WorldWideScience

Sample records for ii source detection

  1. Symbiotic Stars in X-rays. II. Faint Sources Detected with XMM-Newton and Chandra

    Nunez, N. E.; Luna, G. J. M.; Pillitteri, I.; Mukai, K.

    2014-01-01

    We report the detection from four symbiotic stars that were not known to be X-ray sources. These four object show a ß-type X-ray spectrum, that is, their spectra can be modeled with an absorbed optically thin thermal emission with temperatures of a few million degrees. Photometric series obtained with the Optical Monitor on board XMM-Newton from V2416 Sgr and NSV 25735 support the proposed scenario where the X-ray emission is produced in a shock-heated region inside the symbiotic nebulae.

  2. BEPC II positron source

    Pei Guoxi; Sun Yaolin; Liu Jintong; Chi Yunlong; Liu Yucheng; Liu Nianzong

    2006-01-01

    BEPC II-an upgrade project of the Beijing Electron Positron Collider (BEPC) is a factory type of e + e - collider. The fundamental requirements for its injector linac are the beam energy of 1.89 GeV for on-energy injection and a 40 mA positron beam current at the linac end with a low beam emittance of 1.6 μm and a low energy spread of ±0.5% so as to guarantee a higher injection rate (≥50 mA/min) to the storage ring. Since the positron flux is proportional to the primary electron beam power on the target, the authors will increase the electron gun current from 4A to 10A by using a new electron gun system and increase the primary electron energy from 120 MeV to 240 MeV. The positron source itself is an extremely important system for producing more positrons, including a positron converter target chamber, a 12kA flux modulator, the 7m focusing module with DC power supplies and the support. The new positron production linac from the electron gun to the positron source has been installed into the tunnel. In what follows, the authors will emphasize the positron source design, manufacture and tests. (authors)

  3. Dark matter detection - II

    Zacek, Viktor

    2015-01-01

    The quest for the mysterious missing mass of the universe has become one of the big challenges of today's particle physics and cosmology. Astronomical observations show that only 1% of the matter of the universe is luminous. Moreover there is now convincing evidence that 85% of all gravitationally observable matter in the universe is of a new exotic kind, different from the 'ordinary' matter surrounding us. In a series of three lectures we discuss past, recent and future efforts made world-wide to detect and/or decipher the nature of Dark Matter. In Lecture I we review our present knowledge of the Dark Matter content of the Universe and how experimenters search for it's candidates; In Lecture II we discuss so-called 'direct detection' techniques which allow to search for scattering of galactic dark matter particles with detectors in deep-underground laboratories; we discuss the interpretation of experimental results and the challenges posed by different backgrounds; In Lecture III we take a look at the 'indirect detection' of the annihilation of dark matter candidates in astrophysical objects, such as our sun or the center of the Milky Way; In addition we will have a look at efforts to produce Dark Matter particles directly at accelerators and we shall close with a look at alternative nonparticle searches and future prospects. (author)

  4. Moving Sources Detection System

    Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Normand, Stephane

    2013-06-01

    To monitor radioactivity passing through a pipe or in a given container such as a train or a truck, radiation detection systems are commonly employed. These detectors could be used in a network set along the source track to increase the overall detection efficiency. However detection methods are based on counting statistics analysis. The method usually implemented consists in trigging an alarm when an individual signal rises over a threshold initially estimated in regards to the natural background signal. The detection efficiency is then proportional to the number of detectors in use, due to the fact that each sensor is taken as a standalone sensor. A new approach is presented in this paper taking into account the temporal periodicity of the signals taken by all distributed sensors as a whole. This detection method is not based only on counting statistics but also on the temporal series analysis aspect. Therefore, a specific algorithm is then developed in our lab for this kind of applications and shows a significant improvement, especially in terms of detection efficiency and false alarms reduction. We also plan on extracting information from the source vector. This paper presents the theoretical approach and some preliminary results obtain in our laboratory. (authors)

  5. Searching for Compact Radio Sources Associated with UCH ii Regions

    Masqué, Josep M.; Trinidad, Miguel A.; Rodríguez-Rico, Carlos A. [Departamento de Astronomía, Universidad de Guanajuato, Apdo. Postal 144, 36000 Guanajuato, México (Mexico); Rodríguez, Luis F.; Kurtz, Stan; Loinard, Laurent [Instituto de Radioastronomía y Astrofísica, Universidad Nacional Autónoma de México, Morelia 58089, México (Mexico); Dzib, Sergio A. [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany)

    2017-02-10

    Ultra-compact (UC)H ii regions represent a very early stage of massive star formation. The structure and evolution of these regions are not yet fully understood. Interferometric observations showed in recent years that compact sources of uncertain nature are associated with some UCH ii regions. To examine this, we carried out VLA 1.3 cm observations in the A configuration of selected UCH ii regions in order to report additional cases of compact sources embedded in UCH ii regions. With these observations, we find 13 compact sources that are associated with 9 UCH ii regions. Although we cannot establish an unambiguous nature for the newly detected sources, we assess some of their observational properties. According to the results, we can distinguish between two types of compact sources. One type corresponds to sources that are probably deeply embedded in the dense ionized gas of the UCH ii region. These sources are photoevaporated by the exciting star of the region and will last for 10{sup 4}–10{sup 5} years. They may play a crucial role in the evolution of the UCH ii region as the photoevaporated material could replenish the expanding plasma and might provide a solution to the so-called lifetime problem of these regions. The second type of compact sources is not associated with the densest ionized gas of the region. A few of these sources appear resolved and may be photoevaporating objects such as those of the first type, but with significantly lower mass depletion rates. The remaining sources of this second type appear unresolved, and their properties are varied. We speculate on the similarity between the sources of the second type and those of the Orion population of radio sources.

  6. RTNS-II [Rotating Target Neutron Source II] operational summary

    Heikkinen, D.W.

    1988-09-01

    The Rotating Target Neutron Source II facility (RTNS-II) operated for over nine years. Its purpose was to provide high intensities of 14 MeV neutrons for materials studies in the fusion energy program. For the period from 1982-1987, the facility was supported by both the US (Department of Energy) and Japan (Ministry of Education, Culture, and Science). RTNS-II contains two accelerator-based neutron sources which use the T(d,n) 4 He reaction. In this paper, we will summarize the operational history of RTNS-II. Typical operating parameters are given. In addition, a brief description of the experimental program is presented. The current status and future options for the facility are discussed. 7 refs., 5 tabs

  7. FRM-II research neutron source commissioned

    Anon.

    2004-01-01

    On March 2, 2004, the Heinz Maier-Leibnitz research neutron source (FRM-II) generated neutrons for the first time. This marked the most important step on the way to using FRM-II for scientific purposes. On this occasion, this unique research facility in the world was dedicated in a ceremony attended by approximately 1000 representatives of politics, industry, and science. The keynote speaker, Federal Minister of the Interior Otto Schily; Bavarian Minister President Edmund Stoiber; Professor Claus Weyrich (Member of the Executive Board of Siemens AG); Dr. Thomas Goppel (Bavarian State Minister for Science, Research, and Arts); Professor Wolfgang A. Herman (President of the Technical University of Munich); Hannelore Gabor (2nd Mayor of the host municipality of Garching); and Professor Winfried Petry (Scientific Director of FRM-II) underlined the great importance of FRM-II for science, research, medicine, and technology. FRM-II will not only fill the 'neutron gap', but create extremely brilliant working conditions thanks to its considerably higher neutron flux compared to that of its predecessor, the legendary Atomic Egg. After the first conceptual design studies starting in 1980, the ground breaking ceremony in August 1996, and the third partial permit issued at Easter of 2003, a unique tool is now available for modern science and for medical and technical applications. (orig.) [de

  8. The Chandra Source Catalog: Background Determination and Source Detection

    McCollough, Michael; Rots, Arnold; Primini, Francis A.; Evans, Ian N.; Glotfelty, Kenny J.; Hain, Roger; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Danny G. Gibbs, II; Grier, John D.; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.; Zografou, Panagoula

    2009-09-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory are used to generate one of the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  9. Chandra Source Catalog: Background Determination and Source Detection

    McCollough, Michael L.; Rots, A. H.; Primini, F. A.; Evans, I. N.; Glotfelty, K. J.; Hain, R.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory will used to generate the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  10. Configuration of electro-optic fire source detection system

    Fabian, Ram Z.; Steiner, Zeev; Hofman, Nir

    2007-04-01

    The recent fighting activities in various parts of the world have highlighted the need for accurate fire source detection on one hand and fast "sensor to shooter cycle" capabilities on the other. Both needs can be met by the SPOTLITE system which dramatically enhances the capability to rapidly engage hostile fire source with a minimum of casualties to friendly force and to innocent bystanders. Modular system design enable to meet each customer specific requirements and enable excellent future growth and upgrade potential. The design and built of a fire source detection system is governed by sets of requirements issued by the operators. This can be translated into the following design criteria: I) Long range, fast and accurate fire source detection capability. II) Different threat detection and classification capability. III) Threat investigation capability. IV) Fire source data distribution capability (Location, direction, video image, voice). V) Men portability. ) In order to meet these design criteria, an optimized concept was presented and exercised for the SPOTLITE system. Three major modular components were defined: I) Electro Optical Unit -Including FLIR camera, CCD camera, Laser Range Finder and Marker II) Electronic Unit -including system computer and electronic. III) Controller Station Unit - Including the HMI of the system. This article discusses the system's components definition and optimization processes, and also show how SPOTLITE designers successfully managed to introduce excellent solutions for other system parameters.

  11. Detecting hidden sources-STUK/HUT team

    Nikkinen, M.; Aarnio, P. [Helsinki Univ. of Technology, Espoo (Finland); Honkamaa, T.; Tiilikainen, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    The task of the team was to locate and to identify hidden sources in a specified area in Padasjoki Auttoinen village. The team used AB-420 helicopter of the Finnish Frontier Guard. The team had two measuring systems: HPGe system (relative efficiency 18%) and 5`x5` NaI system. The team found two sources in real-time and additional two sources after 24 h analysis time. After the locations and characteristics of the sources were announced it was found out that altogether six sources would have been possible to find using the measured data. The total number of sources was ten. The NaI detector was good at detecting and locating the sources and HPGe was most useful in identification and calculation of the activity estimates. The following development should be made: 1) larger detectors are needed, 2) the software has to be improved. (This has been performed after the exercise) and 3) the navigation must be based on DGPS. visual navigation causes easily gaps between the flight lines and some sources may not be detected. (au).

  12. Detecting hidden sources-STUK/HUT team

    Nikkinen, M; Aarnio, P [Helsinki Univ. of Technology, Espoo (Finland); Honkamaa, T; Tiilikainen, H [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1998-12-31

    The task of the team was to locate and to identify hidden sources in a specified area in Padasjoki Auttoinen village. The team used AB-420 helicopter of the Finnish Frontier Guard. The team had two measuring systems: HPGe system (relative efficiency 18%) and 5`x5` NaI system. The team found two sources in real-time and additional two sources after 24 h analysis time. After the locations and characteristics of the sources were announced it was found out that altogether six sources would have been possible to find using the measured data. The total number of sources was ten. The NaI detector was good at detecting and locating the sources and HPGe was most useful in identification and calculation of the activity estimates. The following development should be made: 1) larger detectors are needed, 2) the software has to be improved. (This has been performed after the exercise) and 3) the navigation must be based on DGPS. visual navigation causes easily gaps between the flight lines and some sources may not be detected. (au).

  13. Improved selection criteria for H II regions, based on IRAS sources

    Yan, Qing-Zeng; Xu, Ye; Walsh, A. J.; Macquart, J. P.; MacLeod, G. C.; Zhang, Bo; Hancock, P. J.; Chen, Xi; Tang, Zheng-Hong

    2018-05-01

    We present new criteria for selecting H II regions from the Infrared Astronomical Satellite (IRAS) Point Source Catalogue (PSC), based on an H II region catalogue derived manually from the all-sky Wide-field Infrared Survey Explorer (WISE). The criteria are used to augment the number of H II region candidates in the Milky Way. The criteria are defined by the linear decision boundary of two samples: IRAS point sources associated with known H II regions, which serve as the H II region sample, and IRAS point sources at high Galactic latitudes, which serve as the non-H II region sample. A machine learning classifier, specifically a support vector machine, is used to determine the decision boundary. We investigate all combinations of four IRAS bands and suggest that the optimal criterion is log(F_{60}/F_{12})≥ ( -0.19 × log(F_{100}/F_{25})+ 1.52), with detections at 60 and 100 {μ}m. This selects 3041 H II region candidates from the IRAS PSC. We find that IRAS H II region candidates show evidence of evolution on the two-colour diagram. Merging the WISE H II catalogue with IRAS H II region candidates, we estimate a lower limit of approximately 10 200 for the number of H II regions in the Milky Way.

  14. Detection of OH radicals from IRAS sources

    Lewis, B.M.; Eder, J.; Terzian, Y.

    1985-01-01

    An efficient method for detecting new OH/infrared stars is to begin with IRAS source positions, selected for appropriate infrared colours, and using radio-line observations to confirm the OH properties. The authors demonstrate the validity of this approach here, using the Arecibo 305 m radio-telescope to confirm the 1,612 MHz line observations of sources in IRAS Circulars 8 and 9; the present observations identify 21 new OH/infrared stars. The new sources have weaker 1,612 MHz fluxes, bluer (60-25) μm colours and a smaller mean separation between the principal emission peaks than previous samples. (author)

  15. Multi-Channel Tunable Source for Atomic Sensors, Phase II

    National Aeronautics and Space Administration — This Phase II SBIR will seek to develop a prototype laser source suitable for atomic interferometry from compact, robust, integrated components. AdvR's design is...

  16. Current status for TRR-II Cold Neutron Source

    Lee, C.H.; Guung, T.C.; Lan, K.C.; Wang, C.H.; Chan, Y.K.; Shieh, D.J.

    2001-01-01

    The Taiwan Research Reactor (TRR) project (TRR-II) is carrying out at Institute of Nuclear Energy Research (INER) from October 1998 to December 2006. The purpose of Cold Neutron Source (CNS) project is to build entire CNS facility to generate cold neutrons within TRR-II reactor. The objective of CNS design is to install CNS facility with a competitive brightness of cold neutron beam to other facilities in the world. Based on the TRR-II CNS project schedule, the conceptual design for TRR-II CNS facility has been completed and the mock-up test facility for full-scale hydrogen loop has been designed. (author)

  17. Gas discharge ion source. II. Duopigatron

    Bacon, F.M.; Bickes, R.W. Jr.; O'Hagan, J.B.

    1978-01-01

    Ion source performance characteristics consisting of total ion current, ion energy distribution, mass distribution, and ion current density distribution have been measured for several models of a duopigatron. Variations on the duopigatron design involved plasma expansion cup material and dimensions, secondary cathode material, and interelectrode spacings. Of the designs tested, the one with a copper and molybdenum secondary cathode, and a mild steel plasma expansion cup proved to give the best results. The ion current density distribution was peaked at the center of the plasma expansion cup and fell off to 80% of the peak value at the cup wall for a cup 15.2 mm deep. A total ion current of 180 mA consisting of 60%-70% atomic ions was produced with an arc current of 20 A and source pressure of 9.3 Pa. More shallow cups produced a larger beam current and a more sharply peaked ion current density distribution. Typical ion energy distributions were bellshaped curves with a peak 10-20 V below anode potential and with ion energies extending 30-40 V on either side of the peak

  18. Phase II beam lines at the National Synchrotron Light Source

    Thomlinson, W.

    1984-06-01

    The expansion of the National Synchrotron Light Source has been funded by the US Department of Energy. The Phase II program consists of both increased conventional facilities and six new beam lines. In this paper, an overview of the six beam lines which will be constructed during Phase II is presented. For five of the lines special radiation sources are necessary and the designs of four of the devices are complete. The relevant parameters of the insertion devices under construction and development are presented

  19. Distributed Impact Detection System, Phase II

    National Aeronautics and Space Administration — Automated impact detection and characterization on manned spacecraft has been an elusive goal due to the transitory nature of the detectable high-frequency signals....

  20. Impedance-Source Networks for Electric Power Conversion Part II

    Siwakoti, Yam P.; Peng, Fang Zheng; Blaabjerg, Frede

    2015-01-01

    Impedance-source networks cover the entire spectrum of electric power conversion applications (dc-dc, dc-ac, ac-dc, ac-ac) controlled and modulated by different modulation strategies to generate the desired dc or ac voltage and current at the output. A comprehensive review of various impedance......-source-network-based power converters has been covered in a previous paper and main topologies were discussed from an application point of view. Now Part II provides a comprehensive review of the most popular control and modulation strategies for impedance-source network-based power converters/inverters. These methods...

  1. Research applications of the Livermore RTNS-II neutron sources

    Davis, J.C.

    1978-01-01

    The Lawrence Livermore Laboratory has completed construction of the Rotating Target Neutron Source-II (RTNS-II) Facility. These sources, built and operated for the Office of Fusion Energy of the Department of Energy, will be operated by LLL as a national facility for the study of materials damage processes induced by 14-MeV neutrons. Design strength of the sources is 4 x 10 13 n/s with a maximum flux of 1 X 10 13 n/cm 2 s. The 400 keV, 150 mA D + accelerators and 5000 rpm titanium--tritide target assemblies were built using experience gained with LLL's RTNS-I neutron source. The RTNS-I source, producing 6 x 10 12 n/s, is currently the most intense 14-MeV source available. RTNS-I has been used for fusion reactor materials studies for the past six years. The experimental program for the new sources will be oriented toward fundamental measurements of high energy neutron-induced effects. The data produced will be used to develop models of damage processes to help guide materials selection for future fusion reactors

  2. MEMS Gyroscope with Interferometric Detection, Phase II

    National Aeronautics and Space Administration — The proposed innovation is a novel MEMS gyroscope that uses micro-interferometric detection to measure the motion of the proof mass. Using an interferometric...

  3. Indirect detection of radiation sources through direct detection of radiolysis products

    Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA

    2010-04-20

    A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

  4. Status of the FRM-II hot neutron source

    Mueller, C.; Gutsmiedl, E.

    2001-01-01

    The new research reactor FRM-II will be equipped with a hot neutron source. This secondary source will shift a part of the thermal neutron energy spectrum in the D 2 O moderator to energies from 0.1 to 1 eV. The hot neutron source consists of a graphite cylinder (200 mm diameter, 300 mm high), which is heated by gamma radiation up to a maximum temperature of about 2400 C. The graphite cylinder is surrounded by a high-temperature insulation of carbon fiber, to achieve this high temperature. We have accomplished mock-up tests of the carbon fiber in a high temperature furnace, to investigate the insulation properties of the material. The graphite cylinder and the insulation are covered with two vessels made out of Zircaloy 4. The space between the vessels is filled with helium. The hot neutron source is permanent under control by pressure and temperature measurements. The temperature inside the graphite cylinder will be measured by a purpose-built noise thermometer due to the extremely harsh environment conditions (temperature and nuclear radiation). The hot neutron source is designed and manufactured according to the general specification basic safety and to the German nuclear atomic rules (KTA). The source will be installed in year 2001. (orig.)

  5. LEVIS lithium ion source experiments on PBFA-II

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Lopez, M.; Clark, B.F.; Schroeder, J.; Bailey, J.E.; Filuk, A.B.; Carlson, A.L.

    1992-01-01

    PBFA-II is a pulsed power generator designed to apply up to a 25 MV, 20 ns pulse to a focusing 15 cm-radius Applied-B ion diode for inertial confinement fusion applications. Several different approaches have been pursued to produce a high-purity (> 90%), high-current density (5--10 kA/cm 2 ) singly ionized lithium ion source for acceleration in this diode. In addition to having high source purity, such a source should be active, i.e. the ions should be produced before the power pulse arrives, to provide better electrical coupling from the accelerator to the diode. In the LEVIS (Laser EVaporation Ion Source) process, energy from two lasers impinges on a thin (500 nm) lithium or lithium-bearing film on an insulating substrate. The authors will discuss a new series of LEVIS experiments, with a number of improvements: (1) the laser distribution cone was redesigned, resulting in a more uniform illumination of the 4 cm-tall Li-producing surface; (2) the anode surface is being slow-heated to 120--150 C to help drive off contaminants; and (3) they have expanded the number of source and beam diagnostics

  6. Concepts of UCN sources for the FRM-II

    Trinks, U; Paul, S; Schott, W

    2000-01-01

    Three concepts for sources of ultra-cold neutrons (UCN) for the reactor FRM-II at Garching near Munich are studied: one, Mini-D sub 2 , is a source with 170 cm sup 3 of solid deuterium in the beam tube SR4 and the second one a large solid-deuterium source (volume about 30 dm sup 3), mounted in the beam tube SR5 as an advanced cold source with a number of neutron guides. The third one, Mark 3000, uses superfluid sup 4 He at a cold-neutron guide. A UCN density of up to 7x10 sup 4 cm sup - sup 3 may possibly be achieved in the storage volumes of Mini-D sub 2 yielding more than 10 sup 9 UCN for extraction to an attached experimental setup. The usable UCN flux at the periphery of the large deuterium source is predicted to be 2x10 sup 7 cm sup - sup 2 s sup - sup 1. Mark 3000, finally, is expected to yield a UCN density of about 10 sup 5 cm sup - sup 3.

  7. Intrusion Detection using Open Source Tools

    Jack TIMOFTE

    2008-01-01

    We have witnessed in the recent years that open source tools have gained popularity among all types of users, from individuals or small businesses to large organizations and enterprises. In this paper we will present three open source IDS tools: OSSEC, Prelude and SNORT.

  8. Ionizing radiation source detection by personal TLD

    Marinkovic, O.; Mirkov, Z.

    2002-01-01

    The Laboratory for personal dosimetry has about 3000 workers under control. The most of them work in medicine. Some institutions, as big health centers, have different ionizing radiation sources. It is usefull to analyze what has been the source of irradiation, special when appears a dosimeter with high dose. Personal dosimetry equipment is Harshaw TLD Reader Model 6600 and dosimeters consist of two chips LiF TLD-100 assembled in bar-coded cards which are wearing in holders with one tissue-equivalent filter (to determine H(10)) and skin-equivalent the other (to determine H(0.07)). The calibration dosimeters have been irradiated in holders by different sources: x-ray (for 80keV and 100keV), 6 0C o, 9 0S r (for different distances from beta source) and foton beem (at radiotherapy accelerator by 6MeV, 10MeV and 18MeV). The dose ratio for two LiF cristals was calculated and represented with graphs. So, it is possible to calculate the ratio H(10)/H(0.07) for a personal TLD and analyze what has been the source of irradiation. Also, there is the calibration for determination the time of irradiation, according to glow curve deconvolution

  9. Detection of criticality accidents. The Intertechnique EDAC II system

    Prigent, R.

    1991-01-01

    The chief aim of the new generation of EDAC II criticality accidents detection system is to reduce the risks associated to the handling of fissile material by providing a swift and safe warning of the development of any criticality accident. To this function already devolving on the EDAC system of the previous generation, the EDAC II adds the possibility of storing in memory the characteristics of the accident, providing a daily follow-up of the striking events in the system through the print-out of a log book and providing assistance to the operators during the periodical tests. (Author)

  10. Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

    Stohr, J.

    2011-01-01

    The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that LCLS-II only

  11. Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

    Stohr, J

    2011-11-16

    The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that

  12. Tank waste source term inventory validation. Volume II. Letter report

    NONE

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories.

  13. Tank waste source term inventory validation. Volume II. Letter report

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories

  14. Background sources and masks for Mark II detector at PEP

    Kadyk, J.

    1981-06-01

    The shielding masks currently at use in several of the current experiments at PEP are the result of an early organized effort to understand the sources of particle background expected at PEP, followed by the evolution of the conceptual designs into actual hardware. The degree and kind of background particle loading which could be tolerated was expected to differ significantly among the different experiments, and several designs emerged from the common study. Qualitatively, the types of radiations studied were, Synchrotron Radiation (SR), Beam Gas Bremsstrahlung (BGB), and, to a limited extent others, e.g., Electroproduction (EP). Calculations will be given of predicted occupancies in the pipe counter and other sensitive elements at small radius, since these will be most susceptible to the SR and BGB backgrounds. The calculations presented in this note are specific to the Mark II detector. Some general statements will be made first about the character of each of the various types of backgrounds considered, then some detailed calculations made for application to the Mark II detector

  15. EBR-II water-to-sodium leak detection system

    Wrightson, M.M.; McKinley, K.; Ruther, W.E.; Holmes, J.T.

    1976-01-01

    The water-to-sodium leak detection system installed at EBR-II in April, 1975, is described in detail. Topics covered include operational characteristics, maintenance problems, alarm functions, background hydrogen level data, and future plans for refinements to the system. Particular emphasis is given to the failures of eight of the ten leak detectors due to sodium-to-vacuum leakage, and the program anticipated for complete recovery of the system

  16. Tetrodotoxin: Chemistry, Toxicity, Source, Distribution and Detection

    Vaishali Bane

    2014-02-01

    Full Text Available Tetrodotoxin (TTX is a naturally occurring toxin that has been responsible for human intoxications and fatalities. Its usual route of toxicity is via the ingestion of contaminated puffer fish which are a culinary delicacy, especially in Japan. TTX was believed to be confined to regions of South East Asia, but recent studies have demonstrated that the toxin has spread to regions in the Pacific and the Mediterranean. There is no known antidote to TTX which is a powerful sodium channel inhibitor. This review aims to collect pertinent information available to date on TTX and its analogues with a special emphasis on the structure, aetiology, distribution, effects and the analytical methods employed for its detection.

  17. Detection of antibiotic residues in food by Charm II test

    Addali, Mohamed

    2014-01-01

    Antibiotics are used in food to: -therapy and prophylaxis, -increase the productivity of the food producing animals. The presence of antimicrobial residues: -constitutes a potential human health hazard. has significant impact on international food trade. has implications on technological process in dairy industry. Detection of antibiotic residues is of great interest. It helps protect humans against the effects of such residues, the more it can support the participation of our country in international trade. Charm II test is one of the methods of detection of antimicrobial residues. The tests utilize microbial or antibody receptor assay technology. The sample is incubated with a binding agent (microbial cells with specific receptor sites or with specific antibodies attached) and a tracer (the radio-labeled version of the antibiotic to be detected). The amount of tracer on the binding agent is measured using a scintillation counter and is compared to a pre-determined cut-off or control point. If contaminating antibiotic is present, it will prevent the binding of the tracer by occupying the receptors on the binding agent. The less labeled tracer detected, the more contaminating antibiotic there is present in the sample. This work, carried out at the Radiochemical Laboratory of the National Centre of Nuclear Science and Technology, has two parts: 1/ The first is reserved to a literature review provides an overview on antibiotics and the charm II method. 2/ The second is devoted to the experimental study and presentation of results.

  18. 21-cm signature of the first sources in the Universe: prospects of detection with SKA

    Ghara, Raghunath; Choudhury, T. Roy; Datta, Kanan K.

    2016-07-01

    Currently several low-frequency experiments are being planned to study the nature of the first stars using the redshifted 21-cm signal from the cosmic dawn and Epoch of Reionization. Using a one-dimensional radiative transfer code, we model the 21-cm signal pattern around the early sources for different source models, I.e. the metal-free Population III (PopIII) stars, primordial galaxies consisting of Population II (PopII) stars, mini-QSOs and high-mass X-ray binaries (HMXBs). We investigate the detectability of these sources by comparing the 21-cm visibility signal with the system noise appropriate for a telescope like the SKA1-low. Upon integrating the visibility around a typical source over all baselines and over a frequency interval of 16 MHz, we find that it will be possible to make a ˜9σ detection of the isolated sources like PopII galaxies, mini-QSOs and HMXBs at z ˜ 15 with the SKA1-low in 1000 h. The exact value of the signal-to-noise ratio (SNR) will depend on the source properties, in particular on the mass and age of the source and the escape fraction of ionizing photons. The predicted SNR decreases with increasing redshift. We provide simple scaling laws to estimate the SNR for different values of the parameters which characterize the source and the surrounding medium. We also argue that it will be possible to achieve an SNR ˜9 even in the presence of the astrophysical foregrounds by subtracting out the frequency-independent component of the observed signal. These calculations will be useful in planning 21-cm observations to detect the first sources.

  19. Detecting the Lμ-Lτ gauge boson at Belle II

    Araki, Takeshi; Hoshino, Shihori; Ota, Toshihiko; Sato, Joe; Shimomura, Takashi

    2017-03-01

    We discuss the feasibility of detecting the gauge boson of the U (1 )Lμ-Lτ symmetry, which possesses a mass in the range between MeV and GeV, at the Belle-II experiment. The kinetic mixing between the new gauge boson Z' and photon is forbidden at the tree level and is radiatively induced. The leptonic force mediated by such a light boson is motivated by the discrepancy in muon anomalous magnetic moment and also the gap in the energy spectrum of cosmic neutrino. Defining the process e+e-→γ Z'→γ ν ν ¯ (missing energy) to be the signal, we estimate the numbers of the signal and the background events and show the parameter region to which the Belle-II experiment will be sensitive. The signal process in the Lμ-Lτ model is enhanced with a light Z', which is a characteristic feature differing from the dark photon models with a constant kinetic mixing. We find that the Belle-II experiment with the design luminosity will be sensitive to the Z' with the mass MZ'≲1 GeV and the new gauge coupling gZ'≳8 ×10-4 , which covers a half of the unconstrained parameter region that explains the discrepancy in muon anomalous magnetic moment. The possibilities to improve the significance of the detection are also discussed.

  20. Electrochemical Microsensors for the Detection of Cadmium(II and Lead(II Ions in Plants

    Olga Krystofova

    2010-05-01

    Full Text Available Routine determination of trace metals in complex media is still a difficult task for many analytical instruments. The aim of this work was to compare three electro-chemical instruments [a standard potentiostat (Autolab, a commercially available miniaturized potentiostat (PalmSens and a homemade micropotentiostat] for easy-to-use and sensitive determination of cadmium(II and lead(II ions. The lowest detection limits (hundreds of pM for both metals was achieved by using of the standard potentiostat, followed by the miniaturized potentiostat (tens of nM and the homemade instrument (hundreds of nM. Nevertheless, all potentiostats were sensitive enough to evaluate contamination of the environment, because the environmental limits for both metals are higher than detection limits of the instruments. Further, we tested all used potentiostats and working electrodes on analysis of environmental samples (rainwater, flour and plant extract with artificially added cadmium(II and lead(II. Based on the similar results obtained for all potentiostats we choose a homemade instrument with a carbon tip working electrode for our subsequent environmental experiments, in which we analyzed maize and sunflower seedlings and rainwater obtained from various sites in the Czech Republic.

  1. Induced Temporal Signatures for Point-Source Detection

    Stephens, Daniel L.; Runkle, Robert C.; Carlson, Deborah K.; Peurrung, Anthony J.; Seifert, Allen; Wyatt, Cory R.

    2005-01-01

    Detection of radioactive point-sized sources is inherently divided into two regimes encompassing stationary and moving detectors. The two cases differ in their treatment of background radiation and its influence on detection sensitivity. In the stationary detector case the statistical fluctuation of the background determines the minimum detectable quantity. In the moving detector case the detector may be subjected to widely and irregularly varying background radiation, as a result of geographical and environmental variation. This significant systematic variation, in conjunction with the statistical variation of the background, requires a conservative threshold to be selected to yield the same false-positive rate as the stationary detection case. This results in lost detection sensitivity for real sources. This work focuses on a simple and practical modification of the detector geometry that increase point-source recognition via a distinctive temporal signature. A key part of this effort is the integrated development of both detector geometries that induce a highly distinctive signature for point sources and the development of statistical algorithms able to optimize detection of this signature amidst varying background. The identification of temporal signatures for point sources has been demonstrated and compared with the canonical method showing good results. This work demonstrates that temporal signatures are efficient at increasing point-source discrimination in a moving detector system

  2. Number of detectable kaon decays at LAMPF II

    Sanford, T.W.L.

    1982-04-01

    The maximum number of kaon decays detectable at LAMPF II is estimated for both in-flight and stopping decays. Under reasonable assumptions, the momentum of the kaon beam that optimizes the decay yield occurs at about 6 GeV/c and 600 MeV/c for in-flight and stopping decays, respectively. K + decay yields are fo the order of 7 x 10 7 per 10 14 interacting with K - yields being typically 5 times less. By measuring decays from such beams, a statistical limit of 10 -15 on a branching ratio to a particular channel can be placed in a 100-day run. The large number of kaon decays available at LAMPF II thus provides a powerful tool for sensitively examining rare-decay processes of the kaon

  3. Thermal flow in detectors of CNA-II with spontaneous fissions source of 238U

    Mascitti, J. A

    2012-01-01

    The thermal flux in the position of ex-core and in-core CNA-II Nuclear Power Plant (CNA-II) detectors is estimated considering neutron from the 238 U spontaneous fissions as the source, for the reactor cold state (isothermal state with both coolant and moderator at a temperature of 60 o C, a pressure of 35 ata and 15.46 ppm of natural Boron), and 24% inserted control rods (slightly sub-critical). Results are obtained for two different situations: with and without photo-neutrons due to the (γ,n) reaction in D 2 O. It is concluded that the thermal flux is under the detection limit of the boron trifluoride 104-SR or 282-IB detectors (≅10 -1 cm-2.s -1 ). These detectors are located in opposite positions in the inner concrete shielding, having the lowest detection limit among all ex-core detectors. A significant difference is verified in neutron fluxes between both cases, which suggest that photo-neutrons in large heavy water reactors such as CNA-II should not be ignored. The total neutron flux attenuation factor between the inner and outer region of the reactor pressure vessel was estimated to be 7.0 x 10 -7 . It should be mentioned that none of the results here presented has been affected by any correction factor. Each value has a percentage relative error representing the statistical uncertainty due to the probabilistic Monte Carlo method used to obtain it (author)

  4. OpenMC In Situ Source Convergence Detection

    Aldrich, Garrett Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Univ. of California, Davis, CA (United States); Dutta, Soumya [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); The Ohio State Univ., Columbus, OH (United States); Woodring, Jonathan Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-07

    We designed and implemented an in situ version of particle source convergence for the OpenMC particle transport simulator. OpenMC is a Monte Carlo based-particle simulator for neutron criticality calculations. For the transport simulation to be accurate, source particles must converge on a spatial distribution. Typically, convergence is obtained by iterating the simulation by a user-settable, fixed number of steps, and it is assumed that convergence is achieved. We instead implement a method to detect convergence, using the stochastic oscillator for identifying convergence of source particles based on their accumulated Shannon Entropy. Using our in situ convergence detection, we are able to detect and begin tallying results for the full simulation once the proper source distribution has been confirmed. Our method ensures that the simulation is not started too early, by a user setting too optimistic parameters, or too late, by setting too conservative a parameter.

  5. Plagiarism and Source Deception Detection Based on Syntax Analysis

    Eman Salih Al-Shamery

    2017-02-01

    Full Text Available In this research, the shingle algorithm with Jaccard method are employed as a new approach to detect deception in sources in addition to detect plagiarism . Source deception occurs as a result of taking a particular text from a source and relative it to another source, while plagiarism occurs in the documents as a result of taking part or all of the text belong to another research, this approach is based on Shingle algorithm with Jaccard coefficient , Shingling is an efficient way to compare the set of shingle in the files that contain text which are used as a feature to measure the syntactic similarity of the documents and it will work with Jaccard coefficient that measures similarity between sample sets . In this proposed system, text will be checked whether it contains syntax plagiarism or not and gives a percentage of similarity with other documents , As well as research sources will be checked to detect deception in source , by matching it with available sources from Turnitin report of the same research by using shingle algorithm with Jaccard coefficient. The motivations of this work is to discovery of literary thefts that occur on the researches , especially what students are doing in their researches , also discover the deception that occurs in the sources.

  6. Status of TRR-II cold neutron source

    Lee, C.H.; Guung, T.C.; Lan, K.C.; Chan, Y.K.; Wang, C.H.; Chen, S.K.

    2001-01-01

    The Taiwan research reactor improvement and the utilization promotion project (TRR-II) with a vertical cold neutron source (CNS) is carrying out at the Institute of Nuclear Energy Research (INER). The CNS with a two-phase thermosiphon loop consists of an annular cylindrical moderator cell, a single moderator transfer tube and a condenser. A cylindrical annulus moderator cell with boiling liquid hydrogen at 1.2 bar and 20.7 K gives an optimum moderation for cold neutrons in the wavelength range between 4 A and 15 A. The moderator cell lies around 400 mm away from the core center. Its perturbed thermal flux is about 1.4 x 10 14 cm -2 s -1 . It is close to the maximum thermal neutron flux area in D 2 O tank to get the maximum possible brightness about 1 x 10 12 n cm -2 s -1 A -1 sterad -1 at 4 A. An experimental study for thermal-hydraulic characteristics of the two-phase thermosiphon loop has been performed on a full-scale mockup loop using a Freon-11 as a working fluid. The objective of the mockup testing is to validate operation and heat removal capacity in CNS hydrogen loop design. Moreover, this loop will be used to demonstrate no onset of flooding and flow oscillations in a single transfer tube under CNS normal and abnormal conditions. The flooding limitation, the liquid level, and the void fraction in the moderator cell as a function of the initial Freon-11 inventory, the heat load, and the moderator cell geometry are also reported. (orig.)

  7. Research on point source simulating the γ-ray detection efficiencies of stander source

    Tian Zining; Jia Mingyan; Shen Maoquan; Yang Xiaoyan; Cheng Zhiwei

    2010-01-01

    For φ 75 mm x 25 mm sample, the full energy peak efficiencies on different heights of sample radius were obtained using the point sources, and the function parameters about the full energy peak efficiencies of point sources based on radius was fixed. The 59.54 keV γ-ray, 661.66 keV γ-ray, 1173.2 keV γ-ray, 1332.5 keV γ-ray detection efficiencies on different height of samples were obtained, based on the full energy peak efficiencies of point sources and its height, and the function parameters about the full energy peak efficiencies of surface sources based on sample height was fixed. The detection efficiency of (75 mm x 25 mm calibration source can be obtained by integrality, the detection efficiencies simulated by point sources are consistent with the results of stander source in 10%. Therefore, the calibration method of stander source can be substituted by the point source simulation method, and it tis feasible when there is no stander source.) (authors)

  8. Detection of supernova neutrinos at spallation neutron sources

    Huang, Ming-Yang; Guo, Xin-Heng; Young, Bing-Lin

    2016-07-01

    After considering supernova shock effects, Mikheyev-Smirnov-Wolfenstein effects, neutrino collective effects, and Earth matter effects, the detection of supernova neutrinos at the China Spallation Neutron Source is studied and the expected numbers of different flavor supernova neutrinos observed through various reaction channels are calculated with the neutrino energy spectra described by the Fermi-Dirac distribution and the “beta fit” distribution respectively. Furthermore, the numerical calculation method of supernova neutrino detection on Earth is applied to some other spallation neutron sources, and the total expected numbers of supernova neutrinos observed through different reactions channels are given. Supported by National Natural Science Foundation of China (11205185, 11175020, 11275025, 11575023)

  9. Nuisance Source Population Modeling for Radiation Detection System Analysis

    Sokkappa, P; Lange, D; Nelson, K; Wheeler, R

    2009-10-05

    A major challenge facing the prospective deployment of radiation detection systems for homeland security applications is the discrimination of radiological or nuclear 'threat sources' from radioactive, but benign, 'nuisance sources'. Common examples of such nuisance sources include naturally occurring radioactive material (NORM), medical patients who have received radioactive drugs for either diagnostics or treatment, and industrial sources. A sensitive detector that cannot distinguish between 'threat' and 'benign' classes will generate false positives which, if sufficiently frequent, will preclude it from being operationally deployed. In this report, we describe a first-principles physics-based modeling approach that is used to approximate the physical properties and corresponding gamma ray spectral signatures of real nuisance sources. Specific models are proposed for the three nuisance source classes - NORM, medical and industrial. The models can be validated against measured data - that is, energy spectra generated with the model can be compared to actual nuisance source data. We show by example how this is done for NORM and medical sources, using data sets obtained from spectroscopic detector deployments for cargo container screening and urban area traffic screening, respectively. In addition to capturing the range of radioactive signatures of individual nuisance sources, a nuisance source population model must generate sources with a frequency of occurrence consistent with that found in actual movement of goods and people. Measured radiation detection data can indicate these frequencies, but, at present, such data are available only for a very limited set of locations and time periods. In this report, we make more general estimates of frequencies for NORM and medical sources using a range of data sources such as shipping manifests and medical treatment statistics. We also identify potential data sources for industrial

  10. Verification of Minimum Detectable Activity for Radiological Threat Source Search

    Gardiner, Hannah; Myjak, Mitchell; Baciak, James; Detwiler, Rebecca; Seifert, Carolyn

    2015-10-01

    The Department of Homeland Security's Domestic Nuclear Detection Office is working to develop advanced technologies that will improve the ability to detect, localize, and identify radiological and nuclear sources from airborne platforms. The Airborne Radiological Enhanced-sensor System (ARES) program is developing advanced data fusion algorithms for analyzing data from a helicopter-mounted radiation detector. This detector platform provides a rapid, wide-area assessment of radiological conditions at ground level. The NSCRAD (Nuisance-rejection Spectral Comparison Ratios for Anomaly Detection) algorithm was developed to distinguish low-count sources of interest from benign naturally occurring radiation and irrelevant nuisance sources. It uses a number of broad, overlapping regions of interest to statistically compare each newly measured spectrum with the current estimate for the background to identify anomalies. We recently developed a method to estimate the minimum detectable activity (MDA) of NSCRAD in real time. We present this method here and report on the MDA verification using both laboratory measurements and simulated injects on measured backgrounds at or near the detection limits. This work is supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-12-X-00376. This support does not constitute an express or implied endorsement on the part of the Gov't.

  11. Calculation of spatial distribution of the EURACOS II converter source

    Santo, A.C.F. de

    1985-01-01

    It is obtained the neutron spatial flux from the EURACOS (Enriched Uranium Converter Source) device, adjusted to experimental measures. The EURACOS device is a converter source which is constituted a circle plate of highly enriched uranium (90%). The converter provides an intense source of fast neutrons which has the energetic spectrum near to the fission spectrum. (M.C.K.) [pt

  12. Calibration experiments of neutron source identification and detection in soil

    Gorin, N. V.; Lipilina, E. N.; Rukavishnikov, G. V.; Shmakov, D. V.; Ulyanov, A. I.

    2007-01-01

    In the course of detection of fissile materials in soil, series of calibration experiments were carried out on in laboratory conditions on an experimental installation, presenting a mock-up of an endless soil with various heterogeneous bodies in it, fissile material, measuring boreholes. A design of detecting device, methods of neutrons detection are described. Conditions of neutron background measuring are given. Soil density, humidity, chemical composition of soil was measured. Sensitivity of methods of fissile materials detection and identification in soil was estimated in the calibration experiments. Minimal detectable activity and the distance at which it can be detected were defined. Characteristics of neutron radiation in a borehole mock-up were measured; dependences of method sensitivities from water content in soil, source-detector distance and presence of heterogeneous bodies were examined. Possibility of direction detection to a fissile material as neutron source from a borehole using a collimator is shown. Identification of fissile material was carried out by measuring the gamma-spectrum. Mathematical modeling was carried out using the PRIZMA code (Developed in RFNC-VNIITF) and MCNP code (Developed in LANL). Good correlation of calculational and experimental values was shown. The methodic were shown to be applicable in the field conditions

  13. Top-up operation at Pohang Light Source-II

    Hwang, I.; Huang, J. Y.; Kim, M.; Lee, B.-J.; Kim, C.; Choi, J.-Y.; Kim, M.-H.; Lee, H. S.; Moon, D.; Lee, E. H.; Kim, D.-E.; Nam, S. H.; Shin, S. [Pohang Accelerator Laboratory, Pohang, Kyungbuk 790-834 (Korea, Republic of); Cho, Moohyun [Department of Physics, POSTECH, Pohang, Kyungbuk 790-834 (Korea, Republic of)

    2014-05-15

    After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si ) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan.

  14. The new German neutron source FRM-II

    Nuding, M.

    2003-01-01

    The 'Technische Universitaet Muenchen' has built a new high-flux research reactor, the 'Forschungsreaktor Muenchen'-II. This new reactor will replace the 'Forschungsreaktor Muenchen' which has been operated very successfully for about 43 years. The 'Forschungsreaktor Muenchen'-II has been developed with first priority for beam-tube experiments, but it will also provide possibilities for irradiation experiments or isotope production. The reactor was designed to obtain a high and spectrally pure thermal neutron flux is available in a large volume outside of the core, where it is accessible for experimental use. In addition to beam-tubes which will end in the thermal neutron field there will be beam-tubes that will provide - with the help of 'spectrum shifters' -cold; hot and fast neutrons. Even through the thermal power of the 'Forschungsreaktor Muenchen'-II was limited to 20 MW an unperturbed maximum thermal neutron flux of about 8 x 10 14 cm -2 s -1 will be reached. Because of its 'compact-core-concept' the 'Forschungsreaktor Muenchen'-II will have the best flux-to-power-ratio worldwide: The fuel element and its highly enriched U 3 Si 2 -Al-fuel were tested during the licensing procedure of the 'Forschungsreaktor Muenchen'-II. Within the scope of this 'hydraulic test' the stability and the vibration behavior of the fuel plates as well as the long-tem behavior of the fuel element were investigated (Authors)

  15. Detection of aeroacoustic sound sources on aircraft and wind turbines

    Oerlemans, Stefan

    2009-01-01

    This thesis deals with the detection of aeroacoustic sound sources on aircraft and wind turbines using phased microphone arrays. First, the reliability of the array technique is assessed using airframe noise measurements in open and closed wind tunnels. It is demonstrated that quantitative acoustic

  16. Plagiarism Detection Algorithm for Source Code in Computer Science Education

    Liu, Xin; Xu, Chan; Ouyang, Boyu

    2015-01-01

    Nowadays, computer programming is getting more necessary in the course of program design in college education. However, the trick of plagiarizing plus a little modification exists among some students' home works. It's not easy for teachers to judge if there's plagiarizing in source code or not. Traditional detection algorithms cannot fit this…

  17. Geometric effects in alpha particle detection from distributed air sources

    Gil, L.R.; Leitao, R.M.S.; Marques, A.; Rivera, A.

    1994-08-01

    Geometric effects associated to detection of alpha particles from distributed air sources, as it happens in Radon and Thoron measurements, are revisited. The volume outside which no alpha particle may reach the entrance window of the detector is defined and determined analytically for rectangular and cylindrical symmetry geometries. (author). 3 figs

  18. Complex Event Detection via Multi Source Video Attributes (Open Access)

    2013-10-03

    Complex Event Detection via Multi-Source Video Attributes Zhigang Ma† Yi Yang‡ Zhongwen Xu‡§ Shuicheng Yan Nicu Sebe† Alexander G. Hauptmann...under its International Research Centre @ Singapore Fund- ing Initiative and administered by the IDM Programme Of- fice, and the Intelligence Advanced

  19. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  20. The new German neutron source FRM-II

    Nuding, M.; Axmann, A.; Boening, K.

    2002-01-01

    The construction of a new high-flux research reactor, the FRM-II is finished. This new reactor shall replace the existing FRM, which has been operated very successfully for about 43 years. The report at first presents the main applications of the FRM-II and its core and plant design. After that a description of the tests performed during the licensing procedure is given. At the end some current topics are discussed and an outlook on the time schedule is presented [ru

  1. Passive Detection of Narrowband Sources Using a Sensor Array

    Chambers, D H; Candy, J V; Guidry, B L

    2007-10-24

    In this report we derive a model for a highly scattering medium, implemented as a set of MATLAB functions. This model is used to analyze an approach for using time-reversal to enhance the detection of a single frequency source in a highly scattering medium. The basic approach is to apply the singular value decomposition to the multistatic response matrix for a time-reversal array system. We then use the array in a purely passive mode, measuring the response to the presence of a source. The measured response is projected onto the singular vectors, creating a time-reversal pseudo-spectrum. We can then apply standard detection techniques to the pseudo-spectrum to determine the presence of a source. If the source is close to a particular scatterer in the medium, then we would expect an enhancement of the inner product between the array response to the source with the singular vector associated with that scatterer. In this note we begin by deriving the Foldy-Lax model of a highly scattering medium, calculate both the field emitted by the source and the multistatic response matrix of a time-reversal array system in the medium, then describe the initial analysis approach.

  2. Detecting people of interest from internet data sources

    Cardillo, Raymond A.; Salerno, John J.

    2006-04-01

    In previous papers, we have documented success in determining the key people of interest from a large corpus of real-world evidence. Our recent efforts focus on exploring additional domains and data sources. Internet data sources such as email, web pages, and news feeds make it easier to gather a large corpus of documents for various domains, but detecting people of interest in these sources introduces new challenges. Analyzing these massive sources magnifies entity resolution problems, and demands a storage management strategy that supports efficient algorithmic analysis and visualization techniques. This paper discusses the techniques we used in order to analyze the ENRON email repository, which are also applicable to analyzing web pages returned from our "Buddy" meta-search engine.

  3. An overview of gravitational waves theory, sources and detection

    Auger, Gerard

    2017-01-01

    This book describes detection techniques used to search for and analyze gravitational waves (GW). It covers the whole domain of GW science, starting from the theory and ending with the experimental techniques (both present and future) used to detect them. The theoretical sections of the book address the theory of general relativity and of GW, followed by the theory of GW detection. The various sources of GW are described as well as the methods used to analyse them and to extract their physical parameters. It includes an analysis of the consequences of GW observations in terms of astrophysics as well as a description of the different detectors that exist and that are planned for the future. With the recent announcement of GW detection and the first results from LISA Pathfinder, this book will allow non-specialists to understand the present status of the field and the future of gravitational wave science

  4. A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  5. LEVIS ion source and beam characterization on PBFA-II

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Bailey, J.E.; Filuk, A.B.; Johnson, D.J.; Pointon, T.D.

    1993-01-01

    We report on the continuing development of the LEVIS (Laser Evaporation Ion Source) lithium active ion source for the 15-cm radial focussing ion diode on PBFA-11. We found previously that DC-heating of the anode surface to 150 degrees C maximum for 5 hours resulted in a pure lithium beam. This paper discusses the characterization of LEVIS source uniformity by Faraday cup arrays and multiple lines of sight for visible light spectroscopy. These diagnostics give some evidence of nonuniformity in both A-K gap electric fields and ion current density. Despite this, however, the measured focal spot size appears smaller than with a passive LiF source operated in the same magnetic field topology. Experiments using a curved anode for vertical beam focussing show reduced ion beam turn-on delay by 5 ns by altering the magnetic field topology as well as anode curvature. Another 3--5 ns reduction was achieved by switching from a passive LiF to the active LEVIS source

  6. Finding joy in social work. II: Intrapersonal sources.

    Pooler, David Kenneth; Wolfer, Terry; Freeman, Miriam

    2014-07-01

    Despite the social work profession's strengths orientation, research on its workforce tends to focus on problems (for example, depression, problem drinking, compassion fatigue, burnout). In contrast, this study explored ways in which social workers find joy in their work. The authors used an appreciative inquiry approach, semistructured interviews (N = 26), and a collaborative grounded theory method of analysis. Participants identified interpersonal (making connections and making a difference) and intrapersonal (making meaning and making a life) sources of joy and reflected significant personal initiative in the process of finding joy. The authors present findings regarding these intrapersonal sources of joy.

  7. Accelerating fissile material detection with a neutron source

    Rowland, Mark S.; Snyderman, Neal J.

    2018-01-30

    A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

  8. A Comparison of Source Code Plagiarism Detection Engines

    Lancaster, Thomas; Culwin, Fintan

    2004-06-01

    Automated techniques for finding plagiarism in student source code submissions have been in use for over 20 years and there are many available engines and services. This paper reviews the literature on the major modern detection engines, providing a comparison of them based upon the metrics and techniques they deploy. Generally the most common and effective techniques are seen to involve tokenising student submissions then searching pairs of submissions for long common substrings, an example of what is defined to be a paired structural metric. Computing academics are recommended to use one of the two Web-based detection engines, MOSS and JPlag. It is shown that whilst detection is well established there are still places where further research would be useful, particularly where visual support of the investigation process is possible.

  9. 238Pu sources for cardiac pacemakers. II. Control

    Pottier, R.; Merigot, S.

    1976-01-01

    The method and the apparatus used for thermal (power) and radioactive control of radioisotopic sources for pacemakers are briefly described. The cybernetic system is also presented, which assumes almost automatically the monitoring of control, mechanical and electronic works, data processing, the measurements and computations, and the works related to quality control [fr

  10. Galactic Sources Detected in the NuSTAR Serendipitous Survey

    Tomsick, John A.; Clavel, Maïca; Chiu, Jeng-Lun [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450 (United States); Lansbury, George B.; Aird, James [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Rahoui, Farid [Department of Astronomy, Harvard University, 60 Garden Street, Cambridge, MA 02138 (United States); Fornasini, Francesca M.; Hong, JaeSub; Grindlay, Jonathan E. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Alexander, David M. [Centre for Extragalactic Astronomy, Department of Physics, University of Durham, South Road, Durham DH1 3LE (United Kingdom); Bodaghee, Arash [Georgia College and State University, Milledgeville, GA 31061 (United States); Hailey, Charles J.; Mori, Kaya [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Harrison, Fiona A. [California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Krivonos, Roman A. [Space Research Institute of the Russian Academy of Sciences, Profsoyuznaya Str. 84/32, 117997, Moscow (Russian Federation); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States)

    2017-06-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) provides an improvement in sensitivity at energies above 10 keV by two orders of magnitude over non-focusing satellites, making it possible to probe deeper into the Galaxy and universe. Lansbury and collaborators recently completed a catalog of 497 sources serendipitously detected in the 3–24 keV band using 13 deg{sup 2} of NuSTAR coverage. Here, we report on an optical and X-ray study of 16 Galactic sources in the catalog. We identify 8 of them as stars (but some or all could have binary companions), and use information from Gaia to report distances and X-ray luminosities for 3 of them. There are 4 CVs or CV candidates, and we argue that NuSTAR J233426–2343.9 is a relatively strong CV candidate based partly on an X-ray spectrum from XMM-Newton . NuSTAR J092418–3142.2, which is the brightest serendipitous source in the Lansbury catalog, and NuSTAR J073959–3147.8 are low-mass X-ray binary candidates, but it is also possible that these 2 sources are CVs. One of the sources is a known high-mass X-ray binary (HMXB), and NuSTAR J105008–5958.8 is a new HMXB candidate that has strong Balmer emission lines in its optical spectrum and a hard X-ray spectrum. We discuss the implications of finding these HMXBs for the surface density (log N –log S ) and luminosity function of Galactic HMXBs. We conclude that with the large fraction of unclassified sources in the Galactic plane detected by NuSTAR in the 8–24 keV band, there could be a significant population of low-luminosity HMXBs.

  11. Outer heliospheric radio emissions. II - Foreshock source models

    Cairns, Iver H.; Kurth, William S.; Gurnett, Donald A.

    1992-01-01

    Observations of LF radio emissions in the range 2-3 kHz by the Voyager spacecraft during the intervals 1983-1987 and 1989 to the present while at heliocentric distances greater than 11 AU are reported. New analyses of the wave data are presented, and the characteristics of the radiation are reviewed and discussed. Two classes of events are distinguished: transient events with varying starting frequencies that drift upward in frequency and a relatively continuous component that remains near 2 kHz. Evidence for multiple transient sources and for extension of the 2-kHz component above the 2.4-kHz interference signal is presented. The transient emissions are interpreted in terms of radiation generated at multiples of the plasma frequency when solar wind density enhancements enter one or more regions of a foreshock sunward of the inner heliospheric shock. Solar wind density enhancements by factors of 4-10 are observed. Propagation effects, the number of radiation sources, and the time variability, frequency drift, and varying starting frequencies of the transient events are discussed in terms of foreshock sources.

  12. Some statistical problems inherent in radioactive-source detection

    Barnett, C.S.

    1978-01-01

    Some of the statistical questions associated with problems of detecting random-point-process signals embedded in random-point-process noise are examined. An example of such a problem is that of searching for a lost radioactive source with a moving detection system. The emphasis is on theoretical questions, but some experimental and Monte Carlo results are used to test the theoretical results. Several idealized binary decision problems are treated by starting with simple, specific situations and progressing toward more general problems. This sequence of decision problems culminates in the minimum-cost-expectation rule for deciding between two Poisson processes with arbitrary intensity functions. As an example, this rule is then specialized to the detector-passing-a-point-source decision problem. Finally, Monte Carlo techniques are used to develop and test one estimation procedure: the maximum-likelihood estimation of a parameter in the intensity function of a Poisson process. For the Monte Carlo test this estimation procedure is specialized to the detector-passing-a-point-source case. Introductory material from probability theory is included so as to make the report accessible to those not especially conversant with probabilistic concepts and methods. 16 figures

  13. Hydrocyanation of sulfonylimines using potassium hexacyanoferrate(II) as an eco-friendly cyanide source

    Li, Zheng; Li, Rongzhi; Zheng, Huanhuan; Wen, Fei; Li, Hongbo; Yin, Junjun; Yang, Jingya

    2013-01-01

    An efficient and eco-friendly method for hydrocyanation of sulfonylimines via one-pot two-step procedure using potassium hexacyanoferrate)II) as cyanide source, benzoyl chloride as a promoter, and potassium carbonate as a base is described. This protocol has the features of using nontoxic, nonvolatile and inexpensive cyanide source, high yield, and simple work-up procedure. (author)

  14. Hydrocyanation of sulfonylimines using potassium hexacyanoferrate(II) as an eco-friendly cyanide source

    Li, Zheng; Li, Rongzhi; Zheng, Huanhuan; Wen, Fei; Li, Hongbo; Yin, Junjun; Yang, Jingya, E-mail: lizheng@nwnu.edu.cn [Key Laboratory of Eco-Environment-Related Polymer Materials for Ministry of Education, College of Chemistry and Chemical Engineering, Northwest Normal University, Gansu (China)

    2013-11-15

    An efficient and eco-friendly method for hydrocyanation of sulfonylimines via one-pot two-step procedure using potassium hexacyanoferrate)II) as cyanide source, benzoyl chloride as a promoter, and potassium carbonate as a base is described. This protocol has the features of using nontoxic, nonvolatile and inexpensive cyanide source, high yield, and simple work-up procedure. (author)

  15. General-purpose heat source development. Phase II: conceptual designs

    Snow, E.C.; Zocher, R.W.; Grinberg, I.M.; Hulbert, L.E.

    1978-11-01

    Basic geometric module shapes and fuel arrays were studied to determine how well they could be expected to meet the General Purpose Heat Source (GPHS) design requirements. Seven conceptual designs were selected, detailed drawings produced, and these seven concepts analyzed. Three of these design concepts were selected as GPHS Trial Designs to be reanalyzed in more detail and tested. The geometric studies leading to the selection of the seven conceptual designs, the analyses of these designs, and the selection of the three trial designs are discussed

  16. Intelligent Flamefinder Detection and Alert System (IFDAS), Phase II

    National Aeronautics and Space Administration — Current hydrogen flame detection systems exhibit shortcomings ranging from limited detection range, to localization inaccuracy, limited sensitivity, false alarms,...

  17. VizieR Online Data Catalog: ROSAT detected quasars. II. (Yuan+ 1998)

    Yuan, W.; Brinkmann, W.; Siebert, J.; Voges, W.

    1997-11-01

    We have compiled a sample of all radio-quiet quasars or quasars without radio detection from the Veron-Cetty - Veron catalogue (1993, VV93, Cat. ) detected by ROSAT in the ALL-SKY SURVEY (RASS, Voges 1992, in Proc. of the ISY Conference `Space Science', ESA ISY-3, ESA Publications, p.9, See Cat. ), as targets of pointed observations, or as serendipitous sources from pointed observations publicly available from the ROSAT point source catalogue (ROSAT-SRC, Voges et al. 1995, Cat. ). For all sources we used the results of the Standard Analysis Software System (SASS, Voges et al. 1992, in Proc. of the ISY Conference `Space Science', ESA ISY-3, ESA Publications, p.223), employing the most recent processing for the Survey data (RASS-II, Voges et al. 1996, Cat. ). The total number of quasars is 846. 69 of the radio-quiet objects with radio detections have already been presented in a previous paper (Brinkmann, Yuan, & Siebert 1997, Cat. ) using the RASS-I results. 17 objects were found to be radio-loud from recent radio surveys and were marked in the table. When available, the power law photon indices and the corresponding absorption column densities (NH) were estimated from the two hardness ratios given by the SASS, both with free fitted NH and for Galactic absorption. The unabsorbed X-ray flux densities in the ROSAT band (0.1-2.4keV) were calculated from the count rates using the energy to counts conversion factor for power law spectra and Galactic absorption. As the photon index we used the value obtained for the individual source if the estimated 1-σ error is smaller than 0.5, otherwise we used the redshift-dependent mean value (see the paper for details). (1 data file).

  18. Dietary Sources of High Sodium Intake in Turkey: SALTURK II

    Yunus Erdem

    2017-08-01

    Full Text Available Previous research has shown daily salt intakes in Turkey to be far above the recommended limits. Knowing the sources of dietary salt could form a basis for preventive strategies aimed towards salt reduction. This study aimed to investigate dietary sources of salt in Turkey. A sub-group (n = 657 was selected from the PatenT2 study population, which represented the urban and rural areas of 4 major cities (Ankara, Istanbul, Izmir, and Konya. A questionnaire inquiring about sociodemographic characteristics, medical histories, detailed histories of diet, and salt consumption was completed. Participants were asked to collect a 24-h urine sample and to record their food intake (dietary recall on the same day. Of 925 participants selected, 657 (71% provided accurate 24-h urine collections, based on creatinine excretion data. The mean daily 24-h urinary sodium excretion was 252.0 ± 92.2 mmol/day, equal to daily salt intake of 14.8 ± 5.4 g. Of the 657 participants with accurate 24-h urine collections, 464 (70% provided fully completed dietary recalls. Among these 464 participants, there was a significant difference between the 24-h urinary sodium excretion-based salt intake estimation (14.5 ± 5.1 g/day and the dietary recall-based salt intake estimation (12.0 ± 7.0 g/day (p < 0.001. On the other hand, a positive correlation was obtained between the dietary recall-based daily salt intake and 24-h urinary sodium excretion-based daily salt intake (r = 0.277, p < 0.001. Bread was the main source of salt (34% followed by salt added during cooking and preparing food before serving (30%, salt from various processed foods (21%, and salt added at the table during food consumption (11%. Conclusively, this study confirmed a very high salt intake of the adult population in four major cities in Turkey. The present findings support the emerging salt reduction strategy in Turkey by promoting lower salt content in baked bread, and less salt use in habitual food

  19. Magnetoencephalographic accuracy profiles for the detection of auditory pathway sources.

    Bauer, Martin; Trahms, Lutz; Sander, Tilmann

    2015-04-01

    The detection limits for cortical and brain stem sources associated with the auditory pathway are examined in order to analyse brain responses at the limits of the audible frequency range. The results obtained from this study are also relevant to other issues of auditory brain research. A complementary approach consisting of recordings of magnetoencephalographic (MEG) data and simulations of magnetic field distributions is presented in this work. A biomagnetic phantom consisting of a spherical volume filled with a saline solution and four current dipoles is built. The magnetic fields outside of the phantom generated by the current dipoles are then measured for a range of applied electric dipole moments with a planar multichannel SQUID magnetometer device and a helmet MEG gradiometer device. The inclusion of a magnetometer system is expected to be more sensitive to brain stem sources compared with a gradiometer system. The same electrical and geometrical configuration is simulated in a forward calculation. From both the measured and the simulated data, the dipole positions are estimated using an inverse calculation. Results are obtained for the reconstruction accuracy as a function of applied electric dipole moment and depth of the current dipole. We found that both systems can localize cortical and subcortical sources at physiological dipole strength even for brain stem sources. Further, we found that a planar magnetometer system is more suitable if the position of the brain source can be restricted in a limited region of the brain. If this is not the case, a helmet-shaped sensor system offers more accurate source estimation.

  20. FEASIBILITY STUDY II OF A MUON BASED NEUTRINO SOURCE.

    GALLARDO,J.C.; OZAKI,S.; PALMER,R.B.; ZISMAN,M.

    2001-06-30

    The concept of using a muon storage ring to provide a well characterized beam of muon and electron neutrinos (a Neutrino Factory) has been under study for a number of years now at various laboratories throughout the world. The physics program of a Neutrino Factoryis focused on the relatively unexplored neutrino sector. In conjunction with a detector located a suitable distance from the neutrino source, the facility would make valuable contributions to the study of neutrino masses and lepton mixing. A Neutrino Factory is expected to improve the measurement accuracy of sin{sup 2}(2{theta}{sub 23}) and {Delta}m{sup 2}{sub 32} and provide measurements of sin{sup 2}(2{theta}{sub 13}) and the sign of {Delta}m{sup 2}{sub 32}. It may also be able to measure CP violation in the lepton sector.

  1. Stochastic Industrial Source Detection Using Lower Cost Methods

    Thoma, E.; George, I. J.; Brantley, H.; Deshmukh, P.; Cansler, J.; Tang, W.

    2017-12-01

    Hazardous air pollutants (HAPs) can be emitted from a variety of sources in industrial facilities, energy production, and commercial operations. Stochastic industrial sources (SISs) represent a subcategory of emissions from fugitive leaks, variable area sources, malfunctioning processes, and improperly controlled operations. From the shared perspective of industries and communities, cost-effective detection of mitigable SIS emissions can yield benefits such as safer working environments, cost saving through reduced product loss, lower air shed pollutant impacts, and improved transparency and community relations. Methods for SIS detection can be categorized by their spatial regime of operation, ranging from component-level inspection to high-sensitivity kilometer scale surveys. Methods can be temporally intensive (providing snap-shot measures) or sustained in both time-integrated and continuous forms. Each method category has demonstrated utility, however, broad adoption (or routine use) has thus far been limited by cost and implementation viability. Described here are a subset of SIS methods explored by the U.S EPA's next generation emission measurement (NGEM) program that focus on lower cost methods and models. An emerging systems approach that combines multiple forms to help compensate for reduced performance factors of lower cost systems is discussed. A case study of a multi-day HAP emission event observed by a combination of low cost sensors, open-path spectroscopy, and passive samplers is detailed. Early field results of a novel field gas chromatograph coupled with a fast HAP concentration sensor is described. Progress toward near real-time inverse source triangulation assisted by pre-modeled facility profiles using the Los Alamos Quick Urban & Industrial Complex (QUIC) model is discussed.

  2. FRM-II research neutron source commissioned; Eroeffnung der Forschungs-Neutronenquelle Heinz Maier-Leibnitz - FRM-II

    Anon.

    2004-07-01

    On March 2, 2004, the Heinz Maier-Leibnitz research neutron source (FRM-II) generated neutrons for the first time. This marked the most important step on the way to using FRM-II for scientific purposes. On this occasion, this unique research facility in the world was dedicated in a ceremony attended by approximately 1000 representatives of politics, industry, and science. The keynote speaker, Federal Minister of the Interior Otto Schily; Bavarian Minister President Edmund Stoiber; Professor Claus Weyrich (Member of the Executive Board of Siemens AG); Dr. Thomas Goppel (Bavarian State Minister for Science, Research, and Arts); Professor Wolfgang A. Herman (President of the Technical University of Munich); Hannelore Gabor (2nd Mayor of the host municipality of Garching); and Professor Winfried Petry (Scientific Director of FRM-II) underlined the great importance of FRM-II for science, research, medicine, and technology. FRM-II will not only fill the 'neutron gap', but create extremely brilliant working conditions thanks to its considerably higher neutron flux compared to that of its predecessor, the legendary Atomic Egg. After the first conceptual design studies starting in 1980, the ground breaking ceremony in August 1996, and the third partial permit issued at Easter of 2003, a unique tool is now available for modern science and for medical and technical applications. (orig.) [German] Am 2. Maerz 2004 hat die Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM-II) erstmals Neutronen erzeugt. Damit war der wichtigste Schritt erreicht, der den Weg zur wissenschaftlichen Nutzung des FRM-II einleitet. Aus diesem Anlass wurde unter Teilnahme von rund 1 000 Vertretern aus Politik, Wirtschaft und Wissenschaft diese weltweit einmalige Forschungseinrichtung eroeffnet und ihrer Bestimmung uebergeben. Die Festredner, Bundesinnenminister Otto Schily, der bayerische Ministerpraesident Edmund Stoiber, Professor Claus Weyrich (Mitglied des Vorstands der Siemens AG), Dr

  3. Detection, Source Location, and Analysis of Volcano Infrasound

    McKee, Kathleen F.

    The study of volcano infrasound focuses on low frequency sound from volcanoes, how volcanic processes produce it, and the path it travels from the source to our receivers. In this dissertation we focus on detecting, locating, and analyzing infrasound from a number of different volcanoes using a variety of analysis techniques. These works will help inform future volcano monitoring using infrasound with respect to infrasonic source location, signal characterization, volatile flux estimation, and back-azimuth to source determination. Source location is an important component of the study of volcano infrasound and in its application to volcano monitoring. Semblance is a forward grid search technique and common source location method in infrasound studies as well as seismology. We evaluated the effectiveness of semblance in the presence of significant topographic features for explosions of Sakurajima Volcano, Japan, while taking into account temperature and wind variations. We show that topographic obstacles at Sakurajima cause a semblance source location offset of 360-420 m to the northeast of the actual source location. In addition, we found despite the consistent offset in source location semblance can still be a useful tool for determining periods of volcanic activity. Infrasonic signal characterization follows signal detection and source location in volcano monitoring in that it informs us of the type of volcanic activity detected. In large volcanic eruptions the lowermost portion of the eruption column is momentum-driven and termed the volcanic jet or gas-thrust zone. This turbulent fluid-flow perturbs the atmosphere and produces a sound similar to that of jet and rocket engines, known as jet noise. We deployed an array of infrasound sensors near an accessible, less hazardous, fumarolic jet at Aso Volcano, Japan as an analogue to large, violent volcanic eruption jets. We recorded volcanic jet noise at 57.6° from vertical, a recording angle not normally feasible

  4. Detecting analogical resemblance without retrieving the source analogy.

    Kostic, Bogdan; Cleary, Anne M; Severin, Kaye; Miller, Samuel W

    2010-06-01

    We examined whether people can detect analogical resemblance to an earlier experimental episode without being able to recall the experimental source of the analogical resemblance. We used four-word analogies (e.g., robin-nest/beaver-dam), in a variation of the recognition-without-cued-recall method (Cleary, 2004). Participants studied word pairs (e.g., robin-nest) and were shown new word pairs at test, half of which analogically related to studied word pairs (e.g., beaver-dam) and half of which did not. For each test pair, participants first attempted to recall an analogically similar pair from the study list. Then, regardless of whether successful recall occurred, participants were prompted to rate the familiarity of the test pair, which was said to indicate the likelihood that a pair that was analogically similar to the test pair had been studied. Across three experiments, participants demonstrated an ability to detect analogical resemblance without recalling the source analogy. Findings are discussed in terms of their potential relevance to the study of analogical reasoning and insight, as well as to the study of familiarity and recognition memory.

  5. Confrontation of the Magnetically Arrested Disc Scenario with Observations of FR II Sources

    Rusinek, Katarzyna; Sikora, Marek, E-mail: krusinek@camk.edu.pl [Nicolaus Copernicus Astronomical Center, Polish Academy of Sciences, Warsaw (Poland)

    2017-10-12

    The main aim of our work was to check whether powers of jets in FR II radio galaxies (RGs) and quasars (QSOs) can be reproduced by the Magnetically Arrested Disc (MAD) scenario. Assuming that established in the recent numerical simulations of the MAD scenario the (H/R){sup 2} dependence of the jet production efficiency is correct, we demonstrate that in order to reproduce the observed jet powers in FR II sources: (i) accretion discs must be geometrically much thicker than the standard ones; (ii) and/or that the jet production is strongly modulated.

  6. Detection of aeroacoustic sound sources on aircraft and wind turbines

    Oerlemans, S.

    2009-01-01

    This thesis deals with the detection of aeroacoustic sound sources on aircraft and wind turbines using phased microphone arrays. First, the reliability of the array technique is assessed using airframe noise measurements in open and closed wind tunnels. It is demonstrated that quantitative acoustic measurements are possible in both wind tunnels. Then, the array technique is applied to characterize the noise sources on two modern large wind turbines. It is shown that practically all noise emitted to the ground is produced by the outer part of the blades during their downward movement. This asymmetric source pattern, which causes the typical swishing noise during the passage of the blades, can be explained by trailing edge noise directivity and convective amplification. Next, a semi-empirical prediction method is developed for the noise from large wind turbines. The prediction code is successfully validated against the experimental results, not only with regard to sound levels, spectra, and directivity, but also with regard to the noise source distribution in the rotor plane and the temporal variation in sound level (swish). The validated prediction method is then applied to calculate wind turbine noise footprints, which show that large swish amplitudes can occur even at large distance. The influence of airfoil shape on blade noise is investigated through acoustic wind tunnel tests on a series of wind turbine airfoils. Measurements are carried out at various wind speeds and angles of attack, with and without upstream turbulence and boundary layer tripping. The speed dependence, directivity, and tonal behaviour are determined for both trailing edge noise and inflow turbulence noise. Finally, two noise reduction concepts are tested on a large wind turbine: acoustically optimized airfoils and trailing edge serrations. Both blade modifications yield a significant trailing edge noise reduction at low frequencies, but also cause increased tip noise at high frequencies

  7. The Bologna complete sample of nearby radio sources. II. Phase referenced observations of faint nuclear sources

    Liuzzo, E.; Giovannini, G.; Giroletti, M.; Taylor, G. B.

    2009-10-01

    Aims: To study statistical properties of different classes of sources, it is necessary to observe a sample that is free of selection effects. To do this, we initiated a project to observe a complete sample of radio galaxies selected from the B2 Catalogue of Radio Sources and the Third Cambridge Revised Catalogue (3CR), with no selection constraint on the nuclear properties. We named this sample “the Bologna Complete Sample” (BCS). Methods: We present new VLBI observations at 5 and 1.6 GHz for 33 sources drawn from a sample not biased toward orientation. By combining these data with those in the literature, information on the parsec-scale morphology is available for a total of 76 of 94 radio sources with a range in radio power and kiloparsec-scale morphologies. Results: The fraction of two-sided sources at milliarcsecond resolution is high (30%), compared to the fraction found in VLBI surveys selected at centimeter wavelengths, as expected from the predictions of unified models. The parsec-scale jets are generally found to be straight and to line up with the kiloparsec-scale jets. A few peculiar sources are discussed in detail. Tables 1-4 are only available in electronic form at http://www.aanda.org

  8. The Bipolar II Depression Questionnaire: A Self-Report Tool for Detecting Bipolar II Depression.

    Chi Ming Leung

    Full Text Available Bipolar II (BP-II depression is often misdiagnosed as unipolar (UP depression, resulting in suboptimal treatment. Tools for differentiating between these two types of depression are lacking. This study aimed to develop a simple, self-report screening instrument to help distinguish BP-II depression from UP depressive disorder. A prototype BP-II depression questionnaire (BPIIDQ-P was constructed following a literature review, panel discussions and a field trial. Consecutively assessed patients with a diagnosis of depressive disorder or BP with depressive episodes completed the BPIIDQ-P at a psychiatric outpatient clinic in Hong Kong between October and December 2013. Data were analyzed using discriminant analysis and logistic regression. Of the 298 subjects recruited, 65 (21.8% were males and 233 (78.2% females. There were 112 (37.6% subjects with BP depression [BP-I = 42 (14.1%, BP-II = 70 (23.5%] and 182 (62.4% with UP depression. Based on family history, age at onset, postpartum depression, episodic course, attacks of anxiety, hypersomnia, social phobia and agoraphobia, the 8-item BPIIDQ-8 was constructed. The BPIIDQ-8 differentiated subjects with BP-II from those with UP depression with a sensitivity/specificity of 0.75/0.63 for the whole sample and 0.77/0.72 for a female subgroup with a history of childbirth. The BPIIDQ-8 can differentiate BP-II from UP depression at the secondary care level with satisfactory to good reliability and validity. It has good potential as a screening tool for BP-II depression in primary care settings. Recall bias, the relatively small sample size, and the high proportion of females in the BP-II sample limit the generalization of the results.

  9. Chromatid Painting for Chromosomal Inversion Detection, Phase II

    National Aeronautics and Space Administration — We propose the continued development of a novel approach to the detection of chromosomal inversions. Transmissible chromosome aberrations (translocations and...

  10. CHANDRA OBSERVATIONS OF 3C RADIO SOURCES WITH z < 0.3. II. COMPLETING THE SNAPSHOT SURVEY

    Massaro, F. [SLAC National Laboratory and Kavli Institute for Particle Astrophysics and Cosmology, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Tremblay, G. R. [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching bei Muenchen (Germany); Harris, D. E.; O' Dea, C. P. [Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, MA 02138 (United States); Kharb, P.; Axon, D. [Department of Physics, Rochester Institute of Technology, Carlson Center for Imaging Science 76-3144, 84 Lomb Memorial Dr., Rochester, NY 14623 (United States); Balmaverde, B.; Capetti, A. [INAF-Osservatorio Astrofisico di Torino, Strada Osservatorio 20, I-10025 Pino Torinese (Italy); Baum, S. A. [Carlson Center for Imaging Science 76-3144, 84 Lomb Memorial Dr., Rochester, NY 14623 (United States); Chiaberge, M.; Macchetto, F. D.; Sparks, W. [Space Telescope Science Institute, 3700 San Martine Drive, Baltimore, MD 21218 (United States); Gilli, R. [INAF-Osservatorio Astronomico di Bologna, Via Ranzani 1, I-40127 Bologna (Italy); Giovannini, G. [INAF-Istituto di Radioastronomia di Bologna, Via Gobetti 101, I-40129 Bologna (Italy); Grandi, P.; Torresi, E. [INAF-IASF-Istituto di Astrofisica Spaziale e fisica Cosmica di Bologna, Via P. Gobetti 101, I-40129 Bologna (Italy); Risaliti, G. [INAF-Osservatorio Astronomico di Arcetri, Largo E. Fermi 5, I-50125 Firenze (Italy)

    2012-12-15

    We report on the second round of Chandra observations of the 3C snapshot survey developed to observe the complete sample of 3C radio sources with z < 0.3 for 8 ks each. In the first paper, we illustrated the basic data reduction and analysis procedures performed for the 30 sources of the 3C sample observed during Chandra Cycle 9, while here we present the data for the remaining 27 sources observed during Cycle 12. We measured the X-ray intensity of the nuclei and of any radio hot spots and jet features with associated X-ray emission. X-ray fluxes in three energy bands, i.e., soft, medium, and hard, for all the sources analyzed are also reported. For the stronger nuclei, we also applied the standard spectral analysis, which provides the best-fit values of the X-ray spectral index and absorbing column density. In addition, a detailed analysis of bright X-ray nuclei that could be affected by pile-up has been performed. X-ray emission was detected for all the nuclei of the radio sources in our sample except for 3C 319. Among the current sample, there are two compact steep spectrum radio sources, two broad-line radio galaxies, and one wide angle tail radio galaxy, 3C 89, hosted in a cluster of galaxies clearly visible in our Chandra snapshot observation. In addition, we also detected soft X-ray emission arising from the galaxy cluster surrounding 3C 196.1. Finally, X-ray emission from hot spots has been found in three FR II radio sources and, in the case of 3C 459, we also report the detection of X-ray emission associated with the eastern radio lobe as well as X-ray emission cospatial with radio jets in 3C 29 and 3C 402.

  11. Neutron activation analysis detection limits using 252Cf sources

    DiPrete, D.P.; Sigg, R.A.

    2000-01-01

    The Savannah River Technology Center (SRTC) developed a neutron activation analysis (NAA) facility several decades ago using low-flux 252 Cf neutron sources. Through this time, the facility has addressed areas of applied interest in managing the Savannah River Site (SRS). Some applications are unique because of the site's operating history and its chemical-processing facilities. Because sensitivity needs for many applications are not severe, they can be accomplished using an ∼6-mg 252 Cf NAA facility. The SRTC 252 Cf facility continues to support applied research programs at SRTC as well as other SRS programs for environmental and waste management customers. Samples analyzed by NAA include organic compounds, metal alloys, sediments, site process solutions, and many other materials. Numerous radiochemical analyses also rely on the facility for production of short-lived tracers, yielding by activation of carriers and small-scale isotope production for separation methods testing. These applications are more fully reviewed in Ref. 1. Although the flux [approximately2 x 10 7 n/cm 2 ·s] is low relative to reactor facilities, more than 40 elements can be detected at low and sub-part-per-million levels. Detection limits provided by the facility are adequate for many analytical projects. Other multielement analysis methods, particularly inductively coupled plasma atomic emission and inductively coupled plasma mass spectrometry, can now provide sensitivities on dissolved samples that are often better than those available by NAA using low-flux isotopic sources. Because NAA allows analysis of bulk samples, (a) it is a more cost-effective choice when its sensitivity is adequate than methods that require digestion and (b) it eliminates uncertainties that can be introduced by digestion processes

  12. Evaluation of the KEMRI Hep-cell II test kit for detection of hepatitis B ...

    To evaluate the Hep-cell II test, blood samples were collected from blood donors and processed for detection of HBsAg using Hep-cell II based on the test principle and procedure outlined by the manufacturer. ELISA Axsym HBsAg test was used as golden standard. Of the 400 samples tested, 287 (71.8%) were positive by ...

  13. Detection of environmental sources of Histoplasma capsulatum in Chiang Mai, Thailand, by nested PCR.

    Norkaew, Treepradab; Ohno, Hideaki; Sriburee, Pojana; Tanabe, Koichi; Tharavichitkul, Prasit; Takarn, Piyawan; Puengchan, Tanpalang; Bumrungsri, Sara; Miyazaki, Yoshitsugu

    2013-12-01

    Histoplasmosis is a systemic mycosis caused by inhaling spores of Histoplasma capsulatum, a dimorphic fungus. This fungus grows in soil contaminated with bat and avian excreta. Each year, patients with disseminated histoplasmosis have been diagnosed in Chiang Mai, northern Thailand. No published information is currently available on the environmental sources of this fungus in Chiang Mai or anywhere else in Thailand. The aim of this study was to detect H. capsulatum in soil samples contaminated with bat guano and avian droppings by nested PCR. Two hundred and sixty-five samples were collected from the following three sources: soil contaminated with bat guano, 88 samples; soil contaminated with bird droppings, 86 samples; and soil contaminated with chicken droppings, 91 samples. Genomic DNA was directly extracted from each sample, and H. capsulatum was detected by nested PCR using a primer set specific to a gene encoding 100-kDa-like protein (HcI, HcII and HcIII, HcIV). Histoplasma capsulatum was detected in seven of 88 soil samples contaminated with bat guano, one of 21 soil samples contaminated with pigeon droppings and 10 of 91 soil samples contaminated with chicken droppings. The results indicate the possibility of the association of bat guano and chicken droppings with H. capsulatum in this area of Thailand.

  14. Detection and quantitation of glutamate carboxypeptidase II in human blood

    Knedlík, Tomáš; Navrátil, Václav; Vik, V.; Pacík, D.; Šácha, Pavel; Konvalinka, Jan

    2014-01-01

    Roč. 74, č. 7 (2014), s. 768-780 ISSN 0270-4137 R&D Projects: GA ČR GAP304/12/0847 Grant - others:OPPC(CZ) CZ.2.16/3.1.00/24016 Institutional support: RVO:61388963 Keywords : serum marker * glutamate carboxypeptidase II * plasma glutamate carboxypeptidase * prostate cancer * prostate -specific membrane antigen Subject RIV: CE - Biochemistry Impact factor: 3.565, year: 2014

  15. Versatile Sensor for Transition, Separation, and Shock Detection, Phase II

    National Aeronautics and Space Administration — The proposed innovation is a simple, robust, self-contained, and self-powered sensor array for the detection of laminar/turbulent transition location, areas of...

  16. Rapid In-Place Composite Rotor Damage Detection, Phase II

    National Aeronautics and Space Administration — Luna Innovations is proposing to further develop the Rapid In-Place Composite Rotor Damage Detection (RIPCoRDD) System for determining and tracking the structural...

  17. Wormhole solutions sourced by fluids, II: three-fluid two-charged sources

    Azreg-Ainou, Mustapha [Baskent University, Faculty of Engineering, Ankara (Turkey)

    2016-01-15

    Lack of a consistent metric for generating rotating wormholes motivates us to present a new one endowed with interesting physical and geometrical properties. When combined with the generalized method of superposition of fields, which consists in attaching a form of matter to each moving frame, it generates massive and charged (charge without charge) two-fluid-sourced, massive and two-charged three-fluid-sourced, rotating as well as new static wormholes which, otherwise, can hardly be derived by integration. If the lapse function of the static wormhole is bounded from above, no closed timelike curves occur in the rotating counterpart. For positive energy densities dying out faster than 1/r, the angular velocity includes in its expansion a correction term, to the leading one that corresponds to ordinary stars, proportional to ln r/r{sup 4}. Such a term is not present in the corresponding expansion for the Kerr-Newman black hole. Based on this observation and our previous work, the dragging effects of falling neutral objects may constitute a substitute for other known techniques used for testing the nature of the rotating black hole candidates that are harbored in the center of galaxies. We discuss the possibility of generating (n + 1)-fluid-sourced, n-charged, rotating as well as static wormholes. (orig.)

  18. Wormhole solutions sourced by fluids, II: three-fluid two-charged sources

    Azreg-Aïnou, Mustapha, E-mail: azreg@baskent.edu.tr [Faculty of Engineering, Başkent University, Bağlıca Campus, 06810, Ankara (Turkey)

    2016-01-05

    Lack of a consistent metric for generating rotating wormholes motivates us to present a new one endowed with interesting physical and geometrical properties. When combined with the generalized method of superposition of fields, which consists in attaching a form of matter to each moving frame, it generates massive and charged (charge without charge) two-fluid-sourced, massive and two-charged three-fluid-sourced, rotating as well as new static wormholes which, otherwise, can hardly be derived by integration. If the lapse function of the static wormhole is bounded from above, no closed timelike curves occur in the rotating counterpart. For positive energy densities dying out faster than 1 / r, the angular velocity includes in its expansion a correction term, to the leading one that corresponds to ordinary stars, proportional to lnr/r{sup 4}. Such a term is not present in the corresponding expansion for the Kerr–Newman black hole. Based on this observation and our previous work, the dragging effects of falling neutral objects may constitute a substitute for other known techniques used for testing the nature of the rotating black hole candidates that are harbored in the center of galaxies. We discuss the possibility of generating (n+1)-fluid-sourced, n-charged, rotating as well as static wormholes.

  19. Turbulence in extended synchrotron radio sources. I. Polarization of turbulent sources. II. Power-spectral analysis

    Eilek, J.A.

    1989-01-01

    Recent theories of magnetohydrodynamic turbulence are used to construct microphysical turbulence models, with emphasis on models of anisotropic turbulence. These models have been applied to the determination of the emergent polarization from a resolved uniform source. It is found that depolarization alone is not a unique measure of the turbulence, and that the turblence will also affect the total-intensity distributions. Fluctuations in the intensity image can thus be employed to measure turbulence strength. In the second part, it is demonstrated that a power-spectral analysis of the total and polarized intensity images can be used to obtain the power spectra of the synchrotron emission. 81 refs

  20. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Gilson, E.P., E-mail: egilson@pppl.gov [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Davidson, R.C.; Efthimion, P.C.; Kaganovich, I.D. [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Kwan, J.W.; Lidia, S.M.; Ni, P.A.; Roy, P.K.; Seidl, P.A.; Waldron, W.L. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California, 94720 (United States); Barnard, J.J.; Friedman, A. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California, 94550 (United States)

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 10{sup 10} cm{sup −3} and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  1. EXTRASOLAR BINARY PLANETS. II. DETECTABILITY BY TRANSIT OBSERVATIONS

    Lewis, K. M.; Ida, S.; Ochiai, H.; Nagasawa, M.

    2015-01-01

    We discuss the detectability of gravitationally bound pairs of gas-giant planets (which we call “binary planets”) in extrasolar planetary systems that are formed through orbital instability followed by planet–planet dynamical tides during their close encounters, based on the results of N-body simulations by Ochiai et al. (Paper I). Paper I showed that the formation probability of a binary is as much as ∼10% for three giant planet systems that undergo orbital instability, and after post-capture long-term tidal evolution, the typical binary separation is three to five times the sum of the physical radii of the planets. The binary planets are stable during the main-sequence lifetime of solar-type stars, if the stellarcentric semimajor axis of the binary is larger than 0.3 AU. We show that detecting modulations of transit light curves is the most promising observational method to detect binary planets. Since the likely binary separations are comparable to the stellar diameter, the shape of the transit light curve is different from transit to transit, depending on the phase of the binary’s orbit. The transit durations and depth for binary planet transits are generally longer and deeper than those for the single planet case. We point out that binary planets could exist among the known inflated gas-giant planets or objects classified as false positive detections at orbital radii ≳0.3 AU, propose a binary planet explanation for the CoRoT candidate SRc01 E2 1066, and show that binary planets are likely to be present in, and could be detected using, Kepler-quality data

  2. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL

    2008-12-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.

  3. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.

    2008-01-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies

  4. Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX-II)

    Roy, P.K.; Greenway, W.; Kwan, J.W.; Seidl, P.A.; Waldron, W.

    2011-01-01

    To heat targets to electron-volt temperatures for the study of warm dense matter with intense ion beams, low mass ions, such as lithium, have an energy loss peak (dE/dx) at a suitable kinetic energy. The Heavy Ion Fusion Sciences (HIFS) program at Lawrence Berkeley National Laboratory will carry out warm dense matter experiments using Li + ion beam with energy 1.2-4 MeV in order to achieve uniform heating up to 0.1-1 eV. The accelerator physics design of Neutralized Drift Compression Experiment (NDCX-II) has a pulse length at the ion source of about 0.5 (micro)s. Thus for producing 50 nC of beam charge, the required beam current is about 100 mA. Focusability requires a normalized (edge) emittance ∼2 π-mm-mrad. Here, lithium aluminosilicate ion sources, of β-eucryptite, are being studied within the scope of NDCX-II construction. Several small (0.64 cm diameter) lithium aluminosilicate ion sources, on 70%-80% porous tungsten substrate, were operated in a pulsed mode. The distance between the source surface and the mid-plane of the extraction electrode (1 cm diameter aperture) was 1.48 cm. The source surface temperature was at 1220 C to 1300 C. A 5-6 (micro)s long beam pulsed was recorded by a Faraday cup (+300 V on the collector plate and -300 V on the suppressor ring). Figure 1 shows measured beam current density (J) vs. V 3/2 . A space-charge limited beam density of ∼1 mA/cm 2 was measured at 1275 C temperature, after allowing a conditioning time of about ∼ 12 hours. Maximum emission limited beam current density of (ge) 1.8mA/cm 2 was recorded at 1300 C with 10-kV extractions. Figure 2 shows the lifetime of two typical sources with space-charge limited beam current emission at a lower extraction voltage (1.75 kV) and at temperature of 1265 ± 7 C. These data demonstrate a constant, space-charge limited beam current for 20-50 hours. The lifetime of a source is determined by the loss of lithium from the alumino-silicate material either as ions or as neutral

  5. Getting to the Source: a Survey of Quantitative Data Sources Available to the Everyday Librarian: Part II: Data Sources from Specific Library Applications

    Lisa Goddard

    2007-03-01

    Full Text Available This is the second part of a two-part article that provides a survey of data sources which are likely to be immediately available to the typical practitioner who wishes to engage in statistical analysis of collections and services within his or her own library. Part I outlines the data elements which can be extracted from web server logs, and discusses web log analysis tools. Part II looks at logs, reports, and data sources from proxy servers, resource vendors, link resolvers, federated search engines, institutional repositories, electronic reference services, and the integrated library system.

  6. Detection of extended galactic sources with an underwater neutrino telescope

    Leisos, A.; Tsirigotis, A. G.; Tzamarias, S. E.; Lenis, D.

    2014-01-01

    In this study we investigate the discovery capability of a Very Large Volume Neutrino Telescope to Galactic extended sources. We focus on the brightest HESS gamma rays sources which are considered also as very high energy neutrino emitters. We use the unbinned method taking into account both the spatial and the energy distribution of high energy neutrinos and we investigate parts of the Galactic plane where nearby potential neutrino emitters form neutrino source clusters. Neutrino source clusters as well as isolated neutrino sources are combined to estimate the observation period for 5 sigma discovery of neutrino signals from these objects

  7. Highly sensitive detection of lead(II) ion using multicolor CdTe quantum dots

    Zhong, W.; Zhang, C.; Gao, Q.; Li, H.

    2012-01-01

    Multicolor and water-soluble CdTe quantum dots (QDs) were synthesized with thioglycolic acid (TGA) as stabilizer. These QDs have a good size distribution, display high fluorescence quantum yield, and can be applied to the ultrasensitive detection of Pb(II) ion by virtue of their quenching effect. The size of the QDs exerts a strong effect on sensitivity, and quenching of luminescence is most effective for the smallest particles. The quenching mechanism is discussed. Fairly selective detection was accomplished by utilizing QDs with a diameter of 1. 6 nm which resulted in a detection limit of 4. 7 nmol L -1 concentration of Pb(II). The method was successfully applied to the determination of Pb(II) in spinach and citrus leaves, and the results are in good agreement with those obtained with atomic absorption spectrometry. (author)

  8. A corrosion detection system for buried pipeline (II)

    Choi, Yoon Seok; Shin, Dong Ho; Kim, Sang Hyun; Kim, Jung Gu

    2005-01-01

    In order to develop a new corrosion sensor for detecting and monitoring the corrosion of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in synthetic groundwater, two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm), and synthetic tap water. In this paper, two types of electrochemical probes were used: galvanic cells containing of pipeline steel-copper and pipeline steel-stainless steel (Type 304). The results of EIS measurement indicated that the sensor current was inversely related to sensor resistance, which was governed by the corrosion behavior of cathode. In galvanic corrosion tests, the galvanic current of Cu-CS probe was higher than that of SS-CS probe. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. A good linear quantitative relationship was found between the Cu-CS probe current and the corrosion rate of pipeline steel coupons in the soil resistivity of 5,000 ohm-cm, and synthetic tap water. In the case of the soil resistivity of 10,000 ohm-cm, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe, due to the high current output

  9. Label free luminescence strategy for sensitive detection of ATP using aptamer-Ru(II) complexes

    Babu, Eththilu [Department of Physical Che mistry, School of Chemistry, Madurai Kamaraj University, Madurai 625021, Tamil Nadu (India); Muthu Mareeswaran, Paulpandian [Department of Physical Che mistry, School of Chemistry, Madurai Kamaraj University, Madurai 625021, Tamil Nadu (India); Department of Industrial Chemistry, Alagappa Univesity, Karaikudi 630003, Tamil Nadu (India); Ramdass, Arumugam [Department of Physical Che mistry, School of Chemistry, Madurai Kamaraj University, Madurai 625021, Tamil Nadu (India); Research Department of Chemistry, Aditanar College of Arts and Science, Tiruchendur 628216, Tamil Nadu (India); Ramesh, Pandian [UCIBIO-REQUIMTE, Departmento de Química, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica (Portugal); Rajagopal, Seenivasan, E-mail: rajagopalseenivasan@yahoo.com [Department of Physical Che mistry, School of Chemistry, Madurai Kamaraj University, Madurai 625021, Tamil Nadu (India)

    2016-07-15

    A simple and sensitive aptamer-based luminescence strategy for ATP detection is developed using Ru(II) complexes as probe molecule. It is based on the fact that Ru(II)-dppz complexes show the light switching behavior with DNA aptamers and found to show significant luminescence spectral change on the addition of ATP molecules. The binding efficiencies of aptamer with ATP, ADP and AMP are calculated and compared. The structural change of aptamer is also studied using circular dichroism (CD) spectral techniques. Moreover, the binding nature of aptamer with ATP, ADP and AMP is demonstrated by computational techniques. The proposed strategy was successfully applied to the detection of ATP.

  10. Label free luminescence strategy for sensitive detection of ATP using aptamer-Ru(II) complexes

    Babu, Eththilu; Muthu Mareeswaran, Paulpandian; Ramdass, Arumugam; Ramesh, Pandian; Rajagopal, Seenivasan

    2016-01-01

    A simple and sensitive aptamer-based luminescence strategy for ATP detection is developed using Ru(II) complexes as probe molecule. It is based on the fact that Ru(II)-dppz complexes show the light switching behavior with DNA aptamers and found to show significant luminescence spectral change on the addition of ATP molecules. The binding efficiencies of aptamer with ATP, ADP and AMP are calculated and compared. The structural change of aptamer is also studied using circular dichroism (CD) spectral techniques. Moreover, the binding nature of aptamer with ATP, ADP and AMP is demonstrated by computational techniques. The proposed strategy was successfully applied to the detection of ATP.

  11. Sources of long-lived atmospheric VOCs at the rural boreal forest site, SMEAR II

    Patokoski, J.; Ruuskanen, T. M.; Kajos, M. K.; Taipale, R.; Rantala, P.; Aalto, J.; Ryyppö, T.; Nieminen, T.; Hakola, H.; Rinne, J.

    2015-12-01

    In this study a long-term volatile organic compound (VOCs) concentration data set, measured at the SMEAR II (Station for Measuring Ecosystem-Atmosphere Relations) boreal forest site in Hyytiälä, Finland during the years 2006-2011, was analyzed in order to identify source areas and profiles of the observed VOCs. VOC mixing ratios were measured using proton transfer reaction mass spectrometry. Four-day HYSPLIT 4 (Hybrid Single Particle Lagrangian Integrated Trajectory) backward trajectories and the Unmix 6.0 receptor model were used for source area and source composition analysis. Two major forest fire events in Russia took place during the measurement period. The effect of these fires was clearly visible in the trajectory analysis, lending confidence to the method employed with this data set. Elevated volume mixing ratios (VMRs) of non-biogenic VOCs related to forest fires, e.g. acetonitrile and aromatic VOCs, were observed. Ten major source areas for long-lived VOCs (methanol, acetonitrile, acetaldehyde, acetone, benzene, and toluene) observed at the SMEAR II site were identified. The main source areas for all the targeted VOCs were western Russia, northern Poland, Kaliningrad, and the Baltic countries. Industrial areas in northern continental Europe were also found to be source areas for certain VOCs. Both trajectory and receptor analysis showed that air masses from northern Fennoscandia were less polluted with respect to both the VOCs studied and other trace gases (CO, SO2 and NOx), compared to areas of eastern and western continental Europe, western Russia, and southern Fennoscandia.

  12. Mini-D{sub 2} a source for ultracold neutrons at FRM-II

    Altarev, I.; Hartmann, F.J.; Paul, S.; Schott, W.; Trinks, U.; Gobrecht, K.; Gutsmiedl, E. [Technische Universitaet Muenchen, Garching (Germany); Scheuer, A. [TUEV Rheinland, Koeln (Germany)

    2001-03-01

    The new Munich high-flux reactor FRM-II offers the possibility to install a unique source for ultracold neutrons (UCN), the Mini-D{sub 2} UCN source, with a small volume of solid deuterium at a temperature of 5 K as converter, exposed to the cold neutron flux. This new source, being dedicated for storage experiments, is designed to be much superior to any existing UCN facility. In the pulsed operation mode the Mini-D{sub 2} source is expected to provide UCN densities up to 10{sup 4} n/cm{sup 3}. This density is orders of magnitude larger than that from the best existing source at Institut Laue Langevin (ILL) in Grenoble ({approx}50 n/cm{sup 3} at the exit of the neutron turbine). The large gain factor will enable new precision measurements of elementary properties of the free neutron, especially the electric dipole moment, the lifetime, and the angular correlation coefficients of the decay. These quantities are of fundamental interest in particle physics. Operated in the continuous mode, the UCN source will provide an UCN flux density of up to 5{center_dot}10{sup 5} n/cm{sup 2}s at the exit, to be compared with {approx}3{center_dot}10{sup 4} n/cm{sup 2}s at ILL. This improved UCN-flux offers new possibilities for traditional studies with UCN. (author)

  13. A novel polymer probe for Zn(II) detection with ratiometric fluorescence signal

    Diao, Haipeng; Guo, Lixia; Liu, Wen; Feng, Liheng

    2018-05-01

    A conjugated polymer probe comprised of fluorene, quinolone and benzothiazole units was designed and synthesized by the Suzuki coupling reaction. Through the studies of photophysical and thermal properties, the polymer displays blue-emitting feature and good thermal stability. A ratiometric fluorescence signal of the probe for Zn(II) was observed in ethanol with a new emission peak at 555 nm. The probe possesses a high selectivity and sensitivity for Zn(II) during familiar metal ions in ethanol. The detection limit of the probe for Zn (II) is up to 10-8 mol/L. The electron distributions of the polymer before and after bonding with Zn (II) were investigated by the Gaussian 09 software, which agreed with the experimental results. Noticeably, based on the color property of the probe with Zn(II), a series of color test paper were developed for visual detecting Zn(II) ions. This work helps to provide a platform or pattern for the development of polymer fluorescence probe in the chemosensor field.

  14. Biosensor technology for the detection of illegal drugs II: antibody development and detection techniques

    Hilpert, Reinhold; Bauer, Christian; Binder, Florian; Grol, Michael; Hallermayer, Klaus; Josel, Hans-Peter; Klein, Christian; Maier, Josef; Makower, Alexander; Oberpriller, Helmut; Ritter, Josef

    1994-10-01

    In a joint project of Deutsche Aerospace, Boehringer Mannheim and the University of Potsdam portable devices for the detection of illegal drugs, based on biosensor technology, are being developed. The concept enrichment of the drug from the gas phase and detection by immunological means. This publication covers the development of specific antibodies and various detection procedures. Antibodies with a high affinity for cocaine have been developed with the aid of specially synthesized immunogens. A competitive detection procedure with biosensors based on optical grating couplers and applying particulate labels has been established, showing a lower detection limit of 10-10 mol/l for cocaine. Additionally, a combination of a displacement-immunoreactor and an enzymatically amplified electrode was investigated, which at present still suffers from insufficient sensitivity of the immunoreactor. An alternative, fleece-matrix based test procedure, where enrichment and detection steps are integrated in a single unit, is promising in terms of simplicity and sensitivity. A simple swab-test for the detection of cocaine at surfaces has been developed, which has a lower detection limit of about 10 ng and which can be performed within one minute.

  15. Expansion design for a radioactive sources handling laboratory type II class B

    Sanchez S, P. S.; Monroy G, F.; Alanis, J.

    2013-10-01

    The Radioactive Wastes Research Laboratory (RWRL) of the Instituto Nacional de Investigaciones Nucleares (Mexico), at the moment has three sections: instrumental analysis, radioactive material processes, counting and a license type II class C, to manipulate radioactive material. This license limits the open sources handling to 300 kBq for radionuclides of very high radio-toxicity as the Ra-226, for what is being projected the license extension to type II class B, to be able to manage until 370 MBq of this radionuclides type, and the Laboratory, since the location where is the RWRL have unused area. This work presents a proposal of the RWRL expansion, taking into account the current laboratory sections, as well as the established specifications by the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The current planes of the RWRL and the expansion proposal of the laboratory are presented. (Author)

  16. Detecting comorbid Axis-II status among inpatients using the MMPI-2 Restructured Clinical Scales

    Kamphuis, J.H.; Arbisi, P.A.; Ben-Porath, Y.S.; McNulty, J.L.

    2008-01-01

    This study examined the differential diagnostic utility of the MMPI-2 Restructured Clinical Scales (RCS) and Clinical Scales (CS) in detecting a complex multivariate clinical phenomenon: that is, comorbid Axis-II status in two matched samples of inpatients. Psychiatric inpatients diagnosed with

  17. Detection of Sn(II) ions via quenching of the fluorescence of carbon nanodots

    Mohd Yazid, S.N.A.; Chin, S.F.; Pang, S.C.; Ng, S.M.

    2013-01-01

    We report that fluorescent carbon nanodots (C-dots) can act as an optical probe for quantifying Sn(II) ions in aqueous solution. C-dots are synthesized by carbonization and surface oxidation of preformed sago starch nanoparticles. Their fluorescence is significantly quenched by Sn(II) ions, and the effect can be used to determine Sn(II) ions. The highest fluorescence intensity is obtained at a concentration of 1.75 mM of C-dots in aqueous solution. The probe is highly selective and hardly interfered by other ions. The quenching mechanism appears to be predominantly of the static (rather than dynamic) type. Under optimum conditions, there is a linear relationship between fluorescence intensity and Sn(II) ions concentration up to 4 mM, and with a detection limit of 0.36 μM. (author)

  18. Indigenous instrumentation for mass spectrometry: Part II - development of plasma source mass spectrometers. PD-5-3

    Nataraju, V.

    2007-01-01

    The growing demands from analytical community, for a precise isotope ratio and ultra trace concentration measurements, has lead to significant improvement in mass spectrometer instrumentation development with respect to sensitivity, detection limits, precision and accuracy. Among the many analytical techniques available, plasma source mass spectrometers like Inductively Coupled Plasma Mass Spectrometry (ICPMS), multi collector (MC) ICPMS and Glow Discharge Mass Spectrometry (GDMS), have matured into reliable tools for the above applications. Where as ICPMS is by far the most successful method for aqueous solutions, GDMS is being applied for bulk and impurity analysis of conducting as well non-conducting solids. VPID, BARC has been developing mass spectrometers for different inorganic applications of DAE users. Over the years expertise has been developed in all the aspects of mass spectrometry instrumentation. Part 1 of this indigenous instrumentation on mass spectrometry gives details of magnetic sector instruments with either EI or TI source for isotopic ratio analysis. The present paper is a continuation of that on plasma source and quadrupole mass spectrometers. This paper covers i) ICP-QMS, ii) MC-ICPMS, iii) GDMS and iv) QMS

  19. First Detections of the [N II] 122 micron Line at High Redshift: Demonstrating the Utility of the Line for Studying Galaxies in the Early Universe

    Ferkinhoff, Carl; Brisbin, Drew; Nikola, Thomas; Parshley, Stephen C.; Stacey, Gordon J.; Phillips, Thomas G.; Falgarone, Edith; Benford, Dominic J.; Staguhn, Johannes G.; Tucker, Carol E.

    2011-01-01

    We report the first detections of the [N II] 122 micron line from a high-redshift galaxy. The line was strongly (>6(sigma)) detected from SMMJ02399-0136, and H1413 + 117 (the Cloverleaf QSO) using the Redshift (zeta) and Early Universe Spectrometer on the Caltech Submillimeter Observatory. The lines from both sources are quite bright with line to far-infrared (FIR) continuum luminosity ratios that are approx.7.0 x 10(exp -4) (Cloverleaf) and 2.1 x 10(exo -3) (SMMJ02399). With ratios 2-10 times larger than the average value for nearby galaxies, neither source exhibits the line to continuum deficits seen in nearby sources. The line strengths also indicate large ionized gas fractions, approx.8%-17% of the molecUlar gas mass. The [O III]/[N II] line ratio is very sensitive to the effective temperature of ionizing stars and the ionization parameter for emission arising in the narrow-line region (NLR) of an active galactic nucleus (AGN). Using Our previous detection of the [O III] 88 micron line, the [O III]/[N II]line ratio for SMMJ02399-0136 indicates that the dominant source of the line emission is either stellar H II regions ionized by O9.5 stars, or the NLR of the AGN with ionization parameter log(U) = -3.3 to -4.0. A composite system, where 30%-50% of the FIR lines arise in the NLR also matches the data. The Cloverleaf is best modeled by a superposition of approx.200 M82-like starbursts accounting for all of the FIR emission and 43% of the [N II]line. The remainder may come from the NLR. This war!< demonstrates the utility of the [N II] and [O III] lines in constraining properties of the ionized medium.

  20. FIRST 'WINGED' AND X-SHAPED RADIO SOURCE CANDIDATES. II. NEW REDSHIFTS

    Cheung, C. C.; Healey, Stephen E.; Landt, Hermine; Jordan, Andres; Verdoes Kleijn, Gijs

    2009-01-01

    We report optical spectroscopic observations of X-shaped radio sources with the Hobby-Eberly Telescope and Multiple-Mirror Telescope, focused on the sample of candidates from the FIRST survey presented in a previous paper. A total of 27 redshifts were successfully obtained, 21 of which are new, including a newly identified candidate source of this type which is presented here. With these observations, the sample of candidates from the previous paper is over 50% spectroscopically identified. Two new broad emission-lined X-shaped radio sources are revealed, while no emission lines were detected in about one-third of the observed sources; a detailed study of the line properties is deferred to a future paper. Finally, to explore their relation to the Fanaroff-Riley division, the radio luminosities and host galaxy absolute magnitudes of a spectroscopically identified sample of 50 X-shaped radio galaxies are calculated to determine their placement in the Owen-Ledlow plane.

  1. Detecting the leakage source of a reservoir using isotopes.

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. High Fidelity Down-Conversion Source for Secure Communications using On-Demand Single Photons, Phase II

    National Aeronautics and Space Administration — In this NASA SBIR Phase II effort, AdvR will design and build an efficient, fully integrated, waveguide based, source of spectrally uncorrelated photon pairs that...

  3. Detection of human papillomavirus in pterygium and conjunctival papilloma by hybrid capture II and PCR assays.

    Takamura, Y; Kubo, E; Tsuzuki, S; Akagi, Y

    2008-11-01

    To elucidate the putative role of human papillomavirus (HPV) infection in pterygium and conjunctival papilloma. Hybrid capture II (HC-II) and polymerase chain reaction (PCR) assays were performed to detect HPV in pterygium (42 samples obtained from 40 patients) and conjunctival papilloma (8 samples from 6 patients). The amount of HPV DNA was evaluated by measurement of relative light units (RLUs) on a luminometer. All papilloma samples were positive for HPV DNA by PCR and HC-II. The RLU values for specimens of recurrent and re-recurrent papilloma were markedly higher than those for specimens of primary lesions. HPV was detected by PCR in 2 of 42 (4.8%) beta-globin-positive pterygium specimens, whereas HC-II showed that HPV was negative in all pterygium samples. Our results support the hypothesis that HPV DNA is associated with the pathogenesis of conjunctival papilloma, but not pterygium. RLU measurement by HC-II may serve as a marker for evaluating the activity of HPV in conjunctival tumours.

  4. Latest experience on insertion devices at the National Synchrotron Light Source-II

    Tanabe, Toshiya; Cappadoro, Peter; Corwin, Todd

    2016-01-01

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy with the horizontal emittance of the electron beam being 0.9 nm.rad. Nine In-Vacuum Undulators (IVUs) are utilized at the NSLS-II as of February 2016. All IVUs have a unique side window derived from the experience from the CHESS facility in Cornell University. An R and D activity called 'Vacuum Seal Test' was conducted to ensure the viability of aluminum wire seal. Another R and D activity to develop a measurement system for Cryogenic Permanent Magnet Undulator (CPMU) was also performed. Other in-air devices, namely damping wigglers (DWs) and elliptically polarizing undulators (EPUs) utilize extruded aluminum chambers with Non-Evaporable Getter (NEG) coating. The beam-based integral estimates were obtained from the virtual kicks at the upstream and downstream of the undulator that best fit the measured orbit distortion in a model lattice with Tracy. In some cases, there are fairly large discrepancies between magnetic measurement data and observed integrals by the beam. Beam studies were carried out to explain the discrepancies mentioned earlier. The latest experiences on ID development and commissioning are discussed in conjunction with related activities in the world. (author)

  5. LEVIS active anode lithium ion source development on PBFA-II

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Clark, B.F.; Reyes, C.; Bailey, J.E.; Filuk, A.B.; Desjarlais, M.P.; Johnson, D.J.; Carlson, A.L.; Lake, P.

    1993-01-01

    Experiments are ongoing on the PBFA-II Accelerator (10 MV typical, 50 ns) to optimize an active lithium ion source in a 15-cm focusing Applied-B ion diode using the LEVIS (Laser Evaporation Ion Source) process. Two laser pulses impinge on a thin (500 nm) Li or Li-bearing alloy on an insulating substrate. A Nd:YAG laser beam (1 μm, 8 ns, 0.1--0.2 J/cm 2 ) creates a thin (∼1 mm) Li vapor, which is then ionized by a 30--60 mJ/cm 2 dye laser tuned to the first resonant transition of Li (670.8 nm). In order to achieve a high-purity Li beam on PBFA-II with LEVIS, it has proven necessary to clean the anode surface in some way. The principal technique has been DC-heating of the anode to temperatures of 150--200 C for typically 5 hours, and for as long as 13 hours, prior to machine firing. Use of a LiAg alloy and YAG energy densities of 200 mJ/cm 2 have yielded beams of Li purity greater than 90%. They authors also plan to test a diode configuration that deposits Li in-situ on the anode surface just prior to the machine shot, as an alternative to DC-heating

  6. The cryogenic photon detection system for the ALPS II experiment. Characterization, optimization and background rejection

    Bastidon, Noemi Alice Chloe

    2017-01-01

    The search for new fundamental bosons at very low mass is the central objective of the ALPS II experiment which is currently set up at the Deutsches Elektronen-Synchrotron (DESY, Hamburg). This experiment follows the light-shining-through-the-wall concept where photons could oscillate into weakly interacting light bosons in front of a wall and back into photons behind the wall, giving the impression that light can shine through a light tight barrier. In this concept, the background-free detection of near-infrared photons is required to fully exploit the sensitivity of the apparatus. The high efficiency single-photon detection in the near-infrared is challenging and requires a cryogenic detector. In this project, a Transition-Edge Sensor (TES) operated below 100mK will be used to detect single photons. This thesis focuses on the characterization and optimization of the ALPS II detector system including an Adiabatic Demagnetisation Refrigerator (ADR) with its two-stage pulse-tube cooler, two TES detectors and their Superconducting Quantum Interference Devices (SQUIDs) read-out system. Stability of the detection system over time is a priority in the ALPS II experiment. It is in this context that the cooling system has been subjected to many upgrades. In the framework of this thesis, the cooling setup has been studied in detail in order to optimize its cooling performances. Furthermore, the stability of the detector has been studied according to various criteria. Other essential parameters of the ALPS II experiment are its detection efficiency and its background rate. Indeed, the sensitivity of the experiment directly depends on these two characteristics. Both elements have been studied in depth in order to define if the chosen TES detector will meet ALPS IIc specifications.

  7. The cryogenic photon detection system for the ALPS II experiment. Characterization, optimization and background rejection

    Bastidon, Noemi Alice Chloe

    2017-01-12

    The search for new fundamental bosons at very low mass is the central objective of the ALPS II experiment which is currently set up at the Deutsches Elektronen-Synchrotron (DESY, Hamburg). This experiment follows the light-shining-through-the-wall concept where photons could oscillate into weakly interacting light bosons in front of a wall and back into photons behind the wall, giving the impression that light can shine through a light tight barrier. In this concept, the background-free detection of near-infrared photons is required to fully exploit the sensitivity of the apparatus. The high efficiency single-photon detection in the near-infrared is challenging and requires a cryogenic detector. In this project, a Transition-Edge Sensor (TES) operated below 100mK will be used to detect single photons. This thesis focuses on the characterization and optimization of the ALPS II detector system including an Adiabatic Demagnetisation Refrigerator (ADR) with its two-stage pulse-tube cooler, two TES detectors and their Superconducting Quantum Interference Devices (SQUIDs) read-out system. Stability of the detection system over time is a priority in the ALPS II experiment. It is in this context that the cooling system has been subjected to many upgrades. In the framework of this thesis, the cooling setup has been studied in detail in order to optimize its cooling performances. Furthermore, the stability of the detector has been studied according to various criteria. Other essential parameters of the ALPS II experiment are its detection efficiency and its background rate. Indeed, the sensitivity of the experiment directly depends on these two characteristics. Both elements have been studied in depth in order to define if the chosen TES detector will meet ALPS IIc specifications.

  8. Detecting New Pedestrian Facilities from VGI Data Sources

    Zhong, S.; Xie, Z.

    2017-12-01

    Pedestrian facility (e.g. footbridge, pedestrian crossing and underground passage) information is an important basic data of location based service (LBS) for pedestrians. However, timely updating pedestrian facility information challenges due to facilities change frequently. Previous pedestrian facility information collecting and updating tasks are mainly completed by highly trained specialized persons. However, this conventional approach has several disadvantages such as high cost, long update cycle and so on. Volunteered Geographic Information (VGI) has proven efficiency to provide new, free and fast growing spatial data. Pedestrian trajectory, which can be seen as measurements of real pedestrian road, is one of the most valuable information of VGI data. Although the accuracy of the trajectories is not too high, due to the large number of measurements, an improvement of quality of the road information can be achieved. Thus, we develop a method for detecting new pedestrian facilities based on the current road network and pedestrian trajectories. Specifically, 1) by analyzing speed, distance and direction, those outliers of pedestrian trajectories are removed, 2) a road network matching algorithm is developed for eliminating redundant trajectories, and 3) a space-time cluster algorithm is adopted for detecting new walking facilities. The performance of the method is evaluated with a series of experiments conducted on a part of the road network of Heifei and a large number of real pedestrian trajectories, and verified the results by using Tencent Street map. The results show that the proposed method is able to detecting new pedestrian facilities from VGI data accurately. We believe that the proposed method provides an alternative way for general road data acquisition, and can improve the quality of LBS for pedestrians.

  9. EEG recordings as a source for the detection of IRBD

    Bisgaard, Sissel; Duun-Christensen, Bolette; Kempfner, Lykke

    2015-01-01

    The purpose of this pilot study was to develop a supportive algorithm for the detection of idiopathic Rapid Eye-Movement (REM) sleep Behaviour Disorder (iRBD) from EEG recordings. iRBD is defined as REM sleep without atonia with no current sign of neurodegenerative disease, and is one...... of the earliest known biomarkers of Parkinson's Disease (PD). It is currently diagnosed by polysomnography (PSG), primarily based on EMG recordings during REM sleep. The algorithm was developed using data collected from 42 control subjects and 34 iRBD subjects. A feature was developed to represent high amplitude...

  10. 10C survey of radio sources at 15.7 GHz - II. First results

    AMI Consortium; Davies, Mathhew L.; Franzen, Thomas M. O.; Waldram, Elizabeth M.; Grainge, Keith J. B.; Hobson, Michael P.; Hurley-Walker, Natasha; Lasenby, Anthony; Olamaie, Malak; Pooley, Guy G.; Riley, Julia M.; Rodríguez-Gonzálvez, Carmen; Saunders, Richard D. E.; Scaife, Anna M. M.; Schammel, Michel P.; Scott, Paul F.; Shimwell, Timothy W.; Titterington, David J.; Zwart, Jonathan T. L.

    2011-08-01

    In a previous paper (Paper I), the observational, mapping and source-extraction techniques used for the Tenth Cambridge (10C) Survey of Radio Sources were described. Here, the first results from the survey, carried out using the Arcminute Microkelvin Imager Large Array (LA) at an observing frequency of 15.7 GHz, are presented. The survey fields cover an area of ≈27 deg2 to a flux-density completeness of 1 mJy. Results for some deeper areas, covering ≈12 deg2, wholly contained within the total areas and complete to 0.5 mJy, are also presented. The completeness for both areas is estimated to be at least 93 per cent. The 10C survey is the deepest radio survey of any significant extent (≳0.2 deg2) above 1.4 GHz. The 10C source catalogue contains 1897 entries and is available online. The source catalogue has been combined with that of the Ninth Cambridge Survey to calculate the 15.7-GHz source counts. A broken power law is found to provide a good parametrization of the differential count between 0.5 mJy and 1 Jy. The measured source count has been compared with that predicted by de Zotti et al. - the model is found to display good agreement with the data at the highest flux densities. However, over the entire flux-density range of the measured count (0.5 mJy to 1 Jy), the model is found to underpredict the integrated count by ≈30 per cent. Entries from the source catalogue have been matched with those contained in the catalogues of the NRAO VLA Sky Survey and the Faint Images of the Radio Sky at Twenty-cm survey (both of which have observing frequencies of 1.4 GHz). This matching provides evidence for a shift in the typical 1.4-GHz spectral index to 15.7-GHz spectral index of the 15.7-GHz-selected source population with decreasing flux density towards sub-mJy levels - the spectra tend to become less steep. Automated methods for detecting extended sources, developed in Paper I, have been applied to the data; ≈5 per cent of the sources are found to be extended

  11. Rapid and ultrasensitive colorimetric detection of mercury(II) by chemically initiated aggregation of gold nanoparticles

    Chen, Yinji; Chen, Wei; Yao, Li; Deng, Yi; Pan, Daodong; Cao, Jinxuan; Ogabiela, Edward; Adeloju, Samuel B.

    2015-01-01

    The article describes a method for rapid and visual determination of Hg(II) ion using unmodified gold nanoparticles (Au-NPs). It involves the addition of Au-NPs to a solution containing Hg(II) ions which, however, does not induce a color change. Next, a solution of lysine is added which induces the aggregation of the Au-NPs and causes the color of the solution to change from wine-red to purple. The whole on-site detection process can be executed in less than 15 min. Other amines (ethylenediamine, arginine, and melamine) were also investigated with respect to their capability to induce aggregation. Notably, only amines containing more than one amino group were found to be effective, but a 0.4 μM and pH 8 solution of lysine was found to give the best results. The detection limits for Hg (II) are 8.4 pM (for instrumental read-out) and 10 pM (for visual read-out). To the best of our knowledge, this LOD is better than those reported for any other existing rapid screening methods. The assay is not interfered by the presence of other common metal ions even if present in 1000-fold excess over Hg(II) concentration. It was successfully applied to the determination of Hg(II) in spiked tap water samples. We perceive that this method provides an excellent tool for rapid and ultrasensitive on-site determination of Hg(II) ions at low cost, with relative ease and minimal operation. (author)

  12. SOURCE REGIONS OF THE TYPE II RADIO BURST OBSERVED DURING A CME–CME INTERACTION ON 2013 MAY 22

    Mäkelä, P.; Reiner, M. J.; Akiyama, S.; Gopalswamy, N.; Krupar, V.

    2016-01-01

    We report on our study of radio source regions during the type II radio burst on 2013 May 22 based on direction-finding analysis of the Wind /WAVES and STEREO /WAVES (SWAVES) radio observations at decameter–hectometric wavelengths. The type II emission showed an enhancement that coincided with the interaction of two coronal mass ejections (CMEs) launched in sequence along closely spaced trajectories. The triangulation of the SWAVES source directions posited the ecliptic projections of the radio sources near the line connecting the Sun and the STEREO-A spacecraft. The WAVES and SWAVES source directions revealed shifts in the latitude of the radio source, indicating that the spatial location of the dominant source of the type II emission varies during the CME–CME interaction. The WAVES source directions close to 1 MHz frequencies matched the location of the leading edge of the primary CME seen in the images of the LASCO/C3 coronagraph. This correspondence of spatial locations at both wavelengths confirms that the CME–CME interaction region is the source of the type II enhancement. Comparison of radio and white-light observations also showed that at lower frequencies scattering significantly affects radio wave propagation.

  13. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  14. Enzyme-based Colorimetric and Potentiometric Biosensor for Detecting Pb (II Ions in Milk

    Hardeep Kaur

    2014-08-01

    Full Text Available The aim of the present work was to study a simple colorimetric and potentiometric biosensor based on urease inhibition by Pb (II ions for its estimation in milk samples. Urease immobilized on nylon membrane by hydrosol gel method was used as the biocomponent to demonstrate the metal effect on the enzyme activity using phenol red as the pH indicator. A lower limit detection of 38.6µm was achieved in the milk and the enzyme membranes were stable for more than two months at 4ºC. In potentiometric approach, response of an ion selective electrode (ISE to changing ammonium ion concentration as a consequence of urease inhibition by Pb (II ions was explored to achieve a detection limit of 9.66 µm. Lead specificity was attained by means of masking agents 1,10 - phenanthroline and sodium potassium tartarate. Validation of the developed biosensors was carried out with spiked milk samples.

  15. Luminescent turn-on detection of Hg(II) via the quenching of an iridium(III) complex by Hg(II)-mediated silver nanoparticles.

    Liu, Jinshui; Vellaisamy, Kasipandi; Yang, Guanjun; Leung, Chung-Hang; Ma, Dik-Lung

    2017-06-15

    A novel luminescent turn-on detection method for Hg(II) was developed. The method was based on the silver nanoparticle (AgNP)-mediated quenching of Ir(III) complex 1. The addition of Hg(II) ions causes the luminescence of complex 1 to be recovered due to the oxidation of AgNPs by Hg(II) ions to form Ag(I) and Ag/Hg amalgam. The luminescence intensity of 1 increased in accord with an increased Hg(II) concentration ranging from 0 nM to 180 nM, with the detection limit of 5 nM. This approach offers an innovative method for the quantification of Hg(II).

  16. [Sulfatide-loaded CD1d tetramer to detect typeII NKT cells in mice].

    Zhang, Gu-qin; Nie, Han-xiang; Yang, Jiong; Yu, Hong-ying

    2012-07-01

    To create a method of detecting typeII natural killer T (NKT) cells of mice. Biotinylated mouse CD1d monomers were mixed with sulfatide at a molar ratio of 1:3 (protein:lipid) and incubated at room temperature overnight, and then 80 μg of streptavidin-PE was added into 200 μg of the CD1d-sulfatide mixture and incubated at room temperature for 4 h to get sulfatide/CD1d tetramer. Flow cytometry was used to detect the percentage of typeII NKT cells in mononuclear cells (MNCs) of lung and spleen of normal mice, as well as the percentage of typeII NKT cells in spleen MNCs of mice after stimulated with sulfatide. In normal mice, the percentage of typeII NKT cells accounted for (0.875±0.096)% and (1.175±0.263)% in MNCs of spleen and lung; the percentage in spleen MNCs after activated with sulfatide was (2.75±0.603)%, which significantly increased as compared with that in normal mice (PNKT cells in mice.

  17. Theoretical and Experimental Investigation of Pyridyl thiourea Derivatives As Ionophores For Cu(II) Ion Detection

    Wan Mohd Khairul; Mohd Faizuddin Abu Hasan; Adibah Izzati Daud; Adibah Izzati Daud; Hafiza Mohamed Zuki; Ku Halim Ku Bulat; Maisara Abdul Kadir

    2016-01-01

    Copper (II) ion chemical sensors based on pyridine-thiourea derivatives; N-pyridyl-N ' -(biphenyl-4-carbonyl)thiourea (L1), and N-pyridyl-N ' -(3,5-dimethy oxybenzoyl)thiourea (L2) were synthesised, characterised, and studied as ionophores in the form of thin-films PVC membranes. The ionophores exhibited good responses towards copper (II) ion over the concentration range of 2 x 10 -4 to 10 x 10 -4 M with a limit of detection 1.34 x 10 -5 to 1.48 x 10 -5 M. The proposed sensors L1 and L2 revealed good performance in term of reproducibility and regeneration of the ionophores with low relative standard deviation (RSD) values 4.17 % and 2.74 % respectively. Besides, quantum chemical calculation performed using Gaussian 09 program indicated the oxygen (O) atom from carbonyl moiety (C=O) was the most favourite reactive site and mainly responsible for ionophore Cu(II) interaction. The obtained data revealed pyridine-thiourea derivatives offered great potential as ionophore for the detection of Cu (II) ion. (author)

  18. GALAXY CLUSTERS IN THE IRAC DARK FIELD. II. MID-INFRARED SOURCES

    Krick, J. E.; Surace, J. A.; Yan, L.; Thompson, D.; Ashby, M. L. N.; Hora, J. L.; Gorjian, V.

    2009-01-01

    We present infrared (IR) luminosities, star formation rates (SFR), colors, morphologies, locations, and active galactic nuclei (AGNs) properties of 24 μm detected sources in photometrically detected high-redshift clusters in order to understand the impact of environment on star formation (SF) and AGN evolution in cluster galaxies. We use three newly identified z = 1 clusters selected from the IRAC dark field; the deepest ever mid-IR survey with accompanying, 14 band multiwavelength data including deep Hubble Space Telescope imaging and deep wide-area Spitzer MIPS 24 μm imaging. We find 90 cluster members with MIPS detections within two virial radii of the cluster centers, of which 17 appear to have spectral energy distributions dominated by AGNs and the rest dominated by SF. We find that 43% of the star-forming sample have IR luminosities L IR > 10 11 L sun (luminous IR galaxies). The majority of sources (81%) are spirals or irregulars. A large fraction (at least 25%) show obvious signs of interactions. The MIPS-detected member galaxies have varied spatial distributions as compared to the MIPS-undetected members with one of the three clusters showing SF galaxies being preferentially located on the cluster outskirts, while the other two clusters show no such trend. Both the AGN fraction and the summed SFR of cluster galaxies increase from redshift zero to one, at a rate that is a few times faster in clusters than over the same redshift range in the field. Cluster environment does have an effect on the evolution of both AGN fraction and SFR from redshift one to the present, but does not affect the IR luminosities or morphologies of the MIPS sample. SF happens in the same way regardless of environment making MIPS sources look the same in the cluster and field, however the cluster environment does encourage a more rapid evolution with time as compared to the field.

  19. THE HST/ACS COMA CLUSTER SURVEY. II. DATA DESCRIPTION AND SOURCE CATALOGS

    Hammer, Derek; Verdoes Kleijn, Gijs; Den Brok, Mark; Peletier, Reynier F.; Hoyos, Carlos; Balcells, Marc; Aguerri, Alfonso L.; Ferguson, Henry C.; Goudfrooij, Paul; Carter, David; Guzman, Rafael; Smith, Russell J.; Lucey, John R.; Graham, Alister W.; Trentham, Neil; Peng, Eric; Puzia, Thomas H.; Jogee, Shardha; Batcheldor, Dan; Bridges, Terry J.

    2010-01-01

    The Coma cluster, Abell 1656, was the target of an HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in early 2007, the partially completed survey still covers ∼50% of the core high-density region in Coma. Observations were performed for 25 fields that extend over a wide range of cluster-centric radii (∼1.75 Mpc or 1 0 ) with a total coverage area of 274 arcmin 2 . The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the southwest region of the cluster. In this paper, we present reprocessed images and SEXTRACTOR source catalogs for our survey fields, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SEXTRACTOR Kron magnitudes based only on the measured source flux and its half-light radius. We have performed photometry for ∼73,000 unique objects; approximately one-half of our detections are brighter than the 10σ point-source detection limit at F814W = 25.8 mag (AB). The slight majority of objects (60%) are unresolved or only marginally resolved by ACS. We estimate that Coma members are 5%-10% of all source detections, which consist of a large population of unresolved compact sources (primarily globular clusters but also ultra-compact dwarf galaxies) and a wide variety of extended galaxies from a cD galaxy to dwarf low surface brightness galaxies. The red sequence of Coma member galaxies has a color-magnitude relation with a constant slope and dispersion over 9 mag (-21 F814W < -13). The initial data release for the HST-ACS Coma Treasury program was made available to the public in 2008 August. The images and catalogs described

  20. A characterization and optimization study of Gamble II as an X-ray bremsstrahlung source

    Oliphant, W.F.; Boller, J.R.; Brown, D.G.; Cooperstein, G.; Dozier, C.M.; Stephanakis, S.J.

    1982-01-01

    The adverse effects of radiation on solid state devices are strongly spectrum dependent. It is thus essential that the radiation spectrum from flash x-ray sources be available when they are used as facilities for testing electronic components. This paper describes a preliminary study in which previously developed computer codes were used to calculate the radiation spectrum produced by NRL's Gamble II pulsed power generator. To determine how well the calculated spectrum matched the experimental one, doses in CaF 2 -Mn TLD's were computed for the dosimeters placed behind various thicknesses of Cu and Pb filters and compared with the experimentally measured doses. Using a diode model that was consistent with presently understood electron beam behavior, a spectrum was generated which predicted TLD doses to within about 15% of the experimentally measured values

  1. Shielding NSLS-II light source: Importance of geometry for calculating radiation levels from beam losses

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.; Wahl, W.

    2016-11-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produces significantly higher neutron component dose to the experimental floor than a lower energy beam injection and ramped operations. Minimizing this dose will require adequate knowledge of where the miss-steered beam can occur and sufficient EM shielding close to the loss point, in order to attenuate the energy of the particles in the EM shower below the neutron production threshold (weaknesses in the design before a high radiation incident occurs. The effort required to adequately define the accelerator geometry for these codes has been greatly reduced with the implementation of the graphical interface of FLAIR to FLUKA. This made the effective shielding process for NSLS-II quite accurate and reliable. The principles used to provide supplemental shielding to the NSLS-II accelerators and the lessons learned from this process are presented.

  2. The HST/ACS Coma Cluster Survey. II. Data Description and Source Catalogs

    Hammer, Derek; Kleijn, Gijs Verdoes; Hoyos, Carlos; Den Brok, Mark; Balcells, Marc; Ferguson, Henry C.; Goudfrooij, Paul; Carter, David; Guzman, Rafael; Peletier, Reynier F.; hide

    2010-01-01

    The Coma cluster, Abell 1656, was the target of a HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in early 2007, the partially-completed survey still covers approximately 50% of the core high density region in Coma. Observations were performed for twenty-five fields with a total coverage area of 274 aremin(sup 2), and extend over a wide range of cluster-centric radii (approximately 1.75 Mpe or 1 deg). The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the south-west region of the cluster. In this paper we present SEXTRACTOR source catalogs generated from the processed images, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SEXTRACTOR Kron magnitudes based only on the measured source flux and its half-light radius. We have performed photometry for 76,000 objects that consist of roughly equal numbers of extended galaxies and unresolved objects. Approximately two-thirds of all detections are brighter than F814W=26.5 mag (AB), which corresponds to the 10sigma, point-source detection limit. We estimate that Coma members are 5-10% of the source detections, including a large population of compact objects (primarily GCs, but also cEs and UCDs), and a wide variety of extended galaxies from cD galaxies to dwarf low surface brightness galaxies. The initial data release for the HST-ACS Coma Treasury program was made available to the public in August 2008. The images and catalogs described in this study relate to our second data release.

  3. Coded moderator approach for fast neutron source detection and localization at standoff

    Littell, Jennifer [Department of Nuclear Engineering, University of Tennessee, 305 Pasqua Engineering Building, Knoxville, TN 37996 (United States); Lukosi, Eric, E-mail: elukosi@utk.edu [Department of Nuclear Engineering, University of Tennessee, 305 Pasqua Engineering Building, Knoxville, TN 37996 (United States); Institute for Nuclear Security, University of Tennessee, 1640 Cumberland Avenue, Knoxville, TN 37996 (United States); Hayward, Jason; Milburn, Robert; Rowan, Allen [Department of Nuclear Engineering, University of Tennessee, 305 Pasqua Engineering Building, Knoxville, TN 37996 (United States)

    2015-06-01

    Considering the need for directional sensing at standoff for some security applications and scenarios where a neutron source may be shielded by high Z material that nearly eliminates the source gamma flux, this work focuses on investigating the feasibility of using thermal neutron sensitive boron straw detectors for fast neutron source detection and localization. We utilized MCNPX simulations to demonstrate that, through surrounding the boron straw detectors by a HDPE coded moderator, a source-detector orientation-specific response enables potential 1D source localization in a high neutron detection efficiency design. An initial test algorithm has been developed in order to confirm the viability of this detector system's localization capabilities which resulted in identification of a 1 MeV neutron source with a strength equivalent to 8 kg WGPu at 50 m standoff within ±11°.

  4. Process Model Improvement for Source Code Plagiarism Detection in Student Programming Assignments

    Kermek, Dragutin; Novak, Matija

    2016-01-01

    In programming courses there are various ways in which students attempt to cheat. The most commonly used method is copying source code from other students and making minimal changes in it, like renaming variable names. Several tools like Sherlock, JPlag and Moss have been devised to detect source code plagiarism. However, for larger student…

  5. Goaf water detection using the grounded electrical source airborne transient electromagnetic system

    Li, D.; Ji, Y.; Guan, S.; Wu, Y.; Wang, A.

    2017-12-01

    To detect the geoelectric characteristic of goaf water, the grounded electrical source airborne transient electromagnetic (GREATEM) system (developed by Jilin University, China) is applied to the goaf water detection since its advantages of considerable prospecting depth, lateral resolution and detection efficiency. For the test of GREATEM system in goaf water detection, an experimental survey was conducted at Qinshui coal mine (Shanxi province, China). After data acquisition, noise reduction and inversion, the resistivity profiles of survey area is presented. The results highly agree the investigation information provided by Shanxi Coal Geology Geophysical Surveying Exploration Institute (China), conforming that the GREATEM system is an effective technique for resistivity detection of goaf water.

  6. Early warning system for detection of protozoal contamination of source waters

    Al-Sabi, Mohammad Nafi Solaiman; Mogensen, Claus; Berg, Tommy W.

    2012-01-01

    Ensuring water quality is an ever increasing important issue world-wide. Currently, detection of protozoa in drinking water is a costly and time consuming process. We have developed an online, real-time sensor for detection of Cryptosporidium and Giardia spp. in a range of source waters. The novel...

  7. A duplex PCR assay for the detection of Ralstonia solanacearum phylotype II strains in Musa spp.

    Gilles Cellier

    Full Text Available Banana wilt outbreaks that are attributable to Moko disease-causing strains of the pathogen Ralstonia solanacearum (Rs remain a social and economic burden for both multinational corporations and subsistence farmers. All known Moko strains belong to the phylotype II lineage, which has been previously recognized for its broad genetic basis. Moko strains are paraphyletic and are distributed among seven related but distinct phylogenetic clusters (sequevars that are potentially major threats to Musaceae, Solanaceae, and ornamental crops in many countries. Although clustered within the Moko IIB-4 sequevar, strains of the epidemiologically variant IIB-4NPB do not cause wilt on Cavendish or plantain bananas; instead, they establish a latent infection in the vascular tissues of plantains and demonstrate an expanded host range and high aggressiveness toward Solanaceae and Cucurbitaceae. Although most molecular diagnostic methods focus on strains that wilt Solanaceae (particularly potato, no relevant protocol has been described that universally detects strains of the Musaceae-infecting Rs phylotype II. Thus, a duplex PCR assay targeting Moko and IIB-4NPB variant strains was developed, and its performance was assessed using an extensive collection of 111 strains representing the known diversity of Rs Moko-related strains and IIB-4NPB variant strains along with certain related strains and families. The proposed diagnostic protocol demonstrated both high accuracy (inclusivity and exclusivity and high repeatability, detected targets on either pure culture or spiked plant extracts. Although they did not belong to the Moko clusters described at the time of the study, recently discovered banana-infecting strains from Brazil were also detected. According to our comprehensive evaluation, this duplex PCR assay appears suitable for both research and diagnostic laboratories and provides reliable detection of phylotype II Rs strains that infect Musaceae.

  8. A rhodamine B-based fluorescent sensor toward highly selective mercury (II) ions detection.

    Jiao, Yang; Zhang, Lei; Zhou, Peng

    2016-04-01

    This work presented the design, syntheses and photophysical properties of a rhodamine B-based fluorescence probe, which exhibited a sensitive and selective recognition towards mercury (II). The chemosensor RA (Rhodamine- amide- derivative) contained a 5-aminoisophthalic acid diethyl ester and a rhodamine group, and the property of spirolactone of this chemosensor RA was detected by X-ray crystal structure analyses. Chemosensor RA afforded turn-on fluorescence enhancement and displayed high brightness for Hg(2+), which leaded to the opening of the spirolactone ring and consequently caused the appearance of strong absorption at visible range, moreover, the obvious and characteristic color changed from colorless to pink was observed. We envisioned that the chemosensor RA exhibited a considerable specificity with two mercury (II) ions which was attributed to the open of spirolactone over other interference metal ions. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Detecting an infrared photon within an hour. Transition-edge detector at ALPS-II

    Dreyling-Eschweiler, Jan [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Hamburg Univ. (Germany). Inst. fuer Experimentalphysik; Horns, Dieter [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik; Collaboration: ALPS-II collaboration

    2013-09-15

    An essential design requirement of the ALPS-II experiment is the efficient detection of single photons with a very low instrumental background of 10 {mu}Hz. In 2011 the ALPS collaboration started to set up a TES detector (Transition-Edge Sensor) for ALPS-II, the second phase of the experiment. Since mid of 2013 the setup is ready for characterization in the ALPS laboratory: an ADR cryostat (Adiabatic Demagnetization Refrigerator) as millikelvin environment, a low noise SQUID (Superconducting Quantum Interference Device) with electronics for read-out and a fiber-coupled high-efficient TES for near-infrared photons as sensor. First measurements have shown a good discrimination between noise and 1064 nm signals.

  10. Fuel element failure detection experiments, evaluation of the experiments at KNK II/1 (Intermediate Report)

    Bruetsch, D

    1983-01-01

    In the frame of the fuel element failure detection experiments at KNK II with its first core the measurement devices of INTERATOM were taken into operation in August 1981 and were in operation almost continuously. Since the start-up until the end of the first KNK II core operation plugs with different fuel test areas were inserted in order to test the efficiency of the different measuring devices. The experimental results determined during this test phase and the gained experiences are described in this report and valuated. All three measuring techniques (Xenon adsorption line XAS, gas-chromatograph GC and precipitator PIT) could fulfil the expectations concerning their susceptibility. For XAS and GC the nuclide specific sensitivities as determined during the preliminary tests could be confirmed. For PIT the influences of different parameters on the signal yield could be determined. The sensitivity of the device could not be measured due to a missing reference measuring point.

  11. Detecting an infrared photon within an hour. Transition-edge detector at ALPS-II

    Dreyling-Eschweiler, Jan; Hamburg Univ.; Horns, Dieter

    2013-09-01

    An essential design requirement of the ALPS-II experiment is the efficient detection of single photons with a very low instrumental background of 10 μHz. In 2011 the ALPS collaboration started to set up a TES detector (Transition-Edge Sensor) for ALPS-II, the second phase of the experiment. Since mid of 2013 the setup is ready for characterization in the ALPS laboratory: an ADR cryostat (Adiabatic Demagnetization Refrigerator) as millikelvin environment, a low noise SQUID (Superconducting Quantum Interference Device) with electronics for read-out and a fiber-coupled high-efficient TES for near-infrared photons as sensor. First measurements have shown a good discrimination between noise and 1064 nm signals.

  12. Global dust sources detection using MODIS Deep Blue Collection 6 aerosol products

    Pérez García-Pando, C.; Ginoux, P. A.

    2015-12-01

    Our understanding of the global dust cycle is limited by a dearth of information about dust sources, especially small-scale features which could account for a large fraction of global emissions. Remote sensing sensors are the most useful tool to locate dust sources. These sensors include microwaves, visible channels, and lidar. On the global scale, major dust source regions have been identified using polar orbiting satellite instruments. The MODIS Deep Blue algorithm has been particularly useful to detect small-scale sources such as floodplains, alluvial fans, rivers, and wadis , as well as to identify anthropogenic sources from agriculture. The recent release of Collection 6 MODIS aerosol products allows to extend dust source detection to the entire land surfaces, which is quite useful to identify mid to high latitude dust sources and detect not only dust from agriculture but fugitive dust from transport and industrial activities. This presentation will overview the advantages and drawbacks of using MODIS Deep Blue for dust detection, compare to other instruments (polar orbiting and geostationary). The results of Collection 6 with a new dust screening will be compared against AERONET. Applications to long range transport of anthropogenic dust will be presented.

  13. The alkaline aluminium/hydrogen peroxide power source in the Hugin II unmanned underwater vehicle

    Hasvold, Øistein; Johansen, Kjell Håvard; Mollestad, Ole; Forseth, Sissel; Størkersen, Nils

    In 1993, The Norwegian Defence Research Establishment (FFI) demonstrated AUV-Demo, an unmanned (untethered) underwater vehicle (UUV), powered by a magnesium/dissolved oxygen seawater battery (SWB). This technology showed that an underwater range of at least 1000 nautical miles at a speed of 4 knots was possible, but also that the maximum hotel load this battery system could support was very limited. Most applications for UUV technology need more power over a shorter period of time. Seabed mapping using a multibeam echo sounder mounted on an UUV was identified as a viable application and the Hugin project was started in 1995 in cooperation with Norwegian industry. For this application, an endurance of 36 h at 4 knots was required. Development of the UUV hull and electronics system resulted in the UUV Hugin I. It carries a Ni/Cd battery of 3 kW h, allowing up to 6 h under-water endurance. In parallel, we developed a battery based on a combination of alkaline Al/air and SWB technology, using a circulating alkaline electrolyte, aluminium anodes and maintaining the oxidant concentration in the electrolyte by continuously adding hydrogen peroxide (HP) to the electrolyte. This concept resulted in a safe battery, working at ambient pressure (balanced) and with sufficient power and energy density to allow the UUV Hugin II to make a number of successive dives, each of up to 36 h duration and with only 1 h deck time between dives for HP refill and electrolyte exchange. After 100 h, an exchange of anodes takes place. The power source consists of a four-cell Al/HP battery, a DC/DC converter delivering 600 W at 30 V, circulation and dosing pumps and a battery control unit. Hugin II is now in routine use by the Norwegian Underwater Intervention AS (NUI) which operates the UUV for high-precision seabed mapping down to a water depth of 600 m.

  14. Automated detection of extended sources in radio maps: progress from the SCORPIO survey

    Riggi, S.; Ingallinera, A.; Leto, P.; Cavallaro, F.; Bufano, F.; Schillirò, F.; Trigilio, C.; Umana, G.; Buemi, C. S.; Norris, R. P.

    2016-08-01

    Automated source extraction and parametrization represents a crucial challenge for the next-generation radio interferometer surveys, such as those performed with the Square Kilometre Array (SKA) and its precursors. In this paper, we present a new algorithm, called CAESAR (Compact And Extended Source Automated Recognition), to detect and parametrize extended sources in radio interferometric maps. It is based on a pre-filtering stage, allowing image denoising, compact source suppression and enhancement of diffuse emission, followed by an adaptive superpixel clustering stage for final source segmentation. A parametrization stage provides source flux information and a wide range of morphology estimators for post-processing analysis. We developed CAESAR in a modular software library, also including different methods for local background estimation and image filtering, along with alternative algorithms for both compact and diffuse source extraction. The method was applied to real radio continuum data collected at the Australian Telescope Compact Array (ATCA) within the SCORPIO project, a pathfinder of the Evolutionary Map of the Universe (EMU) survey at the Australian Square Kilometre Array Pathfinder (ASKAP). The source reconstruction capabilities were studied over different test fields in the presence of compact sources, imaging artefacts and diffuse emission from the Galactic plane and compared with existing algorithms. When compared to a human-driven analysis, the designed algorithm was found capable of detecting known target sources and regions of diffuse emission, outperforming alternative approaches over the considered fields.

  15. A label-free colorimetric aptasensor for simple, sensitive and selective detection of Pt (II) based on platinum (II)-oligonucleotide coordination induced gold nanoparticles aggregation.

    Fan, Daoqing; Zhai, Qingfeng; Zhou, Weijun; Zhu, Xiaoqing; Wang, Erkang; Dong, Shaojun

    2016-11-15

    Herein, a gold nanoparticles (AuNPs) based label-free colorimetric aptasensor for simple, sensitive and selective detection of Pt (II) was constructed for the first time. Four bases (G-G mismatch) mismatched streptavidin aptamer (MSAA) was used to protect AuNPs from salt-induced aggregation and recognize Pt (II) specifically. Only in the presence of Pt (II), coordination occurs between G-G bases and Pt (II), leading to the activation of streptavidin aptamer. Streptavidin coated magnetic beads (MBs) were used as separation agent to separate Pt (II)-coordinated MSAA. The residual less amount of MSAA could not efficiently protect AuNPs anymore and aggregation of AuNPs will produce a colorimetric product. With the addition of Pt (II), a pale purple-to-blue color variation could be observed by the naked eye. A detection limit of 150nM and a linear range from 0.6μM to 12.5μM for Pt (II) could be achieved without any amplification. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Site Characterization of the Source Physics Experiment Phase II Location Using Seismic Reflection Data

    Sexton, E. A.; Snelson, C. M.; Chipman, V.; Emer, D. F.; White, R. L.; Emmitt, R.; Wright, A. A.; Drellack, S.; Huckins-Gang, H.; Mercadante, J.; Floyd, M.; McGowin, C.; Cothrun, C.; Bonal, N.

    2013-12-01

    An objective of the Source Physics Experiment (SPE) is to identify low-yield nuclear explosions from a regional distance. Low-yield nuclear explosions can often be difficult to discriminate among the clutter of natural and man-made explosive events (e.g., earthquakes and mine blasts). The SPE is broken into three phases. Phase I has provided the first of the physics-based data to test the empirical models that have been used to discriminate nuclear events. The Phase I series of tests were placed within a highly fractured granite body. The evolution of the project has led to development of Phase II, to be placed within the opposite end member of geology, an alluvium environment, thereby increasing the database of waveforms to build upon in the discrimination models. Both the granite and alluvium sites have hosted nearby nuclear tests, which provide comparisons for the chemical test data. Phase III of the SPE is yet to be determined. For Phase II of the experiment, characterization of the location is required to develop the geologic/geophysical models for the execution of the experiment. Criteria for the location are alluvium thickness of approximately 170 m and a water table below 170 m; minimal fracturing would be ideal. A P-wave mini-vibroseis survey was conducted at a potential site in alluvium to map out the subsurface geology. The seismic reflection profile consisted of 168 geophone stations, spaced 5 m apart. The mini-vibe was a 7,000-lb peak-force source, starting 57.5 m off the north end of the profile and ending 57.5 m past the southern-most geophone. The length of the profile was 835 m. The source points were placed every 5 m, equally spaced between geophones to reduce clipping. The vibroseis sweep was from 20 Hz down to 180 Hz over 8 seconds, and four sweeps were stacked at each shot location. The shot gathers show high signal-to-noise ratios with clear first arrivals across the entire spread and the suggestion of some shallow reflectors. The data were

  17. Prospects of detection of the first sources with SKA using matched filters

    Ghara, Raghunath; Choudhury, T. Roy; Datta, Kanan K.; Mellema, Garrelt; Choudhuri, Samir; Majumdar, Suman; Giri, Sambit K.

    2018-05-01

    The matched filtering technique is an efficient method to detect H ii bubbles and absorption regions in radio interferometric observations of the redshifted 21-cm signal from the epoch of reionization and the Cosmic Dawn. Here, we present an implementation of this technique to the upcoming observations such as the SKA1-low for a blind search of absorption regions at the Cosmic Dawn. The pipeline explores four dimensional parameter space on the simulated mock visibilities using a MCMC algorithm. The framework is able to efficiently determine the positions and sizes of the absorption/H ii regions in the field of view.

  18. Performance test of SKIROC II ASIC chip for the radiation detection

    Jun, W. J.; Namgoong, H.; Kim, B. K.; Song, H. S.; Kim, H. S.; Lee, S. H.; Choi, H. J.; Ghergherehchi, M.; Chai, J. S. [Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-04-15

    There is a PCB board called FEV8 board which can readout analog signal from any energy source, and amplify it for signal processing. For precise detection, the board had been designed to operate in wide range of energy condition, with high-resolutive detection performance. This function has the possibility of the utilization for the radiation detection. The channels of the prototype board must be evaluated to make sure that the board is perfect or not. This research had made an progress for the radiation detection as well as the electronics of the intricate combination of the measurement instrumentations. The number of the noisy channels had been measured for threshold scan, and every channels in the board had been evaluated. By improving the experimental conditions such as test script in Linux system or well designed ground condition of the test bench, much more clean data will be able to be acquisited.

  19. Early tumor detection afforded by in vivo imaging of near-infrared II fluorescence.

    Tao, Zhimin; Dang, Xiangnan; Huang, Xing; Muzumdar, Mandar D; Xu, Eric S; Bardhan, Neelkanth Manoj; Song, Haiqin; Qi, Ruogu; Yu, Yingjie; Li, Ting; Wei, Wei; Wyckoff, Jeffrey; Birrer, Michael J; Belcher, Angela M; Ghoroghchian, P Peter

    2017-07-01

    Cell-intrinsic reporters such as luciferase (LUC) and red fluorescent protein (RFP) have been commonly utilized in preclinical studies to image tumor growth and to monitor therapeutic responses. While extrinsic reporters that emit near infrared I (NIR-I: 650-950 nm) or near-infrared II (NIR-II: 1000-1700 nm) optical signals have enabled minimization of tissue autofluorescence and light scattering, it has remained unclear as to whether their use has afforded more accurate tumor imaging in small animals. Here, we developed a novel optical imaging construct comprised of rare earth lanthanide nanoparticles coated with biodegradable diblock copolymers and doped with organic fluorophores, generating NIR-I and NIR-II emissive bands upon optical excitation. Simultaneous injection of multiple spectrally-unique nanoparticles into mice bearing tumor implants established via intraperitoneal dissemination of LUC + /RFP + OVCAR-8 ovarian cancer cells enabled direct comparisons of imaging with extrinsic vs. intrinsic reporters, NIR-II vs. NIR-I signals, as well as targeted vs. untargeted exogenous contrast agents in the same animal and over time. We discovered that in vivo optical imaging at NIR-II wavelengths facilitates more accurate detection of smaller and earlier tumor deposits, offering enhanced sensitivity, improved spatial contrast, and increased depths of tissue penetration as compared to imaging with visible or NIR-I fluorescent agents. Our work further highlights the hitherto underappreciated enhancements in tumor accumulation that may be achieved with intraperitoneal as opposed to intravenous administration of nanoparticles. Lastly, we found discrepancies in the fidelity of tumor uptake that could be obtained by utilizing small molecules for in vivo as opposed to in vitro targeting of nanoparticles to disseminated tumors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    Muswema, J.L.; Ekoko, G.B.; Lukanda, V.M.; Lobo, J.K.-K.; Darko, E.O.; Boafo, E.K.

    2015-01-01

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  1. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    Muswema, J.L., E-mail: jeremie.muswem@unikin.ac.cd [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Ekoko, G.B. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Lukanda, V.M. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Democratic Republic of the Congo' s General Atomic Energy Commission, P.O. Box AE1 (Congo, The Democratic Republic of the); Lobo, J.K.-K. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Darko, E.O. [Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Boafo, E.K. [University of Ontario Institute of Technology, 2000 Simcoe St. North, Oshawa, ONL1 H7K4 (Canada)

    2015-01-15

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  2. Detection of broad ultraviolet Fe II lines in the spectrum of NGC 1068

    Snijders, M.A.J.; Netzer, Hagai; Boksenberg, A.

    1986-01-01

    Ultraviolet observations of the nucleus of NGC 1068, obtained by the IUE over a period of 5 yr, are combined to give a high signal-to-noise spectrum of this source. The ultraviolet stellar continuum, obtained by comparison with ground-based data, is subtracted to show the nuclear non-stellar component. The resulting spectrum shows clearly the presence of strong broad FeII emission bands similar to those observed in many broad-line objects. Broad profiles are also seen in other strong emission lines. These observations confirm the recent discovery of an optical Seyfert type 1 spectrum in NGC 1068. (author)

  3. Cysteine detection using a high-fluorescence sensor based on a nitrogen-doped graphene quantum dot–mercury(II) system

    Liu, Zhenzhen; Gong, Yan; Fan, Zhefeng, E-mail: zhefengfan@126.com

    2016-07-15

    A novel and highly sensitive fluorescence sensor, which was based on the recovered fluorescence of a nitrogen-doped graphene quantum dot–Hg(II) system, was developed for cysteine detection. An easy, green, one-pot synthesis of nitrogen-doped graphene quantum dots was established by using citric acid and urea as carbon and nitrogen sources, respectively. The fluorescence of nitrogen-doped graphene quantum dots was significantly quenched by Hg(II) because of the efficient electron transfer between nitrogen-doped graphene quantum dots and Hg(II). Subsequently, fluorescence was recovered gradually upon cysteine addition to form a stable complex with Hg(II). The fluorescence sensor showed a response to cysteine within a wide concentration range of 0.05–30 μmol L{sup −1}, with a detection limit of 1.3 nmol L{sup −1}. The sensor was successfully applied to detect cysteine in honey and beer samples, with a recovery range of 98–105%.

  4. Cysteine detection using a high-fluorescence sensor based on a nitrogen-doped graphene quantum dot–mercury(II) system

    Liu, Zhenzhen; Gong, Yan; Fan, Zhefeng

    2016-01-01

    A novel and highly sensitive fluorescence sensor, which was based on the recovered fluorescence of a nitrogen-doped graphene quantum dot–Hg(II) system, was developed for cysteine detection. An easy, green, one-pot synthesis of nitrogen-doped graphene quantum dots was established by using citric acid and urea as carbon and nitrogen sources, respectively. The fluorescence of nitrogen-doped graphene quantum dots was significantly quenched by Hg(II) because of the efficient electron transfer between nitrogen-doped graphene quantum dots and Hg(II). Subsequently, fluorescence was recovered gradually upon cysteine addition to form a stable complex with Hg(II). The fluorescence sensor showed a response to cysteine within a wide concentration range of 0.05–30 μmol L −1 , with a detection limit of 1.3 nmol L −1 . The sensor was successfully applied to detect cysteine in honey and beer samples, with a recovery range of 98–105%.

  5. Detecting modulated signals in modulated noise: (II) neural thresholds in the songbird forebrain.

    Bee, Mark A; Buschermöhle, Michael; Klump, Georg M

    2007-10-01

    Sounds in the real world fluctuate in amplitude. The vertebrate auditory system exploits patterns of amplitude fluctuations to improve signal detection in noise. One experimental paradigm demonstrating these general effects has been used in psychophysical studies of 'comodulation detection difference' (CDD). The CDD effect refers to the fact that thresholds for detecting a modulated, narrowband noise signal are lower when the envelopes of flanking bands of modulated noise are comodulated with each other, but fluctuate independently of the signal compared with conditions in which the envelopes of the signal and flanking bands are all comodulated. Here, we report results from a study of the neural correlates of CDD in European starlings (Sturnus vulgaris). We manipulated: (i) the envelope correlations between a narrowband noise signal and a masker comprised of six flanking bands of noise; (ii) the signal onset delay relative to masker onset; (iii) signal duration; and (iv) masker spectrum level. Masked detection thresholds were determined from neural responses using signal detection theory. Across conditions, the magnitude of neural CDD ranged between 2 and 8 dB, which is similar to that reported in a companion psychophysical study of starlings [U. Langemann & G.M. Klump (2007) Eur. J. Neurosci., 26, 1969-1978]. We found little evidence to suggest that neural CDD resulted from the across-channel processing of auditory grouping cues related to common envelope fluctuations and synchronous onsets between the signal and flanking bands. We discuss a within-channel model of peripheral processing that explains many of our results.

  6. Detection of fission signatures induced by a low-energy neutron source

    Ocherashvili, A.; Becka, A.; Mayorovb, V.; Roesgen, E.; Crochemoreb, J.-M.; Mosconi, M.; Pedersen, B.; Heger, C.

    2015-01-01

    We present a method for the detection of special nuclear materials (SNM) in shielded containers which is both sensitive and applicable under field conditions. The method uses an external pulsed neutron source to induce fission in SNM and subsequent detection of the fast prompt fission neutrons. The detectors surrounding the container under investigation are liquid scintillation detectors able to distinguish gamma rays from fast neutrons by means of the pulse shape discrimination method (PSD). One advantage of these detectors, besides the ability for PSD analysis, is that the analogue signal from a detection event is of very short duration (typically few tens of nanoseconds). This allows the use of very short coincidence gates for the detection of the prompt fission neutrons in multiple detectors while benefiting from a low accidental (background) coincidence rate yielding a low detection limit. Another principle advantage of this method derives from the fact that the external neutron source is pulsed. By proper time gating the interrogation can be conducted by epithermal and thermal source neutrons only. These source neutrons do not appear in the fast neutron signal following the PSD analysis thus providing a fundamental method for separating the interrogating source neutrons from the sample response in form of fast fission neutrons. The paper describes laboratory tests with a configuration of eight detectors in the Pulsed Neutron Interrogation Test Assembly (PUNITA). The sensitivity of the coincidence signal to fissile mass is investigated for different sample configurations and interrogation regimes.

  7. The SRP-II as a Rich Source of Data on the Psychopathic Personality

    Lester, Whitney S.; Salekin, Randall T.; Sellbom, Martin

    2013-01-01

    This study examined the factor structure, external correlates, and predictive utility of the Self-Report Psychopathy scale (SRP-II; Hare, Harpur, & Hemphill, 1989). Despite a revision of the SRP-II to address, among other criticisms, a lack of items reflecting antisocial behavior, we hypothesized that the SRP-II would have a conceptually coherent…

  8. [Demand for and the Development of Detection Techniques for Source of Schistosome Infection in China].

    Wang, Shi-ping; He, Xin; Zhou, Yun-fei

    2015-12-01

    Schistosomiasis is a type of zoonotic parasitosis that severely impairs human health. Rapid detection of infection sources is a key to the control of schistosomiasis. With the effective control of schistosomiasis in China, the detection techniques for infection sources have also been developed. The rate and the intensity of infection among humans and livestocks have been significantly decreased in China, as the control program has entered the transmission control stage in most of the endemic areas. Under this situation, the traditional etiological diagnosing techniques and common immunological methods can not afford rapid detection of infection sources of schistosomiasis. Instead, we are calling for detection methods with higher sensitivity, specificity and stability while being less time-consuming, more convenient and less costing. In recent years, many improved or novel detection methods have been applied for the epidemiological surveillance of schistosomiasis, such as the automatic scanning microscopic image acquisition system, PCR-ELISA, immunosensors, loop-mediated isothermal amplification, etc. The development of new monitoring techniques can facilitate rapid detection of schistosome infection sources in endemic areas.

  9. Developments in Polarization and Energy Control of APPLE-II Undulators at Diamond Light Source

    Longhi, E. C.; Bencok, P.; Dobrynin, A.; Rial, E. C. M.; Rose, A.; Steadman, P.; Thompson, C.; Thomson, A.; Wang, H.

    2013-03-01

    A pair of 2m long APPLE-II type undulators have been built for the I10 BLADE beamline at Diamond Light Source. These 48mm period devices have gap as well as four moveable phase axes which provide the possibility to produce the full range of elliptical polarizations as well as linear polarization tilted through a full 180deg. The mechanical layout chosen has a 'master and slave' arrangement of the phase axes on the top and bottom. This arrangement allows the use of symmetries to provide operational ease for both changing energy using only the master phase while keeping fixed linear horizontal or circular polarization, as well as changing linear polarization angle while keeping fixed energy [1]. The design allows very fast motion of the master phase arrays, without sacrifice of accuracy, allowing the possibility of mechanical polarization switching at 1Hz for dichroism experiments. We present the mechanical design features of these devices, as well as the results of magnetic measurements and shimming from before installation. Finally, we present the results of characterization of these devices by the beamline, including polarimetry, which has been done on the various modes of motion to control energy and polarization. These modes of operation have been available to users since 2011.

  10. Developments in Polarization and Energy Control of APPLE-II Undulators at Diamond Light Source

    Longhi, E C; Bencok, P; Dobrynin, A; Rial, E C M; Rose, A; Steadman, P; Thompson, C; Thomson, A; Wang, H

    2013-01-01

    A pair of 2m long APPLE-II type undulators have been built for the I10 BLADE beamline at Diamond Light Source. These 48mm period devices have gap as well as four moveable phase axes which provide the possibility to produce the full range of elliptical polarizations as well as linear polarization tilted through a full 180deg. The mechanical layout chosen has a 'master and slave' arrangement of the phase axes on the top and bottom. This arrangement allows the use of symmetries to provide operational ease for both changing energy using only the master phase while keeping fixed linear horizontal or circular polarization, as well as changing linear polarization angle while keeping fixed energy [1]. The design allows very fast motion of the master phase arrays, without sacrifice of accuracy, allowing the possibility of mechanical polarization switching at 1Hz for dichroism experiments. We present the mechanical design features of these devices, as well as the results of magnetic measurements and shimming from before installation. Finally, we present the results of characterization of these devices by the beamline, including polarimetry, which has been done on the various modes of motion to control energy and polarization. These modes of operation have been available to users since 2011.

  11. Physical and chemical properties of Red MSX Sources in the southern sky: H II regions

    Yu, Naiping; Wang, Jun-Jie; Li, Nan

    2015-01-01

    We have studied the physical and chemical properties of 18 southern Red Midcourse Space Experiment Sources (RMSs), using archival data taken from the Atacama Pathfinder Experiment (APEX) Telescope Large Area Survey of the Galaxy, the Australia Telescope Compact Array, and the Millimeter Astronomy Legacy Team Survey at 90 GHz. Most of our sources have simple cometary/unresolved radio emissions at 4.8 and/or 8.6GHz. The large number of Lyman continuum fluxes (NL) indicates they are probably massive O- or early B-type star formation regions. Archival IRAS infrared data are used to estimate the dust temperature, which is about 30 K of our sources. Then, the H2 column densities and the volume-averaged H2 number densities are estimated using the 870 μm dust emissions. Large-scale infall and ionized accretions may be occurring in G345.4881+00.3148. We also attempt to characterize the chemical properties of these RMSs through molecular line (N2H+ (1-0) and HCO+ (1-0)) observations. Most of the detected N2H+ and HCO+ emissions match well with the dust emission, implying a close link to their chemical evolution in the RMSs. We found that the abundance of N2H+ is one order of magnitude lower than that in other surveys of infrared dark clouds, and a positive correlation between the abundances of N2H+ and HCO+. The fractional abundance of N2H+ with respect to H2 seems to decrease as a function of NL. These observed trends could be interpreted as an indication of enhanced destruction of N2H+, either by CO or through dissociative recombination with electrons produced by central UV photons.

  12. Operation of the water-to-sodium leak detection system at the experimental breeder reactor II

    Osterhout, M.M.

    1978-01-01

    A water-to-sodium leak detection system was installed at the Experimental Breeder Reactor II in April 1975. The system is designed for early detection of steam generator leaks, using hydrogen meters at the sodium outlets of the evaporators and superheaters. The leak detectors operate by measuring the rate of diffusion of hydrogen from the liquid sodium through a nickel membrane into a dynamic vacuum system. The advantages of this detection system are rapid response time, high sensitivity, stability, and reliability. The system was operated on an experimental basis for the first two years. During this period, data were obtained on detector stability, reliability, maintenance needs, computer interface requirements, calibration, and background hydrogen-level fluctuations. A generic defect in the original detectors was also discovered, requiring redesign of the units. When the new units were installed and proven to be reliable, the system was made fully operational. The data from the hydrogen meters are now used as the primary basis for detection of water-to-sodium leaks

  13. Using non-invasive molecular spectroscopic techniques to detect unique aspects of protein Amide functional groups and chemical properties of modeled forage from different sourced-origins.

    Ji, Cuiying; Zhang, Xuewei; Yu, Peiqiang

    2016-03-05

    The non-invasive molecular spectroscopic technique-FT/IR is capable to detect the molecular structure spectral features that are associated with biological, nutritional and biodegradation functions. However, to date, few researches have been conducted to use these non-invasive molecular spectroscopic techniques to study forage internal protein structures associated with biodegradation and biological functions. The objectives of this study were to detect unique aspects and association of protein Amide functional groups in terms of protein Amide I and II spectral profiles and chemical properties in the alfalfa forage (Medicago sativa L.) from different sourced-origins. In this study, alfalfa hay with two different origins was used as modeled forage for molecular structure and chemical property study. In each forage origin, five to seven sources were analyzed. The molecular spectral profiles were determined using FT/IR non-invasive molecular spectroscopy. The parameters of protein spectral profiles included functional groups of Amide I, Amide II and Amide I to II ratio. The results show that the modeled forage Amide I and Amide II were centered at 1653 cm(-1) and 1545 cm(-1), respectively. The Amide I spectral height and area intensities were from 0.02 to 0.03 and 2.67 to 3.36 AI, respectively. The Amide II spectral height and area intensities were from 0.01 to 0.02 and 0.71 to 0.93 AI, respectively. The Amide I to II spectral peak height and area ratios were from 1.86 to 1.88 and 3.68 to 3.79, respectively. Our results show that the non-invasive molecular spectroscopic techniques are capable to detect forage internal protein structure features which are associated with forage chemical properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Detection of Point Sources on Two-Dimensional Images Based on Peaks

    R. B. Barreiro

    2005-09-01

    Full Text Available This paper considers the detection of point sources in two-dimensional astronomical images. The detection scheme we propose is based on peak statistics. We discuss the example of the detection of far galaxies in cosmic microwave background experiments throughout the paper, although the method we present is totally general and can be used in many other fields of data analysis. We consider sources with a Gaussian profile—that is, a fair approximation of the profile of a point source convolved with the detector beam in microwave experiments—on a background modeled by a homogeneous and isotropic Gaussian random field characterized by a scale-free power spectrum. Point sources are enhanced with respect to the background by means of linear filters. After filtering, we identify local maxima and apply our detection scheme, a Neyman-Pearson detector that defines our region of acceptance based on the a priori pdf of the sources and the ratio of number densities. We study the different performances of some linear filters that have been used in this context in the literature: the Mexican hat wavelet, the matched filter, and the scale-adaptive filter. We consider as well an extension to two dimensions of the biparametric scale-adaptive filter (BSAF. The BSAF depends on two parameters which are determined by maximizing the number density of real detections while fixing the number density of spurious detections. For our detection criterion the BSAF outperforms the other filters in the interesting case of white noise.

  15. Calculated Absolute Detection Efficiencies of Cylindrical Nal (Tl) Scintillation Crystals for Aqueous Spherical Sources

    Strindehag, O; Tollander, B

    1968-08-15

    Calculated values of the absolute total detection efficiencies of cylindrical scintillation crystals viewing spherical sources of various sizes are presented. The calculation is carried out for 2 x 2 inch and 3 x 3 inch Nal(Tl) crystals and for sources which have the radii 1/4, 1/2, 3/4 and 1 times the crystal radius. Source-detector distances of 5-20 cm and gamma energies in the range 0.1 - 5 MeV are considered. The correction factor for absorption in the sample container wall and in the detector housing is derived and calculated for a practical case.

  16. Source detection at 100 meter standoff with a time-encoded imaging system

    Brennan, J.; Brubaker, E.; Gerling, M.; Marleau, P.; Monterial, M.

    2017-01-01

    Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

  17. Transient analysis of the new Cold Source at the FRM-II

    Gutsmiedl, E.; Posselt, H.; Scheuer, A.

    2003-01-01

    The new Cold Source (CNS) at the FRM-II research reactor is completely installed. This paper reports on the results of the transient analysis in the design status for this facility for producing cold neutrons for neutron experiments, the implementation of the results in the design of the mechanical components, the measurements at the cold tests and the comparison with the data of the transient analysis. The important load cases are fixed in the system description and the design data sheet of the CNS. A transient analysis was done with the computer program ESATAN, the nodal configuration was identical with the planned system of the CNS and the boundary conditions were chosen so, that conservative results can be expected. The following transients of the load cases in the piping system behind the inpile part 1) normal storage of D 2 at the hydride storage vessel 2) breakdown of cooling system of the CNS and transfer of D 2 to the buffer tank 3) rapid charge of D 2 to the buffer tank with break of the insulation vacuum and flooding of Neon 4) reloading of the D 2 from the buffer tank to the D 2 hydride storage vessel were calculated. Additionally the temperature distribution for these transients in the connecting flanges of the systems to the inpile part were analysed. The temperature distributions in the flange region were take into account for the strength calculation of the flange construction. The chosen construction shows allowable values and a leak tight flange connection for the load cases. The piping system was designed to the lowest expected temperatures. The load cases in the moderator tank were take into account in the stress analysis and the fatigue analysis of the vacuum vessel and the moderator vessel. The results shows allowable stresses. The results shows that a transient analysis is necessary and helpful for good design of the CNS. (author)

  18. The resolution of point sources of light as analyzed by quantum detection theory

    Helstrom, C. W.

    1972-01-01

    The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  19. Resolution of point sources of light as analyzed by quantum detection theory.

    Helstrom, C. W.

    1973-01-01

    The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  20. Detection of mercury(II) ions using colorimetric gold nanoparticles on paper-based analytical devices.

    Chen, Guan-Hua; Chen, Wei-Yu; Yen, Yu-Chun; Wang, Chia-Wei; Chang, Huan-Tsung; Chen, Chien-Fu

    2014-07-15

    An on-field colorimetric sensing strategy employing gold nanoparticles (AuNPs) and a paper-based analytical platform was investigated for mercury ion (Hg(2+)) detection at water sources. By utilizing thymine-Hg(2+)-thymine (T-Hg(2+)-T) coordination chemistry, label-free detection oligonucleotide sequences were attached to unmodified gold nanoparticles to provide rapid mercury ion sensing without complicated and time-consuming thiolated or other costly labeled probe preparation processes. Not only is this strategy's sensing mechanism specific toward Hg(2+), rather than other metal ions, but also the conformational change in the detection oligonucleotide sequences introduces different degrees of AuNP aggregation that causes the color of AuNPs to exhibit a mixture variance. To eliminate the use of sophisticated equipment and minimize the power requirement for data analysis and transmission, the color variance of multiple detection results were transferred and concentrated on cellulose-based paper analytical devices, and the data were subsequently transmitted for the readout and storage of results using cloud computing via a smartphone. As a result, a detection limit of 50 nM for Hg(2+) spiked pond and river water could be achieved. Furthermore, multiple tests could be performed simultaneously with a 40 min turnaround time. These results suggest that the proposed platform possesses the capability for sensitive and high-throughput on-site mercury pollution monitoring in resource-constrained settings.

  1. Expansion design for a radioactive sources handling laboratory type II class B; Diseno de ampliacion para un laboratorio de manejo de fuentes radiactivas tipo II clase B

    Sanchez S, P. S. [Universidad Mexiquense del Bicentenario, Av. Industria Poniente s/n, Parque Industrial Dona Rosa, 52000 Lerma, Estado de Mexico (Mexico); Monroy G, F.; Alanis, J., E-mail: salvador-21@live.com.mx [ININ, Carretera Mexico-Touca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The Radioactive Wastes Research Laboratory (RWRL) of the Instituto Nacional de Investigaciones Nucleares (Mexico), at the moment has three sections: instrumental analysis, radioactive material processes, counting and a license type II class C, to manipulate radioactive material. This license limits the open sources handling to 300 kBq for radionuclides of very high radio-toxicity as the Ra-226, for what is being projected the license extension to type II class B, to be able to manage until 370 MBq of this radionuclides type, and the Laboratory, since the location where is the RWRL have unused area. This work presents a proposal of the RWRL expansion, taking into account the current laboratory sections, as well as the established specifications by the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The current planes of the RWRL and the expansion proposal of the laboratory are presented. (Author)

  2. Atmospheric Pressure Chemical Ionization Sources Used in The Detection of Explosives by Ion Mobility Spectrometry

    Waltman, Melanie J. [New Mexico Inst. of Mining and Technology, Socorro, NM (United States)

    2010-05-01

    Explosives detection is a necessary and wide spread field of research. From large shipping containers to airline luggage, numerous items are tested for explosives every day. In the area of trace explosives detection, ion mobility spectrometry (IMS) is the technique employed most often because it is a quick, simple, and accurate way to test many items in a short amount of time. Detection by IMS is based on the difference in drift times of product ions through the drift region of an IMS instrument. The product ions are created when the explosive compounds, introduced to the instrument, are chemically ionized through interactions with the reactant ions. The identity of the reactant ions determines the outcomes of the ionization process. This research investigated the reactant ions created by various ionization sources and looked into ways to manipulate the chemistry occurring in the sources.

  3. Detection limits for real-time source water monitoring using indigenous freshwater microalgae

    Rodriguez Jr, Miguel [ORNL; Greenbaum, Elias [ORNL

    2009-01-01

    This research identified toxin detection limits using the variable fluorescence of naturally occurring microalgae in source drinking water for five chemical toxins with different molecular structures and modes of toxicity. The five chemicals investigated were atrazine, Diuron, paraquat, methyl parathion, and potassium cyanide. Absolute threshold sensitivities of the algae for detection of the toxins in unmodified source drinking water were measured. Differential kinetics between the rate of action of the toxins and natural changes in algal physiology, such as diurnal photoinhibition, are significant enough that effects of the toxin can be detected and distinguished from the natural variance. This is true even for physiologically impaired algae where diminished photosynthetic capacity may arise from uncontrollable external factors such as nutrient starvation. Photoinhibition induced by high levels of solar radiation is a predictable and reversible phenomenon that can be dealt with using a period of dark adaption of 30 minutes or more.

  4. Research and Development of Landmine Detection System by a Compact Fusion Neutron Source

    Yoshikawa, Kiyoshi; Masuda, Kai; Toku, Hisayuki; Nagasaki, Kazunobu; Mizutani, Toshiyuki; Takamatsu, Teruhisa; Imoto, Masaki; Yamamoto, Yasushi; Ohnishi, Masami; Osawa, Hodaka; Hotta, Eiki; Kohno, Toshiyuki; Okino, Akitoshi; Watanabe, Masato; Yamauchi, Kunihito; Yuura, Morimasa; Shiroya, Seiji; Misawa, Tsuyoshi; Mori, Takamasa

    2005-01-01

    Current results are described on the research and development of an advanced anti-personnel landmine detection system by using a compact discharge-type fusion neutron source called IECF (Inertial-Electrostatic Confinement Fusion). Landmines are to be identified through backscattering of neutrons, and specific-energy capture γ-rays by hydrogen and nitrogen atoms in the landmine explosives.For this purpose, improvements in the IECF were made by various methods to achieve a drastic enhancement of neutron yields of more than 10 8 n/s in pulsed operation. This required R and D on the power source, as well as analysis of envisaged detection systems with multi-sensors. The results suggest promising and practical features for humanitarian landmine detection, particularly, in Afghanistan

  5. An automated multi-scale network-based scheme for detection and location of seismic sources

    Poiata, N.; Aden-Antoniow, F.; Satriano, C.; Bernard, P.; Vilotte, J. P.; Obara, K.

    2017-12-01

    We present a recently developed method - BackTrackBB (Poiata et al. 2016) - allowing to image energy radiation from different seismic sources (e.g., earthquakes, LFEs, tremors) in different tectonic environments using continuous seismic records. The method exploits multi-scale frequency-selective coherence in the wave field, recorded by regional seismic networks or local arrays. The detection and location scheme is based on space-time reconstruction of the seismic sources through an imaging function built from the sum of station-pair time-delay likelihood functions, projected onto theoretical 3D time-delay grids. This imaging function is interpreted as the location likelihood of the seismic source. A signal pre-processing step constructs a multi-band statistical representation of the non stationary signal, i.e. time series, by means of higher-order statistics or energy envelope characteristic functions. Such signal-processing is designed to detect in time signal transients - of different scales and a priori unknown predominant frequency - potentially associated with a variety of sources (e.g., earthquakes, LFE, tremors), and to improve the performance and the robustness of the detection-and-location location step. The initial detection-location, based on a single phase analysis with the P- or S-phase only, can then be improved recursively in a station selection scheme. This scheme - exploiting the 3-component records - makes use of P- and S-phase characteristic functions, extracted after a polarization analysis of the event waveforms, and combines the single phase imaging functions with the S-P differential imaging functions. The performance of the method is demonstrated here in different tectonic environments: (1) analysis of the one year long precursory phase of 2014 Iquique earthquake in Chile; (2) detection and location of tectonic tremor sources and low-frequency earthquakes during the multiple episodes of tectonic tremor activity in southwestern Japan.

  6. Detection of lead(II) ions with a DNAzyme and isothermal strand displacement signal amplification.

    Li, Wenying; Yang, Yue; Chen, Jian; Zhang, Qingfeng; Wang, Yan; Wang, Fangyuan; Yu, Cong

    2014-03-15

    A DNAzyme based method for the sensitive and selective quantification of lead(II) ions has been developed. A DNAzyme that requires Pb(2+) for activation was selected. An RNA containing DNA substrate was cleaved by the DNAzyme in the presence of Pb(2+). The 2',3'-cyclic phosphate of the cleaved 5'-part of the substrate was efficiently removed by Exonuclease III. The remaining part of the single stranded DNA (9 or 13 base long) was subsequently used as the primer for the strand displacement amplification reaction (SDAR). The method is highly sensitive, 200 pM lead(II) could be easily detected. A number of interference ions were tested, and the sensor showed good selectivity. Underground water samples were also tested, which demonstrated the feasibility of the current approach for real sample applications. It is feasible that our method could be used for DNAzyme or aptazyme based new sensing method developments for the quantification of other target analytes with high sensitivity and selectivity. © 2013 Elsevier B.V. All rights reserved.

  7. Water-Soluble N-Acetyl-L-cysteine-Capped CdTe Quantum Dots Application for Hg(II Detection

    Tianming Yang

    2013-01-01

    Full Text Available A simple, rapid, and specific method for Hg(II detection has been proposed based on the fluorescence change of N-acetyl-L-cysteine-capped CdTe quantum dots (QDs. The presence of Hg(II ions could quench the fluorescence of QDs at 565 nm and meanwhile produce new peak in 700–860 nm wavelength range. The linear response range is 20–430 nM with the detection limit at 8.0 nM Hg(II. It was found that the position of the new peak was irrelevant to the size of QDs. Furthermore, the mechanism of the quenching of QDs fluorescence by Hg(II and the appearance of new peak in near-infrared area were also discussed and deduced through ultraviolet absorption spectrum, fluorescence spectrum, and X-ray photoelectron spectrum.

  8. Fissile material detection and control facility with pulsed neutron sources and digital data processing

    Romodanov, V.L.; Chernikova, D.N.; Afanasiev, V.V.

    2010-01-01

    Full text: In connection with possible nuclear terrorism, there is long-felt need of devices for effective control of radioactive and fissile materials in the key points of crossing the state borders (airports, seaports, etc.), as well as various customs check-points. In International Science and Technology Center Projects No. 596 and No. 2978, a new physical method and digital technology have been developed for the detection of fissile and radioactive materials in models of customs facilities with a graphite moderator, pulsed neutron source and digital processing of responses from scintillation PSD detectors. Detectability of fissile materials, even those shielded with various radiation-absorbing screens, has been shown. The use of digital processing of scintillation signals in this facility is a necessary element, as neutrons and photons are discriminated in the time dependence of fissile materials responses at such loads on the electronic channels that standard types of spectrometers are inapplicable. Digital processing of neutron and photon responses practically resolves the problem of dead time and allows implementing devices, in which various energy groups of neutrons exist for some time after a pulse of source neutrons. Thus, it is possible to detect fissile materials deliberately concealed with shields having a large cross-section of absorption of photons and thermal neutrons. Two models of detection and the control of fissile materials were advanced: 1. the model based on graphite neutrons moderator and PSD scintillators with digital technology of neutrons and photons responses separation; 2. the model based on plastic scintillators and detecting of time coincidences of fission particles by digital technology. Facilities that count time coincidences of neutrons and photons occurring in the fission of fissile materials can use an Am Li source of neutrons, e.g. that is the case with the AWCC system. The disadvantages of the facility are related to the issues

  9. Anti-aggregation-based spectrometric detection of Hg(II) at physiological pH using gold nanorods

    Rajeshwari, A.; Karthiga, D.; Chandrasekaran, Natarajan; Mukherjee, Amitava, E-mail: amit.mookerjea@gmail.com

    2016-10-01

    An efficient detection method for Hg (II) ions at physiological pH (pH 7.4) was developed using tween 20-modified gold nanorods (NRs) in the presence of dithiothreitol (DTT). Thiol groups (-SH) at the end of DTT have a higher affinity towards gold atoms, and they can covalently interact with gold NRs and leads to their aggregation. The addition of Hg(II) ions prevents the aggregation of gold NRs due to the covalent bond formation between the -SH group of DTT and Hg(II) ions in the buffer system. The changes in the longitudinal surface plasmon resonance peak of gold NRs were characterized using a UV–visible spectrophotometer. The absorption intensity peak of gold NRs at 679 nm was observed to reduce after interaction with DTT, and the absorption intensity was noted to increase by increasing the concentration of Hg(II) ions. The TEM analysis confirms the morphological changes of gold NRs before and after addition of Hg(II) ions in the presence of DTT. Further, the aggregation and disaggregation of gold NRs were confirmed by particle size and zeta potential analysis. The developed method shows an excellent linearity (y = 0.001 x + 0.794) for the graph plotted between the absorption ratio and Hg(II) concentration (1 to 100 pM) under the optimized conditions. The limit of detection was noted to be 0.42 pM in the buffer system. The developed method was tested in simulated body fluid, and it was found to have a good recovery rate. - Highlights: • Tween-20 modified gold NRs used as a probe for Hg(II) at physiological pH. • TEM, particle size and surface charge analysis confirm the aggregation and • disaggregation of NRs • The sensitivity of the probe for Hg(II) ions detection was 0.42 pM. • Hg(II) estimation in simulated body fluids with good recovery.

  10. Detection prospects for high energy neutrino sources from the anisotropic matter distribution in the local universe

    Mertsch, Philipp; Rameez, Mohamed; Tamborra, Irene

    2017-01-01

    Constraints on the number and luminosity of the sources of the cosmic neutrinos detected by IceCube have been set by targeted searches for point sources. We set complementary constraints by using the 2MASS Redshift Survey (2MRS) catalogue, which maps the matter distribution of the local Universe....... Assuming that the distribution of the neutrino sources follows that of matter we look for correlations between `warm' spots on the IceCube skymap and the 2MRS matter distribution. Through Monte Carlo simulations of the expected number of neutrino multiplets and careful modelling of the detector performance...... (including that of IceCube-Gen2) we demonstrate that sources with local density exceeding $10^{-6} \\, \\text{Mpc}^{-3}$ and neutrino luminosity $L_{\

  11. The Status of Kasimov Chinggisids during the Reigns of Vasily II and Ivan III according to Written Sources

    M.A. Nesin

    2017-01-01

    Research objective: To study the issue both of the status of Kasimov Chinggisids as well as of the attitude toward the service Tatars and the Tatars who were allied to Moscow during the reigns of the great Moscow princes Vasily II and Ivan III. Research materials: Published and unpublished sources: books of official orders in the Russian state, chronicles, acts, diplomatic documents, etc. Results and novelty of the research: This work is the first comprehensive study of this topic. The ...

  12. FRET based integrated pyrene-AgNPs system for detection of Hg (II) and pyrene dimer: Applications to environmental analysis

    Walekar, Laxman S.; Hu, Peidong; Vafaei Molamahmood, Hamed; Long, Mingce

    2018-06-01

    The integrated system of pyrene and cetyltrimethyl ammonium bromide (CTAB) capped silver nanoparticles (AgNPs) with a distance (r) of 2.78 nm has been developed for the detection of Hg (II) and pyrene dimer. The interaction between pyrene and AgNPs results in the fluorescence quenching of pyrene due to the energy transfer, whose mechanism can be attributed to the Forster Resonance Energy Transfer (FRET) supported by experimental observation and theoretical calculations. The developed probe shows a highly selective and sensitive response towards Hg (II) probably due to the amalgam formation, which results in the fluorescence recovery (90%) of pyrene and color change of solution from yellowish brown to colorless. The addition of Hg (II) may increase the distance between pyrene and AgNPs undergoes the 'FRET OFF' process. This system gives a selective response towards Hg (II) over other competing metal ions. Under the optimal condition, the system offers good linearity between 0.1 and 0.6 μg mL-1 with a detection limit of 62 ng mL-1. In addition, the system also provides an effective platform for detection of pyrene in its dimer form even at very low concentrations (10 ng mL-1) on the surface of AgNPs. Therefore, it could be used as effective alternatives for the detection of Hg (II) as well as pyrene simultaneously.

  13. A dual neutron/gamma source for the Fissmat Inspection for Nuclear Detection (FIND) system.

    Doyle, Barney Lee (Sandia National Laboratories, Albuquerque, NM); King, Michael; Rossi, Paolo (Sandia National Laboratories, Albuquerque, NM); McDaniel, Floyd Del (Sandia National Laboratories, Albuquerque, NM); Morse, Daniel Henry; Antolak, Arlyn J.; Provencio, Paula Polyak (Sandia National Laboratories, Albuquerque, NM); Raber, Thomas N.

    2008-12-01

    Shielded special nuclear material (SNM) is very difficult to detect and new technologies are needed to clear alarms and verify the presence of SNM. High-energy photons and neutrons can be used to actively interrogate for heavily shielded SNM, such as highly enriched uranium (HEU), since neutrons can penetrate gamma-ray shielding and gamma-rays can penetrate neutron shielding. Both source particles then induce unique detectable signals from fission. In this LDRD, we explored a new type of interrogation source that uses low-energy proton- or deuteron-induced nuclear reactions to generate high fluxes of mono-energetic gammas or neutrons. Accelerator-based experiments, computational studies, and prototype source tests were performed to obtain a better understanding of (1) the flux requirements, (2) fission-induced signals, background, and interferences, and (3) operational performance of the source. The results of this research led to the development and testing of an axial-type gamma tube source and the design/construction of a high power coaxial-type gamma generator based on the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction.

  14. Research and development of a compact fusion neutron source for humanitarian landmine detection

    Yoshikawa, K.; Masuda, K.; Yamamoto, Y.; Takamatsu, T.; Toku, H.; Nagasaki, K.; Hotta, E.; Yamauchi, K.; Ohnishi, M.; Osawa, H.

    2005-01-01

    Research and development of the advanced anti-personnel landmine detection system by using a compact discharge-type D-D fusion neutron source called IECF (Inertial-Electrostatic Confinement Fusion) are described. Landmines are to be identified through increased backscattering of neutrons by the hydrogen atoms, and specific-energy capture γ-ray emission by hydrogen and nitrogen atoms with thermalized neutrons in the landmine explosives. For this purpose, improvements of the IECF device were studied for drastic enhancement of neutron production rates of more than 10 8 n/s in pulsed operation including R and D of robust power sources, as well as analyses of envisaged detection system with multi-sensors in parallel in order to show promising and practical features of this detection system for humanitarian landmine detection, particularly, in the aridic, or dry Afghanistan deserted area, where the soil moisture remains between 3-8%, which eventually enables effectively detection of hydrogen anomaly inherent in the landmine explosives. In this paper, improvements of the IECF are focused to be described. (author)

  15. A national reconnaissance for pharmaceuticals and other organic wastewater contaminants in the United States - II) Untreated drinking water sources

    Focazio, M.J.; Kolpin, D.W.; Barnes, K.K.; Furlong, E.T.; Meyer, M.T.; Zaugg, S.D.; Barber, L.B.; Thurman, M.E.

    2008-01-01

    Numerous studies have shown that a variety of manufactured and natural organic compounds such as pharmaceuticals, steroids, surfactants, flame retardants, fragrances, plasticizers and other chemicals often associated with wastewaters have been detected in the vicinity of municipal wastewater discharges and livestock agricultural facilities. To provide new data and insights about the environmental presence of some of these chemicals in untreated sources of drinking water in the United States targeted sites were sampled and analyzed for 100 analytes with sub-parts per billion detection capabilities. The sites included 25 ground- and 49 surface-water sources of drinking water serving populations ranging from one family to over 8 million people.

  16. Detection of emission sources using passive-remote Fourier transform infrared spectroscopy

    Demirgian, J.C.; Macha, S.M.; Darby, S.M.; Ditillo, J.

    1995-01-01

    The detection and identification of toxic chemicals released in the environment is important for public safety. Passive-remote Fourier transform infrared (FTIR) spectrometers can be used to detect these releases. Their primary advantages are their small size and ease of setup and use. Open-path FTIR spectrometers are used to detect concentrations of pollutants from a fixed frame of reference. These instruments detect plumes, but they are too large and difficult to aim to be used to track a plume to its source. Passive remote FTIR spectrometers contain an interferometer, optics, and a detector. They can be used on tripods and in some cases can be hand-held. A telescope can be added to most units. We will discuss the capability of passive-remote FTIR spectrometers to detect the origin of plumes. Low concentration plumes were released using a custom-constructed vaporizer. These plumes were detected with different spectrometers from different distances. Passive-remote spectrometers were able to detect small 10 cm on a side chemical releases at concentration-pathlengths at the low parts per million-meter (ppm-m) level

  17. Detection of autoreactive CD4 T cells using major histocompatibility complex class II dextramers

    Kuszynski Charles

    2011-07-01

    Full Text Available Abstract Background Tetramers are useful tools to enumerate the frequencies of antigen-specific T cells. However, unlike CD8 T cells, CD4 T cells - especially self-reactive cells - are challenging to detect with major histocompatibility complex (MHC class II tetramers because of low frequencies and low affinities of their T cell receptors to MHC-peptide complexes. Here, we report the use of fluorescent multimers, designated MHC dextramers that contain a large number of peptide-MHC complexes per reagent. Results The utility of MHC dextramers was evaluated in three autoimmune disease models: 1 proteolipid protein (PLP 139-151-induced experimental autoimmune encephalomyelitis in SJL/J (H-2s mice; 2 myelin oligodendrocyte glycoprotein (MOG 35-55-induced experimental autoimmune encephalomyelitis in C57Bl/6 (H-2b mice; and 3 cardiac myosin heavy chain (Myhc-α 334-352-induced experimental autoimmune myocarditis in A/J (H-2a mice. Flow cytometrically, we demonstrate that IAs/PLP 139-151, IAb/MOG 35-55 and IAk/Myhc-α 334-352 dextramers detect the antigen-sensitized cells with specificity, and with a detection sensitivity significantly higher than that achieved with conventional tetramers. Furthermore, we show that binding of dextramers, but not tetramers, is less dependent on the activation status of cells, permitting enumeration of antigen-specific cells ex vivo. Conclusions The data suggest that MHC dextramers are useful tools to track the generation and functionalities of self-reactive CD4 cells in various experimental systems.

  18. Real-time implementation of logo detection on open source BeagleBoard

    George, M.; Kehtarnavaz, N.; Estevez, L.

    2011-03-01

    This paper presents the real-time implementation of our previously developed logo detection and tracking algorithm on the open source BeagleBoard mobile platform. This platform has an OMAP processor that incorporates an ARM Cortex processor. The algorithm combines Scale Invariant Feature Transform (SIFT) with k-means clustering, online color calibration and moment invariants to robustly detect and track logos in video. Various optimization steps that are carried out to allow the real-time execution of the algorithm on BeagleBoard are discussed. The results obtained are compared to the PC real-time implementation results.

  19. Application of digital lock-in detection to Hefei Light Source turn-by-turn system

    Yang Yongliang; Wang Junhua; Sun Baogen; Chen Yuanbo; Zhou Zeran

    2010-01-01

    This paper introduces the digital lock-in detection theory and discusses its feasibility to obtain the damping rate in turn-by-turn measurement systems. Numerical simulations of this method were carried out with Matlab. Then principle presenting beam experiments were conducted on the Hefei Light Source (HLS) storage ring. The measured beta oscillation growth time is about 0.26 ms and the damping time is about 1.2 ms. Simulation and experimental results show that, the digital lock-in detection method is effective in damping rate measurement in turn-by-turn measurement systems. (authors)

  20. An open source cryostage and software analysis method for detection of antifreeze activity

    Lørup Buch, Johannes; Ramløv, H

    2016-01-01

    AFP could reliably be told apart from controls after only two minutes of recrystallisation. The goal of providing a fast, cheap and easy method for detecting antifreeze proteins in solution was met, and further development of the system can be followed at https://github.com/pechano/cryostage.......The aim of this study is to provide the reader with a simple setup that can detect antifreeze proteins (AFP) by inhibition of ice recrystallisation in very small sample sizes. This includes an open source cryostage, a method for preparing and loading samples as well as a software analysis method...

  1. Intense charge transfer surface based on graphene and thymine-Hg(II)-thymine base pairs for detection of Hg(2.).

    Li, Jiao; Lu, Liping; Kang, Tianfang; Cheng, Shuiyuan

    2016-03-15

    In this article, we developed an electrochemiluminescence (ECL) sensor with a high-intensity charge transfer interface for Hg(2+) detection based on Hg(II)-induced DNA hybridization. The sensor was fabricated by the following simple method. First, graphene oxide (GO) was electrochemically reduced onto a glassy carbon electrode through cyclic voltammetry. Then, amino-labeled double-stranded (ds)DNA was assembled on the electrode surface using 1-pyrenebutyric acid N-hydroxysuccinimide as a linker between GO and DNA. The other terminal of dsDNA, which was labeled with biotin, was linked to CdSe quantum dots via biotin-avidin interactions. Reduced graphene oxide has excellent electrical conductivity. dsDNA with T-Hg(II)-T base pairs exhibited more facile charge transfer. They both accelerate the electron transfer performance and sensitivity of the sensor. The increased ECL signals were logarithmically linear with the concentration of Hg(II) when Hg(2+) was present in the detection solution. The linear range of the sensor was 10(-11) to 10(-8)mol/L (R=0.9819) with a detection limit of 10(-11)mol/L. This biosensor exhibited satisfactory results when it was used to detect Hg(II) in real water samples. The biosensor with high-intense charge transfer performance is a prospect avenue to pursue more and more sensitive detection method. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Porphyrin-functionalized porous polysulfone membrane towards an optical sensor membrane for sorption and detection of cadmium(II)

    Zhao, Lizhi, E-mail: zhaolizhi_phd@163.com [State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tianjin Polytechnic University, Tianjin 300387 (China); Li, Min; Liu, Manman; Zhang, Yuecong [State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tianjin Polytechnic University, Tianjin 300387 (China); Wu, Chenglin [School of Pharmaceutical and Chemical Engineering, Taizhou University, Taizhou 317000, Zhejiang Province (China); Zhang, Yuzhong, E-mail: zhangyz2004cn@163.com [State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tianjin Polytechnic University, Tianjin 300387 (China)

    2016-01-15

    Highlights: • An optical sensor membrane is prepared by TMPyP and PNaSS-grafted PSF membrane. • The optical sensor membrane shows enhanced sorption for cadmium(II). • Visual and spectrophotometric detection can be achieved. • The functional membrane exhibits good stability and reusability. - Abstract: In this study, an optical sensor membrane was prepared for sorption and detection of cadmium(II) (Cd(II)) in aqueous solution. A polyanion, poly(sodium 4-styrenesulfonate) (PNaSS), was grafted onto the chloromethylated polysulfone (CMPSF) microporous membrane via surface-initiated ATRP. 5,10,15,20-tetrakis(4-N-methylpyridyl) porphyrin p-toluenesulfonate (TMPyP) was immobilized onto the PNaSS-grafted polysulfone (PSF-PNaSS) membrane through electrostatic interaction. The TMPyP-functionalized membrane exhibited an enhanced sorption for, and distinct color and spectral response to cadmium(II) (Cd(II)) in aqueous solution. Larger immobilization capacity of TMPyP on the membrane led to stronger sorption for Cd(II), and smaller one made the optical sensor have a faster (in minutes) and more sensitive response to the ion. The detection limit study indicated that the functional membrane with proper amount of TMPyP (<0.5 mg/g) could still have color and spectral response to Cd(II) solutions at an extreme low concentration (10{sup −4} mg/L). The optical sensor membrane exhibited good stability and reusability which made it efficient for various sorptive removal and detection applications.

  3. Adapting astronomical source detection software to help detect animals in thermal images obtained by unmanned aerial systems

    Longmore, S. N.; Collins, R. P.; Pfeifer, S.; Fox, S. E.; Mulero-Pazmany, M.; Bezombes, F.; Goodwind, A.; de Juan Ovelar, M.; Knapen, J. H.; Wich, S. A.

    2017-02-01

    In this paper we describe an unmanned aerial system equipped with a thermal-infrared camera and software pipeline that we have developed to monitor animal populations for conservation purposes. Taking a multi-disciplinary approach to tackle this problem, we use freely available astronomical source detection software and the associated expertise of astronomers, to efficiently and reliably detect humans and animals in aerial thermal-infrared footage. Combining this astronomical detection software with existing machine learning algorithms into a single, automated, end-to-end pipeline, we test the software using aerial video footage taken in a controlled, field-like environment. We demonstrate that the pipeline works reliably and describe how it can be used to estimate the completeness of different observational datasets to objects of a given type as a function of height, observing conditions etc. - a crucial step in converting video footage to scientifically useful information such as the spatial distribution and density of different animal species. Finally, having demonstrated the potential utility of the system, we describe the steps we are taking to adapt the system for work in the field, in particular systematic monitoring of endangered species at National Parks around the world.

  4. Data-Fusion for a Vision-Aided Radiological Detection System: Sensor dependence and Source Tracking

    Stadnikia, Kelsey; Martin, Allan; Henderson, Kristofer; Koppal, Sanjeev; Enqvist, Andreas

    2018-01-01

    The University of Florida is taking a multidisciplinary approach to fuse the data between 3D vision sensors and radiological sensors in hopes of creating a system capable of not only detecting the presence of a radiological threat, but also tracking it. The key to developing such a vision-aided radiological detection system, lies in the count rate being inversely dependent on the square of the distance. Presented in this paper are the results of the calibration algorithm used to predict the location of the radiological detectors based on 3D distance from the source to the detector (vision data) and the detectors count rate (radiological data). Also presented are the results of two correlation methods used to explore source tracking.

  5. WASTK: A Weighted Abstract Syntax Tree Kernel Method for Source Code Plagiarism Detection

    Deqiang Fu

    2017-01-01

    Full Text Available In this paper, we introduce a source code plagiarism detection method, named WASTK (Weighted Abstract Syntax Tree Kernel, for computer science education. Different from other plagiarism detection methods, WASTK takes some aspects other than the similarity between programs into account. WASTK firstly transfers the source code of a program to an abstract syntax tree and then gets the similarity by calculating the tree kernel of two abstract syntax trees. To avoid misjudgment caused by trivial code snippets or frameworks given by instructors, an idea similar to TF-IDF (Term Frequency-Inverse Document Frequency in the field of information retrieval is applied. Each node in an abstract syntax tree is assigned a weight by TF-IDF. WASTK is evaluated on different datasets and, as a result, performs much better than other popular methods like Sim and JPlag.

  6. The detection of serum homocysteine (Hcy) level in II diabetes mellitus with hyperinsulinism

    He Meiqiong; Zhang Ling; Quan Xinsheng; Zhou Youjun; Wang Ying

    2003-01-01

    To explore the relationship between serum total homocysteine (Hcy) level and II diabetes mellitus (DM) with hyperinsulinism and insulin resistance, serum total Hcy level in 30 normal subjects and 78 type II DM (38 with hyperinsulinism) are detected. The results show: the mean serum Hcy level is 11.90 ± 3.90 μmo/L, 9.21 ± 2.83 μmol/L at oral glucose tolerance test (OGTT) 1 h and 10.43 ± 3.82 μmol/L at OGTT 2h in normal subjects (n=30); 21.80 ± 7.98 μmol/L, 17.98 ± 6.83 μmol/L at OGTT 1 h and 12.58 ± 6.73 μmol/L at OGTT 2 h in DM without hyperinsulinism and angiopathy (n=40); and 19.80 ± 7.98 μmol/L, 14.50 ± 7.69 μmol/L at OGTT 1 h and 11.07 ± 6.52 μmol/L at OGTT 2 h in DM with hyperinsulinism (n=38). The Hcy level is a significant difference among three groups (P<0.001, P<0.01). Hcy level of DM with hyperinsulinism is lower than that of DM with hyperinsulinism (P<0.01). The serum Hcy level in DM is higher than that in control group, the elevated level of serum Hcy may be related to the diabetic hyperinsulinism and insulin resistance

  7. Detection limits of pollutants in water for PGNAA using Am-Be source

    Khelifi, R.; Amokrane, A.; Bode, P.

    2007-01-01

    A basic PGNAA facility with an Am-Be neutron source is described to analyze the pollutants in water. The properties of neutron flux were determined by MCNP calculations. In order to determine the efficiency curve of a HPGe detector, the prompt-gamma rays from chlorine were used and an exponential curve was fitted. The detection limits for typical water sample are also estimated using the statistical fluctuations of the background level in the areas of recorded the prompt-gamma spectrum

  8. Detection of a Very Bright Source Close to the LMC Supernova SN 1987A: Erratum

    Nisenson, P.; Papaliolios, C.; Karovska, M.; Noyes, R.

    1988-01-01

    In the Letter "Detection of a Very Bright Source Close to the LMC Supernova SN 1987A" by P. Nisenson, C. Papaliolios, M. Karovska, and R. Noyes (1987 Ap. J. [Letters], 320, L15), two of the figure labels for Figure 1 were inadvertently transposed in the production process. A corrected version of the figure appears as Plate L4. The Journal regrets the error.

  9. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    Sandoval R, G.E.; Nikolaev, V.A.

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which is determined with the shot noise. (Author)

  10. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    Sandoval, G E

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which i...

  11. Event Coverage Detection and Event Source Determination in Underwater Wireless Sensor Networks

    Zhangbing Zhou

    2015-12-01

    Full Text Available With the advent of the Internet of Underwater Things, smart things are deployed in the ocean space and establish underwater wireless sensor networks for the monitoring of vast and dynamic underwater environments. When events are found to have possibly occurred, accurate event coverage should be detected, and potential event sources should be determined for the enactment of prompt and proper responses. To address this challenge, a technique that detects event coverage and determines event sources is developed in this article. Specifically, the occurrence of possible events corresponds to a set of neighboring sensor nodes whose sensory data may deviate from a normal sensing range in a collective fashion. An appropriate sensor node is selected as the relay node for gathering and routing sensory data to sink node(s. When sensory data are collected at sink node(s, the event coverage is detected and represented as a weighted graph, where the vertices in this graph correspond to sensor nodes and the weight specified upon the edges reflects the extent of sensory data deviating from a normal sensing range. Event sources are determined, which correspond to the barycenters in this graph. The results of the experiments show that our technique is more energy efficient, especially when the network topology is relatively steady.

  12. Selective and reusable iron(II)-based molecular sensor for the vapor-phase detection of alcohols.

    Naik, Anil D; Robeyns, Koen; Meunier, Christophe F; Léonard, Alexandre F; Rotaru, Aurelian; Tinant, Bernard; Filinchuk, Yaroslav; Su, Bao Lian; Garcia, Yann

    2014-02-03

    A mononuclear iron(II) neutral complex (1) is screened for sensing abilities for a wide spectrum of chemicals and to evaluate the response function toward physical perturbation like temperature and mechanical stress. Interestingly, 1 precisely detects methanol among an alcohol series. The sensing process is visually detectable, fatigue-resistant, highly selective, and reusable. The sensing ability is attributed to molecular sieving and subsequent spin-state change of iron centers, after a crystal-to-crystal transformation.

  13. A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

    Lin, Ruixing; Xu, Lin; Zheng, Xian

    2018-03-01

    Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.

  14. Detection and monitoring of pollutant sources with Lidar/Dial techniques

    Gaudio, P; Gelfusa, M; Malizia, A; Parracino, S; Richetta, M; De Leo, L; Perrimezzi, C; Bellecci, C

    2015-01-01

    It's well known that air pollution due to anthropogenic sources can have adverse effects on humans and the ecosystem. Therefore, in the last years, surveying large regions of the atmosphere in an automatic way has become a strategic objective of various public health organizations for early detection of pollutant sources in urban and industrial areas.The Lidar and Dial techniques have become well established laser based methods for the remote sensing of the atmosphere. They are often implemented to probe almost any level of the atmosphere and to acquire information to validate theoretical models about different topics of atmospheric physics. They can also be used for environment surveying by monitoring particles, aerosols and molecules.The aim of the present work is to demonstrate the potential of these methods to detect pollutants emitted from local sources (such as particulate and/or chemical compounds) and to evaluate their concentration. This is exemplified with the help of experimental data acquired in an industrial area in the south of Italy by mean of experimental campaign by use of pollutants simulated source. For this purpose, two mobile systems Lidar and Dial have been developed by the authors. In this paper there will be presented the operating principles of the system and the results of the experimental campaign. (paper)

  15. Exploring three faint source detections methods for aperture synthesis radio images

    Peracaula, M.; Torrent, A.; Masias, M.; Lladó, X.; Freixenet, J.; Martí, J.; Sánchez-Sutil, J. R.; Muñoz-Arjonilla, A. J.; Paredes, J. M.

    2015-04-01

    Wide-field radio interferometric images often contain a large population of faint compact sources. Due to their low intensity/noise ratio, these objects can be easily missed by automated detection methods, which have been classically based on thresholding techniques after local noise estimation. The aim of this paper is to present and analyse the performance of several alternative or complementary techniques to thresholding. We compare three different algorithms to increase the detection rate of faint objects. The first technique consists of combining wavelet decomposition with local thresholding. The second technique is based on the structural behaviour of the neighbourhood of each pixel. Finally, the third algorithm uses local features extracted from a bank of filters and a boosting classifier to perform the detections. The methods' performances are evaluated using simulations and radio mosaics from the Giant Metrewave Radio Telescope and the Australia Telescope Compact Array. We show that the new methods perform better than well-known state of the art methods such as SEXTRACTOR, SAD and DUCHAMP at detecting faint sources of radio interferometric images.

  16. Hypothesis tests for the detection of constant speed radiation moving sources

    Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Sannie, Guillaume; Gameiro, Jordan; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

  17. THE Low-level Radio Frequency System for the superconducting cavities of National Synchrotron Light Source II

    Ma, H.; Rose, J.; Holub, B.; Cupolo, J.; Oliva, J.; Sikora, R.; Yeddulla, M.

    2011-01-01

    A digital low-level radio frequency (LLRF) field controller has been developed for the storage ring of The National Synchrotron Light Source-II (NSLS-II). The primary performance goal for the LLRF is to support the required RF operation of the superconducting cavities with a beam current of 500mA and a 0.14 degree or better RF phase stability. The digital field controller is FPGA-based, in a standard format 19-inch/I-U chassis. It has an option of high-level control support with MATLAB running on a local host computer through a USB2.0 port. The field controller has been field tested with the high-power superconducting RF (SRF) at Canadian light Source, and successfully stored a high beam current of 250 mA. The test results show that required specifications for the cavity RF field stability are met. This digital field controller is also currently being used as a development platform for other functional modules in the NSLS-II RF systems.

  18. 318-MHz variability of complete samples of extragalactic radio sources. II

    Dennison, B.; Broderick, J.J.; Ledden, J.E.; O'Dell, S.L.; Condon, J.J.

    1981-01-01

    We report the remainder of two- and three-epoch 318-MHz observations of extragalactic sources in samples complete to 3 Jy at 1400 MHz and 1 Jy at 5000 MHz. From analysis of this low-frequency variability survey, we find that steep-spectrum (α> or =0.5) sources do not appear to vary, but about 40% of all flat-spectrum (α<0.5) sources exhibit low-frequency variability exceeding 8% over approx.5 yr. Among the flat-spectrum sources, those with inverted spectra show the largest fractional variations. We also find that the incidence of low-frequency variability is strongly correlated with the determination that a source is an optically violent variable. These statistical properties are consistent with models invoking relativistic beaming of radio and optical emission

  19. Study of improved K{sub S}{sup 0} detection at the Belle II detector

    Koch, Leonard; Kuehn, Wolfgang; Lange, Soeren [II. Physikalisches Institut, JLU Giessen (Germany); Collaboration: Belle II-Collaboration

    2016-07-01

    In the near future, the Belle II experiment at the SuperKEKB accelerator at KEK in Tsukuba, Japan, will start operation at a luminosity a factor 40 higher than its predecessor experiment, Belle. The physics program includes the search for physics beyond the Standard Model of particle physics by the investigation of CP violating processes and rare B meson decays. Many important decay channels involve K{sub S}{sup 0} mesons. The detector features two layers of silicon pixel cells (PXD) closest to the interaction point surrounded by four layers of double sided silicon strip detectors (SVD). The high background level of the Pixel Detector requires an online data reduction system: Using the SVD and the surrounding detectors, the online reconstructed tracks of charged particles are extrapolated to the PXD layers, where Regions of Interest (ROIs) are defined around the intercepts. Only the pixel data inside these ROIs are stored. Thus, particles creating an insufficient number of hits in the outer detectors are not reconstructed and subsequently no ROIs are created, resulting in the loss of the related hits in the Pixel Detector. As a consequence, particles creating a sufficient number of hits in all six layers, but not in the outer four, are lost. In this contribution, we perform online tracking using all six layers to find the tracks of pions for improved K{sub S}{sup 0} detection. The combinatorics of the hit-track assignments is reduced by artificial neural networks.

  20. Colorimetric detection of manganese(II) ions using gold/dopa nanoparticles.

    Narayanan, Kannan Badri; Park, Hyun Ho

    2014-10-15

    We report here a one-pot, greener, eco-friendly strategy for the synthesis of gold nanoparticles using L-dopa. The as-prepared dopa-functionalized gold nanoparticles (AuNPs/dopa) can detect low concentrations of manganese(II) metal ions in aqueous solution. The binding forces between dopa and Mn(2+) ions cause dopa-functionalized gold nanoparticles to come closer together, decreasing the interparticle distance and aggregating it with a change in color of colloidal solution from red to purplish-blue. Dynamic light scattering (DLS) analysis showed a decreased surface charge on the surface of gold nanoparticles when exposed to Mn(2+) ions, which caused cross-linking aggregation. Transmission electron microscopic (TEM) images also revealed the aggregation of gold nanoparticles with the addition of Mn(2+) ions. The extinction ratio of absorbance at 700-550nm (A700/A550) was linear against the concentration of [Mn(2+)] ions. Thus, the optical absorption spectra of gold colloidal solution before and after the addition of Mn(2+) ions reveal the concentration of Mn(2+) ions in solution. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. [Detection of putative polysaccharide biosynthesis genes in Azospirillum brasilense strains from serogroups I and II].

    Petrova, L P; Prilipov, A G; Katsy, E I

    2017-01-01

    It is known that in Azospirillum brasilense strains Sp245 and SR75 included in serogroup I, the repeat units of their O-polysaccharides consist of five residues of D-rhamnose, and in strain SR15, of four; and the heteropolymeric O-polysaccharide of A. brasilense type strain Sp7 from serogroup II contains not less than five types of repeat units. In the present work, a complex of nondegenerate primers to the genes of A. brasilense Sp245 plasmids AZOBR_p6, AZOBR_p3, and AZOBR_p2, which encode putative enzymes for the biosynthesis of core oligosaccharide and O-polysaccharide of lipopolysaccharide, capsular polysaccharides, and exopolysaccharides, was proposed. By using the designed primers, products of the expected sizes were synthesized in polymerase chain reactions on genomic DNA of A. brasilense Sp245, SR75, SR15, and Sp7 in 36, 29, 23, and 12 cases, respectively. As a result of sequencing of a number of amplicons, a high (86–99%) level of identity of the corresponding putative polysaccharide biosynthesis genes in three A. brasilense strains from serogroup I was detected. In a blotting-hybridization reaction with the biotin-labeled DNA of the A. brasilense gene AZOBR_p60122 coding for putative permease of the ABC transporter of polysaccharides, localization of the homologous gene in ~120-MDa plasmids of the bacteria A. brasilense SR15 and SR75 was revealed.

  2. Space-Based Detection of Missing Sulfur Dioxide Sources of Global Air Pollution

    McLinden, Chris A.; Fioletov, Vitali; Shephard, Mark W.; Krotkov, Nick; Li, Can; Martin, Randall V.; Moran, Michael D.; Joiner, Joanna

    2016-01-01

    Sulfur dioxide is designated a criteria air contaminant (or equivalent) by virtually all developed nations. When released into the atmosphere, sulfur dioxide forms sulfuric acid and fine particulate matter, secondary pollutants that have significant adverse effects on human health, the environment and the economy. The conventional, bottom-up emissions inventories used to assess impacts, however, are often incomplete or outdated, particularly for developing nations that lack comprehensive emission reporting requirements and infrastructure. Here we present a satellite-based, global emission inventory for SO2 that is derived through a simultaneous detection, mapping and emission-quantifying procedure, and thereby independent of conventional information sources. We find that of the 500 or so large sources in our inventory, nearly 40 are not captured in leading conventional inventories. These missing sources are scattered throughout the developing world-over a third are clustered around the Persian Gulf-and add up to 7 to 14 Tg of SO2 yr(exp -1), or roughly 6-12% of the global anthropogenic source. Our estimates of national total emissions are generally in line with conventional numbers, but for some regions, and for SO2 emissions from volcanoes, discrepancies can be as large as a factor of three or more. We anticipate that our inventory will help eliminate gaps in bottom-up inventories, independent of geopolitical borders and source types.

  3. Detection prospects for high energy neutrino sources from the anisotropic matter distribution in the local Universe

    Mertsch, Philipp; Rameez, Mohamed; Tamborra, Irene, E-mail: mertsch@nbi.ku.dk, E-mail: mohamed.rameez@nbi.ku.dk, E-mail: tamborra@nbi.ku.dk [Niels Bohr International Academy, Niels Bohr Institute, Blegdamsvej 17, 2100 Copenhagen (Denmark)

    2017-03-01

    Constraints on the number and luminosity of the sources of the cosmic neutrinos detected by IceCube have been set by targeted searches for point sources. We set complementary constraints by using the 2MASS Redshift Survey (2MRS) catalogue, which maps the matter distribution of the local Universe. Assuming that the distribution of the neutrino sources follows that of matter, we look for correlations between ''warm'' spots on the IceCube skymap and the 2MRS matter distribution. Through Monte Carlo simulations of the expected number of neutrino multiplets and careful modelling of the detector performance (including that of IceCube-Gen2), we demonstrate that sources with local density exceeding 10{sup −6} Mpc{sup −3} and neutrino luminosity L {sub ν} ∼< 10{sup 42} erg s{sup −1} (10{sup 41} erg s{sup −1}) will be efficiently revealed by our method using IceCube (IceCube-Gen2). At low luminosities such as will be probed by IceCube-Gen2, the sensitivity of this analysis is superior to requiring statistically significant direct observation of a point source.

  4. Design and construction of an explosive detection system by Tna methods, using 252Cf radioisotope source

    Tavakkoli Farsouli, A.

    1999-01-01

    Bombs concealed in luggage have threatened human life and property throughout the world's traffic. The plastic explosives could not checked by the X-ray detecting device. Thermal Neutron Activation method has been tested in the present work for non-destructive detection of explosives. A radioisotope neutron source 252 Cf and two gamma spectroscopy systems have been used as a tool to find explosives, regardless of the bomb's shape and the packing materials. The MCNP code has been used to design the neutronic section of the system. The measured thermal neutron fluxes by the gold foils in some location of the system were in good agreement with those data obtained by the MCNP code. Also, detection limits for nitrogen in various counting times were measured. The measurements show that the system is capable to detect 417 gr of HMX explosive material (158 gr nitrogen) by 10 minutes of counting time. To modify the system and to decrease the detection limits some opinions are given

  5. Shadow Detection Based on Regions of Light Sources for Object Extraction in Nighttime Video

    Gil-beom Lee

    2017-03-01

    Full Text Available Intelligent video surveillance systems detect pre-configured surveillance events through background modeling, foreground and object extraction, object tracking, and event detection. Shadow regions inside video frames sometimes appear as foreground objects, interfere with ensuing processes, and finally degrade the event detection performance of the systems. Conventional studies have mostly used intensity, color, texture, and geometric information to perform shadow detection in daytime video, but these methods lack the capability of removing shadows in nighttime video. In this paper, a novel shadow detection algorithm for nighttime video is proposed; this algorithm partitions each foreground object based on the object’s vertical histogram and screens out shadow objects by validating their orientations heading toward regions of light sources. From the experimental results, it can be seen that the proposed algorithm shows more than 93.8% shadow removal and 89.9% object extraction rates for nighttime video sequences, and the algorithm outperforms conventional shadow removal algorithms designed for daytime videos.

  6. Deep UV Semiconductor Sources for Advanced Planetary Science Instruments, Phase II

    National Aeronautics and Space Administration — This proposal addresses the need for miniature, narrow-linewidth, deep UV optical sources that operate at very low ambient temperatures for use in advanced in situ...

  7. International Seminar on Advanced Pulsed Neutron Sources PANS-II. Invited talks

    Pepelyshev, Yu.N.

    1994-01-01

    A conceptual design of creating intense pulsed neutron sources based on high-current accelerators and pulsed reactors for neutron scattering experiments is considered. The progress in high-efficiency moderator developments is shown. Results of diffraction studied are presented

  8. A Portable Source of Lattice-Trapped and Ultracold Strontium (PLUS), Phase II

    National Aeronautics and Space Administration — We propose to demonstrate the portable source of lattice-trapped, ultracold strontium (PLUS) designed during Phase I. The device uses simplified and robust...

  9. Narrow Wavelength, Frequency Modulated Source at 1.5 Wavelength, Phase II

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, tunable, high reliability sources at 1.5 or 2mm are needed for high performance LIDARs for several NASA applications, including wind...

  10. Expansion design for a Laboratory of Radioactive Sources Handling type II, class B

    Sanchez S, P. S.

    2014-01-01

    This work presents the expansion design of the Radioactive Wastes Research Laboratory (RWRL) installation authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico) as type II class C, to manage 40 different radionuclides, approximately. The RWRL has 4 areas at the present time: a laboratory of instrumental analysis, one of radioactive material processes, other of counting and a chemical reagents stock, which is not integrated to the operation license of the RWRL. With the purpose of expanding the operation license of the RWRL to an installation type II class B, to manage until 370 MBq of high radio toxicity radionuclides, is presented in this work an expansion proposal of the RWRL. The expansion proposal is based in: (1) the Mexican Nuclear Standard NOM-027-Nucl-1996 for installations type II class B, (2) the current distribution of water, light, electricity, extraction, gas, air and vacuum services of RWRL, and (3) the available areas inside the building that the RWRL occupies. The proposal contemplates the creation of additional new areas for RWRL: 3 laboratories, 2 dressing rooms, 2 bathrooms and 2 warehouses, one for radioactive materials and another for reagents chemical radiologically inactive. Architectural, electric, hydraulic, extraction and gas planes corresponding to the expansion of RWRL were realized. Inside the proposal the budget required to carry out the mentioned expansion is also presented. (Author)

  11. Statistical Detection of the He ii Transverse Proximity Effect: Evidence for Sustained Quasar Activity for >25 Million Years

    Schmidt, Tobias M. [Department of Physics, University of California, Santa Barbara, Santa Barbara, CA (United States); Max-Planck-Institut für Astronomie, Heidelberg (Germany); Worseck, Gabor [Max-Planck-Institut für Astronomie, Heidelberg (Germany); Hennawi, Joseph F. [Department of Physics, University of California, Santa Barbara, Santa Barbara, CA (United States); Max-Planck-Institut für Astronomie, Heidelberg (Germany); Prochaska, J. Xavier [Department of Astronomy and Astrophysics, UCO/Lick Observatory, University of California, Santa Cruz, Santa Cruz, CA (United States); Crighton, Neil H. M. [Centre for Astrophysics and Supercomputing, Swinburne University of Technology, Melbourne, VIC (Australia); Lukić, Zarija [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Oñorbe, Jose, E-mail: tschmidt@mpia.de [Max-Planck-Institut für Astronomie, Heidelberg (Germany)

    2017-10-17

    The reionization of helium at z ~ 3 is the final phase transition of the intergalactic medium and supposed to be driven purely by quasars. The He ii transverse proximity effect—enhanced He ii transmission in a background sightline caused by the ionizing radiation of a foreground quasar—therefore offers a unique opportunity to probe the morphology of He ii reionization and to investigate the emission properties of quasars, e.g., ionizing emissivity, lifetime and beaming geometry. We use the most-recent HST/COS far-UV dataset of 22 He ii absorption spectra and conduct our own dedicated optical spectroscopic survey to find foreground quasars around these He ii sightlines. Based on a set of 66 foreground quasars, we perform the first statistical analysis of the He ii transverse proximity effect. Despite a large object-to-object variance, our stacking analysis reveals an excess in the average He ii transmission near the foreground quasars at 3σ significance. This statistical evidence for the transverse proximity effect is corroborated by a clear dependence of the signal strength on the inferred He ii ionization rate at the background sightline. Our detection places, based on the transverse light crossing time, a geometrical limit on the quasar lifetime of t{sub Q} > 25 Myr. This evidence for sustained activity of luminous quasars is relevant for the morphology of H i and He ii reionization and helps to constrain AGN triggering mechanisms, accretion physics and models of black hole mass assembly. We show how future modeling of the transverse proximity effect can additionally constrain quasar emission geometries and e.g., clarify if the large observed object-to-object variance can be explained by current models of quasar obscuration.

  12. Passive monitoring for near surface void detection using traffic as a seismic source

    Zhao, Y.; Kuzma, H. A.; Rector, J.; Nazari, S.

    2009-12-01

    In this poster we present preliminary results based on our several field experiments in which we study seismic detection of voids using a passive array of surface geophones. The source of seismic excitation is vehicle traffic on nearby roads, which we model as a continuous line source of seismic energy. Our passive seismic technique is based on cross-correlation of surface wave fields and studying the resulting power spectra, looking for "shadows" caused by the scattering effect of a void. High frequency noise masks this effect in the time domain, so it is difficult to see on conventional traces. Our technique does not rely on phase distortions caused by small voids because they are generally too tiny to measure. Unlike traditional impulsive seismic sources which generate highly coherent broadband signals, perfect for resolving phase but too weak for resolving amplitude, vehicle traffic affords a high power signal a frequency range which is optimal for finding shallow structures. Our technique results in clear detections of an abandoned railroad tunnel and a septic tank. The ultimate goal of this project is to develop a technology for the simultaneous imaging of shallow underground structures and traffic monitoring near these structures.

  13. Use of Portal Monitors for Detection of Technogenic Radioactive Sources in Scrap Metal

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    The article considers the features of organization of scrap-metal primary radiation control on the specialized enterprises engaging in its deep processing and storage at using by primary technical equipment - radiation portal monitors. The issue of this direction relevance, validity of radiation control implementation with the use of radiation portal monitors, physical and organizational bases of radiation control are considered in detail. The emphasis is put on the considerable increase in the number of technogenic radioactive sources detected in scrap-metal that results in the entering into exploitation of radioactive metallic structures as different building wares. One of reasons of such increase of the number of technogenic radioactive sources getting for processing with scrap-metal is the absence of any recommendations on the radiation portal monitors exploitation. The practical division of the article offers to recommendation on tuning of the modes of work of radiation portal monitors depending on influence the weather factor thus allowing to considerably increase the percent of technogenic radioactive sources detection.

  14. Source apportionment of ambient volatile organic compounds in the Pearl River Delta, China: Part II

    Liu, Ying; Shao, Min; Lu, Sihua; Chang, Chih-Chung; Wang, Jia-Lin; Fu, Linlin

    The chemical mass balance receptor model was applied to the source apportionment of 58 hydrocarbons measured at seven sites in a field campaign that examined regional air quality in the Pearl River Delta (PRD) region in the fall of 2004. A total of 12 volatile organic compound (VOC) emission sources were considered, including gasoline- and diesel-powered vehicle exhausts, headspace vapors of gasoline and diesel fuel, vehicle evaporative emissions, liquid petroleum gas (LPG) leakage, paint vapors, asphalt emissions from paved roads, biomass combustion, coal combustion, the chemical industry, and petroleum refineries. Vehicle exhaust was the largest source of VOCs, contributing to >50% of ambient VOCs at the three urban sites (Guangzhou, Foshan, and Zhongshan). LPG leakage played an important role, representing 8-16% of emissions at most sites in the PRD. Solvent usage was the biggest emitter of VOCs at Dongguan, an industrial site, contributing 33% of ambient VOCs. Similarly, at Xinken, a non-urban site, the evaporation of solvents and coatings was the largest emission source, accounting for 31% of emissions, probably because it was downwind of Dongguan. Local biomass combustion was a noticeable source of VOCs at Xinken; although its contribution was estimated at 14.3%, biomass combustion was the third largest VOC source at this site.

  15. Sensitivity and specificity of four assays to detect human T-lymphotropic virus type I or type I/II antibodies

    Vrielink, H.; Reesink, H. W.; Zaaijer, H. L.; van der Poel, C. L.; Cuypers, H. T.; Lelie, P. N.

    1996-01-01

    BACKGROUND: Assays that detect human T-lymphotropic virus type I and type II antibody (HTLV-I/II) are widely used in the routine screening of blood donors. STUDY DESIGN AND METHODS: Four commercially available anti-HTLV-I (Fujirebio and Organon Teknika) or -HTLV-I/II assays (Murex and Ortho) were

  16. Astronomers Detect Powerful Bursting Radio Source Discovery Points to New Class of Astronomical Objects

    2005-03-01

    Astronomers at Sweet Briar College and the Naval Research Laboratory (NRL) have detected a powerful new bursting radio source whose unique properties suggest the discovery of a new class of astronomical objects. The researchers have monitored the center of the Milky Way Galaxy for several years and reveal their findings in the March 3, 2005 edition of the journal, “Nature”. This radio image of the central region of the Milky Way Galaxy holds a new radio source, GCRT J1745-3009. The arrow points to an expanding ring of debris expelled by a supernova. CREDIT: N.E. Kassim et al., Naval Research Laboratory, NRAO/AUI/NSF Principal investigator, Dr. Scott Hyman, professor of physics at Sweet Briar College, said the discovery came after analyzing some additional observations from 2002 provided by researchers at Northwestern University. “"We hit the jackpot!” Hyman said referring to the observations. “An image of the Galactic center, made by collecting radio waves of about 1-meter in wavelength, revealed multiple bursts from the source during a seven-hour period from Sept. 30 to Oct. 1, 2002 — five bursts in fact, and repeating at remarkably constant intervals.” Hyman, four Sweet Briar students, and his NRL collaborators, Drs. Namir Kassim and Joseph Lazio, happened upon transient emission from two radio sources while studying the Galactic center in 1998. This prompted the team to propose an ongoing monitoring program using the National Science Foundation’s Very Large Array (VLA) radio telescope in New Mexico. The National Radio Astronomy Observatory, which operates the VLA, approved the program. The data collected, laid the groundwork for the detection of the new radio source. “Amazingly, even though the sky is known to be full of transient objects emitting at X- and gamma-ray wavelengths,” NRL astronomer Dr. Joseph Lazio pointed out, “very little has been done to look for radio bursts, which are often easier for astronomical objects to produce

  17. AN IN-DEPTH VIEW OF THE MID-INFRARED PROPERTIES OF POINT SOURCES AND THE DIFFUSE ISM IN THE SMC GIANT H II REGION, N66

    Whelan, David G.; Johnson, Kelsey E.; Indebetouw, Rémy; Lebouteiller, Vianney; Galliano, Frédéric; Peeters, Els; Bernard-Salas, Jeronimo; Brandl, Bernhard R.

    2013-01-01

    The focus of this work is to study mid-infrared point sources and the diffuse interstellar medium (ISM) in the low-metallicity (∼0.2 Z ☉ ) giant H II region N66 in order to determine properties that may shed light on star formation in these conditions. Using the Spitzer Space Telescope's Infrared Spectrograph, we study polycyclic aromatic hydrocarbon (PAH), dust continuum, silicate, and ionic line emission from 14 targeted infrared point sources as well as spectra of the diffuse ISM that is representative of both the photodissociation regions (PDRs) and the H II regions. Among the point source spectra, we spectroscopically confirm that the brightest mid-infrared point source is a massive embedded young stellar object, we detect silicates in emission associated with two young stellar clusters, and we see spectral features of a known B[e] star that are commonly associated with Herbig Be stars. In the diffuse ISM, we provide additional evidence that the very small grain population is being photodestroyed in the hard radiation field. The 11.3 μm PAH complex emission exhibits an unexplained centroid shift in both the point source and ISM spectra that should be investigated at higher signal-to-noise and resolution. Unlike studies of other regions, the 6.2 μm and 7.7 μm band fluxes are decoupled; the data points cover a large range of I 7.7 /I 11.3 PAH ratio values within a narrow band of I 6.2 /I 11.3 ratio values. Furthermore, there is a spread in PAH ionization, being more neutral in the dense PDR where the radiation field is relatively soft, but ionized in the diffuse ISM/PDR. By contrast, the PAH size distribution appears to be independent of local ionization state. Important to unresolved studies of extragalactic low-metallicity star-forming regions, we find that emission from the infrared-bright point sources accounts for only 20%-35% of the PAH emission from the entire region. These results make a comparative data set to other star-forming regions with

  18. Performance Evaluation of Monolith Based Immobilized Acetylcholinesterase Flow-Through Reactor for Copper(II Determination with Spectrophotometric Detection

    Parawee Rattanakit

    2014-01-01

    Full Text Available A monolith based immobilized acetylcholinesterase (AChE flow-through reactor has been developed for the determination of copper(II using flow injection spectrophotometric system. The bioreactor was prepared inside a microcapillary column by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2,2-dimethoxy-1,2-diphynyletane-1-one in the presence of 1-decanol, followed by vinyl azlactone functionalization and AChE immobilization. The behavior of AChE before and after being immobilized on the monolith was evaluated by kinetic parameters from Lineweaver and Burk equation. The detection was based on measuring inhibition effect on the enzymatic activity of AChE by copper(II using Ellman’s reaction with spectrophotometric detection at 410 nm. The linear range of the calibration graph was obtained over the range of 0.02–3.00 mg L−1. The detection limit, defined as 10% inhibition (I10, was found to be 0.04 mg L−1. The repeatability was 3.35 % (n=5 for 1.00 mg L−1 of copper(II. The proposed method was applied to the determination of copper(II in natural water samples with sampling rate of 4 h−1.

  19. Radio weak lensing shear measurement in the visibility domain - II. Source extraction

    Rivi, M.; Miller, L.

    2018-05-01

    This paper extends the method introduced in Rivi et al. (2016b) to measure galaxy ellipticities in the visibility domain for radio weak lensing surveys. In that paper, we focused on the development and testing of the method for the simple case of individual galaxies located at the phase centre, and proposed to extend it to the realistic case of many sources in the field of view by isolating visibilities of each source with a faceting technique. In this second paper, we present a detailed algorithm for source extraction in the visibility domain and show its effectiveness as a function of the source number density by running simulations of SKA1-MID observations in the band 950-1150 MHz and comparing original and measured values of galaxies' ellipticities. Shear measurements from a realistic population of 104 galaxies randomly located in a field of view of 1 \\deg ^2 (i.e. the source density expected for the current radio weak lensing survey proposal with SKA1) are also performed. At SNR ≥ 10, the multiplicative bias is only a factor 1.5 worse than what found when analysing individual sources, and is still comparable to the bias values reported for similar measurement methods at optical wavelengths. The additive bias is unchanged from the case of individual sources, but it is significantly larger than typically found in optical surveys. This bias depends on the shape of the uv coverage and we suggest that a uv-plane weighting scheme to produce a more isotropic shape could reduce and control additive bias.

  20. Market Analysis and Consumer Impacts Source Document. Part II. Review of Motor Vehicle Market and Consumer Expenditures on Motor Vehicle Transportation

    1980-12-01

    This source document on motor vehicle market analysis and consumer impacts consists of three parts. Part II consists of studies and review on: motor vehicle sales trends; motor vehicle fleet life and fleet composition; car buying patterns of the busi...

  1. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy

    Heisterberg, Maria V; Andersen, Klaus E; Avnstorp, Christian

    2010-01-01

    Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens.......Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens....

  2. Selective and sensitive fluorescence-shift probes based on two dansyl groups for mercury(ii) ion detection.

    Ma, Li-Jun; Liu, Jialun; Deng, Lefang; Zhao, Meili; Deng, Zhifu; Li, Xutian; Tang, Jian; Yang, Liting

    2014-11-01

    Two probes ( and ) bearing two dansyl fluorophores were synthesized and applied to the detection of mercury(ii) ions in aqueous solution. These probes exhibited a selective response to Hg(2+) in a buffered solution, with high sensitivity and a unique fluorescence response signal which displayed a blue-shift effect in the fluorescence emission peak. The Hg(2+) recognition mechanisms of the probes were determined by NMR spectroscopy, ESI-MS and UV-vis spectroscopy. The results showed that probe and mercury(ii) ions formed an unusual 2:2 stoichiometric ratio complex, while probe and Hg(2+) formed a multidentate complex with a stoichiometric ratio of 2:1.

  3. Development of the detection technology of the source area derived from nuclear activities

    Suh, Kyungsuk; Kim, Ingyu; Keum, Dongkwon; Lim, Kwangmuk; Lee, Jinyong

    2012-07-01

    - It is necessary to establish of the overall preparedness for analysis of the nuclear activities near the neighboring countries by increasing of the construction of the nuclear power plants and reprocessing facilities in China, North Korean Japan and Russia. - In Korea, the analysis and measurements for nuclear activities have been conducted, however the detection technology to find out the source area has not been developed. It is important to estimate the source origin of the radioisotope from the neighboring countries including Korea in the aspects of the surveillance and safety for the covert nuclear activities in Northeast Asia region - In this study, the data DB, treatment of the weather data and the development of connection module were conducted to track the origin of the radioisotope in the first year of the research. It had constructed the DB like the reactor types, places in China, Taiwan, Japan and Korea and the release amounts of the noble gas released into the air

  4. Development of the detection technology of the source area derived from nuclear activities

    Suh, Kyungsuk; Kim, Ingyu; Keum, Dongkwon; Lim, Kwangmuk; Lee, Jinyong

    2012-07-15

    - It is necessary to establish of the overall preparedness for analysis of the nuclear activities near the neighboring countries by increasing of the construction of the nuclear power plants and reprocessing facilities in China, North Korean Japan and Russia. - In Korea, the analysis and measurements for nuclear activities have been conducted, however the detection technology to find out the source area has not been developed. It is important to estimate the source origin of the radioisotope from the neighboring countries including Korea in the aspects of the surveillance and safety for the covert nuclear activities in Northeast Asia region - In this study, the data DB, treatment of the weather data and the development of connection module were conducted to track the origin of the radioisotope in the first year of the research. It had constructed the DB like the reactor types, places in China, Taiwan, Japan and Korea and the release amounts of the noble gas released into the air.

  5. Using an alternate light source to detect electrically singed feathers and hair in a forensic setting.

    Viner, Tabitha C; Kagan, Rebecca A; Johnson, Jennifer L

    2014-01-01

    Mortality due to electrical injury in wildlife may occur in the form of lightning strike or power line contact. Evidence of electrical contact may be grossly obvious, with extensive singeing, curling, and blackening of feathers, fur, or skin. Occasionally, changes may be subtle, owing to lower current or reduced conductivity, making a definitive diagnosis of electrocution more difficult. We describe the use of an alternate light source in the examination of cases of lightning strike and power line contact in wildlife, and the enhanced detection of changes due to electrical currents in the hair and feathers of affected animals. Subtle changes in the wing feathers of 12 snow geese and 1 wolf that were struck by separate lightning events were made obvious by the use of an alternate light source. Similarly, this technique can be used to strengthen the evidence for power line exposure in birds. Published by Elsevier Ireland Ltd.

  6. Molecular detection of Fasciola hepatica in water sources of District Nowshehra Khyber Pakhtunkhwa Pakistan

    Khan, Imran; Khan, Amir Muhammad; Ayaz, Khan, Sanaullah; Anees, Muhammad; Khan, Shaukat Ali

    2012-12-01

    Fascioliasis is spread through contamination of water sources and cause morbidity throughout the world. In the current study 300 water samples were processed by PCR for detection of Fasciola hepatica. The overall prevalence in different water sources was 9.66 % (29/300). Highest prevalence was recorded in drain water16 % (16/100) followed by tube well water 10% (4/40), open well water 8 % (8/100) and the lowest was recorded in tap water 1.66 %(1/60). The significant difference P < 0.05 was recorded during data analysis. The highest prevalence was recorded in summer. It was concluded from the study that cleaning and filtration should be adopted to avoid the health hazards against water borne zoonotic parasites.

  7. Detection of Nuclear Sources by UAV Teleoperation Using a Visuo-Haptic Augmented Reality Interface

    Jacopo Aleotti

    2017-09-01

    Full Text Available A visuo-haptic augmented reality (VHAR interface is presented enabling an operator to teleoperate an unmanned aerial vehicle (UAV equipped with a custom CdZnTe-based spectroscopic gamma-ray detector in outdoor environments. The task is to localize nuclear radiation sources, whose location is unknown to the user, without the close exposure of the operator. The developed detector also enables identification of the localized nuclear sources. The aim of the VHAR interface is to increase the situation awareness of the operator. The user teleoperates the UAV using a 3DOF haptic device that provides an attractive force feedback around the location of the most intense detected radiation source. Moreover, a fixed camera on the ground observes the environment where the UAV is flying. A 3D augmented reality scene is displayed on a computer screen accessible to the operator. Multiple types of graphical overlays are shown, including sensor data acquired by the nuclear radiation detector, a virtual cursor that tracks the UAV and geographical information, such as buildings. Experiments performed in a real environment are reported using an intense nuclear source.

  8. Detection of Nuclear Sources by UAV Teleoperation Using a Visuo-Haptic Augmented Reality Interface.

    Aleotti, Jacopo; Micconi, Giorgio; Caselli, Stefano; Benassi, Giacomo; Zambelli, Nicola; Bettelli, Manuele; Zappettini, Andrea

    2017-09-29

    A visuo-haptic augmented reality (VHAR) interface is presented enabling an operator to teleoperate an unmanned aerial vehicle (UAV) equipped with a custom CdZnTe-based spectroscopic gamma-ray detector in outdoor environments. The task is to localize nuclear radiation sources, whose location is unknown to the user, without the close exposure of the operator. The developed detector also enables identification of the localized nuclear sources. The aim of the VHAR interface is to increase the situation awareness of the operator. The user teleoperates the UAV using a 3DOF haptic device that provides an attractive force feedback around the location of the most intense detected radiation source. Moreover, a fixed camera on the ground observes the environment where the UAV is flying. A 3D augmented reality scene is displayed on a computer screen accessible to the operator. Multiple types of graphical overlays are shown, including sensor data acquired by the nuclear radiation detector, a virtual cursor that tracks the UAV and geographical information, such as buildings. Experiments performed in a real environment are reported using an intense nuclear source.

  9. Design and construction of tank robot for detection and searching of radiation sources

    Rio Isman; Djiwo Harsono; Adi Abimanyu

    2016-01-01

    Developments of robotics technology can be implemented for searching the lost radiation source. Radiation source lost case allows the radiation dose exceeding NBD received by radiation worker when security precautions are taken. This research propose a robot tank that can help in detection and searching radiation sources. The robot consists of a micro controller board Arduino Mega 2560, XBee Pro S radio frequency modules, Gaps receiver U-B lox Neo-Mn-0-01, a servo motor and two DC motors. In this research, the amount of radiation is calculated in 0-5 volt analog voltage that is simulated using a potentiometer and then converted to a digital voltage value (0-1023) using ADC 10 bit Arduino Mega 2560. Results of the research show that the robot has a size of 28.7 cm x 24.8 cm x 11 cm, able to move forward with a speed of 0.477 m/s and are capable to rotate in 24 angles. Data transmission can be performed wireless up to 113 m in an open area without any changes of format and length of the data. Robot capable to rotate and move towards the angle which has the largest voltage readings so can predict the location of the radiation source. (author)

  10. Motion of the sources for type II and type IV radio bursts and flare-associated interplanetary disturbances

    Sakurai, K.; Chao, J. K.

    1974-01-01

    Shock waves are indirectly observed as the source of type II radio bursts, whereas magnetic bottles are identified as the source of moving metric type IV radio bursts. The difference between the expansion speeds of these waves and bottles is examined during their generation and propagation near the flare regions. It is shown that, although generated in the explosive phase of flares, the bottles behave quite differently from the waves and that the bottles are generally much slower than the waves. It has been suggested that the waves are related to flare-associated interplanetary disturbances which produce SSC geomagnetic storms. These disturbances may, therefore, be identified as interplanetary shock waves. The relationship among magnetic bottles, shock waves near the sun, and flare-associated disturbances in interplanetary space is briefly discussed.

  11. CERN Web Application Detection. Refactoring and release as open source software

    Lizonczyk, Piotr

    2015-01-01

    This paper covers my work during my assignment as participant of CERN Summer Students 2015 programme. The project was aimed at refactoring and publication of the Web Application Detection tool, which was developed at CERN and priorly used internally by the Computer Security team. The range of tasks performed include initial refactoring of code, which was developed like a script rather than a Python package, through extracting components that were not specific to CERN usage, the subsequent final release of the source code on GitHub and the integration with third-party software i.e. the w3af tool. Ultimately, Web Application Detection software received positive responses, being downloaded ca. 1500 times at the time of writing this report.

  12. Neutron stars as X-ray burst sources. II. Burst energy histograms and why they burst

    Baan, W.A.

    1979-01-01

    In this work we explore some of the implications of a model for X-ray burst sources where bursts are caused by Kruskal-Schwarzschild instabilities at the magnetopause of an accreting and rotating neutron star. A number of simplifying assumptions are made in order to test the model using observed burst-energy histograms for the rapid burster MXB 1730--335. The predicted histograms have a correct general shape, but it appears that other effects are important as well, and that mode competition, for instance, may suppress the histograms at high burst energies. An explanation is ventured for the enhancement in the histogram at the highest burst energies, which produces the bimodal shape in high accretion rate histograms. Quantitative criteria are given for deciding when accreting neutron stars are steady sources or burst sources, and these criteria are tested using the X-ray pulsars

  13. Detection of air pollution sources in Israel by isotope-induced XRF

    Boazi, M.; Shenberg, C.

    1978-01-01

    Aerosol samples from urban, industrial and traffic areas were collected and analyzed for various elements using isotope-induced XRF. A 10 mCi 241 Am annular source, enclosed in lead housing, was used to excite the K X-rays of an iodine target. A lithium drifted silicon diode (25 mm 2 area, 3.0 mm depletion depth) with a 0.125 mm beryllium window, was used for detection. The detector was coupled through a low-noise preamplifier and a linear amplifier to a 400-channel analyzer. The resolution (FWHM) for the 6.4 keV FeKsub(α) X-rays was approximately 180 eV. The correlation between the multielement content of the samples and their sources was studied. It was found necessary to analyze samples before and after ashing because, while ashing improves the peak-to-background ratio, volatile elements may be lost. Samples collected at heights of 1.5 and 15 m were found to have the same elemental composition. Samples collected on consecutive filters showed sharp elemental fractionation. An example of source identification is given for a high traffic area as compared with an area in which a large bromine plant is located. In both cases different Pb:Br ratios were observed, with high bromine concentration in the latter. The analytical method used was based on the detection of characteristic K and L X-rays induced by a 241 Am-I source-target assembly. (T.G.)

  14. The faint radio source population at 15.7 GHz - II. Multi-wavelength properties

    Whittam, I. H.; Riley, J. M.; Green, D. A.; Jarvis, M. J.; Vaccari, M.

    2015-11-01

    A complete, flux density limited sample of 96 faint (>0.5 mJy) radio sources is selected from the 10C survey at 15.7 GHz in the Lockman Hole. We have matched this sample to a range of multi-wavelength catalogues, including Spitzer Extragalactic Representative Volume Survey, Spitzer Wide-area Infrared Extragalactic survey, United Kingdom Infrared Telescope Infrared Deep Sky Survey and optical data; multi-wavelength counterparts are found for 80 of the 96 sources and spectroscopic redshifts are available for 24 sources. Photometric redshifts are estimated for the sources with multi-wavelength data available; the median redshift of the sample is 0.91 with an interquartile range of 0.84. Radio-to-optical ratios show that at least 94 per cent of the sample are radio loud, indicating that the 10C sample is dominated by radio galaxies. This is in contrast to samples selected at lower frequencies, where radio-quiet AGN and star-forming galaxies are present in significant numbers at these flux density levels. All six radio-quiet sources have rising radio spectra, suggesting that they are dominated by AGN emission. These results confirm the conclusions of Paper I that the faint, flat-spectrum sources which are found to dominate the 10C sample below ˜1 mJy are the cores of radio galaxies. The properties of the 10C sample are compared to the Square Kilometre Array Design Studies Simulated Skies; a population of low-redshift star-forming galaxies predicted by the simulation is not found in the observed sample.

  15. Ultrasensitive detection of pepsinogen I and pepsinogen II by a time-resolved fluoroimmunoassay and its preliminary clinical applications

    Huang Biao [Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu Province 214063 (China) and Southern Yangzi University, Wuxi, Jiangsu Province 214036 (China)]. E-mail: huangbiao78@hotmail.com; Xiao Hualong [Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu Province 214063 (China); Zhang Xiangrui [Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu Province 214063 (China); Zhu, Lan [Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu Province 214063 (China); Liu Haiyan [Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu Province 214063 (China); Jin Jian [Southern Yangzi University, Wuxi, Jiangsu Province 214036 (China)

    2006-06-30

    A fast and highly sensitive assay for pepsinogen I (PG I) and pepsinogen II (PG II) by using time-resolved fluoroimmunoassay (TRFIA) detection technique has been developed for the determination of serum PG I and PG II against gastrointestinal diseases. On the noncompetitive assay, one monoclonal antibody (McAb) coated on wells was directed against a specific antigenic site on the PG I or PG II. The McAb, called as labelling McAb, was prepared with the europium-chelate of N-(p-isothiocyanatobenzyl)-diethylenetriamine-N,N,N,N-tetraacetic acid and directed against a different antigenic site on the PG I or PG II molecule. After bound/free separation by washing, the fluorescence counts of bound Eu{sup 3+}-McAb were measured. The levels of PG in sera from patients or healthy volunteers were determined by PG I and PG II TRFIA using the autoDELFIA{sub 1235} system. The measurement ranges of PG I-TRFIA were 3.5-328.0 {mu}g L{sup -1} and those of PG II-TRFIA were 2.0-55.0 {mu}g L{sup -1}. The within-run and between-run CVs of the PG I-TRFIA were 1.9% and 4.7%, respectively, and those of PG II-TRFIA were 2.1% and 3.8%, respectively. The recovery rates of PG I-TRFIA and PG II-TRFIA were 102.7% and 104.6%, respectively. The detection limitations of PG I and PG II were 0.05 {mu}g L{sup -1} and 0.02 {mu}g L{sup -1}, respectively. The dilution experiments showed the percentage of expected value of PG I-TRFIA was 93.2-102.3% and of PG II-TRFIA was 97.3-110.6%. The cross-reacting rate between PG I and PG II was negligible. The linear correlation of radioimmunoassay (RIA) and TRFIA measurements resulted in a correlation coefficient as 0.926 of PG I and as 0.959 of PG II. The europium-labelling McAbs were stable for at least one year at -20 deg. C, and the results of the TRFIA with same reagents were reproducible over one year as well. The means of 1600 healthy volunteers were 162.4 {+-} 52.1 {mu}g L{sup -1} for serum PG I, 11.7 {+-} 6.8 {mu}g L{sup -1} for serum PG II, and 13

  16. Single sources in the low-frequency gravitational wave sky: properties and time to detection by pulsar timing arrays

    Kelley, Luke Zoltan; Blecha, Laura; Hernquist, Lars; Sesana, Alberto; Taylor, Stephen R.

    2018-06-01

    We calculate the properties, occurrence rates and detection prospects of individually resolvable `single sources' in the low-frequency gravitational wave (GW) spectrum. Our simulations use the population of galaxies and massive black hole binaries from the Illustris cosmological hydrodynamic simulations, coupled to comprehensive semi-analytic models of the binary merger process. Using mock pulsar timing arrays (PTA) with, for the first time, varying red-noise models, we calculate plausible detection prospects for GW single sources and the stochastic GW background (GWB). Contrary to previous results, we find that single sources are at least as detectable as the GW background. Using mock PTA, we find that these `foreground' sources (also `deterministic'/`continuous') are likely to be detected with ˜20 yr total observing baselines. Detection prospects, and indeed the overall properties of single sources, are only moderately sensitive to binary evolution parameters - namely eccentricity and environmental coupling, which can lead to differences of ˜5 yr in times to detection. Red noise has a stronger effect, roughly doubling the time to detection of the foreground between a white-noise only model (˜10-15 yr) and severe red noise (˜20-30 yr). The effect of red noise on the GWB is even stronger, suggesting that single source detections may be more robust. We find that typical signal-to-noise ratios for the foreground peak near f = 0.1 yr-1, and are much less sensitive to the continued addition of new pulsars to PTA.

  17. Multisource inverse-geometry CT. Part II. X-ray source design and prototype

    Neculaes, V. Bogdan, E-mail: neculaes@ge.com; Caiafa, Antonio; Cao, Yang; De Man, Bruno; Edic, Peter M.; Frutschy, Kristopher; Gunturi, Satish; Inzinna, Lou; Reynolds, Joseph; Vermilyea, Mark; Wagner, David; Zhang, Xi; Zou, Yun [GE Global Research, Niskayuna, New York 12309 (United States); Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Lounsberry, Brian [Healthcare Science Technology, GE Healthcare, West Milwaukee, Wisconsin 53219 (United States)

    2016-08-15

    Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent

  18. The Integration of Renewable Energy Sources into Electric Power Distribution Systems, Vol. II Utility Case Assessments

    Zaininger, H.W.

    1994-01-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: the local solar insolation and/or wind characteristics, renewable energy source penetration level, whether battery or other energy storage systems are applied, and local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kW-scale applications may be connected to three+phase secondaries, and larger hundred-kW and y-scale applications, such as MW-scale windfarms, or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. In any case, the installation of small, distributed renewable energy sources is expected to have a significant impact on local utility distribution primary and secondary system economics. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications. The

  19. Towards adiabatic waveforms for inspiral into Kerr black holes. II. Dynamical sources and generic orbits

    Sundararajan, Pranesh A.; Hughes, Scott A.; Khanna, Gaurav; Drasco, Steve

    2008-01-01

    This is the second in a series of papers whose aim is to generate adiabatic gravitational waveforms from the inspiral of stellar-mass compact objects into massive black holes. In earlier work, we presented an accurate (2+1)D finite-difference time-domain code to solve the Teukolsky equation, which evolves curvature perturbations near rotating (Kerr) black holes. The key new ingredient there was a simple but accurate model of the singular source term based on a discrete representation of the Dirac-delta function and its derivatives. Our earlier work was intended as a proof of concept, using simple circular, equatorial geodesic orbits as a test bed. Such a source is effectively static, in that the smaller body remains at the same coordinate radius and orbital inclination over an orbit. (It of course moves through axial angle, but we separate that degree of freedom from the problem. Our numerical grid has only radial, polar, and time coordinates.) We now extend the time-domain code so that it can accommodate dynamic sources that move on a variety of physically interesting world lines. We validate the code with extensive comparison to frequency-domain waveforms for cases in which the source moves along generic (inclined and eccentric) bound geodesic orbits. We also demonstrate the ability of the time-domain code to accommodate sources moving on interesting nongeodesic worldlines. We do this by computing the waveform produced by a test mass following a kludged inspiral trajectory, made of bound geodesic segments driven toward merger by an approximate radiation loss formula.

  20. Immobilized Tannin from Sanseviera trifasciata on Carbon as Adsorbent For Iron(II in Polluted Water Source

    Irfan Hanafi Arif

    2016-03-01

    Full Text Available The organic-agricultural waste resulted from local farmer or community gardening recently paid public attention. The presence and easily grown of “Lidah Mertua” or Sanseviera trifasciata being focused on potency investigation for its prospecting application. It was reported contain some phenolic and also tannin extracted from aqueous solvents. This paper revealed recent investigation applying of its isolated tannin from leave part to modifying of activated carbon. The previous report published that carbon were able to adsorb some toxic heavy metals. However, it has some limitation including lower capacity adsorption. Impregnated or immobilized the tannin-isolated from S. trifasciata leaves was able to modify the carbon functionality, physical appearance, pores size, and it adsorption capacity. Both Langmuir and Freundlich adsorption mechanism model also disclosed the developed adsorbent mechanism of iron(II adsorption on the adsorbent tannin-immobolized on carbon. The real test using community well drilling water source also gave important finding on the concentration of iron(II contained on water source.

  1. High sensitive detection of copper II ions using D-penicillamine-coated gold nanorods based on localized surface plasmon resonance

    Hong, Yoochan; Jo, Seongjae; Park, Joohyung; Park, Jinsung; Yang, Jaemoon

    2018-05-01

    In this paper, we describe the development of a nanoplasmonic biosensor based on the localized surface plasmon resonance (LSPR) effect that enables a sensitive and selective recognition of copper II ions. First, we fabricated the nanoplasmonics as LSPR substrates using gold nanorods (GNR) and the nano-adsorption method. The LSPR sensitivity of the nanoplasmonics was evaluated using various solvents with different refractive indexes. Subsequently, D-penicillamine (DPA)—a chelating agent of copper II ions—was conjugated to the surface of the GNR. The limit of detection (LOD) for the DPA-conjugated nanoplasmonics was 100 pM. Furthermore, selectivity tests were conducted using various divalent cations, and sensitivity tests were conducted on the nanoplasmonics under blood-like environments. Finally, the developed nanoplasmonic biosensor based on GNR shows great potential for the effective recognition of copper II ions, even in human blood conditions.

  2. Linear feature detection algorithm for astronomical surveys - II. Defocusing effects on meteor tracks

    Bektešević, Dino; Vinković, Dejan; Rasmussen, Andrew; Ivezić, Željko

    2018-03-01

    Given the current limited knowledge of meteor plasma micro-physics and its interaction with the surrounding atmosphere and ionosphere, meteors are a highly interesting observational target for high-resolution wide-field astronomical surveys. Such surveys are capable of resolving the physical size of meteor plasma heads, but they produce large volumes of images that need to be automatically inspected for possible existence of long linear features produced by meteors. Here, we show how big aperture sky survey telescopes detect meteors as defocused tracks with a central brightness depression. We derive an analytic expression for a defocused point source meteor track and use it to calculate brightness profiles of meteors modelled as uniform brightness discs. We apply our modelling to meteor images as seen by the Sloan Digital Sky Survey and Large Synoptic Survey Telescope telescopes. The expression is validated by Monte Carlo ray-tracing simulations of photons travelling through the atmosphere and the Large Synoptic Survey Telescope telescope optics. We show that estimates of the meteor distance and size can be extracted from the measured full width at half-maximum and the strength of the central dip in the observed brightness profile. However, this extraction becomes difficult when the defocused meteor track is distorted by the atmospheric seeing or contaminated by a long-lasting glowing meteor trail. The full width at half-maximum of satellite tracks is distinctly narrower than meteor values, which enables removal of a possible confusion between satellites and meteors.

  3. TANAMI: Tracking Active Galactic Nuclei with Austral Milliarcsecond Interferometry. II. Additional sources

    Müller, C.; Kadler, M.; Ojha, R.; Schulz, R.; Trüstedt, J.; Edwards, P. G.; Ros, E.; Carpenter, B.; Angioni, R.; Blanchard, J.; Böck, M.; Burd, P. R.; Dörr, M.; Dutka, M. S.; Eberl, T.; Gulyaev, S.; Hase, H.; Horiuchi, S.; Katz, U.; Krauß, F.; Lovell, J. E. J.; Natusch, T.; Nesci, R.; Phillips, C.; Plötz, C.; Pursimo, T.; Quick, J. F. H.; Stevens, J.; Thompson, D. J.; Tingay, S. J.; Tzioumis, A. K.; Weston, S.; Wilms, J.; Zensus, J. A.

    2018-02-01

    Context. TANAMI is a multiwavelength program monitoring active galactic nuclei (AGN) south of - 30° declination including high-resolution very long baseline interferometry (VLBI) imaging, radio, optical/UV, X-ray, and γ-ray studies. We have previously published first-epoch8.4 GHz VLBI images of the parsec-scale structure of the initial sample. In this paper, we present images of 39 additional sources. The full sample comprises most of the radio- and γ-ray brightest AGN in the southern quarter of the sky, overlapping with the region from which high-energy (> 100 TeV) neutrino events have been found. Aims: We characterize the parsec-scale radio properties of the jets and compare them with the quasi-simultaneous Fermi/LAT γ-ray data. Furthermore, we study the jet properties of sources which are in positional coincidence with high-energy neutrino events compared to the full sample. We test the positional agreement of high-energy neutrino events with various AGN samples. Methods: TANAMI VLBI observations at 8.4 GHz are made with southern hemisphere radio telescopes located in Australia, Antarctica, Chile, New Zealand, and South Africa. Results: Our observations yield the first images of many jets below - 30° declination at milliarcsecond resolution. We find that γ-ray loud TANAMI sources tend to be more compact on parsec-scales and have higher core brightness temperatures than γ-ray faint jets, indicating higher Doppler factors. No significant structural difference is found between sources in positional coincidence with high-energy neutrino events and other TANAMI jets. The 22 γ-ray brightest AGN in the TANAMI sky show only a weak positional agreement with high-energy neutrinos demonstrating that the > 100 TeV IceCube signal is not simply dominated by a small number of the γ-ray brightest blazars. Instead, a larger number of sources have to contribute to the signal with each individual source having only a small Poisson probability for producing an event in

  4. Detection of pulmonary nodules at paediatric CT: maximum intensity projections and axial source images are complementary

    Kilburn-Toppin, Fleur; Arthurs, Owen J.; Tasker, Angela D.; Set, Patricia A.K.

    2013-01-01

    Maximum intensity projection (MIP) images might be useful in helping to differentiate small pulmonary nodules from adjacent vessels on thoracic multidetector CT (MDCT). The aim was to evaluate the benefits of axial MIP images over axial source images for the paediatric chest in an interobserver variability study. We included 46 children with extra-pulmonary solid organ malignancy who had undergone thoracic MDCT. Three radiologists independently read 2-mm axial and 10-mm MIP image datasets, recording the number of nodules, size and location, overall time taken and confidence. There were 83 nodules (249 total reads among three readers) in 46 children (mean age 10.4 ± 4.98 years, range 0.3-15.9 years; 24 boys). Consensus read was used as the reference standard. Overall, three readers recorded significantly more nodules on MIP images (228 vs. 174; P < 0.05), improving sensitivity from 67% to 77.5% (P < 0.05) but with lower positive predictive value (96% vs. 85%, P < 0.005). MIP images took significantly less time to read (71.6 ± 43.7 s vs. 92.9 ± 48.7 s; P < 0.005) but did not improve confidence levels. Using 10-mm axial MIP images for nodule detection in the paediatric chest enhances diagnostic performance, improving sensitivity and reducing reading time when compared with conventional axial thin-slice images. Axial MIP and axial source images are complementary in thoracic nodule detection. (orig.)

  5. Sensitive detection of biothiols and histidine based on the recovered fluorescence of the carbon quantum dots–Hg(II) system

    Hou, Juan; Zhang, Fengshuang; Yan, Xu; Wang, Long; Yan, Jin [College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012 (China); Ding, Hong [State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China); Ding, Lan, E-mail: dinglan@jlu.edu.cn [College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012 (China)

    2015-02-15

    Highlights: • Carbon quantum dots-based probe was used for detection of GSH, Cys or His. • The fluorescence of CQDs was quenched by Hg(II) and then recovered by GSH, Cys or His. • No further surface modification or purification of CQDs was required. • This sensor exhibits superior accuracy and sensitivity. • The proposed method was simple in design, fast in operation. - Abstract: In this paper, we presented a novel, rapid and highly sensitive sensor for glutathione (GSH), cysteine (Cys) and histidine (His) based on the recovered fluorescence of the carbon quantum dots (CQDs)–Hg(II) system. The CQDs were synthesized by microwave-assisted approach in one pot according to our previous report. The fluorescence of CQDs could be quenched in the presence of Hg(II) due to the coordination occurring between Hg(II) and functional groups on the surface of CQDs. Subsequently, the fluorescence of the CQDs–Hg(II) system was recovered gradually with the addition of GSH, Cys or His due to their stronger affinity with Hg(II). A good linear relationship was obtained from 0.10 to 20 μmol L{sup −1} for GSH, from 0.20 to 45 μmol L{sup −1} for Cys and from 0.50 to 60 μmol L{sup −1} for His, respectively. This method has been successfully applied to the trace detection of GSH, Cys or His in human serum samples with satisfactory results. The proposed method was simple in design and fast in operation, which demonstrated great potential in bio-sensing fields.

  6. Sensitive detection of biothiols and histidine based on the recovered fluorescence of the carbon quantum dots–Hg(II) system

    Hou, Juan; Zhang, Fengshuang; Yan, Xu; Wang, Long; Yan, Jin; Ding, Hong; Ding, Lan

    2015-01-01

    Highlights: • Carbon quantum dots-based probe was used for detection of GSH, Cys or His. • The fluorescence of CQDs was quenched by Hg(II) and then recovered by GSH, Cys or His. • No further surface modification or purification of CQDs was required. • This sensor exhibits superior accuracy and sensitivity. • The proposed method was simple in design, fast in operation. - Abstract: In this paper, we presented a novel, rapid and highly sensitive sensor for glutathione (GSH), cysteine (Cys) and histidine (His) based on the recovered fluorescence of the carbon quantum dots (CQDs)–Hg(II) system. The CQDs were synthesized by microwave-assisted approach in one pot according to our previous report. The fluorescence of CQDs could be quenched in the presence of Hg(II) due to the coordination occurring between Hg(II) and functional groups on the surface of CQDs. Subsequently, the fluorescence of the CQDs–Hg(II) system was recovered gradually with the addition of GSH, Cys or His due to their stronger affinity with Hg(II). A good linear relationship was obtained from 0.10 to 20 μmol L −1 for GSH, from 0.20 to 45 μmol L −1 for Cys and from 0.50 to 60 μmol L −1 for His, respectively. This method has been successfully applied to the trace detection of GSH, Cys or His in human serum samples with satisfactory results. The proposed method was simple in design and fast in operation, which demonstrated great potential in bio-sensing fields

  7. Catalog of physical protection equipment. Book 1: Volume II. Intrusion detection components

    Haberman, W.

    1977-06-01

    This volume covers acoustic components, microwave/radar components, electro-optic barriers, electric field components, orientation components, ferrous metal detection components, proximity detection components, vibration detection components, seismic components, pressure-sensitive components, pressure mats, continuity components, electrical/magnetic switches, fire detection components, and mechanical contact switches

  8. Alpha spectrometry of thick sources. II. Application to the study of radioactive equilibria in uranium ores

    Acena Barrenechea, M.L.; Tormo Ferrero, M.J.

    1977-01-01

    A method for determining nuclide activities in 4n + 2 uranium series using alpha spectrometry of thick sources is described. This method has been applied to several uranium ores, showing different states of radioactive equilibria. The spectra from samples prepared by cold compression show some anomalies, due to the evolution and later decay of 219 Rn and daughters. This phenomenon must be taken in consideration when computing spectra line intensities. (author) [es

  9. Detection of Second Sound in He-II for Thermal Quench Mapping of Superconducting Radio Frequency Accelerating Cavities

    Stegmaier, Tobias; Kind, Matthias; Furci, Hernán; Koettig, Torsten; Peters, Benedikt

    The development of future particle accelerators requires intensive testing of superconducting radio frequency cavities with different sizes and geometries. Non-contact thermometry quench localisation techniques proved to be beneficial for the localisation of surface defects that can originate a quench (sudden loss of superconducting state). These techniques are based on the detection of second sound in helium II. Transition Edge Sensors (TES) are highly sensitive thin film thermometers with fast time response. In the present work, their capability as a thermal quench mapping device for superconducting radio frequency cavities is proven experimentally by detecting second sound waves emitted by SMD heaters in a He-II bath at saturated vapour pressure. A characterisation of the sensors at steady bath temperatures was conducted to calculate the thermal sensitivity. An intense metallurgical study of gold-tin TES with different compositions revealed important relations between the superconducting behaviour and the ...

  10. Nasu 1.4 GHz Interferometer Transient Radio Source Survey and Improvement in Detection of Radio Sources

    Matsumura, Nobuo; Kuniyoshi, Masaya; Takefuji, Kazuhiro; Niinuma, Kotaro; Kida, Sumiko; Takeuchi, Akihiko; Asuma, Kuniyuki; Daishido, Tsuneaki

    2006-01-01

    We have surveyed 1.4GHz transient radio sources in Nasu Pulsar Observatory. To investigate such sources, both immediacy and accuracy are severely maintained. We have developed Data Transfer System and improved antenna control system. Now we have received the fringe data from transient radio source candidates. To get reliable information, we carefully analyze with Fringe Band Pass Filter software and Fringe Fitting method

  11. Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection.

    Weisenthal, Samuel J; Folio, Les; Kovacs, William; Seff, Ari; Derderian, Vana; Summers, Ronald M; Yao, Jianhua

    2016-08-01

    We present an open-source, picture archiving and communication system (PACS)-integrated radiation exposure extraction engine (RE3) that provides study-, series-, and slice-specific data for automated monitoring of computed tomography (CT) radiation exposure. RE3 was built using open-source components and seamlessly integrates with the PACS. RE3 calculations of dose length product (DLP) from the Digital imaging and communications in medicine (DICOM) headers showed high agreement (R (2) = 0.99) with the vendor dose pages. For study-specific outlier detection, RE3 constructs robust, automatically updating multivariable regression models to predict DLP in the context of patient gender and age, scan length, water-equivalent diameter (D w), and scanned body volume (SBV). As proof of concept, the model was trained on 811 CT chest, abdomen + pelvis (CAP) exams and 29 outliers were detected. The continuous variables used in the outlier detection model were scan length (R (2)  = 0.45), D w (R (2) = 0.70), SBV (R (2) = 0.80), and age (R (2) = 0.01). The categorical variables were gender (male average 1182.7 ± 26.3 and female 1047.1 ± 26.9 mGy cm) and pediatric status (pediatric average 710.7 ± 73.6 mGy cm and adult 1134.5 ± 19.3 mGy cm).

  12. Detecting and analyzing soil phosphorus loss associated with critical source areas using a remote sensing approach.

    Lou, Hezhen; Yang, Shengtian; Zhao, Changsen; Shi, Liuhua; Wu, Linna; Wang, Yue; Wang, Zhiwei

    2016-12-15

    The detection of critical source areas (CSAs) is a key step in managing soil phosphorus (P) loss and preventing the long-term eutrophication of water bodies at regional scale. Most related studies, however, focus on a local scale, which prevents a clear understanding of the spatial distribution of CSAs for soil P loss at regional scale. Moreover, the continual, long-term variation in CSAs was scarcely reported. It is impossible to identify the factors driving the variation in CSAs, or to collect land surface information essential for CSAs detection, by merely using the conventional methodologies at regional scale. This study proposes a new regional-scale approach, based on three satellite sensors (ASTER, TM/ETM and MODIS), that were implemented successfully to detect CSAs at regional scale over 15years (2000-2014). The approach incorporated five factors (precipitation, slope, soil erosion, land use, soil total phosphorus) that drive soil P loss from CSAs. Results show that the average area of critical phosphorus source areas (CPSAs) was 15,056km 2 over the 15-year period, and it occupied 13.8% of the total area, with a range varying from 1.2% to 23.0%, in a representative, intensive agricultural area of China. In contrast to previous studies, we found that the locations of CSAs with P loss are spatially variable, and are more dispersed in their distribution over the long term. We also found that precipitation acts as a key driving factor in the variation of CSAs at regional scale. The regional-scale method can provide scientific guidance for managing soil phosphorus loss and preventing the long-term eutrophication of water bodies at regional scale, and shows great potential for exploring factors that drive the variation in CSAs at global scale. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Detection of embedded radiation sources using temporal variation of gamma spectral data.

    Shokair, Isaac R.

    2011-09-01

    Conventional full spectrum gamma spectroscopic analysis has the objective of quantitative identification of all the isotopes present in a measurement. For low energy resolution detectors, when photopeaks alone are not sufficient for complete isotopic identification, such analysis requires template spectra for all the isotopes present in the measurement. When many isotopes are present it is difficult to make the correct identification and this process often requires many trial solutions by highly skilled spectroscopists. This report investigates the potential of a new analysis method which uses spatial/temporal information from multiple low energy resolution measurements to test the hypothesis of the presence of a target spectrum of interest in these measurements without the need to identify all the other isotopes present. This method is referred to as targeted principal component analysis (TPCA). For radiation portal monitor applications, multiple measurements of gamma spectra are taken at equally spaced time increments as a vehicle passes through the portal and the TPCA method is directly applicable to this type of measurement. In this report we describe the method and investigate its application to the problem of detection of a radioactive localized source that is embedded in a distributed source in the presence of an ambient background. Examples using simulated spectral measurements indicate that this method works very well and has the potential for automated analysis for RPM applications. This method is also expected to work well for isotopic detection in the presence of spectrally and spatially varying backgrounds as a result of vehicle-induced background suppression. Further work is needed to include effects of shielding, to understand detection limits, setting of thresholds, and to estimate false positive probability.

  14. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy

    Heisterberg, Maria S Vølund; Andersen, Klaus E.; Avnstorp, Christian

    2010-01-01

    Background: Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens. Aim......: To investigate the diagnostic contribution of including FM II in the baseline series by comparing it with other screening markers of fragrance allergy: fragrance mix I (FM I), Myroxylon pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC). Method: Retrospective study of 12 302 patients consecutively...

  15. A novel method for detecting light source for digital images forensic

    Roy, A. K.; Mitra, S. K.; Agrawal, R.

    2011-06-01

    Manipulation in image has been in practice since centuries. These manipulated images are intended to alter facts — facts of ethics, morality, politics, sex, celebrity or chaos. Image forensic science is used to detect these manipulations in a digital image. There are several standard ways to analyze an image for manipulation. Each one has some limitation. Also very rarely any method tried to capitalize on the way image was taken by the camera. We propose a new method that is based on light and its shade as light and shade are the fundamental input resources that may carry all the information of the image. The proposed method measures the direction of light source and uses the light based technique for identification of any intentional partial manipulation in the said digital image. The method is tested for known manipulated images to correctly identify the light sources. The light source of an image is measured in terms of angle. The experimental results show the robustness of the methodology.

  16. Particle Filter with Integrated Voice Activity Detection for Acoustic Source Tracking

    Anders M. Johansson

    2007-01-01

    Full Text Available In noisy and reverberant environments, the problem of acoustic source localisation and tracking (ASLT using an array of microphones presents a number of challenging difficulties. One of the main issues when considering real-world situations involving human speakers is the temporally discontinuous nature of speech signals: the presence of silence gaps in the speech can easily misguide the tracking algorithm, even in practical environments with low to moderate noise and reverberation levels. A natural extension of currently available sound source tracking algorithms is the integration of a voice activity detection (VAD scheme. We describe a new ASLT algorithm based on a particle filtering (PF approach, where VAD measurements are fused within the statistical framework of the PF implementation. Tracking accuracy results for the proposed method is presented on the basis of synthetic audio samples generated with the image method, whereas performance results obtained with a real-time implementation of the algorithm, and using real audio data recorded in a reverberant room, are published elsewhere. Compared to a previously proposed PF algorithm, the experimental results demonstrate the improved robustness of the method described in this work when tracking sources emitting real-world speech signals, which typically involve significant silence gaps between utterances.

  17. Detection of Second Sound in He-II for Thermal Quench Mapping of Superconducting Radio Frequency Accelerating Cavities

    Stegmaier, Tobias; Grohmann, Steffen; Kind, Matthias; Furci, Hernán; Koettig, Torsten; Peters, Benedikt

    2018-01-01

    The development of future particle accelerators requires intensive testing of superconducting radio frequency cavities with different sizes and geometries. Non-contact thermometry quench localisation techniques proved to be beneficial for the localisation of surface defects that can originate a quench (sudden loss of superconducting state). These techniques are based on the detection of second sound in helium II. Transition Edge Sensors (TES) are highly sensitive thin film thermometers with f...

  18. Phase II: Automated System for Aneuploidy Detection in Sperm Final Report CRADA No. TC-1554-98

    Wyrobek, W. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dunlay, R. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-28

    This was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and Cellomics, Inc. (formerly BioDx and Biological Detection, Inc.) to develop an automated system for detecting human sperm aneuploidy. Aneuploidy (an abnormal number of chromosomes) is one of the major categories of chromosomally abnormal sperm, which results in chromosomally defective pregnancies and babies. An automated system would be used for testing the effects of toxic agents and for other research and clinical applications. This collaborated effort was funded by a National Institutes of Environmental Health Services, Phase II, Small Business Innovation Research Program (SBIR) grant to Cellornics (Contract No. N44-ES-82004).

  19. Application of leftover sample material from waterborne protozoa monitoring for the molecular detection of Bacteroidales and fecal source tracking markers

    In this study, we examined the potential for detecting fecal bacteria and microbial source tracking markers in samples discarded during the concentration of Cryptosporidium and Giardia using USEPA Method 1623. Recovery rates for different fecal bacteria were determined using sp...

  20. The repeatability of three diagnostic methods (visual using ICDAS II, laser fluorescence, and radiographic) for early caries detection

    Sukmasari, S.; Lestari, W.; Ko, B. B.; Noh, Z.; Asmail, N.; Yaacob, N.

    2017-08-01

    Newly introduced ICDAS II as a visual method, laser fluorescence as another technique that have ability to quantify early mineral loss of tooth structure and intra oral radiograph, are methods can be used in the clinic. To provide standardization for comprehensive caries management at an early stage, all methods supposed to be tested between users. The objective of this research is to evaluate the repeatability of each system. It is a comparative cross sectional study using 100 extracted permanent teeth without obvious cavitation (premolar & molar) that were collected and stored in thymol solution. The teeth were embedded on the wax block and labeled with numbers. All 5 surfaces were examined by 5 examiners using visual (ICDAS II), laser fluorescence (LF) and radiographic examination. The data were then analyzed to measure intra and inter examiner repeatability using Cronbach’s alpha and inter-item correlation matrix. Intra-examiner repeatability for all examiners was >0.7. Chronbach’s a value for inter-examiner repeatability for ICDAS II was >0.8 on 3 surfaces except on buccal and lingual. LF exhibit repeatability of >0.8 on all surfaces. Radiograph shows a low value of inter examiner repeatability (students for inter-item correlation while the 2nd and 3rd reading of LF displays the best agreement. ICDAS II score favors more non-invasive treatment compared to LF. ICDAS II showed good repeatability except on buccal and lingual surfaces. In line with some of the previous study, ICDAS II is applicable for caries detection in daily clinical basis. Laser fluorescence exhibits the highest repeatability while the radiograph showed weak inter-examiner repeatability. Treatment decisions of ICDAS II propose more preventive treatment for early caries lesions compared to laser fluorescence.

  1. Strong copper(II) species in estuarine and sea waters investigated by a method with high detection window.

    Alberti, Giancarla; Biesuz, Raffaela; D'Agostino, Girolamo; Scarponi, Giuseppe; Pesavento, Maria

    2007-02-15

    The distribution of copper(II) in species of different stability in some estuarine and sea water samples (Adriatic Sea) was investigated by a method based on the sorption of the metal ion on a strongly sorbing resin, Chelex 100, whose sorbing properties have been previously characterized. From them, it is possible to predict very high values of detection windows at the considered conditions, for example side reaction coefficient as high as 10(10) at pH 7.5. Strong copper(II) species in equilibrium with Chelex 100 were detected, at concentration 2-20nM, with a reaction coefficient approximately 10(10.6) at pH 7.45 in sea water, strictly depending on the acidity. They represent 50-70% of the total metal ion and are the strongest copper(II) complexes found in sea water. Weak complexes too were detected in all the samples, with reaction coefficient lower than ca. 10(9) at the same pH. The method applied, named resin titration (RT), was described in a previous investigation, and is here modified in order to be carried out on oceanographic boat during a cruise in the Adriatic Sea.

  2. Improved photoelectrochemical detection of mercury (II) with a TiO2-modified composite photoelectrode

    Chamier, Jessica; Crouch, Andrew M.

    2012-01-01

    Highlights: • We have determined that a PANI–RS modified photoelectrode behaved as a photoanode in the presence of Hg 2+ . • The photoresponse of the ITO/TiO 2 /PANI–RS photoelectrode was equivalent to the amount of Hg 2+ in solution. • The linear range for photoelectrochemical detection of Hg 2+ was 10–200 μg L −1 Hg 2+ with a LOQ of 4 μg L −1 . • We determined that the pH independence of ITO/TiO 2 /PANI–RS photoelectrode was limit by the TiO 2 layer to between pH 6 and 7. - Abstract: The spectrophotometric change of a mercury (II) (Hg 2+ ) selective small molecule chemosensor has been successfully converted into a photovoltaic response upon ligating Hg 2+ . The photon excitation was followed by charge separation facilitated by TiO 2 and polyaniline (PANI), resulting in an electron transfer to an electrical back contact. The photoresponse of the Hg 2+ selective chromophore was converted to an electron current equivalent to the amount of Hg 2+ in solution. The favourable properties of a Hg 2+ sensitive chemosensor was combined with the semiconductor capabilities of TiO 2 to construct a sensor that is capable of generating a current in the presence of Hg 2+ under illumination. A composite of the fluorescent chemosensor rhodamine 6G hydrozone derivative (RS) and PANI was immobilized on indium tin oxide (ITO) plates coated with TiO 2 and subjected to photovoltammetric measurements. The photovoltammetric responses of the coated layers were investigated to determine the sensitivity and selectivity of the immobilized sensor to Hg 2+ in the presence of background ions. The photo-response increased linearly with increasing Hg 2+ concentration from 10 to 200 μg L −1 with a limit of quantification (LOQ) of 4 μg L −1 . The pH independence for the photoresponse was limited by the TiO 2 layer and was optimal between pH 6 and 7.

  3. Improved photoelectrochemical detection of mercury (II) with a TiO{sub 2}-modified composite photoelectrode

    Chamier, Jessica [Department of Chemistry and Polymer Science, University of Stellenbosch, Matieland X1, Stellenbosch 7602 (South Africa); Council for Scientific and Industrial Research, Natural Resources and the Environment, P.O. Box 320, Stellenbosch 7599 (South Africa); Crouch, Andrew M., E-mail: andrew.crouch@wits.ac.za [Institute of Molecular Sciences, Faculty of Science, University of the Witwatersrand, Private Bag 3, Wits, 2050, Johannesburg (South Africa)

    2012-01-16

    Highlights: Bullet We have determined that a PANI-RS modified photoelectrode behaved as a photoanode in the presence of Hg{sup 2+}. Bullet The photoresponse of the ITO/TiO{sub 2}/PANI-RS photoelectrode was equivalent to the amount of Hg{sup 2+} in solution. Bullet The linear range for photoelectrochemical detection of Hg{sup 2+} was 10-200 {mu}g L{sup -1} Hg{sup 2+} with a LOQ of 4 {mu}g L{sup -1}. Bullet We determined that the pH independence of ITO/TiO{sub 2}/PANI-RS photoelectrode was limit by the TiO{sub 2} layer to between pH 6 and 7. - Abstract: The spectrophotometric change of a mercury (II) (Hg{sup 2+}) selective small molecule chemosensor has been successfully converted into a photovoltaic response upon ligating Hg{sup 2+}. The photon excitation was followed by charge separation facilitated by TiO{sub 2} and polyaniline (PANI), resulting in an electron transfer to an electrical back contact. The photoresponse of the Hg{sup 2+} selective chromophore was converted to an electron current equivalent to the amount of Hg{sup 2+} in solution. The favourable properties of a Hg{sup 2+} sensitive chemosensor was combined with the semiconductor capabilities of TiO{sub 2} to construct a sensor that is capable of generating a current in the presence of Hg{sup 2+} under illumination. A composite of the fluorescent chemosensor rhodamine 6G hydrozone derivative (RS) and PANI was immobilized on indium tin oxide (ITO) plates coated with TiO{sub 2} and subjected to photovoltammetric measurements. The photovoltammetric responses of the coated layers were investigated to determine the sensitivity and selectivity of the immobilized sensor to Hg{sup 2+} in the presence of background ions. The photo-response increased linearly with increasing Hg{sup 2+} concentration from 10 to 200 {mu}g L{sup -1} with a limit of quantification (LOQ) of 4 {mu}g L{sup -1}. The pH independence for the photoresponse was limited by the TiO{sub 2} layer and was optimal between pH 6 and 7.

  4. On the physics of power, energy and economics of renewable electric energy sources - Part II

    Skoglund, Annika; Leijon, Mats; Waters, Rafael; Rehn, Alf; Lindahl, Marcus

    2010-01-01

    Renewable Energy Technologies (RETs) are often recognized as less competitive than traditional electric energy conversion systems. Obstacles with renewable electric energy conversion systems are often referred to the intermittency of the energy sources and the relatively high maintenance cost. However, due to an intensified discourse on climate change and its effects, it has from a societal point of view, become more desirable to adopt and install CO 2 neutral power plants. Even if this has increased the competitiveness of RETs in a political sense, the new goals for RET installations must also be met with economical viability. We propose that the direction of technical development, as well as the chosen technology in new installations, should not primarily be determined by policies, but by the basic physical properties of the energy source and the associated potential for inexpensive energy production. This potential is the basic entity that drives the payback of the investment of a specific RET power plant. With regard to this, we argue that the total electric energy conversion system must be considered if effective power production is to be achieved, with focus on the possible number of full loading hours and the Degree of Utilization. This will increase the cost efficiency and economical competitiveness of RET investments, and could enhance faster diffusion of new innovations and installations without over-optimistic subsidies. This paper elaborates on the overall problem of the economy of renewable electric energy conversion systems by studying the interface between physics, engineering and economy reported for RET power plants in different scientific publications. The core objective is to show the practical use of the Degree of Utilization and how the concept is crucial for the design and economical optimization disregarding subsidies. The results clearly indicate that the future political regulative frameworks should consider the choice of renewable energy

  5. Near-infrared Polarimetry of the Outflow Source AFGL 6366S: Detection of Circular Polarization

    Kwon, Jungmi; Nakagawa, Takao; Tamura, Motohide; Hough, James H.; Kandori, Ryo; Choi, Minho; Kang, Miju; Cho, Jungyeon; Nakajima, Yasushi; Nagata, Tetsuya

    2018-07-01

    We have carried out near-infrared circular and linear imaging polarimetry of the AFGL 6366S region. There is one large infrared reflection nebula associated with the AFGL 6366S cluster and one small infrared reflection nebula associated with AFGL 6366S NE. Prominent and extended polarized nebulosities over the AFGL 6366S cluster field are found to be composed of several components and local nebula peaks, and those nebulosities are illuminated by at least three sources, which is roughly consistent with a previous study. However, the detailed linear polarization patterns and their degrees differ from the earlier study. The brightest regions of the nebulae are illuminated by the IRAS/WISE source. In addition, we report the first detection of circular polarization (CP) in the reflection nebula associated with AFGL 6366S. The CP is as large as approximately 4% in the K s band, and the maximum CP extent is approximately 0.45 pc, which is comparable to that for the largest CP regions known to date, such as Orion and Mon R2, although the CP degrees are much smaller. The CP pattern is mostly quadrupolar, and its morphology resembles the shape of the C18O dense core. Therefore, the CP region is probably illuminated by the IRAS/WISE source and its polarization is amplified by the dichroic absorption of the dense core associated with the cluster. This is the ninth source whose degrees of CPs are measured to be greater than 3%, suggesting that large and extended infrared CP regions are common among mid- to high-mass young stellar objects.

  6. Multifunctional Pt(II) Reagents: Covalent Modifications of Pt Complexes Enable Diverse Structural Variation and In-Cell Detection.

    White, Jonathan D; Haley, Michael M; DeRose, Victoria J

    2016-01-19

    To enhance the functionality of Pt-based reagents, several strategies have been developed that utilize Pt compounds modified with small, reactive handles. This Account encapsulates work done by us and other groups regarding the use of Pt(II) compounds with reactive handles for subsequent elaboration with fluorophores or other functional moieties. Described strategies include the incorporation of substituents for well-known condensation or nucleophilic displacement-type reactions and their use, for example, to tether spectroscopic handles to Pt reagents for in vivo investigation. Other chief uses of displacement-type reactions have included tethering various small molecules exhibiting pharmacological activity directly to Pt, thus adding synergistic effects. Click chemistry-based ligation techniques have also been applied, primarily with azide- and alkyne-appended Pt complexes. Orthogonally reactive click chemistry reactions have proven invaluable when more traditional nucleophilic displacement reactions induce side-reactivity with the Pt center or when systematic functionalization of a larger number of Pt complexes is desired. Additionally, a diverse assortment of Pt-fluorophore conjugates have been tethered via click chemistry conjugation. In addition to providing a convenient synthetic path for diversifying Pt compounds, the use of click-capable Pt complexes has proved a powerful strategy for postbinding covalent modification and detection with fluorescent probes. This strategy bypasses undesirable influences of the fluorophore camouflaged as reactivity due to Pt that may be present when detecting preattached Pt-fluorophore conjugates. Using postbinding strategies, Pt reagent distributions in HeLa and lung carcinoma (NCI-H460) cell cultures were observed with two different azide-modified Pt compounds, a monofunctional Pt(II)-acridine type and a difunctional Pt(II)-neutral complex. In addition, cellular distribution was observed with an alkyne-appended difunctional

  7. Technology and applications of broad-beam ion sources used in sputtering. Part II. Applications

    Harper, J.M.E.; Cuomo, J.J.; Kaufman, H.R.

    1982-01-01

    The developments in broad-beam ion source technology described in the companion paper (Part I) have stimulated a rapid expansion in applications to materials processing. These applications are reviewed here, beginning with a summary of sputtering mechanisms. Next, etching applications are described, including microfabrication and reactive ion beam etching. The developing area of surface layer applications is summarized, and related to the existing fields of oxidation and implantation. Next, deposition applications are reviewed, including ion-beam sputter deposition and the emerging technique of ion-assisted vapor deposition. Many of these applications have been stimulated by the development of high current ion sources operating in the energy range of tens of hundreds of eV. It is in this energy range that ion-activated chemical etching is efficient, self-limiting compound layers can be grown, and the physical properties of vapor-deposited films can be modified. In each of these areas, broad ion beam technology provides a link between other large area plasma processes and surface analytical techniques using ion beams

  8. In-source collision induced dissociation of inorganic explosives for mass spectrometric signature detection and chemical imaging

    Forbes, Thomas P., E-mail: thomas.forbes@nist.gov; Sisco, Edward

    2015-09-10

    The trace detection, bulk quantification, and chemical imaging of inorganic explosives and components was demonstrated utilizing in-source collision induced dissociation (CID) coupled with laser desorption/ionization mass spectrometry (LDI-MS). The incorporation of in-source CID provided direct control over the extent of adduct and cluster fragmentation as well as organic noise reduction for the enhanced detection of both the elemental and molecular ion signatures of fuel-oxidizer mixtures and other inorganic components of explosive devices. Investigation of oxidizer molecular anions, specifically, nitrates, chlorates, and perchlorates, identified that the optimal in-source CID existed at the transition between fragmentation of the ionic salt bonds and molecular anion bonds. The chemical imaging of oxidizer particles from latent fingerprints was demonstrated, including both cation and anion components in positive and negative mode mass spectrometry, respectively. This investigation demonstrated LDI-MS with in-source CID as a versatile tool for security fields, as well as environmental monitoring and nuclear safeguards, facilitating the detection of elemental and molecular inorganic compounds at nanogram levels. - Highlights: • In-source CID enhanced detection of elemental inorganics up to 1000-fold. • In-source CID optimization of polyatomic oxidizers enhanced detection up to 100-fold. • Optimal CID identified at transition from breaking ionic salt to molecular anion bonds. • Trace detection of inorganic explosives at nanogram levels was demonstrated. • Oxidizer particles were chemically imaged directly from latent fingerprints.

  9. Anoxic and Oxic Oxidation of Rocks Containing Fe(II)Mg-Silicates and Fe(II)-Monosulfides as Source of Fe(III)-Minerals and Hydrogen. Geobiotropy.

    Bassez, Marie-Paule

    2017-12-01

    In this article, anoxic and oxic hydrolyses of rocks containing Fe (II) Mg-silicates and Fe (II)-monosulfides are analyzed at 25 °C and 250-350 °C. A table of the products is drawn. It is shown that magnetite and hydrogen can be produced during low-temperature (25 °C) anoxic hydrolysis/oxidation of ferrous silicates and during high-temperature (250 °C) anoxic hydrolysis/oxidation of ferrous monosulfides. The high-T (350 °C) anoxic hydrolysis of ferrous silicates leads mainly to ferric oxides/hydroxides such as the hydroxide ferric trihydroxide, the oxide hydroxide goethite/lepidocrocite and the oxide hematite, and to Fe(III)-phyllosilicates. Magnetite is not a primary product. While the low-T (25 °C) anoxic hydrolysis of ferrous monosulfides leads to pyrite. Thermodynamic functions are calculated for elementary reactions of hydrolysis and carbonation of olivine and pyroxene and E-pH diagrams are analyzed. It is shown that the hydrolysis of the iron endmember is endothermic and can proceed within the exothermic hydrolysis of the magnesium endmember and also within the exothermic reactions of carbonations. The distinction between three products of the iron hydrolysis, magnetite, goethite and hematite is determined with E-pH diagrams. The hydrolysis/oxidation of the sulfides mackinawite/troilite/pyrrhotite is highly endothermic but can proceed within the heat produced by the exothermic hydrolyses and carbonations of ferromagnesian silicates and also by other sources such as magma, hydrothermal sources, impacts. These theoretical results are confirmed by the products observed in several related laboratory experiments. The case of radiolyzed water is studied. It is shown that magnetite and ferric oxides/hydroxides such as ferric trihydroxide, goethite/lepidocrocite and hematite are formed in oxic hydrolysis of ferromagnesian silicates at 25 °C and 350 °C. Oxic oxidation of ferrous monosulfides at 25 °C leads mainly to pyrite and ferric oxides/hydroxides such as

  10. Sources

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  11. Joint Biological Standoff Detection System increment II: Field Demonstration - SINBAHD Performances

    Buteau, Sylvie; Simard, Jean-Robert; Lahaie, Pierre; Roy, Gilles; Mathieu, Pierre; McFee, John; Ho, Jim

    2007-01-01

    ... (Stand-off INtegrated Bioaerosol Active Hyperspectral Detection) aimed at evaluating the capability of using UV LIF with intensified range-gated spectrometry to detect and characterize bioaerosol from stand-off position...

  12. Testing seismic amplitude source location for fast debris-flow detection at Illgraben, Switzerland

    Walter, Fabian; Burtin, Arnaud; McArdell, Brian W.; Hovius, Niels; Weder, Bianca; Turowski, Jens M.

    2017-06-01

    Heavy precipitation can mobilize tens to hundreds of thousands of cubic meters of sediment in steep Alpine torrents in a short time. The resulting debris flows (mixtures of water, sediment and boulders) move downstream with velocities of several meters per second and have a high destruction potential. Warning protocols for affected communities rely on raising awareness about the debris-flow threat, precipitation monitoring and rapid detection methods. The latter, in particular, is a challenge because debris-flow-prone torrents have their catchments in steep and inaccessible terrain, where instrumentation is difficult to install and maintain. Here we test amplitude source location (ASL) as a processing scheme for seismic network data for early warning purposes. We use debris-flow and noise seismograms from the Illgraben catchment, Switzerland, a torrent system which produces several debris-flow events per year. Automatic in situ detection is currently based on geophones mounted on concrete check dams and radar stage sensors suspended above the channel. The ASL approach has the advantage that it uses seismometers, which can be installed at more accessible locations where a stable connection to mobile phone networks is available for data communication. Our ASL processing uses time-averaged ground vibration amplitudes to estimate the location of the debris-flow front. Applied to continuous data streams, inversion of the seismic amplitude decay throughout the network is robust and efficient, requires no manual identification of seismic phase arrivals and eliminates the need for a local seismic velocity model. We apply the ASL technique to a small debris-flow event on 19 July 2011, which was captured with a temporary seismic monitoring network. The processing rapidly detects the debris-flow event half an hour before arrival at the outlet of the torrent and several minutes before detection by the in situ alarm system. An analysis of continuous seismic records furthermore

  13. Testing seismic amplitude source location for fast debris-flow detection at Illgraben, Switzerland

    F. Walter

    2017-06-01

    Full Text Available Heavy precipitation can mobilize tens to hundreds of thousands of cubic meters of sediment in steep Alpine torrents in a short time. The resulting debris flows (mixtures of water, sediment and boulders move downstream with velocities of several meters per second and have a high destruction potential. Warning protocols for affected communities rely on raising awareness about the debris-flow threat, precipitation monitoring and rapid detection methods. The latter, in particular, is a challenge because debris-flow-prone torrents have their catchments in steep and inaccessible terrain, where instrumentation is difficult to install and maintain. Here we test amplitude source location (ASL as a processing scheme for seismic network data for early warning purposes. We use debris-flow and noise seismograms from the Illgraben catchment, Switzerland, a torrent system which produces several debris-flow events per year. Automatic in situ detection is currently based on geophones mounted on concrete check dams and radar stage sensors suspended above the channel. The ASL approach has the advantage that it uses seismometers, which can be installed at more accessible locations where a stable connection to mobile phone networks is available for data communication. Our ASL processing uses time-averaged ground vibration amplitudes to estimate the location of the debris-flow front. Applied to continuous data streams, inversion of the seismic amplitude decay throughout the network is robust and efficient, requires no manual identification of seismic phase arrivals and eliminates the need for a local seismic velocity model. We apply the ASL technique to a small debris-flow event on 19 July 2011, which was captured with a temporary seismic monitoring network. The processing rapidly detects the debris-flow event half an hour before arrival at the outlet of the torrent and several minutes before detection by the in situ alarm system. An analysis of continuous seismic

  14. Monte Carlo modeling and analyses of YALINA- booster subcritical assembly Part II: pulsed neutron source

    Talamo, A.; Gohar, M.Y.A.; Rabiti, C.

    2008-01-01

    One of the most reliable experimental methods for measuring the kinetic parameters of a subcritical assembly is the Sjoestrand method applied to the reaction rate generated from a pulsed neutron source. This study developed a new analytical methodology for characterizing the kinetic parameters of a subcritical assembly using the Sjoestrand method, which allows comparing the analytical and experimental time dependent reaction rates and the reactivity measurements. In this methodology, the reaction rate, detector response, is calculated due to a single neutron pulse using MCNP/MCNPX computer code or any other neutron transport code that explicitly simulates the fission delayed neutrons. The calculation simulates a single neutron pulse over a long time period until the delayed neutron contribution to the reaction is vanished. The obtained reaction rate is superimposed to itself, with respect to the time, to simulate the repeated pulse operation until the asymptotic level of the reaction rate, set by the delayed neutrons, is achieved. The superimposition of the pulse to itself was calculated by a simple C computer program. A parallel version of the C program is used due to the large amount of data being processed, e.g. by the Message Passing Interface (MPI). The new calculation methodology has shown an excellent agreement with the experimental results available from the YALINA-Booster facility of Belarus. The facility has been driven by a Deuterium-Deuterium or Deuterium-Tritium pulsed neutron source and the (n,p) reaction rate has been experimentally measured by a 3 He detector. The MCNP calculation has utilized the weight window and delayed neutron biasing variance reduction techniques since the detector volume is small compared to the assembly volume. Finally, this methodology was used to calculate the IAEA benchmark of the YALINA-Booster experiment

  15. CHANDRA ACIS SURVEY OF X-RAY POINT SOURCES IN NEARBY GALAXIES. II. X-RAY LUMINOSITY FUNCTIONS AND ULTRALUMINOUS X-RAY SOURCES

    Wang, Song; Qiu, Yanli; Liu, Jifeng [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Bregman, Joel N., E-mail: songw@bao.ac.cn, E-mail: jfliu@bao.ac.cn [University of Michigan, Ann Arbor, MI 48109 (United States)

    2016-09-20

    Based on the recently completed Chandra /ACIS survey of X-ray point sources in nearby galaxies, we study the X-ray luminosity functions (XLFs) for X-ray point sources in different types of galaxies and the statistical properties of ultraluminous X-ray sources (ULXs). Uniform procedures are developed to compute the detection threshold, to estimate the foreground/background contamination, and to calculate the XLFs for individual galaxies and groups of galaxies, resulting in an XLF library of 343 galaxies of different types. With the large number of surveyed galaxies, we have studied the XLFs and ULX properties across different host galaxy types, and confirm with good statistics that the XLF slope flattens from lenticular ( α ∼ 1.50 ± 0.07) to elliptical (∼1.21 ± 0.02), to spirals (∼0.80 ± 0.02), to peculiars (∼0.55 ± 0.30), and to irregulars (∼0.26 ± 0.10). The XLF break dividing the neutron star and black hole binaries is also confirmed, albeit at quite different break luminosities for different types of galaxies. A radial dependency is found for ellipticals, with a flatter XLF slope for sources located between D {sub 25} and 2 D {sub 25}, suggesting the XLF slopes in the outer region of early-type galaxies are dominated by low-mass X-ray binaries in globular clusters. This study shows that the ULX rate in early-type galaxies is 0.24 ± 0.05 ULXs per surveyed galaxy, on a 5 σ confidence level. The XLF for ULXs in late-type galaxies extends smoothly until it drops abruptly around 4 × 10{sup 40} erg s{sup −1}, and this break may suggest a mild boundary between the stellar black hole population possibly including 30 M {sub ⊙} black holes with super-Eddington radiation and intermediate mass black holes.

  16. Electron Signal Detection for the Beam-Finder Wire of the Linac Coherent Light Source Undulator

    Wu, Juhao; Emma, P.; Field, R.C.; SLAC

    2006-01-01

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. The tight tolerances for positioning the electron beam close to the undulator axis calls for the introduction of Beam Finder Wire (BFW) device. A BFW device close to the upstream end of the undulator segment and a quadrupole close to the down stream end of the undulator segment will allow a beam-based undulator segment alignment. Based on the scattering of the electrons on the BFW, we can detect the electron signal in the main dump bends after the undulator to find the beam position. We propose to use a threshold Cherenkov counter for this purpose. According to the signal strength at such a Cherenkov counter, we then suggest choice of material and size for such a BFW device in the undulator

  17. Advanced Laser-Compton Gamma-Ray Sources for Nuclear Materials Detection, Assay and Imaging

    Barty, C. P. J.

    2015-10-01

    Highly-collimated, polarized, mono-energetic beams of tunable gamma-rays may be created via the optimized Compton scattering of pulsed lasers off of ultra-bright, relativistic electron beams. Above 2 MeV, the peak brilliance of such sources can exceed that of the world's largest synchrotrons by more than 15 orders of magnitude and can enable for the first time the efficient pursuit of nuclear science and applications with photon beams, i.e. Nuclear Photonics. Potential applications are numerous and include isotope-specific nuclear materials management, element-specific medical radiography and radiology, non-destructive, isotope-specific, material assay and imaging, precision spectroscopy of nuclear resonances and photon-induced fission. This review covers activities at the Lawrence Livermore National Laboratory related to the design and optimization of mono-energetic, laser-Compton gamma-ray systems and introduces isotope-specific nuclear materials detection and assay applications enabled by them.

  18. Loss distribution approach for operational risk capital modelling under Basel II: Combining different data sources for risk estimation

    Pavel V. Shevchenko

    2013-07-01

    Full Text Available The management of operational risk in the banking industry has undergone significant changes over the last decade due to substantial changes in operational risk environment. Globalization, deregulation, the use of complex financial products and changes in information technology have resulted in exposure to new risks very different from market and credit risks. In response, Basel Committee for banking Supervision has developed a regulatory framework, referred to as Basel II, that introduced operational risk category and corresponding capital requirements. Over the past five years, major banks in most parts of the world have received accreditation under the Basel II Advanced Measurement Approach (AMA by adopting the loss distribution approach (LDA despite there being a number of unresolved methodological challenges in its implementation. Different approaches and methods are still under hot debate. In this paper, we review methods proposed in the literature for combining different data sources (internal data, external data and scenario analysis which is one of the regulatory requirement for AMA.

  19. Status report on the cold neutron source of the Garching neutron research facility FRM-II

    Gobrecht, K.; Gutsmiedl, E.; Scheuer, A.

    2001-01-01

    The new high flux research reactor of the Technical University of Munich (Technische Universitaet Muenchen, TUM) will be equipped with a cold neutron source (CNS). The centre of the CNS will be located in the D2O-reflector tank at 400 mm from the reactor core axis, close to the thermal neutron flux maximum. The power of 4500 W developed by the nuclear heating in the 16 litres of liquid deuterium at 25 K, and in the structures, is evacuated by a two phase thermal siphon avoiding film boiling and flooding. The thermal siphon is a single tube with counter current flow. It is inclined by 10deg from vertical, and optimised for a deuterium flow rate of 14 g/s. Optimisation of structure design and material, as well as safety aspects will be discussed. Those parts of the structure, which are exposed to high thermal neutron flux, are made from Zircaloy 4 and 6061T6 aluminium. Structure failure due to embrittlement of the structure material under high rapid neutron flux is very importable during the life time of the CNS (30 years). Double, in pile even triple, containment with inert gas liner guarantees lack of explosion risk and of tritium contamination to the environment. Adding a few percent of hydrogen (H2) to the deuterium (D2) will improve the moderating properties of our relatively small moderator volume. Nearly all of the hydrogen is bound in the form of HD molecules. The new reactor will have 13 beam tubes, 4 of which are looking at the cold neutron source (CNS), including two for very cold (VCN) and ultra-cold neutron (UCN) production. The latter will take place in the horizontal beam tube SR4, which will house an additional cryogenic moderator (e.g. solid deuterium). More than 60% of the experiments foreseen in the new neutron research facility will use cold neutrons from the CNS. The mounting of the hardware components of the CNS into the reactor has started in the spring of 2000. The CNS will go into trial operation in the end of year 2000. (J.P.N.)

  20. Status report on the cold neutron source of the Garching neutron research facility FRM-II

    Gobrecht, K.

    1999-01-01

    The new high flux research reactor of the Technical University of Munich (Technische Universitaet Muenchen, TUM) will be equipped with a cold neutron source (CNS). The centre of the CNS will be located in the D 2 O-reflector tank at 400 mm from the reactor core axis, close to the thermal neutron flux maximum. The power of 4000 W developed by the nuclear heating in the 16 litres of liquid deuterium at 25 K, and in the structures, is evacuated by a two phase thermal siphon avoiding film boiling and flooding. The thermal siphon is a single tube with counter current flow. It is inclined by 10 deg from vertical, and optimised for a deuterium flow rate of 14 g/s. Optimisation of structure design and material, as well as safety aspects will be discussed. Those parts of the structure, which are exposed to high thermal neutron flux, are made from Zircaloy 4 and 6061T6 aluminium. Structure failure due to embrittlement of the structure material under high rapid neutron flux is very improbable during the life time of the CNS (30 years). Double, in pile even triple, containment with inert gas liner guarantees lack of explosion risk and of tritium contamination to the environment. Adding a few percent of hydrogen (H 2 ) to the deuterium (D 2 ) will improve the moderating properties of our relatively small moderator volume. Nearly all of the hydrogen is bound in the form of HD molecules. A long term change of the hydrogen content in the deuterium is avoided be storing the mixture not in a gas buffer volume but as a metal hydride at low pressure. The metal hydride storage system contains two getter beds, one with 250 kg of LaCo 3 Ni 2 , the other one with 150 kg of ZrCo(0.8)Ni(0.2). Each bed can take the total gas inventory, both beds together can absorb the total gas inventory in less than 6 minutes at a pressure < 3 bar. The new reactor will have 13 beam tubes, 4 of which are looking at the cold neutron source (CNS), including two for very cold (VCN) and ultra-cold neutron (UCN

  1. The optimal on-source region size for detections with counting-type telescopes

    Klepser, Stefan

    2017-01-15

    The on-source region is typically a circular area with radius θ in which the signal is expected to appear with the shape of the instrument point spread function (PSF). This paper addresses the question of what is the θ that maximises the probability of detection for a given PSF width and background event density. In the high count number limit and assuming a Gaussian PSF profile, the optimum is found to be at ζ{sup 2}{sub ∞}∼2.51 times the squared PSF width σ{sup 2}{sub PSF39}. While this number is shown to be a good choice in many cases, a dynamic formula for cases of lower count numbers, which favour larger on-source regions, is given. The recipe to get to this parametrisation can also be applied to cases with a non-Gaussian PSF. This result can standardise and simplify analysis procedures, reduce trials and eliminate the need for experience-based ad hoc cut definitions or expensive case-by-case Monte Carlo simulations.

  2. Application of wireless sensor network to problems of detection and tracking of radioactive sources

    Dupuy, P

    2006-01-01

    International efforts are being conducted to warranty a continuous control of radioactive sources. A theoretical and practical study has been achieved about the feasibility of installing wireless sensor networks on nuclear installations, or plants that uses radioactive material. The study is faced through the implementation of a system designed over the relatively new platform of motes, that gives a great flexibility for distributing sensors taking advantages of new wireless technologies and high-level programming. The work shows an analysis of the state of the technique of sensors, detectors, antennas and power supply including nuclear power supply. It also shows contributions on these fields by experimentation and proposed designs. Three applications that justify the technology are shown and a demonstration project is proposed. The social improvements of the system basically are a technical approach to the continuous control of radioactive sources during their life cycle and the online monitoring of the staff with the possibility of identifying and optimizing the procedures that are the maximum of expositions in practice or detecting potentials expositions [es

  3. The optimal on-source region size for detections with counting-type telescopes

    Klepser, Stefan

    2017-01-01

    The on-source region is typically a circular area with radius θ in which the signal is expected to appear with the shape of the instrument point spread function (PSF). This paper addresses the question of what is the θ that maximises the probability of detection for a given PSF width and background event density. In the high count number limit and assuming a Gaussian PSF profile, the optimum is found to be at ζ"2_∞∼2.51 times the squared PSF width σ"2_P_S_F_3_9. While this number is shown to be a good choice in many cases, a dynamic formula for cases of lower count numbers, which favour larger on-source regions, is given. The recipe to get to this parametrisation can also be applied to cases with a non-Gaussian PSF. This result can standardise and simplify analysis procedures, reduce trials and eliminate the need for experience-based ad hoc cut definitions or expensive case-by-case Monte Carlo simulations.

  4. A program for the a priori evaluation of detection limits in instrumental neutron activation analysis using a SLOWPOKE II reactor

    Galinier, J.L.; Zikovsky, L.

    1982-01-01

    A program that permits the a priori calculation of detection limits in monoelemental matrices, adapted to instrumental neutron activation analysis using a SLOWPOKE II reactor, is described. A simplified model of the gamma spectra is proposed. Products of (n,p) and (n,α) reactions induced by the fast components of the neutron flux that accompanies the thermal flux at the level of internal irradiation sites in the reactor have been included in the list of interfering radionuclides. The program calculates in a systematic way the detection limits of 66 elements in an equal number of matrices using 153 intermediary radionuclides. Experimental checks carried out with silicon (for short lifetimes) and aluminum and magnesium (for intermediate lifetimes) show satisfactory agreement with the calculations. These results show in particular the importance of the contribution of the (n,p) and (n,α) reactions in the a priori evaluation of detection limits with a SLOWPOKE type reactor [fr

  5. Detecting stellar-wind bubbles through infrared arcs in H II regions

    Mackey, Jonathan; Haworth, Thomas J.; Gvaramadze, Vasilii V.; Mohamed, Shazrene; Langer, Norbert; Harries, Tim J.

    2016-02-01

    Mid-infrared arcs of dust emission are often seen near ionizing stars within H II regions. A possible explanations for these arcs is that they could show the outer edges of asymmetric stellar wind bubbles. We use two-dimensional, radiation-hydrodynamics simulations of wind bubbles within H II regions around individual stars to predict the infrared emission properties of the dust within the H II region. We assume that dust and gas are dynamically well-coupled and that dust properties (composition, size distribution) are the same in the H II region as outside it, and that the wind bubble contains no dust. We post-process the simulations to make synthetic intensity maps at infrared wavebands using the torus code. We find that the outer edge of a wind bubble emits brightly at 24 μm through starlight absorbed by dust grains and re-radiated thermally in the infrared. This produces a bright arc of emission for slowly moving stars that have asymmetric wind bubbles, even for cases where there is no bow shock or any corresponding feature in tracers of gas emission. The 24 μm intensity decreases exponentially from the arc with increasing distance from the star because the dust temperature decreases with distance. The size distribution and composition of the dust grains has quantitative but not qualitative effects on our results. Despite the simplifications of our model, we find good qualitative agreement with observations of the H II region RCW 120, and can provide physical explanations for any quantitative differences. Our model produces an infrared arc with the same shape and size as the arc around CD -38°11636 in RCW 120, and with comparable brightness. This suggests that infrared arcs around O stars in H II regions may be revealing the extent of stellar wind bubbles, although we have not excluded other explanations.

  6. Exploring the Variability of the Flat-spectrum Radio Source 1633+382. II. Physical Properties

    Algaba, Juan-Carlos; Lee, Sang-Sung; Rani, Bindu; Kim, Dae-Won; Kino, Motoki; Hodgson, Jeffrey; Zhao, Guang-Yao; Byun, Do-Young; Gurwell, Mark; Kang, Sin-Cheol; Kim, Jae-Young; Kim, Jeong-Sook; Kim, Soon-Wook; Park, Jong-Ho; Trippe, Sascha; Wajima, Kiyoaki

    2018-06-01

    The flat-spectrum radio quasar 1633+382 (4C 38.41) showed a significant increase of its radio flux density during the period 2012 March–2015 August, which correlates with γ-ray flaring activity. Multi-frequency simultaneous very long baseline interferometry (VLBI) observations were conducted as part of the interferometric monitoring of gamma-ray bright active galactic nuclei (iMOGABA) program and supplemented with additional radio monitoring observations with the OVRO 40 m telescope, the Boston University VLBI program, and the Submillimeter Array. The epochs of the maxima for the two largest γ-ray flares coincide with the ejection of two respective new VLBI components. Analysis of the spectral energy distribution indicates a higher turnover frequency after the flaring events. The evolution of the flare in the turnover frequency-turnover flux density plane probes the adiabatic losses in agreement with the shock-in-jet model. The derived synchrotron self-absorption magnetic fields, of the order of 0.1 mG, do not seem to change dramatically during the flares, and are much weaker, by a factor 104, than the estimated equipartition magnetic fields, indicating that the source of the flare may be associated with a particle-dominated emitting region.

  7. THE EARLY DETECTION OF THE EMERALD ASH BORER (EAB USING MULTI-SOURCE REMOTELY SENSED DATA

    B. Hu

    2018-04-01

    Full Text Available The objectives of this study were to exploit the synergy of hyperspectral imagery, Light Detection And Ranging (LiDAR and high spatial resolution data and their synergy in the early detection of the EAB (Emerald Ash Borer presence in trees within urban areas and to develop a framework to combine information extracted from multiple data sources. To achieve these, an object-oriented framework was developed to combine information derived from available data sets to characterize ash trees. Within this framework, an advanced individual tree delineation method was developed to delineate individual trees using the combined high-spatial resolution worldview-3 imagery was used together with LiDAR data. Individual trees were then classified to ash and non-ash trees using spectral and spatial information. In order to characterize the health state of individual ash trees, leaves from ash trees with various health states were sampled and measured using a field spectrometer. Based on the field measurements, the best indices that sensitive to leaf chlorophyll content were selected. The developed framework and methods were tested using worldview-3, airborne LiDAR data over the Keele campus of York University Toronto Canada. Satisfactory results in terms of individual tree crown delineation, ash tree identification and characterization of the health state of individual ash trees. Quantitative evaluations is being carried out.

  8. The Early Detection of the Emerald Ash Borer (eab) Using Multi-Source Remotely Sensed Data

    Hu, B.; Naveed, F.; Tasneem, F.; Xing, C.

    2018-04-01

    The objectives of this study were to exploit the synergy of hyperspectral imagery, Light Detection And Ranging (LiDAR) and high spatial resolution data and their synergy in the early detection of the EAB (Emerald Ash Borer) presence in trees within urban areas and to develop a framework to combine information extracted from multiple data sources. To achieve these, an object-oriented framework was developed to combine information derived from available data sets to characterize ash trees. Within this framework, an advanced individual tree delineation method was developed to delineate individual trees using the combined high-spatial resolution worldview-3 imagery was used together with LiDAR data. Individual trees were then classified to ash and non-ash trees using spectral and spatial information. In order to characterize the health state of individual ash trees, leaves from ash trees with various health states were sampled and measured using a field spectrometer. Based on the field measurements, the best indices that sensitive to leaf chlorophyll content were selected. The developed framework and methods were tested using worldview-3, airborne LiDAR data over the Keele campus of York University Toronto Canada. Satisfactory results in terms of individual tree crown delineation, ash tree identification and characterization of the health state of individual ash trees. Quantitative evaluations is being carried out.

  9. Using Stable Isotopes to Detect Land Use Change and Nitrogen Sources in Aquatic Systems

    Rogers, K. M. [National Isotope Center, GNS Science, Lower Hutt (New Zealand)

    2013-05-15

    Changing land use is one of the primary causes of increased sedimentation and nutrient levels in aquatic systems, resulting in contamination and reduction of biodiversity. Detecting and quantifying these inputs is the first step towards remediation, and enabling targeted reductions of transport processes into waterways from human impacted land surfaces. More recently, stable isotope analyses are being used as detection and quantification tools in aquatic environments. Carbon ({delta}{sup 13}C) and nitrogen ({delta}{sup 15}N) isotopes of sediments, as well as algae and invertebrates from aquatic systems can be used as proxies to record both short and long term environmental change. Excess nitrogen (or nitrogen-compounds) derived from urbanization, industry, forestry, farming and agriculture, increase the bioavailability of nitrogen to aquatic organisms, changing their natural {delta}15N isotopic signatures. Allochthonous (terrestrial) input from soil destabilization and human activity in surrounding catchments changes {delta}{sup 13}C isotopic compositions and increases the C:N ratio of sediments. Heavy metal and other organic pollutants can also be used to indicate urbanization and industrial contamination. The combined use of carbon and nitrogen isotopes, C:N ratios and heavy metals are powerful environmental monitoring tools, which are useful indicators of source and transport pathways of terrestrial derived material and anthropogenic pollutants into streams, rivers and estuaries. (author)

  10. Application of random-point processes to the detection of radiation sources

    Woods, J.W.

    1978-01-01

    In this report the mathematical theory of random-point processes is reviewed and it is shown how use of the theory can obtain optimal solutions to the problem of detecting radiation sources. As noted, the theory also applies to image processing in low-light-level or low-count-rate situations. Paralleling Snyder's work, the theory is extended to the multichannel case of a continuous, two-dimensional (2-D), energy-time space. This extension essentially involves showing that the data are doubly stochastic Poisson (DSP) point processes in energy as well as time. Further, a new 2-D recursive formulation is presented for the radiation-detection problem with large computational savings over nonrecursive techniques when the number of channels is large (greater than or equal to 30). Finally, some adaptive strategies for on-line ''learning'' of unknown, time-varying signal and background-intensity parameters and statistics are present and discussed. These adaptive procedures apply when a complete statistical description is not available a priori

  11. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources

    Klumpp, John [Colorado State University, Department of Environmental and Radiological Health Sciences, Molecular and Radiological Biosciences Building, Colorado State University, Fort Collins, Colorado, 80523 (United States)

    2013-07-01

    We propose a radiation detection system which generates its own discrete sampling distribution based on past measurements of background. The advantage to this approach is that it can take into account variations in background with respect to time, location, energy spectra, detector-specific characteristics (i.e. different efficiencies at different count rates and energies), etc. This would therefore be a 'machine learning' approach, in which the algorithm updates and improves its characterization of background over time. The system would have a 'learning mode,' in which it measures and analyzes background count rates, and a 'detection mode,' in which it compares measurements from an unknown source against its unique background distribution. By characterizing and accounting for variations in the background, general purpose radiation detectors can be improved with little or no increase in cost. The statistical and computational techniques to perform this kind of analysis have already been developed. The necessary signal analysis can be accomplished using existing Bayesian algorithms which account for multiple channels, multiple detectors, and multiple time intervals. Furthermore, Bayesian machine-learning techniques have already been developed which, with trivial modifications, can generate appropriate decision thresholds based on the comparison of new measurements against a nonparametric sampling distribution. (authors)

  12. Development of a Novel Fiber Optic Sensor Combined with a Fluorescence Turn-on Probe for Cu (II Detection

    Ma J.

    2013-04-01

    Full Text Available Existing staining-based methodology for the detection of metal ions is not well suited for real-time or in situ use. This is a significant problem, given that these ions can have a considerable impact on both human health and the environment. Thus, there is growing interest and need for simple, rapid and in-situ monitoring techniques for the purpose of detecting various target analytes (e.g. heavy metals, which is of a significant importance in many fields ranging from environmental monitoring to the study of intracellular processes. Among various sensors developed, optical fiber-optic sensors (FOS, based on fluorescence, are one class of sensors that address this goal [1]. Optical fibers are ideal for environmental sensing applications because of their ability to transmit optical signals to and from the sensing region without the use of free-space optics. In this work, we present, for the first time, a simple FOS incorporating novel fluorescence turn-on mechanism [2] that could detect Cu (II as low as 10−4 M. Traditionally, fluorescence quenching or “turn-off” was used to detect Cu (II [3]. In recent years, fluorescence “turn-on” emerges as a preferable tool. The developed fiber-optic sensor has two fiber leads and one probe head. One fiber lead includes 6 fibers for He-Ne laser excitation light delivery (e-fibers. Another fiber lead has one receiving fiber (r-fiber connected to an Ocean Optics QE65000 scientific grade spectrometer, which is interrogated by a computer via USB connection. The SpectroSuite software is used to observe and to record all spectra. The probe head combines all fibers together to form a coaxial structure with the r-fiber placed in the center. The key component in the proposed fluorescent sensing system is a probe prepared by binding a receptor containing a zwitterionic chromophore (M1, through noncovalent interactions, to the fluorescent polymer (P1 resulting in quenching its emission. The sensing mechanism

  13. A fluorescence detected magnetic resonance investigation of the carotenoid triplet states associated with Photosystem II of isolated spinach thylakoid membranes

    Santabarbara, S; Carbonera, D; Heathcote, P

    2005-01-01

    The carotenoid triplet populations associated with the fluorescence emission chlorophyll forms of Photosystem II have been investigated in isolated spinach thylakoid membranes by means of fluorescence detected magnetic resonance in zero field (FDMR). The spectra collected in the 680-690 nm emission range, have been fitted by a global analysis procedure. At least five different carotenoid triplet states coupled to the terminal emitting chlorophyll forms of PS II, peaking at 682 nm, 687 nm and 692 nm, have been characterised. The triplets associated with the outer antenna emission forms, at 682 nm, have zero field splitting parameters D = 0.0385 cm/sup -1/, E = 0.00367 cm/sup -1/; D = 0.0404 cm/sup -1/, E = 0.00379 cm/sup -1/ and D = 0.0386 cm/sup -1/, E = 0.00406 cm/sup -1/ which are very similar to those previously reported for the xanthophylls of the isolated LHC II complex. Therefore the FDMR spectra recorded in this work provide insights into the organisation of the LHC II complex in the unperturbed enviro...

  14. Elevated source SF6-tracer dispersion experiments in the Copenhagen area. Preliminary results II

    Gryning, S.E.; Lyck, E.

    1980-01-01

    The results from 10 experiments, performed in neutral to unstable meteorological conditions, are reported from an ongoing series of elevated-source, urban-scale tracer dispersion experiments in the Copenhagen area. The tracer is released at a height of 115 m from the TV-tower in GLADSAXE, a suburb of Copenhagen, with tracer sampling units positioned at ground-level in 1 to 3 crosswind series, 2 to 6 km downwind of the tower. The lateral dispersion parameter, sigma(y), was estimated from the measured tracer concentration distribution and compared with values of sigma(y), computed by 1) methods based on wind variance measured during the experiments and 2) methods based on a stability classification of the atmospheric conditions. The wind-variance based methods proved superior in predicting the variation of sigma(y) compared with the stability based methods. Moreover, some of the former methods produced significantly biased estimates of sigma(y). The measured tracer concentration distributions were also crosswind integrated, chi(CWI). Estimates of chi(CWI) were computed using sigma (z) -values derived from the aforementioned computations assuming a Gaussian-type vertical tracer concentration distribution. A comparison is measured and calculated values of chi(CWI) showed no significant differences in the ability of the methods to predict the variation of chi(CWI). Only one method, the EPA, came out with a mean fractional error outside the range +-20% which constitutes the uncertainty in the absolute tracer concentration associated with the calibration of the gas chromatograph for tracer analysis

  15. sources

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  16. PLANETARY NEBULAE DETECTED IN THE SPITZER SPACE TELESCOPE GLIMPSE II LEGACY SURVEY

    Zhang Yong; Sun Kwok

    2009-01-01

    We report the result of a search for the infrared counterparts of 37 planetary nebulae (PNs) and PN candidates in the Spitzer Galactic Legacy Infrared Mid-Plane Survey Extraordinaire II (GLIMPSE II) survey. The photometry and images of these PNs at 3.6, 4.5, 5.8, 8.0, and 24 μm, taken through the Infrared Array Camera (IRAC) and the Multiband Imaging Photometer for Spitzer (MIPS), are presented. Most of these nebulae are very red and compact in the IRAC bands, and are found to be bright and extended in the 24 μm band. The infrared morphology of these objects are compared with Hα images of the Macquarie-AAO-Strasbourg (MASH) and MASH II PNs. The implications for morphological difference in different wavelengths are discussed. The IRAC data allow us to differentiate between PNs and H II regions and be able to reject non-PNs from the optical catalog (e.g., PNG 352.1 - 00.0). Spectral energy distributions are constructed by combing the IRAC and MIPS data with existing near-, mid-, and far-IR photometry measurements. The anomalous colors of some objects allow us to infer the presence of aromatic emission bands. These multi-wavelength data provide useful insights into the nature of different nebular components contributing to the infrared emission of PNs.

  17. Improved photoelectrochemical detection of mercury (II) with a TiO 2-modified composite photoelectrode

    Chamier, J

    2012-01-01

    Full Text Available The spectrophotometric change of amercury (II) (Hg2+) selective small molecule chemosensor has been successfully converted into a photovoltaic response upon ligating Hg2+. The photon excitation was followed by charge separation facilitated by TiO 2...

  18. Status report on the cold neutron source of the Garching neutron research facility FRM-II

    Gobrecht, K.; Gutsmiedl, E.; Scheuer, A.

    2002-01-01

    The new high flux research reactor of the Technical University of Munich (Technische Universität München, TUM) will be equipped with a cold neutron source (CNS). The centre of the CNS will be located in the D 2O-reflector tank at 400 mm from the reactor core axis close to the thermal neutron flux maximum. The power of 4500 W developed by the nuclear heating in the 16 l of liquid deuterium at 25 K, and in the structures, is evacuated by a two-phase thermal siphon avoiding film boiling and flooding. The thermal siphon is a single tube with counter current flow. It is inclined by 10° from vertical, and optimised for a deuterium flow rate of 14 g/s. Optimisation of structure design and material, as well as safety aspects will be discussed. Those parts of the structure, which are exposed to high thermal neutron flux, are made from Zircaloy 4 and 6061T6 aluminium. Structure failure due to embrittlement of the structure material under high rapid neutron flux is very improbable during the lifetime of the CNS (30 years). Double, in pile even triple, containment with inert gas liner guarantees lack of explosion risk and of tritium contamination to the environment. Adding a few percent of hydrogen (H 2) to the deuterium (D 2) will improve the moderating properties of our relatively small moderator volume. Nearly all of the hydrogen is bound in the form of HD molecules. A long-term change of the hydrogen content in the deuterium is avoided by storing the mixture not in a gas buffer volume but as a metal hydride at low pressure. The metal hydride storage system contains two getter beds, one with 250 kg of LaCo 3Ni 2, the other one with 150 kg of ZrCo 0.8Ni 0.2. Each bed can take the total gas inventory, both beds together can absorb the total gas inventory in cold (VCN) and ultra-cold neutron (UCN) production. The latter will take place in the horizontal beam tube SR4, which will house an additional cryogenic moderator (e.g. solid deuterium). More than 60% of the experiments

  19. Status report on the cold neutron source of the Garching neutron research facility FRM-II

    Gutsmiedl, E.; Gobrecht, K.

    2001-01-01

    The new high flux research reactor of the Technical University of Munich (Technische Universitaet Muenchen, TUM) will be equipped with a cold neutron source (CNS). The centre of the CNS will be located in the D2O-reflector tank at 400 mm from the reactor core axis, close to the thermal neutron flux maximum. The power of 4500 W developed by the nuclear heating in the 16 litres of liquid deuterium at 25 K, and in the structures, is evacuated by a two phase thermal siphon avoiding film boiling and flooding. The thermal siphon is a single tube with counter current flow. It is inclined by 10 from vertical, and optimised for a deuterium flow rate of 14 g/s. Optimisation of structure design and material, as well as safety aspects will be discussed. Those parts of the structure, which are exposed to high thermal neutron flux, are made from Zircaloy 4 and 6061T6 aluminium. Structure failure due to embrittlement of the structure material under high rapid neutron flux is very improbable during the life time of the CNS (30 years). Double, in pile even triple, containment with inert gas liner guarantees lack of explosion risk and of tritium contamination to the environment. Adding a few percent of hydrogen (H2) to the deuterium (D2) will improve the moderating properties of our relatively small moderator volume. Nearly all of the hydrogen is bound in the form of HD molecules. A long term change of the hydrogen content in the deuterium is avoided be storing the mixture not in a gas buffer volume but as a metal hydride at low pressure. The metal hydride storage system contains two getter beds, one with 250 kg of LaCo3Ni2, the other one with 150 kg of ZrCo(0.8)Ni(0.2). Each bed can take the total gas inventory, both beds together can absorb the total gas inventory in less than 6 minutes at a pressure < 3 bar. (orig.)

  20. NuSTAR, XMM-Newton and Suzaku Observations of the Ultraluminous X-Ray Source Holmberg II X-1

    Walton, D. J.; Middleton, M. J.; Rana, V.

    2015-01-01

    We present the first broadband 0.3-25.0 keV X-ray observations of the bright ultraluminous X-ray source (ULX) Holmberg II X-1, performed by NuSTAR, XMM-Newton, and Suzaku in 2013 September. The NuSTAR data provide the first observations of Holmberg II X-1 above 10 keV and reveal a very steep high...

  1. Flash-sourcing or the rapid detection and characterisation of earthquake effects through clickstream data analysis

    Bossu, R.; Mazet-Roux, G.; Roussel, F.; Frobert, L.

    2011-12-01

    crowd-to-agency system, but unlike them it is not based on declarative information (e.g. answers to a questionnaire) but on implicit data, clickstream observed on our website. We present first the main improvements of the method, improved detection of traffic surges, and a way to instantly map areas affected by severe damage or network disruptions. The second part describes how the derived information improves and fastens public earthquake information and, beyond seismology, what it can teach us on public behaviour when facing an earthquake. Finally, the discussion will focus on the future evolutions and how flash-sourcing could ultimately improve earthquake response.

  2. Electrochemical DNA biosensor for detection of porcine oligonucleotides using ruthenium(II) complex as intercalator label redox

    Halid, Nurul Izni Abdullah; Hasbullah, Siti Aishah; Heng, Lee Yook; Karim, Nurul Huda Abd [School of Chemical Sciences and Food Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan (Malaysia); Ahmad, Haslina; Harun, Siti Norain [Chemistry Department, Faculty of Science, Universiti Putra Malaysia, 43400, Serdang, Selangor (Malaysia)

    2014-09-03

    A DNA biosensor detection of oligonucleotides via the interactions of porcine DNA with redox active complex based on the electrochemical transduction is described. A ruthenium(II) complex, [Ru(bpy){sub 2}(PIP)]{sup 2+}, (bpy = 2,2′bipyridine, PIP = 2-phenylimidazo[4,5-f[[1,10-phenanthroline]) as DNA label has been synthesized and characterized by 1H NMR and mass spectra. The study was carried out by covalent bonding immobilization of porcine aminated DNA probes sequences on screen printed electrode (SPE) modified with succinimide-acrylic microspheres and [Ru(bpy){sub 2}(PIP)]{sup 2+} was used as electrochemical redox intercalator label to detect DNA hybridization event. Electrochemical detection was performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over the potential range where the ruthenium (II) complex was active. The results indicate that the interaction of [Ru(bpy){sub 2}(PIP)]{sup 2+} with hybridization complementary DNA has higher response compared to single-stranded and mismatch complementary DNA.

  3. Integrated ion imprinted polymers-paper composites for selective and sensitive detection of Cd(II) ions

    Huang, Kai [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Chen, Ying [Hubei Center for Disease Control and Prevention, No. 6 ZhuoDao Quan North Road, 430079, Wuhan (China); Zhou, Feng [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Zhao, Xiaoya [Hubei Entry-Exit Inspection and Quarantine Bureau of PRC, No.588 Qingtaidadao Road, Hubei, 430022, Wuhan (China); Liu, Jiafa [Hubei Center for Disease Control and Prevention, No. 6 ZhuoDao Quan North Road, 430079, Wuhan (China); Mei, Surong; Zhou, Yikai [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Jing, Tao, E-mail: jingtao@hust.edu.cn [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China)

    2017-07-05

    Highlights: • IIPs are first grafted on the low-cost A4 print paper to develop an integrated paper-based device. • As an imprinted composite, the adsorption capacity is 155.2 mg g{sup –1} and the imprinted factor is more than 3.0. • As an analytical method, the limit of detection is 0.4 ng mL{sup –1}. • Based on the water quality standards, it could be used to determine Cd(II) ions in drinking water. - Abstract: Paper-based sensor is a new alternative technology to develop a portable, low-cost, and rapid analysis system in environmental chemistry. In this study, ion imprinted polymers (IIPs) using cadmium ions as the template were directly grafted on the surface of low-cost print paper based on the reversible addition-fragmentation chain transfer polymerization. It can be applied as a recognition element to selectively capture the target ions in the complex samples. The maximum adsorption capacity of IIPs composites was 155.2 mg g{sup –1} and the imprinted factor was more than 3.0. Then, IIPs-paper platform could be also applied as a detection element for highly selective and sensitive detection of Cd(II) ions without complex sample pretreatment and expensive instrument, due to the selective recognition, formation of dithizone-cadmium complexes and light transmission ability. Under the optimized condition, the linear range was changed from 1 to 100 ng mL{sup –1} and the limit of detection was 0.4 ng mL{sup –1}. The results were in good agreement with the classic ICP-MS method. Furthermore, the proposed method can also be developed for detection of other heavy metals by designing of new IIPs.

  4. Rockfall hazard assessment integrating probabilistic physically based rockfall source detection (Norddal municipality, Norway).

    Yugsi Molina, F. X.; Oppikofer, T.; Fischer, L.; Hermanns, R. L.; Taurisano, A.

    2012-04-01

    Traditional techniques to assess rockfall hazard are partially based on probabilistic analysis. Stochastic methods has been used for run-out analysis of rock blocks to estimate the trajectories that a detached block will follow during its fall until it stops due to kinetic energy loss. However, the selection of rockfall source areas is usually defined either by multivariate analysis or by field observations. For either case, a physically based approach is not used for the source area detection. We present an example of rockfall hazard assessment that integrates a probabilistic rockfall run-out analysis with a stochastic assessment of the rockfall source areas using kinematic stability analysis in a GIS environment. The method has been tested for a steep more than 200 m high rock wall, located in the municipality of Norddal (Møre og Romsdal county, Norway), where a large number of people are either exposed to snow avalanches, rockfalls, or debris flows. The area was selected following the recently published hazard mapping plan of Norway. The cliff is formed by medium to coarse-grained quartz-dioritic to granitic gneisses of Proterozoic age. Scree deposits product of recent rockfall activity are found at the bottom of the rock wall. Large blocks can be found several tens of meters away from the cliff in Sylte, the main locality in the Norddal municipality. Structural characterization of the rock wall was done using terrestrial laser scanning (TLS) point clouds in the software Coltop3D (www.terranum.ch), and results were validated with field data. Orientation data sets from the structural characterization were analyzed separately to assess best-fit probability density functions (PDF) for both dip angle and dip direction angle of each discontinuity set. A GIS-based stochastic kinematic analysis was then carried out using the discontinuity set orientations and the friction angle as random variables. An airborne laser scanning digital elevation model (ALS-DEM) with 1 m

  5. High-sensitivity assay for Hg (II) and Ag (I) ion detection: A new class of droplet digital PCR logic gates for an intelligent DNA calculator.

    Cheng, Nan; Zhu, Pengyu; Xu, Yuancong; Huang, Kunlun; Luo, Yunbo; Yang, Zhansen; Xu, Wentao

    2016-10-15

    The first example of droplet digital PCR logic gates ("YES", "OR" and "AND") for Hg (II) and Ag (I) ion detection has been constructed based on two amplification events triggered by a metal-ion-mediated base mispairing (T-Hg(II)-T and C-Ag(I)-C). In this work, Hg(II) and Ag(I) were used as the input, and the "true" hierarchical colors or "false" green were the output. Through accurate molecular recognition and high sensitivity amplification, positive droplets were generated by droplet digital PCR and viewed as the basis of hierarchical digital signals. Based on this principle, YES gate for Hg(II) (or Ag(I)) detection, OR gate for Hg(II) or Ag(I) detection and AND gate for Hg(II) and Ag(I) detection were developed, and their sensitively and selectivity were reported. The results indicate that the ddPCR logic system developed based on the different indicators for Hg(II) and Ag(I) ions provides a useful strategy for developing advanced detection methods, which are promising for multiplex metal ion analysis and intelligent DNA calculator design applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. The Einstein@Home Gamma-ray Pulsar Survey. II. Source Selection, Spectral Analysis, and Multiwavelength Follow-up

    Wu, J.; Clark, C. J.; Pletsch, H. J.; Guillemot, L.; Johnson, T. J.; Torne, P.; Champion, D. J.; Deneva, J.; Ray, P. S.; Salvetti, D.; Kramer, M.; Aulbert, C.; Beer, C.; Bhattacharyya, B.; Bock, O.; Camilo, F.; Cognard, I.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Ferrara, E. C.; Kerr, M.; Machenschalk, B.; Ransom, S. M.; Sanpa-Arsa, S.; Wood, K.

    2018-02-01

    We report on the analysis of 13 gamma-ray pulsars discovered in the Einstein@Home blind search survey using Fermi Large Area Telescope (LAT) Pass 8 data. The 13 new gamma-ray pulsars were discovered by searching 118 unassociated LAT sources from the third LAT source catalog (3FGL), selected using the Gaussian Mixture Model machine-learning algorithm on the basis of their gamma-ray emission properties being suggestive of pulsar magnetospheric emission. The new gamma-ray pulsars have pulse profiles and spectral properties similar to those of previously detected young gamma-ray pulsars. Follow-up radio observations have revealed faint radio pulsations from two of the newly discovered pulsars and enabled us to derive upper limits on the radio emission from the others, demonstrating that they are likely radio-quiet gamma-ray pulsars. We also present results from modeling the gamma-ray pulse profiles and radio profiles, if available, using different geometric emission models of pulsars. The high discovery rate of this survey, despite the increasing difficulty of blind pulsar searches in gamma rays, suggests that new systematic surveys such as presented in this article should be continued when new LAT source catalogs become available.

  7. Laser Scribed Graphene Biosensor for Detection of Biogenic Amines in Food Samples Using Locally Sourced Materials

    Diana C. Vanegas

    2018-04-01

    Full Text Available In foods, high levels of biogenic amines (BA are the result of microbial metabolism that could be affected by temperatures and storage conditions. Thus, the level of BA is commonly used as an indicator of food safety and quality. This manuscript outlines the development of laser scribed graphene electrodes, with locally sourced materials, for reagent-free food safety biosensing. To fabricate the biosensors, the graphene surface was functionalized with copper microparticles and diamine oxidase, purchased from a local supermarket; and then compared to biosensors fabricated with analytical grade materials. The amperometric biosensor exhibits good electrochemical performance, with an average histamine sensitivity of 23.3 µA/mM, a lower detection limit of 11.6 µM, and a response time of 7.3 s, showing similar performance to biosensors constructed from analytical grade materials. We demonstrated the application of the biosensor by testing total BA concentration in fish paste samples subjected to fermentation with lactic acid bacteria. Biogenic amines concentrations prior to lactic acid fermentation were below the detection limit of the biosensor, while concentration after fermentation was 19.24 ± 8.21 mg histamine/kg, confirming that the sensor was selective in a complex food matrix. The low-cost, rapid, and accurate device is a promising tool for biogenic amine estimation in food samples, particularly in situations where standard laboratory techniques are unavailable, or are cost prohibitive. This biosensor can be used for screening food samples, potentially limiting food waste, while reducing chances of foodborne outbreaks.

  8. SELF-CONSISTENT EVOLUTION OF GAS AND COSMIC RAYS IN CYGNUS A AND SIMILAR FR II CLASSICAL DOUBLE RADIO SOURCES

    Mathews, William G.; Guo Fulai

    2010-01-01

    In Cygnus A and other classical FR II double radio sources, powerful opposing jets from the cores of halo-centered galaxies drive out into the surrounding cluster gas, forming hotspots of shocked and compressed cluster gas at the jet extremities. The moving hotspots are sandwiched between two shocks. An inner-facing shock receives momentum and cosmic rays from the jet and creates additional cosmic rays that form a radio lobe elongated along the jet axis. An outer-facing bow shock moves directly into the undisturbed group or cluster gas, creating a cocoon of shocked gas enclosing the radio lobe. We describe computations that follow the self-consistent dynamical evolution of the shocked cluster gas and the relativistic synchrotron-emitting gas inside the lobes. Relativistic and non-relativistic components exchange momentum by interacting with small magnetic fields having dynamically negligible energy densities. The evolution of Cygnus A is governed almost entirely by cosmic ray energy flowing from the hotspots. Mass flowing into hotspots from the jets is assumed to be small, greatly reducing the mass of gas flowing back along the jet, common in previous calculations, that would disrupt the spatial segregation of synchrotron-loss ages observed inside FR II radio lobes. We compute the evolution of the cocoon when the velocity and cosmic ray luminosity of the hotspots are constant and when they vary with time. If cosmic rays mix with cluster gas in hotspots before flowing into the radio lobe, the thermal gas is heated to mildly relativistic temperatures, producing an unobserved pressure inside the lobe.

  9. Detection of local sodium boiling in the nuclear boiling generator in KNK II and in the cores of SNR 300 and SNR 2

    Erhardt, J.; Hoppe, P.

    1977-03-01

    As a basis of a global detection system, the detection of local boiling in sodium cooled reactors via surveillance of the neutron flux background noise is of special importance. With the help of parameter studies it is investigated in the present report, which parts of the core of SNR 300 and SNR 2 could be monitored with such a detection system. As a comparison the detection sensibility of the planned boiling generator in KNK II is determined

  10. Distributed Leak Detection System Using Structure-Borne Noise, Phase II

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeoroid and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  11. Precise Automatic Image Coregistration Tools to Enable Pixel-Level Change Detection, Phase II

    National Aeronautics and Space Administration — Automated detection of land cover changes between multitemporal images (i.e., images captured at different times) has long been a goal of the remote sensing...

  12. Automated Manufacture of Damage Detecting, Self-Healing Composite Cryogenic Pressure Vessels, Phase II

    National Aeronautics and Space Administration — After successfully demonstrating the basic functionality of a damage-detecting, self-healing 'smart' material system in Phase I, Aurora and UMass Lowell aim to...

  13. Real breakthrough in detection of radioactive sources by portal monitors with plastic detectors and New Advanced Source Identification Algorithm (ASIA-New)

    Stavrov, Andrei; Yamamoto, Eugene [Rapiscan Systems, Inc., 14000 Mead Street, Longmont, CO, 80504 (United States)

    2015-07-01

    Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the Rapiscan company. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co- 57, Ba-133 and other). New variant of ASIA is based on physical principles, a phenomenological approach and analysis of some important parameter changes during the vehicle passage through the monitor control area. Thanks to this capability main advantage of new system is that this system can be easily installed into any RPM with plastic detectors. Taking into account that more than 4000 RPM has been installed worldwide their upgrading by ASIA-New may significantly increase probability of detection and verification of radioactive sources even masked by NORM. This algorithm was tested for 1,395 passages of

  14. Using Deep Learning for Gamma Ray Source Detection at the First G-APD Cherenkov Telescope (FACT)

    Bieker, Jacob

    2018-06-01

    Finding gamma-ray sources is of paramount importance for Imaging Air Cherenkov Telescopes (IACT). This study looks at using deep neural networks on data from the First G-APD Cherenkov Telescope (FACT) as a proof-of-concept of finding gamma-ray sources with deep learning for the upcoming Cherenkov Telescope Array (CTA). In this study, FACT’s individual photon level observation data from the last 5 years was used with convolutional neural networks to determine if one or more sources were present. The neural networks used various architectures to determine which architectures were most successful in finding sources. Neural networks offer a promising method for finding faint and extended gamma-ray sources for IACTs. With further improvement and modifications, they offer a compelling method for source detection for the next generation of IACTs.

  15. Point source detection using the Spherical Mexican Hat Wavelet on simulated all-sky Planck maps

    Vielva, P.; Martínez-González, E.; Gallegos, J. E.; Toffolatti, L.; Sanz, J. L.

    2003-09-01

    We present an estimation of the point source (PS) catalogue that could be extracted from the forthcoming ESA Planck mission data. We have applied the Spherical Mexican Hat Wavelet (SMHW) to simulated all-sky maps that include cosmic microwave background (CMB), Galactic emission (thermal dust, free-free and synchrotron), thermal Sunyaev-Zel'dovich effect and PS emission, as well as instrumental white noise. This work is an extension of the one presented in Vielva et al. We have developed an algorithm focused on a fast local optimal scale determination, that is crucial to achieve a PS catalogue with a large number of detections and a low flux limit. An important effort has been also done to reduce the CPU time processor for spherical harmonic transformation, in order to perform the PS detection in a reasonable time. The presented algorithm is able to provide a PS catalogue above fluxes: 0.48 Jy (857 GHz), 0.49 Jy (545 GHz), 0.18 Jy (353 GHz), 0.12 Jy (217 GHz), 0.13 Jy (143 GHz), 0.16 Jy (100 GHz HFI), 0.19 Jy (100 GHz LFI), 0.24 Jy (70 GHz), 0.25 Jy (44 GHz) and 0.23 Jy (30 GHz). We detect around 27 700 PS at the highest frequency Planck channel and 2900 at the 30-GHz one. The completeness level are: 70 per cent (857 GHz), 75 per cent (545 GHz), 70 per cent (353 GHz), 80 per cent (217 GHz), 90 per cent (143 GHz), 85 per cent (100 GHz HFI), 80 per cent (100 GHz LFI), 80 per cent (70 GHz), 85 per cent (44 GHz) and 80 per cent (30 GHz). In addition, we can find several PS at different channels, allowing the study of the spectral behaviour and the physical processes acting on them. We also present the basic procedure to apply the method in maps convolved with asymmetric beams. The algorithm takes ~72 h for the most CPU time-demanding channel (857 GHz) in a Compaq HPC320 (Alpha EV68 1-GHz processor) and requires 4 GB of RAM memory; the CPU time goes as O[NRoN3/2pix log(Npix)], where Npix is the number of pixels in the map and NRo is the number of optimal scales needed.

  16. Preparation, characterization and evaluation of water-soluble L-cysteine-capped-CdS nanoparticles as fluorescence probe for detection of Hg(II) in aqueous solution

    Cai Zhaoxia; Yang Hong; Zhang Yi; Yan Xiuping

    2006-01-01

    Water-soluble L-cysteine-capped-CdS nanoparticles were prepared in aqueous solution at room temperature through a straightforward one-pot process by using safe and low-cost inorganic salts as precursors, and characterized by transmission electron microscopy, X-ray diffraction spectrometry, Fourier transform infrared spectrometry, spectrofluorometry and ultraviolet-visible spectrometry. The prepared L-cysteine-capped-CdS nanoparticles were evaluated as fluorescence probe for Hg(II) detection. The fluorescence quenching of the L-cysteine-capped-CdS nanoparticles depended on the concentration and pH of Hg(II) solution. Maximum fluorescence quenching was observed at pH 7.4 with the excitation and emission wavelengths of 360 nm and 495 nm, respectively. Quenching of its fluorescence due to Hg(II) at the 20 nmol l -1 level was unaffected by the presence of 5 x 10 6 -fold excesses of Na(I) and K(I), 5 x 10 5 -fold excesses of Mg(II), 5 x 10 4 -fold excesses of Ca(II), 500-fold excesses of Al(III), 91-fold excesses of Mn(II), 23.5-fold excesses of Pb(II), 25-fold excesses of Fe(III), 25-fold excesses of Ag(I), 8.5-fold excesses of Ni(II) and 5-fold excesses of Cu(II). Under optimal conditions, the quenched fluorescence intensity increased linearly with the concentration of Hg(II) ranging from 16 nmol l -1 to 112 nmol l -1 . The limit of detection for Hg(II) was 2.4 nmol l -1 . The developed method was applied to the detection of trace Hg(II) in aqueous solutions

  17. Detection and identification of enteroviruses from various drinking water sources in Taiwan

    Hsu, Bing-Mu; Chen, Chien-Hsien; Wan, Min-Tao; Chang, Po-Jen; Fan, Cheng-Wei

    2009-02-01

    SummaryTwenty-three water samples, including seventeen from surface water reservoirs, three from the raw water of groundwater treatment plants, and three from small water systems, were collected in Taiwan and investigated for the presence of, as well as the species of enteroviruses. RT-PCR was used for the detection of enteroviruses. Results revealed that 23.5% of raw water samples from reservoirs were positive for enteroviruses. In addition, one of the three groundwater samples and two of the three small system water samples were positive for enteroviruses. Water samples that were positive for enteroviruses subsequently were evaluated by real-time PCR. The results indicated that enterovirus concentration in groundwater was lower than that in samples obtained from surface water sources. Enteroviruses were identified by nucleic acid sequencing in the 5'-untranslated regions. Three clusters of enteroviruses were identified as coxsackievirus A2, coxsackievirus A6, and enterovirus 71. The presence of enteroviruses indicates the possibility of waterborne transmission of enteroviruses in Taiwan, if water is not adequately treated.

  18. YAP scintillators for resonant detection of epithermal neutrons at pulsed neutron sources

    Tardocchi, M.; Gorini, G.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Rhodes, N.; Schooneveld, E. M.

    2004-01-01

    Recent studies indicate the resonance detector (RD) technique as an interesting approach for neutron spectroscopy in the electron volt energy region. This work summarizes the results of a series of experiments where RD consisting of YAlO 3 (YAP) scintillators were used to detect scattered neutrons with energy in the range 1-200 eV. The response of YAP scintillators to radiative capture γ emission from a 238 U analyzer foil was characterized in a series of experiments performed on the VESUVIO spectrometer at the ISIS pulsed neutron source. In these experiments a biparametric data acquisition allowed the simultaneous measurements of both neutron time-of-flight and γ pulse height (energy) spectra. The analysis of the γ pulse height and neutron time of flight spectra permitted to identify and distinguish the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the pulse height at about 600 keV equivalent photon energy. Present results strongly indicate YAP scintillators as the ideal candidate for neutron scattering studies with epithermal neutrons at both very low (<5 deg.) and intermediate scattering angles

  19. Early Detection of Apathetic Phenotypes in Huntington's Disease Knock-in Mice Using Open Source Tools.

    Minnig, Shawn; Bragg, Robert M; Tiwana, Hardeep S; Solem, Wes T; Hovander, William S; Vik, Eva-Mari S; Hamilton, Madeline; Legg, Samuel R W; Shuttleworth, Dominic D; Coffey, Sydney R; Cantle, Jeffrey P; Carroll, Jeffrey B

    2018-02-02

    Apathy is one of the most prevalent and progressive psychiatric symptoms in Huntington's disease (HD) patients. However, preclinical work in HD mouse models tends to focus on molecular and motor, rather than affective, phenotypes. Measuring behavior in mice often produces noisy data and requires large cohorts to detect phenotypic rescue with appropriate power. The operant equipment necessary for measuring affective phenotypes is typically expensive, proprietary to commercial entities, and bulky which can render adequately sized mouse cohorts as cost-prohibitive. Thus, we describe here a home-built, open-source alternative to commercial hardware that is reliable, scalable, and reproducible. Using off-the-shelf hardware, we adapted and built several of the rodent operant buckets (ROBucket) to test Htt Q111/+ mice for attention deficits in fixed ratio (FR) and progressive ratio (PR) tasks. We find that, despite normal performance in reward attainment in the FR task, Htt Q111/+ mice exhibit reduced PR performance at 9-11 months of age, suggesting motivational deficits. We replicated this in two independent cohorts, demonstrating the reliability and utility of both the apathetic phenotype, and these ROBuckets, for preclinical HD studies.

  20. RTNS-II: experience at 14-MeV source strengths between 1 x 1013 and 4 x 1013 n/s

    Davis, J.C.

    1986-05-01

    The design concepts, operational experience, and modifications of the two RTNS-II (Rotating Target Neutron Source-II) 14 MeV neutron sources are reviewed. The original design called for operation at a peak neutron source strength of 4 x 10 13 n/cm 2 s. The facility was to operate at high plant factor and at an acceptable cost in both dose delivered to operating staff and releases to the environment. The possibilities of higher source strengths are discussed in light of the operating experience to date and of new technologies that may be applied to the problems of high flux generators of this type. Changes in ancillary equipment that would provide more efficient or safe operation are also indicated

  1. Beamspace dual signal space projection (bDSSP): a method for selective detection of deep sources in MEG measurements

    Sekihara, Kensuke; Adachi, Yoshiaki; Kubota, Hiroshi K.; Cai, Chang; Nagarajan, Srikantan S.

    2018-06-01

    Objective. Magnetoencephalography (MEG) has a well-recognized weakness at detecting deeper brain activities. This paper proposes a novel algorithm for selective detection of deep sources by suppressing interference signals from superficial sources in MEG measurements. Approach. The proposed algorithm combines the beamspace preprocessing method with the dual signal space projection (DSSP) interference suppression method. A prerequisite of the proposed algorithm is prior knowledge of the location of the deep sources. The proposed algorithm first derives the basis vectors that span a local region just covering the locations of the deep sources. It then estimates the time-domain signal subspace of the superficial sources by using the projector composed of these basis vectors. Signals from the deep sources are extracted by projecting the row space of the data matrix onto the direction orthogonal to the signal subspace of the superficial sources. Main results. Compared with the previously proposed beamspace signal space separation (SSS) method, the proposed algorithm is capable of suppressing much stronger interference from superficial sources. This capability is demonstrated in our computer simulation as well as experiments using phantom data. Significance. The proposed bDSSP algorithm can be a powerful tool in studies of physiological functions of midbrain and deep brain structures.

  2. Realization of rapid debugging for detection circuit of optical fiber gas sensor: Using an analog signal source

    Tian, Changbin; Chang, Jun; Wang, Qiang; Wei, Wei; Zhu, Cunguang

    2015-03-01

    An optical fiber gas sensor mainly consists of two parts: optical part and detection circuit. In the debugging for the detection circuit, the optical part usually serves as a signal source. However, in the debugging condition, the optical part can be easily influenced by many factors, such as the fluctuation of ambient temperature or driving current resulting in instability of the wavelength and intensity for the laser; for dual-beam sensor, the different bends and stresses of the optical fiber will lead to the fluctuation of the intensity and phase; the intensity noise from the collimator, coupler, and other optical devices in the system will also result in the impurity of the optical part based signal source. In order to dramatically improve the debugging efficiency of the detection circuit and shorten the period of research and development, this paper describes an analog signal source, consisting of a single chip microcomputer (SCM), an amplifier circuit, and a voltage-to-current conversion circuit. It can be used to realize the rapid debugging detection circuit of the optical fiber gas sensor instead of optical part based signal source. This analog signal source performs well with many other advantages, such as the simple operation, small size, and light weight.

  3. Optimal Matched Filter in the Low-number Count Poisson Noise Regime and Implications for X-Ray Source Detection

    Ofek, Eran O.; Zackay, Barak

    2018-04-01

    Detection of templates (e.g., sources) embedded in low-number count Poisson noise is a common problem in astrophysics. Examples include source detection in X-ray images, γ-rays, UV, neutrinos, and search for clusters of galaxies and stellar streams. However, the solutions in the X-ray-related literature are sub-optimal in some cases by considerable factors. Using the lemma of Neyman–Pearson, we derive the optimal statistics for template detection in the presence of Poisson noise. We demonstrate that, for known template shape (e.g., point sources), this method provides higher completeness, for a fixed false-alarm probability value, compared with filtering the image with the point-spread function (PSF). In turn, we find that filtering by the PSF is better than filtering the image using the Mexican-hat wavelet (used by wavdetect). For some background levels, our method improves the sensitivity of source detection by more than a factor of two over the popular Mexican-hat wavelet filtering. This filtering technique can also be used for fast PSF photometry and flare detection; it is efficient and straightforward to implement. We provide an implementation in MATLAB. The development of a complete code that works on real data, including the complexities of background subtraction and PSF variations, is deferred for future publication.

  4. A curcumin-based TPA four-branched copper(II) complex probe for in vivo early tumor detection

    Pi, Zongxin [Department of Chemical and Chemical Engineering, Hefei Normal University, Hefei 230001 (China); Wang, Jiafeng; Jiang, Bo [Department of Pharmacy, Anhui University of Chinese Medicine, Hefei 230038 (China); Cheng, Gang [Department of Chemical and Chemical Engineering, Hefei Normal University, Hefei 230001 (China); Zhou, Shuangsheng, E-mail: zshuangsheng@126.com [Department of Pharmacy, Anhui University of Chinese Medicine, Hefei 230038 (China); Center of Modern Experimental Technology, Anhui University, Hefei 230038 (China)

    2015-01-01

    A multibranched Cu(II) complex CuL{sub 2} curcumin-based was synthesized and characterized by single-crystal X-ray diffraction analysis. The photophysical properties of the complex have been investigated both experimentally and theoretically. The results show that the target complex exhibits higher quantum yield and larger two-photon absorption (TPA) cross-section in the near infrared (NIR) region compared with its free ligand. The cell imaging studies in vitro and in vivo reveal that the complex shows good photostability and excellent tumor targeting capability to tested cancerous cells, which can be potentially used for early tumor detection. - Graphical abstract: A multibranched Cu(II) complex was prepared from curcumin. The photophysical properties of the obtained complex have been investigated. The results exhibit that the complex has high capability to test cancerous cells and can distinguish between the cancerous and noncancerous cells, which should be potentially used for early tumor detection. - Highlights: • A novel multi-branched copper complex was synthesized. • The obtained compounds exhibited obvious TPA in high polar solvents. • The complex is a low toxicity at low-micromolar concentrations. • The complex exhibits larger TPA cross-section and brighter TPF imaging. • The complex has excellent targeting capability to tested cancerous cells.

  5. Changing characteristics of the TDx digoxin II assay in detecting bufadienolides in a traditional Chinese medicine: for better or worse?

    Panesar, Nirmal S; Chan, Kam W; Law, Lap K

    2005-10-01

    In 1992, apparent digoxin concentrations determined by the Abbott TDx II assay 5 hours after the ingestion of 10 pills of traditional Chinese medicine containing toad secretions (chan su) by 7 volunteers, yielded results that were equimolar to bufalin measured by 2 in-house bufalin radioimmunoassays (RIAs). Recently, a 17-year-old Chinese female unintentionally took 100 (instead of 10) of these pills for a sore throat but suffered no ill effects. The blood bufalin concentration at 3 hours by 1 of the 2 RIAs was 10.93 nmol/L, which was commensurate with the dose. However, the apparent digoxin measured by a TDx II assay produced in 2004 was only 3.08 nmol/L, which probably reflects the change in the specificity of the polyclonal digoxin antisera used in the assay over the years. In 1989, the TDx assay was commended for its ability to detect poisoning from plant and animal cardenolides, a property that seems to be waning and, thus, bad news for those wishing to use the assay to detect alternative cardenolides. But, on the other hand, it possibly eliminates the "specter" of digoxin-like immunoreactive substance (DLIS) that has afflicted some digoxin assays, which can only be good news.

  6. Herschel-ATLAS: Dust Temperature and Redshift Distribution of SPIRE and PACS Detected Sources Using Submillimetre Colours

    Amblard, A.; Cooray, Asantha; Serra, P.; Temi, P.; Barton, E.; Negrello, M.; Auld, R.; Baes, M.; Baldry, I. K.; Bamford, S.; hide

    2010-01-01

    We present colour-colour diagrams of detected sources in the Herschel-ATLAS Science Demonstration Field from 100 to 500/microns using both PACS and SPIRE. We fit isothermal modified-blackbody spectral energy distribution (SED) models in order to extract the dust temperature of sources with counterparts in GAMA or SDSS with either a spectroscopic or a photometric redshift. For a subsample of 331 sources detected in at least three FIR bands with significance greater than 30 sigma, we find an average dust temperature of (28 plus or minus 8)K. For sources with no known redshifts, we populate the colour-colour diagram with a large number of SEDs generated with a broad range of dust temperatures and emissivity parameters and compare to colours of observed sources to establish the redshift distribution of those samples. For another subsample of 1686 sources with fluxes above 35 mJy at 350 microns and detected at 250 and 500 microns with a significance greater than 3sigma, we find an average redshift of 2.2 plus or minus 0.6.

  7. NEW APPROACHES IN DECEPTION DETECTION II. ACTIVE INTERVIEWING STRATEGIES AND CONTEXTUAL INFORMATION

    Jaume Masip

    2015-05-01

    Full Text Available Meta-analytical evidence shows that behavioural indicators of deception are scant, poorly diagnostic and inconsistent. This has yielded a shift in deception detection research. Rather than passively scrutinising the communication sender to find tell-tale behavioural indicators of deception, the deception judge needs to (a adopt an active role by using interviewing techniques specifically designed to detect deception, or (b focus on contextual (rather than behavioural deception cues. In the previous paper (Masip & Herrero, 2015a, we reviewed the antecedents of this change in focus, as well as the theoretical grounding of the new approaches. Here we describe specific interviewing strategies for detecting deception, as well as the (still scant research on contextual deception indicia. In doing this, we hope to offer the reader a detailed perspective on the recent developments in this specific area of psychology and law.

  8. A zinc fluorescent sensor used to detect mercury (II) and hydrosulfide.

    Jung, Jae Min; Lee, Jae Jun; Nam, Eunju; Lim, Mi Hee; Kim, Cheal; Harrison, Roger G

    2017-05-05

    A zinc sensor based on quinoline and morpholine has been synthesized. The sensor selectively fluoresces in the presence of Zn 2+ , while not for other metal ions. Absorbance changes in the 350nm region are observed when Zn 2+ binds, which binds in a 1:1 ratio. The sensor fluoresces due to Zn 2+ above pH values of 6.0 and in the biological important region. The Zn 2+ -sensor complex has the unique ability to detect both Hg 2+ and HS - . The fluorescence of the Zn 2+ -sensor complex is quenched when it is exposed to aqueous solutions of Hg 2+ with sub-micromolar detection levels for Hg 2+ . The fluorescence of the Zn 2+ -sensor complex is also quenched by aqueous solutions of hydrosulfide. The sensor was used to detect Zn 2+ and Hg 2+ in living cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Detection sensitivity of laser-induced breakdown spectroscopy for Cr II in liquid samples

    Rai, Nilesh K.; Rai, Awadhesh K.; Kumar, Akshaya; Thakur, Surya N.

    2008-01-01

    The performance of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of toxic metals such as Cr in water. Pure aqueous solutions (unitary matrix) with variable Cr concentration were used to construct calibration curves and to estimate the LIBS limit of detection (LOD). The calibration curves for Cr in a binary matrix (Cr plus Cd) and a tertiary matrix (Cr plus Cd and Co) were used to evaluate the matrix effect on the LOD. The LOD for Cr was found to be 1.1, 1.5, and 2.0 ppm (parts in 10 6 ) in a unitary, binary, and tertiary matrix, respectively. Once calibrated, the system was utilized for the detection and quantification of the Cr in tannery wastewater collected from different locations in the industrial area of Kanpur, India, where Cr concentrations were determined to be far higher than the U.S. Environmental Protection Agency safe drinking water limit of 0.05 ppm

  10. Fluid motion and solute distribution around sinking aggregates II : Implications for remote detection by colonizing zooplankters

    Kiørboe, Thomas; Thygesen, Uffe Høgsbro

    2001-01-01

    Marine snow aggregates are colonized by copepods, and encounter rates inferred from observed abundances of colonizers are high. We examined the potential for hydromechanical and chemical remote detection. The fluid disturbance generated by a sinking aggregate was described by solving the Navier......-Stokes' equation for a sinking sphere at Reynolds numbers typical of marine snow (up to 20). Fluid deformation rate, the component of the flow that can be perceived by copepods, attenuates rapidly, and detection distances estimated from knowledge of the hydromechanical sensitivity in copepods are insufficient...... to account for the observed abundances of colonizers. We next solved the advection-diffusion equation to describe the chemical trail left by a leaking and sinking aggregate. The plume is long and slender and may be detected by a horizontally cruising copepod. From the model of the plume and literature- based...

  11. Gold Nanoparticle-Based Detection of Hg(II) in an Aqueous Solution: Fluorescence Quenching and Surface-Enhanced Raman Scattering Study

    Ganbold, Erdene Ochir; Park, Jin Ho; Ock, Kwang Su; Joo, Sang Woo

    2011-01-01

    We studied the detection of the Hg(II) concentration in an aqueous solution using rhodamine dyes on citrate-reduced Au nanoparticles (NPs). The quenching effect from Au NPs was found to decrease as the Hg(II) concentration increased under our experimental conditions. As the fluorescence signals intensified, the surface-enhanced Raman scattering (SERS) intensities reduced on the contrary due to less rhodamine dyes on Au NPs as the Hg(II) concentration increased. The rhodamine 6G (Rh6G) and rhodamine 123 (Rh123) dyes were examined via fluorescence and SERS measurements depending on Hg(II) concentrations. Fast and easy fluorescence detection of an Hg (II) concentration as low as a few ppm could be achieved by naked eye using citrate-reduced Au NPs

  12. X-ray sources in regions of star formation. II. The pre-main-sequence G star HDE 283572

    Walter, F.M.; Brown, A.; Linsky, J.L.; Rydgren, A.E.; Vrba, F.; Joint Institute for Laboratory Astrophysics, Boulder, CO; Computer Sciences Corp., El Segundo, CA; Naval Observatory, Flagstaff, AZ)

    1987-01-01

    This paper reports the detection of HDE 283572, a ninth-magnitude G star 8 arcmin south of RY Tau, as a bright X-ray source. The observations reveal this object to be a fairly massive (about 2 solar masses) pre-main-sequence star associated with the Taurus-Auriga star formation complex. It exhibits few of the characteristics of the classical T Tauri stars and is a good example of a naked T Tauri star. The star is a mid-G subgiant, of about three solar radii and rotates with a period of 1.5 d. The coronal and chromospheric surface fluxes are similar to those of the most active late type stars (excluding T Tauri stars). The X-ray and UV lines most likely arise in different atmospheric structures. Radiative losses are some 1000 times the quiet solar value and compare favorably with those of T Tauri stars. 49 references

  13. The Status of Kasimov Chinggisids during the Reigns of Vasily II and Ivan III according to Written Sources

    M.A. Nesin

    2017-06-01

    Full Text Available Research objective: To study the issue both of the status of Kasimov Chinggisids as well as of the attitude toward the service Tatars and the Tatars who were allied to Moscow during the reigns of the great Moscow princes Vasily II and Ivan III. Research materials: Published and unpublished sources: books of official orders in the Russian state, chronicles, acts, diplomatic documents, etc. Results and novelty of the research: This work is the first comprehensive study of this topic. The author comes to the conclusion that Kasimov’s rulers during this period were considered servitors, vassals in relation to the Moscow principality. This was facilitated by the demesnial position of Kasimov, which was considered part of the grand prince’s domain rather than a sovereign splinter of the Golden Horde. Kasimov Chinggisids did not have a large military force in order to create an independent khanate in the steppe capable of competing, for example, with Kazan, and they relied on the strong Moscow principality performing military service for it, receiving money for proper maintenance and obeying the grand prince’s orders. At the same time, Ivan III even considered the possibility of replacing Daniyar in Kasimov with another serving prince during his lifetime. In addition, the author shows how much the attitude towards the service Tatars and the Tatar detachments, who were allied to Moscow, differed in different Russian lands.

  14. Tracking the MSL-SAM methane detection source location Through Mars Regional Atmospheric Modeling System (MRAMS)

    Pla-García, Jorge

    2016-04-01

    1. Introduction: The putative in situ detection of methane by Sample Analysis at Mars (SAM) instrument suite on Curiosi-ty at Gale crater has garnered significant attention because of the potential implications for the presence of geological methane sources or indigenous Martian organisms [1, 2]. SAM reported detection of back-ground levels of atmospheric methane of mean value 0.69±0.25 parts per billion by volume (ppbv) at the 95% confidence interval (CI). Additionally, in four sequential measurements spanning a 60-sol period, SAM observed elevated levels of methane of 7.2±2.1 ppbv (95% CI), implying that Mars is episodically producing methane from an additional unknown source. There are many major unresolved questions regard-ing this detection: 1) What are the potential sources of the methane release? 2) What causes the rapid decrease in concentration? and 3) Where is the re-lease location? 4) How spatially extensive is the re-lease? 5) For how long is CH4 released? Regarding the first question, the source of methane, is so far not identified. It could be related with geo-logical process like methane release from clathrates [3], serpentinisation [4] and volcanism [5]; or due to biological activity from methanogenesis [6]. To answer the second question, the rapid decrease in concentration, it is important to note that the photo-chemical lifetime of methane is of order 100 years, much longer than the atmospheric mixing time scale, and thus the gas should tend to be well mixed except near a source or shortly after an episodic release. The observed spike of 7 ppb from the background of System (MRAMS). The model was focused on rover locations using nested grids with a spacing of 330 meters on the in-nermost grid that is centered over the landing [8, 9]. MRAMS is ideally suited for this investigation; the model is explicitly designed to simulate Mars' at-mospheric circulations at the mesoscale and smaller with realistic, high-resolution surface properties [10, 11

  15. One-pot four-component synthesis of 2-aryl-3,3-dihaloacrylonitriles using potassium hexacyanoferrate(II) as environmentally benign cyanide source

    Zhao, Zhouxing; Li, Zheng

    2011-01-01

    An efficient route to one-pot four-component reactions of aroyl chlorides, potassium hexacyanoferrate(II), triphenylphosphine and carbon tetrahalides to synthesize 2-aryl-3,3-dichloroacrylonitriles and 2-aryl-3,3-dibromoacrylonitriles was described. This protocol has advantages of use of non-toxic cyanide source, high yield and simple work-up procedure. (author)

  16. Development of detection techniques for a single-particle of fissile material(II)

    Sohn, S. C.; Kim, W. H.; Park, Y. J.; Song, B. C.; Jeon, Y. S.; Jee, K. Y.; Pyo, H. Y.; Kwack, E. H

    2001-06-01

    The Analytical methods and detection limit of signatures, and the particle discrimination techniques of unknown particles by microscope were investigated in this technical report. In connection with pre-treatment of swipe samples, sampling and treatment of particles, etching method, fission track observation and the preparation of sample for the neutron activation analysis were also described in this thchnical report.

  17. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E

    The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...

  18. Development of detection techniques for a single-particle of fissile material(II)

    Sohn, S. C.; Kim, W. H.; Park, Y. J.; Song, B. C.; Jeon, Y. S.; Jee, K. Y.; Pyo, H. Y.; Kwack, E. H.

    2001-06-01

    The Analytical methods and detection limit of signatures, and the particle discrimination techniques of unknown particles by microscope were investigated in this technical report. In connection with pre-treatment of swipe samples, sampling and treatment of particles, etching method, fission track observation and the preparation of sample for the neutron activation analysis were also described in this thchnical report

  19. Damage detection using piezoelectric transducers and the Lamb wave approach: II. Robust and quantitative decision making

    Lu, Y; Wang, X; Tang, J; Ding, Y

    2008-01-01

    The propagation of Lamb waves generated by piezoelectric transducers in a one-dimensional structure has been studied comprehensively in part I of this two-paper series. Using the information embedded in the propagating waveforms, we expect to make a decision on whether damage has occurred; however, environmental and operational variances inevitably complicate the problem. To better detect the damage under these variances, we present in this paper a robust and quantitative decision-making methodology involving advanced signal processing and statistical analysis. In order to statistically evaluate the features in Lamb wave propagation in the presence of noise, we collect multiple time series (baseline signals) from the undamaged beam. A combination of the improved adaptive harmonic wavelet transform (AHWT) and the principal component analysis (PCA) is performed on the baseline signals to highlight the critical features of Lamb wave propagation in the undamaged structure. The detection of damage is facilitated by comparing the features of the test signal collected from the test structure (damaged or undamaged) with the features of the baseline signals. In this process, we employ Hotelling's T 2 statistical analysis to first purify the baseline dataset and then to quantify the deviation of the test data vector from the baseline dataset. Through experimental and numerical studies, we systematically investigate the proposed methodology in terms of the detectability (capability of detecting damage), the sensitivity (with respect to damage severity and excitation frequency) and the robustness against noises. The parametric studies also validate, from the signal processing standpoint, the guidelines of Lamb-wave-based damage detection developed in part I

  20. Synthesis of cysteamine-coated CdTe quantum dots and its application in mercury (II) detection

    Pei Jiying [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Department of Chemistry, University of Science and Technology of China (USTC), Hefei 230026 (China); Zhu Hui; Wang Xiaolei [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Zhang Hanchang [Department of Chemistry, University of Science and Technology of China (USTC), Hefei 230026 (China); Yang Xiurong, E-mail: xryang@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2012-12-13

    Highlights: Black-Right-Pointing-Pointer High-quality CA-CdTe QDs were synthesized with a kinetic-growth strategy. Black-Right-Pointing-Pointer The synthesis procedures were very simple. Black-Right-Pointing-Pointer The obtained QDs were used to detect Hg{sup 2+} without the interference of Cu{sup 2+}. - Abstract: High-quality cysteamine-coated CdTe quantum dots (CA-CdTe QDs) were successfully synthesized in aqueous phase by a facile one-pot method. Through hydroxylamine hydrochloride-promoted kinetic growth strategy, water-soluble CA-CdTe QDs could be obtained conveniently in a conical flask by a stepwise addition of raw materials. The photoluminescence quantum yield (PL QY) of the obtained QDs reached 9.2% at the emission peak of 520 nm. The optical property and the morphology of the QDs were characterized by UV-vis absorption spectra, photoluminescence spectra (PL) and transmission electron microscopy (TEM) respectively. Furthermore, the fluorescence of the resultant QDs was quenched by copper (II) (Cu{sup 2+}) and mercury (II) (Hg{sup 2+}) meanwhile. It is worthy of note that to separately detect Hg{sup 2+}, cyanide ion could be used to eliminate the interference of Cu{sup 2+}. Under the optimal conditions, the response was linearly proportional to the logarithm of Hg{sup 2+} concentration over the range of 0.08-3.33 {mu}M with a limit of detection (LOD) of 0.07 {mu}M.

  1. Observations of the Hubble Deep Field with the Infrared Space Observatory .2. Source detection and photometry

    Goldschmidt, P.; Oliver, S.J.; Serjeant, S.B.G.

    1997-01-01

    We present positions and fluxes of point sources found in the Infrared Space Observatory (ISO) images of the Hubble Deep Field (HDF) at 6.7 and 15 mu m. We have constructed algorithmically selected 'complete' flux-limited samples of 19 sources in the 15-mu m image, and seven sources in the 6.7-mu m...

  2. Vibrational effects of fuel elements detected during KNK II power operation

    Mitzel, F.; Vaeth, W.; Ansari, S.

    1982-08-01

    The reactivity signal of the KNK II reactor shows almost harmonic reactivity oscillations of Δρ≤0.5 cent. Sensitive correlation measurements, made during the regular plant operation with the normal out-of-core plant instrumentation, revealed that they are associated with individual fuel elements. Auxiliary measurements under various operational conditions and theoretical considerations showed that the oscillations are caused by flow-induced mechanical vibrations. Similar characteristics with respect to the frequencies of these oscillations have obviously not yet been observed for fuel element vibrations in other reactors and tests in out-of-core loops. Therefore efforts were made to classify the phenomenon and to identify the excitation mechanism by using only the normal plant instrumentation. It seems to be most likely a flow-induced vibration of whole fuel elements by vortex shedding or jet switching. This model can explain all observations without exception [de

  3. Quinoline-substituted Zinc(II) phthalocyanine for the dual detection of ferric and zinc ions

    Gupta, Ankush [Lyallpur Khalsa College of Engineering, Jalandhar (India); Kim, A Rong [Dong-A University, Busan (Korea, Republic of); Kim, Kyung Sub; Na, Kun [The Catholic University, Seoul (Korea, Republic of); Choi, Myung Seok [Konkuk University, Seoul (Korea, Republic of); Park, Jong S. [Pusan National University, Busan (Korea, Republic of)

    2015-09-15

    Here we present the synthesis and properties of quinoline-substituted zinc(II) phthalocyanine, Zn[Pc(O-QN){sub 4} ]. Zn[Pc(O-QN){sub 4} ] can function as a highly selective chemosensor against Fe{sup 3+} and Zn{sup 2+} ions, exhibiting efficient fluorescence quenching and enhancement, respectively. Various characterization techniques were employed to investigate the intermolecular interactions of Zn[Pc(O-QN){sub 4} ] with metal ions. A double-electron exchange and a forbidden photoinduced electron transfer behavior in Zn[Pc(O-QN){sub 4} ] were attributed to such opposite responses. Furthermore, by taking advantage of selectivity, we successfully employed Zn[Pc(O-QN)-4 ] to stain and record confocal fluorescence microscopy images of Chang liver cells in the presence of metal ions.

  4. dena grid study II. Integration of renewable energy sources into the German power supply system until 2020; dena - Netzstudie II. Integration erneuerbarer Energien in die deutsche Stromversorgung bis 2020

    Agricola, Annegret C.; Seidl, Hannes; Zoch, Immo (comps.)

    2010-12-15

    With its broad system approach, dena Grid Study II describes new ways of developing Germany's integrated grid with regard to the expansion of renewable energy sources and taking not only an economically optimised conventional power generation system but also European power trading into account. Basis for detailed grid planning. Having investigated many different transmission technologies, grid management measures and options for increasing flexibility on both the supply and demand side, the study does much more than simply identify grid expansion requirements, it shows the path towards overall optimisation of the energy supply system. In addition to robustly identifying grid expansion requirements, dena Grid Study II provides a very sound basis for further detailed grid planning and the identification of specific power routes in the German power transmission grid. Increasing grid expansion requirements. dena Grid Study II investigates the expansion of electricity generation from renewable energy sources to 39 percent by 2020. However, this is just an interim goal. By as soon as 2030, the German Federal Government is planning to raise the proportion of renewable electricity generation to 50 percent. This shows that even after 2020, further adaptation of grid infrastructure will still be necessary. Practical action required. If the grid expansion required to integrate renewable energy sources is to be achieved rapidly, there is an urgent need to back up the grid expansion scenarios presented in dena Grid Study II with practical action. (orig.)

  5. Measuring temporal summation in visual detection with a single-photon source.

    Holmes, Rebecca; Victora, Michelle; Wang, Ranxiao Frances; Kwiat, Paul G

    2017-11-01

    Temporal summation is an important feature of the visual system which combines visual signals that arrive at different times. Previous research estimated complete summation to last for 100ms for stimuli judged "just detectable." We measured the full range of temporal summation for much weaker stimuli using a new paradigm and a novel light source, developed in the field of quantum optics for generating small numbers of photons with precise timing characteristics and reduced variance in photon number. Dark-adapted participants judged whether a light was presented to the left or right of their fixation in each trial. In Experiment 1, stimuli contained a stream of photons delivered at a constant rate while the duration was systematically varied. Accuracy should increase with duration as long as the later photons can be integrated with the proceeding ones into a single signal. The temporal integration window was estimated as the point that performance no longer improved, and was found to be 650ms on average. In Experiment 2, the duration of the visual stimuli was kept short (100ms or photons was varied to explore the efficiency of summation over the integration window compared to Experiment 1. There was some indication that temporal summation remains efficient over the integration window, although there is variation between individuals. The relatively long integration window measured in this study may be relevant to studies of the absolute visual threshold, i.e., tests of single-photon vision, where "single" photons should be separated by greater than the integration window to avoid summation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. NuSTAR Hard X-Ray Survey of the Galactic Center Region. II. X-Ray Point Sources

    Hong, JaeSub; Mori, Kaya; Hailey, Charles J.

    2016-01-01

    persistent luminous X-ray binaries (XBs) and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr. A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra...

  7. Detecting Source Code Plagiarism on .NET Programming Languages using Low-level Representation and Adaptive Local Alignment

    Oscar Karnalim

    2017-01-01

    Full Text Available Even though there are various source code plagiarism detection approaches, only a few works which are focused on low-level representation for deducting similarity. Most of them are only focused on lexical token sequence extracted from source code. In our point of view, low-level representation is more beneficial than lexical token since its form is more compact than the source code itself. It only considers semantic-preserving instructions and ignores many source code delimiter tokens. This paper proposes a source code plagiarism detection which rely on low-level representation. For a case study, we focus our work on .NET programming languages with Common Intermediate Language as its low-level representation. In addition, we also incorporate Adaptive Local Alignment for detecting similarity. According to Lim et al, this algorithm outperforms code similarity state-of-the-art algorithm (i.e. Greedy String Tiling in term of effectiveness. According to our evaluation which involves various plagiarism attacks, our approach is more effective and efficient when compared with standard lexical-token approach.

  8. Effectively simultaneous naked-eye detection of Cu(II), Pb(II), Al(III) and Fe(III) using cyanidin extracted from red cabbage as chelating agent

    Khaodee, Warangkhana; Aeungmaitrepirom, Wanlapa; Tuntulani, Thawatchai

    Simultaneous determination of Cu(II), Pb(II), Al(III) and Fe(III) using cyanidin as a chelating agent was investigated in terms of both quantitative and qualitative detections. Cyanidin was extracted and purified from red cabbage which is a local plant in Thailand. The selectivity of this method was examined by regulating the pH of cyanidin solution operated together with masking agents. It was found that Cu(II), Pb(II), Al(III) and Fe(III) simultaneously responded with the color change at pH 7, pH 6, pH 5 and pH 4, respectively. KF, DMG and the mixture of KF and DMG were used as masking agents for the determination of Fe(III), Al(III) and Pb(II), respectively. Results from naked-eye detection were evaluated by comparing with those of inductively coupled plasma (ICP), and there was no significant difference noticed. Cyanidin using as a multianalyte reagent could be employed for simultaneous determination of Cu(II), Pb(II), Al(III) and Fe(III) at the lowest concentration at 50, 80, 50 and 200 μM, respectively, by slightly varying pHs. Moreover, the proposed method could be potentially applied for real water samples with simplicity, rapidity, low cost and environmental safety.

  9. Detection of a compact radio source near the center of a gravitational lens: quasar image or galactic core

    Gorenstein, M.V.; Shapiro, I.I.; Cohen, N.L.

    1983-01-01

    By use of a new, very sensitive interferometric system, a faint, compact radio source has been detected near the center of the galaxy that acts as the main part of a gravitational lens. This lens forms two previously discovered images of the quasar Q0957 + 561, which lies in the direction of the constellation Ursa Major. The newly detected source has a core smaller than 0.002 arc second in diameter with a flux density of 0.6 +- 0.1 millijansky at the 13-centimeter wavelength of the radio observations. This source could be the predicted third image of the transparent gravitational lens, the central core of the galaxy, or some combination of the two. It is not yet possible to choose reliably between these alternatives

  10. Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources

    Wei Zhang

    2018-02-01

    Full Text Available Water pollution has become one of the leading causes of human health problems. Low molecular weight pollutants, even at trace concentrations in water sources, have aroused global attention due to their toxicity after long-time exposure. There is an increased demand for appropriate methods to detect these pollutants in aquatic systems. Aptamers, single-stranded DNA or RNA, have high affinity and specificity to each of their target molecule, similar to antigen-antibody interaction. Aptamers can be selected using a method called Systematic Evolution of Ligands by EXponential enrichment (SELEX. Recent years we have witnessed great progress in developing aptamer selection and aptamer-based sensors for low molecular weight pollutants in water sources, such as tap water, seawater, lake water, river water, as well as wastewater and its effluents. This review provides an overview of aptamer-based methods as a novel approach for detecting low molecular weight pollutants in water sources.

  11. Detection of Copper (II) and Cadmium (II) binding to dissolved organic matter from macrophyte decomposition by fluorescence excitation-emission matrix spectra combined with parallel factor analysis

    Yuan, Dong-hai; Guo, Xu-jing; Wen, Li; He, Lian-sheng; Wang, Jing-gang; Li, Jun-qi

    2015-01-01

    Fluorescence excitation-emission matrix (EEM) spectra coupled with parallel factor analysis (PARAFAC) was used to characterize dissolved organic matter (DOM) derived from macrophyte decomposition, and to study its complexation with Cu (II) and Cd (II). Both the protein-like and the humic-like components showed a marked quenching effect by Cu (II). Negligible quenching effects were found for Cd (II) by components 1, 5 and 6. The stability constants and the fraction of the binding fluorophores for humic-like components and Cu (II) can be influenced by macrophyte decomposition of various weight gradients in aquatic plants. Macrophyte decomposition within the scope of the appropriate aquatic phytomass can maximize the stability constant of DOM-metal complexes. A large amount of organic matter was introduced into the aquatic environment by macrophyte decomposition, suggesting that the potential risk of DOM as a carrier of heavy metal contamination in macrophytic lakes should not be ignored. - Highlights: • Macrophyte decomposition increases fluorescent DOM components in the upper sediment. • Protein-like components are quenched or enhanced by adding Cu (II) and Cd (II). • Macrophyte decomposition DOM can impact the affinity of Cu (II) and Cd (II). • The log K M and f values showed a marked change due to macrophyte decomposition. • Macrophyte decomposition can maximize the stability constant of DOM-Cu (II) complexes. - Macrophyte decomposition DOM can influence on the binding affinity of metal ions in macrophytic lakes

  12. Change Detection for Remote Monitoring of Underground Nuclear Testing: Comparison with Seismic and Associated Explosion Source Phenomenological Data

    Canty, M.; Jahnke, G.; Nielsen, Allan Aasbjerg

    2005-01-01

    The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection of anthrop......The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection...... of conventional multispectral satellite platforms with moderate ground resolution (Landsat TM, ASTER) to detect changes over wide areas.We chose the Nevada Test Site (NTS), USA, for a case study because of the large amount of available ground truth information. The analysis is based on the multivariate alteration...

  13. Visual signal detection in structured backgrounds. II. Effects of contrast gain control, background variations, and white noise

    Eckstein, M. P.; Ahumada, A. J. Jr; Watson, A. B.

    1997-01-01

    Studies of visual detection of a signal superimposed on one of two identical backgrounds show performance degradation when the background has high contrast and is similar in spatial frequency and/or orientation to the signal. To account for this finding, models include a contrast gain control mechanism that pools activity across spatial frequency, orientation and space to inhibit (divisively) the response of the receptor sensitive to the signal. In tasks in which the observer has to detect a known signal added to one of M different backgrounds grounds due to added visual noise, the main sources of degradation are the stochastic noise in the image and the suboptimal visual processing. We investigate how these two sources of degradation (contrast gain control and variations in the background) interact in a task in which the signal is embedded in one of M locations in a complex spatially varying background (structured background). We use backgrounds extracted from patient digital medical images. To isolate effects of the fixed deterministic background (the contrast gain control) from the effects of the background variations, we conduct detection experiments with three different background conditions: (1) uniform background, (2) a repeated sample of structured background, and (3) different samples of structured background. Results show that human visual detection degrades from the uniform background condition to the repeated background condition and degrades even further in the different backgrounds condition. These results suggest that both the contrast gain control mechanism and the background random variations degrade human performance in detection of a signal in a complex, spatially varying background. A filter model and added white noise are used to generate estimates of sampling efficiencies, an equivalent internal noise, an equivalent contrast-gain-control-induced noise, and an equivalent noise due to the variations in the structured background.

  14. Zinc-sensitive MRI contrast agent detects differential release of Zn(II) ions from the healthy vs. malignant mouse prostate.

    Clavijo Jordan, M Veronica; Lo, Su-Tang; Chen, Shiuhwei; Preihs, Christian; Chirayil, Sara; Zhang, Shanrong; Kapur, Payal; Li, Wen-Hong; De Leon-Rodriguez, Luis M; Lubag, Angelo J M; Rofsky, Neil M; Sherry, A Dean

    2016-09-13

    Many secretory tissues release Zn(II) ions along with other molecules in response to external stimuli. Here we demonstrate that secretion of Zn(II) ions from normal, healthy prostate tissue is stimulated by glucose in fasted mice and that release of Zn(II) can be monitored by MRI. An ∼50% increase in water proton signal enhancement is observed in T1-weighted images of the healthy mouse prostate after infusion of a Gd-based Zn(II) sensor and an i.p. bolus of glucose. Release of Zn(II) from intracellular stores was validated in human epithelial prostate cells in vitro and in surgically exposed prostate tissue in vivo using a Zn(II)-sensitive fluorescent probe known to bind to the extracellular surface of cells. Given the known differences in intracellular Zn(II) stores in healthy versus malignant prostate tissues, the Zn(II) sensor was then evaluated in a transgenic adenocarcinoma of the mouse prostate (TRAMP) model in vivo. The agent proved successful in detecting small malignant lesions as early as 11 wk of age, making this noninvasive MR imaging method potentially useful for identifying prostate cancer in situations where it may be difficult to detect using current multiparametric MRI protocols.

  15. Possible use of tannin resins belonging to the luztan family in the Cd (II) sorption of watery sources

    Melchor, K.; Lima, L.; Luzardo, F. M.; Vargas, L. M.; Santana, J. L.; E.mail: keniamr@ctn.isctn.edu.cu

    2003-01-01

    There are studied the optimum sorption conditions of the Cd (II) in five different natural sorbent variants obtained from the tannin immobilization and re-immobilization in the vegetal bark of the species Ecualiptus saligna and Pinus caribea for being used to remove this metal from waste water. It was determined the sorption balance time of the Cd (II) in every sorbent, as well as, the corresponding sorption isotherms. The breakdown curves were obtained under dynamic conditions for the absorbents, that experienced a higher sorption for the Cd (II), from these curves, it was obtained the dynamic sorption capacity of them for the Cd (II)

  16. Detection of cerebral atrophy in type- II diabetes mellitus by magnetic resonance imaging of brain

    Khan, G.; Khan, N.; Aziz, A.

    2010-01-01

    Background: Diabetes is a metabolic disorder that affects many systems in the body. Cerebral atrophy is one of the complications of diabetes and research is on going to find out its aetiopathological factors. The main aim of the study was to determine the frequency of cerebral atrophy in type-II diabetes mellitus using magnetic resonance imaging of the brain. Methods: One hundred diabetic patients (Random blood sugar >126 mg/dl) were recruited in this study after the informed consent from every patient. Duration of diabetes was five years and more in all the patients as determined by their glycosylated haemoglobin which was >6 in all the patients. All the patients were undergone MRI of brain using 1.5 Tesla power magnetic resonance imaging machine of Picker Company. Evan's index, a specific parameter for measurement of cerebral atrophy was calculated on MR images and was used in this study. Results: In male group the frequency of cerebral atrophy was 22 (47%) and in female group it was found to be 23 (43%). When we study the overall population the frequency was found to be 45 (45%). The results are well in concordance with the previous data published on this issue. Conclusions: Cerebral atrophy, a complication of long standing diabetes is quite frequent in our population and is well diagnosed by MRI. (author)

  17. Highly sensitive amperometric sensor for micromolar detection of trichloroacetic acid based on multiwalled carbon nanotubes and Fe(II)–phtalocyanine modified glassy carbon electrode

    Kurd, Masoumeh; Salimi, Abdollah; Hallaj, Rahman

    2013-01-01

    A highly sensitive electrochemical sensor for the detection of trichloroacetic acid (TCA) is developed by subsequent immobilization of phthalocyanine (Pc) and Fe(II) onto multiwalled carbon nanotubes (MWCNTs) modified glassy carbon (GC) electrode. The GC/MWCNTs/Pc/Fe(II) electrode showed a pair of well-defined and nearly reversible redox couple correspondent to (Fe(III)Pc/Fe(II)Pc) with surface-confined characteristics. The surface coverage (Γ) and heterogeneous electron transfer rate constant (k s ) of immobilized Fe(II)–Pc were calculated as 1.26 × 10 −10 mol cm −2 and 28.13 s −1 , respectively. Excellent electrocatalytic activity of the proposed GC/MWCNTs/Pc/Fe(II) system toward TCA reduction has been indicated and the three consequent irreversible peaks for electroreduction of CCl 3 COOH to CH 3 COOH have been clearly seen. The observed chronoamperometric currents are linearly increased with the concentration of TCA at concentration range up to 20 mM. Detection limit and sensitivity of the modified electrode were 2.0 μM and 0.10 μA μM −1 cm −2 , respectively. The applicability of the sensor for TCA detection in real samples was tested. The obtained results suggest that the proposed system can serve as a promising electrochemical platform for TCA detection. Highlights: ► Phthalocyanine (PC) and Fe(II) immobilized onto MWCNTs modified GC electrode. ► A pair of well-defined redox couple correspondent to (Fe(III)Pc/Fe(II)Pc) observed. ► Modified electrode shows excellent catalytic activity to electroreduction of CCl 3 COOH. ► Amperometry and cyclic voltammetry techniques were used for detection of CCl 3 COOH. ► Detection limit and sensitivity were 2.0 μM and 0.10 μA μM −1 cm −2 , respectively

  18. Applications of Monte Carlo technique in the detection of explosives, narcotics and fissile material using neutron sources

    Sinha, Amar; Kashyap, Yogesh; Roy, Tushar; Agrawal, Ashish; Sarkar, P.S.; Shukla, Mayank

    2009-01-01

    The problem of illicit trafficking of explosives, narcotics or fissile materials represents a real challenge to civil security. Neutron based detection systems are being actively explored worldwide as a confirmatory tool for applications in the detection of explosives either hidden inside a vehicle or a cargo container or buried inside soil. The development of a system and its experimental testing is a tedious process and to develop such a system each experimental condition needs to be theoretically simulated. Monte Carlo based methods are used to find an optimized design for such detection system. In order to design such systems, it is necessary to optimize source and detector system for each specific application. The present paper deals with such optimization studies using Monte Carlo technique for tagged neutron based system for explosives and narcotics detection hidden in a cargo and landmine detection using backscatter neutrons. We will also discuss some simulation studies on detection of fissile material and photo-neutron source design for applications on cargo scanning. (author)

  19. Detection of hidden sources. Prompt reports by airborne teams in Resume95

    Toivonen, H.

    1997-01-01

    An exercise to locate and identify lost radioactive sources was arranged near Padasjoki Auttoinen village. Ten sources, consisting of caesium, cobolt, iridium and technetium, were hidden. The teams (10) were asked to report their findings immediately after the landing and 24 h later. The teams that had a large NaI detector at their disposal could locate more sources than the teams with HPGe detectors. However, for source identification and activity calculation and HPGe detector is superior. Thus, it is highly recommended for operational purposes that both measuring systems are used simultaneously. The best location results were provided by the Danish Emergency Management Agency; the team reported four sources at landing and two other sources were found in prompt data processing after the landing. (au)

  20. Detection of hidden sources. Prompt reports by airborne teams in Resume95

    Toivonen, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    An exercise to locate and identify lost radioactive sources was arranged near Padasjoki Auttoinen village. Ten sources, consisting of caesium, cobolt, iridium and technetium, were hidden. The teams (10) were asked to report their findings immediately after the landing and 24 h later. The teams that had a large NaI detector at their disposal could locate more sources than the teams with HPGe detectors. However, for source identification and activity calculation and HPGe detector is superior. Thus, it is highly recommended for operational purposes that both measuring systems are used simultaneously. The best location results were provided by the Danish Emergency Management Agency; the team reported four sources at landing and two other sources were found in prompt data processing after the landing. (au).

  1. Detection of hidden sources. Prompt reports by airborne teams in Resume95

    Toivonen, H [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1998-12-31

    An exercise to locate and identify lost radioactive sources was arranged near Padasjoki Auttoinen village. Ten sources, consisting of caesium, cobolt, iridium and technetium, were hidden. The teams (10) were asked to report their findings immediately after the landing and 24 h later. The teams that had a large NaI detector at their disposal could locate more sources than the teams with HPGe detectors. However, for source identification and activity calculation and HPGe detector is superior. Thus, it is highly recommended for operational purposes that both measuring systems are used simultaneously. The best location results were provided by the Danish Emergency Management Agency; the team reported four sources at landing and two other sources were found in prompt data processing after the landing. (au).

  2. FLICKERING OF 1.3 cm SOURCES IN SGR B2: TOWARD A SOLUTION TO THE ULTRACOMPACT H II REGION LIFETIME PROBLEM

    De Pree, C. G.; Monsrud, A. [Agnes Scott College, 141 East College Avenue, Decatur, GA 30030 (United States); Peters, T. [Institut für Theoretische Physik, Universität Zürich, CH-8057 Zürich (Switzerland); Mac Low, M.-M. [American Museum of Natural History, New York, NY 10024 (United States); Wilner, D. J.; Keto, E. R. [Harvard-Smithsonian CfA, Cambridge, MA 02138 (United States); Goss, W. M. [National Radio Astronomy Observatory, Socorro, NM 87801 (United States); Galván-Madrid, R. [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching (Germany); Klessen, R. S. [Zentrum für Astronomie, Institut für Theoretische Astrophysik, Universität Heidelberg, Albert-Ueberle-Str. 2, D-69120 Heidelberg (Germany)

    2014-02-01

    Accretion flows onto massive stars must transfer mass so quickly that they are themselves gravitationally unstable, forming dense clumps and filaments. These density perturbations interact with young massive stars, emitting ionizing radiation, alternately exposing and confining their H II regions. As a result, the H II regions are predicted to flicker in flux density over periods of decades to centuries rather than increase monotonically in size as predicted by simple Spitzer solutions. We have recently observed the Sgr B2 region at 1.3 cm with the Very Large Array in its three hybrid configurations (DnC, CnB, and BnA) at a resolution of ∼0.''25. These observations were made to compare in detail with matched continuum observations from 1989. At 0.''25 resolution, Sgr B2 contains 41 ultracompact (UC) H II regions, 6 of which are hypercompact. The new observations of Sgr B2 allow comparison of relative peak flux densities for the H II regions in Sgr B2 over a 23 year time baseline (1989-2012) in one of the most source-rich massive star forming regions in the Milky Way. The new 1.3 cm continuum images indicate that four of the 41 UC H II regions exhibit significant changes in their peak flux density, with one source (K3) dropping in peak flux density, and the other three sources (F10.303, F1, and F3) increasing in peak flux density. The results are consistent with statistical predictions from simulations of high mass star formation, suggesting that they offer a solution to the lifetime problem for UC H II regions.

  3. A luminescent Cd(II)-based metal-organic framework for detection of Fe(III) ions in aqueous solution

    Li, Fen-Fang; Zhu, Miao-Li; Lu, Li-Ping

    2018-05-01

    A novel Cd((II)-organic framework [Cd(Hcbic)]n (H3cbic = 1-(4-carboxybenz-yl)-1H-benzoim-idazole-5, 6-dicarboxylic acid) was assembled and characterized by X-ray single crystal analysis. The Cd-MOF features one-dimensional left and right-handed double helical chains with screw-pitch of about 4.727 Å and the 4-methyl benzoic acid groups of Hcbic2- ligands in MOF-1 play many ribbons distributing in the two sides of the 2D networks. It is found that MOF-1 shows high selectivity (KSV = 1.8 × 105 L / mol) for Fe3+ ions in water solution with luminescent quenching because of the existence of uncoordinated carboxyl groups within open frameworks, which indicates that MOF-1 is a simple and reliable detection sensing reagent for Fe3+ in practical applications.

  4. A highly selective fluorescence sensing platform for nanomolar Hg(II) detection based on cytosine derived quantum dot

    Luo, Liang; Song, Ting; Wang, Haoqiang; Yuan, Qunhui; Zhou, Shenghai

    2018-03-01

    Inspired by low toxicity and good biocompatibility of biomass derived quantum dot (QD), we herein developed a cytosine derived quantum dot, namely cyt-dot, via a one-step hydrothermal synthesis. The as-prepared cyt-dot emits blue fluorescence (FL) containing abundant oxygen (20.6 at.%) and nitrogen (24.1 at.%) contents. The cyt-dot based sensing platform shows exclusive selectivity for Hg(II) while being insensitive towards Fe(III) and Ag(I), which are important interference that usually cannot be ruled out. The detection limit for Hg(II) is of 11 nM, which is very close to the guideline value of 10 nM allowed by the U.S. Environmental Protection Agency in drinking water. In real water sample analyses, the present sensing platform can fulfil satisfied recoveries ranging from 100% to 108%. Besides, the acidity of solution has almost no effect on the sensing performance of the cyt-dot in a pH range of 5-8, suggesting its potential applications in sensing and bio-imaging.

  5. Toward the detection of gravitational waves under non-Gaussian noises II. Independent component analysis.

    Morisaki, Soichiro; Yokoyama, Jun'ichi; Eda, Kazunari; Itoh, Yousuke

    2016-01-01

    We introduce a new analysis method to deal with stationary non-Gaussian noises in gravitational wave detectors in terms of the independent component analysis. First, we consider the simplest case where the detector outputs are linear combinations of the inputs, consisting of signals and various noises, and show that this method may be helpful to increase the signal-to-noise ratio. Next, we take into account the time delay between the inputs and the outputs. Finally, we extend our method to nonlinearly correlated noises and show that our method can identify the coupling coefficients and remove non-Gaussian noises. Although we focus on gravitational wave data analysis, our methods are applicable to the detection of any signals under non-Gaussian noises.

  6. Rapid detection of illegal colorants on traditional Chinese pastries through mass spectrometry with an interchangeable thermal desorption electrospray ionization source.

    Chao, Yu-Ying; Chen, Yen-Ling; Chen, Wei-Chu; Chen, Bai-Hsiun; Huang, Yeou-Lih

    2018-06-30

    Ambient mass spectrometry using an interchangeable thermal desorption/electrospray ionization source (TD-ESI) is a relatively new technique that has had only a limited number of applications to date. Nevertheless, this direct-analysis technique has potential for wider use in analytical chemistry (e.g., in the rapid direct detection of contaminants, residues, and adulterants on and in food) when operated in dual-working mode (pretreatment-free qualitative screening and conventional quantitative confirmation) after switching to a TD-ESI source from a conventional ESI source. Herein, we describe the benefits and challenges associated with the use of a TD-ESI source to detect adulterants on traditional Chinese pastries (TCPs), as a proof-of-concept for the detection of illegal colorants. While TD-ESI can offer direct (i.e., without any sample preparation) qualitative screening analyses for TCPs with adequate sensitivity within 30 s, the use of TD-ESI for semi-quantification is applicable only for homogeneous matrices (e.g., tang yuan). Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Prevalence and methodologies for detection, characterization and subtyping of Listeria monocytogenes and L. ivanovii in foods and environmental sources

    Jin-Qiang Chen

    2017-09-01

    Full Text Available Listeria monocytogenes, one of the most important foodborne pathogens, can cause listeriosis, a lethal disease for humans. L. ivanovii, which is closely related to L. monocytogenes, is also widely distributed in nature and infects mainly warm-blooded ruminants, causing economic loss. Thus, there are high priority needs for methodologies for rapid, specific, cost-effective and accurate detection, characterization and subtyping of L. monocytogenes and L. ivanovii in foods and environmental sources. In this review, we (A described L. monocytogenes and L. ivanovii, world-wide incidence of listeriosis, and prevalence of various L. monocytogenes strains in food and environmental sources; (B comprehensively reviewed different types of traditional and newly developed methodologies, including culture-based, antigen/antibody-based, LOOP-mediated isothermal amplification, matrix-assisted laser desorption ionization-time of flight-mass spectrometry, DNA microarray, and genomic sequencing for detection and characterization of L. monocytogenes in foods and environmental sources; (C comprehensively summarized different subtyping methodologies, including pulsed-field gel electrophoresis, multi-locus sequence typing, ribotyping, and phage-typing, and whole genomic sequencing etc. for subtyping of L. monocytogenes strains from food and environmental sources; and (D described the applications of these methodologies in detection and subtyping of L. monocytogenes in foods and food processing facilities.

  8. Green synthesis of nitrogen-doped carbon dots from lotus root for Hg(II) ions detection and cell imaging

    Gu, Dan; Shang, Shaoming, E-mail: smshang@jiangnan.edu.cn; Yu, Qin; Shen, Jie

    2016-12-30

    Graphical abstract: Fluorescent nitrogen-doped carbon dots were synthesized by a facile, green, and fast microwave method, using lotus root as carbon source. These nitrogen-doped carbon dots can be used for Hg{sup 2+} detection and cell imaging. - Highlights: • A green, fast strategy for synthesizing carbon dots was established. • A simple, sensitive, selective and wide linear range sensing of Hg{sup 2+} was developed. • The sensor system was demonstrated to detect Hg{sup 2+} in environmental water sample. • The carbon dots could serve for multicolor fluorescence bioimaging. - Abstract: Herein, a facile, green, and fast method was developed in the synthesis of fluorescent nitrogen-doped carbon dots (CDs) with nitrogen content of 5.23%, using one-pot microwave treatment of lotus root (LR), without using any other surface passivation agents. The results show that these LR-CDs (with an average diameter of 9.41 nm) possess many outstanding features and have a high quantum yield of 19.0%. We further demonstrated applications of LR-CDs as probes for heavy metal ion detection. The LR-CDs exhibit captivating sensitivity and selectivity toward Hg{sup 2+} with a linear range from 0.1 to 60.0 μM and a detection limit of 18.7 nM. Eventually, the LR-CDs were applied for multicolor cell imaging, demonstrating their potential toward diverse applications.

  9. Improved Point-source Detection in Crowded Fields Using Probabilistic Cataloging

    Portillo, Stephen K. N.; Lee, Benjamin C. G.; Daylan, Tansu; Finkbeiner, Douglas P.

    2017-10-01

    Cataloging is challenging in crowded fields because sources are extremely covariant with their neighbors and blending makes even the number of sources ambiguous. We present the first optical probabilistic catalog, cataloging a crowded (˜0.1 sources per pixel brighter than 22nd mag in F606W) Sloan Digital Sky Survey r-band image from M2. Probabilistic cataloging returns an ensemble of catalogs inferred from the image and thus can capture source-source covariance and deblending ambiguities. By comparing to a traditional catalog of the same image and a Hubble Space Telescope catalog of the same region, we show that our catalog ensemble better recovers sources from the image. It goes more than a magnitude deeper than the traditional catalog while having a lower false-discovery rate brighter than 20th mag. We also present an algorithm for reducing this catalog ensemble to a condensed catalog that is similar to a traditional catalog, except that it explicitly marginalizes over source-source covariances and nuisance parameters. We show that this condensed catalog has a similar completeness and false-discovery rate to the catalog ensemble. Future telescopes will be more sensitive, and thus more of their images will be crowded. Probabilistic cataloging performs better than existing software in crowded fields and so should be considered when creating photometric pipelines in the Large Synoptic Survey Telescope era.

  10. Protection and fault detection for Lawrence Berkeley Laboratory neutral beam sources

    Hopkins, D.B.; Baker, W.R.; Berkner, K.H.; Ehlers, K.W.; Honey, V.J.; Lietzke, A.F.; Milnes, K.A.; Owren, H.M.

    1979-11-01

    Testing of TFTR neutral beam (NB) sources has begun at the LBL Neutral Beam System Test Facility (NBSTF). Operation at 120 kV, 65 A, 0.5 sec should be achieved soon. Because NB sources spark down frequently during conditioning, the main accelerating (accel) power supply must be interrupted within a few microseconds to avoid degrading the voltage holding capability, or even the damaging, of the NB source. A variety of improper magnitudes and/or ratios of voltages, currents, and times can occur and must be recognized as fault conditions in order to initiate a prompt interruption of the accel power supply. This paper discusses in detail the key signals which must be monitored and the manner in which they are processed in fault detector circuitry for safe operation of LBL NB sources. The paper also reviews the more standard interlocks and protective features recommended for these sources

  11. DETECTION OF CA II ABSORPTION BY A HIGH-VELOCITY CLOUD IN THE DIRECTION OF THE QUASAR PKS 0837-120

    ROBERTSON, JG; SCHWARZ, UJ; VANWOERDEN, H; MURRAY, JD; MORTON, DC; HULSBOSCH, ANM

    1991-01-01

    We present optical absorption spectroscopy of the Ca II K and H lines along the sight line to the quasar PKS 0837-120, which lies in the direction of a high-velocity cloud (HVC) detected in H I 21-cm emission at V(LSR) = + 105 km s-1. Our data show Ca II absorption due to the HVC as well as a lower

  12. THE SOURCE STRUCTURE OF 0642+449 DETECTED FROM THE CONT14 OBSERVATIONS

    Xu, Ming H.; Wang, Guang L.; Heinkelmann, Robert; Anderson, James M.; Mora-Diaz, Julian; Schuh, Harald

    2016-01-01

    The CONT14 campaign with state-of-the-art very long baseline interferometry (VLBI) data has observed the source 0642+449 with about 1000 observables each day during a continuous observing period of 15 days, providing tens of thousands of closure delays—the sum of the delays around a closed loop of baselines. The closure delay is independent of the instrumental and propagation delays and provides valuable additional information about the source structure. We demonstrate the use of this new “observable” for the determination of the structure in the radio source 0642+449. This source, as one of the defining sources in the second realization of the International Celestial Reference Frame, is found to have two point-like components with a relative position offset of −426 microarcseconds ( μ as) in R.A. and −66 μ as in decl. The two components are almost equally bright, with a flux-density ratio of 0.92. The standard deviation of closure delays for source 0642+449 was reduced from 139 to 90 ps by using this two-component model. Closure delays larger than 1 ns are found to be related to the source structure, demonstrating that structure effects for a source with this simple structure could be up to tens of nanoseconds. The method described in this paper does not rely on a priori source structure information, such as knowledge of source structure determined from direct (Fourier) imaging of the same observations or observations at other epochs. We anticipate our study to be a starting point for more effective determination of the structure effect in VLBI observations.

  13. THE SOURCE STRUCTURE OF 0642+449 DETECTED FROM THE CONT14 OBSERVATIONS

    Xu, Ming H.; Wang, Guang L. [Shanghai Astronomical Observatory, Chinese Academy of Sciences, No. 80 Nandan Raod, 200030, Shanghai (China); Heinkelmann, Robert; Anderson, James M.; Mora-Diaz, Julian; Schuh, Harald, E-mail: mhxu@shao.ac.cn [DeutschesGeoForschungsZentrum (GFZ), Potsdam, Telegrafenberg, D-14473 Potsdam (Germany)

    2016-11-01

    The CONT14 campaign with state-of-the-art very long baseline interferometry (VLBI) data has observed the source 0642+449 with about 1000 observables each day during a continuous observing period of 15 days, providing tens of thousands of closure delays—the sum of the delays around a closed loop of baselines. The closure delay is independent of the instrumental and propagation delays and provides valuable additional information about the source structure. We demonstrate the use of this new “observable” for the determination of the structure in the radio source 0642+449. This source, as one of the defining sources in the second realization of the International Celestial Reference Frame, is found to have two point-like components with a relative position offset of −426 microarcseconds ( μ as) in R.A. and −66 μ as in decl. The two components are almost equally bright, with a flux-density ratio of 0.92. The standard deviation of closure delays for source 0642+449 was reduced from 139 to 90 ps by using this two-component model. Closure delays larger than 1 ns are found to be related to the source structure, demonstrating that structure effects for a source with this simple structure could be up to tens of nanoseconds. The method described in this paper does not rely on a priori source structure information, such as knowledge of source structure determined from direct (Fourier) imaging of the same observations or observations at other epochs. We anticipate our study to be a starting point for more effective determination of the structure effect in VLBI observations.

  14. Expansion design for a Laboratory of Radioactive Sources Handling type II, class B; Diseno de ampliacion para un Laboratorio de Manejo de Fuentes Radiactivas tipo II, clase B

    Sanchez S, P. S.

    2014-07-01

    This work presents the expansion design of the Radioactive Wastes Research Laboratory (RWRL) installation authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico) as type II class C, to manage 40 different radionuclides, approximately. The RWRL has 4 areas at the present time: a laboratory of instrumental analysis, one of radioactive material processes, other of counting and a chemical reagents stock, which is not integrated to the operation license of the RWRL. With the purpose of expanding the operation license of the RWRL to an installation type II class B, to manage until 370 MBq of high radio toxicity radionuclides, is presented in this work an expansion proposal of the RWRL. The expansion proposal is based in: (1) the Mexican Nuclear Standard NOM-027-Nucl-1996 for installations type II class B, (2) the current distribution of water, light, electricity, extraction, gas, air and vacuum services of RWRL, and (3) the available areas inside the building that the RWRL occupies. The proposal contemplates the creation of additional new areas for RWRL: 3 laboratories, 2 dressing rooms, 2 bathrooms and 2 warehouses, one for radioactive materials and another for reagents chemical radiologically inactive. Architectural, electric, hydraulic, extraction and gas planes corresponding to the expansion of RWRL were realized. Inside the proposal the budget required to carry out the mentioned expansion is also presented. (Author)

  15. The detection of orphan radioactive sources and the regulatory attitude; La deteccion de fuentes radiactivas huerfanas y la actitud regulatoria

    Truppa, W.; Amodei, A.; Castro, L.; Rojas, C. [Autoridad Regulatoria Nuclear, Subgerencia Control de Instalaciones Radiactivas Clase ll y III, Av. Del Libertador 8250 Ciudad de Buenos Aires (C1429BNP) (Argentina)]. e-mail: wtruppa@sede.arn.gov.ar

    2006-07-01

    In the last decade, the appearance of orphan control radioactive sources has been one constant restlessness in the environment of the regulatory control. Of the well-known cases in the world the more common have been the appearance of type sources or industrial use, which by control lack, by negligence or abandonment were without the due protection and receipt. It is presented in this work the detection of a radioactive source of Cs-137 pickup among the scrap that entered to an important steelworks of the country, by a detector of portal type. Starting from there, Ia Nuclear Regulatory Authority (ARN) it carried out a deep investigation to determine the origin of the radioactive source, which drove to detect and to put low control to other three radioactive sources of the same type used in level measurement, originally housed in a tank of daily consumption of gas-oil, inside a craft that it was broken up for it sale like scrap. During the execution of these tasks they took the regulatory collection, chord to what indicates the normative of the Argentine Republic, harmonized by the international requirements as for the control of radioactive material. (Author)

  16. A study on multi-data source fusion method for petroleum pipeline leak detection

    Liang, Wei; Zhang, Laibin [Research Center of Oil and Gas Safety Engineering Technology, China University of Petroleum, Beijing, (China)

    2010-07-01

    The detection of leaks on petroleum pipeline is a very important safety issue. Several studies were commissioned to develop new monitoring procedures for leakage detection. This paper sets out a new leak detection process. The approach developed took into consideration steady and transient states. The study investigated leak diagnosis problems in product pipelines using multi-sensor measurements (pressure, flux, density and temperature). The information collected from each sensor was considered as pieces of evidence that describe the operational conditions of the pipeline. The Dempster-Shafer (D-S) theory is used to associate multi-sensor data to pipe health indices. Experimental pressure and flow rate data were recorded using a Pipeline Leak Detection System (PLDS) acquisition card and used to verify the accuracy and reliability of this new detection method. The results showed that the degree of credibility was a high as 0.877. It was also found that multi-feature information fusion improves recognition of pipeline conditions.

  17. Influence of multi-microphone signal enhancement algorithms on the acoustics and detectability of angular and radial source movements

    Lundbeck, Micha; Hartog, Laura; Grimm, Giso

    2018-01-01

    Hearing-impaired listeners are known to have difficulties not only with understanding speech in noise, but also with judging source distance and movement, and these deficits are related to perceived handicap. It is possible that the perception of spatially dynamic sounds can be improved...... with hearing aids (HAs), but so far this has not been investigated. In a previous study, older hearing-impaired (OHI) listeners showed poorer detectability for virtual left-right (angular) and near-far (radial) source movements due to lateral interfering sounds and reverberation, respectively (Lundbeck, Grimm...

  18. Semi-empirical Determination of Detection Efficiency for Voluminous Source by Effective Solid Angle Method

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In the field of γ-ray measurements, the determination of full energy (FE) absorption peak efficiency for a voluminous sample is difficult, because the preparation of the certified radiation source with the same chemical composition and geometry for the original voluminous sample is not easy. In order to solve this inconvenience, simulation or semi-empirical methods are preferred in many cases. Effective Solid Angle (ESA) Code which includes semi-empirical approach has been developed by the Applied Nuclear Physics Group in Seoul National University. In this study, we validated ESA code by using Marinelli type voluminous KRISS (Korea Research Institute of Standards and Science) CRM (Certified Reference Materials) sources and IAEA standard γ-ray point sources. And semi-empirically determined efficiency curve for voluminous source by using the ESA code is compared with the experimental value. We calculated the efficiency curve of voluminous source from the measured efficiency of standard point source by using the ESA code. We will carry out the ESA code validation by measurement of various CRM volume sources with detector of different efficiency.

  19. A selectively rhodamine-based colorimetric probe for detecting copper(II) ion.

    Zhang, Jiangang; Zhang, Li; Wei, Yanli; Chao, Jianbing; Shuang, Shaomin; Cai, Zongwei; Dong, Chuan

    2014-11-11

    A novel rhodamine derivative 3-bromo-5-methylsalicylaldehyde rhodamine B hydrazone (BMSRH) has been synthesized by reacting rhodamine B hydrazide with 3-bromo-5-methylsalicylaldehyde and developed as a new colorimetric probe for the selective and sensitive detection of Cu2+. Addition of Cu2+ to the solution of BMSRH results in a rapid color change from colorless to red together with an obvious new band appeared at 552 nm in the UV-vis absorption spectra. This change is attributed to the spirocycle form of BMSRH opened via coordination with Cu2+ in a 1:1 stoichiometry and their association constant is determined as 3.2×10(4) L mol(-1). Experimental results indicate that the BMSRH can provide a rapid, selective and sensitive response to Cu2+ with a linear dynamic range 0.667-240 μmol/L. Common interferent ions do not show any interference on the Cu2+ determination. It is anticipated that BMSRH can be a good candidate probe and has potential application for Cu2+ determination. The proposed probe exhibits the following advantages: a quick, simple and facile synthesis. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. TRANSITING PLANETS WITH LSST. II. PERIOD DETECTION OF PLANETS ORBITING 1 M{sub ⊙} HOSTS

    Jacklin, Savannah [Department of Astrophysics and Planetary Science, Villanova University, Villanova, PA 19085 (United States); Lund, Michael B.; Stassun, Keivan G. [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Pepper, Joshua [Department of Physics, Lehigh University, Bethlehem, PA 18015 (United States)

    2015-07-15

    The Large Synoptic Survey Telescope (LSST) will photometrically monitor ∼10{sup 9} stars for 10 years. The resulting light curves can be used to detect transiting exoplanets. In particular, as demonstrated by Lund et al., LSST will probe stellar populations currently undersampled in most exoplanet transit surveys, including out to extragalactic distances. In this paper we test the efficiency of the box-fitting least-squares (BLS) algorithm for accurately recovering the periods of transiting exoplanets using simulated LSST data. We model planets with a range of radii orbiting a solar-mass star at a distance of 7 kpc, with orbital periods ranging from 0.5 to 20 days. We find that standard-cadence LSST observations will be able to reliably recover the periods of Hot Jupiters with periods shorter than ∼3 days; however, it will remain a challenge to confidently distinguish these transiting planets from false positives. At the same time, we find that the LSST deep-drilling cadence is extremely powerful: the BLS algorithm successfully recovers at least 30% of sub-Saturn-size exoplanets with orbital periods as long as 20 days, and a simple BLS power criterion robustly distinguishes ∼98% of these from photometric (i.e., statistical) false positives.

  1. Detecting primordial gravitational waves with circular polarization of the redshifted 21 cm line. II. Forecasts

    Mishra, Abhilash; Hirata, Christopher M.

    2018-05-01

    In the first paper of this series, we showed that the CMB quadrupole at high redshifts results in a small circular polarization of the emitted 21 cm radiation. In this paper we forecast the sensitivity of future radio experiments to measure the CMB quadrupole during the era of first cosmic light (z ˜20 ). The tomographic measurement of 21 cm circular polarization allows us to construct a 3D remote quadrupole field. Measuring the B -mode component of this remote quadrupole field can be used to put bounds on the tensor-to-scalar ratio r . We make Fisher forecasts for a future Fast Fourier Transform Telescope (FFTT), consisting of an array of dipole antennas in a compact grid configuration, as a function of array size and observation time. We find that a FFTT with a side length of 100 km can achieve σ (r )˜4 ×10-3 after ten years of observation and with a sky coverage fsky˜0.7 . The forecasts are dependent on the evolution of the Lyman-α flux in the pre-reionization era, that remains observationally unconstrained. Finally, we calculate the typical order of magnitudes for circular polarization foregrounds and comment on their mitigation strategies. We conclude that detection of primordial gravitational waves with 21 cm observations is in principle possible, so long as the primordial magnetic field amplitude is small, but would require a very futuristic experiment with corresponding advances in calibration and foreground suppression techniques.

  2. Colorimetric detection of Hg(II) by measurement the color alterations from the "before" and "after" RGB images of etched triangular silver nanoplates.

    Li, Li; Zhang, Laiping; Zhao, Yan; Chen, Zhengbo

    2018-03-22

    It is shown that triangular silver nanoplates (TAgNPs) are viable colorimetric probes for the fast, sensitive and selective detection of Hg(II). Detection is accomplished by reducing Hg(II) ions to elemental Hg so that an Ag/Hg amalgam is formed on the surface of the TAgNPs. This leads to the inhibition of the etching TAgNPs by chloride ions. Correspondingly, a distinct color transition can be observed that goes from yellow to brown, purple, and blue. The color alterations extracted from the red, green, and blue part of digital (RGB) images can be applied to the determination of Hg(II). The relationship between the Euclidean distances (EDs), i.e. the square roots of the sums of the squares of the ΔRGB values, vary in the 5 nM to 100 nM Hg(II) concentration range, and the limit of detection is as low as 0.35 nM. The color changes also allow for a visual estimation of the concentrations of Hg(II). The method is simple in that it only requires a digital camera for data acquisition and a Photoshop software for extracting RGB variations and data processing. Graphical abstract Hg 2+ detection was achieved by anti-etching of TAgNPs caused by the formation of silver amalgam, along with vivid multicolor variations from yellow to brown, purple, and eventually to be blue.

  3. Comparing Natural Gas Leakage Detection Technologies Using an Open-Source "Virtual Gas Field" Simulator.

    Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R

    2016-04-19

    We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.

  4. Archival Legacy Investigations of Circumstellar Environments (ALICE): Statistical assessment of point source detections

    Choquet, Élodie; Pueyo, Laurent; Soummer, Rémi; Perrin, Marshall D.; Hagan, J. Brendan; Gofas-Salas, Elena; Rajan, Abhijith; Aguilar, Jonathan

    2015-09-01

    The ALICE program, for Archival Legacy Investigation of Circumstellar Environment, is currently conducting a virtual survey of about 400 stars, by re-analyzing the HST-NICMOS coronagraphic archive with advanced post-processing techniques. We present here the strategy that we adopted to identify detections and potential candidates for follow-up observations, and we give a preliminary overview of our detections. We present a statistical analysis conducted to evaluate the confidence level on these detection and the completeness of our candidate search.

  5. Nuclear Material Detection by One-Short-Pulse-Laser-Driven Neutron Source

    Favalli, Andrea; Aymond, F.; Bridgewater, Jon S.; Croft, Stephen; Deppert, O.; Devlin, Matthew James; Falk, Katerina; Fernandez, Juan Carlos; Gautier, Donald Cort; Gonzales, Manuel A.; Goodsell, Alison Victoria; Guler, Nevzat; Hamilton, Christopher Eric; Hegelich, Bjorn Manuel; Henzlova, Daniela; Ianakiev, Kiril Dimitrov; Iliev, Metodi; Johnson, Randall Philip; Jung, Daniel; Kleinschmidt, Annika; Koehler, Katrina Elizabeth; Pomerantz, Ishay; Roth, Markus; Santi, Peter Angelo; Shimada, Tsutomu; Swinhoe, Martyn Thomas; Taddeucci, Terry Nicholas; Wurden, Glen Anthony; Palaniyappan, Sasikumar; McCary, E.

    2015-01-01

    Covered in the PowerPoint presentation are the following areas: Motivation and requirements for active interrogation of nuclear material; laser-driven neutron source; neutron diagnostics; active interrogation of nuclear material; and, conclusions, remarks, and future works.

  6. Multi-Sensor Integration to Map Odor Distribution for the Detection of Chemical Sources

    Xiang Gao

    2016-07-01

    Full Text Available This paper addresses the problem of mapping odor distribution derived from a chemical source using multi-sensor integration and reasoning system design. Odor localization is the problem of finding the source of an odor or other volatile chemical. Most localization methods require a mobile vehicle to follow an odor plume along its entire path, which is time consuming and may be especially difficult in a cluttered environment. To solve both of the above challenges, this paper proposes a novel algorithm that combines data from odor and anemometer sensors, and combine sensors’ data at different positions. Initially, a multi-sensor integration method, together with the path of airflow was used to map the pattern of odor particle movement. Then, more sensors are introduced at specific regions to determine the probable location of the odor source. Finally, the results of odor source location simulation and a real experiment are presented.

  7. Detection of Nuclear Sources by UAV Teleoperation Using a Visuo-Haptic Augmented Reality Interface

    Jacopo Aleotti; Giorgio Micconi; Stefano Caselli; Giacomo Benassi; Nicola Zambelli; Manuele Bettelli; Andrea Zappettini

    2017-01-01

    A visuo-haptic augmented reality (VHAR) interface is presented enabling an operator to teleoperate an unmanned aerial vehicle (UAV) equipped with a custom CdZnTe-based spectroscopic gamma-ray detector in outdoor environments. The task is to localize nuclear radiation sources, whose location is unknown to the user, without the close exposure of the operator. The developed detector also enables identification of the localized nuclear sources. The aim of the VHAR interface is to increase the sit...

  8. Locating sensors for detecting source-to-target patterns of special nuclear material smuggling: a spatial information theoretic approach.

    Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong

    2010-01-01

    In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  9. Locating Sensors for Detecting Source-to-Target Patterns of Special Nuclear Material Smuggling: A Spatial Information Theoretic Approach

    Xuesong Zhou

    2010-08-01

    Full Text Available In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  10. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  11. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem; Wildi, Stefan; Bauerfeind, Peter

    2007-01-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  12. Improvement of bunch-by-bunch beam current detection system in Hefei light source

    Zheng Kai; Wang Junhua; Liu Zuping; Li Weimin; Zhou Zeran; Yang Yongliang; Huang Longjun; Chen Yuanbo

    2006-01-01

    Bunch-by-bunch beam current detection system is an important facility in the multibunch storage ring. In this paper, the established bunch-by-bunch beam current detection systems for the accelerator such as Cornell, SLAC and KEKB were compared and studied. The design of the bunch-by-bunch beam current detection system for HLS, which was based on the bunch-by-bunch tracing measurement system in HLS was given. Both demodulation by sine wave and square were applied in this paper, the deviation of the detect system was determined by the longitudinal oscillation. Compared the data acquired from ADC with the data from DCCT, the ADC data was scaled by the bunch current. The standard deviations of linear fit were about 1%, and the standard deviations of polynomial fit were less than 0.5% in both sine wave and square wave demodulation. Some analysis of the measurement results also had been shown in this paper. (authors)

  13. Sensitivities and detection limits of X-ray fluorescence analysis with a 10 mCi241Am source

    Wundt, K.; Janghorbani, M.; Starke, K.

    1976-01-01

    Seven trace elements ranging from chromium to barium were preconcentrated on Amberlite IR-120 cation exchange paper and determined in an energy dispersive X-ray fluorescence system using a 10 mCi 241 Am source. Sensitivities were experimentally determined and checked with theoretically calculated values. The detection limits are compared with elemental levels present in typical surface waters and those allowed in drinking water. Appropriate conclusions as to feasibility of such a system for environmental monitoring are drawn. (orig.) [de

  14. Multi-Source Fusion for Explosive Hazard Detection in Forward Looking Sensors

    2016-12-01

    California, United States Paper Title: Voxel-space radar signal processing for side attack explosive ballistic detection Publication Status: 1-Published...documentation. 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211...R-0012. The aim of this research is to improve the U.S. Army’s ability to detect landmines and explosive hazards in different scenarios using

  15. Elemental Composition of Mars Return Samples Using X-Ray Fluorescence Imaging at the National Synchrotron Light Source II

    Thieme, J.; Hurowitz, J. A.; Schoonen, M. A.; Fogelqvist, E.; Gregerson, J.; Farley, K. A.; Sherman, S.; Hill, J.

    2018-04-01

    NSLS-II at BNL provides a unique and critical capability to perform assessments of the elemental composition and the chemical state of Mars returned samples using synchrotron radiation X-ray fluorescence imaging and X-ray absorption spectroscopy.

  16. Compact quasi-monoenergetic photon sources from laser-plasma accelerators for nuclear detection and characterization

    Geddes, Cameron G.R., E-mail: cgrgeddes@lbl.gov; Rykovanov, Sergey; Matlis, Nicholas H.; Steinke, Sven; Vay, Jean-Luc; Esarey, Eric H.; Ludewigt, Bernhard; Nakamura, Kei; Quiter, Brian J.; Schroeder, Carl B.; Toth, Csaba; Leemans, Wim P.

    2015-05-01

    Near-monoenergetic photon sources at MeV energies offer improved sensitivity at greatly reduced dose for active interrogation, and new capabilities in treaty verification, nondestructive assay of spent nuclear fuel and emergency response. Thomson (also referred to as Compton) scattering sources are an established method to produce appropriate photon beams. Applications are however restricted by the size of the required high-energy electron linac, scattering (photon production) system, and shielding for disposal of the high energy electron beam. Laser-plasma accelerators (LPAs) produce GeV electron beams in centimeters, using the plasma wave driven by the radiation pressure of an intense laser. Recent LPA experiments are presented which have greatly improved beam quality and efficiency, rendering them appropriate for compact high-quality photon sources based on Thomson scattering. Designs for MeV photon sources utilizing the unique properties of LPAs are presented. It is shown that control of the scattering laser, including plasma guiding, can increase photon production efficiency. This reduces scattering laser size and/or electron beam current requirements to scale compatible with the LPA. Lastly, the plasma structure can decelerate the electron beam after photon production, reducing the size of shielding required for beam disposal. Together, these techniques provide a path to a compact photon source system.

  17. Self-assembled films containing crude extract of avocado as a source of tyrosinase for monophenol detection

    Vieira, Nirton C.S., E-mail: nirtoncristi@gmail.com [Instituto de Física de São Carlos/Universidade de São Paulo, CP 369, 13560-970 São Carlos, SP (Brazil); Ferreira, Reginaldo A. [Centro de Estudos e Inovação em Materiais Biofuncionais Avançados/Universidade Federal de Itajubá, CP 50, 37500-903 Itajubá, MG (Brazil); Cruz Rodrigues, Valquiria da; Guimarães, Francisco E.G. [Instituto de Física de São Carlos/Universidade de São Paulo, CP 369, 13560-970 São Carlos, SP (Brazil); Queiroz, Alvaro A.A. de [Centro de Estudos e Inovação em Materiais Biofuncionais Avançados/Universidade Federal de Itajubá, CP 50, 37500-903 Itajubá, MG (Brazil)

    2013-10-15

    This paper reports on the use of the crude extract of avocado (CEA) fruit (Persea americana) as a source of tyrosinase enzyme. CEA was immobilized via layer by layer (LbL) technique onto indium tin oxide (ITO) substrates and applied in the detection of monophenol using a potentiometric biosensor. Poly(propylene imine) dendrimer of generation 3 (PPI-G3) was used as a counter ion in the layer by layer process due to its highly porous structure and functional groups suitable for enzyme linkage. After the immobilization of the crude CEA as multilayered films, standard samples of monophenol were detected in the 0.25–4.00 mM linear range with approximately 28 mV mM{sup −1} of sensitivity. This sensitivity is 14 times higher than the values found in the literature for a similar system. The results show that it is possible to obtain efficient and low-cost biosensors for monophenol detection using potentiometric transducers and alternative sources of enzymes without purification. - Highlights: • ITO films were functionalized with multilayers of PPI dendrimer and crude extract of avocado. • The films were applied as potentiometric biosensor for the detection of monophenol. • The proposed system presented an excellent sensitivity to monophenol (27 mV mM{sup −1})

  18. Self-assembled films containing crude extract of avocado as a source of tyrosinase for monophenol detection

    Vieira, Nirton C.S.; Ferreira, Reginaldo A.; Cruz Rodrigues, Valquiria da; Guimarães, Francisco E.G.; Queiroz, Alvaro A.A. de

    2013-01-01

    This paper reports on the use of the crude extract of avocado (CEA) fruit (Persea americana) as a source of tyrosinase enzyme. CEA was immobilized via layer by layer (LbL) technique onto indium tin oxide (ITO) substrates and applied in the detection of monophenol using a potentiometric biosensor. Poly(propylene imine) dendrimer of generation 3 (PPI-G3) was used as a counter ion in the layer by layer process due to its highly porous structure and functional groups suitable for enzyme linkage. After the immobilization of the crude CEA as multilayered films, standard samples of monophenol were detected in the 0.25–4.00 mM linear range with approximately 28 mV mM −1 of sensitivity. This sensitivity is 14 times higher than the values found in the literature for a similar system. The results show that it is possible to obtain efficient and low-cost biosensors for monophenol detection using potentiometric transducers and alternative sources of enzymes without purification. - Highlights: • ITO films were functionalized with multilayers of PPI dendrimer and crude extract of avocado. • The films were applied as potentiometric biosensor for the detection of monophenol. • The proposed system presented an excellent sensitivity to monophenol (27 mV mM −1 )

  19. Evaluation of different analysis and identification methods for Salmonella detection in surface drinking water sources

    Hsu, Bing-Mu; Huang, Kuan-Hao; Huang, Shih-Wei; Tseng, Kuo-Chih; Su, Ming-Jen; Lin, Wei-Chen; Ji, Dar-Der; Shih, Feng-Cheng; Chen, Jyh-Larng; Kao, Po-Min

    2011-01-01

    The standard method for detecting Salmonella generally analyzes food or fecal samples. Salmonella often occur in relatively low concentrations in environmental waters. Therefore, some form of concentration and proliferation may be needed. This study compares three Salmonella analysis methods and develops a new Salmonella detection procedure for use in environmental water samples. The new procedure for Salmonella detection include water concentration, nutrient broth enrichment, selection of Salmonella containing broth by PCR, isolation of Salmonella strains by selective culture plates, detection of possible Salmonella isolate by PCR, and biochemical testing. Serological assay and pulsed-field gel electrophoresis (PFGE) can be used to identify Salmonella serotype and genotype, respectively. This study analyzed 116 raw water samples taken from 18 water plants and belonging to 5 watersheds. Of these 116, 10 water samples (8.6%) taken from 7 water plants and belonging to 4 watersheds were positive for a Salmonella-specific polymerase chain reaction targeting the invA gene. Guided by serological assay results, this study identified 7 cultured Salmonella isolates as Salmonella enterica serovar: Alnaby, Enteritidis, Houten, Montevideo, Newport, Paratyphi B var. Java, and Victoria. These seven Salmonella serovars were identified in clinical cases for the same geographical areas, but only one of them was 100% homologous with clinical cases in the PFGE pattern. - Research highlights: → A new Salmonella detecting procedure for environmental water is developed. → Salmonella isolates are identified by serological assay and PFGE. → A total of seven Salmonella serovars is isolated from environmental water.

  20. Evaluation of different analysis and identification methods for Salmonella detection in surface drinking water sources

    Hsu, Bing-Mu, E-mail: bmhsu@ccu.edu.tw [Department of Earth and Environmental Sciences, National Chung Cheng University, Chiayi, Taiwan, ROC (China); Huang, Kuan-Hao; Huang, Shih-Wei [Department of Earth and Environmental Sciences, National Chung Cheng University, Chiayi, Taiwan, ROC (China); Tseng, Kuo-Chih [Department of Internal Medicine, Buddhist Dalin Tzu Chi General Hospital, Chiayi, Taiwan, ROC (China); Su, Ming-Jen [Department of Clinical Pathology, Buddhist Dalin Tzu Chi General Hospital, Chiayi, Taiwan, ROC (China); Lin, Wei-Chen; Ji, Dar-Der [Research and Diagnostic Center, Centers for Disease Control, Taipei, Taiwan, ROC (China); Shih, Feng-Cheng; Chen, Jyh-Larng [Department of Environmental Engineering and Health, Yuanpei University of Science and Technology, HsinChu, Taiwan, ROC (China); Kao, Po-Min [Department of Earth and Environmental Sciences, National Chung Cheng University, Chiayi, Taiwan, ROC (China)

    2011-09-15

    The standard method for detecting Salmonella generally analyzes food or fecal samples. Salmonella often occur in relatively low concentrations in environmental waters. Therefore, some form of concentration and proliferation may be needed. This study compares three Salmonella analysis methods and develops a new Salmonella detection procedure for use in environmental water samples. The new procedure for Salmonella detection include water concentration, nutrient broth enrichment, selection of Salmonella containing broth by PCR, isolation of Salmonella strains by selective culture plates, detection of possible Salmonella isolate by PCR, and biochemical testing. Serological assay and pulsed-field gel electrophoresis (PFGE) can be used to identify Salmonella serotype and genotype, respectively. This study analyzed 116 raw water samples taken from 18 water plants and belonging to 5 watersheds. Of these 116, 10 water samples (8.6%) taken from 7 water plants and belonging to 4 watersheds were positive for a Salmonella-specific polymerase chain reaction targeting the invA gene. Guided by serological assay results, this study identified 7 cultured Salmonella isolates as Salmonella enterica serovar: Alnaby, Enteritidis, Houten, Montevideo, Newport, Paratyphi B var. Java, and Victoria. These seven Salmonella serovars were identified in clinical cases for the same geographical areas, but only one of them was 100% homologous with clinical cases in the PFGE pattern. - Research highlights: {yields} A new Salmonella detecting procedure for environmental water is developed. {yields} Salmonella isolates are identified by serological assay and PFGE. {yields} A total of seven Salmonella serovars is isolated from environmental water.

  1. Semi-empirical Calculation of Detection Efficiency for Voluminous Source Based on Effective Solid Angle Concept

    Kang, M. Y.; Kim, J. H.; Choi, H. D.; Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    To calculate the full energy (FE) absorption peak efficiency for arbitrary volume sample, we developed and verified the Effective Solid Angle (ESA) Code. The procedure for semi-empirical determination of the FE efficiency for the arbitrary volume sources and the calculation principles and processes about ESA code is referred to, and the code was validated with a HPGe detector (relative efficiency 32%, n-type) in previous studies. In this study, we use different type and efficiency of HPGe detectors, in order to verify the performance of the ESA code for the various detectors. We calculated the efficiency curve of voluminous source and compared with experimental data. We will carry out additional validation by measurement of various medium, volume and shape of CRM volume sources with detector of different efficiency and type. And we will reflect the effect of the dead layer of p-type HPGe detector and coincidence summing correction technique in near future.

  2. Developing laser ablation in an electron cyclotron resonance ion source for actinide detection with AMS

    Bauder, W. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Pardo, R.C.; Kondev, F.G.; Kondrashev, S.; Nair, C.; Nusair, O. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Palchan, T. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel); Scott, R.; Seweryniak, D.; Vondrasek, R. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Collon, P. [University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Paul, M. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel)

    2015-10-15

    A laser ablation material injection system has been developed at the ATLAS electron cyclotron resonance (ECR) ion source for use in accelerator mass spectrometry experiments. Beam production with laser ablation initially suffered from instabilities due to fluctuations in laser energy and cratering on the sample surface by the laser. However, these instabilities were rectified by applying feedback correction for the laser energy and rastering the laser across the sample surface. An initial experiment successfully produced and accelerated low intensity actinide beams with up to 1000 counts per second. With continued development, laser ablation shows promise as an alternative material injection scheme for ECR ion sources and may help substantially reduce cross talk in the source.

  3. Combined sensors for the detection, identification and monitoring of radiation sources

    Yaar, I.

    2006-01-01

    Radiation sources widely used in industry, medicine, agriculture. Research and education are the most dangerous from the viewpoint of their widespread and easy access.The probability that these sources will be stolen and used to assemble a radiological dispersive (RDD) is nor negligible. Such a device can be used by terrorist groups for the purpose of contamination of industrial centers, airports, seaports and residential areas, which can affect a large sector of the economy of a country. Detonation of a RDD can lead to death and exposure of the population to radiation, but, as a whole, the use of the bomb is aimed at creating panic among population, causing economic damage and social shock to the society. In this work, ways to reduce the threat of radiation sources obtained outside and within a country will be discussed

  4. Control of emissions from stationary combustion sources: Pollutant detection and behavior in the atmosphere

    Licht, W.; Engel, A.J.; Slater, S.M.

    1979-01-01

    Stationary combustion resources continue to be significant sources of NOx and SOx pollutants in the ambient atmosphere. This volume considers four problem areas: (1) control of emissions from stationary combustion sources, particularly SOx and NOx (2) pollutant behavior in the atmosphere (3) advances in air pollution analysis and (4) air quality management. Topics of interest include carbon slurries for sulfur dioxide abatement, mass transfer in the Kellogg-Weir air quality control system, oxidation/inhibition of sulfite ion in aqueous solution, some micrometeorological methods of measuring dry deposition rates, Spanish moss as an indicator of airborne metal contamination, and air quality impacts from future electric power generation in Texas

  5. Non-Darwinian evolution for the source detection of atmospheric releases

    Cervone, Guido; Franzese, Pasquale

    2011-08-01

    A non-Darwinian evolutionary algorithm is presented as search engine to identify the characteristics of a source of atmospheric pollutants, given a set of concentration measurements. The algorithm drives iteratively a forward dispersion model from tentative sources toward the real source. The solutions of non-Darwinian evolution processes are not generated through pseudo-random operators, unlike traditional evolutionary algorithms, but through a reasoning process based on machine learning rule generation and instantiation. The new algorithm is tested with both a synthetic case and with the Prairie Grass field experiment. To further test the capabilities of the algorithm to work in real-world scenarios, the source identification of all Prairie Grass releases was performed with a decreasing number of sensor measurements, and a relationship is found between the precision of the solution, the number of sensors available, and the levels of concentration measured by the sensors. The proposed methodology can be used for a variety of optimization problems, and is particularly suited for problems where the operations needed for evaluating new candidate solutions are computationally expensive.

  6. A systems approach for detecting sources of Phytophthora contamination in nurseries

    Jennifer L. Parke; Niklaus Grünwald; Carrie Lewis; Val Fieland

    2010-01-01

    Nursery plants are also important long-distance vectors of non-indigenous pathogens such as P. ramorum and P. kernoviae. Pre-shipment inspections have not been adequate to ensure that shipped plants are free from Phytophthora, nor has this method informed growers about sources of contamination in their...

  7. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    C. B. Alden

    2018-03-01

    Full Text Available Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m, integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB. The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1 a non-leaking source location and (2 a source location where a controlled emission of 3.1  ×  10−5 kg s−1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests. The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability and measurement uncertainty of 5 ppb (1σ, when

  8. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    Alden, Caroline B.; Ghosh, Subhomoy; Coburn, Sean; Sweeney, Colm; Karion, Anna; Wright, Robert; Coddington, Ian; Rieker, Gregory B.; Prasad, Kuldeep

    2018-03-01

    Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model-data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10-5 kg s-1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1σ), when measurements are averaged over 2 min. The

  9. Theory of the detection of the field surrounding half-dressed sources

    Compagno, G.; Passante, R.; Persico, F.

    1988-01-01

    Half-dressed sources are defined as sources deprived partially or totally of the cloud of virtual quanta which surrounds them in the ground state of the total system. Two models of a half-dressed point source S are considered, the first in the framework of the theory of massive scalar fields and the second in quantum electrodynamics (QED). In both cases the detector is modeled by a second fully dressed source T of the same field, which is also bound to an oscillation center by harmonic forces. It is shown that when S at time t = 0 is suddenly coupled to or decoupled from the field, the detector T, which is initially at rest, is set in motion after a time t = R 0 /c, where R 0 is the S-T distance. Neglecting the reaction back on the field due to the oscillatory motion of T, the amplitude of oscillation for t = ∞ is obtained as a function of R 0 . Thus the time-varying virtual field of S is shown to be capable of exerting a force which excites the model detector. For the QED case, this force is related to the properties of the energy density of the virtual field. This energy density displays a singularity at r = ct, and the mathematical nature of this singularity is studied in detail. In this way it is shown that the energy density of the time-dependent virtual field is rather different from that of a pulse of radiation emitted by a source during energy-conserving processes. The differences are discussed in detail, as well as the limitations of the model

  10. Silver nanoparticles deposited on amine-functionalized silica spheres and their amalgamation-based spectral and colorimetric detection of Hg(II) ions

    Rameshkumar, Perumal; Manivannan, Shanmugam; Ramaraj, Ramasamy, E-mail: ramarajr@yahoo.com [Madurai Kamaraj University, Centre for Photoelectrochemistry, School of Chemistry (India)

    2013-05-15

    A facile synthetic method to decorate amine-functionalized silica spheres (SiO{sub 2}) by silver nanoparticles (Ag NPs) is reported. The transmission electron microscopic (TEM) images showed that spherical Ag NPs with an average particle size of 14 nm were deposited on 250 nm-sized SiO{sub 2} spheres (SiO{sub 2}/Ag NPs). The spectral and colorimetric detection of Hg(II) ions were carried out using the synthesized SiO{sub 2}/Ag NPs with an experimental detection limit of 5 {mu}M. It was found that the addition of Hg(II) ions (150 {mu}M) into the solution of SiO{sub 2}/Ag NPs completely quenched the SPR band of the Ag NPs due to the formation of anisotropic Ag amalgam crystals (AgHg). The selective detection of Hg(II) ions by SiO{sub 2}/Ag NPs in the presence of other environmentally relevant metal ions was also demonstrated using spectral and colorimetric methods.Graphical abstractAmine-functionalized silica spheres are decorated by in situ formation of silver nanoparticles and their spectral and colorimetric detection of Hg(II) ions is reported.

  11. Pulsed Operation of a Compact Fusion Neutron Source Using a High-Voltage Pulse Generator Developed for Landmine Detection

    Yamauchi, Kunihito; Watanabe, Masato; Okino, Akitoshi; Kohno, Toshiyuki; Hotta, Eiki; Yuura, Morimasa

    2005-01-01

    Preliminary experimental results of pulsed neutron source based on a discharge-type beam fusion called Inertial Electrostatic Confinement Fusion (IECF) for landmine detection are presented. In Japan, a research and development project for constructing an advanced anti-personnel landmine detection system by using IECF, which is effective not only for metal landmines but also for plastic ones, is now in progress. This project consists of some R and D topics, and one of them is R and D of a high-voltage pulse generator system specialized for landmine detection, which can be used in the severe environment such as that in the field in Afghanistan. Thus a prototype of the system for landmine detection was designed and fabricated in consideration of compactness, lightness, cooling performance, dustproof and robustness. By using this prototype pulse generator system, a conventional IECF device was operated as a preliminary experiment. As a result, it was confirmed that the suggested pulse generator system is suitable for landmine detection system, and the results follow the empirical law obtained by the previous experiments. The maximum neutron production rate of 2.0x10 8 n/s was obtained at a pulsed discharge of -51 kV, 7.3 A

  12. Robust fault detection for the dynamics of high-speed train with multi-source finite frequency interference.

    Bai, Weiqi; Dong, Hairong; Yao, Xiuming; Ning, Bin

    2018-04-01

    This paper proposes a composite fault detection scheme for the dynamics of high-speed train (HST), using an unknown input observer-like (UIO-like) fault detection filter, in the presence of wind gust and operating noises which are modeled as disturbance generated by exogenous system and unknown multi-source disturbance within finite frequency domain. Using system input and system output measurements, the fault detection filter is designed to generate the needed residual signals. In order to decouple disturbance from residual signals without truncating the influence of faults, this paper proposes a method to partition the disturbance into two parts. One subset of the disturbance does not appear in residual dynamics, and the influence of the other subset is constrained by H ∞ performance index in a finite frequency domain. A set of detection subspaces are defined, and every different fault is assigned to its own detection subspace to guarantee the residual signals are diagonally affected promptly by the faults. Simulations are conducted to demonstrate the effectiveness and merits of the proposed method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Triple Quenching of a Novel Self-Enhanced Ru(II) Complex by Hemin/G-Quadruplex DNAzymes and Its Potential Application to Quantitative Protein Detection.

    Zhao, Min; Liao, Ni; Zhuo, Ying; Chai, Ya-Qin; Wang, Ji-Peng; Yuan, Ruo

    2015-08-04

    Herein, a novel "on-off" electrochemiluminescence (ECL) aptasensor for highly sensitive determination of thrombin has been constructed based on the triple quenching of the effect of hemin/G-quadruplex DNAzymes upon the Ru(II) complex-based ECL system. First, a strong initial ECL signal was achieved by the dual amplification strategies of (i) intramolecular coreaction of a self-enhanced Ru(II)-based molecule (PTCA-PEI-Ru(II)) and (ii) intermolecular coreaction between PTCA-PEI-Ru(II) and nicotinamide adenine dinucleotide (NADH), which was named the signal-on state. Then, a novel triple quenching of the effect of multifunctional hemin/G-quadruplex DNAzymes upon the Ru(II) complex-based ECL system was designed to realize the desirable signal-off state, which was outlined as follows: (i) the hemin/G-quadruplex DNAzymes mimicked NADH oxidase to oxidize NADH and in situ generate the H2O2, consuming the coreactant of NADH; (ii) its active center of hemin could oxidize the excited state PTCA-PEI-Ru(II)* to PTCA-PEI-Ru(III), making the energy and electron transfer quench; (iii) it also acted as horseradish peroxidase (HRP) to catalyze the H2O2 for in situ producing the quencher of O2. Based on triple quenching of the effect of hemin/G-quadruplex DNAzymes, the highly sensitive "on-off" thrombin aptasensor was developed with a wide linear detection range of 1.0 × 10(-14) M to 1.0 × 10(-10) M and a detection limit down to the femtomolar level.

  14. InGaAs/GaAsSb Type-II superlattice based photodiodes for short wave infrared detection

    Uliel, Y.; Cohen-Elias, D.; Sicron, N.; Grimberg, I.; Snapi, N.; Paltiel, Y.; Katz, M.

    2017-08-01

    Short Wave Infra-Red (SWIR) photodetectors operating above the response cutoff of InGaAs- based detectors (1.7-2.5 μm) are required for both defense and civil applications. Type II Super-Lattices (T2SL) were recently proposed For near- room temperature SWIR detection as a possible system enabling bandgap adjustment in the required range. The work presented here focuses on a T2SL with alternating nano-layers of InGaAs and GaAsSb lattice-matched to an InP substrate. A near room temperature SWIR cutoff of 2.4 μm was measured. Electrical junctions were realized using Zn diffusion p-doping process. We realized and studied both mesa- and selective diffusion- based p-i-n photodiodes. Dark currents of mesa-based devices were 1.5 mA/cm2 and 32 μA/cm2 at 300 and 230 K respectively. Dark currents were reduced to 1.2 mA/cm2 and 12 μA/cm2 respectively by utilizing the selective diffusion process. The effect of operating voltage is discussed. At 300 K the quantum efficiency was up to 40% at 2.18 μm in mesa devices. D∗ was 1.7 ×1010cm ·√{Hz } /W at 2 μm.

  15. Development of portable mass spectrometer with electron cyclotron resonance ion source for detection of chemical warfare agents in air.

    Urabe, Tatsuya; Takahashi, Kazuya; Kitagawa, Michiko; Sato, Takafumi; Kondo, Tomohide; Enomoto, Shuichi; Kidera, Masanori; Seto, Yasuo

    2014-01-01

    A portable mass spectrometer with an electron cyclotron resonance ion source (miniECRIS-MS) was developed. It was used for in situ monitoring of trace amounts of chemical warfare agents (CWAs) in atmospheric air. Instrumental construction and parameters were optimized to realize a fast response, high sensitivity, and a small body size. Three types of CWAs, i.e., phosgene, mustard gas, and hydrogen cyanide were examined to check if the mass spectrometer was able to detect characteristic elements and atomic groups. From the results, it was found that CWAs were effectively ionized in the miniECRIS-MS, and their specific signals could be discerned over the background signals of air. In phosgene, the signals of the 35Cl+ and 37Cl+ ions were clearly observed with high dose-response relationships in the parts-per-billion level, which could lead to the quantitative on-site analysis of CWAs. A parts-per-million level of mustard gas, which was far lower than its lethal dosage (LCt50), was successfully detected with a high signal-stability of the plasma ion source. It was also found that the chemical forms of CWAs ionized in the plasma, i.e., monoatomic ions, fragment ions, and molecular ions, could be detected, thereby enabling the effective identification of the target CWAs. Despite the disadvantages associated with miniaturization, the overall performance (sensitivity and response time) of the miniECRIS-MS in detecting CWAs exceeded those of sector-type ECRIS-MS, showing its potential for on-site detection in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Use of an external source (60Co) for 32P detection efficiency determination by the Cerenkov effect, in soil extracts

    Nascimento Filho, V.F. do.

    1975-03-01

    The detection of 32 P in aqueous extracts is usually made with the aid of a Geiger-Muller detector, with thin window and sample on a planchet. Presently the technique is being developed of detection of high energy beta particles emitters ( 32 P, 42 K, 86 Rb) through the Cerenkov effect, using a commercial liquid scintillation system. This technique, despite being approximately 30 times more sensitive, has the inconvenience of varying the detection efficiency, mainly for color samples (soil extracts, for instance). From this stems the need for determining the detection efficiency for each sample. The internal standardization and channels ratio methods show a series of drawbacks, mainly the non-reutilization of the samples (1st method) and statistical uncertainty for low activity samples (2nd method). The elimination of these dreawbacks can be achieved through the utilization of the external standardization method. A 60 Co source with 1,4 μCi activity has been adapted to the sample elevator of the detector system, and a comparison was made with the channels ratio method to evaluate the efficiency of 32 P detection in soil extracts (P extraction and fractionation). The external standardization method showed to be more accurate, besides being influenced to a lesser degree by high voltage variation, sample volume and vial types. In the case of large samples, it is advisable to carry out detection in vials filled up to their full capacity; in the case of small samples, the whole volume should be transferred to the vials and completed up to 9 ml for nylon vials,10 ml for glass vials and 11 to 14 ml for polyethilene vials. On the other hand, plastic vials showed higher detection efficiency than ones. As to background radiation, the lowest rates were given by nylon vials and the highest by Beckman glass vials [pt

  17. Fast and accurate detection of spread source in large complex networks.

    Paluch, Robert; Lu, Xiaoyan; Suchecki, Krzysztof; Szymański, Bolesław K; Hołyst, Janusz A

    2018-02-06

    Spread over complex networks is a ubiquitous process with increasingly wide applications. Locating spread sources is often important, e.g. finding the patient one in epidemics, or source of rumor spreading in social network. Pinto, Thiran and Vetterli introduced an algorithm (PTVA) to solve the important case of this problem in which a limited set of nodes act as observers and report times at which the spread reached them. PTVA uses all observers to find a solution. Here we propose a new approach in which observers with low quality information (i.e. with large spread encounter times) are ignored and potential sources are selected based on the likelihood gradient from high quality observers. The original complexity of PTVA is O(N α ), where α ∈ (3,4) depends on the network topology and number of observers (N denotes the number of nodes in the network). Our Gradient Maximum Likelihood Algorithm (GMLA) reduces this complexity to O (N 2 log (N)). Extensive numerical tests performed on synthetic networks and real Gnutella network with limitation that id's of spreaders are unknown to observers demonstrate that for scale-free networks with such limitation GMLA yields higher quality localization results than PTVA does.

  18. Detection of anomalies in radio tomography of asteroids: Source count and forward errors

    Pursiainen, S.; Kaasalainen, M.

    2014-09-01

    The purpose of this study was to advance numerical methods for radio tomography in which asteroid's internal electric permittivity distribution is to be recovered from radio frequency data gathered by an orbiter. The focus was on signal generation via multiple sources (transponders) providing one potential, or even essential, scenario to be implemented in a challenging in situ measurement environment and within tight payload limits. As a novel feature, the effects of forward errors including noise and a priori uncertainty of the forward (data) simulation were examined through a combination of the iterative alternating sequential (IAS) inverse algorithm and finite-difference time-domain (FDTD) simulation of time evolution data. Single and multiple source scenarios were compared in two-dimensional localization of permittivity anomalies. Three different anomaly strengths and four levels of total noise were tested. Results suggest, among other things, that multiple sources can be necessary to obtain appropriate results, for example, to distinguish three separate anomalies with permittivity less or equal than half of the background value, relevant in recovery of internal cavities.

  19. Characterization of sealed radioactive sources. Uncertainty analysis to improve detection methods

    Cummings, D.G.; Sommers, J.D.; Adamic, M.L.; Jimenez, M.; Giglio, J.J.; Carney, K.P.

    2009-01-01

    A radioactive 137 Cs source has been analyzed for the radioactive parent 137 Cs and stable decay daughter 137 Ba. The ratio of the daughter to parent atoms is used to estimate the date when Cs was purified prior to source encapsulation (an 'age' since purification). The isotopes were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) after chemical separation. In addition, Ba was analyzed by isotope dilution ICP-MS (ID-ICP-MS). A detailed error analysis of the mass spectrometric work has been undertaken to identify areas of improvement, as well as quantifying the effect the errors have on the 'age' determined. This paper reports an uncertainty analysis to identifying areas of improvement and alternative techniques that may reduce the uncertainties. In particular, work on isotope dilution using ICP-MS for the 'age' determination of sealed sources is presented. The results will be compared to the original work done using external standards to calibrate the ICP-MS instrument. (author)

  20. Stories about breast cancer in Australian women's magazines: information sources for risk, early detection and treatment.

    Wilkes, L; Withnall, J; Harris, R; White, K; Beale, B; Hobson, J; Durham, M; Kristjanson, L

    2001-06-01

    Sixty articles in five Australian women's magazines were analyzed for journalistic qualities, metaphors, narrative features and accuracy of clinical facts related to risk, early detection and treatment of breast cancer. The stories were features, news features or soft news stories. The stories reflected the 'good news' editorial style of women's magazines. A dominant theme in the stories was that early detection of breast cancer is crucial and equals survival. While there were few inaccuracies in the stories, there was little detail of treatment modalities, an emphasis on lifestyle as a risk factor and a prevailing message that a genetic history of breast cancer means you will get it. A major implication of the findings is that nurses, who provide information to women, must be aware of the goals of journalists and the educational power of narrative logic of stories in women's magazines.

  1. Highly sensitive time resolved singlet oxygen luminescence detection using LEDs as the excitation source

    Hackbarth, S; Schlothauer, J; Preuss, A; Röder, B

    2013-01-01

    For the first time singlet oxygen luminescence kinetics in living cells were detected at high precision using LED light for excitation. As LED technology evolves, the light intensity emitted by standard LEDs allows photosensitized singlet oxygen luminescence detection in solution and cell suspensions. We present measurements superior to those of most actual laser powered setups regarding precision of singlet oxygen kinetics in solutions and cell suspensions. Data presented here show that LED based setups allow the determination of the photosensitizer triplet and singlet oxygen decay times in vitro with an accuracy of 0.1 μs. This enables monitoring of the photosensitizer efficiency and interaction with the cellular components using illumination doses small enough not to cause cell death. (letter)

  2. Study on development and actual application of scientific crime detection technique using small scale neutron radiation source

    Suzuki, Yasuhiro; Kishi, Toru; Tachikawa, Noboru; Ishikawa, Isamu.

    1997-01-01

    PGA (Prompt γ-ray Analysis) is an analytic method of γ-ray generated from atomic nuclei of elements in the specimen just after irradiation (within 10(exp-14)sec.) of neutron to it. As using neutron with excellent transmission for an exciting source, this method can be used for inspecting the matters in closed containers non-destructively, and can also detect non-destructively light elements such as boron, nitrogen and others difficult by other non-destructive analysis. Especially, it is found that this method can detect such high concentration of nitrogen, chlorine and others which are characteristic elements for the explosives. However, as there are a number of limitations at the nuclear reactor site, development of an analytical apparatus for small scale neutron radiation source was begun, at first. In this fiscal year, analysis of the light elements such as nitrogen, chlorine and others using PGA was attempted by using 252-Cf as the simplest neutron source in its operation. As the 252-Cf neutron flux was considerably lower than that of nuclear reactor, its analytical sensitivity was also investigated. (G.K.)

  3. Developing an Open Source, Reusable Platform for Distributed Collaborative Information Management in the Early Detection Research Network

    Hart, Andrew F.; Verma, Rishi; Mattmann, Chris A.; Crichton, Daniel J.; Kelly, Sean; Kincaid, Heather; Hughes, Steven; Ramirez, Paul; Goodale, Cameron; Anton, Kristen; hide

    2012-01-01

    For the past decade, the NASA Jet Propulsion Laboratory, in collaboration with Dartmouth University has served as the center for informatics for the Early Detection Research Network (EDRN). The EDRN is a multi-institution research effort funded by the U.S. National Cancer Institute (NCI) and tasked with identifying and validating biomarkers for the early detection of cancer. As the distributed network has grown, increasingly formal processes have been developed for the acquisition, curation, storage, and dissemination of heterogeneous research information assets, and an informatics infrastructure has emerged. In this paper we discuss the evolution of EDRN informatics, its success as a mechanism for distributed information integration, and the potential sustainability and reuse benefits of emerging efforts to make the platform components themselves open source. We describe our experience transitioning a large closed-source software system to a community driven, open source project at the Apache Software Foundation, and point to lessons learned that will guide our present efforts to promote the reuse of the EDRN informatics infrastructure by a broader community.

  4. Detecting Large-Scale Brain Networks Using EEG: Impact of Electrode Density, Head Modeling and Source Localization

    Liu, Quanying; Ganzetti, Marco; Wenderoth, Nicole; Mantini, Dante

    2018-01-01

    Resting state networks (RSNs) in the human brain were recently detected using high-density electroencephalography (hdEEG). This was done by using an advanced analysis workflow to estimate neural signals in the cortex and to assess functional connectivity (FC) between distant cortical regions. FC analyses were conducted either using temporal (tICA) or spatial independent component analysis (sICA). Notably, EEG-RSNs obtained with sICA were very similar to RSNs retrieved with sICA from functional magnetic resonance imaging data. It still remains to be clarified, however, what technological aspects of hdEEG acquisition and analysis primarily influence this correspondence. Here we examined to what extent the detection of EEG-RSN maps by sICA depends on the electrode density, the accuracy of the head model, and the source localization algorithm employed. Our analyses revealed that the collection of EEG data using a high-density montage is crucial for RSN detection by sICA, but also the use of appropriate methods for head modeling and source localization have a substantial effect on RSN reconstruction. Overall, our results confirm the potential of hdEEG for mapping the functional architecture of the human brain, and highlight at the same time the interplay between acquisition technology and innovative solutions in data analysis. PMID:29551969

  5. What Are “X-shaped” Radio Sources Telling Us? II. Properties of a Sample of 87

    Saripalli, Lakshmi; Roberts, David H.

    2018-01-01

    In an earlier paper, we presented Jansky Very Large Array multi-frequency, multi-array continuum imaging of a unique sample of low-axial ratio radio galaxies. In this paper, the second in the series, we examine the images to learn the phenomenology of how the off-axis emission relates to the main radio source. Inversion-symmetric offset emission appears to be bimodal and to originate from one of two strategic locations: outer ends of radio lobes (outer-deviation) or from inner ends (inner-deviation). The latter sources are almost always associated with edge-brightened sources. With S- and Z-shaped sources being a subset of outer-deviation sources, this class lends itself naturally to explanations involving black hole axis precession. Our data allow us to present a plausible model for the more enigmatic inner-deviation sources with impressive wings; as for outer-deviation sources these too require black hole axis shifts, although they also require plasma backflows into relic channels. Evolution in morphology over time relates the variety in structures in inner-deviation sources including XRGs. With features such as non-collinearities, central inner-S “spine,” corresponding lobe emission peaks, double and protruding hotspots not uncommon, black hole axis precession, drifts, or flips could be active in a significant fraction of radio sources with prominent off-axis emission. At least 4% of radio galaxies appear to undergo black hole axis rotation. Quasars offer a key signature for recognizing rotating axes. With a rich haul of sources that have likely undergone axis rotation, our work shows the usefulness of low-axial ratio sources in pursuing searches for binary supermassive black holes.

  6. Novel human-associated Lachnospiraceae genetic markers improve detection of fecal pollution sources in urban waters.

    Feng, Shuchen; Bootsma, Melinda; McLellan, Sandra L

    2018-05-04

    The human microbiome contains many organisms that could potentially be used as indicators of human fecal pollution. Here we report the development of two novel human-associated genetic marker assays that target organisms within the family Lachnospiraceae Next-generation sequencing of the V6 region of the 16S rRNA gene from sewage and animal stool samples identified 40 human-associated marker candidates with a robust signal in sewage and low or no occurrence in nonhuman hosts. Two were chosen for quantitative PCR (qPCR) assay development using longer sequences (V2 to V9 regions) generated from clone libraries. Validation of these assays, designated Lachno3 and Lachno12, was performed using fecal samples (n=55) from cat, dog, pig, cow, deer, and gull sources, and compared with established host-associated assays (Lachno2, and two Human Bacteroides assays; HB and HF183/BacR287). Each of the established assays cross-reacted with at least one other animal, including animals common in urban areas. Lachno3 and Lachno12 were primarily human-associated; however, Lachno12 demonstrated low levels of cross-reactivity with select cows, and non-specific amplification in pigs. This limitation may not be problematic when testing urban waters. These novel markers resolved ambiguous results from previous investigations in stormwater-impacted waters, demonstrating their utility. The complexity of the microbiome in humans and animals suggests no single organism is strictly specific to humans, and multiple complementary markers used in combination will provide the highest resolution and specificity for assessing fecal pollution sources. IMPORTANCE Traditional fecal indicator bacteria do not distinguish animal from human fecal pollution, which is necessary to evaluate health risks and mitigate pollution sources. Assessing urban areas is challenging since water can be impacted by sewage, which has a high likelihood of carrying human pathogens, as well as pet waste and urban wildlife. We

  7. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study

  8. Highly sensitive amperometric sensor for micromolar detection of trichloroacetic acid based on multiwalled carbon nanotubes and Fe(II)–phtalocyanine modified glassy carbon electrode

    Kurd, Masoumeh [Department of Chemistry, University of Kurdistan, P. O. Box 416, Sanandaj (Iran, Islamic Republic of); Salimi, Abdollah, E-mail: absalimi@uok.ac.ir [Department of Chemistry, University of Kurdistan, P. O. Box 416, Sanandaj (Iran, Islamic Republic of); Research Center for Nanotechnology, University of Kurdistan, P. O. Box 416, Sanandaj (Iran, Islamic Republic of); Hallaj, Rahman [Department of Chemistry, University of Kurdistan, P. O. Box 416, Sanandaj (Iran, Islamic Republic of)

    2013-04-01

    A highly sensitive electrochemical sensor for the detection of trichloroacetic acid (TCA) is developed by subsequent immobilization of phthalocyanine (Pc) and Fe(II) onto multiwalled carbon nanotubes (MWCNTs) modified glassy carbon (GC) electrode. The GC/MWCNTs/Pc/Fe(II) electrode showed a pair of well-defined and nearly reversible redox couple correspondent to (Fe(III)Pc/Fe(II)Pc) with surface-confined characteristics. The surface coverage (Γ) and heterogeneous electron transfer rate constant (k{sub s}) of immobilized Fe(II)–Pc were calculated as 1.26 × 10{sup −10} mol cm{sup −2} and 28.13 s{sup −1}, respectively. Excellent electrocatalytic activity of the proposed GC/MWCNTs/Pc/Fe(II) system toward TCA reduction has been indicated and the three consequent irreversible peaks for electroreduction of CCl{sub 3}COOH to CH{sub 3}COOH have been clearly seen. The observed chronoamperometric currents are linearly increased with the concentration of TCA at concentration range up to 20 mM. Detection limit and sensitivity of the modified electrode were 2.0 μM and 0.10 μA μM{sup −1} cm{sup −2}, respectively. The applicability of the sensor for TCA detection in real samples was tested. The obtained results suggest that the proposed system can serve as a promising electrochemical platform for TCA detection. Highlights: ► Phthalocyanine (PC) and Fe(II) immobilized onto MWCNTs modified GC electrode. ► A pair of well-defined redox couple correspondent to (Fe(III)Pc/Fe(II)Pc) observed. ► Modified electrode shows excellent catalytic activity to electroreduction of CCl{sub 3}COOH. ► Amperometry and cyclic voltammetry techniques were used for detection of CCl{sub 3}COOH. ► Detection limit and sensitivity were 2.0 μM and 0.10 μA μM{sup −1} cm{sup −2}, respectively.

  9. Comparison of the accuracy of Hybrid Capture II and polymerase chain reaction in detecting clinically important cervical dysplasia: a systematic review and meta-analysis

    Luu, Hung N; Dahlstrom, Kristina R; Mullen, Patricia Dolan; VonVille, Helena M; Scheurer, Michael E

    2013-01-01

    The effectiveness of screening programs for cervical cancer has benefited from the inclusion of Human papillomavirus (HPV) DNA assays; which assay to choose, however, is not clear based on previous reviews. Our review addressed test accuracy of Hybrid Capture II (HCII) and polymerase chain reaction (PCR) assays based on studies with stronger designs and with more clinically relevant outcomes. We searched OvidMedline, PubMed, and the Cochrane Library for English language studies comparing both tests, published 1985–2012, with cervical dysplasia defined by the Bethesda classification. Meta-analysis provided pooled sensitivity, specificity, and 95% confidence intervals (CIs); meta-regression identified sources of heterogeneity. From 29 reports, we found that the pooled sensitivity and specificity to detect high-grade squamous intraepithelial lesion (HSIL) was higher for HCII than PCR (0.89 [CI: 0.89–0.90] and 0.85 [CI: 0.84–0.86] vs. 0.73 [CI: 0.73–0.74] and 0.62 [CI: 0.62–0.64]). Both assays had higher accuracy to detect cervical dysplasia in Europe than in Asia-Pacific or North America (diagnostic odd ratio – dOR = 4.08 [CI: 1.39–11.91] and 4.56 [CI: 1.86–11.17] for HCII vs. 2.66 [CI: 1.16–6.53] and 3.78 [CI: 1.50–9.51] for PCR) and accuracy to detect HSIL than atypical squamous cells of undetermined significance (ASCUS)/ low-grade squamous intraepithelial lesion (LSIL) (HCII-dOR = 9.04 [CI: 4.12–19.86] and PCR-dOR = 5.60 [CI: 2.87–10.94]). For HCII, using histology as a gold standard results in higher accuracy than using cytology (dOR = 2.87 [CI: 1.31–6.29]). Based on higher test accuracy, our results support the use of HCII in cervical cancer screening programs. The role of HPV type distribution should be explored to determine the worldwide comparability of HPV test accuracy

  10. Radioactive sources and contaminated materials in scrap: monitoring, detection and remedial actions

    Gallini, R.; Berna, V.; Bonora, A.; Santini, M.

    1999-01-01

    The scrap recycling in steel and other metal mills represents one of the most relevant activities in the Province of Brescia (Lombardy, Italy). In our Province more than 20 million tonnes of metal scrap are recycled every year by a melting process. Since 1990, many accidents which took place were caused by the unwanted melting of radioactive sources, that were probably hidden in metal scrap. In 1993, the Italian Government stated directives to monitor metal scrap imported from non-EC countries because of the suspicion of the illegal traffic of radioactive materials. In 1996, a law imposed the control of all metal scrap, regardless of their origins. Since 1993, our staff have controlled thousands of railway wagons and trucks. Approximately a hundred steel mills and foundries of aluminium, cooper, brass, etc. have also been controlled and many samples have been collected (flue dust, slag, finished products). During these controls, contaminated areas have been brought to light in two warehouses (Cs 137), in 6 companies (Cs 137 and Am 241), in two landfills of industrial waste (Cs 137) and in a quarry (Cs 137). Up to now the contaminated areas have been cleaned, except for the last one. About 150 radioactive sources on contaminated materials have been found in metal scrap. We found radioactive sources of Co 60, Ra 226, Ir 192, Kr 85, Am 241, while the contamination of metals was mainly due to Ra 226. The situation described above justifies an accurate control of the amount of scrap to reduce the risk of contamination of the workers in the working areas, in the environment and in the general public. (author)

  11. On the Nature of Off-limb Flare Continuum Sources Detected by SDO /HMI

    Heinzel, P.; Kašparová, J. [Astronomical Institute, Czech Academy of Sciences, 25165 Ondřejov (Czech Republic); Kleint, L.; Krucker, S., E-mail: pheinzel@asu.cas.cz [University of Applied Sciences and Arts Northwestern Switzerland, Bahnhofstrasse 6, 5210 Windisch (Switzerland)

    2017-09-20

    The Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory has provided unique observations of off-limb flare emission. White-light continuum enhancements were detected in the “continuum” channel of the Fe 6173 Å line during the impulsive phase of the observed flares. In this paper we aim to determine which radiation mechanism is responsible for such enhancement being seen above the limb, at chromospheric heights around or below 1000 km. Using a simple analytical approach, we compare two candidate mechanisms, the hydrogen recombination continuum (Paschen) and the Thomson continuum due to scattering of disk radiation on flare electrons. Both mechanisms depend on the electron density, which is typically enhanced during the impulsive phase of a flare as the result of collisional ionization (both thermal and also non-thermal due to electron beams). We conclude that for electron densities higher than 10{sup 12} cm{sup −3}, the Paschen recombination continuum significantly dominates the Thomson scattering continuum and there is some contribution from the hydrogen free–free emission. This is further supported by detailed radiation-hydrodynamical (RHD) simulations of the flare chromosphere heated by the electron beams. We use the RHD code FLARIX to compute the temporal evolution of the flare-heating in a semi-circular loop. The synthesized continuum structure above the limb resembles the off-limb flare structures detected by HMI, namely their height above the limb, as well as the radiation intensity. These results are consistent with recent findings related to hydrogen Balmer continuum enhancements, which were clearly detected in disk flares by the IRIS near-ultraviolet spectrometer.

  12. Design of equipment for the detection of nickel-63 source of the gc-2010 electron capture detector

    Lopez O, A.

    2016-01-01

    It is necessary to design a system that is able to detect the presence of the radioactive source nickel-63, located within the electron capture detector gc- 2010 through the use of Arduino technology, presence sensors and motion This in turn It must be interfaced with a system of tracking and tracing , so collectively be mounted inside the mobile laboratory for research and technological development of systems and equipment for measuring radiation , gases and particles. The program has a structure reading sensors, processing the acquired data and execution of an action if necessary. The system does this by receiving data autonomously, the data is processed and at the end, determines whether the source is in normal operating conditions, if subjected to movements that may cause undesired operation if being handled, or has it has been extracted. (Author)

  13. Search Strategy of Detector Position For Neutron Source Multiplication Method by Using Detected-Neutron Multiplication Factor

    Endo, Tomohiro

    2011-01-01

    In this paper, an alternative definition of a neutron multiplication factor, detected-neutron multiplication factor kdet, is produced for the neutron source multiplication method..(NSM). By using kdet, a search strategy of appropriate detector position for NSM is also proposed. The NSM is one of the practical subcritical measurement techniques, i.e., the NSM does not require any special equipment other than a stationary external neutron source and an ordinary neutron detector. Additionally, the NSM method is based on steady-state analysis, so that this technique is very suitable for quasi real-time measurement. It is noted that the correction factors play important roles in order to accurately estimate subcriticality from the measured neutron count rates. The present paper aims to clarify how to correct the subcriticality measured by the NSM method, the physical meaning of the correction factors, and how to reduce the impact of correction factors by setting a neutron detector at an appropriate detector position

  14. Use of FDG-PET to detect a chronic odontogenic infection as a possible source of the brain abscess.

    Sato, Jun; Kuroshima, Takeshi; Wada, Mayumi; Satoh, Akira; Watanabe, Shiro; Okamoto, Shozo; Shiga, Tohru; Tamaki, Nagara; Kitagawa, Yoshimasa

    2016-05-01

    This study describes the use of (18)F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) to detect a chronic odontogenic infection as the possible origin of a brain abscess (BA). A 74-year-old man with esophageal carcinoma was referred to our department to determine the origin of a BA in his oral cavity. He had no acute odontogenic infections. The BA was drained, and bacteria of the Staphylococcus milleri group were detected. Whole body FDG-PET revealed that the only sites of definite uptake of FDG were the esophageal carcinoma and the left upper maxillary region (SUVmax: 4.5). These findings suggested that the BA may have originated from a chronic periodontal infection. Six teeth with progressive chronic periodontal disease were extracted to remove the possible source of BA. These findings excluded the possibility of direct spread of bacteria from the odontogenic infectious lesion to the intracranial cavity. After extraction, there was no relapse of BA.

  15. Experimental optimisation of a moderated sup 2 sup 5 sup 2 Cf source for land mine detection

    Zuin, L; Fabris, D; Lunardon, M; Nebbia, G; Viesti, G; Cinausero, M; Fioretto, E; Prete, G; Palomba, M; Pantaleo, A

    2000-01-01

    A moderated sup 2 sup 5 sup 2 Cf source to be used for the detection of buried land mines has been experimentally characterised. The moderating structure was obtained by using an inner sphere of Pb embedded in a high-density polyethylene (HDPe) brick assembly. The number of capture events in a Cd sample placed outside the structure was used, by varying the dimensions of the brick assembly, to determine the best moderator geometry. Furthermore, the detection of land mines by neutron capture reaction on nitrogen nuclei contained in the explosive was simulated by in field measurements placing the Cd sample at different depths in the soil. The obtained results are compared with predictions from Monte Carlo calculations.

  16. Tianma 65-m telescope detection of new OH maser features towards the water fountain source IRAS 18286-0959

    Chen, Xi; Shen, Zhi-Qiang; Li, Xiao-Qiong; Yang, Kai; Nakashima, Jun-ichi; Wu, Ya-Jun; Zhao, Rong-Bin; Li, Juan; Wang, Jun-Zhi; Jiang, Dong-Rong; Wang, Jin-Qing; Li, Bin; Zhong, Wei-Ye; Yung, Bosco H. K.

    2017-07-01

    We report the results of the OH maser observation towards the water fountain source IRAS 18286-0959 using the newly built Shanghai Tianma 65-m Radio Telescope. We observed the three OH ground state transition lines at frequencies of 1612, 1665 and 1667 MHz. Comparing with the spectra of previous observations, we find new maser spectral components at velocity channels largely shifted from the systemic velocity: the velocity offsets of the newly found components lie in the range 20-40 km s-1 with respect to the systemic velocity. Besides maser variability, another possible interpretation for the newly detected maser features is that part of the molecular gas in the circumstellar envelope is accelerated. The acceleration is probably caused by the passage of a high-velocity molecular jet, which has been detected in previous Very Long Baseline Interferometry observations in the H2O maser line.

  17. Flash sourcing, or rapid detection and characterization of earthquake effects through website traffic analysis

    Laurent Frobert

    2011-06-01

    Full Text Available

    This study presents the latest developments of an approach called ‘flash sourcing’, which provides information on the effects of an earthquake within minutes of its occurrence. Information is derived from an analysis of the website traffic surges of the European–Mediterranean Seismological Centre website after felt earthquakes. These surges are caused by eyewitnesses to a felt earthquake, who are the first who are informed of, and hence the first concerned by, an earthquake occurrence. Flash sourcing maps the felt area, and at least in some circumstances, the regions affected by severe damage or network disruption. We illustrate how the flash-sourced information improves and speeds up the delivery of public earthquake information, and beyond seismology, we consider what it can teach us about public responses when experiencing an earthquake. Future developments should improve the description of the earthquake effects and potentially contribute to the improvement of the efficiency of earthquake responses by filling the information gap after the occurrence of an earthquake.

  18. Open-source algorithm for detecting sea ice surface features in high-resolution optical imagery

    N. C. Wright

    2018-04-01

    Full Text Available Snow, ice, and melt ponds cover the surface of the Arctic Ocean in fractions that change throughout the seasons. These surfaces control albedo and exert tremendous influence over the energy balance in the Arctic. Increasingly available meter- to decimeter-scale resolution optical imagery captures the evolution of the ice and ocean surface state visually, but methods for quantifying coverage of key surface types from raw imagery are not yet well established. Here we present an open-source system designed to provide a standardized, automated, and reproducible technique for processing optical imagery of sea ice. The method classifies surface coverage into three main categories: snow and bare ice, melt ponds and submerged ice, and open water. The method is demonstrated on imagery from four sensor platforms and on imagery spanning from spring thaw to fall freeze-up. Tests show the classification accuracy of this method typically exceeds 96 %. To facilitate scientific use, we evaluate the minimum observation area required for reporting a representative sample of surface coverage. We provide an open-source distribution of this algorithm and associated training datasets and suggest the community consider this a step towards standardizing optical sea ice imagery processing. We hope to encourage future collaborative efforts to improve the code base and to analyze large datasets of optical sea ice imagery.

  19. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  20. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution.

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-25

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO 4 ). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO 4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  1. Open-source algorithm for detecting sea ice surface features in high-resolution optical imagery

    Wright, Nicholas C.; Polashenski, Chris M.

    2018-04-01

    Snow, ice, and melt ponds cover the surface of the Arctic Ocean in fractions that change throughout the seasons. These surfaces control albedo and exert tremendous influence over the energy balance in the Arctic. Increasingly available meter- to decimeter-scale resolution optical imagery captures the evolution of the ice and ocean surface state visually, but methods for quantifying coverage of key surface types from raw imagery are not yet well established. Here we present an open-source system designed to provide a standardized, automated, and reproducible technique for processing optical imagery of sea ice. The method classifies surface coverage into three main categories: snow and bare ice, melt ponds and submerged ice, and open water. The method is demonstrated on imagery from four sensor platforms and on imagery spanning from spring thaw to fall freeze-up. Tests show the classification accuracy of this method typically exceeds 96 %. To facilitate scientific use, we evaluate the minimum observation area required for reporting a representative sample of surface coverage. We provide an open-source distribution of this algorithm and associated training datasets and suggest the community consider this a step towards standardizing optical sea ice imagery processing. We hope to encourage future collaborative efforts to improve the code base and to analyze large datasets of optical sea ice imagery.

  2. Detection of Traveling Ionospheric Disturbances (TIDs) from various man-made sources using Global Navigation Satellite System (GNSS)

    Helmboldt, J.; Park, J.; von Frese, R. R. B.; Grejner-Brzezinska, D. A.

    2016-12-01

    Traveling ionospheric disturbance (TID) is generated by various sources and detectable by observing the spatial and temporal change of electron contents in the ionosphere. This study focused on detecting and analyzing TIDs generated by acoustic-gravity waves from man-made events including underground nuclear explosions (UNEs), mine collapses, mine blasts, and large chemical explosions (LCEs) using Global Navigation Satellite System (GNSS). In this study we selected different types of events for case study which covers two US and three North Korean UNEs, two large US mine collapses, three large US mine blasts, and a LCE in northern China and a second LCE at the Nevada Test Site. In most cases, we successfully detected the TIDs as array signatures from the multiple nearby GNSS stations. The array-based TID signatures from these studies were found to yield event-appropriate TID propagation speeds ranging from about a few hundred m/s to roughly a km/s. In addition, the event TID waveforms, and propagation angles and directions were established. The TID waveforms and the maximum angle between each event and the IPP of its TID with the longest travel distance from the source may help differentiate UNEs and LCEs, but the uneven distributions of the observing GNSS stations complicates these results. Thus, further analysis is required of the utility of the apertures of event signatures in the ionosphere for discriminating these events. In general, the results of this study show the potential utility of GNSS observations for detecting and mapping the ionospheric signatures of large-energy anthropological explosions and subsurface collapses.

  3. From chemolithoautotrophs to electrolithoautotrophs: CO2 fixation by Fe(II)-oxidizing bacteria coupled with direct uptake of electrons from solid electron sources.

    Ishii, Takumi; Kawaichi, Satoshi; Nakagawa, Hirotaka; Hashimoto, Kazuhito; Nakamura, Ryuhei

    2015-01-01

    At deep-sea vent systems, hydrothermal emissions rich in reductive chemicals replace solar energy as fuels to support microbial carbon assimilation. Until recently, all the microbial components at vent systems have been assumed to be fostered by the primary production of chemolithoautotrophs; however, both the laboratory and on-site studies demonstrated electrical current generation at vent systems and have suggested that a portion of microbial carbon assimilation is stimulated by the direct uptake of electrons from electrically conductive minerals. Here we show that chemolithoautotrophic Fe(II)-oxidizing bacterium, Acidithiobacillus ferrooxidans, switches the electron source for carbon assimilation from diffusible Fe(2+) ions to an electrode under the condition that electrical current is the only source of energy and electrons. Site-specific marking of a cytochrome aa3 complex (aa3 complex) and a cytochrome bc1 complex (bc1 complex) in viable cells demonstrated that the electrons taken directly from an electrode are used for O2 reduction via a down-hill pathway, which generates proton motive force that is used for pushing the electrons to NAD(+) through a bc1 complex. Activation of carbon dioxide fixation by a direct electron uptake was also confirmed by the clear potential dependency of cell growth. These results reveal a previously unknown bioenergetic versatility of Fe(II)-oxidizing bacteria to use solid electron sources and will help with understanding carbon assimilation of microbial components living in electronically conductive chimney habitats.

  4. A novel aggregation induced emission active cyclometalated Ir(III) complex as a luminescent probe for detection of copper(II) ion in aqueous solution

    Shen, Wei; Yan, Liqiang; Tian, Wenwen; Cui, Xia; Qi, Zhengjian, E-mail: qizhengjian@seu.edu.cn; Sun, Yueming, E-mail: sun@seu.edu.cn

    2016-09-15

    We report the synthesis and characterization of a novel aggregation induced emission (AIE) active cyclometalated Ir(III) complex, namely [Ir(dfppy){sub 2}(phen-DPA)]PF{sub 6}, where dfppy and phen-DPA represent 2-(2,4-difluorophenyl)pyridine and 2-(bis(pyridin-2-ylmethyl)amino)-N-(1,10-phenanthrolin-5-yl)acetamide, respectively. The complex showed remarkable selectivity for copper(II) in aqueous solution over other competitive ions. Furthermore, this sensor showed a rapid and reversible response to copper(II) in aqueous solution with a detection limit of 65 nM.

  5. Sensitive and selective detection of Cu(II) ion: A new effective 1,8-naphthalimide-based fluorescence 'turn off' sensor.

    Huang, Guozhen; Li, Chuang; Han, Xintong; Aderinto, Stephen Opeyemi; Shen, Kesheng; Mao, Shanshan; Wu, Huilu

    2018-06-01

    The present study reports the development of a new 1,8-naphthalimide-based fluorescent sensor V for monitoring Cu(II) ions. The sensor exhibited pH independence over a wide pH range 2.52-9.58, and indicated its possible use for monitoring Cu(II) ions in a competitive pH medium. The sensor also showed high selectivity and sensitivity towards the Cu(II) ions over other competitive metal ions in DMSO-HEPES buffer (v/v, 1:1; pH 7.4) with a fluorescence 'turn off' mode of 79.79% observed. A Job plot indicated the formation of a 1:1 binding mode of the sensor with Cu(II) ions. The association constant and detection limit were 1.14 × 10 6  M -1 and 4.67 × 10 -8 M, respectively. The fluorescence spectrum of the sensor was quenched due to the powerful paramagnetic nature of the Cu(II) ions. Potential application of this sensor was also demonstrated when determining Cu(II) ion levels in two different water samples. Copyright © 2018 John Wiley & Sons, Ltd.

  6. Simple and green synthesis of piperazine-grafted reduced graphene oxide and its application for the detection of Hg(II)

    Zuo, Yinxiu; Xu, Jingkun; Xing, Huakun; Duan, Xuemin; Lu, Limin; Ye, Guo; Jia, Haiyan; Yu, Yongfang

    2018-04-01

    In this paper, piperazine-grafted reduced graphene oxide (NH-rGO) was synthesized via a simple and green two-step procedure: (i) opening of the resulting epoxides of graphene oxide (GO) with piperazine (NH) through nucleophilic substitution; (ii) reduction of GO with ascorbic acid. Its structure and morphology were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy. The NH-rGO modified glassy carbon electrode was explored as an electrochemical sensor for the determination of Hg(II) using a differential pulse anodic stripping voltammetry technique. Hg(II) can be efficiently accumulated and deposited on the surface of a modified electrode by strong coordination chemical bonds formed between Hg(II) and NH. And then the anodic stripping current can be significantly enhanced by rGO with the merits of large specific surface area and high conductivity, which served as a signal amplifier, finally realizing the highly sensitive determination of Hg(II). The experimental parameters including the pH value of the acetate buffer, deposition potential and deposition time were optimized. Under optimal conditions, the developed sensor exhibited a wide linear range from 0.4-12 000 nM with a low limit of detection of 0.2 nM, which is well below the guideline value in drinking water set by the WHO. Moreover, the practical application of this method was confirmed by an assay of Hg(II) in tap water samples with acceptable results.

  7. Detection of interferon alpha protein reveals differential levels and cellular sources in disease.

    Rodero, Mathieu P; Decalf, Jérémie; Bondet, Vincent; Hunt, David; Rice, Gillian I; Werneke, Scott; McGlasson, Sarah L; Alyanakian, Marie-Alexandra; Bader-Meunier, Brigitte; Barnerias, Christine; Bellon, Nathalia; Belot, Alexandre; Bodemer, Christine; Briggs, Tracy A; Desguerre, Isabelle; Frémond, Marie-Louise; Hully, Marie; van den Maagdenberg, Arn M J M; Melki, Isabelle; Meyts, Isabelle; Musset, Lucile; Pelzer, Nadine; Quartier, Pierre; Terwindt, Gisela M; Wardlaw, Joanna; Wiseman, Stewart; Rieux-Laucat, Frédéric; Rose, Yoann; Neven, Bénédicte; Hertel, Christina; Hayday, Adrian; Albert, Matthew L; Rozenberg, Flore; Crow, Yanick J; Duffy, Darragh

    2017-05-01

    Type I interferons (IFNs) are essential mediators of antiviral responses. These cytokines have been implicated in the pathogenesis of autoimmunity, most notably systemic lupus erythematosus (SLE), diabetes mellitus, and dermatomyositis, as well as monogenic type I interferonopathies. Despite a fundamental role in health and disease, the direct quantification of type I IFNs has been challenging. Using single-molecule array (Simoa) digital ELISA technology, we recorded attomolar concentrations of IFNα in healthy donors, viral infection, and complex and monogenic interferonopathies. IFNα protein correlated well with functional activity and IFN-stimulated gene expression. High circulating IFNα levels were associated with increased clinical severity in SLE patients, and a study of the cellular source of IFNα protein indicated disease-specific mechanisms. Measurement of IFNα attomolar concentrations by digital ELISA will enhance our understanding of IFN biology and potentially improve the diagnosis and stratification of pathologies associated with IFN dysregulation. © 2017 Rodero et al.

  8. Detection of a very bright source close to the LMC supernova SN 1987A

    Nisenson, P.; Papaliolios, C.; Karovska, M.; Noyes, R.

    1987-01-01

    High angular resolution observations of the supernova in the Large Magellanic Cloud, SN 1987A, have revealed a bright source separated from the SN by approximately 60 mas with a magnitude difference of 2.7 at 656 nm (H-alpha). Speckle imaging techniques were applied to data recorded with the CfA two-dimensional photon counting detector on the CTIO 4 m telescope on March 25 and April 2 to allow measurements in H-alpha on both nights and at 533 nm and 450 nm on the second night. The nature of this object is as yet unknown, though it is almost certainly a phenomenon related to the SN.

  9. Multichannel deconvolution and source detection using sparse representations: application to Fermi project

    Schmitt, Jeremy

    2011-01-01

    This thesis presents new methods for spherical Poisson data analysis for the Fermi mission. Fermi main scientific objectives, the study of diffuse galactic background et the building of the source catalog, are complicated by the weakness of photon flux and the point spread function of the instrument. This thesis proposes a new multi-scale representation for Poisson data on the sphere, the Multi-Scale Variance Stabilizing Transform on the Sphere (MS-VSTS), consisting in the combination of a spherical multi-scale transform (wavelets, curvelets) with a variance stabilizing transform (VST). This method is applied to mono- and multichannel Poisson noise removal, missing data interpolation, background extraction and multichannel deconvolution. Finally, this thesis deals with the problem of component separation using sparse representations (template fitting). (author) [fr

  10. Radial Photonic Crystal for detection of frequency and position of radiation sources.

    Carbonell, J; Díaz-Rubio, A; Torrent, D; Cervera, F; Kirleis, M A; Piqué, A; Sánchez-Dehesa, J

    2012-01-01

    Based on the concepts of artificially microstructured materials, i.e. metamaterials, we present here the first practical realization of a radial wave crystal. This type of device was introduced as a theoretical proposal in the field of acoustics, and can be briefly defined as a structured medium with radial symmetry, where the constitutive parameters are invariant under radial geometrical translations. Our practical demonstration is realized in the electromagnetic microwave spectrum, because of the equivalence between the wave problems in both fields. A device has been designed, fabricated and experimentally characterized. It is able to perform beam shaping of punctual wave sources, and also to sense position and frequency of external radiators. Owing to the flexibility offered by the design concept, other possible applications are discussed.

  11. Detection of new southern SiO maser sources associated with Mira and symbiotic stars

    Allen, D.A.; Hall, P.J.; Norris, R.P.; Troup, E.R.; Wark, R.M.; Wright, A.E.

    1989-01-01

    In 1987 July the Parkes radio telescope was used to search for 43.12 GHz SiO maser emission from southern late-type stars. We report the discovery of such emission from 12 Mira-like systems, including the symbiotic star H1-36, and discuss the implications of our data for the symbiotic stars. We identify several M-type Mira variables with unusually low SiO/infrared flux ratios, but with present data are not able to discredit the correlation between the two parameters. In addition, we present line profiles for the only other known symbiotic maser, R Aqr, at unprecedented signal-to-noise ratio; these profiles show linearly polarized emission from several components of the source. (author)

  12. Metamaterials-based sensor to detect and locate nonlinear elastic sources

    Gliozzi, Antonio S.; Scalerandi, Marco [Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Miniaci, Marco; Bosia, Federico [Department of Physics, University of Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Pugno, Nicola M. [Laboratory of Bio-Inspired and Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123 Trento (Italy); Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo (Trento) (Italy); School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom)

    2015-10-19

    In recent years, acoustic metamaterials have attracted increasing scientific interest for very diverse technological applications ranging from sound abatement to ultrasonic imaging, mainly due to their ability to act as band-stop filters. At the same time, the concept of chaotic cavities has been recently proposed as an efficient tool to enhance the quality of nonlinear signal analysis, particularly in the ultrasonic/acoustic case. The goal of the present paper is to merge the two concepts in order to propose a metamaterial-based device that can be used as a natural and selective linear filter for the detection of signals resulting from the propagation of elastic waves in nonlinear materials, e.g., in the presence of damage, and as a detector for the damage itself in time reversal experiments. Numerical simulations demonstrate the feasibility of the approach and the potential of the device in providing improved signal-to-noise ratios and enhanced focusing on the defect locations.

  13. Metamaterials-based sensor to detect and locate nonlinear elastic sources

    Gliozzi, Antonio S.; Scalerandi, Marco; Miniaci, Marco; Bosia, Federico; Pugno, Nicola M.

    2015-01-01

    In recent years, acoustic metamaterials have attracted increasing scientific interest for very diverse technological applications ranging from sound abatement to ultrasonic imaging, mainly due to their ability to act as band-stop filters. At the same time, the concept of chaotic cavities has been recently proposed as an efficient tool to enhance the quality of nonlinear signal analysis, particularly in the ultrasonic/acoustic case. The goal of the present paper is to merge the two concepts in order to propose a metamaterial-based device that can be used as a natural and selective linear filter for the detection of signals resulting from the propagation of elastic waves in nonlinear materials, e.g., in the presence of damage, and as a detector for the damage itself in time reversal experiments. Numerical simulations demonstrate the feasibility of the approach and the potential of the device in providing improved signal-to-noise ratios and enhanced focusing on the defect locations

  14. High-power, photofission-inducing bremsstrahlung source for intense pulsed active detection of fissile material

    J. C. Zier

    2014-06-01

    Full Text Available Intense pulsed active detection (IPAD is a promising technique for detecting fissile material to prevent the proliferation of special nuclear materials. With IPAD, fissions are induced in a brief, intense radiation burst and the resulting gamma ray or neutron signals are acquired during a short period of elevated signal-to-noise ratio. The 8 MV, 200 kA Mercury pulsed-power generator at the Naval Research Laboratory coupled to a high-power vacuum diode produces an intense 30 ns bremsstrahlung beam to study this approach. The work presented here reports on Mercury experiments designed to maximize the photofission yield in a depleted-uranium (DU object in the bremsstrahlung far field by varying the anode-cathode (AK diode gap spacing and by adding an inner-diameter-reducing insert in the outer conductor wall. An extensive suite of diagnostics was fielded to measure the bremsstrahlung beam and DU fission yield as functions of diode geometry. Delayed fission neutrons from the DU proved to be a valuable diagnostic for measuring bremsstrahlung photons above 5 MeV. The measurements are in broad agreement with particle-in-cell and Monte Carlo simulations of electron dynamics and radiation transport. These show that with increasing AK gap, electron losses to the insert and outer conductor wall increase and that the electron angles impacting the bremsstrahlung converter approach normal incidence. The diode conditions for maximum fission yield occur when the gap is large enough to produce electron angles close to normal, yet small enough to limit electron losses.

  15. High-power, photofission-inducing bremsstrahlung source for intense pulsed active detection of fissile material

    Zier, J. C.; Mosher, D.; Allen, R. J.; Commisso, R. J.; Cooperstein, G.; Hinshelwood, D. D.; Jackson, S. L.; Murphy, D. P.; Ottinger, P. F.; Richardson, A. S.; Schumer, J. W.; Swanekamp, S. B.; Weber, B. V.

    2014-06-01

    Intense pulsed active detection (IPAD) is a promising technique for detecting fissile material to prevent the proliferation of special nuclear materials. With IPAD, fissions are induced in a brief, intense radiation burst and the resulting gamma ray or neutron signals are acquired during a short period of elevated signal-to-noise ratio. The 8 MV, 200 kA Mercury pulsed-power generator at the Naval Research Laboratory coupled to a high-power vacuum diode produces an intense 30 ns bremsstrahlung beam to study this approach. The work presented here reports on Mercury experiments designed to maximize the photofission yield in a depleted-uranium (DU) object in the bremsstrahlung far field by varying the anode-cathode (AK) diode gap spacing and by adding an inner-diameter-reducing insert in the outer conductor wall. An extensive suite of diagnostics was fielded to measure the bremsstrahlung beam and DU fission yield as functions of diode geometry. Delayed fission neutrons from the DU proved to be a valuable diagnostic for measuring bremsstrahlung photons above 5 MeV. The measurements are in broad agreement with particle-in-cell and Monte Carlo simulations of electron dynamics and radiation transport. These show that with increasing AK gap, electron losses to the insert and outer conductor wall increase and that the electron angles impacting the bremsstrahlung converter approach normal incidence. The diode conditions for maximum fission yield occur when the gap is large enough to produce electron angles close to normal, yet small enough to limit electron losses.

  16. A novel method of adrenaline concentration detection using fiber optical biosensor based on the catalysis of iron(II) phthalocyanine

    Zhou, Xuan; Huang, Jun; Li, Mingtian; Wang, Bin

    2008-12-01

    As an effective alternative to the nature enzyme, metallophthalocyanine (MPc), having the advantages of easy accessibility, good stability and low cost, are used as catalyzer for the adrenaline (AD) oxidation. In this paper, the oxidation of AD by dioxygen using iron(II) phthalocyanine (FePc) as the catalyst was studied by electronic absorption spectra. The experimental results indicate that the oxidation product of AD catalyzed by FePc is adrenochrome with characteristic peaks at 298 nm and 267 nm. The catalytic activities of FePc are evaluated by the ratios of the absorbance at 298 nm of adrenochrome. The optimal concentration, pH and temperature for the oxidation of AD are 5.0×10-5 M, 8.0 and 55 oC, respectively. By using lock-in technology, the fiber optic adrenaline biosensor based on FePc catalysis and fluorescence quenching was fabricated and studied. A linear relationship between φ, the phase delay of the sensor head, and AD concentration was observed in the range of 2.0×10-6 to 9.0×10-6 M and 2.0×10-5 to 9.0×10-5 M. The standard deviation (SD) values are 4.7×10-8 (n = 5) and 5.9×10-7 (n = 5) M, respectively, while the detection limit is 4.0×10-7 M. The biosensor has the response time of about 15 min and the preferred reproducibility and stability.

  17. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    Zhang Nan; Hu Bin

    2012-01-01

    Graphical abstract: Ion imprinted 3-mercaptopropyltrimethoxysilane (MPTS) coated stir bar for selective extraction of trace Cd(II). Highlights: ► Ion imprinted polymers were proposed as the coating for SBSE for the first time. ► Cd(II) imprinted MPTS-silica coating was prepared by a double-imprinting concept. ► A novel method of SBSE–ICP-MS was developed for the determination of Cd in waters. ► This method is rapid, selective, sensitive and applicable for determining trace Cd(II) in waters. - Abstract: Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar −1 . The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L −1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L −1 , n = 7). The proposed method was successfully applied for the

  18. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    Zhang Nan [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin, E-mail: binhu@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2012-04-20

    Graphical abstract: Ion imprinted 3-mercaptopropyltrimethoxysilane (MPTS) coated stir bar for selective extraction of trace Cd(II). Highlights: Black-Right-Pointing-Pointer Ion imprinted polymers were proposed as the coating for SBSE for the first time. Black-Right-Pointing-Pointer Cd(II) imprinted MPTS-silica coating was prepared by a double-imprinting concept. Black-Right-Pointing-Pointer A novel method of SBSE-ICP-MS was developed for the determination of Cd in waters. Black-Right-Pointing-Pointer This method is rapid, selective, sensitive and applicable for determining trace Cd(II) in waters. - Abstract: Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol-gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 {mu}g and 0.8 {mu}g bar{sup -1}. The detection limit (3{sigma}) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L{sup -1} and the relative standard

  19. Molecular detection of genotype II grass carp reovirus based on nucleic acid sequence-based amplification combined with enzyme-linked immunosorbent assay (NASBA-ELISA).

    Zeng, Weiwei; Yao, Wei; Wang, Yingying; Li, Yingying; Bermann, Sven M; Ren, Yan; Shi, Cunbin; Song, Xinjian; Huang, Qiwen; Zheng, Shuchen; Wang, Qing

    2017-05-01

    Grass carp reovirus (GCRV) is the causative agent of the grass carp hemorrhagic disease that has resulted in severe economic losses in the grass carp (Ctenopharyngodon idella) farming industry in China. Early diagnosis and vaccine administration are important priorities for GCRV control. In this study, a nucleic acid sequence-based amplification with enzyme-linked immunosorbent assay (NASBA-ELISA) was developed for to detect genotype II GCRV (GCRV- II). Primers specifically targeting viral RNA genome segment 6 were utilized for amplification in an isothermal digoxigenin-labeling NASBA process, resulting in DIG-labeled RNA amplicons. The amplicons were hybridized to specific biotinylated DNA probes and the products were detected colorimetrically using horseradish peroxidase and a microplate reader. The new method is able to detect GCRV at 14 copies/μL within 5h and had a diagnostic sensitivity and a specificity of 100% when GCRV-II and non-target virus were tested. This NASBA-ELISA was evaluated using a panel of clinical samples (n=103) to demonstrate that it is a rapid, effective and sensitive method for GCRV detection in grass carp aquaculture. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings

    Vullings, R; Bergmans, J W M; Peters, C H L; Hermans, M J M; Wijn, P F F; Oei, S G

    2010-01-01

    The use of the non-invasively obtained fetal electrocardiogram (ECG) in fetal monitoring is complicated by the low signal-to-noise ratio (SNR) of ECG signals. Even after removal of the predominant interference (i.e. the maternal ECG), the SNR is generally too low for medical diagnostics, and hence additional signal processing is still required. To this end, several methods for exploiting the spatial correlation of multi-channel fetal ECG recordings from the maternal abdomen have been proposed in the literature, of which principal component analysis (PCA) and independent component analysis (ICA) are the most prominent. Both PCA and ICA, however, suffer from the drawback that they are blind source separation (BSS) techniques and as such suboptimum in that they do not consider a priori knowledge on the abdominal electrode configuration and fetal heart activity. In this paper we propose a source separation technique that is based on the physiology of the fetal heart and on the knowledge of the electrode configuration. This technique operates by calculating the spatial fetal vectorcardiogram (VCG) and approximating the VCG for several overlayed heartbeats by an ellipse. By subsequently projecting the VCG onto the long axis of this ellipse, a source signal of the fetal ECG can be obtained. To evaluate the developed technique, its performance is compared to that of both PCA and ICA and to that of augmented versions of these techniques (aPCA and aICA; PCA and ICA applied on preprocessed signals) in generating a fetal ECG source signal with enhanced SNR that can be used to detect fetal QRS complexes. The evaluation shows that the developed source separation technique performs slightly better than aPCA and aICA and outperforms PCA and ICA and has the main advantage that, with respect to aPCA/PCA and aICA/ICA, it performs more robustly. This advantage renders it favorable for employment in automated, real-time fetal monitoring applications

  1. Energy based source location by using acoustic emission for damage detection in steel and composite CNG tank

    Kim, Il Sik; Han, Byeong Hee; Park, Choon Su; Yoon, Dong Jin [Center for Safety Measurements, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2015-10-15

    Acoustic emission (AE) is an effective nondestructive test that uses transient elastic wave generated by the rapid release of energy within a material to detect any further growth or expansion of existing defects. Over the past decades, because of environmental issues, the use of compressed natural gas (CNG) as an alternative fuel for vehicles is increasing because of environmental issues. For this reason, the importance and necessity of detecting defects on a CNG fuel tank has also come to the fore. The conventional AE method used for source location is highly affected by the wave speed on the structure, and this creates problems in inspecting a composite CNG fuel tank. Because the speed and dispersion characteristics of the wave are different according to direction of structure and laminated layers. In this study, both the conventional AE method and the energy based contour map method were used for source location. This new method based on pre-acquired D/B was used for overcoming the limitation of damage localization in a composite CNG fuel tank specimen which consists of a steel liner cylinder overwrapped by GFRP. From the experimental results, it is observed that the damage localization is determined with a small error at all tested points by using the energy based contour map method, while there were a number of mis-locations or large errors at many tested points by using the conventional AE method. Therefore, the energy based contour map method used in this work is more suitable technology for inspecting composite structures.

  2. Marine controlled source electromagnetic (mCSEM) detects hydrocarbon reservoirs in the Santos Basin - Brazil

    Buonora, Marco Polo Pereira; Rodrigues, Luiz Felipe [PETROBRAS, Rio de Janeiro, RJ (Brazil); Zerilli, Andrea; Labruzzo, Tiziano [WesternGeco, Houston, TX (United States)

    2008-07-01

    In recent years marine Controlled Source Electromagnetic (mCSEM) has driven the attention of an increasing number of operators due to its sensitivity to map resistive structures, such as hydrocarbon reservoirs beneath the ocean floor and successful case histories have been reported. The Santos basin mCSEM survey was performed as part of a technical co-operation project between PETROBRAS and Schlumberger to assess the integration of selected deep reading electromagnetic technologies into the full cycle of oil field exploration and development. The survey design was based on an in-depth sensitivity study, built on known reservoirs parameters, such as thickness, lateral extent, overburden and resistivities derived from seismic and well data. In this context, the mCSEM data were acquired to calibrate the technology over the area's known reservoirs, quantify the resistivity anomalies associated with those reservoirs, with the expectation that new prospective locations could be found. We show that the mCSEM response of the known reservoirs yields signatures that can be clearly imaged and accurately quantified and there are evident correlations between the mCSEM anomalies and the reservoirs. (author)

  3. Portable gamma-ray detection system for location of radioactive sources

    Worth, G.M.; Henery, C.N.; Hastings, R.D.; France, S.W.

    1976-01-01

    A portable, battery-powered gamma radiation detection system, the RBM 1100 Road Block Monitor, is described. The detector is a 12.7-cm diameter by 2.54-cm thick NaI(Tl) integral assembly, housed in a weatherproof, insulated case with high and low voltage batteries, amplifier, lower level discriminator, low power CMOS logic electronics, and a VHF FM transmitter. Alarms indicating the presence of radioactive material are generated by a logic system that periodically stores a trip level based on an average background plus an internally calculated standard deviation. The operator may select the optimum counting time, the trip level in numbers of standard deviations above the average background, the background updating mode, and the method of alarm annunciation. Alarms may be indicated locally by panel indication and/or audible tone, or remotely via a VHF FM transmitter with a maximum range of 1.6-km line-of-sight to a suitable receiver. Count rate may be read on a top panel meter or recorded on a chart recorder. A single frame camera may be attached to provide a photographic record. Battery lifetime is 100 to 300 hours, depending on alarm rate and use of the transmitter

  4. Initial study with Tc99m antigranulocyte antibody (MAK-47) in detection sources of infection

    Cwikla, J.B.; Buscombe, J.R.; Hilson, A.J.; Janoki, G.A.

    1997-01-01

    Antigranulocytes antibodies (AGAB) are antibodies directed against glycoprotein on the surface of granulocytes and as such provides in vivo cell labelling. They are easily labelled with Tc99m and comes a one step labelling technique. 20 patients have been studied 1 h and 4-6 hours after administration of 200 MBq of Tc99m AGAB (MAK-47). Less then 0.5 mg of antibody was given to each patients. Sites of uptake and outside of the reticular-endothelial system were reported as showing positive accumulation. Clinical results were confirmed by microbiological, pathological examinations, clinical follow-up and autopsy. There were 8 patients who had sites of infection confirmed by additional examination. All patients were visualized by Tc99m AGAB (MAK-47). There were 4 cases of osteomyelitis and septic arthritis and 4 cases of focal intra-abdominal infection. Two patients had uptake in non-infected/inflammatory arthritis, both in the knee. The remaining patients had true negative studies. The diagnostic accuracy of this study was as follows: sensitivity 100%, specificity 83%, positive predictive value (PPV) was 80% and negative predictive value (NPV) was 100%. Antigranulocyte antibody (MAK-47) seems to by promising tool in detecting focal infection in bone and soft tissue, except physiological accumulation in some parts of the body. It should be considered that antibodies can have non-specific uptake in non-infected, inflammation sites. It is easy to use and no had allergic reaction and HAMA antibody (human antimouse antibody). (author)

  5. II. The intermediate velocity source in the 40Ca+40Ca reaction at Elab=35 AMeV

    Sosin, Z.; Planeta, R.; Ciszek, T.

    2001-01-01

    The shape of the velocity distributions of charged particles projected on the beam direction can be explained if emissions from the hot projectile-like fragment and the target-like fragment are supplemented by an emission from an intermediate velocity source located between them. The creation of this source is predicted by a two-stage reaction model where, in the second stage, some of the nucleons identified in the first stage as participants form a group of clusters located in the region between the colliding nuclei. The cluster coalescence process is governed on the average by the maximum value of entropy, although its fluctuations are also significant. The properties of the intermediate velocity source are precisely described, including the isotopic composition of the emitted particles. (orig.)

  6. Detection of the Diversity of Cytoplasmic Male Sterility Sources in Broccoli (Brassica Oleracea var. Italica) Using Mitochondrial Markers.

    Shu, Jinshuai; Liu, Yumei; Li, Zhansheng; Zhang, Lili; Fang, Zhiyuan; Yang, Limei; Zhuang, Mu; Zhang, Yangyong; Lv, Honghao

    2016-01-01

    Broccoli (Brassica oleracea var. italica) is an important commercial vegetable crop. As part of an efficient pollination system, cytoplasmic male sterility (CMS) has been widely used for broccoli hybrid production. Identifying the original sources of CMS in broccoli accessions has become an important part of broccoli breeding. In this study, the diversity of the CMS sources of 39 broccoli accessions, including 19 CMS lines and 20 hybrids, were analyzed using mitochondrial markers. All CMS accessions contained the ogu orf138-related DNA fragment and the key genes of nap CMS, pol CMS, and tour CMS were not detected. The 39 CMS accessions were divided into five groups using six orf138-related and two simple sequence repeat markers. We observed that ogu CMS R3 constituted 79.49% of the CMS sources. CMS6 and CMS26 were differentiated from the other accessions using a specific primer. CMS32 was distinguished from the other accessions based on a 78-nucleotide deletion at the same locus as the orf138-related sequence. When the coefficient was about 0.90, five CMS accessions (13CMS6, 13CMS23, 13CMS24, 13CMS37, and 13CMS39) exhibiting abnormal floral organs with poor seed setting were grouped together. The polymerase chain reaction amplification profiles for these five accessions differed from those of the other accessions. We identified eight useful molecular markers that can be used to detect CMS types during broccoli breeding. Our data also provide important information relevant to future studies on the possible origins and molecular mechanisms of CMS in broccoli.

  7. Electrochemical sensor based on EDTA intercalated into layered double hydroxides of magnesium and aluminum for ultra trace level detection of lead (II)

    Dong, Junping; Fang, Qinghua; He, Haibo; Xu, Jiaqiang; Zhang, Yuan; Sun, Youbao

    2015-01-01

    The chelator ethylene diaminetetraacetate (EDTA) has been intercalated into layered double hydroxides by the anion exchange method. The resulting composites were characterized by powder X-ray diffraction, FTIR spectroscopy, thermogravimetry and X-ray photoelectron spectrometry. They were applied to modify a carbon paste electrode for the stripping voltammetric determination of lead (II) ions at ng L −1 levels. Stripping currents are linearly related to the logarithm of Pb (II) concentrations from 2 ng L −1 to 33 μg L −1 . The detection limit (3σ) is as low as 0.95 ng L −1 . The method was successfully applied to the determination of Pb (II) in spiked tap water without any pretreatment.(author)

  8. Greenhouse Gas Source Detection and Attribution in the San Francisco Bay Area of California Using a Mobile Measurement Platform

    Martien, P. T.; Guha, A.; Newman, S.; Young, A.; Bower, J.; Perkins, I.; Randall, S.; Stevenson, E.; Hilken, H.

    2017-12-01

    The Bay Area Air Quality Management District, the San Francisco Bay Area's air quality regulatory agency, has set a goal to reduce the region's greenhouse gas (GHG) emissions 80% below 1990 levels by 2050, consistent with the State of California's climate goals. Recently, the Air District's governing board adopted a 2017 Clean Air Plan advancing the agency's vision and including actions to put the region on a path to achieving the 2050 goal while also reducing air pollution and related health impacts. The Plan includes GHG rule-making efforts, policy initiatives, local government partnerships, outreach, grants and incentives, encompassing over 250 specific implementation actions across all economic sectors to effect ambitious emission reductions in the region. To support the 2017 Plan, the Air District has built a mobile measurement platform (GHG research van) to perform targeted CH4 emissions hotspot detection and source attribution. Instruments in the van measure CH4, CO2 and N2O in ambient plumes. Coincident measurements of source tracers like isotopic methane (13C - CH4), CO and ethane (C2H6) provide the capability to distinguish between biogenic, combustion-based and fossil-based fugitive methane sources. We report observations of CH4 plumes from source-specific measurements in and around facilities including a wastewater treatment plant, a composting operation, a waste-to-energy anaerobic digestion plant and a few refineries. We performed leak surveys inside several electric utility-operated facilities including a power plant and an underground natural gas storage facility. We sampled exhaust from a roadway tunnel and computed fleet-averaged automobile-related CH4 and N2O emission factors. We used tracer-to-tracer emission ratios to create chemical signatures of emissions from each sampled source category. We compare measurement-based ratios with those used to derive the regional GHG inventory. Data from these and other sources will lead to an improved

  9. Using a source-receptor approach to characterise VOC behaviour in a French urban area influenced by industrial emissions. Part II: source contribution assessment using the Chemical Mass Balance (CMB) model.

    Badol, Caroline; Locoge, Nadine; Galloo, Jean-Claude

    2008-01-25

    In Part I of this study (Badol C, Locoge N, Leonardis T, Gallo JC. Using a source-receptor approach to characterise VOC behaviour in a French urban area influenced by industrial emissions, Part I: Study area description, data set acquisition and qualitative data analysis of the data set. Sci Total Environ 2007; submitted as companion manuscript.) the study area, acquisition of the one-year data set and qualitative analysis of the data set have been described. In Part II a source profile has been established for each activity present in the study area: 6 profiles (urban heating, solvent use, natural gas leakage, biogenic emissions, gasoline evaporation and vehicle exhaust) have been extracted from literature to characterise urban sources, 7 industrial profiles have been established via canister sampling around industrial plants (hydrocarbon cracking, oil refinery, hydrocarbon storage, lubricant storage, lubricant refinery, surface treatment and metallurgy). The CMB model is briefly described and its implementation is discussed through the selection of source profiles and fitting species. Main results of CMB modellings for the Dunkerque area are presented. (1) The daily evolution of source contributions for the urban wind sector shows that the vehicle exhaust source contribution varies between 40 and 55% and its relative increase at traffic rush hours is hardly perceptible. (2) The relative contribution of vehicle exhaust varies from 55% in winter down to 30% in summer. This decrease is due to the increase of the relative contribution of hydrocarbon storage source reaching up to 20% in summer. (3) The evolution of source contributions with wind directions has confirmed that in urban wind sectors the contribution of vehicle exhaust dominate with around 45-55%. For the other wind sectors that include some industrial plants, the contribution of industrial sources is around 60% and could reach 80% for the sector 280-310 degrees , which corresponds to the most dense

  10. Detection and characterization of lightning-based sources using continuous wavelet transform: application to audio-magnetotellurics

    Larnier, H.; Sailhac, P.; Chambodut, A.

    2018-01-01

    Atmospheric electromagnetic waves created by global lightning activity contain information about electrical processes of the inner and the outer Earth. Large signal-to-noise ratio events are particularly interesting because they convey information about electromagnetic properties along their path. We introduce a new methodology to automatically detect and characterize lightning-based waves using a time-frequency decomposition obtained through the application of continuous wavelet transform. We focus specifically on three types of sources, namely, atmospherics, slow tails and whistlers, that cover the frequency range 10 Hz to 10 kHz. Each wave has distinguishable characteristics in the time-frequency domain due to source shape and dispersion processes. Our methodology allows automatic detection of each type of event in the time-frequency decomposition thanks to their specific signature. Horizontal polarization attributes are also recovered in the time-frequency domain. This procedure is first applied to synthetic extremely low frequency time-series with different signal-to-noise ratios to test for robustness. We then apply it on real data: three stations of audio-magnetotelluric data acquired in Guadeloupe, oversea French territories. Most of analysed atmospherics and slow tails display linear polarization, whereas analysed whistlers are elliptically polarized. The diversity of lightning activity is finally analysed in an audio-magnetotelluric data processing framework, as used in subsurface prospecting, through estimation of the impedance response functions. We show that audio-magnetotelluric processing results depend mainly on the frequency content of electromagnetic waves observed in processed time-series, with an emphasis on the difference between morning and afternoon acquisition. Our new methodology based on the time-frequency signature of lightning-induced electromagnetic waves allows automatic detection and characterization of events in audio

  11. A LIMIT ON THE NUMBER OF ISOLATED NEUTRON STARS DETECTED IN THE ROSAT ALL-SKY-SURVEY BRIGHT SOURCE CATALOG

    Turner, Monica L.; Rutledge, Robert E.; Letcavage, Ryan; Shevchuk, Andrew S. H.; Fox, Derek B.

    2010-01-01

    Using new and archival observations made with the Swift satellite and other facilities, we examine 147 X-ray sources selected from the ROSAT All-Sky-Survey Bright Source Catalog (RASS/BSC) to produce a new limit on the number of isolated neutron stars (INSs) in the RASS/BSC, the most constraining such limit to date. Independent of X-ray spectrum and variability, the number of INSs is ≤48 (90% confidence). Restricting attention to soft (kT eff < 200 eV), non-variable X-ray sources-as in a previous study-yields an all-sky limit of ≤31 INSs. In the course of our analysis, we identify five new high-quality INS candidates for targeted follow-up observations. A future all-sky X-ray survey with eROSITA, or another mission with similar capabilities, can be expected to increase the detected population of X-ray-discovered INSs from the 8-50 in the BSC, to (for a disk population) 240-1500, which will enable a more detailed study of neutron star population models.

  12. FijiWingsPolarity: An open source toolkit for semi-automated detection of cell polarity.

    Dobens, Leonard L; Shipman, Anna; Axelrod, Jeffrey D

    2018-01-02

    Epithelial cells are defined by apical-basal and planar cell polarity (PCP) signaling, the latter of which establishes an orthogonal plane of polarity in the epithelial sheet. PCP signaling is required for normal cell migration, differentiation, stem cell generation and tissue repair, and defects in PCP have been associated with developmental abnormalities, neuropathologies and cancers. While the molecular mechanism of PCP is incompletely understood, the deepest insights have come from Drosophila, where PCP is manifest in hairs and bristles across the adult cuticle and organization of the ommatidia in the eye. Fly wing cells are marked by actin-rich trichome structures produced at the distal edge of each cell in the developing wing epithelium and in a mature wing the trichomes orient collectively in the distal direction. Genetic screens have identified key PCP signaling pathway components that disrupt trichome orientation, which has been measured manually in a tedious and error prone process. Here we describe a set of image processing and pattern-recognition macros that can quantify trichome arrangements in micrographs and mark these directly by color, arrow or colored arrow to indicate trichome location, length and orientation. Nearest neighbor calculations are made to exploit local differences in orientation to better and more reliably detect and highlight local defects in trichome polarity. We demonstrate the use of these tools on trichomes in adult wing preps and on actin-rich developing trichomes in pupal wing epithelia stained with phalloidin. FijiWingsPolarity is freely available and will be of interest to a broad community of fly geneticists studying the effect of gene function on PCP.

  13. Enhancement of chitosan-graphene oxide SPR sensor with a multi-metallic layers of Au–Ag–Au nanostructure for lead(II) ion detection

    Kamaruddin, Nur Hasiba [Department of Electric, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Bakar, Ahmad Ashrif A., E-mail: ashrif@ukm.edu.my [Department of Electric, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Yaacob, Mohd Hanif; Mahdi, Mohd Adzir [Wireless and Photonic Network Research Centre, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor (Malaysia); Zan, Mohd Saiful Dzulkefly [Department of Electric, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Shaari, Sahbudin [Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia)

    2016-01-15

    Highlights: • Tri-metallic Au–Ag–Au CS-GO SPR sensor was fabricated for the first time. • The tri-metallic nanostructure provided an enhanced evanescent field. • Successful functionalization of the CS-GO sensing layer. • Superior performance for lead(II) ion detection. - Abstract: We demonstrate the enhancement of surface plasmon resonance (SPR) technique by implementing a multi-metallic layers of Au–Ag–Au nanostructure in the chitosan-graphene oxide (CS-GO) SPR sensor for lead(II) ion detection. The performance of the sensor is analyzed via SPR measurements, from which the sensitivity, signal-to-noise ratio and repeatability are determined. The nanostructure layers are characterized using field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), X-ray diffraction (XRD), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). We showed that the proposed structure has increased the shift in the SPR angle up to 3.5° within the range of 0.1–1 ppm due to the enhanced evanescent field at the sensing layer-analyte interface. This sensor also exhibits great repeatability which benefits from the stable multi-metallic nanostructure. The SNR value of 0.92 for 5 ppm lead(II) ion solution and reasonable linearity range up to that concentration shows that the tri-metallic CS-GO SPR sensor gives a good response towards the lead(II) ion solution. The CS-GO SPR sensor is also sensitive to at least a 10{sup −5} change in the refractive index. The results prove that our proposed tri-metallic CS-GO SPR sensor demonstrates a strong performance and reliability for lead(II) ion detection in accordance with the standardized lead safety level for wastewater.

  14. ACToR Chemical Structure processing using Open Source ChemInformatics Libraries (FutureToxII)

    ACToR (Aggregated Computational Toxicology Resource) is a centralized database repository developed by the National Center for Computational Toxicology (NCCT) at the U.S. Environmental Protection Agency (EPA). Free and open source tools were used to compile toxicity data from ove...

  15. Detection of antibodies to both M. leprae PGL-I and MMP-II to recognize leprosy patients at an early stage of disease progression.

    Wang, Hongsheng; Liu, Weijing; Jin, Yali; Yu, Meiwen; Jiang, Haiqin; Tamura, Toshiki; Maeda, Yumi; Makino, Masahiko

    2015-11-01

    Antibodies to phenolic glycolipid (PGL)-I and major membrane protein (MMP)-II were evaluated for serodiagnosis of leprosy in Southwest China, and the role in predicting the occurrence of the disease in household contacts (HHCs) of leprosy was examined. Using PGL-I (natural disaccharide-octyl-bovine serum albumin) antigen-based diagnosis (IgM antibodies), we could detect 94.9% of multibacillary (MB) leprosy and 38.9% paucibacillary (PB) leprosy patients, whereas using MMP-II (IgG antibody), 88.1% of MB and 61.1% of PB patients were positive. By combining the 2 tests and considering either test positive as positive, 100% of MB patients and 72.2% of PB patients were found to test positive. Of the HHCs of leprosy, 28.3% and 30% had positive levels of PGL-I and MMP-II Abs, respectively. Seven out of 21 HHCs, who had high Ab titer to either antigen, developed leprosy during the follow-up period of 3 years. These data suggest that the measurement of both anti-PGL-I as well as anti-MMP-II antibodies could facilitate early detection of leprosy. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Source-specific sewage pollution detection in urban river waters using pharmaceuticals and personal care products as molecular indicators.

    Kiguchi, Osamu; Sato, Go; Kobayashi, Takashi

    2016-11-01

    Source-specific elucidation of domestic sewage pollution caused by various effluent sources in an urban river water, as conducted for this study, demands knowledge of the relation between concentrations of pharmaceuticals and personal care products (PPCPs) as molecular indicators (caffeine, carbamazepine, triclosan) and water quality concentrations of total nitrogen (T-N) and total phosphorous (T-P). River water and wastewater samples from the Asahikawa River Basin in northern Japan were analyzed using derivatization-gas chromatography/mass spectrometry. Caffeine, used as an indicator of domestic sewage in the Asahikawa River Basin, was more ubiquitous than either carbamazepine or triclosan (92-100 %). Its concentration was higher than any target compound used to assess the basin: caffeine, caffeine concentrations detected in wastewater effluents and the strongly positive mutual linear correlation between caffeine and T-N or T-P (R 2  > 0.759) reflect the contribution of septic tank system effluents to the lower Asahikawa River Basin. Results of relative molecular indicators in combination with different molecular indicators (caffeine/carbamazepine and triclosan/carbamazepine) and cluster analysis better reflect the contribution of sewage than results obtained using concentrations of respective molecular indicators and cluster analysis. Relative molecular indicators used with water quality parameters (e.g., caffeine/T-N ratio) in this study provide results more clearly, relatively, and quantitatively than results obtained using molecular indicators alone. Moreover, the caffeine/T-N ratio reflects variations of caffeine flux from effluent sources. These results suggest strongly relative molecular indicators are also useful indicators, reflecting differences in spatial contributions of domestic sources for PPCPs in urban areas.

  17. Selective visual detection of Pb(II) ion via gold nanoparticles coated with a dithiocarbamate-modified 4′-aminobenzo-18-crown-6

    Mehta, Vaibhavkumar N.; Kailasa, Suresh Kumar; Solanki, Jignasa N.

    2014-01-01

    We have developed a crown ether based selective colorimetric sensing scheme for the determination of Pb(II) ion by using gold nanoparticles modified with dithiocarbamate derivative of 4′-aminobenzo-18-crown-6 that acts as a colorimetric probe. Monodisperse Au-NPs were prepared by reacting 4′-aminobenzo-18-crown-6 with carbon disulfide to generate the dithiocarbamate ligand which was then added to the Au-NPs to form a supramolecular assembly on their surface. The Au-NPs modified in this way undergo aggregation in the presence of Pb(II) ions, and this causes the color to change from red to blue. The Pb(II)-induced aggregation can be monitored by using UV-visible spectrometry and even with the bare eye. The absorbance ratio (A 650nm /A 520nm ) is linearly related to the concentration of Pb(II) in the 0.1 to 75 μM range (with a correlation coefficient of 0.9957), and the detection limit is 50 nM which is lower than the allowable level (75 nM) as defined by the US EPA. The method was successfully applied to the determination of Pb(II) in spiked water samples. (author)

  18. Upgrade for detection system of JARREL ASH 70-000 atomic emission spectrography with source of arc - spark

    Santa Cruz D E; Grau F N; Bellavigna H J; Garavaglia R N; Fernandez R O; Servant R

    2012-01-01

    Methodologies used in spectrochemical analysis have showed breakthroughs in last decades due to the newest digital technologies. The simultaneous determination of multiple elements in a short time has been allowed by the development of solid state multichannel detectors. Since its beginning CNEA has developed several spectroscopic methodologies that have been applied to the area of fuels and specific materials of the nuclear activity. The Analytical Chemistry Department has an atomic emission spectrograph with a source of arc/spark whose focal length is 3.4 meters and a spectral dispersion from 2.5 to 5 A/mm. This equipment was originally equipped with photographic detection. This feature although allowed the simultaneous detection of multiple elements, their response (photographic plate) has been not linear and their data's treatment has been very complex. Two alternatives of digital detection have been examined: CCD2 and CMOS3 according to the progress achieved in the instrumentation that is applied to similar techniques. After exhaustive evaluation an arrangement of 9 linear CCD detectors located in the focal plane originally occupied by 2 x10 inch photographic plates was chosen. The software provided by the manufacturer has been insufficient for cover our analytical necessities due to the requirements of our instrumental application. This led to develop an own program for our applications. Today, our detection system includes an assembly of 7 detectors and an acquisition program with basic control that has been developed in-house. Calibration curves for some chemical elements have shown very promising results, the sensitivity has increased at least 10 times and an important improvement of accuracy of the measurements has also been achieved thanks to our modification. An upgrade with an associated database that will allow obtaining spectra in 3D configuration and extend the instrumental capabilities to second order is being prepared (author)

  19. Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

    Joo, Youngdo; Yu, Inha; Park, Insoo; Chun, Myunghwan; Lee, Byung-Joon; Hwang, Ilmoon; Ha, Taekyun; Shin, Seunghwan; Sohn, Younguk

    2014-01-01

    After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out

  20. Dualband MW/LW Strained Layer Superlattice Focal Plane Arrays for Satellite-Based Wildfire Detection, Phase II

    National Aeronautics and Space Administration — Infrared focal plane arrays (FPAs) based on Type-II strained layer superlattice (SLS) photodiodes have recently experienced significant advances. In Phase I we...