and publications of specific importance, which highlighted the recent developments and future direction of robotics. This review will use the aforementioned urologic surgeries as vehicles to evaluate the current status and future role of robotics in the advancement of the field of urology.

  5. Surgery-related complications in 1253 robot-assisted and 485 open retropubic radical prostatectomies at the Karolinska University Hospital, Sweden.

    Science.gov (United States)

    Carlsson, Stefan; Nilsson, Andreas E; Schumacher, Martin C; Jonsson, Martin N; Volz, Daniela S; Steineck, Gunnar; Wiklund, Peter N

    2010-05-01

    To quantify complications to surgery in patients treated with robot-assisted radical prostatectomy (RARP) and open retropubic radical prostatectomy (RRP) at our institution. Radical prostatectomy is associated with specific complications that can affect outcome results in patients. Between January 2002 and August 2007, a series of 1738 consecutive patients underwent RARP (n = 1253) or RRP (n = 485) for clinically localized prostate cancer. Surgery-related complications were assessed using a prospective hospital-based complication registry. The baseline characteristics of all patients were documented preoperatively. Overall, 170 patients required blood transfusions (9.7%), 112 patients (23%) in the RRP group compared with 58 patients (4.8%) in the RARP group. Infectious complications occurred in 44 RRP patients (9%) compared with 18 (1%) in the RARP group. Bladder neck contracture was treated in 22 (4.5%) patients who had undergone RRP compared with 3 (0.2%) in the RARP group. Clavien grade IIIb-V complications were more common in RRP patients (n = 63; 12.9%) than in RARP patients (n = 46; 3.7%). The introduction of RARP at our institution has resulted in decreased number of patients with Clavien grade IIIb-V complications, such as bladder neck contractures, a decrease in the number of patients who require blood transfusions, and decreased numbers of patients with postoperative wound infections. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Patterns-of-care and health economic analysis of robot-assisted radical prostatectomy in the Australian public health system.

    Science.gov (United States)

    Basto, Marnique; Sathianathen, Niranjan; Te Marvelde, Luc; Ryan, Shane; Goad, Jeremy; Lawrentschuk, Nathan; Costello, Anthony J; Moon, Daniel A; Heriot, Alexander G; Butler, Jim; Murphy, Declan G

    2016-06-01

    To compare patterns of care and peri-operative outcomes of robot-assisted radical prostatectomy (RARP) with other surgical approaches, and to create an economic model to assess the viability of RARP in the public case-mix funding system. We retrospectively reviewed all radical prostatectomies (RPs) performed for localized prostate cancer in Victoria, Australia, from the Victorian Admitted Episode Dataset, a large administrative database that records all hospital inpatient episodes in Victoria. The first database, covering the period from July 2010 to April 2013 (n = 5 130), was used to compare length of hospital stay (LOS) and blood transfusion rates between surgical approaches. This was subsequently integrated into an economic model. A second database (n = 5 581) was extracted to cover the period between July 2010 and June 2013, three full financial years, to depict patterns of care and make future predictions for the 2014-2015 financial year, and to perform a hospital volume analysis. We then created an economic model to evaluate the incremental cost of RARP vs open RP (ORP) and laparoscopic RP (LRP), incorporating the cost-offset from differences in LOS and blood transfusion rate. The economic model constructs estimates of the diagnosis-related group (DRG) costs of ORP and LRP, adds the gross cost of the surgical robot (capital, consumables, maintenance and repairs), and manipulates these DRG costs to obtain a DRG cost per day, which can be used to estimate the cost-offset associated with RARP in comparison with ORP and LRP. Economic modelling was performed around a base-case scenario, assuming a 7-year robot lifespan and 124 RARPs performed per financial year. One- and two-way sensitivity analyses were performed for the four-arm da Vinci SHD, Si and Si dual surgical systems (Intuitive Surgical Ltd, Sunnyvale, CA, USA). We identified 5 581 patients who underwent RP in 20 hospitals in Victoria with an open, laparoscopic or robot-assisted surgical approach in the

  7. Preliminary study on the photoproduction of hydroxyl radicals in aqueous solution with Aldrich humic acid, algae and Fe(III) under high-pressure mercury lamp irradiation.

    Science.gov (United States)

    Liu, Xianli; Xu, Dong; Wu, Feng; Liao, Zhenhuan; Liu, Jiantong; Deng, Nansheng

    2004-03-01

    Under a high-pressure mercury lamp (HPML) and using an exposure time of 4 h, the photoproduction of hydroxyl radicals (*OH) could be induced in an aqueous solution containing humic acid (HA). Hydroxyl radicals were determined by high-performance liquid chromatography using benzene as a probe. The results showed that *OH photoproduction increased from 1.80 to 2.74 microM by increasing the HA concentration from 10 to 40 mg L(-1) at an exposure time of 4 h (pH 6.5). Hydroxyl radical photoproduction in aqueous solutions of HA containing algae was greater than that in the aqueous solutions of HA without algae. The photoproduction of *OH in the HA solution with Fe(III) was greater than that of the solution without Fe(III) at pH ranging from 4.0 to 8.0. The photoproduction of *OH in HA solution with algae with or without Fe(III) under a 250 W HPML was greater than that under a 125 W HPML. The photoproduction of *OH in irradiated samples was influenced by the pH. The results showed that HPML exposure for 4 h in the 4-8 pH range led to the highest *OH photoproduction at pH 4.0.

  8. Robot-assisted partial nephrectomy in contemporary practice

    Directory of Open Access Journals (Sweden)

    Youssef S. Tanagho

    2013-01-01

    Full Text Available Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy for the management of small renal masses. While offering similar oncological outcomes to laparoscopic radical nephrectomy, the technical challenges and prolonged learning curve associated with laparoscopic partial nephrectomy limit its wider dissemination. Robot-assisted partial nephrectomy, although still an evolving procedure with no long-term data, has emerged as a viable alternative to laparoscopic partial nephrectomy, with favorable preliminary outcomes. This article provides an overview of the role of robot-assisted partial nephrectomy in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of robot-assisted partial nephrectomy are also evaluated, as are complication rates.

  9. Redox potentials of free radicals. III. Reevaluation of the method

    International Nuclear Information System (INIS)

    Rao, P.S.; Hayon, E.

    1974-01-01

    A reevaluation of the method described in ref 1 and 2 to determine the redox potentials of free radicals (.RH) in water using the techniques of pulse radiolysis and absorption spectrophotometry is presented. This method is based on the dependence of the percentage efficiency for the one-electron oxidation (or reduction) of .RH radicals on the redox potentials E 01 of the electron acceptors, A. The reaction .RH + A → .A - + R + H + (kappa/sub ox/) is not reversible for most radicals under the experimental conditions used, and the derived potentials are, therefore, not thermodynamic values. A reinterpretation of the results is made on the basis of the kinetic competition between the above reaction and .RH + A → .RHA (kappa/sub add/) (radical adducts). Based on kappa/ sub ox/ and kappa/sub add/, it is concluded that the observed experimental ''titration'' curves do represent a measure of the redox property of the free radicals. From the midpoint on the curves, the kinetic potential, E/sub kappa/ 01 : of the free radicals can be derived based on the known two-electron redox potentials of the electron acceptors. These and other questions are discussed. (U.S.)

  10. Health-related quality of life from a prospective randomised clinical trial of robot-assisted laparoscopic vs open radical cystectomy.

    Science.gov (United States)

    Messer, Jamie C; Punnen, Sanoj; Fitzgerald, John; Svatek, Robert; Parekh, Dipen J

    2014-12-01

    To compare health-related quality-of-life (HRQoL) outcomes for robot-assisted laparoscopic radical cystectomy (RARC) with those of traditional open radical cystectomy (ORC) in a prospective randomised fashion. This was a prospective randomised clinical trial evaluating the HRQoL for ORC vs RARC in consecutive patients from July 2009 to June 2011. We administered the Functional Assessment of Cancer Therapy-Vanderbilt Cystectomy Index questionnaire, validated to assess HRQoL, preoperatively and then at 3, 6, 9 and 12 months postoperatively. Scores for each domain and total scores were compared in terms of deviation from preoperative values for both the RARC and the ORC cohorts. Multivariate linear regression was used to assess the association between the type of radical cystectomy and HRQoL. At the time of the study, 47 patients had met the inclusion criteria, with 40 patients being randomised for analysis. The cohorts consisted of 20 patients undergoing ORC and 20 undergoing RARC, who were balanced with respect to baseline demographic and clinical features. Univariate analysis showed a return to baseline scores at 3 months postoperatively in all measured domains with no statistically significant difference among the various domains between the RARC and the ORC cohorts. Multivariate analysis showed no difference in HRQoL between the two approaches in any of the various domains, with the exception of a slightly higher physical well-being score in the RARC group at 6 months. There were no significant differences in the HRQoL outcomes between ORC and RARC, with a return of quality of life scores to baseline scores 3 months after radical cystectomy in both cohorts. © 2014 The Authors. BJU International © 2014 BJU International.

  11. [Individual learning curve for radical robot-assisted prostatectomy based on the example of three professionals working in one clinic].

    Science.gov (United States)

    Rasner, P I; Pushkar', D Iu; Kolontarev, K B; Kotenkov, D V

    2014-01-01

    The appearance of new surgical technique always requires evaluation of its effectiveness and ease of acquisition. A comparative study of the results of the first three series of successive robot-assisted radical prostatectomy (RARP) performed on at time by three surgeons, was conducted. The series consisted of 40 procedures, and were divided into 4 groups of 10 operations for the analysis. When comparing data, statistically significant improvement of intra- and postoperative performance in each series was revealed, with increase in the number of operations performed, and in each subsequent series compared with the preceding one. We recommend to perform the planned conversion at the first operation. In our study, previous laparoscopic experience did not provide any significant advantages in the acquisition of robot-assisted technology. To characterize the individual learning curve, we recommend the use of the number of operations that the surgeon looked in the life-surgery regimen and/or in which he participated as an assistant before his own surgical activity, as well as the indicator "technical defect". In addition to the term "individual learning curve", we propose to introduce the terms "surgeon's individual training phase", and "clinic's learning curve".

  12. Role of robot-assisted radical prostatectomy in the management of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Akshay Sood

    2014-01-01

    Full Text Available We aimed to evaluate the role of robot-assisted radical prostatectomy (RARP in the management of high-risk prostate cancer (PCa, with a focus on oncological, functional and perioperative outcomes. Further, we also aimed to briefly describe our novel modification to conventional RARP that allows immediate organ retrieval and examination for intra-operative surgical margin assessment. A literature search of PubMed was performed for articles on the management of high-risk PCa. Papers written in English and concerning clinical outcomes following RARP for locally advanced and high-risk PCa were selected. Outcomes data from our own center were also included. A total of 10 contemporary series were evaluated. Biopsy Gleason score ≥ 8 was the most common cause for classification of patients into the high-risk PCa group. Biochemical failure rate, in the few series that looked at long-term follow-up, varied from 9% to 26% at 1 year. The positive surgical margin rate varied from 12% to 53.3%. Urinary continence rates varied from 78% to 92% at 1 year. The overall complication rates varied from 2.4% to 30%, with anastomotic leak and lymphocele being the most common complications. Long-term data on oncological control following RARP in high-risk patients is lacking. Short-term oncological outcomes and functional outcomes are equivalent to open radical prostatectomy (RP. Safety outcomes are better in patients undergoing RARP when compared with open RP. Improved tools for predicting the presence of organ-confined disease (OCD are available. High-risk patients with OCD would be ideal candidates for RARP and would benefit most from surgery alone.

  13. Development of robotic program: an Asian experience.

    Science.gov (United States)

    Sahabudin, R M; Arni, T; Ashani, N; Arumuga, K; Rajenthran, S; Murali, S; Patel, V; Hemal, A; Menon, M

    2006-06-01

    Robotic surgery was started in the Department of Urology, Hospital Kuala Lumpur, in April 2004. We present our experience in developing the program and report the results of our first 50 cases of robotic radical prostatectomy. A three-arm da Vinci robotic system was installed in our hospital in March 2004. Prior to installation, the surgeons underwent training at various centers in the United States and Paris. The operating theatre was renovated to house the system. Subsequently, the initial few cases were done with the help of proctors. Data were prospectively collected on all patients who underwent robot-assisted radical prostatectomy for localized carcinoma of the prostate. Fifty patients underwent robot assisted radical prostatectomy from March 2004 to June 2005. Their ages ranged from 52 to 75 years, (average age 60.2 years). PSA levels ranged from 2.5 to 35 ng/ml (mean 10.6 ng/ml). Prostate volume ranged from 18 to 130 cc (average 32.4 cc). Average operating time for the first 20 cases was 4 h and for the next 30 cases was 2.5 h. Patients were discharged 1-3 days post-operatively. Catheters were removed on the fifth day following a cystogram. The positive margin rate as defined by the presence of cancer cells at the inked margin was 30%. Twenty-one patients had T1c disease and one had T1b on clinical staging. Of these, two were apical margin positive. Twenty-six patients had T2 disease and eight of them were apical margin positive. Two patients had T3 disease, one of whom was apical margin positive. Five patients (10%) had PSA recurrence. Five patients had a poorly differentiated carcinoma and the rest had Gleason 6 or 7. Eighty percent of the patients were continent on follow-up at 3 months. Of those who were potent before the surgery, 50% were potent at 3-6 months. The robotic surgery program was successfully implemented at our center on the lines of a structured program, developed at Vattikuti Urology Institute (VUI). We succeeded in creating a team and

  14. Comprehensive analysis of sexual function outcome in prostate cancer patients after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Woo, Seung Hyo; Kang, Dong Il; Ha, Yun-Sok; Salmasi, Amirali Hassanzadeh; Kim, Jeong Hyun; Lee, Dong-Hyeon; Kim, Wun-Jae; Kim, Isaac Yi

    2014-02-01

    The recovery of potency following radical prostatectomy is complex and has a very wide range. In this study, we analyzed in detail the precise pattern of recovery of potency following robot-assisted radical prostatectomy (RARP). Prospectively collected database of patients with a minimum follow-up of 1 year after RARP were evaluated retrospectively. Of 503 patients identified, 483 patients completed the sexual health inventory for men (SHIM) preoperatively and postoperatively every 3 months for the first 12 months. Overall potency, usage of phosphodiesterase type-5 (PDE-5) inhibitors, and return to baseline erectile function were evaluated. Potency was defined as having erection that is sufficient for sexual intercourse more than 50% of attempts, while quality potency was defined as being potent without the use of PDE-5 inhibitors. Preoperatively, the overall potency and quality potency rate were 67.1% and 48.1%, respectively. Postoperatively, the overall potency rate was 61.4%, while the quality potency rate was 37.2%. In multivariate regression analysis, independent predictors of potency recovery were young age (21, the overall potency and quality potency rate were 79.7% and 41.2%, respectively. More importantly, only 21.4% of the men with normal erection preoperatively (SHIM>21) returned to baseline erectile function (SHIM>21) 12 months after surgery. This study indicates that young age (<60), preoperative potency, and bilateral preservation of NVBs were positive predictors of potency recovery following RARP. However, an overwhelming majority of men experience a deterioration in the overall quality of erection after RARP.

  15. Radical transfer between proteins: role of tyrosine, tryptophan and protein peroxyl radicals

    International Nuclear Information System (INIS)

    Irwin, J.A.; Ostdal, H.; Davies, M.J.

    1998-01-01

    Reaction of the Fe(III) forms of the heme proteins myoglobin (Mb) and horseradish peroxidase (HRP) with H 2 O 2 gives rise to high-oxidation-state heme-derived species which can be described as a Fe(IV)-oxo porphyrin radical-cation ('Compound 1'). In the case of Mb, the Fe(IV)-oxo porphyrin radical-cation undergoes rapid electron transfer with the surrounding protein to give protein (globin)-derived radicals and an Fe(lV)-oxo species ('Compound 2'). The globin-derived radicals have been shown to be located at two (or more) sites: Tyr-103 or Trp-14, with the latter radical known to react with oxygen to give a Trp-derived peroxyl radical (Mb-Trp-OO*). With HRP, the Fe(lV)-oxo porphyrin radical-cation carries out two successive one-electron oxidation reactions at the exposed heme edge to give firstly 'Compound 2' [the Fe(lV)oxo species] and then the resting Fe(III) state of the enzyme. n this study we have investigated whether the Trp-14 peroxyl radical from Mb and the Compound 1 and 2 species from HRP (in the absence and presence of free Tyr) can oxidise amino acids, peptides and proteins. Such reactions constitute intermolecular protein-to-protein radical transfer reactions and hence protein chain-oxidation. We have also examined whether these oxidants react with antioxidants. Reaction of these heme-protein derived oxidants with amino acids, proteins and antioxidants has been carried out at room temperature for defined periods of time before freeze-quenching to 77K to halt reaction. The radical species present in the reaction system at the time of freezing were subsequently examined by EPR spectroscopy at 77K. Three free amino acids, Tyr, Trp and Cys (with Cys the least efficient) have been shown to react rapidly with Mb-Trp-OO*, as evidenced by the loss of the characteristic EPR features of Mb-Trp-OO* on inclusion of increasing concentrations of the amino acids. All other amino acids are much less reactive. Evidence has also been obtained for (inefficient) hydrogen

  16. [Have Case Loads of Radical Surgery for Prostate Cancer Been Concentrated in Hospitals with Robotic Equipment ?--Analyses with Questionnaire Survey and Diagnostic Procedure Combination (DPC) Data].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2016-04-01

    We investigated whether installation of robot-assisted surgical equipment in hospitals resulted in concentration of the case loads of radical prostatectomy. We selected 11 areas with populations of around 1 million or more where there were one or more hospitals with robotic equipment and 4 or more without it. In addition, annual changes of case loads for prostatectomy over 4 years from 2010 to 2013 were clearly determined in these areas. The case loads were determined based on the results of a questionnaire survey for the hospitals with robots and on the Diagnostic Procedures Combination data provided by the Ministry of Health, Labor and Wealth for those without such equipment. The concentration of the case loads was principally defined as when hospitals with robots had more predominant proportion of cases than those without them in the comparison between case loads prior to instillation of robots (or in the initial year of the study) and those in the final years. The 11 selected areas included 44 hospitals with robots and 156 without them. Concentration of case loads was found in 5 areas. In 4 areas, installation of robots did not have a specific relation to the distribution pattern s of case loads in hospitals with or without the equipment. The remaining 2 areas tended to have a weak but not definite concentration of case loads. In the areas in which installation did not influence case loads the further analysis revealed that their case loads had already been concentrated in the initial year (2010) of the study. Although the current results were found in a single department of the hospital, robotic installation may result in concentration of prostatectomy case loads for such hospitals in some areas. The current results are intriguing when we consider the future roles of acute care hospitals and beds in our country where the number of aged patients having chronic diseases will increase. In conclusion, installation of robotic equipment may result in concentration

  17. Robotic surgical education: a collaborative approach to training postgraduate urologists and endourology fellows.

    Science.gov (United States)

    Mirheydar, Hossein; Jones, Marklyn; Koeneman, Kenneth S; Sweet, Robert M

    2009-01-01

    Currently, robotic training for inexperienced, practicing surgeons is primarily done vis-à-vis industry and/or society-sponsored day or weekend courses, with limited proctorship opportunities. The objective of this study was to assess the impact of an extended-proctorship program at up to 32 months of follow-up. An extended-proctorship program for robotic-assisted laparoscopic radical prostatectomy was established at our institution. The curriculum consisted of 3 phases: (1) completing an Intuitive Surgical 2-day robotic training course with company representatives; (2) serving as assistant to a trained proctor on 5 to 6 cases; and (3) performing proctored cases up to 1 year until confidence was achieved. Participants were surveyed and asked to evaluate on a 5-point Likert scale their operative experience in robotics and satisfaction regarding their training. Nine of 9 participants are currently performing robotic-assisted laparoscopic radical prostatectomy (RALP) independently. Graduates of our program have performed 477 RALP cases. The mean number of cases performed within phase 3 was 20.1 (range, 5 to 40) prior to independent practice. The program received a rating of 4.2/5 for effectiveness in teaching robotic surgery skills. Our robotic program, with extended proctoring, has led to an outstanding take-rate for disseminating robotic skills in a metropolitan community.

  18. Elements of Autonomous Self-Reconfigurable Robots

    DEFF Research Database (Denmark)

    Christensen, David Johan

    In this thesis, we study several central elements of autonomous self-reconfigurable modular robots. Unlike conventional robots such robots are: i) Modular, since robots are assembled from numerous robotic modules. ii) Reconfigurable, since the modules can be combined in a variety of ways. iii) Self......-reconfigurable, since the modules themselves are able to change how they are combined. iv) Autonomous, since robots control themselves without human guidance. Such robots are attractive to study since they in theory have several desirable characteristics, such as versatility, reliability and cheapness. In practice...... however, it is challenging to realize such characteristics since state-of-the-art systems and solutions suffer from several inherent technical and theoretical problems and limitations. In this thesis, we address these challenges by exploring four central elements of autonomous self-reconfigurable modular...

  19. Tank-automotive robotics

    Science.gov (United States)

    Lane, Gerald R.

    1999-07-01

    To provide an overview of Tank-Automotive Robotics. The briefing will contain program overviews & inter-relationships and technology challenges of TARDEC managed unmanned and robotic ground vehicle programs. Specific emphasis will focus on technology developments/approaches to achieve semi- autonomous operation and inherent chassis mobility features. Programs to be discussed include: DemoIII Experimental Unmanned Vehicle (XUV), Tactical Mobile Robotics (TMR), Intelligent Mobility, Commanders Driver Testbed, Collision Avoidance, International Ground Robotics Competition (ICGRC). Specifically, the paper will discuss unique exterior/outdoor challenges facing the IGRC competing teams and the synergy created between the IGRC and ongoing DoD semi-autonomous Unmanned Ground Vehicle and DoT Intelligent Transportation System programs. Sensor and chassis approaches to meet the IGRC challenges and obstacles will be shown and discussed. Shortfalls in performance to meet the IGRC challenges will be identified.

  20. The efficacy and utilisation of preoperative multiparametric magnetic resonance imaging in robot-assisted radical prostatectomy: does it change the surgical dissection plan?

    Science.gov (United States)

    Tavukçu, Hasan Hüseyin; Aytaç, Ömer; Balcı, Numan Cem; Kulaksızoğlu, Haluk; Atuğ, Fatih

    2017-12-01

    We investigated the effect of the use of multiparametric prostate magnetic resonance imaging (mp-MRI) on the dissection plan of the neurovascular bundle and the oncological results of our patients who underwent robot-assisted radical prostatectomy. We prospectively evaluated 60 consecutive patients, including 30 patients who had (Group 1), and 30 patients who had not (Group 2) mp-MRI before robot-assisted radical prostatectomy. Based on the findings of mp-MRI, the dissection plan was changed as intrafascial, interfascial, and extrafascial in the mp-MRI group. Two groups were compared in terms of age, prostate-specific antigen (PSA), Gleason sum scores and surgical margin positivity. There was no statistically significant difference between the two groups in terms of age, PSA, biopsy Gleason score, final pathological Gleason score and surgical margin positivity. mp-MRI changed the initial surgical plan in 18 of 30 patients (60%) in Group 1. In seventeen of these patients (56%) surgical plan was changed from non-nerve sparing to interfascial nerve sparing plan. In one patient dissection plan was changed to non-nerve sparing technique which had extraprostatic extension on final pathology. Surgical margin positivity was similar in Groups 1, and 2 (16% and 13%, respectively) although, Group 1 had higher number of high- risk patients. mp-MRI confirmed the primary tumour localisation in the final pathology in 27 of of 30 patients (90%). Preoperative mp-MRI effected the decision to perform a nerve-sparing technique in 56% of the patients in our study; moreover, changing the dissection plan from non-nerve-sparing technique to a nerve sparing technique did not increase the rate of surgical margin positivity.

  1. Catheter-less robotic radical prostatectomy using a custom-made synchronous anastomotic splint and vesical urinary diversion device: report of the initial series and perioperative outcomes.

    Science.gov (United States)

    Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil

    2008-09-01

    To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.

  2. [Short-term efficacy of da Vinci robotic surgical system on rectal cancer in 101 patients].

    Science.gov (United States)

    Zeng, Dong-Zhu; Shi, Yan; Lei, Xiao; Tang, Bo; Hao, Ying-Xue; Luo, Hua-Xing; Lan, Yuan-Zhi; Yu, Pei-Wu

    2013-05-01

    To investigate the feasibility and safety of da Vinci robotic surgical system in rectal cancer radical operation, and to summarize its short-term efficacy and clinical experience. Data of 101 cases undergoing da Vinci robotic surgical system for rectal cancer radical operation from March 2010 to September 2012 were retrospectively analyzed. Evaluation was focused on operative procedure, complication, recovery and pathology. All the 101 cases underwent operation successfully and safely without conversion to open procedure. Rectal cancer radical operation with da Vinci robotic surgical system included 73 low anterior resections and 28 abdominoperineal resections. The average operative time was (210.3±47.2) min. The average blood lose was (60.5±28.7) ml without transfusion. Lymphadenectomy harvest was 17.3±5.4. Passage of first flatus was (2.7±0.7) d. Distal margin was (5.3±2.3) cm without residual cancer cells. The complication rate was 6.9%, including anastomotic leakage(n=2), perineum incision infection(n=2), pulmonary infection (n=2), urinary retention (n=1). There was no postoperative death. The mean follow-up time was(12.9±8.0) months. No local recurrence was found except 2 cases with distant metastasis. Application of da Vinci robotic surgical system in rectal cancer radical operation is safe and patients recover quickly The short-term efficacy is satisfactory.

  3. Early Experience with Robot-assisted Laparoscopic Radical Prostatectomy

    Directory of Open Access Journals (Sweden)

    Hong Gee Sim

    2004-10-01

    Conclusions: rLRP is feasible in a practice with a low volume of radical prostatectomies. Significant improvement in perioperative parameters occurs after the first eight cases. This technique confers the benefits of enhanced precision and dexterity for complex laparoscopic work in the pelvic cavity.

  4. ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation

    Directory of Open Access Journals (Sweden)

    Tobias Nef

    2009-01-01

    Full Text Available Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

  5. Retzus-sparing robotic-assisted laparoscopic radical prostatectomy: a step–by-step technique description of this first brazilian experience

    Directory of Open Access Journals (Sweden)

    Marcos Tobias-Machado

    Full Text Available Abstract Introduction: Retzus-sparing robotic-assisted radical prostatectomy(RARP is a newly approach that preserve the Retzus structures and provide better recovery of continence and erectile function. In Brazil, this approach has not yet been previously reported. Objective: Our goal is to describe Step-by-Step the Retzus-sparing RARP surgical technique and report our first Brazilian experience. Methods: We present a case of a 60-year-old white man with low risk prostate cancer. Surgical materials were four arms Da Vinci robotic platform system, six transperitoneal portals, two prolene wires and Polymer Clips. This surgical technique was step-by-step described according to Galfano et al. One additional step was added as a modification of Galfano et al. Primary technique description: The closure of the Denovellier fascia. Results: We have operated one patient with this technique. The operative time was 180minutes, console time was135 min, the blood loss was 150ml, none perioperative or postoperative complications was found, hospital stay of 01 day. The anatomopathological classification revealed a pT2aN0M0 specimen with free surgical margins. The patient achieved continence immediately after bladder stent retrieval. Full erection reported after 30 days of surgery. Conclusion: Retzus-sparing RARP approach is feasible and reproducible. However, further comparative studies are necessary to demonstrate potential benefits in continence and sexual outcomes over the standard approaches.

  6. Treatment of carcinoma of uterine cervix stage III by adriamycin, bleomycin and cisplatinum, neoadjuvant, modified radical hysterectomy and adjuvant chemotherapy

    International Nuclear Information System (INIS)

    Valle, J.C. do; Ribeiro, C.W.; Rezende, Magda C.; Figueiredo, E.; Chu, C.

    1987-01-01

    Forty-eight patients with untreated carcinoma of the cervix stage III A and IIIB, were submitted to 3 to 5 cycles of a combination of adriamycin (ADR), bleomycin (BLEO) and cisplatinum (CDDP), followed by modified radical hysterectomy and adjuvant chemotherapy, 6 cycles, of the same association. The surgical aspect is emphasized and the operative sequence is described. A comparative evaluation between the treatment presented and the radiotherapy is done. The survical rate is studied. (M.A.C.) [pt

  7. Total robotic radical rectal resection with da Vinci Xi system: single docking, single phase technique.

    Science.gov (United States)

    Tamhankar, Anup Sunil; Jatal, Sudhir; Saklani, Avanish

    2016-12-01

    This study aims to assess the advantages of Da Vinci Xi system in rectal cancer surgery. It also assesses the initial oncological outcomes after rectal resection with this system from a tertiary cancer center in India. Robotic rectal surgery has distinct advantages over laparoscopy. Total robotic resection is increasing following the evolution of hybrid technology. The latest Da Vinci Xi system (Intuitive Surgical, Sunnyvale, USA) is enabled with newer features to make total robotic resection possible with single docking and single phase. Thirty-six patients underwent total robotic resection in a single phase and single docking. We used newer port positions in a straight line. Median distance from the anal verge was 4.5 cm. Median robotic docking time and robotic procedure time were 9 and 280 min, respectively. Median blood loss was 100 mL. One patient needed conversion to an open approach due to advanced disease. Circumferential resection margin and longitudinal resection margins were uninvolved in all other patients. Median lymph node yield was 10. Median post-operative stay was 7 days. There were no intra-operative adverse events. The latest Da Vinci Xi system has made total robotic rectal surgery feasible in single docking and single phase. With the new system, four arm total robotic rectal surgery may replace the hybrid technique of laparoscopic and robotic surgery for rectal malignancies. The learning curve for the new system appears to be shorter than anticipated. Early perioperative and oncological outcomes of total robotic rectal surgery with the new system are promising. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    Science.gov (United States)

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  9. Fifteen years of experience radical cystectomy and intestinal urinary diversion

    Directory of Open Access Journals (Sweden)

    M. I. Vasil’chenko

    2017-01-01

    Full Text Available Objective. Examination of the results of surgical treatment and analysis of the surgical technique and perioperative parameters in a series of radical cystectomy on the basis of its own 15 years of experience in the formation of orthotopic and heterotopic urinary reservoir of the ileum segment by developed and patented techniques in different versions: open radical cystectomy, laparoscopic radical cystectomy and robotassisted radical cystectomy.Materials and methods. A retrospective analysis of 310 radical cystectomy performed from 2000 to 2015, on the occasion of various pathologies of the bladder and prostate, as well as cancers of other organs (uterus, colon with involvement in the process of bladder tumor. Plastics of the bladder was performed from the segment of the terminal ileum. Formation of orthotopic bladder was performed by the method of M.I. Vasilchenko (RF patent for invention № 2337630 “Method of orthotopic bladder plastics” by M.I. Vasilchenko. The ureters are implanted by antireflux procedure. If unable to perform orthotopic bladder plastics recovery and self-urination, patients underwent the formation of heterotopic enteral reservoir with a holding valve.Results. It assesses the functionality and viability of organic shaped orthotopic and heterotopic urinary neocystis in the early and late postoperative periods in different versions. The proposed techniques have a beneficial effect on the improvement of the functional state and stabilization of the upper urinary tract. Analysis of morbidity and mortality was determined according to the classification of surgical complications on the Clavien–Dindo. This approach allowed to identify most of the complications and prevent an underestimation of the main negative results. Estimated oncologic efficacy of minimally invasive interventions laparoscopic radical cystectomy and robot-assisted radical cystectomy not inferior open radical cystectomy.Conclusions. Formation of

  10. Hybrid Locomotion Evaluation for a Novel Amphibious Spherical Robot

    Directory of Open Access Journals (Sweden)

    Huiming Xing

    2018-01-01

    Full Text Available We describe the novel, multiply gaited, vectored water-jet, hybrid locomotion-capable, amphibious spherical robot III (termed ASR-III featuring a wheel-legged, water-jet composite driving system incorporating a lifting and supporting wheel mechanism (LSWM and mechanical legs with a water-jet thruster. The LSWM allows the ASR-III to support the body and slide flexibly on smooth (flat terrain. The composite driving system facilitates two on-land locomotion modes (sliding and walking and underwater locomotion mode with vectored thrusters, improving adaptability to the amphibious environment. Sliding locomotion improves the stability and maneuverability of ASR-III on smooth flat terrain, whereas walking locomotion allows ASR-III to conquer rough terrain. We used both forward and reverse kinematic models to evaluate the walking and sliding gait efficiency. The robot can also realize underwater locomotion with four vectored water-jet thrusters, and is capable of forward motion, heading angle control and depth control. We evaluated LSWM efficiency and the sliding velocities associated with varying extensions of the LSWM. To explore gait stability and mobility, we performed on-land experiments on smooth flat terrain to define the optimal stride length and frequency. We also evaluated the efficacy of waypoint tracking when the sliding gait was employed, using a closed-loop proportional-integral-derivative (PID control mechanism. Moreover, experiments of forward locomotion, heading angle control and depth control were conducted to verify the underwater performance of ASR-III. Comparison of the previous robot and ASR-III demonstrated the ASR-III had better amphibious motion performance.

  11. Handling uncertainty and networked structure in robot control

    CERN Document Server

    Tamás, Levente

    2015-01-01

    This book focuses on two challenges posed in robot control by the increasing adoption of robots in the everyday human environment: uncertainty and networked communication. Part I of the book describes learning control to address environmental uncertainty. Part II discusses state estimation, active sensing, and complex scenario perception to tackle sensing uncertainty. Part III completes the book with control of networked robots and multi-robot teams. Each chapter features in-depth technical coverage and case studies highlighting the applicability of the techniques, with real robots or in simulation. Platforms include mobile ground, aerial, and underwater robots, as well as humanoid robots and robot arms. Source code and experimental data are available at http://extras.springer.com. The text gathers contributions from academic and industry experts, and offers a valuable resource for researchers or graduate students in robot control and perception. It also benefits researchers in related areas, such as computer...

  12. Intraoperative frozen pathology during robot-assisted laparoscopic radical prostatectomy: can ALEXIS™ trocar make it easy and fast?

    Science.gov (United States)

    Almeida, Gilberto Laurino; Musi, Gennaro; Mazzoleni, Federica; Matei, Deliu Victor; Brescia, Antonio; Detti, Serena; de Cobelli, Ottavio

    2013-10-01

    To describe the first series of robot-assisted laparoscopic radical prostatectomy (RALP) using the ALEXIS™ trocar device when removal of the specimen is necessary for intraoperative frozen-section pathology. Consecutive RALP using the ALEXIS were prospectively catalogue. Perioperative data, including preoperative oncologic diagnosis, operative time, estimated blood loss (EBL), size of incision for umbilical trocar, complications related to trocar, and length of hospital stay, were analyzed. One hundred twenty-eight patients were analyzed. The mean operative time was 216 minutes, mean time to trocar placement was 4 minutes, and mean EBL was 172 mL. The incision size for a trocar was 2-3 cm in 117 patients and 1 incisional hernia was observed. The mean hospital stay was 3 days and mean follow-up was 4 months. The ALEXIS trocar provides an easy and fast intraoperative removal of the specimen for frozen pathology during RALP, even for large prostates. Safe and cosmetic results with a low intraoperative complication rate are acquired with the wound retractor.

  13. Muoniated acyl and thioacyl radicals

    International Nuclear Information System (INIS)

    McKenzie, Iain; Brodovitch, Jean-Claude; Ghandi, Khashayar; Percival, Paul W.

    2006-01-01

    The product of the reaction of muonium with tert-butylisocyanate was previously assigned as the muoniated tert-butylaminyl radical (I. McKenzie, J.-C. Brodovitch, K. Ghandi, S. Kecman, P. W. Percival, Physica B 326 (2003) 76). This assignment is incorrect since the muon and 14 N hyperfine-coupling constants (hfcc) of this radical would have the opposite sign, which is in conflict with the experimental results. The radical is now reassigned as the muoniated N-tert-butylcarbamoyl radical, based on the similarities between the experimental muon and 14 N hfcc and hfcc calculated at the UB3LYP/6-311G(d,p)//UB3LYP/EPR-III level. The large zero-point energy in the N-Mu bond results in the dissociation barrier of the muoniated N-tert-butylcarbamoyl radical being above the combined energy of the reactants, in contrast to the N-tert-butylcarbamoyl radical where the dissociation barrier lies below the combined energy of the reactants. The reaction of muonium with tert-butylisothiocyanate produced both conformers of the muoniated N-tert-butylthiocarbamoyl radical and their assignment was based on the similarities between the experimental and calculated muon hfcc. These are the first acyl and thioacyl radicals to be directly detected by muon spin spectroscopy

  14. Muoniated acyl and thioacyl radicals

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, Iain [TRIUMF and Department of Chemistry, 8888 University Drive, Simon Fraser University, Burnaby B.C., V5A 1S6 (Canada); Brodovitch, Jean-Claude [TRIUMF and Department of Chemistry, 8888 University Drive, Simon Fraser University, Burnaby B.C., V5A 1S6 (Canada); Ghandi, Khashayar [TRIUMF and Department of Chemistry, 8888 University Drive, Simon Fraser University, Burnaby B.C., V5A 1S6 (Canada); Percival, Paul W. [TRIUMF and Department of Chemistry, 8888 University Drive, Simon Fraser University, Burnaby B.C., V5A 1S6 (Canada)]. E-mail: percival@sfu.ca

    2006-03-31

    The product of the reaction of muonium with tert-butylisocyanate was previously assigned as the muoniated tert-butylaminyl radical (I. McKenzie, J.-C. Brodovitch, K. Ghandi, S. Kecman, P. W. Percival, Physica B 326 (2003) 76). This assignment is incorrect since the muon and {sup 14}N hyperfine-coupling constants (hfcc) of this radical would have the opposite sign, which is in conflict with the experimental results. The radical is now reassigned as the muoniated N-tert-butylcarbamoyl radical, based on the similarities between the experimental muon and {sup 14}N hfcc and hfcc calculated at the UB3LYP/6-311G(d,p)//UB3LYP/EPR-III level. The large zero-point energy in the N-Mu bond results in the dissociation barrier of the muoniated N-tert-butylcarbamoyl radical being above the combined energy of the reactants, in contrast to the N-tert-butylcarbamoyl radical where the dissociation barrier lies below the combined energy of the reactants. The reaction of muonium with tert-butylisothiocyanate produced both conformers of the muoniated N-tert-butylthiocarbamoyl radical and their assignment was based on the similarities between the experimental and calculated muon hfcc. These are the first acyl and thioacyl radicals to be directly detected by muon spin spectroscopy.

  15. Initial experience with ketamine-based analgesia in patients undergoing robotic radical cystectomy and diversion.

    Science.gov (United States)

    Jacobsohn, Kenneth; Davis, Tanya D; El-Arabi, Ahmad M; Tlachac, Jonathan; Langenstroer, Peter; O'Connor, R Corey; Guralnick, Michael L; See, William A; Schlosser, Robert

    2015-01-01

    We instituted a ketamine-predominant analgesic regimen in the peri- and postoperative periods to limit the effects of narcotic analgesia on bowel function in patients undergoing radical cystectomy. The primary end points of interest were time to return of bowel function, time to discharge, and efficacy of the analgesic regimen. We performed a retrospective chart review of patients undergoing robotic-assisted laparoscopic cystectomy (RARC) with urinary diversion by a single surgeon at our institution from January 1, 2011 to June 30, 2012. Patients receiving the opioid-minimizing ketamine protocol were compared to a cohort of patients undergoing RARC with an opioid-predominant analgesic regimen. In total, 15 patients (Group A) were included in the ketamine-predominant regimen and 25 patients (Group B) in the opioid-predominant control group. Three patients (19%) in Group A discontinued the protocol due to ketamine side effects. The mean time to bowel movement and length of stay in Group A versus Group B was 3 versus 6 days (p return of bowel function and length of hospitalization after RARC. Our study has its limitations as a retrospective, single surgeon, single institution study and the non-randomization of patients. Notwithstanding these limitations, this study was not designed to show inferiority of one approach, but instead to show that our protocol is safe and efficacious, warranting further study in a prospective fashion.

  16. Radical reactions in vivo - an overview

    International Nuclear Information System (INIS)

    Saran, M.; Bors, W.

    1990-01-01

    Generation of radicals in vivo depends on metabolic activities. The reactions are usually influenced by (i) the presence and concentration of oxygen, (ii) the availability of transition metals (effects of binding and compartimentalization), (iii) the level of reductants and antioxidants (e.g. nutritional effects). The effects of radicals are thought to be due to (i) membrane damage (affecting passive or active transport through altered fluidity/function interrelationships, intercellular messenging through modifications in the synthesis of prostaglandins and leukotrienes); (ii) protein damage (e.g. affecting membrane transporters, channel proteins, receptor or regulatory proteins, immunomodulators); (iii) damage to DNA. Defense mechanisms consist of (i) prevention of the 'spreading' of primary damage by low molecular weight antioxidants (e.g. vitamin E, GSH, vitamin C, β-carotene, uric acid); (ii) prevention or limitation of 'secondary' damage by enzymes (e.g. GSH-peroxidase, catalase, superoxide dismutase, DT-diaphorase) and/or chelators; (iii) repair processes, e.g. lipid degradation/membrane repair enzymes (phospholipases, peroxidases, some transferases and reductases), protein disposal or repair enzymes (proteases, GSSG-reductase), DNA degradation or repair enzymes (exonucleases III, endonucleases III and IV, glycosylases, polymerases). Recent hypotheses on a messenging function of the superoxide anion O 2 - are discussed and possible implications of cross-reactions between O 2 - and nitric oxide (endothelium-derived relaxing factor EDRF) are shortly mentioned. (orig.)

  17. The impact of robotic surgery in urology.

    Science.gov (United States)

    Giedelman, C A; Abdul-Muhsin, H; Schatloff, O; Palmer, K; Lee, L; Sanchez-Salas, R; Cathelineau, X; Dávila, H; Cavelier, L; Rueda, M; Patel, V

    2013-01-01

    More than a decade ago, robotic surgery was introduced into urology. Since then, the urological community started to look at surgery from a different angle. The present, the future hopes, and the way we looked at our past experience have all changed. Between 2000 and 2011, the published literature was reviewed using the National Library of Medicine database and the following key words: robotic surgery, robot-assisted, and radical prostatectomy. Special emphasis was given to the impact of the robotic surgery in urology. We analyzed the most representative series (finished learning curve) in each one of the robotic approaches regarding perioperative morbidity and oncological outcomes. This article looks into the impact of robotics in urology, starting from its background applications before urology, the way it was introduced into urology, its first steps, current status, and future expectations. By narrating this journey, we tried to highlight important modifications that helped robotic surgery make its way to its position today. We looked as well into the dramatic changes that robotic surgery introduced to the field of surgical training and its consequence on its learning curve. Basic surgical principles still apply in Robotics: experience counts, and prolonged practice provides knowledge and skills. In this way, the potential advantages delivered by technology will be better exploited, and this will be reflected in better outcomes for patients. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.

  18. Temporal logic motion planning in robotics

    CSIR Research Space (South Africa)

    Seotsanyana, M

    2012-08-01

    Full Text Available ) transport-related applications such as intra-logistics, automated parking garages and autonomous vehicles: (ii) mining-related applications such as automated mine vehicles and mine sensing; (iii) defence force-related applications such as autonomous... vehicles and (iv) hospital-related applications such as surgical procedures. In such applications, any failure of a robotic system may result in more than just a mere inconvenience, such as incorrect information by a robotic receptionist, loss of time...

  19. Insertion of molecular oxygen into a palladium(II) methyl bond: a radical chain mechanism involving palladium(III) intermediates.

    Science.gov (United States)

    Boisvert, Luc; Denney, Melanie C; Hanson, Susan Kloek; Goldberg, Karen I

    2009-11-04

    The reaction of (bipy)PdMe(2) (1) (bipy = 2,2'-bipyridine) with molecular oxygen results in the formation of the palladium(II) methylperoxide complex (bipy)PdMe(OOMe) (2). The identity of the product 2 has been confirmed by independent synthesis. Results of kinetic studies of this unprecedented oxygen insertion reaction into a palladium alkyl bond support the involvement of a radical chain mechanism. Reproducible rates, attained in the presence of the radical initiator 2,2'-azobis(2-methylpropionitrile) (AIBN), reveal that the reaction is overall first-order (one-half-order in both [1] and [AIBN], and zero-order in [O(2)]). The unusual rate law (half-order in [1]) implies that the reaction proceeds by a mechanism that differs significantly from those for organic autoxidations and for the recently reported examples of insertion of O(2) into Pd(II) hydride bonds. The mechanism for the autoxidation of 1 is more closely related to that found for the autoxidation of main group and early transition metal alkyl complexes. Notably, the chain propagation is proposed to proceed via a stepwise associative homolytic substitution at the Pd center of 1 with formation of a pentacoordinate Pd(III) intermediate.

  20. Utilizing Machine Learning and Automated Performance Metrics to Evaluate Robot-Assisted Radical Prostatectomy Performance and Predict Outcomes.

    Science.gov (United States)

    Hung, Andrew J; Chen, Jian; Che, Zhengping; Nilanon, Tanachat; Jarc, Anthony; Titus, Micha; Oh, Paul J; Gill, Inderbir S; Liu, Yan

    2018-05-01

    Surgical performance is critical for clinical outcomes. We present a novel machine learning (ML) method of processing automated performance metrics (APMs) to evaluate surgical performance and predict clinical outcomes after robot-assisted radical prostatectomy (RARP). We trained three ML algorithms utilizing APMs directly from robot system data (training material) and hospital length of stay (LOS; training label) (≤2 days and >2 days) from 78 RARP cases, and selected the algorithm with the best performance. The selected algorithm categorized the cases as "Predicted as expected LOS (pExp-LOS)" and "Predicted as extended LOS (pExt-LOS)." We compared postoperative outcomes of the two groups (Kruskal-Wallis/Fisher's exact tests). The algorithm then predicted individual clinical outcomes, which we compared with actual outcomes (Spearman's correlation/Fisher's exact tests). Finally, we identified five most relevant APMs adopted by the algorithm during predicting. The "Random Forest-50" (RF-50) algorithm had the best performance, reaching 87.2% accuracy in predicting LOS (73 cases as "pExp-LOS" and 5 cases as "pExt-LOS"). The "pExp-LOS" cases outperformed the "pExt-LOS" cases in surgery time (3.7 hours vs 4.6 hours, p = 0.007), LOS (2 days vs 4 days, p = 0.02), and Foley duration (9 days vs 14 days, p = 0.02). Patient outcomes predicted by the algorithm had significant association with the "ground truth" in surgery time (p algorithm in predicting, were largely related to camera manipulation. To our knowledge, ours is the first study to show that APMs and ML algorithms may help assess surgical RARP performance and predict clinical outcomes. With further accrual of clinical data (oncologic and functional data), this process will become increasingly relevant and valuable in surgical assessment and training.

  1. [Organisation and early outcome after radical prostatectomy in Denmark 2004-2007

    DEFF Research Database (Denmark)

    Borre, M.; Iversen, P.; Bendixen, A.

    2008-01-01

    .2%. CONCLUSION: There is an increasing rate of radical prostatectomies in Denmark. It is proposed that a national database be established to monitor early and long-term outcomes, including the role of surgical technique (nerve sparing, laparoscopic/robotic surgery, etc.) in order to ensure optimal organisation...

  2. The Incidence and Anatomy of Accessory Pudendal Arteries as Depicted on Multidetector-Row CT Angiography: Clinical Implications of Preoperative Evaluation for Laparoscopic and Robot-Assisted Radical Prostatectomy

    International Nuclear Information System (INIS)

    Park, Beom Jin; Sung, Deuk Jae; Kim, Min Ju; Cho, Sung Bum; Kim, Yun Hwan; Chung, Kyoo Byung; Kang, Seok Ho; Cheon, Jun

    2009-01-01

    To help preserve accessory pudendal arteries (APAs) and to ensure optimal postoperative sexual function after a laparoscopic or robot-assisted radical prostatectomy, we have evaluated the incidence of APAs as detected on multidetector-row CT (MDCT) angiography and have provided a detailed anatomical description. The distribution of APAs was evaluated in 121 consecutive male patients between February 2006 and July 2007 who underwent 64- channel MDCT angiography of the lower extremities. We defined an APA as any artery located within the periprostatic region running parallel to the dorsal vascular complex. We also subclassified APAs into lateral and apical APAs. Two radiologists retrospectively evaluated the origin, course and number of APAs; the final APA subclassification based on MDCT angiography source data was determined by consensus. We identified 44 APAs in 36 of 121 patients (30%). Two distinct varieties of APAs were identified. Thirty-three APAs (75%) coursed near the anterolateral region of the prostatic apex, termed apical APAs. The remaining 11 APAs (25%) coursed along the lateral aspect of the prostate, termed lateral APAs. All APAs originated from the internal obturator artery and iliac artery or a branch of the iliac artery such as the inferior vesical artery. The majority of apical APAs arose from the internal obturator artery (84%). Seven patients (19%) had multiple APAs. APAs are more frequently detected by the use of MDCT angiography than as suggested by previous surgical studies. The identification of APAs on MDCT angiography may provide useful information for the surgical preservation of APAs during a laparoscopic or robot-assisted radical prostatectomy

  3. Mechatronic systems and materials III

    CERN Document Server

    Gosiewski, Zdzislaw

    2009-01-01

    This very interesting volume is divided into 24 sections; each of which covers, in detail, one aspect of the subject-matter: I. Industrial robots; II. Microrobotics; III. Mobile robots; IV. Teleoperation, telerobotics, teleoperated semi-autonomous systems; V. Sensors and actuators in mechatronics; VI. Control of mechatronic systems; VII. Analysis of vibration and deformation; VIII. Optimization, optimal design; IX. Integrated diagnostics; X. Failure analysis; XI. Tribology in mechatronic systems; XII. Analysis of signals; XIII. Measurement techniques; XIV. Multifunctional and smart materials;

  4. [Comparison of robotic surgery documentary in gynecological cancer].

    Science.gov (United States)

    Vargas-Hernández, Víctor Manuel

    2012-01-01

    Robotic surgery is a surgical technique recently introduced, with major expansion and acceptance among the medical community is currently performed in over 1,000 hospitals around the world and in the management of gynecological cancer are being developed comprehensive programs for implementation. The objectives of this paper are to review the scientific literature on robotic surgery and its application in gynecological cancer to verify its safety, feasibility and efficacy when compared with laparoscopic surgery or surgery classical major surgical complications, infections are more common in traditional radical surgery compared with laparoscopic or robotic surgery and with these new techniques surgical and staying hospital are lesser than the former however, the disadvantages are the limited number of robot systems, their high cost and applies only in specialized centers that have with equipment and skilled surgeons. In conclusion robotic surgery represents a major scientific breakthrough and surgical management of gynecological cancer with better results to other types of conventional surgery and is likely in the coming years is become its worldwide.

  5. Diffusion of robotics into clinical practice in the United States: process, patient safety, learning curves, and the public health.

    Science.gov (United States)

    Mirheydar, Hossein S; Parsons, J Kellogg

    2013-06-01

    Robotic technology disseminated into urological practice without robust comparative effectiveness data. To review the diffusion of robotic surgery into urological practice. We performed a comprehensive literature review focusing on diffusion patterns, patient safety, learning curves, and comparative costs for robotic radical prostatectomy, partial nephrectomy, and radical cystectomy. Robotic urologic surgery diffused in patterns typical of novel technology spreading among practicing surgeons. Robust evidence-based data comparing outcomes of robotic to open surgery were sparse. Although initial Level 3 evidence for robotic prostatectomy observed complication outcomes similar to open prostatectomy, subsequent population-based Level 2 evidence noted an increased prevalence of adverse patient safety events and genitourinary complications among robotic patients during the early years of diffusion. Level 2 evidence indicated comparable to improved patient safety outcomes for robotic compared to open partial nephrectomy and cystectomy. Learning curve recommendations for robotic urologic surgery have drawn exclusively on Level 4 evidence and subjective, non-validated metrics. The minimum number of cases required to achieve competency for robotic prostatectomy has increased to unrealistically high levels. Most comparative cost-analyses have demonstrated that robotic surgery is significantly more expensive than open or laparoscopic surgery. Evidence-based data are limited but suggest an increased prevalence of adverse patient safety events for robotic prostatectomy early in the national diffusion period. Learning curves for robotic urologic surgery are subjective and based on non-validated metrics. The urological community should develop rigorous, evidence-based processes by which future technological innovations may diffuse in an organized and safe manner.

  6. Robotic Assisted Radical Cystectomy with Extracorporeal Urinary Diversion Does Not Show a Benefit over Open Radical Cystectomy: A Systematic Review and Meta-Analysis of Randomised Controlled Trials.

    Directory of Open Access Journals (Sweden)

    Wei Shen Tan

    Full Text Available The number of robotic assisted radical cystectomy (RARC procedures is increasing despite the lack of Level I evidence showing any advantages over open radical cystectomy (ORC. However, several systematic reviews with meta-analyses including non-randomised studies, suggest an overall benefit for RARC compared to ORC. We performed a systematic review with meta-analysis of randomised controlled trials (RCTs to evaluate the perioperative morbidity and efficacy of RARC compared to ORC in patients with bladder cancer.Literature searches of Medline/Pubmed, Embase, Web of Science and clinicaltrials.gov databases up to 10th March 2016 were performed. The inclusion criteria for eligible studies were RCTs which compared perioperative outcomes of ORC and RARC for bladder cancer. Primary objective was perioperative and histopathological outcomes of RARC versus ORC while the secondary objective was quality of life assessment (QoL, oncological outcomes and cost analysis.Four RCTs (from 5 articles met the inclusion criteria, with a total of 239 patients all with extracorporeal urinary diversion. Patient demographics and clinical characteristics of RARC and ORC patients were evenly matched. There was no significant difference between groups in perioperative morbidity, length of stay, positive surgical margin, lymph node yield and positive lymph node status. RARC group had significantly lower estimated blood loss (p<0.001 and wound complications (p = 0.03 but required significantly longer operating time (p<0.001. QoL was not measured uniformly across trials and cost analysis was reported in one RCTs. A test for heterogeneity did highlight differences across operating time of trials suggesting that surgeon experience may influence outcomes.This study does not provide evidence to support a benefit for RARC compared to ORC. These results may not have inference for RARC with intracorporeal urinary diversion. Well-designed trials with appropriate endpoints conducted

  7. Robotic-assisted laparoscopic surgery: recent advances in urology.

    Science.gov (United States)

    Autorino, Riccardo; Zargar, Homayoun; Kaouk, Jihad H

    2014-10-01

    The aim of the present review is to summarize recent developments in the field of urologic robotic surgery. A nonsystematic literature review was performed to retrieve publications related to robotic surgery in urology and evidence-based critical analysis was conducted by focusing on the literature of the past 5 years. The use of the da Vinci Surgical System, a robotic surgical system, has been implemented for the entire spectrum of extirpative and reconstructive laparoscopic kidney procedures. The robotic approach can be applied for a range of adrenal indications as well as for ureteral diseases, including benign and malignant conditions affecting the proximal, mid, and distal ureter. Current evidence suggests that robotic prostatectomy is associated with less blood loss compared with the open surgery. Besides prostate cancer, robotics has been used for simple prostatectomy in patients with symptomatic benign prostatic hyperplasia. Recent studies suggest that minimally invasive radical cystectomy provides encouraging oncologic outcomes mirroring those reported for open surgery. In recent years, the evolution of robotic surgery has enabled urologic surgeons to perform urinary diversions intracorporeally. Robotic vasectomy reversal and several other robotic andrological applications are being explored. In summary, robotic-assisted surgery is an emerging and safe technology for most urologic operations. The acceptance of robotic prostatectomy during the past decade has paved the way for urologists to explore the entire spectrum of extirpative and reconstructive urologic procedures. Cost remains a significant issue that could be solved by wider dissemination of the technology. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Impact of posterior rhabdosphincter reconstruction during robot-assisted radical prostatectomy: retrospective analysis of time to continence.

    Science.gov (United States)

    Woo, Jason R; Shikanov, Sergey; Zorn, Kevin C; Shalhav, Arieh L; Zagaja, Gregory P

    2009-12-01

    Posterior rhabdosphincter (PR) reconstruction during robot-assisted radical prostatectomy (RARP) was introduced in an attempt to improve postoperative continence. In the present study, we evaluate time to achieve continence in patients who are undergoing RARP with and without PR reconstruction. A prospective RARP database was searched for most recent cases that were accomplished with PR reconstruction (group 1, n = 69) or with standard technique (group 2, n = 63). We performed the analysis applying two definitions of continence: 0 pads per day or 0-1 security pad per day. Patients were evaluated by telephone interview. Statistical analysis was carried out using the Kaplan-Meier method and log-rank test. With PR reconstruction, continence was improved when defined as 0-1 security pad per day (median time of 90 vs 150 days; P = 0.01). This difference did not achieve statistical significance when continence was defined as 0 pads per day (P = 0.12). A statistically significant improvement in continence rate and time to achieve continence is seen in patients who are undergoing PR reconstruction during RARP, with continence defined as 0-1 security/safety pad per day. A larger, prospective and randomized study is needed to better understand the impact of this technique on postoperative continence.

  9. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    Science.gov (United States)

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets

  10. The role of intraoperative ultrasound in small renal mass robotic enucleation

    OpenAIRE

    Roberta Gunelli; Massimo Fiori; Cristiano Salaris; Umberto Salomone; Marco Urbinati; Alexia Vici; Teo Zenico; Mauro Bertocco

    2016-01-01

    Introduction: As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exo...

  11. A trinuclear radical-bridged lanthanide single-molecule magnet

    Energy Technology Data Exchange (ETDEWEB)

    Gould, Colin A.; Darago, Lucy E.; Gonzalez, Miguel I. [Department of Chemistry, University of California, Berkeley, CA (United States); Demir, Selvan [Institut fuer Anorganische Chemie, Georg-August-Universitaet, Goettingen (Germany); Long, Jeffrey R. [Department of Chemistry, University of California, Berkeley, CA (United States); Department of Chemical and Biomolecular Engineering, University of California, Berkeley, CA (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2017-08-14

    Assembly of the triangular, organic radical-bridged complexes Cp*{sub 6}Ln{sub 3}(μ{sub 3}-HAN) (Cp*=pentamethylcyclopentadienyl; Ln=Gd, Tb, Dy; HAN=hexaazatrinaphthylene) proceeds through the reaction of Cp*{sub 2}Ln(BPh{sub 4}) with HAN under strongly reducing conditions. Significantly, magnetic susceptibility measurements of these complexes support effective magnetic coupling of all three Ln{sup III} centers through the HAN{sup 3-.} radical ligand. Thorough investigation of the Dy{sup III} congener through both ac susceptibility and dc magnetic relaxation measurements reveals slow relaxation of the magnetization, with an effective thermal relaxation barrier of U{sub eff}=51 cm{sup -1}. Magnetic coupling in the Dy{sup III} complex enables a large remnant magnetization at temperatures up to 3.0 K in the magnetic hysteresis measurements and hysteresis loops that are open at zero-field up to 3.5 K. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. REGIOSELECTIVE OXIDATIONS OF EQUILENIN DERIVATIVES CATALYZED BY A RHODIUM (III) PORPHYRIN COMPLEX-CONTRAST WITH THE MANGANESE (III) PORPHYRIN. (R826653)

    Science.gov (United States)

    AbstractEquilenin acetate and dihydroequilenin acetate were oxidized with iodosobenzene and a rhodium(III) porphyrin catalyst. The selectivity of the reactions differs from that with the corresponding Mn(III) catalyst, or from that of free radical chain oxidation.

  13. Oxidation of Cu(II) aminopolycarboxylates by carbonate radical. A flash photolysis study

    International Nuclear Information System (INIS)

    Mandal, P.C.; Bardhan, D.K.

    1999-01-01

    Reactions of carbonate radical (CO 3 -. ) generated by photolysis or by radiolysis of a carbonate solution, with Cu(II) complexes of aminopolycarboxylic acids viz., Cu(II)ethylenediamine tetraacetate [Cu II EDTA] 2- and Cu(II)-iminodiacetate [Cu II IDA] were studied at pH 10.5 and ionic strength 0.2 mol x dm -3 . Time-resolved spectroscopy and kinetics for the transients were studied using flash photolysis and stable products arising from the ligand degradation of the complex were ascertained by steady-state radiolysis experiments. From the kinetic data it is observed that CO 3 -. radical reacts initially with Cu II -complex to form a transient intermediate having maximum absorption at 335 nm and 430 nm. From the subsequent reactions of this intermediate it was assigned to be Cu III .species. This Cu(III) species undergoes intermolecular electron transfer with the Cu II -complex to give a radical intermediate which again slowly reacts with Cu II -complex to give a long lived species containing Cu-C bond. This long lived species, however, slowly decomposed to give glyoxalic reaction between Cu III -complex and a suitable donor, the one electron reduction potential for [Cu III EDTA] 1- /[Cu II EDTA] 2- and [Cu III IDA] +1 /Cu II IDA was determined. (author)

  14. Laparoscopic and robotic nephroureterectomy

    DEFF Research Database (Denmark)

    Azawi, Nessn H; Berg, Kasper Drimer; Thamsborg, Andreas Key Milan

    2017-01-01

    nephroureterectomy between January 2008 and December 2014 was conducted. Outcome measures were OS and CSM. RESULTS: In total, 298 patients underwent robot-assisted or laparoscopic radical nephroureterectomy with a final histological diagnosis of UTUC. LND was performed in 46 (15.4%). One hundred and seventy...... in the selection of patients undergoing LND. CONCLUSIONS: Five-year OS and CSM are comparable between patients with N1 and N0 MID. This evidence may support the use of the LND procedure in patients with muscle-invasive UTUC....

  15. One electron oxidation of Ni(II)-iminodiacetate by carbonate radical

    International Nuclear Information System (INIS)

    Mandal, P.C.; Bardhan, D.K.; Bhattacharyya, S.N.

    1995-01-01

    Reactions of carbonate radical (CO 3 - ), generated by photolysis or by radiolysis of a carbonate solution with nickel(II)-iminodiacetate (Ni(II)IDA) were studied at pH 10.5 and ionic strength (I)=0.2 mol x dm -3 . The stable product arising from the ligand degradation in the complex is mainly glyoxalic acid. Time-resolved spectroscopy and transient kinetics were studied using flash photolysis. From the kinetic data it was suggested that the carbonate radical initially reacts with Ni(III)IDA with a rate constant (2.4.±0.4) x 10 6 dm 3 x mol -1 x s -1 to form a Ni(II)IDA species which, however, undergoes a first-order transformation (k=2.7 x 10 2 x s -1 ) to give a radical intermediate of the type Ni(II)RNHCHCO - 2 ) which rapidly forms an adduct containing a Ni-C bond. This adduct decays very slowly to give rise to glyoxalic acid. From a consideration of equilibrium between Ni(II)IDA and Ni(III)IDA, the one electron reduction potential for the Ni(III)IDA/Ni(II)IDA couple was determined to be 1.467 V. (author) 30 refs.; 5 figs

  16. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  17. [Usefullness of the Da Vinci robot in urologic surgery].

    Science.gov (United States)

    Iselin, C; Fateri, F; Caviezel, A; Schwartz, J; Hauser, J

    2007-12-05

    A telemanipulator for laparoscopic instruments is now available in the world of surgical robotics. This device has three distincts advantages over traditional laparoscopic surgery: it improves precision because of the many degrees of freedom of its instruments, and it offers 3-D vision so as better ergonomics for the surgeon. These characteristics are most useful for procedures that require delicate suturing in a focused operative field which may be difficult to reach. The Da Vinci robot has found its place in 2 domains of laparoscopic urologic surgery: radical prostatectomy and ureteral surgery. The cost of the robot, so as the price of its maintenance and instruments is high. This increases healthcare costs in comparison to open surgery, however not dramatically since patients stay less time in hospital and go back to work earlier.

  18. Does Prior Laparoscopic and Open Surgery Experience Have Any Impact on Learning Curve in Transition to Robotic Surgery?

    Directory of Open Access Journals (Sweden)

    Cüneyt Adayener

    2016-12-01

    Full Text Available It has been 15 years since the Food And Drug Administration approved the Da Vinci® robotic surgery system. Robotic applications are being used extensively in urology, particularly in radical prostatectomy. Like all high-tech products, this system also has a high cost and a steep learning curve, therefore, preventing it from becoming widespread. There are various studies on the effect of open surgery or laparoscopy experience on the learning curve of robotic surgery. Analyzing these interactions well will provide valuable information on making the training period of robotic system more efficient.

  19. A Fully Sensorized Cooperative Robotic System for Surgical Interventions

    Science.gov (United States)

    Tovar-Arriaga, Saúl; Vargas, José Emilio; Ramos, Juan M.; Aceves, Marco A.; Gorrostieta, Efren; Kalender, Willi A.

    2012-01-01

    In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms) with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms) with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms). The implemented control allows the robot to compensate for small patient movements. PMID:23012551

  20. Intramolecular electron transfer through a bridging carboxylate group coordinated to two cobalt(III)-ions

    International Nuclear Information System (INIS)

    Wieghardt, K.

    1978-01-01

    Reduction of the binuclear μ-p-nitrobenzoato -di-μ-hydroxo -bis[triammine cobalt(III)] cation with (CH 3 ) 2 COH radicals yields a radical cation with the p-nitrobenzoato radical being coordinated to two cobalt(III) ions at the carboxylic group. The unprotonated form of this species undergoes intramolecular electron transfer producing Co(II) (k = (3.3 +- 0.3). x 10 3 s -1 ). The role of the carboxylate group in the intramolecular electron transfer process is tentatively assessed in terms of an intramolecular outer-sphere reaction because of lack of overlap of the donor orbitals (π) and the acceptor orbital (sigma). The protonated form of the radical cation (pKsub(a) = 2.5) disproportionates via a bimolecular process without production of Co(II). The effect of two coordinated Co(III) ions as compared to only one on the properties of the nitrobenzoate radical anion are discussed. (orig.) 891 HK 892 GM [de

  1. Magnetic exchange in {Gd(III)-radical} complexes: method assessment, mechanism of coupling and magneto-structural correlations.

    Science.gov (United States)

    Gupta, Tulika; Rajeshkumar, Thayalan; Rajaraman, Gopalan

    2014-07-28

    Density functional studies have been performed on ten different {Gd(III)-radical} complexes exhibiting both ferro and antiferromagnetic exchange interaction with an aim to assess a suitable exchange-correlation functional within DFT formalism. This study has also been extended to probe the mechanism of magnetic coupling and to develop suitable magneto-structural correlations for this pair. Our method assessments reveal the following order of increasing accuracy for the evaluation of J values compared to experimental coupling constants: B(40HF)LYP X3LYP < B3LYP < B2PLYP. Grimme's double-hybrid functional is found to be superior compared to other functionals tested and this is followed very closely by the conventional hybrid B3LYP functional. At the basis set front, our calculations reveal that the incorporation of relativistic effect is important in these calculations and the relativistically corrected effective core potential (ECP) basis set is found to yield better Js compared to other methods. The supposedly empty 5d/6s/6p orbitals of Gd(III) are found to play an important role in the mechanism of magnetic coupling and different contributions to the exchange terms are probed using Molecular Orbital (MO) and Natural Bond Orbital (NBO) analysis. Magneto-structural correlations for Gd-O distances, Gd-O-N angles and Gd-O-N-C dihedral angles are developed where the bond angles as well as dihedral angle parameters are found to dictate the sign and strength of the magnetic coupling in this series.

  2. Building a grid-semantic map for the navigation of service robots through human–robot interaction

    Directory of Open Access Journals (Sweden)

    Cheng Zhao

    2015-11-01

    Full Text Available This paper presents an interactive approach to the construction of a grid-semantic map for the navigation of service robots in an indoor environment. It is based on the Robot Operating System (ROS framework and contains four modules, namely Interactive Module, Control Module, Navigation Module and Mapping Module. Three challenging issues have been focused during its development: (i how human voice and robot visual information could be effectively deployed in the mapping and navigation process; (ii how semantic names could combine with coordinate data in an online Grid-Semantic map; and (iii how a localization–evaluate–relocalization method could be used in global localization based on modified maximum particle weight of the particle swarm. A number of experiments are carried out in both simulated and real environments such as corridors and offices to verify its feasibility and performance.

  3. Robotic technology in surgery: current status in 2008.

    Science.gov (United States)

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  4. Radicals of DNA and DNA nucleotides generated by ionising radiation

    International Nuclear Information System (INIS)

    Przybytniak, G.

    2004-01-01

    A first stage of cell processes leading to DNA damage of initiated by radical reactions. In a model system such transformations were generated by ionising radiation which involves production of electron loss and electron gain centers of the substrate and radical formation. Using cryogenic ESR spectroscopy it was found that the DNA nucleotides, which convert to radical anions upon electron capture undergo the separation of unpaired spin and charge due to protonation. Circular and linear dichroism studies enabled to conclude that iron ions(III) induce strong changes in the DNA helical structure indicating their coordination with nitrogen bases. The repair of DNA radicals produced via radiolytic oxidation, i.e. the guanine radical cation and the allyl type radical of thymine, is possible at elevated temperatures due to the involvement of sulphydryl groups. The influence of the thiol charge is then limited

  5. Attitudinal Change in Elderly Citizens Toward Social Robots: The Role of Personality Traits and Beliefs About Robot Functionality.

    Science.gov (United States)

    Damholdt, Malene F; Nørskov, Marco; Yamazaki, Ryuji; Hakli, Raul; Hansen, Catharina Vesterager; Vestergaard, Christina; Seibt, Johanna

    2015-01-01

    Attitudes toward robots influence the tendency to accept or reject robotic devices. Thus it is important to investigate whether and how attitudes toward robots can change. In this pilot study we investigate attitudinal changes in elderly citizens toward a tele-operated robot in relation to three parameters: (i) the information provided about robot functionality, (ii) the number of encounters, (iii) personality type. Fourteen elderly residents at a rehabilitation center participated. Pre-encounter attitudes toward robots, anthropomorphic thinking, and personality were assessed. Thereafter the participants interacted with a tele-operated robot (Telenoid) during their lunch (c. 30 min.) for up to 3 days. Half of the participants were informed that the robot was tele-operated (IC) whilst the other half were naïve to its functioning (UC). Post-encounter assessments of attitudes toward robots and anthropomorphic thinking were undertaken to assess change. Attitudes toward robots were assessed with a new generic 35-items questionnaire (attitudes toward social robots scale: ASOR-5), offering a differentiated conceptualization of the conditions for social interaction. There was no significant difference between the IC and UC groups in attitude change toward robots though trends were observed. Personality was correlated with some tendencies for attitude changes; Extraversion correlated with positive attitude changes to intimate-personal relatedness with the robot (r = 0.619) and to psychological relatedness (r = 0.581) whilst Neuroticism correlated negatively (r = -0.582) with mental relatedness with the robot. The results tentatively suggest that neither information about functionality nor direct repeated encounters are pivotal in changing attitudes toward robots in elderly citizens. This may reflect a cognitive congruence bias where the robot is experienced in congruence with initial attitudes, or it may support action-based explanations of cognitive dissonance reductions

  6. Attitudinal change in elderly citizens towards social robots: the role of personality traits and beliefs about robot functionality.

    Directory of Open Access Journals (Sweden)

    Malene Flensborg Damholdt

    2015-11-01

    Full Text Available Attitudes towards robots influence the tendency to accept or reject robotic devices. Thus it is important to investigate whether and how attitudes towards robots can change. In this pilot study we investigate attitudinal changes in elderly citizens toward a tele-operated robot in relation to three parameters: (i the information provided about robot functionality, (ii the number of encounters, (iii personality type. Fourteen elderly residents at a rehabilitation centre participated. Pre-encounter attitudes towards robots, anthropomorphic thinking, and personality were assessed. Thereafter the participants interacted with a tele-operated robot (Telenoid during their lunch (c. 30 min. for up to three days. Half of the participants were informed that the robot was tele-operated (IC whilst the other half were naïve to its functioning (UC. Post-encounter assessments of attitudes towards robots and anthropomorphic thinking were undertaken to assess change. Attitudes towards robots were assessed with a new generic 35-item questionnaire (Attitudes towards social robots scale: ASOR-5, offering a differentiated conceptualization of the conditions for social interaction.There was no significant difference between the IC and UC groups in attitude change towards robots though trends were observed. Personality was correlated with some tendencies for attitude changes; Extraversion correlated with positive attitude changes to intimate-personal relatedness with the robot (r=.619 and to psychological relatedness (r=.581 whilst Neuroticism correlated negatively (r=-.582 with mental relatedness with the robot. The results tentatively suggest that neither information about functionality nor direct repeated encounters are pivotal in changing attitudes towards robots in elderly citizens. This may reflect a cognitive congruence bias where the robot is experienced in congruence with initial attitudes, or it may support action-based explanations of cognitive dissonance

  7. Free-radical coupling, cleavage, and redox reactions in 60Co γ radiolysis of aqueous methyl acetate. Effects of additives

    International Nuclear Information System (INIS)

    Bernath, T.; Parsons, G.H. Jr.; Cohen, S.G.

    1975-01-01

    Reaction of methyl acetate with e - /sub aq/ may lead to CH 3 C(O )OCH 3 (I - ), CH 3 C(OH)OCH 3 (II), and CH 3 CO (IIA), and with .OH and H. to .CH 2 CO 2 CH 3 (III), and to CH 3 CO 2 CH 2 . (IV). Methyl acetate is consumed, G = --3.5, and the loss is decreased by formate which scavenges .H and .OH, and increased by N 2 O which converts e - /sub aq/ to .OH. Hydrogen is formed, G = 1.1, and this is decreased by scavengers for H., and increased by H + which converts e - /sub aq/ to H.. In radiolysis of 0.027 M methyl acetate, 1.5 x 10 22 ev/l., radical combination products are: ethylene diacetate (CH 3 CO 2 CH 2 CH 2 OCOCH 3 ) (EDA), G = 0.48, from IV + IV; methyl β-acetoxypropionate (CH 3 CO 2 CH 2 CH 2 CO 2 CH 3 ) (MAP), G = 0.28, from IV + III; dimethyl succinate (DMS), G = 0.05, from III + III; and a mixture of methyl acetoacetate and acetonyl acetate (MAA and AA), (MAS and AA), G = 0.07. Biacetyl is not observed. β-Mercaptopropionic acid, 0.0005 M, prevents formation of coupling products, as it reduces radicals III and IV, and thiyl radical oxidizes radical II back to methyl acetate. Other sources of .OH, Fenton's reagent and H 2 O 2 -uv, lead to EDA, MAP, and DMS with a high IV/III ratio. H. preferentially attacks acyl C--H; .OH preferentially attacks alkoxyl C--H. Yields of radicals involved in formation of coupling products and acetic acid are estimated: G(II and IIA) = 1.2; G(III) = 1.4; G(IV) = 1.7. Part of the radicals, G approximately 1.6, regenerate methyl acetate by self-repair reduction of IV and III by II. Deuterium is introduced into methyl acetate during radiolysis in D 2 O. (U.S.)

  8. Complications of Radical Cystectomy and Orthotopic Reconstruction

    Directory of Open Access Journals (Sweden)

    Wei Shen Tan

    2015-01-01

    Full Text Available Radical cystectomy and orthotopic reconstruction significant morbidity and mortality despite advances in minimal invasive and robotic technology. In this review, we will discuss early and late complications, as well as describe efforts to minimize morbidity and mortality, with a focus on ileal orthotopic bladder substitute (OBS. We summarise efforts to minimize morbidity and mortality including enhanced recovery as well as early and late complications seen after radical cystectomy and OBS. Centralisation of complex cancer services in the UK has led to a fall in mortality and high volume institutions have a significantly lower rate of 30-day mortality compared to low volume institutions. Enhanced recovery pathways have resulted in shorter length of hospital stay and potentially a reduction in morbidity. Early complications of radical cystectomy occur as a direct result of the surgery itself while late complications, which can occur even after 10 years after surgery, are due to urinary diversion. OBS represents the ideal urinary diversion for patients without contraindications. However, all patients with OBS should have regular long term follow-up for oncological surveillance and to identify complications should they arise.

  9. Fe(III)-solar light induced degradation of diethyl phthalate (DEP) in aqueous solutions.

    Science.gov (United States)

    Mailhot, G; Sarakha, M; Lavedrine, B; Cáceres, J; Malato, S

    2002-11-01

    The degradation of diethyl phthalate (DEP) photoinduced by Fe(III) in aqueous solutions has been investigated under solar irradiation in the compound parabolic collector reactor at Plataforma Solar de Almeria. Hydroxyl radicals *OH, responsible of the degradation, are formed via an intramolecular photoredox process in the excited state of Fe(III) aquacomplexes. The primary step of the reaction is mainly due to the attack of *OH radicals on the aromatic ring. For prolonged irradiations DEP and its photoproducts are completely mineralized due to the regeneration of the absorbing species and the continuous formation of *OH radicals that confers a catalytic aspect to the process. Consequently, the degradation photoinduced by Fe(III) could be an efficient method of DEP removal from water.

  10. Spectroscopic and Kinetic Characterization of Peroxidase-Like π-Cation Radical Pinch-Porphyrin-Iron(III Reaction Intermediate Models of Peroxidase Enzymes

    Directory of Open Access Journals (Sweden)

    Samuel Hernández Anzaldo

    2016-06-01

    Full Text Available The spectroscopic and kinetic characterization of two intermediates from the H2O2 oxidation of three dimethyl ester [(proto, (meso, (deuteroporphyrinato (picdien]Fe(III complexes ([FePPPic], [FeMPPic] and [FeDPPic], respectively pinch-porphyrin peroxidase enzyme models, with s = 5/2 and 3/2 Fe(III quantum mixed spin (qms ground states is described herein. The kinetic study by UV/Vis at λmax = 465 nm showed two different types of kinetics during the oxidation process in the guaiacol test for peroxidases (1–3 + guaiacol + H2O2 → oxidation guaiacol products. The first intermediate was observed during the first 24 s of the reaction. When the reaction conditions were changed to higher concentration of pinch-porphyrins and hydrogen peroxide only one type of kinetics was observed. Next, the reaction was performed only between pinch-porphyrins-Fe(III and H2O2, resulting in only two types of kinetics that were developed during the first 0–4 s. After this time a self-oxidation process was observed. Our hypotheses state that the formation of the π-cation radicals, reaction intermediates of the pinch-porphyrin-Fe(III family with the ligand picdien [N,N’-bis-pyridin-2-ylmethyl-propane-1,3-diamine], occurred with unique kinetics that are different from the overall process and was involved in the oxidation pathway. UV-Vis, 1H-NMR and ESR spectra confirmed the formation of such intermediates. The results in this paper highlight the link between different spectroscopic techniques that positively depict the kinetic traits of artificial compounds with enzyme-like activity.

  11. Use of Fe(III) oxalate for oxidativewastewater treatment; Einsatz von Fe(III)-Oxalat zur chemisch-oxidativen Abwasserbehandlung

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.M.; Vogelpohl, A. [Clausthal Univ., Clausthal-Zellerfeld (Germany). Inst. fuer Thermische Verfahrenstechnik

    1998-08-01

    Iron(III)-oxalate was used as an iron catalyst for the Photo Fenton reaction. Iron(III) oxalations ([Fe(C{sub 2}O{sub 4}){sub 3}]{sup 3-}) are reduced to Fe(II) by irradiation using near UV-light ({lambda} = 300 - 400 nm) or visible light ({lambda} > 400 nm). At the same time, CO{sub 2}{sup -} or C{sub 2}O{sub 4}{sup -}-radicals originate, which cause the secondary reduction of Fe(III) to Fe(II). By means of the photolytically regenerated Fe(II) ions, hydroxyl radicals are increasingly formed, so that the degradation of organic substances is accelerated. The work aimed to assess the catalytic effect of Fe(III) oxalate for photochemical oxidation processes and to establish the parameters influencing further treatment of leachate from a municipal waste sanitary landfill by means of technical-scale experiments. (orig.) [Deutsch] In der vorliegenden Arbeit wurde Eisen(III)-Oxalat als Eisenkatalysator fuer die Photo-Fenton-Reaktion eingesetzt. Eisen(III)-Oxalationen ([Fe(C{sub 2}O{sub 4}){sub 3}]{sup 3-}) werden durch Strahlung mit nahem UV-Licht ({lambda}=300 bis 400 nm) oder mit sichtbarem Licht ({lambda}>400 nm) zu Fe(II) reduziert. Gleichzeitig entstehen CO{sub 2}{sup .-} oder C{sub 2}O{sub 4}{sup .-}-Radikale, die eine sekundaere Reduktion von Fe(III) zu Fe(II) bewirken. Mit Hilfe der photolytiisch regenerierten Fe(II)-Ionen werden vermehrt Hydroxylradikale gebildet und damit die Abbaugeschwindigkeit der organischen Substanzen beschleunigt. Ziel der hier vorgestellten Arbeit war es, die katalytische Wirkung von Fe(III)-Oxalat fuer photochemische Oxidationsverfahren abzuschaetzen und die Einflussparameter zur weitergehenden Behandlung eines Deponiesickerwassers aus Hausmuelldeponie anhand von Technikumsversuchen zu ermitteln. (orig.)

  12. Comparing robotic, laparoscopic and open cystectomy: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Thomas Fonseka

    2015-03-01

    Full Text Available Objective: To conduct a systematic review and meta-analysis comparing outcomes between Open Radical Cystectomy (ORC, Laparoscopic Radical Cystectomy (LRC and Robot-assisted Radical Cystectomy (RARC. RARC is to be compared to LRC and ORC and LRC compared to ORC. Material and methods: A systematic review of the literature was conducted, collating studies comparing RARC, LRC and ORC. Surgical and oncological outcome data were extracted and a meta-analysis was performed. Results: Twenty-four studies were selected with total of 2,104 cases analyzed. RARC had a longer operative time (OPT compared to LRC with no statistical difference between length of stay (LOS and estimated blood loss (EBL. RARC had a significantly shorter LOS, reduced EBL, lower complication rate and longer OPT compared to ORC. There were no significant differences regarding lymph node yield (LNY and positive surgical margins (PSM. LRC had a reduced EBL, shorter LOS and increased OPT compared to ORC. There was no significant difference regarding LNY. Conclusion: RARC is comparable to LRC with better surgical results than ORC. LRC has better surgical outcomes than ORC. With the unique technological features of the robotic surgical system and increasing trend of intra-corporeal reconstruction it is likely that RARC will become the surgical option of choice.

  13. Adriamycin and derivatives interaction with the mitochondrial membrane: O2 consumption and free radicals formation

    NARCIS (Netherlands)

    Pollakis, G.; Goormaghtigh, E.; Delmelle, M.; Lion, Y.; Ruysschaert, J. M.

    1984-01-01

    Adriamycin induces the formation of semiquinone free radicals, O(2) and OH. species, in beef heart intact mitochondria, submitochondrial particles and complex I-III containing proteoliposomes. Free radicals were detected by the use of Electron Spin Resonance (ESR) spectroscopy with the spin trapping

  14. Robotic surgery in Italy national survey (2011).

    Science.gov (United States)

    Santoro, Eugenio; Pansadoro, Vito

    2013-03-01

    Robotic surgery in Italy has become a clinical reality that is gaining increasing acceptance. As of 2011 after the United States, Italy together with Germany is the country with the largest number of active Robotic centers, 46, and da Vinci Robots installed, with at least 116 operators already trained. The number of interventions performed in Italy in 2011 exceeded 6,000 and in 2010 were 4,784, with prevalence for urology, general surgery and gynecology, however these interventions have also begun to be applied in other fields such as cervicofacial, cardiothoracic and pediatric surgery. In Italy Robotic centers are mostly located in Northern Italy, while in the South there are only a few centers, and four regions are lacking altogether. Of the 46 centers which were started in 1999, the vast majority is still operational and almost half handle over 200 cases a year. The quality of the work is also especially high with large diffusion of radical prostatectomy in urology and liver resection and colic in general surgery. The method is very well accepted among operators, over 80 %, and among patients, over 95 %. From the analysis of world literature and a survey carried out in Italy, Robotic surgery, which at the moment could be better defined as telesurgery, represents a significant advantage for operators and a consistent gain for the patient. However, it still has important limits such as high cost and non-structured training of operators.

  15. Kinetics and mechanisms of the reactions of alkyl radicals with oxygen and with complexes of Co(III), Ru(III), and Ni(III)

    International Nuclear Information System (INIS)

    Kelley, D.

    1990-01-01

    The kinetics of the reactions of C 2 H 5 radical with Co(NH 3 ) 5 X 2+ , Ru(NH 3 ) 5 X 2+ , and Co(dmgH) 2 (X) (Y) (X = Br, Cl, N 3 , SCN; Y = H 2 O, CH 3 CN) complexes were studied using laser flash photolysis of ethylcobalt complexes. The kinetics were obtained by the kinetic probe method. Some relative rate constants were also determined by a competition method based on ethyl halide product ratios. The kinetics of colligation reactions of a series of alkyl radicals with β-Ni(cyclam) 2+ were studied using flaser flash photolysis of alkylcobalt complexes. Again, the kinetics were obtained by employing the kinetic probe competition method. The kinetics of the unimolecular homolysis of a series of RNi(cyclam)H 2 O 2+ were studied. Activation parameters were obtained for the unimolecular homolysis of C 2 H 5 Ni(cyclam)H 2 O 2+ . Kinetic and thermodynamic data obtained from these reactions were compared with those for the σ-bonded organometallic complexes. The kinetics of the unimolecular homolysis of a series of RNi(cyclam)H 2 O 2+ complexes were studied by monitoring the formation of the oxygen insertion product RO 2 Ni(cyclam)H 2 O 2+ . The higher rate constants for the reactions of alkyl radicals with oxygen in solution, as compared with those measured in the gas phase, were discussed. 30 refs

  16. Studies of a nitroxide radical by EPR in monocrystal: interaction of protons and electronic relaxation

    International Nuclear Information System (INIS)

    Alonso, A.

    1986-01-01

    The ESR spectra of a nitroxide radical, 4-hydroxi-2,2,6,6-tetramethylpiperidine-1-oxyl (TANOL II), introduced as impurity in a diamagnetic host, 4-hydroxi-2,6,6-tetramethylpiperedine (I), were investigated. The use of deuterated radical, 4-hydroxi-2,2,6,6 tetramethylpiperidine-d sub(17) -1, oxyl (PD-TANOL, III) improved the resolution of ESR spectra for most of orientations of magnetic field. The proton interqactions in the neighbourhood of magnetic group N-O were studied and superpyresfine tensors for two strongly coupled protons were determined. In order to study the influence of protons on electronic relaxation of radicals, the relaxation times T sub(1) and T sub(2) were estimated in the temperature range-160 sup(0)C - 25 sup(0)C for several orientations, and comparing data for protonated and deuterated radicals II and III, using the continuous wave saturation method. (author)

  17. Multi-robot Task Allocation for Search and Rescue Missions

    International Nuclear Information System (INIS)

    Hussein, Ahmed; Adel, Mohamed; Bakr, Mohamed; Shehata, Omar M; Khamis, Alaa

    2014-01-01

    Many researchers from academia and industry are attracted to investigate how to design and develop robust versatile multi-robot systems by solving a number of challenging and complex problems such as task allocation, group formation, self-organization and much more. In this study, the problem of multi-robot task allocation (MRTA) is tackled. MRTA is the problem of optimally allocating a set of tasks to a group of robots to optimize the overall system performance while being subjected to a set of constraints. A generic market-based approach is proposed in this paper to solve this problem. The efficacy of the proposed approach is quantitatively evaluated through simulation and real experimentation using heterogeneous Khepera-III mobile robots. The results from both simulation and experimentation indicate the high performance of the proposed algorithms and their applicability in search and rescue missions

  18. Combined robotic transanal total mesorectal excision (R-taTME) and single-site plus one-port (R-SSPO) technique for ultra-low rectal surgery-initial experience with a new operation approach.

    Science.gov (United States)

    Kuo, Li-Jen; Ngu, James Chi-Yong; Tong, Yiu-Shun; Chen, Chia-Che

    2017-02-01

    Robot-assisted rectal surgery is gaining popularity, and robotic single-site surgery is also being explored clinically. We report our initial experience with robotic transanal total mesorectal excision (R-taTME) and radical proctectomy using the robotic single-site plus one-port (R-SSPO) technique for low rectal surgery. Between July 2015 and March 2016, 15 consecutive patients with ultra-low rectal lesions underwent R-taTME followed by radical proctectomy using the R-SSPO technique by a single surgeon. The clinical and pathological results were retrospectively analyzed. The median operative time was 473 (range, 335-569) min, and the estimated blood loss was 33 (range, 30-50) mL. The median number of lymph nodes harvested was 12 (range, 8-18). The median distal resection margin was 1.4 (range, 0.4-3.5) cm, and all patients had clear circumferential resection margins. We encountered a left ureteric transection intraoperatively in one patient, and another patient required reoperation for postoperative adhesive intestinal obstruction. There was no 30-day mortality. R-taTME followed by radical proctectomy using the R-SSPO technique for patients with low rectal lesions is technically feasible and safe without compromising oncologic outcomes. However, there were considerable limitations and a steep learning curve using current robotic technology.

  19. Combining the catalytic enantioselective reaction of visible-light-generated radicals with a by-product utilization system.

    Science.gov (United States)

    Huang, Xiaoqiang; Luo, Shipeng; Burghaus, Olaf; Webster, Richard D; Harms, Klaus; Meggers, Eric

    2017-10-01

    We report an unusual reaction design in which a chiral bis-cyclometalated rhodium(iii) complex enables the stereocontrolled chemistry of photo-generated carbon-centered radicals and at the same time catalyzes an enantioselective sulfonyl radical addition to an alkene. Specifically, employing inexpensive and readily available Hantzsch esters as the photoredox mediator, Rh-coordinated prochiral radicals generated by a selective photoinduced single electron reduction are trapped by allyl sulfones in a highly stereocontrolled fashion, providing radical allylation products with up to 97% ee. The hereby formed fragmented sulfonyl radicals are utilized via an enantioselective radical addition to form chiral sulfones, which minimizes waste generation.

  20. Usability assessment of ASIBOT: a portable robot to aid patients with spinal cord injury

    OpenAIRE

    Jardón Huete, Alberto; Gil, Ángel M.; Peña, Ana I. de la; Monje Micharet, Concepción Alicia; Balaguer Bernaldo de Quirós, Carlos

    2011-01-01

    The usability concept refers to aspects related to the use of products that are closely linked to the user's degree of satisfaction. Our goal is to present a functional evaluation methodology for assessing the usability of sophisticated technical aids, such as a portable robot for helping disabled patients with severe spinal cord injuries. The specific manipulator used for this task is ASIBOT, a personal assistance robot totally developed by RoboticsLab at the University Carlos III of Madrid....

  1. Robots in Elderly Care

    Directory of Open Access Journals (Sweden)

    Alessandro Vercelli

    2018-03-01

    Full Text Available Low birth rate and the long life expectancy represent an explosive mixture, resulting in the rapid aging of population. The costs of healthcare in the grey society are increasing dramatically, and soon there will be not enough resources and people for care. This context requires conceptually new elderly care solutions progressively reducing the percentages of the human-based care. Research on robot-based solutions for elderly care and active ageing aims to answer these needs. From a general perspective, robotics has the power to completely reshape the landscape of healthcare both in its structure and its operation. In fact, the long-term sustainability of healthcare systems could be addressed by automation powered by digital health technologies, such as artificial intelligence, 3D-printing or robotics. The latter could take over monotonous work from healthcare workers, which would allow them to focus more on patients and to have lesser workload. Robots might be used in elder care with several different aims. (i Robots may act as caregivers, i.e. assist the elderly, (ii they can provide remainders and instructions for activities of daily life and safety, and/or assist their carers in daily tasks; (iii they can help monitor their behaviour and health; and (iv provide companionship, including entertainment and hobbies, reminiscence and social contact. The use of Robots with human subjects/patients raise several sensitive questions. First of all, robots may represent information hubs, and can collect an incredible amount of data about the subjects and their environment. In fact, they record habits such as sleeping, exercising, third persons entering in the house, appointments. Communications may be continuously recorded. Moreover, by connecting with medical devices, they can store medical data. On one hand, this represents a very powerful tool to collect information about the single subject (precision medicine, about disease (thus eventually finding

  2. Dynamics based modeling of wheeled platform for humanoid robot torso

    Directory of Open Access Journals (Sweden)

    Petrović Vladimir M.

    2016-01-01

    Full Text Available From the ancient mythology till the modern times, people were trying to build an artificial mechanical replica of themselves. Inspired by this long tradition of various engineering projects, we will hereby describe a partly humanoid robotic structure. Our robotic configuration is composed out of an anthropomimetic upper body, but instead of legs it uses a wheeled cart for the motion. In our research, this so-called semi-anthropomimetic structure has a four-wheeled cart. This work is aiming to analyze the behaviour of the robot that is exposed to different kind of external disturbances. Disturbances coming from the outside in the form of external forces (impulse and long term simulate the interactions of the robot and its ambience. Necessary simulations were thoroughly executed (in that way analyzing robotic balance and proper size of the cart is evaluated following the ZMP theoretical background. [Projekat Ministarstva nauke Republike Srbije, br. TR-35003 i br. III-44008

  3. Disproportionation of hydroxylamine by water-soluble iron(III) porphyrinate compounds.

    Science.gov (United States)

    Bari, Sara E; Amorebieta, Valentín T; Gutiérrez, María M; Olabe, José A; Doctorovich, Fabio

    2010-01-01

    The reactions of hydroxylamine (HA) with several water-soluble iron(III) porphyrinate compounds, namely iron(III) meso-tetrakis-(N-ethylpyridinium-2yl)-porphyrinate ([Fe(III)(TEPyP)](5+)), iron(III) meso-tetrakis-(4-sulphonatophenyl)-porphyrinate ([Fe(III)(TPPS)](3-)), and microperoxidase 11 ([Fe(III)(MP11)]) were studied for different [Fe(III)(Porph)]/[HA] ratios, under anaerobic conditions at neutral pH. Efficient catalytic processes leading to the disproportionation of HA by these iron(III) porphyrinates were evidenced for the first time. As a common feature, only N(2) and N(2)O were found as gaseous, nitrogen-containing oxidation products, while NH(3) was the unique reduced species detected. Different N(2)/N(2)O ratios obtained with these three porphyrinates strongly suggest distinctive mechanistic scenarios: while [Fe(III)(TEPyP)](5+) and [Fe(III)(MP11)] formed unknown steady-state porphyrinic intermediates in the presence of HA, [Fe(III)(TPPS)](3-) led to the well characterized soluble intermediate, [Fe(II)(TPPS)NO](4-). Free-radical formation was only evidenced for [Fe(III)(TEPyP)](5+), as a consequence of a metal centered reduction. We discuss the catalytic pathways of HA disproportionation on the basis of the distribution of gaseous products, free radicals formation, the nature of porphyrinic intermediates, the Fe(II)/Fe(III) redox potential, the coordinating capabilities of each complex, and the kinetic analysis. The absence of NO(2)(-) revealed either that no HAO-like activity was operative under our reaction conditions, or that NO(2)(-), if formed, was consumed in the reaction milieu.

  4. A Bayesian Developmental Approach to Robotic Goal-Based Imitation Learning.

    Directory of Open Access Journals (Sweden)

    Michael Jae-Yoon Chung

    Full Text Available A fundamental challenge in robotics today is building robots that can learn new skills by observing humans and imitating human actions. We propose a new Bayesian approach to robotic learning by imitation inspired by the developmental hypothesis that children use self-experience to bootstrap the process of intention recognition and goal-based imitation. Our approach allows an autonomous agent to: (i learn probabilistic models of actions through self-discovery and experience, (ii utilize these learned models for inferring the goals of human actions, and (iii perform goal-based imitation for robotic learning and human-robot collaboration. Such an approach allows a robot to leverage its increasing repertoire of learned behaviors to interpret increasingly complex human actions and use the inferred goals for imitation, even when the robot has very different actuators from humans. We demonstrate our approach using two different scenarios: (i a simulated robot that learns human-like gaze following behavior, and (ii a robot that learns to imitate human actions in a tabletop organization task. In both cases, the agent learns a probabilistic model of its own actions, and uses this model for goal inference and goal-based imitation. We also show that the robotic agent can use its probabilistic model to seek human assistance when it recognizes that its inferred actions are too uncertain, risky, or impossible to perform, thereby opening the door to human-robot collaboration.

  5. Laws on Robots, Laws by Robots, Laws in Robots : Regulating Robot Behaviour by Design

    NARCIS (Netherlands)

    Leenes, R.E.; Lucivero, F.

    2015-01-01

    Speculation about robot morality is almost as old as the concept of a robot itself. Asimov’s three laws of robotics provide an early and well-discussed example of moral rules robots should observe. Despite the widespread influence of the three laws of robotics and their role in shaping visions of

  6. Advanced robotics for medical rehabilitation current state of the art and recent advances

    CERN Document Server

    Xie, Shane

    2016-01-01

    Focussing on the key technologies in developing robots for a wide range of medical rehabilitation activities – which will include robotics basics, modelling and control, biomechanics modelling, rehabilitation strategies, robot assistance, clinical setup/implementation as well as neural and muscular interfaces for rehabilitation robot control – this book is split into two parts; a review of the current state of the art, and recent advances in robotics for medical rehabilitation. Both parts will include five sections for the five key areas in rehabilitation robotics: (i) the upper limb; (ii) lower limb for gait rehabilitation (iii) hand, finger and wrist; (iv) ankle for strains and sprains; and (v) the use of EEG and EMG to create interfaces between the neurological and muscular functions of the patients and the rehabilitation robots. Each chapter provides a description of the design of the device, the control system used, and the implementation and testing to show how it fulfils the needs of that specific ...

  7. Robotics research in Chile

    Directory of Open Access Journals (Sweden)

    Javier Ruiz-del-Solar

    2016-12-01

    Full Text Available The development of research in robotics in a developing country is a challenging task. Factors such as low research funds, low trust from local companies and the government, and a small number of qualified researchers hinder the development of strong, local research groups. In this article, and as a case of study, we present our research group in robotics at the Advanced Mining Technology Center of the Universidad de Chile, and the way in which we have addressed these challenges. In 2008, we decided to focus our research efforts in mining, which is the main industry in Chile. We observed that this industry has needs in terms of safety, productivity, operational continuity, and environmental care. All these needs could be addressed with robotics and automation technology. In a first stage, we concentrate ourselves in building capabilities in field robotics, starting with the automation of a commercial vehicle. An important outcome of this project was the earn of the local mining industry confidence. Then, in a second stage started in 2012, we began working with the local mining industry in technological projects. In this article, we describe three of the technological projects that we have developed with industry support: (i an autonomous vehicle for mining environments without global positioning system coverage; (ii the inspection of the irrigation flow in heap leach piles using unmanned aerial vehicles and thermal cameras; and (iii an enhanced vision system for vehicle teleoperation in adverse climatic conditions.

  8. Cultural Robotics: The Culture of Robotics and Robotics in Culture

    Directory of Open Access Journals (Sweden)

    Hooman Samani

    2013-12-01

    Full Text Available In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. According to the importance of the embodiment of robots in the sense of presence, the influence of robots in communication culture is anticipated. The sustainability of robotics culture based on diversity for cultural communities for various acceptance modalities is explored in order to anticipate the creation of different attributes of culture between robots and humans in the future.

  9. Friendly network robotics; Friendly network robotics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This paper summarizes the research results on the friendly network robotics in fiscal 1996. This research assumes an android robot as an ultimate robot and the future robot system utilizing computer network technology. The robot aiming at human daily work activities in factories or under extreme environments is required to work under usual human work environments. The human robot with similar size, shape and functions to human being is desirable. Such robot having a head with two eyes, two ears and mouth can hold a conversation with human being, can walk with two legs by autonomous adaptive control, and has a behavior intelligence. Remote operation of such robot is also possible through high-speed computer network. As a key technology to use this robot under coexistence with human being, establishment of human coexistent robotics was studied. As network based robotics, use of robots connected with computer networks was also studied. In addition, the R-cube (R{sup 3}) plan (realtime remote control robot technology) was proposed. 82 refs., 86 figs., 12 tabs.

  10. Pulse-radiolytic investigation of the reduction of titanium(III) ions in aqueous solutions

    International Nuclear Information System (INIS)

    Micic, O.I.; Nenadovic, M.T.

    1979-01-01

    The absorption spectrum and decay kinetics of intermediates formed by the reaction of titanium(III) ions with H atoms, hydrated electrons, and carboxyl radicals have been studied in aqueous solution using the pulse-radiolysis technique. The product of the reaction with H atoms in acid solution is a Ti 3+ -H hydride intermediate which decomposes by a first-order process with a half-life of ca. 3 s. Titanium(II) is formed by reaction with hydrated electrons and CO 2 H radicals. The absorption spectrum of titanium(II) and the kinetics of its reactions are reported and discussed. The formation of molecular hydrogen by reaction of Ti 2+ with water is suppressed by the other solutes in the solutions. Titanium(III) reacts with CO 2 H, CH 2 CO 2 H, and CH(CO 2 H) 2 radicals to give titanium-radical complexes. (author)

  11. A clinical review of treatment outcomes in glioblastoma multiforme - the validation in a non-trial population of the results of a randomised Phase III clinical trial: has a more radical approach improved survival?

    LENUS (Irish Health Repository)

    Rock, K

    2012-01-03

    Objective: Glioblastoma multiforme (GBM) accounts for up to 60% of all malignant primary brain tumours in adults, occurring in 2-3 cases per 100 000 in Europe and North America. In 2005, a Phase III clinical trial demonstrated a significant improvement in survival over 2, and subsequently, 5 years with the addition of concurrent and adjuvant temozolomide (TMZ) to radical radiotherapy (RT) (Stupp R, Hegi M, van den Bent M, et al. Effects of radiotherapy with concomitant and adjuvant temozolomide versus radiotherapy alone on survival in glioblastoma in a randomised phase III study: 5-year analysis of the EORTC-NCIC trial. Lancet Oncol 2009:10:459-66). The aim of this study was to investigate if the demonstrated improved survival in the literature translated to clinical practice.Methods: This was a retrospective study including all patients with histologically proven GBM diagnosed from 1999 to 2008 and treated with adjuvant RT at our institution. A total of 273 patients were identified. Statistical analysis was carried out using SPSS v18.Results: The median survival for the whole group (n = 273) over the 10-year period was 7.6 months (95% confidence interval 6.7-8.4 months). Overall, the cumulative probability of survival at 1 and 2 years was 31.5 and 9.4%, respectively. In total, 146 patients received radical RT. 103 patients were treated with radical RT and TMZ and 43 patients received radical RT alone. The median survival for patients receiving radical RT with TMZ was 13.4 months (95% CI 10.9-15.8 months) vs 8.8 months for radical RT alone (95% CI 6.9 - 10.7 months, p = 0.006). 2-year survival figures were 21.2 vs 4.7%, respectively. On multivariate analysis, independent predictors of survival included KPS, RT dose, TMZ and extent of surgery. The strongest predictors of poorer outcome based on the hazard ratio were palliative RT, followed by not receiving TMZ chemotherapy, then KPS <90 and a biopsy only surgical approach.Conclusion: This paper demonstrates

  12. A clinical review of treatment outcomes in glioblastoma multiforme - the validation in a non-trial population of the results of a randomised Phase III clinical trial: has a more radical approach improved survival?

    LENUS (Irish Health Repository)

    2012-02-01

    Objective: Glioblastoma multiforme (GBM) accounts for up to 60% of all malignant primary brain tumours in adults, occurring in 2-3 cases per 100 000 in Europe and North America. In 2005, a Phase III clinical trial demonstrated a significant improvement in survival over 2, and subsequently, 5 years with the addition of concurrent and adjuvant temozolomide (TMZ) to radical radiotherapy (RT) (Stupp R, Hegi M, van den Bent M, et al. Effects of radiotherapy with concomitant and adjuvant temozolomide versus radiotherapy alone on survival in glioblastoma in a randomised phase III study: 5-year analysis of the EORTC-NCIC trial. Lancet Oncol 2009:10:459-66). The aim of this study was to investigate if the demonstrated improved survival in the literature translated to clinical practice.Methods: This was a retrospective study including all patients with histologically proven GBM diagnosed from 1999 to 2008 and treated with adjuvant RT at our institution. A total of 273 patients were identified. Statistical analysis was carried out using SPSS v18.Results: The median survival for the whole group (n = 273) over the 10-year period was 7.6 months (95% confidence interval 6.7-8.4 months). Overall, the cumulative probability of survival at 1 and 2 years was 31.5 and 9.4%, respectively. In total, 146 patients received radical RT. 103 patients were treated with radical RT and TMZ and 43 patients received radical RT alone. The median survival for patients receiving radical RT with TMZ was 13.4 months (95% CI 10.9-15.8 months) vs 8.8 months for radical RT alone (95% CI 6.9 - 10.7 months, p = 0.006). 2-year survival figures were 21.2 vs 4.7%, respectively. On multivariate analysis, independent predictors of survival included KPS, RT dose, TMZ and extent of surgery. The strongest predictors of poorer outcome based on the hazard ratio were palliative RT, followed by not receiving TMZ chemotherapy, then KPS <90 and a biopsy only surgical approach.Conclusion: This paper demonstrates improved

  13. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    Science.gov (United States)

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small

  14. Robotic fabrication in architecture, art and design 2014

    CERN Document Server

    Leon, Monica

    2014-01-01

    Robotic automation has become ubiquitous in the modern manufacturing landscape, spanning an overwhelming range of processes and applications-- from small scale force-controlled grinding operations for orthopedic joints to large scale composite manufacturing of aircraft fuselages. Smart factories, seamlessly linked via industrial networks and sensing, have revolutionized mass production, allowing for intelligent, adaptive manufacturing processes across a broad spectrum of industries. Against this background, an emerging group of researchers, designers, and fabricators have begun to apply robotic technology in the pursuit of architecture, art, and design, implementing them in a range of processes and scales. Coupled with computational design tools the technology is no longer relegated to the repetitive production of the assembly line, and is instead being employed for the mass-customization of non-standard components. This radical shift in protocol has been enabled by the development of new design to production...

  15. Robot vision for nuclear advanced robot

    International Nuclear Information System (INIS)

    Nakayama, Ryoichi; Okano, Hideharu; Kuno, Yoshinori; Miyazawa, Tatsuo; Shimada, Hideo; Okada, Satoshi; Kawamura, Astuo

    1991-01-01

    This paper describes Robot Vision and Operation System for Nuclear Advanced Robot. This Robot Vision consists of robot position detection, obstacle detection and object recognition. With these vision techniques, a mobile robot can make a path and move autonomously along the planned path. The authors implemented the above robot vision system on the 'Advanced Robot for Nuclear Power Plant' and tested in an environment mocked up as nuclear power plant facilities. Since the operation system for this robot consists of operator's console and a large stereo monitor, this system can be easily operated by one person. Experimental tests were made using the Advanced Robot (nuclear robot). Results indicate that the proposed operation system is very useful, and can be operate by only person. (author)

  16. Middleware Interoperability for Robotics: A ROS-YARP Framework

    Directory of Open Access Journals (Sweden)

    Plinio Moreno

    2016-10-01

    Full Text Available Middlewares are fundamental tools for progress in research and applications in robotics. They enable the integration of multiple heterogeneous sensing and actuation devices, as well as providing general purpose modules for key robotics functions (kinematics, navigation, planning. However, no existing middleware yet provides a complete set of functionalities for all robotics applications, and many robots may need to rely on more than one framework. This paper focuses on the interoperability between two of the most prevalent middleware in robotics: YARP and ROS. Interoperability between middlewares should ideally allow users to execute existing software without the necessity of: (i changing the existing code, and (ii writing hand-coded ``bridges'' for each use-case. We propose a framework enabling the communication between existing YARP modules and ROS nodes for robotics applications in an automated way. Our approach generates the ``bridging gap'' code from a configuration file, connecting YARP ports and ROS topics through code-generated YARP Bottles. %%The configuration file must describe: (i the sender entities, (ii the way to group and convert the information read from the sender, (iii the structure of the output message and (iv the receiving entity. Our choice for the many inputs to one output is the most common use-case in robotics applications, where examples include filtering, decision making and visualization. %We support YARP/ROS and ROS/YARP sender/receiver configurations, which are demonstrated in a humanoid on wheels robot that uses YARP for upper body motor control and visual perception, and ROS for mobile base control and navigation algorithms.

  17. Selected specific rates of reactions of transients from water in aqueous solution. III. Hydroxyl radical and perhydroxyl radical and their radical ions

    Energy Technology Data Exchange (ETDEWEB)

    Ross, F; Ross, A B

    1977-01-01

    Rates of reactions of OH and HO/sub 2/ with organic and inorganic molecules, ions and transients in aqueous solution have been tabulated, as well as the rates for the corresponding radical ions in aqueous solution (O/sup -/ and O/sub 2//sup -/). Most of the rates have been obtained by radiation chemistry methods, both pulsed and steady-state; data from photochemistry and thermal methods are also included. Rates for over one thousand reactions are listed.

  18. [Generation of Superoxide Radicals by Complex III in Heart Mitochondria and Antioxidant Effect of Dinitrosyl Iron Complexes at Different Partial Pressure of Oxygen].

    Science.gov (United States)

    Dudylina, A L; Ivanova, M V; Shumaev, K B; Ruuge, E K

    2016-01-01

    The EPR spin-trapping technique and EPR-oximetry were used to study generation of superoxide radicals in heart mitochondria isolated from Wistar rats under conditions of variable oxygen concentration. Lithium phthalocyanine and TEMPONE-15N-D16 were chosen to determine oxygen content in a gas-permeable capillary tube containing mitochondria. TIRON was used as a spin trap. We investigated the influence of different oxygen concentrations in incubation mixture and demonstrated that heart mitochondria can generate superoxide in complex III at different partial pressure of oxygen as well as under the conditions of deep hypoxia (partial pressure of oxygen, but the magnitude and kinetic characteristics of the effect depended on the concentration of the drug.

  19. Risk factors for postoperative complications in robotic general surgery.

    Science.gov (United States)

    Fantola, Giovanni; Brunaud, Laurent; Nguyen-Thi, Phi-Linh; Germain, Adeline; Ayav, Ahmet; Bresler, Laurent

    2017-03-01

    The feasibility and safety of robotically assisted procedures in general surgery have been reported from various groups worldwide. Because postoperative complications may lead to longer hospital stays and higher costs overall, analysis of risk factors for postoperative surgical complications in this subset of patients is clinically relevant. The goal of this study was to identify risk factors for postoperative morbidity after robotic surgical procedures in general surgery. We performed an observational monocentric retrospective study. All consecutive robotic surgical procedures from November 2001 to December 2013 were included. One thousand consecutive general surgery patients met the inclusion criteria. The mean overall postoperative morbidity and major postoperative morbidity (Clavien >III) rates were 20.4 and 6 %, respectively. This included a conversion rate of 4.4 %, reoperation rate of 4.5 %, and mortality rate of 0.2 %. Multivariate analysis showed that ASA score >3 [OR 1.7; 95 % CI (1.2-2.4)], hematocrit value surgery [OR 1.5; 95 % CI (1-2)], advanced dissection [OR 5.8; 95 % CI (3.1-10.6)], and multiquadrant surgery [OR 2.5; 95 % CI (1.7-3.8)] remained independent risk factors for overall postoperative morbidity. It also showed that advanced dissection [OR 4.4; 95 % CI (1.9-9.6)] and multiquadrant surgery [OR 4.4; 95 % CI (2.3-8.5)] remained independent risk factors for major postoperative morbidity (Clavien >III). This study identifies independent risk factors for postoperative overall and major morbidity in robotic general surgery. Because these factors independently impacted postoperative complications, we believe they could be taken into account in future studies comparing conventional versus robot-assisted laparoscopic procedures in general surgery.

  20. An overview of the 2009 Fort Hood Robotics Rodeo

    Science.gov (United States)

    Norberg, Seth

    2010-04-01

    The Robotics Rodeo held from 31 August to 3 September 2009 at Fort Hood, Texas, had three stated goals: educate key decision makers and align the robotics industry; educate Soldiers and developers; and perform a live market survey of the current state of technologies to encourage the development of robotic systems to support operational needs. Both events that comprised the Robotics Rodeo, the Extravaganza and the robotic technology observation, demonstration and discussion (RTOD2) addressed these stated goals. The Extravaganza was designed to foster interaction between the vendors and the visitors who included the media, Soldiers, others in the robotics industry and key decision makers. The RTOD2 allowed the vendors a more private and focused interaction with the subject matter experts teams, this was the forum for the vendors to demonstrate their robotic systems that supported the III Corps operational needs statements that are focused on route clearance, convoy operations, persistent stare, and robotic wingman. While the goals of the Rodeo were achieved, the underlying success from the event is the development of a new business model that is focused on collapsing the current model to get technologies into the hands of our warfighters quicker. This new model takes the real time data collection from the Rodeo, the Warfighter Needs from TRADOC, the emerging requirements from our current engagements, and assistance from industry partners to develop a future Army strategy for the rapid fielding of unmanned systems technologies.

  1. Ferrous-activated persulfate oxidation of arsenic(III) and diuron in aquatic system

    International Nuclear Information System (INIS)

    Zhou, Lei; Zheng, Wei; Ji, Yuefei; Zhang, Jinfeng; Zeng, Chao; Zhang, Ya; Wang, Qi; Yang, Xi

    2013-01-01

    Highlights: • Effective oxidation of As(III)/diuron is achieved by Fe(II)-activated persulfate. • Hydroxyl and sulfate radical play important roles in As(III) and diuron oxidation. • CA and Na 2 S 2 O 3 are efficient and environmental friendly chelating agents. • DFT calculation is found to be useful for degradation products prediction. -- Abstract: In situ chemical oxidation (ISCO) can be an effective technology for the remediation of soil and groundwater polluted by organic and inorganic contaminants. This study investigated the oxidation of arsenic(III) (As(III)) and diuron using ferrous activated persulfate-based ISCO. The results indicated that Fe(II)/persulfate oxidation could be an effective method to oxidize As(III) and diuron. Effects of pH, S 2 O 8 2− and Fe(II) amounts on the destruction of As(III) and diuron were examined in batch experiments. Acidic conditions favored the removal of As(III) and diuron. Four chelating agents, citric acid (CA), Na 2 S 2 O 3 , diethylene triamine pentaacetic acid (DTPA) and ethylene diamine tetraacetic acid disodium (EDTA-Na 2 ) were used in attempt to maintain the quantity of ferrous ion in solution. In our experiments, CA and Na 2 S 2 O 3 were found to be more effective than DTPA and EDTA-Na 2 . Our results also revealed a widely practical prospect of inorganic chelating agent Na 2 S 2 O 3 . Hydroxyl and sulfate radical were determined to play key roles in the oxidation process by using ethanol and tertiary butanol as molecular probes. Oxidation of As(III) yielded As(V) via the electron-transfer reaction. In the oxidation process of diuron, a stepwise nucleophilic substitution of chlorine by hydroxyl and a stepwise oxidation process of the methyl on the dimethylurea group by hydroxyl and sulfate radical were proposed

  2. More About Hazard-Response Robot For Combustible Atmospheres

    Science.gov (United States)

    Stone, Henry W.; Ohm, Timothy R.

    1995-01-01

    Report presents additional information about design and capabilities of mobile hazard-response robot called "Hazbot III." Designed to operate safely in combustible and/or toxic atmosphere. Includes cameras and chemical sensors helping human technicians determine location and nature of hazard so human emergency team can decide how to eliminate hazard without approaching themselves.

  3. Robotics

    Science.gov (United States)

    Popov, E. P.; Iurevich, E. I.

    The history and the current status of robotics are reviewed, as are the design, operation, and principal applications of industrial robots. Attention is given to programmable robots, robots with adaptive control and elements of artificial intelligence, and remotely controlled robots. The applications of robots discussed include mechanical engineering, cargo handling during transportation and storage, mining, and metallurgy. The future prospects of robotics are briefly outlined.

  4. Radical fashion and radical fashion innovation

    NARCIS (Netherlands)

    Zhang, D.; Benedetto, Di A.C.

    2010-01-01

    This is a study of the related concepts of radical fashion and radical fashion innovation. Radical fashions are defined here as those that may never enter the market at all, and exist primarily on runway shows, in exhibitions and in publicity; by contrast, radical fashion innovations may be very

  5. Development of a Three-dimensional Surgical Navigation System with Magnetic Resonance Angiography and a Three-dimensional Printer for Robot-assisted Radical Prostatectomy.

    Science.gov (United States)

    Jomoto, Wataru; Tanooka, Masao; Doi, Hiroshi; Kikuchi, Keisuke; Mitsuie, Chiemi; Yamada, Yusuke; Suzuki, Toru; Yamano, Toshiko; Ishikura, Reiichi; Kotoura, Noriko; Yamamoto, Shingo

    2018-01-02

    We sought to develop a surgical navigation system using magnetic resonance angiography (MRA) and a three-dimensional (3D) printer for robot-assisted radical prostatectomy (RARP). Six patients with pathologically proven localized prostate cancer were prospectively enrolled in this study. Prostate magnetic resonance imaging (MRI), consisting of T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) and true fast imaging with steady-state precession (true FISP), reconstructed by volume rendering, was followed by dynamic contrast-enhanced MRA performed with a volumetric interpolated breath-hold examination (VIBE) during intravenous bolus injection of gadobutrol. Images of arterial and venous phases were acquired over approximately 210 seconds. Selected images were sent to a workstation for generation of 3D volume-rendered images and standard triangulated language (STL) files for 3D print construction. The neurovascular bundles (NVBs) were found in sequence on non-contrast images. Accessory pudendal arteries (APAs) were found in all cases in the arterial phase of contrast enhancement but were ill-defined on non-contrast enhanced MRA. Dynamic contrast-enhanced MRA helped to detect APAs, suggesting that this 3D system using MRI will be useful in RARP.

  6. Robot 2015 : Second Iberian Robotics Conference : Advances in Robotics

    CERN Document Server

    Moreira, António; Lima, Pedro; Montano, Luis; Muñoz-Martinez, Victor

    2016-01-01

    This book contains a selection of papers accepted for presentation and discussion at ROBOT 2015: Second Iberian Robotics Conference, held in Lisbon, Portugal, November 19th-21th, 2015. ROBOT 2015 is part of a series of conferences that are a joint organization of SPR – “Sociedade Portuguesa de Robótica/ Portuguese Society for Robotics”, SEIDROB – Sociedad Española para la Investigación y Desarrollo de la Robótica/ Spanish Society for Research and Development in Robotics and CEA-GTRob – Grupo Temático de Robótica/ Robotics Thematic Group. The conference organization had also the collaboration of several universities and research institutes, including: University of Minho, University of Porto, University of Lisbon, Polytechnic Institute of Porto, University of Aveiro, University of Zaragoza, University of Malaga, LIACC, INESC-TEC and LARSyS. Robot 2015 was focussed on the Robotics scientific and technological activities in the Iberian Peninsula, although open to research and delegates from other...

  7. Spatiotemporal Aspects of Engagement during Dialogic Storytelling Child–Robot Interaction

    Directory of Open Access Journals (Sweden)

    Scott Heath

    2017-06-01

    individual, and (iii a robot’s sequential mode of interaction can facilitate engagement, despite some social events being ignored by the robot.

  8. Construction of the Cleo III drift chamber

    International Nuclear Information System (INIS)

    Csorna, S.; Marka, S.; Dickson, M.; Dombrowski, S. von; Peterson, D.; Thies, P.; Glenn, S.; Thorndike, E.H.; Kravchenko, I.

    1998-01-01

    The CLEO III group is constructing a new chamber to be installed as part of the staged luminosity upgrade program at the Cornell electron storage ring and compatible with the interaction region optics. Although having less radial extent than the current CLEO II tracking system, CLEO III will have equivalent momentum resolution because of material reduction in the drift chamber inner skin and gas. The thin inner skin requires special attention to the end-plate motion due to wire creep. During stringing, use of a robot will fully automate the wire handling on the upper end. (author)

  9. Synergy between low and high energy radical femtochemistry

    International Nuclear Information System (INIS)

    Gauduel, Y A

    2011-01-01

    The deleterious effects of ionizing radiation on integrated biological targets being dependent on the spatio-temporal distribution of short-lived radical processes, a thorough knowledge of these early events requires a real-time probing in the range 10 -15 - 10 -10 s. This manuscript review is focused on the synergy that exists between low (1-10 eV) and high (MeV) energy radiation femtochemistry (LERF, HERF respectively). The synergy remains crucial for the investigation of primary radical processes that take place within the prethermal regime of low energy secondary electrons. The quantum character of very-short lived electron in a prehydrated configuration provides a unique sub-nanometric probe to spatially explore some early radiation-induced biomolecular damage. This approach would foreshadow the development of innovative applications for spatio-temporal radiation biology such as, i) a highly-selective pro-drug activation using well-defined quantum states of short-lived radicals, ii) the real-time nanodosimetry in biologically relevant environments, and iii) the ultrashort irradiation of living cells.

  10. Two-port robotic hysterectomy: a novel approach.

    Science.gov (United States)

    Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi

    2018-03-24

    The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.

  11. Robots Learn to Recognize Individuals from Imitative Encounters with People and Avatars

    Science.gov (United States)

    Boucenna, Sofiane; Cohen, David; Meltzoff, Andrew N.; Gaussier, Philippe; Chetouani, Mohamed

    2016-02-01

    Prior to language, human infants are prolific imitators. Developmental science grounds infant imitation in the neural coding of actions, and highlights the use of imitation for learning from and about people. Here, we used computational modeling and a robot implementation to explore the functional value of action imitation. We report 3 experiments using a mutual imitation task between robots, adults, typically developing children, and children with Autism Spectrum Disorder. We show that a particular learning architecture - specifically one combining artificial neural nets for (i) extraction of visual features, (ii) the robot’s motor internal state, (iii) posture recognition, and (iv) novelty detection - is able to learn from an interactive experience involving mutual imitation. This mutual imitation experience allowed the robot to recognize the interactive agent in a subsequent encounter. These experiments using robots as tools for modeling human cognitive development, based on developmental theory, confirm the promise of developmental robotics. Additionally, findings illustrate how person recognition may emerge through imitative experience, intercorporeal mapping, and statistical learning.

  12. Cultural Robotics: The Culture of Robotics and Robotics in Culture

    OpenAIRE

    Hooman Samani; Elham Saadatian; Natalie Pang; Doros Polydorou; Owen Noel Newton Fernando; Ryohei Nakatsu; Jeffrey Tzu Kwan Valino Koh

    2013-01-01

    In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. Ac...

  13. Health care cost consequences of using robot technology for hysterectomy

    DEFF Research Database (Denmark)

    Laursen, Karin Rosenkilde; Hyldgård, Vibe Bolvig; Jensen, Pernille Tine

    2017-01-01

    The objective of this study is to examine the costs attributable to robotic-assisted laparoscopic hysterectomy from a broad healthcare sector perspective in a register-based longitudinal study. The population in this study were 7670 consecutive women undergoing hysterectomy between January 2006...... and August 2013 in public hospitals in Denmark. The interventions in the study were total and radical hysterectomy performed robotic-assisted laparoscopic hysterectomy (RALH), total laparoscopic hysterectomy (TLH), or open abdominal hysterectomy (OAH). Service use in the healthcare sector was evaluated 1...... year before to 1 year after the surgery. Tariffs of the activity-based remuneration system and the diagnosis-related grouping case-mix system were used for valuation of primary and secondary care, respectively. Costs attributable to RALH were estimated using a difference-in-difference analytical...

  14. Robot Actors, Robot Dramaturgies

    DEFF Research Database (Denmark)

    Jochum, Elizabeth

    This paper considers the use of tele-operated robots in live performance. Robots and performance have long been linked, from the working androids and automata staged in popular exhibitions during the nineteenth century and the robots featured at Cybernetic Serendipity (1968) and the World Expo...

  15. A study on an autonomous pipeline maintenance robot, 5

    International Nuclear Information System (INIS)

    Fukuda, Toshio; Hosokai, Hidemi; Otsuka, Masashi.

    1989-01-01

    The path planning is very important for the pipeline maintenance robot because there are many obstacles on pipeline such as flanges and T-joints and others, and because pipelines are constructed as a connected network in a very complicated way. Furthermore the maintenance robot Mark III previously reported has the ability to transit from one pipe to another the path planner should consider. The expert system especially aimed for path planning, named PPES (Path Planning Expert System), is described in this paper. A human-operator has only to give some tasks to this system. This system automatically replies with the optimal path, which is based on the calculation of the task levels and list of some control commands. Task level is a criterion to determine one optimal path. It consists of the difference of potential energies, the static joint torques, velocity of the robot, step numbers of the grippers' or body's movement, which the robot requires. This system also has graphic illustrations, so that the operator can easily check and understand the plant map and the result of the path planning. (author)

  16. Cost-effectiveness of open versus laparoscopic versus robotic-assisted laparoscopic cystectomy and urinary diversion.

    Science.gov (United States)

    Zehnder, Pascal; Gill, Inderbir S

    2011-09-01

    To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses. Most economic evaluations are from a hospital perspective and summarize short-term perioperative therapeutic costs. However, the contributing factors (e.g. study design, included variables, robotic amortization plan, supply contract, surgical volume, surgeons' experience, etc.) vary substantially between the institutions. In addition, a real cost-effective analysis considering cost per quality-adjusted life-year gained is not feasible because of the lack of long-term oncologic and functional outcome data with the robotic procedure. On the basis of a modeled cost analysis using results from published series, robotic-assisted cystectomy was - with few exceptions - found to be more expensive when compared with the open approach. Immediate costs are affected most by operative time, followed by length of hospital stay, robotic supply, case volume, robotic cost, and transfusion rate. Any complication substantially impacts overall costs. Economic cost evaluations are complex analyses influenced by numerous factors that hardly allow an interinstitutional comparison. Robotic-assisted cystectomy is constantly refined with many institutions being somewhere on their learning curve. Transparent reports of oncologic and functional outcome data from centers of expertise applying standardized methods will help to properly analyze the real long-term benefits of robotic surgery and successor technologies and prevent us from becoming slaves of successful marketing strategies.

  17. Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots.

    Science.gov (United States)

    d'Elia, Nicolò; Vanetti, Federica; Cempini, Marco; Pasquini, Guido; Parri, Andrea; Rabuffetti, Marco; Ferrarin, Maurizio; Molino Lova, Raffaele; Vitiello, Nicola

    2017-04-14

    In human-centered robotics, exoskeletons are becoming relevant for addressing needs in the healthcare and industrial domains. Owing to their close interaction with the user, the safety and ergonomics of these systems are critical design features that require systematic evaluation methodologies. Proper transfer of mechanical power requires optimal tuning of the kinematic coupling between the robotic and anatomical joint rotation axes. We present the methods and results of an experimental evaluation of the physical interaction with an active pelvis orthosis (APO). This device was designed to effectively assist in hip flexion-extension during locomotion with a minimum impact on the physiological human kinematics, owing to a set of passive degrees of freedom for self-alignment of the human and robotic hip flexion-extension axes. Five healthy volunteers walked on a treadmill at different speeds without and with the APO under different levels of assistance. The user-APO physical interaction was evaluated in terms of: (i) the deviation of human lower-limb joint kinematics when wearing the APO with respect to the physiological behavior (i.e., without the APO); (ii) relative displacements between the APO orthotic shells and the corresponding body segments; and (iii) the discrepancy between the kinematics of the APO and the wearer's hip joints. The results show: (i) negligible interference of the APO in human kinematics under all the experimented conditions; (ii) small (i.e., ergonomics assessment of wearable robots.

  18. The development of radiation hardened robot for nuclear facility - Development of embedded controller for hydraulic robot

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Kook; Kim, Jae Kwon [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    2000-04-01

    We designed and implemented a reliable hierarchical control system for hydraulic robots for nuclear power plant maintenance. In hazardous environments such as nuclear power plants, robot systems or automated equipment should be used instead of human being for maintenance and repair. Such robot should guarantee high reliability in hazardous environments such as high radiation or high temperature. The overall system is composed of three hierarchical subsystems: i) supervisory controller in safe zone for operator interaction with monitoring and commanding and graphic user interface, ii) master controller in semi-hazardous zone for control function, and iii) slave controller in hazardous zone for sensing and actuation. These subsystems are connected with suitable communication channels: a) master-slave communication channel implemented with CAN (Control Area Network) and b) supervisory-master communication with Ethernet. The master and the slave controllers construct a feedback closed-loop control system. In order to improve reliability, the slave controller is duplicated using cold-standby scheme, and master-slave communication channel is also duplicated. The overall system is implemented harmonically, and we obtained fast control interval of 1msec, which is sufficient for high-performance real-time control. 12 refs., 58 figs., 13 tabs. (Author)

  19. Radical formation of irradiated α-alanine and N-acetyl alanine with heavy ion beams. Effects of the irradiation temperature

    International Nuclear Information System (INIS)

    Minegishi, Atsuko; Nagasaki, Jun; Mori, Wasuke; Amano, Chikara; Takagi, Shinji; Murakami, Takeshi; Kanai, Tatsuaki; Furusawa, Yoshiya; Iwata, Yoshiyuki

    2003-01-01

    The characteristics of irradiation with C290 MeV/u ion beams were investigated using X-band electron spin resonance (ESR) spectroscopy for a polycrystalline powder of L-α-alanine at from 77K to 310K. The formed main radicals at 190K∼310K were the deamino radical and the decarboxyl radical. Because of the first-derivative ESR, decarboxyl radical showed an expanded spectral width and a lower peak height because of its amino hydrogen and nitrogen than that of the same amount of deamino radical. The ESR of irradiated L-α-alanine predominantly indicates the spectrum of the deamino radical. On the irradiated, L-α-alanine at from 77K to 310K ESR showed 1:4:6:4:1 lines at 220K and at room temperature, which indicate that the methyl group of the radical was rotating. On the other hand, at 77K ESR the spectrum showed nearly 1:5:5:5:1 lines, like the teeth of a saw, on samples irradiated at 270K∼350K (range IV), and 1:4:6:4:1 lines for those irradiated at 180K∼260K (range II and III), respectively. It is considered that the radical conformation of the deamino radical is planar (most stable conformation) on an irradiated sample in range IV, and a pyramidal structure on the irradiated sample in ranges II and III. (author)

  20. Comparative biomarker expression and RNA integrity in biospecimens derived from radical retropubic and robot-assisted laparoscopic prostatectomies.

    Science.gov (United States)

    Ricciardelli, Carmela; Bianco-Miotto, Tina; Jindal, Shalini; Dodd, Thomas J; Cohen, Penelope A; Marshall, Villis R; Sutherland, Peter D; Samaratunga, Hemamali; Kench, James G; Dong, Ying; Wang, Hong; Clements, Judith A; Risbridger, Gail P; Sutherland, Robert L; Tilley, Wayne D; Horsfall, David J

    2010-07-01

    Knowledge of preanalytic conditions that biospecimens are subjected to is critically important because novel surgical procedures, tissue sampling, handling, and storage might affect biomarker expression or invalidate tissue samples as analytes for some technologies. We investigated differences in RNA quality, gene expression by quantitative real-time PCR, and immunoreactive protein expression of selected prostate cancer biomarkers between tissues from retropubic radical prostatectomy (RRP) and robot-assisted laparoscopic prostatectomy (RALP). Sections of tissue microarray of 23 RALP and 22 RRP samples were stained with antibodies to androgen receptor (AR) and prostate-specific antigen (PSA) as intersite controls, and 14 other candidate biomarkers of research interest to three laboratories within the Australian Prostate Cancer BioResource tissue banking network. Quantitative real-time PCR was done for AR, PSA (KLK3), KLK2, KLK4, and HIF1A on RNA extracted from five RALP and five RRP frozen tissue cores. No histologic differences were observed between RALP and RRP tissue. Biomarker staining grouped these samples into those with increased (PSA, CK8/18, CKHMW, KLK4), decreased (KLK2, KLK14), or no change in expression (AR, ghrelin, Ki67, PCNA, VEGF-C, PAR2, YB1, p63, versican, and chondroitin 0-sulfate) in RALP compared with RRP tissue. No difference in RNA quality or gene expression was detected between RALP and RRP tissue. Changes in biomarker expression between RALP and RRP tissue exist at the immunoreactive protein level, but the etiology is unclear. Future studies should account for changes in biomarker expression when using RALP tissues, and mixed cohorts of RALP and RRP tissue should be avoided.

  1. Electroencephalography (EEG) Based Control in Assistive Mobile Robots: A Review

    International Nuclear Information System (INIS)

    Krishnan, N Murali; Mariappan, Muralindran; Muthukaruppan, Karthigayan; Hijazi, Mohd Hanafi Ahmad; Kitt, Wong Wei

    2016-01-01

    Recently, EEG based control in assistive robot usage has been gradually increasing in the area of biomedical field for giving quality and stress free life for disabled and elderly people. This study reviews the deployment of EGG based control in assistive robots, especially for those who in need and neurologically disabled. The main objective of this paper is to describe the methods used for (i) EEG data acquisition and signal preprocessing, (ii) feature extraction and (iii) signal classification methods. Besides that, this study presents the specific research challenges in the designing of these control systems and future research directions. (paper)

  2. Anesthesiologic Effects of Transperitoneal Versus Extraperitoneal Approach During Robot-Assisted Radical Prostatectomy: Results of a Prospective Randomized Study

    Directory of Open Access Journals (Sweden)

    Fabrizio Dal Moro

    2015-06-01

    Full Text Available ABSTRACTObjectives:To compare the effects of CO2 insufflation on hemodynamics and oxygen levels and on acid-base level during Robot-Assisted Radical Prostatectomy (RARP with transperitoneal (TP versus extra-peritoneal (EP accesses.Materials and Methods:Sixty-two patients were randomly assigned to TP (32 and EP (30 to RARP. Pre-operation data were collected for all patients. Hemodynamic, respiratory and blood acid-base parameters were measured at the moment of induction of anesthesia (T0, after starting CO2 insuffation (T1, and at 60 (T2 and 120 minutes (T3 after insufflation. In all cases, the abdominal pressure was set at 15 mmHg. Complications were reported according to the Clavien-Dindo classification. Student's two–t-test, with a significance level set at pResults:The demographic characteristics of the patients in both groups were statistically comparable. Analysis of intra-operative anesthesiologic parameters showed that partial CO2 pressure during EP was significantly higher than during TP, with a consequent decrease in arterial pH. Other parameters analysed were similar in the two groups. Postoperative complications were comparable between groups. The most important limitations of this study were the small size of the patient groups and the impossibility of maintaining standard abdominal pressure throughout the operational phases, despite attempts to regulate it.Conclusions:This prospective randomized study demonstrates that, from the anesthesiologic viewpoint, during RARP the TP approach is preferable to EP, because of lower CO2 reabsorption and risk of acidosis.

  3. Is Ethics of Robotics about Robots? Philosophy of Robotics Beyond Realism and Individualilsm.

    NARCIS (Netherlands)

    Coeckelbergh, Mark

    2011-01-01

    If we are doing ethics of robotics, what exactly is the object of our inquiry? This paper challenges 'individualist' robot ontology and 'individualist' social philosophy of robots. It is argued that ethics of robotics should not study and evaluate robotics exclusively in terms of individual

  4. Multiple Moving Obstacles Avoidance of Service Robot using Stereo Vision

    Directory of Open Access Journals (Sweden)

    Achmad Jazidie

    2011-12-01

    Full Text Available In this paper, we propose a multiple moving obstacles avoidance using stereo vision for service robots in indoor environments. We assume that this model of service robot is used to deliver a cup to the recognized customer from the starting point to the destination. The contribution of this research is a new method for multiple moving obstacle avoidance with Bayesian approach using stereo camera. We have developed and introduced 3 main modules to recognize faces, to identify multiple moving obstacles and to maneuver of robot. A group of people who is walking will be tracked as a multiple moving obstacle, and the speed, direction, and distance of the moving obstacles is estimated by a stereo camera in order that the robot can maneuver to avoid the collision. To overcome the inaccuracies of vision sensor, Bayesian approach is used for estimate the absense and direction of obstacles. We present the results of the experiment of the service robot called Srikandi III which uses our proposed method and we also evaluate its performance. Experiments shown that our proposed method working well, and Bayesian approach proved increasing the estimation perform for absence and direction of moving obstacle.

  5. Financial Impact of the Robotic Approach in Liver Surgery: A Comparative Study of Clinical Outcomes and Costs Between the Robotic and Open Technique in a Single Institution.

    Science.gov (United States)

    Daskalaki, Despoina; Gonzalez-Heredia, Raquel; Brown, Marc; Bianco, Francesco M; Tzvetanov, Ivo; Davis, Myriam; Kim, Jihun; Benedetti, Enrico; Giulianotti, Pier C

    2017-04-01

    One of the perceived major drawbacks of minimally invasive techniques has always been its cost. This is especially true for the robotic approach and is one of the main reasons that has prevented its wider acceptance among hospitals and surgeons. The aim of our study was to evaluate the clinical outcomes and economic impact of robotic and open liver surgery in a single institution. Sixty-eight robotic and 55 open hepatectomies were performed at our institution between January 1, 2009 and December 31, 2013. Demographics, perioperative data, and postoperative outcomes were collected and compared between the two groups. An independent company performed the financial analysis. The economic parameters comprised direct variable costs, direct fixed costs, and indirect costs. Mean estimated blood loss was significantly less in the robotic group (438 versus 727.8 mL; P = .038). Overall morbidity was significantly lower in the robotic group (22% versus 40%; P = .047). Clavien III/IV complications were also lower, with 4.4% in the robotic versus 16.3% in the open group (P = .043). The length of stay in the intensive care unit (ICU) was shorter for patients who underwent a robotic procedure (2.1 versus 3.3 days; P = .004). The average total cost, including readmissions, was $37,518 for robotic surgery and $41,948 for open technique. Robotic liver resections had less overall morbidity, ICU, and hospital stay. This translates into decreased average costs for robotic surgery. These procedures are financially comparable to open resections and do not represent a financial burden to the hospital.

  6. Ferrous-activated persulfate oxidation of arsenic(III) and diuron in aquatic system

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Lei [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023 (China); Zheng, Wei [Jiangsu Product Quality Supervision and Inspection Research Institute, Nanjing 210007 (China); Ji, Yuefei [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023 (China); Université Lyon 1, UMR CNRS 5256, Institut de recherches sur la catalyse et l’environnement de Lyon (IRCELYON), 2 Avenue Albert Einstein, F-69626 Villeurbanne (France); Zhang, Jinfeng; Zeng, Chao; Zhang, Ya; Wang, Qi [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023 (China); Yang, Xi, E-mail: yangxi@nju.edu.cn [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023 (China)

    2013-12-15

    Highlights: • Effective oxidation of As(III)/diuron is achieved by Fe(II)-activated persulfate. • Hydroxyl and sulfate radical play important roles in As(III) and diuron oxidation. • CA and Na{sub 2}S{sub 2}O{sub 3} are efficient and environmental friendly chelating agents. • DFT calculation is found to be useful for degradation products prediction. -- Abstract: In situ chemical oxidation (ISCO) can be an effective technology for the remediation of soil and groundwater polluted by organic and inorganic contaminants. This study investigated the oxidation of arsenic(III) (As(III)) and diuron using ferrous activated persulfate-based ISCO. The results indicated that Fe(II)/persulfate oxidation could be an effective method to oxidize As(III) and diuron. Effects of pH, S{sub 2}O{sub 8}{sup 2−} and Fe(II) amounts on the destruction of As(III) and diuron were examined in batch experiments. Acidic conditions favored the removal of As(III) and diuron. Four chelating agents, citric acid (CA), Na{sub 2}S{sub 2}O{sub 3}, diethylene triamine pentaacetic acid (DTPA) and ethylene diamine tetraacetic acid disodium (EDTA-Na{sub 2}) were used in attempt to maintain the quantity of ferrous ion in solution. In our experiments, CA and Na{sub 2}S{sub 2}O{sub 3} were found to be more effective than DTPA and EDTA-Na{sub 2}. Our results also revealed a widely practical prospect of inorganic chelating agent Na{sub 2}S{sub 2}O{sub 3}. Hydroxyl and sulfate radical were determined to play key roles in the oxidation process by using ethanol and tertiary butanol as molecular probes. Oxidation of As(III) yielded As(V) via the electron-transfer reaction. In the oxidation process of diuron, a stepwise nucleophilic substitution of chlorine by hydroxyl and a stepwise oxidation process of the methyl on the dimethylurea group by hydroxyl and sulfate radical were proposed.

  7. Exploratorium: Robots.

    Science.gov (United States)

    Brand, Judith, Ed.

    2002-01-01

    This issue of Exploratorium Magazine focuses on the topic robotics. It explains how to make a vibrating robotic bug and features articles on robots. Contents include: (1) "Where Robot Mice and Robot Men Run Round in Robot Towns" (Ray Bradbury); (2) "Robots at Work" (Jake Widman); (3) "Make a Vibrating Robotic Bug" (Modesto Tamez); (4) "The Robot…

  8. Infrared Spectra of the n-PROPYL and i-PROPYL Radicals in Solid Para-Hydrogen

    Science.gov (United States)

    Pullen, Gregory T.; Franke, Peter R.; Douberly, Gary E.; Lee, Yuan-Pern

    2017-06-01

    We report the infrared spectra of the n-propyl and i-propyl radicals measured in solid para-hydrogen (p-H_2) matrices at 3.2 K. n-Propyl and i-propyl radicals were produced via the 248 nm irradiation of matrices formed by co-depositing p-H_2 and either 1-Iodopropane (n-propyl) or 2-Iodopropane (i-propyl). Secondary photolysis was used to group spectral lines all due to the same species. Lines in the C-H stretching region were compared to previous work using the Helium Nanodroplet Isolation (HENDI) technique, and are in excellent agreement. In addition to a few lines previously measured in Ar matrices, we observe many previously unreported bands below 2000 \\wn, which we attribute to the n-propyl and i-propyl radicals. The assignment of features below 2000 \\wn are made via comparisons to anharmonic VPT2+K frequency computations. Peter R. Franke, Daniel P. Tabor, Christopher P. Moradi, Gary E. Douberly, Jay Agarwal, Henry F. Schaefer III, and Edwin L. Sibert III, Journal of Chemical Physics 145, 224304 (2016).

  9. Robotics

    International Nuclear Information System (INIS)

    Scheide, A.W.

    1983-01-01

    This article reviews some of the technical areas and history associated with robotics, provides information relative to the formation of a Robotics Industry Committee within the Industry Applications Society (IAS), and describes how all activities relating to robotics will be coordinated within the IEEE. Industrial robots are being used for material handling, processes such as coating and arc welding, and some mechanical and electronics assembly. An industrial robot is defined as a programmable, multifunctional manipulator designed to move material, parts, tools, or specialized devices through variable programmed motions for a variety of tasks. The initial focus of the Robotics Industry Committee will be on the application of robotics systems to the various industries that are represented within the IAS

  10. Collagen Type III Metabolism Evaluation in Patients with Malignant Head and Neck Cancer Treated with Radiotherapy

    Directory of Open Access Journals (Sweden)

    Klaudia Mazurek

    2018-01-01

    Full Text Available Ionizing radiation affects the metabolism of key proteins of extracellular matrix including type III collagen, an important component of human skin. The aim of the work is an analysis of the impact of radical and palliative radiotherapy on collagen type III synthesis in patients with head and neck cancer. The test group consisted of 56 males with histopathologically confirmed head and neck cancer, for whom radiotherapy was applied as a form of radical or palliative treatment. The level of procollagen III aminoterminal propeptide (PIIINP, which is a marker of collagen type III synthesis, was determined in blood serum before radiotherapy, immediately following radiotherapy, and 3 months after it was finished. As a result of radical radiotherapy a statistically significant decrease of PIIINP levels in serum (p<0.0001 was observed, both immediately after the radiotherapy and 3 months after the end of the treatment. Also the palliative radiotherapy caused a significant decrease of PIIINP right after the treatment (p=0.0052, as well as during the examination performed 3 months later (p=0.0004. The achieved results suggest that PIIINP can be used as a marker helpful in assessing radiation damage to connective tissue.

  11. Application of autonomous robotics to surveillance of waste storage containers for radioactive surface contamination

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Beckerman, M.; Butler, P.L.; Jones, J.P.; Reister, D.B.

    1991-01-01

    This paper describes a proof-of-principal demonstration performed with the HERMIES-III mobile robot to automate the inspection of waste storage drums for radioactive surface contamination and thereby reduce the human burden of operating a robot and worker exposure to potentially hazardous environments. Software and hardware for the demonstration were developed by a team consisting of Oak Ridge National Laboratory, and the Universities of Florida, Michigan, Tennessee, and Texas. Robot navigation, machine vision, manipulator control, parallel processing and human-machine interface techniques developed by the team were demonstrated utilizing advanced computer architectures. The demonstration consists of over 100,000 lines of computer code executing on nine computers

  12. Advantages of Task-Specific Multi-Objective Optimisation in Evolutionary Robotics.

    Science.gov (United States)

    Trianni, Vito; López-Ibáñez, Manuel

    2015-01-01

    The application of multi-objective optimisation to evolutionary robotics is receiving increasing attention. A survey of the literature reveals the different possibilities it offers to improve the automatic design of efficient and adaptive robotic systems, and points to the successful demonstrations available for both task-specific and task-agnostic approaches (i.e., with or without reference to the specific design problem to be tackled). However, the advantages of multi-objective approaches over single-objective ones have not been clearly spelled out and experimentally demonstrated. This paper fills this gap for task-specific approaches: starting from well-known results in multi-objective optimisation, we discuss how to tackle commonly recognised problems in evolutionary robotics. In particular, we show that multi-objective optimisation (i) allows evolving a more varied set of behaviours by exploring multiple trade-offs of the objectives to optimise, (ii) supports the evolution of the desired behaviour through the introduction of objectives as proxies, (iii) avoids the premature convergence to local optima possibly introduced by multi-component fitness functions, and (iv) solves the bootstrap problem exploiting ancillary objectives to guide evolution in the early phases. We present an experimental demonstration of these benefits in three different case studies: maze navigation in a single robot domain, flocking in a swarm robotics context, and a strictly collaborative task in collective robotics.

  13. Advantages of Task-Specific Multi-Objective Optimisation in Evolutionary Robotics.

    Directory of Open Access Journals (Sweden)

    Vito Trianni

    Full Text Available The application of multi-objective optimisation to evolutionary robotics is receiving increasing attention. A survey of the literature reveals the different possibilities it offers to improve the automatic design of efficient and adaptive robotic systems, and points to the successful demonstrations available for both task-specific and task-agnostic approaches (i.e., with or without reference to the specific design problem to be tackled. However, the advantages of multi-objective approaches over single-objective ones have not been clearly spelled out and experimentally demonstrated. This paper fills this gap for task-specific approaches: starting from well-known results in multi-objective optimisation, we discuss how to tackle commonly recognised problems in evolutionary robotics. In particular, we show that multi-objective optimisation (i allows evolving a more varied set of behaviours by exploring multiple trade-offs of the objectives to optimise, (ii supports the evolution of the desired behaviour through the introduction of objectives as proxies, (iii avoids the premature convergence to local optima possibly introduced by multi-component fitness functions, and (iv solves the bootstrap problem exploiting ancillary objectives to guide evolution in the early phases. We present an experimental demonstration of these benefits in three different case studies: maze navigation in a single robot domain, flocking in a swarm robotics context, and a strictly collaborative task in collective robotics.

  14. Towards Versatile Robots Through Open Heterogeneous Modular Robots

    DEFF Research Database (Denmark)

    Lyder, Andreas

    arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a modular robot to be a robot consisting of dynamically reconfigurable modules. The goal of this thesis......Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem...... is to increase the versatility and practical usability of modular robots by introducing new conceptual designs. Until now modular robots have been based on a pre-specified set of modules, and thus, their functionality is limited. We propose an open heterogeneous design concept, which allows a modular robot...

  15. The risk of urinary retention following robot-assisted radical prostatectomy and its impact on early continence outcomes.

    Science.gov (United States)

    Alnazari, Mansour; Zanaty, Marc; Ajib, Khaled; El-Hakim, Assaad; Zorn, Kevin C

    2017-12-22

    We aimed to evaluate the risk factors of acute urinary retention (AUR) following robot-assisted radical prostatectomy (RARP), as well as the relationship of AUR with early continence outcomes. The records of 740 consecutive patients who underwent RARP by two experienced surgeons at our institution were retrospectively reviewed from a prospectively collected database. Multiple factors, including age, body mass index (BMI), international prostate symptom score (IPSS), prostate volume, presence of median lobe, nerve preservation status, anastomosis time, and catheter removal time (Day 4 vs. 7), were evaluated as risk factors for AUR using univariate and multivariate analysis. The relation between AUR and early return of continence (one and three months) post-RARP was also evaluated. The incidence of clinically significant vesico-urethral anastomotic (VUA) leak and AUR following catheter removal were 0.9% and 2.2% (17/740), respectively. In men who developed AUR, there was no significant relationship with regards to age, BMI, IPSS, prostatic volume, median lobe, nerve preservation, or anastomosis time; however, the incidence of AUR was significantly higher for men with catheter removal at Day 4 (4.5% [16/351]) vs. Day 7 (0.2% [1/389]) (p=0.004). Moreover, patients with early removal of the catheter (Day 4) who developed AUR had an earlier one-month return of 0-pad continence 87.5% (14/16) compared to patients without AUR 45.6% (153/335), with no significant difference at three months. While AUR is an uncommon complication of RARP, its incidence is much higher than VUA leakage. Further, it is often not well-discussed during patient counselling preoperatively. Moreover, earlier return of urinary continence was observed in patients experiencing AUR following RARP exclusively with catheter removal at Day 4. Future studies are warranted to validate the long-term impact of AUR on continence outcomes.

  16. Lessons learned over a decade of pediatric robotic ureteral reimplantation

    Directory of Open Access Journals (Sweden)

    Minki Baek

    2017-01-01

    Full Text Available The da Vinci robotic system has improved surgeon dexterity, ergonomics, and visualization to allow for a minimally invasive option for complex reconstructive procedures in children. Over the past decade, robot-assisted laparoscopic ureteral reimplantation (RALUR has become a viable minimally invasive surgical option for pediatric vesicoureteral reflux (VUR. However, higher-thanexpected complication rates and suboptimal reflux resolution rates at some centers have also been reported. The heterogeneity of surgical outcomes may arise from the inherent and underestimated complexity of the RALUR procedure that may justify its reclassification as a complex reconstructive procedure and especially for robotic surgeons early in their learning curve. Currently, no consensus exists on the role of RALUR for the surgical management of VUR. High success rates and low major complication rates are the expected norm for the current gold standard surgical option of open ureteral reimplantation. Similar to how robot-assisted laparoscopic surgery has gradually replaced open surgery as the most utilized option for prostatectomy in prostate cancer patients, RALUR may become a higher utilized surgical option in children with VUR if the adoption of standardized surgical techniques that have been associated with optimal outcomes can be adopted during the second decade of RALUR. A future standard of RALUR for children with VUR whose parents seek a minimally invasive surgical option can arise if widespread achievement of high success rates and low major complication rates can be obtained, similar to the replacement of open surgery with robot-assisted laparoscopic radical prostectomy as the new strandard for men with prostate cancer.

  17. Reverse Stage Shift at a Tertiary Care Center: Escalating Risk in Men Undergoing Radical Prostatectomy

    Science.gov (United States)

    Silberstein, Jonathan L.; Vickers, Andrew J.; Power, Nicholas E.; Fine, Samson W.; Scardino, Peter T.; Eastham, James A.; Laudone, Vincent P.

    2011-01-01

    Purpose To evaluate changes in clinical and pathological characteristics of prostate cancer in patients treated surgically at a large tertiary care center in the context of increased use of active surveillance (AS) and minimally invasive surgery (MIS). Materials We performed retrospective review of 6,624 patients with localized prostate cancer who underwent radical prostatectomy from 2000–2010 at Memorial Sloan-Kettering Cancer Center. Patients were stratified by surgical approach (open, laparoscopic or robotic) and risk categories (low, intermediate, or high). Patients with low-risk disease, without intervention and minimum followup of 6 months were considered to have elected AS. Results AS cases increased from <20 per year between 2000–2004 to ≥100 per year between 2007–2009. Over the same decade MIS cases (laparoscopic or robotic) increased from zero to 63% of all surgical cases. The percentage of patients in intermediate- and high-risk categories increased over time, while the percentage in the low-risk category decreased (OR per year 0.91, 95% CI 0.89, 0.92, p <0.0005). The proportion of surgery patients with Gleason 6 tumors decreased over time (OR per year 0.87, 95% CI 0.85, 0.88; p <0.0005) while pathologic stage and Gleason score increased (p <0.0005). The proportion of low-risk cases decreased across all types of surgery, with the largest decrease in robotic surgery (p <0.0005). Conclusions We observed a reverse stage shift in patients undergoing radical prostatectomy since 2000 despite the introduction and rapid proliferation of MIS. These findings may be due to increased use of AS and institutional focus on treatment of higher-risk disease. PMID:21484780

  18. Socially intelligent robots: dimensions of human-robot interaction.

    Science.gov (United States)

    Dautenhahn, Kerstin

    2007-04-29

    Social intelligence in robots has a quite recent history in artificial intelligence and robotics. However, it has become increasingly apparent that social and interactive skills are necessary requirements in many application areas and contexts where robots need to interact and collaborate with other robots or humans. Research on human-robot interaction (HRI) poses many challenges regarding the nature of interactivity and 'social behaviour' in robot and humans. The first part of this paper addresses dimensions of HRI, discussing requirements on social skills for robots and introducing the conceptual space of HRI studies. In order to illustrate these concepts, two examples of HRI research are presented. First, research is surveyed which investigates the development of a cognitive robot companion. The aim of this work is to develop social rules for robot behaviour (a 'robotiquette') that is comfortable and acceptable to humans. Second, robots are discussed as possible educational or therapeutic toys for children with autism. The concept of interactive emergence in human-child interactions is highlighted. Different types of play among children are discussed in the light of their potential investigation in human-robot experiments. The paper concludes by examining different paradigms regarding 'social relationships' of robots and people interacting with them.

  19. Blood Transfusion Requirement and Not Preoperative Anemia Are Associated with Perioperative Complications Following Intracorporeal Robot-Assisted Radical Cystectomy.

    Science.gov (United States)

    Tan, Wei Shen; Lamb, Benjamin W; Khetrapal, Pramit; Tan, Mae-Yen; Tan, Melanie El; Sridhar, Ashwin; Cervi, Elizabeth; Rodney, Simon; Busuttil, Gerald; Nathan, Senthil; Hines, John; Shaw, Greg; Mohammed, Anna; Baker, Hilary; Briggs, Timothy P; Klein, Andrew; Richards, Toby; Kelly, John D

    2017-02-01

    To assess the prevalence of preoperative anemia and the impact of preoperative anemia and blood transfusion requirement on 30- and 90-day complications in a cohort of patients undergoing robot-assisted radical cystectomy with intracorporeal urinary diversion (iRARC). IRARC was performed on 166 patients between June 2011 and March 2016. Prospective data were collected for patient demographics, clinical and pathologic characteristics, perioperative variables, transfusion requirements, and hospital length of stay. Thirty- and 90-day complications were classified according to the modified Memorial Sloan Kettering Cancer Center Clavien-Dindo system. Preoperative anemia was common (43.4%) and greatest in patients receiving neoadjuvant chemotherapy (48.6%) (p blood transfusion (p = 0.001). Blood transfusion required in 20.4% of patients with intraoperative and postoperative blood transfusion rate was 10.2% and 13.9%, respectively. The 30-day all complication rate and 30-day major complication rate were 55.4% and 15.7%, respectively, while 90-day all complication rate and 90-day major complication rate were 65.7% and 19.3%, respectively. Intraoperative blood transfusion was not associated with increased complications, but postoperative blood transfusion requirement was independently associated with perioperative morbidity: all 30-day complications (p = 0.003), all 90-day complications (p = 0.009), and 90-day major complications (p = 0.004). The presence of preoperative anemia in patients undergoing iRARC is not associated with increased surgical risk, although preoperative anemic patients were significantly more likely to require blood transfusion. Blood transfusion requirement and specifically postoperative blood transfusion are independently associated with perioperative morbidity and are an important factor for the optimization of postoperative outcomes.

  20. Robot engineering

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seul

    2006-02-15

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  1. Robot engineering

    International Nuclear Information System (INIS)

    Jung, Seul

    2006-02-01

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  2. Orgasm-associated urinary incontinence and sexual life after radical prostatectomy.

    Science.gov (United States)

    Nilsson, Andreas E; Carlsson, Stefan; Johansson, Eva; Jonsson, Martin N; Adding, Christofer; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2011-09-01

    Involuntary release of urine during sexual climax, orgasm-associated urinary incontinence, occurs frequently after radical prostatectomy. We know little about its prevalence and its effect on sexual satisfaction. To determine the prevalence of orgasm-associated incontinence after radical prostatectomy and its effect on sexual satisfaction. Consecutive series, follow-up at one point in calendar time of men having undergone radical prostatectomy (open surgery or robot-assisted laparoscopic surgery) at Karolinska University Hospital, Stockholm, Sweden, 2002-2006. Of the 1,411 eligible men, 1,288 (91%) men completed a study-specific questionnaire. Prevalence rate of orgasm-associated incontinence. Of the 1,288 men providing information, 691 were sexually active. Altogether, 268 men reported orgasm-associated urinary incontinence, of whom 230 (86%) were otherwise continent. When comparing them with the 422 not reporting the symptom but being sexually active, we found a prevalence ratio (with 95% confidence interval) of 1.5 (1.2-1.8) for not being able to satisfy the partner, 2.1 (1.1-3.5) for avoiding sexual activity because of fear of failing, 1.5 (1.1-2.1) for low orgasmic satisfaction, and 1.4 (1.2-1.7) for having sexual intercourse infrequently. Prevalence ratios increase in prostate-cancer survivors with a higher frequency of orgasm-associated urinary incontinence. We found orgasm-associated urinary incontinence to occur among a fifth of prostate cancer survivors having undergone radical prostatectomy, most of whom are continent when not engaged in sexual activity. The symptom was associated with several aspects of sexual life. © 2011 International Society for Sexual Medicine.

  3. Calibration of Robot Reference Frames for Enhanced Robot Positioning Accuracy

    OpenAIRE

    Cheng, Frank Shaopeng

    2008-01-01

    This chapter discussed the importance and methods of conducting robot workcell calibration for enhancing the accuracy of the robot TCP positions in industrial robot applications. It shows that the robot frame transformations define the robot geometric parameters such as joint position variables, link dimensions, and joint offsets in an industrial robot system. The D-H representation allows the robot designer to model the robot motion geometry with the four standard D-H parameters. The robot k...

  4. Peripersonal Space and Margin of Safety around the Body: Learning Visuo-Tactile Associations in a Humanoid Robot with Artificial Skin.

    Science.gov (United States)

    Roncone, Alessandro; Hoffmann, Matej; Pattacini, Ugo; Fadiga, Luciano; Metta, Giorgio

    2016-01-01

    This paper investigates a biologically motivated model of peripersonal space through its implementation on a humanoid robot. Guided by the present understanding of the neurophysiology of the fronto-parietal system, we developed a computational model inspired by the receptive fields of polymodal neurons identified, for example, in brain areas F4 and VIP. The experiments on the iCub humanoid robot show that the peripersonal space representation i) can be learned efficiently and in real-time via a simple interaction with the robot, ii) can lead to the generation of behaviors like avoidance and reaching, and iii) can contribute to the understanding the biological principle of motor equivalence. More specifically, with respect to i) the present model contributes to hypothesizing a learning mechanisms for peripersonal space. In relation to point ii) we show how a relatively simple controller can exploit the learned receptive fields to generate either avoidance or reaching of an incoming stimulus and for iii) we show how the robot can select arbitrary body parts as the controlled end-point of an avoidance or reaching movement.

  5. Robotics Inspection Vehicle for Advanced Storages

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, Emilio; Renaldi, Graziano; Puig, David; Franzetti, Michele; Correcher, Carlos [European Commission, Ispra (Italy). Inst. for the Protection and Security of the Citizen

    2003-05-01

    After the dismantling of nuclear weapons and the probable release of large quantities of weapon graded materials under international verification regimes, there will be a wide interest in unmanned, highly automated and secure storage areas. In such circumstances, robotics technologies can provide an effective answer to the problem of securing, manipulating and inventorying all stored materials. In view of this future application JRC's NPNS started the development and construction of an advanced robotics prototype and demonstration system, named Robotics Inspection Vehicle (RIV), for remote inspection, surveillance and remote handling in those areas. The system was designed to meet requirements of reliability, security, high availability, robustness against radiation effects, self-maintainability (i.e., auto-repair capability), and easy installation. Due to its innovative holonomic design, RIV is a highly maneuverable and agile platform able to move in any direction, including sideways. The platform carries on-board a five degree of freedom manipulator arm. The high maneuverability and operation modes take into account the needs for accessing in the most easy way materials in the storage area. The platform is prepared to operate in one of three modes: i) manual tele-operation, ii) semiautonomous and iii) fully autonomous. The paper describes RIV's main design features, and details its GENERIS based control software [JRC's software architecture for robotics] and embedded sensors (i.e., 3D laser range, transponder antenna, ultra-sound, vision-based robot guidance, force-torque sensors, etc.). RIV was designed to incorporate several JRC innovative surveillance and inspection technologies and reveals that the current state of technology is mature to effectively provide a solution to novel storage solutions. The system is available for demonstration at JRC's Rialto Laboratory.

  6. Ultrasensitive prostate specific antigen assay following laparoscopic radical prostatectomy--an outcome measure for defining the learning curve.

    Science.gov (United States)

    Viney, R; Gommersall, L; Zeif, J; Hayne, D; Shah, Z H; Doherty, A

    2009-07-01

    Radical retropubic prostatectomy (RRP) performed laparoscopically is a popular treatment with curative intent for organ-confined prostate cancer. After surgery, prostate specific antigen (PSA) levels drop to low levels which can be measured with ultrasensitive assays. This has been described in the literature for open RRP but not for laparoscopic RRP. This paper describes PSA changes in the first 300 consecutive patients undergoing non-robotic laparoscopic RRP by a single surgeon. To use ultrasensitive PSA (uPSA) assays to measure a PSA nadir in patients having laparoscopic radical prostatectomy below levels recorded by standard assays. The aim was to use uPSA nadir at 3 months' post-prostatectomy as an early surrogate end-point of oncological outcome. In so doing, laparoscopic oncological outcomes could then be compared with published results from other open radical prostatectomy series with similar end-points. Furthermore, this end-point could be used in the assessment of the surgeon's learning curve. Prospective, comprehensive, demographic, clinical, biochemical and operative data were collected from all patients undergoing non-robotic laparoscopic RRP. We present data from the first 300 consecutive patients undergoing laparoscopic RRP by a single surgeon. uPSA was measured every 3 months post surgery. Median follow-up was 29 months (minimum 3 months). The likelihood of reaching a uPSA of bench-marking performance. With experience, a surgeon can achieve in excess of an 80% chance of obtaining a uPSA nadir of < or = 0.01 ng/ml at 3 months after laparoscopic RRP for a British population. This is equivalent to most published open series.

  7. Lanthanide(III) complexes with tridentate Schiff base ligand ...

    African Journals Online (AJOL)

    The X-ray study reveals isotopic Nd/Sm binuclear structures were each metal ion is nine-coordinated in the same fashion. Both metal centers have distorted tricapped trigonal prism geometry, with the Schiff base acting as tridentate ligand. The DPPH· radical scavenging effects of the Schiff base ligand and its Ln(III) ...

  8. Evaluating tactile feedback in robotic surgery for potential clinical application using an animal model.

    Science.gov (United States)

    Wottawa, Christopher R; Genovese, Bradley; Nowroozi, Bryan N; Hart, Steven D; Bisley, James W; Grundfest, Warren S; Dutson, Erik P

    2016-08-01

    The aims of this study were to evaluate (1) grasping forces with the application of a tactile feedback system in vivo and (2) the incidence of tissue damage incurred during robotic tissue manipulation. Robotic-assisted minimally invasive surgery has been shown to be beneficial in a variety of surgical specialties, particularly radical prostatectomy. This innovative surgical tool offers advantages over traditional laparoscopic techniques, such as improved wrist-like maneuverability, stereoscopic video displays, and scaling of surgical gestures to increase precision. A widely cited disadvantage associated with robotic systems is the absence of tactile feedback. Nineteen subjects were categorized into two groups: 5 experts (six or more robotic cases) and 14 novices (five cases or less). The subjects used the da Vinci with integrated tactile feedback to run porcine bowel in the following conditions: (T1: deactivated tactile feedback; T2: activated tactile feedback; and T3: deactivated tactile feedback). The grasping force, incidence of tissue damage, and the correlation of grasping force and tissue damage were analyzed. Tissue damage was evaluated both grossly and histologically by a pathologist blinded to the sample. Tactile feedback resulted in significantly decreased grasping forces for both experts and novices (P system was deactivated (P > 0.05 in all subjects). The in vivo application of integrated tactile feedback in the robotic system demonstrates significantly reduced grasping forces, resulting in significantly less tissue damage. This tactile feedback system may improve surgical outcomes and broaden the use of robotic-assisted minimally invasive surgery.

  9. Generic robot architecture

    Science.gov (United States)

    Bruemmer, David J [Idaho Falls, ID; Few, Douglas A [Idaho Falls, ID

    2010-09-21

    The present invention provides methods, computer readable media, and apparatuses for a generic robot architecture providing a framework that is easily portable to a variety of robot platforms and is configured to provide hardware abstractions, abstractions for generic robot attributes, environment abstractions, and robot behaviors. The generic robot architecture includes a hardware abstraction level and a robot abstraction level. The hardware abstraction level is configured for developing hardware abstractions that define, monitor, and control hardware modules available on a robot platform. The robot abstraction level is configured for defining robot attributes and provides a software framework for building robot behaviors from the robot attributes. Each of the robot attributes includes hardware information from at least one hardware abstraction. In addition, each robot attribute is configured to substantially isolate the robot behaviors from the at least one hardware abstraction.

  10. Molecular Robots Obeying Asimov's Three Laws of Robotics.

    Science.gov (United States)

    Kaminka, Gal A; Spokoini-Stern, Rachel; Amir, Yaniv; Agmon, Noa; Bachelet, Ido

    2017-01-01

    Asimov's three laws of robotics, which were shaped in the literary work of Isaac Asimov (1920-1992) and others, define a crucial code of behavior that fictional autonomous robots must obey as a condition for their integration into human society. While, general implementation of these laws in robots is widely considered impractical, limited-scope versions have been demonstrated and have proven useful in spurring scientific debate on aspects of safety and autonomy in robots and intelligent systems. In this work, we use Asimov's laws to examine these notions in molecular robots fabricated from DNA origami. We successfully programmed these robots to obey, by means of interactions between individual robots in a large population, an appropriately scoped variant of Asimov's laws, and even emulate the key scenario from Asimov's story "Runaround," in which a fictional robot gets into trouble despite adhering to the laws. Our findings show that abstract, complex notions can be encoded and implemented at the molecular scale, when we understand robots on this scale on the basis of their interactions.

  11. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    Science.gov (United States)

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  12. Colias: An Autonomous Micro Robot for Swarm Robotic Applications

    Directory of Open Access Journals (Sweden)

    Farshad Arvin

    2014-07-01

    Full Text Available Robotic swarms that take inspiration from nature are becoming a fascinating topic for multi-robot researchers. The aim is to control a large number of simple robots in order to solve common complex tasks. Due to the hardware complexities and cost of robot platforms, current research in swarm robotics is mostly performed by simulation software. The simulation of large numbers of these robots in robotic swarm applications is extremely complex and often inaccurate due to the poor modelling of external conditions. In this paper, we present the design of a low-cost, open-platform, autonomous micro-robot (Colias for robotic swarm applications. Colias employs a circular platform with a diameter of 4 cm. It has a maximum speed of 35 cm/s which enables it to be used in swarm scenarios very quickly over large arenas. Long-range infrared modules with an adjustable output power allow the robot to communicate with its direct neighbours at a range of 0.5 cm to 2 m. Colias has been designed as a complete platform with supporting software development tools for robotics education and research. It has been tested in both individual and swarm scenarios, and the observed results demonstrate its feasibility for use as a micro-sized mobile robot and as a low-cost platform for robot swarm applications.

  13. Risk of port-site metastases in pelvic cancers after robotic surgery.

    Science.gov (United States)

    Seror, J; Bats, A-S; Bensaïd, C; Douay-Hauser, N; Ngo, C; Lécuru, F

    2015-04-01

    To assess the risk of occurrence of port-site metastases after robotic surgery for pelvic cancer. Retrospective study from June 2007 to March 2013 of patients with gynecologic cancer who underwent robot-assisted surgery. We collected preoperative data, including characteristics of patients and FIGO stage, intraoperative data (surgery performed, number of ports), and postoperative data (occurrence of metastases, occurrence of port-site metastases). 115 patients were included in the study: 61 with endometrial cancer, 50 with cervical cancer and 4 with ovarian cancer. The surgical procedures performed were: hysterectomy with bilateral salpingo-oophorectomy, radical hysterectomy, pelvic lymphadenectomy, para-aortic lymphadenectomy and omentectomy. All surgical procedures required the introduction of 4 ports, 3 for the robot and 1 for the assistant. With a mean follow-up of 504.4 days (507.7 days for endometrial cancer, 479.5 days for cervical cancer, and 511.3 for ovarian cancer), we observed 9 recurrences but no port-site metastasis. No port-site metastasis has occurred in our series. However, larger, prospective and randomized works are needed to formally conclude. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Heat loss and fluid leakage tests of the ROSA-III facility

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Shiba, Masayoshi

    1981-12-01

    The report presents characteristic test results about the steady state heat loss, one of the inherent characteristics of the ROSA-III test facility. The steady state heat loss tests were conducted at five different temperature conditions between 111 0 C and 290 0 C . Net heat loss rates were obtained by estimating the electric power supplied to the core, heat input from the recirculation pumps and steam leakage rate. The heat loss characteristics have important contribution to analyses of the ROSA-III small break tests. A following simple relation was obtained between the net heat loss rate Q*sub(HL) (kJ/s) (*: radical) of the ROSA-III facility and the temperature difference ΔT ( 0 C) between the fluid temperature of the system and the room temperature, Q*sub(HL) = 0.56 x ΔT. (*: radical) And the steam leak flow at normal operating condition of the ROSA-III test, (P = 7.2 MPa) was obtained as 8.9 x 10 -3 kg/s and corresponding steam leakage energy as 10.5 kJ/s. The heat input from the recirculation pumps was indirectly estimated under a constant speed by assuming the heat input was equal to the brake horce power of the pumps. (author)

  15. Completely Isolated Retroperitoneal Enteric Duplication Cyst with Adenocarcinoma Transformation Managed with Robotic Radical Nephrectomy

    OpenAIRE

    Faraj, Kassem; Edwards, Luke; Gupta, Alia; Seifman, Brian

    2017-01-01

    Abstract Background: Enteric duplication cysts are congenital malformations that typically affect children in infancy, but can also affect adults. Rarely, these cysts can be complicated by malignancy. We present the first case of retroperitoneal duplication cyst that was complicated by malignancy transformation and managed by robot-assisted excision. Case presentation: A 64-year-old female with a history of a left-sided renal cyst presented with a 4-month history of abdominal pain and fatigue...

  16. Robotic retroperitoneal partial nephrectomy: a step-by-step guide.

    Science.gov (United States)

    Ghani, Khurshid R; Porter, James; Menon, Mani; Rogers, Craig

    2014-08-01

    To describe a step-by-step guide for successful implementation of the retroperitoneal approach to robotic partial nephrectomy (RPN) PATIENTS AND METHODS: The patient is placed in the flank position and the table fully flexed to increase the space between the 12th rib and iliac crest. Access to the retroperitoneal space is obtained using a balloon-dilating device. Ports include a 12-mm camera port, two 8-mm robotic ports and a 12-mm assistant port placed in the anterior axillary line cephalad to the anterior superior iliac spine, and 7-8 cm caudal to the ipsilateral robotic port. Positioning and port placement strategies for successful technique include: (i) Docking robot directly over the patient's head parallel to the spine; (ii) incision for camera port ≈1.9 cm (1 fingerbreadth) above the iliac crest, lateral to the triangle of Petit; (iii) Seldinger technique insertion of kidney-shaped balloon dilator into retroperitoneal space; (iv) Maximising distance between all ports; (v) Ensuring camera arm is placed in the outer part of the 'sweet spot'. The retroperitoneal approach to RPN permits direct access to the renal hilum, no need for bowel mobilisation and excellent visualisation of posteriorly located tumours. © 2014 The Authors. BJU International © 2014 BJU International.

  17. Micro intelligence robot

    International Nuclear Information System (INIS)

    Jeon, Yon Ho

    1991-07-01

    This book gives descriptions of micro robot about conception of robots and micro robot, match rules of conference of micro robots, search methods of mazes, and future and prospect of robots. It also explains making and design of 8 beat robot like making technique, software, sensor board circuit, and stepping motor catalog, speedy 3, Mr. Black and Mr. White, making and design of 16 beat robot, such as micro robot artist, Jerry 2 and magic art of shortening distances algorithm of robot simulation.

  18. Modelling of industrial robot in LabView Robotics

    Science.gov (United States)

    Banas, W.; Cwikła, G.; Foit, K.; Gwiazda, A.; Monica, Z.; Sekala, A.

    2017-08-01

    Currently can find many models of industrial systems including robots. These models differ from each other not only by the accuracy representation parameters, but the representation range. For example, CAD models describe the geometry of the robot and some even designate a mass parameters as mass, center of gravity, moment of inertia, etc. These models are used in the design of robotic lines and sockets. Also systems for off-line programming use these models and many of them can be exported to CAD. It is important to note that models for off-line programming describe not only the geometry but contain the information necessary to create a program for the robot. Exports from CAD to off-line programming system requires additional information. These models are used for static determination of reachability points, and testing collision. It’s enough to generate a program for the robot, and even check the interaction of elements of the production line, or robotic cell. Mathematical models allow robots to study the properties of kinematic and dynamic of robot movement. In these models the geometry is not so important, so are used only selected parameters such as the length of the robot arm, the center of gravity, moment of inertia. These parameters are introduced into the equations of motion of the robot and motion parameters are determined.

  19. Towards Sociable Robots

    DEFF Research Database (Denmark)

    Ngo, Trung Dung

    This thesis studies aspects of self-sufficient energy (energy autonomy) for truly autonomous robots and towards sociable robots. Over sixty years of history of robotics through three developmental ages containing single robot, multi-robot systems, and social (sociable) robots, the main objective...... of roboticists mostly focuses on how to make a robotic system function autonomously and further, socially. However, such approaches mostly emphasize behavioural autonomy, rather than energy autonomy which is the key factor for not only any living machine, but for life on the earth. Consequently, self......-sufficient energy is one of the challenges for not only single robot or multi-robot systems, but also social and sociable robots. This thesis is to deal with energy autonomy for multi-robot systems through energy sharing (trophallaxis) in which each robot is equipped with two capabilities: self-refueling energy...

  20. Biomass feeds vegetarian robot; Biomassa voedt vegetarische robot

    Energy Technology Data Exchange (ETDEWEB)

    Van den Brandt, M. [Office for Science and Technology, Embassy of the Kingdom of the Netherlands, Washington (United States)

    2009-09-15

    This brief article addresses the EATR robot (Energetically Autonomous Tactical Robot) that was developed by Cyclone Power and uses biomass as primary source of energy for propulsion. [Dutch] Een kort artikel over de door Cyclone Power ontwikkelde EATR-robot (Energetically Autonomous Tactical Robot) die voor de voortdrijving biomassa gebruikt als primaire energiebron.

  1. Robot Futures

    DEFF Research Database (Denmark)

    Christoffersen, Anja; Grindsted Nielsen, Sally; Jochum, Elizabeth Ann

    Robots are increasingly used in health care settings, e.g., as homecare assistants and personal companions. One challenge for personal robots in the home is acceptance. We describe an innovative approach to influencing the acceptance of care robots using theatrical performance. Live performance...... is a useful testbed for developing and evaluating what makes robots expressive; it is also a useful platform for designing robot behaviors and dialogue that result in believable characters. Therefore theatre is a valuable testbed for studying human-robot interaction (HRI). We investigate how audiences...... perceive social robots interacting with humans in a future care scenario through a scripted performance. We discuss our methods and initial findings, and outline future work....

  2. Soft Robotics Week

    CERN Document Server

    Rossiter, Jonathan; Iida, Fumiya; Cianchetti, Matteo; Margheri, Laura

    2017-01-01

    This book offers a comprehensive, timely snapshot of current research, technologies and applications of soft robotics. The different chapters, written by international experts across multiple fields of soft robotics, cover innovative systems and technologies for soft robot legged locomotion, soft robot manipulation, underwater soft robotics, biomimetic soft robotic platforms, plant-inspired soft robots, flying soft robots, soft robotics in surgery, as well as methods for their modeling and control. Based on the results of the second edition of the Soft Robotics Week, held on April 25 – 30, 2016, in Livorno, Italy, the book reports on the major research lines and novel technologies presented and discussed during the event.

  3. Towards Versatile Robots Through Open Heterogeneous Modular Robots

    OpenAIRE

    Lyder, Andreas

    2010-01-01

    Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a ...

  4. Robotic architectures

    CSIR Research Space (South Africa)

    Mtshali, M

    2010-01-01

    Full Text Available In the development of mobile robotic systems, a robotic architecture plays a crucial role in interconnecting all the sub-systems and controlling the system. The design of robotic architectures for mobile autonomous robots is a challenging...

  5. Reductive and oxidative degradation of iopamidol, iodinated X-ray contrast media, by Fe(III)-oxalate under UV and visible light treatment.

    Science.gov (United States)

    Zhao, Cen; Arroyo-Mora, Luis E; DeCaprio, Anthony P; Sharma, Virender K; Dionysiou, Dionysios D; O'Shea, Kevin E

    2014-12-15

    Iopamidol, widely employed as iodinated X-ray contrast media (ICM), is readily degraded in a Fe(III)-oxalate photochemical system under UV (350 nm) and visible light (450 nm) irradiation. The degradation is nicely modeled by pseudo first order kinetics. The rates of hydroxyl radical (OH) production for Fe(III)-oxalate/H2O2/UV (350 nm) and Fe(III)-oxalate/H2O2/visible (450 nm) systems were 1.19 ± 0.12 and 0.30 ± 0.01 μM/min, respectively. The steady-state concentration of hydroxyl radical (OH) for the Fe(III)-oxalate/H2O2/UV (350 nm) conditions was 10.88 ± 1.13 × 10(-14) M and 2.7 ± 0.1 × 10(-14) M for the Fe(III)-oxalate/H2O2/visible (450 nm). The rate of superoxide anion radical (O2(-)) production under Fe(III)-oxalate/H2O2/UV (350 nm) was 0.19 ± 0.02 μM/min with a steady-state concentration of 5.43 ± 0.473 × 10(-10) M. Detailed product studies using liquid chromatography coupled to Q-TOF/MS demonstrate both reduction (multiple dehalogenations) and oxidation (aromatic ring and side chains) contribute to the degradation pathways. The reduction processes appear to be initiated by the carbon dioxide anion radical (CO2(-)) while oxidation processes are consistent with OH initiated reaction pathways. Unlike most advanced oxidation processes the Fe(III)-oxalate/H2O2/photochemical system can initiate to both reductive and oxidative degradation processes. The observed reductive dehalogenation is an attractive remediation strategy for halogenated organic compounds as the process can dramatically reduce the formation of the problematic disinfection by-products often associated with oxidative treatment processes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Development and validation of surgical training tool: cystectomy assessment and surgical evaluation (CASE) for robot-assisted radical cystectomy for men.

    Science.gov (United States)

    Hussein, Ahmed A; Sexton, Kevin J; May, Paul R; Meng, Maxwell V; Hosseini, Abolfazl; Eun, Daniel D; Daneshmand, Siamak; Bochner, Bernard H; Peabody, James O; Abaza, Ronney; Skinner, Eila C; Hautmann, Richard E; Guru, Khurshid A

    2018-04-13

    We aimed to develop a structured scoring tool: cystectomy assessment and surgical evaluation (CASE) that objectively measures and quantifies performance during robot-assisted radical cystectomy (RARC) for men. A multinational 10-surgeon expert panel collaborated towards development and validation of CASE. The critical steps of RARC in men were deconstructed into nine key domains, each assessed by five anchors. Content validation was done utilizing the Delphi methodology. Each anchor was assessed in terms of context, score concordance, and clarity. The content validity index (CVI) was calculated for each aspect. A CVI ≥ 0.75 represented consensus, and this statement was removed from the next round. This process was repeated until consensus was achieved for all statements. CASE was used to assess de-identified videos of RARC to determine reliability and construct validity. Linearly weighted percent agreement was used to assess inter-rater reliability (IRR). A logit model for odds ratio (OR) was used to assess construct validation. The expert panel reached consensus on CASE after four rounds. The final eight domains of the CASE included: pelvic lymph node dissection, development of the peri-ureteral space, lateral pelvic space, anterior rectal space, control of the vascular pedicle, anterior vesical space, control of the dorsal venous complex, and apical dissection. IRR > 0.6 was achieved for all eight domains. Experts outperformed trainees across all domains. We developed and validated a reliable structured, procedure-specific tool for objective evaluation of surgical performance during RARC. CASE may help differentiate novice from expert performances.

  7. Soft Robotics.

    Science.gov (United States)

    Whitesides, George M

    2018-04-09

    This description of "soft robotics" is not intended to be a conventional review, in the sense of a comprehensive technical summary of a developing field. Rather, its objective is to describe soft robotics as a new field-one that offers opportunities to chemists and materials scientists who like to make "things" and to work with macroscopic objects that move and exert force. It will give one (personal) view of what soft actuators and robots are, and how this class of soft devices fits into the more highly developed field of conventional "hard" robotics. It will also suggest how and why soft robotics is more than simply a minor technical "tweak" on hard robotics and propose a unique role for chemistry, and materials science, in this field. Soft robotics is, at its core, intellectually and technologically different from hard robotics, both because it has different objectives and uses and because it relies on the properties of materials to assume many of the roles played by sensors, actuators, and controllers in hard robotics. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A Model Study of the Photochemical Fate of As(III in Paddy-Water

    Directory of Open Access Journals (Sweden)

    Luca Carena

    2017-03-01

    Full Text Available The APEX (Aqueous Photochemistry of Environmentally-occurring Xenobiotics software previously developed by one of us was used to model the photochemistry of As(III in paddy-field water, allowing a comparison with biotic processes. The model included key paddy-water variables, such as the shielding effect of the rice canopy on incident sunlight and its monthly variations, water pH, and the photochemical parameters of the chromophoric dissolved organic matter (CDOM occurring in paddy fields. The half-life times (t1/2 of As(III photooxidation to As(V would be ~20–30 days in May. In contrast, the photochemical oxidation of As(III would be much slower in June and July due to rice-canopy shading of radiation because of plant growth, despite higher sunlight irradiance. At pH < 8 the photooxidation of As(III would mainly be accounted for by reaction with transient species produced by irradiated CDOM (here represented by the excited triplet states 3CDOM*, neglecting the possibly more important reactions with poorly known species such as the phenoxy radicals and, to a lesser extent, with the hydroxyl radicals (HO•. However, the carbonate radicals (CO3•− could be key photooxidants at pH > 8.5 provided that the paddy-water 3CDOM* is sufficiently reactive toward the oxidation of CO32−. In particular, if paddy-water 3CDOM* oxidizes the carbonate anion with a second-order reaction rate constant near (or higher than 106 M−1·s−1, the photooxidation of As(III could be quite fast at pH > 8.5. Such pH conditions can be produced by elevated photosynthetic activity that consumes dissolved CO2.

  9. The Efficacy and Utilisation of Preoperative Magnetic Resonance Imaging in Robot-assisted Radical Prostatectomy: Does it Change the Surgical Dissection Plan? A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Tavukçu

    2015-06-01

    Full Text Available Purpose: We investigated the effect of prostate magnetic resonance imaging (MRI on the dissection plan of the neurovascular bundle and the oncological results of our patients who underwent robotic radical prostatectomy operation. Materials and Methods: We prospectively evaluated 30 consecutive patients, 15 of whom had prostate MRI before the operation, and 15 of whom did not. With the findings of MRI, the dissection plan was changed as intrafascial, interfascial, and extrafascial technique in the MRI group. Two groups were compared in terms of age, prostate-specific antigen (PSA, and Gleason scores (GSs. Surgical margin status was also checked with the final pathology. Results: There was no significant difference between the two groups in terms of age, PSA, biopsy GS, and final pathological GS. MRI changed the initial surgical plan to a nerve-sparing technique in 7 of the 15 patients. Only one patient in the MRI group had a positive surgical margin on bladder neck. MRI was confirmed as the primary tumour localisation in the final pathology in 93.3% of patients. Conclusion: Preoperative prostate MRI influenced the decision to carry out a nerve-sparing technique in 46% of the patients in our study; however, the change to a nerve-sparing technique did not seem to compromise the surgical margin positivity.

  10. Moessbauer effect study of iron(III)-inidazolidine nitroxyl-free radical ligand complex

    Energy Technology Data Exchange (ETDEWEB)

    Mulaba, A. [Technikon Witwatersrand, Metallurgy Department (South Africa); Kiremire, E. [University of the Witwatersrand, Chemistry Department (South Africa); Pollak, H. [University of the Witwatersrand, Physics Department (South Africa); Boeyens, J. [University of the Witwatersrand, Chemistry Department (South Africa)

    1999-09-15

    A new complex, [Fe(acac)L{sub 2}], bearing inidazolidine nitroxyl-free radical ligand (L{sup -}) was recently synthesised for biological studies. It proved to be biologically active against African sleeping sickness, plasmodium falciparum (malaria), leishmaniasis and chaga disease causative agents. Three ESR well resolved peaks indicated the presence of a free (unpaired) and chemically active electron in the complex. The structural complex ferric iron was found at the centre of two electric gradient whose the biggest is suggested to be initiated by the unpaired charge. No distinction between different cis isomers could be made.

  11. Moessbauer effect study of iron(III)-inidazolidine nitroxyl-free radical ligand complex

    International Nuclear Information System (INIS)

    Mulaba, A.; Kiremire, E.; Pollak, H.; Boeyens, J.

    1999-01-01

    A new complex, [Fe(acac)L 2 ], bearing inidazolidine nitroxyl-free radical ligand (L - ) was recently synthesised for biological studies. It proved to be biologically active against African sleeping sickness, plasmodium falciparum (malaria), leishmaniasis and chaga disease causative agents. Three ESR well resolved peaks indicated the presence of a free (unpaired) and chemically active electron in the complex. The structural complex ferric iron was found at the centre of two electric gradient whose the biggest is suggested to be initiated by the unpaired charge. No distinction between different cis isomers could be made

  12. Exploiting Child-Robot Aesthetic Interaction for a Social Robot

    OpenAIRE

    Lee, Jae-Joon; Kim, Dae-Won; Kang, Bo-Yeong

    2012-01-01

    A social robot interacts and communicates with humans by using the embodied knowledge gained from interactions with its social environment. In recent years, emotion has emerged as a popular concept for designing social robots. Several studies on social robots reported an increase in robot sociability through emotional imitative interactions between the robot and humans. In this paper conventional emotional interactions are extended by exploiting the aesthetic theories that the sociability of ...

  13. Locally advanced breast cancer (stage III and stage IV)

    International Nuclear Information System (INIS)

    Baracat, F.F.; Grabert, H.; Lima, G.R. de; Pontes, M.; Ferraro, O.; Santana, A.; Brook, E.S.

    1987-01-01

    The results concerning to the treatment of 193 patients with locally advanced breast cancer-stage III and stage IV are analysed. All the patients were treated with radical radiotherapy plus total mastectomy about 6 weeks later; 53 pacients received also chemotherapy (CMF - 12 courses) and 52 were oophorectomized. (M.A.C) [pt

  14. Evolutionary robotics

    Indian Academy of Sciences (India)

    In evolutionary robotics, a suitable robot control system is developed automatically through evolution due to the interactions between the robot and its environment. It is a complicated task, as the robot and the environment constitute a highly dynamical system. Several methods have been tried by various investigators to ...

  15. Reduction reactions of water soluble cyano-cobalt(III)-porphyrins: Metal versus ligand centered processes

    International Nuclear Information System (INIS)

    Mosseri, S.; Neta, P.; Harriman, A.; Hambright, P.

    1990-01-01

    Reduction reactions of dicyano-cobalt(III)-porphyrins [potential in vivo cyanide scavenger drugs] were studied by radiolytic and electrochemical methods using the water soluble tetrakis(4-sulfonatophenyl)porphyrin (TPPS) and tetrakis(N-methyl-4-pyridyl)porphyrin (TMPyP). For [(CN)2CoIIITPPS]-, reduction occurs stepwise to the CoII, CoI, and finally to the phlorin anion. This behavior is similar to that of the cobalt porphyrins in the absence of cyanide, except that the cyanide ligand shifts the reduction potentials to much more negative values. On the other hand, under radiolytic conditions, [(CN)2CoIIITMPyP]- is reduced on the porphyrin macrocycle by one electron to give the CoIII pi-radical anion, which disproportionates into the initial complex and the two-electron ring reduced CoIII phlorin. The radical anion is also formed by intramolecular electron transfer subsequent to the reaction of CoIITMPyP and cyanide. The results are compared with the chemistry of Vitamin B-12

  16. Interactive Exploration Robots: Human-Robotic Collaboration and Interactions

    Science.gov (United States)

    Fong, Terry

    2017-01-01

    For decades, NASA has employed different operational approaches for human and robotic missions. Human spaceflight missions to the Moon and in low Earth orbit have relied upon near-continuous communication with minimal time delays. During these missions, astronauts and mission control communicate interactively to perform tasks and resolve problems in real-time. In contrast, deep-space robotic missions are designed for operations in the presence of significant communication delay - from tens of minutes to hours. Consequently, robotic missions typically employ meticulously scripted and validated command sequences that are intermittently uplinked to the robot for independent execution over long periods. Over the next few years, however, we will see increasing use of robots that blend these two operational approaches. These interactive exploration robots will be remotely operated by humans on Earth or from a spacecraft. These robots will be used to support astronauts on the International Space Station (ISS), to conduct new missions to the Moon, and potentially to enable remote exploration of planetary surfaces in real-time. In this talk, I will discuss the technical challenges associated with building and operating robots in this manner, along with lessons learned from research conducted with the ISS and in the field.

  17. ROBOT-ASSISTED LAPAROSCOPIC PROSTATECTOMY: OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    S. N. Nesterov

    2014-08-01

    Full Text Available Background. Retropubic radical prostatectomy (RPE is now the gold standard of treatment for locally advanced prostate cancer (PC. However, robot-assisted RPE procedures using the da Vinci system are finding increasing acceptance.Materials and methods. The authors conducted a prospective study of 60 robot-assisted prostatectomies made at the Clinic of Urology, N.I. Pirogov National Medical Surgical Center, in the period January 2009 to December 2010.Results. The duration of an operation averaged 230 min; the average amount of blood loss was 200 ml. The mean duration of postoperative analgesia was 2,7 days. That of urinary catheterization was 8.5 days. A normal postoperative course was noted in most cases (88,4 %. Seven patients were found to have 8 (13,3 % mild and moderate complications. A pathohistological study revealed a positive surgical margin of resection in 21,7 % of the patients, extracapsular tumor growth in 21,7 %, and seminal vesicle invasion in 23,3 %. Tumor-affected regional lymph nodes were detected in 1 (1,7 % patient. In our observed series, 82 and 93 % of the subjects completely retained urine after 6 and 12 moths, respectively. Throughout the follow-up, erectile function recovered in 7 of the 15 patients undergoing a nerve-sparing surgical procedure.Conclusion. Postoperative results in our series of interventions are comparable to those obtained in the studies by Russian and foreign colleagues at the early stage of mastering this procedure. By considering a few observations, it is today difficult to say that our study is valid in the context of evidence-based medicine. Estimation of the benefits of robot-assisted laparoscopic prostatectomy calls for long-term multicenter randomized trials.

  18. COMPARATIVE STUDY OF DEGRADATION OF ISOPROTURON (3-(4-isopropylphenyl-1,1dimethylurea PHOTOINDUCED BY FE(III AND FE(III-PHOTOINDUCED SONOCHEMICAL IN AQUEOUS SOLUTION

    Directory of Open Access Journals (Sweden)

    S Azizi

    2014-05-01

    Full Text Available The degradation of isoproturon 3-(4-isopropylphenyl-1,1dimethylurea photoinduced by Fe(III in aqueous solution has been investigated. The rate of degradation depends on the concentration of Fe(OH2+, the most photoreactive species in terms of .OH radical formation. These .OH radicals are able to degrade isoproturon until total mineralisation. The formation  of  Fe(II in the irradiated solution was monitored. The sonophotochemical degradation of isoproturon has been found to be dependent on the intensity of sonication. The combination of ultrasound and photochemistry has been used to degrade an aqueous solution of Isoproturon (IP. The degradation of IP in aqueous solution was investigated under sonolysis at         500 kHz and in the presence of Fe(III, as well as under simultaneous sonolysis and photoinduced Fe(III. Coupling photolysis with ultrasound for degradation of IP has been developed. The photosonochemical decomposition rate constant is greater than the additive rate constants of the two processes. Degradation products were analysed by CG/MS performed in the electron-impact (EI mode, at 70 eV potential using full scan mode. Degradation photoproducts were identified and a mechanism of degradation is proposed for two processes.

  19. ROBOT LITERACY AN APPROACH FOR SHARING SOCIETY WITH INTELLIGENT ROBOTS

    Directory of Open Access Journals (Sweden)

    Hidetsugu Suto

    2013-12-01

    Full Text Available A novel concept of media education called “robot literacy” is proposed. Here, robot literacy refers to the means of forming an appropriate relationship with intelligent robots. It can be considered a kind of media literacy. People who were born after the Internet age can be considered “digital natives” who have new morals and values and behave differently than previous generations in Internet societies. This can cause various problems among different generations. Thus, the necessity of media literacy education is increasing. Internet technologies, as well as robotics technologies are growing rapidly, and people who are born after the “home robot age,” whom the author calls “robot natives,” will be expected to have a certain degree of “robot literacy.” In this paper, the concept of robot literacy is defined and an approach to robot literacy education is discussed.

  20. Robotic buildings(s)

    NARCIS (Netherlands)

    Bier, H.H.

    2014-01-01

    Technological and conceptual advances in fields such as artificial intelligence, robotics, and material science have enabled robotic building to be in the last decade prototypically implemented. In this context, robotic building implies both physically built robotic environments and robotically

  1. Constrained Quadratic Programming and Neurodynamics-Based Solver for Energy Optimization of Biped Walking Robots

    Directory of Open Access Journals (Sweden)

    Liyang Wang

    2017-01-01

    Full Text Available The application of biped robots is always trapped by their high energy consumption. This paper makes a contribution by optimizing the joint torques to decrease the energy consumption without changing the biped gaits. In this work, a constrained quadratic programming (QP problem for energy optimization is formulated. A neurodynamics-based solver is presented to solve the QP problem. Differing from the existing literatures, the proposed neurodynamics-based energy optimization (NEO strategy minimizes the energy consumption and guarantees the following three important constraints simultaneously: (i the force-moment equilibrium equation of biped robots, (ii frictions applied by each leg on the ground to hold the biped robot without slippage and tipping over, and (iii physical limits of the motors. Simulations demonstrate that the proposed strategy is effective for energy-efficient biped walking.

  2. Cloud Robotics Platforms

    Directory of Open Access Journals (Sweden)

    Busra Koken

    2015-01-01

    Full Text Available Cloud robotics is a rapidly evolving field that allows robots to offload computation-intensive and storage-intensive jobs into the cloud. Robots are limited in terms of computational capacity, memory and storage. Cloud provides unlimited computation power, memory, storage and especially collaboration opportunity. Cloud-enabled robots are divided into two categories as standalone and networked robots. This article surveys cloud robotic platforms, standalone and networked robotic works such as grasping, simultaneous localization and mapping (SLAM and monitoring.

  3. Distributed Robotics Education

    DEFF Research Database (Denmark)

    Lund, Henrik Hautop; Pagliarini, Luigi

    2011-01-01

    Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept of a distribu......Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept...... to be changed, related to multirobot control and human-robot interaction control from virtual to physical representation. The proposed system is valuable for bringing a vast number of issues into education – such as parallel programming, distribution, communication protocols, master dependency, connectivity...

  4. Robot Mechanisms

    CERN Document Server

    Lenarcic, Jadran; Stanišić, Michael M

    2013-01-01

    This book provides a comprehensive introduction to the area of robot mechanisms, primarily considering industrial manipulators and humanoid arms. The book is intended for both teaching and self-study. Emphasis is given to the fundamentals of kinematic analysis and the design of robot mechanisms. The coverage of topics is untypical. The focus is on robot kinematics. The book creates a balance between theoretical and practical aspects in the development and application of robot mechanisms, and includes the latest achievements and trends in robot science and technology.

  5. Robots de servicio

    Directory of Open Access Journals (Sweden)

    Rafael Aracil

    2008-04-01

    Full Text Available Resumen: El término Robots de Servicio apareció a finales de los años 80 como una necesidad de desarrollar máquinas y sistemas capaces de trabajar en entornos diferentes a los fabriles. Los Robots de Servicio tenían que poder trabajar en entornos noestructurados, en condiciones ambientales cambiantes y con una estrecha interacción con los humanos. En 1995 fue creado por la IEEE Robotics and Automation Society, el Technical Committee on Service Robots, y este comité definió en el año 2000 las áreas de aplicación de los Robots de Servicios, que se pueden dividir en dos grandes grupos: 1 sectores productivos no manufactureros tales como edificación, agricultura, naval, minería, medicina, etc. y 2 sectores de servicios propiamente dichos: asistencia personal, limpieza, vigilancia, educación, entretenimiento, etc. En este trabajo se hace una breve revisión de los principales conceptos y aplicaciones de los robots de servicio. Palabras clave: Robots de servicio, robots autónomos, robots de exteriores, robots de educación y entretenimiento, robots caminantes y escaladores, robots humanoides

  6. Filigree Robotics

    DEFF Research Database (Denmark)

    Tamke, Martin; Evers, Henrik Leander; Clausen Nørgaard, Esben

    2016-01-01

    Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture.......Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture....

  7. Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)

    1999-05-15

    Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)

  8. Ferrous-activated persulfate oxidation of arsenic(III) and diuron in aquatic system.

    Science.gov (United States)

    Zhou, Lei; Zheng, Wei; Ji, Yuefei; Zhang, Jinfeng; Zeng, Chao; Zhang, Ya; Wang, Qi; Yang, Xi

    2013-12-15

    In situ chemical oxidation (ISCO) can be an effective technology for the remediation of soil and groundwater polluted by organic and inorganic contaminants. This study investigated the oxidation of arsenic(III) (As(III)) and diuron using ferrous activated persulfate-based ISCO. The results indicated that Fe(II)/persulfate oxidation could be an effective method to oxidize As(III) and diuron. Effects of pH, S2O8(2-) and Fe(II) amounts on the destruction of As(III) and diuron were examined in batch experiments. Acidic conditions favored the removal of As(III) and diuron. Four chelating agents, citric acid (CA), Na2S2O3, diethylene triamine pentaacetic acid (DTPA) and ethylene diamine tetraacetic acid disodium (EDTA-Na2) were used in attempt to maintain the quantity of ferrous ion in solution. In our experiments, CA and Na2S2O3 were found to be more effective than DTPA and EDTA-Na2. Our results also revealed a widely practical prospect of inorganic chelating agent Na2S2O3. Hydroxyl and sulfate radical were determined to play key roles in the oxidation process by using ethanol and tertiary butanol as molecular probes. Oxidation of As(III) yielded As(V) via the electron-transfer reaction. In the oxidation process of diuron, a stepwise nucleophilic substitution of chlorine by hydroxyl and a stepwise oxidation process of the methyl on the dimethylurea group by hydroxyl and sulfate radical were proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Robotics education

    International Nuclear Information System (INIS)

    Benton, O.

    1984-01-01

    Robotics education courses are rapidly spreading throughout the nation's colleges and universities. Engineering schools are offering robotics courses as part of their mechanical or manufacturing engineering degree program. Two year colleges are developing an Associate Degree in robotics. In addition to regular courses, colleges are offering seminars in robotics and related fields. These seminars draw excellent participation at costs running up to $200 per day for each participant. The last one drew 275 people from Texas to Virginia. Seminars are also offered by trade associations, private consulting firms, and robot vendors. IBM, for example, has the Robotic Assembly Institute in Boca Raton and charges about $1,000 per week for course. This is basically for owners of IBM robots. Education (and training) can be as short as one day or as long as two years. Here is the educational pattern that is developing now

  10. Free radical scavenging window of infertile patients with polycystic ovary syndrome: correlation with embryo quality.

    Science.gov (United States)

    Huang, Bo; Li, Zhou; Ren, Xinling; Ai, Jihui; Zhu, Lixia; Jin, Lei

    2017-06-01

    The activity of free radicals in follicular fluid was related to ovarian responsiveness, in vitro fertilization (IVF), and embryo transfer success rate. However, studies analyzing the relationship between the free radical scavenging capacity and embryo quality of infertile women with polycystic ovarian syndrome (PCOS) were lacking. The aim of this study was to evaluate the relationship between the free radical scavenging window of women with PCOS and their embryo quality. The free radical scavenging capacity of follicular fluid from women with PCOS was determined by a,a-diphenyl-b-picrylhydrazyl (DPPH), 2,2-azinobis (3-ethylbenzthiazoline-6-sulphonic acid) assay, superoxide radical, and reactive oxygen species (ROS) assay. In the DPPH and ROS assays, the follicular fluid from grades I and II embryos was significantly higher than the follicular fluid from grades III and IVembryos. The lower control limit of DPPH radical scavenging capacity and upper control limit of ROS level were 13.2% and 109.0 cps, respectively. The calculated lower control limit and upper control limit were further confirmed in the follicular fluid of embryos of all grades. These cut-off values of free radical scavenging activity of follicular fluid could assist embryologists in choosing the development of embryos in PCOS patients undergoing IVF.

  11. 4-(2-Tetrathiafulvalenyl-ethenyl)pyridine (TTF-CH=CH-Py) radical cation salts containing poly(beta-diketonate) rare earth complexes: synthesis, crystal structure, photoluminescent and magnetic properties.

    Science.gov (United States)

    Pointillart, Fabrice; Maury, Olivier; Le Gal, Yann; Golhen, Stéphane; Cador, Olivier; Ouahab, Lahcène

    2009-08-03

    The reactions between the redox-active 4-(2-tetrathiafulvalenyl-ethenyl)pyridine ligand (TTF-CH=CH-Py) and the tris(1,1,1,5,5,5-hexafluoroacetylacetonate)Ln(III) (Ln = La and Nd) lead to the formation of compounds with the formulas {[La(hfac)(5)][(TTF-CH=CH-Py(*+))](2)} (1), {[Nd(hfac)(4)(H(2)O)][(TTF-CH=CH-Py(*+))]}(2) (2), and {[Nd(hfac)(4)(H(2)O)][(TTF-CH=CH-Py(*+))]}(2)(H(2)O)(C(6)H(14))(0.5) (3) (hfac(-) = 1,1,1,5,5,5-hexafluoroacetylacetonate anion). These compounds have been characterized by single-crystal X-ray diffraction, optical, and magnetic measurements. Compounds 1, 2, and 3 crystallize in the monoclinic C2/c, triclinic P1, and monoclinic P2(1)/c space groups, respectively. La(III) adopts a tetradecahedral geometry, while Nd(III) stands in a distorted capped square antiprism one. In 1, the inorganic network is formed by the [La(hfac)(5)](2-) dianionic complexes, while it is formed by a pseudo-dimeric dianionic unit of formula {[Nd(hfac)(4)(H(2)O)](2)}(2-) in 2 and 3. In all crystal structures, the organic network is constituted by the TTF-CH=CH-Py(*+) radical cations. The inorganic and organic networks interact through intermolecular contacts between the pyridine moieties of the TTF-CH=CH-Py(*+) radical cations and the Ln(III) ions. The luminescence properties of the Nd(III) ions (9400 cm(-1)) and fluorescence band of the TTF-CH=CH-Py(*+) radical cations (10200 cm(-1)) have been observed and studied for compound 2. Complexes 2 and 3 are paramagnetic because of Nd(III) ions. Compound 2 is a paramagnetic luminescent TTF-radical-cation-based material. Resistivity measurements have also been performed on these materials.

  12. Hydroxyl-radical-induced oxidation of cyclic dipeptides: Reactions of free peptide radicals and their peroxyl radicals

    International Nuclear Information System (INIS)

    Mieden, O.J.

    1989-01-01

    In the course of this study investigations were carried out into the reactions of hydroxyl radicals and hydrogen atoms with cyclic dipeptides as well as the subsequent reactions of peptide radicals and their peroxyl radicals in aqueous solution. The radiolysis products formed in the absence and presence of oxygen or transient metal complexes were characterized and determined on a quantitative basis. The linking of information from product analyses to the kinetic data for transient species obtained by time-resolving UV/VIS and conductivity measurements (pulse radiolysis) as well as computer-assisted simulations of individual events during the reaction permitted an evaluation of the mechanisms underlying the various processes and an identification of interim products with short life-times, which did or did not belong to the group of radicals. Through the characterization of key reactions of radicals and peroxyl radicals of this substance class a major advance has been made towards a better understanding of the role of radicals in the peptide compound and the mechanisms involved in indirect radiation effects on long-chain peptides and proteins. (orig.) [de

  13. Robotic resections in hepatobiliary oncology - initial experience with Xi da Vinci system in India.

    Science.gov (United States)

    Chandarana, M; Patkar, S; Tamhankar, A; Garg, S; Bhandare, M; Goel, M

    2017-01-01

    Minimal invasive surgery has proven its advantages over open surgeries in the perioperative period. Food and Drug Administration approved da Vinci robot in 2000. The latest version, da Vinci Xi system has a mobile tower-based robot with several modifications to improve the functionality, versatility, and operative ease. None of the centers have reported exclusively on hepatobiliary oncology using the da Vinci Xi system. We report our initial experience. To study the feasibility, advantages, and discuss the operative technique of da Vinci Xi system in hepatobiliary oncology. Data were analyzed retrospectively from a prospectively maintained database from June 2015 to October 2016. Twenty-five patients with suspected or proven hepatobiliary malignancies were operated. Total robotic technique using da Vinci Xi system was used. Demographic details and perioperative outcomes were noted. Of the 25 surgeries, 14 patients had a suspected gallbladder malignancy, 11 patients had primary or metastatic liver tumor. Median age was 53 years. The average duration of surgery was 225 min with a median blood loss 150 ml. The median postoperative stay was 4 days. The median nodal yield for radical cholecystectomy was seven. Five patients required conversion. Two of these developed postoperative morbidity. Robotic surgery for hepatobiliary oncology is feasible and can be performed safely in experienced hands. Increasing experience in this field may equal or even prove advantageous over conventional or laparoscopic approach in future. A cautious approach with judicious patient selection is the key to establishing robotic surgery as a standard surgical approach.

  14. Feasibility of Muscle Synergy Outcomes in Clinics, Robotics, and Sports: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Juri Taborri

    2018-01-01

    Full Text Available In the last years, several studies have been focused on understanding how the central nervous system controls muscles to perform a specific motor task. Although it still remains an open question, muscle synergies have come to be an appealing theory to explain the modular organization of the central nervous system. Even though the neural encoding of muscle synergies remains controversial, a large number of papers demonstrated that muscle synergies are robust across different tested conditions, which are within a day, between days, within a single subject, and between subjects that have similar demographic characteristics. Thus, muscle synergy theory has been largely used in several research fields, such as clinics, robotics, and sports. The present systematical review aims at providing an overview on the applications of muscle synergy theory in clinics, robotics, and sports; in particular, the review is focused on the papers that provide tangible information for (i diagnosis or pathology assessment in clinics, (ii robot-control design in robotics, and (iii athletes’ performance assessment or training guidelines in sports.

  15. A radical approach to radical innovation

    NARCIS (Netherlands)

    D. Deichmann (Dirk); J.C.M. van den Ende (Jan)

    2014-01-01

    textabstractInnovation pays. Amazon, Apple, Facebook, Google – nearly every one of today’s most successful companies has a talent for developing radical new ideas. But how best to encourage radical initiative taking from employees, and does their previous success or failure at it play a role?

  16. Risk of recurrence in patients with colon cancer stage II and III

    DEFF Research Database (Denmark)

    Bockelman, C.; Engelmann, Bodil E.; Kaprio, T.

    2015-01-01

    Background. Adjuvant chemotherapy is established routine therapy for colon cancer (CC) patients with radically resected stage III and 'high-risk' stage II disease. The decision on recommending adjuvant chemotherapy, however, is based on data from older patient cohorts not reflecting improvements...

  17. Robot Aesthetics

    DEFF Research Database (Denmark)

    Jochum, Elizabeth Ann; Putnam, Lance Jonathan

    This paper considers art-based research practice in robotics through a discussion of our course and relevant research projects in autonomous art. The undergraduate course integrates basic concepts of computer science, robotic art, live performance and aesthetic theory. Through practice...... in robotics research (such as aesthetics, culture and perception), we believe robot aesthetics is an important area for research in contemporary aesthetics....

  18. Robotic surgery twice performed in the treatment of hilar cholangiocarcinoma with deep jaundice: delayed right hemihepatectomy following the right-hepatic vascular control.

    Science.gov (United States)

    Zhu, Zhenyu; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Dong, Maosheng; Mu, Peiyuan; Cheng, Di; Che, Honglei; Zhang, Tao; Xu, Xiaoya; Zhou, Ningxin

    2014-10-01

    To explore and find a new method to treat hilar cholangiocarcinoma with deep jaundice assisted by Da Vinci robot. A hilar cholangiocarcinoma patient of type Bismuch-Corlette IIIa was found with deep jaundice (total bilirubin: 635 µmol/L). On the first admission, we performed Da Vinci robotic surgery including drainage of left hepatic duct, dissection of right hepatic vessels (right portal vein and right hepatic artery), and placement of right-hepatic vascular control device. Three weeks later on the second admission when the jaundice disappeared we occluded right-hepatic vascular discontinuously for 6 days and then sustained later. On the third admission after 3 weeks of right-hepatic vascular control, the right hemihepatectomy was performed by Da Vinci robot for the second time. The future liver remnant after the right-hepatic vascular control increased from 35% to 47%. The volume of left lobe increased by 368 mL. When the total bilirubin and liver function were all normal, right hemihepatectomy was performed by Da Vinci robot 10 weeks after the first operation. The removal of atrophic right hepatic lobe with tumor in bile duct was found with no pathologic cancer remaining in the margin. The patient was followed up at our outpatient clinic every 3 months and no tumor recurrence occurs by now (1 y). Under the Da Vinci robotic surgical system, a programmed treatment can be achieved: first, the hepatic vessels were controlled gradually together with biliary drainage, which results in liver's partial atrophy and compensatory hypertrophy in the other part. Then a radical hepatectomy could be achieved. Such programmed hepatectomy provides a new treatment for patients of hilar cholangiocarcinoma with deep jaundice who have the possibility of radical heptolobectomy.

  19. Robots: l'embarras de richesses [:survey of robots available

    International Nuclear Information System (INIS)

    Meieran, H.; Brittain, K.; Sturkey, R.

    1989-01-01

    A survey of robots available for use in the nuclear industry is presented. Two new categories of mobile robots have been introduced since the last survey (April 1987): pipe crawlers and underwater robots. The number of robots available has risen to double what it was two years ago and four times what it was in 1986. (U.K.)

  20. Robots Social Embodiment in Autonomous Mobile Robotics

    Directory of Open Access Journals (Sweden)

    Brian Duffy

    2008-11-01

    Full Text Available This work aims at demonstrating the inherent advantages of embracing a strong notion of social embodiment in designing a real-world robot control architecture with explicit ?intelligent? social behaviour between a collective of robots. It develops the current thinking on embodiment beyond the physical by demonstrating the importance of social embodiment. A social framework develops the fundamental social attributes found when more than one robot co-inhabit a physical space. The social metaphors of identity, character, stereotypes and roles are presented and implemented within a real-world social robot paradigm in order to facilitate the realisation of explicit social goals.

  1. Self-localization for an autonomous mobile robot based on an omni-directional vision system

    Science.gov (United States)

    Chiang, Shu-Yin; Lin, Kuang-Yu; Chia, Tsorng-Lin

    2013-12-01

    In this study, we designed an autonomous mobile robot based on the rules of the Federation of International Robotsoccer Association (FIRA) RoboSot category, integrating the techniques of computer vision, real-time image processing, dynamic target tracking, wireless communication, self-localization, motion control, path planning, and control strategy to achieve the contest goal. The self-localization scheme of the mobile robot is based on the algorithms featured in the images from its omni-directional vision system. In previous works, we used the image colors of the field goals as reference points, combining either dual-circle or trilateration positioning of the reference points to achieve selflocalization of the autonomous mobile robot. However, because the image of the game field is easily affected by ambient light, positioning systems exclusively based on color model algorithms cause errors. To reduce environmental effects and achieve the self-localization of the robot, the proposed algorithm is applied in assessing the corners of field lines by using an omni-directional vision system. Particularly in the mid-size league of the RobotCup soccer competition, selflocalization algorithms based on extracting white lines from the soccer field have become increasingly popular. Moreover, white lines are less influenced by light than are the color model of the goals. Therefore, we propose an algorithm that transforms the omni-directional image into an unwrapped transformed image, enhancing the extraction features. The process is described as follows: First, radical scan-lines were used to process omni-directional images, reducing the computational load and improving system efficiency. The lines were radically arranged around the center of the omni-directional camera image, resulting in a shorter computational time compared with the traditional Cartesian coordinate system. However, the omni-directional image is a distorted image, which makes it difficult to recognize the

  2. Robotic surgery in complicated gynecologic diseases: experience of Tri-Service General Hospital in Taiwan.

    Science.gov (United States)

    Tan, Shun-Jen; Lin, Chi-Kung; Fu, Pei-Te; Liu, Yung-Liang; Sun, Cheng-Chian; Chang, Cheng-Chang; Yu, Mu-Hsien; Lai, Hung-Cheng

    2012-03-01

    Minimally invasive surgery has been the trend in various specialties and continues to evolve as new technology develops. The development of robotic surgery in gynecology remains in its infancy. The present study reports the first descriptive series of robotic surgery in complicated gynecologic diseases in Taiwan. From March 2009 to February 2011, the records of patients undergoing robotic surgery using the da Vinci Surgical System were reviewed for patient demographics, indications, operative time, hospital stay, conversion to laparotomy, and complications. Sixty cases were reviewed in the present study. Forty-nine patients had benign gynecologic diseases, and 11 patients had malignancies. These robot-assisted laparoscopic procedures include nine hysterectomy, 15 subtotal hysterectomy, 13 myomectomy, eight staging operation, two radical hysterectomy, five ovarian cystectomy, one bilateral salpingo-oophorectomy and myomectomy, two resections of deep pelvic endometriosis, one pelvic adhesiolysis, three sacrocolpopexy and one tuboplasty. Thirty-three patients had prior pelvic surgery, and one had a history of pelvic radiotherapy. Adhesiolysis was necessary in 38 patients to complete the whole operation. Robotic myomectomy was easily accomplished in patients with huge uterus or multiple myomas. The suturing of myometrium or cervical stump after ligation of the uterine arteries minimized the blood loss. In addition, it was much easier to dissect severe pelvic adhesions. The dissection of para-aortic lymph nodes can be easily accomplished. All these surgeries were performed smoothly without ureteral, bladder or bowel injury. The present analyses include various complicated gynecologic conditions, which make the estimation of the effectiveness of robotic surgery in each situation individually not appropriate. However, our experiences do show that robotic surgery is feasible and safe for patients with complicated gynecologic diseases. Copyright © 2012. Published by

  3. Radicalization In Pakistan And The Spread Of Radical Islam In Pakistan

    Directory of Open Access Journals (Sweden)

    Bahir ahmad

    2015-08-01

    Full Text Available ABSTRACT It is pertinent to mention that radicalism is not intrinsic to Islam and radical interpretations of the religion or for that matter may occur within any way of life and religion Saikal 2003 and yet the question remains as to why Muslims in certain geographical regions have more radical approaches towards their religion and also that what are the causes of such radicalization. Becoming a radical Muslim is not even a matter of a day nor is it a sudden process. There are several reasons behind making a person radical peaceful angry smiling or tolerant. For knowing the reason behind radicalization or radicals persons one has to understand the causes. Tracing these causes is one of the ways to eliminate such behavior. The first step in the elimination of the radical sentiments in a person is to develop peace in his personality Fair Malhotra amp Shapiro 2010. The chapter which has been addressed here is going to shed light on the roots and symptoms of the radicalism. There will be a brief discussion on how the roots of radicalism can be traced and can be eliminated. The assessment and discussion will be conducted on the parameters of the economy media politics and theology from social cultural point of view. According to the analysis of Ahrari 2000 political factor is one of the major and direct factors which have resulted in causing of the radicalism. These factors however intertwine with one another. Radical actions cannot take place only because of the political factors.

  4. Robotic intelligence kernel

    Science.gov (United States)

    Bruemmer, David J [Idaho Falls, ID

    2009-11-17

    A robot platform includes perceptors, locomotors, and a system controller. The system controller executes a robot intelligence kernel (RIK) that includes a multi-level architecture and a dynamic autonomy structure. The multi-level architecture includes a robot behavior level for defining robot behaviors, that incorporate robot attributes and a cognitive level for defining conduct modules that blend an adaptive interaction between predefined decision functions and the robot behaviors. The dynamic autonomy structure is configured for modifying a transaction capacity between an operator intervention and a robot initiative and may include multiple levels with at least a teleoperation mode configured to maximize the operator intervention and minimize the robot initiative and an autonomous mode configured to minimize the operator intervention and maximize the robot initiative. Within the RIK at least the cognitive level includes the dynamic autonomy structure.

  5. Low Pressure Robot-assisted Radical Prostatectomy With the AirSeal System at OLV Hospital: Results From a Prospective Study.

    Science.gov (United States)

    La Falce, Sabrina; Novara, Giacomo; Gandaglia, Giorgio; Umari, Paolo; De Naeyer, Geert; D'Hondt, Frederiek; Beresian, Jean; Carette, Rik; Penicka, Martin; Mo, Yujiing; Vandenbroucke, Geert; Mottrie, Alexandre

    2017-12-01

    Limited studies examined effects of pneumoperiotneum during robot-assisted radical prostatectomy (RARP) and with AirSeal. The aim of this study was to assess the effect on hemodynamics of a lower pressure pneumoperitoneum (8 mmHg) with AirSeal, during RARP in steep Trendelenburg 45° (ST). This is an institutional review board-approved, prospective, interventional, single-center study including patients treated with RARP at OLV Hospital by one extremely experienced surgeon (July 2015-February 2016). Intraoperative monitoring included: arterial pressure, central venous pressure, cardiac output, heart rate, stroke volume, systemic vascular resistance, intrathoracic pressure, airways pressures, left ventricular end-diastolic and end-systolic areas/volumes and ejection fraction, by transesophageal echocardiography, an esophageal catheter, and FloTrac/Vigileo system. Measurements were performed after induction of anesthesia with patient in horizontal (T0), 5 minutes after 8 mmHg pneumoperitoneum (TP), 5 minutes after ST (TT1) and every 30 minutes thereafter until the end of surgery (TH). Parameters modification at the prespecified times was assessed by Wilcoxon and Friedman tests, as appropriate. All analyses were performed by SPSS v. 23.0. A total of 53 consecutive patients were enrolled. The mean patients age was 62.6 ± 6.9 years. Comorbidity was relatively limited (51% with Charlson Comorbidity Index as low as 0). Despite the ST, working always at 8 mmHg with AirSeal, only central venous pressure and mean airways pressure showed a statistically significant variation during the operative time. Although other significant hemodynamic/respiratory changes were observed adding pneumoperitoneum and then ST, all variables remained always within limits safely manageable by anesthesiologists. The combination of ST, lower pressure pneumoperitoneum and extreme surgeon's experience enables to safely perform RARP. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. An Intelligent Robot Programing

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Yong

    2012-01-15

    This book introduces an intelligent robot programing with background of the begging, introduction of VPL, and SPL, building of environment for robot platform, starting of robot programing, design of simulation environment, robot autonomy drive control programing, simulation graphic. Such as SPL graphic programing graphical image and graphical shapes, and graphical method application, application of procedure for robot control, robot multiprogramming, robot bumper sensor programing, robot LRF sencor programing and robot color sensor programing.

  7. An Intelligent Robot Programing

    International Nuclear Information System (INIS)

    Hong, Seong Yong

    2012-01-01

    This book introduces an intelligent robot programing with background of the begging, introduction of VPL, and SPL, building of environment for robot platform, starting of robot programing, design of simulation environment, robot autonomy drive control programing, simulation graphic. Such as SPL graphic programing graphical image and graphical shapes, and graphical method application, application of procedure for robot control, robot multiprogramming, robot bumper sensor programing, robot LRF sencor programing and robot color sensor programing.

  8. Neuro-robotics from brain machine interfaces to rehabilitation robotics

    CERN Document Server

    Artemiadis

    2014-01-01

    Neuro-robotics is one of the most multidisciplinary fields of the last decades, fusing information and knowledge from neuroscience, engineering and computer science. This book focuses on the results from the strategic alliance between Neuroscience and Robotics that help the scientific community to better understand the brain as well as design robotic devices and algorithms for interfacing humans and robots. The first part of the book introduces the idea of neuro-robotics, by presenting state-of-the-art bio-inspired devices. The second part of the book focuses on human-machine interfaces for pe

  9. Assessing the Impact of Surgeon Experience on Urinary Continence Recovery After Robot-Assisted Radical Prostatectomy: Results of Four High-Volume Surgeons.

    Science.gov (United States)

    Fossati, Nicola; Di Trapani, Ettore; Gandaglia, Giorgio; Dell'Oglio, Paolo; Umari, Paolo; Buffi, Nicolò Maria; Guazzoni, Giorgio; Mottrie, Alexander; Gaboardi, Franco; Montorsi, Francesco; Briganti, Alberto; Suardi, Nazareno

    2017-09-01

    To test the impact of surgeon experience on urinary continence (UC) recovery after robot-assisted radical prostatectomy (RARP). The study included 1477 consecutive patients treated with RARP by four surgeons between 2006 and 2014. UC recovery was defined as being completely dry over a 24-hour period at follow-up. Surgeon experience was coded as the total number of RARP performed by the surgeon before the patient's operation. Multivariable analysis tested the association between surgeon experience and UC recovery. Covariates consisted of patient age, Charlson comorbidity index, preoperative International Index of Erectile Function-Erectile Function domain (IIEF-EF), nerve-sparing surgery (none vs unilateral vs bilateral), and preoperative risk groups (low- vs intermediate- vs high risk). The number of cases performed by each surgeon was 541, 413, 411, and 112, respectively. Median follow-up was 24 months (inter-quartile range: 18, 40). The UC recovery rate at 1 year after surgery was 82%. At multivariable analyses, surgeon experience represented an independent predictor of UC recovery (hazard ratio: 1.02, p < 0.001). The surgical learning curve was similar among surgeons, moving linearly from ∼60% of UC rate at the initial cases to almost 90% after more than 400 procedures. In patients undergoing RARP, surgeon experience is a significant predictor of UC recovery. The surgical learning curve of UC recovery does not reach a plateau even after more than 100 cases, suggesting a continuous improvement of the surgical technique. These findings deserve attention for patient counseling and future comparative studies evaluating functional outcomes after RARP.

  10. Cloud Robotics Model

    OpenAIRE

    Mester, Gyula

    2015-01-01

    Cloud Robotics was born from the merger of service robotics and cloud technologies. It allows robots to benefit from the powerful computational, storage, and communications resources of modern data centres. Cloud robotics allows robots to take advantage of the rapid increase in data transfer rates to offload tasks without hard real time requirements. Cloud Robotics has rapidly gained momentum with initiatives by companies such as Google, Willow Garage and Gostai as well as more than a dozen a...

  11. Space Robotics Challenge

    Data.gov (United States)

    National Aeronautics and Space Administration — The Space Robotics Challenge seeks to infuse robot autonomy from the best and brightest research groups in the robotics community into NASA robots for future...

  12. Are Sex Robots as Bad as Killing Robots

    OpenAIRE

    Richardson, Kathleen

    2016-01-01

    In 2015 the Campaign Against Sex Robots was launched to draw attention to the technological production of new kinds of objects: sex robots of women and children. The campaign was launched shortly after the Future of Life Institute published an online petition: “Autonomous Weapons: An Open Letter From AI and Robotics Researchers” which was signed by leading luminaries in the field of AI and Robotics. In response to the Campaign, an academic at Oxford University opened an ethics thread “Are sex...

  13. Multi-robot control interface

    Science.gov (United States)

    Bruemmer, David J [Idaho Falls, ID; Walton, Miles C [Idaho Falls, ID

    2011-12-06

    Methods and systems for controlling a plurality of robots through a single user interface include at least one robot display window for each of the plurality of robots with the at least one robot display window illustrating one or more conditions of a respective one of the plurality of robots. The user interface further includes at least one robot control window for each of the plurality of robots with the at least one robot control window configured to receive one or more commands for sending to the respective one of the plurality of robots. The user interface further includes a multi-robot common window comprised of information received from each of the plurality of robots.

  14. Ambulatory movements, team dynamics and interactions during robot-assisted surgery.

    Science.gov (United States)

    Ahmad, Nabeeha; Hussein, Ahmed A; Cavuoto, Lora; Sharif, Mohamed; Allers, Jenna C; Hinata, Nobuyuki; Ahmad, Basel; Kozlowski, Justen D; Hashmi, Zishan; Bisantz, Ann; Guru, Khurshid A

    2016-07-01

    To analyse ambulatory movements and team dynamics during robot-assisted surgery (RAS), and to investigate whether congestion of the physical space associated with robotic technology led to workflow challenges or predisposed to errors and adverse events. With institutional review board approval, we retrospectively reviewed 10 recorded robot-assisted radical prostatectomies in a single operating room (OR). The OR was divided into eight zones, and all movements were tracked and described in terms of start and end zones, duration, personnel and purpose. Movements were further classified into avoidable (can be eliminated/improved) and unavoidable (necessary for completion of the procedure). The mean operating time was 166 min, of which ambulation constituted 27 min (16%). A total of 2 896 ambulatory movements were identified (mean: 290 ambulatory movements/procedure). Most of the movements were procedure-related (31%), and were performed by the circulating nurse. We identified 11 main pathways in the OR; the heaviest traffic was between the circulating nurse zone, transit zone and supply-1 zone. A total of 50% of ambulatory movements were found to be avoidable. More than half of the movements during RAS can be eliminated with an improved OR setting. More studies are needed to design an evidence-based OR layout that enhances access, workflow and patient safety. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  15. Robotics

    Energy Technology Data Exchange (ETDEWEB)

    Lorino, P; Altwegg, J M

    1985-05-01

    This article, which is aimed at the general reader, examines latest developments in, and the role of, modern robotics. The 7 main sections are sub-divided into 27 papers presented by 30 authors. The sections are as follows: 1) The role of robotics, 2) Robotics in the business world and what it can offer, 3) Study and development, 4) Utilisation, 5) Wages, 6) Conditions for success, and 7) Technological dynamics.

  16. FPGA for Robotic Applications: from Android/Humanoid Robots to Artificial Men

    Directory of Open Access Journals (Sweden)

    Tole Sutikno

    2011-12-01

    Full Text Available Researches on home robots have been increasing enormously. There has always existed a continuous research effort on problems of anthropomorphic robots which is now called humanoid robots. Currently, robotics has evolved to the point that different branches have reached a remarkable level of maturity, that neural network and fuzzy logic are the main artificial intelligence as intelligent control on the robotics. Despite all this progress, while aiming at accomplishing work-tasks originally charged only to humans, robotic science has perhaps quite naturally turned into the attempt to create artificial men. It is true that artificial men or android humanoid robots open certainly very broad prospects. This “robot” may be viewed as a personal helper, and it will be called a home-robot, or personal robot. This is main reason why the two special sections are issued in the TELKOMNIKA sequentially.

  17. A traffic priority language for collision-free navigation of autonomous mobile robots in dynamic environments.

    Science.gov (United States)

    Bourbakis, N G

    1997-01-01

    This paper presents a generic traffic priority language, called KYKLOFORTA, used by autonomous robots for collision-free navigation in a dynamic unknown or known navigation space. In a previous work by X. Grossmman (1988), a set of traffic control rules was developed for the navigation of the robots on the lines of a two-dimensional (2-D) grid and a control center coordinated and synchronized their movements. In this work, the robots are considered autonomous: they are moving anywhere and in any direction inside the free space, and there is no need of a central control to coordinate and synchronize them. The requirements for each robot are i) visual perception, ii) range sensors, and iii) the ability of each robot to detect other moving objects in the same free navigation space, define the other objects perceived size, their velocity and their directions. Based on these assumptions, a traffic priority language is needed for each robot, making it able to decide during the navigation and avoid possible collision with other moving objects. The traffic priority language proposed here is based on a set of primitive traffic priority alphabet and rules which compose pattern of corridors for the application of the traffic priority rules.

  18. Teaching Joint-Level Robot Programming with a New Robotics Software Tool

    Directory of Open Access Journals (Sweden)

    Fernando Gonzalez

    2017-12-01

    Full Text Available With the rising popularity of robotics in our modern world there is an increase in the number of engineering programs that offer the basic Introduction to Robotics course. This common introductory robotics course generally covers the fundamental theory of robotics including robot kinematics, dynamics, differential movements, trajectory planning and basic computer vision algorithms commonly used in the field of robotics. Joint programming, the task of writing a program that directly controls the robot’s joint motors, is an activity that involves robot kinematics, dynamics, and trajectory planning. In this paper, we introduce a new educational robotics tool developed for teaching joint programming. The tool allows the student to write a program in a modified C language that controls the movement of the arm by controlling the velocity of each joint motor. This is a very important activity in the robotics course and leads the student to gain knowledge of how to build a robotic arm controller. Sample assignments are presented for different levels of difficulty.

  19. Robotics-based synthesis of human motion

    KAUST Repository

    Khatib, O.; Demircan, E.; De Sapio, V.; Sentis, L.; Besier, T.; Delp, S.

    2009-01-01

    The synthesis of human motion is a complex procedure that involves accurate reconstruction of movement sequences, modeling of musculoskeletal kinematics, dynamics and actuation, and characterization of reliable performance criteria. Many of these processes have much in common with the problems found in robotics research. Task-based methods used in robotics may be leveraged to provide novel musculoskeletal modeling methods and physiologically accurate performance predictions. In this paper, we present (i) a new method for the real-time reconstruction of human motion trajectories using direct marker tracking, (ii) a task-driven muscular effort minimization criterion and (iii) new human performance metrics for dynamic characterization of athletic skills. Dynamic motion reconstruction is achieved through the control of a simulated human model to follow the captured marker trajectories in real-time. The operational space control and real-time simulation provide human dynamics at any configuration of the performance. A new criteria of muscular effort minimization has been introduced to analyze human static postures. Extensive motion capture experiments were conducted to validate the new minimization criterion. Finally, new human performance metrics were introduced to study in details an athletic skill. These metrics include the effort expenditure and the feasible set of operational space accelerations during the performance of the skill. The dynamic characterization takes into account skeletal kinematics as well as muscle routing kinematics and force generating capacities. The developments draw upon an advanced musculoskeletal modeling platform and a task-oriented framework for the effective integration of biomechanics and robotics methods.

  20. Robotics-based synthesis of human motion

    KAUST Repository

    Khatib, O.

    2009-05-01

    The synthesis of human motion is a complex procedure that involves accurate reconstruction of movement sequences, modeling of musculoskeletal kinematics, dynamics and actuation, and characterization of reliable performance criteria. Many of these processes have much in common with the problems found in robotics research. Task-based methods used in robotics may be leveraged to provide novel musculoskeletal modeling methods and physiologically accurate performance predictions. In this paper, we present (i) a new method for the real-time reconstruction of human motion trajectories using direct marker tracking, (ii) a task-driven muscular effort minimization criterion and (iii) new human performance metrics for dynamic characterization of athletic skills. Dynamic motion reconstruction is achieved through the control of a simulated human model to follow the captured marker trajectories in real-time. The operational space control and real-time simulation provide human dynamics at any configuration of the performance. A new criteria of muscular effort minimization has been introduced to analyze human static postures. Extensive motion capture experiments were conducted to validate the new minimization criterion. Finally, new human performance metrics were introduced to study in details an athletic skill. These metrics include the effort expenditure and the feasible set of operational space accelerations during the performance of the skill. The dynamic characterization takes into account skeletal kinematics as well as muscle routing kinematics and force generating capacities. The developments draw upon an advanced musculoskeletal modeling platform and a task-oriented framework for the effective integration of biomechanics and robotics methods.

  1. Value-based assessment of robotic pancreas and liver surgery.

    Science.gov (United States)

    Patti, James C; Ore, Ana Sofia; Barrows, Courtney; Velanovich, Vic; Moser, A James

    2017-08-01

    Current healthcare economic evaluations are based only on the perspective of a single stakeholder to the healthcare delivery process. A true value-based decision incorporates all of the outcomes that could be impacted by a single episode of surgical care. We define the value proposition for robotic surgery using a stakeholder model incorporating the interests of all groups participating in the provision of healthcare services: patients, surgeons, hospitals and payers. One of the developing and expanding fields that could benefit the most from a complete value-based analysis is robotic hepatopancreaticobiliary (HPB) surgery. While initial robot purchasing costs are high, the benefits over laparoscopic surgery are considerable. Performing a literature search we found a total of 18 economic evaluations for robotic HPB surgery. We found a lack of evaluations that were carried out from a perspective that incorporates all of the impacts of a single episode of surgical care and that included a comprehensive hospital cost assessment. For distal pancreatectomies, the two most thorough examinations came to conflicting results regarding total cost savings compared to laparoscopic approaches. The most thorough pancreaticoduodenectomy evaluation found non-significant savings for total hospital costs. Robotic hepatectomies showed no cost savings over laparoscopic and only modest savings over open techniques. Lastly, robotic cholecystectomies were found to be more expensive than the gold-standard laparoscopic approach. Existing cost accounting data associated with robotic HPB surgery is incomplete and unlikely to reflect the state of this field in the future. Current data combines the learning curves for new surgical procedures being undertaken by HPB surgeons with costs derived from a market dominated by a single supplier of robotic instruments. As a result, the value proposition for stakeholders in this process cannot be defined. In order to solve this problem, future studies

  2. Magnetic Resonance Studies of Proton Loss from Carotenoid Radical Cations

    Energy Technology Data Exchange (ETDEWEB)

    Kispert, Lowell D [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Focsan, A Ligia [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Konovalova, Tatyana A [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lawrence, Jesse [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bowman, Michael K [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dixon, David A [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Molnar, Peter [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deli, Jozsef [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2007-06-11

    Carotenoids, intrinsic components of reaction centers and pigment-protein complexes in photosynthetic membranes, play a photoprotective role and serve as a secondary electron donor. Before optimum use of carotenoids can be made in artificial photosynthetic systems, their robust nature in living materials requires extensive characterization of their electron transfer, radical trapping ability, stability, structure in and on various hosts, and photochemical behavior. Pulsed ENDOR and 2D-HYSCORE studies combined with DFT calculations reveal that photo-oxidation of natural zeaxanthin (I) and violaxanthin (II) on silica-alumina produces not only the carotenoid radical cations (Car•+) but also neutral radicals (#Car•) by proton loss from the methyl groups at positions 5 or 5', and possibly 9 or 9' and 13 or 13'. Notably, the proton loss favored in I at the 5 position by DFT calculations, is unfavorable in II due to the epoxide at the 5, 6 position. DFT calculations predict the isotropic methyl proton couplings of 8-10 MHz for Car•+ which agree with the ENDOR for carotenoid α-conjugated radical cations. Large α-proton hyperfine coupling constants (>10 MHz) determined from HYSCORE are assigned from the DFT calculations to neutral carotenoid radicals. Proton loss upon photolysis was also examined as a function of carotenoid polarity [Lycopene (III) versus 8'-apo-β-caroten-8'-al (IV)]; hydrogen bonding [Lutein (V) versus III]; host [silica-alumina versus MCM-41 molecular sieve]; and substituted metal in MCM-41. Loss of H+ from the 5(5'), 9(9') or 13(13') methyl positions has importance in photoprotection. Photoprotection involves nonphotochemical quenching (NPQ) in which 1Ch1* decays via energy transfer to the carotenoid which returns to the ground state by thermal dissipation; or via electron transfer to form a charge transfer state (I •+…Chl•-), lower in energy than 1Chl*. Formation of I •+ results in bond

  3. The role of robotic partial cystectomy in a patient with metastatic primary adenocarcinoma of the bladder

    Directory of Open Access Journals (Sweden)

    Katherine James

    2015-03-01

    Full Text Available Treatment of urachal adenocarcinoma (UA of the urinary bladder has typically been with radical cystectomy (RC but more conservative approaches are gaining popularity. Here we present the case of a female patient with metastatic primary bladder UA who was treated with robotic partial cystectomy (RPC and adjuvant chemotherapy; she is alive with no evidence of disease recurrence or metastatic disease at 5 years. This case provides some of the longest follow-up after RPC to date thereby demonstrating that RPC is a safe and oncologically viable treatment for selected patients even several years after definitive treatment. Patients undergoing RPC benefit from the reduced morbidity associated with this less radical treatment whilst enjoying similarly successful oncological outcomes to RC.   

  4. Correction of Visual Perception Based on Neuro-Fuzzy Learning for the Humanoid Robot TEO

    Directory of Open Access Journals (Sweden)

    Juan Hernandez-Vicen

    2018-03-01

    Full Text Available New applications related to robotic manipulation or transportation tasks, with or without physical grasping, are continuously being developed. To perform these activities, the robot takes advantage of different kinds of perceptions. One of the key perceptions in robotics is vision. However, some problems related to image processing makes the application of visual information within robot control algorithms difficult. Camera-based systems have inherent errors that affect the quality and reliability of the information obtained. The need of correcting image distortion slows down image parameter computing, which decreases performance of control algorithms. In this paper, a new approach to correcting several sources of visual distortions on images in only one computing step is proposed. The goal of this system/algorithm is the computation of the tilt angle of an object transported by a robot, minimizing image inherent errors and increasing computing speed. After capturing the image, the computer system extracts the angle using a Fuzzy filter that corrects at the same time all possible distortions, obtaining the real angle in only one processing step. This filter has been developed by the means of Neuro-Fuzzy learning techniques, using datasets with information obtained from real experiments. In this way, the computing time has been decreased and the performance of the application has been improved. The resulting algorithm has been tried out experimentally in robot transportation tasks in the humanoid robot TEO (Task Environment Operator from the University Carlos III of Madrid.

  5. Timing of Multimodal Robot Behaviors during Human-Robot Collaboration

    DEFF Research Database (Denmark)

    Jensen, Lars Christian; Fischer, Kerstin; Suvei, Stefan-Daniel

    2017-01-01

    In this paper, we address issues of timing between robot behaviors in multimodal human-robot interaction. In particular, we study what effects sequential order and simultaneity of robot arm and body movement and verbal behavior have on the fluency of interactions. In a study with the Care-O-bot, ...... output plays a special role because participants carry their expectations from human verbal interaction into the interactions with robots....

  6. Robotics Potential Fields

    Directory of Open Access Journals (Sweden)

    Jordi Lucero

    2009-01-01

    Full Text Available This problem was to calculate the path a robot would take to navigate an obstacle field and get to its goal. Three obstacles were given as negative potential fields which the robot avoided, and a goal was given a positive potential field that attracted the robot. The robot decided each step based on its distance, angle, and influence from every object. After each step, the robot recalculated and determined its next step until it reached its goal. The robot's calculations and steps were simulated with Microsoft Excel.

  7. Systematic Review of Studies Reporting Positive Surgical Margins After Bladder Neck Sparing Radical Prostatectomy.

    Science.gov (United States)

    Bellangino, Mariangela; Verrill, Clare; Leslie, Tom; Bell, Richard W; Hamdy, Freddie C; Lamb, Alastair D

    2017-11-07

    Bladder neck preservation (BNP) during radical prostatectomy (RP) has been proposed as a method to improve early recovery of urinary continence after radical prostatectomy. However, there is concern over a possible increase in the risk of positive surgical margins and prostate cancer recurrence rate. A recent systematic review and meta-analysis reported improved early recovery and overall long-term urinary continence without compromising oncologic control. The aim of our study was to perform a critical review of the literature to assess the impact on bladder neck and base margins after bladder neck sparing radical prostatectomy. We carried out a systematic review of the literature using Pubmed, Scopus and Cochrane library databases in May 2017 using medical subject headings and free-text protocol according to PRISMA guidelines. We used the following search terms: bladder neck preservation, prostate cancer, radical prostatectomy and surgical margins. Studies focusing on positive surgical margins (PSM) in bladder neck sparing RP pertinent to the objective of this review were included. Overall, we found 15 relevant studies reporting overall and site-specific positive surgical margins rate after bladder neck sparing radical prostatectomy. This included two RCTs, seven prospective comparative studies, two retrospective comparative studies and four case series. All studies were published between 1993 and 2015 with sample sizes ranging between 50 and 1067. Surgical approaches included open, laparoscopic and robot-assisted radical prostatectomy. The overall and base-specific PSM rates ranged between 7-36% and 0-16.3%, respectively. Mean base PSM was 4.9% in those patients where bladder neck sparing was performed, but only 1.85% in those without sparing. Bladder neck preservation during radical prostatectomy may increase base-positive margins. Further studies are needed to better investigate the impact of this technique on oncological outcomes. A future paradigm could

  8. Healthcare Robotics

    OpenAIRE

    Riek, Laurel D.

    2017-01-01

    Robots have the potential to be a game changer in healthcare: improving health and well-being, filling care gaps, supporting care givers, and aiding health care workers. However, before robots are able to be widely deployed, it is crucial that both the research and industrial communities work together to establish a strong evidence-base for healthcare robotics, and surmount likely adoption barriers. This article presents a broad contextualization of robots in healthcare by identifying key sta...

  9. RIPE [robot independent programming environment]: A robot independent programming environment

    International Nuclear Information System (INIS)

    Miller, D.J.; Lennox, R.C.

    1990-01-01

    Remote manual operations in radiation environments are typically performed very slowly. Sensor-based computer-controlled robots hold great promise for increasing the speed and safety of remote operations; however, the programming of robotic systems has proven to be expensive and difficult. Generalized approaches to robot programming that reuse available software modules and employ programming languages which are independent of the specific robotic and sensory devices being used are needed to speed software development and increase overall system reliability. This paper discusses the robot independent programming environment (RIPE) developed at Sandia National Laboratories (SNL). The RIPE is an object-oriented approach to robot system architectures; it is a software environment that facilitates rapid design and implementation of complex robot systems for diverse applications. An architecture based on hierarchies of distributed multiprocessors provides the computing platform for a layered programming structure that models applications using software objects. These objects are designed to support model-based automated programming of robotic and machining devices, real-time sensor-based control, error handling, and robust communication

  10. Evolutionary Developmental Robotics: Improving Morphology and Control of Physical Robots.

    Science.gov (United States)

    Vujovic, Vuk; Rosendo, Andre; Brodbeck, Luzius; Iida, Fumiya

    2017-01-01

    Evolutionary algorithms have previously been applied to the design of morphology and control of robots. The design space for such tasks can be very complex, which can prevent evolution from efficiently discovering fit solutions. In this article we introduce an evolutionary-developmental (evo-devo) experiment with real-world robots. It allows robots to grow their leg size to simulate ontogenetic morphological changes, and this is the first time that such an experiment has been performed in the physical world. To test diverse robot morphologies, robot legs of variable shapes were generated during the evolutionary process and autonomously built using additive fabrication. We present two cases with evo-devo experiments and one with evolution, and we hypothesize that the addition of a developmental stage can be used within robotics to improve performance. Moreover, our results show that a nonlinear system-environment interaction exists, which explains the nontrivial locomotion patterns observed. In the future, robots will be present in our daily lives, and this work introduces for the first time physical robots that evolve and grow while interacting with the environment.

  11. Free radical inactivation of trypsin

    International Nuclear Information System (INIS)

    Cudina, Ivana; Jovanovic, S.V.

    1988-01-01

    Reactivities of free radical oxidants, radical OH, Br2-anion radical and Cl 3 COO radical and a reductant, CO2-anion radical, with trypsin and reactive protein components were determined by pulse radiolysis of aqueous solutions at pH 7, 20 0 C. Highly reactive free radicals, radical OH, Br2-anion radical and CO2-anion radical, react with trypsin at diffusion controlled rates. Moderately reactive trichloroperoxy radical, k(Cl 3 COO radical + trypsin) preferentially oxidizes histidine residues. The efficiency of inactivation of trypsin by free radicals is inversely proportional to their reactivity. The yields of inactivation of trypsin by radical OH, Br2-anion radical and CO2-anion radical are low, G(inactivation) = 0.6-0.8, which corresponds to ∼ 10% of the initially produced radicals. In contrast, Cl 3 COO radical inactivates trypsin with ∼ 50% efficiency, i.e. G(inactivation) = 3.2. (author)

  12. Recent advances in robotics

    International Nuclear Information System (INIS)

    Beni, G.; Hackwood, S.

    1984-01-01

    Featuring 10 contributions, this volume offers a state-of-the-art report on robotic science and technology. It covers robots in modern industry, robotic control to help the disabled, kinematics and dynamics, six-legged walking robots, a vector analysis of robot manipulators, tactile sensing in robots, and more

  13. Put Your Robot In, Put Your Robot Out: Sequencing through Programming Robots in Early Childhood

    Science.gov (United States)

    Kazakoff, Elizabeth R.; Bers, Marina Umaschi

    2014-01-01

    This article examines the impact of programming robots on sequencing ability in early childhood. Thirty-four children (ages 4.5-6.5 years) participated in computer programming activities with a developmentally appropriate tool, CHERP, specifically designed to program a robot's behaviors. The children learned to build and program robots over three…

  14. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  15. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  16. Human Robot Interaction for Hybrid Collision Avoidance System for Indoor Mobile Robots

    Directory of Open Access Journals (Sweden)

    Mazen Ghandour

    2017-06-01

    Full Text Available In this paper, a novel approach for collision avoidance for indoor mobile robots based on human-robot interaction is realized. The main contribution of this work is a new technique for collision avoidance by engaging the human and the robot in generating new collision-free paths. In mobile robotics, collision avoidance is critical for the success of the robots in implementing their tasks, especially when the robots navigate in crowded and dynamic environments, which include humans. Traditional collision avoidance methods deal with the human as a dynamic obstacle, without taking into consideration that the human will also try to avoid the robot, and this causes the people and the robot to get confused, especially in crowded social places such as restaurants, hospitals, and laboratories. To avoid such scenarios, a reactive-supervised collision avoidance system for mobile robots based on human-robot interaction is implemented. In this method, both the robot and the human will collaborate in generating the collision avoidance via interaction. The person will notify the robot about the avoidance direction via interaction, and the robot will search for the optimal collision-free path on the selected direction. In case that no people interacted with the robot, it will select the navigation path autonomously and select the path that is closest to the goal location. The humans will interact with the robot using gesture recognition and Kinect sensor. To build the gesture recognition system, two models were used to classify these gestures, the first model is Back-Propagation Neural Network (BPNN, and the second model is Support Vector Machine (SVM. Furthermore, a novel collision avoidance system for avoiding the obstacles is implemented and integrated with the HRI system. The system is tested on H20 robot from DrRobot Company (Canada and a set of experiments were implemented to report the performance of the system in interacting with the human and avoiding

  17. Robots and lattice automata

    CERN Document Server

    Adamatzky, Andrew

    2015-01-01

    The book gives a comprehensive overview of the state-of-the-art research and engineering in theory and application of Lattice Automata in design and control of autonomous Robots. Automata and robots share the same notional meaning. Automata (originated from the latinization of the Greek word “αυτόματον”) as self-operating autonomous machines invented from ancient years can be easily considered the first steps of robotic-like efforts. Automata are mathematical models of Robots and also they are integral parts of robotic control systems. A Lattice Automaton is a regular array or a collective of finite state machines, or automata. The Automata update their states by the same rules depending on states of their immediate neighbours. In the context of this book, Lattice Automata are used in developing modular reconfigurable robotic systems, path planning and map exploration for robots, as robot controllers, synchronisation of robot collectives, robot vision, parallel robotic actuators. All chapters are...

  18. Robot vision

    International Nuclear Information System (INIS)

    Hall, E.L.

    1984-01-01

    Almost all industrial robots use internal sensors such as shaft encoders which measure rotary position, or tachometers which measure velocity, to control their motions. Most controllers also provide interface capabilities so that signals from conveyors, machine tools, and the robot itself may be used to accomplish a task. However, advanced external sensors, such as visual sensors, can provide a much greater degree of adaptability for robot control as well as add automatic inspection capabilities to the industrial robot. Visual and other sensors are now being used in fundamental operations such as material processing with immediate inspection, material handling with adaption, arc welding, and complex assembly tasks. A new industry of robot vision has emerged. The application of these systems is an area of great potential

  19. Multi-Locomotion Robotic Systems New Concepts of Bio-inspired Robotics

    CERN Document Server

    Fukuda, Toshio; Sekiyama, Kosuke; Aoyama, Tadayoshi

    2012-01-01

    Nowadays, multiple attention have been paid on a robot working in the human living environment, such as in the field of medical, welfare, entertainment and so on. Various types of researches are being conducted actively in a variety of fields such as artificial intelligence, cognitive engineering, sensor- technology, interfaces and motion control. In the future, it is expected to realize super high functional human-like robot by integrating technologies in various fields including these types of researches. The book represents new developments and advances in the field of bio-inspired robotics research introducing the state of the art, the idea of multi-locomotion robotic system to implement the diversity of animal motion. It covers theoretical and computational aspects of Passive Dynamic Autonomous Control (PDAC), robot motion control, multi legged walking and climbing as well as brachiation focusing concrete robot systems, components and applications. In addition, gorilla type robot systems are described as...

  20. Robot Wars: US Empire and geopolitics in the robotic age

    Science.gov (United States)

    Shaw, Ian GR

    2017-01-01

    How will the robot age transform warfare? What geopolitical futures are being imagined by the US military? This article constructs a robotic futurology to examine these crucial questions. Its central concern is how robots – driven by leaps in artificial intelligence and swarming – are rewiring the spaces and logics of US empire, warfare, and geopolitics. The article begins by building a more-than-human geopolitics to de-center the role of humans in conflict and foreground a worldly understanding of robots. The article then analyzes the idea of US empire, before speculating upon how and why robots are materializing new forms of proxy war. A three-part examination of the shifting spaces of US empire then follows: (1) Swarm Wars explores the implications of miniaturized drone swarming; (2) Roboworld investigates how robots are changing US military basing strategy and producing new topological spaces of violence; and (3) The Autogenic Battle-Site reveals how autonomous robots will produce emergent, technologically event-ful sites of security and violence – revolutionizing the battlespace. The conclusion reflects on the rise of a robotic US empire and its consequences for democracy. PMID:29081605

  1. The evolution of the application of mobile robotics to nuclear facility operations and maintenance

    International Nuclear Information System (INIS)

    Carlton, R.E.; Bartholet, S.J.

    1987-01-01

    Application of the concept of mobile robotics to the operation and maintenance of nuclear facilities has evolved over the last four years due, in part, to the efforts of Odetics in the creation of the teleoperated legged transporter. The first step in this evolutionary process was the demonstration of the legged transporter technology, which was accomplished with the design, fabrication and testing of the Odex I functionoid. A second generation ODEX, delivered to the Robotics Technology Group at Savannah River Laboratories, represents the experimental phase of the process. This machine consists of a basic ODEX I transporter body with a unique manipulator arm mounted on a service turret. Currently, the prototype phase of the mobile robotic development effort is underway with the design of the ODEX III which includes enhanced mobility and dexterity, increased intelligence and greater strength in the manipulator arm and transporter

  2. Robotic vision system for random bin picking with dual-arm robots

    Directory of Open Access Journals (Sweden)

    Kang Sangseung

    2016-01-01

    Full Text Available Random bin picking is one of the most challenging industrial robotics applications available. It constitutes a complicated interaction between the vision system, robot, and control system. For a packaging operation requiring a pick-and-place task, the robot system utilized should be able to perform certain functions for recognizing the applicable target object from randomized objects in a bin. In this paper, we introduce a robotic vision system for bin picking using industrial dual-arm robots. The proposed system recognizes the best object from randomized target candidates based on stereo vision, and estimates the position and orientation of the object. It then sends the result to the robot control system. The system was developed for use in the packaging process of cell phone accessories using dual-arm robots.

  3. Modular Robotic Wearable

    DEFF Research Database (Denmark)

    Lund, Henrik Hautop; Pagliarini, Luigi

    2009-01-01

    In this concept paper we trace the contours and define a new approach to robotic systems, composed of interactive robotic modules which are somehow worn on the body. We label such a field as Modular Robotic Wearable (MRW). We describe how, by using modular robotics for creating wearable....... Finally, by focusing on the intersection of the combination modular robotic systems, wearability, and bodymind we attempt to explore the theoretical characteristics of such approach and exploit the possible playware application fields....

  4. Incidence of positive surgical margins after robotic assisted radical prostatectomy: Does the surgeon's experience have an influence on all pathological stages?

    Science.gov (United States)

    Villamil, A W; Costabel, J I; Billordo Peres, N; Martínez, P F; Giudice, C R; Damia, O H

    2014-03-01

    The aim of this study is to analyze the clinical and surgical features of patients who underwent robotic-assisted radical prostatectomy (RARP) at our institution, and the impact of the surgeon's experience in the oncological results related to pathological stage. An analysis of 300 RARP consecutively performed by the same urologist was conducted. Patients were divided into 3 groups of 100 patients in chronological order, according to surgery date. All patients had organ-confined clinical stage. Variables which could impact in positive margins rates were analyzed. Finally, positive surgical margins (PSM) in regard to pathological stage and surgeon's experience were compared and analyzed. No significant differences were found in variables which could impact in PSM rates. The overall PSM rate was 21%, with 28% in the first group, 20% in the second, and 16% in the third (P = .108). Significant lineal decreasing tendency was observed (P = .024). In pT2 patients, the overall PSM rate was 16.6%, with 27%, 13.8%, and 7.3% in each group respectively (P = .009). A significant difference was found between group 1 and group 3 (P = .004). In pT3 patients, the surgeon's experience was not significantly associated with margin reductions with an overall PSM rate of 27.7% (28.2%, 28.6%, and 26.7% in each group respectively). Clinical and surgical features in our patients did not vary over time. We found a significant reduction of PSM related to surgeon's experience in pT2 patients. Contrariwise, the margin status remained stable despite increasing experience in pT3 patients. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  5. Marine Robot Autonomy

    CERN Document Server

    2013-01-01

    Autonomy for Marine Robots provides a timely and insightful overview of intelligent autonomy in marine robots. A brief history of this emerging field is provided, along with a discussion of the challenges unique to the underwater environment and their impact on the level of intelligent autonomy required.  Topics covered at length examine advanced frameworks, path-planning, fault tolerance, machine learning, and cooperation as relevant to marine robots that need intelligent autonomy.  This book also: Discusses and offers solutions for the unique challenges presented by more complex missions and the dynamic underwater environment when operating autonomous marine robots Includes case studies that demonstrate intelligent autonomy in marine robots to perform underwater simultaneous localization and mapping  Autonomy for Marine Robots is an ideal book for researchers and engineers interested in the field of marine robots.      

  6. Conversion of alkyl radicals to allyl radicals in irradiated single crystal mats of polyethylene

    International Nuclear Information System (INIS)

    Fujimura, T.; Hayakawa, N.; Kuriyama, I.

    1978-01-01

    The decay of alkyl radicals, the conversion of alkyl radicals to allyl radicals and the trapping of allyl radicals in irradiated single crystal mats of polyethylene have been studied by electron spin resonance (e.s.r.). It has been suggested that in the crystal core alkyl radicals react with trans-vinylene double bonds and are converted into trans-vinylene allyl radicals; at the crystal surface, alkyl radicals react with vinyl end groups and are converted into allyl radicals with vinyl end groups. The decay of radical pairs and the formation of trans-vinylene double bonds are discussed. (author)

  7. Industrial Robots.

    Science.gov (United States)

    Reed, Dean; Harden, Thomas K.

    Robots are mechanical devices that can be programmed to perform some task of manipulation or locomotion under automatic control. This paper discusses: (1) early developments of the robotics industry in the United States; (2) the present structure of the industry; (3) noneconomic factors related to the use of robots; (4) labor considerations…

  8. Social Robots

    DEFF Research Database (Denmark)

    Social robotics is a cutting edge research area gathering researchers and stakeholders from various disciplines and organizations. The transformational potential that these machines, in the form of, for example, caregiving, entertainment or partner robots, pose to our societies and to us as indiv......Social robotics is a cutting edge research area gathering researchers and stakeholders from various disciplines and organizations. The transformational potential that these machines, in the form of, for example, caregiving, entertainment or partner robots, pose to our societies and to us...... as individuals seems to be limited by our technical limitations and phantasy alone. This collection contributes to the field of social robotics by exploring its boundaries from a philosophically informed standpoint. It constructively outlines central potentials and challenges and thereby also provides a stable...

  9. Non-manufacturing applications of robotics

    International Nuclear Information System (INIS)

    Dauchez, P.

    2000-12-01

    This book presents the different non-manufacturing sectors of activity where robotics can have useful or necessary applications: underwater robotics, agriculture robotics, road work robotics, nuclear robotics, medical-surgery robotics, aids to disabled people, entertainment robotics. Service robotics has been voluntarily excluded because this developing sector is not mature yet. (J.S.)

  10. Guest Editorial: Processes of Radicalization and De-Radicalization

    Directory of Open Access Journals (Sweden)

    Donatella Della Porta

    2012-05-01

    Full Text Available The study of radicalization and de-radicalization, understood as processes leading towards the increased or decreased use of political violence, is central to the question of how political violence emerges, how it can be prevented, and how it can be contained. The focus section of this issue of the International Journal of Conflict and Violence addresses radicalization and de-radicalization, seeking to develop a more comprehensive understanding of the processes, dynamics, and mechanisms involved and taking an interdisciplinary approach to overcome the fragmentation into separate disciplines and focus areas. Contributions by Pénélope Larzillière, Felix Heiduk, Bill Kissane, Hank Johnston, Christian Davenport and Cyanne Loyle, Veronique Dudouet, and Lasse Lindekilde address repressive settings, legitimacy, institutional aspects, organizational outcomes, and dynamics in Europe, Asia, Africa, and North and South America.

  11. Advanced robot locomotion.

    Energy Technology Data Exchange (ETDEWEB)

    Neely, Jason C.; Sturgis, Beverly Rainwater; Byrne, Raymond Harry; Feddema, John Todd; Spletzer, Barry Louis; Rose, Scott E.; Novick, David Keith; Wilson, David Gerald; Buerger, Stephen P.

    2007-01-01

    This report contains the results of a research effort on advanced robot locomotion. The majority of this work focuses on walking robots. Walking robot applications include delivery of special payloads to unique locations that require human locomotion to exo-skeleton human assistance applications. A walking robot could step over obstacles and move through narrow openings that a wheeled or tracked vehicle could not overcome. It could pick up and manipulate objects in ways that a standard robot gripper could not. Most importantly, a walking robot would be able to rapidly perform these tasks through an intuitive user interface that mimics natural human motion. The largest obstacle arises in emulating stability and balance control naturally present in humans but needed for bipedal locomotion in a robot. A tracked robot is bulky and limited, but a wide wheel base assures passive stability. Human bipedal motion is so common that it is taken for granted, but bipedal motion requires active balance and stability control for which the analysis is non-trivial. This report contains an extensive literature study on the state-of-the-art of legged robotics, and it additionally provides the analysis, simulation, and hardware verification of two variants of a proto-type leg design.

  12. Metal-catalyzed living radical polymerization and radical polyaddition for precision polymer synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Mizutani, M; Satoh, K [Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kamigaito, M, E-mail: kamigait@apchem.nagoya-u.ac.j

    2009-08-01

    The metal-catalyzed radical addition reaction can be evolved into two different polymerization mechanisms, i.e.; chain- and step-growth polymerizations, while both the polymerizations are based on the same metal-catalyzed radical formation reaction. The former is a widely employed metal-catalyzed living radical polymerization or atom transfer radical polymerization of common vinyl monomers, and the latter is a novel metal-catalyzed radical polyaddition of designed monomer with an unconjugated C=C double bond and a reactive C-Cl bond in one molecule. The simultaneous ruthenium-catalyzed living radical polymerization of methyl acrylate and radical polyaddition of 3-butenyl 2-chloropropionate was achieved with Ru(Cp*)Cl(PPh{sub 3}){sub 2} to afford the controlled polymers, in which the homopolymer segments with the controlled chain length were connected by the ester linkage.

  13. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    Science.gov (United States)

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  15. Robotic radiotherapy for prostate cancer with CyberKnife

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Benezery, K.; Bondiau, P.Y.; Marcie, S.; Gerard, J.P.; Chamorey, E.

    2007-01-01

    After 3D conformal radiation therapy without and with modulated intensity, image-guided radiation therapy represents a new technological step. Should prostate cancer treatment using radiotherapy with the CyberKnife robotic system be considered as a new treatment and then investigated through classical clinical research procedure rather than a technical improvement of an already validated treatment? After a general presentation of the CyberKnife, the authors focused on prostate cancer treatment assuming that, according to dosimetric and biological considerations, the treatment by robotic system appears comparable to high dose rate brachytherapy. For prostate cancer treatment are discussed: biological rational for hypo fractionated treatment, high dose rate brachytherapy boost and interest of dose escalation. A comparison is presented between CyberKnife and other validated treatment for prostate cancer (radical prostatectomy, 3D conformal radiation therapy and low and high dose rate brachytherapy). In summary, CyberKnife treatment could be considered as a technical improvement of an already validated treatment in order to deliver a prostate boost after pelvic or peri-prostatic area irradiation. However, the clinical, biological and economical results must be precisely analyzed and could be assessed in the frame of a National Observatory based on shared therapeutic program. (authors)

  16. Human-Robot Interaction

    Science.gov (United States)

    Sandor, Aniko; Cross, E. Vincent, II; Chang, Mai Lee

    2015-01-01

    Human-robot interaction (HRI) is a discipline investigating the factors affecting the interactions between humans and robots. It is important to evaluate how the design of interfaces affect the human's ability to perform tasks effectively and efficiently when working with a robot. By understanding the effects of interface design on human performance, workload, and situation awareness, interfaces can be developed to appropriately support the human in performing tasks with minimal errors and with appropriate interaction time and effort. Thus, the results of research on human-robot interfaces have direct implications for the design of robotic systems. For efficient and effective remote navigation of a rover, a human operator needs to be aware of the robot's environment. However, during teleoperation, operators may get information about the environment only through a robot's front-mounted camera causing a keyhole effect. The keyhole effect reduces situation awareness which may manifest in navigation issues such as higher number of collisions, missing critical aspects of the environment, or reduced speed. One way to compensate for the keyhole effect and the ambiguities operators experience when they teleoperate a robot is adding multiple cameras and including the robot chassis in the camera view. Augmented reality, such as overlays, can also enhance the way a person sees objects in the environment or in camera views by making them more visible. Scenes can be augmented with integrated telemetry, procedures, or map information. Furthermore, the addition of an exocentric (i.e., third-person) field of view from a camera placed in the robot's environment may provide operators with the additional information needed to gain spatial awareness of the robot. Two research studies investigated possible mitigation approaches to address the keyhole effect: 1) combining the inclusion of the robot chassis in the camera view with augmented reality overlays, and 2) modifying the camera

  17. Optimum path planning of mobile robot in unknown static and dynamic environments using Fuzzy-Wind Driven Optimization algorithm

    Directory of Open Access Journals (Sweden)

    Anish Pandey

    2017-02-01

    Full Text Available This article introduces a singleton type-1 fuzzy logic system (T1-SFLS controller and Fuzzy-WDO hybrid for the autonomous mobile robot navigation and collision avoidance in an unknown static and dynamic environment. The WDO (Wind Driven Optimization algorithm is used to optimize and tune the input/output membership function parameters of the fuzzy controller. The WDO algorithm is working based on the atmospheric motion of infinitesimal small air parcels navigates over an N-dimensional search domain. The performance of this proposed technique has compared through many computer simulations and real-time experiments by using Khepera-III mobile robot. As compared to the T1-SFLS controller the Fuzzy-WDO algorithm is found good agreement for mobile robot navigation.

  18. Automated Planning Enables Complex Protocols on Liquid-Handling Robots.

    Science.gov (United States)

    Whitehead, Ellis; Rudolf, Fabian; Kaltenbach, Hans-Michael; Stelling, Jörg

    2018-03-16

    Robotic automation in synthetic biology is especially relevant for liquid handling to facilitate complex experiments. However, research tasks that are not highly standardized are still rarely automated in practice. Two main reasons for this are the substantial investments required to translate molecular biological protocols into robot programs, and the fact that the resulting programs are often too specific to be easily reused and shared. Recent developments of standardized protocols and dedicated programming languages for liquid-handling operations addressed some aspects of ease-of-use and portability of protocols. However, either they focus on simplicity, at the expense of enabling complex protocols, or they entail detailed programming, with corresponding skills and efforts required from the users. To reconcile these trade-offs, we developed Roboliq, a software system that uses artificial intelligence (AI) methods to integrate (i) generic formal, yet intuitive, protocol descriptions, (ii) complete, but usually hidden, programming capabilities, and (iii) user-system interactions to automatically generate executable, optimized robot programs. Roboliq also enables high-level specifications of complex tasks with conditional execution. To demonstrate the system's benefits for experiments that are difficult to perform manually because of their complexity, duration, or time-critical nature, we present three proof-of-principle applications for the reproducible, quantitative characterization of GFP variants.

  19. Next generation light robotic

    DEFF Research Database (Denmark)

    Villangca, Mark Jayson; Palima, Darwin; Banas, Andrew Rafael

    2017-01-01

    -assisted surgery imbibes surgeons with superhuman abilities and gives the expression “surgical precision” a whole new meaning. Still in its infancy, much remains to be done to improve human-robot collaboration both in realizing robots that can operate safely with humans and in training personnel that can work......Conventional robotics provides machines and robots that can replace and surpass human performance in repetitive, difficult, and even dangerous tasks at industrial assembly lines, hazardous environments, or even at remote planets. A new class of robotic systems no longer aims to replace humans...... with so-called automatons but, rather, to create robots that can work alongside human operators. These new robots are intended to collaborate with humans—extending their abilities—from assisting workers on the factory floor to rehabilitating patients in their homes. In medical robotics, robot...

  20. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Directory of Open Access Journals (Sweden)

    Kristel Knaepen

    Full Text Available In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support. Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  1. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Science.gov (United States)

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  2. Roles and Self-Reconfigurable Robots

    DEFF Research Database (Denmark)

    Dvinge, Nicolai; Schultz, Ulrik Pagh; Christensen, David Johan

    2007-01-01

    A self-reconfigurable robot is a robotic device that can change its own shape. Self-reconfigurable robots are commonly built from multiple identical modules that can manipulate each other to change the shape of the robot. The robot can also perform tasks such as locomotion without changing shape......., significantly simplifying the task of programming self-reconfigurable robots. Our language fully supports programming the ATRON self-reconfigurable robot, and has been used to implement several controllers running both on the physical modules and in simulation.......A self-reconfigurable robot is a robotic device that can change its own shape. Self-reconfigurable robots are commonly built from multiple identical modules that can manipulate each other to change the shape of the robot. The robot can also perform tasks such as locomotion without changing shape....... Programming a modular, self-reconfigurable robot is however a complicated task: the robot is essentially a real-time, distributed embedded system, where control and communication paths often are tightly coupled to the current physical configuration of the robot. To facilitate the task of programming modular...

  3. Solution phase and membrane immobilized iron-based free radical reactions: Fundamentals and applications for water treatment

    Science.gov (United States)

    Lewis, Scott Romak

    Membrane-based separation processes have been used extensively for drinking water purification, wastewater treatment, and numerous other applications. Reactive membranes synthesized through functionalization of the membrane pores offer enhanced reactivity due to increased surface area at the polymer-solution interface and low diffusion limitations. Oxidative techniques utilizing free radicals have proven effective for both the destruction of toxic organics and non-environmental applications. Most previous work focuses on reactions in the homogeneous phase; however, the immobilization of reactants in membrane pores offers several advantages. The use of polyanions immobilized in a membrane or chelates in solution prevents ferric hydroxide precipitation at near-neutral pH, a common limitation of iron(Fe(II/III))-catalyzed hydrogen peroxide (H 2O2) decomposition. The objectives of this research are to develop a membrane-based platform for the generation of free radicals, degrade toxic organic compounds using this and similar solution-based reactions, degrade toxic organic compounds in droplet form, quantify hydroxyl radical production in these reactions, and develop kinetic models for both processes. In this study, a functionalized membrane containing poly(acrylic acid) (PAA) was used to immobilize iron ions and conduct free radical reactions by permeating H2O2 through the membrane. The membrane's responsive behavior to pH and divalent cations was investigated and modeled. The conversion of Fe(II) to Fe(III) in the membrane and its effect on the decomposition of hydrogen peroxide were monitored and used to develop kinetic models for predicting H2O2 decomposition in these systems. The rate of hydroxyl radical production, and hence contaminant degradation can be varied by changing the residence time, H2O2 concentration, and/or iron loading. Using these membrane-immobilized systems, successful removal of toxic organic compounds, such as pentachlorophenol (PCP), from water

  4. Robot Teachers

    DEFF Research Database (Denmark)

    Nørgård, Rikke Toft; Ess, Charles Melvin; Bhroin, Niamh Ni

    The world's first robot teacher, Saya, was introduced to a classroom in Japan in 2009. Saya, had the appearance of a young female teacher. She could express six basic emotions, take the register and shout orders like 'be quiet' (The Guardian, 2009). Since 2009, humanoid robot technologies have...... developed. It is now suggested that robot teachers may become regular features in educational settings, and may even 'take over' from human teachers in ten to fifteen years (cf. Amundsen, 2017 online; Gohd, 2017 online). Designed to look and act like a particular kind of human; robot teachers mediate human...... existence and roles, while also aiming to support education through sophisticated, automated, human-like interaction. Our paper explores the design and existential implications of ARTIE, a robot teacher at Oxford Brookes University (2017, online). Drawing on an initial empirical exploration we propose...

  5. Accelerating Robot Development through Integral Analysis of Human-Robot Interaction

    NARCIS (Netherlands)

    Kooijmans, T.; Kanda, T.; Bartneck, C.; Ishiguro, H.; Hagita, N.

    2007-01-01

    The development of interactive robots is a complicated process, involving a plethora of psychological, technical, and contextual influences. To design a robot capable of operating "intelligently" in everyday situations, one needs a profound understanding of human-robot interaction (HRI). We propose

  6. Micro Robotics Lab

    Data.gov (United States)

    Federal Laboratory Consortium — Our research is focused on the challenges of engineering robotic systems down to sub-millimeter size scales. We work both on small mobile robots (robotic insects for...

  7. Robot fish bio-inspired fishlike underwater robots

    CERN Document Server

    Li, Zheng; Youcef-Toumi, Kamal; Alvarado, Pablo

    2015-01-01

    This book provides a comprehensive coverage on robot fish including design, modeling and optimization, control, autonomous control and applications. It gathers contributions by the leading researchers in the area. Readers will find the book very useful for designing and building robot fish, not only in theory but also in practice. Moreover, the book discusses various important issues for future research and development, including design methodology, control methodology, and autonomous control strategy. This book is intended for researchers and graduate students in the fields of robotics, ocean engineering and related areas.

  8. Robotics in endoscopy.

    Science.gov (United States)

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  9. Implementation and Reconfiguration of Robot Operating System on Human Follower Transporter Robot

    Directory of Open Access Journals (Sweden)

    Addythia Saphala

    2015-10-01

    Full Text Available Robotic Operation System (ROS is an im- portant platform to develop robot applications. One area of applications is for development of a Human Follower Transporter Robot (HFTR, which  can  be  considered  as a custom mobile robot utilizing differential driver steering method and equipped with Kinect sensor. This study discusses the development of the robot navigation system by implementing Simultaneous Localization and Mapping (SLAM.

  10. The Rh-1 Full-Size Humanoid Robot: Design, Walking Pattern Generation and Control

    Directory of Open Access Journals (Sweden)

    M. Arbulú

    2009-01-01

    Full Text Available This paper is an overview of the humanoid robot Rh-1, the second phase of the Rh project, which was launched by the Robotics Lab at the Carlos III University of Madrid in 2002. The robot mechanical design includes the specifications development in order to construct a platform, which is capable of stable biped walking. At first, the robots’ weights were calculated in order to obtain the inverse dynamics and to select the actuators. After that, mechanical specifications were introduced in order to verify the robot’s structural behaviour with different experimental gaits. In addition, an important aspect is the joints design when their axes are crossed, which is called ‘Joints of Rectangular Axes’ (JRA. The problem with these joints is obtaining two or more degrees of freedom (DOF in small space. The construction of a humanoid robot also includes the design of hardware and software architectures. The main advantage of the proposed hardware and software architectures is the use of standardised solutions frequently used in the automation industry and commercially available hardware components. It provides scalability, modularity and application of standardised interfaces and brings the design of the complex control system of the humanoid robot out of a closed laboratory to industry. Stable walking is the most essential ability for the humanoid robot. The three dimensional Linear Inverted Pendulum Model (3D-LIPM and the Cart-table models had been used in order to achieve natural and dynamic biped walking. Humanoid dynamics is widely simplified by concentrating its mass in the centre of gravity (COG and moving it following the natural inverted pendulum laws (3D-LIPM or by controlling the cart motion (Cart-table model. An offline-calculated motion pattern does not guarantee the walking stability of the humanoid robot. Control architecture for the dynamic humanoid robot walking was developed, which is able to make online modifications of the

  11. Presentation robot Advee

    Czech Academy of Sciences Publication Activity Database

    Krejsa, Jiří; Věchet, Stanislav; Hrbáček, J.; Ripel, T.; Ondroušek, V.; Hrbáček, R.; Schreiber, P.

    2012-01-01

    Roč. 18, 5/6 (2012), s. 307-322 ISSN 1802-1484 Institutional research plan: CEZ:AV0Z20760514 Keywords : mobile robot * human - robot interface * localization Subject RIV: JD - Computer Applications, Robot ics

  12. Magnetic Resonance Studies of Proton Loss from Carotenoid Radical Cations

    International Nuclear Information System (INIS)

    Kispert, Lowell D.; Focsan, A. Ligia; Konovalova, Tatyana A.; Lawrence, Jesse; Bowman, Michael K.; Dixon, David A.; Molnar, Peter; Deli, Jozsef

    2007-01-01

    Carotenoids, intrinsic components of reaction centers and pigment-protein complexes in photosynthetic membranes, play a photoprotective role and serve as a secondary electron donor. Before optimum use of carotenoids can be made in artificial photosynthetic systems, their robust nature in living materials requires extensive characterization of their electron transfer, radical trapping ability, stability, structure in and on various hosts, and photochemical behavior. Pulsed ENDOR and 2D-HYSCORE studies combined with DFT calculations reveal that photo-oxidation of natural zeaxanthin (I) and violaxanthin (II) on silica-alumina produces not only the carotenoid radical cations (Car ·+ ) but also neutral radicals ((number s ign)Car · ) by proton loss from the methyl groups at positions 5 or 5(prime), and possibly 9 or 9(prime) and 13 or 13(prime). Notably, the proton loss favored in I at the 5 position by DFT calculations, is unfavorable in II due to the epoxide at the 5, 6 position. DFT calculations predict the isotropic methyl proton couplings of 8-10 MHz for Car # center d ot# + which agree with the ENDOR for carotenoid π-conjugated radical cations. Large α-proton hyperfine coupling constants (>10 MHz) determined from HYSCORE are assigned from the DFT calculations to neutral carotenoid radicals. Proton loss upon photolysis was also examined as a function of carotenoid polarity (Lycopene (III) versus 8(prime)-apo-β-caroten-8(prime)-al (IV)); hydrogen bonding (Lutein (V) versus III); host (silica-alumina versus MCM-41 molecular sieve); and substituted metal in MCM-41. Loss of H + from the 5(5(prime)), 9(9(prime)) or 13(13(prime)) methyl positions has importance in photoprotection. Photoprotection involves nonphotochemical quenching (NPQ) in which 1 Ch1* decays via energy transfer to the carotenoid which returns to the ground state by thermal dissipation; or via electron transfer to form a charge transfer state (I # center d ot# + ...Chl # center d ot# - ), lower in

  13. Robotic surgery update.

    Science.gov (United States)

    Jacobsen, G; Elli, F; Horgan, S

    2004-08-01

    Minimally invasive surgical techniques have revolutionized the field of surgery. Telesurgical manipulators (robots) and new information technologies strive to improve upon currently available minimally invasive techniques and create new possibilities. A retrospective review of all robotic cases at a single academic medical center from August 2000 until November 2002 was conducted. A comprehensive literature evaluation on robotic surgical technology was also performed. Robotic technology is safely and effectively being applied at our institution. Robotic and information technologies have improved upon minimally invasive surgical techniques and created new opportunities not attainable in open surgery. Robotic technology offers many benefits over traditional minimal access techniques and has been proven safe and effective. Further research is needed to better define the optimal application of this technology. Credentialing and educational requirements also need to be delineated.

  14. Robot-laser system

    International Nuclear Information System (INIS)

    Akeel, H.A.

    1987-01-01

    A robot-laser system is described for providing a laser beam at a desired location, the system comprising: a laser beam source; a robot including a plurality of movable parts including a hollow robot arm having a central axis along which the laser source directs the laser beam; at least one mirror for reflecting the laser beam from the source to the desired location, the mirror being mounted within the robot arm to move therewith and relative thereto to about a transverse axis that extends angularly to the central axis of the robot arm; and an automatic programmable control system for automatically moving the mirror about the transverse axis relative to and in synchronization with movement of the robot arm to thereby direct the laser beam to the desired location as the arm is moved

  15. Effects of Robot Facial Characteristics and Gender in Persuasive Human-Robot Interaction

    Directory of Open Access Journals (Sweden)

    Aimi S. Ghazali

    2018-06-01

    Full Text Available The growing interest in social robotics makes it relevant to examine the potential of robots as persuasive agents and, more specifically, to examine how robot characteristics influence the way people experience such interactions and comply with the persuasive attempts by robots. The purpose of this research is to identify how the (ostensible gender and the facial characteristics of a robot influence the extent to which people trust it and the psychological reactance they experience from its persuasive attempts. This paper reports a laboratory study where SociBot™, a robot capable of displaying different faces and dynamic social cues, delivered persuasive messages to participants while playing a game. In-game choice behavior was logged, and trust and reactance toward the advisor were measured using questionnaires. Results show that a robotic advisor with upturned eyebrows and lips (features that people tend to trust more in humans is more persuasive, evokes more trust, and less psychological reactance compared to one displaying eyebrows pointing down and lips curled downwards at the edges (facial characteristics typically not trusted in humans. Gender of the robot did not affect trust, but participants experienced higher psychological reactance when interacting with a robot of the opposite gender. Remarkably, mediation analysis showed that liking of the robot fully mediates the influence of facial characteristics on trusting beliefs and psychological reactance. Also, psychological reactance was a strong and reliable predictor of trusting beliefs but not of trusting behavior. These results suggest robots that are intended to influence human behavior should be designed to have facial characteristics we trust in humans and could be personalized to have the same gender as the user. Furthermore, personalization and adaptation techniques designed to make people like the robot more may help ensure they will also trust the robot.

  16. Robotic seeding

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus; Fountas, Spyros; Sørensen, Claus Aage Grøn

    2017-01-01

    Agricultural robotics has received attention for approximately 20 years, but today there are only a few examples of the application of robots in agricultural practice. The lack of uptake may be (at least partly) because in many cases there is either no compelling economic benefit......, or there is a benefit but it is not recognized. The aim of this chapter is to quantify the economic benefits from the application of agricultural robots under a specific condition where such a benefit is assumed to exist, namely the case of early seeding and re-seeding in sugar beet. With some predefined assumptions...... with regard to speed, capacity and seed mapping, we found that among these two technical systems both early seeding with a small robot and re-seeding using a robot for a smaller part of the field appear to be financially viable solutions in sugar beet production....

  17. An Adaptive Robot Game

    DEFF Research Database (Denmark)

    Hansen, Søren Tranberg; Svenstrup, Mikael; Dalgaard, Lars

    2010-01-01

    The goal of this paper is to describe an adaptive robot game, which motivates elderly people to do a regular amount of physical exercise while playing. One of the advantages of robot based games is that the initiative to play can be taken autonomously by the robot. In this case, the goal is to im......The goal of this paper is to describe an adaptive robot game, which motivates elderly people to do a regular amount of physical exercise while playing. One of the advantages of robot based games is that the initiative to play can be taken autonomously by the robot. In this case, the goal...... is to improve the mental and physical state of the user by playing a physical game with the robot. Ideally, a robot game should be simple to learn but difficult to master, providing an appropriate degree of challenge for players with different skills. In order to achieve that, the robot should be able to adapt...

  18. Facilitating Programming of Vision-Equipped Robots through Robotic Skills and Projection Mapping

    DEFF Research Database (Denmark)

    Andersen, Rasmus Skovgaard

    The field of collaborative industrial robots is currently developing fast both in the industry and in the scientific community. Companies such as Rethink Robotics and Universal Robots are redefining the concept of an industrial robot and entire new markets and use cases are becoming relevant for ...

  19. N-tert-butylmethanimine N-oxide is an efficient spin-trapping probe for EPR analysis of glutathione thiyl radical

    Science.gov (United States)

    Scott, Melanie J.; Billiar, Timothy R.; Stoyanovsky, Detcho A.

    2016-01-01

    The electron spin resonance (EPR) spin-trapping technique allows detection of radical species with nanosecond half-lives. This technique is based on the high rates of addition of radicals to nitrones or nitroso compounds (spin traps; STs). The paramagnetic nitroxides (spin-adducts) formed as a result of reactions between STs and radical species are relatively stable compounds whose EPR spectra represent “structural fingerprints” of the parent radical species. Herein we report a novel protocol for the synthesis of N-tert-butylmethanimine N-oxide (EBN), which is the simplest nitrone containing an α-H and a tertiary α′-C atom. We present EPR spin-trapping proof that: (i) EBN is an efficient probe for the analysis of glutathione thiyl radical (GS•); (ii) β-cyclodextrins increase the kinetic stability of the spin-adduct EBN/•SG; and (iii) in aqueous solutions, EBN does not react with superoxide anion radical (O2−•) to form EBN/•OOH to any significant extent. The data presented complement previous studies within the context of synthetic accessibility to EBN and efficient spin-trapping analysis of GS•. PMID:27941944

  20. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  1. Advanced mechanics in robotic systems

    CERN Document Server

    Nava Rodríguez, Nestor Eduardo

    2011-01-01

    Illustrates original and ambitious mechanical designs and techniques for the development of new robot prototypes Includes numerous figures, tables and flow charts Discusses relevant applications in robotics fields such as humanoid robots, robotic hands, mobile robots, parallel manipulators and human-centred robots

  2. Design and Implementation of Fire Extinguisher Robot with Robotic Arm

    Directory of Open Access Journals (Sweden)

    Memon Abdul Waris

    2018-01-01

    Full Text Available Robot is a device, which performs human task or behave like a human-being. It needs expertise skills and complex programming to design. For designing a fire fighter robot, many sensors and motors were used. User firstly send robot to an affected area, to get live image of the field with the help of mobile camera via Wi-Fi using IP camera application to laptop. If any signs of fire shown in image, user direct robot in that particular direction for confirmation. Fire sensor and temperature sensor detects and measures the reading, after confirmation robot sprinkle water on affected field. During extinguish process if any obstacle comes in between the prototype and the affected area the ultrasonic sensor detects the obstacle, in response the robotic arm moves to pick and place that obstacle to another location for clearing the path. Meanwhile if any poisonous gas is present, the gas sensor detects and indicates by making alarm.

  3. The Tactile Ethics of Soft Robotics: Designing Wisely for Human-Robot Interaction.

    Science.gov (United States)

    Arnold, Thomas; Scheutz, Matthias

    2017-06-01

    Soft robots promise an exciting design trajectory in the field of robotics and human-robot interaction (HRI), promising more adaptive, resilient movement within environments as well as a safer, more sensitive interface for the objects or agents the robot encounters. In particular, tactile HRI is a critical dimension for designers to consider, especially given the onrush of assistive and companion robots into our society. In this article, we propose to surface an important set of ethical challenges for the field of soft robotics to meet. Tactile HRI strongly suggests that soft-bodied robots balance tactile engagement against emotional manipulation, model intimacy on the bonding with a tool not with a person, and deflect users from personally and socially destructive behavior the soft bodies and surfaces could normally entice.

  4. Spectroscopy, Kinetics, and Dynamics of Combustion Radicals

    Energy Technology Data Exchange (ETDEWEB)

    Nesbitt, David J. [Research/Professor

    2013-08-06

    Spectroscopy, kinetics and dynamics of jet cooled hydrocarbon transients relevant to the DOE combustion mission have been explored, exploiting i) high resolution IR lasers, ii) slit discharge sources for formation of jet cooled radicals, and iii) high sensitivity detection with direct laser absorption methods and near the quantum shot noise limit. What makes this combination powerful is that such transients can be made under high concentrations and pressures characteristic of actual combustion conditions, and yet with the resulting species rapidly cooled (T ≈10-15K) in the slit supersonic expansion. Combined with the power of IR laser absorption methods, this provides novel access to spectral detection and study of many critical combustion species.

  5. Evaluation of perioperative complications and outcomes of robot-assisted radical nephroureterectomy and bladder cuff excision in a tertiary center

    Directory of Open Access Journals (Sweden)

    Meng-Che Tai

    2018-01-01

    Full Text Available Purpose: For patients with localized upper tract urothelial carcinoma (UTUC, radical nephroureterectomy with ipsilateral bladder cuff excision (RNU + BCE is the standard treatment. In recent years, robot-assisted RNU with BCE (RaRNU + BCE has been another choice of surgical intervention. This article was aimed to analyze the efficacy and perioperative outcomes regarding RaRNU + BCE through a single institutional experience. Patients and Methods: From March 2012 to November 2015, a total of 54 patients with UTUC were treated with RaRNU + BCE at Taipei Veterans General Hospital. We collected demographic data, histopathological reports, perioperative complications, and oncologic outcomes. Results: A total of 54 patients were included in our study. The mean age was 71.9 ± 9.9 (range 48–88 and the mean body mass index was 23.5 ± 2.9 (range: 16.4–30.8. The mean operating time was 314 min (RaRNU: 133.9 ± 41.4 min and RaBCE: 72.9 ± 25.7 min. The mean first docking time was 26.8 ± 7.7 min and the mean second docking time was 16.5 ± 6.7 min. The mean EBL was 87.7 ml. Pathological stage distribution was 22.2%, 27.8%, 13.0%, 31.5%, and 5.6% in pTa, pT1, pT2, pT3, and pT4, respectively. Complications occurred in 7 cases (13%, with 4 Grade I and 3 Grade II by Clavien-Dindo classification. Positive tumor involvement at bladder cuff was noted in three patients, and the bladder recurrence rate was 29.6%. Local recurrence, lymph node metastasis, and distant metastasis were all noted for two patients, respectively. The cancer-specific and overall survival rate was 98.1% and 96.3%. Conclusions: Our experience showed that RaRNU + BCE is a technically feasible and safe procedure for selected patients with UTUC.

  6. Robotic 3D SQUID imaging system for practical nondestructive evaluation applications

    International Nuclear Information System (INIS)

    Isawa, K.; Nakayama, S.; Ikeda, M.; Takagi, S.; Tosaka, S.; Kasai, N.

    2005-01-01

    A robotic three-dimensional (3D) scanning superconducting quantum interference device (SQUID) imaging system was developed for practical nondestructive evaluation (NDE) applications. The major feature of this SQUID-NDE system is that the SQUID sensor itself scans in 3D by traveling over the surface of an object during testing without the need for magnetic shielding. This imaging system consists of (i) DC-SQUID gradiometer for effective movement of the sensor, (ii) SQUID sensor manipulator utilizing an articulated-type robot used in industry, (iii) laser charge-coupled-device (CCD) displacement sensor to measure the 3D coordinates of points on the surface of the object, and (iv) computer-aided numerical interpolation scheme for 3D surface reconstruction of the object. The applicability of this system for NDE was demonstrated by successfully detecting artificial damage of cylindrical-shaped steel tubes

  7. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  8. Robot-assisted partial nephrectomy in contemporary practice

    Energy Technology Data Exchange (ETDEWEB)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S., E-mail: tanaghoy@wudosis.wustl.edu [Division of Urologic Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2013-01-11

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  9. Robot-assisted partial nephrectomy in contemporary practice

    International Nuclear Information System (INIS)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S.

    2013-01-01

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  10. Grasping in Robotics

    CERN Document Server

    2013-01-01

    Grasping in Robotics contains original contributions in the field of grasping in robotics with a broad multidisciplinary approach. This gives the possibility of addressing all the major issues related to robotized grasping, including milestones in grasping through the centuries, mechanical design issues, control issues, modelling achievements and issues, formulations and software for simulation purposes, sensors and vision integration, applications in industrial field and non-conventional applications (including service robotics and agriculture).   The contributors to this book are experts in their own diverse and wide ranging fields. This multidisciplinary approach can help make Grasping in Robotics of interest to a very wide audience. In particular, it can be a useful reference book for researchers, students and users in the wide field of grasping in robotics from many different disciplines including mechanical design, hardware design, control design, user interfaces, modelling, simulation, sensors and hum...

  11. Designing Emotionally Expressive Robots

    DEFF Research Database (Denmark)

    Tsiourti, Christiana; Weiss, Astrid; Wac, Katarzyna

    2017-01-01

    Socially assistive agents, be it virtual avatars or robots, need to engage in social interactions with humans and express their internal emotional states, goals, and desires. In this work, we conducted a comparative study to investigate how humans perceive emotional cues expressed by humanoid...... robots through five communication modalities (face, head, body, voice, locomotion) and examined whether the degree of a robot's human-like embodiment affects this perception. In an online survey, we asked people to identify emotions communicated by Pepper -a highly human-like robot and Hobbit – a robot...... for robots....

  12. Return to work following robot-assisted laparoscopic and open retropubic radical prostatectomy: A single-center cohort study to compare duration of sick leave.

    Science.gov (United States)

    von Mechow, Stefanie; Graefen, Markus; Haese, Alexander; Tennstedt, Pierre; Pehrke, Dirk; Friedersdorff, Frank; Beyer, Burkhard

    2018-06-01

    To compare the duration of sick leave in patients with localized prostate cancer after robot-assisted radical prostatectomy (RARP) and open retropubic RP (ORP) at a German high-volume prostate cancer center. The data of 1,415 patients treated with RP at Martini Klinik, Prostate Cancer Center between 2012 and 2016 were, retrospectively, analyzed. Information on employment status, monthly revenues and days of work missed due to sickness were assessed via online questionnaire. Additional data were retrieved from our institutional database. Medians and interquartile ranges (IQR) were reported for continuous data. Cox proportional hazard analysis was performed to compare both surgical techniques for return to work time after RP. Median time elapsed between surgery and return to work comprised 42 days in patients undergoing RARP (IQR: 21-70) and ORP (IQR: 28-84, P = 0.05). In Cox regression analysis, surgical approach showed no impact on return to work time (RARP vs. ORP hazard ratio = 1, 95% CI: 0.91-1.16, P = 0.69). Return to work time was significantly associated with employment status, physical workload and monthly income (all PLimitation of this study is the nonrandomized design in a single-center. As the surgical approach did not show any influence on the number of days missed from work in patients undergoing RP, no superiority of either RARP or ORP could be identified for return to work time in a German cohort. Both surgical approaches are safe options usually allowing the patients to resume normal activities including work after an appropriate convalescence period. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Radical Change by Entrepreneurial Design

    National Research Council Canada - National Science Library

    Roberts, Nancy C

    1998-01-01

    .... How radical change in public policy has occurred in the past is then documented. We find examples of radical change by chance, radical change by consensus, radical change by learning, and radical change by entrepreneurial design...

  14. Fundamentals of soft robot locomotion.

    Science.gov (United States)

    Calisti, M; Picardi, G; Laschi, C

    2017-05-01

    Soft robotics and its related technologies enable robot abilities in several robotics domains including, but not exclusively related to, manipulation, manufacturing, human-robot interaction and locomotion. Although field applications have emerged for soft manipulation and human-robot interaction, mobile soft robots appear to remain in the research stage, involving the somehow conflictual goals of having a deformable body and exerting forces on the environment to achieve locomotion. This paper aims to provide a reference guide for researchers approaching mobile soft robotics, to describe the underlying principles of soft robot locomotion with its pros and cons, and to envisage applications and further developments for mobile soft robotics. © 2017 The Author(s).

  15. Acceptance, Prevalence and Indications for Robot-Assisted Laparoscopy - Results of a Survey Among Urologists in Germany, Austria and Switzerland.

    Science.gov (United States)

    Imkamp, Florian; Herrmann, Thomas R W; Tolkach, Yuri; Dziuba, Sebastian; Stolzenburg, Jens U; Rassweiler, Jens; Sulser, Tullio; Zimmermann, Uwe; Merseburger, Axel S; Kuczyk, Markus A; Burchardt, Martin

    2015-01-01

    Robotic-assisted laparoscopy (RAL) is being widely accepted in the field of urology as a replacement for conventional laparoscopy (CL). Nevertheless, the process of its integration in clinical routines has been rather spontaneous. To determine the prevalence of robotic systems (RS) in urological clinics in Germany, Austria and Switzerland, the acceptance of RAL among urologists as a replacement for CL and its current use for 25 different urological indications. To elucidate the practice patterns of RAL, a survey at hospitals in Germany, Austria and Switzerland was conducted. All surgically active urology departments in Germany (303), Austria (37) and Switzerland (84) received a questionnaire with questions related to the one-year period prior to the survey. The response rate was 63%. Among the participants, 43% were universities, 45% were tertiary care centres, and 8% were secondary care hospitals. A total of 60 RS (Germany 35, Austria 8, Switzerland 17) were available, and the majority (68%) were operated under public ownership. The perception of RAL and the anticipated superiority of RAL significantly differed between robotic and non-robotic surgeons. For only two urologic indications were more than 50% of the procedures performed using RAL: pyeloplasty (58%) and transperitoneal radical prostatectomy (75%). On average, 35% of robotic surgeons and only 14% of non-robotic surgeons anticipated RAL superiority in some of the 25 indications. This survey provides a detailed insight into RAL implementation in Germany, Austria and Switzerland. RAL is currently limited to a few urological indications with a small number of high-volume robotic centres. These results might suggest that a saturation of clinics using RS has been achieved but that the existing robotic capacities are being utilized ineffectively. The possible reasons for this finding are discussed, and certain strategies to solve these problems are offered. © 2015 S. Karger AG, Basel.

  16. Advancing the Strategic Messages Affecting Robot Trust Effect: The Dynamic of User- and Robot-Generated Content on Human-Robot Trust and Interaction Outcomes.

    Science.gov (United States)

    Liang, Yuhua Jake; Lee, Seungcheol Austin

    2016-09-01

    Human-robot interaction (HRI) will soon transform and shift the communication landscape such that people exchange messages with robots. However, successful HRI requires people to trust robots, and, in turn, the trust affects the interaction. Although prior research has examined the determinants of human-robot trust (HRT) during HRI, no research has examined the messages that people received before interacting with robots and their effect on HRT. We conceptualize these messages as SMART (Strategic Messages Affecting Robot Trust). Moreover, we posit that SMART can ultimately affect actual HRI outcomes (i.e., robot evaluations, robot credibility, participant mood) by affording the persuasive influences from user-generated content (UGC) on participatory Web sites. In Study 1, participants were assigned to one of two conditions (UGC/control) in an original experiment of HRT. Compared with the control (descriptive information only), results showed that UGC moderated the correlation between HRT and interaction outcomes in a positive direction (average Δr = +0.39) for robots as media and robots as tools. In Study 2, we explored the effect of robot-generated content but did not find similar moderation effects. These findings point to an important empirical potential to employ SMART in future robot deployment.

  17. The role of intraoperative ultrasound in small renal mass robotic enucleation

    Directory of Open Access Journals (Sweden)

    Roberta Gunelli

    2016-12-01

    Full Text Available Introduction: As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exophytic small renal mass. Materials and methods: A total of 22 robotic enucleations were performed on < 3 cm renal neoplasias (PADUA score 18 Pz 6/7 e 4 Pz 8 using a 12-5 MHz robotic ultrasound probe (BK Drop-In 8826. Results: Once kidney had been isolated from the adipose capsule at the site of the neoplasia (2, the exact position of the lesion could be easily identified in all cases (22/22, even for mostly endophytic lesions, thanks to the insertion of the ultrasound probe through the assistant port. Images were produced and visualized by the surgeon using the TilePro feature of the DaVinci surgical system for producing a picture-in-picture image on the console screen. The margins of resection were then marked with cautery, thus allowing for speedy anatomical dissection. This reduced the time of ischemia to 8 min (6-13 and facilitated the enucleation technique when performed without clamping the renal peduncle (6/22. No complications due to the use of the ultrasound probe were observed. Conclusions: The use of an intraoperative robotic ultrasound probe has allowed for easier identification of small, mostly endophytic neoplasias, better anatomical approach, shorter ischemic time, reduced risk of pseudocapsule rupture during dissection, and easier enucleation in cases performed without clamping. It is noteworthy that the use of intraoperative ultrasound probe allows mental reconstruction of the tumor through an accurate 3D vision of the hidden field during

  18. The role of intraoperative ultrasound in small renal mass robotic enucleation.

    Science.gov (United States)

    Gunelli, Roberta; Fiori, Massimo; Salaris, Cristiano; Salomone, Umberto; Urbinati, Marco; Vici, Alexia; Zenico, Teo; Bertocco, Mauro

    2016-12-30

    As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exophytic small renal mass. A total of 22 robotic enucleations were performed on < 3 cm renal neoplasias (PADUA score 18 Pz 6/7 e 4 Pz 8) using a 12-5 MHz robotic ultrasound probe (BK Drop-In 8826). Once kidney had been isolated from the adipose capsule at the site of the neoplasia (2), the exact position of the lesion could be easily identified in all cases (22/22), even for mostly endophytic lesions, thanks to the insertion of the ultrasound probe through the assistant port. Images were produced and visualized by the surgeon using the TilePro feature of the DaVinci surgical system for producing a picture-in-picture image on the console screen. The margins of resection were then marked with cautery, thus allowing for speedy anatomical dissection. This reduced the time of ischemia to 8 min (6-13) and facilitated the enucleation technique when performed without clamping the renal peduncle (6/22). No complications due to the use of the ultrasound probe were observed. The use of an intraoperative robotic ultrasound probe has allowed for easier identification of small, mostly endophytic neoplasias, better anatomical approach, shorter ischemic time, reduced risk of pseudocapsule rupture during dissection, and easier enucleation in cases performed without clamping. It is noteworthy that the use of intraoperative ultrasound probe allows mental reconstruction of the tumor through an accurate 3D vision of the hidden field during surgical dissection.

  19. Next-generation robotic surgery--from the aspect of surgical robots developed by industry.

    Science.gov (United States)

    Nakadate, Ryu; Arata, Jumpei; Hashizume, Makoto

    2015-02-01

    At present, much of the research conducted worldwide focuses on extending the ability of surgical robots. One approach is to extend robotic dexterity. For instance, accessibility and dexterity of the surgical instruments remains the largest issue for reduced port surgery such as single port surgery or natural orifice surgery. To solve this problem, a great deal of research is currently conducted in the field of robotics. Enhancing the surgeon's perception is an approach that uses advanced sensor technology. The real-time data acquired through the robotic system combined with the data stored in the robot (such as the robot's location) provide a major advantage. This paper aims at introducing state-of-the-art products and pre-market products in this technological advancement, namely the robotic challenge in extending dexterity and hopefully providing the path to robotic surgery in the near future.

  20. Humanlike Robots - The Upcoming Revolution in Robotics

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2009-01-01

    Humans have always sought to imitate the human appearance, functions and intelligence. Human-like robots, which for many years have been a science fiction, are increasingly becoming an engineering reality resulting from the many advances in biologically inspired technologies. These biomimetic technologies include artificial intelligence, artificial vision and hearing as well as artificial muscles, also known as electroactive polymers (EAP). Robots, such as the vacuum cleaner Rumba and the robotic lawnmower, that don't have human shape, are already finding growing use in homes worldwide. As opposed to other human-made machines and devices, this technology raises also various questions and concerns and they need to be addressed as the technology advances. These include the need to prevent accidents, deliberate harm, or their use in crime. In this paper the state-of-the-art of the ultimate goal of biomimetics, the development of humanlike robots, the potentials and the challenges are reviewed.

  1. Humanlike robots: the upcoming revolution in robotics

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2009-08-01

    Humans have always sought to imitate the human appearance, functions and intelligence. Human-like robots, which for many years have been a science fiction, are increasingly becoming an engineering reality resulting from the many advances in biologically inspired technologies. These biomimetic technologies include artificial intelligence, artificial vision and hearing as well as artificial muscles, also known as electroactive polymers (EAP). Robots, such as the vacuum cleaner Rumba and the robotic lawnmower, that don't have human shape, are already finding growing use in homes worldwide. As opposed to other human-made machines and devices, this technology raises also various questions and concerns and they need to be addressed as the technology advances. These include the need to prevent accidents, deliberate harm, or their use in crime. In this paper the state-of-the-art of the ultimate goal of biomimetics, the development of humanlike robots, the potentials and the challenges are reviewed.

  2. Development of wall ranging radiation inspection robot

    International Nuclear Information System (INIS)

    Lee, B. J.; Yoon, J. S.; Park, Y. S.; Hong, D. H.; Oh, S. C.; Jung, J. H.; Chae, K. S.

    1999-03-01

    With the aging of nation's nuclear facilities, the target of this project is to develop an under water wall ranging robotic vehicle which inspects the contamination level of the research reactor (TRIGA MARK III) as a preliminary process to dismantling. The developed vehicle is driven by five thrusters and consists of small sized control boards, and absolute position detector, and a radiation detector. Also, the algorithm for autonomous navigation is developed and its performance is tested through under water experiments. Also, the test result at the research reactor shows that the vehicle firmly attached the wall while measuring the contamination level of the wall

  3. Development of wall ranging radiation inspection robot

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B. J.; Yoon, J. S.; Park, Y. S.; Hong, D. H.; Oh, S. C.; Jung, J. H.; Chae, K. S

    1999-03-01

    With the aging of nation's nuclear facilities, the target of this project is to develop an under water wall ranging robotic vehicle which inspects the contamination level of the research reactor (TRIGA MARK III) as a preliminary process to dismantling. The developed vehicle is driven by five thrusters and consists of small sized control boards, and absolute position detector, and a radiation detector. Also, the algorithm for autonomous navigation is developed and its performance is tested through under water experiments. Also, the test result at the research reactor shows that the vehicle firmly attached the wall while measuring the contamination level of the wall.

  4. Inverse kinematic solution for near-simple robots and its application to robot calibration

    Science.gov (United States)

    Hayati, Samad A.; Roston, Gerald P.

    1986-01-01

    This paper provides an inverse kinematic solution for a class of robot manipulators called near-simple manipulators. The kinematics of these manipulators differ from those of simple-robots by small parameter variations. Although most robots are by design simple, in practice, due to manufacturing tolerances, every robot is near-simple. The method in this paper gives an approximate inverse kinematics solution for real time applications based on the nominal solution for these robots. The validity of the results are tested both by a simulation study and by applying the algorithm to a PUMA robot.

  5. Fish and robots swimming together: attraction towards the robot demands biomimetic locomotion.

    Science.gov (United States)

    Marras, Stefano; Porfiri, Maurizio

    2012-08-07

    The integration of biomimetic robots in a fish school may enable a better understanding of collective behaviour, offering a new experimental method to test group feedback in response to behavioural modulations of its 'engineered' member. Here, we analyse a robotic fish and individual golden shiners (Notemigonus crysoleucas) swimming together in a water tunnel at different flow velocities. We determine the positional preference of fish with respect to the robot, and we study the flow structure using a digital particle image velocimetry system. We find that biomimetic locomotion is a determinant of fish preference as fish are more attracted towards the robot when its tail is beating rather than when it is statically immersed in the water as a 'dummy'. At specific conditions, the fish hold station behind the robot, which may be due to the hydrodynamic advantage obtained by swimming in the robot's wake. This work makes a compelling case for the need of biomimetic locomotion in promoting robot-animal interactions and it strengthens the hypothesis that biomimetic robots can be used to study and modulate collective animal behaviour.

  6. Micro robot bible

    International Nuclear Information System (INIS)

    Yoon, Jin Yeong

    2000-08-01

    This book deals with micro robot, which tells of summary of robots like entertainment robots and definition of robots, introduction of micro mouse about history, composition and rules, summary of micro controller with its history, appearance and composition, introduction of stepping motor about types, structure, basic characteristics, and driving ways, summary of sensor section, power, understanding of 80C196KC micro controller, basic driving program searching a maze algorithm, smooth turn and making of tracer line.

  7. Micro robot bible

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jin Yeong

    2000-08-15

    This book deals with micro robot, which tells of summary of robots like entertainment robots and definition of robots, introduction of micro mouse about history, composition and rules, summary of micro controller with its history, appearance and composition, introduction of stepping motor about types, structure, basic characteristics, and driving ways, summary of sensor section, power, understanding of 80C196KC micro controller, basic driving program searching a maze algorithm, smooth turn and making of tracer line.

  8. Robots at Work

    OpenAIRE

    Graetz, Georg; Michaels, Guy

    2015-01-01

    Despite ubiquitous discussions of robots' potential impact, there is almost no systematic empirical evidence on their economic effects. In this paper we analyze for the first time the economic impact of industrial robots, using new data on a panel of industries in 17 countries from 1993-2007. We find that industrial robots increased both labor productivity and value added. Our panel identification is robust to numerous controls, and we find similar results instrumenting increased robot use wi...

  9. Effect of transcutaneous electrical stimulation treatment on lower urinary tract symptoms after class III radical hysterectomy in cervical cancer patients: study protocol for a multicentre, randomized controlled trial.

    Science.gov (United States)

    Sun, Xiu-Li; Wang, Hai-Bo; Wang, Zhi-Qi; Cao, Ting-Ting; Yang, Xin; Han, Jing-Song; Wu, Yang-Feng; Reilly, Kathleen H; Wang, Jian-Liu

    2017-06-15

    Class III radical hysterectomy (RH III)_plus pelvic lymphadenectomy is the standard surgery for early stage cervical cancer (CC) patients, the 5 year survival rate is about 90%, but pelvic floor disorders especially bladder dysfunction are common due to damaged vessels and nerve fibers following surgery. Transcutaneous electrical stimulation (TENS) treatment has been used to treat bladder disorders for many years, but its effect on cervical cancer patients, the best treatment time point and stimulated protocol, had never been assessed. The aim of this study is to investigate the efficacy of TENS treatment on lower urinary tract symptoms (LUTS) after RH III in CC patients. The study will be conducted as a clinical, multicentre, randomised controlled trial with balanced randomisation (1:1). The planned sample size is 208 participants (at 1:1 ratio, 104 subjects in each group). At 5-7 days after RH III, patients are screened according to operative and pathological findings. Enrolled participants are randomised into an intervention group (TENS plus conventional clinical care) or control group (conventional clinical care), with stratification by menopausal status (menopause vs. non-menopause) and surgical modality (laparoscopic RH or abdominal RH). Participants in both groups will be followed up at 14 days, 21 days, 28 days, 3 months, 6 months, 12 months, 18 months and 24 months after surgery. The primary endpoint is improvement rate of urination function which is defined as recovery (residual urine ≤50 ml) or improvement (residual urine 50-100 ml). Secondary endpoints include urodynamic parameter, urinary incontinence, anorectal function, pelvic function, quality of life (QOL), disease-free survival and adverse events. Primary endpoint analyses will be carried out by Cochran-Mantel-Haenszel tests taking into center effect. To our knowledge this is the first trial to investigate the effect of TENS treatment on bladder function recovery after RH III among

  10. To Err Is Robot: How Humans Assess and Act toward an Erroneous Social Robot

    Directory of Open Access Journals (Sweden)

    Nicole Mirnig

    2017-05-01

    Full Text Available We conducted a user study for which we purposefully programmed faulty behavior into a robot’s routine. It was our aim to explore if participants rate the faulty robot different from an error-free robot and which reactions people show in interaction with a faulty robot. The study was based on our previous research on robot errors where we detected typical error situations and the resulting social signals of our participants during social human–robot interaction. In contrast to our previous work, where we studied video material in which robot errors occurred unintentionally, in the herein reported user study, we purposefully elicited robot errors to further explore the human interaction partners’ social signals following a robot error. Our participants interacted with a human-like NAO, and the robot either performed faulty or free from error. First, the robot asked the participants a set of predefined questions and then it asked them to complete a couple of LEGO building tasks. After the interaction, we asked the participants to rate the robot’s anthropomorphism, likability, and perceived intelligence. We also interviewed the participants on their opinion about the interaction. Additionally, we video-coded the social signals the participants showed during their interaction with the robot as well as the answers they provided the robot with. Our results show that participants liked the faulty robot significantly better than the robot that interacted flawlessly. We did not find significant differences in people’s ratings of the robot’s anthropomorphism and perceived intelligence. The qualitative data confirmed the questionnaire results in showing that although the participants recognized the robot’s mistakes, they did not necessarily reject the erroneous robot. The annotations of the video data further showed that gaze shifts (e.g., from an object to the robot or vice versa and laughter are typical reactions to unexpected robot behavior

  11. ROILA : RObot Interaction LAnguage

    NARCIS (Netherlands)

    Mubin, O.

    2011-01-01

    The number of robots in our society is increasing rapidly. The number of service robots that interact with everyday people already outnumbers industrial robots. The easiest way to communicate with these service robots, such as Roomba or Nao, would be natural speech. However, the limitations

  12. The games radicals play : special issue on free radicals and radical ions

    OpenAIRE

    Walton, J.C.; Williams, F.

    2015-01-01

    Chemistry and Physics have aptly been described as “most excellent children of Intellect and Art” [1]. Both these “children” engage with many playthings, and molecules rank as one of their first favorites, especially radicals, which are amongst the most lively and exciting. Checking out radicals dancing to the music of entropy round their potential energy ballrooms is surely both entertaining and enlightening. Radicals’ old favorite convolutions are noteworthy, but the new styles, modes and a...

  13. Time resolved resonance Raman spectra of anilino radical and aniline radical cation

    International Nuclear Information System (INIS)

    Tripathi, G.N.R.; Schuler, R.H.

    1987-01-01

    We report, in this paper, submicrosecond time resolved resonance Raman spectra of anilino radical and its radical cation as observed in pulse radiolytic studies of the oxidation of aniline in aqueous solution. By excitation in resonance with the broad and weak electronic transition of anilino radical at 400 nm (ε--1250 M -1 cm -1 ) we have observed, for the first time, the vibrational features of this radical. The Wilson ν 8 /sub a/ ring stretching mode at 1560 cm -1 is most strongly resonance enhanced. The ν 7 /sub a/ CN stretching band at 1505 cm -1 , which is shifted to higher frequency by 231 cm -1 with respect to aniline, is also prominent. The frequency of this latter mode indicates that the CN bond in the radical has considerable double bond character. The Raman spectrum of aniline radical cation, excited in resonance with the --425 nm electronic absorption (ε--4000 M -1 cm -1 ), shows features which are similar to phenoxyl radical. Most of the observed frequencies of this radical in solution are in good agreement with vibrational energies determined by recent laser photoelectron spectroscopic studies in the vapor phase. The bands most strongly enhanced in the resonance Raman spectrum are, however, weak in the photoelectron spectrum. While the vibrational frequencies observed for anilino radical and its isoelectronic cation are quite similar, the resonance enhancement patterns are very different. In particular the ν 14 b 2 mode of anilino radical observed at 1324 cm -1 is highly resonance enhanced because of strong vibronic coupling between the 400 nm 2 A 2 -- 2 B 1 and the higher 2 B 1 -- 2 B 1 electronic transitions

  14. Evidence for robots.

    Science.gov (United States)

    Shenoy, Ravikiran; Nathwani, Dinesh

    2017-01-01

    Robots have been successfully used in commercial industry and have enabled humans to perform tasks which are repetitive, dangerous and requiring extreme force. Their role has evolved and now includes many aspects of surgery to improve safety and precision. Orthopaedic surgery is largely performed on bones which are rigid immobile structures which can easily be performed by robots with great precision. Robots have been designed for use in orthopaedic surgery including joint arthroplasty and spine surgery. Experimental studies have been published evaluating the role of robots in arthroscopy and trauma surgery. In this article, we will review the incorporation of robots in orthopaedic surgery looking into the evidence in their use. © The Authors, published by EDP Sciences, 2017.

  15. Scavenging capacity of strawberry tree (Arbutus unedo L.) leaves on free radicals.

    Science.gov (United States)

    Oliveira, Ivo; Coelho, Valentim; Baltasar, Raquel; Pereira, José Alberto; Baptista, Paula

    2009-07-01

    Despite strawberry tree (Arbutus unedo L.) leaves had a long use in traditional medicine due to its antiseptic, diuretic, astringent and depurative properties, the potential of their antioxidant activity are still lacking. Our study goals to assess the antioxidant and free radical scavenging potential of water, ethanol, methanol and diethyl ether extracts of A. unedo leaves. Total phenols content was achieved spectrophotometrically using Folin-Ciocalteau reagent with gallic acid as standard. Antioxidant activity was evaluated using three different methods: reducing power of iron (III)/ferricyanide complex assay, scavenging effect on DPPH (2,2-diphenyl-1-picrylhydrazyl) radicals and scavenging effect on superoxide radicals by using the PMS-NADH-nitroblue tetrazolium system. Ethanol extracts of A. unedo leaves were the highest in reducing power (IC(50) 232.7 microg/mL) and DPPH scavenging effect (IC(50) 63.2 microg/mL) followed by water extracts (with IC(50) of 287.7 and 73.7 microg/mL, respectively); whereas diethyl ether extracts were the lowest. In the scavenging on superoxide radical assay, methanol extracts obtained the best results (IC(50) 6.9 microg/mL). For all the methods tested the antioxidant activity was concentration dependent. In accordance with antioxidant activity, highest total phenols content were found in ethanol, followed by water, methanol and diethyl ether extract. The results indicated that A. unedo leaves are a potential source of natural antioxidants.

  16. Study of new compounds for their application on free radicals EPR dosimetry

    International Nuclear Information System (INIS)

    Condes N, C.S.

    1996-01-01

    L- α alanine is an amino acid which has been used for electron and γ ray dosimetric purposes, when crystallites of L-α alanine are irradiated with ionizing radiation free radicals are produced. The yield of free radicals produced by irradiation of alanine crystals can be evaluated by EPR spectrometry, however when L- α alanine crystals are irradiated with thermal neutrons the yield of the free radicals produced is very low and in consequence it's EPR-signal response is poor. In this work we mixed L-α alanine together with some lithium compounds such as LiF, LiBO 2 , LiOH and Li 2 CO 3 . In this way when we irradiate the respective mixture of alanine-lithium with thermal neutrons, the nuclear reactions 6 Li (n,α)T and 10 B (n, α) 7 Li can be produced with a high probability. As a consequence α particles and recoil atoms emerging from the nuclear reactions can impinge on alanine molecules, producing extra free radicals. From the alanine-lithium mixtures obtained, we made dosemeters (30 mm long., 3.9 mm diameter) which were irradiated in the thermal column of the TRIGA Mark III Nuclear Reactor with a flux of thermal neutrons of 5 x 10 7 n/ cm 2 s. Irradiations were made at different periods. Experimental evaluations indicate that the mixtures can be used for dosimetric purposes. (Author)

  17. Message Encryption in Robot Operating System: Collateral Effects of Hardening Mobile Robots

    Directory of Open Access Journals (Sweden)

    Francisco J. Rodríguez-Lera

    2018-03-01

    Full Text Available In human–robot interaction situations, robot sensors collect huge amounts of data from the environment in order to characterize the situation. Some of the gathered data ought to be treated as private, such as medical data (i.e., medication guidelines, personal, and safety information (i.e., images of children, home habits, alarm codes, etc.. However, most robotic software development frameworks are not designed for securely managing this information. This paper analyzes the scenario of hardening one of the most widely used robotic middlewares, Robot Operating System (ROS. The study investigates a robot’s performance when ciphering the messages interchanged between ROS nodes under the publish/subscribe paradigm. In particular, this research focuses on the nodes that manage cameras and LIDAR sensors, which are two of the most extended sensing solutions in mobile robotics, and analyzes the collateral effects on the robot’s achievement under different computing capabilities and encryption algorithms (3DES, AES, and Blowfish to robot performance. The findings present empirical evidence that simple encryption algorithms are lightweight enough to provide cyber-security even in low-powered robots when carefully designed and implemented. Nevertheless, these techniques come with a number of serious drawbacks regarding robot autonomy and performance if they are applied randomly. To avoid these issues, we define a taxonomy that links the type of ROS message, computational units, and the encryption methods. As a result, we present a model to select the optimal options for hardening a mobile robot using ROS.

  18. 1st Iberian Robotics Conference

    CERN Document Server

    Sanfeliu, Alberto; Ferre, Manuel; ROBOT2013; Advances in robotics

    2014-01-01

    This book contains the proceedings of the ROBOT 2013: FIRST IBERIAN ROBOTICS CONFERENCE and it can be said that included both state of the art and more practical presentations dealing with implementation problems, support technologies and future applications. A growing interest in Assistive Robotics, Agricultural Robotics, Field Robotics, Grasping and Dexterous Manipulation, Humanoid Robots, Intelligent Systems and Robotics, Marine Robotics, has been demonstrated by the very relevant number of contributions. Moreover, ROBOT2013 incorporates a special session on Legal and Ethical Aspects in Robotics that is becoming a topic of key relevance. This Conference was held in Madrid (28-29 November 2013), organised by the Sociedad Española para la Investigación y Desarrollo en Robótica (SEIDROB) and by the Centre for Automation and Robotics - CAR (Universidad Politécnica de Madrid (UPM) and Consejo Superior de Investigaciones Científicas (CSIC)), along with the co-operation of Grupo Temático de Robótica CEA-GT...

  19. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  20. Springer handbook of robotics

    CERN Document Server

    Khatib, Oussama

    2016-01-01

    The second edition of this handbook provides a state-of-the-art cover view on the various aspects in the rapidly developing field of robotics. Reaching for the human frontier, robotics is vigorously engaged in the growing challenges of new emerging domains. Interacting, exploring, and working with humans, the new generation of robots will increasingly touch people and their lives. The credible prospect of practical robots among humans is the result of the scientific endeavour of a half a century of robotic developments that established robotics as a modern scientific discipline. The ongoing vibrant expansion and strong growth of the field during the last decade has fueled this second edition of the Springer Handbook of Robotics. The first edition of the handbook soon became a landmark in robotics publishing and won the American Association of Publishers PROSE Award for Excellence in Physical Sciences & Mathematics as well as the organization’s Award for Engineering & Technology. The second edition o...

  1. Innovations in robotic surgery.

    Science.gov (United States)

    Gettman, Matthew; Rivera, Marcelino

    2016-05-01

    Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.

  2. Robotic-Assisted Minimally Invasive Surgery for Gynecologic and Urologic Oncology

    Science.gov (United States)

    2010-01-01

    increase the risk for cervical cancer are multiple sexual partners, early sexual activity, infection with the human papillomavirus, and cigarette smoking, whereas barrier-type of contraception as a risk factor decreases the risk of cervical cancer. Prostate cancer is ranked first in men in Canada in terms of the number of new cases among all male cancers (25,500 of 89,300 or 28.6%). The impact on men who develop prostate cancer is substantial given the potential for erectile dysfunction and urinary incontinence. Prostate cancer arises within the prostate gland, which resides in the male reproductive system and near the bladder. Radical retropubic prostatectomy is the gold standard treatment for localized prostate cancer. Prostate cancer affects men above 60 years of age. Other risk factors include a family history of prostate cancer, being of African descent, being obese, consuming a diet high in fat, physical inactivity, and working with cadium. The Da Vinci Surgical System The Da Vinci Surgical System is a robotic device. There are four main components to the system: 1) the surgeon’s console, where the surgeon sits and views a magnified three-dimensional image of the surgical field; 2) patient side-cart, which sits beside the patient and consists of three instrument arms and one endoscope arm; 3) detachable instruments (endowrist instruments and intuitive masters), which simulate fine motor human movements. The hand movements of the surgeon’s hands at the surgeon’s console are translated into smaller ones by the robotic device and are acted out by the attached instruments; 4) three-dimensional vision system: the camera unit or endoscope arm. The main advantages of use of the robotic device are: 1) the precision of the instrument and improved dexterity due to the use of “wristed” instruments; 2) three-dimensional imaging, with improved ability to locate blood vessels, nerves and tissues; 3) the surgeon’s console, which reduces fatigue accompanied with

  3. Faster-than-real-time robot simulation for plan development and robot safety

    International Nuclear Information System (INIS)

    Crane, C.D. III; Dalton, R.; Ogles, J.; Tulenko, J.S.; Zhou, X.

    1990-01-01

    The University of Florida, in cooperation with the Universities of Texas, Tennessee, and Michigan and Oak Ridge National Laboratory (ORNL), is developing an advanced robotic system for the US Department of Energy under the University Program for Robotics for Advanced Reactors. As part of this program, the University of Florida has been pursuing the development of a faster-than-real-time robotic simulation program for planning and control of mobile robotic operations to ensure the efficient and safe operation of mobile robots in nuclear power plants and other hazardous environments

  4. Soft-Material Robotics

    OpenAIRE

    Wang, L; Nurzaman, SG; Iida, Fumiya

    2017-01-01

    There has been a boost of research activities in robotics using soft materials in the past ten years. It is expected that the use and control of soft materials can help realize robotic systems that are safer, cheaper, and more adaptable than the level that the conventional rigid-material robots can achieve. Contrary to a number of existing review and position papers on soft-material robotics, which mostly present case studies and/or discuss trends and challenges, the review focuses on the fun...

  5. Design of a robotic device for assessment and rehabilitation of hand sensory function.

    Science.gov (United States)

    Lambercy, Olivier; Robles, Alejandro Juárez; Kim, Yeongmi; Gassert, Roger

    2011-01-01

    This paper presents the design and implementation of the Robotic Sensory Trainer, a robotic interface for assessment and therapy of hand sensory function. The device can provide three types of well controlled stimuli: (i) angular displacement at the metacarpophalangeal (MCP) joint using a remote-center-of-motion double-parallelogram structure, (ii) vibration stimuli at the fingertip, proximal phalange and palm, and (iii) pressure at the fingertip, while recording position, interaction force and feedback from the user over a touch screen. These stimuli offer a novel platform to investigate sensory perception in healthy subjects and patients with sensory impairments, with the potential to assess deficits and actively train detection of specific sensory cues in a standardized manner. A preliminary study with eight healthy subjects demonstrates the feasibility of using the Robotic Sensory Trainer to assess the sensory perception threshold in MCP angular position. An average just noticeable difference (JND) in the MCP joint angle of 2.46° (14.47%) was found, which is in agreement with previous perception studies. © 2011 IEEE

  6. AssistMe robot, an assistance robotic platform

    Directory of Open Access Journals (Sweden)

    A. I. Alexan

    2012-06-01

    Full Text Available This paper presents the design and implementation of a full size assistance robot. Its main purpose it to assist a person and eventually avoid a life threatening situation. Its implementation revolves around a chipKIT Arduino board that interconnects a robotic base controller with a 7 inch TABLET PC and various sensors. Due to the Android and Arduino combination, the robot can interact with the person and provide an easy development platform for future improvement and feature adding. The TABLET PC is Webcam, WIFI and Bluetooth enabled, offering a versatile platform that is able to process data and in the same time provide the user a friendly interface.

  7. Socially Impaired Robots: Human Social Disorders and Robots' Socio-Emotional Intelligence

    OpenAIRE

    Vitale, Jonathan; Williams, Mary-Anne; Johnston, Benjamin

    2016-01-01

    Social robots need intelligence in order to safely coexist and interact with humans. Robots without functional abilities in understanding others and unable to empathise might be a societal risk and they may lead to a society of socially impaired robots. In this work we provide a survey of three relevant human social disorders, namely autism, psychopathy and schizophrenia, as a means to gain a better understanding of social robots' future capability requirements. We provide evidence supporting...

  8. Educational Robotics as Mindtools

    Science.gov (United States)

    Mikropoulos, Tassos A.; Bellou, Ioanna

    2013-01-01

    Although there are many studies on the constructionist use of educational robotics, they have certain limitations. Some of them refer to robotics education, rather than educational robotics. Others follow a constructionist approach, but give emphasis only to design skills, creativity and collaboration. Some studies use robotics as an educational…

  9. Robot friendship: Can a robot be a friend?

    DEFF Research Database (Denmark)

    Emmeche, Claus

    2014-01-01

    Friendship is used here as a conceptual vehicle for framing questions about the distinctiveness of human cognition in relation to natural systems such as other animal species and to artificial systems such as robots. By exploring this very common form of a human interpersonal relationship......, the author indicates that even though it is difficult to say something generally true about friendship among humans, distinct forms of friendship as practiced and distinct notions of friendship have been investigated in the social and human sciences and in biology. A more general conceptualization...... of friendship as a triadic relation analogous to the sign relation is suggested. Based on this the author asks how one may conceive of robot-robot and robot-human friendships; and how an interdisciplinary perspective upon that relation can contribute to analyse levels of embodied cognition in natural...

  10. Multi-robot caravanning

    KAUST Repository

    Denny, Jory

    2013-11-01

    We study multi-robot caravanning, which is loosely defined as the problem of a heterogeneous team of robots visiting specific areas of an environment (waypoints) as a group. After formally defining this problem, we propose a novel solution that requires minimal communication and scales with the number of waypoints and robots. Our approach restricts explicit communication and coordination to occur only when robots reach waypoints, and relies on implicit coordination when moving between a given pair of waypoints. At the heart of our algorithm is the use of leader election to efficiently exploit the unique environmental knowledge available to each robot in order to plan paths for the group, which makes it general enough to work with robots that have heterogeneous representations of the environment. We implement our approach both in simulation and on a physical platform, and characterize the performance of the approach under various scenarios. We demonstrate that our approach can successfully be used to combine the planning capabilities of different agents. © 2013 IEEE.

  11. Self-Organizing Robots

    CERN Document Server

    Murata, Satoshi

    2012-01-01

    It is man’s ongoing hope that a machine could somehow adapt to its environment by reorganizing itself. This is what the notion of self-organizing robots is based on. The theme of this book is to examine the feasibility of creating such robots within the limitations of current mechanical engineering. The topics comprise the following aspects of such a pursuit: the philosophy of design of self-organizing mechanical systems; self-organization in biological systems; the history of self-organizing mechanical systems; a case study of a self-assembling/self-repairing system as an autonomous distributed system; a self-organizing robot that can create its own shape and robotic motion; implementation and instrumentation of self-organizing robots; and the future of self-organizing robots. All topics are illustrated with many up-to-date examples, including those from the authors’ own work. The book does not require advanced knowledge of mathematics to be understood, and will be of great benefit to students in the rob...

  12. Human-robot interaction tests on a novel robot for gait assistance.

    Science.gov (United States)

    Tagliamonte, Nevio Luigi; Sergi, Fabrizio; Carpino, Giorgio; Accoto, Dino; Guglielmelli, Eugenio

    2013-06-01

    This paper presents tests on a treadmill-based non-anthropomorphic wearable robot assisting hip and knee flexion/extension movements using compliant actuation. Validation experiments were performed on the actuators and on the robot, with specific focus on the evaluation of intrinsic backdrivability and of assistance capability. Tests on a young healthy subject were conducted. In the case of robot completely unpowered, maximum backdriving torques were found to be in the order of 10 Nm due to the robot design features (reduced swinging masses; low intrinsic mechanical impedance and high-efficiency reduction gears for the actuators). Assistance tests demonstrated that the robot can deliver torques attracting the subject towards a predicted kinematic status.

  13. Intramolecular transformation of thiyl radicals to α-aminoalkyl radicals: 'ab initio' calculations on homocystein

    International Nuclear Information System (INIS)

    Chhun, S.; Berges, J.; Bleton, V.; Abedinzadeh, Z.

    2000-01-01

    One-electron oxidation of thiols by oxidizing radicals leads to the formation of thiyl radical and carbon-centered radicals. It has been shown experimentally that in the absence of oxygen, the thiyl radicals derived from certain thiols of biological interest such as glutathion, cysteine and homocysteine decay rapidly by intramolecular rearrangement reactions into the carbon-centered radical. In the present work we have investigated theoretically the structure and the stability of thiyl and carbon-centered radicals of homocysteine in order to check the possibility of this rearrangement. (author)

  14. Pose Estimation and Adaptive Robot Behaviour for Human-Robot Interaction

    DEFF Research Database (Denmark)

    Svenstrup, Mikael; Hansen, Søren Tranberg; Andersen, Hans Jørgen

    2009-01-01

    Abstract—This paper introduces a new method to determine a person’s pose based on laser range measurements. Such estimates are typically a prerequisite for any human-aware robot navigation, which is the basis for effective and timeextended interaction between a mobile robot and a human. The robot......’s pose. The resulting pose estimates are used to identify humans who wish to be approached and interacted with. The interaction motion of the robot is based on adaptive potential functions centered around the person that respect the persons social spaces. The method is tested in experiments...

  15. From sex robots to love robots: is mutual love with a robot possible?

    NARCIS (Netherlands)

    Nyholm, S.R.; Frank, L.E.; Danaher, J.; McArthur, N.

    2017-01-01

    Some critics of sex-robots worry that their use might spread objectifying attitudes about sex, and common sense places a higher value on sex within love-relationships than on casual sex. If there could be mutual love between humans and sex-robots, this could help to ease the worries about

  16. The relation between people's attitudes and anxiety towards robots in human-robot interaction

    NARCIS (Netherlands)

    de Graaf, M.M.A.; Ben Allouch, Soumaya

    2013-01-01

    This paper examines the relation between an interaction with a robot and peoples’ attitudes and emotion towards robots. In our study, participants have had an acquaintance talk with a social robot and both their general attitude and anxiety towards social robots were measured before and after the

  17. Effect of robotic manipulation on unidirectional barbed suture integrity: evaluation of tensile strength and sliding force.

    Science.gov (United States)

    Kaushik, Dharam; Clay, Kevin; Hossain, S G M; Park, Eugene; Nelson, Carl A; LaGrange, Chad A

    2012-06-01

    One of the more challenging portions of robot-assisted radical prostatectomy (RARP) is the urethrovesical anastomosis. Because of this, a unidirectional absorbable barbed suture (V-Loc(™)) has been used to complete the anastomosis with better efficiency and less tension. The effect of robotic needle driver manipulation on barbed suture is unknown. Therefore, the aim of this study is to determine whether robotic manipulation decreases the tensile strength and peak sliding force of V-Loc barbed suture. Fifty-six V-Loc sutures were compared with 56 Maxon sutures. All sutures were 3-0 caliber. Half of the sutures in each group were manipulated with a da Vinci(®) robot large needle driver five times over a 5 cm length of suture. The other half was not manipulated. Breaking force was determined by placing sutures in a Bose ElectroForce load testing device. For sliding force testing, 28 V-Loc sutures were manipulated in the same fashion and compared with 28 nonmanipulated V-Loc sutures. Peak force needed to make the suture slip backward in porcine small intestine was determined to be the sliding force. Scanning electron microscopy of the barbs before and after robotic manipulation was also performed. The mean difference in breaking forces for manipulated vs nonmanipulated Maxon sutures was 4.52 N (P=0.004). The mean difference in breaking forces for manipulated vs nonmanipulated V-Loc sutures was 1.30 N (P=0.046). The manipulated V-Loc group demonstrated a lower peak sliding force compared with the nonmanipulated group (0.76 vs 0.88 N, P=0.199). Electron microscopy revealed minor structural damage to the barbs and suture. Tensile strength and peak sliding force of V-Loc suture is decreased by robotic manipulation. This is likely because of structural damage to the suture and barbs. This structural damage, however, is likely not clinically significant.

  18. Free radical transfer in polymers

    International Nuclear Information System (INIS)

    Sonntag, C. von; Bothe, E.; Ulanski, P.

    1998-01-01

    For the present study of free-radical transfer in polymers pulse radiolysis and product studies have been carried out in aqueous solutions using thus far only the water-soluble polymers polyacrylic acid, polymethacrylic acid and polyvinyl alcohol. When OH radicals, generated in the radiolysis of N 2 O-saturated aqueous solutions, react with polymers the lifetime of the polymer radical thus created very much depends on the number of radicals per polymer chain. When there are a large number of radicals per chain their bimolecular decay may be faster than the corresponding (diffusion controlled) decay of monomeric radicals, but when the macromolecule contains only few or even just one radical their lifetime is considerably prolonged. Highly charged polymers such as polyacrylic acid at high pH attain a rod-like conformation which again favors a long lifetime of the radicals. Under such conditions, radical transfer reactions can occur. For example, in polyacrylic acid OH radicals generate two kinds of radicals side by side. The radical in β-position to the carboxylate group converts into the thermodynamically more stable α-radicals by an H-transfer reaction as can be followed by spectrophotometry. Besides radical transfer reactions β-fragmentation reactions occur causing chain scission. Such reactions can be followed in a pulse radiolysis experiment by conductometry, because counter ions are released upon chain scission. Such a process is especially effective in the case of polymethacrylic acid, where it results in a chain depolymerization. An intramolecular H-abstraction is also observed in the γ-radiolysis of polyacrylic acid with the corresponding peroxyl radicals. This causes a chain reaction to occur. The resulting hydroperoxides are unstable and decarboxylate given rise to acetylacetone-like products. In polyvinyl alcohol the peroxyl radicals in α-position to the alcohol function undergo HO 2 -elimination. This prevents a scission of the polymer chain in the

  19. Robotic hand project

    OpenAIRE

    Karaçizmeli, Cengiz; Çakır, Gökçe; Tükel, Dilek

    2014-01-01

    In this work, the mechatronic based robotic hand is controlled by the position data taken from the glove which has flex sensors mounted to capture finger bending of the human hand. The angular movement of human hand’s fingers are perceived and processed by a microcontroller, and the robotic hand is controlled by actuating servo motors. It has seen that robotic hand can simulate the movement of the human hand that put on the glove, during tests have done. This robotic hand can be used not only...

  20. PEAR: Prototyping Expressive Animated Robots - A framework for social robot prototyping

    OpenAIRE

    Balit , Etienne; Vaufreydaz , Dominique; Reignier , Patrick

    2018-01-01

    International audience; Social robots are transitioning from lab experiments to commercial products, creating new needs for proto-typing and design tools. In this paper, we present a framework to facilitate the prototyping of expressive animated robots. For this, we start by reviewing the design of existing social robots in order to define a set of basic components of social robots. We then show how to extend an existing 3D animation software to enable the animation of these components. By co...

  1. Developing a successful robotics program.

    Science.gov (United States)

    Luthringer, Tyler; Aleksic, Ilija; Caire, Arthur; Albala, David M

    2012-01-01

    Advancements in the robotic surgical technology have revolutionized the standard of care for many surgical procedures. The purpose of this review is to evaluate the important considerations in developing a new robotics program at a given healthcare institution. Patients' interest in robotic-assisted surgery has and continues to grow because of improved outcomes and decreased periods of hospitalization. Resulting market forces have created a solid foundation for the implementation of robotic surgery into surgical practice. Given proper surgeon experience and an efficient system, robotic-assisted procedures have been cost comparable to open surgical alternatives. Surgeon training and experience is closely linked to the efficiency of a new robotics program. Formally trained robotic surgeons have better patient outcomes and shorter operative times. Training in robotics has shown no negative impact on patient outcomes or mentor learning curves. Individual economic factors of local healthcare settings must be evaluated when planning for a new robotics program. The high cost of the robotic surgical platform is best offset with a large surgical volume. A mature, experienced surgeon is integral to the success of a new robotics program.

  2. Ergonomic deficits in robotic gynecologic oncology surgery: a need for intervention.

    Science.gov (United States)

    Craven, Renatta; Franasiak, Jason; Mosaly, Prithima; Gehrig, Paola A

    2013-01-01

    To evaluate surgeon strain using validated ergonomic assessment tools. Observational study (Canadian Task Force classification III). Academic medical center. Robotic surgeons performing gynecologic oncology surgical procedures. Videotape footage of surgeons performing robotic gynecologic oncology procedures was obtained. A human factors engineer experienced with health care ergonomics analyzed the video recordings and performed ergonomic evaluations of the surgeons. An initial evaluation was conducted using the Rapid Upper Limb Assessment (RULA) survey, an ergonomic assessment and prioritization method for determining posture, force, and frequency concerns with focus on the upper limbs. A more detailed analysis followed using the Strain Index (SI) method, which uses multiplicative interactions to identify jobs that are potentially hazardous. Seventeen hours of video recordings were analyzed, and descriptive data based on RULA/SI analysis were collected. Ergonomic evaluation of surgeon activity resulted in a mean RULA score of 6.46 (maximum possible RULA score, 7), indicating a need for further investigation. The mean SI grand score was 24.34. SI scores >10 suggest a potential for hazard to the operator. Thus, the current use of the surgical robot is potentially dangerous with regards to ergonomic positioning and should be modified. At a high-volume robotics center, there are ergonomics deficits that are hazardous to gynecologic surgeons and suggest the need for modification and intervention. A training strategy must be developed to address these ergonomic issues and knowledge deficiencies. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  3. Ascorbyl radical disproportionation in reverse micellar systems

    Science.gov (United States)

    Gębicki, J. L.; Szymańska-Owczarek, M.; Pacholczyk-Sienicka, B.; Jankowski, S.

    2018-04-01

    Ascorbyl radical was generated by the pulse radiolysis method and observed with the fast kinetic spectrophotometry within reverse micelles stabilized by AOT in n-heptane or by Igepal CO-520 in cyclohexane at different water to surfactant molar ratio, w0. Rate constants for the disproportionation of the ascorbyl radicals were smaller than those for intermicellar exchange for both type of reverse micelles and slower than those in homogeneous aqueous solutions. However, they increased with increasing w0 for AOT/n-heptane system, while they decreased for Igepal CO-520 system. The absorption spectra of ascorbic acid AOT/n-heptane reverse micellar system showed that the "pH" sensed by this molecule is lower than that in respective homogeneous aqueous solutions. The obtained results were rationalized taking into account three main factors (i) preferential location of ascorbic acid molecules in the interfacial region of the both types of reverse micelles; (ii) postulate that the pH of the interface is lower than that of the water pool of reverse micelles and (iii) different structure of the interface of the reverse micelles made by AOT in n-heptane and those formed by Igepal CO-520 I cyclohexane. Some possible consequences of these findings are discussed.

  4. Communication of Robot Status to Improve Human-Robot Collaboration

    Data.gov (United States)

    National Aeronautics and Space Administration — Future space exploration will require humans and robots to collaborate to perform all the necessary tasks. Current robots mostly operate separately from humans due...

  5. Making Humanoid Robots More Acceptable Based on the Study of Robot Characters in Animation

    Directory of Open Access Journals (Sweden)

    Fatemeh Maleki

    2015-03-01

    Full Text Available In this paper we take an approach in Humanoid Robots are not considered as robots who resembles human beings in a realistic way of appearance and act but as robots who act and react like human that make them more believable by people. Regarding this approach we will study robot characters in animation movies and discuss what makes some of them to be accepted just like a moving body and what makes some other robot characters to be believable as a living human. The goal of this paper is to create a rule set that describes friendly, socially acceptable, kind, cute... robots and in this study we will review example robots in popular animated movies. The extracted rules and features can be used for making real robots more acceptable.

  6. Robotics in medicine

    Science.gov (United States)

    Kuznetsov, D. N.; Syryamkin, V. I.

    2015-11-01

    Modern technologies play a very important role in our lives. It is hard to imagine how people can get along without personal computers, and companies - without powerful computer centers. Nowadays, many devices make modern medicine more effective. Medicine is developing constantly, so introduction of robots in this sector is a very promising activity. Advances in technology have influenced medicine greatly. Robotic surgery is now actively developing worldwide. Scientists have been carrying out research and practical attempts to create robotic surgeons for more than 20 years, since the mid-80s of the last century. Robotic assistants play an important role in modern medicine. This industry is new enough and is at the early stage of development; despite this, some developments already have worldwide application; they function successfully and bring invaluable help to employees of medical institutions. Today, doctors can perform operations that seemed impossible a few years ago. Such progress in medicine is due to many factors. First, modern operating rooms are equipped with up-to-date equipment, allowing doctors to make operations more accurately and with less risk to the patient. Second, technology has enabled to improve the quality of doctors' training. Various types of robots exist now: assistants, military robots, space, household and medical, of course. Further, we should make a detailed analysis of existing types of robots and their application. The purpose of the article is to illustrate the most popular types of robots used in medicine.

  7. Inventing Japan's 'robotics culture': the repeated assembly of science, technology, and culture in social robotics.

    Science.gov (United States)

    Sabanović, Selma

    2014-06-01

    Using interviews, participant observation, and published documents, this article analyzes the co-construction of robotics and culture in Japan through the technical discourse and practices of robotics researchers. Three cases from current robotics research--the seal-like robot PARO, the Humanoid Robotics Project HRP-2 humanoid, and 'kansei robotics' - show the different ways in which scientists invoke culture to provide epistemological grounding and possibilities for social acceptance of their work. These examples show how the production and consumption of social robotic technologies are associated with traditional crafts and values, how roboticists negotiate among social, technical, and cultural constraints while designing robots, and how humans and robots are constructed as cultural subjects in social robotics discourse. The conceptual focus is on the repeated assembly of cultural models of social behavior, organization, cognition, and technology through roboticists' narratives about the development of advanced robotic technologies. This article provides a picture of robotics as the dynamic construction of technology and culture and concludes with a discussion of the limits and possibilities of this vision in promoting a culturally situated understanding of technology and a multicultural view of science.

  8. German robots: The impact of industrial robots on workers

    OpenAIRE

    Dauth, Wolfgang; Findeisen, Sebastian; Südekum, Jens; Wößner, Nicole

    2017-01-01

    We study the impact of rising robot exposure on the careers of individual manufacturing workers, and the equilibrium impact across industries and local labor markets in Germany. We find no evidence that robots cause total job losses, but they do affect the composition of aggregate employment. Every robot destroys two manufacturing jobs. This accounts for almost 23 percent of the overall decline of manufacturing employment in Germany over the period 1994-2014, roughly 275,000 jobs. But this lo...

  9. Autonomous military robotics

    CERN Document Server

    Nath, Vishnu

    2014-01-01

    This SpringerBrief reveals the latest techniques in computer vision and machine learning on robots that are designed as accurate and efficient military snipers. Militaries around the world are investigating this technology to simplify the time, cost and safety measures necessary for training human snipers. These robots are developed by combining crucial aspects of computer science research areas including image processing, robotic kinematics and learning algorithms. The authors explain how a new humanoid robot, the iCub, uses high-speed cameras and computer vision algorithms to track the objec

  10. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  11. Toward cognitive robotics

    Science.gov (United States)

    Laird, John E.

    2009-05-01

    Our long-term goal is to develop autonomous robotic systems that have the cognitive abilities of humans, including communication, coordination, adapting to novel situations, and learning through experience. Our approach rests on the recent integration of the Soar cognitive architecture with both virtual and physical robotic systems. Soar has been used to develop a wide variety of knowledge-rich agents for complex virtual environments, including distributed training environments and interactive computer games. For development and testing in robotic virtual environments, Soar interfaces to a variety of robotic simulators and a simple mobile robot. We have recently made significant extensions to Soar that add new memories and new non-symbolic reasoning to Soar's original symbolic processing, which should significantly improve Soar abilities for control of robots. These extensions include episodic memory, semantic memory, reinforcement learning, and mental imagery. Episodic memory and semantic memory support the learning and recalling of prior events and situations as well as facts about the world. Reinforcement learning provides the ability of the system to tune its procedural knowledge - knowledge about how to do things. Mental imagery supports the use of diagrammatic and visual representations that are critical to support spatial reasoning. We speculate on the future of unmanned systems and the need for cognitive robotics to support dynamic instruction and taskability.

  12. Robot-Assisted Thoracoscopic Surgery versus Video-Assisted Thoracoscopic Surgery for Lung Lobectomy: Can a Robotic Approach Improve Short-Term Outcomes and Operative Safety?

    Science.gov (United States)

    Mahieu, Julien; Rinieri, Philippe; Bubenheim, Michael; Calenda, Emile; Melki, Jean; Peillon, Christophe; Baste, Jean-Marc

    2016-06-01

    Background Minimally invasive surgery has been recently recommended for treatment of early-stage non-small cell lung cancer. Despite the recent increase of robotic surgery, the place and potential advantages of the robot in thoracic surgery has not been well defined until now. Methods We reviewed our prospective database for retrospective comparison of our first 28 video-assisted thoracoscopic surgery lobectomies (V group) and our first 28 robotic lobectomies (R group). Results No significant difference was shown in median operative time between the two groups (185 vs. 190 minutes, p = 0.56). Median preincision time was significantly longer in the R group (80 vs. 60 minutes, P < 0.0001). The rate of emergency conversion for uncontrolled bleeding was lower in the R group (one vs. four). Median length of stay was comparable (6 days in the R group vs. 7 days in the V group, p = 0.4) with no significant difference in the rate of postoperative complications (eight Grade I in both groups, four Grade III or IV in the V group vs. six in the R group, according to the Clavien-Dindo classification, p = 0.93). No postoperative cardiac morbidity was observed in the R group. Median drainage time was similar (5 days, p = 0.78), with a rate of prolonged air leak slightly higher in the R group (25 vs. 17.8%, p = 0.74). Conclusion Perioperative outcomes are similar even in the learning period but robotic approach seems to offer more operative safety with fewer conversions for uncontrolled bleeding. Georg Thieme Verlag KG Stuttgart · New York.

  13. Conceptions of health service robots

    DEFF Research Database (Denmark)

    Lystbæk, Christian Tang

    2015-01-01

    Technology developments create rich opportunities for health service providers to introduce service robots in health care. While the potential benefits of applying robots in health care are extensive, the research into the conceptions of health service robot and its importance for the uptake...... of robotics technology in health care is limited. This article develops a model of the basic conceptions of health service robots that can be used to understand different assumptions and values attached to health care technology in general and health service robots in particular. The article takes...... a discursive approach in order to develop a conceptual framework for understanding the social values of health service robots. First a discursive approach is proposed to develop a typology of conceptions of health service robots. Second, a model identifying four basic conceptions of health service robots...

  14. Continuum limbed robots for locomotion

    Science.gov (United States)

    Mutlu, Alper

    This thesis focuses on continuum robots based on pneumatic muscle technology. We introduce a novel approach to use these muscles as limbs of lightweight legged robots. The flexibility of the continuum legs of these robots offers the potential to perform some duties that are not possible with classical rigid-link robots. Potential applications are as space robots in low gravity, and as cave explorer robots. The thesis covers the fabrication process of continuum pneumatic muscles and limbs. It also provides some new experimental data on this technology. Afterwards, the designs of two different novel continuum robots - one tripod, one quadruped - are introduced. Experimental data from tests using the robots is provided. The experimental results are the first published example of locomotion with tripod and quadruped continuum legged robots. Finally, discussion of the results and how far this technology can go forward is presented.

  15. Soft computing in advanced robotics

    CERN Document Server

    Kobayashi, Ichiro; Kim, Euntai

    2014-01-01

    Intelligent system and robotics are inevitably bound up; intelligent robots makes embodiment of system integration by using the intelligent systems. We can figure out that intelligent systems are to cell units, while intelligent robots are to body components. The two technologies have been synchronized in progress. Making leverage of the robotics and intelligent systems, applications cover boundlessly the range from our daily life to space station; manufacturing, healthcare, environment, energy, education, personal assistance, logistics. This book aims at presenting the research results in relevance with intelligent robotics technology. We propose to researchers and practitioners some methods to advance the intelligent systems and apply them to advanced robotics technology. This book consists of 10 contributions that feature mobile robots, robot emotion, electric power steering, multi-agent, fuzzy visual navigation, adaptive network-based fuzzy inference system, swarm EKF localization and inspection robot. Th...

  16. Robotics and remote systems applications

    International Nuclear Information System (INIS)

    Rabold, D.E.

    1996-01-01

    This article is a review of numerous remote inspection techniques in use at the Savannah River (and other) facilities. These include: (1) reactor tank inspection robot, (2) californium waste removal robot, (3) fuel rod lubrication robot, (4) cesium source manipulation robot, (5) tank 13 survey and decontamination robots, (6) hot gang valve corridor decontamination and junction box removal robots, (7) lead removal from deionizer vessels robot, (8) HB line cleanup robot, (9) remote operation of a front end loader at WIPP, (10) remote overhead video extendible robot, (11) semi-intelligent mobile observing navigator, (12) remote camera systems in the SRS canyons, (13) cameras and borescope for the DWPF, (14) Hanford waste tank camera system, (15) in-tank precipitation camera system, (16) F-area retention basin pipe crawler, (17) waste tank wall crawler and annulus camera, (18) duct inspection, and (19) deionizer resin sampling

  17. Situation Assessment for Mobile Robots

    DEFF Research Database (Denmark)

    Beck, Anders Billesø

    Mobile robots have become a mature technology. The first cable guided logistics robots were introduced in the industry almost 60 years ago. In this time the market for mobile robots in industry has only experienced a very modest growth and only 2.100 systems were sold worldwide in 2011. In recent...... years, many other domains have adopted the mobile robots, such as logistics robots at hospitals and the vacuum robots in our homes. However, considering the achievements in research the last 15 years within perception and operation in natural environments together with the reductions of costs in modern...... sensor systems, the growth potential for mobile robot applications are enormous. Many new technological components are available to move the limits of commercial mobile robot applications, but a key hindrance is reliability. Natural environments are complex and dynamic, and thus the risk of robots...

  18. Radical Trachelectomy for Early-Stage Cervical Cancer: A Survey of the Society of Gynecologic Oncology and Gynecologic Oncology Fellows-in-Training.

    Science.gov (United States)

    Churchill, Sara J; Armbruster, Shannon; Schmeler, Kathleen M; Frumovitz, Michael; Greer, Marilyn; Garcia, Jaime; Redworth, Glenda; Ramirez, Pedro T

    2015-05-01

    The aim of this study was to survey gynecologic oncologists and fellows-in-training regarding the role of radical trachelectomy (RT) and conservative surgery in patients with early-stage cervical cancer. From June 2012 to September 2012, the Society of Gynecologic Oncology member practitioners (n = 1353) and gynecologic oncology fellows (n = 156) were sent group-specific surveys investigating current practice, training, and the future of RT for early-stage cervical cancer management. Twenty-two percent of practitioners (n = 303) and 24.4% of fellows (n = 38) completed the surveys. Of the practitioners, 50% (n = 148) report performing RT, 98% (n = 269) support RT as treatment for squamous carcinoma, and 71% (n = 195) confirm the use of RT for adenocarcinoma. Most practitioners offer RT treatment for stages IA2 to IB1 smaller than 2 cm (n = 209, 76.8%) regardless of grade (77.7%) or lymph vascular space invasion (n = 211, 79.3%). Only 8% (n = 23) of practitioners feel that RT is appropriate for stage IBI larger than 2 cm. Respectively, both practitioners and fellows most frequently perform robotic-assisted (47.0%, n = 101 and 59.1%, n = 13) and abdominal (40.5%, n = 87 and 68.2%, n = 15) RT approaches. After training, fellows project the use of robotic-assisted (71%, n = 22) or abdominal methods (58.1%, n = 18). Overall, 75% (n = 227) of practitioners and 60% (n = 23) of fellows speculate that over the next 5 years, less radical procedures will be used to manage early-stage cervical cancer. Our findings suggest that practitioners and fellows believe RT remains an option for early-stage cervical cancer patients. However, a significant proportion of all respondents believe that less radical surgery may be a future consideration for patients with low-risk early-stage cervical cancer.

  19. Fundamentals of soft robot locomotion

    OpenAIRE

    Calisti, M.; Picardi, G.; Laschi, C.

    2017-01-01

    Soft robotics and its related technologies enable robot abilities in several robotics domains including, but not exclusively related to, manipulation, manufacturing, human���robot interaction and locomotion. Although field applications have emerged for soft manipulation and human���robot interaction, mobile soft robots appear to remain in the research stage, involving the somehow conflictual goals of having a deformable body and exerting forces on the environment to achieve locomotion. This p...

  20. Robotic therapy provides a stimulus for upper limb motor recovery after stroke that is complementary to and distinct from conventional therapy.

    Science.gov (United States)

    Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J; Lum, Peter S

    2014-05-01

    Individuals with chronic stroke often have long-lasting upper extremity impairments that impede function during activities of daily living. Rehabilitation robotics have shown promise in improving arm function, but current systems do not allow realistic training of activities of daily living. We have incorporated the ARMin III and HandSOME device into a novel robotic therapy modality that provides functional training of reach and grasp tasks. To compare the effects of equal doses of robotic and conventional therapy in individuals with chronic stroke. Subjects were randomized to 12 hours of robotic or conventional therapy and then crossed over to the other therapy type after a 1-month washout period. Twelve moderate to severely impaired individuals with chronic stroke were enrolled, and 10 completed the study. Across the 3-month study period, subjects showed significant improvements in the Fugl-Meyer (P = .013) and Box and Blocks tests (P = .028). The robotic intervention produced significantly greater improvements in the Action Research Arm Test than conventional therapy (P = .033). Gains in the Box and Blocks test from conventional therapy were larger than from robotic therapy in subjects who received conventional therapy after robotic therapy (P = .044). Data suggest that robotic therapy can elicit improvements in arm function that are distinct from conventional therapy and supplements conventional methods to improve outcomes. Results from this pilot study should be confirmed in a larger study.

  1. Open Issues in Evolutionary Robotics.

    Science.gov (United States)

    Silva, Fernando; Duarte, Miguel; Correia, Luís; Oliveira, Sancho Moura; Christensen, Anders Lyhne

    2016-01-01

    One of the long-term goals in evolutionary robotics is to be able to automatically synthesize controllers for real autonomous robots based only on a task specification. While a number of studies have shown the applicability of evolutionary robotics techniques for the synthesis of behavioral control, researchers have consistently been faced with a number of issues preventing the widespread adoption of evolutionary robotics for engineering purposes. In this article, we review and discuss the open issues in evolutionary robotics. First, we analyze the benefits and challenges of simulation-based evolution and subsequent deployment of controllers versus evolution on real robotic hardware. Second, we discuss specific evolutionary computation issues that have plagued evolutionary robotics: (1) the bootstrap problem, (2) deception, and (3) the role of genomic encoding and genotype-phenotype mapping in the evolution of controllers for complex tasks. Finally, we address the absence of standard research practices in the field. We also discuss promising avenues of research. Our underlying motivation is the reduction of the current gap between evolutionary robotics and mainstream robotics, and the establishment of evolutionary robotics as a canonical approach for the engineering of autonomous robots.

  2. Mergeable nervous systems for robots.

    Science.gov (United States)

    Mathews, Nithin; Christensen, Anders Lyhne; O'Grady, Rehan; Mondada, Francesco; Dorigo, Marco

    2017-09-12

    Robots have the potential to display a higher degree of lifetime morphological adaptation than natural organisms. By adopting a modular approach, robots with different capabilities, shapes, and sizes could, in theory, construct and reconfigure themselves as required. However, current modular robots have only been able to display a limited range of hardwired behaviors because they rely solely on distributed control. Here, we present robots whose bodies and control systems can merge to form entirely new robots that retain full sensorimotor control. Our control paradigm enables robots to exhibit properties that go beyond those of any existing machine or of any biological organism: the robots we present can merge to form larger bodies with a single centralized controller, split into separate bodies with independent controllers, and self-heal by removing or replacing malfunctioning body parts. This work takes us closer to robots that can autonomously change their size, form and function.Robots that can self-assemble into different morphologies are desired to perform tasks that require different physical capabilities. Mathews et al. design robots whose bodies and control systems can merge and split to form new robots that retain full sensorimotor control and act as a single entity.

  3. Evolving self-assembly in autonomous homogeneous robots: experiments with two physical robots.

    Science.gov (United States)

    Ampatzis, Christos; Tuci, Elio; Trianni, Vito; Christensen, Anders Lyhne; Dorigo, Marco

    2009-01-01

    This research work illustrates an approach to the design of controllers for self-assembling robots in which the self-assembly is initiated and regulated by perceptual cues that are brought forth by the physical robots through their dynamical interactions. More specifically, we present a homogeneous control system that can achieve assembly between two modules (two fully autonomous robots) of a mobile self-reconfigurable system without a priori introduced behavioral or morphological heterogeneities. The controllers are dynamic neural networks evolved in simulation that directly control all the actuators of the two robots. The neurocontrollers cause the dynamic specialization of the robots by allocating roles between them based solely on their interaction. We show that the best evolved controller proves to be successful when tested on a real hardware platform, the swarm-bot. The performance achieved is similar to the one achieved by existing modular or behavior-based approaches, also due to the effect of an emergent recovery mechanism that was neither explicitly rewarded by the fitness function, nor observed during the evolutionary simulation. Our results suggest that direct access to the orientations or intentions of the other agents is not a necessary condition for robot coordination: Our robots coordinate without direct or explicit communication, contrary to what is assumed by most research works in collective robotics. This work also contributes to strengthening the evidence that evolutionary robotics is a design methodology that can tackle real-world tasks demanding fine sensory-motor coordination.

  4. [Robotics in pediatric surgery].

    Science.gov (United States)

    Camps, J I

    2011-10-01

    Despite the extensive use of robotics in the adult population, the use of robotics in pediatrics has not been well accepted. There is still a lack of awareness from pediatric surgeons on how to use the robotic equipment, its advantages and indications. Benefit is still controversial. Dexterity and better visualization of the surgical field are one of the strong values. Conversely, cost and a lack of small instruments prevent the use of robotics in the smaller patients. The aim of this manuscript is to present the controversies about the use of robotics in pediatric surgery.

  5. Toward a framework for levels of robot autonomy in human-robot interaction.

    Science.gov (United States)

    Beer, Jenay M; Fisk, Arthur D; Rogers, Wendy A

    2014-07-01

    A critical construct related to human-robot interaction (HRI) is autonomy, which varies widely across robot platforms. Levels of robot autonomy (LORA), ranging from teleoperation to fully autonomous systems, influence the way in which humans and robots may interact with one another. Thus, there is a need to understand HRI by identifying variables that influence - and are influenced by - robot autonomy. Our overarching goal is to develop a framework for levels of robot autonomy in HRI. To reach this goal, the framework draws links between HRI and human-automation interaction, a field with a long history of studying and understanding human-related variables. The construct of autonomy is reviewed and redefined within the context of HRI. Additionally, the framework proposes a process for determining a robot's autonomy level, by categorizing autonomy along a 10-point taxonomy. The framework is intended to be treated as guidelines to determine autonomy, categorize the LORA along a qualitative taxonomy, and consider which HRI variables (e.g., acceptance, situation awareness, reliability) may be influenced by the LORA.

  6. Glutathione--hydroxyl radical interaction: a theoretical study on radical recognition process.

    Directory of Open Access Journals (Sweden)

    Béla Fiser

    Full Text Available Non-reactive, comparative (2 × 1.2 μs molecular dynamics simulations were carried out to characterize the interactions between glutathione (GSH, host molecule and hydroxyl radical (OH(•, guest molecule. From this analysis, two distinct steps were identified in the recognition process of hydroxyl radical by glutathione: catching and steering, based on the interactions between the host-guest molecules. Over 78% of all interactions are related to the catching mechanism via complex formation between anionic carboxyl groups and the OH radical, hence both terminal residues of GSH serve as recognition sites. The glycine residue has an additional role in the recognition of OH radical, namely the steering. The flexibility of the Gly residue enables the formation of further interactions of other parts of glutathione (e.g. thiol, α- and β-carbons with the lone electron pair of the hydroxyl radical. Moreover, quantum chemical calculations were carried out on selected GSH/OH(• complexes and on appropriate GSH conformers to describe the energy profile of the recognition process. The relative enthalpy and the free energy changes of the radical recognition of the strongest complexes varied from -42.4 to -27.8 kJ/mol and from -21.3 to 9.8 kJ/mol, respectively. These complexes, containing two or more intermolecular interactions, would be the starting configurations for the hydrogen atom migration to quench the hydroxyl radical via different reaction channels.

  7. Quality of Life, Psychological Functioning, and Treatment Satisfaction of Men Who Have Undergone Penile Prosthesis Surgery Following Robot-Assisted Radical Prostatectomy.

    Science.gov (United States)

    Pillay, Brindha; Moon, Daniel; Love, Christopher; Meyer, Denny; Ferguson, Emma; Crowe, Helen; Howard, Nicholas; Mann, Sarah; Wootten, Addie

    2017-12-01

    treatment satisfaction between groups. Higher patient treatment satisfaction was more likely to be reported for couples whose depression scores were more similar. It is important to provide preoperative penile implant counseling and encourage patients to seek postoperative counseling if needed. This is one of the first Australian-based studies comprehensively assessing treatment satisfaction and psychosocial health of men after penile prosthesis surgery after RP. This was a retrospective cross-sectional study, so there is a possibility of recall bias, and causal associations could not be determined. Men in this Australian series who underwent penile prosthesis surgery after RP generally reported good sexual function and treatment satisfaction. Nevertheless, patient and partner mental health influenced their reported experience of the treatment. Pillay B, Moon D, Love C, et al. Quality of Life, Psychological Functioning, and Treatment Satisfaction of Men Who Have Undergone Penile Prosthesis Surgery Following Robot-Assisted Radical Prostatectomy. J Sex Med 2017;14:1612-1620. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  8. Radical chemo-irradiation using intensity-modulated radiotherapy for locally advanced head and neck cancer in elderly patients: Experience from a tertiary care center in South India.

    Science.gov (United States)

    Chalissery, J R; Sudheeran, P C; Varghese, K M; Venkatesan, K

    2016-01-01

    To assess the feasibility, tolerance and response of radical chemo irradiation using Intensity modulated Radiotherapy [IMRT] in elderly patients [age >65] with locally advanced head and neck cancer. Patients aged 65 and above [range 65 to 84years] registered in oncology outpatient unit in our institution between December 2011 to 2014, with stage III and IV head and neck cancer were treated with radical dose of radiotherapy using IMRT and concurrent chemotherapy with cisplatin 40mg/sq.m weekly. Response evaluation and toxicity profile assessment was done 6 to 8 weeks after completion of treatment and 3 monthly thereafter with median follow up of 3 years. Total number of patients analysed were 47. 43(91.5%) patients tolerated 66-.70Gy of radiotherapy and 4 or more cycles of weekly chemotherapy with cisplatin. First follow up evaluation at 6 to 8 weeks showed 81% patients having complete loco regional response. Grade III skin reaction and mucositis was noticed in 24% and 47% respectively. No grade III neutropenia observed. Median follow up of 3 years showed a complete local control in 53% and overall survival of 60%. Radical chemo irradiation with IMRT in elderly patients is a feasible option. Long term local control and overall survival benefits needs to be followed up.

  9. [Robot-aided training in rehabilitation].

    Science.gov (United States)

    Hachisuka, Kenji

    2010-02-01

    Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.

  10. Hydroxyl Radical-Mediated Novel Modification of Peptides: N-Terminal Cyclization through the Formation of α-Ketoamide.

    Science.gov (United States)

    Lee, Seon Hwa; Kyung, Hyunsook; Yokota, Ryo; Goto, Takaaki; Oe, Tomoyuki

    2015-01-20

    The hydroxyl radical-mediated oxidation of peptides and proteins constitutes a large group of post-translational modifications that can result in structural and functional changes. These oxidations can lead to hydroxylation, sulfoxidation, or carbonylation of certain amino acid residues and cleavage of peptide bonds. In addition, hydroxyl radicals can convert the N-terminus of peptides to an α-ketoamide via abstraction of the N-terminal α-hydrogen and hydrolysis of the ketimine intermediate. In the present study, we identified N-terminal cyclization as a novel modification mediated by a hydroxyl radical. The reaction of angiotensin (Ang) II (DRVYIHPF) and the hydroxyl radical generated by the Cu(II)/ascorbic acid (AA) system or UV/hydrogen peroxide system produced N-terminal cyclized-Ang II (Ang C) and pyruvamide-Ang II (Ang P, CH3COCONH-RVYIHPF). The structure of Ang C was confirmed by mass spectrometry and comparison to an authentic standard. The subsequent incubation of isolated Ang P in the presence of Cu(II)/AA revealed that Ang P was the direct precursor of Ang C. The proposed mechanism involves the formation of a nitrogen-centered (aminyl) radical, which cyclizes to form a five-membered ring containing the alkoxy radical. The subsequent β-scission reaction of the alkoxyl radical results in the cleavage of the terminal CH3CO group. The initial aminyl radical can be stabilized by chelation to the Cu(II) ions. The affinity of Ang C toward the Ang II type 1 receptor was significantly lower than that of Ang II or Ang P. Ang C was not further metabolized by aminopeptidase A, which converts Ang II to Ang III. Hydroxyl radical-mediated N-terminal cyclization was also observed in other Ang peptides containing N-terminal alanine, arginine, valine, and amyloid β 1-11 (DAEFRHDSGYE).

  11. Current status of robotic simulators in acquisition of robotic surgical skills.

    Science.gov (United States)

    Kumar, Anup; Smith, Roger; Patel, Vipul R

    2015-03-01

    This article provides an overview of the current status of simulator systems in robotic surgery training curriculum, focusing on available simulators for training, their comparison, new technologies introduced in simulation focusing on concepts of training along with existing challenges and future perspectives of simulator training in robotic surgery. The different virtual reality simulators available in the market like dVSS, dVT, RoSS, ProMIS and SEP have shown face, content and construct validity in robotic skills training for novices outside the operating room. Recently, augmented reality simulators like HoST, Maestro AR and RobotiX Mentor have been introduced in robotic training providing a more realistic operating environment, emphasizing more on procedure-specific robotic training . Further, the Xperience Team Trainer, which provides training to console surgeon and bed-side assistant simultaneously, has been recently introduced to emphasize the importance of teamwork and proper coordination. Simulator training holds an important place in current robotic training curriculum of future robotic surgeons. There is a need for more procedure-specific augmented reality simulator training, utilizing advancements in computing and graphical capabilities for new innovations in simulator technology. Further studies are required to establish its cost-benefit ratio along with concurrent and predictive validity.

  12. Strong exchange and magnetic blocking in N₂³⁻-radical-bridged lanthanide complexes.

    Science.gov (United States)

    Rinehart, Jeffrey D; Fang, Ming; Evans, William J; Long, Jeffrey R

    2011-05-22

    Single-molecule magnets approach the ultimate size limit for spin-based devices. These complexes can retain spin information over long periods of time at low temperature, suggesting possible applications in high-density information storage, quantum computing and spintronics. Notably, the success of most such applications hinges upon raising the inherent molecular spin-inversion barrier. Although recent advances have shown the viability of lanthanide-containing complexes in generating large barriers, weak or non-existent magnetic exchange coupling allows fast relaxation pathways that mitigate the full potential of these species. Here, we show that the diffuse spin of an N(2)(3-) radical bridge can lead to exceptionally strong magnetic exchange in dinuclear Ln(III) (Ln = Gd, Dy) complexes. The Gd(III) congener exhibits the strongest magnetic coupling yet observed for that ion, while incorporation of the high-anisotropy Dy(III) ion gives rise to a molecule with a record magnetic blocking temperature of 8.3 K at a sweep rate of 0.08 T s(-1).

  13. Part I. An investigation into the mechanism of the samarium (II)-promoted Barbier reaction: Sequential radical cyclization/organometallic addition. Part II. Conjugate addition reactions of organosamarium reagents by in situ transmetalation to cuprates. Part III. Approximate absolute rate constants for the reaction of tributyltin radicals with aryl and vinyl halides. Part IV. An investigation into the synthetic utility of tri-n-butylgermanium hydride

    Energy Technology Data Exchange (ETDEWEB)

    Totleben, M.J.

    1992-01-01

    An investigation of the mechanism of the samarium diiodide mediated Barbier reaction was conducted. Through a series of alkyl halide-carbonyl coupling and deuterium labelling experiments, evidence supportive of an organometallic addition mechanism was collected. Further probing led to an expansion of the utility of SmI[sub 2] in synthesis. The author has shown that radical cyclization of aryl and alkyl radicals to olefins, followed by reduction to primary and secondary organosamarium species is feasible. Organosamarium (III) reagents, produced by the reduction of alkyl and select aryl halides with 2 equiv of SmI[sub 2] in THF/HMPA, were treated with copper (I) salts and complexes to effect in situ transmetalation to cuprates. This allowed the 1,4-addition to [alpha],[beta]-unsaturated ketones. This new methodology allows for the sequential formation of carbon-carbon bonds through a combination of free radical and cuprate chemistry. Absolute rate constants for the abstraction of bromine atoms (k[sub Br]) by tri-n-butyltin radicals from a series of vinyl and aryl bromides have been determined. Atom abstraction was modestly enhanced by proximity of the halogen to a substituent in the following order: para < meta < ortho. Tri-n-butyl germanium hydride is known to be a poorer hydrogen atom donor than its tin analog. This feature makes it attractive for use in slow radical cyclizations where tin hydride would provide mainly for reduction. A brief study was executed to improve on the utility of the reagent as current conditions do not yield desired products in high amounts. Initial investigations examined the effect of initiator on reduction by germanium hydride, and subsequent experiments probed solvent effects. t-Butyl alcohol was determined to be superior to benzene or acetonitrile, giving consistently higher yields of reduction products.

  14. Predictive modelling of 2-year potency outcomes using a novel 90-day erection fullness scale after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Huynh, Linda M; Osann, Kathryn; Skarecky, Douglas; Ahlering, Thomas E

    2018-03-09

    To introduce a patient-reported erection fullness scale (%fullness) after robot-assisted radical prostatectomy (RARP) as a qualitative adjunct to the five-item version of the International Index of Erectile Function (IIEF-5) and as a 90-day predictor of 2-year potency outcomes. Prospective data were collected from 540 men with preoperative IIEF-5 scores of 22-25 who underwent RARP by a single surgeon, and of whom 299 had complete data at all time points up to 2 years. In addition to standard assessment tools (IIEF-5 and erections sufficient for intercourse [ESI]), the men were asked to 'indicate the fullness you are able to achieve in erections compared to before surgery?' (range: 0-100%). The primary outcome was prediction of potency (defined as ESI) at 24 months, based on 90-day %fullness tertile (0-24%, 25-74% and 75-100%). A total of 299 men with complete follow-up were included in the study. Significant predictors of 24-month potency included age, body mass index, pathological stage, nerve-sparing status and %fullness tertiles. When the men (preoperative IIEF-5 score 22-25) were assessed at 90 days after RARP, 181/299 (61%) had erections inadequate for intercourse. If IIEF-5 scores of 1-6 were used, 142/181 men (78%) would be targeted for early intervention. By contrast, if 0-24% fullness was used, 88/181 men (49%) would be targeted. If both the IIEF-5 score and %fullness were used, this would be reduced to 77/181 men (43%). We introduce %fullness as a qualitative adjunct to the IIEF-5 score, and separately as a 90-day predictor of 2-year potency recovery. This initial report is hypothesis-generating, such that the use of %fullness enables the identification of men who are most likely to benefit from early, secondary intervention. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  15. Development of a new free radical absorption capacity assay method for antioxidants: aroxyl radical absorption capacity (ARAC).

    Science.gov (United States)

    Nagaoka, Shin-ichi; Nagai, Kanae; Fujii, Yuko; Ouchi, Aya; Mukai, Kazuo

    2013-10-23

    A new free radical absorption capacity assay method is proposed with use of an aroxyl radical (2,6-di-tert-butyl-4-(4'-methoxyphenyl)phenoxyl radical) and stopped-flow spectroscopy and is named the aroxyl radical absorption capacity (ARAC) assay method. The free radical absorption capacity (ARAC value) of each tocopherol was determined through measurement of the radical-scavenging rate constant in ethanol. The ARAC value could also be evaluated through measurement of the half-life of the aroxyl radical during the scavenging reaction. For the estimation of the free radical absorption capacity, the aroxyl radical was more suitable than the DPPH radical, galvinoxyl, and p-nitrophenyl nitronyl nitroxide. The ARAC value in tocopherols showed the same tendency as the free radical absorption capacities reported previously, and the tendency was independent of an oxygen radical participating in the scavenging reaction and of a medium surrounding the tocopherol and oxygen radical. The ARAC value can be directly connected to the free radical-scavenging rate constant, and the ARAC method has the advantage of treating a stable and isolable radical (aroxyl radical) in a user-friendly organic solvent (ethanol). The ARAC method was also successfully applied to a palm oil extract. Accordingly, the ARAC method would be useful in free radical absorption capacity assay of antioxidative reagents and foods.

  16. A Human-Robot Interaction Perspective on Assistive and Rehabilitation Robotics.

    Science.gov (United States)

    Beckerle, Philipp; Salvietti, Gionata; Unal, Ramazan; Prattichizzo, Domenico; Rossi, Simone; Castellini, Claudio; Hirche, Sandra; Endo, Satoshi; Amor, Heni Ben; Ciocarlie, Matei; Mastrogiovanni, Fulvio; Argall, Brenna D; Bianchi, Matteo

    2017-01-01

    Assistive and rehabilitation devices are a promising and challenging field of recent robotics research. Motivated by societal needs such as aging populations, such devices can support motor functionality and subject training. The design, control, sensing, and assessment of the devices become more sophisticated due to a human in the loop. This paper gives a human-robot interaction perspective on current issues and opportunities in the field. On the topic of control and machine learning, approaches that support but do not distract subjects are reviewed. Options to provide sensory user feedback that are currently missing from robotic devices are outlined. Parallels between device acceptance and affective computing are made. Furthermore, requirements for functional assessment protocols that relate to real-world tasks are discussed. In all topic areas, the design of human-oriented frameworks and methods is dominated by challenges related to the close interaction between the human and robotic device. This paper discusses the aforementioned aspects in order to open up new perspectives for future robotic solutions.

  17. DSLs in robotics

    DEFF Research Database (Denmark)

    Schultz, Ulrik Pagh; Bordignon, Mirko; Stoy, Kasper

    2017-01-01

    Robotic systems blend hardware and software in a holistic way that intrinsically raises many crosscutting concerns such as concurrency, uncertainty, and time constraints. These concerns make programming robotic systems challenging as expertise from multiple domains needs to be integrated...... conceptually and technically. Programming languages play a central role in providing a higher level of abstraction. This briefing presents a case study on the evolution of domain-specific languages based on modular robotics. The case study on the evolution of domain-specific languages is based on a series...... of DSL prototypes developed over five years for the domain of modular, self-reconfigurable robots....

  18. Robots de servicio

    OpenAIRE

    Aracil, Rafael; Balaguer, Carlos; Armada, Manuel

    2008-01-01

    8 págs, 9 figs. El término Robots de Servicio apareció a finales de los años 80 como una necesidad de desarrollar máquinas y sistemas capaces de trabajar en entornos diferentes a los fabriles. Los Robots de Servicio tenían que poder trabajar en entornos noestructurados, en condiciones ambientales cambiantes y con una estrecha interacción con los humanos. En 1995 fue creado por la IEEE Robotics and Automation Society, el Technical Committee on Service Robots, y este comité definió en el año...

  19. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  20. Human-robot skills transfer interfaces for a flexible surgical robot.

    Science.gov (United States)

    Calinon, Sylvain; Bruno, Danilo; Malekzadeh, Milad S; Nanayakkara, Thrishantha; Caldwell, Darwin G

    2014-09-01

    In minimally invasive surgery, tools go through narrow openings and manipulate soft organs to perform surgical tasks. There are limitations in current robot-assisted surgical systems due to the rigidity of robot tools. The aim of the STIFF-FLOP European project is to develop a soft robotic arm to perform surgical tasks. The flexibility of the robot allows the surgeon to move within organs to reach remote areas inside the body and perform challenging procedures in laparoscopy. This article addresses the problem of designing learning interfaces enabling the transfer of skills from human demonstration. Robot programming by demonstration encompasses a wide range of learning strategies, from simple mimicking of the demonstrator's actions to the higher level imitation of the underlying intent extracted from the demonstrations. By focusing on this last form, we study the problem of extracting an objective function explaining the demonstrations from an over-specified set of candidate reward functions, and using this information for self-refinement of the skill. In contrast to inverse reinforcement learning strategies that attempt to explain the observations with reward functions defined for the entire task (or a set of pre-defined reward profiles active for different parts of the task), the proposed approach is based on context-dependent reward-weighted learning, where the robot can learn the relevance of candidate objective functions with respect to the current phase of the task or encountered situation. The robot then exploits this information for skills refinement in the policy parameters space. The proposed approach is tested in simulation with a cutting task performed by the STIFF-FLOP flexible robot, using kinesthetic demonstrations from a Barrett WAM manipulator. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Measuring Attitudes Towards Telepresence Robots

    OpenAIRE

    M Tsui, Katherine; Desai, Munjal; A. Yanco, Holly; Cramer, Henriette; Kemper, Nicander

    2011-01-01

    Studies using Nomura et al.’s “Negative Attitude toward Robots Scale” (NARS) [1] as an attitudinal measure have featured robots that were perceived to be autonomous, indepen- dent agents. State of the art telepresence robots require an explicit human-in-the-loop to drive the robot around. In this paper, we investigate if NARS can be used with telepresence robots. To this end, we conducted three studies in which people watched videos of telepresence robots (n=70), operated te...

  2. Robotic environments

    NARCIS (Netherlands)

    Bier, H.H.

    2011-01-01

    Technological and conceptual advances in fields such as artificial intelligence, robotics, and material science have enabled robotic architectural environments to be implemented and tested in the last decade in virtual and physical prototypes. These prototypes are incorporating sensing-actuating

  3. 2016 International Symposium on Experimental Robotics

    CERN Document Server

    Nakamura, Yoshihiko; Khatib, Oussama; Venture, Gentiane

    2017-01-01

    Experimental Robotics XV is the collection of papers presented at the International Symposium on Experimental Robotics, Roppongi, Tokyo, Japan on October 3-6, 2016. 73 scientific papers were selected and presented after peer review. The papers span a broad range of sub-fields in robotics including aerial robots, mobile robots, actuation, grasping, manipulation, planning and control and human-robot interaction, but shared cutting-edge approaches and paradigms to experimental robotics. The readers will find a breadth of new directions of experimental robotics. The International Symposium on Experimental Robotics is a series of bi-annual symposia sponsored by the International Foundation of Robotics Research, whose goal is to provide a forum dedicated to experimental robotics research. Robotics has been widening its scientific scope, deepening its methodologies and expanding its applications. However, the significance of experiments remains and will remain at the center of the discipline. The ISER gatherings are...

  4. Service Oriented Robotic Architecture for Space Robotics: Design, Testing, and Lessons Learned

    Science.gov (United States)

    Fluckiger, Lorenzo Jean Marc E; Utz, Hans Heinrich

    2013-01-01

    This paper presents the lessons learned from six years of experiments with planetary rover prototypes running the Service Oriented Robotic Architecture (SORA) developed by the Intelligent Robotics Group (IRG) at the NASA Ames Research Center. SORA relies on proven software engineering methods and technologies applied to space robotics. Based on a Service Oriented Architecture and robust middleware, SORA encompasses on-board robot control and a full suite of software tools necessary for remotely operated exploration missions. SORA has been eld tested in numerous scenarios of robotic lunar and planetary exploration. The experiments conducted by IRG with SORA exercise a large set of the constraints encountered in space applications: remote robotic assets, ight relevant science instruments, distributed operations, high network latencies and unreliable or intermittent communication links. In this paper, we present the results of these eld tests in regard to the developed architecture, and discuss its bene ts and limitations.

  5. Robot Control Overview: An Industrial Perspective

    Directory of Open Access Journals (Sweden)

    T. Brogårdh

    2009-07-01

    Full Text Available One key competence for robot manufacturers is robot control, defined as all the technologies needed to control the electromechanical system of an industrial robot. By means of modeling, identification, optimization, and model-based control it is possible to reduce robot cost, increase robot performance, and solve requirements from new automation concepts and new application processes. Model-based control, including kinematics error compensation, optimal servo reference- and feed-forward generation, and servo design, tuning, and scheduling, has meant a breakthrough for the use of robots in industry. Relying on this breakthrough, new automation concepts such as high performance multi robot collaboration and human robot collaboration can be introduced. Robot manufacturers can build robots with more compliant components and mechanical structures without loosing performance and robots can be used also in applications with very high performance requirements, e.g., in assembly, machining, and laser cutting. In the future it is expected that the importance of sensor control will increase, both with respect to sensors in the robot structure to increase the control performance of the robot itself and sensors outside the robot related to the applications and the automation systems. In this connection sensor fusion and learning functionalities will be needed together with the robot control for easy and intuitive installation, programming, and maintenance of industrial robots.

  6. Low cost submarine robot

    Directory of Open Access Journals (Sweden)

    Ponlachart Chotikarn

    2010-10-01

    Full Text Available A submarine robot is a semi-autonomous submarine robot used mainly for marine environmental research. We aim todevelop a low cost, semi-autonomous submarine robot which is able to travel underwater. The robot’s structure was designedand patented using a novel idea of the diving system employing a volume adjustment mechanism to vary the robot’s density.A light weight, flexibility and small structure provided by PVC can be used to construct the torpedo-liked shape robot.Hydraulic seal and O-ring rubbers are used to prevent water leaking. This robot is controlled by a wired communicationsystem.

  7. Physiology of free radicals

    Directory of Open Access Journals (Sweden)

    Stevanović Jelka

    2011-01-01

    Full Text Available Free radicals imply that every atom, molecule, ion, group of atoms, or molecules with one or several non-paired electrons in outer orbital. Among these are: nitrogenoxide (NO•, superoxide-anion-radical (O2•-, hydroxyl radical (OH•, peroxyl radical (ROO•, alcoxyl radical (RO• and hydroperoxyl radical (HO2•. However, reactive oxygen species also include components without non-paired electrons in outer orbital (so-called reactive non-radical agents, such as: singlet oxygen (1O2, peroxynitrite (ONOO-, hydrogen-peroxide (H2O2, hypochloric acid (eg. HOCl and ozone (O3. High concentrations of free radicals lead to the development of oxidative stress which is a precondition for numerous pathological effects. However, low and moderate concentrations of these matter, which occur quite normally during cell metabolic activity, play multiple significant roles in many reactions. Some of these are: regulation of signal pathways within the cell and between cells, the role of chemoattractors and leukocyte activators, the role in phagocytosis, participation in maintaining, changes in the position and shape of the cell, assisting the cell during adaption and recovery from damage (e.g.caused by physical effort, the role in normal cell growth, programmed cell death (apoptosis and cell ageing, in the synthesis of essential biological compounds and energy production, as well as the contribution to the regulation of the vascular tone, actually, tissue vascularization.

  8. Vision-Based Robot Following Using PID Control

    Directory of Open Access Journals (Sweden)

    Chandra Sekhar Pati

    2017-06-01

    Full Text Available Applications like robots which are employed for shopping, porter services, assistive robotics, etc., require a robot to continuously follow a human or another robot. This paper presents a mobile robot following another tele-operated mobile robot based on a PID (Proportional–Integral-Differential controller. Here, we use two differential wheel drive robots; one is a master robot and the other is a follower robot. The master robot is manually controlled and the follower robot is programmed to follow the master robot. For the master robot, a Bluetooth module receives the user’s command from an android application which is processed by the master robot’s controller, which is used to move the robot. The follower robot receives the image from the Kinect sensor mounted on it and recognizes the master robot. The follower robot identifies the x, y positions by employing the camera and the depth by using the Kinect depth sensor. By identifying the x, y, and z locations of the master robot, the follower robot finds the angle and distance between the master and follower robot, which is given as the error term of a PID controller. Using this, the follower robot follows the master robot. A PID controller is based on feedback and tries to minimize the error. Experiments are conducted for two indigenously developed robots; one depicting a humanoid and the other a small mobile robot. It was observed that the follower robot was easily able to follow the master robot using well-tuned PID parameters.

  9. ROBOTICS 2014 - The International Conference on ROBOTICS, Bucharest, Romania, October 23-24, 2014

    Directory of Open Access Journals (Sweden)

    Iulian TABĂRĂ

    2014-12-01

    Full Text Available ROBOTICS 2014 was organized by Robotics Society of Romania (RSR with the support of University POLITEHNICA of Bucharest (UPB, Institute of Solid Mechanics of the Romanian Academy (ISMRA and Technical University of Civil Engineering Bucharest (TUCEB, Ministry of National Education (MNE, under the patronage of International Federation for the Promotion of Mechanism and Machine Science (IFToMM. The first scientific event in the field of Robotics in Romania was held at the University POLITEHNICA of Bucharest (UPB, in 1981, by Professor Chrisitan PELECUDI, head of the Mechanisms and Robots research and design team MERO (MEchanisms and RObots and was named "National Symposium of Robotics ". Since the first edition have been held in Romania various scientific events dedicated to Robotics under the name of National Seminars (first fifteen events, since 1981 and National and International Conferences (last five editions. This is the 22nd edition of these scientific events, the first three (1981, 1982, and 1983 being held at the Polytechnic University of Bucharest.

  10. Robotic hand with modular extensions

    Science.gov (United States)

    Salisbury, Curt Michael; Quigley, Morgan

    2015-01-20

    A robotic device is described herein. The robotic device includes a frame that comprises a plurality of receiving regions that are configured to receive a respective plurality of modular robotic extensions. The modular robotic extensions are removably attachable to the frame at the respective receiving regions by way of respective mechanical fuses. Each mechanical fuse is configured to trip when a respective modular robotic extension experiences a predefined load condition, such that the respective modular robotic extension detaches from the frame when the load condition is met.

  11. Physical Human Robot Interaction for a Wall Mounting Robot - External Force Estimation

    DEFF Research Database (Denmark)

    Alonso García, Alejandro; Villarmarzo Arruñada, Noelia; Pedersen, Rasmus

    2018-01-01

    The use of collaborative robots enhances human capabilities, leading to better working conditions and increased productivity. In building construction, such robots are needed, among other tasks, to install large glass panels, where the robot takes care of the heavy lifting part of the job while...

  12. Engineering a horseradish peroxidase C stable to radical attacks by mutating multiple radical coupling sites.

    Science.gov (United States)

    Kim, Su Jin; Joo, Jeong Chan; Song, Bong Keun; Yoo, Young Je; Kim, Yong Hwan

    2015-04-01

    Peroxidases have great potential as industrial biocatalysts. In particular, the oxidative polymerization of phenolic compounds catalyzed by peroxidases has been extensively examined because of the advantage of this method over other conventional chemical methods. However, the industrial application of peroxidases is often limited because of their rapid inactivation by phenoxyl radicals during oxidative polymerization. In this work, we report a novel protein engineering approach to improve the radical stability of horseradish peroxidase isozyme C (HRPC). Phenylalanine residues that are vulnerable to modification by the phenoxyl radicals were identified using mass spectrometry analysis. UV-Vis and CD spectra showed that radical coupling did not change the secondary structure or the active site of HRPC. Four phenylalanine (Phe) residues (F68, F142, F143, and F179) were each mutated to alanine residues to generate single mutants to examine the role of these sites in radical coupling. Despite marginal improvement of radical stability, each single mutant still exhibited rapid radical inactivation. To further reduce inactivation by radical coupling, the four substitution mutations were combined in F68A/F142A/F143A/F179A. This mutant demonstrated dramatic enhancement of radical stability by retaining 41% of its initial activity compared to the wild-type, which was completely inactivated. Structure and sequence alignment revealed that radical-vulnerable Phe residues of HPRC are conserved in homologous peroxidases, which showed the same rapid inactivation tendency as HRPC. Based on our site-directed mutagenesis and biochemical characterization, we have shown that engineering radical-vulnerable residues to eliminate multiple radical coupling can be a good strategy to improve the stability of peroxidases against radical attack. © 2014 Wiley Periodicals, Inc.

  13. Vision-Based Robot Following Using PID Control

    OpenAIRE

    Chandra Sekhar Pati; Rahul Kala

    2017-01-01

    Applications like robots which are employed for shopping, porter services, assistive robotics, etc., require a robot to continuously follow a human or another robot. This paper presents a mobile robot following another tele-operated mobile robot based on a PID (Proportional–Integral-Differential) controller. Here, we use two differential wheel drive robots; one is a master robot and the other is a follower robot. The master robot is manually controlled and the follower robot is programmed to ...

  14. Chemical Properties And Toxicity of Chromium(III) Nutritional Supplements

    Energy Technology Data Exchange (ETDEWEB)

    Levina, A.; Lay, P.A.

    2009-05-19

    The status of Cr(III) as an essential micronutrient for humans is currently under question. No functional Cr(III)-containing biomolecules have been definitively described as yet, and accumulated experience in the use of Cr(III) nutritional supplements (such as [Cr(pic){sub 3}], where pic = 2-pyridinecarboxylato) has shown no measurable benefits for nondiabetic people. Although the use of large doses of Cr(III) supplements may lead to improvements in glucose metabolism for type 2 diabetics, there is a growing concern over the possible genotoxicity of these compounds, particularly of [Cr(pic){sub 3}]. The current perspective discusses chemical transformations of Cr(III) nutritional supplements in biological media, with implications for both beneficial and toxic actions of Cr(III) complexes, which are likely to arise from the same biochemical mechanisms, dependent on concentrations of the reactive species. These species include: (1) partial hydrolysis products of Cr(III) nutritional supplements, which are capable of binding to biological macromolecules and altering their functions; and (2) highly reactive Cr(VI/V/IV) species and organic radicals, formed in reactions of Cr(III) with biological oxidants. Low concentrations of these species are likely to cause alterations in cell signaling (including enhancement of insulin signaling) through interactions with the active centers of regulatory enzymes in the cell membrane or in the cytoplasm, while higher concentrations are likely to produce genotoxic DNA lesions in the cell nucleus. These data suggest that the potential for genotoxic side-effects of Cr(III) complexes may outweigh their possible benefits as insulin enhancers, and that recommendations for their use as either nutritional supplements or antidiabetic drugs need to be reconsidered in light of these recent findings.

  15. Why Robots Should Be Social: Enhancing Machine Learning through Social Human-Robot Interaction.

    Science.gov (United States)

    de Greeff, Joachim; Belpaeme, Tony

    2015-01-01

    Social learning is a powerful method for cultural propagation of knowledge and skills relying on a complex interplay of learning strategies, social ecology and the human propensity for both learning and tutoring. Social learning has the potential to be an equally potent learning strategy for artificial systems and robots in specific. However, given the complexity and unstructured nature of social learning, implementing social machine learning proves to be a challenging problem. We study one particular aspect of social machine learning: that of offering social cues during the learning interaction. Specifically, we study whether people are sensitive to social cues offered by a learning robot, in a similar way to children's social bids for tutoring. We use a child-like social robot and a task in which the robot has to learn the meaning of words. For this a simple turn-based interaction is used, based on language games. Two conditions are tested: one in which the robot uses social means to invite a human teacher to provide information based on what the robot requires to fill gaps in its knowledge (i.e. expression of a learning preference); the other in which the robot does not provide social cues to communicate a learning preference. We observe that conveying a learning preference through the use of social cues results in better and faster learning by the robot. People also seem to form a "mental model" of the robot, tailoring the tutoring to the robot's performance as opposed to using simply random teaching. In addition, the social learning shows a clear gender effect with female participants being responsive to the robot's bids, while male teachers appear to be less receptive. This work shows how additional social cues in social machine learning can result in people offering better quality learning input to artificial systems, resulting in improved learning performance.

  16. Why Robots Should Be Social: Enhancing Machine Learning through Social Human-Robot Interaction.

    Directory of Open Access Journals (Sweden)

    Joachim de Greeff

    Full Text Available Social learning is a powerful method for cultural propagation of knowledge and skills relying on a complex interplay of learning strategies, social ecology and the human propensity for both learning and tutoring. Social learning has the potential to be an equally potent learning strategy for artificial systems and robots in specific. However, given the complexity and unstructured nature of social learning, implementing social machine learning proves to be a challenging problem. We study one particular aspect of social machine learning: that of offering social cues during the learning interaction. Specifically, we study whether people are sensitive to social cues offered by a learning robot, in a similar way to children's social bids for tutoring. We use a child-like social robot and a task in which the robot has to learn the meaning of words. For this a simple turn-based interaction is used, based on language games. Two conditions are tested: one in which the robot uses social means to invite a human teacher to provide information based on what the robot requires to fill gaps in its knowledge (i.e. expression of a learning preference; the other in which the robot does not provide social cues to communicate a learning preference. We observe that conveying a learning preference through the use of social cues results in better and faster learning by the robot. People also seem to form a "mental model" of the robot, tailoring the tutoring to the robot's performance as opposed to using simply random teaching. In addition, the social learning shows a clear gender effect with female participants being responsive to the robot's bids, while male teachers appear to be less receptive. This work shows how additional social cues in social machine learning can result in people offering better quality learning input to artificial systems, resulting in improved learning performance.

  17. Vinylcyclopropylacyl and polyeneacyl radicals. Intramolecular ketene alkyl radical additions in ring synthesis.

    Science.gov (United States)

    De Boeck, Benoit; Herbert, Nicola M A; Harrington-Frost, Nicole M; Pattenden, Gerald

    2005-01-21

    Treatment of a variety of substituted vinylcyclopropyl selenyl esters, e.g. 11, with Bu(3)SnH-AIBN in refluxing benzene leads to the corresponding acyl radical intermediates, which undergo rearrangement and intramolecular cyclisations via their ketene alkyl radical equivalents producing cyclohexenones in 50-60% yield. By contrast, treatment of conjugated triene selenyl esters, e.g. 32, with Bu(3)SnH-AIBN produces substituted 2-cyclopentenones via intramolecular cyclisations of their ketene alkyl radical intermediates. Under the same radical-initiating conditions the selenyl esters derived from o-vinylbenzoic acid and o-vinylcinnamic acid undergo intramolecular cyclisations producing 1-indanone and 5,6-dihydrobenzocyclohepten-7-one respectively in 60-70% yields. A tandem radical cyclisation from the alpha,beta,gamma,delta-diene selenyl ester 31 provides an expeditious synthesis of the diquinane 35 in 69% yield.

  18. Robot Tracer with Visual Camera

    Science.gov (United States)

    Jabbar Lubis, Abdul; Dwi Lestari, Yuyun; Dafitri, Haida; Azanuddin

    2017-12-01

    Robot is a versatile tool that can function replace human work function. The robot is a device that can be reprogrammed according to user needs. The use of wireless networks for remote monitoring needs can be utilized to build a robot that can be monitored movement and can be monitored using blueprints and he can track the path chosen robot. This process is sent using a wireless network. For visual robot using high resolution cameras to facilitate the operator to control the robot and see the surrounding circumstances.

  19. Robotics for nuclear power plants

    International Nuclear Information System (INIS)

    Shiraiwa, Takanori; Watanabe, Atsuo; Miyasawa, Tatsuo

    1984-01-01

    Demand for robots in nuclear power plants is increasing of late in order to reduce workers' exposure to radiations. Especially, owing to the progress of microelectronics and robotics, earnest desire is growing for the advent of intellecturized robots that perform indeterminate and complicated security work. Herein represented are the robots recently developed for nuclear power plants and the review of the present status of robotics. (author)

  20. Robotics for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Shiraiwa, Takanori; Watanabe, Atsuo; Miyasawa, Tatsuo

    1984-10-01

    Demand for robots in nuclear power plants is increasing of late in order to reduce workers' exposure to radiations. Especially, owing to the progress of microelectronics and robotics, earnest desire is growing for the advent of intellecturized robots that perform indeterminate and complicated security work. Herein represented are the robots recently developed for nuclear power plants and the review of the present status of robotics.