WorldWideScience

Sample records for iec qualification standards

  1. Comparison of IEEE383-2003 and IEC60505-2004 standards for harmonization of environmental qualification procedure of electric cable

    International Nuclear Information System (INIS)

    Kim, Jong Seog; Jeong, Sun Chul; Park, Kyung Heum; Jang, Kyung Nam

    2010-01-01

    Needs for harmonization of international equipment qualification(EQ) standards have been raised several years due to purchasing problem of nuclear equipment supplied from abroad country. To meet the regulatory requirement of domestic nuclear power plant, manufacturers have to qualify their equipment in accordance with each standard such as IEEE, IEC and RCC-E. Double qualification increase the equipment cost, which result in high construction cost. Even the unification of each standard have been discussed several years, we have got the long way to go yet. Comparison and harmonization of each international standard will give help to purchase the equipment qualified by not endorsed standard. Environmental qualification, seismic qualification and EMI/EMC qualification are major targets for harmonization. Since concern about cable qualification of 60 years life has been raised recently, harmonization of cable qualification standard also needs to be discussed. KEPRI launched a project for harmonization of EQ relative standards such as IEEE, IEC and RCC-E. A study for harmonization of IEEE323 and IEC60780 is known in progress by IEEE committee. In this paper, harmonization of international standards for cable qualification will be discussed. IEEE383 standard is qualification standard for electric cable broadly used in Asian pacific area while IEC60505 is mostly used in European area. Since these two standards have different requirements for environmental qualification of cable, problem can be happened in the plant site when they purchase cable qualified by not endorsed standard. IEEE383-2003 and IEC60505-2004 is the latest version of each standard. Comparison results and recommendations for harmonization of these two standards are introduced herein

  2. Comparison and Analysis of IEEE 344 and IEC 60980 standards for harmonization of seismic qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Lee, Young Ok; Kim, Jong Seog; Seo, Jeong Ho; Kim, Myung Jun

    2011-01-01

    The seismic qualification of safety related equipment in nuclear power plants should demonstrate an equipment's ability to perform its safety function during/or after the time it is subjected to the forces resulting from one SSE. In addition, the equipment must withstand the effects of a number of OBEs, preceding the SSE. IEEE 344 and IEC 60980 present the criteria for establishing procedures demonstrating that the Class 1E equipment can meet its performance requirement during seismic events. Currently, IEEE 344 is used for regulation of nuclear power plant in the United State whereas IEC 60980 is mainly used in Europe. In particular, NPPs of France and China apply with RCC-E and GB that are domestic standards, respectively. Equipment supplier and Utility have difficulties because of different applicable standards. Equipment supplier to export S/R components/equipment to other standard area performs additional seismic qualification. For example, equipment are qualifies according to IEC 60980, RCC-E, GB although they have been qualified in accordance with IEEE 344. Also, utility to attempt power up-rate, life extension of NPP constructed under rules of RCC-E such as Ulchin NPP 1 and 2 has similar difficulties. RCC-E endorses IEC 60980 and GB is almost same as IEC 60980 except minor difference of earthquake environment definition. Therefore this paper surveys the similarities and differences between IEEE 344 and IEC 60980. In addition, this paper considers how the two sets of standards may be used in a complementary fashion to be possible using one or the other standard area

  3. Harmonization of IEEE323 and IEC60780 standards For Environmental Qualificaiton of Electric Equipment

    International Nuclear Information System (INIS)

    Kim, Jong Seog

    2009-01-01

    IEEE323 standard has been widely used for the qualification of electric equipment in Asian pacific area while IEC6070 has been mostly used in European area. Since each plant use different standard for environmental qualification, manufacturer has to perform the qualification test twice in accordance with each standard. Problem also can be happened in the plant site when they are going to purchase equipment qualified by different qualification standard which are not used in his plant. The need of harmonization of each standard has been raised several years and it is known that some studies are in progress by IEEE committee. KEPRI has a plan of comparing EQ relative standards of IEEE, IEC and RCC in 2009. In this paper, brief comparing result between IEEE323 and IEC60780 and the proper harmonization method is introduced

  4. Qualification of a Human-System Interface to Meet IEC 61513

    International Nuclear Information System (INIS)

    Malcom, Scott; Kim, Sun Ho; Macdonald, Marienna

    2011-01-01

    challenging. The ACCIS team has relied on the services of an external certified functional safety expert to provide assistance on interpreting the IEC standards and assisting with the safety analyses that is required in support of compliance arguments. In particular, the expert provided leadership and guidance when performing the Failure Modes and Effects Analysis (FMEA), Failure Modes, Effects and Diagnostics Analysis (FMEDA), and software Hazards and Operability Analysis (HAZOP) and has helped to prepare arguments that demonstrate compliance to each IEC requirement. The external certified functional safety expert performed a preliminary assessment to determine the feasibility of qualifying ACCIS, followed later by a detailed assessment to identify the compliance gaps requiring remedial action. Both audits confirmed that achieving IEC compliance is well within the capabilities of the ACCIS product. Work to close identified gaps ensued. A full qualification cycle was completed and will support qualification activities at the application level

  5. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  6. Adopting ISO 9712:2005 and ISO/IEC 17024:2003 as Philippine national standard for NDT for global competitiveness

    International Nuclear Information System (INIS)

    Banaga, Renato T.; Mateo, Alejandro J.

    2005-01-01

    This paper describes and promotes the adoption of ISO 9712: 2005 edition and the ISO/IEC 17024: 2003 edition by the Philippines to be globally competitive. ISO 9712 is a standard for qualifications and certification of nondestructive testing (NDT) personnel while ISO/IEC 17024 is conformity assessment-general requirements for bodies operating certification of persons. ISO 9712 defies that the effectiveness of an application of nondestructive testing depends on the capabilities and qualifications of personnel performing the NDT test. The Philippines through the national certifying body (NCB) implements the certification of proficiency of NDT personnel in accordance with the Philippine National Standards (PNS-146: 1998) This standard (formerly PNS-146: 1987) was originally based from the draft ISO/TC-135/SC7N35.3 and was later revised to conform to the latest ISO FDIS 9712: 1997 and rename PNS-146: 1998. Now with the issuance of the latest ISO 9712:2005 edition and to keep abreast with the current trends of NDT technology, present time and conditions dictates for us to revise our NDT personnel certification to the latest edition of ISO 9712. The International Atomic Energy Agency (IAEA) supports the establishment of a common NDT standard. The IAEA is promoting af financially supporting the establishment in developing countries of only one NDT standard. The IAEA through the Regional Cooperative Agreement (RCA) has initiated the harmonization of the NDT qualification and certification of personnel in the RCA member states. In October 2001, the IAEA sponsored the Dhaka meeting where the International Committee for Nondestructive Testing (ICNDT), Asia-Pacific Committee (APCNDT) and RCA member states representatives drafted a Mutual Recognition Agreement (MRA) for the Asia-Pacific NDT (APCNDT) personnel certification schemes acording to ISO 9712. Last August 2005, IAEA/RCA sponsored the Colombo meeting for the harmonization of regional NDT applying ISO 9712 and ISO/IEC

  7. China and IEC international standardization activities

    Institute of Scientific and Technical Information of China (English)

    Su Zhongmin; Guo Chenguang

    2006-01-01

    @@ International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total.

  8. Standardization in SEK/IEC 2012; Standardisering inom SEK/IEC 2012

    Energy Technology Data Exchange (ETDEWEB)

    Olausson, Susanne

    2013-02-15

    This report describes the work of standardization in the electrotechnical area and collaboration in selected committees of SEK, IEC and CENELEC. Electrotechnical standardization is traditionally an area characterized of large international collaboration, cooperation between government agencies, manufacturers and users. Standardization work has previously been a natural part of power companies' activities related to the extensive expansion activities, own construction business and to generally maintain a good knowledge base of staff. Taking part in the establishment of standards have been a good way to ensure long-term approach made in investments and a guarantee of open competition between manufacturers. Maintenance efforts have also been reduced by using established standards. The acceleration of technological progress has, however, increased pressure on standardization organizations, committee work etc. to keep up with time before the de facto standards have been applied in excessive degree. Reregulation of the electricity market in Sweden has also led to a difference in the standardization process. An increasing number of experts who have worked with standards is currently located at power companies consultancy activities. What was once a natural part of the power companies' internal skills provision today are exposed to a commercial assessment. In 1994 Elforsk was appointed by the owners the task of coordinating the power companies' joint standardization work within specifically electrical engineering. After an initial assessment of the activities was decided that remunera would be paid to the members in SEK, IEC and CENELEC who either participated in selected projects with international character or was either secretary or chairman of the Swedish technical committees (SEK)

  9. Competence Requirements of ISO/IEC Standards for Information Security Professionals

    Directory of Open Access Journals (Sweden)

    Natalia G. Miloslavskaya

    2017-11-01

    Full Text Available The rapid progress in the filed of information security (IS puts one in a need of periodic revision of professional competencies (formulated in the federal state educational standards –FSESs and working functions (formulated in the professional standards – PSs. Under these conditions, a timely reaction to everything new that emerges or will appear in modern regulatory documents (primarily in standards is extremely important. We make a forecast for the content of the ISO/IEC 27021 and ISO/IEC 19896 standards drafted by the International Organization for Standardization (ISO, which should contain the requirements for the competencies of IS management system professionals and the competence of IS testers and evaluators. Our forecast takes into account the requirements of the ISO/IEC 27000 standard group and the recommendations of the European e-Competence Framework e-CF 3.0.

  10. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  11. Methods for qualification of highly reliable software - international procedure

    International Nuclear Information System (INIS)

    Kersken, M.

    1997-01-01

    Despite the advantages of computer-assisted safety technology, there still is some uneasyness to be observed with respect to the novel processes, resulting from absence of a body of generally accepted and uncontentious qualification guides (regulatory provisions, standards) for safety evaluation of the computer codes applied. Warranty of adequate protection of the population, operators or plant components is an essential aspect in this context, too - as it is in general with reliability and risk assessment of novel technology - so that, due to appropriate legislation still missing, there currently is a licensing risk involved in the introduction of digital safety systems. Nevertheless, there is some extent of agreement within the international community and utility operators about what standards and measures should be applied for qualification of software of relevance to plant safety. The standard IEC 880/IEC 86/ in particular, in its original version, or national documents based on this standard, are applied in all countries using or planning to install those systems. A novel supplement to this standard, document /IEC 96/, is in the process of finalization and defines the requirements to be met by modern methods of software engineering. (orig./DG) [de

  12. ISO/IEC 38500 the IT governance standard

    CERN Document Server

    Calder, Alan

    2008-01-01

    The emergence of ISO/IEC 38500 - the international standard for the corporate governance of information and communication technology - puts boards around the world in a position from which they can take effective action to apply core governance principles to their information and communication technology.

  13. Qualification test on class 1E charger and inverter in nuclear power plant

    International Nuclear Information System (INIS)

    Li Mingcheng; Lin Jian; Fu Mingxing; Xu Benfu; Ma Peifeng

    2014-01-01

    The qualification approach for class lE electrical equipment was introduced, based on IEC, IEEE and RCC-E standards and technical documents. Combined with a lot of practical experience, the qualification scheme for class lE charger and inverter was developed. The component evaluation, performance and stress test, EMC test, seismic test and software qualification for the equipment were analyzed in detail. (authors)

  14. Standard IEC 61850 substation automation

    Energy Technology Data Exchange (ETDEWEB)

    Bricchi, A.; Mezzadri, D. [Selta, Tortoreto (Italy)

    2008-07-01

    The International Electrotechnical Commission (IEC) 61850 standard is the reference communication protocol for all electrical substations protection and control systems. It creates models of all the elements and functionalities of an electrical substation, including physical elements such as switches or circuit breakers, as well as protection, control and monitoring functionalities. Network managers need to renew power substation automation and control systems in order to improve the efficiency and quality of services offered by electric utilities. Selta has proposed a new integrated solution for the automation of power substations which is fully compliant with the IEC 61850 norms. The solution involves the integration of control, automation, protection, monitoring and maintenance functions and applies leading edge technology to its systems, particularly for the TERNA network. The system is based on the use of many electronic devices at a power plant, each one with a specialized function, and all interconnected via a Station LAN. This solution, was tested on the TERNA network in Italy, in VHV and HV stations. It was shown to offer many advantages, such as an architecture based on full interoperability between control, monitoring and protection equipment; centralized and distributed automation; a LAN station that allows full interoperability between different bay units and protection relays in order to integrate equipment from various suppliers; the integration of automation systems in existing bay units and protection relays equipped with standard communication buses or with proprietary interfaces; and time synchronization for the entire system through a station GPS reception system. 10 refs., 1 tab., 7 figs.

  15. Thirty years of international nuclear standards in ISO and IEC

    International Nuclear Information System (INIS)

    Becker, K.

    1991-01-01

    Of over 4700 nuclear and radiation protection standards, laws, regulations, recommendations, etc., which have been issued by 52 countries and several governmental international organizations such as IAEA, or non-government organizations such as ICRP, ICRU, ISO and IEC, more than 90% are national, and more than half of those of a non-regulatory nature. Both number and importance of international standards are, however, increasing. The two most important non-governmental international standards organizations are the International Organization for Standardization (ISO), which founded a Technical Committee (TC) 85 'Nuclear Energy' with several Sub-Committees in 1957, and the closely associated International Electrotechnical Commission (IEC) with its TC 45 'Nuclear Instrumentation' formed in 1960. There are over 20 member countries actively participating in the work in each of them, with additional observer countries and liaison to the relevant other international organizations. A brief review is given on some of the experience which has been gained by ISO/TC 85 and IEC/TC 45, and its work program and accomplishments, considering in particular recent developments. It covers nuclear safety and instrumentation, radiation protection, and the nuclear fuel cycle, as well as interface issues including definitions and terminology, interaction of the activities with the work of other national and international bodies, etc. Some problem areas are also briefly discussed. (orig.)

  16. Application of Microprocessor-Based Equipment in Nuclear Power Plants - Technical Basis for a Qualification Methodology

    International Nuclear Information System (INIS)

    Korsah, K.

    2001-01-01

    This document (1) summarizes the most significant findings of the ''Qualification of Advanced Instrumentation and Control (I and C) Systems'' program initiated by the Nuclear Regulatory Commission (NRC); (2) documents a comparative analysis of U.S. and European qualification standards; and (3) provides recommendations for enhancing regulatory guidance for environmental qualification of microprocessor-based safety-related systems. Safety-related I and C system upgrades of present-day nuclear power plants, as well as I and C systems of Advanced Light-Water Reactors (ALWRs), are expected to make increasing use of microprocessor-based technology. The Nuclear Regulatory Commission (NRC) recognized that the use of such technology may pose environmental qualification challenges different from current, analog-based I and C systems. Hence, it initiated the ''Qualification of Advanced Instrumentation and Control Systems'' program. The objectives of this confirmatory research project are to (1) identify any unique environmental-stress-related failure modes posed by digital technologies and their potential impact on the safety systems and (2) develop the technical basis for regulatory guidance using these findings. Previous findings from this study have been documented in several technical reports. This final report in the series documents a comparative analysis of two environmental qualification standards--Institute of Electrical and Electronics Engineers (IEEE) Std 323-1983 and International Electrotechnical Commission (IEC) 60780 (1998)--and provides recommendations for environmental qualification of microprocessor-based systems based on this analysis as well as on the findings documented in the previous reports. The two standards were chosen for this analysis because IEEE 323 is the standard used in the U.S. for the qualification of safety-related equipment in nuclear power plants, and IEC 60780 is its European counterpart. In addition, the IEC document was published in

  17. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  18. Review and Outlook of China Electronic and IT Industry Footprints in IEC International Standardization Activities

    Institute of Scientific and Technical Information of China (English)

    Hu Jingping

    2006-01-01

    @@ Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic technology field aiming at promoting international trade and technology cooperation and exchange, improving product and service quality, upgrading productivity and protecting the environment as well as human health and safety. Most countries worldwide adopt standards developed and promulgated by IEC, providing a platform to international trade and technical exchange. China has being a member since 1957. Electronic and IT are the most developed and energetic filed in recent decades. Number of IEC TC/SC specialized in electronic and IT amounts up to 52.

  19. Nuclear Knowledge Capture and IEC Standards

    International Nuclear Information System (INIS)

    Sheldon, J.

    2016-01-01

    Full text: An International Standard is a document, established by consensus and approved by a recognized body that provides, for common and repeated use, rules, guidelines or characteristics for activities or their results, aimed at the achievement of the optimum degree of order in a given context. As such, it is a mechanism for sharing knowledge in a particular field. The consensus process used to approve the content of standards ensures that the content is essentially peer-reviewed. This presentation will explain how International Standards are developed and used and their importance in the dissemination of scientific and engineering information. It will also explain the role of the IEC in ensuring that the process for developing standards meets the core principles of the Code of Good Practice of the WTO TBT agreement: transparency, openness, impartiality and consensus, effectiveness and relevance, coherence, and addressing the concerns of developing countries. (author

  20. IEC 61850 and IEC 62351 Cyber Security Acceleration Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Clements, Samuel L.; Edgar, Thomas W.; Manz, David O.

    2012-04-01

    The purpose of this workshop was to identify and discuss concerns with the use and adoption of IEC 62351 security standard for IEC 61850 compliant control system products. The industry participants discussed performance, interoperability, adoption, challenges, business cases, and future issues.

  1. From IEC 61131 to IEC 61499 for Distributed Systems: A Case Study

    Directory of Open Access Journals (Sweden)

    Christian Gerber

    2008-02-01

    Full Text Available A new concept for distributed control systems based on the new IEC 61499 standard is tested in this work in cooperation with LAE Engineering GmbH, a medium-sized company. Based on a catalogue of requirements, a customer-related testbed is developed. In the following this testbed is used as a reference to realise an IEC 61499 compliant-distributed control system based on PC technics. By doing this, rules are defined to convert user-owned IEC 61131 function blocks to IEC 61499 compliant function blocks. Concluding, some trends for IEC 61499-based distributed control systems will be summarised.

  2. IEC 61850. Integrated supervision of auxiliary power equipment; IEC 61850. Prozess und Eigenbedarf wachsen zusammen

    Energy Technology Data Exchange (ETDEWEB)

    Ostertag, Robert; Jung, Matthias [Siemens AG, Erlangen (Germany)

    2009-07-01

    It is state of technology today: Having process control and auxiliary power control integrated in one DCS. The integration is based on the international standard IEC 61850 which allows standardization of electrical structures from the process interface up to the DCS level. Modern control systems are designed to realize a system structure according to IEC 61850. A wide range of systems is available from systems with interfaces to realize a standardized data exchange up to systems with a complete integration of the standard IEC 61850. (orig.)

  3. Implementation of Electrical Simulation Model for IEC Standard Type-3A Generator

    DEFF Research Database (Denmark)

    Subramanian, Chandrasekaran; Casadei, Domenico; Tani, Angelo

    2013-01-01

    This paper describes the implementation of electrical simulation model for IEC 61400-27-1 standard Type-3A generator. A general overview of the different wind electric generators(WEG) types are given and the main focused on Type-3A WEG standard models, namely a model for a variable speed wind tur...

  4. ISO/IEC 17025 laboratory accreditation of NRC Acoustical Standards Program

    Science.gov (United States)

    Wong, George S. K.; Wu, Lixue; Hanes, Peter; Ohm, Won-Suk

    2004-05-01

    Experience gained during the external accreditation of the Acoustical Standards Program at the Institute for National Measurement Standards of the National Research Council is discussed. Some highlights include the preparation of documents for calibration procedures, control documents with attention to reducing future paper work and the need to maintain documentation or paper trails to satisfy the external assessors. General recommendations will be given for laboratories that are contemplating an external audit in accordance to the requirements of ISO/IEC 17025.

  5. IEC 61850: integrating substation automation into the power plant control system; IEC 61850: Integration der Schaltanlagenautomatisierung in die Kraftwerksleittechnik

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany)

    2008-07-01

    The new communication standard IEC 61850 has been developed in the substation automation domain and was released 2004 as a worldwide standard. Meanwhile IEC 61850 is already established in many substation automation markets. The paper discusses the implementation of IEC 61850 integrating process control and substation automation into one consistent system in a power plant. (orig.)

  6. Qualification standard for photovoltaic concentrator modules

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, R.; Kurtz, S.; Bottenberg, W. R.; Hammond, R.; Jochums, S. W.; McDanal, A. J.; Roubideaux, D.; Whitaker, C.; Wohlgemuth, J.

    2000-05-05

    The paper describes a proposed qualification standard for photovoltaic concentrator modules. The standard's purpose is to provide stress tests and procedures to identify any component weakness in photovoltaic concentrator modules intended for power generation applications. If no weaknesses are identified during qualification, both the manufacturer and the customer can expect a more reliable product. The qualification test program for the standard includes thermal cycles, humidity-freeze cycles, water spray, off-axis beam damage, hail impact, hot-spot endurance, as well as electrical tests for performance, ground continuity, isolation, wet insulation resistance, and bypass diodes. Because concentrator module performance can not be verified using solar simulator and reference cell procedures suitable for flat-plate modules, the standard specifies an outdoor I-V test analysis allowing a performance comparison before and after a test procedure. Two options to this complex analysis are the use of a reference concentrator module for side-by-side outdoor comparison with modules undergoing various tests and a dark I-V performance check.

  7. Leveraging Software Architectures through the ISO/IEC 42010 standard: A Feasibility Study

    NARCIS (Netherlands)

    Tamburri, D.A.; Lago, P.; Muccini, H.; Proper, E.; Lankhorst, M.; Schoenherr, M.

    2011-01-01

    The state of the practice in enterprise and software architecture learnt that relevant architectural aspects should be illustrated in multiple views, targeting the various concerns of different stakeholders. This has been expressed a.o. in the ISO/IEC 42010 Standard on architecture descriptions. In

  8. IEC Newsletter, No. 53/3 (2015)

    International Nuclear Information System (INIS)

    2015-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Prepared to Respond International Conference on Global EPR; Launch of EPRIMS; First meeting of EPR Standards Committee; IEC and French experts test assessment and prognosis arrangements; IEC and Swiss counterparts conduct an assessment and prognosis drill; Consultancy on CANDUspecific EALs; Regional Workshops; Recently reported events; Member State preparedness; IEC welcomes young visitors on Bring Your Children to Work day

  9. Design and qualification of a RTOS for safety class nuclear C and I applications

    International Nuclear Information System (INIS)

    Wakankar, A.; Khan, Arindam; Kalra, Mohit; Mitra, Raka; Aravamuthan, G.; Bhattacharjee, A.K.; Vaidya, U.W.; Mayya, Anuradha

    2014-01-01

    Real Time Operating System (RTOS) is a critical component of embedded systems. International standards such as IEC60880 used for development of Instrumentation and Control (I and C) system in nuclear power plants require rigorous qualification of all software components. In this paper, we describe our experience in the design and qualification of ESOS; an in-house configured RTOS from a commodity RTOS available with source code. The qualification activities include static and dynamic analysis, timing analysis and rigorous program analysis. We discuss how rigorous program analysis was used to uncover a subtle bug in the implementation. We also discuss the applications where this qualified RTOS has been successfully used. (author)

  10. Characterization and standardized radiation qualities deployment - NBR IEC 61225 - in a animal irradiator

    International Nuclear Information System (INIS)

    Carvalho, Samara; Magalhaes, Luis Alexandre Goncalves

    2015-01-01

    The present work consisted in the determination of additional aluminum filters, so that the Animal Irradiator of the Laboratory of Radiological Sciences-UERJ can operate in accordance with standard IEC 61267: 2005. In order to perform the measurements necessary for the determination of these filters, it was developed an additional filter positioning system coupled to the X-ray tube. The determination of these filters was performed to obtain the first half value layer (HVL) according to the window with the values given by the IEC 61267: 2005. It was used IPEN SRS-78 (Institute of Physics and Engineering in Medicine) software for the estimation of the total amount of the additional filtration through the measurements values of the first HVL. (author)

  11. Wind Plant Models in IEC 61400-27-2 and WECC - latest developments in international standards on wind turbine and wind plant modeling

    DEFF Research Database (Denmark)

    Fortmann, Jens; Miller, Nicholas; Kazachkov, Yuri

    2015-01-01

    This paper describes the latest developments in the standardization of wind plant and wind plant controller models. As a first step IEC TC88 WG 27 and WECC jointly developed generic wind turbine models which have been published by WECC in 2014 and IEC in 2015 as IEC 61400-27-1, which also include...

  12. Information security in accordance with ISO/IEC 27000

    OpenAIRE

    Košćak , Damjan

    2011-01-01

    The diploma assignment discusses Information Technology Security according to standards ISO/IEC 27001 and ISO/IEC 27002. Diploma consists of two parts. In the first part of the diploma a theoretical bases of information security are presented. The second part presents the introduction of ISO/IEC 27001 security standard in the company »X« in wich I performed a practical training. In the closure my diploma work is upgraded with results of my research work and their analysis as well as wit...

  13. Safety critical systems handbook a straightforward guide to functional safety : IEC 61508 (2010 edition) and related standards

    CERN Document Server

    Smith, David J

    2010-01-01

    Electrical, electronic and programmable electronic systems increasingly carry out safety functions to guard workers and the public against injury or death and the environment against pollution. The international functional safety standard IEC 61508 was revised in 2010, and this is the first comprehensive guide available to the revised standard. As functional safety is applicable to many industries, this book will have a wide readership beyond the chemical and process sector, including oil and gas, power generation, nuclear, aircraft, and automotive industries, plus project, instrumentation, design, and control engineers. * The only comprehensive guide to IEC 61508, updated to cover the 2010 amendments, that will ensure engineers are compliant with the latest process safety systems design and operation standards* Helps readers understand the process required to apply safety critical systems standards* Real-world approach helps users to interpret the standard, with case studies and best practice design examples...

  14. Emergency Management. Functional Area Qualification Standard

    National Research Council Canada - National Science Library

    2004-01-01

    .... In support of this goal, the competency requirements defined in the Technical Qualification Standards should be aligned with and integrated into the recruitment and staffing processes for technical positions...

  15. The IEC-publication 336/1981 - new formulation of the standards for X-ray foci

    International Nuclear Information System (INIS)

    Geldner, E.; Schnitger, H.

    1982-01-01

    With the new IEC-standard for foci a clear distinction has been made between application oriented focus classification, expressed by the focus nominal value as a dimensionless number and the detectable real geometric focus measured in the sense of the principle 'Truth in advertising'. Now, even regions of a size [de

  16. The role of the IEC and ISO in radiological protection

    International Nuclear Information System (INIS)

    White, D.F.

    1976-01-01

    The history, objectives, structures and functions of the International Electrotechnical Commission (IEC) and the International Organisation for Standardisation (ISO) are summarized. The IEC is affiliated to the ISO as its electrical division, but has technical and financial autonomy. Member countries of the EEC may be committed to the adoption of their formal agreements ('Standards') if these become incorporated as Directives. The national standardisation organisations, such as BSI in the U.K., form national committees and are responsible for submitting to the IEC the co-ordinated national viewpoints on particular subjects. The overall links between the technical committees and sub-committees of the ISO, IEC and BSI in the field of radiological protection are tabulated, and the relevant International Standards produced, or in the course of preparation, by the appropriate committees of the ISO and the IEC are listed. The bulk of the effort of the BSI committees is now aimed at the production of acceptable international standards. Compatible national standards then follow. This policy is in contrast to the earlier initial emphasis on national standards, and the improved international collaboration has had two welcome effects. The selection of proposals for standards is more critical, and compatibility with the relevant ICRP and ICRU publications is almost a prerequisite for any international standard. (U.K.)

  17. Compliance of the CERN electronics used by the LHC Cryogenic System with the Electromagnetic Compatibility (EMC) Norm IEC 61000 4-4

    CERN Document Server

    Casas, J

    2011-01-01

    Within the ITER-CERN collaboration agreement, task “PROCUREMENT OF CRYOGENIC THERMOMETERS TO MONITOR ITER MAGNETS AND FEEDER TEMPERATURES”, CERN is recommending the use by ITER of LHC like electronics for the temperature channels. ITER require that any electronic equipment shall be qualified according to the standard IEC 61000 4-4 that refers to the Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques, Section 4: Electrical fast transient/burst immunity test (EFT/B). This document describes the qualification procedure and the results for the LHC like temperature measurement chains according to the procedures described in the standard.

  18. IEC Newsletter, No. 51, First Quarter, 2015

    International Nuclear Information System (INIS)

    2015-06-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: IEM 8; Internal Full Response Exercise; Board of Governors establishes Safety Requirements in EPR as IAEA Safety Standard; ConvEx-2a; EURDEP Meeting; Train the Trainers Workshop on Medical Aspects of EPR; EPR-Medical 2005 Review Process; EPRIMS; Member State Preparedeness; EPREV Mission to Kenya; RENEB Meeting; Update by Finland of its RANET registration; Recent Events; Upgraded IEC videoconferencing infrastracture; EPREG Meeting and Forthcoming Event: EPR Conference

  19. Impact of the draft DOE Training and Qualification Standard on an established training and qualification program

    International Nuclear Information System (INIS)

    Taylor, R.G.; Worley, C.A.

    1999-01-01

    One of the provisions of Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 97-2 was that the US Department of Energy (DOE) hor e llipsis Develop and institute ahor e llipsiscourse in criticality and criticality safety hor e llipsis to serve as the foundation for a program of formal qualification of criticality engineers. In response, a draft DOE standard establishing requirements for a formal qualification program for nuclear criticality safety (NCS) engineers has been prepared and is currently in review. The Oak Ridge Y-12 plant implemented a formal training and qualification program for NCS engineers in 1995. The program complies with existing DOE requirements. The program was developed using a performance-based systematic approach to training and is accomplished through structured mentoring where experienced personnel interact with candidates through various learning exercises. Self-study, exercises, and work under instruction are all utilized. The candidate's performance is evaluated by mentors and oral boards. Competency gained through experience at other sites can also be credited. Technical portions of the program are primarily contained in an initial Engineer-in-Training segment and in subsequent task-specific qualifications. The Engineer-in-Training segment exposes the candidate to fundamental NCS concepts through example problems; ensures the initial compliance training requirements are met; and includes readings from applicable procedures, technical documents, and standards. Upon completion of this initial training, candidates proceed to task qualifications. Tasks are defined NCS activities such as operational reviews, criticality safety evaluations, criticality safety computations, criticality accident alarm system (CAAS) evaluations, support for emergency management, etc. Qualification on a task basis serves to break up training into manageable pieces and expedites qualification of candidates to perform specific production activities. The

  20. TU-G-213-01: IEC and US Committee Activities and Organizational Structure

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  1. On the Implementation of the IEC 61850 Standard: Will Different Manufacturer Devices Behave Similarly under Identical Conditions?

    Directory of Open Access Journals (Sweden)

    Mohamad El Hariri

    2016-12-01

    Full Text Available Standardization in smart grid communications is necessary to facilitate complex operations of modern power system functions. However, the strong coupling between the cyber and physical domains of the contemporary grid exposes the system to vulnerabilities and thus places more burden on standards’ developers. As such, standards need to be continuously assessed for reliability and are expected to be implemented properly on field devices. However, the actual implementation of common standards varies between vendors, which may lead to different behaviors of the devices even if present under similar conditions. The work in this paper tested the implementation of the International Electro-technical Commission’s Generic Object Oriented Substation Event GOOSE (IEC 61850 GOOSE messaging protocol on commercial Intelligent Electronic Devices (IEDs and the open source libiec61850 library—also used in commercial devices—which showed different behaviors in identical situations. Based on the test results and analysis of some features of the IEC 61850 GOOSE protocol itself, this paper proposes guidelines and recommendations for proper implementation of the standard functionalities.

  2. Implementation of IEC standard models for power system stability studies

    Energy Technology Data Exchange (ETDEWEB)

    Margaris, Ioannis D.; Hansen, Anca D.; Soerensen, Poul [Technical Univ. of Denmark, Roskilde (Denmark). Dept. of Wind Energy; Bech, John; Andresen, Bjoern [Siemens Wind Power A/S, Brande (Denmark)

    2012-07-01

    This paper presents the implementation of the generic wind turbine generator (WTG) electrical simulation models proposed in the IEC 61400-27 standard which is currently in preparation. A general overview of the different WTG types is given while the main focus is on Type 4B WTG standard model, namely a model for a variable speed wind turbine with full scale power converter WTG including a 2-mass mechanical model. The generic models for fixed and variable speed WTGs models are suitable for fundamental frequency positive sequence response simulations during short events in the power system such as voltage dips. The general configuration of the models is presented and discussed; model implementation in the simulation software platform DIgSILENT PowerFactory is presented in order to illustrate the range of applicability of the generic models under discussion. A typical voltage dip is simulated and results from the basic electrical variables of the WTG are presented and discussed. (orig.)

  3. Implementation of the OECD principles of good laboratory practice in test facilities complying with a quality system accredited to the ISO/IEC 17025 standard.

    Science.gov (United States)

    Feller, Etty

    2008-01-01

    Laboratories with a quality system accredited to the ISO/IEC 17025 standard have a definite advantage, compared to non-accredited laboratories, when preparing their facilities for the implementation of the principles of good laboratory practice (GLP) of the Organisation for Economic Co-operation and Development (OECD). Accredited laboratories have an established quality system covering the administrative and technical issues specified in the standard. The similarities and differences between the ISO/IEC 17025 standard and the OECD principles of GLP are compared and discussed.

  4. Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

    International Nuclear Information System (INIS)

    Mahoney, Kelly; Robertson, Henry

    2009-01-01

    This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R and D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC.

  5. ISO/IEC 17025: custos de acreditação em uma universidade pública brasileira

    Directory of Open Access Journals (Sweden)

    Rodrigo S. Bender

    2017-01-01

    Full Text Available ISO/IEC 17025 is an international standard that specifies the general requirements for evaluating the competence of laboratories involved in testing and calibration. This standard brings several benefits to university laboratories, which, thus, seek to obtain the accreditation. However, although cost is one of the main obstacles in this process; this topic has not been sufficiently studied. Since the Universidade Federal de Santa Maria (UFSM supports its laboratories for the implementation of this standard, it was chosen for this article to identify and quantify the accreditation costs of its laboratories that have obtained it or are working toward the goal. An exploratory literature review was carried out, and the data gathered were analyzed qualitatively and quantitatively. This study observed that the costs related to hours worked are linked to staff qualification and that high expenses in equipment and infrastructure occur in laboratories that receive financial resources from external providers.

  6. IEC Newsletter, No. 52/2 (2015)

    International Nuclear Information System (INIS)

    2015-10-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Peer Review of UAE’s Emergency Plans for Barakah NPP; IEM 9: Assessment and Prognosis in Response to a Nuclear or Radiological Emergency; Tabletop exercise simulating marime transport emergency; Establishment of EPR Standards Committee; Annual ConvEx-1c; Advisory Mission to Kuwait on medical aspects of EPR; EPR self-assessment for Arab Member States; Event at Cattenom NPP; Train the Trainers Workshop for first responders in Vienna; Member States Preparedness; Republic of Korea joins RANET — USA registers new capabilities; Workshop on Emergency Radiation Monitoring; #EPR15: International Conference on Global EPR; Recent Events

  7. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  8. Interpretation of MS ISO/ IEC 17020

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2012-01-01

    MS ISO/ IEC 17020 is an international standard which adopted by Malaysian Standard states the requirement criteria for inspection bodies. The author involved in the NDT technical assessment to several NDT companies in Malaysia. The experience in performing NDT assessment activity is explained and discussed. (author)

  9. Non-destructive testing. The current state of standards and qualification and certification for leak testing

    International Nuclear Information System (INIS)

    Tamura, Yoshikazu

    2011-01-01

    Domestic standards of the leak testing are enacted as one of Japan Industrial Standards. The conformity is advanced between these domestic standards and ISO (International Organization for Standardization) standard. ISO9712 (Non-destructive testing-Qualification and certification of personnel) was revised to include the leak testing of qualification and certification in 2005. The preparation working group of qualification and certification for leak testing is planning start aiming at the system in one and a half years. (author)

  10. 42 CFR 493.1469 - Standard: Cytology general supervisor qualifications.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Cytology general supervisor... Nonwaived Testing Laboratories Performing High Complexity Testing § 493.1469 Standard: Cytology general supervisor qualifications. The cytology general supervisor must be qualified to supervise cytology services...

  11. Power system EMC and IEC publication 1000

    International Nuclear Information System (INIS)

    Teichmann, H.

    1997-01-01

    A classification of the principal phenomena causing electromagnetic disturbances has been prepared by the International Electrotechnical Commission (IEC). Electromagnetic compatibility was defined (by the IEC) as 'the ability of a device, equipment or system to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances in that environment'. The classification includes the following phenomena relative to power systems: (1) low-frequency phenomena, (2) radiated low-frequency phenomena, (2) conducted high-frequency phenomena, (3) radiated high-frequency phenomena, and (4) electrostatic discharge phenomena. The structure of the IEC publication 1000 was explained. Parts 1, 2, 3 and 6 of the publication were highlighted. The issues covered in those parts were: (Part 1) general, (Part 2) environment, (Part 3) limits, and (Part 6) generic standards. 6 refs

  12. Progress in IEC 61400-27

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Andresen, Björn; Bech, John

    2012-01-01

    turbines (part 1) and wind power plants (part 2), which are intended for short-term power system stability analyses. WG27 submitted the first CD of Part 1 in December 2012. The CD describes generic wind turbine models and a procedure for validation of wind turbine models. The generic model description......This paper presents the status of the ongoing work in IEC Technical Committee 88 Working Group 27 (TC88 WG27) developing a standard IEC 61400-27 for “Electrical simulation models for wind power generation”. The purpose of this standardization work is to define generic simulation models for wind...... consists of a general model structure intending to cover existing as well as future types of wind turbines, and specific fundamental frequency positive sequence models for the four wind turbine types which are widely used today. The validation procedure can be applied to the generic models specified...

  13. IEEE Std 382-1980: IEEE standard for qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  14. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    International Nuclear Information System (INIS)

    Supanich, M.

    2015-01-01

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists

  15. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Supanich, M. [Rush University Medical Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  16. Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Hwang, In Koo; Lee, Dong Young

    2005-04-01

    This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in the seismic related aspects. Therefore, it is conceived that any equipment or system qualified seismically in accordance with Korean standards should additionally provide technical evidence that it is satisfactory with Russian standards as well. In electromagnetic interference qualification, because Russian standard requires more testing items than the current Korean standard, the additional qualification tests are necessary to meet the Russian requirements. However, these additional test items are based on IEC(International Electrotechnical Commission), therefore it is not a problem to perform those tests in a Korean testing facility

  17. Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joo Hyun; Hwang, In Koo; Lee, Dong Young

    2005-04-15

    This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in the seismic related aspects. Therefore, it is conceived that any equipment or system qualified seismically in accordance with Korean standards should additionally provide technical evidence that it is satisfactory with Russian standards as well. In electromagnetic interference qualification, because Russian standard requires more testing items than the current Korean standard, the additional qualification tests are necessary to meet the Russian requirements. However, these additional test items are based on IEC(International Electrotechnical Commission), therefore it is not a problem to perform those tests in a Korean testing facility.

  18. Information security for energy automation. IEC 62351 Challenges and possible solutions; Informationsicherheit fuer die Energieautomatisierung. IEC 62351 - Herausforderungen und Loesungsansaetze

    Energy Technology Data Exchange (ETDEWEB)

    Knorr, K.; Fries, S. [Sector Corporate Technology, Siemens AG, Muenchen (Germany); Seewald, M.G. [Sector Energy, Siemens AG, Nuernberg (Germany)

    2008-10-06

    Information security has gained tremendous importance for energy automation systems over the last years. New standards like IEC 62351 address this topic and specify technical requirements which have to be met by the vendors. Especially vendors that cover the entire energy automation chain with their product portfolio have to face several new demanding challenges. The authors describe suitable approaches and implementation issues that are derived from selected IEC 62351 requirements following the product lifecycle process. (orig.)

  19. X radiation qualities characterization following the standard IEC 61267 recommendations at the calibration laboratory of IPEN

    International Nuclear Information System (INIS)

    Franciscatto, Priscila Cerutti

    2009-01-01

    This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN. (author)

  20. Using the IEC Standard to Describe Low-Background Detectors-What Can You Expect?

    International Nuclear Information System (INIS)

    Ronald M. Keyser; Sanford Wagner

    1998-01-01

    The new International Electrotechnical Commission (IEC) standard for describing the background makes the specification of the background in a high-purity germanium (HPGe) detector simple, unambiguous, and related to how the detector will be used. Users and manufacturers will finally be speaking the same language on this subject. Because this standard extends the specification of the performance of an HPGe detector, there is little history available for comparison and thus no means of determining a ''good'' value. To develop a history, the background spectrum for 500 low-background HPGe ORTEC detectors were all counted in similar low-background shields. These detectors were in a variety of mechanical cryostat and endcap configurations. The continuum background is a function of energy and detector size/configuration. The peak area for the peak energies listed in the standard is a function of detector size and configuration. The results thus give practical guidance for obtaining the most appropriate low-background detector for a specific measurement problem

  1. Understanding IEC standard wind turbine models using SimPowerSystems

    DEFF Research Database (Denmark)

    Das, Kaushik; Hansen, Anca Daniela; Sørensen, Poul Ejnar

    2016-01-01

    This article describes and exemplifies the IEC 61400-27 generic wind turbine models through an interactive multimedia learning environment - Matlab SimPowerSystems. The article aims help engineers with different backgrounds to get a better understanding of wind turbine dynamics and control...

  2. Qualification of Programmable Electronic System (PES) equipment based on international nuclear I and C standards

    International Nuclear Information System (INIS)

    De Grosbois, J.; Hepburn, G. A.; Olmstead, R.; Goble, W.; Kumar, V.

    2006-01-01

    Nuclear power plants (NPPs) are increasingly faced with the challenge of qualifying procured equipment, sub-components, and systems that contain digital programmed electronics for use in safety-related applications. Referred to as a 'programmable electronic system' (PES), such equipment typically contains both complex logic that is vulnerable to systematic design faults, and low voltage electronics hardware that is subject to random faults. Procured PES products or components are often only commercial grade, yet can offer reliable cost effective alternatives to custom-designed or nuclear qualified equipment, provided they can be shown to meet the quality assurance, functional safety, environmental, and reliability requirements of a particular application. The process of confirming this is referred to as application-specific product qualification (ASPQ) and can be challenging and costly. This paper provides an overview of an approach that has been developed at Atomic Energy Canada Limited (AECL) and successfully applied to PES equipment intended for use in domestic Candu R 6 nuclear power plants and special purpose reactors at Chalk River Laboratories. The approach has evolved over the past decade and has recently been adapted to be consistent with, and take advantage of new standards that are applicable to nuclear safety-related I and C systems. Also discussed are how recognized third-party safety-certifications of PES equipment to International Electrotechnical Commission (IEC) standards, and the assessment methods employed, may be used to reduce ASPQ effort. (authors)

  3. IEEE standard for design qualification of safety systems equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This standard is written to serve as a general standard for qualification of all types of safety systems equipment, mechanical and instrumentation as well as electrical. It also establishes principles and procedures to be followed in preparing specific safety systems equipment standards. Guidance for qualifying specific safety systems equipment may be found in various specific equipment qualification standards that are now available or are being prepared. It is required that safety systems equipment in nuclear power generating stations meet or exceed its performance requirements throughout its installed life. This is accomplished by a disciplined program of design qualification and quality assurance of design, production, installation, maintenance and surveillance. This standard is for the design qualification section of the program only. Design qualification is intended to demonstrate the capability of the equipment design to perform its safety function(s) over the expected range of normal, abnormal, design basis event, post design basis event, and in-service test conditions. Inherent to design qualification is the requirement for demonstration, within limitations afforded by established technical state-of-the-art, that in-service aging throughout the qualified life established for the equipment will not degrade safety systems equipment from its original design condition to the point where it cannot perform its required safety function(s), upon demand. The above requirement reflects the primary role of design qualification to provide reasonable assurance that design- and age-related common failure modes will not occur during performance of safety function(s) under postulated service conditions

  4. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  5. ITIL and ISO/IEC 20000 a practical handbook

    CERN Document Server

    Hernandez, Alex

    2012-01-01

    The purpose of this publication is to provide your organization with a pragmatic approach to effectively implementing service management, incorporating practices from the ITIL framework and the ISO/IEC 20000 standard.

  6. The common information model CIM IEC 61968/61970 and 62325 : a practical introduction to the CIM

    CERN Document Server

    Uslar, Mathias; Rohjans, Sebastian; Trefke, Jörn; Vasquez Gonzalez, Jose Manuel

    2012-01-01

    Within the Smart Grid, the combination of automation equipment, communication technology and IT is crucial. Interoperability of devices and systems can be seen as the key enabler of smart grids. Therefore, international initiatives have been started in order to identify interoperability core standards for Smart Grids.   IEC 62357, the so called Seamless Integration Architecture, is one of these very core standards, which has been identified by recent Smart Grid initiatives and roadmaps to be essential for building and managing intelligent power systems. The Seamless Integration Architecture provides an overview of the interoperability and relations between further standards from IEC TC 57 like the IEC 61970/61968: Common Information Model - CIM.   CIM has proven to be a mature standard for interoperability and engineering; consequently, it is a cornerstone of the IEC Smart Grid Standardization Roadmap. This book provides an overview on how the CIM developed, in which international projects and roadmaps is h...

  7. TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  8. A multi-function IEC 61850 packet generator based on FPGA

    International Nuclear Information System (INIS)

    Wei, Wei; Li, Hong-bin; Cheng, Han-miao

    2016-01-01

    An IEC 61850 packet generator is used to produce IEC 61850-9-2 packets by simulating the merging unit and testing the IEC 61850 digital device. While the existing IEC packet generator can produce ideal digital without any noise, it does not take into account the fact that the merging unit output signal packets will be inevitably superimposed with noise. Since the International Electrical Commission standard of the electronic current transformer specifies the minimum output signal-to-noise ratio of the merging unit to be 30 dB, and the signal superimposed with noise will influence the operation performance of the digital device, it is necessary to design a multi-function IEC 61850-9-2 packet generator for a digital device test. Therefore, in this paper, a multi-function IEC 61850 packet generator has been developed, which not only can output various IEC 61850-9-2 packets, but also can add white Gaussian noise to the signal for digital device testing. By testing three digital electricity meters from different manufacturers, we showed that the error of the digital electricity meter is significantly larger when the signal packet is superimposed with noise. Also when the signal-to-noise ration is 30 dB, the error of one of the meters exceeds the allowed range of the accuracy class. This indicates that the noise testing and the noise setting function of the system has an important role in the testing of a digital device. (paper)

  9. Challenges of equipment qualification using today's standards with emphasis on a class 1E motor program

    International Nuclear Information System (INIS)

    Deaton, K.

    1995-01-01

    This paper describes qualification of new equipment for safety related service in the nuclear power industry in accordance with current industry standards. This topic is presented from the perspective of an original equipment manufacturer J(OEM). Equipment qualification is first discussed in a general way then an example is provided of an electric motor qualification. A review of alternative qualification methods including commercial dedication is included. Potential difficulties with alternative/expedited qualification methods are also discussed

  10. Evaluation of the central libraries information security management at governmental universities located in Tehran, according to the international standard ISO/IEC 27002

    Directory of Open Access Journals (Sweden)

    Milad Malekolkalami

    2014-02-01

    Full Text Available This study assessed the evaluation of information security management status in central Libraries of governmental universities located in Tehran, according to ISO / I.E.C. 27002. Research method applied for the study is descriptive Survey and a questionnaire was used for collecting information. The questionnaire was distributed between the 74 central library managers of governmental universities in Tehran according to the recent list on the website of Ministry of Science, Research and Technology, that includes 39 components based on 11 indicators of the standard ISO/ I.E.C. 27002. Analysis of data has been done by using both descriptive and inferential statistics by Microsoft Excel 2007and SPSS statistical softwares. The results of research showed that the mean for libraries in 11 indexes are as follows: The mean for the first index, Security policy, is 3.91 , in the second index, organization of information security, is 4.23, in the third index, asset security management, is 4.38, in the fourth index, Human Resources Security management, is 4, in the fifth index, physical and environment Security management, is 4.07, in the sixth index, operations management and communications, is 4.15, in the Seventh index, access controls management, is 4.38, in the eighth index, information system acquisition, development and maintenance, is 3.92, in the ninth index, information security incident management, is 3.84, in the tenth index, business continuity management, is 3.46, in the eleventh index, compliance, is 3.69 that match with the standard ISO / IEC. 27002. The results of Research shown that totally mean for standard ISO/I.E.C. 27002 in the field of information security management in the central libraries, is 4 being in a good condition and there is no significant differences between the performance of the Central libraries of the governmental Universities in Tehran, since It is not observed significant difference between them in the field of

  11. Modelling of plug and play interface for energy router based on IEC61850

    Science.gov (United States)

    Shi, Y. F.; Yang, F.; Gan, L.; He, H. L.

    2017-11-01

    Under the background of the “Internet Plus”, as the energy internet infrastructure equipment, energy router will be widely developed. The IEC61850 standard is the only universal standard in the field of power system automation which realizes the standardization of engineering operation of intelligent substation. To eliminate the lack of International unified standard for communication of energy router, this paper proposes to apply IEC61850 to plug and play interface and establishes the plug and play interface information model and information transfer services. This paper provides a research approach for the establishment of energy router communication standards, and promotes the development of energy router.

  12. A primer on the Petri Net Markup Language and ISO/IEC 15909-2

    DEFF Research Database (Denmark)

    Hillah, L. M.; Kindler, Ekkart; Kordon, F.

    2009-01-01

    Standard, defines a transfer format for high-level nets. The transfer format defined in Part 2 of ISO/IEC 15909 is (or is based on) the \\emph{Petri Net Markup Language} (PNML), which was originally introduced as an interchange format for different kinds of Petri nets. In ISO/IEC 15909-2, however...

  13. Standard guide for qualification of measurement methods by a laboratory within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide provides guidance for selecting, validating, and qualifying measurement methods when qualification is required for a specific program. The recommended practices presented in this guide provide a major part of a quality assurance program for the laboratory data (see Fig. 1). Qualification helps to assure that the data produced will meet established requirements. 1.2 The activities intended to assure the quality of analytical laboratory measurement data are diagrammed in Fig. 1. Discussion and guidance related to some of these activities appear in the following sections: Section Selection of Measurement Methods 5 Validation of Measurement Methods 6 Qualification of Measurement Methods 7 Control 8 Personnel Qualification 9 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitati...

  14. Prototype of generic server for wind power plants using IEC 61400-25 standard

    DEFF Research Database (Denmark)

    Olsen, Andreas K.; Ösdil, B.; Poulsen, Bjarne

    2006-01-01

    from interfaces for control and monitoring to a standardized and secure way of handling communication. An analysis focusing on isolating the necessary requirements has been carried out based on the IEC61400-25 in order to create a generic prototype which can be used by WPP vendors. The main...... communications interface of the prototype utilizes web services and the prototype developed is comprised of several independent modules to allow for the possibility of choosing a fully customizable setup by the end user. Configuration of the system needs to be done in a simple way, ensuring a flexible...... and reusable system, where different choices for the system can be added or left out depending on user specifications. From the requirements a prototype with the purpose of examining the key aspects of these definitions has been elaborated....

  15. IEC Newsletter, No. 49, Third Quarter 2014

    International Nuclear Information System (INIS)

    2014-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Spolighting IEC Activities at the 58th IAEA General Conference; • TM on Lessons Learned from Past Emergency Preparedness Review (EPREV) Missions; • Third Full Response Exercise of 2014; • Israel joins RANET; • Launch of Emergency Preparedness Network (EPnet); • IEC Response to Recent Events; Member State Prepaedness; • New Publications Translation; • New USIE Training Video; • The IEC in Numbers

  16. IEC Newsletter, No. 49, Third Quarter 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-12-15

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Spolighting IEC Activities at the 58th IAEA General Conference; • TM on Lessons Learned from Past Emergency Preparedness Review (EPREV) Missions; • Third Full Response Exercise of 2014; • Israel joins RANET; • Launch of Emergency Preparedness Network (EPnet); • IEC Response to Recent Events; Member State Prepaedness; • New Publications Translation; • New USIE Training Video; • The IEC in Numbers.

  17. Evolution of IEC/TC 45 works and its sub-committees from 1960 to 1983

    International Nuclear Information System (INIS)

    Weill, J.

    1983-10-01

    The IEC, founded in 1906, is an independent international standards organization. Its standardization work deals with almost all branches of electrotechnology in the electrotechnical, electronical and data-processing field, covering all applications, as for example telecommunications and nuclear energy. The IEC Central Office is situated in Geneva (Switzerland). The Technical Committee No. 45 was set up in 1960 at the IEC general meeting in New Delhi, with the scope as given in the IEC Directory. Its revised scope is under consideration in the Committee of Action of the IEC and reads: ''To prepare international standards relating to electrical and electronic equipment and systems specific to nuclear applications''. The chart shows the organigram of the Technical Committee which comprises about 75 experts in the nuclear field from about 20 industrial countries. We can see here the standard diagram of a Technical Committee with its Sub-committees and Working Groups. The meetings are held in a member country at the request of its National Committee. One shows the places of the plenary meetings of TC 45 as well as the meetings of its Sub-committees and their Working Groups held till now. The Technical Committee 45 has in addition to its seven Working Groups also two Sub-committees having several further Working Groups of their own. The Sub-committee 45 A ''Reactor Instrumentation''. The Sub-committee 45 B ''Radiation protection instrumentation''. Till now TC 45 has published about 85 standards. Regarding work in preparation, one shows the present and future work within the Technical Committee and its Sub-committees. Impact of works and liaisons is briefly discussed [fr

  18. Certification of boiler safety equipment with ALSPA P320 system, to IEC 61508 standard; Certification des equipements de securite chaudiere avec le systeme ALSPA P320 selon la norme IEC 61508

    Energy Technology Data Exchange (ETDEWEB)

    Dalzon, J.P. [Alstom Power (France)

    2002-02-01

    Safety and environmental protection are major priorities governing Alstom work on control systems (Alspa P320) for power plant applications, especially when potentially dangerous processes like high-power flame boilers (typically rated at 100 to 600 MW) are involved. Here, automatic protection chains are implemented to guard against the risk of serious incident such as explosion and equipment destruction. In this kind of situation, the IEC 61508 standard provides baseline specifications for certification of safety systems. (authors)

  19. Commercial IEC portable neutron source

    International Nuclear Information System (INIS)

    Sved, J.

    1997-01-01

    The inertial electrostatic confinement (IEC) fusion grade plasma devices are being developed as a commercial industrial product by Daimler-Benz Aerospace (DASA), Center Trauen, which has an exclusive license from the University of Illinois (UI) to manufacture the commercial implementation of the Miley et al. IEC inventions. DASA is funding the UI Fusion Studies Laboratory basic IEC research and the intellectual property protection process. The association of the DASA Space Infrastructure division with an apparently unrelated technology has arisen from the perception that IEC technology may benefit from certain aerospace technologies and eventually create a market for space infrastructure services. In addition, DASA Center Trauen has a number of environmental technology businesses

  20. TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Culberson, W. [University of Wisconsin - Madison (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  1. A strategy for implementation of experience based seismic equipment qualification in IEEE and ASME industry standards

    International Nuclear Information System (INIS)

    Adams, T.M.

    1996-01-01

    In the past 20 years, extensive data on the performance of mechanical and electric equipment during actual strong motion earthquakes and seismic qualification tests has been accumulated. Recognizing that an experience based approach provides a technically sound and cost effective method for the seismic qualification of some or certain equipment, the IEEE Nuclear Power Engineering Committee and the ASME Committee on Qualification of Mechanical Equipment established a Special Working Group to investigate the incorporation of experienced based methods into the industry consensus codes and standards currently used in the seismic qualification of Seismic Category Nuclear Power Plant equipment. This paper presents the strategy (course of action) which was developed by the Special Working Group for meeting this objective of incorporation of experience based seismic qualification standards used in the design and seismic qualification of seismic category nuclear power plant equipment. This strategy was recommended to both chartering organizations, the IEEE Nuclear Power Engineering Committee and the ASME Committee on Qualification of Mechanical Equipment for their consideration and implementation. The status of the review and implementation of the Special Working Group's recommended strategy by the sponsoring organization is also discussed

  2. Effective IEC approaches for Asia. IEC evaluation workshop.

    Science.gov (United States)

    1996-02-01

    The UNFPA-supported project on development and distribution of information, education, and communication (IEC) materials in support of improving women's health and status was evaluated at a workshop held in Tokyo in December 13-15, 1995. The 1992-95 cycle of the project was analyzed by experts from Bangladesh, China, India, Indonesia, Malaysia, Nepal, the Philippines, and Vietnam plus three experts from the UNFPA/Country Support Team. The workshop also made it possible for the experts to identify needs as well as effective utilization of existing IEC materials. It was suggested that a nongovernmental organization be established for the distribution and effective use of these materials. The workshop mostly reviewed the print and audiovisual materials. Videos were also evaluated. The materials were found useful for the targeted region. Among other subregional issues it was noted that youth needs were inadequately addressed as they related to sexually transmitted diseases (STDs), unwanted pregnancy, risk of maternal mortality and morbidity, low birth weight, and premature birth. Although the women of the region comprise one-third of the world's population, 70% of the global annual maternal mortality of 500,000 occurs in the subregion. IEC materials should also target adolescents and their support groups. Other needs were also outlined: the expansion of educational opportunities for women, the promotion of employment, the involvement of men, and the training of personnel. The strategies used in the cycle helped strengthen self-reliance through information and experience sharing. The focus on women should be continued with more attention paid to adolescents and young adults, including males. Women's health issues should be expanded to include menopause, reproductive tract infections, STDs, HIV/AIDS prevention, and legal rights including abortion. The production of IEC materials should be identified through research and analysis of existing materials, focus group

  3. Challenges of equipment qualification using today`s standards with emphasis on a class 1E motor program

    Energy Technology Data Exchange (ETDEWEB)

    Deaton, K.

    1995-02-01

    This paper describes qualification of new equipment for safety related service in the nuclear power industry in accordance with current industry standards. This topic is presented from the perspective of an original equipment manufacturer J(OEM). Equipment qualification is first discussed in a general way then an example is provided of an electric motor qualification. A review of alternative qualification methods including commercial dedication is included. Potential difficulties with alternative/expedited qualification methods are also discussed.

  4. Overview, status and outline of the new IEC 61400-27. Electrical simulation models for wind power generation

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Poul [Wiley (John) and Sons, Inc., New York, NY (United States). Journal Dept.; Andresen, Bjoern [Siemens Wind Power (Denmark); Fortmann, Jens [RE-Power Systems AG (Germany); Johansen, Knud [Energinet.dk (Denmark); Pourbeik, Pouyan [EPRI (United States)

    2011-07-01

    This paper presents the ongoing work in Working Group (WG) 27 of IEC Technical Committee (TC) 88 developing a standard IEC 61400-27 for 'Electrical simulation models for wind power generation'. The purpose of the standardization work is to define generic simulation models for wind turbines and wind power plants, which are intended for power systems stability analyses. Thus, the models will be applicable for dynamic simulations of power system events such as faults, loss of generation or loads and switching of lines. The paper presents the actual status of the IEC TC88 WG27 work. Some of the challenges encountered during the process of the development of the standard are described, and expected outcome of the standard is also presented. (orig.)

  5. Reliability Evaluation of Concentrator Photovoltaic Modules per IEC Qualification Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Tamizhmani, Govindasamy

    2012-12-05

    This project is related to the qualification testing of new generation CPV (concentrator photovoltaics) modules at lower testing costs and lower turnaround time. In this project, the first testing program was completed for two CPV manufacturers, the second testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time and the third testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time. Due to their financial situation and restructuring, Amonix (one of the CPV manufacturers) intermittently terminated the test programs.

  6. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  7. Can non-regulators audit Independent Ethic Committees (IEC), and if so, how?

    Science.gov (United States)

    Dent, N J; Sweatman, W J

    A number of guidelines and directives have reinforced the need for a more formalised approach to Independent Ethic Committees (IECs) and support the need to audit IECs. The key elements of an audit of an IEC are reviewed within the context of the European Guidelines for Auditing Independent Ethics Committees published by the European Forum for Good Clinical Practice (EFGCP). Auditing requirements in these recent guidelines and the EU Clinical Trial Directive are discussed as well as the methodology and type of documentation and SOPs that should be present at an audit. It is argued that both inspectorates and independent auditors need to conduct such audits to improve the overall global standard.

  8. IEEE Std 382-1985: IEEE standard for qualification of actuators for power operated valve assemblies with safety-related functions for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of power-driven valve actuators with safety-related functions Part I describes the qualification process. Part II describes the standard qualification cases and their environmental parameters for the usual locations of safety-related equipment in a nuclear generating station. Part III describes the qualification tests outlined in 6.3.3

  9. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    Correa, Eduardo de Lima

    2010-01-01

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  10. IEC60193存在的部分问题及新国标对其的修正%Some Problems which Exist in IEC 60193 and the Amendment by the New National Standard

    Institute of Scientific and Technical Information of China (English)

    徐洪泉; 刘诗琪; 宫让勤; 梁妍

    2012-01-01

    本文在肯定IEC60193的同时,指出了其存在的部分问题,并结合新修订的国家标准对这些问题加以修正,从水轮机公称直径的定义、流道测量偏差要求的表述及空化系数定义等三个方面提出了比较符合中国实际的定义或表述.%This paper affirms the achievements of the IEC 60193, meanwhile, it points out some problems which exist in it, and considering the amendment by the New Chinese National Standard. It puts forward the definition or description which is in accord with actual situation of China from the three aspects of the definition for nominal diameter of the hydraulic turbines, the statement for requirement of the water passage flow measurement deviation and the definition of the cavitation sigma.

  11. Using the IEC standard to describe low-background detectors -- What can you expect?

    International Nuclear Information System (INIS)

    Keyser, R.M.; Wagner, S.

    1998-01-01

    Many measurements for environmental levels of the radioactive content require that the gamma-ray detector be low background, that is, free of any radioactive content. This is, of course, not possible, but the radioactivity in the detector must be reduced to as low a value as possible. The description or specification of the background spectrum necessary to achieve the desired results is needed. The new International Electrotechnical Commission (IEC) standard for describing the background makes the specification of the background in a high-purity germanium (HPGe) detector simple, unambiguous, and related to how the detector will be used. Users and manufacturers will finally be speaking the same language on this subject. Because this standard extends the specification of the performance of an HPGe detector, there is little history available for comparison and thus no means of determining a good value. To develop a history, the background spectrum for 500 low-background HPGe ORTEC detectors were all counted in similar low-background shields. These detectors were in a variety of mechanical cryostat and endcap configurations. The continuum background is a function of energy and detector size/configuration. The peak area for the peak energies listed in the standard is a function of detector size and configuration. The results thus give practical guidance for obtaining the most appropriate low-background detector for a specific measurement problem

  12. IEC Newsletter, No. 50, Fourth Quarter, 2014

    International Nuclear Information System (INIS)

    2014-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (… IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Three Workshops at the Fukushima RANET Capacity Building Centre; Belgium joins RANET; IEC Response to Recent Events; Recent Exercises; Israel conducts National Response Exercise at Soreq; IACRNE: 24th Regular Meeting; Safety Requirements on Emergency Preparedness and Response; NIRS 2014 Workshop on Radiation Emergency Medicine; Member State Preparedness; New Publications and Translations and Forthcoming Events

  13. IEEE Standard for qualification of Class 1E lead storage batteries for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This document describes qualification methods for Class 1E lead storage batteries and racks to be used in nuclear power generating stations outside of primary containment. Qualification required in ANSI/IEEE Std 279-1979 and IEEE Std 308-1978, can be demonstrated by using the procedures provided in this Standard in accordance with IEEE Std 323-1974. Battery sizing, maintenance, capacity testing, installation, charging equipment and consideration of other types batteries are beyond the scope of this Standard

  14. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Klieber, E

    1986-08-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example.

  15. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    International Nuclear Information System (INIS)

    Rassow, J.; Klieber, E.

    1986-01-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example. (orig.) [de

  16. Guidebook for establishing a sustainable and accredited system for qualification and certification of personnel for non-destructive testing

    International Nuclear Information System (INIS)

    2009-01-01

    Non-destructive testing (NDT) methods are used for detection, location and sizing of surface and internal defects (in welds, castings, forging, composite materials, concrete and many more). Various NDT methods are also used in preventive maintenance (nuclear power plants, aircraft, bridges, etc.). NDT methods are essential to the inspection of raw materials and half-finished products. They are applied to finished products and to in-service inspection, as well as for the design and development of new products and for plant life assessment studies. Thus NDT technology contributes significantly to the protection of life, public health and the environment through assurance of the quality and integrity of critical equipment and facilities. It is especially important in the developing Member States where the consequences of failure may be particularly severe, resulting in social, financial and environmental impacts. The IAEA has supported developing Member States for capacity building in utilization of NDT technology by providing experts, equipment, training opportunities and scientific visits. It was recognized early that NDT operator qualification and certification deserved special attention as the Member States began to apply NDT technology to local industrial problems. A series of meetings, workshops and publications have been dedicated to this issue. These efforts have led to a stage of maturity and self-sufficiency in many countries, especially in the field of training and certification of personnel, and in the provision of services to industries. ISO 9712, the international standard for qualification and certification of NDT personnel, has been adopted as the cornerstone for carrying out the training and certification activities. In 2005, a revised version of the standard, ISO 9712:2005, was published. There are some significant differences in this standard from previous editions, particularly in reference to an accreditation standard, ISO/IEC 17024:2003 (2003

  17. IEC ready for turnaround in nuclear industry

    International Nuclear Information System (INIS)

    Schomberg, R.; Corte, E.; Thompson, I.

    2005-01-01

    The activity of IEC Technical Committee (TC) 45 (Nuclear Instrumentation) in conditions of turnaround in nuclear industry is considered. TC 45's main task is to lay down a comprehensive strategy for itself and its two subcommittees as well as to improve the relevance of the nuclear safety standards. Subcommittee 45A develops standards that apply to the electronic and electrical functions and associated systems and equipment used in the instrumentation and control systems of nuclear energy generation facilities. Subcommittee 45B develops and issues standards covering all aspects of instrumentation associated with radiation protection including radiation detectors, radiation monitoring, dosimetry and radiology [ru

  18. Consistent integrated automation. Optimized power plant control by means of IEC 61850; Durchgaengig automatisieren. Optimierte Kraftwerksleittechnik durch die Norm IEC 61850

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany). Geschaeftsbereich Power Generation

    2007-07-01

    Today's power plants are highly automated. All subsystems of large thermal power plants can be controlled from a central control room. The electrical systems are an important part. In future the new standard IEC 61850 will improve the integration of electrical systems into automation of power plants supporting the reduction of operation and maintenance cost. (orig.)

  19. Developing IEC prototypes for adolescents. IEC workshop.

    Science.gov (United States)

    1997-01-01

    Participants of the IEC Workshop for the Production of OHP Material on Reproductive Health for Adolescents and Young Adults held November 25-30 in Japan developed innovative, visually appealing overhead projector (OHP) transparencies to serve as prototype information, education, and communication (IEC) materials for the Asian Region. The materials cover a wide range of topics from early marriage to unwanted pregnancy. This paper briefly describes the prototypes. One group focused upon early marriage, an issue of considerable importance to the health and welfare of young women in countries such as Bhutan, India, and Nepal. Participants from China, Laos, Malaysia, and Thailand focused upon the issue of gender equality, while a third group developed OHP material to teach a range of issues related to young people's sexual and reproductive health. Finally, the fourth group, drawn from Indonesia, the Philippines, and Vietnam, focused upon the topic of menstruation with a prototype targeted to boys and girls aged 9-14 years. Boys were included to foster their understanding of menstruation as a natural phenomenon.

  20. Type tests performed on a personnel dosimetry system according to IEC 61066

    International Nuclear Information System (INIS)

    Castillo, Romel; Huamanlazo, Paula; Rojas, Enrique

    2015-01-01

    In this study, the verification of the Harshaw 6600 Plus TLD personal dosimetry system was made using the method of the IEC-61066 type tests and the recommendations of the ISO 4037 standards. For this purpose, five dosimeters were irradiated over a water phantom using an irradiator with a 137 Cs source; five dosimeters as control were also used. The evaluated parameters were homogeneity, detection limit, residual reading, linearity, reproducibility, droppings and temperature and humidity variations. The obtained results show that the Harshaw 6600 TLD dosimetric system fulfills the IEC 61066 criteria. (author)

  1. Determination of the detective quantum efficiency (DQE) of CMOS/CsI imaging detectors following the novel IEC 62220-1-1:2015 International Standard

    International Nuclear Information System (INIS)

    Michail, C.; Valais, I.; Martini, N.; Koukou, V.; Kalyvas, N.; Bakas, A.; Kandarakis, I.; Fountos, G.

    2016-01-01

    The purpose of the present study was to determine the Detective Quantum Efficiency (DQE) of CMOS imaging detectors, coupled to structured CsI:Tl and Gd_2O_2S:Tb scintillating screens, following the new IEC 62220-1-1:2015 International Standard. DQE was assessed after the experimental determination of the Modulation Transfer Function (MTF) and the Normalized Noise Power Spectrum (NNPS) in the general radiography energy range. Two CMOS sensors were used; one with a pixel size of 22.5 μmcoupled to a columnar CsI:Tl scintillator screen with thickness of 490 μm, which was placed in direct contact with the optical sensor and one with a pixel size of 74.8 μmcoupled to a 200 μmcolumnar CsI:Tl scintillator screen. The MTF was measured using the slanted-edge method (following both the IEC 62220-1:2003 and IEC 62220-1-1:2015 methods) while NNPS was determined by 2D Fourier transforming uniformly exposed images. Both parameters were assessed by irradiation under the RQA-3 and RQA-5 (IEC 62220-1-1:2015) beam qualities. The detector response functions were linear for the exposure ranges under investigation. MTFs calculated following the 62220-1:2003 protocol, were found in all cases overestimated in the higher frequency range (spatial frequencies higher than 2 cycles/mm). DQE values, determined with the IEC 62220-1:2003 method, were also found overestimated (spatial frequencies higher than 2 cycles/mm), due to the influence of both MTF and NNPS. The influence of both additive and multiplicative lag effects were found below 0.005, insuring that lag contributes less than 0.5% of the effective exposure. - Highlights: • DQE was measured with the novel 62220-1-1:2015 protocol and compared to 62220-1:2003. • Two CMOS sensors were evaluated. • DQE of the 62220-1:2003 was overestimated due to the addition of noise when averaging MTFs.

  2. IEC Newsletter, No. 48, Second Quarter 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-09-15

    The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Competent Authorities Meeting; • ConvEx-1b Exercise in May 2014; • ConvEx-2a Exercise in April 2014; • IAEA Participates in First ConvEx-2e Exercise; • Second Full Response Mode Exercise of 2014; • New Interactive Learning Tool on INES; • INES Technical Meeting; • Participation in the RAD 2014 Conference; • Member State Preparedness; • Pilot Workshop for the Optimization of National Radiation Emergency Plans; • IEC Response to Recent Events; • China and Switzerland Join RANET; Japan Registers in New Functional Area; • Workshop on Radiation Monitoring; • New Publication Translation; • New USIE Feature: USIE Connect; • Twitter Milestone; • IEC News; • IEC Launches New Website.

  3. IEC Newsletter, No. 48, Second Quarter 2014

    International Nuclear Information System (INIS)

    2014-09-01

    The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Competent Authorities Meeting; • ConvEx-1b Exercise in May 2014; • ConvEx-2a Exercise in April 2014; • IAEA Participates in First ConvEx-2e Exercise; • Second Full Response Mode Exercise of 2014; • New Interactive Learning Tool on INES; • INES Technical Meeting; • Participation in the RAD 2014 Conference; • Member State Preparedness; • Pilot Workshop for the Optimization of National Radiation Emergency Plans; • IEC Response to Recent Events; • China and Switzerland Join RANET; Japan Registers in New Functional Area; • Workshop on Radiation Monitoring; • New Publication Translation; • New USIE Feature: USIE Connect; • Twitter Milestone; • IEC News; • IEC Launches New Website

  4. Implementing IEC 61850-7-420 DER Logical Nodes in a single board

    Directory of Open Access Journals (Sweden)

    Anderson Salazar-Zuluaga

    2017-09-01

    Full Text Available This article discusses the implementation of a variety of logical nodes (LNs of power generation systems based on distributed energy resources (DER in a single board computer (SBC. The SBC allows for the acquisition and encapsulation of analog signals from a photovoltaic (PV array with batteries, based on the IEC 61850-7-420 standard. To achieve this, an SBC integrated with an analog-digital conversion card (ADC enables to read the system’s analog values. The SBC communicates with the ADC card to encapsulate the collected data in the IEC 61850 data object by using the corresponding logical node (LN. An open license library was used to create the IEC 61850 server inside the SBC and the driver of the ADC card manufacturer to communicate both cards. This work aims to develop LNs for DERs in such way that manufacturers of power generation technologies based on renewable sources (such as the sun and/or the wind implement Intelligent Electronic Devices (IED and controllers in accordance with the scope of the standard for these logical nodes (LNs. Finally, the communication testing of the implementation and the results obtained are presented.

  5. ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation.

    Science.gov (United States)

    Dimopoulou, H A; Theodoridis, T; Galea, V; Christopoulou-Cokkinou, V; Spyridaki, M-H E; Georgakopoulos, C G

    2007-01-01

    The Sysmex R-500 (R-500) Hematology Analyzer is a bench-top system appropriate for the analysis of limited batches of blood samples. The R-500 provides percentage proportional (RET%), absolute reticulocyte (RET#), and absolute red blood cell (RBC#) counts. The system was validated at the Doping Control Laboratory of Athens, according to the International Committee for Standardization in Hematology, International Standards Organization (ISO/IEC) 17025, and World Antidoping Agency (WADA) specifications. The instrument calibration was performed according to the manufacturer and validation parameters comprised linearity, precision, uncertainty (intermediate and long-term precision), comparability, effect of drift, carryover, stability, and accuracy. The linearity and the comparability studies for RET#, RET%, and RBC# were expressed in regression factors (R2) and coefficients of correlation [r(x, y)], respectively. For the precision studies, the coefficients of variation for RET#, RET%, and RBC# were 9.49%, 9.83%, and ISO/IEC 17025 and WADA specifications.

  6. Auto-Mapping and Configuration Method of IEC 61850 Information Model Based on OPC UA

    Directory of Open Access Journals (Sweden)

    In-Jae Shin

    2016-11-01

    Full Text Available The open-platform communication (OPC unified architecture (UA (IEC62541 is introduced as a key technology for realizing a variety of smart grid (SG use cases enabling relevant automation and control tasks. The OPC UA can expand interoperability between power systems. The top-level SG management platform needs independent middleware to transparently manage the power information technology (IT systems, including the IEC 61850. To expand interoperability between the power system for a large number of stakeholders and various standards, this paper focuses on the IEC 61850 for the digital substation. In this paper, we propose the interconnection method to integrate communication with OPC UA and convert OPC UA AddressSpace using system configuration description language (SCL of IEC 61850. We implemented the mapping process for the verification of the interconnection method. The interconnection method in this paper can expand interoperability between power systems for OPC UA integration for various data structures in the smart grid.

  7. Inertial Electrostatic Confinement (IEC) devices

    International Nuclear Information System (INIS)

    Nebel, R.A.; Turner, L.; Tiouririne, T.N.; Barnes, D.C.; Nystrom, W.D.; Bussard, R.W.; Miley, G.H.; Javedani, J.; Yamamoto, Y.

    1994-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P. T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2 * 10 10 neutrons/sec. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. Atomic physics effects strongly influence the performance of all of these systems. Important atomic effects include elastic scattering, ionization, excitation, and charge exchange. This paper discusses how an IEC system is influenced by these effects and how to design around them. Theoretical modeling and experimental results are presented

  8. Rational Calibration of Four IEC 61400-1 Extreme External Conditions

    DEFF Research Database (Denmark)

    Larsen, Gunner Chr.; Hansen, Kurt Schaldemose

    2008-01-01

    Based on a set of asymptotic statistical models on closed form this paper presents a rational and consistent calibration of four extreme external conditions defined in the International Electrotechnical Commission (IEC) 61400-1 standard: extreme operating gust, extreme wind shear, extreme coheren...... and proposed specifications of the magnitudes of the extreme external wind conditions are highlighted and discussed using an illustrative example based on two selected terrain types. Copyright © 2008 John Wiley & Sons, Ltd....... gust with direction change and extreme wind direction change. These four extreme external conditions are used in the definition of six of the IEC 61400-1 ultimate load cases. The statistical models are based on simple and easily accessible mean wind speed and turbulence characteristics...

  9. Comparison of ANSI, IEC and CSA standards durability requirements on station-type metal oxide surge arresters for EHV power systems

    International Nuclear Information System (INIS)

    Hamel, A.; St-Jean, G.

    1992-01-01

    This paper presents an analysis of stresses applied to two actual types of station class surge arresters of the same voltage rating when tested for durability as prescribed by American (ANSI) International (IEC) and Canadian (CSA) standards for 315 kV and 734 kV power systems. The analysis which is made with an experimentally validated arrester model, reveals that the IEC duty cycle test is the most severe of all. In fact it can bring the varistors of an actual station-type arrester to a peak temperature of 129 degrees C, which leaves a margin of only 46 degrees C to its thermal stability limit at maximum continuous operating voltage (MCOV). Another actual arrester using lesser V-I-T varistor characteristics but larger varistor volume and better heat transfer from inside to outside the arrester, produces 103 degrees C which corresponds to a slightly better temperature margin of 49 degrees C. It is observed that even when using the lower performance V-I-T characteristics of the latter arrester, a thin-wall arrester housing design can improve heat transfer to a point where the margin improves to 101 degrees C on a hypothetical arrester

  10. Improving the quality control program for patient dose calibrator according to IEC 60580

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque

    2013-01-01

    The objective of this work was to improve the program quality control of this equipment based on the International Standard IEC 60580 - Medical electrical equipment - Dose area product meters . The initial program was established following the recommendations of IEC 61674 quoting dosimeters with ionization chambers and / or semiconductor detectors used in diagnostic X-ray image, however, the IEC 60580 is referred specifically to gauges and KAP (kerma-area product) presents additional tests. Tests included: intrinsic relative error, repeatability, scanning resolution, settling time, restarting, float values, response time and spatial uniformity of response. As a rule, all measurements are within the range characteristic of equipment performance. Thus, the PDC (Patient Dose Calibrator) again shows a device with excellent functionality and reliability in characterization tests carried out to quality control as( for the test in clinical PKA meters

  11. IEC planning: eight state-of-the-art principles.

    Science.gov (United States)

    Middleton, J

    1983-12-01

    Considerable experience and research has been accumulated in the last 20 years on the ways in which information/education/communication (IEC) programs can be effectively designed, implemented, and evaluated. Possibly more effort has focused on population and family planning IEC than on any other sectoral program of development communication. Several principles have emerged which, taken together, define the state of the art in the field. These principles provide a framework of experience which can guide the development of comprehensive IEC programs. They include: policy and resource assessment; audience analysis; strategy design; message research and pretesting; participation and feedback; management; evaluation; and collaboration. The nature of the national policy base for population and family planning programs will determine the goals and approaches of the IEC program. Strong policies of limitation on popultion growth lead to equally strong and pervasive IEC efforts designed to directly affect contraceptive behavior. Assessment of existing policy is an essential aspect of the design of an effective IEC program. Policies establish the rationale and boundaries for action. Population and family planning programs are concerned with some of the most intimate human behavior. Consequently, structured and sensitive audience analysis has become an integral part of the design of IEC programs. The design of communication strategy requires clearly stated objectives. Principles of human learning are used to structure information appropriately. Message research and pretesting have become integral components of the strategy design process. Small scale research on specific objectives is necessary to establish the basis for message design. Audience participation and feedback in remaining phases of program development and implementation are important. The management of an IEC program requires a specific combination of planning, flexibility, and creativity. Evaluation of program

  12. The CMMI Product Suite and International Standards

    Science.gov (United States)

    2006-07-01

    standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for

  13. Experimental comparison of the different methods for seismic qualification of electrical cabinets

    International Nuclear Information System (INIS)

    Buland, P.; Gauthier, G.; Simon, D.

    1993-01-01

    This paper presents the results of an experimental seismic study performed on a cabinet equipped with 96 acceleration sensitive relays located in four racks. The aim of this study is to verify the validity of the seismic qualification method proposed in the IEC 980 standard. The cabinet was primarily tested on a shaking table and the relay chatter was monitored. The interactions between the racks and the cabinet frame induce shocks which were correlated with some of the contact openings. The racks were afterwards tested individually with the accelerations recorded during the cabinet test. A comparison of relay chatter was performed for both test phases. An important reduction of relay chatter was noticed during the racks test. This is due to the fact that it is not possible to fully represent on shaking table the complex vibration environment (shocks) sustained by a rack in a cabinet

  14. IEEE Std 600: IEEE trial-use standard requirements for organizations that conduct qualification testing of safety systems equipment for use in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The purpose of this standard is to provide requirements for establishing a program for conducting qualification tests of safety systems equipment used in nuclear power generating stations. Compliance with the requirements of this standard does not assure the adequacy of the qualification tests performed. This standard applies to organizations that conduct qualification tests on equipment that has a definable safety function and is an identifiable part of a safety system for use in nuclear power generating stations. It requires a technical program, a quality assurance program, and a demonstrated ability to meet specified technical requirements. It does not apply to materials tests, production tests, normal performance testing, qualification by analysis, qualification by operating experience, or reliability tests such as diesel-generator multiple start tests. The intent of this standard is to achieve greater consistency, reliability, and reproducibility of test results and to provide adequate control of qualification testing of safety systems equipment

  15. Architectural constraints in IEC 61508: Do they have the intended effect?

    International Nuclear Information System (INIS)

    Lundteigen, Mary Ann; Rausand, Marvin

    2009-01-01

    The standards IEC 61508 and IEC 61511 employ architectural constraints to avoid that quantitative assessments alone are used to determine the hardware layout of safety instrumented systems (SIS). This article discusses the role of the architectural constraints, and particularly the safe failure fraction (SFF) as a design parameter to determine the hardware fault tolerance (HFT) and the redundancy level for SIS. The discussion is based on examples from the offshore oil and gas industry, but should be relevant for all applications of SIS. The article concludes that architectural constraints may be required to compensate for systematic failures, but the architectural constraints should not be determined based on the SFF. The SFF is considered to be an unnecessary concept

  16. ESCC standards, evaluation and qualification of optical fiber connectors for space application

    Science.gov (United States)

    Taugwalder, Frédéric

    2017-11-01

    Optical fiber connectors have been used for the past fifteen years in space application. Reviewing the heritage left from past and current mission, the status of ESCC standards for these components and assemblies will help future use of fiber in space applications. In the frame of the ESA ECI program, Diamond has evaluated and is currently qualifying according to ESCC standards the AVIM and Mini-AVIM connectors. The configuration retained to qualify the connector sets is using a polarization maintaining fiber at 1550nm with a loose tube in PEEK as cable structure. The evaluation has been used to step-stress specific characteristics of the optical fiber connectors with a particular aim at possible failure modes to establish a safety factor for the qualification. The evaluation results presented can be used on a case by case to evaluate special applications that would require to extend the specification. The qualification components can be extended further and a structure for assemblies is proposed in order to simplify fiber optics implementation in space projects.

  17. New way of demonstrating the competence of a laboratory measuring radionuclides - The international draft standard ISO/IEC DIS 17025

    International Nuclear Information System (INIS)

    Palsson, S.E.

    1999-01-01

    In recent years there has been increased interest, and even need, amongst laboratories performing measurements of radionuclides to obtain accreditation. It has been discussed how this could be achieved with maximum flexibility for the laboratories and with minimum effort. The issuing of a new draft international standard, the ISO/IEC DIS 17025, created speculations whether it could offer a new and better way for laboratories to obtain accreditation. It was decided within the NKS/BOK-1.1 project to explore possible options for obtaining accreditation and what possibilities the new standard could offer. The benefits of computerised document control systems were also explored. The results were reported at the 12th Annual Meeting of the Nordic Society for Radiation Protection, 23-27 August 1999. Since then the final version of the standard has been published. The voting will continue until November 16th 1999 and is not clear at present whether the standard will be accepted or not. The original version of this paper was updated to reflect these recent developments. (au)

  18. Developing IEC strategies for population programmes.

    Science.gov (United States)

    Cohen, S I

    1993-01-01

    The thrust of this article is to define terms of IEC, IEC strategies, the stepwise planning process for IEC, data requirements, the ideational change process, and the need for situational and institutional analysis. A chart provided an at-a-glance perspective on the 11 steps in IEC strategic planning for as many specific target groups as needed. The steps are to state the goals, select and prioritize the target audience, describe the target audience,, determine the IEC activities, outline appropriate messages, identify communication channels, identify managerial and organizational strategies, calculate the amount of resources required, identify a realistic time frame, and evaluate critical factors and obstacles. IEC goals are to contribute to solving a problem or supporting an issue, which involved attitudinal and/or behavioral changes. Many strategies are possible. The common weaknesses are the lack of priorities, the view of targets as a mass audience, a lack in support for population strategies, a lack of integration with family planning or specific population sectors, a lack of integration of up-to-data research findings on population programs, vague or difficult-to-measure objectives, reliance on printed media, and sporadic assessment of personnel needs. THe levels of strategy are identified as follows: 1) national and multisectoral, 2) national and sectoral specific, and 3) project specific. Traditional sociocultural research and KAP surveys are not sufficient to provide an understanding of the target audience. There must be an understanding of the stages of individual change: unaware, aware, concerned, information seeking, learning, motivated to change, initial behavior change, sustained behavior change, and adoption or refusal of behavior change. Beliefs must be distinguished from attitudes in measurement. Changes in beliefs may involve correction of misinformation; attitude change requires a motivational approach. Behavior may be determined by other

  19. QUALIFICATIONS FRAMEWORK DEVELOPMENT AND QUALIFICATIONS RATING IN THE LAND MANAGEMENT SPHERE

    Directory of Open Access Journals (Sweden)

    A. A. Myrasheva

    2014-01-01

    Full Text Available The aim of the research is to observe the existing approaches to qualifications framework development in the sphere of land management, cadastres and real estate management, as well as the qualifications framework adaptation to European system. The relevance of the issue is related to the specific professional and institutional problems facing Russian educational establishments engaged in personnel training in the given sphere. The authors demonstrate the qualifications framework development in the land management sector regarding it as a key mechanism of educational mobility and the router for knowledge acquisition and updates. The qualifications framework is referred to as a systematic and structured description of recognized qualifications. The accepted worldwide methodology of organizing the educational process and quality control system is given. The emphasis is on the need to comply the qualifications framework with the Russian State Educational Standards.

  20. Effectiveness of Information, Education and Communication (IEC) on ...

    African Journals Online (AJOL)

    IEC) on the public acceptability of unsafe abortion solution options of contraception, family life education including sex education and liberalization of abortion laws. Our aim was to use IEC to improve public acceptability of the recommended ...

  1. IEEE Std 535-1986: IEEE standard for qualification of Class 1E lead storage batteries for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This document describes qualification methods for Class 1E lead storage batteries and racks to be used in nuclear power generating stations outside of primary containment. Qualification required in ANSI/IEEE Std 308-1980 can be demonstrated by using the procedures provided in this standard in accordance with ANSI/IEEE Std 323-1983. Battery sizing, maintenance, capacity testing, installation, charging equipment, and consideration of other type batteries are beyond the scope of this standard

  2. Application of operating experience in environmental qualification program

    International Nuclear Information System (INIS)

    Lee, S.Y.; Wise, R.

    2000-01-01

    Environmental qualification (EQ) of equipment related to nuclear safety has been carried out in the nuclear community since the 70's. It started with electrical equipment and then expanded to include mechanical equipment. During this evolutionary process, the methods used for EQ have gone through a long period of refinement and clarification. Prior to 1971, qualification for equipment in licensed nuclear power plants was based on the use of electrical components of commonly accepted high industrial quality without the benefit of specific environmental qualification standards. Between 1971 and 1974, most plants used the criteria of IEEE Standard 323-1971 as the basis for demonstrating qualification. Also during this period related 'daughter' standards, mainly by IEEE, became available which addressed qualification for specific equipment items. After July 1974, plants were required to meet the more comprehensive guidelines specified in IEEE Standard 323-1974 and the related 'daughter' standards. IEEE Standard 323-1974 later evolved into IEEE Standard 323-1983. For nuclear power plants built in Ontario during the 70's, i.e. Pickering B and Bruce B, has included the environmental qualification requirements in their respective nuclear safety design guides. It is now recognized that they are not up to the current EQ standards. Darlington, constructed during the 80's, implemented the environmental qualification program in its project. An Environmental Qualification (EQ) Program is now under way in Ontario Power Generation (OPG) to formally implement the Environmental Qualification for Bruce B, Pickering B, and Pickering A and to preserve the Qualification for Darlington G.S. This paper makes a thorough a review of the standard methods used in the past by utilities for environmental qualification. These methods include type testing, analysis, and operating experience. Both type testing and analysis have been clearly defined in standards listed in References [2] to [6] and

  3. Control and management of distribution system with integrated DERs via IEC 61850 based communication

    Directory of Open Access Journals (Sweden)

    Ikbal Ali

    2017-06-01

    Full Text Available Distributed Energy Resources (DERs are being increasingly integrated in the distribution systems and resulting in complex power flow scenarios. In such cases, effective control, management and protection of distribution systems becomes highly challenging. Standardized and interoperable communication in distribution systems has the potential to deal with such challenges to achieve higher energy efficiency and reliability. Ed. 2 of IEC 61850 standards, for utility automation, standardizing the exchange of data among different substations, DERs, control centers, PMUs and PDCs. This paper demonstrates the modelling of information and services needed for control, management and protection of distribution systems with integrated DERs. This paper has used IP tunnels and/or mapping over IP layer for transferring IEC 61850 messages, such as sample values (SVs and GOOSE (Generic Object Oriented Substation Event, over distribution system Wide Area Network (WAN. Finally performance of the proposed communication configurations for different applications is analyzed by calculating End-to-End (ETE delay, throughput and jitter.

  4. Standards and guidelines applicable for the validation of programmable automation systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.

    1993-02-01

    The validation of programmable automation system for an application important to safety in a nuclear power plant requires a comprehensive view about the system quality and reliability. One central point is to get assured that proper international guidelines and standards have been followed in the design, construction and maintenance of the system. The study was directed to locate international standards and guidelines which can support the validation of programmable systems and to evaluate their applicability for the validation of systems on different levels of requirement during their life cycle. The publication reviews the most important international standards (IAEA, ISO, IEC, IEEE) and their basic principles both for system and application program. Several nuclear standards, which have drawn the main attention, and some general programmable automation standards have been examined. In addition one practical automation system has been examined in order to find essential questions. Based on these studies a set of important items for the qualification have been identified

  5. IEEE Std 535-1979: IEEE standard for qualification of Class 1E lead storage batteries for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This document describes qualification methods for Class 1E lead storage batteries and racks to be used in nuclear power generating stations outside of primary containment. Qualification required in ANSI/IEEE Std 279-1971 and IEE Std 308-1978, can be demonstrated by using the procedures provided in this standard in accordance with IEEE Std 323-1974. Battery sizing, maintenance, capacity testing, installation, charging equipment and consideration of other type batteries are beyond the scope of this standard

  6. Establishing the Isotope Hydrology Laboratory in accordance with ISO/IEC 17025:2005 standard

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Dinh Thi Bich Lieu; Vo Thi Tuong Hanh

    2013-01-01

    The ISO/IEC 17025:2005 General requirements for the competence calibration laboratories is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technical , management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed a quality management system in accordance with ISO / IEC 17025:2005, in which the laboratory quality manual has been developed. It describes the laboratory management system , scope of activities related to quality assurance of 13 major ions and tritium content measurement services in water samples. Under quality management system, there are management and technical procedures, analysis procedures, work instructions, technical documentation, file and form system. These documents define the roles, responsibilities, powers, detailed instructions for applying and maintaining effective quality management system. Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO 17025:2005 with VILAS 670 accreditation code. Scope of recognition is analyzed 14 parameters: F - , Cl - , NO 2 - , NO 3 - , Br - , PO 4 3- , SO 4 2- , Li + , Na + , NH 4 + , K + , Mg 2+ , Ca 2+ and 3 H in water by ion chromatography and liquid scintillator counting method. (author)

  7. Laws and ordinances on electric arc protection. Electric arc protection of electric plants; Gesetze und Verordnungen zur Stoerlichtbogensicherheit. Stoerlichtbogensicherheit von elektrischen Betriebsstaetten

    Energy Technology Data Exchange (ETDEWEB)

    Bernards, Stefan; Buenger, Stefan; Grote, Martin [Fritz Driescher KG - Spezialfabrik fuer Elektrizitaetswerksbedarf GmbH und Co., Wegberg (Germany); Boettcher, Lutz-Michael [Ingenieurbuero Boettcher-Consult, Schulzendorf (Germany); Weck, Karl-Heinz [Forschungsgemeinschaft fuer Elektrische Anlagen und Stromwirtschaft (FGH e.V.), Mannheim (Germany)

    2011-02-28

    With the publication of the new standards IEC 62271-200/VDE 0671 part 200-2003: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV, and IEC 62271-202/VDE 0671 part 202-2007: High voltage/low voltage prefabricated substations and their revision, the fundamentals of arc protection qualification of plants and stations were redefined with a view to personnel protection. In the case of new transformer stations, the application of these standards is state of the art. The publications and the application of the new standards for staff protection, plant protection and object protection via electric arc qualification has raised questions concerning the safety of older plants and stations, modernization, reconstruction, enhancement, maintenance, and the re-use of used stations and plants.

  8. Inertial electrostatic confinement I(IEC) neutron sources

    International Nuclear Information System (INIS)

    Nebel, R.A.; Barnes, D.C.; Caramana, E.J.; Janssen, R.D.; Nystrom, W.D.; Tiouririne, T.N.; Trent, B.C.; Miley, G.H.; Javedani, J.

    1995-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P.T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2*10 [10]. neutrons/sec in steady state. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. This paper discusses the IEC concept and how it can be adapted to a steady-state assaying source and an intense pulsed neutron source. Theoretical modeling and experimental results are presented

  9. Environmental qualification program for new designs

    International Nuclear Information System (INIS)

    Doerffer, K.

    2007-01-01

    Qualification of nuclear power plant equipment and components important to safety (ITS) is an integral part of the design process. The qualification methodology differs based on the severity of service conditions (operational and ambient), to which the ITS equipment is exposed. In Canada, the licensing requirements for environmental qualification for new designs are governed by the Canadian Standard Association (CSA) standard, N290.13-2005 titled 'Environmental Qualification of Equipment for CANDU Nuclear Power Plants' and the pre-consultation draft, 'Requirements for Design of Nuclear Power Plants'(DRD), issued for trial use by the Canadian Nuclear Safety Commission (CNSC) in March 2005. This paper will describe AECL's current Environmental Qualification program developed to comply with the above licensing requirements as applied to new designs. The focus will be given to qualification of ITS systems structures and components (SSC) to harsh conditions occurring due to the Design Basis Accidents (DBA). (author)

  10. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  11. Standards update -- 1995

    Energy Technology Data Exchange (ETDEWEB)

    Mason, J.D.

    1995-12-31

    What a year this has been! Not since 1986, when SGML was being finished, has there been so much activity in the SGML world. In ISO, there are new standards being completed and old ones (some of which are not really all that old) being revised. As you`ll be hearing, there is lots of SGML activity in the applications world--particularly on the Internet--and that`s causing other kinds of standards activity. WG8 divides its work into five ``Rapporteur Groups`` (or ``RGs``) for DSSSL, Font Description and Interchange, SGML, SPDL, and Hypermedia Languages. Since interest is in DSSSL, SGML, and Hypermedia Languages, the author only mentions that the other groups have been active, too. The Fronts group has been doing amendments to its standards, ISO/IEC 9541 and ISO/IEC 10036. The Fronts groups has been active in providing support for ISO/IEC 10646, the massive character coding standard that has drawn a lot of attention in the SGML world. The SPDL group has at long last finished its standard, the Standard Page Description Language (ISO/IEC 10180) and is about to publish it. More detailed discussions are given for activity in SGML, DSSSL, and Hypermedia Languages.

  12. Basic Characteristics of IEC Flickermeter Processing

    Directory of Open Access Journals (Sweden)

    Jarosław Majchrzak

    2012-01-01

    . This paper presents the results of the numerical simulations that reconstruct the processing of flickermeter in frequency domain. With the use of standard test signals, the characteristics of flickermeter were determined for the case of amplitude modulation of input signal, frequency modulation of input signal, and for input signal with interharmonic component. For the needs of simulative research, elements of standard IEC flickermeter signal chain as well as test signal source and tools for acquisition, archiving, and presentation of the obtained results were modeled. The results were presented with a set of charts, and the specific fragments of the charts were pointed out and commented on. Some examples of the influence of input signal’s bandwidth limitation on the flickermeter measurement result were presented for the case of AM and FM modulation. In addition, the diagrams that enable the evaluation of flickermeter’s linearity were also presented.

  13. Towards a systematic format for (seismic) equipment qualification standards

    International Nuclear Information System (INIS)

    Smith, P.D.

    1982-01-01

    As part of technical assistance to the US Nuclear Regulatory Commission (NRC, 1), a systematic format for seismic equipment qualification (EQ) was initiated. This format consists of thirty issues associated with seismic EQ. Each issue was considered as a Category of Possible Seismic EQ Requirements and Criteria. That is, seismic EQ standards might be (but presently are not formulated in terms of requirements and criteria that address each of the thirty issues. Each of the thirty issues was ranked and a minimum set identified. The current requirements in existing NRC and national standards were also evaluated against this common set of issues, and they were estimated to score 60 out of 100 overall. It is believed that the systematic format exhibited in this paper can be of assistance in obtaining a broader and more complete perspective on seismic EQ issues. This format (but especially the technique) may also be of interest in non-seismic EQ since many of the issues are common

  14. Validation of Generic Models for Variable Speed Operation Wind Turbines Following the Recent Guidelines Issued by IEC 61400-27

    Directory of Open Access Journals (Sweden)

    Andrés Honrubia-Escribano

    2016-12-01

    Full Text Available Considerable efforts are currently being made by several international working groups focused on the development of generic, also known as simplified or standard, wind turbine models for power system stability studies. In this sense, the first edition of International Electrotechnical Commission (IEC 61400-27-1, which defines generic dynamic simulation models for wind turbines, was published in February 2015. Nevertheless, the correlations of the IEC generic models with respect to specific wind turbine manufacturer models are required by the wind power industry to validate the accuracy and corresponding usability of these standard models. The present work conducts the validation of the two topologies of variable speed wind turbines that present not only the largest market share, but also the most technological advances. Specifically, the doubly-fed induction machine and the full-scale converter (FSC topology are modeled based on the IEC 61400-27-1 guidelines. The models are simulated for a wide range of voltage dips with different characteristics and wind turbine operating conditions. The simulated response of the IEC generic model is compared to the corresponding simplified model of a wind turbine manufacturer, showing a good correlation in most cases. Validation error sources are analyzed in detail, as well. In addition, this paper reviews in detail the previous work done in this field. Results suggest that wind turbine manufacturers are able to adjust the IEC generic models to represent the behavior of their specific wind turbines for power system stability analysis.

  15. Critical issues for implementation of the standard NBR ISO/IEC 17025:2005 in Testing and Calibration Laboratory: case study at a public institution

    International Nuclear Information System (INIS)

    Castro, Denise Confar Carvalho de

    2013-01-01

    The public institution aims to promote excellence in public management to contribute to the quality of services provided to its customers and to increase competitiveness in the country, as well as its international projection. A technical barrier to trade that can lead to dissatisfaction and achieve the reputation of the institution is failing the test or calibration results and measurement data, thereby accreditation is regarded as the first essential step to facilitate the mutual acceptance of test results and calibration or measurement data. For recognition, laboratories need to demonstrate full compliance with both the sections of ISO/IEC 17025:2005, i.e. management and technical requirements. This research aims to discuss the critical aspects for implementation of ABNT NBR ISO / IEC 17025:2005 for calibration and testing of a Public Institution seeking accreditation of its laboratories with INMETRO, national accreditation body Laboratories. Besides getting preventive, corrective and improvement actions continues guidelines. Furthermore, the methodology used was to conduct a literature search and apply a questionnaire to identify the degree of agreement / disagreement of the foundations of the standard servers. Analysis of the results showed that the critical issues were: commitment, training, resources (infrastructure, human) and culture. (author)

  16. Inertial electrostatic confinement (IEC) fusion fundamentals and applications

    CERN Document Server

    Miley, George H

    2014-01-01

    This book provides readers with an introductory understanding of Inertial Electrostatic Confinement (IEC), a type of fusion meant to retain plasma using an electrostatic field. IEC provides a unique approach for plasma confinement, as it offers a number of spin-off applications, such as a small neutron source for Neutron Activity Analysis (NAA), that all work towards creating fusion power. The IEC has been identified in recent times as an ideal fusion power unit because of its ability to burn aneutronic fuels like p-B11 as a result of its non-Maxwellian plasma dominated by beam-like ions. This type of fusion also takes place in a simple mechanical structure small in size, which also contributes to its viability as a source of power. This book posits that the ability to study the physics of IEC in very small volume plasmas makes it possible to rapidly investigate a design to create a power-producing device on a much larger scale. Along with this hypothesis the book also includes a conceptual experiment propose...

  17. Strategies for Refining IEC 61400-2: Wind Turbine Generator Systems - Part 2: Safety of Small Wind Turbines: Preprint

    International Nuclear Information System (INIS)

    van Dam, J. J. D.; Forsyth, T. L.; Hansen, A. C.

    2001-01-01

    This paper provides a status of the changes currently being made by IEC Maintenance Team 02 (MT02) to the existing IEC 61400-2 ''Safety of small wind turbines.'' In relation to the work done by IEC MT02, work has been done by NREL and Windward Engineering under the DOE/NREL Small Wind Turbine (SWT) Project. Aeroelastic models were built and measurements taken on a Whisper H40 turbine and an AOC 15/50. Results from this study were used to verify the simple design equations. This verification will be used to evaluate how changes made in the design load estimation section of the standard work out for a broad range of turbine configurations. The work presented here builds on work performed by Van Hulle (1996)

  18. Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report for D19-0, D3-100, and D12-XXX Series Standards

    Science.gov (United States)

    2015-05-20

    Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12- XXX Series Standards NF...Candidate Type D19-0 ICP-AES Results ..................................................................... 4 Table V. Candidate Type D12- XXX ...Physical Property Results .................................................. 5 Table VI. Candidate Type D12- XXX Rotrode-AES Results

  19. Perancangan SMKI Berdasarkan SNI ISO/IEC27001:2013 dan SNI ISO/IEC27005:2013 (Studi Kasus DPTSI-ITS

    Directory of Open Access Journals (Sweden)

    Furqon Mauladani

    2018-03-01

    Full Text Available Institut Teknologi Sepuluh Nopember (ITS adalah salah satu universitas di Surabaya. ITS telah menggunakan TIK untuk keperluan operasional bisnisnya (contohnya isi kartu program studi, proses absensi, pembaharuan informasi, dan lainnya. Penggunaan TIK tidak dapat dipisahkan dari ancaman yang dapat mengganggu operasional TIK. Ancaman terdiri dari ancaman yang berasal dari luar (penyebaran malware, aktifitas social engineering, orang dalam (sengaja, tidak sengaja, kegagalan teknis (kesalahan penggunaan, kegagalan perangkat keras/lunak ataupun bencana alam (kebakaran, gempa, banjir. Metode yang digunakan pada penelitian ini adalah melakukan manajemen resiko keamanan informasi berdasarkan SNI ISO/IEC 27005 dan perancangan dokumen SMKI berdasarkan SNI ISO/IEC 27001. Hasil penelitian ini adalah 60 resiko yang tidak diterima dari total 228 resiko yang telah teridentifikasi. Dari 60 resiko tersebut, terdapat 58 risk modification, 1 risk avoidance, dan 1 risk sharing. Tata kelola keamanan informasi yang dirancang berdasarkan SNI ISO/IEC 27001 adalah ruang lingkup SMKI, kebijakan SMKI, proses penilaian resiko, proses penanganan resiko, statement of applicability, dan sasaran keamanan informasi.

  20. US-Japan IEC Workshop on Small Plasma and Accelerator Neutron Sources. Final report

    International Nuclear Information System (INIS)

    Miley, George H.

    2008-01-01

    The history of IEC development will be briefly described, and some speculation about future directions will be offered. The origin of IEC is due to the brilliance of Phil Farnsworth, inventor of electronic TV in the US. Early experiments were pioneered in the late 1960s by Robert Hirsch who later became head of the DOE fusion program. At that time studies of IEC physics quickly followed at the University of Illinois and at Penn State University. However, despite many successes in this early work, IEC research died as DOE funding stopped in the mid 1980s. In the early 90's, R. W. Bussard of EMC revived work with a new major project based on a magnetic assisted IEC. While doing supportive studies for that project, G. Miley proposed a grided 'STAR mode' IEC as a neutron source for NAA. This concept was later used commercially by Daimler-Benz in Germany to analysis impurities in incoming ores. This represented a first practical application of the IEC. During this period other research groups at LANL, U of Wisconsin and Kyoto University entered IEC research with innovative new concepts and approaches to IEC physics and applications. Much of this work is documented in the present and in past US-Japan Workshops. At present we stand on the threshold of a new area of IEC applications as neutron source, for isotope production, and as a plasma source. These applications provide a way to continue IEC understanding and technology development with the ultimate goal being a fusion power plant. Indeed, a distinguishing feature of the IEC vs. other fusion confinement approaches is the unique opportunity for 'spin off' applications along the way to a power producing plant.

  1. Characterization of radiation qualities used for the determination of characteristic in CT application according to IEC 61267:2005

    International Nuclear Information System (INIS)

    Dias, Daniel M.; Silva Junior, Iremar A. da; Potiens, Maria da Penha A.

    2009-01-01

    The purpose of this study was to establish the standard RQT radiation qualities which represent simulations of the unattenuated beam used in Computed Tomography (CT). Thus, to avoiding excessive efforts for establishing a radiation quality by means of the spectral distribution of the photon fluence, the characterization of these standard radiation qualities was expressed in terms of the X-ray tube voltage, first and second half-value layer (HVL). To establishing the standard radiation beam, according to the IEC 61267 and the TRS 457 was measured first of all the correct values of the X ray tube voltages in terms of Practical Peak Voltage. The standard radiation qualities RQT were produced using the same set up mounted for the RQR qualities which had been early established, and for simulating the patient in order to achieve the standard RQT series, suitable thicknesses of layers of copper were used to obtain the values of the first HVL according to IEC 61267. (author)

  2. The first IEC fusion industrial neutron generator and developments

    Science.gov (United States)

    Sved, John

    1999-06-01

    Inertial Electrostatic Confinement fusion grade plasma containment has been sporadically researched since the early 1960's. In the 1990's the work of G. H. Miley and his team at the University of Illinios, Fusion Studies Laboratory, Champaign-Urbana has stimulated a collaboration with industry. The development and test program for the first industrial IEC neutron generator has progressed to the point where an endurance test is under way to demonstrate at least 10,000 hours of operational life of the sealed chamber device without servicing. The market entry goals of steady 107 D-D n/s CW output with an air-cooled system have been achieved. DASA has invested in the development of the industrial product and the continuing basic research at the UI-FSL. The complete DASA FusionStar IEC-PS1 point source neutron generator set is described with emphasis on the interfaces to user NAA systems. The next product developments are pulsed neutron operations and higher fusion reaction rates of up to 1010 by means of affordable add-ons to the basic IEC-PS system. The production engineering experience gained will next be applied to a more challenging line source variant of the IEC. Beyond neutron and proton sources, several other IEC applications are being developed.

  3. Procedure for qualify class 1E equipment for nuclear power generating stations; Kvalifikacija elektroopreme za stjecanje klase 1E u nuklearnim elektranama

    Energy Technology Data Exchange (ETDEWEB)

    Smiljanic, D [' Rade Koncar' Institut, Zagreb (Yugoslavia)

    1983-07-01

    This paper describes the basic requirements for qualifying Class 1E equipment and systems that are to be used in nuclear power generating stations. The requirements presented include the principles, procedures and methods of qualification. The qualification requirements will confirm the adequacy of the equipment design under normal, abnormal, design basis event, post design basis event and containment test conditions for the performance of Class 1 E functions. The presented methods of qualification are in accordance with IEEE Standards and other standards (IEC, JUS, DIN, etc,), and have the primary role to provide guidance for demonstrating the qualification of Class 1E equipment produced by 'Rade Koncar'.(author)

  4. Qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This Standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. It may also be used to separately qualify actuator components. This Standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  5. Establishment of radiation qualities for radiodiagnostics in LCR/UERJ according to IEC 61267 and TRS 457

    International Nuclear Information System (INIS)

    Silva, D.B. da; Magalhaes, L.A.G.; Estrada, J.J.S.; Pires, E.J.; David, M.G.; Ferreira, N.M.P.D.

    2015-01-01

    The main goal of this work is to establish the radiation qualities of the Laboratório de Ciências Radiológicas (LCR) conventional X-ray equipment for calibrations in radiodiagnostics according to the recommendations of IEC 61267 and TRS 457. Tests were conducted to evaluate the homogeneity of the radiation field, high voltage applied to the X-ray tube, scattering, half-value layers (HVL) and homogeneity coefficients. The results obtained that characterize the radiation field, satisfy the conditions required by TRS 457. Invasive high voltage measures presented results compatible with the requirements of this standard. The HVL measures showed that for the first HVL the tolerance limits of IEC 61267, and the values for the homogeneity coefficients were within the limits established. The quality tests performed in this work were highly satisfactory in meeting the standard requirements. Thus, the main goal was achieved, and the methodology can be used by other similar X-ray systems. - Highlights: • Establishment the radiation qualities for X-ray calibrations in radiodiagnostics. • Comparison to kV between invasive and noninvasive method. • Determination of additional filtrations suggested by IEC 61267. • Determination of the radiation scattered by the experimental setup as TRS 457. • Determination of HVLs as TRS 457.

  6. Calibration Laboratory for Medical Physics towards ISO/ IEC 17025 accreditation: Experience and challenges

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Abdul Aziz Ramli; Muhammad Jamal Isa; Sharul Azlan Azizan

    2011-01-01

    Medical Physics Calibration Laboratory is laboratory where placed under Medical Physics Group, Radiation Healthy and Safety Division. This laboratory offers calibration services to their customers that covered doses calibration, tube voltan (kVp), exposure doses, sensitometer and densitometer. After 12 years of operation, it is the right time for this laboratory to upgrade their quality services based on ISO/ IEC 17025. Accreditation scope covered calibration for diagnostic doses only. Starting from 2009, serious effort was done to prepare the quality documents that covered quality manual, quality procedure and work orders. Meanwhile, several series of audit were done by Quality Management Center (QMC), now Innovation Management Center (IMC) with collaboration with Standard Department. This paper works revealed challenges and experience during the process toward ISO/ IEC 17025 accreditation. (author)

  7. IEC 61850 based refurbishment strategies for protection and automation systems

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    Electric utilities are currently facing the challenge of refurbishing aging transmission networks and power system infrastructure at a time of severe economic, environmental and competitive constraints. This paper addressed the issue of an appropriate approach to retrofit the hardware and software of substation secondary systems, and how IEC standards could be used to set up a long term strategy. The first part of the paper considered an asset management strategy for refurbishing substation secondary systems, while the second part of the paper addressed the strategies for refurbishing existing power plants. The final section of the paper analyzed refurbishment strategies designed to protect power distribution systems. The impact of IEC 61850 and how legacy devices can be integrated in substation automation systems were discussed. It was concluded that new SCADA systems are needed to handle new technology. Additional features like remote control, remote settings, remote disturbance records analysis and remote maintenance are also needed to properly operate the power system. The value of preventive maintenance using remote monitoring systems to determine the status of all the digital electronic devices installed in substation was also discussed. IEC 61850 offers several opportunities to improve grid operation and control. It supports interoperability between protective relays and control devices from different manufacturers in the substation, which is required in order to achieve substation level interlocking, protection and control functions and improve the efficiency of microprocessor based relays applications. This technology has now passed the initial stage of implementation and several projects are underway worldwide. 13 figs.

  8. Harmonization of welding qualification provisions in RCC-M and European standards

    International Nuclear Information System (INIS)

    Lemoine, M.; Lainez, B.; Anastassiades, P.

    2007-01-01

    Since a long time, numerous precautions for welding have been integrated in the nuclear codes, in particular in the RCC-M applicable to pressurized water reactors, in order to guarantee a high quality level of permanent assemblies. In parallel, European and ISO standardization works have led to a harmonisation of practices on qualification of welding processes, welders and operators. In the context of the regulatory evolutions presented during this conference, it was judged appropriate to bring closer the RCC-M practices and those of EN and ISO standards, while taking the precaution of specifying, if necessary, the complementary provisions allowing maintaining guarantees of quality consistent with the prior experience feedback. This paper presents the amendments brought to the RCC-M Code by the 2005 and 2007 addenda, in order to respond to this objective, and develops their motivations. (authors) [fr

  9. Migración de un SGSI basado en ISO/IEC 27001:2005 a la versión ISO/IEC 27001:2013

    OpenAIRE

    Espol; Rendón Freire, María José

    2015-01-01

    Este proyecto tiene como objetivo identificar los cambios en los requisitos de la norma ISO/IEC 27001:2013 respecto a la versión 2005, para lograr la actualización de un sistema de gestión de seguridad de la información basado en ISO/IEC 27001:2005 acorde a lo establecido en el nuevo estándar. Guayaquil Magíster en Seguridad Informática Aplicada

  10. Atomic processes in Inertial Electrostatic Confinement (IEC) devices

    International Nuclear Information System (INIS)

    Nebel, R.A.; Turner, L.; Tiouririne, T.N.; Barnes, D.C.; Nystrom, W.D.; Bussard, R.W.; Miley, G.H.; Javedani, J.; Yamamoto, Y.

    1993-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P. T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2*10 10 neutrons/sec. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. Atomic physics effects strongly influence the performance of all of these systems. Important atomic effects include elastic scattering, ionization, excitation, and charge exchange. This paper discusses how an IEC system is influenced by these effects and how to design around them. Theoretical modeling and experimental results are presented

  11. A fully automated system for ultrasonic power measurement and simulation accordingly to IEC 61161:2006

    NARCIS (Netherlands)

    Costa-Felix, R.P.B.; Alvarenga, A.V.; Hekkenberg, R.

    2011-01-01

    The ultrasonic power measurement, worldwide accepted, standard is the IEC 61161, presently in its 2nd edition (2006), but under review. To fulfil its requirements, considering that a radiation force balance is to be used as ultrasonic power detector, a large amount of raw data (mass measurement)

  12. Equipment qualification testing methodology research at Sandia Laboratories

    International Nuclear Information System (INIS)

    Jeppesen, D.

    1983-01-01

    The Equipment Qualification Research Testing (EQRT) program is an evolutionary outgrowth of the Qualification Testing Evaluation (QTE) program at Sandia. The primary emphasis of the program has been qualification methodology research. The EQRT program offers to the industry a research-oriented perspective on qualification-related component performance, as well as refinements to component testing standards which are based upon actual component testing research

  13. Concept for a high performance MHD airbreathing-IEC fusion rocket

    International Nuclear Information System (INIS)

    Froning, H.D. Jr.; Miley, G.H.; Nadler, J.; Shaban, Y.; Momota, H.; Burton, E.

    2001-01-01

    Previous studies have shown that Single-State-to-Orbit (SSTO) vehicle propellant can be reduced by Magnets-Hydro-Dynamic (MHD) processes that minimize airbreathing propulsion losses and propellant consumption during atmospheric flight, and additional reduction in SSTO propellant is enabled by Inertial Electrostatic Confinement (IEC) fusion, whose more energetic reactions reduce rocket propellant needs. MHD airbreathing propulsion during an SSTO vehicle's initial atmospheric flight phase and IEC fusion propulsion during its final exo-atmospheric flight phase is therefore being explored. Accomplished work is not yet sufficient for claiming such a vehicle's feasibility. But takeoff and propellant mass for an MHD airbreathing and IEC fusion vehicle could be as much as 25 and 40 percent less than one with ordinary airbreathing and IEC fusion; and as much as 50 and 70 percent less than SSTO takeoff and propellant mass with MHD airbreathing and chemical rocket propulsion

  14. Concept for a high performance MHD airbreathing-IEC fusion rocket

    Science.gov (United States)

    Froning, H. D.; Miley, G. H.; Nadler, J.; Shaban, Y.; Momota, H.; Burton, E.

    2001-02-01

    Previous studies have shown that Single-State-to-Orbit (SSTO) vehicle propellant can be reduced by Magnets-Hydro-Dynamic (MHD) processes that minimize airbreathing propulsion losses and propellant consumption during atmospheric flight, and additional reduction in SSTO propellant is enabled by Inertial Electrostatic Confinement (IEC) fusion, whose more energetic reactions reduce rocket propellant needs. MHD airbreathing propulsion during an SSTO vehicle's initial atmospheric flight phase and IEC fusion propulsion during its final exo-atmospheric flight phase is therefore being explored. Accomplished work is not yet sufficient for claiming such a vehicle's feasibility. But takeoff and propellant mass for an MHD airbreathing and IEC fusion vehicle could be as much as 25 and 40 percent less than one with ordinary airbreathing and IEC fusion; and as much as 50 and 70 percent less than SSTO takeoff and propellant mass with MHD airbreathing and chemical rocket propulsion. .

  15. Instrumentation qualification. Seismic qualification of C-E instrumentation equipment. Part One

    International Nuclear Information System (INIS)

    1977-05-01

    A summary of the C-E seismic qualification program utilized to demonstrate the seismic design adequacy of the instrumentation and control equipment used in C-E supplied Nuclear Steam Supply Systems (NSSS) is presented. The report is divided into two parts. Part One includes the equipment seismic requirements and a description of the qualification methods. Part Two lists the specific equipment by nuclear station in which it is used and the equipment test results are summarized in a standard data sheet format to facilitate review. The seismic requirements are based on individual contract commitments with C-E customers and the NRC Standard Review Plan, Section 3.10 ''Seismic Qualification of Category I Instrumentation and Electrical Equipment.'' Equipment is qualified for use in a seismic environment where damage potential to the equipment is less than or equal to that simulated seismic environment to which it has been qualified. The anticipated Safe Shutdown Earthquake (SSE) environment at the inservice location of equipment should be confirmed by each applicant as not exceeding that to which it is qualified

  16. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  17. Gloss uniformity measurement update for ISO/IEC 19751

    Science.gov (United States)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  18. IEC Information Bulletin, No. 39, First Quarter 2012

    International Nuclear Information System (INIS)

    2012-01-01

    On 28 March, the Incident and Emergency Centre (IEC) conducted its first Full Response Exercise of 2012. Over 30 staff members from the Department of Nuclear Safety and Security and the Division of Public Information participated. The IEC was activated into full response mode at approximately 9 a.m. This full response lasted most of the day and led up to a 'lessons learned' discussion at the end of the day. Florian Baciu, the IEC Response System Coordinator, noted: ''Although many of the participants were involved in the IAEA response to the accident at TEPCO's Fukushima Daiichi nuclear power plant, this exercise gave them the opportunity to practice procedures which they had not used since then. In addition, we had several staff members relatively new to the IAEA's Incident and Emergency System among the participants.'' Hilaire Mansoux, one of the Emergency Response Managers for the exercise, stated: ''The scenario was quite complex, requiring a good flow of information.'' The IEC staff had developed a scenario in which a meltdown and resulting release of radioactive materials to the environment from a nuclear power plant in a Member State was caused by a criminal act. All outside organizations were represented by the IEC staff in a simulation cell, which periodically contributed information using telephone calls, faxes, emails and messages through the IAEA's Unified System for Information Exchange in Incidents and Emergencies (USIE). The tasks of the IAEA in the area of emergency response were expanded through the mandate given by Member States following the events at Fukushima Daiichi last year. In the area of communication and information dissemination, the IAEA was also given, among other tasks, the mandate to assess emergency situations by providing 'analysis of available information and prognosis of possible scenarios'. Together with other matters, the assessment aspect was addressed in this full response exercise.

  19. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC

    International Nuclear Information System (INIS)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-01-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  20. Establishment of nuclear equipment qualification system

    International Nuclear Information System (INIS)

    Joo, Po Kook; Lim, Nam Jin; Lee, Young Gun

    2003-04-01

    This study is carried out by KEARI(Korea Atomic Energy Research Institute) as the lead organization in cooperation with KIMM(Korea Institute of Machinery and Materials), KTL(Korea Testing Laboratory) and KRISS(Korea Research Institute of Standards and Science) to construct a basis of efficient management of nuclear equipment qualification business by expanding test equipment of each of participating organization, and developing qualification technologies. As for KIMM, control system of large scale shaker was replaced with advanced system, and LOCA(Loss of Coolant Accident) test facility was installed. KTL is now capable of conducting seismic tests of nuclear I and C as a result of installation of seismic test equipment during the first two project years. KRISS participated in the Project with a view to have large scale EMI test equipment and related technologies. In parallel with expansion of test equipment, a industrial-educational-research cooperation committee, as an intermediate step toward integrated equipment qualification system to maximize the usage of test equipment, was established and cooperation methods were investigated. As a result, Korea Nuclear Equipment Qualification Association, an corporate juridical person, was established. Research on development of thermal and radiation aging test technology of nuclear materials was carried out by Hanyang University and SECO(Saehan Engineering and Qualification Co., Ltd.). Integrated Equipment Qualification Database was developed which contains material test data, equipment qualification data and other EQ related informations. Standard qualification procedures were developed in order for test laboratories and manufacturers to establish design requirements and to efficiently perform tests

  1. A quality assurance system for personal monitoring in Ireland: experience to date and transition from EN 45001 to ISO/IEC 17025

    International Nuclear Information System (INIS)

    Currivan, L.; Spain, D.; Rafferty, B.

    2002-01-01

    Up to 2000 the RPII was the competent authority for approval of dosimetry services operating within Ireland. However the transposition into Irish Law of Council Directive 96/29 Euratom in May 2000 means that dosimetry services operating in Ireland must now attain accreditation to the standard of EN-45001 or its equivalent. To comply with this new legislation the RPII sought accreditation for the Dosimetry Service from the Irish National Accreditation Board (NAB). In accordance with the EN-45000 series of European Standards and the relevant ISO guides NAB tests accuracy of results and accredits organisations as appropriate. In September 2000 accreditation was granted to the Dosimetry Service for individual monitoring of personnel who are occupationally exposed to ionising radiation. The scope of the accreditation covers the evaluation of personal doses, for photon and beta, using TLD. Frequent internal quality audits, together with periodic inter-laboratory test programmes, ensure that these quality standards are maintained. This accreditation fulfils the approval under legislation for dosimetry services. The new standard, ISO/IEC 17025, was introduced by ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) in 1999. This standard was introduced in Ireland by NAB and will be implemented for future assessments. The aim of this paper is to describe the quality system currently operated by the RPII's Dosimetry Service, our practical experience to date, and to outline the transition from EN-45001 to ISO/IEC 17025

  2. Techniques and tools for software qualification in KNICS

    International Nuclear Information System (INIS)

    Cha, Kyung H.; Lee, Yeong J.; Cheon, Se W.; Kim, Jang Y.; Lee, Jang S.; Kwon, Kee C.

    2004-01-01

    This paper describes techniques and tools for qualifying safety software in Korea Nuclear Instrumentation and Control System (KNICS). Safety software are developed and applied for a Reactor Protection System (RPS), an Engineered Safety Features and Component Control System (ESF-CCS), and a safety Programmable Logic Controller (PLC) in the KNICS. Requirements and design specifications of safety software are written by both natural language and formal specification languages. Statechart is used for formal specification of software of the ESF-CCS and the safety PLC while NuSCR is used for formal specification of them of the RPS. pSET (POSCON Software Engineering Tool) as a software development tool has been developed and utilized for the IEC61131-3 based PLC programming. The qualification of the safety software consists of software verification and validation (V and V) through software life cycle, software safety analysis, and software configuration management, software quality assurance, and COTS (Commercial-Off-The-Shelf) dedication. The criteria and requirements for qualifying the safety software have been established with them in Software Review Plan (SRP)/Branch Technical Positions (BTP)-14, IEEE Std. 7-4.3.2-1998, NUREG/CR-6463, IEEE Std. 1012-1998, and so on. Figure 1 summarizes qualification techniques and tools for the safety software

  3. Compatibility of IEC 61400-27-1 Ed 1 and WECC 2nd Generation Wind Turbine Models

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sørensen, Poul Ejnar; Morales, Ana

    2016-01-01

    , respectively. Although the two working groups have been collaborating closely, there are small differences between the approaches of the two modelling standards, especially in terms of parameter sets and complexities for different functions. In this paper, compatibility of the IEC and WECC wind turbine models...

  4. Present problems of standardization in nuclear instrumentation in Romania

    International Nuclear Information System (INIS)

    Purghel, Lidia

    2001-01-01

    The continuos development of nuclear techniques, based on international cooperation, led to the need for producing national and international standards referring to terminology, classification, technical characteristic, testing and calibration methods for nuclear instrumentation. The international standardization activity is organised in the frame of the well-known organization like IEC, ISO, ICRU, ICRP, IOLM, CENELEC, EFOMP, WHO. High advances were obtained in the standardization of the ionising radiation dosimetry in the frame of the International Commission for Radiation Units (ICRU) which started its works 1925. Romania is member of the International Electrotechnical Commission (IEC) from 1920 when its president was the formal member of Romanian Academy, professor Remus Radulet. Romania is effectively involved in standardization activities in the field nuclear instrumentation both as user and manufacturer of nuclear instrumentation. At national level the Technical Committee 45, as a branch of the Romanian Electrotechnical Committee is hosted by Horia Hulubei National Institute for Physics and Nuclear Engineering. The technical committee has the tasks of analysing the market, the regulations and the industry requirements and proposing new standards or revision for existing one. A table is given showing the number of IEC standards considered by TC 45, adopted RS - IEC standards (prepared/published) and planned for 2000/2001. Romania hosted IEC international plenary meetings in 1962 and 1974 and an IEC workshop 1997 with participation of specialists from USA, Sweden, Germany, France, Japan and Romania. As industry is striving to use more and more standard products, that means best quality and safety for less money, more than ever one have to convince the industry about the usefulness and specificity of the nuclear standards

  5. IEC Based D-3He Fusion for Space Propulsion

    International Nuclear Information System (INIS)

    Miley, George H.; Burton, R.; Richardson, N.; Shaban, Y.; Momota, Hiromu

    2002-01-01

    A preliminary system design is presented for a high performance 100-MWe manned space vehicle in the 500 metric ton class, based on Inertial Electrostatic Fusion (IEC), allowing trip times to the outer planets of several months. An IEC is chosen because it's simplified structure results in a very high power-to-weight ratio. D- 3 He fuel is used to give 14.7-MeV protons as a primary fusion reaction product. Direct conversion of proton energy to electricity is employed, providing a high efficiency. An IEC reactor with a proton energy gain (power in 14.7-MeV protons/input electric power) of 4 or better is assumed. Extrapolation of present laboratory scale IEC experiments to such conditions is possible theoretically, but faces several open issues that require further study such as stability under high-density conditions. The final thruster is based on an NSTAR-extrapolated krypton ion design with a specific impulse of 16,000 seconds and a total thrust of 1020 N. Round trip thrust time for mission set to Jupiter ΔV of 100 km/s is then ∼950 days. (authors)

  6. Can we use IEC 61850 for safety related functions?

    Directory of Open Access Journals (Sweden)

    Luca Rocca

    2016-08-01

    Full Text Available Safety is an essential issue for processes that present high risk for human beings and environment. An acceptable level of risk is obtained both with actions on the process itself (risk reduction and with the use of special safety systems that switch the process into safe mode when a fault or an abnormal operation mode happens. These safety systems are today based on digital devices that communicate through digital networks. The IEC 61508 series specifies the safety requirements of all the devices that are involved in a safety function, including the communication network. Also electrical generation and distribution systems are processes that may have a significant level of risk, so the criteria stated by the IEC 61508 applies. Starting from this consideration, the paper analyzes the safety requirement for the communication network and compare them with the services of the communication protocol IEC 61850 that represents the most used protocol for automation of electrical plants. The goal of this job is to demonstrate that, from the technical point of view, IEC 61850 can be used for implementing safety-related functions, even if a formal safety certification is still missing.

  7. Guidelines for seismic qualification by experience in ALWRs

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.

    1994-01-01

    The methodologies and acceptance criteria for seismic qualification of equipment are provided in IEEE Std. 344 endorsed by the Nuclear Regulatory Commission (NRC) in the Standard Review Plan. The IEEE Standard allows seismic qualification by use of the similarity analysis method. Data available from past earthquake events or vibration tests can be used in this regard. The nuclear industry has collected a vast amount of earthquake experience and test data in the last decade, and is planning to use it for seismic qualification of equipment in advanced light water reactor (ALWR) plants. This paper discusses the existing data bases including their limitations and describes the ways these data bases can be used for equipment qualification in ALWR plants

  8. Guidelines for seismic qualification by experience in ALWRs

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.

    1993-01-01

    The methodologies and acceptance criteria for seismic qualification of equipment are provided in IEEE Std. 344 endorsed by the Nuclear Regulatory Commission (NRC) in the Standard Review Plan. The IEEE Standard allows seismic qualification by use of the similarity analysis method. Data available from past earthquake events or vibration tests can be used in this regard. The nuclear industry has collected a vast amount of earthquake experience and test data in the last decade, and is planning to use it for seismic qualification of equipment in advanced light water reactor (ALWR) plants. This paper discusses the existing data bases including their limitations and describes the ways these data bases can be used for equipment qualification in ALWR plants

  9. Use of the TEM Cell for Compliance Testing of Emissions and Immunity, an IEC Perspective

    DEFF Research Database (Denmark)

    Bentz, Sigurd

    1996-01-01

    The current work of the IEC on preparing a standard for the use of TEM cells for compliance testing of emissions and immunity is reviewed. The requirements of TEM cells are related to the established procedures: “open area test site” and “shielded enclosure with area of uniform field”, respective...

  10. The Load Level of Modern Wind Turbines according to IEC 61400-1

    International Nuclear Information System (INIS)

    Freudenreich, K; Argyriadis, K

    2007-01-01

    The paper describes some effects on the load level of state-of-the art multi megawatt wind turbines introduced by the new edition of the standard IEC 61400-1:2005 W ind Turbines - Part 1: Design requirements . Compared to the previous edition, especially the extreme load determination has been modified by applying stochastic and statistical analyses. Within this paper the effect on the overall load level of wind turbines is demonstrated and occurring problems are discussed. Load simulations have been carried out for four state-of-the-art multi-megawatt wind turbines of different design concepts and from different manufacturers. The blade root bending moments and tip deflection have been determined by applying different extrapolation methods. Advantages and disadvantages of these methods and tail fittings for different load components and wind turbine technologies are discussed and interpreted. Further on, the application of the extreme turbulence model is demonstrated. The dependence of the load level on the turbulence intensity and control system, as well as the interaction with extrapolated loads is discussed and limitations outlined. The obtained load level is compared to the overall load level of the turbines according to the previous edition of the standard, IEC 61400-1:1999

  11. Development of an international standard on instruments setpoints based on ISA S67.04 - 1994

    International Nuclear Information System (INIS)

    Quinn, E.L.

    1996-01-01

    This is a summary of the application for and development of an international standard on instrument setpoints, based on the Instrument Society of America (ISA) Standard S67.04 - 1994. The forum this new standard was proposed in is the International Electrotechnique Commission (IEC), based in Geneva, Switzerland, which is the international commission which oversees electrical and instrumentation standards for all applications around the world. The Instrument Society of America (ISA) is a United States based Society for the advancement of instrumentation and controls related science and technology and has 30,000 members. A division within the ISA is the Standard and Practices board which has over 5000 members actively involved in standards development and approval. In 1994, the ISA SP67, Nuclear Power Plant Standards Committee authorized that the IEC be approached to develop and issue an IEC standard on Instrument Setpoints. This application was formally submitted in January, 1995 to the IEC and approved for ballot to member countries in June, 1995. Approval for standard development by IEC was received in October, 1995 and the first draft vas issued in February, 1996, and is currently under review by the IEC working group. It is very important to focus on the approach that the U.S. and other countries are taking toward development of IEC standards that can apply to all nuclear instrumentation applications around the world. By referencing IEC standards in design specification, vendors can be solicited from many different countries, thereby ensuring that the highest quality products can be used. This also offsets the need to specify individual standards in the specification, based on the country that each vendor solicited, represents. In summary, this standard development process, with support from the American National Standards Institute (ANSI) will assist U.S. suppliers in competing in the global market for products and services into the next century. (author)

  12. Return of IEEE Std 627 and its Value to Equipment Qualification Programs

    International Nuclear Information System (INIS)

    Horvath, D.A.

    2012-01-01

    IEEE Std 627 ''Design Qualification of Safety Systems Equipment Used in Nuclear Power Generating Stations'' was issued to more generically establish qualification requirements in the form of a high level umbrella document. Efforts on this standard began in late 1975 at the request of the IEEE Nuclear Standards Management Board. In 1977 a joint ASME/IEEE agreement established responsibility for qualification and quality assurance standards preparation. ASME accepted responsibility for Quality Assurance and IEEE for qualification. In accordance with that agreement, IEEE completed the generic qualification standard in 1980. This document provided high level approaches, criteria, guidance, and principles for qualification of both electrical and mechanical equipment that at that time appeared in no other industry standard. IEEE Std 627-1980 was later reaffirmed in 1996. In 1986, ASME's Board on Nuclear Codes and Standards directed its Committee on Qualification of Mechanical Equipment (QME) to develop a standard for qualifying mechanical equipment. This task was completed in several parts during the time frame from 1992 to 1994. Partly in response to this activity, IEEE Std 627 was withdrawn in 2002. Later although withdrawn, it was found that IEEE Std 627 was continuing to be used and referenced by many entities both in the US and other countries including in ASME's QME-1-2002 ''Qualification of Active Mechanical Equipment Used in Nuclear Power Plants'', US NRC's NUREG-0800 Standard Review Plan Section 3.11, at least one reactor vendor's Design Certification Document (DCD), several international licensing documents, and elsewhere. As a result, in 2007, the IEEE Standards Board authorized Working Group 2.10 of Subcommittee 2 (Qualification) of the Power and Energy Society's Nuclear Power Engineering Committee to resurrect and update IEEE Std 627-1980 (Reaff 1996). The result was the culmination IEEE Std 627 in 2010. This paper will report on the eight improvements made

  13. Program plan for environmental qualification of mechanical and dynamic (including seismic) qualification of mechanical and electrical equipment program (EDQP)

    International Nuclear Information System (INIS)

    Weidenhamer, G.H.

    1986-06-01

    The equipment qualification program described in this plan is intended to provide the technical basis for resolving uncertainties in existing equipment qualification standards. In addition, research results are contributing to the resolution of safety issues GI-23, GI-87, USI-A44, titled, ''Reactor Coolant Pump Seal Failure,'' ''Failure of HPCI Steam Line Without Isolation,'' and ''Station Blackout,'' respectively. Also, research effort is being directed at providing information on the behavior of containment isolation valves under severe accident environments. Although the results of the latter research will not contribute to resolving uncertainties in qualification standards, it has proven cost effective to obtain this information under this program

  14. IEC-based neutron generator for security inspection system

    International Nuclear Information System (INIS)

    Miley, G.H.; Wu, L.; Kim, H.J.

    2005-01-01

    Use of a combined X-ray and neutron source for security inspections based on Inertial Electrostatic Confinement (IEC) fusion is discussed. Current inspection systems typically use X-ray techniques, but thermal neutron analysis (TNA) and fast neutron analysis (FNA), allow expanded detection of certain types of explosives. The integrated unit proposed here uses three separate IEC sources producing 14 and 2.45 MeV neutrons plus soft X-rays. This combination allows multiple detection methods with the composite signal analysis being done by a fuzzy logic system, significantly reducing false signals. (author)

  15. A collimator-converter system for IEC propulsion

    International Nuclear Information System (INIS)

    Momota, Hiromu; Miley, George H.

    2002-01-01

    The collimator-converter system extracts fusion power from D- 3 He fueled IEC devices and provides electricity needed to operate ionic thrusters and other-power components. The whole system is linear and consists of a series of collimator units at the center, magnetic expander units at both sides of the fusion units, followed by direct energy converters at both ends. This system is enclosed in a vacuum chamber with a magnetic channel provided by magnetic solenoids out of respective chambers. The fusion unit consists of an IEC fusion core, a pair of coils anti-parallel to the solenoid coils, and a stabilization coil that stabilizes the position of coil pair coils. The IEC fusion core is installed at the center of the pair coils. After the magnetic expander, velocities of fusion particles from D- 3 He fueled IEC units are directed to the magnetic channel, which guides energetic fusion particles as well as leaking unburned fuel components to a high-efficiency traveling wave direct energy converter (TWDEC). Leaking unburned fuel components are separated with a magnetic separator at the entrance of a direct energy converter and pumped out for further refueling. A TWDEC is made of an array of metallic meshed grids, each of which is connected to every terminal with an external transmission circuit. The transmission line couples to the direct energy converter. Substations for electricity, a cryogenic plant, and various power control systems are outside of the vacuum chamber. The length of the cylindrical system is essentially determined by the proton energy of 14.8 MeV and the radius should be large so as to reduce power flow density. The present system provides 250 MW f fusion power and converting it to 150 MW c electricity. Its size is 150 m(length)x6.6 m(diameter) in size and 185 tons in weight

  16. Modular structure of wind turbine models in IEC 61400-27-1

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Andresen, Bjørn; Fortmann, Jens

    2013-01-01

    This paper presents the modular structure of wind turbine models to be published in a new standard IEC 61400-27 for “Electrical simulation models for wind power generation”. The purpose of this standardization work is to define generic simulation models for wind turbines (Part 1) and wind power...... plants (Part 2), which are intended for short-term power system stability analyses. Part 1 has passed the first committee draft stage, whereas Part 2 is in an early stage of development. Initially, the paper describes the interfaces between wind turbine, wind power plant and grid models, and then gives...... a more detailed description of the modular structure of the types of wind turbines that are included in Part 1....

  17. Adaptive Micro-Grid Operation Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Wei Deng

    2015-05-01

    Full Text Available Automatically identifying the new equipment after its integration and adjusting operation strategy to realize “plug and play” functionality are becoming essential for micro-grid operations. In order to improve and perfect the micro-grid “plug and play” function with the increased amount of equipment with different information protocols and more diverse system applications, this paper presents a solution for adaptive micro-grid operation based on IEC 61850, and proposes the design and specific implementation methods of micro-grid “plug and play” function and system operation mode conversion in detail, by using the established IEC 61850 information model of a micro-grid. Actual operation tests based on the developed IED and micro-grid test platform are performed to verify the feasibility and validity of the proposed solution. The tests results show that the solution can automatically identify the IEC 61850 information model of equipment after its integration, intelligently adjust the operation strategies to adapt to new system states and achieves a reliable system operation mode conversion.

  18. Critical issues for implementation of the standard NBR ISO/IEC 17025:2005 in Testing and Calibration Laboratory: case study at a public institution; Aspectos criticos para implantacao da norma NBR ISO/IEC 17025:2005 em laboratorio de ensaio e calibracao: estudo de caso em uma instituicao publica

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Denise Confar Carvalho de

    2013-07-01

    The public institution aims to promote excellence in public management to contribute to the quality of services provided to its customers and to increase competitiveness in the country, as well as its international projection. A technical barrier to trade that can lead to dissatisfaction and achieve the reputation of the institution is failing the test or calibration results and measurement data, thereby accreditation is regarded as the first essential step to facilitate the mutual acceptance of test results and calibration or measurement data. For recognition, laboratories need to demonstrate full compliance with both the sections of ISO/IEC 17025:2005, i.e. management and technical requirements. This research aims to discuss the critical aspects for implementation of ABNT NBR ISO / IEC 17025:2005 for calibration and testing of a Public Institution seeking accreditation of its laboratories with INMETRO, national accreditation body Laboratories. Besides getting preventive, corrective and improvement actions continues guidelines. Furthermore, the methodology used was to conduct a literature search and apply a questionnaire to identify the degree of agreement / disagreement of the foundations of the standard servers. Analysis of the results showed that the critical issues were: commitment, training, resources (infrastructure, human) and culture. (author)

  19. Qualification of box HEPA filters for nuclear applications

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Wilson, K.; Rainer, F.

    1995-03-01

    We have successfully completed qualification tests on high efficiency particulate air (HEPA) filters that are encapsulated within a box and manufactured by American Air Filters. The qualification tests are required by the American Society of Mechanical Engineers Standard ASME N509 and the U.S. Military Standard MIL-F-51068 for HEPA filters to be used in nuclear applications. The qualification tests specify minimum filter efficiencies following exposure to heated air, overpressure, and rough handling. Prior to this study, no box HEPA filters from any manufacturer had been qualified despite their wide-spread use in Department of Energy (DOE) facilities. Box HEPA filters are not addressed in any of the existing HEPA standards and only briefly discussed in the Nuclear Air Cleaning Handbook

  20. Minimum qualifications for nuclear criticality safety professionals

    International Nuclear Information System (INIS)

    Ketzlach, N.

    1990-01-01

    A Nuclear Criticality Technology and Safety Training Committee has been established within the U.S. Department of Energy (DOE) Nuclear Criticality Safety and Technology Project to review and, if necessary, develop standards for the training of personnel involved in nuclear criticality safety (NCS). The committee is exploring the need for developing a standard or other mechanism for establishing minimum qualifications for NCS professionals. The development of standards and regulatory guides for nuclear power plant personnel may serve as a guide in developing the minimum qualifications for NCS professionals

  1. Wind power communication design and implementation of test environment for IEC61850/UCA2

    Energy Technology Data Exchange (ETDEWEB)

    Johnsson, A.; Svensson, J.

    2002-04-01

    Elforsk has sponsored a joint Swedish-Danish project aiming at finding and recommend a common solution for communication with wind power plants. The first stage of the work resulted in a requirement specification Functional Requirements on Communication System for Wind Turbine Applications. During the project a number of possible communication solutions were identified. The two most promising solutions have been tested in order to verify to what extent they fulfil the requirements in the specification. A version of the IEC 61850 standard based on the communication protocol MMS, has been tested at a wind power plant at Gotland, Sweden, and an OPC-interface has been tested in Denmark. This report includes a description of the design choices made for the test implementation of MMS, as well as a detailed description of the implementation of the IEC 61850/UCA2 software including information models and information exchange services. (BA)

  2. A British standard for inspection qualification - a step on the road to European harmonization

    International Nuclear Information System (INIS)

    Waites, C.; Leyland, K.S.; Whittle, M.J.

    1993-01-01

    The safety case for the Sizewell 'B' reactor requires the ultrasonic inspection of certain components to be validated independently of those directly responsible for reactor construction and operation. This paper describes how this has been done. To illustrate the way in which validation needs to be tailored to particular requirements, an example is given involving the application of a time-of-flight detection (TOFD) technique to in-service inspection of a weld from an offshore installation. The experience gained from the application above and from other work has enabled an approach to validation to be set out in a British Standard Draft for Development. The intent is to provide a methodology within which individual validations can be developed in a consistent and coherent way. A European Methodology for Inspection Qualification also builds on this and other experience and aims to promote a common approach within Europe. The intent is to define a qualification approach to NDT which provides the necessary confidence in the test in the most cost-effective way possible. (author)

  3. The suitability of the IEC 61400-2 wind model for small wind turbines operating in the built environment★

    Directory of Open Access Journals (Sweden)

    Evans Samuel P.

    2017-01-01

    Full Text Available This paper investigates the applicability of the assumed wind fields in International Electrotechnical Commission (IEC standard 61400 Part 2, the design standard for small wind turbines, for a turbine operating in the built environment, and the effects these wind fields have on the predicted performance of a 5 kW Aerogenesis turbine using detailed aeroelastic models developed in Fatigue Aerodynamics Structures and Turbulence (FAST. Detailed wind measurements were acquired at two built environment sites: from the rooftop of a Bunnings Ltd. warehouse at Port Kennedy (PK (Perth, Australia and from the small wind turbine site at the University of Newcastle at Callaghan (Newcastle, Australia. For both sites, IEC 61400-2 underestimates the turbulence intensity for the majority of the measured wind speeds. A detailed aeroelastic model was built in FAST using the assumed wind field from IEC 61400-2 and the measured wind fields from PK and Callaghan as an input to predict key turbine performance parameters. The results of this analysis show a modest increase in the predicted mean power for the higher turbulence regimes of PK and Callaghan as well as higher variation in output power. Predicted mean rotor thrust and blade flapwise loading showed a minor increase due to higher turbulence, with mean predicted torque almost identical but with increased variations due to higher turbulence. Damage equivalent loading for the blade flapwise moment was predicted to be 58% and 11% higher for a turbine operating at Callaghan and PK respectively, when compared with IEC 61400-2 wind field. Time series plots for blade flapwise moments and power spectral density plots in the frequency domain show consistently higher blade flapwise bending moments for the Callaghan site with both the sites showing a once-per-revolution response.

  4. COMBINING ITIL, COBIT AND ISO/IEC 27002 FOR STRUCTURING COMPREHENSIVE INFORMATION TECHNOLOGY FOR MANAGEMENT IN ORGANIZATIONS

    Directory of Open Access Journals (Sweden)

    Maico Gehrmann

    2012-09-01

    Full Text Available Several methodologies, tools and standards have been designed to help IT management within organizations. Companies seek, with the use of these mechanisms, the placement of IT management and organizational strategies, mainly to ensure that IT helps with the objectives of the business and the results of the organization. Despite the vast amount of options for tools, methodologies and standards available, when they are used independently, these are not sufficiently wide-ranging to meet all the needs of IT management. This document analyzes ITIL, COBIT and ISO/IEC 27002 methodologies through literature review, highlighting their similarities and differences through the comparison between them. From this analysis, an overall structure is proposed which uses a combination of ITIL, COBIT and ISO/IEC 27002 that can be used by any organization as a more comprehensive solution for the handling and servicing of IT management. As any process, there are positive and negative points. Some negative points of a methodology may be strengthened by the positive ones of other methodologies. This creates more efficient processes.

  5. Combining ITIL, COBIT and ISO/IEC 27002 for structuring comprehensive information technology for management in organizations

    Directory of Open Access Journals (Sweden)

    Maico Gehrmann

    2012-09-01

    Full Text Available Several methodologies, tools and standards have been designed to help IT management within organizations. Companies seek, with the use of these mechanisms, the placement of IT management and organizational strategies, mainly to ensure that IT helps with the objectives of the business and the results of the organization. Despite the vast amount of options for tools, methodologies and standards available, when they are used independently, these are not sufficiently wide-ranging to meet all the needs of IT management. This document analyzes ITIL, COBIT and ISO/IEC 27002 methodologies through literature review, highlighting their similarities and differences through the comparison between them. From this analysis, an overall structure is proposed which uses a combination of ITIL, COBIT and ISO/IEC 27002 that can be used by any organization as a more comprehensive solution for the handling and servicing of IT management. As any process, there are positive and negative points. Some negative points of a methodology may be strengthened by the positive ones of other methodologies. This creates more efficient processes.

  6. Impact Of IEC Intervention On Knowledge Regarding AIDS Amongst Senior Secondary School Children Of East Delhi

    Directory of Open Access Journals (Sweden)

    Bhasin S. K

    1999-01-01

    Full Text Available Research questions: 1. What is the level of awareness regarding HIV/AIDS amongst school children in East Delhi? 2. What is the impact of IEC intervention on the level of awareness regarding HIV/AIDS in these children? Objective: To find out the impact of IEC intervention on awareness regarding HIV/AIDS amongst senior secondary boys and girls in schools of East Delhi. Study design: Pre and post IEC interventional study. Settings: In four randomly selected senior secondary schools in East Delhi. Participants: 294 boys and 333 girls of class XI and XII in pre IEC group and 239 boys and 203 girls in post IEC group. Intervention: An IEC package of exhibition of posters, videotapes and intra group open discussion. Outcome variables: Proportion (prevalence of school children having correct knowledge of various aspects of HIV/AIDS after IEC intervention. Statistical analysis: Chi-square test. Results: IEC intervention significantly generated an enhancing effect on most aspects of their awareness towards HIV/AIDS among both boys and girls. Conclusions: There is an urgent need to impart health education for dispelling misconceptions regarding this disease.

  7. Nuclear power plants. Electrical equipment of the safety system. Qualification

    International Nuclear Information System (INIS)

    2001-01-01

    This International Standard applies to electrical parts of safety systems employed at nuclear power plants, including components and equipment of any interface whose failure could affect unfavourably properties of the safety system. The standard also applies to non-electrical safety-related interfaces. Furthermore, the standard describes the generic process of qualification certification procedures and methods of qualification testing and related documentation. (P.A.)

  8. Materials qualification for nuclear power plants

    International Nuclear Information System (INIS)

    Braconi, F.

    1987-01-01

    The supply of materials to be used in the fabrication of components submitted to pressure destined to Atucha II nuclear power plant must fulfill the quality assurance requirements in accordance with the international standards. With the aim of promoting the national participation in CNA II, ENACE had the need to adapt these requirements to the national industry conditions and to the availability of official entities' qualification and inspection. As a uniform and normalized assessment for the qualification of materials did not exist in the country, ENACE had to develop a materials suppliers qualification system. This paper presents a suppliers qualification procedure, its application limits and the alternative procedures for the acceptance of individual stock and for the stock materials purchase. (Author)

  9. International standard for the charging of electric vehicles; Internationaler Standard fuer das Laden von Elektrofahrzeugen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Mathoy, A.

    2001-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the situation regarding the standardisation of battery charging systems for electric vehicles. The advantages of an international standard both for users and manufacturers of electrically-powered vehicles are discussed. The work done in the IEC and CENELEC technical committees is reviewed. Developments achieved since 1999 are reviewed and further developments and work to be done are examined. The most important points in the IEC standard 61851 are looked at and various connector interfaces are described. Direct and inductive charging systems according to IEC 61980 are examined and the special situation in Italy, where power available in homes for the charging of electrical vehicles is more limited, is reviewed.

  10. Safety review for seismic qualification on nuclear power plant equipment

    International Nuclear Information System (INIS)

    Fang Qingxian

    1995-01-01

    The standards and requirements for seismic qualification of nuclear power plant's component have been fully addressed, including the scope of seismic qualification, the approach and the method of common seismic qualification, the procedure of the seismic tests, and the criteria for the seismic qualification review. The problems discovered in the safety review and the solution for these problems and some other issues are also discussed

  11. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  12. SINUPERM N: a new digital neutron flux density monitoring system

    International Nuclear Information System (INIS)

    Flick, H.A.

    1993-01-01

    The new SINUPERM N System is developed for Neutron Monitoring in nuclear power plants. The development was started in 1989 (with the design specification) and will be finished in 1993 (with the qualification). The first built will be the nuclear power plant in Borselle (Netherlands). The design is based on a microprocessor system with a digital signal processor for calculations and signal filtering. The separation between analogue-input signals and digital processing enables for each detector type special input modules and standard output interfaces e.g. field - bus. The wide range of the Neutron Flux Density from 10 -2 cm -2 s -1 up to 10 8 cm -2 s -1 for the out-of-pile instrumentation and up to 10 14 cm -2 s -1 for the in-core-instrumentation will be covered by the SINUPERM N system. The requirements to be met by the SINUPERM N system are the IEEE 323, IEC 987 and the German standard KTA-3503 for safety systems. Other standards for instrumentation and control systems like IEC 801, IEC 1131 and IEC 68 for EMV, climatic and seismic requirements are also included in the hardware type test. The software requirement depends on the IEC 880 standard. (author). 3 figs

  13. Section for Standard and Patents - Standardization and Patents

    International Nuclear Information System (INIS)

    Wojtowicz, S.; Trechcinski, R.; Rybka, M.; Ryszkowska, A.; Wardaszko, J.

    1997-01-01

    Full text: The most important tasks of the Section in 1996 were: preparation of national standards and program of future work on standards for nuclear instrumentation and electronic equipment in nuclear engineering; organization of activities and participation in the meetings of the Commissions for Standardization No 173 Microprocessor Systems, No 266 Nuclear Instrumentation; giving opinions and expertises on national and international standards for equipment in nuclear engineering; cooperation with the Commission for Standardization No 246 Radiological Protection; control of inventiveness activity; The quality of the technical products is being improved by: a) selection of the proper types of interface systems, technical coordination and quality control; b) creation of standards at a high technical level; The Section works mainly for the Polish Committee for Standardization, the National Atomic Energy Agency, Association of Polish Electrical Engineers and Research Institutes in Poland. The activity of the Section is useful for all national institutions where backplane busses and nuclear electronic equipment is produced or used. The Section participates in the following international organizations: IEC (International Electrotechnical Commission) TC 45 (Nuclear Instrumentation); ISO/IEC Joint Technical Committee ISO/IEC JTCl SC26 (Microprocessor systems); ESONE (European Studies on Norms for Electronics); The section takes part in popularization of nuclear technology and instrumentation in the following ways: distribution of standards and technical documentation to national institutions dealing with nuclear apparatus; collecting and distributing technical information from international organizations (e.g. ESONE); organization of technical and scientific, national and international conferences (New Generation Nuclear Power Plants - September 96, QNX in Real World - January 96); participation in the technical conference organized by the Polish Committee for

  14. Qualification of cables to IEEE standards 323-1974 and 383-1974

    International Nuclear Information System (INIS)

    Hosticka, C.; Kingsbury, E.R.; Bruhin, A.C.

    1980-01-01

    Wire and Cable manufacturers generally qualify products for class IE application by envelope type testing to user specifications and environmental conditions recommended by IEEE Standards 323-1974 and 383-1974. The General Electric Wire and Cable Business Department recently completed two such qualification programs. Cable constructions tested were 600V control cables and 600 V, 2kV, and 15kV power cables insulated with flame resistant mineral filled crosslinked polyethylene. The 15kV samples included taped field splices. In the second test program, the steam pressure-temperature profile included a simulated main steam line break. Test specimens were wrapped on grounded mandrels and were electrically loaded throughout the simulated LOCA tests. After completion of environmental testing, samples were subjected to the IEEE 383 simulated post-LOCA test. 6 refs

  15. Qualification of cables to IEEE standards 323-1974 and 383-1974

    International Nuclear Information System (INIS)

    Hosticka, C.; Kingsbury, E.R.; Bruhin, A.C.

    1980-01-01

    Wire and Cable manufacturers generally qualify products for class IE application by envelope type testing to user specifications and environmental conditions recommended by IEEE Standards 323-1974 and 383-1974. The General Electric Wire and Cable Business Department recently completed two such qualification programs. Cable constructions tested were 600V control cables and 600 V, 2KV, and 15KV power cables insulated with flame resistant mineral filled crosslinked polyethylene. The 15KV samples included taped field splices. In the second test program, the steam pressure-temperature profile included a simulated main steam line break. Test specimens were wrapped on grounded mandrels and were electrically loaded throughout the simulated LOCA tests. After completion of environmental testing, samples were subjected to the IEEE 383 simulated post-LOCA test. 6 refs

  16. Standardization of Nuclear Instrumentation Applied in the NPP and in other nuclear installations

    International Nuclear Information System (INIS)

    Kusnowo, Arlinah; Darmawati, Suzie

    2002-01-01

    Nuclear power plant (NPP) and other nuclear installations have been recognized as applications needing very sophisticated technologies. One of technologies used in this all nuclear facilities is nuclear instrumentation. In order that NPP and other nuclear installations be operated safely, nuclear instrumentation requires standardization from design to its operation. Internationally, standardizations of nuclear instrumentation have been issued by IEC (International Electrotechnical Commission). Formulation of standard in nuclear instrumentation in IEC is carried out by Technical Committee (TC) 45. This paper describes briefly the standardization of nuclear instrumentation applied in Indonesia as Indonesian National Standard (SNI, Standard National Indonesia), standardization of nuclear instrumentation developed by TC 45, SC 45A, and SC 45B, as well as the possibility to adopt and apply those IEC standard in Indonesia

  17. Answering the request for emergency assistance worldwide. The Incident and Emergency Centre (IEC)

    International Nuclear Information System (INIS)

    2007-01-01

    In 2005, the IAEA announced the establishment of a fully integrated Incident and Emergency Centre (IEC). The functions of the IEC include coordinating prompt assistance to requesting States in the case of a nuclear security incident. As the global focal point for international preparedness, communication and response to nuclear and radiological incidents or emergencies irrespective of their cause, the IEC stands at the centre of coordinating effective and efficient activities worldwide. The IEC's work includes the evaluation of emergency plans and assistance in their development. The Centre also develops accident classifications based on plant conditions and supports effective communication between neighbouring countries. In addition, it develops various response procedures and facilitates national exercises on response to reactor emergencies. This includes training a broad range of IAEA staff to respond to emergencies as well as training of external experts. Response to incidents and emergencies can involve the exchange of information, provision of advice and/or the coordination of field response. In order to coordinate a global response, the IEC hosts a Response Assistance Network (RANET) under which Member States, Parties to the Emergency Conventions and relevant international organizations are able to register their response capabilities. This network aims to facilitate assistance in case of a nuclear or radiological incident or emergency in a timely and effective manner. An important component of the global emergency response system is the notification and reporting arrangements and systems operated by the IEC. The IEC operates systems that are reliable and secure. Member States, Non-Member States and international organizations have historically reported events and requests for assistance to the IAEA through the ENATOM arrangements using the ENAC web site, phone or fax. Under these arrangements, States have nominated Competent Authorities and National Warning

  18. Recent developments in methodology for dynamic qualification of nuclear plant equipment

    International Nuclear Information System (INIS)

    Kana, D.D.; Pomerening, D.J.

    1984-01-01

    Dynamic qualification of nuclear plant electrical and mechanical equipment is performed basically under guidelines given in IEEE Standards 323 and 344, and a variety of NRC regulatory guides. Over the last fifteen years qualification methodology prescribed by these documents has changed significantly as interpretations, equipment capability, and imagination of the qualification engineers have progressed. This progress has been sparked by concurrent NRC and industry sponsored research programs that have identified anomalies and developed new methodologies for resolving them. Revisions of the standards have only resulted after a lengthy debate of all such new information and subsequent judgment of its validity. The purpose of this paper is to review a variety of procedural improvements and developments in qualification methodology that are under current consideration as revisions to the standards. Many of the improvements and developments have resulted from recent research programs. All are very likely to appear in one type of standard or another in the near future

  19. Maturity index on reliability: covering non-technical aspects of IEC61508 reliability certification

    International Nuclear Information System (INIS)

    Brombacher, A.C.

    1999-01-01

    One of the more recent developments in the field of reliability and safety is the realisation that these aspects are not only a function of the product itself, but also of the organisation realising this product. A second development is a trend from an often predominantly qualitative analysis towards a quantitative analysis. In contrast to the (older) DIN 0801, the (more recent) IEC61508 requires, on product level, also a quantitative analysis and, on organisational level, an assessment of the lifecycle of a product by analysing the (maturity of the) relevant business processes (DIN V VDE 0801. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, 1990; DIN V 0801. Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, 1994; DIN V VDE 0801 A1. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Aenderung A1, 1994; IEC 61508 Functional Safety of electrical/electronic/programmable electronic safety-related systems, draft 4.0, 1997). The IEC standard 61508 covers: (i) technical aspects, both on a quantitative and a qualitative level; (ii) organisational aspects, both on aspects of maturity of business processes (quantitative) and on aspects of the definition and application of procedures (qualitative). This paper shows the necessity for an analysis on all aspects in a safety certification process, and presents an overview of the available tools and techniques for the various quadrants. As methods and tools for especially quadrant C are currently unavailable, this paper will propose a method to assess and improve the maturity of an organisation on reliability management: the maturity index on reliability (MIR)

  20. Air kerma standardization for diagnostic radiology in a secondary standard laboratory

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Lopes, Ricardo T.

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Brazilian Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. The objective of this work was to implement the standardization of the air kerma for the unatenuated qualities (RQR) of IEC 61267 in the National Laboratory of Metrology of the Ionizing Radiations (LNMRI) of the Institute of Radiation Protection and Dosimetry (IRD). Technical procedures were developed together with uncertainty budget. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. (author)

  1. IEC fusion: The future power and propulsion system for space

    International Nuclear Information System (INIS)

    Hammond, Walter E.; Coventry, Matt; Miley, George H.; Nadler, Jon; Hanson, John; Hrbud, Ivana

    2000-01-01

    Rapid access to any point in the solar system requires advanced propulsion concepts that will provide extremely high specific impulse, low specific power, and a high thrust-to-power ratio. Inertial Electrostatic Confinement (IEC) fusion is one of many exciting concepts emerging through propulsion and power research in laboratories across the nation which will determine the future direction of space exploration. This is part of a series of papers that discuss different applications of the Inertial Electrostatic Confinement (IEC) fusion concept for both in-space and terrestrial use. IEC will enable tremendous advances in faster travel times within the solar system. The technology is currently under investigation for proof of concept and transitioning into the first prototype units for commercial applications. In addition to use in propulsion for space applications, terrestrial applications include desalinization plants, high energy neutron sources for radioisotope generation, high flux sources for medical applications, proton sources for specialized medical applications, and tritium production

  2. Development of Electro-Optical Standard Processes for Application

    Science.gov (United States)

    2011-11-01

    IEC - 17025 (Reference 1.11c). The 17025 standard, which is part of the ISO -9000 series and is more familiar to industry, replaced ISO Guide 25, which...Even if the EO/IR community elects to follow a path defined by ISO / IEC 17025 , the modified criteria should be considered as a starting point. (See... 17025 and its U.S. equivalent, ANSI/NCSL Z540.3-2006. ISO / IEC - 17025 differs significantly in organization, but contains very similar quality

  3. IGF-IEc expression is increased in secondary compared to primary foci in neuroendocrine neoplasms.

    Science.gov (United States)

    Alexandraki, Krystallenia I; Philippou, Anastassios; Boutzios, Georgios; Theohari, Irini; Koutsilieris, Michael; Delladetsima, Ioanna Kassiani; Kaltsas, Gregory A

    2017-10-03

    Different Insulin-like growth factor-I (IGF-I) mRNA transcripts are produced by alternative splicing and particularly the IGF-IEc isoform has been implicated in the development and/or progression of various types of cancer. In the present study, we examined the potential role of IGF-IEc expression as a new immunohistochemical marker of aggressiveness in neuroendocrine neoplasms (NENs). We utilized immunohistochemical analysis in tissue specimens of 47 patients with NENs, to evaluate the expression of IGF-IEc (%) and Ki-67 proliferation index (%). Specimens from patients with tumors of different tissue origin, of either primary or metastatic lesions and of different grade were examined. Cytoplasmic IGF-IEc staining was found in 23 specimens of NENs or NECs: 10 pancreatic, 4 small bowel, 3 gastric, 1 lung, 1 uterine and 4 poorly differentiated of unknown primary origin. Ki-67 and IGF-IEc expression was positively correlated in all the samples studied (r=0.31, p=0.03). IGF-1Ec expression was more prevalent in specimens originating from metastatic foci with high Ki-67 compared to primary sites with low Ki-67 expression (p=0.036). These findings suggest a possible role of IGF-IEc in NEN tumorigenesis and progression to metastases that could be used as an additional new marker of a more aggressive behavior and a potential drugable target.

  4. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    International Nuclear Information System (INIS)

    Voytchev, M.; Chiaro, P.; Radev, R.

    2006-01-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'

  5. Sophisticated Calculation of the 1oo4-architecture for Safety-related Systems Conforming to IEC61508

    International Nuclear Information System (INIS)

    Hayek, A; Al Bokhaiti, M; Schwarz, M H; Boercsoek, J

    2012-01-01

    With the publication and enforcement of the standard IEC 61508 of safety related systems, recent system architectures have been presented and evaluated. Among a number of techniques and measures to the evaluation of safety integrity level (SIL) for safety-related systems, several measures such as reliability block diagrams and Markov models are used to analyze the probability of failure on demand (PFD) and mean time to failure (MTTF) which conform to IEC 61508. The current paper deals with the quantitative analysis of the novel 1oo4-architecture (one out of four) presented in recent work. Therefore sophisticated calculations for the required parameters are introduced. The provided 1oo4-architecture represents an advanced safety architecture based on on-chip redundancy, which is 3-failure safe. This means that at least one of the four channels have to work correctly in order to trigger the safety function.

  6. Fiscal 1999 technical achievement report. Research and development project on the quickly effective international standards creation (Standardization of safety of light emitting diode or the like); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Hakko diode nado no anzensei ni kansuru hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Since radiation of a laser diode (LD) is quite different from that of a light emitting diode (LED), evaluating their safety under one and the same standard (criterion) is questionable. The International Electrotechnical Commission (IEC), however, treats them in the same way. For the remedy of such contradiction and for the clarification of difference between the two devices in terms of radiation characteristics, they were quantitatively measured for spatial coherence and further measured for coherence dependency of their beam diameters. Well-supported threshold levels were prepared and biological tests were conducted for proposing a revision of the LED safety standard (IEC). As for the safety of equipment with built-in infrared devices, a measurement method was prepared as IEC61913 and devices are already at the CVD (chemical vapor deposition) stage. The result will be placed before the IEC/TC76 committee for deliberation of IEC60825-1 revision. Furthermore, to establish alignment between IEC and ISO (International Standardization Organization) in terms of laser-aided measurement which is the foundation for such committee deliberation, an ISO/IEC international joint group was created, and a technical recommendation was compiled and presented to the two standardizing organizations. (NEDO)

  7. Hybrid Multi-Agent Control in Microgrids: Framework, Models and Implementations Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2014-12-01

    Full Text Available Operation control is a vital and complex issue for microgrids. The objective of this paper is to explore the practical means of applying decentralized control by using a multi agent system in actual microgrids and devices. This paper presents a hierarchical control framework (HCF consisting of local reaction control (LRC level, local decision control (LDC level, horizontal cooperation control (HCC level and vertical cooperation control (VCC level to meet different control requirements of a microgrid. Then, a hybrid multi-agent control model (HAM is proposed to implement HCF, and the properties, functionalities and operating rules of HAM are described. Furthermore, the paper elaborates on the implementation of HAM based on the IEC 61850 Standard, and proposes some new implementation methods, such as extended information models of IEC 61850 with agent communication language and bidirectional interaction mechanism of generic object oriented substation event (GOOSE communication. A hardware design and software system are proposed and the results of simulation and laboratory tests verify the effectiveness of the proposed strategies, models and implementations.

  8. Safety design guides for environmental qualification for CANDU 9

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    This safety design guide describes the safety philosophy and requirements for the environmental qualification of safety related systems and components for CANDU 9. The environmental qualification program identifies the equipments to be qualified and conditions to be used for qualification and provides comprehensive set of documentation to ensure that the qualification is complete and can be maintained for the life of the plant. A summary of the system, components and structures requiring environmental qualification is provided in the table for the guidance of the system design, and this table will be subject to change or confirmation by the environmental qualification program. Also, plant ares subject to harsh environment is provided in the figure. The change status of the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 1 tab., 5 figs. (Author) .new

  9. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    Energy Technology Data Exchange (ETDEWEB)

    Voytchev, M. [Institut de Radioprotection et de Surete Nucleaire (IRSN/DSU/SERAC/CTHIR), 91 - Gif sur Yvette (France); Chiaro, P. [Oak Ridge National Lab., TN (United States); Radev, R. [LLNL, Livermore, CA (United States)

    2006-07-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'.

  10. Plan de implementación de la ISO/IEC 27001:2013

    OpenAIRE

    Gorriti Aranguren, Iñaki

    2015-01-01

    En el desarrollo del proyecto se analizaron las directrices establecidas en la norma ISO/IEC 27001:2013, que especifica los requisitos necesarios para establecer, implantar, mantener y mejorar un SGSI mediante un proceso de mejora continua. In the development there were analyzed the directives established in the norm ISO/IEC27001:2013, which specifies the necessary requirements to establish, to implement, to support and to improve a SGSI by means of a process of constant improvement. En...

  11. Assessment of Information Security Management System based on ISO/IEC 27001:2013 On Subdirectorate of Data Center and Data Recovery Center in Ministry of Internal Affairs

    Science.gov (United States)

    Kurnianto, Ari; Isnanto, Rizal; Widodo, Aris Puji

    2018-02-01

    Information security is a problem effected business process of an organization, so it needs special concern. Information security assessment which is good and has international standard is done using Information Security Management System (ISMS) ISO/IEC 27001:2013. In this research, the high level assessment has been done using ISO/IEC 27001:2013 to observe the strength of information secuity in Ministry of Internal Affairs. The research explains about the assessment of information security management which is built using PHP. The input data use primary and secondary data which passed observation. The process gets maturity using the assessment of ISO/IEC 27001:2013. GAP Analysis observes the condition now a days and then to get recommendation and road map. The result of this research gets all of the information security process which has not been already good enough in Ministry of Internal Affairs, gives recommendation and road map to improve part of all information system being running. It indicates that ISO/IEC 27001:2013 is good used to rate maturity of information security management. As the next analyzation, this research use Clause and Annex in ISO/IEC 27001:2013 which is suitable with condition of Data Center and Data Recovery Center, so it gets optimum result and solving problem of the weakness information security.

  12. Selection, qualification and training of personnel for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This standard provides criteria for the selection, qualification and training of personnel for stationary nuclear power plants. Qualifications, responsibilities, and training of personnel in operating and support organizations appropriate for the safe and efficient operation of nuclear power plants are addressed

  13. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC; Establecimiento de las calidades de mamografia segun la norma IEC-61267 en el laboratorio de metrologia de radiaciones ionizantes del centro nacional de dosimetria (CND) y proceso de ampliacion de su acreditacion por ENAC

    Energy Technology Data Exchange (ETDEWEB)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-07-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  14. Comparison of EMI/RFI requirements to qualify the equipment for nuclear power plant. (RG 1.180, EPRI TR 102323, IEC 62003 and GB/T 11684)

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Tae Heon [Korea Testing Laboratory, Ansan (Korea, Republic of); Kim, Jong Seog [Research Institute of Korea Electric Power Corporation, Daejeon (Korea, Republic of); Seo, Jeong Ho; Cho, Kyoung Youn [Korea Electric Association, Seoul (Korea, Republic of)

    2011-05-15

    One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). In some reports for nuclear power plant (NPP), electromagnetic interference (EMI), radio frequency interference (RFI), and power surges have been identified as environmental conditions that can affect the performance of safety-related electrical equipment. There are mainly two reference guides for applying to qualify EMI/RFI requirements of the equipment used in a NPP: US NRC RG 1.180 and EPRI TR 102323. Recently, IEC published the standard for the equipment in the NPP, IEC 62003. This paper has compared the requirements of these, including comparing of the requirement of the Chinese national standard, GB/T 11684

  15. Comparison of EMI/RFI requirements to qualify the equipment for nuclear power plant. (RG 1.180, EPRI TR 102323, IEC 62003 and GB/T 11684)

    International Nuclear Information System (INIS)

    Jang, Tae Heon; Kim, Jong Seog; Seo, Jeong Ho; Cho, Kyoung Youn

    2011-01-01

    One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). In some reports for nuclear power plant (NPP), electromagnetic interference (EMI), radio frequency interference (RFI), and power surges have been identified as environmental conditions that can affect the performance of safety-related electrical equipment. There are mainly two reference guides for applying to qualify EMI/RFI requirements of the equipment used in a NPP: US NRC RG 1.180 and EPRI TR 102323. Recently, IEC published the standard for the equipment in the NPP, IEC 62003. This paper has compared the requirements of these, including comparing of the requirement of the Chinese national standard, GB/T 11684

  16. An analysis of the qualification criteria for small radioactive material shipping packages

    International Nuclear Information System (INIS)

    McClure, J.D.

    1983-05-01

    The RAM package design certification process has two important elements, testing and acceptance. These terms sound very similar but they have specific meanings. Qualification testing in the context of this study is the imposition of simulated accident test conditions upon the candidate package design. (Normal transportation environments may also be included.) Following qualification testing, the acceptance criteria provide the performance levels which, if demonstrated, indicate the ability of the RAM package to sustain the severity of the qualification testing sequence and yet maintain specified levels of package integrity. This study has used Severities of Transportation Accidents as a data base to examine the regulatory test criteria which are required to be met by small packages containing Type B quantities of radioactive material (RAM). The basic findings indicate that the present regulatory test standards provide significantly higher levels of protection for the surface transportation modes (truck, rail) than for RAM packages shipped by aircraft. It should also be noted that various risk assessment studies have shown that the risk to the public due to severe transport accidents by surface and air transport modes is very low. A key element in this study was the quantification of the severity of the transportation accident environment and the severity of the present qualification test standards (called qualification test standards in this document) so that a direct comparison could be made between them to assess the effectiveness of the existing qualification test standards. The manner in which this was accomplished is described

  17. An analysis of the qualification criteria for small radioactive material shipping packages

    Energy Technology Data Exchange (ETDEWEB)

    McClure, J.D.

    1983-05-01

    The RAM package design certification process has two important elements, testing and acceptance. These terms sound very similar but they have specific meanings. Qualification testing in the context of this study is the imposition of simulated accident test conditions upon the candidate package design. (Normal transportation environments may also be included.) Following qualification testing, the acceptance criteria provide the performance levels which, if demonstrated, indicate the ability of the RAM package to sustain the severity of the qualification testing sequence and yet maintain specified levels of package integrity. This study has used Severities of Transportation Accidents as a data base to examine the regulatory test criteria which are required to be met by small packages containing Type B quantities of radioactive material (RAM). The basic findings indicate that the present regulatory test standards provide significantly higher levels of protection for the surface transportation modes (truck, rail) than for RAM packages shipped by aircraft. It should also be noted that various risk assessment studies have shown that the risk to the public due to severe transport accidents by surface and air transport modes is very low. A key element in this study was the quantification of the severity of the transportation accident environment and the severity of the present qualification test standards (called qualification test standards in this document) so that a direct comparison could be made between them to assess the effectiveness of the existing qualification test standards. The manner in which this was accomplished is described.

  18. Standard practice for qualification of journeyman painters for application of coatings to steel surfaces of safety-related areas in nuclear facilities

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice provides a standard qualifying method for journeyman painters to verify their proficiency and ability to attain the required quality for application of specified coatings to steel surfaces in safety-related areas in a nuclear facility. Variations or simplifications of the practice set forth herein may be appropriate for special coating work such as maintenance or qualifications of equipment suppliers shop personnel. It is not the intent of this practice to mandate a singular basis for all qualifications. Evaluation of the journeyman painter being qualified in accordance with this practice, shall be by qualified agents as specified in 4.1. Reports shall be prepared as specified in Section 5, and certification as specified in Section 6. It is the intent of this practice to judge only the ability of the journeyman painter to apply specified coatings with the proper tools and equipment. This standard may involve hazardous materials, operations, and equipment

  19. IMPLEMENTATION OF SECURITY CONTROLS ACCORDING TO ISO/IEC 27002 IN A SMALL ORGANISATION

    Directory of Open Access Journals (Sweden)

    MATÚŠ HORVÁTH

    2009-12-01

    Full Text Available Information security should be today a key issue in any organization. With the implementation of information security management system (ISMS the organization can identify and reduce risks in this area. This the area of information security management covers a numbers of ISO / IEC 27000 standards, which are based on best practice solutions. However, smaller organizations are often discourages with the implementation of these systems, because of fear of high cost and complexity. Especially due to the fact that the standards does not strictly require implementation of all security controls it is possible to implement these systems in small-size organizations. In this article, we want to point on this fact through describing practical experience with ISMS implementation in small-size organization.

  20. Comparison of higher irradiance and black panel temperature UV backsheet exposures to field performance

    Science.gov (United States)

    Felder, Thomas C.; Gambogi, William J.; Phillips, Nancy; MacMaster, Steven W.; Yu, Bao-Ling; Trout, T. John

    2017-08-01

    The need for faster PV qualification tests that more accurately match field observations is leading to tests with higher acceleration levels, and validating the new tests through comparison to field data is an important step. We have tested and compared a wide panel of backsheets according to a proposed new backsheet UV exposure qualification standard from the International Electrotechnical Commission (IEC). Weathering Technical Standard IEC 62788-7-2 specifies higher irradiance and higher black panel temperature UV Xenon exposures. We tested PVF, PVDF, PET, PA and FEVEbased backsheets in glass laminates and simple backsheet coupons in UV exposure condition A3 (0.8W/sqmnm@340nm and 90° C BPT) We find mild yellowing with no mechanical loss in the original lower intensity ASTM G155 0.55 W/sqm-nm 70C BPT exposure condition. The new A3 exposures creates mechanical loss in sensitive backsheets, with no effect on known durable backsheets. Results from the new exposure are closer to field mechanical loss data.

  1. International Electrotechnical Commission standards and French material control standards

    International Nuclear Information System (INIS)

    Furet, J.; Weill, J.

    1978-01-01

    There are reported the international standards incorporated into the IEC Subcommitee 45 A (Nuclear Reactor Instrumentation) and the national standards elaborated by the Commissariat a l'Energie Atomique, CEA, Group of normalized control equipment, the degree of application of those being reported on the base design, call of bids and exploitation of nuclear power plants. (J.E. de C)

  2. Dynamic testing and qualification

    International Nuclear Information System (INIS)

    Kleine Tebbe, A.; Schmidt, G.; Theymann, W.

    1990-01-01

    The core structure of an HTR-plant consists of the side reflector, the bottom reflector, the top reflector and the pebble bed of spherical fuel elements. Dynamically this system is a many-body structure with non-linear force-deformation couplings. The integrity of the system under seismic loads is given by radially orientated spring packs. These spring packs must be stiff against earthquake loads, but must allow radial thermal movements. To verify the seismic safety of the system, scaled-down models were tested. The results of these tests were compared with those of analytical methods. The good-natured behaviour of the pebble-bed under seismic loads has been confirmed. Due to the granular structure of the non-regular packed pebble-bed, high damping occurs during seismic excitations. With increasing depth the damping ratio decreases because of restriction of movement. We are able to describe the seismic behaviour of the pebble-bed analytically. The one- and two-dimensional test configurations of the top reflector were used to analyse resonance and lumping effects. The experimental results were verified by the computer codes CRUNCH-1D AND CRUNCH-2D. The experimental investigations of the side reflector are underway. The results show a non-critical behaviour under horizontal excitations. Small rigid-body motions of single blocks are detected, but they do not cause any global ovalisations of the complete ring structure. Finite element calculations with contact and friction between the blocks show a close agreement with the experimental results. Seismic qualification of ground mounted electrical equipment is usually performed on the basis of codes like IEEE, IEC, KTA, etc. These standards give different possibilities of the excitation mode: sinusoidal excitation in every natural frequency (continuous or sine beat) or time history excitation which covers a prescribed required response spectrum. Recently performed tests are compared regarding the usefulness and severity

  3. Scaling of the Inertial Electrostatic Confinement (IEC) for near-term thrusters and future fusion propulsion

    International Nuclear Information System (INIS)

    Miley, G.; Bromley, B.; Jurczyk, B.; Stubbers, R.; DeMora, J.; Chacon, L.; Gu, Y.

    1998-01-01

    Inertial Electrostatic Confinement (IEC) is a unique approach to fusion and plasma energy systems that was conceptualized in the 1960s (Hirsch 1967) and has been the focus of recent development in the 1990s (Miley et al. 1995a). In the interests of space power and propulsion systems, conceptual rocket design studies (Bussard and Jameson 1994, Miley et al. 1995b) using the IEC have predicted excellent performance for a variety of space missions, since the power unit avoids the use of magnets and heavy drives resulting in a very high, specific impulse compared to other fusion systems. In their recent survey of prior conceptual design studies of fusion rockets, Williams and Borowski (1997) found that the Bussard IEC conceptual study (the ''QED'' engine) offered a thrust-to-weight ratio of 10 milli-g's, a factor of five higher than conventional magnetic confinement concepts and even slightly above anti-proton micro fission/fusion designs. Thus there is considerable motivation to study IEC concepts for eventual space applications. However, the physics feasibility of the IEC still requires experimental demonstration, and an expanded data base is needed to insure that a power unit can in fact be built

  4. Qualidade e educação superior: a norma de qualidade para a aprendizagem, educação e formação: ISO/IEC 19796-1 = Quality and Higher Education: the standard ISO/IEC 19796-1 for learning, education and training

    Directory of Open Access Journals (Sweden)

    Viebrantz, Rosalir

    2009-01-01

    Full Text Available Em 2005, uma nova norma de qualidade para a aprendizagem, educação e formação, a ISO/IEC 19796-1, foi publicada. O objetivo desta norma é orientar as organizações educacionais e desenvolver sistemas de qualidade e melhorar a qualidade dos seus processos, produtos e serviços. Este artigo busca entender a norma com base em conceitos de qualidade e na tendência à garantia da qualidade. A ISO/IEC é apresentada de forma sucinta, mostrando a metodologia e suas vantagens para as organizações educacionais. É ressaltado que a norma é um modelo de referência e necessita ser adaptada às necessidades e exigências de cada organização

  5. Seismic and environmental qualification of class IE equipment manufactured in Spain

    International Nuclear Information System (INIS)

    Gerini, P.; Lumbreras, A.; Naredo, F.

    1978-01-01

    Nuclear power plant instrumentation and control design is affected by several factors such as various plant operating conditions, transient response capability, safety requirements and changes in IEEE standards. Recent upgraded IEEE standards that call for Qualification of all Safety related I anc C equipment, namely IEEE 323 (Qualifying Class IE Electric Equipment for nuclear power generating stations) and its daughter Standard IEEE 344 (Recommended Practices for Seismic Qualification of Class IE Equipment for nuclear power generating stations) have been endorsed by the United States Nuclear Regulatory Commission through the issuance of corresponding Regulatory Guides. The author describes the Qualification requirements applicable to the Class IE I and C Components made in Spain for the different vintages of plants, and the programs implemented or plans established by Westinghouse to fulfill those requirements. (author)

  6. Seismic functional qualification of active mechanical and electrical components based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.

    1999-01-01

    The seismic testing for qualification of one sample of the NPP Kozloduy Control Panel type YKTC was carried out under Research Contract no: 8008/Rl, entitled: 'Seismic Functional Qualification of Active Mechanical and Electrical Components Based on Shaking Table Testing'. The tested specimen was selected by the Kozloduy NPP staff, Section 'TIA-2' (Technical Instrumentation and Automatics), however the seismic input parameters were selected by the NPP Kozloduy staff, Section HTS and SC (Hydro-Technical Systems and Engineering Structures). The applied methodology was developed by the Institute of Earthquake Engineering and Engineering Seismology staff. This report presents all relevant items related to the selected specimen seismic testing for seismic qualification such as: description of the tested specimen, mounting conditions on the shaking table, selection of seismic input parameters and creation of seismic excitations, description of the testing equipment, explanation of the applied methodology, 'on line' and 'off line' monitoring of the tested specimen, functioning capabilities, discussion of the results and their presentation and finally conclusions and recommendations. In this partial project report, two items are presented. The first item presents a review of the existing and used regulations for performing of the seismic and vibratory withstand testing of electro-mechanical equipment. The selection is made based on MEA, IEEE, IEC and former Soviet Union regulations. The second item presents the abstracts of all the tests performed at the Institute of Earthquake Engineering and Engineering Seismology in Skopje. The selected regulations, the experience of the Institute that has been gathered for the last seventeen years and some theoretical and experimental research will be the basis for further investigations for development of a synthesised methodology for seismic qualification of differently categorized equipment for nuclear power plants

  7. ISO/IEC 17025–2017 "New requirements to the competence of test and calibration laboratories"

    Directory of Open Access Journals (Sweden)

    Baranova P. O.

    2018-05-01

    Full Text Available due to the continuous improvement of the regulatory framework, there is a growing demand for laboratory centers that provide services in the field of testing. The relevance of the topic lies in the transition of laboratories to the new version of ISO/IEC 17025–2017 «General requirements for the competence of test and calibration laboratories». The article compares two versions of the standard, reveals differences and similarities. And changes in the gradation of changes are also highlighted.

  8. RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhanced safety and availability. IEC technical report of type 3. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The present material presents a CD+V draft report ''RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhance safety and availability'' prepared by the Joint IEC/IAEA team during 1993-1995. Experience has demonstrated the need to improve the safety instrumentation of the RBMK type reactors using well proven modern technology. The working group identified the upgrades and changes of the highest priority based on the evaluation of the RBMK systems and the events where the instrumentation was found to be inadequate for safe operation. The subjects discussed in this document were not selected on a systematic basis but were selected by the IEC and IAEA experts as considered to be appropriate to the activities of the IEC and for which technical experience was available. The items identified therefore do not reflect any ranking of the safety issues or any priority or impact on safety of any of the measures were they to be implemented. Many important safety issued and areas where physical measures are required to improve safety have been omitted and indeed not even acknowledged in this document. The recommendations presented in the document differ from those normally produced by the IEC in the form of standards as they are of a transitory nature and some have already been overtaken by the continuing process of improvements to plant safety. Figs and tabs

  9. Assessment of Information Security Management System based on ISO/IEC 27001:2013 On Subdirectorate of Data Center and Data Recovery Center in Ministry of Internal Affairs

    Directory of Open Access Journals (Sweden)

    Kurnianto Ari

    2018-01-01

    Full Text Available Information security is a problem effected business process of an organization, so it needs special concern. Information security assessment which is good and has international standard is done using Information Security Management System (ISMS ISO/IEC 27001:2013. In this research, the high level assessment has been done using ISO/IEC 27001:2013 to observe the strength of information secuity in Ministry of Internal Affairs. The research explains about the assessment of information security management which is built using PHP. The input data use primary and secondary data which passed observation. The process gets maturity using the assessment of ISO/IEC 27001:2013. GAP Analysis observes the condition now a days and then to get recommendation and road map. The result of this research gets all of the information security process which has not been already good enough in Ministry of Internal Affairs, gives recommendation and road map to improve part of all information system being running. It indicates that ISO/IEC 27001:2013 is good used to rate maturity of information security management. As the next analyzation, this research use Clause and Annex in ISO/IEC 27001:2013 which is suitable with condition of Data Center and Data Recovery Center, so it gets optimum result and solving problem of the weakness information security.

  10. Direct energy conversion for IEC fusion for space applications

    International Nuclear Information System (INIS)

    Momota, Hiromu; Nadler, Jon; Miley, George H.

    2000-08-01

    The paper describes a concept of extracting fusion power from D- 3 He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates low energy ions and electron from the 14.7 MeV fusion protons and then converts their energy into electricity. In the traveling wave direct energy converter, fusion protons are modulated to form bunches. It couples with a transmission line to couple AC power out. The overall conversion efficiency of this system, combined with E- 3 He IEC cores, is estimated as high as 60%. (author)

  11. Direct energy conversion for IEC fusion for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Momota, Hiromu; Nadler, Jon [National Inst. for Fusion Science, Toki, Gifu (Japan); Miley, George H. [Fusion Studies Laboratory, Urbana, IL (United States)

    2000-08-01

    The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates low energy ions and electron from the 14.7 MeV fusion protons and then converts their energy into electricity. In the traveling wave direct energy converter, fusion protons are modulated to form bunches. It couples with a transmission line to couple AC power out. The overall conversion efficiency of this system, combined with E-{sup 3}He IEC cores, is estimated as high as 60%. (author)

  12. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2005-01-01

    Full text: Individual monitoring services in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonization existing in individual monitoring practices in Europe has been achieved mainly thank to documents as standards or international recommendations, which with a different weight, represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonization is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). If used for approval, passing one will not necessarily mean passing all. Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not itself assure that dose results are reliable. This might apply only to ISO/IEC17025 'quality' standard, which represents the best available tool for the quality of laboratory work and somehow include all technical and management requirements. When accredited according to ISO/IEC17025, an Individual Monitoring Service (IMS) fulfils standards. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonization of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. A standard, unlike a textbook or technical publication, does not cover the experience and opinion of one or few individuals only, but the consensus of the entire scientific and technical community concerned. Most of the standards applicable to individual monitoring are published by IEC or ISO, or both together. However, it has to be kept in mind that ISO and IEC standards, for example, are meant for manufactures and industry, which do not

  13. The status of Korean nuclear codes and standards

    International Nuclear Information System (INIS)

    Namha Kim; Jong-Hae Kim

    2005-01-01

    Korea Electric Power Industry Code (KEPIC), a set of integrated standards applicable to the design, construction and operation of electric power facilities including nuclear power plants, has been developed on the basis of referring to the prevailing U.S. codes and standards which had been applied to the electric power facilities in Korea. Being the developing and managing organization of KEPIC, Korea Electric Association (KEA) published its first edition in 1995, the second in 200,0 and is expected to publish the 2005 edition. KEPIC was applied to the construction of Ulchin Nuclear Units 5 and 6 in 1997, and will be applicable to the construction of forthcoming nuclear power plants in Korea. Along with the effectuation of the Agreement on Technical Barriers to Trade (TBT) in 1995, the international trend related to codes and standards is changing rapidly. The KEA is, therefore, making its utmost efforts so as for KEPIC to keep abreast with the changing environment in international arena. KEA notified ISO/IEC Information Centre of its acceptance of the Code of Good Practice in the Agreement on TBT. The 2005 KEPIC edition will be retrofitted according to the ISO/IEC Guide 21- Adoption of International Standards as regional or national standards. KEA's efforts will help KEPIC correspond with international standards such as ISO/IEC standards, and internationally recognized standards such as ASME codes and standards. (authors)

  14. Mutual Recogniton of Professional Qualifications

    DEFF Research Database (Denmark)

    Enemark, Stig; Plimmer, Francis

    The publication aims to review the concept of mutual recognition of qualifications within the world wide surveying community, and to develop a framework for the introduction of standards of global professional competence in this area. The publication also includes a number of case studies from...

  15. EXPERIMENTAL RESEARCHES OF ELECTRO-THERMAL RESISTIBILITY OF SEND-OFFS AND CABLES TO ACTION RATIONED ON THE INTERNATIONAL STANDARD OF IEC 62305-1-2010 OF APERIODIC IMPULSE OF CURRENT OF ARTIFICIAL LIGHTNING

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2016-03-01

    Full Text Available Purpose. Experimental researches of electro-thermal resistibility of cable-explorer products, applied in the power electric circuits of objects of electric-power industry, to action on its copper and aluminum parts bearings a current rationed on the International Standard of IEC 62305-1-2010 aperiodic impulse 10/350 μs of current of artificial lightning. Methodology. Electrophysics bases of technique of high tensions and high pulsed currents (HPC, and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring HPC in them. Results. Experimental a way the quantitative levels of maximal values maximum of possible and critical closenesses of aperiodic impulse 10/350 μs of current of artificial lightning with rationed on the international standard of IEC 62305-1-2010 peak-temporal parameters and admittances on them in copper (aluminum parts bearings a current of send-offs and cables with a polyethylene (PET and polyvinylchloride (PVCH isolation. Originality. First in world practice on the unique powerful high-voltage generator of HPC of artificial lightning experimental researches of resistibility to lightning of pre-production models of send-offs (cables are conducted with copper (aluminum tendons, PET and PVCH by an isolation, in-use in power electric circuits of electric-power industry objects. Practical value. The use in practice of protecting from lightning of the got results will allow substantially to promote functional and fire-prevention safety of engineering communications of objects of industrial electroenergy in the conditions of action on them of short shots of linear lightning.

  16. Round table discussion " Development of qualification framework in meteorology (TEMPUS QUALIMET)"

    Science.gov (United States)

    Bashmakova, I.; Belotserkovsky, A.; Karlin, L.; Petrosyan, A.; Serditova, N.; Zilitinkevich, S.

    2010-09-01

    The international consortium has started implementing a project aimed at the development of unified framework of qualifications in meteorology (QualiMet), setting a system of recognition and award of qualifications up to Doctoral level based on standards of knowledge, skill and competence acquired by learners is underway. The QualiMet has the following specific objectives: 1. To develop standards of knowledge, skills and competence for all qualifications up to Doctoral level needed in all possible occupations meteorology learner can undertake, by July 2011 2. To develop reciprocally recognized rubrics, criteria, methods and tools for assessing the compliance with the developed standards (quality assurance), by July 2012 3. To set the network of Centers of Excellence as the primary designer of sample education programs and learning experiences, both in brick-and-mortar and distant setting of delivery, leading to achievement of the developed standards, by December 2012 4. To set a system of mutual international recognition and award of qualifications in meteorology based on the developed procedures and establishment of self-regulatory public organization, by December 2012 The main beneficiaries of the project are: 1. Meteorology learners from the consortium countries. They will be able to make informed decisions about available qualification choices and progression options and provided an opportunity for students and graduates to participate in the system of international continuous education. 2. Meteorology employers from the consortium countries, They will be able to specify the level of knowledge, skill and competence required for occupational roles, evaluate qualifications presented, connect training and development with business needs. 3. Students and academic staff of all the consortium members, who will gain the increased mobility and exchange the fluxes of culturally and institutionally diversified lecturers and qualified specialists

  17. Nuclear EQ sourcebook: A compilation of documents for nuclear equipment qualification

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the nuclear power industry, environmental and seismic qualification of safety-related electrical and instrumentation equipment is collectively known as Equipment Qualification (EQ). Related technology, as well as regulatory requirements, have evolved rapidly during the last 15 years. For environmental qualification, what began in 1971 with one trial-use guide (IEEE Std 323-1971), now stands as a full complement of Nuclear Regulatory Commission (NRC) rules, guides and industry standards. In addition to the Institute of Electrical and Electronics Engineers (IEEE), the American Society of Mechanical Engineers (ASME) has also undertaken development of its own set of standards for use in qualifying safety-related mechanical equipment. To ensure that the original design and qualification is preserved, engineers need to select and use the correct set of NRC regulations, regulatory guides, industry standards, and generic correspondence. Given that the total number of these documents exceed 200, this task becomes resource intensive. This compilation is the first known publication available to serve the user-community need for a complete and exhaustive single source. Approximately 180 items (Bulletins, Federal Rules, Generic Letters, Notices, Regulatory Guides, IEEE Standards, IEEE Recommended Practices, and IEEE Guides) have been processed separately for inclusion on the data base

  18. Internal Audit Status For ISO 9001 And ISO/ IEC 17025 In Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Fazila Said; Nurul Huda Mudri; Nik Arlina Ali

    2012-01-01

    The development of MS ISO 9001 and MS ISO/ IEC 17025 in Malaysian Nuclear Agency is the basic step to enhance and improve the Quality Management System (QMS) for processes and laboratories that involve customers and suppliers in delivering products and services. The effectiveness of QMS is monitored by Research and Innovation Management Centre (RIMC) to ensure that all activities related to audit such as Internal Audit are well organized and implemented as documented in quality manual and procedure. This paper will discuss the status of internal audit for processes that implement MS ISO 9001 and laboratories that accredited with MS/ ISO IEC 17025 in year 2008, 2009 and 2010. The total of non-conformance (nc) and opportunity for improvement (ofi) for processes and laboratories and their numbers as per clause in MS ISO 9001 and MS ISO/ IEC 17025 are the indicators that reflects the effectiveness of QMS. Then, the total effectiveness of QMS for MS 9001 and MS ISO/ IEC 17025 is also determined via the number of conformance clause versus non-conformance clause for those three years. (author)

  19. T25 Qualification of old containers

    International Nuclear Information System (INIS)

    Hoerning, T.; Kasparek, E.M.; Voelzke, H.

    2013-01-01

    Radioactive waste for final disposal in the repository Konrad has to be packaged in licensed containers. The qualification of containers is performed according the respective standards and BfS requirements. The latter ones differ for different container types with respect to accident resistance based on the release behavior of the waste. Usually qualification of container types is performed before series production. The qualification of already produced containers (''old containers'') is significantly more complicated. The differences of quality assurance and materials properties of the older containers have to be evaluated. A main tool for this evaluation is the numerical re-calculation of accident scenarios for estimation of the safety margins. The validation of appropriate finite element models is available. Based on these date it might be possible to abandon additional drop tests with the existing old containers to prove the structural integrity.

  20. Scaling of the Inertial Electrostatic Confinement (IEC) for near-term thrusters and future fusion propulsion

    International Nuclear Information System (INIS)

    Miley, G.; Bromley, B.; Jurczyk, B.; Stubbers, R.; DeMora, J.; Chacon, L.; Gu, Y.

    1998-01-01

    Inertial Electrostatic Confinement (IEC) is a unique approach to fusion and plasma energy systems that was conceptualized in the 1960s (Hirsch 1967) and has been the focus of recent development in the 1990s (Miley et al. 1995a). In the interests of space power and propulsion systems, conceptual rocket design studies (Bussard and Jameson 1994, Miley et al. 1995b) using the IEC have predicted excellent performance for a variety of space missions, since the power unit avoids the use of magnets and heavy drives resulting in a very high, specific impulse compared to other fusion systems. In their recent survey of prior conceptual design studies of fusion rockets, Williams and Borowski (1997) found that the Bussard IEC conceptual study (the open-quotes QEDclose quotes engine) offered a thrust-to-weight ratio of 10 milli-g close-quote s, a factor of five higher than conventional magnetic confinement concepts and even slightly above anti-proton micro fission/fusion designs. Thus there is considerable motivation to study IEC concepts for eventual space applications. However, the physics feasibility of the IEC still requires experimental demonstration, and an expanded data base is needed to insure that a power unit can in fact be built. copyright 1998 American Institute of Physics

  1. Passive autocatalytic recombiner process features and new status of international qualification

    International Nuclear Information System (INIS)

    Eckardt, Bernd A.; Losch, Norbert

    2010-01-01

    New results of International PAR-Severe Accidents Qualification in frame of EC/IRSN Core Melt Program PHEBUS (with real molten core) are presented. Example Results: AREVA PAR Design: Best performance very fast start-up • highest efficiency absolutely constant hydrogen depletion rates. Others: Some industrial competitors failed. This enveloping real severe accident tests represents the new international PAR qualification standard and finalized the PAR qualification successfully. The design features supports PAR Dual function

  2. The challenge of Ciemat internal dosimetry service for accreditation according to ISO/IEC 17025 standard, for in vivo and in vitro monitoring and dose assessment of internal exposures

    International Nuclear Information System (INIS)

    Lopez, M.A.; Martin, R.; Hernandez, C.; Navarro, J.F.; Navarro, T.; Perez, B.; Sierra, I.

    2016-01-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. CIEMAT Internal Dosimetry Service (IDS) has developed and implemented a quality system based on ISO/IEC 17025 to ensure compliance with the general requirements of this reference standard. The development of documentary support according to this quality system permitted to standardise the systematic activities performed within the whole body counter and in vitro bioassay laboratories as well as the procedures carried out by qualified staff in charge of internal dose assessment. There was no previous experience in the accreditation of other internal dosimetry services in Spain. Then, requirements from the national regulatory body (Nuclear Safety Council, CSN) and national accreditation entity (ENAC) have been considered. The main concerns were to guarantee the traceability in the whole process and to avoid possible charge of interpretation or subjectivity in the methodology of dose assessment due to intakes of radionuclides when calculating from monitoring data. All the related international standards dealing with internal dosimetry were taken into account: ISO 28218 'Performance criteria for radiobioassay', ISO 27048 'Dose Assessment for the

  3. Instructor qualification for radiation safety training at a national laboratory

    International Nuclear Information System (INIS)

    Trinoskey, P.A.

    1994-10-01

    Prior to 1993, Health Physics Training (HPT) was conducted by the Lawrence Livermore National Laboratory (LLNL) health physics group. The job requirements specified a Masters Degree and experience. In fact, the majority of Health Physicists in the group were certified by the American Board of Health Physics. Under those circumstances, it was assumed that individuals in the group were technically qualified and the HPT instructor qualification stated that. In late 1993, the Health Physics Group at the LLNL was restructured and the training function was assigned to the training group. Additional requirements for training were mandated by the Department of Energy (DOE), which would necessitate increasing the existing training staff. With the need to hire, and the policy of reassignment of employees during downsizing, it was imperative that formal qualification standards be developed for technical knowledge. Qualification standards were in place for instructional capability. In drafting the new training qualifications for instructors, the requirements of a Certified Health Physicists had to be modified due to supply and demand. Additionally, for many of the performance-based training courses, registration by the National Registry of Radiation Protection Technologists is more desirable. Flexibility in qualification requirements has been incorporated to meet the reality of ongoing training and the compensation for desirable skills of individuals who may not meet all the criteria. The qualification requirements for an instructor rely on entry-level requirements and emphasis on goals (preferred) and continuing development of technical and instructional capabilities

  4. Similarity principles for equipment qualification by experience

    International Nuclear Information System (INIS)

    Kana, D.D.; Pomerening, D.J.

    1988-07-01

    A methodology is developed for seismic qualification of nuclear plant equipment by applying similarity principles to existing experience data. Experience data are available from previous qualifications by analysis or testing, or from actual earthquake events. Similarity principles are defined in terms of excitation, equipment physical characteristics, and equipment response. Physical similarity is further defined in terms of a critical transfer function for response at a location on a primary structure, whose response can be assumed directly related to ultimate fragility of the item under elevated levels of excitation. Procedures are developed for combining experience data into composite specifications for qualification of equipment that can be shown to be physically similar to the reference equipment. Other procedures are developed for extending qualifications beyond the original specifications under certain conditions. Some examples for application of the procedures and verification of them are given for certain cases that can be approximated by a two degree of freedom simple primary/secondary system. Other examples are based on use of actual test data available from previous qualifications. Relationships of the developments with other previously-published methods are discussed. The developments are intended to elaborate on the rather broad revised guidelines developed by the IEEE 344 Standards Committee for equipment qualification in new nuclear plants. However, the results also contribute to filling a gap that exists between the IEEE 344 methodology and that previously developed by the Seismic Qualification Utilities Group. The relationship of the results to safety margin methodology is also discussed. (author)

  5. Economies of using seismic experience data qualification methods at Department of Energy facilities

    International Nuclear Information System (INIS)

    Loceff, F.; Antaki, G.; Goen, L.

    1995-01-01

    This paper summarizes the implementation of the seismic qualification of existing equipment using experience data techniques. The emphasis is on the economies of this approach compared with standard qualification methods of analysis and testing or replacement with qualified equipment. Seismic qualification of existing equipment using experience data is a technical necessity and is the most economically attractive of the options. Representative costs for seismic qualification at two facilities show costs are substantially lower than the costs for qualification using conventional methods. Because of the experience to date, the authors recommend that the Department of Energy continue to sponsor the Existing Facilities Program for applying qualification using experience data techniques at DOE facilities

  6. Standard guide for the selection, training and qualification of nondestructive assay (NDA) personnel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide contains good practices for the selection, training, qualification, and professional development of personnel performing analysis, calibration, physical measurements, or data review using nondestructive assay equipment, methods, results, or techniques. The guide also covers NDA personnel involved with NDA equipment setup, selection, diagnosis, troubleshooting, or repair. Selection, training, and qualification programs based on this guide are intended to provide assurance that NDA personnel are qualified to perform their jobs competently. This guide presents a series of options but does not recommend a specific course of action.

  7. Qualification criteria verification for aisi-4340 steel suspension lug

    International Nuclear Information System (INIS)

    Riaz, M.A.; Alam, M.

    2005-01-01

    All external loads carried underneath an aircraft are mounted onto it through mechanism generally known as suspension system. The externally mounted attachments like bombs, missiles and fuel tanks etc. experience enormous aerodynamic and inertial forces in the flights. These forces are transferred to the interface point of suspension system, known as 'Suspension Lug'. Thus lugs are considered critical component and have extremely stringent qualification criteria standards used in the aviation industry in USA, Europe, Russia, etc. Different standards prevail in different parts of the world about qualification and testing of these lugs. As Pakistan is entering into aviation industry, therefore there is a need to fulfill the requirements of these standards, to suit Pakistani environment. The suspension lug under study is 2000 Ibs. load class made from AISI-4340 Steel having good mechanical properties as per required standard. The manufacturing processes included forging, machining and vacuum heat treatment. The prototypes of suspension lugs were manufactured in the local industry and subjected to the required mechanical tests such as tensile testing at 5 to 35 degree angles. Impact testing at cryogenic temperatures of -50 to -70 degree C, and breaking load testing were performed. The acceptable results were obtained and mechanical testing for qualification of lugs was finalized and standardized. The options were compared with practical viability, utilization of product and cost effectiveness. (author)

  8. Qualification of electrical equipment. A United States nuclear system supplier perspective

    International Nuclear Information System (INIS)

    Jordan, W.G.

    1978-01-01

    At Westinghouse Pressurized Water Reactor Systems Division (PWR-SD) qualification. of safety related electrical equipment can be segregated into three distinct generations: (1) the initial seismic and environmental qualification programs for electrical equipment (1969-1972); (2) the supplemental sismic and environmental qualification programs (1975-1977); and (3) the seismic and environmental qualification programs to meet IEEE-323-1974, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations''(1975). The latter two programs (in a licensing framework), as they are most current, with emphasis on electrical equipment (e.g. transmitters, rack mounted equipment) as opposed to electro-mechanical equipment (valve operators, pump motors) are reviewed. (author)

  9. Impact of pre-conditioning on the qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Isgro, J.R.

    1982-01-01

    This paper shares some recent experiences on the effects of preconditioning on the qualification of safety-related equipment not located in a harsh environment. Environmental and seismic qualification testing programs were conducted following the guidelines of IEEE 323-1974, IEEE 344-1975 and appropriate IEEE daughter standards, where available. The examples that follow will illustrate the degree of pre-conditioning of safety-related equipment qualified to the requirements of IEEE-323-1974, and its effect on the outcome of the qualification program

  10. 45 CFR 170.420 - Application.

    Science.gov (United States)

    2010-10-01

    ...-audit against all sections of ISO/IEC 17025:2005 (incorporated by reference in § 170.499), and the following: (i) A copy of the applicant's quality system document according to section 4.2.2 of ISO/IEC 17025... according to section 4.9.1 of ISO/IEC 17025:2005; and (iii) The qualifications of each of the applicant's...

  11. Implementation of IEC Generic Models of Type 1 Wind Turbine Generator in DIgSILENT PowerFactory

    Institute of Scientific and Technical Information of China (English)

    Haoran ZHAO; Qiuwei WU; Ioannis MARGARIS; Poul S(O)RENSEN

    2013-01-01

    The implementation method for the International Electrotechnical Commission (IEC) generic models of Type 1 wind turbine generator (WTG) in DIgSILENT PowerFactory is presented.The following items are described,i.e.model structure,model blocks and how to implement these blocks in the PowerFactory environment.Case studies under both normal and fault conditions are done with the implemented IEC generic models of Type 1 WTG,and dynamic responses are captured and analyzed.The case study results show that the IEC generic models of Type 1 WTG can correctly represent the performances of Type 1 WTG under both normal and fault conditions.

  12. Implementation plans for the Korean certified tumor registrar qualification system.

    Science.gov (United States)

    Boo, Yoo-Kyung; Lim, Hyun-Sook; Won, Young-Joo

    2014-01-01

    Cancer registration data is used to understand the nation's cancer burden, and to provide significant baseline data for cancer control efforts, as well as, research on cancer incidence, mortality, survival, and prevalence. A system that approves, assesses, and manages the qualification of specialists, responsible for performing cancer registration, has not been developed in Korea. This study presents ways to implement a certification system designed for the qualification of tumor registrars in Korea. Requirements for implementing a certified tumor registrar qualification system were determined by reviewing the system for establishing qualifications in Korea and the American qualification system via the National Cancer Registrars Association (NCRA). Moreover, a survey was conducted on Korean medical records administrators, who had taken the U.S. Certified Tumor Registrar (CTR) examination, in order to review their opinions regarding these requirements. This study verified the feasibility of a qualification examination based on the opinions of CTR specialists by determining the following: items, and the associated ratings, of the qualifications necessary to register individuals as certified tumor registrars in a private qualification system; status of human resources required for the examination or training processes; plans regarding the organization needed for management, and operation of qualifications, examination standards, subject areas, examination methods, examination qualifications, or education and training programs. The implementation of a certified tumor registrar qualification system will lead to enhanced job competency for specialists and a qualitative improvement of cancer registration data. It will also reliably foster human resources that will lay the groundwork needed to establish scientific and reasonable national cancer management policies.

  13. Measurement system for wind turbine acoustic noise assessment based on IEC standard and Qin′s model

    Institute of Scientific and Technical Information of China (English)

    Sun Lei; Qin Shuren; Bo Lin; Xu Liping; Stephan Joeckel

    2008-01-01

    A novel measurement system specially used in noise emission assessment and verification of wind turbine generator systems is presented that complies with specifications given in IEC 61400-11 to ensure the process consistency and accuracy. Theory elements of the calculation formula used for the sound power level of wind turbine have been discussed for the first time, and detailed calculation procedure of tonality and audibility integrating narrowband analysis and psychoacoustics is described. With a microphone and two PXI cards inserted into a PC, this system is designed in Qin′s model using VMIDS development system. Benefiting from the virtual instrument architecture, it′s the first time that all assessment process have been integrated into an organic whole, which gives full advantages of its efficiency, price, and facility. Mass experiments show that its assessment results accord with the ones given by MEASNET member.

  14. Standard Specification for Steel Blades Used with the Photovoltaic Module Surface Cut Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification specifies the recommended physical characteristics of the steel blades required for the surface cut test described in ANSI/UL 1703 (Section 24) and IEC 61730-2 (Paragraph 10.3). 1.2 ANSI/UL 1703 and IEC 61730-2 are standards for photovoltaic module safety testing. 1.3 This standard provides additional fabrication details for the surface cut test blades that are not provided in ANSI/UL 1703 or IEC 61730-2. Surface cut test blades that have out-of-tolerance corner radii or burrs are known to cause erroneous test results, either passes or failures. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. New conducted electrical weapons: Electrical safety relative to relevant standards.

    Science.gov (United States)

    Panescu, Dorin; Nerheim, Max; Kroll, Mark W; Brave, Michael A

    2017-07-01

    We have previously published about TASER ® conducted electrical weapons (CEW) compliance with international standards. CEWs deliver electrical pulses that can inhibit a person's neuromuscular control or temporarily incapacitate. An eXperimental Rotating-Field (XRF) waveform CEW and the X2 CEW are new 2-shot electrical weapon models designed to target a precise amount of delivered charge per pulse. They both can deploy 1 or 2 dart pairs, delivered by 2 separate cartridges. Additionally, the XRF controls delivery of incapacitating pulses over 4 field vectors, in a rotating sequence. As in our previous study, we were motivated by the need to understand the cardiac safety profile of these new CEWs. The goal of this paper is to analyze the nominal electrical outputs of TASER XRF and X2 CEWs in reference to provisions of all relevant international standards that specify safety requirements for electrical medical devices and electrical fences. Although these standards do not specifically mention CEWs, they are the closest electrical safety standards and hence give very relevant guidance. The outputs of several TASER XRF and X2 CEWs were measured under normal operating conditions. The measurements were compared against manufacturer specifications. CEWs electrical output parameters were reviewed against relevant safety requirements of UL 69, IEC 60335-2-76 Ed 2.1, IEC 60479-1, IEC 60479-2, AS/NZS 60479.1, AS/NZS 60479.2, IEC 60601-1 and BS EN 60601-1. Our study confirmed that the nominal electrical outputs of TASER XRF and X2 CEWs lie within safety bounds specified by relevant standards.

  16. Evaluation of a LiF:Mg,Ti thermoluminescent ring dosimeter according to the IEC 62387:2012 standards

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Edyelle L.B.; Barros, Vinícius S.M. de; Asfora, Viviane K.; Khoury, Helen J., E-mail: vsmdbarros@gmail.com [Unversidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2017-07-01

    This work shows results of type testing of a ring dosimeter system under new IEC 62387:2012. The personal dosimeter investigated in this work consists of a commercial one element plastic ring (RADOS) which contains an LiF:Mg,Ti. By applying requirements for statistical fluctuations and linearity, a minimum measurable dose in Hp(0.07) was established. Energy and angular dependence aided in determining energy correction factors and fading requirements were used to select the most appropriate preheat scheme. Type testing of passive radiation monitors performed in the Radiation Metrology Laboratory (LMRI-DEN/UFPE) of the Federal University of Pernambuco is a major step in Brazil for the independent evaluation of these dosimeters, currently not available in the country. (author)

  17. Approaches to the ISO/IEC 17025 accreditation for Pu and U accountancy analysis

    International Nuclear Information System (INIS)

    Okazaki, Hiro; Sumi, Mika; Abe, Katsuo; Sato, Mitsuhiro; Kageyama, Tomio

    2013-01-01

    The quality control section of Plutonium Fuel Development Center (PFDC) of Japan Atomic Energy Agency has been analyzing isotopic compositions by Mass Spectrometry as well as content by Isotope Dilution Mass Spectrometry (IDMS) of plutonium and uranium in nuclear materials. Along with establishing and managing the quality assurance system, ensuring the reliability of the analysis data is important. PFDC has been establishing the quality management system with ISO9001. ISO9001 consists of management requirements for quality system of organizations. While ISO/IEC 17025 consists of technical requirements for the competence of testing and calibration laboratories in addition to the management requirements. The quality control section addressed technical improvement to improve further reliability of analysis quality and we have accredited for ISO/IEC 17025 of isotopic compositions and content of plutonium and uranium in nuclear materials in March 2010. In this presentation, we report our approaches to the ISO/IEC 17025 accreditation and operation status. (author)

  18. Standard practice for qualification of journeyman painters for application of coatings to concrete surfaces of safety-related areas in nuclear facilities

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice provides a standard qualifying method for journeyman painters to verify their proficiency and ability to attain the required quality for application of specified coatings to concrete surfaces in safety-related areas in a nuclear facility. Variations or simplifications of the practice set forth herein may be appropriate for special coating work such as maintenance. It is not the intent of this practice to mandate a singular basis for all qualifications. Evaluation of the journeyman painter being qualified in accordance with this practice, shall be by qualified agents as specified in 4.1. Reports shall be prepared as specified in Section 5, and qualification as specified in Section 6. It is the intent of this practice to judge only the ability of the journeyman painter to apply specified coatings with the proper tools and equipment

  19. QA Programme of the TLD laboratory of the University of Costa Rica: IEC 61066 testing

    International Nuclear Information System (INIS)

    Mora, Patricia; Porras Chaverria, Mariela

    2008-01-01

    The Thermoluminescence Personal Dosimetry Laboratory of the University of Costa Rica provides dose measurements for around 90% of occupational radiation workers in the country. The assessment of doses to workers routinely exposed to external sources of radiation constitutes an integral part of any radiation protection programme and helps national authorities to ensure acceptably safe and satisfactory radiological conditions in workplaces. Harshaw Readers Model 4000 and 4500, dosimeter holders Type 8814 with TLD-100 in 0110 cards and loose TLD-100 chips are used to monitor personal dose equivalent, Hp(10) and Hp(0.07). In order to provide a reliable measurement of the operational quantities, a study was undertaken to verify the fulfillment of international requirements in our system (Model 4500 with cards) against the Thermoluminescence dosimetry systems for personal and environmental monitoring CEI IEC 61066 (1991 -2012). The type tests performed were nine in total: batch homogeneity, reproducibility, linearity, detection threshold, effect of climate conditions on reader, effect of light exposure on dosimeters, isotropy, transient voltage and dropping on dosimeters. A Cesium-137 source was used to irradiate the dosimeters and all procedures follow the indications given on the standard. Results showed that all IEC criteria were met by our Laboratory. Acceptable uncertainties were also studied under the ICRP recommendations; the analysis of the Trumpet Curve was done with satisfactory results (for doses above 0.5 mSv; quotient of measure to real dose less than 3%). For purposes of accreditation (ISO/IEC 17025:2005) and performance testing this work is very relevant since the University of Costa Rica wants to establish a solid individual monitoring programme for external radiation exposure that will provide users, registrants, licensees and regulatory bodies with information that can be used for the optimization of protection and dose limitation of Costa Rican workers

  20. Analysis of ISO/IEC 17025 for establishment of KOLAS (Korea Laboratory Accreditation Scheme) quality assurance system

    International Nuclear Information System (INIS)

    Nam, Ji Hee

    2000-12-01

    Besides one existent accredited lab, radioactive material chemical analysis lab, five test laboratories and two calibration labs are under plan to acquire the accreditation from KOLAS. But the current Quality Manual was developed according to ISO Guide 25 that was superceded by ISO/IEC 17025. Since it is tailored to the radioactive material chemical analysis lab, a number of requirements of the Manual are not applicable to the labs other than radioactive material chemical analysis lab. Through the analysis of ISO/IEC 17025, a model of quality system was established which is not only consistent with ISO/IEC 17025 but reflective of the KAERI's situation

  1. Qualification of RETRAN for simulator applications

    International Nuclear Information System (INIS)

    Harrison, J.F.

    1988-01-01

    The use of full-scope control room replica simulators increased substantially following the accident at Three Mile Island Unit 2. The technical capability required to represent severe events has been included, in varying degrees, in most simulators purchased since the TMI-2 accident. The ability of the instructor to create a large variety of combinations of malfunctions has also greatly expanded. The nuclear industry has developed a standard which establishes the minimum functional requirements for full-scope nuclear control room simulators used for operator training. This standard, ANSI/ANS-3.5, was first issued in 1981 and was reissued in 1985. A method for performing simulator qualification with best estimate analytical data has been proposed in EPRI NP-4243, Analytic Simulator Qualification Methodology. The idea presented there is to choose a set of transients which drive the simulator into all the system conditions (dynamic states) likely to be encountered during operator training. The key observable parameters for each state are compared to analyses performed with the best estimate analytical model The closeness of the comparison determines the fidelity of the simulator. The approach described in EPRI NP-4243 has been adapted for evaluating RETRAN's capability for use in simulator qualification. RETRAN analyses which compare the RETRAN results to plant or test facility data are evaluated with respect to the simulator test matrix documented in EPRI NP-4243

  2. 5 CFR 330.208 - Qualification requirements.

    Science.gov (United States)

    2010-01-01

    ... perform the duties and responsibilities of the position. (c) The sex of an individual may not be... qualified for a position if he or she: (1) Meets OPM-established or approved qualification standards and requirements for the position, including any minimum educational requirements, and any selection placement...

  3. Establishment Of Physicochemical Laboratory Of CANTI In Conformity With The Requirements Of ISO/IEC 17025:2005

    International Nuclear Information System (INIS)

    Pham Thi Hoang Ha; Phan Thi Luan; Le Thi Thanh Tam; Huynh Thai Kim Ngan; Duong Thi Bich Chi; Vo Thi Ngoc Cam; Ho Tran The Huu; Vo Thi Cuong; Tram Thi Khanh Quynh; Tran Tri Hai; To Ba Cuong

    2013-01-01

    23 testing methods have been established, compiled and issued in standard forms throughout the Project implementation. Besides, the Laboratory QA/QC system have been set up and put into operation from 01/09/2011. The Laboratory was assessed on 12-13/9/2012 by Bureau of Accreditation, Ministry of Science and Technology and has been certified to conform with the requirements of ISO/IEC 17025:2005 with the accreditation number VILAS 609 in pursuant to the Decision No. 365.2012/QD-VPCNCL dated on 20/12/2012. (author)

  4. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  5. Plan de implementación de un SGSI acorde a la norma ISO/IEC 27001:2005

    OpenAIRE

    Álvarez Verdugo, Joaquín

    2014-01-01

    Plan de implementación de un SGSI acorde a la norma ISO/IEC 27001:2005 en un organismo público municipal. Pla d'implementació d'un SGSI d'acord amb la norma ISO/IEC 27001:2005 en un organisme públic municipal. Master thesis for the ICT Security management program.

  6. Similarity principles for seismic qualification of equipment by experience data

    International Nuclear Information System (INIS)

    Kana, D.D.; Pomerening, D.J.

    1989-01-01

    A methodology is developed for seismic qualification of nuclear plant equipment by applying similarity principles to existing experience data. Experience data is that available from previous qualifications by analysis or testing, or from actual earthquake events. Similarity principles are defined in terms of excitation, equipment physical characteristics, and equipment response. Physical similarity is further defined in terms of a critical transfer function for response at a location on a primary structure, whose response can be assumed directly related to fragility of the item under elevated levels of excitation. Procedures are developed for combining experience data into composite specifications for qualification of equipment that can be shown to be physically similar to the reference equipment. Other procedures are developed for extending qualifications beyond the original specifications under certain conditions. Some examples for application and verification of the procedures are given for actual test data available from previous qualifications. The developments are intended to elaborate on the rather broad guidelines by the IEEE 344 Standards Committee for equipment qualification in new nuclear plants. The results also contribute to filling a gap that exists between the IEEE 344 methodology and that which was previously developed for equipment in existing plants by the Seismic Qualification Utilities Group. 10 refs., 9 figs., 1 tab

  7. HACIA LA EXTENSION DEL MÉTODO GRAY WATCH BASADO EN EL ESTÁNDAR DE CALIDAD ISO/IEC 25010 // TOWARDS THE EXTENSION OF THE GRAY WATCH METHOD BASED ON THE QUALITY STANDARD ISO/IEC 25010

    Directory of Open Access Journals (Sweden)

    Jorge Luis Pérez-Medina

    2012-06-01

    Full Text Available Talk about software quality implies the need to rely on parameters that should allow to establish the minimal levels that a product of this type must reach in order to be considered of quality. This paper aims to propose an extension of the method GRAY WATCH, specifically in the technical processes of Analysis and Design connecting the products obtained to the process of Implementation. The orientation of our proposal consists of using the standard of product quality ISO/IEC 25010, which establishes criteria for the specification of quality requirements of software products, their metrics and evaluation, and includes a quality model composed by characteristics and subcharacteristics. The result of this proposal, adds significant value to the extended method, Allowing to system analysts and Computer professionals to specify the precise activities to be performed to obtain quality requirements. To make this work we have supported our efforts in the Domain Engineering process based in Software Quality named InDoCaS as methodology for the definition of activities and products in the processes of Analysis, Design and Implementation of the Application.// RESUMEN: Hablar de calidad de software implica la necesidad de contar con parámetros que permitan establecer los niveles mínimos que un producto de este tipo debe alcanzar para que se considere de calidad. El presente articulo tiene como finalidad proponer una extension del método GRAY WATCH, especificamente en los procesos técnicos de análisis y diseño acoplando los productos obtenidos al proceso de implementación. La orientación de nuestra propuesta consiste en utilizar el estándar de calidad del producto ISO/IEC 25010, que establece criterios para la especificacion de requisitos de calidad de productos de software, sus métricas y su evaluación, e incluye un modelo de calidad compuesto por características y subcaracteristicas. El resultado de esta propuesta, agrega un valor importante al

  8. Inspector qualification guidelines

    International Nuclear Information System (INIS)

    Batty, A.C.; Van Binnebeek, J.J.; Ericsson, P.O.; Fisher, J.C.; Geiger, P.; Grandame, M.; Grimes, B.K.; Joode, A. de; Kaufer, B.; Kinoshita, M.; Klonk, H.; Koizumi, H.; Maeda, N.; Maqua, M.; Perez del Moral, C.; Roselli, F.; Warren, T.; Zimmerman, R.

    1994-07-01

    The OECD Nuclear Energy Agency Committee on Nuclear Regulatory Activities (CNRA) has a Working Group on Inspection Practices (WGIP). The WGIP provides a forum for the exchange of Information and experience on the safety Inspection practices of regulatory authorities In the CNRA member countries. A consistent qualification process and well defined level of training for all Inspectors who participate In the safety Inspections are needed to provide consistent Inspections and reliable Inspection results. The WGIP organized in 1992 a workshop on the conduct of inspections, inspector qualification and training, and shutdown inspections at the Technical Training Center of the US NRC in Chattanooga, Tennessee. In the connection of workshop the WGIP identified a need to develop guidance for inspector qualification which could be used as a model by those who are developing their qualification practices. The inspector qualification journals of US NRC provided a good basis for the work. The following inspector qualification guideline has been developed for guidance of qualification of a new inspector recruited to the regulatory body. This guideline has been developed for helping the supervisors and training officers to give the initial training and familiarization to the duties of a new inspector in a controlled manner. US NRC inspector qualification journals have been used to define the areas of attention. This guideline provides large flexibility for application in different type organizations. Large organizations can develop separate qualification journals for each inspector positions. Small regulatory bodies can develop individual training programmes by defining the necessary training topics on case by case basis. E.g. the guideline can be used to define the qualifications of contracted inspectors used in some countries. The appropriate part would apply. Annex 1 gives two examples how this guideline could be applied

  9. Inspector qualification guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Batty, A. C.; Van Binnebeek, J. J.; Ericsson, P. O.; Fisher, J. C.; Geiger, P.; Grandame, M.; Grimes, B. K.; Joode, A. de; Kaufer, B.; Kinoshita, M.; Klonk, H.; Koizumi, H.; Maeda, N.; Maqua, M.; Perez del Moral, C.; Roselli, F.; Warren, T.; Zimmerman, R.

    1994-07-15

    The OECD Nuclear Energy Agency Committee on Nuclear Regulatory Activities (CNRA) has a Working Group on Inspection Practices (WGIP). The WGIP provides a forum for the exchange of Information and experience on the safety Inspection practices of regulatory authorities In the CNRA member countries. A consistent qualification process and well defined level of training for all Inspectors who participate In the safety Inspections are needed to provide consistent Inspections and reliable Inspection results. The WGIP organized in 1992 a workshop on the conduct of inspections, inspector qualification and training, and shutdown inspections at the Technical Training Center of the US NRC in Chattanooga, Tennessee. In the connection of workshop the WGIP identified a need to develop guidance for inspector qualification which could be used as a model by those who are developing their qualification practices. The inspector qualification journals of US NRC provided a good basis for the work. The following inspector qualification guideline has been developed for guidance of qualification of a new inspector recruited to the regulatory body. This guideline has been developed for helping the supervisors and training officers to give the initial training and familiarization to the duties of a new inspector in a controlled manner. US NRC inspector qualification journals have been used to define the areas of attention. This guideline provides large flexibility for application in different type organizations. Large organizations can develop separate qualification journals for each inspector positions. Small regulatory bodies can develop individual training programmes by defining the necessary training topics on case by case basis. E.g. the guideline can be used to define the qualifications of contracted inspectors used in some countries. The appropriate part would apply. Annex 1 gives two examples how this guideline could be applied.

  10. Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D. C.; Wohlgemuth, J. H.

    2012-08-01

    Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

  11. DD fusion neutron production at UW-Madison using IEC devices

    Science.gov (United States)

    Fancher, Aaron; Michalak, Matt; Kulcinski, Gerald; Santarius, John; Bonomo, Richard

    2017-10-01

    An inertial electrostatic confinement (IEC) device using spherical, gridded electrodes at high voltage accelerates deuterium ions, allowing for neutrons to be produced within the device from DD fusion reactions. The effects of the device cathode voltage (30-170 kV), current (30-100 mA), and pressure (0.15-1.25 mTorr) on the neutron production rate have been measured. New high voltage capabilities have resulted in the achievement of a steady state neutron production rate of 3.3x108 n/s at 175 kV, 100 mA, and 1.0 mTorr of deuterium. Applications of IEC devices include the production of DD neutrons to detect chemical explosives and special nuclear materials using active interrogation methods. Research supported by US Dept. of Homeland Security Grant 2015-DN-077-AR1095 and the Grainger Foundation.

  12. Efficient IEC permanent-magnet motor (3 kW) - Final report; Effizienter IEC Permanent-Magnet-Motor (3 kW) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H. P.; Evequoz, B. [Haute Ecole valaisanne, Sion (Switzerland); Salathe, D. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland)

    2008-04-15

    Efficient permanent-magnet motors achieve in the area up to 100 kW a higher efficiency than induction machines (standard motors). A simple and fast energy saving option is the exchange of inefficient standard motors. The objective of this work is to install a 3 kW permanent-magnet motor in a standard IEC housing and the optimization of the design for high efficiency. Another objective is the development and the realization of an efficient variable speed control. The efficiency of the motor and the inverter with the control system must be demonstrated by tests. These tasks have been split between Circle Motor AG and the universities of applied sciences of Valais and Lucerne. Considering high-efficiency and low manufacturing cost, a brushless DC solution was adopted. This resulted in an optimum design of the motor and the control system realized with a three-phase rectifier, a buck converter with variable DC voltage, and a three-phase inverter feeding full positive and negative current to two of the legs simultaneously. The maximum measured efficiency is about 96.5% for the inverter and 92% for the motor. With the advantage of the variable speed operation, the efficiency of the realized 3 kW permanent magnet motor together with the control system is always higher than the efficiency of a measured class EFF1 induction motor, even with a direct connection to the grid. The permanent-magnet motor is also about 10 kg lighter. The cost calculation shows that the permanent-magnet motor can be competitive with the induction motor when speed control is desired. This is also the domain with the largest potential for energy savings from variable speed pumps, compressors, fans. (author)

  13. Qualification tests for PWR control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Yong; Jin, Choon Eon; Choi Suhn [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    It is necessary to perform the qualification test for the magnetic jack type CEDM to show the design compatibility because the CEDM is composed of many mechanical and electrical components complicatedly. ABB-CE performed various qualification tests during the development of the System80 CEDM to which Korea Standard Nuclear Plant (KSNP) CEDM referred. The qualification test for the CEDM is classified into the performance test and the dynamic test. The performance test is to verify operability of the CEDM, and the dynamic test is to find dynamic characteristics and to verify the structural integrity if the CEDM for the seismic accidents. Described in this report are the test requirements, the test facilities and the test methods for the performance and the dynamic qualification tests of the PWR magnetic jack type CEDM. The impacts of the design changes in the Korea Next Generation Reactor (KNGR) on the KSNP CEDM were analyzed to present the necessity for the tests. This report also proposes the facilities to perform the tests in KAERI including reasonable schedule for the tests. Attached to this report is the summary of qualification tests of System 80 CEDM performed by ABB-CE. 20 figs., 16 tabs., 21 refs. (Author) .new.

  14. Qualification tests for PWR control element drive mechanism

    International Nuclear Information System (INIS)

    Kim, In Yong; Jin, Choon Eon; Choi Suhn

    1996-01-01

    It is necessary to perform the qualification test for the magnetic jack type CEDM to show the design compatibility because the CEDM is composed of many mechanical and electrical components complicatedly. ABB-CE performed various qualification tests during the development of the System80 CEDM to which Korea Standard Nuclear Plant (KSNP) CEDM referred. The qualification test for the CEDM is classified into the performance test and the dynamic test. The performance test is to verify operability of the CEDM, and the dynamic test is to find dynamic characteristics and to verify the structural integrity if the CEDM for the seismic accidents. Described in this report are the test requirements, the test facilities and the test methods for the performance and the dynamic qualification tests of the PWR magnetic jack type CEDM. The impacts of the design changes in the Korea Next Generation Reactor (KNGR) on the KSNP CEDM were analyzed to present the necessity for the tests. This report also proposes the facilities to perform the tests in KAERI including reasonable schedule for the tests. Attached to this report is the summary of qualification tests of System 80 CEDM performed by ABB-CE. 20 figs., 16 tabs., 21 refs. (Author) .new

  15. Survey of NDT techniques, services, qualifications and certification of NDT personnel-preliminary results

    International Nuclear Information System (INIS)

    Aleta, C.R.; Kinilitan, V.E.; Lailo, R.M.

    1987-01-01

    This paper presented the results of a survey conducted to determine the profile of the NDT industry including its problems. A questionnaire designed in three parts 1) present practices on qualification and certification, 2) NDT equipment and 3) services and problems in NDT. Of the 36 firms contacted only 20 responded. Results indicated the following: a) most firms are engaged in four (4) main techniques, RT, UT, MT and PT. Only 2 indicated capability of ET. b) level III personnel are relatively few in number, c) most firms allow the ASNT recommendation as a basis for their qualifications and certification and are in favor of standardization of the qualification and certification process and supportive of a national center for training of NDT personnel and d) most firms perceived the lack of adequate repair/maintenance skills/facilities, followed by high cost of equipment and the lack of national standard for qualification and certification. (ELC)

  16. Draft I.E.C. standard for monitoring PWR internal structures; Projet de norme C.E.I. pour la surveillance des structures internes des REP

    Energy Technology Data Exchange (ETDEWEB)

    Trenty, A.

    1994-06-01

    EDF has proposed to the International Electrotechnical Commission a draft standard for monitoring the vessel internal structures of PWRs. The standard applies to systems used for monitoring the vibratory behavior of the internal structures of PWRs (core barrel, thermal shield, fuel assemblies) on the basis of neutron fluctuations observed outside the vessel as well as of vessel vibrations. It covers the systems characteristics and the monitoring procedures. It should facilitate standardization of monitoring and comparisons on an international level. This paper presents the main features of the draft standard: -principles of measurement: correlation between movements of internals and ex core neutron noise on the one hand, forced vibrations of the vessel on the other hand; -sampling and conditioning of the signals; -monitoring equipment and in particular spectral analysis device; -functions of the monitoring software used for spectral analysis, peak detection and calculation of structure displacement; -studies preliminary to setting up the monitoring (calculation of internal vibratory modes, defect simulation on mockup, qualification on reactor during hot test...); -monitoring procedures (periodicity of analysis and what to do in case of anomaly); -documentation necessary to the monitoring. A diagnostic procedure is given as an example. The draft standard, written in 1994, will be presented in Frankfurt (Germany) in February 1995. (author). 1 annexe.

  17. Qualification criteria to certify a package for air transport of plutonium

    International Nuclear Information System (INIS)

    1977-12-01

    The document describes qualification criteria developed by the U.S. Nuclear Regulatory Commission to certify a package for air transport of plutonium. Included in the document is a discussion of aircraft accident conditions and a summary of the technical basis for the qualification criteria. The criteria require prototype packages to be subjected to various individual and sequential tests that simulate the conditions produced in severe aircraft accidents. Specific post-test acceptance standards are prescribed for each of the three safety functions of a package. The qualification criteria also prescribe certain operational controls to be exercised during transport

  18. International standards for optical wireless communications: state-of-the-art and future directions

    Science.gov (United States)

    Marciniak, Marian

    2017-10-01

    As the number of active OWC installations is growing fast, the standards for compatibility of co-existing neighbouring systems are being developed. The paper addresses the Laser Safety (IEC standards), ITU-T Study Group 15 standards (G.640 Co-location longitudinally compatible interfaces for free space optical systems), ITU-Radiocommunication Sector standards (P.1817-1 Propagation data required for the design of terrestrial free-space optical links), and the IEEE Work in Progress - standardization activity on Visible Light Communications. International standards of FSO communications have been reviewed and discussed. ITU, IEC, and IEEE International standards for Free-Space Optical links have been reviewed. The system reliability and availability as well as security issues will be addressed as well in the talk.

  19. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  20. The spectra of the standard x-ray qualities used in STUK's Radiation Metrology Laboratory

    International Nuclear Information System (INIS)

    Tapiovaara, T.; Tapiovaara, M.; Siiskonen, T.; Hakanen, A.

    2008-02-01

    This report presents the fluence spectra of the standard x-radiation qualities used in the Radiation Dosimetry Laboratory of Radiation and Nuclear Safety Authority (STUK). The spectra were measured in August 2007. The radiation qualities characterised in the report are the ISO Narrow spectrum series (ISO N10-N200, ISO 4037-1:1996) and both of the RQR-spectrum series specified by the IEC (IEC 1267:1994 and IEC 61267:2005). The measurements were made using a high purity Ge-detector and the measured pulse height spectra were corrected to fluence spectra. Spectral characteristics were computed from the spectral data and compared to the requirements in the standards and to the values given in the quality manual of the laboratory. (orig.)

  1. The Emerging JBIG2 Standard

    DEFF Research Database (Denmark)

    Howard, P.; Kossentini, F.; Martins, Bo

    1998-01-01

    The Joint Bi-level Image Experts Group (JBIG), an international study group affiliated with ISO/IEC and ITU-T, is in the process of drafting a new standard for lossy and lossless compression of bi-level images. The new standard, informally referred to as JBIG2, will support model-based coding...... with imperceptible loss of quality. It is expected that JBIG2 will become an International Standard by 2000....

  2. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.

    Science.gov (United States)

    Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I

    2016-09-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Hybrid Qualifications

    DEFF Research Database (Denmark)

    Against the background of increasing qualification needs there is a growing awareness of the challenge to widen participation in processes of skill formation and competence development. At the same time, the issue of permeability between vocational education and training (VET) and general education...... has turned out as a major focus of European education and training policies and certainly is a crucial principle underlying the European Qualifications Framework (EQF). In this context, «hybrid qualifications» (HQ) may be seen as an interesting approach to tackle these challenges as they serve «two...

  4. Comparison of the Safety Critical Software V and V Requirements for the Research Reactor Instrumentation and Control System

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Sungmoon; Suh, Yong-Suk; Park, Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    This study was motivated by a research reactor project where the owner of the project and the equipment vendors are from two different standards frameworks. This paper reviews two major standards frameworks - NRC-IEEE and IAEA-IEC - and the software classification schemes as a background, then discuss the V and V issue. The purpose of this paper is by no means to solve the cross-standards-framework qualification issue, but, rather, is to remind the stakeholders of research reactor projects. V and V are also essential for the approval from regulatory bodies. As standards define or recommend consolidated engineering practices, methods, or criteria, V and V activities for software qualification are not exceptional. Within a standards framework, usually, the processes for the qualification of safety-critical software are well-established such that the safety is maximized while minimizing the compromises in software quality, safety, and reliability. When, however, multiple standards frameworks are involved in a research reactor project, it is difficult for equipment vendors to implement appropriate V and V activities as there is no unified view on this cross-standards-framework qualification issue yet. There are two major standards frameworks for safety-critical software development in nuclear industry. Unfortunately different safety classifications for software and thus different requirements for qualification are in place. What makes things worse is that (i) there are ambiguities in the standards and rooms for each stakeholders’ interpretation, and (ii) there is no one-to-one mapping between the associated V and V methods and activities. These may put the stakeholders of research reactor projects in trouble.

  5. Comparison of the Safety Critical Software V and V Requirements for the Research Reactor Instrumentation and Control System

    International Nuclear Information System (INIS)

    Joo, Sungmoon; Suh, Yong-Suk; Park, Cheol

    2016-01-01

    This study was motivated by a research reactor project where the owner of the project and the equipment vendors are from two different standards frameworks. This paper reviews two major standards frameworks - NRC-IEEE and IAEA-IEC - and the software classification schemes as a background, then discuss the V and V issue. The purpose of this paper is by no means to solve the cross-standards-framework qualification issue, but, rather, is to remind the stakeholders of research reactor projects. V and V are also essential for the approval from regulatory bodies. As standards define or recommend consolidated engineering practices, methods, or criteria, V and V activities for software qualification are not exceptional. Within a standards framework, usually, the processes for the qualification of safety-critical software are well-established such that the safety is maximized while minimizing the compromises in software quality, safety, and reliability. When, however, multiple standards frameworks are involved in a research reactor project, it is difficult for equipment vendors to implement appropriate V and V activities as there is no unified view on this cross-standards-framework qualification issue yet. There are two major standards frameworks for safety-critical software development in nuclear industry. Unfortunately different safety classifications for software and thus different requirements for qualification are in place. What makes things worse is that (i) there are ambiguities in the standards and rooms for each stakeholders’ interpretation, and (ii) there is no one-to-one mapping between the associated V and V methods and activities. These may put the stakeholders of research reactor projects in trouble

  6. DOE handbook: Guide to good practices for the selection, training, and qualification of shift supervisors

    International Nuclear Information System (INIS)

    1999-04-01

    This Department of Energy (DOE) handbook is approved for use by all DOE Components and their contractors. The Handbook incorporates editorial changes to DOE-STD-1061-93, ''Guide to Good Practices for the Selection, Training, and Qualification of shift Supervisors,'' and supersedes DOE-STD-1061-93. Technical content of this Handbook has not changed from the original technical standard. Changes are primarily editorial improvements, redesignation of the standard to a Handbook, and format changes to conform with current Technical Standards Program procedures. This guide, used in conjunction with a facility-specific job analysis, provides a framework for the selection, training, qualification, and professional development of reactor facility and non-reactor nuclear facility shift supervisors. Training and qualification programs based on this guide should provide assurance that shift supervisors perform their jobs safely and competently

  7. DOE handbook: Guide to good practices for the selection, training, and qualification of shift supervisors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-04-01

    This Department of Energy (DOE) handbook is approved for use by all DOE Components and their contractors. The Handbook incorporates editorial changes to DOE-STD-1061-93, ``Guide to Good Practices for the Selection, Training, and Qualification of shift Supervisors,`` and supersedes DOE-STD-1061-93. Technical content of this Handbook has not changed from the original technical standard. Changes are primarily editorial improvements, redesignation of the standard to a Handbook, and format changes to conform with current Technical Standards Program procedures. This guide, used in conjunction with a facility-specific job analysis, provides a framework for the selection, training, qualification, and professional development of reactor facility and non-reactor nuclear facility shift supervisors. Training and qualification programs based on this guide should provide assurance that shift supervisors perform their jobs safely and competently.

  8. IEC-TC88WG8 testing of rotor blades

    Energy Technology Data Exchange (ETDEWEB)

    Delft, D R.V. van [Delft Univ. of Technology, STEVIN Lab., Delft (Netherlands)

    1996-09-01

    In 1994 the TC88 of IEC installed a working group (WG8) to draft a guideline on blade testing. This paper gives a description of the task of the working group. Furthermore it gives a report of the progress of the work and summarizes the possible contents of the working group document on blade testing. (au)

  9. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra for Applications in Solar Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jessen, Wilko [German Aerospace Center (DLR); Wilbert, Stefan [German Aerospace Center (DLR); Gueymard, Christian A. [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-01

    Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches

  10. Qualification Practices in Nuclear Industry: Steam Generator Eddy Current Probe Qualification

    International Nuclear Information System (INIS)

    Vavrous, M.; Gracin, R.

    2010-01-01

    Through history of nuclear power plant operation, a large number of nuclear power plant forced outages related to tube failures occurred. It resulted with large amount of repair and outage costs, what initiated implementation of regulated practice of periodical tube examination and tube condition monitoring. Purpose of examinations is to detect existing or potential tube degradations that could affect tube integrity and therefore result in forced outages and unwanted costs related to emergency repair activities and loss of ability for electrical power production. With increased examination activities, additional information about steam generator tube condition became available and additional methods for ensuring tube integrity became available. As the number of examination solutions increased, need for validation and assessment of examination methods occurred. For that purpose, a large number of standards and guidelines with its requirements were implemented in nuclear industry regulatory requirements to ensure that adequately validated examinations are applied. With this purpose, qualification requirements for inspection activities were implemented with other requirements. With progress of technology, progress was also achieved in examination methods and more advanced examination methods and advanced inspection systems were developed. This advancement is accompanied by advancement in regulatory requirements regarding inspection and monitoring of tube integrity and condition. Ultimate goal of implementation of qualification processes and its requirements in all aspects of nuclear industry is to achieve minimal rate of forced outages, which would ensure maximum electrical power production capabilities and maximum optimization of operational costs while maintaining safe operation in accordance with environmental policies. This article will focus on qualification of steam generator eddy current bobbin probe.(author).

  11. Convergence Analysis of ISO/IEC 12207 and CMMI-DEV: Complementary Result from Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Javier Crisóstomo

    2017-12-01

    Full Text Available The organizations and people are demanding more and better software products and services, which implies adequate processes for its development. In the context of the software industry, there are two models, the CMMI-DEV and ISO/IEC 12207 that are influencing it. Though, they are evolving separately, recurrently they have been compared to determine its coverage (in both directions. In this study is analyzed the results of those comparisons (partials and completed to determine if the models ISO/IEC 12207 and CMMI-DEV converge at processes level. This study identified eight articles where the comparison is carried out between ISO/IEC 12207 and CMMI-DEV. The results show that technique most used is the mapping comparisons between the models and according to the analyzed studies is not possible to determine whether there is convergence in the time. However, we found some items and criterions for use in comparisons.

  12. Qualifications Frameworks and their conflicting social imaginaries of globalisation

    DEFF Research Database (Denmark)

    Sarauw, Laura Louise

    2013-01-01

    Critics of the European Bologna process often see it as a univocal standardization of higher education. By exploring how different qualifications frameworks currently project unlike imaginaries of and responses to globalisation, this article takes a different stance. As a key point, I argue...... that the well-known imaginary of globalisation as a change towards a more diverse and unforeseeable world, which calls for the development of flexible, lifelong learners with a broad knowledge base and strong democratic competencies that we find in the overarching qualifications framework of the Bologna process......, is a highly contested imaginary. In contrast, for example, the Danish qualifications framework of 2003 projects an imaginary of globalisation as a change towards a smaller and more predictable world, which enables a novel and more efficient alignment of the curriculum towards specific professional needs...

  13. Review of international standards related to the design for control rooms on nuclear power plants

    International Nuclear Information System (INIS)

    Kitamura, Masashi; Yoshikawa, Hidekazu; Fujita, Yushi

    2005-01-01

    The improvement of Human-Machine Interface (HMI) design for control rooms on nuclear power plants (NPP) has been accomplished world wide, especially after the TMI-2 accident. The design process and guidelines are standardized in IEC60964 and supplemental standards as international standard. However, technological update is required due to the increased use of computerized control and monitoring equipment and systems in control rooms on NPP in recent years. Standards are becoming more important for computerized control rooms because there is more freedom to design than conventional hardware based system. For computerized control rooms, standards for hardware and software of HMI systems should be also considered. Standards and guidelines for computerized control rooms on NPP have been developed recently in each body such as IEC, ISO, and IEEE etc. Therefore, reviewing these standards and guidelines related to control rooms design of NPP can be useful not only for revision of the international standards such as IEC60964, but also for users of the standards and guidelines. In this paper, we reviewed the international standards related to the design for control rooms, in the two aspects of HMI design and hardware and software design, considering the undergoing revision work and their application. (author)

  14. Software Quality Assurance and Controls Standard

    Science.gov (United States)

    2010-04-27

    dassurance a wor pro uc s an processes comply with predefined provisions and plans. • According to International Standard (IS) 12207 – of the 44...from document (plan) focus to process focus – Alignment with framework standard IS 12207 software life cycle (SLC) processes with exact...Books and P blications IEEE Software and Systems Engineering curriculum ABET u Certified Software Development Professional Standards ISO /IEC

  15. NFC based Equipment Qualification Management (NEQM) system preventing counterfeit and fraudulent item

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.K., E-mail: ckchang@kings.ac.kr [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of); Lee, K.J., E-mail: klee@khu.ac.kr [Kyung Hee Univ., Seoul (Korea, Republic of)

    2014-07-01

    Qualification of equipment essential to safety in nuclear power plants (NPPs) ensures its capability to perform designated safety functions on demand under postulated service conditions. However, a number of incidents identified by the NRC since 1980s catalysed the US nuclear industry to adopt standard precautions to guard against counterfeit items. The purpose of this paper is to suggest the NFC (Near Field Communication) based equipment qualification management system preventing counterfeit and fraudulent items. The NEQM (NFC based Equipment Qualification Management) system work with the support of legacy systems such as PMS (Procurement Management System) and FMS (Facility management System). (author)

  16. NFC based Equipment Qualification Management (NEQM) system preventing counterfeit and fraudulent item

    International Nuclear Information System (INIS)

    Chang, C.K.; Lee, K.J.

    2014-01-01

    Qualification of equipment essential to safety in nuclear power plants (NPPs) ensures its capability to perform designated safety functions on demand under postulated service conditions. However, a number of incidents identified by the NRC since 1980s catalysed the US nuclear industry to adopt standard precautions to guard against counterfeit items. The purpose of this paper is to suggest the NFC (Near Field Communication) based equipment qualification management system preventing counterfeit and fraudulent items. The NEQM (NFC based Equipment Qualification Management) system work with the support of legacy systems such as PMS (Procurement Management System) and FMS (Facility management System). (author)

  17. Australian Qualifications Framework Lower-Level Qualifications: Pathways to Where for Young People?

    Science.gov (United States)

    Stanwick, John

    2005-01-01

    This study investigates where certificate I and II qualifications lead young people aged 15-24 years in terms of employment and further study. A prime motivation for young people undertaking these qualifications is to facilitate transition into the labour market. These qualifications are aimed at developing basic vocational skills or preparatory…

  18. IEEE Std 650-1990: IEEE standard for qualification of Class 1E static battery chargers and inverters for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Methods for qualifying static battery chargers and inverters for Class 1E installations in a mild environment outside containment in nuclear power generating stations are described. The qualification methods set forth employ a combination of type testing and analysis, the latter including a justification of methods, theories, and assumptions used. These procedures meet the requirements of IEEE Std 323-1983, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations

  19. Generic test procedure for the qualification of a nuclear emergency generator

    International Nuclear Information System (INIS)

    Simonis, J.C.; Bowman, S.W.

    1985-01-01

    This paper describes the proposed analytical and experimental procedures for the qualification of the standby generators and exciters used in the Emergency Diesel Generator Systems in a nuclear power plant. The components which require qualification are identified through a failure mode analysis of the systems conducted using engineering drawings updated to include all field changes. The qualification of each component includes the margins given in IEEE Std. 323-1974, ''Qualifying Class 1E Equipment for Nuclear Power Generating Stations.'' These margins are combined with the plant specific data to define an enveloping set of environmental parameters. This set of enveloping parameters, plus margin, form the bases for the analysis or test qualification tasks. Proposed qualification of the composite electrical insulation systems used in the generator and exciter on the form or random wound coils is by traceable testing. However, before testing the thermal and radiation degradation data used in the design of the generator and exciter are evaluated to identify if these data are sufficiently traceable to eliminate the need for additional insulation tests. The required tests are guided by applicable standards

  20. Study on a Threat-Countermeasure Model Based on International Standard Information

    Directory of Open Access Journals (Sweden)

    Guillermo Horacio Ramirez Caceres

    2008-12-01

    Full Text Available Many international standards exist in the field of IT security. This research is based on the ISO/IEC 15408, 15446, 19791, 13335 and 17799 standards. In this paper, we propose a knowledge base comprising a threat countermeasure model based on international standards for identifying and specifying threats which affect IT environments. In addition, the proposed knowledge base system aims at fusing similar security control policies and objectives in order to create effective security guidelines for specific IT environments. As a result, a knowledge base of security objectives was developed on the basis of the relationships inside the standards as well as the relationships between different standards. In addition, a web application was developed which displays details about the most common threats to information systems, and for each threat presents a set of related security control policies from different international standards, including ISO/IEC 27002.

  1. Using ISO/IEC 12207 to analyze open source software development processes: an E-learning case study

    OpenAIRE

    Krishnamurthy, Aarthy; O'Connor, Rory

    2013-01-01

    peer-reviewed To date, there is no comprehensive study of open source software development process (OSSDP) carried out for open source (OS) e-learning systems. This paper presents the work which objectively analyzes the open source software development (OSSD) practices carried out by e-learning systems development communities and their results are represented using DEMO models. These results are compared using ISO/IEC 12207:2008. The comparison of DEMO models with ISO/IEC...

  2. Increased IGF-IEc expression and mechano-growth factor production in intestinal muscle of fibrostenotic Crohn's disease and smooth muscle hypertrophy.

    Science.gov (United States)

    Li, Chao; Vu, Kent; Hazelgrove, Krystina; Kuemmerle, John F

    2015-12-01

    The igf1 gene is alternatively spliced as IGF-IEa and IGF-IEc variants in humans. In fibrostenotic Crohn's disease, the fibrogenic cytokine TGF-β1 induces IGF-IEa expression and IGF-I production in intestinal smooth muscle and results in muscle hyperplasia and collagen I production that contribute to stricture formation. Mechano-growth factor (MGF) derived from IGF-IEc induces skeletal and cardiac muscle hypertrophy following stress. We hypothesized that increased IGF-IEc expression and MGF production mediated smooth muscle hypertrophy also characteristic of fibrostenotic Crohn's disease. IGF-IEc transcripts and MGF protein were increased in muscle cells isolated from fibrostenotic intestine under regulation by endogenous TGF-β1. Erk5 and MEF2C were phosphorylated in vivo in fibrostenotic muscle; both were phosphorylated and colocalized to nucleus in response to synthetic MGF in vitro. Smooth muscle-specific protein expression of α-smooth muscle actin, γ-smooth muscle actin, and smoothelin was increased in affected intestine. Erk5 inhibition or MEF2C siRNA blocked smooth muscle-specific gene expression and hypertrophy induced by synthetic MGF. Conditioned media of cultured fibrostenotic muscle induced muscle hypertrophy that was inhibited by immunoneutralization of endogenous MGF or pro-IGF-IEc. The results indicate that TGF-β1-dependent IGF-IEc expression and MGF production in patients with fibrostenotic Crohn's disease regulates smooth muscle cell hypertrophy a critical factor that contributes to intestinal stricture formation. Copyright © 2015 the American Physiological Society.

  3. Selecting safety standards for nuclear power plants

    International Nuclear Information System (INIS)

    1981-01-01

    , and these relations are getting stronger. ISO work results in technical standards with emphasis on industrial and contractual aspects, and they deal with standardized procedures, designs, materials, test methods, and terminology. This complementary nature of IAEA and ISO standards, and the close co-operation between the two organizations have recently been formally recognized in a Memorandum of Understanding between the two organizations. The International Electrotechnical Commission (IEC) develops standards which are of the same character as those of ISO. In the nuclear field IEC standards apply to such items as reactor instrumentation and equipment for radiation monitoring. In these areas the IEC and the IAEA are co-operating to achieve harmony in related work and to avoid duplication. Great care is also taken in IEC work to take into account national standards of leading industrialized countries in order to avoid conflicting requirements in the IEC and the national electric standards. The programme of the Commission of the European Communities (CEC) was also described during the Seminar. The CEC priorities in nuclear safety are now related to the accident at Three Mile Island in the United States. Current activities include emergency planning and co-operation between neighbouring countries. Efforts are being made to establish agreed intervention levels. Operational safety also receives great attention. A European reliability centre is envisaged, the goal being to put a reliability system into pilot operation in 1983. In operator training greater emphasis is put on training for abnormal situations and on adapting simulator training for this purpose. Finally, efforts are made to establish a consistent approach among the CEC member states with regard to siting nuclear facilities

  4. Aircraft impact qualification of RBMK systems and components. Technical report. Rev. 00, May 1999

    International Nuclear Information System (INIS)

    1999-01-01

    In the present report, the problem of qualification procedures of electrical equipment with respect to the dynamic excitation subsequent to an aircraft impact (ACC) on a Nuclear Power Plant (NPP) is approached, within the context of IAEA Benchmark on vulnerability of equipment and structures of RBMK-type NPP against the aircraft impact. After a short description of the main objectives of the work and the relevant area of concern (Chapter 1), the safety related equipment more commonly installed in a NPP are grouped in few classes, according to widely accepted classification criteria and the relevant failure modes are described (Chapter 2). Taking as reference a deeply studied RBMK reactor (Ignalina NPP), an overview of its main characteristics and of the equipment ensemble housed in is given in Chapter 3. An overview of the worldwide most used qualification standards for safety related equipment for NPPs is reported in Chapter 4, and a comparison of the practices used in Europe for the qualification of safety related electrical and I and C equipment is described with special attention to seismic and impact qualification (Chapter 5). In the hypothesis that the equipment to qualify against impact excitation has been already qualified against seismic excitation, the problems relevant to the different nature of earthquake and shock phenomena are listed, together with the main criteria to implement a procedure which, based on standardized shock pulses, could be applied for ACC qualification purposes (Chapter 6). Consequently, a possible ACC qualification procedure is outlined (Chapter 7) and the interface data (data coming from numerical analysis and seismic qualification, to be used for ACC qualification purposes) are listed (Chapter 8). Finally, the main conclusions of the work are described (Chapter 9). The main references are listed in Chapter 10. (author)

  5. Vertical Integration in factories using OPC-UA and IEC-61499

    Directory of Open Access Journals (Sweden)

    Marcelo V. García

    2017-02-01

    Full Text Available Nowadays, factory automation systems need to cope with very different challenges, such as big data, IIoT, etc. These challenges lead to a new generation of automation systems based on the so-called Cyber-Physical Production Systems (CPPS globally connected to form a flexible System of Cyber-Physical Production Systems (SoCPPS. CPPSs require acquisition of production system data and smart data processing to extract information to improve the overall system performance. To achieve that it is needed to bridge the gap between the control systems and higher layers. This paper discusses an approach to use the IEC 61499 function block concept to exchange data between plant floor and higher layers using an industrial standard like OPC UA. The OPC UA server offers subscription mechanisms, making possible the integration of several resources residing at plant floor. As it runs on embedded devices, the proposal makes possible to acquire plant information at low cost, enabling at the same time, a component-based design for enterprise plant floor control with independence of the hardware platform used

  6. Reaction Qualifications Revisited

    DEFF Research Database (Denmark)

    Lippert-Rasmussen, Kasper

    2009-01-01

      When, in a competitive sphere, people are selected on the basis of qualifications only, their chances of acquiring positions of advantage may seem to depend entirely upon their abilities, not discriminatory bias. However, if reaction qualifications - i.e. characteristics which contribute...... to a person's effectiveness by causing a favourable reaction in customers, co-workers etc. (for short: recipients) - are involved, this assumption is false. Building on work by Wertheimer, Mason, and Miller, this paper proposes an account of the reaction qualifications that count, from the point of view...... of merit. Specifically, it preserves symmetry between negative evaluations of antimeritocratic bases of selection and negative evaluations of qualifications rooted in comparable antimeritocratic reactions. So if employers should not select among applicants on the basis of their (the employers') racial...

  7. Calibration of kV measurers with the practical peak voltage (IEC 1676)

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.; Peres, Marcos A.L.; Ludwig, Jaime L.; Chernicharo, Carlos C.

    2002-01-01

    The IEC 1676 standard introduces a new quantity for the measurements of the high voltages applied to the X ray tubes used for diagnosis, the 'Practical Peak Voltage' (PPV). In order to start the introduction of this new quantity in Brazil the National Laboratory for Metrology of Ionizing Radiation has developed a procedure for calibrating measuring instruments in this quantity. This procedure is based in the same set up used for the calibration of the conventional kVp, which consists in a high voltage divider (Dynalyser III from Radcal Corporation), a fast analogue to digital conversion board and a data acquisition software. In order to evaluate this procedure a commercial kVp measure instrument that is able to measure PPV (Universal Diavolt from PTW) was calibrated and the results compared. This work presents a summary of the procedure developed and the results obtained with the comparison. (author)

  8. Importance of the European qualification frame (EQF) and its tools for radiation protection

    International Nuclear Information System (INIS)

    Schmitt-Hannig, Annemarie

    2013-01-01

    The harmonization of different radiation protection education and training systems in Europe and the mutual approval of the qualifications acquired abroad are discussed since years. Due to large national differences the mutual approval is usually based on case approaches instead of a standardized procedure. With the European qualification frame for life learning and EVCET (European credit system for vocational education and training) there are tools that could also be used in the sector of radiation protection education and training. The draft of the EURATOM basic safety standards (BSS) guideline includes the requirement of an approval of radiation protection officer certifications.

  9. Availability of systems with self-diagnostic components--applying Markov model to IEC 61508-6

    International Nuclear Information System (INIS)

    Zhang Tieling; Long, Wei; Sato, Yoshinobu

    2003-01-01

    Of all the techniques applicable to safety-related analyses, each one may be adaptable to some aspects of the system safety behavior. On the other hand, some of them can fit to analysis on one aspect of the system behavior concerning risk, but they do not always lead to the same results. Rouvroye and Brombacher made a comparison of these techniques and indicated that Markov and Enhanced Markov analysis techniques can cover most aspects of system's safety-related behavior. According to their conclusion, the Markov method is introduced to Part 6 of the standard IEC 61508 for quantitative analysis in this paper. The purpose is to present explanation in details for solutions given in the standard because there are not clear descriptions for many results and it is not easy for a safety engineer to find the clue. In addition, the down time t c1 shown in the standard is newly defined because it is the basis to get the results of average probability of failure on demand of system architectures and its meaning is not clearly explained. Through derivation, however, a discrepancy is found in the standard. From this point of view, new suggestions are proposed based on the results obtained

  10. Sustained qualification process for full scope nuclear power plant simulators

    International Nuclear Information System (INIS)

    Pirson, J.; Stubbe, E.; Vanhoenacker, L.

    1994-01-01

    In the past decade, simulator training for all nuclear power plant operators has evolved into a vital requirement. To assure a correct training, the simulator qualification process is an important issue not only for the initial validation but also following major simulator updates, which are necessary during the lifetime of the simulator. In order to avoid degradation of the simulator validated software, the modifications have to be introduced according to a rigorous methodology and a practical requalification process has to be applied. Such methodology has to be enforced at every phase of the simulator construction or updating process from plant data package constitution, over simulator software development to simulator response qualification. The initial qualification and requalification process is based on the 3 levels identified by the ANSI/ANS 3-5 standard for steady-state, operational transients and accident conditions. For the initial certification of the full scope simulators in Belgium, a practical qualification methodology has been applied, which has been adapted into a set of non regression tests for the requalification after major simulator updates. (orig.) (4 refs., 3 figs.)

  11. Environmental/dynamic mechanical equipment qualification and dynamic electrical equipment qualification program (EDQP)

    International Nuclear Information System (INIS)

    Hunter, J.A.

    1984-01-01

    Equipment qualification research is being conducted to investigate acceptable criteria, requirements, and methodologies for the dynamic (including seismic) and environmental qualification of mechanical equipment and for the dynamic (including seismic) qualification of electrical equipment. The program is organized into three elements: (1) General Research, (2) Environmental Research, and (3) Dynamic Research. This paper presents the highlights of the results to date in these three elements of the program

  12. How ISO/IEC 17799 can be used for base lining information assurance among entities using data mining for defense, homeland security, commercial, and other civilian/commercial domains

    Science.gov (United States)

    Perry, William G.

    2006-04-01

    One goal of database mining is to draw unique and valid perspectives from multiple data sources. Insights that are fashioned from closely-held data stores are likely to possess a high degree of reliability. The degree of information assurance comes into question, however, when external databases are accessed, combined and analyzed to form new perspectives. ISO/IEC 17799, Information technology-Security techniques-Code of practice for information security management, can be used to establish a higher level of information assurance among disparate entities using data mining in the defense, homeland security, commercial and other civilian/commercial domains. Organizations that meet ISO/IEC information security standards have identified and assessed risks, threats and vulnerabilities and have taken significant proactive steps to meet their unique security requirements. The ISO standards address twelve domains: risk assessment and treatment, security policy, organization of information security, asset management, human resources security, physical and environmental security, communications and operations management, access control, information systems acquisition, development and maintenance, information security incident management and business continuity management and compliance. Analysts can be relatively confident that if organizations are ISO 17799 compliant, a high degree of information assurance is likely to be a characteristic of the data sets being used. The reverse may be true. Extracting, fusing and drawing conclusions based upon databases with a low degree of information assurance may be wrought with all of the hazards that come from knowingly using bad data to make decisions. Using ISO/IEC 17799 as a baseline for information assurance can help mitigate these risks.

  13. PROBLEMS OF COMPETENCY-BASED ASSESSMENT OF APPLIED QUALIFICATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Efimova

    2017-01-01

    Full Text Available Introduction. The search of the unified tools of competences measurement of vocational training institutions graduates and identification of mechanisms of interrelation of these competences with requirements of professional standards imposed to workers of various levels are brought into focus in the context of formation of National system of qualifications of the Russian Federation, introduction of the Third-generation Federal State Educational Standards and transition of professional education to the modular, and competence-based model of the organization of training. The aim of the article is to justify the content, structure and technology of competency-based assessment, as a set of interrelated activities and regulated procedures performed on the basis of the standardized interdisciplinary evaluation materials. Methodology and research methods. The present investigation is based on systematic-activity and competency-based approaches, analysis, systematization, and generalization. Results. The place of competencies, as a part of educational outcomes of vocational education programs, is justified. Critical analysis of typical methodological solutions that are typical for the modern pedagogical practices of the competency-based assessment is performed. The content and organizational design of the process of competency-based assessment is described. Scientific novelty. The conceptual apparatus of competency-based assessment is supplemented with the «sub-competence» category - component of competence, which retains all of its properties due to human activities. Factors of objects choice and methods of assessment in identifying the professional competences are proved. Practical significance. Results of the study can be used by researchers involved with assessment procedures; methodologists and teachers of professional educational organizations, training institutes, independent centers of the qualifications evaluation for the organization of

  14. Maintaining and assessing extended 9 test methods in accordance with ISO/IEC 17025: 2005 for Isotopes Hydrology Laboratory

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Tran Khanh Minh; Vu Hoai

    2016-01-01

    The ISO/IEC 17025:2005 ''General requirements for the competence of testing and calibration laboratories'' is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technique and management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed and maintain a quality management system in accordance with ISO/IEC 17025:2005. In 2013, Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO/IEC 17025:2005 with VILAS 670 accredited code. Scope of recognition is analyzed 14 parameters: F"-, Cl"-, NO_2"-, NO_3"-, Br"-, PO_4"3"-, SO_4"2"-, Li"+, Na"+, NH_4"+, K"+, Mg"2"+, Ca"2"+ and "3H in water by ion chromatography and liquid scintillator counting method. The laboratory has successfully implemented the task of maintaining quality management systems conform to ISO/IEC 17025: 2005 and expanded the scope of accreditation by 9 parameters in water: pH, EC, TSS, TDS, DO, BOD5, pH, Fe and Mn in 2015. (author)

  15. Implementation and Practical Benefits of ISO/IEC 17025:2005 in a ...

    African Journals Online (AJOL)

    User

    support of top management. ... quality management system, based on ISO/IEC 17025:2005, is achievable if there ... services of an accredited laboratory knowing that their decisions will be .... reports containing test results of the methods included in the Accreditation ..... As XYZ Laboratory is a water and wastewater testing.

  16. Implementing service quality based on ISO/IEC 20000 a management guide

    CERN Document Server

    Kunas, Michael

    2012-01-01

    Potential customers will look for suppliers with ISO/IEC 20000 certification, seeking the reassurance it provides. This book will guide you through implementation and certification. Your streamlined management processes will enable you to offer first-class customer service at competitive prices. The impact on your profit margins is clear!

  17. Seismic qualification tests of fans of the NPP of Laguna Verde U-1 and U-2

    International Nuclear Information System (INIS)

    Jarvio C, G.; Garcia H, E. E.; Arguelles F, R.; Vela H, A.; Naranjo U, J. L.

    2013-10-01

    This work presents the results of the seismic qualification tests applied to the fans that will be installed in the control panels of the three divisions of the diesel generators of the nuclear power plant (NPP) of Laguna Verde, Unit-1 and Unit-2. This seismic qualification process of the fans was carried out using two specimens that were tested in the seismic table (vibrating) of the Engineering Institute of Universidad Nacional Autonoma de Mexico (UNAM), in accordance with the requirements of the standard IEEE 344-1975, to satisfy the established requirements of seismic qualification in the technical specifications and normative documents required by the nuclear standards, in order to demonstrate its application in the diesel generators Divisions I, II and III of the NPP. The seismic qualification tests were developed on specimens that were retired of the NPP of Laguna Verde recently with a service life of 7.75 years. (Author)

  18. English translations of German standards. Catalogue 1988. 24. ed.

    International Nuclear Information System (INIS)

    1988-01-01

    The catalogue contains a list of all currently available English translations of DIN standards, and of English translations of DIN handbooks, a numerical index, an alphabetical index, and an index of DIN EN, DIN IEC, DIN ISO standards, LN and VG standards. Some useful information on standards work in Germany and on the activities of DIN Deutsches Institut fuer Normung e.V. is given. (orig./HP)

  19. A Method for Remote Control of EV Charging by Modifying IEC61851 Compliant EVSE Based PWM Signal

    DEFF Research Database (Denmark)

    Pedersen, Anders Bro; Martinenas, Sergejus; Andersen, Peter Bach

    2016-01-01

    The Electric Vehicle (EV) has properties that can not only load but can elevate its value as a resource to the power system. An EV represents a high-power, fast-responding flexible demand unit, with an attached energy storage (battery) and the potential for bi-directional capabilities (V2G......). These properties can be used in a number of power and energy services, which can support power system operation while lowering the cost of EV ownership. Such services depend on the support from the communications technologies and standards that connect controllers and logic in the EVs with those in the charging...... for smart charging - to gain this ability by simply adhering to the widely supported IEC61851 standard. This paper describes the solution, demonstrates the implementation and discusses the potential it has for unlocking EV power- and energy services....

  20. REGULATION OF NATIONAL QUALIFICATIONS SYSTEMS

    Directory of Open Access Journals (Sweden)

    Anna A. Muravyeva

    2014-01-01

    Full Text Available The paper looks into the diverse aspects of qualifications system regulation, designed for balancing the supply and demand in the labor and educational service markets. Both the objects and mechanisms of such regulation are described. Special attention is given to institutions, involved in regulation of qualifications, and their jurisdiction. Another emphasis is on the industry-related regulation of qualifications which proved to be effective both on the national and European level. Such structures were first established on the national levels to regulate the qualifications and ensure their comparability and compatibility, given the economic globalization and growing labor and academic mobility. The author points out the role of the ministries of education and labor in maintaining a steady qualifications system, and outlines the positive experience of Great Britain using the industry councils for continuing development of qualifications system.

  1. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  2. DATA QUALIFICATION REPORT: DATA QUALIFICATION REPORT FOR 1991 1:1200 TOPOGRAPHIC MAPS FOR USE ON THE YUCCA MOUNTAIN PROJECT

    International Nuclear Information System (INIS)

    Knop, M.F.; Grant, T.A.; Bonisolli, R.W.

    2005-01-01

    This Data Qualification Report (DQR) is prepared in accordance with the provisions of AP-SIII.2Q, Rev. 0, ICN 3, Qualification of Unqualified Data and the Documentation of Rationale for Accepted Data and Data Qualification Plan for 1991 Topographic Maps 1:1200 Scale for use on the Yucca Mountain Project, DQP-WHS-CI-000001, Rev. 00 (BSC 2002a). This DQR presents an evaluation of a set of 90 topographic sheets at 1:1200 scale (and an associated electronic file) that covers an approximate 18 square mile area surrounding the proposed Yucca Mountain Project repository surface facilities location in Midway Valley, Nevada. These maps, that require qualification, are now being used to determine the physical characteristics of watershed sub-areas, interconnecting channels, and drainage channel cross-sections for hydrologic engineering studies of the north portal pad and vicinity. The result of this effort is to qualify one data tracking number (DTN) containing the electronic version of the mapping data. This DTN is: M09906COV98462.000. Coverage: TOP02FTS. The underlying quality assurance (QA) issue associated with these topographic maps is that the maps were originally designated as not for use in the design of items important to safety, waste isolation, and/or of programmatic importance. The maps were therefore generated outside the U.S. Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) QA program. Based on a comparison with corroborating information, this report concludes that the topographic maps are qualified. The comparison found that the mapping was reasonably accurate when compared with other mapping and survey data within the coverage area of the maps. Relative map accuracy was found to be very good and suitable for the hydrologic engineering studies being considered. Absolute accuracy is good but could not be demonstrated to comply with national map accuracy standards. Point locations that require high absolute accuracy should be

  3. Effect of patchouli alcohol on the regulation of heat shock-induced oxidative stress in IEC-6 cells.

    Science.gov (United States)

    Liu, Xiaoxi; Jiang, Linshu; Liu, Fenghua; Chen, Yuping; Xu, Lei; Li, Deyin; Ma, Yunfei; Li, Huanrong; Xu, Jianqin

    2016-08-01

    Purpose Patchouli alcohol (PA) is used to treat gastrointestinal dysfunction. The purpose of this study was to ascertain the function of PA in the regulated process of oxidative stress in rat intestinal epithelial cells (IEC-6). Materials and methods Oxidative stress was stimulated by exposing IEC-6 cells to heat shock (42 °C for 3 h). IEC-6 cells in treatment groups were pretreated with various concentrations of PA (10, 40, and 80 ng/mL) for 3 h before heat shock. Results Heat shock caused damage to the morphology of IEC-6 cells, and increased reactive oxygen species (ROS) level and malondialdehyde (MDA) content. Moreover, mRNA and protein expression by target genes related to oxidative stress in heat shock were also altered. Specifically, the mRNA expression by HSP70, HSP90, GSH-px, NRF2 nd HO-1were all increased, and Nrf2 and Keap1 protein expression were increased after heat shock. However, pretreatment with PA weakened the level of damage to the cellular morphology, and decreased the MDA content caused by heat shock, indicating PA had cytoprotective activities. Pretreatment with PA at high dose significantly increased generation of intracellular ROS. Compared with the heat shock group alone, PA pretreatment significantly decreased the mRNA expression by HSP70, HSP90, SOD, CAT, GSH-px, KEAP1 and HO-1. Furthermore, the high dose of PA significantly increased Nrf2 protein expression, while both the intermediate and high dose of PA significantly increased HO-1 protein expression. Conclusion Heat-shock-induced oxidative stress in IEC-6 cells, and PA could alleviate the Nrf2-Keap1 cellular oxidative stress responses.

  4. Optimal Selective Harmonic Mitigation Technique on Variable DC Link Cascaded H-Bridge Converter to Meet Power Quality Standards

    DEFF Research Database (Denmark)

    Najjar, Mohammad; Moeini, Amirhossein; Dowlatabadi, Mohammadkazem Bakhshizadeh

    2016-01-01

    In this paper, the power quality standards such as IEC 61000-3-6, IEC 61000-2-12, EN 50160, and CIGRE WG 36-05 are fulfilled for single- and three-phase medium voltage applications by using Selective Harmonic Mitigation-PWM (SHM-PWM) in a Cascaded H-Bridge (CHB) converter. Furthermore, the ER G5/...

  5. 11 CFR 7.27 - Hearing examiner designation and qualifications.

    Science.gov (United States)

    2010-01-01

    ... complaint. (2) The examiner shall be an attorney at the Assistant General Counsel level or higher. ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Hearing examiner designation and qualifications. 7.27 Section 7.27 Federal Elections FEDERAL ELECTION COMMISSION STANDARDS OF CONDUCT Post Employment...

  6. Importance of international standards on hydrogen technologies

    International Nuclear Information System (INIS)

    Bose, T.K.; Gingras, S.

    2001-01-01

    This presentation provided some basic information regarding standards and the International Organization for Standardization (ISO). It also explained the importance of standardization activities, particularly ISO/TC 197 which applies to hydrogen technologies. Standards are established by consensus. They define the minimum requirements that will ensure that products and services are reliable and effective. Standards contribute to the elimination of technical barriers to trade (TBT). The harmonization of standards around the world is desirable in a free trade environment. The influence of the TBT on international standardization was discussed with particular reference to the objectives of ISO/TC 197 hydrogen technologies. One of the priorities for ISO/TC 197 is a hydrogen fuel infrastructure which includes refuelling stations, fuelling connectors, and storage technologies for gaseous and liquid hydrogen. Other priorities include an agreement between the International Electrotechnical Commission (IEC) and the ISO, in particular the IEC/TC 105 and ISO/TC 197 for the development of fuel cell standards. The international standards that have been published thus far include ISO 13984:1999 for liquid hydrogen, land vehicle fuelling system interface, and ISO 14687:1999 for hydrogen fuel product specification. Standards are currently under development for: liquid hydrogen; airport hydrogen fuelling facilities; gaseous hydrogen blends; basic considerations for the safety of hydrogen systems; gaseous hydrogen and hydrogen blends; and gaseous hydrogen for land vehicle filling connectors. It was concluded that the widespread use of hydrogen is dependent on international standardization

  7. Standard practice for qualification and acceptance of boron based metallic neutron absorbers for nuclear criticality control for dry cask storage systems and transportation packaging

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice provides procedures for qualification and acceptance of neutron absorber materials used to provide criticality control by absorbing thermal neutrons in systems designed for nuclear fuel storage, transportation, or both. 1.2 This practice is limited to neutron absorber materials consisting of metal alloys, metal matrix composites (MMCs), and cermets, clad or unclad, containing the neutron absorber boron-10 (10B). 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Analisis Sistem Manajemen Keamanan Informasi Menggunakan ISO/IEC 27001 : 2013 Serta Rekomendasi Model Sistem Menggunakan Data Flow Diagram pada Direktorat Sistem Informasi Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Yuni Cintia Yuze

    2016-11-01

    Full Text Available The importance of information and the possible risk of disruption, therefore the universities need to designed and implemented of the information security.  One of the standards that can be used to analyze the level of information security in the organization is ISO/IEC 27001 : 2013 and this standard has been prepared to provide requirements for establishing, implementing, maintaining and continually improving an information security management system. The objective of this research is to measure the level of information security based on standard ISO/IEC 27001: 2013 and modeling systems for information security management. This research uses descriptive qualitative approach, data collection and validation techniques with tringulasi (interview, observation and documentation. Data was analyzed using gap analysis and to measure the level of maturity this research uses SSE-CMM (Systems Security Engineering Capability Maturity Model. Based on the research results, Maturity level clause Information Security Policy reaches level 1 (Performed-Informally, clause Asset Management reaches level 3 (Well-Defined, clause Access Control reaches level 3 (Well-Defined, clause Physical and Environmental Security reaches level 3 (Well-Defined, clause Operational Security reaches level 3 (Well-Defined, Communication Security clause reaches the level 2 (Planned and Tracked. Based on the results of maturity level discovery of some weakness in asset management in implementing the policy. Therefore, the modeling system using the flow map and CD / DFD focused on Asset Management System.

  9. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    Science.gov (United States)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  10. New quantitative safety standards: different techniques, different results?

    International Nuclear Information System (INIS)

    Rouvroye, J.L.; Brombacher, A.C.

    1999-01-01

    Safety Instrumented Systems (SIS) are used in the process industry to perform safety functions. Many factors can influence the safety of a SIS like system layout, diagnostics, testing and repair. In standards like the German DIN no quantitative analysis is demanded (DIN V 19250 Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, Berlin, 1994; DIN/VDE 0801 Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Berlin, 1990). The analysis according to these standards is based on expert opinion and qualitative analysis techniques. New standards like the IEC 61508 (IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems, IEC, Geneve, 1997) and the ISA-S84.01 (ISA-S84.01.1996 Application of Safety Instrumented Systems for the Process Industries, Instrument Society of America, Research Triangle Park, 1996) require quantitative risk analysis but do not prescribe how to perform the analysis. Earlier publications of the authors (Rouvroye et al., Uncertainty in safety, new techniques for the assessment and optimisation of safety in process industry, D W. Pyatt (ed), SERA-Vol. 4, Safety engineering and risk analysis, ASME, New York 1995; Rouvroye et al., A comparison study of qualitative and quantitative analysis techniques for the assessment of safety in industry, P.C. Cacciabue, I.A. Papazoglou (eds), Proceedings PSAM III conference, Crete, Greece, June 1996) have shown that different analysis techniques cover different aspects of system behaviour. This paper shows by means of a case study, that different (quantitative) analysis techniques may lead to different results. The consequence is that the application of the standards to practical systems will not always lead to unambiguous results. The authors therefore propose a technique to overcome this major disadvantage

  11. Photovoltaic Module Qualification Plus Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wohlgemuth, John [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kempe, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bosco, Nick [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hacke, Peter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jordan, Dirk [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Silverman, Timothy J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Phillips, Nancy [3M Company, Maplewood, MN (United States); Earnest, Thomas [DuPont, Wilmington, DE (United States); Romero, Ralph [Black & Veatch, Overland Park, KS (United States)

    2013-12-01

    This report summarizes a set of test methods that are in the midst of being incorporated into IEC 61215 for certification of a module design or other tests that go beyond certification to establish bankability.

  12. Technical basis for environmental qualification of computer-based safety systems in nuclear power plants

    International Nuclear Information System (INIS)

    Korsah, K.; Wood, R.T.; Tanaka, T.J.; Antonescu, C.E.

    1997-01-01

    This paper summarizes the results of research sponsored by the US Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. This research was conducted by the Oak Ridge National Laboratory (ORNL) and Sandia National Laboratories (SNL). ORNL investigated potential failure modes and vulnerabilities of microprocessor-based technologies to environmental stressors, including electromagnetic/radio-frequency interference, temperature, humidity, and smoke exposure. An experimental digital safety channel (EDSC) was constructed for the tests. SNL performed smoke exposure tests on digital components and circuit boards to determine failure mechanisms and the effect of different packaging techniques on smoke susceptibility. These studies are expected to provide recommendations for environmental qualification of digital safety systems by addressing the following: (1) adequacy of the present preferred test methods for qualification of digital I and C systems; (2) preferred standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging in qualification testing for equipment that is to be located in mild environments; and (5) determination of an appropriate approach to address smoke in a qualification program

  13. Lessons learned in the environmental qualification of class IE equipment at Tennessee Valley Authority

    International Nuclear Information System (INIS)

    Bell, R.N.; Akos, T.

    1985-01-01

    Tennessee Valley Authority has been engaged in an extensive program for the environmental qualification of Class 1E components. This program has been conducted in accordance with the requirements set forth in various industry standards and federal regulations, including IEEE 323-1971, IEEE 323-1974, Nuclear Regulatory Commission (NRC) IE Bulletin 7901B, NRC NUREG-0588, and the Code of Federal Regulations 10CFR50.49. Valuable lessons have been learned as a result of this program, particularly in the area of environmental qualification testing. This paper describes some unique experiences in the qualification testing of main steam isolation valve control manifold assemblies, control relays, and motor control centers

  14. Chapter 9. Personnel qualification and training

    International Nuclear Information System (INIS)

    2001-01-01

    the direct supervision of the trainer within 4 to 10 weeks after the successful completion of both written and oral of examination. Last year the committee held thirteen sessions for oral theoretical examination. The number of licenses issued in 2000 and the total number of valid licenses is given in table. The standard of professional skills of the staff at nuclear installations is a very important factor for assuring and maintaining a high level of nuclear safety of nuclear installations. Conclusions from inspections and tests as well as results from operation and start up of nuclear units confirm that in this area a high standard of operational safety is being achieved on a permanent basis. Increasing the qualification of UJD staff was done in a form of training and courses scheduled in the plan of training for UJD staff for 2000. These training, composed of specialised qualification study, functional study, as well as study aimed at maintaining qualification. Training courses organised by the Government Office of Slovakia and the IAEA were also of a significant benefit and UJD staff participated on foreign training courses, seminars and conferences, focusing on maintaining and improvement of professional skills. In January 2000 the agreement on co-operation with the Faculty of Natural Science of Comenius University in Bratislava and UJD on INIS system performance (INIS Slovak National Center) was signed

  15. Standardization in smart grids. Introduction to IT-related methodologies, architectures and standards

    Energy Technology Data Exchange (ETDEWEB)

    Uslar, Mathias; Specht, Michael; Daenekas, Christian; Trefke, Joern; Rohjans, Sebastian; Gonzalez, Jose M.; Rosinger, Christine; Bleiker, Robert [OFFIS - Institut fuer Informatik, Oldenburg (Germany)

    2013-03-01

    Introduction to Standardization for Smart Grids. Presents a tutorial and best practice of Smart Grid Prototype Projects. Written by leading experts in the field. Besides the regulatory and market aspects, the technical level dealing with the knowledge from multiple disciplines and the aspects of technical system integration to achieve interoperability and integration has been a strong focus in the Smart Grid. This topic is typically covered by the means of using (technical) standards for processes, data models, functions and communication links. Standardization is a key issue for Smart Grids due to the involvement of many different sectors along the value chain from the generation to the appliances. The scope of Smart Grid is broad, therefore, the standards landscape is unfortunately very large and complex. This is why the three European Standards Organizations ETSI, CEN and CENELEC created a so called Joint Working Group (JWG). This was the first harmonized effort in Europe to bring together the needed disciplines and experts delivering the final report in May 2011. After this approach proved useful, the Commission used the Mandate M/490: Standardization Mandate to European Standardization Organizations (ESOs) to support European Smart Grid deployment. The focal point addressing the ESO's response to M/490 will be the CEN, CENELEC and ETSI Smart Grids Coordination Group (SG-CG). Based on this mandate, meaningful standardization of architectures, use cases, communication technologies, data models and security standards takes place in the four existing working groups. This book provides an overview on the various building blocks and standards identified as the most prominent ones by the JWG report as well as by the first set of standards group - IEC 61850 and CIM, IEC PAS 62559 for documenting Smart Grid use cases, security requirements from the SGIS groups and an introduction on how to apply the Smart Grid Architecture Model SGAM for utilities. In addition

  16. Implementation of draft IEC Generic Model of Type 1 Wind Turbine Generator in PowerFactory and Simulink

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Sørensen, Poul Ejnar

    2013-01-01

    This paper presents the implementation work of IEC generic model of Type 1 wind turbine generator (WTG) in two commercial simulation tools: DIgSILENT PowerFactory (PF) and Matlab Simulink. The model topology, details of the composite blocks and implementation procedure in PF and Simulink environm......This paper presents the implementation work of IEC generic model of Type 1 wind turbine generator (WTG) in two commercial simulation tools: DIgSILENT PowerFactory (PF) and Matlab Simulink. The model topology, details of the composite blocks and implementation procedure in PF and Simulink...

  17. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Korsah, K.; Wood, R.T.; Hassan, M.; Tanaka, T.J.

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

  18. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Wood, R.T. [Oak Ridge National Lab., TN (United States); Hassan, M. [Brookhaven National Lab., Upton, NY (United States); Tanaka, T.J. [Sandia National Labs., Albuquerque, NM (United States)

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants.

  19. QUALIFICATIONS FRAMEWORKS LEADING TO REFORMS IN EAST EUROPEAN EDUCATION

    Directory of Open Access Journals (Sweden)

    Arjen Vos

    2014-01-01

    Full Text Available The paper examines the evolution of qualifications frameworks across Europe. Five years ago, it was not clear if the discussions on national qualification frameworks (NQF in Eastern Europe would lead to the new standards and qualifications development, or initiate the reforms in education and training. Now, there is evidence of more countries using the NQFs to promote a dialogue between the public and private sectors on the expected outcomes of educational process. In some countries, the private sector has even taken the lead in the NQF discussions, being increasingly involved in their implementation. This is a fundamentally new paradigm in education policies and a cornerstone of the demand driven education and training. Each country is following its own patterns while moving to the comparable results. However, this is just the initial stage of NQF implementation. The author regards learning by doing and the local expertise expansion as the key challenges of the coming years. Although the reforms take time, they increasingly tend to become a shared public and private responsibility.

  20. Qualification of flat welding of nuclear fuel bars

    International Nuclear Information System (INIS)

    Romero C, J.; Rivera M, H.

    2001-01-01

    The qualification of flat welding consists in the process (procedures (11), instructions (5), specifications (4) and programs (3)) and equipment (systems (4), equipment (6)) with the Personal Qualification (operators and supervisors) that was done in simultaneous form and supported with test and training programs with its respective technical reports, liberated by the Quality Assurance Office of ININ. Moreover, specific procedures of process and personal qualification are realized with the respective supervision by Quality Assurance Office. For the process, 20 welding were realized as follow: 5 welding with maximum contributing of heat, 10 welding with nominal contributing of heat, 5 welding with minimum contributing of heat. The heat contributing for the qualification was done maximum, of increasing the welding current, diminishing the helium flux and the revolutions per minute of the bar, at the moment of welding, with respect to nominal values. In the minimum contributing of heat it is diminished the welding current, increasing the helium flux and the revolutions per minute of the bar with respect to nominal values. With the qualification it has been finished the development of flat welding with results which define an own method of ININ. It was implemented a pneumatic system, for the elimination of micron cracks. It was required a control of turn velocity of the bar of hundredth of revolution. Moreover the main welding parameters each 40 μs are acquired. Also it was automated completely the process to avoid possible human mistakes. The standard deviations of the values of the realized inspections in the quality, are lower. Process, equipment and personnel with their respective Quality reports and registries are qualified, as well as the Quality certificates of two operators and one supervisor. (Author)

  1. IEEE Std 323-1983: IEEE standard for qualifying Class 1E equipment for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the basic requirements for qualifying Class 1E equipment with interfaces that are to be used in nuclear power generating stations. The requirements presented include the principles, procedures, and methods of qualification. These qualification requirements, when met, will confirm the adequacy of the equipment design under normal, abnormal, design basis event, post design basis event, and in-service test conditions for the performance of safety function(s). The purpose of this standard is to identify requirements for the qualification of Class 1E equipment, including those interfaces whose failure could adversely affect the performance of Class 1E equipment and systems. The methods described shall be used for qualifying equipment, extending qualification, and updating qualification if the equipment is modified. Other issued IEEE standards which present qualification methods for specific equipment or components, or both, and those that deal with parts of the qualification program, may be used to supplement this standard, as applicable

  2. 5 CFR 302.403 - Qualifications for promotion.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Qualifications for promotion. 302.403... EMPLOYMENT IN THE EXCEPTED SERVICE Selection and Appointment; Reappointment; and Qualifications for Promotion § 302.403 Qualifications for promotion. In determining qualifications for promotion with respect to an...

  3. Air kerma standardization for diagnostic radiology, and requirements proposal for calibration laboratories

    International Nuclear Information System (INIS)

    Ramos, Manoel Mattos Oliveira

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. A metrology network was created, but it is not yet accredited by the accreditation organism of the country, INMETRO. The objective of this work was to implement the standardization of the air kerma for the un attenuated qualities (RQR) of IEC 61267, and to develop a requirement proposal for instruments calibration laboratories. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. A laboratory requirement proposal was finalized and it shall be submitted to INMETRO to be used as auxiliary normative document in laboratory accreditation. (author)

  4. Protective effects of essential oil of Citrus limon against aspirin-induced toxicity in IEC-6 cells.

    Science.gov (United States)

    Bouzenna, Hafsia; Hfaiedh, Najla; Giroux-Metges, Marie-Agnès; Elfeki, Abdelfattah; Talarmin, Hélène

    2017-05-01

    Aspirin, one of the widely used nonsteroidal anti-inflammatory drugs, is the most highly consumed pharmaceutical product in the world. However, it has several side effects in cells. This study was designed to investigate the antioxidative activity and cytoprotective effects of essential oil of Citrus limon (EOC) extracted from leaves against aspirin-induced damages in the rat small intestine epithelial cells (IEC-6). Biochemical indicators were used to assess cytotoxicity and oxidative damages caused by aspirin treatment on IEC-6. Our results showed that the chemical characterization of EOC identified 25 compounds representing 98.19% of the total oil. The major compounds from this oil were z-citral (53.21%), neryl acetate (13.06%), geranyl acetate (10.33%), and limonene (4.23%). Aspirin induced a decrease in cell viability as well as an increase in superoxide dismutase (SOD) and catalase (CAT) activities. Contrariwise, the co-exposure of cells to aspirin and EOC alleviated every above syndrome by an increase in cell survival and decrease in SOD and CAT activities. In conclusion, the essential oil of C. limon has a potent cytoprotective effect against aspirin-induced toxicity in IEC-6 cells.

  5. The french safety approach regarding equipment qualification

    International Nuclear Information System (INIS)

    Jalouneix, J.; Deletre, G.; Henry, J.Y.; Rousseau, L.

    1989-10-01

    The qualification of the equipment, used in France on nuclear reactors and reactor components, is discussed. The approach on safety involves the qualification of mechanical and electrical components, under operating and under seismic conditions. The principles of the qualification program and the list of the equipment concerned, are given. The conditions in which qualification tests are performed and the methods applied, are summarized. The actions for preserving the qualification procedures, are considered

  6. Special aspects of hemo-dynamic and reaction of erythrocytes in blood to standard physical load of different qualification female volleyball players

    Directory of Open Access Journals (Sweden)

    S. L. Popel’

    2017-10-01

    Full Text Available Purpose: to study the aspects of organism’s cardio-hemo-dynamic and blood erythrocytes reaction of female volleyball players to standard physical load. Material: with functional methods we studied cardio-hemo-dynamic and with the help of scanning electronic microscopy - erythrocytes’ structure in 18 female volleyball players of different qualification (age - 22.0±0.60 years. Results: it was found that maximal physical load causes substantial changes in cardio-hemo-dynamic, which depend on female volleyball players’ qualification. These changes have intrinsic to them type of blood circulation system reacting, which is manifested in the following: appropriate changes of some indicators; natural changes of periphery blood erythrocytes. In the article possible mechanisms of realization of female volleyball players’ organism’s typological features, depending on blood circulation type and erythrocytes’ conformation, are discussed. Conclusions: In relaxed state all female volleyball players have non-uniform cardio-hemo-dynamic of blood circulation. With hyper-dynamic blood circulation type, higher indicators of strike and minute blood volume were observed. With hypo-kinetic blood circulation type the opposite picture was observed: indicators of strike and minute blood volume, heart index, load on cardio-vascular system in different periods of day were low.

  7. Automation of an energy-autarkic manufacturing plant following IEC 61499; Automatisierung einer energieautarken Fertigungsanlage nach IEC 61499

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, Christian; Hirsch, Martin; Hanisch, Hans-Michael [Halle-Wittenberg Univ., Halle (Saale) (Germany). Lehrstuhl Automatisierungstechnik

    2009-07-01

    The requirements for future manufacturing plants are, beyond others, seamless reconfiguration, autonomy as far as possible as well as easy employment and maintenance for the end user. Within the EnAS project (Energy-Autarkic Actuators and Sensors), the group of the Automation Technology Lab in Halle has challenged the fulfillment of those requirements. Therefore, IEC 61499 compliant distributed controllers have been developed for the demonstrator-plant under particular consideration of reconfigurability. These controllers have been integrated into the process sequences of the demonstrator and afterwards several reconfiguration scenarios have been designed. The building of a Human-Machine-Interface for visualization and reconfiguration of the plant was an essential issue as well. The result is a highly flexible, easily reconfigurable system, which can be regarded as a prototype for automated manufacturing plants of a new generation. (orig.)

  8. Secondary standard dosimetry laboratory at INFLPR

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F.; Minea, R.; Scarisoreanu, A.; Badita, E.; Sima, E.; Dumitrascu, M.; Stancu, E.; Vancea, C., E-mail: scarlat.f@gmail.com [National Institute for Laser, Plasma and Radiation Physics - INFLPR, Bucharest (Romania)

    2011-07-01

    National Institute for Laser, Plasma and Radiation Physics (INFLPR) has constructed a High Energy Secondary Standard Dosimetry Laboratory SSDL-STARDOOR - for performing dosimetric calibrations according to ISO IEC SR/EN 17025:2005 standards. This is outfitted with UNIDOS Secondary Standard Dosimeter from PTW (Freiburg Physikalisch-Technische Werksttaten) calibrated at the PTB-Braunschweig (German Federal Institute of Physics and Metrology). A radiation beam of the quality of Q used by our laboratory as calibration source are provided by INFLPR 7 MeV electron beam linear accelerator mounted in our facility. (author)

  9. Model-driven design using IEC 61499 a synchronous approach for embedded and automation systems

    CERN Document Server

    Yoong, Li Hsien; Bhatti, Zeeshan E; Kuo, Matthew M Y

    2015-01-01

    This book describes a novel approach for the design of embedded systems and industrial automation systems, using a unified model-driven approach that is applicable in both domains.  The authors illustrate their methodology, using the IEC 61499 standard as the main vehicle for specification, verification, static timing analysis and automated code synthesis.  The well-known synchronous approach is used as the main vehicle for defining an unambiguous semantics that ensures determinism and deadlock freedom. The proposed approach also ensures very efficient implementations either on small-scale embedded devices or on industry-scale programmable automation controllers (PACs). It can be used for both centralized and distributed implementations. Significantly, the proposed approach can be used without the need for any run-time support. This approach, for the first time, blurs the gap between embedded systems and automation systems and can be applied in wide-ranging applications in automotive, robotics, and industri...

  10. Meeting the latest qualification requirements for Class 1E protection system equipment: a practical approach

    International Nuclear Information System (INIS)

    Daigle, R.P.; Breen, R.J.

    1977-01-01

    The requirements for qualifying Class 1E equipment for Nuclear Power Generating Stations were significantly revised in 1974 and 1975. These new requirements reflect the desire of the industry to provide improved methods of determining the qualification of this vital equipment. The revised standards do, in fact, meet these industry goals in a generally acceptable manner. The Nuclear Regulatory Commission is presently requiring utilities to comply with these revised standards and regulatory guides in order to obtain the necessary permits. Manufacturers are developing and implementing programs to comply with the new requirements. One of the more difficult new requirements of qualification is aging to achieve advanced life condition. The objectives and methods described for aging are difficult for much of the equipment within the Protection System. The use of thermal and vibrational techniques to simulate aging is valid for some components (i.e., capacitors, transistors, cable and/or motor insulation) but may be neither valid nor practical for many items (e.g., complete instrument systems, etc.). A seemingly obvious approach, although rarely followed, in regarding new or revised standards is to refrain from making any type of commitment until the standards are thoroughly understood. Often too hasty a decision is made by a utility (concerned about licensing) or a manufacturer (concerned about being competitive) to commit to new requirements. Consequently, the broad range of interpretations that usually develops for a given set of requirements may result in difficult relations between organizations. This paper deals with solutions for qualification in a practical sense, with emphasis on the aging issue and does not elaborate on seismic qualification

  11. 5 CFR 319.302 - Individual qualifications.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Individual qualifications. 319.302... Individual qualifications. Agency heads are delegated authority to approve the qualifications of individuals appointed to SL and ST positions. The agency head must determine that the individual meets the...

  12. Análisis de la norma ISO/IEC 27001 : Diseño de implementación en la red de una empresa.

    OpenAIRE

    Sandoval Vargas, César Andrés

    2014-01-01

    Durante el proceso de esta investigación se aborda el tema relacionado con la seguridad informática, haciendo énfasis en el análisis de la norma ISO/IEC (International Organization for Standardization / International Electrotechnical Commission) 27001 y su puesta en práctica en una empresa o institución. El trabajo se encuentra dividido en tres capítulos. En el primero se efectúa un estudio de la seguridad informática.- Durante el segundo capítulo se lleva a cabo una caracterización general ...

  13. A study on the implementation of an integrated Environmental Qualification Management System(EQMS) for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Bhang, Keug Jin; Jeong, Sun Chul; Kang, Pil Sun [KHNP CRI, Daejeon (Korea, Republic of)

    2012-10-15

    Environmental Qualification Management System(EQMS) for Nuclear Power Plant is a web based program for preventing degradation and managing original functions of environmental qualification equipment during nuclear power plant life cycle by inspecting and improving status of them periodically. But cognitive issues have stayed in the construction phase of EQMS: almost EQ equipment are not registered in DREAMS because the approach is not based on a standard data structure. In this study, we are to obtain the requirements of integrated EQMS by considering a standard and surveying the problems of current EQMS.

  14. A study on the implementation of an integrated Environmental Qualification Management System(EQMS) for nuclear power plant

    International Nuclear Information System (INIS)

    Bhang, Keug Jin; Jeong, Sun Chul; Kang, Pil Sun

    2012-01-01

    Environmental Qualification Management System(EQMS) for Nuclear Power Plant is a web based program for preventing degradation and managing original functions of environmental qualification equipment during nuclear power plant life cycle by inspecting and improving status of them periodically. But cognitive issues have stayed in the construction phase of EQMS: almost EQ equipment are not registered in DREAMS because the approach is not based on a standard data structure. In this study, we are to obtain the requirements of integrated EQMS by considering a standard and surveying the problems of current EQMS

  15. Analysis of Norm IEC 61850 in the transmission of data via communications network of substations

    Energy Technology Data Exchange (ETDEWEB)

    Renda, T.; Botura Junior, G. [Universidade Estadual Paulista (UNESP), Sorocaba, SP (Brazil); Mesquita, L.; Rizol, P.M.S.R. [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil)

    2009-07-01

    The tendency of using a protocol allows electrical substations to become 'intelligent', that is, capable of communicating in a much more efficient manner. This greatly reduces the number of connections, and as a consequence optimizes the speed between messages. The Norm IEC 61850-9-2 came to minimize the use of cables for the interconnections of various equipment involved in safety procedures of a substation. The present paper, has the objective of identifying a way of integrating the Norm IEC-61850 with the transmission of data via 'Generic Object Oriented Substation Event' (GOOSE) and of substituting the direct connection of binary I/O's of the Intelligent Electronic Devices also known as IED's. (author)

  16. Metodología para la implementación de un Sistema de Gestión de Seguridad de la Información basado en la familia de normas ISO/IEC 27000

    OpenAIRE

    Valencia-Duque, Francisco Javier; Orozco-Alzate, Mauricio

    2017-01-01

    Se propone una metodología de implementación de un Sistema de Gestión de Seguridad de la Información (SGSI) basado en la familia de normas de la ISO/IEC 27000, con énfasis en la interrelación de cuatro normas fundamentales a través de las cuales se desarrollan las actividades requeridas para cumplir con lo establecido en la ISO/IEC 27001, los controles de seguridad presentados en la ISO/IEC 27002, el esquema de riesgos de la ISO/IEC 27005 y los pasos recomendados en la ISO/IEC 27003. Se gener...

  17. VHDL basics applied design by SIPAC qualification system

    International Nuclear Information System (INIS)

    Park, In Ha; Mun, Da Cheol; Lee, Gwang Yeob

    2005-12-01

    This book has six chapters, which are about Flowrian of SIPAC qualification system including internet CAD system and remote server service, logic circuit on design and qualification of device such as gate circuit, multiplex and decoder, order logic circuit with D type flip-flop design and qualification and Rom and RAM's design and qualification, finite state machine such as odd checker, sequence detector, test clock generator and traffic light controller, design and qualification about data path, design of application circuit. It has two appendixes on install and the way to use SIPAC qualification system and remote service for SIPAC qualification system.

  18. Chapter 9. Personnel qualification and training

    International Nuclear Information System (INIS)

    2000-01-01

    In 1999 the Nuclear Regulatory Authority of the Slovak Republic (UJD) focused on the overall training system and on developing programmes for individual categories for NPP V-1 Bohunice, NPP V-2 Bohunice, NPP Mochovce and SE-VYZ. The fundamental theoretical and periodical training for both Bohunice and Mochovce NPPs personnel, simulator training for NPP Bohunice, and periodical simulator training for Bohunice personnel is carried out by the VUJE Training center in Trnava, whereas the simulator training and periodical training for NPP Mochovce is carried at Mochovce plant. Based on a successful passing of examination before the examining committee, UJD issues, a certificate on special professional skills of selected staff of nuclear installations for specific activity for the given type of nuclear installation and for the following positions: (a)Shift manager for scientific start up with the right of manipulation; (b) Shift supervisor; (c) Unit supervisor; (d) Primary circuit operator; (e) Secondary circuit operator; (f) Reactor physicist; (g) Shift manager for scientific start up without the right of manipulation. Examination of selected personnel is described. Last year the examining committee held twelve session for oral theoretical examination. The number of licenses issued in 1999 and the total number of valid licenses is given.Conclusions from inspections carried out by UJD and inspections and tests carried out by the NPP operators in 1999, as well as results from operation and start up of nuclear units confirm that the standard of professional skills of the staff at nuclear installations a high standard of operational safety is being achieved on a permanent basis. Increasing the qualification of UJD staff was done in a form of training and courses scheduled in the plan of training for the staff for 1999. These training, composed of specialized qualification study, functional study, as well as study aimed at maintaining qualification. Training courses organized

  19. Software qualification in safety applications

    International Nuclear Information System (INIS)

    Lawrence, J.D.

    2000-01-01

    The developers of safety-critical instrumentation and control systems must qualify the design of the components used, including the software in the embedded computer systems, in order to ensure that the component can be trusted to perform its safety function under the full range of operating conditions. There are well known ways to qualify analog systems using the facts that: (1) they are built from standard modules with known properties; (2) design documents are available and described in a well understood language; (3) the performance of the component is constrained by physics; and (4) physics models exist to predict the performance. These properties are not generally available for qualifying software, and one must fall back on extensive testing and qualification of the design process. Neither of these is completely satisfactory. The research reported here is exploring an alternative approach that is intended to permit qualification for an important subset of instrumentation software. The research goal is to determine if a combination of static analysis and limited testing can be used to qualify a class of simple, but practical, computer-based instrumentation components for safety application. These components are of roughly the complexity of a motion detector alarm controller. This goal is accomplished by identifying design constraints that enable meaningful analysis and testing. Once such design constraints are identified, digital systems can be designed to allow for analysis and testing, or existing systems may be tested for conformance to the design constraints as a first step in a qualification process. This will considerably reduce the cost and monetary risk involved in qualifying commercial components for safety-critical service

  20. International Standards Development for Marine and Hydrokinetic Renewable Energy - Final Report on Technical Status

    Energy Technology Data Exchange (ETDEWEB)

    Rondorf, Neil E.; Busch, Jason; Kimball, Richard

    2011-10-29

    This report summarizes the progress toward development of International Standards for Marine and Hydrokinetic Renewable Energy, as funded by the U.S. Department of Energy (DOE) under the International Electrotechnical Commission (IEC) Technical Committee 114. The project has three main objectives: 1. Provide funding to support participation of key U.S. industry technical experts in 6 (originally 4) international working groups and/or project teams (the primary standards-making committees) and to attend technical meetings to ensure greater U.S. involvement in the development of these standards. 2. Provide a report to DOE and industry stakeholders summarizing the IEC standards development process for marine and hydrokinetic renewable energy, new international standards and their justifications, and provide standards guidance to industry members. 3. Provide a semi-annual (web-based) newsletter to the marine renewable energy community. The newsletter will educate industry members and stakeholders about the processes, progress, and needs of the US efforts to support the international standards development effort. The newsletter is available at www.TC114.us

  1. Risikomanagement für medizinische Netzwerke in der Intensiv- und Notfallmedizin. Gemeinsames Positionspapier zur Norm IEC 80001-1 [Risk management for medical networks in intensive care and emergency medicine – a joint position paper on IEC 80001-1

    Directory of Open Access Journals (Sweden)

    Imhoff, Michael

    2013-02-01

    Full Text Available [english] IEC 80001-1 is an international standard and offers recommendations for a risk management process for medical information technology networks (MITs. MITs are defined as IT networks incorporating at least one medical device. The goal is to build and maintain reliable and secure MITs for hospitals of all kids. To achieve it, the standard suggests applying risk management and defines the roles involved as well as their responsibilities. A central role is the medical IT-network risk manager, assigned by the top management of organizations. He communicates with and mediates between clinical, medical device and IT divisions and compiles risk relevant facts usually distributed among them. All identified risks are analyzed, evaluated and documented in the risk management file along with counter measures and a final assessment of acceptability.We acknowledge that implementing the suggested process will create an overhead cost in documentation and – partly by extension – in personnel. However we believe that the investment at the start of projects is worthwhile, because it helps to prevent or solve problems in later stages. Especially consecutive projects can profit from the investment, reducing required effort and costs. Furthermore, a reliable and secure MIT forms the basis for frictionless routine operations and innovations for connected medical devices. Hence the investment is justified. Applying risk management to the whole cooperation all at once is unrealistic. Focusing on parts of the network, which are crucial to a new project is more recommendable. With a smaller scope, risk management remains feasible and can later be expanded to other parts of the network.IEC 80001-1 demands communication among involved employees from different specialties and divisions. This offers a chance for cooperation to find better decisions and solutions regarding an organization’s medical IT network.[german] Die IEC 80001-1 ist eine Norm, die

  2. Occupational scope and qualification of environment experts in public administration. Final report. Berufsfeld- und Qualifikationsanalyse fuer Umweltfachleute in der Oeffentlichen Verwaltung. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Brater, M; Hemmer, C; Maurus, A; Munz, C; Schluchter,

    1991-12-01

    The publication presents the three parts of the original report in one volume. The parts refewing to occupational qualifications consistently differentiate between occupation all specific qualification standards and those of a non-specific nature. Environmental protection is defined to be based on pollution control as a matter of engineering, pollution abatement as a matter of planning and regulatory activities, and the integrated version of the two strategies. Experts in public administration specialising in environmental protection are to be trained as experts in the following sub-areas environmental planning (innovation and strategy planning); design planning (engineering aspects); environmental law (impact statements, expert opinions, special knowledge of environmental media); enforcement of the law, licensing procedure, monitoring and supervision (efficiency evaluation); public relations (information, consultancy, education). The report presents job descriptions, qualification standards, occupational scopes and prospects for every type of qualification and education. (HSCH).

  3. Register of international standard NP on IT based wireless application in nuclear power plants

    International Nuclear Information System (INIS)

    Koo, I. S.; Hong, S. B.; Cho, I. W.; Choi, Y. S.; Lee, J. C.

    2011-04-01

    DC draft of standard technical report for wireless applications in NPP is developed, which is a Korean IT technologies. Wireless technologies are forwardwd to converging technologies nuclear and IT area. These technologies are supported to reduce vulnerability against cyber attacks and are forwarded to international standards which met with the nuclear environment requirements. DC draft of standard technical report is provided and circulated. Korean experts participate in Plenary meeting for IEC TC45/SC45A and intermediate meeting for IEC SC45A/WGA3 and 9. Korean expert takes the chair of wireless session at ANS winter conference. Visible light communication is experimented for feasibility study on reducing vulnerability against cyber attacks. VLC is capable of robust wireless communication against cyber attacks. This is suggested to describe a method for technical report. Issue DTR for wireless applications in NPP in 2012

  4. Qualification test of Class 1E equipment based on IEEE323 Std 2003

    International Nuclear Information System (INIS)

    Kim, J. S.; Jung, S. C.; Kim, T. R.

    2004-01-01

    IEEE Standard for Qualifying Class 1E Equipment has been updated to 2003 edition since the issue of IEEE Std 323-1971, 1974, 1983. NRC approved the IEEE Std 323-1974 as Qualification standard of Class 1E Equipment in domestic nuclear power plant. IEEE Std 323-2003 was issued in September of 2003 and utility is waiting the approval of NRC. IEEE Std 323-2003 suggest a new qualification technique which adopts the condition monitoring. Performance of two transient during DBA test is no longer recommended in IEEE Std 323-2003. IEEE323 Std 2003 included a chapter of ''extension of Qualified life'' to make available the life extension of components during plant life extension. For the efficient control of preserving EQ in domestic nuclear power plant, IEEE323 Std 2003 is strongly recommended

  5. Nuclear safety review for qualification of class 1E motor inside containment for nuclear power stations

    International Nuclear Information System (INIS)

    Li Shixin; Wu Qi; Zhang Yunbo; Wu Caixia

    2013-01-01

    In nuclear power plants with pressurized water reactors, the review for class 1E motor inside containment qualification process and documents is an important aspect of nuclear safety equipment review, and the reviewers should make evaluations for the qualification test results in terms of the compliance with standard and regulation, and the consistency with inside containment environment. Firstly, this paper introduces the qualification test of class 1E motor inside containment for nuclear power generating stations, such as aging test and design-basis-event test. Second, there is a discussion about typical problems of review. At last, comparison of IEEE334 with RCC-E is conducted and explored. (authors)

  6. Test-qualification experience with non-destructive material analysis system performed at Paks Nuclear Power Plant and its usage in non-nuclear fields

    International Nuclear Information System (INIS)

    Somogyi, Gy.; Szabo, D.

    2003-01-01

    The need for qualification of non-destructive material analysis has been recognised in controlling nuclear energy production process. This test-qualification has been performed as first of its kind after the task has been assigned by the National Nuclear Energy Agency. The input documents for the test were. Technical Specification, Analysis Technology, Technical Justification. Test-qualification has been performed with real form control bodies developed by the Rez Nuclear Research Institute, in which the planned defects has been produced by spark-chipping. The qualification procedure has been summarized in a Qualification Folder and given to the national agency to issue a qualification certificate. The procedure might be interesting mostly for companies delivering nuclear power plant assemblies. Similar needs are formulated in standards relative to the qualification of non-nuclear material testing methods (MSZ EN 17025 and EU). (Gy.M.)

  7. Present status of standards relating to radiation control and protection

    International Nuclear Information System (INIS)

    Minami, Kentaro

    1996-01-01

    Japanese and international standards related to radiation control and radiation protective management are presented focusing on the forming condition, significance, current situation, and their relationship. Japanese Industrial Standards (JIS) is quite useful in the field of atomic energy as well as other fields in terms of optimization and rationalization of the management. JIS includes JIS Z 4001 Atomic Energy Terminology which corresponds to internationl standards ISO 921 Nuclear Glossary, and JIS Z 4005 Medical Radiation Terminology, covering about 500 articles, which corresponds to IEC 788 Medical Radiology-Terminology. The first standards regarding radiation protection was established in X-ray Film Badge, which is included in the field of personal dosimeter, in 1956. Currently, 36 JIS has been established in the field of radiation management dosimeter and 3 are under arrangement. As for radiation protective supplies, 9 JIS has been established so far. Before proposal of JIS, investigation had been conducted to improve, simplify, and standardize the standards of radiation dosimetric technique, dosimeters, dosimetric procedures, and improvement. In this article, the results of material surface contamination monitoring and body surface monitoring conducted in Atomic Energy Safety Association and Radiation Dosimetry Associationare reported, and ISO and IEC are also treated. (S.Y.)

  8. Qualification of ISI for Bulgarian NPP: UK support

    International Nuclear Information System (INIS)

    Booler, R.

    2000-01-01

    UK Regulator (NII) Phare project provides an assistance to the Bulgarian Regulator in setting up the technical infrastructure for inspection qualification consistent with IAEA Guidelines and western European practice. The Strategy Document defines the methodology for inspection qualification and general roles and responsibilities of the involved organizations. The Qualification Inputs Document describes the information required for the Technical Specifications (component details, inspection aims and limitations). It applies the idea of qualification level - level 1(lowest) to level 3 (highest). The Qualification Procedure Document provides a guidance to the utility ('Kozloduy' NPP) on the preparation of Qualification Procedures (QP). The appendix provides a specific guidance on the performance of the all aspects of qualification at different levels and recommendations for technical justification. QB Method Working Document provides guidance for the Qualification Body. Facilities and Resources Document defines the facilities and resources required for the Qualification Body to perform the tasks described in the Method Working Document. High level QA Document defines the principles of quality control. Other issues and progress report are also presented

  9. Parametrics for Molecular Deuterium Concentrations in the Source Region of the UW-IEC Device Using an Ion Acoustic Wave Diagnostic

    Science.gov (United States)

    Boris, D. R.; Emmert, G. A.

    2007-11-01

    The ion source region of the UW-Inertial Electrostatic Confinement device is comprised of a filament assisted DC discharge plasma that exists between the wall of the IEC vacuum chamber and the grounded spherical steel grid that makes up the anode of the IEC device. A 0-dimensional rate equation calculation of the molecular deuterium ion species concentration has been applied utilizing varying primary electron energy, and neutral gas pressure. By propagating ion acoustic waves in the source region of the IEC device the concentrations of molecular deuterium ion species have been determined for these varying plasma conditions, and high D3^+ concentrations have been verified. This was done by utilizing the multi-species ion acoustic wave dispersion relation, which relates the phase speed of the multi-species ion acoustic wave, vph, to the sum in quadrature of the concentration weighted ion acoustic sound speeds of the individual ion species.

  10. Complementing network security to the ISO/IEC 27000 standard

    OpenAIRE

    Alila, Patrick

    2007-01-01

    I syfte att öppna upp nya affärsmöjligheter för informationssäkerhetsföretaget Secure State AB, har detta arbete bedrivits för att komplettera företagets nuvarande standard för informationssäkerhetsarbete med ytterligare nätverkssäkerhet. Krav på slutresultatet var att dokumentet eller standarden skulle kunna komplettera ISO 27000, samt vara kostnadseffektivt. Efter en undersökning av den nämnda standarden konstaterades att enbart ISO 27000 i sig inte är ett fullgott verktyg för nätverkssäker...

  11. Pilot study approach and qualification dossier components

    International Nuclear Information System (INIS)

    Ammirato, F.; Ashwin, P.

    2000-01-01

    The aim of the Pilot Project is to evaluate the IAEA Guidelines and methodology for the benefit of IAEA Member States trough a simulation of qualification activities. The Project is based on a real component and available data - NPP Kozloduy unit 5, weld 3. The initial phase is limited to the Qualification dossier. The Project relies on the input from the team members and Member States. Team organization and responsibilities are presented. The components of the Qualification Dossier (technical specification, inspection procedure and preliminary review, qualification procedure) and their current status are also presented. A comparison is done with their qualification programs. The characteristics of performance demonstrations are discussed. The results show that the teamwork has been successful and the IAEA methodology covers all situations. It is expected that the End Project will become 'Benchmark's' for future qualification activities

  12. Benefits of Digital Equipment Generic Qualification Activities

    International Nuclear Information System (INIS)

    Thomas, James E.; Steiman, Samuel C.

    2002-01-01

    As a result of nuclear power plant instrumentation and control obsolescence issues, there have been numerous activities during recent years relating to the qualification of digital equipment. Some of these activities have been 'generic' in nature in that the qualification was not limited to plant specific applications, but was intended to cover a broad base of potential applications of the digital equipment. These generic qualifications have been funded by equipment manufacturers and by utility groups and organizations. The generic activities sponsored by the Electric Power Research Institute (EPRI) have been pilot projects for an overall generic qualification approach. The primary benefit resulting from the generic qualification work to date is that a number of digital platforms and digital devices are now available for use in various nuclear safety-related applications. Many of the tests and evaluations necessary to support plant specific applications have been completed. The amount of data and documentation that each utility must develop on a case by case basis has been significantly reduced. There are also a number of additional benefits resulting from these industry efforts. The challenges and difficulties in qualifying digital equipment for safety-related applications are now more clearly understood. EPRI has published a lessons learned document (EPRI Report 1001452, Generic Qualification of Commercial Grade Digital Devices: Lessons Learned from Initial Pilots, which covers several different qualification areas, including device selection, project planning, vendor surveys and design reviews, and electromagnetic compatibility (EMC) qualification. Application of the experience and lessons learned from the EPRI pilot activities should help reduce the effort and cost required for future qualification work. Most generic qualification activities for commercial equipment have been conducted using the approach of EPRI TR-106439, Guideline on Evaluation and Acceptance

  13. 49 CFR 180.507 - Qualification of tank cars.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Qualification of tank cars. 180.507 Section 180... QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars § 180.507 Qualification of tank cars. (a) Each tank car marked as meeting a “DOT” specification or any other tank car used...

  14. CLASSIFICATION OF SPECIALTIES AND QUALIFICATIONS IN REPUBLIC OF BELARUS: TENDENCIES AND PROSPECTS

    Directory of Open Access Journals (Sweden)

    O. A. Oleks

    2016-01-01

    Full Text Available In the present publication short data on the system of specialties and qualifications functioning in Republic of Belarus, her features, scope of application are given. The purpose and problems of the revision of the National classifier of the Republic of Belarus «Specialties and qualifications», its orientation to reduce the gap between the content of education and content of activity of graduates of establishments of education are described. The main tendencies of change of the operating classification – on the basis of types of economic activity and international standard classification of education taking into account requirements of employers, minimization of economic expenses for education, including due to minimization of classification units, rapprochement of positions with educational systems of other states are revealed. Prospects of development of national system of specialties and qualifications are disclosed. Tendencies and prospects of the expected changes are shown on the examples of the certain specialties offered by BNTU (Belarusian National Technical University.

  15. Qualification testing and electrical measurement experience: A manufacturer's view

    Science.gov (United States)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-11-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  16. ENIQ: European Network for Inspection Qualification

    International Nuclear Information System (INIS)

    Champigny, F.; Crutzen, S.; Lemaitre, P.

    1995-01-01

    Many countries are currently considering their own approach to inspection qualification and are carefully assessing experience to date. ENIQ, which stands for European Network for Inspection Qualification, groups the major part of the utilities in Western Europe. The general objective of ENIQ is to coordinate and manage at European level expertise and resources for the assessment and qualification of NDE inspection techniques and procedures, primarily for nuclear components. Also non-nuclear heavy duty components will be considered. Within ENIQ there is a growing consensus of opinion on the general principles of a European approach towards inspection qualification. In this paper the main activities, organization and actual status of ENIQ will be discussed

  17. 14 CFR 121.453 - Flight engineer qualifications.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Flight engineer qualifications. 121.453... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Crewmember Qualifications § 121.453 Flight engineer qualifications. (a) No certificate holder may use any person nor may any person serve as a flight engineer on an...

  18. Qualification issues for advanced light-water reactor protection systems

    International Nuclear Information System (INIS)

    Korsah, K.; Clark, R.L.; Antonescu, C.

    1993-01-01

    The instrumentation and control (I ampersand C) systems in advanced reactors will make extensive use of digital controls, microprocessors, multiplexing, and fiber optic transmission. Elements of these advances in I ampersand C have been implemented on some current operating plants. However, the widespread use of the above technologies, as well as the use of artificial intelligence with minimum reliance on human operator control of reactors, highlights the need to develop standards for qualifying the I ampersand C used in the next generation of nuclear power plants. As a first step in this direction, the protection system I ampersand C for present-day plants was compared to that proposed for advanced light-water reactors (ALWRs). An evaluation template was developed by assembling a configuration of a safety channel instrument string for a generic ALWR, then comparing the impact of environmental stressors on that string to their effect on an equivalent instrument string from an existing light-water reactor. The template was then used to suggest a methodology for the qualification of microprocessor-based protection systems. The methodology identifies standards/regulatory guides (or lack thereof) for the qualification of microprocessor-based safety I ampersand C systems. This approach addresses in part issues raised in NRC policy document SECY-91-292, which recognizes that advanced I ampersand C systems for the nuclear industry are ''being developed without consensus standards. as the technology available for design is ahead of the technology that is well understood through experience and supported by application standards.''

  19. Qualification of γ-heating calculation in nuclear reactors

    International Nuclear Information System (INIS)

    Ravaux, Simon

    2013-01-01

    During the last few years, the γ-heating issue has gained in stature, mainly for the safety of the 3. generation reactors in which a stainless steel reflector is inserted. The purpose of this work is the qualification of the needed tools for calculation of the γ-heating in the nuclear reactors. In a nuclear reactor, all the photons are directly or indirectly produced by the neutron-matter interactions. Thus, the first phase of this work is a critical analysis of the photon production data in the standard nuclear data library. New evaluations have been proposed to the next version of the JEFF library after that some omissions have been found. They have partly been accepted for JEFF-3.2. Two particle-transport codes are currently developed in the CEA: the deterministic code APOLLO2 and the Monte Carlo code TRIPOLI4. The second part of this work is the qualification of both these codes by interpreting an integral experiment called PERLE. The experimental set-up is made by a LWR pin assembly surrounded by a stainless steel reflector in which the γ-heating is measured by Thermo-luminescent Detector (TLD). A calculation scheme has been proposed for both APOLLO2 and TRIPOLI4 in order to calculate the TLD's responses. Comparisons between calculations and measurements have shown that TRIPOLI4 gives a satisfactory estimation of the γ-heating in the reflector. These discrepancies are within the experimental 1 σ uncertainty. Before the qualification, APOLLO2 has been previously validated against TRIPOLI4 reference calculation. This validation gives an estimation of the bias due to the deterministic approximations of the transport equation resolution. The qualification has shown that the discrepancies between APOLLO2 predictions and TLD's measurements are in the same range as experimental uncertainties. (author) [fr

  20. Evaluation of the signal-to-noise ratio (SNR) in a CR system and establishment of RQR-M and RQA-M IEC reference radiations in mammography

    International Nuclear Information System (INIS)

    Rosado, Paulo H.G.; Nogueira, Maria S.; Dantas, Marcelino V.A.; Santana, Priscila do C.

    2009-01-01

    In this work, the radiation condition RQR-M e RQA-M of IEC were established in the Siemens Mammomat 3000 mammography equipment. The standard radiation condition are described in terms of: emitting target of molybdenum, percentage ripple not more that 4%, total filtration of 0,032 ± 0,002 mm of molybdenum and specific values of first half-value layer. The results show that the values of parameters were in the range that the IEC recommends. Only the RQAM-3 the value of CSR was not in agreement of the value recommend, and was necessary a additions of 0,1 mm Al in the x-ray tube. After this, the signal noise ratio (SNR) of de Computer radiography (CR) system was evaluated in the reference qualities of RQR-M e RQA-M. For SNR the RQR-M mode of exposure was done with both the 20 mAs and automatic one. To RQA-M the exposure was done with 100 mAs. The variations of the values of SNR were approximated 4%. The tests were done with CR model CR850 made from Kodak and 40 mm of PMMA. (author)

  1. 76 FR 20351 - Federal Acquisition Regulation; Information Collection; Architect-Engineer Qualifications (SF 330)

    Science.gov (United States)

    2011-04-12

    ...; Information Collection; Architect-Engineer Qualifications (SF 330) AGENCIES: Department of Defense (DOD... approve an extension of a currently approved information collection requirement for the Architect-Engineer... Standard Form 330, Part I is used by all Executive agencies to obtain information from architect-engineer...

  2. Unintended Consequences: How Qualification Constrains Innovation

    Science.gov (United States)

    Brice, Craig A.

    2011-01-01

    The development and implementation of new materials and manufacturing processes for aerospace application is often hindered by the high cost and long time span associated with current qualification procedures. The data requirements necessary for material and process qualification are extensive and often require millions of dollars and multiple years to complete. Furthermore, these qualification data can become obsolete for even minor changes to the processing route. This burden is a serious impediment to the pursuit of revolutionary new materials and more affordable processing methods for air vehicle structures. The application of integrated computational materials engineering methods to this problem can help to reduce the barriers to rapid insertion of new materials and processes. By establishing predictive capability for the development of microstructural features in relation to processing and relating this to critical property characteristics, a streamlined approach to qualification is possible. This paper critically examines the advantages and challenges to a modeling-assisted qualification approach for aerospace structural materials. An example of how this approach might apply towards the emerging field of additive manufacturing is discussed in detail.

  3. IEEE Std 649-1980: IEEE standard for qualifying Class 1E motor control centers for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the basic principles, requirements, and methods for qualifying Class 1E motor control centers for outside containment applications in nuclear power generating stations. Qualification of motor control centers located inside containment in a nuclear power generating station is beyond the scope of this standard. The purpose of this standard is (1) to define specific qualification requirements for Class 1E motor control centers in accordance with the more general qualification requirements of IEEE Std 323-1974, IEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations; (2) to provide guidance in establishing a qualification program for demonstrating the design adequacy of Class 1E motor control centers in nuclear power generating station applications

  4. Reliability Prediction Approaches For Domestic Intelligent Electric Energy Meter Based on IEC62380

    Science.gov (United States)

    Li, Ning; Tong, Guanghua; Yang, Jincheng; Sun, Guodong; Han, Dongjun; Wang, Guixian

    2018-01-01

    The reliability of intelligent electric energy meter is a crucial issue considering its large calve application and safety of national intelligent grid. This paper developed a procedure of reliability prediction for domestic intelligent electric energy meter according to IEC62380, especially to identify the determination of model parameters combining domestic working conditions. A case study was provided to show the effectiveness and validation.

  5. Establishment of an unrelated umbilical cord blood bank qualification program: ensuring quality while meeting Food and Drug Administration vendor qualification requirements.

    Science.gov (United States)

    Rabe, Fran; Kadidlo, Diane; Van Orsow, Lisa; McKenna, David

    2013-10-01

    Qualification of a cord blood bank (CBB) is a complex process that includes evaluation of multiple aspects of donor screening and testing, processing, accreditation and approval by professional cell therapy groups, and results of received cord blood units. The University of Minnesota Medical Center Cell Therapy Laboratory has established a CBB vendor qualification process to ensure the CBB meets established regulatory and quality requirements. The deployed qualification of CBBs is based on retrospective and prospective review of the CBB. Forty-one CBBs were evaluated retrospectively: seven CBBs were disqualified based on failed quality control (QC) results. Eight CBBs did not meet the criteria for retrospective qualification because fewer than 3 cord blood units were received and the CBB was not accredited. As of March 2012, three US and one non-US CBBs have been qualified prospectively. One CBB withdrew from the qualification process after successful completion of the comprehensive survey and subsequent failure of the provided QC unit to pass the minimum criteria. One CBB failed the prospective qualification process based on processing methods that were revealed during the paper portion of the evaluation. A CBB qualification process is necessary for a transplant center to manage the qualification of the large number of CBBs needed to support a umbilical cord blood transplantation program. A transplant center that has utilized cord blood for a number of years before implementation of a qualification process should use a retrospective qualification process along with a prospective process. © 2013 American Association of Blood Banks.

  6. Romanian-Canadian joint program for qualification of FCN as a CANDU fuel supplier

    International Nuclear Information System (INIS)

    Galeriu, C.A.; Andrei, G.; Bailescu, A.

    1995-01-01

    RENEL (Romania Power Authority), the co-ordinator of Romanian Nuclear Program, have decided to improve, starting 1990 the existing capability to produce CANDU nuclear fuel at FCN Pitesti. The objective of the program was defined with AAC (AECL - ANSALDO Consortium) for the qualification of FCN fuel plant according to Canadian Z299.2 standard. The Qualification Program was performed under AAC Work Order C-003. The co-ordination was assumed by AECL, as overall Design Authority. ZPI (Zircatec Precision Industries Inc., Canada), were designated to supply technical assistance, equipments and know how where necessary. After a preliminary verification of the FCN fuel plant, including the processes and system investigation, performed under AECL and ZPI assistance, the Qualification Program was defined in all details. The upgrading of documentation on all aspects required by Z299.2 was performed. Few processes needed to be reconsidered and equipment was delivered by ZPI or other suppliers. This includes mainly welding equipments and special inspection equipments. Health Physics was practically fully reconsidered. New equipment and practice were adapted to provide adequate control on health conditions. Every manufacturing and inspection process was checked to determine their performance during a Qualification Run based on acceptance criteria which have been established in the Qualification Plan. Manufacturing Demonstration Run was an important step to prove that all plant functions have been accomplished during the fabrication of 200 fuel bundles. These bundles have been fully accepted and 66 of them have been loaded in the first charge of Unit 1 Cemavoda NPS. The surveillance and audit actions made by AECL and ZPI during this period confirmed the FCN capability to operate an adequate system meeting the to required quality assurance standard. The very open attitude of AECL, Zircatec and FCN staff have stimulated the progress of the project and a successful achievement of the

  7. Qualification and certification of nondestructive testing personnel. Vol. 1

    Energy Technology Data Exchange (ETDEWEB)

    Aly, E A [Quality Assurance Department, national Center for Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    Nondestructive testing and inspection are functions in achieving the goals of quality and efficiency at an acceptable cost. All quality assurance systems necessitate that engineers, technicians and craftsmen are able to demonstrate that they have the required level of knowledge and skill. This applies particularly to nondestructive testing (NDT) and inspection. The paper presented highlights most important national and international standards and guidelines addressing training, qualification and certification of NDT personnel.

  8. Qualification and certification of nondestructive testing personnel. Vol. 1

    International Nuclear Information System (INIS)

    Aly, E.A.

    1996-01-01

    Nondestructive testing and inspection are functions in achieving the goals of quality and efficiency at an acceptable cost. All quality assurance systems necessitate that engineers, technicians and craftsmen are able to demonstrate that they have the required level of knowledge and skill. This applies particularly to nondestructive testing (NDT) and inspection. The paper presented highlights most important national and international standards and guidelines addressing training, qualification and certification of NDT personnel

  9. IEEE 693 seismic qualification of composites for substation high-voltage equipment

    Energy Technology Data Exchange (ETDEWEB)

    Schiff, A.J. [Precision Measurement Instruments, Los Altos Hills, CA (United States); Kempner, L.Jr. [Bonneville Power Administration, Vancouver, BC (Canada)

    2004-07-01

    Standard 693-1997 of the Institute of Electrical and Electronic Engineers (IEEE) is the recommended practice for seismic design of substations. It represents a significant improvement in the way the power industry seismically qualifies substation high-voltage equipment. This paper described the use of IEEE Standard 693 for hollow-core composite insulators that are used on high-voltage transformers and demonstrated that changes are warranted. The following four failure modes associated with the composite insulator were discussed: bond degradation, bond failure, tube degradation and tube layer delamination. The authors evaluated the IEEE 693 qualification procedure of time history shake-table and static-pull tests and were concerned about acceptance criteria. It was shown that acceptance criteria are not valid for qualifying hollow-core composites and that static-pull tests are needed after the vibration qualification tests are completed. It was suggested that more research is warranted to determine if bonding at the top part of the flange can be eliminated, thereby eliminating bond degradation. The resulting increase in system damping would improve the dynamic response of the unit. 1 ref., 10 figs.

  10. Training and qualification program for nuclear criticality safety technical staff. Revision 1

    International Nuclear Information System (INIS)

    Taylor, R.G.; Worley, C.A.

    1997-01-01

    A training and qualification program for nuclear criticality safety technical staff personnel has been developed and implemented. All personnel who are to perform nuclear criticality safety technical work are required to participate in the program. The program includes both general nuclear criticality safety and plant specific knowledge components. Advantage can be taken of previous experience for that knowledge which is portable such as performance of computer calculations. Candidates step through a structured process which exposes them to basic background information, general plant information, and plant specific information which they need to safely and competently perform their jobs. Extensive documentation is generated to demonstrate that candidates have met the standards established for qualification

  11. CALCULATION AND EXPERIMENTAL ESTIMATION OF RESULTS OF ELECTRO-THERMAL ACTION OF RATIONED BY THE INTERNATIONAL STANDARD IEC 62305-1-2010 IMPULSE CURRENT OF SHORT BLOW OF ARTIFICIAL LIGHTNING ON THE THIN-WALLED COVERAGE FROM STAINLESS STEEL

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2017-03-01

    Full Text Available Purpose. Calculation and experimental researches of electro-thermal resistibility of the pre-production thin-walled sheet models of outward roof of height technical buildings from stainless steel are easily soiled 12Х18Н10Т to direct action on them rationed by the International Standard IEC 62305-1-2010 aperiodic impulse of current of short bow of artificial lightning of temporal form 10/350 μs with the proper admittances on his peak-temporal parameters (PTP. Methodology. Electrophysics bases of technique of high voltage and large impulsive currents (LIC, and also scientific and technical bases of planning of high-voltage impulsive devices and measuring methods in them LIC with followings below extreme PTP: amplitude of impulse of current of ImL=200 кА (with admittance ±10 %; integral of action of impulse of current of JL=10·106 A2·s (with admittance ±35 %; %; duration of wavefront current of T1=10 μs (with admittance ±20 %; time, proper amplitude of impulse of current of ImL, tmL≤24 μs (with admittance ±20 %; duration of flowing of impulse of current of T2=350 μs (with admittance ±10 %. Results. The results of evaluation calculation and experimental researches of electro-thermal resistibility of the indicated pre-production sheet models are resulted measuring in the plan of 0,5 x 0,5 m from stainless steel are easily soiled the 12Х18Н10Т thickness of 1 mm to action on them of aperiodic impulse of current of short blow of artificial lightning with rationed PTP on the requirements of the International Standard IEC 62305-1-2010. In high current experiments amplitude of ImL of the aperiodic rationed impulse of current of artificial lightning of temporal form of T1/T2=15 μs/315 μs changed in the range of (100-184 кА. The integral of action of JL of impulse of current for I-IV of levels of protection of lightning of technical objects (TO numeral made from 2,32·106 А2·s to 7,88·106 А2·s, and the flowing through the

  12. On the long-term stability of calibration standards in different matrices.

    Science.gov (United States)

    Kandić, A; Vukanac, I; Djurašević, M; Novković, D; Šešlak, B; Milošević, Z

    2012-09-01

    In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Generation of a plan for the implementation of INTE/ISO IEC 17025 in a paint industry and modification of a quality manual

    International Nuclear Information System (INIS)

    Salazar Gomez, Andrea Marcela

    2014-01-01

    A diagnosis to the integrated management system and quality control laboratories is done in a paint industry. The administrative aspects related with the documentation are evaluated: procedures, instructions, records, processes of sampling, testing, for possible accreditation of some methods of analysis under the norm ISO/IEC 17025 representing an opportunity for growth and improvement in labs. The laboratories of the paint industry have analyzed a number of materials such as products for the various stages of construction and beautification of homes, buildings and other, as well as evaluation of the requirements established by international standards to demonstrate competence regarding these. The feasibility of implementing the standard is visualized, solving the disagreements that have been found during the evaluation period. The impact of the perception of quality is determined by the direction, the need for investment in resources, training and equipment. (author) [es

  14. Tailoring ISO/IEC 27001 for SMEs: A Guide to Implement an Information Security Management System in Small Settings

    Science.gov (United States)

    Valdevit, Thierry; Mayer, Nicolas; Barafort, Béatrix

    While Information Security Management Systems (ISMS) are being adopted by the biggest IT companies, it remains quite difficult for smaller entities to implement and maintain all the requirements of ISO/IEC 27001. In order to increase information security in Luxembourg, the Public Research Centre Henri Tudor has been charged by the Luxembourg Ministry of Economy and Foreign Trade to find solutions to facilitate ISMS deployment for SMEs. After an initial experiment aiming at assisting a SME in getting the first national ISO/IEC 27001 certification for a private company, an implementation guide for deploying an ISMS, validated by local experts and experimented in SMEs, has been released and is presented in this paper.

  15. Qualification test and analysis report: solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    Test results show that the Owens-Illinois Sunpak/sup TM/ Model SEC 601 air-cooled collector meets the national standards and codes as defined in the Subsystem Performance Specification and Verification Plan of NASA/MSFC Contract NAS8-32259, dated October 28, 1976. The architectural and engineering firm of Smith, Hinchman and Grylls, Detroit, Michigan, acted in the capacity of the independent certification agency. The program calls for the development, fabrication, qualification and delivery of an air-liquid solar collector for solar heating, combined heating and cooling, and/or hot water systems.

  16. Cylindrical IEC neutron source design for driven research reactor operation

    International Nuclear Information System (INIS)

    Miley, G.H.; Ulmen, B.; Amadio, G.; Leon, H.; Hora, H.

    2009-01-01

    A resurgence in nuclear power use is now underway worldwide. However, due many university research reactors shutdown, they must rely on using subcritical assemblies which employs a cylindrical Inertial Electrostatic Confinement (IEC) device to provide a fusion neutron source. The source is inserted in a fuel element position, with its power input controlled externally at a control panel. This feature opens the way to use of the critical assembly for a number of transient experiments such as sub-critical pulsing and neutron wave propagation. That in turn adds important new insights and excitement for the student teaching laboratory. (author)

  17. Experience with nuclear safety standards development in non-governmental international organizations

    International Nuclear Information System (INIS)

    Becker, K.

    1985-01-01

    Besides the IAEA as a 'governmental' organization dealing with basic safety recommendations addressed primarily to the national regulatory bodies in developing countries, two closely related non-governmental international standards organizations have gained extensive experience in the field of nuclear standardization. Over more than 25 years since their formation, both (a) the International Organization for Standardization's (ISO) Technical Committee 85 'Nuclear Energy', in particular in its Sub-Committee 3 'Reactor Technology and Safety' and (b) the International Electrotechnical Commission's (IEC) Technical Committee 45 'Nuclear Instrumentation' have published numerous standards. A brief review is given of these, draft standards, and other documents planned to become international standards. Many of them deal with rather specialized topics typical for 'industrial' standards such as standardized procedures, instruments, methods, materials, test methods, terminology, and signs and symbols, but others are directly related to more basic safety issues. In some areas such as quality assurance, seismic aspects of siting and terminology, there has been in the past occasional overlap in the activities of the NUSS programme, IEC and ISO. Letters of Understanding have since 1981 contributed to clarifying the borderlines and to avoiding redundant efforts. Also, some experiences and problems are described arising, for example, from the harmonization of different national safety philosophies and traditions into universally accepted international standards, and the transfer of international standards into national standards systems. Finally, based on a recent comprehensive compilation of some 3300 nuclear standards and standards projects, an attempt is made to present a cost/benefit analysis and an outlook on future developments. (author)

  18. Overview of nuclear power plant equipment qualification issues and practices

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report presents a view of and commentary on the current status of equipment qualification (EQ) in nuclear industries of the major western nations. The introductory chapters discuss the concepts of EQ, the elements of EQ process and highlight some of the key issues in EQ. A brief review of industry practices and some of the prevalent industrial standards is presented, followed by an overview of current regulatory positions in the USA, France, Germany and Sweden. A summary and commentary on the latest research findings on issues relating to accident simulation, to aging simulation and some special topics related to EQ, has been contributed by Franklin Research Centre of Philadelphia. The last part of the report deals with equipment qualification in Canada and gives recommendations on EQ for new plants as well as currently operational CANDU nuclear power plants

  19. Nuclear energy electricity technical regulation on the qualification

    International Nuclear Information System (INIS)

    1995-01-01

    It tells the range of application purpose and of the qualification. It describes how to qualify of the class 1 E equipment, which are type test, operating experience, analysis and combined method. Next it deals with qualification procedure, which are specification requirement, requirement of qualification program, type testing, operating experience, analysis and combined qualification, acceptance criteria modification and extension with qualified life, simulated test profiles and document about type test data, operating experience data and extrapolation.

  20. Changing existing qualifications into outcomes-based qualifications ...

    African Journals Online (AJOL)

    Various workshops were facilitated to determine the outcomes of each level of our qualification, B Tech: Policing. This led to the formulation of a purpose statement, exit level outcomes and specific outcomes as well as assessment criteria and the critical outcomes embedded in each level identified. Using the specific ...

  1. 48 CFR 1553.209 - Contractor qualifications.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Contractor qualifications. 1553.209 Section 1553.209 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY CLAUSES AND FORMS FORMS Prescription of Forms 1553.209 Contractor qualifications. ...

  2. On relaxing the Mangasarian-Fromovitz constraint qualification

    Czech Academy of Sciences Publication Activity Database

    Kruger, A.Y.; Minchenko, L.; Outrata, Jiří

    2014-01-01

    Roč. 18, č. 1 (2014), s. 171-189 ISSN 1385-1292 R&D Projects: GA ČR GAP402/12/1309 Institutional support: RVO:67985556 Keywords : Nonlinear programming * Regularity conditions * Constraint qualifications * Lagrange multipliers * Mangasarian–Fromovitz constraint qualification * Constant rank constraint qualification Subject RIV: BA - General Mathematics Impact factor: 0.679, year: 2014 http://library.utia.cas.cz/separaty/2014/MTR/outrata-0426110.pdf

  3. 5 CFR 317.502 - Qualifications Review Board certification.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS EMPLOYMENT IN THE SENIOR EXECUTIVE SERVICE Career Appointments § 317.502 Qualifications Review Board certification. (a) A Qualification Review Board (QRB) convened by OPM must certify the executive... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Qualifications Review Board certification...

  4. Nuclear Criticality Safety Department Qualification Program

    International Nuclear Information System (INIS)

    Carroll, K.J.; Taylor, R.G.; Worley, C.A.

    1996-01-01

    The Nuclear Criticality Safety Department (NCSD) is committed to developing and maintaining a staff of highly qualified personnel to meet the current and anticipated needs in Nuclear Criticality Safety (NCS) at the Oak Ridge Y-12 Plant. This document defines the Qualification Program to address the NCSD technical and managerial qualification as required by the Y-1 2 Training Implementation Matrix (TIM). This Qualification Program is in compliance with DOE Order 5480.20A and applicable Lockheed Martin Energy Systems, Inc. (LMES) and Y-1 2 Plant procedures. It is implemented through a combination of WES plant-wide training courses and professional nuclear criticality safety training provided within the department. This document supersedes Y/DD-694, Revision 2, 2/27/96, Qualification Program, Nuclear Criticality Safety Department There are no backfit requirements associated with revisions to this document

  5. AREVA advanced safety IC solutions and licensing experience for new nuclear builds and modernization projects - 15545

    International Nuclear Information System (INIS)

    Fourestie, B.; Pickelmann, J.; Richter, S.; Hilsenkopf, P.; Paris, P.

    2015-01-01

    Regulatory requirements for the Instrumentation and Control (IC) for Nuclear Power Plants have become significantly more stringent during the last 10 years in the areas of software development and qualification, traceability, diversity, or seismic requirements for instance, and with the introduction of new standards (such as the IEC 62566, or the IEC 62003). Based on a large and comprehensive experience gained from projects in several regulatory environments and different plant types (including non-OEM plants), AREVA has developed and adapted its processes and products to provide state-of-the-art IC solutions in full compliance with the regulatory demands and requirements in terms of robustness (independence, defense-in-depth, diversity and cyber-security). In this paper we present the safety IC platforms developed by AREVA. These platforms include TELEPERM XS as the computerized safety IC platform for class 1 system implementation, the Qualified Display System (QDS) for safety classified screen-based interface, and UNICORN as fully diverse analog safety IC platform for backup systems

  6. Development of standard technical report on using and selecting wireless device in nuclear power plants

    International Nuclear Information System (INIS)

    Koo, I. S.; Hong, S. B.; Cho, J. W.

    2011-11-01

    1. Purpose · Development of IEC technical report on wireless device using in nuclear power plants 2. Contents · IEC technical reports of draft for circulation and final draft for next planary meeting · Case study on experiment of wireless devices 3. Implementation methods · Preparation of first draft with experts group, its circulation, discussions on the results of the circulation · Organizing three teams such as preparation, reviews and experiment 4. Results · Maintenance cost will be reduced with application of the wireless technologies in nuclear power plants · Commercial wireless devices will be developed before standard is issued

  7. 48 CFR 53.209 - Contractor qualifications.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Contractor qualifications. 53.209 Section 53.209 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS Prescription of Forms 53.209 Contractor qualifications. ...

  8. Software life cycle management standards real-world solutions and scenarios for savings

    CERN Document Server

    Wright, David

    2011-01-01

    Software Life Cycle Management Standards will help you apply ISO/IEC 19770 to your business and enjoy the rewards it offers. David Wright calls on his vast experience to explain how the Standard applies to the whole of the software life cycle, not just the software asset management aspects. His informative guide gives up-to-date information using practical examples, clear diagrams and entertaining anecdotes.

  9. Skill qualifications in pediatric minimally invasive surgery.

    Science.gov (United States)

    Iwanaka, Tadashi; Morikawa, Yasuhide; Yamataka, Atsuyuki; Nio, Masaki; Segawa, Osamu; Kawashima, Hiroshi; Sato, Masahito; Terakura, Hirotsugu; Take, Hiroshi; Hirose, Ryuichiro; Yagi, Makoto

    2011-07-01

    In 2006, The Japanese Society of Pediatric Endoscopic Surgeons devised a plan to develop a pediatric endoscopic surgical skill qualification (ESSQ) system. This system is controlled by The Japan Society for Endoscopic Surgery. The standard requirement for skills qualification is the ability of each applicant to complete common types of laparoscopic surgery. The main goal of the system is to decrease complications of laparoscopic surgery by evaluating the surgical skills of each applicant and subsequently certify surgeons with adequate skills to perform laparoscopic operations safely. A committee of pediatric ESSQ created a checklist to assess the applicant's laparoscopic surgical skills. Skills are assessed in a double-blinded fashion by evaluating an unedited video recording of a fundoplication for pediatric gastroesophageal reflux disease. The initial pediatric ESSQ system was started in 2008. In 2008 and 2009, respectively, 9 out of 17 (53%) and 6 out of 12 (50%) applicants were certified as expert pediatric laparoscopic surgeons. Our ultimate goal is to provide safe and appropriate pediatric minimally invasive procedures and to avoid severe complications. To prove the predictive validity of this system, a survey of the outcomes of operations performed by certified pediatric surgeons is required.

  10. Excerpt from: Testing of radiotherapy dosimeters in accordance with specifications given by IEC publication 731 (1982)

    International Nuclear Information System (INIS)

    Jaervinen, Hannu; Rantanen, Erkii; Jokela, Kari

    1986-01-01

    In their position as centres for expertise in radiation dosimetry and its applications, the Secondary Standard Dosimetry Laboratories (SSDLs) are expected to advise the radiation users, the radiotherapy centres in particular, in selection and use of the most suitable dosimetric equipment. Various dosimeters are commercially available, but objective information on their fundamental technical characteristics is lacking. Such information would be valuable and necessary for the SSDLs to be able to judge the accuracy and reliability of the many choices which exist for a given application. The results of systematic evaluations of dosimeters in a recognized SSDL (or SSDLs) could be helpful supplementary information to the other SSDLs and to the radiation users. In 1983 The Finnish Centre for Radiation and Nuclear Safety (STUK; old name: Institute of Radiation Protection) and the International Atomic Energy Agency (IAEA) made a research contract, the purpose of which was to test selected dosimeters for use in radiotherapy in accordance with the specifications by the International Electrotechnical Commission (IEC)

  11. Environmental Qualification Program for NPP Krsko

    International Nuclear Information System (INIS)

    Cerjak, J.; Klenovsek, P.; Pavsek, J.; Spalj, S.; Colovic, G.

    1998-01-01

    The functionality the equipment important to safety is deteriorated during its service due to ageing and harsh environment conditions. Since the environment is a potential for common cause failures, the purpose of Environmental Qualification (EQ) is to demonstrate the capability of safety-related equipment to perform its safety function in aged conditions and under extreme conditions after design bases event (DBE). EQ is one of the steps in licensing process according to US regulatory documents and standards (10CFR50.49, RG 1.89, NUREG-0588, IEEE-323). This paper presents the efforts in establishing the EQ program in the Krsko nuclear power plant. (author)

  12. Qualification tests for a dosimetry system

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    The report of qualification tests for personnel dosemeters is detailed. Qualification test for the energy response and the incidence angle is given. The procedure of test is resumed. Different coefficients of conversion used in these tests are given in tables. (N.C.)

  13. 48 CFR 253.209 - Contractor qualifications.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Contractor qualifications. 253.209 Section 253.209 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CLAUSES AND FORMS FORMS Prescription of Forms 253.209 Contractor qualifications. ...

  14. Characterization of a PET-NEMA/IEC body phantom for quality control tests of PET/CT equipment

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Vieira, Igor F.; Lima, Fernando R.A.; Sa, Lidia V. de

    2011-01-01

    The Brazilian Sanitary Agency from Ministry of Health requires that all PET/CT equipment must undergo minimal quality control tests using manufacturer simulators. The PET-NEMA/IEC body phantom is recommended by the IEC and NEMA to perform acceptance testing and quality control in PET/CT equipment according to specific protocols. It is essential that all simulator components (spheres and body) are properly characterized in relation to their size and internal structure volumes, since they are used to calculate the overall activity concentration and the total weight. The objective of this work was characterize a PET-NEMA/IEC body phantom for the true reconstruction in computational modeling and correct analysis of experimental results. The simulator is basically composed of three structures: the body (simulating a portion of the chest), an inner cylinder (simulating the lung tissue) and a top cover in which are coupled spheres of different sizes simulating 'hot' (tumors) and cold lesions. The spheres were evaluated in terms of volume. The same evaluations were performed with the body of the simulator and the inner cylinder, beyond of analysis of their weights (filled with water) and wall thickness. The data showed that the total weight of the simulator with all its internal structures is 12.5 kg and the volume of the 'hot' and 'cold' spheres are approximately equal to those presented by the manufacturer. The inner cylinder volume showed a significant difference between the measured and the presented in the manual. The results were used for reconstruction of the simulator in computational modeling using the code GATE. (author)

  15. Inspection qualification and implementation of ENIQ in Sweden

    International Nuclear Information System (INIS)

    Zettervall, Tommy

    2013-01-01

    Many countries are currently considering their approaches to inspection qualification and risk-informed in-service inspection (RI-ISI) and are carefully assessing experience data. In Europe most of the utilities operating nuclear power plants have joined together to form the European Network for Inspection Qualification ENIQ. In practice, qualification can be performed with varying degrees of complexity and cost, varying from capability statement based on existing evidence, through to an extensive qualification consisting of a detailed Technical Justification (TJ) together with open and blind trials on full-scale test blocks. An Inspection Qualification is an investigation and demonstration, which confirm that an inspection system has the ability to solve its specific tasks. The qualification is a Quality Assurance of an inspection system based on documents and practical trials. A reliable inspection system, based on a reliable qualification and correct prerequisites, will reduce total costs for Licensees and increase the credibility of the inspection result. To get such inspection system, which could be valid for many years, it's of necessity to fulfil all included parts in the process. It begins with the Technical Specification from Licensee, where input data and requirements about the actual component are specified. To get an inspection system that could live over time, the Technical Justification is of importance. Finally the test blocks and used simulation techniques play an important part of the final result, and these test blocks together with TJ form the basis for qualification body's decision. (author)

  16. Qualification of NDT techniques for in-service inspections in nuclear power plants in accordance with ENIQ - examples and lessons - learned

    International Nuclear Information System (INIS)

    Just, T.; Csapo, G.

    2006-01-01

    ENIQ (European Network for Inspection and Qualification) has developed regulations on how to qualify non-destructive testing (NDT) methods and techniques in a standardized and structured manner. Two major innovative qualifications were carried out and reviewed with regard to implementation, according to the recommended German practice of ENIQ. The conclusions were drawn after performing the ENIQ qualification procedure for in-service inspections (ISI) of real components in nuclear power plants (NPP). The first example covers the qualification of NDT methods for the detection and characterization of surface, subsurface and underclad cracks in the area of the austenitic cladded RPV surface. Open and blind tests were conducted applying UT and ET (from the ID) and UT (from the OD) on realistic flaws (artificially induced IGSCC, hot cracks and fatigue cracks) in the cladding of a full scale RPV mock-up from MPA Stuttgart. The second example covers the qualification of mechanised RT in combination with tomography (developed by the BAM) for the sizing of cracks in pipe welds. For both qualification procedures TUEV NORD SysTec experts were part of the qualification body. The proposed NDT procedures have been qualified within defined limits of application. Recommendations were made to optimise the procedures and the techniques itself further. (orig.)

  17. Standard compliance - NDE performance demonstration/inspection in the CANDU industry

    International Nuclear Information System (INIS)

    Choi, E.

    2011-01-01

    CANDU nuclear power plants are operated in 3 provinces in Canada for electric power generation. A table in the paper will show the built and operating plants in Ontario, Quebec, New Brunswick and overseas. The regulator for nuclear power in Canada is the Canadian Nuclear Safety Commission (CNSC). The CNSC holds the plant licensees accountable for compliance to CSA N285.4 for periodic inspections. The Standard basically specifies the 'what, when, where, how, how much and how frequently' NDE is to be done on pressure retaining systems and components in CANDU nuclear power plants. In inspection methods, the Standard specifies they must be non-destructive. The NDE methods were grouped into visual, dimensional, surface, volumetric and integrative. The Standard also specifies that the licensees are responsible for the performance demonstration (PD) of the adequacy of the procedures and the proficiency of the personnel. This paper describes the Standard's requirement in NDE qualification and presents a joint project participated by Canadian and overseas CANDU owners. The sub-project for NDE included providing evidence and technical justification on the adequacy of the procedures and the proficiency of the personnel. The paper describes the qualification methodology followed by the participants. This will be followed by how the participants produced Inspection Specification, tools and procedures, personnel training and qualification programs, test and qualification samples, independent peer reviews and Technical Justification. (author)

  18. Equipment qualification testing - a practical approach

    International Nuclear Information System (INIS)

    Davies, G.A.; McDougall, R.I.; Poirier, M.P.

    1996-01-01

    When nuclear safety equipment is credited with a Required Safety Function it must properly perform that function to facilitate safe control and/or shutdown of the plant during a design basis accident. When such equipment is required to be environmentally (EQ) and/or seismically qualified (SQ) for safety related use in CANDU nuclear power plants, the preferred method of qualification is by type testing. The qualification testing process requires that the test specimen equipment be subjected to the aging stressors associated with the normal service conditions that it would experience during it's required qualified (or service) life. Following the aging process, the test specimen is in a condition representative of that in which it would be at the end of its service life in the plant. The test specimen is then subjected to a simulated accident during which it must satisfy performance requirements thereby demonstrating that it can perform its required safety function. The performance requirements specified for the qualification testing must be designed to ensure that satisfactory performance of the safety function is demonstrated during the qualification program. This paper provides descriptions of practical methods used in the deriving and satisfying of relevant performance requirements during the qualification testing of safety related equipment. (author)

  19. Excellence in fleet combat replacement squadrons: predicting carrier qualification success

    OpenAIRE

    Smith, Martin P.

    1988-01-01

    This thesis presents a two-part analysis of excellence criteria for fleet combat replacement squadrons. Part one focuses on the qualitative issues and management techniques identified in outstanding fleet combat replacement squadrons. Part two develops and presents a regression model for predicting a fleet replacement squadron pilot's carrier qualification grade. The model was derived using standard linear regression techniques and the SPSSx software package of the Naval Postgraduate School. ...

  20. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    Science.gov (United States)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-04-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented.

  1. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    International Nuclear Information System (INIS)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-01-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented

  2. Total qualification of class 1E electric equipment

    International Nuclear Information System (INIS)

    Chauvin, G.

    1982-09-01

    For nuclear power plant projects in France, Framatome and its partners Electricite de France (EDF) and the Commissariat a l'Energie Atomique (CEA) have responded to the present qualification context by implementing a wide-ranging qualification program to acquire significant organizational and practical experience. The following sections detail Framatome's approach to the activities of an organization mandated to provide a complete spectrum of qualification services. Thorough implementation of a Class 1E electric equipment qualification program by the competent organization or qualifier entails completion of three consecutive steps: 1) program preparation, 2) program implementation, and 3) analysis of test results and conclusion. The qualifier assumes extensive responsibility for each of these steps. The following sections present test facilities used in France to conduct a total qualification program for Class 1E electric equipment

  3. Qualification criteria for persons responsible for radiation protection

    International Nuclear Information System (INIS)

    Wehner, G

    1980-01-01

    A survey of the qualification criteria included in the German atomic law (Atomic Energy Act, Radiological Protection Ordinance and X-ray Protection Ordinance) for persons responsible for radiation protection is given. Especially the various activities for which a health physics officer is required, the range of qualification in each case and the way the qualification has to be proved, are pointed out. Also the different guides that are issued to complete the legal requirements are mentioned. The definitions of the term qualification for health physics given in the different guides are cited and it is shown, that the qualification of a healt physics officer has to be based on the three criteria (I) vocational training. (II) professional experience and (III) the necessary knowledge in radiation protection. (orig./HP) [de

  4. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  5. Implementation of IEC Generic Model of Type 1 Wind Turbine Generator in DIgSILENT PowerFactory

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Margaris, Ioannis

    2013-01-01

    The implementation method for the International Electrotechnical Commission (IEC) generic models of Type 1 wind turbine generator (WTG) in DIgSILENT PowerFactory is presented. The following items are described, i.e. model structure, model blocks and how to implement these blocks in the PowerFactory...

  6. Chapter No.8. Personnel qualification and training

    International Nuclear Information System (INIS)

    2002-01-01

    selected personnel were scheduled according to the plan of examining committee meetings. For each examined person written tests are generated by the computer from the database of test questions at the Training Centre of VUJE Trnava for individual positions - categories of selected staff of NPP V-1 and NPP V-2 Bohunice and NPP Mochovce so that the examination questions both in written and oral part equally cover individual facilities and regimes of operation of NPP. The database is continuously updated, thereby containing new questions resulting from the recent changes carried out at NPP's. A part of the examination in case of promotion to a higher position is the practical part, which is conducted under the direct supervision of the trainer within 4 to 10 weeks after the successful completion of both written and oral of examinations. Last year the committee held ten sessions for the oral theoretical examination. The number of licenses issued in 2001 and the total number of valid licenses is given. Conclusions from inspections and tests as well as results from operation and start up of nuclear units confirm that in this area a high standard of operational safety is being achieved on a permanent basis. Increasing the qualification of UJD staff Increasing the qualification of UJD staff was done in a form of training and courses scheduled in the plan of training for UJD staff for 2001. This training composed of specialised qualification study, functional study, as well as study aimed at maintaining qualification (continual and periodical exercise). Training courses organised by the Government Office of Slovakia and the IAEA were also of a significant benefit and UJD staff participated on foreign training courses, seminars and conferences, focusing on maintaining and improvement of professional skills

  7. The comparison of System 1000 analysis and type testing for neoprene gasket environmental qualification

    International Nuclear Information System (INIS)

    Park, Kyung Heum; Kim, Jong Seok; Jeong, Sun Chul; Jang, Kyung Nam; Hwang, Sung Phil

    2010-01-01

    The typical environmental qualification is to ensure that equipment will operate on demand to meet system performance requirements during normal and abnormal service conditions. There are four environmental qualification methods, type testing, operating experience, analysis and combined method. Generally, the American EQ do not contain the mechanical equipment like pumps and valves in their EQ equipment list because their EQ standard 10CFR50.49 limits EQ equipment as electrical equipment. On the other hand, Canadian EQ contain the mechanical equipment like pumps and valves in their EQ components list, Canadians usually call American 'equipment' as 'components', because their EQ standard CSA N290.13-05 do not limits EQ equipment as electrical equipment. System 1000 program is typical Canadian EQ analysis method using mathematical modeling and comparison with established engineering information and manufacturers' data. Most of Canadian nuclear power utilities like NB Power, Hydro Quebec and OPG use the System 1000 program to evaluate the design life for their EQ components. To qualify a pump, I had to list all the non-metallic parts in the pump and found there are lots of gaskets made by neoprene material. I tried to qualify these neoprene gaskets by analysis using System 1000 program and by type testing. In this paper, I'd like to introduce the qualification results of neoprene gasket both type testing and analysis using System 1000 program

  8. Protective Effect of Wheat Peptides against Indomethacin-Induced Oxidative Stress in IEC-6 Cells

    Directory of Open Access Journals (Sweden)

    Hong Yin

    2014-01-01

    Full Text Available Recent studies have demonstrated that wheat peptides protected rats against non-steroidal anti-inflammatory drugs-induced small intestinal epithelial cells damage, but the mechanism of action is unclear. In the present study, an indomethacin-induced oxidative stress model was used to investigate the effect of wheat peptides on the nuclear factor-κB(NF-κB-inducible nitric oxide synthase-nitric oxide signal pathway in intestinal epithelial cells-6 cells. IEC-6 cells were treated with wheat peptides (0, 125, 500 and 2000 mg/L for 24 h, followed by 90 mg/L indomethacin for 12 h. Wheat peptides significantly attenuated the indomethacin-induced decrease in superoxide dismutase and glutathione peroxidase activity. Wheat peptides at 2000 mg/L markedly decreased the expression of the NF-κB in response to indomethacin-induced oxidative stress. This study demonstrated that the addition of wheat peptides to a culture medium significantly inhibited the indomethacin-induced release of malondialdehyde and nitrogen monoxide, and increased antioxidant enzyme activity in IEC-6 cells, thereby providing a possible explanation for the protective effect proposed for wheat peptides in the prevention of indomethacin-induced oxidative stress in small intestinal epithelial cells.

  9. Seismic qualification of equipment for the TA-55 Plutonium Processing Facility

    International Nuclear Information System (INIS)

    Pellette, P.R.; Endebrock, E.G.; Giles, P.M.; Shaw, R.H.

    1977-04-01

    The techniques employed by the Los Alamos Scientific Laboratory (LASL) for the seismic qualification of internal equipment for the TA-55 Plutonium Facility are discussed. The structural analysis of the plutonium building and critical associated structures was performed by the Architect-Engineer (A-E), and the calculations were checked by LASL. The specifications and procedures used by LASL produced dramatic improvement in the responses by qualified vendors to the seismic requirements. There was an increase from about a 20% bid ratio to greater than 90% because prospective vendors could be competitive without having had previous seismic experience with their equipment. The equipment seismic qualification for TA-55 is in compliance with the Code of Federal Regulations, Nuclear Regulatory Commission (NRC) Guides, Energy Research and Development Administration (ERDA) Manual Chapters and Appendices, and Institute of Electrical and Electronic Engineers (IEEE) Standard 344

  10. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  11. Solar array qualification through qualified analysis

    Science.gov (United States)

    Zijdemans, J.; Cruijssen, H. J.; Wijker, J. J.

    1991-04-01

    To achieve qualification is in general a very expensive exercise. For solar arrays this is done by a dedicated test program through which final qualification is achieved. Due to severe competition on the solar array market, cheaper means are looked for to achieve a qualified product for the customers. One of the methods is to drastically limit the environmental test program and to qualify the solar-array structure against its environmental loads by analysis. Qualification by analysis is possible. The benefits are that a significant amount of development effort can be saved in case such a powerful tool is available. Extensive testing can be avoided thus saving time and money.

  12. A novel strategy with standardized reference extract qualification and single compound quantitative evaluation for quality control of Panax notoginseng used as a functional food.

    Science.gov (United States)

    Li, S P; Qiao, C F; Chen, Y W; Zhao, J; Cui, X M; Zhang, Q W; Liu, X M; Hu, D J

    2013-10-25

    Root of Panax notoginseng (Burk.) F.H. Chen (Sanqi in Chinese) is one of traditional Chinese medicines (TCMs) based functional food. Saponins are the major bioactive components. The shortage of reference compounds or chemical standards is one of the main bottlenecks for quality control of TCMs. A novel strategy, i.e. standardized reference extract based qualification and single calibrated components directly quantitative estimation of multiple analytes, was proposed to easily and effectively control the quality of natural functional foods such as Sanqi. The feasibility and credibility of this methodology were also assessed with a developed fast HPLC method. Five saponins, including ginsenoside Rg1, Re, Rb1, Rd and notoginsenoside R1 were rapidly separated using a conventional HPLC in 20 min. The quantification method was also compared with individual calibration curve method. The strategy is feasible and credible, which is easily and effectively adapted for improving the quality control of natural functional foods such as Sanqi. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Interim staff position on environmental qualification of safety-related electrical equipment: including staff responses to public comments. Regulatory report

    International Nuclear Information System (INIS)

    Szukiewicz, A.J.

    1981-07-01

    This document provides the NRC staff positions regarding selected areas of environmental qualification of safety-related electrical equipment, in the resolution of Unresolved Safety Issue A-24, 'Qualification of Class IE Safety-Related Equipment.' The positions herein are applicable to plants that are or will be in the construction permit (CP) or operating license (OL) review process and that are required to satisfy the requirements set forth in either the 1971 or the 1974 version of IEEE-323 standard

  14. Chemical chaperones reduce ionizing radiation-induced endoplasmic reticulum stress and cell death in IEC-6 cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sang; Lee, Hae-June; Lee, Yoon-Jin [Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Jeong, Jae-Hoon [Division of Radiotherapy, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Kang, Seongman [Division of Life Sciences, Korea University, Seoul 136-701 (Korea, Republic of); Lim, Young-Bin, E-mail: yblim@kirams.re.kr [Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of)

    2014-07-25

    Highlights: • UPR activation precedes caspase activation in irradiated IEC-6 cells. • Chemical ER stress inducers radiosensitize IEC-6 cells. • siRNAs that targeted ER stress responses ameliorate IR-induced cell death. • Chemical chaperons prevent cell death in irradiated IEC-6 cells. - Abstract: Radiotherapy, which is one of the most effective approaches to the treatment of various cancers, plays an important role in malignant cell eradication in the pelvic area and abdomen. However, it also generates some degree of intestinal injury. Apoptosis in the intestinal epithelium is the primary pathological factor that initiates radiation-induced intestinal injury, but the mechanism by which ionizing radiation (IR) induces apoptosis in the intestinal epithelium is not clearly understood. Recently, IR has been shown to induce endoplasmic reticulum (ER) stress, thereby activating the unfolded protein response (UPR) signaling pathway in intestinal epithelial cells. However, the consequences of the IR-induced activation of the UPR signaling pathway on radiosensitivity in intestinal epithelial cells remain to be determined. In this study, we investigated the role of ER stress responses in IR-induced intestinal epithelial cell death. We show that chemical ER stress inducers, such as tunicamycin or thapsigargin, enhanced IR-induced caspase 3 activation and DNA fragmentation in intestinal epithelial cells. Knockdown of Xbp1 or Atf6 with small interfering RNA inhibited IR-induced caspase 3 activation. Treatment with chemical chaperones prevented ER stress and subsequent apoptosis in IR-exposed intestinal epithelial cells. Our results suggest a pro-apoptotic role of ER stress in IR-exposed intestinal epithelial cells. Furthermore, inhibiting ER stress may be an effective strategy to prevent IR-induced intestinal injury.

  15. Study on AC loss measurements of HTS power cable for standardizing

    Science.gov (United States)

    Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi

    2017-09-01

    High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..

  16. Approach to customer qualification of the BNFL Sellafield Mox Plant

    International Nuclear Information System (INIS)

    Sullivan, P.

    2003-01-01

    BNFL started plutonium commissioning of its Sellafield MOX Plant (SMP) in December 2001, with the first MOX pellets being produced in May 2002. SMP was designed to manufacture a range of both PWR and BWR fuel types for a number of different customers. During commissioning and early MOX fuel manufacturing BNFL has been demonstrating its ability to both automatically manufacture and inspect MOX fuel to meet the requirements of different customers' specifications and fuel types. The qualification project consisted of common and project specific qualification. Common qualification was carried out to demonstrate BNFL could meet several customers' requirements during the same qualification test. Project specific qualification was carried out for one customer only as the fabrication or inspection equipment was specific to their fuel type. An example is the fuel assembly process. The reasons for BNFL carrying out common qualification were: - Develop a common qualified process to meet different customer specifications. - Minimise future qualifications prior to starting future fuel campaigns. - Ensure BNFL understands and effectively manages different customer requirements in SMP. BNFL has approached qualification of SMP systematically. Firstly the inspection system was qualified, and once completed the inspection system was then used in the qualification of the manufacturing process. (orig.)

  17. 49 CFR 214.351 - Training and qualification of flagmen.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Training and qualification of flagmen. 214.351... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection § 214.351 Training and qualification of flagmen. (a) The training and qualification for roadway workers assigned the...

  18. Results of a literature review on the environmental qualification of low-voltage electric cables

    International Nuclear Information System (INIS)

    Lofaro, R.; Lee, B.; Villaran, M.; Gleason, J.; Aggarwal, S.

    1995-01-01

    In the design of nuclear power plants in the US, safety-related electric equipment must be qualified to provide reasonable assurance it can withstand the effects of a design basis event (DBE) and still be able to perform its prescribed safety function, even if the accident were to occur at the end of its service life. The requirement for environmental qualification (EQ) originates from the General Design Criteria in the Code of Federal Regulations, Title 10, Part 50 (10 CFR 50). The acceptable method of performing the qualification of this equipment has evolved over the years, starting with the NRC Division of Operating Reactors (DOR) Guidelines, which were issued in Bulletin 79--01B, and NUREG-0588 requirements and ending with the current EQ Rule, 10 CFR 50.49. While the EQ methods described in these documents have the same overall objective, there are some notable differences for which a clear technical basis has not been established. One difference is the preaging requirement for equipment prior to LOCA testing. In addition, specific issues related to current EQ practices have been raised by the US NRC which need to be addressed. These issues, which are discussed in detail later in this paper, are related to the sources of conservatism and uncertainty in IEEE Standard 323--1974, which is the qualification standard currently endorsed by the NRC. To address these issues, the NRC Office of Nuclear Reactor Regulation (NRR) implemented a Task Action Plan (TAP), and the Office of Nuclear Reactor Research (RES) initiated a complementary research program. The current focus of this program is on the qualification of low-voltage instrumentation and control cables. These cables were selected since they are not typically replaced on a routine basis, and their degradation could impact plant safety

  19. Cytoprotective effects of essential oil of Pinus halepensis L. against aspirin-induced toxicity in IEC-6 cells.

    Science.gov (United States)

    Bouzenna, Hafsia; Hfaiedh, Najla; Bouaziz, Mouhamed; Giroux-Metges, Marie-Agnès; Elfeki, Abdelfattah; Talarmin, Hélène

    2017-12-01

    Essential oils from Pinus species have been reported to have various therapeutic properties. This study was undertaken to identify the chemical composition and cytoprotective effects of the essential oil of Pinus halepensis L. against aspirin-induced damage in cells in vitro. The cytoprotection of the oil against toxicity of aspirin on the small intestine epithelial cells IEC-6 was tested. The obtained results have shown that 35 different compounds were identified. Aspirin induced a decrease in cell viability, and exhibited significant damage to their morphology and an increase in superoxide dismutase (SOD) and catalase (CAT) activities. However, the co-treatment of aspirin with the essential oil of Pinus induced a significant increase in cell viability and a decrease in SOD and CAT activities. Overall, these finding suggest that the essential oil of Pinus halepensis L. has potent cytoprotective effect against aspirin-induced toxicity in IEC-6 cells.

  20. Qualification testing facility for packages to be used for transport and storage of radioactive materials

    International Nuclear Information System (INIS)

    Vieru, Gheorghe

    2009-01-01

    The radioactive materials (RAM) packaging have to comply to all modes and transport condition, routine or in accident conditions possibly to occur during transportation operations. It is well known that the safety in the transport of RAM is dependent on packaging appropriate for the contents being shipped rather than on operational and/or administrative actions required for the package. The quality of these packages - type A, B or C has to be proved by performing qualification tests in accordance with the ROMANIAN nuclear regulation conditions provided by CNCAN Order no. 357/22.12.2005- 'Norms for a Safe Transport of Radioactive Material', the IAEA Vienna Recommendation stipulated in the Safety standard TS-R-1- Regulation for the Safe Transport of Radioactive Material, 2005 Edition, and other applicable international recommendations. The paper will describe the components of the designed testing facilities, and the qualification testing to be performed for all type A, B and C packages subjected to the testing. In addition, a part of the qualification tests for a package (designed and manufactured in INR Pitesti) used for transport and storage of spent fuel LEU elements of a TRIGA nuclear reactor will be described and analyzed. Quality assurance and quality controls measures taken in order to meet technical specification provided by the design are also presented and commented. The paper concludes that the new Romanian Testing Facilities for RAM packages will comply with the national safe standards as well as with the IAEA applicable recommendation provided by the TS-R-1 safety standard. (author)

  1. On safety 1E qualification of electrical equipment for nuclear power stations

    International Nuclear Information System (INIS)

    Segarceanu, D.; Geambasu, C.; Avramescu, M.

    1995-01-01

    Electrical equipment and systems for the emergency shutdown of a nuclear reactor are qualified according to safety class 1E. Methods of qualification meeting the requirements should be used, either individually or in combination include, type-test qualification, qualification by operating experience, qualification by analysis, combined qualification. These methods qualification principles, procedures and documents are discussed. (N.T.). 1 fig

  2. Wireless installation standard

    International Nuclear Information System (INIS)

    Lim, Hwang Bin

    2007-12-01

    This is divided six parts which are radio regulation law on securing of radio resource, use of radio resource, protection of radio resource, radio regulation enforcement ordinance with securing, distribution and assignment of radio regulation, radio regulation enforcement regulation on utility of radio resource and technical qualification examination, a wireless installation regulation of technique standard and safety facility standard, radio regulation such as certification regulation of information communicative machines and regulation of radio station on compliance of signal security, radio equipment in radio station, standard frequency station and emergency communication.

  3. Perencanaan dan Implementasi Information Security Management System Menggunakan Framework ISO/IEC 20071

    Directory of Open Access Journals (Sweden)

    Anggi Anugraha Putra

    2016-01-01

    Full Text Available Penerapan tata kelola Teknologi Informasi saat ini sudah menjadi kebutuhan dan tuntutan di setiap instansi penyelenggara pelayanan publik mengingat peran TI yang semakin penting bagi upaya peningkatan kualitas layanan sebagai salah satu realisasi dari tata kelola pemerintahan yang baik (Good Corporate Governance. Dalam penyelenggaraan tata kelola TI, faktor keamanan informasi merupakan aspek yang sangat penting diperhatikan mengingat kinerja tata kelola TI akan terganggu jika informasi sebagai salah satu objek utama tata kelola TI mengalami masalah keamanan informasi yang menyangkut kerahasiaan (confidentiality, keutuhan (integrity dan ketersediaan (availability. Information Security Management System (ISMS adalah seperangkat kebijakan berkaitan dengan manajemen keamanan informasi atau terkait dengan risiko TI. Prinsip yang mengatur di balik ISMS adalah bahwa organisasi harus merancang, menerapkan dan memelihara seperangkat kebijakan, proses dan sistem untuk mengelola risiko aset informasi mereka, sehingga memastikan tingkat risiko keamanan informasi yang dapat diterima. Dari perencanaan dan implementasi sistem manajemen keamanan informasi ini, dihasilkan daftar nilai risiko akhir aset- aset kritikal dan dokumen-dokumen tata kelola penunjang ISMS. Metode penelitian yang digunakan adalah studi kasus yang didalam hal ini, merupakan penelitian kualitatif. Adapun proses yang digunakan untuk mengukur tingkat kematangan dari tata kelola keamanan sistem informasi ini berdasarkan kerangka kerja ISO/IEC 27001. Dari kerangka tersebut kemudian dilakukan evaluasi terhadap objek kontrol yang dimiliki ISO/IEC 27001. Hasil yang didapat adalah peningkatan terhadap tata kelola keamanan sistem informasi. Kesimpulan dari penelitian ini adalah dibutuhkannya tata kelola keamanan sistem informasi agar IT dapat diandalkan untuk mencapai tujuan bisnis.

  4. Comparative study on implementation of management requires from ABNT NBR ISO/IEC 17025

    International Nuclear Information System (INIS)

    Suplino Filho, Carlos Alberto Lucas; Souza, Luciane de Rezende; Oliveira, Estela Maria de

    2014-01-01

    This work was developed in order to emphasize the importance of laboratory management system in the direction and control of the company or institute with regard to the quality of delivery of ionizing radiation service to society. It was developed a comparative study of managerial points of Deming with the managerial requirements of ISO / IEC 17025, which found that the difficulties of the laboratories indicated by nonconformities tracked during audits, are related to specific points cited by Deming. (author)

  5. 7th Annual CMMI Technology Conference and User Group. Volume 1. Tuesday Presentations

    Science.gov (United States)

    2007-11-15

    and models • Harmonization of ISO /IEC 12207 (Standard for Information Technology - Software Life Cycle Processes) & ISO /IEC15288 Ø ODUSD(A&T) Systems...15288: SE-System Life Cycle Processes ISO /IEC 12207 : Standard for IT-Software life cycle processes [also Industry Implementation via IEEE/EIA] IEEE...15288 (04) INCOSE SE HB v3.1 (07) ISO /IEC 15288( 07) IEEE/EIA 12207 (97) reaffirmed@ GEIA [03] ISO /IEC 12207 (95) ISO /IEC 12207 07) SE standards

  6. Pembuatan Tata Kelola Keamanan Informasi Kontrol Akses Berbasis ISO/IEC 27001:2005 Pada Kantor Pelayanan Perbendaharaan Surabaya I

    Directory of Open Access Journals (Sweden)

    Margo Utomo

    2012-09-01

    Full Text Available Perkembangan teknologi informasi yang pesat saat ini turut berimbas kepada penggunaan teknologi informasi di lingkungan pemerintahan. KPPN Surabaya I sebagai instansi vertikal dari Direktorat Jenderal Perbendaharaan juga menerapkan teknologi informasi dalam untuk mendukung kegiatan pelayanan terhadap satuan kerja yang berada di lingkup bayarnya. Sayangnya masalah keamanan informasi yang merupakan bagian penting dari teknologi informasi sering kali kurang mendapatkan perhatian. Tidak dapat dipungkiri bahwa munculnya ancaman ataupun kelemahan dalam teknologi informasi dapat menggangu jalannya kegiatan pelayanan yang menggunakan teknologi informasi. Oleh karena itu diperlukan pengelolaan teknologi informasi berbasis risiko yang dituangkan dalam tata kelola untuk mengelola ancaman ataupun kelemahan yang muncul. ISO/IEC 27001:2005 merupakan framework sistem manajemen keamanan informasi yang dapat dijadikan dasar dalam pengelolaan keamanan informasi. Tata kelola keamanan informasi yang dibuat ini menitikberatkan pada kontrol akses yang merupakan salah satu kotrol keamanan dari ISO/IEC 27001:2005

  7. FY 1999 Report on the technical results. Research and development project for creation of the quick-effect type international standards (Standardization in the field of safety of machinery); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Kikai anzensei ni kakawaru hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    It is necessary to standardize the concepts and terminology of safety, design principles, protection and technology for evaluation of safety over a wide range including designs and specifications, in order to secure safety of the users. The international standardization has been promoted, based on the European voluntary standards EN. It is necessary for Japan to propose the international standards reflecting the industrial environments of Japan, in order to keep and expand her international competitiveness. Those technologies developed for the above purposes include the safety-related ones based on the Japanese electronic technologies, electronized operation-controlling technologies with dynamic fail safe signal processing, DC power supply circuit with a failure-sensing circuit, opto-ultrasonic hybrid type personal sensing device and pressure-sensitive mat sensor, emergency stop devices having no electrical contact to eliminate the contact fusing risk, and video camera system which facilitates emergency stop action of machinery. These results are submitted to the related technical committees of ISO or IEC. A total of 46 items of the international standard proposal drafts related to IEC/TC44 are also submitted. (NEDO)

  8. International laser safety standardization. From the European perspective with an emphasis on materials processing

    Energy Technology Data Exchange (ETDEWEB)

    Schulmeister, K [Div. of Life Sciences, Dept. of Radiation Protection, Oesterreichisches Forschungszentrum Seibersdorf, 2444 Seibersdorf (Austria)

    1997-08-01

    This report reviews international standards relevant to the safety of laser products and laser installations, with an emphasis on the safety of laser materials processing from the European perspective. In the first paragraphs an overview of the international standards organisations, their relative roles and ways of developing new standards is given. In the second part of the report, work currently underway in the respective standards committees is summarised and specific standards dealing with different aspects of laser safety are discussed. An appendix contains a list of standards organised in standards organisations (IEC, ISO and EN). (author)

  9. International laser safety standardization. From the European perspective with an emphasis on materials processing

    International Nuclear Information System (INIS)

    Schulmeister, K.

    1997-08-01

    This report reviews international standards relevant to the safety of laser products and laser installations, with an emphasis on the safety of laser materials processing from the European perspective. In the first paragraphs an overview of the international standards organisations, their relative roles and ways of developing new standards is given. In the second part of the report, work currently underway in the respective standards committees is summarised and specific standards dealing with different aspects of laser safety are discussed. An appendix contains a list of standards organised in standards organisations IEC, ISO and EN). (author)

  10. Reaction Qualifications Revisited

    DEFF Research Database (Denmark)

    Lippert-Rasmussen, Kasper

    2009-01-01

    to a person's effectiveness by causing a favourable reaction in customers, co-workers etc. (for short: recipients) - are involved, this assumption is false. Building on work by Wertheimer, Mason, and Miller, this paper proposes an account of the reaction qualifications that count, from the point of view...... preferences, recipients should not respond to the applicant actually hired on the basis of their (the recipients') racial preferences. My account decomposes the meritocratic ideal into four separate norms, one of which applies to recipients rather than to selectors. Finally, it defends the view that reaction...... qualifications based on antimeritocratic reactions, while not unproblematic, are not entirely irrelevant from the point of view of merit. Notably, selectors need not discount them when no one - including the targets of the objectionable preferences - is unfairly disadvantaged. Because not all problematic...

  11. QUALIFICATIONS FRAMEWORKS FOR LIFELONG LEARNING CONQUERING THE WORLD?

    Directory of Open Access Journals (Sweden)

    Arjen Deij

    2014-01-01

    Full Text Available The paper reveals the international prospects of developing and spreading the qualifications frameworks across the globe. It introduces the key terms and concepts related to the given issue, and examines both the benefits and challenges of qualifications frameworks implementation. The author looks into the origins and causes of the worldwide interest in qualifications framework application, and gives the overview of related recent publications and their conclusions to reinforce the provided argumentation.

  12. LTP fibre injector qualification and status

    International Nuclear Information System (INIS)

    Bogenstahl, J; Cunningham, L; Fitzsimons, E D; Hough, J; Killow, C J; Perreur-Lloyd, M; Robertson, D; Rowan, S; Ward, H

    2009-01-01

    This paper presents the current state of the LISA Technology Package (LTP) fibre injector qualification project in terms of vibration and shock tests. The fibre injector is a custom built part and therefore must undergo a full space qualification process. The mounting structure and method for sinusoidal vibration and random vibration tests as well as shock tests will be presented. Furthermore a proposal will be presented to use the fibre injector pair qualification model to build an optical prototype bench. The optical prototype bench is a full-scale model of the flight model. It will be used for development and rehearsal of all the assembly stages of the flight model and will provide an on-ground simulator for investigation as an updated engineering model.

  13. Qualification of high density aluminide fuels for the BR2 reactor

    International Nuclear Information System (INIS)

    Beeckmans de West-Meerbeeck, Andre; Gubel, Pol; Ponsard, Bernard; Pin, Thomas; Falgoux, Jean Louis

    2005-01-01

    The BR2 operation still relies on the use of 90..93% enriched HEU aluminide fuel. The availability of a limited batch of 73% enriched HEU from reprocessed BR2 uranium in Dounreay justified 10 years ago the qualification and use of this material. After some preliminary test irradiations, various batches of fuel elements were fabricated by the UKAEA-Dounreay and successfully irradiated. Due to their lower 235 U content (0.050 g 235 U/cm 2 ), these elements were always irradiated together with standard 90...93% HEU fuel elements. A mixed-core strategy was developed at this occasion for an optimal utilization, and was reported during the 4th RRFM conference (March 19-21, 2000, Colmar, France). The availability of a new batch of fresh 73% HEU material was the occasion, a few years ago, to initiate the development, fabrication and qualification of a new high density fuel element. An order was placed with CERCA to assess the optimal fabrication methods and tooling required to meet as far as possible the existing BR2 standard specifications and 235 U content (0.060 g 235 U/cm 2 ). This development phase has been already reported during the 7th RRFM conference (March 9-12, 2003, Aix-en-Provence, France). Afterwards, six lead test fuel elements were ordered for qualification by irradiation. The neutronic properties of the fuel elements were adjusted and optimized. After a short summary of the main results of the development program, this paper describes the nuclear characteristics of the high density fuel elements and comments on the nuclear follow-up of the lead test fuel elements during their irradiation for five cycles in the BR2 reactor and the return of experience for CERCA. (author)

  14. Qualification of software and hardware

    International Nuclear Information System (INIS)

    Gossner, S.; Schueller, H.; Gloee, G.

    1987-01-01

    The qualification of on-line process control equipment is subdivided into three areas: 1) materials and structural elements; 2) on-line process-control components and devices; 3) electrical systems (reactor protection and confinement system). Microprocessor-aided process-control equipment are difficult to verify for failure-free function owing to the complexity of the functional structures of the hardware and to the variety of the software feasible for microprocessors. Hence, qualification will make great demands on the inspecting expert. (DG) [de

  15. Background information for NDT qualification of Finnish disposal canisters of spent fuel

    International Nuclear Information System (INIS)

    Sarkimo, M.; Pitkaenen, J.

    2013-12-01

    This report presents a review to basic concepts, which are applied in the qualification of non-destructive testing (NDT) techniques. The qualification systems developed and used in some countries are briefly described in the beginning of the report. Anyway the report mainly discusses the qualification practices applied in the Finnish nuclear industry. The Finnish Radiation and Nuclear Safety Authority (STUK) in the YVL Guide 3.8 define the Finnish qualification approach applied for the in-service inspections. The principles presented in this document follow the views of the international organisations: Nuclear Regulator Working Group (NRWG) and European Network for Inspection and Qualification (ENIQ). For the practical qualification work a national guideline is established using so called SP-documents that include specific rules and instructions for execution of qualifications in accordance with YVL Guide 3.8 principles. Altogether the Finnish qualification system can be seen very well to follow the European (ENIQ) methodology. The report discusses several qualification terms and documents. Thus the normally necessary tasks and parts of a qualification are described. The qualification can be seen as a project that includes several tasks, which will be performed by different parties. Enough resources and time should be reserved for the planning and control of a qualification project to ensure its fluent progress. Some tasks are discussed in the report taking into account the situation in the qualification cases that are seen to be linked to the inspections of disposal canisters of spent fuel. (orig.)

  16. Background information for NDT qualification of Finnish disposal canisters of spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sarkimo, M. [VTT Technical Research Centre of Finland, Espoo (Finland); Pitkaenen, J.

    2013-12-15

    This report presents a review to basic concepts, which are applied in the qualification of non-destructive testing (NDT) techniques. The qualification systems developed and used in some countries are briefly described in the beginning of the report. Anyway the report mainly discusses the qualification practices applied in the Finnish nuclear industry. The Finnish Radiation and Nuclear Safety Authority (STUK) in the YVL Guide 3.8 define the Finnish qualification approach applied for the in-service inspections. The principles presented in this document follow the views of the international organisations: Nuclear Regulator Working Group (NRWG) and European Network for Inspection and Qualification (ENIQ). For the practical qualification work a national guideline is established using so called SP-documents that include specific rules and instructions for execution of qualifications in accordance with YVL Guide 3.8 principles. Altogether the Finnish qualification system can be seen very well to follow the European (ENIQ) methodology. The report discusses several qualification terms and documents. Thus the normally necessary tasks and parts of a qualification are described. The qualification can be seen as a project that includes several tasks, which will be performed by different parties. Enough resources and time should be reserved for the planning and control of a qualification project to ensure its fluent progress. Some tasks are discussed in the report taking into account the situation in the qualification cases that are seen to be linked to the inspections of disposal canisters of spent fuel. (orig.)

  17. 48 CFR 1437.7001 - Contractor qualification requirements.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contractor qualification requirements. 1437.7001 Section 1437.7001 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... Contractor qualification requirements. (a) Prior to award of a contract for real property appraisal services...

  18. Supplement to nuclear EQ sourcebook: A compilation of documents for nuclear equipment qualification

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    In the nuclear power industry, environmental and seismic qualification of safety-related electrical and instrumentation equipment is collectively known as Equipment Qualification (EQ). Related technology, as well as regulatory requirements, have evolved rapidly during the last 15 years. For environmental qualification, what began in 1971 with one trial-use guide (IEEE Std 323-1971), now stands as a full complement of Nuclear Regulatory Commission (NRC) rules, guides, and industry standards. As the original 1992 version of the Nuclear EQ Sourcebook was compiled to serve the user-community need for a complete and exhaustive single source of nuclear EQ documentation, this Supplement is published to provide the user community with nuclear EQ documentation revisions and updates that have been published since the publication of the original volume in May of 1992. The first volume of this publication included documents issued before December, 1991. That first volume was well received and also prompted positive response from industry on its usefulness and on recommendations to improve the completeness and enhance the ease of use. This Supplement, therefore, includes new documents, revisions, and updates issued and published since December 1991 and up to and including March 1993. It incorporates various enhancements in order to better serve the user community. One such enhancement included in this Supplement is the new Equipment Classification Index that is described in the User Guide section of this publication. 37 papers, including Bulletins, Federal rules, Generic Letters, Notices, Regulatory Guides, IEEE Standards, IEEE Recommended Practices, and IEEE Guides, have been processed separately for inclusion on the data base

  19. NC ISO/IEC1725:00 Accreditation process of CPHR main laboratories

    International Nuclear Information System (INIS)

    Marrero Garcia, Mariela; Molina perez, Daniel; Fernandez Gomez, Maria; Walwyn Salas, Gonzalo

    2003-01-01

    With the objective of offering technically qualified and competitive services one works in our laboratories under the requirements of a System of the Quality from 1993. In 1999 that was already with a draft of the new model ISO/IEC 17025:00 the steps they were given for the change of the Guide 25. At the moment with 3 laboratories accredited by the Cuban organ (ONARC), we are pioneer in these changes because alone a very reduced group of laboratories in the country has achieved it. The present work enunciates the antecedents of the change, the main non conformities during the evaluations for the accreditation and the obtained results

  20. Europeans come together on qualification

    International Nuclear Information System (INIS)

    Whittle, J.

    1996-01-01

    Utilities operating nuclear power plants in Europe have formed the European Network for Inspection Qualification (ENIQ) to produce a common approach to demonstrating that non-destructive testing is capable providing the information to ensure the absence of significant defects in nuclear plants. Major developments over recent months have included the issue by ENIQ of a formal document defining the methodology for the conduct of qualification which sets out the principles that detailed systems, within an individual country context, should embody. A pilot study on pipe welds typical of those in BWR recirculation loops is being conducted to explore the issues involved in the practical application of the methodology. In parallel with ENIQ, the European Nuclear Regulators Working Group has set up a Task Force in an attempt to define a common regulatory position on non-destructive testing qualifications and has produced its own document which is wider in scope than that of ENIQ. (UK)

  1. Recruitment, qualification and training of personnel for nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    The objective of this Safety Guide is to outline the various factors that should to be considered in order to ensure that the operating organization has a sufficient number of qualified personnel for safe operation of a nuclear power plant. In particular, the objective of this publication is to provide general recommendations on the recruitment and selection of plant personnel and on the training and qualification practices that have been adopted in the nuclear industry since the predecessor Safety Guide was published in 1991. In addition, this Safety Guide seeks to establish a framework for ensuring that all managers and staff employed at a nuclear power plant demonstrate their commitment to the management of safety to high professional standards. This Safety Guide deals specifically with those aspects of qualification and training that are important to the safe operation of nuclear power plants. It provides recommendations on the recruitment, selection, qualification, training and authorization of plant personnel. That is, of all personnel in all safety related functions and at all levels of the plant. Some parts or all of this Safety Guide may also be used, with due adaptation, as a guide to the recruitment, selection, training and qualification of staff for other nuclear installations (such as research reactors or nuclear fuel cycle facilities). Section 2 gives guidance on the recruitment and selection of suitable personnel for a nuclear power plant. Section 3 gives guidance on the establishment of personnel qualification, explains the relationship between qualification and competence, and identifies how competence may be developed through education, experience and training. Section 4 deals with general aspects of the training policy for nuclear power plant personnel: the systematic approach, training settings and methods, initial and continuing training, and the keeping of training records. Section 5 provides guidance on the main aspects of training programmes

  2. Recruitment, qualification and training of personnel for nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2002-01-01

    The objective of this Safety Guide is to outline the various factors that should to be considered in order to ensure that the operating organization has a sufficient number of qualified personnel for safe operation of a nuclear power plant. In particular, the objective of this publication is to provide general recommendations on the recruitment and selection of plant personnel and on the training and qualification practices that have been adopted in the nuclear industry since the predecessor Safety Guide was published in 1991. In addition, this Safety Guide seeks to establish a framework for ensuring that all managers and staff employed at a nuclear power plant demonstrate their commitment to the management of safety to high professional standards. This Safety Guide deals specifically with those aspects of qualification and training that are important to the safe operation of nuclear power plants. It provides recommendations on the recruitment, selection, qualification, training and authorization of plant personnel; that is, of all personnel in all safety related functions and at all levels of the plant. Some parts or all of this Safety Guide may also be used, with due adaptation, as a guide to the recruitment, selection, training and qualification of staff for other nuclear installations (such as research reactors or nuclear fuel cycle facilities). Section 2 gives guidance on the recruitment and selection of suitable personnel for a nuclear power plant. Section 3 gives guidance on the establishment of personnel qualification, explains the relationship between qualification and competence, and identifies how competence may be developed through education, experience and training. Section 4 deals with general aspects of the training policy for nuclear power plant personnel: the systematic approach, training settings and methods, initial and continuing training, and the keeping of training records. Section 5 provides guidance on the main aspects of training programmes

  3. Strategy for Qualification of the Plutonium Immobilized Form

    International Nuclear Information System (INIS)

    Marra, J.C.; Marra, S.L.; Bibler, N.E.; Strachan, D.M.; Shaw, H.F.

    1998-01-01

    In order to dispose of a radioactive waste form in a federal high- level waste repository, a waste form qualification strategy and program must be developed. The waste form qualification program must include the acceptance specifications for the product, show how compliance with these specifications will be met, and then demonstrate compliance. An important element of this program is developing a measure to demonstrate product consistency. For the can- in-canister option, waste form qualification is needed not only for the Pu immobilized form but also for the high-level waste glass canister containing the Pu waste form. The latter will require close interaction and coordination with the U.S. Department of Energy - Office of Environmental Management (DOE-EM) who, through their contractor at the Savannah River Site (SRS), is the producer of the high-level waste form at the Defense Waste Processing Facility (DWPF). In this paper a waste form qualification strategy for the plutonium ceramic form is described that utilizes, as much as possible, the qualification strategy successfully used for vitrified high-level waste

  4. Characterization of an active dosemeter according to IEC 61526:2010

    International Nuclear Information System (INIS)

    Cardoso, J.; Santos, L.; Santos, J.A.M.; Alves, J.G.; Oliveira, C.

    2016-01-01

    The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer. (authors)

  5. 49 CFR 214.349 - Training and qualification of watchmen/lookouts.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Training and qualification of watchmen/lookouts...) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection § 214.349 Training and qualification of watchmen/lookouts. (a) The training and qualification for...

  6. SRS H1616 Hydride Transport Vessel Qualification Report

    International Nuclear Information System (INIS)

    Smith, A.C.

    1999-01-01

    This report serves as the design qualification basis for both transport and facility use. Headings identify report sections as containing qualification information for transport use, facility use, or both transport and facility use

  7. SRS H1616 Hydride Transport Vessel Qualification Report

    International Nuclear Information System (INIS)

    Van Alstine, M.N.

    1998-01-01

    This report serves as the design qualification basis for both transport and facility use. Headings identify report sections as containing qualification information for transport use, facility use, or both transport and facility use

  8. 76 FR 82306 - Draft Guidance for Industry on Use of Histology in Biomarker Qualification Studies; Availability

    Science.gov (United States)

    2011-12-30

    ...] Draft Guidance for Industry on Use of Histology in Biomarker Qualification Studies; Availability AGENCY... announcing the availability of a draft guidance for industry entitled ``Use of Histology in Biomarker... studies for which histology is a reference standard. This guidance discusses the processes that should be...

  9. Integrated Information System for Higher Education Qualifications

    Directory of Open Access Journals (Sweden)

    Catalin Ionut SILVESTRU

    2012-10-01

    Full Text Available In the present article we aim to study thoroughly and detail aspects related to architectures specific for e-learning and management of human resources training interconnected to management of qualifications. In addition, we take into consideration combining e-learning architectures with software in an e-learning system interconnected with the National Registry of Qualifications of Higher Education, in view of developing and information system that correlates educational supply from higher education from Romania with labor market demands through qualifications. The scientific endeavor consists of original architectural solutions to integrate data, systems, processes, services from various sources and to use them in the proposed system. The practical result of the scientific endeavor is represented by design of architectures required for developing an e-learning system interconnected with the National Registry of Qualifications from Romania, which involve in first stage the qualifications provided by higher education. The proposed innovative solution consists in the fact that the proposed information system combines the advantages of content management system (CMS with learning content management system (LCMS and with reusable learning objects (RLO. Thus, the architecture proposed in the research ensures the integration of a content management system with a portal for information, guidance and support in making a professional project. The integration enables correlation of competences with content areas and specific items from various teaching subjects, thus evaluating the usefulness for this registry from learning/educational perspective. Using the proposed information system in enables correlation among qualifications, content of educational program and continuous self-evaluation opportunities, which facilitate monitoring of progress and adjustment of learning content.

  10. Developing competence based qualification system in the nuclear energy sector

    International Nuclear Information System (INIS)

    Ceclan, Mihail

    2016-01-01

    The Institute for Energy and Transport of the Joint Research Centre, European Commission, developed a strategy and road map for ECVET implementation. The JRC road map for European Credit System for Vocational Education and Training (ECVET) implementation has reached the stage of Competence-Based Qualification System development. The Competence-Based Qualification System can help bridge the gap between Human Resources demand and supply in the nuclear market by structuring qualifications in small independent parts. This very specific ECVET feature of a qualification, facilitates the process of competences accumulation and the lifelong learning, mobility and flexible learning pathways. New developments are presented about the Competence-Based Qualification System development for the nuclear energy sector.

  11. Developing competence based qualification system in the nuclear energy sector

    Energy Technology Data Exchange (ETDEWEB)

    Ceclan, Mihail [European Commission, Petten (Netherlands). Inst. for Energy and Transport

    2016-04-15

    The Institute for Energy and Transport of the Joint Research Centre, European Commission, developed a strategy and road map for ECVET implementation. The JRC road map for European Credit System for Vocational Education and Training (ECVET) implementation has reached the stage of Competence-Based Qualification System development. The Competence-Based Qualification System can help bridge the gap between Human Resources demand and supply in the nuclear market by structuring qualifications in small independent parts. This very specific ECVET feature of a qualification, facilitates the process of competences accumulation and the lifelong learning, mobility and flexible learning pathways. New developments are presented about the Competence-Based Qualification System development for the nuclear energy sector.

  12. The use of case tools in OPG safety analysis code qualification

    International Nuclear Information System (INIS)

    Pascoe, J.; Cheung, A.; Westbye, C.

    2001-01-01

    Ontario Power Generation (OPG) is currently qualifying its critical safety analysis software. The software quality assurance (SQA) framework is described. Given the legacy nature of much of the safety analysis software the reverse engineering methodology has been adopted. The safety analysis suite of codes was developed over a period of many years to differing standards of quality and had sparse or incomplete documentation. Key elements of the reverse engineering process require recovery of design information from existing coding. This recovery, if performed manually, could represent an enormous effort. Driven by a need to maximize productivity and enhance the repeatability and objectivity of software qualification activities the decision was made to acquire or develop and implement Computer Aided Software Engineering (CASE) tools. This paper presents relevant background information on CASE tools and discusses how the OPG SQA requirements were used to assess the suitability of available CASE tools. Key findings from the application of CASE tools to the qualification of the OPG safety analysis software are discussed. (author)

  13. Software validation applied to spreadsheets used in laboratories working under ISO/IEC 17025

    Science.gov (United States)

    Banegas, J. M.; Orué, M. W.

    2016-07-01

    Several documents deal with software validation. Nevertheless, more are too complex to be applied to validate spreadsheets - surely the most used software in laboratories working under ISO/IEC 17025. The method proposed in this work is intended to be directly applied to validate spreadsheets. It includes a systematic way to document requirements, operational aspects regarding to validation, and a simple method to keep records of validation results and modifications history. This method is actually being used in an accredited calibration laboratory, showing to be practical and efficient.

  14. A system for personnel qualification of non-destructive testing procedures from testing and and qualification system in Sweden

    International Nuclear Information System (INIS)

    Kuna, M.; Kubis, S.; Plasek, J.

    1999-01-01

    The method for qualification of non-destructive testing personnel carrying out inspections by means of ultrasonic and eddy-current tests to inspect cladding in BWR reactor pressure vessel and core shroud lid. Development of procedures tests with real artificial cracks, blind tests. Evaluation of results by the Swedish Qualification Commission. Performance of the tests at Oskarshamn-1

  15. Energy Efficiency Standards of Induction Motors, ¿Are you Prepared Latin America?

    Directory of Open Access Journals (Sweden)

    Carlos M. Londoño-Parra

    2013-06-01

    Full Text Available In Colombia the regulatory process regarding the energy efficiency of end-use prod-ucts is emerging with the draft technical regulation product labeling RETIQ, which includes in Annex E, the test methods for determining the efficiency of motors alternat-ing current induction. The goal of this paper is to compare the energy efficiency of induction motors between the countries of Latin America and the countries of the major economies of the globe, considering four aspects: the current state of classification standards and test procedures of induction motors efficiency, multilateral agreements of mutual recognition, the infrastructure to conduct tests of the standard and support programs to improve the efficiency of electric motor-driven systems. The study reveals that Latin America is a considerable delay in the implementation of classification standards and methods for testing the efficiency of electric motors, most widely used in the world: IEC 60034-30:2008, IEC 60034-2-1: 2007 IEEE 112:2004 and EPAct'92, with respect to the countries of the European Union, United States, China, Australia, and other developed countries, in which these standards have been adopted. Furthermore, the region is evident in the absence of programs focused on improving the energy efficiency of electric motors and a limited number of accredited laboratories to evaluate their efficiency, which leads to most Latin American countries to establish agreements mutual recognition for this purpose.

  16. Energy Efficiency Standards of Induction Motors, ¿Are you Prepared Latin America?

    Directory of Open Access Journals (Sweden)

    Carlos M. Londoño-Parra

    2013-06-01

    Full Text Available In Colombia the regulatory process regarding the energy efficiency of end-use products is emerging with the draft technical regulation product labeling RETIQ, which includes in Annex E, the test methods for determining the efficiency of motors alternating current induction. The goal of this paper is to compare the energy efficiency of induction motors between the countries of Latin America and the countries of the major economies of the globe, considering four aspects: the current state of classification standards and test procedures of induction motors efficiency, multilateral agreements of mutual recognition, the infrastructure to conduct tests of the standard and support programs to improve the efficiency of electric motor-driven systems. The study reveals that Latin America is a considerable delay in the implementation of classification standards and methods for testing the efficiency of electric motors, most widely used in the world: IEC 60034-30:2008, IEC 60034-2-1: 2007 IEEE 112:2004 and EPAct'92, with respect to the countries of the European Union, United States, China, Australia, and other developed countries, in which these standards have been adopted. Furthermore, the region is evident in the absence of programs focused on improving the energy efficiency of electric motors and a limited number of accredited laboratories to evaluate their efficiency, which leads to most Latin American countries to establish agreements mutual recognition for this purpose.

  17. EASIER ACCESS TO STANDARDS DOCUMENTATION

    CERN Multimedia

    2001-01-01

    Many organizations issuing standards offer reduced prices for publications to their members. Paying a membership fee, even a site membership fee, can therefore be worthwhile - even if relatively few standards are needed. The Library is now exploring the possibility, in collaboration with the rest of the CERN community, of joining standards-issuing organizations. So why not share your costs with the rest of the organization wherever this can be done without violating copyright or access regulations? The Library now provides documentation and other member services from IPC, the Association Connecting Electronics Industries (http://www.ipc.org/html/fsabout.htm) at favourable prices for the entire CERN population. For more information, or if you are a member of any other organization which provides services which could be shared CERN-wide, please contact library.desk@cern.ch . We remind all users of international standards, that CERN has special agreements with ISO and IEC (see Bulletin 50/2000). You can order st...

  18. 10 CFR 50.76 - Licensee's change of status; financial qualifications.

    Science.gov (United States)

    2010-01-01

    ... the financial qualifications information that would be required for obtaining an initial operating license as specified in § 50.33(f)(2). The financial qualifications information must address the first... 10 Energy 1 2010-01-01 2010-01-01 false Licensee's change of status; financial qualifications. 50...

  19. DNA Qualification Workflow for Next Generation Sequencing of Histopathological Samples

    Science.gov (United States)

    Simbolo, Michele; Gottardi, Marisa; Corbo, Vincenzo; Fassan, Matteo; Mafficini, Andrea; Malpeli, Giorgio; Lawlor, Rita T.; Scarpa, Aldo

    2013-01-01

    Histopathological samples are a treasure-trove of DNA for clinical research. However, the quality of DNA can vary depending on the source or extraction method applied. Thus a standardized and cost-effective workflow for the qualification of DNA preparations is essential to guarantee interlaboratory reproducible results. The qualification process consists of the quantification of double strand DNA (dsDNA) and the assessment of its suitability for downstream applications, such as high-throughput next-generation sequencing. We tested the two most frequently used instrumentations to define their role in this process: NanoDrop, based on UV spectroscopy, and Qubit 2.0, which uses fluorochromes specifically binding dsDNA. Quantitative PCR (qPCR) was used as the reference technique as it simultaneously assesses DNA concentration and suitability for PCR amplification. We used 17 genomic DNAs from 6 fresh-frozen (FF) tissues, 6 formalin-fixed paraffin-embedded (FFPE) tissues, 3 cell lines, and 2 commercial preparations. Intra- and inter-operator variability was negligible, and intra-methodology variability was minimal, while consistent inter-methodology divergences were observed. In fact, NanoDrop measured DNA concentrations higher than Qubit and its consistency with dsDNA quantification by qPCR was limited to high molecular weight DNA from FF samples and cell lines, where total DNA and dsDNA quantity virtually coincide. In partially degraded DNA from FFPE samples, only Qubit proved highly reproducible and consistent with qPCR measurements. Multiplex PCR amplifying 191 regions of 46 cancer-related genes was designated the downstream application, using 40 ng dsDNA from FFPE samples calculated by Qubit. All but one sample produced amplicon libraries suitable for next-generation sequencing. NanoDrop UV-spectrum verified contamination of the unsuccessful sample. In conclusion, as qPCR has high costs and is labor intensive, an alternative effective standard workflow for

  20. DNA qualification workflow for next generation sequencing of histopathological samples.

    Directory of Open Access Journals (Sweden)

    Michele Simbolo

    Full Text Available Histopathological samples are a treasure-trove of DNA for clinical research. However, the quality of DNA can vary depending on the source or extraction method applied. Thus a standardized and cost-effective workflow for the qualification of DNA preparations is essential to guarantee interlaboratory reproducible results. The qualification process consists of the quantification of double strand DNA (dsDNA and the assessment of its suitability for downstream applications, such as high-throughput next-generation sequencing. We tested the two most frequently used instrumentations to define their role in this process: NanoDrop, based on UV spectroscopy, and Qubit 2.0, which uses fluorochromes specifically binding dsDNA. Quantitative PCR (qPCR was used as the reference technique as it simultaneously assesses DNA concentration and suitability for PCR amplification. We used 17 genomic DNAs from 6 fresh-frozen (FF tissues, 6 formalin-fixed paraffin-embedded (FFPE tissues, 3 cell lines, and 2 commercial preparations. Intra- and inter-operator variability was negligible, and intra-methodology variability was minimal, while consistent inter-methodology divergences were observed. In fact, NanoDrop measured DNA concentrations higher than Qubit and its consistency with dsDNA quantification by qPCR was limited to high molecular weight DNA from FF samples and cell lines, where total DNA and dsDNA quantity virtually coincide. In partially degraded DNA from FFPE samples, only Qubit proved highly reproducible and consistent with qPCR measurements. Multiplex PCR amplifying 191 regions of 46 cancer-related genes was designated the downstream application, using 40 ng dsDNA from FFPE samples calculated by Qubit. All but one sample produced amplicon libraries suitable for next-generation sequencing. NanoDrop UV-spectrum verified contamination of the unsuccessful sample. In conclusion, as qPCR has high costs and is labor intensive, an alternative effective standard

  1. Test report: Electron-proton spectrometer qualification test unit, qualification test

    Science.gov (United States)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  2. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  3. A methodology for distinguishing divergent cell fates within a common progenitor population: adenoma- and neuroendocrine-like cells are confounders of rat ileal epithelial cell (IEC-18 culture

    Directory of Open Access Journals (Sweden)

    Paxton Jessica B

    2005-01-01

    Full Text Available Abstract Background IEC-18 cells are a non-transformed, immortal cell line derived from juvenile rat ileal crypt cells. They may have experimental advantages over tumor-derived gastrointestinal lineages, including preservation of phenotype, normal endocrine responses and retention of differentiation potential. However, their proclivity for spontaneous differentiation / transformation may be stereotypical and could represent a more profound experimental confounder than previously realized. We hypothesized that IEC-18 cells spontaneously diverge towards a uniform mixture of epigenetic fates, with corresponding phenotypes, rather than persist as a single progenitor lineage. Results IEC-18 cells were cultured for 72 hours in serum free media (SFM, with and without various insulin-like growth factor agonists to differentially boost the basal rate of proliferation. A strategy was employed to identify constitutive genes as markers of divergent fates through gene array analysis by cross-referencing fold-change trends for individual genes against crypt cell abundance in each treatment. We then confirmed the cell-specific phenotype by immunolocalization of proteins corresponding to those genes. The majority of IEC-18 cells in SFM alone had a loss in expression of the adenomatous polyposis coli (APC gene at the mRNA and protein levels, consistent with adenoma-like transformation. In addition, a small subset of cells expressed the serotonin receptor 2A gene and had neuroendocrine-like morphology. Conclusions IEC-18 cells commonly undergo a change in cell fate prior to reaching confluence. The most common fate switch that we were able to detect correlates with a down regulation of the APC gene and transformation into an adenoma-like phenotype.

  4. AGR-1 Data Qualification Interim Report

    International Nuclear Information System (INIS)

    Abbott, Machael

    2009-01-01

    Projects for the very-high-temperature reactor (VHTR) program provide data in support of Nuclear Regulatory Commission licensing of the VHTR. Fuel and materials to be used in the reactor are tested and characterized to quantify performance in high temperature and high fluence environments. The VHTR Program has established the NGNP Data Management and Analysis System (NDMAS) to ensure that VHTR data are (1) qualified for use, (2) stored in a readily accessible electronic form, and (3) analyzed to extract useful results. This document focuses on the first NDMAS objective. It describes the data streams associated with the first Advanced Gas Reactor (AGR-1) experiment, the processing of these data within NDMAS, and reports the interim FY09 qualification status of the AGR-1 data to date. Data qualification activities within NDMAS for specific types of data are determined by the data qualification category, which is assigned by the data generator, and include: (1) capture testing, to confirm that the data stored within NDMAS are identical to the raw data supplied, (2) accuracy testing, to confirm that the data are an accurate representation of the system or object being measured, and (3) documentation that the data were collected under an NQA-1 or equivalent QA program. The interim qualification status of the following four data streams is reported in this document: (1) fuel fabrication data, (2) fuel irradiation data, (3) fission product monitoring system (FPMS) data, and (4) Advanced Test Reactor (ATR) operating conditions data. A final report giving the NDMAS qualification status of all AGR-1 data (including cycle 145A) is planned for February 2010

  5. Network Authentication Protocol Studies

    Science.gov (United States)

    2009-04-01

    usually require compliance with development standards such as ISO 12207 or IEEE / IEC 12207 . Those standards mandate traceability as a property of a...standards have been proposed to deal with non-repudiation. ISO /IEC 10181-4 [19] and ISO /IEC 13888 [20, 22, 21]. While ISO /IEC 10181-4 provides a...framework for developing and employing these services, ISO /IEC 13888 consists of three parts. They propose a general model of non-repudiation and a set of

  6. Inspection procedure and essential parameters in NDT qualification

    International Nuclear Information System (INIS)

    Sarkimo, M.

    2000-06-01

    The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the mechanised ultrasonic testing. The later report explains the parameters formulated to analyse in the technical justification all aspects of the inspection application. (orig.)

  7. Space qualification of high capacity grooved heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M; Mullender, B; Druart, J [SABCA, Societe Anomyme Belgel de Construction Aeronautique (Belgium); Supper, W; Beddows, A [ESTEC-The (Netherlands)

    1997-12-31

    Based on the thermal requirements of the future telecommunication satellites, the development of a High Capacity Grooved Heat Pipe (HPG), was contracted by ESA to SABCA leading to an aluminium extruded heat pipe (outer diameter of 25 mm) based on a multi re-entrant grooves design. After an intensive acceptance test campaign whose results showed a good confidence in the design and the fulfillment of the required specifications of heat transport and on tilt capability (experimental maximum heat transport capability of 1500 Watt metres for a vapour temperature of 20 deg C), similar heat pipes have been developed with various outer diameters (11 mm, 15 mm and 20 mm) and with various shapes (circular outer shapes, integrated saddles). Several of these heat pipes were tested during two parabolic flight campaigns, by varying the heat loads during the micro-gravity periods. This HGP heat pipe family is now being submitted to a space qualification program according to ESA standards (ESA PSS-49), both in straight and bent configuration. Within this qualification, the heat pipes are submitted to an extended test campaign including environmental (random/sinus vibration, constant acceleration) and thermal tests (thermal performance, thermal cycle, thermal soak, ageing). (authors) 9 refs.

  8. Space qualification of high capacity grooved heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.; Mullender, B.; Druart, J. [SABCA, Societe Anomyme Belgel de Construction Aeronautique (Belgium); Supper, W.; Beddows, A. [ESTEC-The (Netherlands)

    1996-12-31

    Based on the thermal requirements of the future telecommunication satellites, the development of a High Capacity Grooved Heat Pipe (HPG), was contracted by ESA to SABCA leading to an aluminium extruded heat pipe (outer diameter of 25 mm) based on a multi re-entrant grooves design. After an intensive acceptance test campaign whose results showed a good confidence in the design and the fulfillment of the required specifications of heat transport and on tilt capability (experimental maximum heat transport capability of 1500 Watt metres for a vapour temperature of 20 deg C), similar heat pipes have been developed with various outer diameters (11 mm, 15 mm and 20 mm) and with various shapes (circular outer shapes, integrated saddles). Several of these heat pipes were tested during two parabolic flight campaigns, by varying the heat loads during the micro-gravity periods. This HGP heat pipe family is now being submitted to a space qualification program according to ESA standards (ESA PSS-49), both in straight and bent configuration. Within this qualification, the heat pipes are submitted to an extended test campaign including environmental (random/sinus vibration, constant acceleration) and thermal tests (thermal performance, thermal cycle, thermal soak, ageing). (authors) 9 refs.

  9. 75 FR 81789 - Third Party Testing for Certain Children's Products; Full-Size Baby Cribs and Non-Full-Size Baby...

    Science.gov (United States)

    2010-12-28

    ... Standardization (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing...

  10. Zero-correlation linear cryptanalysis with FFT and improved attacks on ISO standards Camellia and CLEFIA

    DEFF Research Database (Denmark)

    Bogdanov, Andrey; Geng, Huizheng; Wang, Meiqin

    2014-01-01

    as published in FSE'12 and ASIACRYPT'12, respectively. In this paper, we use the FFT (Fast Fourier Transform) technique to speed up the zero-correlation cryptanalysis. First, this allows us to improve upon the state-of-the-art cryptanalysis for the ISO/IEC standard and CRYPTREC-portfolio cipher Camellia...

  11. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization of methods for testing and evaluating plastic optical fiber; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Plastic hikari fiber no shiken hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Studies were made about methods for testing and evaluating plastic optical fiber (POF) for the purpose of submitting a proposition to IEC (International Electrotechnical Commission) for the methods to be internationally standardized. In this fiscal year, tests and analyses were conducted relative to the effects of the light source emission area size, wavelength, and axial displacement. Next, underfilled launch was studied from a practical viewpoint, and a method using a mode filter was proposed. Finally, round robin tests were conducted for each of the companies using overfilled launch and underfilled launch, and the reproducibility of measured values was grasped. In this fiscal year, a new study added, which involved a method for measuring structural parameters. Though POF was below standard as an object of IEC's gray scale method, yet it was found, thanks to the recently developed CCD (charge coupled device) cameras, that the method might also be applicable to POF. A groundwork plan was drafted on band test methods including the overfilled launch method toward international standardization. (NEDO)

  12. Functional Suitability Measurement using Goal-Oriented Approach based on ISO/IEC 25010 for Academics Information System

    Directory of Open Access Journals (Sweden)

    Ajeng Savitri Puspaningrum

    2017-10-01

    Full Text Available Rapid of information technology development grow a new competitive environment. Including higher education, they need to improve their service quality in order to provide education service in more competitive. One of the ways of using information technology in higher education is the used of Academic Information System (AIS. AIS was developed to achieve the goals of the learning process which is one of vision and mission organization success factor. The measurement is needed to evaluate the quality of AIS. Functionality is one of the quality factors which is measured by observing the correlation between function and functional suitability. In this study, the quality of AIS functional suitability is measured using goal-oriented approach base on ISO/IEC 25010 in the perspective of a lecturer. The strategic plan of an institution is used as a reference to measure if the system used to have meet institution goals when using this approach. The result shows that the measurement using goal-oriented approach become more objective and suitable to the need of used AIS quality improvement for the institution than the measurement with ISO/IEC 25010 only.

  13. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia Fiorini da

    2016-01-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  14. DATA QUALIFICATION REPORT: MAJOR ION AND PH DATA FOR USE ON THE YUCCA MOUNTAIN PROJECT

    International Nuclear Information System (INIS)

    C. WILSON; D.M. JENKINS; T. STEINBORN; R. WEMHEUER

    2000-01-01

    This data qualification report uses technical assessment and corroborating data methods according to Attachment 2 of AP-SIII.2Q, Rev. 0, ICN 2, ''Qualification of Unqualified Data and the Documentation of Rationale for Accepted Data'', to qualify major ion and pH data. This report was prepared in accordance with Data Qualification Plan TDP-NBS-GS-00003 1, Revision 2. Additional reports will be prepared to address isotopic and precipitation-related data. Most of the data considered in this report were acquired and developed by the U.S. Geological Survey (USGS). The data qualification team considers the sampling and analytical protocols employed by the USGS over the time period of data acquisition to be state-of-the-art. The sample collection methodologies have evolved with no significant change that could affect the quality of the data considered in this report into the currently used Hydrologic Procedures that support the Yucca Mountain Project-approved USGS Quality Assurance Program Plan. Consequently, for USGS data, the data collection methods, documentation, and results are reasonable and appropriate in view of standard practice at the time the data were collected. A small number of data sets were collected by organizations other than the USGS and were reviewed along with the other major ion and pH data using corroborating data methods. Hydrochemical studies reviewed in this qualification report indicate that the extent and quality of corroborating data are sufficient to support qualification of both USGS and non-USGS major ion and pH data for generalized hydrochemical studies. The corroborating data included other major ion and pH data, isotope data, and independent hydrological data. Additionally, the analytical adequacy of the major ion data was supported by a study of anion-cation charge balances. Charge balance errors for USGS and non-USGS data were under 10% and acceptable for all data. This qualification report addresses the specific major ion data sets

  15. 49 CFR 391.11 - General qualifications of drivers.

    Science.gov (United States)

    2010-10-01

    ... understand highway traffic signs and signals in the English language, to respond to official inquiries, and... QUALIFICATIONS OF DRIVERS AND LONGER COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Qualification and... motor vehicle unless he/she is qualified to drive a commercial motor vehicle. Except as provided in...

  16. 29 CFR 1926.1076 - Qualifications of dive team.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Qualifications of dive team. 1926.1076 Section 1926.1076 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... § 1926.1076 Qualifications of dive team. Note: The requirements applicable to construction work under...

  17. Review of qualifications for fuel assembly fabrication

    International Nuclear Information System (INIS)

    Slabu, Dan; Zemek, Martin; Hellwig, Christian

    2013-01-01

    The required quality of nuclear fuel in industrial production can only be assured by applying processes in fabrication and inspection, which are well mastered and have been proven by an appropriate qualification. The present contribution shows the understanding and experiences of Axpo with respect to qualifications in the frame of nuclear fuel manufacturing and reflects some related expectations of the operator. (orig.)

  18. Re-qualification of switchgear equipment following field modification

    International Nuclear Information System (INIS)

    Tulk, J.D.; El Bestawi, M.A.

    1984-01-01

    A set of 4.16 kV switchgear was seismically qualified by shaker table test for use in a nuclear power plant. Later, the equipment was modified by the addition of two extra switches and enclosures. This paper describes the methods used to extend the qualification achieved in the original proof test to the new configuration. Qualification of the modified switchgear depended on demonstrating that the intensity of the shaking that would be experienced by equipment mounted in the extended enclosure during a design basis earthquake (DBE) would be no stronger than the shaking that occurred during the original qualification testing. This was accomplished by a combination of analysis and experiment. Natural frequencies and mode-shapes of the original and extended enclosure structures were determined through in-situ modal tests on the equipment. Mathematical models based on the experimental results were then used for dynamic analyses which generated two sets of in-equipment response spectra: one set representing the original qualification test; and one set representing the response of the modified equipment to a hypothetical DBE. Qualification was confirmed by demonstrating that the test-based response spectra for the original configuration exceeded the response spectra developed for the extended structure subjected to DBE level excitation

  19. Qualification, certification and training systems of a Japanese nuclear power plant supplier

    International Nuclear Information System (INIS)

    Yoshijima, S.; Tomita, J.; Yoneda, Y.

    1982-01-01

    Training and indoctrination of personnel are very important for performing quality assurance activities in nuclear power plants. The paper presents policies, procedures and practices with regard to a training system for site construction workers, a training system for plant operation personnel at a special facility, and services and activities for operating plants. The training system for site workers and technicians offers basic training for all workers, and special training and qualification for field welders, cable-termination workers and non-destructive examination personnel. In addition to the qualification system for field welders applied by the regulatory body, a privat-company qualification system exists. Also, a training centre for BWR operators has been established. This facility has a simulator duplicating the main control room of an actual plant and a computer-assisted instruction system. Standard training courses, short-term basic courses, re-training courses, group training courses and special training courses are held at the training centre. Finally, the services and activities performed by Toshiba Corporation for operating plants are described. These activities of the plant supplier aim at keeping up and further enhancing the safety and reliability of operating plants and mainly consist of: (1) collection and evaluation of plant operation data, with re-evaluation and improvement of systems and components; (2) development of new maintenance techniques; (3) development of measures for reducing annual outage periods; and (4) plant emergency preparedness. (author)

  20. Open-Source RTOS Space Qualification: An RTEMS Case Study

    Science.gov (United States)

    Zemerick, Scott

    2017-01-01

    NASA space-qualification of reusable off-the-shelf real-time operating systems (RTOSs) remains elusive due to several factors notably (1) The diverse nature of RTOSs utilized across NASA, (2) No single NASA space-qualification criteria, lack of verification and validation (V&V) analysis, or test beds, and (3) different RTOS heritages, specifically open-source RTOSs and closed vendor-provided RTOSs. As a leader in simulation test beds, the NASA IV&V Program is poised to help jump-start and lead the space-qualification effort of the open source Real-Time Executive for Multiprocessor Systems (RTEMS) RTOS. RTEMS, as a case-study, can be utilized as an example of how to qualify all RTOSs, particularly the reusable non-commercial (open-source) ones that are gaining usage and popularity across NASA. Qualification will improve the overall safety and mission assurance of RTOSs for NASA-agency wide usage. NASA's involvement in space-qualification of an open-source RTOS such as RTEMS will drive the RTOS industry toward a more qualified and mature open-source RTOS product.