WorldWideScience

Sample records for iatrogenic aortic valve

  1. Aortic Valve Regurgitation

    Science.gov (United States)

    ... correct direction. These valves include the mitral valve, tricuspid valve, pulmonary valve and aortic valve. Each valve has ... Causes of aortic valve regurgitation include: Congenital heart valve disease. You may have been born with an aortic ...

  2. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  3. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  4. Bicuspid Aortic Valve

    Science.gov (United States)

    2006-08-01

    with tricuspid aortic valves matched for age, gender and grade of valvular disease . These studies suggest that the predisposition for aortic...enlargement in healthy patients with normally functioning BAV when compared to healthy subjects with normally functioning tricuspid aortic valves ...ascending aorta but also in the pulmonary arteries of patients with BAV, compared to that of patients with tricuspid aortic valves . These studies

  5. Aortic Valve Disease

    Science.gov (United States)

    ... It is then replaced with an artificial valve (prosthesis). There are two valve options for aortic valve ... place, the catheter will be withdrawn from your body through the original access point. Because not all ...

  6. Aortic valve surgery - open

    Science.gov (United States)

    ... while you are connected to this machine. This machine does the work of your heart while your heart is stopped. If your aortic valve is too damaged, you will need a new valve. This is called replacement surgery. Your surgeon will remove your aortic valve ...

  7. Aortic Valve Leaflet Perforation after Mitral Valve Repair

    Directory of Open Access Journals (Sweden)

    M. Aboelnasr

    2013-01-01

    Full Text Available  A 32-year-old patient with symptomatic severe aortic regurge, 6 weeks after mitral valve repair, was admitted for aortic valve surgery. No preoperative clinical data consistent with infective endocarditis could be detected. Preoperative transthoracic echocardiography showed aortic leaflet perforation affecting non coronary cusp. During operation, leaflet perforation was detected and closed completely with autologous pericardial patch. No vegetations or abscess could be seen during operation. Iatrogenic aetiology of leaflet perforation after mitral repair was suspected in  this case. Recognition of this complication will help in  avoiding it during mitral valve surgery and expecting it as a possible complication during intraoperative transesophageal echocardiography.

  8. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  9. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... assigned to the 'small' aortic size subset. Effective orifice area indices were calculated for all patients to assess the geographic distribution of patient-prosthesis mismatch. Univariable and multivariable logistic regression analyses adjusting for possible confounding variables were performed. RESULTS...

  10. [Traumatic aortic valve insufficiency].

    Science.gov (United States)

    Nascimento, J; Lemos, C; Marques, A M; Antunes, M J; Gonsalves, A

    1996-02-01

    The traumatic aortic valvular insufficiency (TAVI), through less frequent after a non-penetrating thoracic traumatism, is a serious entity with a very reserved prognosis. So it must be suspected in every patients with signs or symptoms of de novo heart failure post-traumatism. The transthoracic echocardiography and eventually transesophageal echocardiography have a fundamental role in the confirmation of the diagnosis. The clinical picture of traumatic aortic regurgitation is quickly evolutionary and the non efficacy of medical therapy has placed the valvular substitution surgery as the best succeeded treatment. With the advent of the aortic valve repairing surgery some TAVI cases has been submitted to this procedure. Nevertheless, the development of residual aortic regurgitation in these situations, usually requiring later valvular replacement surgery, make the aortic valvuloplasty a controversial surgical technique. The AA describe a recent clinical case of aortic regurgitation after a non-penetrant thoracic traumatism, discussing the aspects connected with physiopathology, diagnosis and therapy. The singularity of this case was based on the fact that the initial clinical diagnosis had been prejudiced by the context of a polytraumatism and there had been a time free of symptoms between the traumatism and the beginning of the symptomatology of left ventricular failure. Even though the identification of the problem allowed an intensive treatment of this serious situation that ended with the replacement of the aortic valve by mechanical aortic prosthesis, with the patient's total recovery.

  11. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  12. Bicuspid aortic valve

    Science.gov (United States)

    ... females. A BAV often exists in babies with coarctation of the aorta (narrowing of the aorta). BAV is also seen ... to view the blood vessels of the heart Treatment ... to the heart and into the narrow opening of the aortic valve. A balloon attached to the end of ...

  13. Subacute Aortic Regurgitation as a Rare Presentation of Latrogenic Aortic Valve Leaflet Perforation

    Directory of Open Access Journals (Sweden)

    Hassan Teimouri

    2009-12-01

    Full Text Available There is a paucity of literature regarding iatrogenic aortic valve perforation after cardiac operation is performed in the vicinity of the aortic valve. This report describes the clinical, echocardiographic, and angiocardiographic recognition of iatrogenic aortic valve perforation in a patient who had previously under gone membranous ventricular septal defect and pulmonary stenosis. Five days after the operation, the patient showed subacute signs and symptoms of congestive heart failure in surgical ward. Echocardiographic examination revealed free aortic regurgitation. The patient was scheduled for operation, which was performed using cardiopulmonary bypass and cardioplegic arrest. During the operation, exploration of the aortic root revealed tearing non-coronary aortic cusp at the level of the aortic ring and slightly dilated the left sinus. Despite close examination, no suture could be identified. It was reasoned that the tension created by the dacron patch pulled on the adjacent tissue and caused the separation of the non-coronary cusp from its ring and the patient was treated by aortic valve replacement with prosthetic aortic valve. We did not have the facility to use transesophaseal echocardiography for the examination of aortic valve repair and the poor condition of the patient did not permit us to repair the valve. Precise preoperative diagnosis of this lesion allows optimal surgical planning and treatment.

  14. Quadricuspid Aortic Valve Combined with Moderate Ascending Aortic Dilatation

    Science.gov (United States)

    Uspenskiy, Vladimir E.; Osadchii, Alexei M.; Gordeev, Mikhail L.

    2015-01-01

    The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography. PMID:27390747

  15. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  16. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  17. Transcatheter Aortic Valve Replacement for Perceval Sutureless Aortic Valve Failure.

    Science.gov (United States)

    Kalra, Ankur; Reyes, Manuel; Yang, Eric Y; Little, Stephen H; Nabi, Faisal; Barker, Colin M; Ramchandani, Mahesh; Reul, Ross M; Reardon, Michael J; Kleiman, Neal S

    2017-06-01

    As experience with Perceval aortic prosthesis and valve-in-valve TAVR grows, it will be crucial to meticulously document short- and long-term follow-up for establishment of real-world safety and durability of these new technologies.

  18. Mitral Valve Aneurysm: A Rare Complication of Aortic Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    A Moaref

    2008-11-01

    Full Text Available A 20-year-old intravenous drug abuser man, refered to our hospital with dyspnea and orthopnea. Tranesophagealechocardiography revealed severe aortic regurgitation, healed vegetation of aortic valve and an aneurysm of theanterior leaflet of the mitral valve. The patient was discharged after aortic valve replacement and mitral valverepair.

  19. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  20. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  1. Cellular Mechanisms of Aortic Valve Calcification.

    Science.gov (United States)

    Zhiduleva, E V; Irtyuga, O B; Shishkova, A A; Ignat'eva, E V; Kostina, A S; Levchuk, K A; Golovkin, A S; Rylov, A Yu; Kostareva, A A; Moiseeva, O M; Malashicheva, A B; Gordeev, M L

    2018-01-01

    Comparative in vitro study examined the osteogenic potential of interstitial cells of aortic valve obtained from the patients with aortic stenosis and from control recipients of orthotopic heart transplantation with intact aortic valve. The osteogenic inductors augmented mineralization of aortic valve interstitial cells (AVIC) in patients with aortic stenosis in comparison with the control level. Native AVIC culture of aortic stenosis patients demonstrated overexpression of osteopontin gene (OPN) and underexpression of osteoprotegerin gene (OPG) in comparison with control levels. In both groups, AVIC differentiation was associated with overexpression of RUNX2 and SPRY1 genes. In AVIC of aortic stenosis patients, expression of BMP2 gene was significantly greater than the control level. The study revealed an enhanced sensitivity of AVIC to osteogenic inductors in aortic stenosis patients, which indicates probable implication of OPN, OPG, and BMP2 genes in pathogenesis of aortic valve calcification.

  2. Imaging techniques in transcatheter aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Quaife RA

    2013-11-01

    Full Text Available Robert A Quaife, Jennifer Dorosz, John C Messenger, Ernesto E Salcedo Division of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Calcific aortic stenosis is now understood as a complex valvular degenerative process sharing many risk factors with atherosclerosis. Once patients develop symptomatic calcific aortic stenosis, the only effective treatment is aortic valve replacement. In the past decade, transcatheter aortic valve replacement (TAVR has been developed as an alternative to surgery to treat severe calcific aortic stenosis. Cardiac imaging plays a pivotal role in the contemporary management of patients with calcific aortic stenosis, and particularly in patients being considered for TAVR, who demand detailed imaging of the aortic valve apparatus. In this review, we highlight the role of cardiac imaging for patient selection, procedural guidance, and evaluation of results of TAVR. Keywords: aortic stenosis, cardiovascular imaging, transcutaneous aortic valve replacement

  3. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  4. Artificial aortic valves: an overview.

    Science.gov (United States)

    Morsi, Y S; Birchall, I E; Rosenfeldt, F L

    2004-06-01

    This review discusses strategies that may address some of the limitations associated with replacing diseased or dysfunctional aortic valves with mechanical or tissue valves. These limitations range from structural failure and thromboembolic complications associated with mechanical valves to a limited durability and calcification with tissue valves. In pediatric patients there is an issue with the inability of substitutes to grow with the recipient. The emerging science of tissue engineering potentially provides an attractive alternative by creating viable tissue structures based on a resorbable scaffold. Morphometrically precise, biodegradable polymer scaffolds may be fabricated from data obtained from scans of natural valves by rapid prototyping technologies such as fused deposition modelling. The scaffold provides a mechanical profile until seeded cells produce their own extra cellular matrix. The microstructure of the forming tissue may be aligned into predetermined spatial orientations via fluid transduction in a bioreactor. Although there are many technical obstacles that must be overcome before tissue engineered heart valves are introduced into routine surgical practice these valves have the potential to overcome many of the shortcomings of current heart valve substitutes.

  5. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  6. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  7. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  8. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  9. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR...

  10. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  11. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  12. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    Science.gov (United States)

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  13. Aortic valve regurgitation and the congenitally bicuspid aortic valve: a clinico-pathological correlation

    NARCIS (Netherlands)

    Sadee, A. S.; Becker, A. E.; Verheul, H. A.; Bouma, B.; Hoedemaker, G.

    1992-01-01

    To investigate the morphology of congenitally bicuspid aortic valves causing pure valve regurgitation. A case series collected over five years. An academic hospital. One hundred and forty eight excised congenitally bicuspid aortic valves. The morphological findings were correlated with sex, age,

  14. Massive Thoracoabdominal Aortic Thrombosis in a Patient with Iatrogenic Cushing Syndrome

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Choi, Dong Hyun; Lee, Young Min; Kim, Bo Bae; Ki, Young Jae; Kim, Jin Hwa; Chung, Joong Wha; Koh, Young Youp; Kang, Joon Tae; Chae, Seung Seok

    2014-01-01

    Massive thoracoabdominal aortic thrombosis is a rare finding in patients with iatrogenic Cushing syndrome in the absence of any coagulation abnormality. It frequently represents an urgent surgical situation. We report the case of an 82-year-old woman with massive aortic thrombosis secondary to iatrogenic Cushing syndrome. A follow-up computed tomography scan showed a decreased amount of thrombus in the aorta after anticoagulation therapy alone.

  15. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  16. Quadricuspid Aortic Valve Combined with Moderate Ascending Aortic Dilatation: A Report of Four Cases.

    Science.gov (United States)

    Uspenskiy, Vladimir E; Osadchii, Alexei M; Gordeev, Mikhail L

    2015-12-01

    The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography.

  17. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we report a case of an antenatal female in first trimester with aortic prosthetic valve thrombosis (PVT), who was successfully ...

  18. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  19. Imaging techniques in aortic valve and root surgery

    NARCIS (Netherlands)

    Regeer, M.V.

    2017-01-01

    Aortic valve sparing surgery for aortic regurgitation and/or aortopathy serves as an alternative to aortic valve and root replacement. One of the advantages of aortic valve sparing surgery over conventional replacement is that there is no need for life-long anticoagulation, which is particularly

  20. The bicuspid aortic valve and related disorders

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Bicuspid aortic valve (BAV is the most common congenital cardiac malformation, affecting 1-2% of the population, with strong male predominance. Individuals may have a normally functioning BAV, and may be unaware of its presence and the potential risk of complications. However, they may easily develop aortic valve disorders: either stenotic or regurgitant, or both. Today, BAV is recognized as a syndrome incorporating aortic valve disorders and aortic wall abnormalities, including aortic dilation, dissection or rupture. Congenital or hereditary diseases such as ventricular septal defect, patent ductus arteriosus, coarctation of the aorta, Turner's syndrome, Marfan's syndrome etc., may frequently be associated with BAV. Infective endocarditis and occasionally thrombus formation may develop during the lives of BAV patients. Elevated cholesterol or C-reactive protein may be seen in laboratory findings of these patients. Beta-blockers and statins are the possibilities for medical treatment, and aortic valve repair/replacement and ascending aorta replacement are indicated for patients with a severely diseased aortic valve and aorta. Rigorous follow-up throughout life is mandatory after BAV has been diagnosed. The aim of the present article was to describe the implications of BAV and its associated disorders, and to discuss diagnostic and treatment strategies.

  1. Sequential transcatheter aortic valve implantation due to valve dislodgement

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected fo...

  2. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung Han; Lefèvre, Thierry; Ahn, Jung Ming

    2016-01-01

    Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices.  Objective...

  3. Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung-Han; Bleiziffer, Sabine; De Backer, Ole

    2017-01-01

    BACKGROUND: Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). OBJECTIVES: This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR mul...

  4. A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis

    DEFF Research Database (Denmark)

    Nielsen, Hans Henrik Møller; Klaaborg, Kaj E; Nissen, Henrik

    2012-01-01

    In a prospective randomised trial we aimed to compare transapical transcatheter aortic valve implantation (a-TAVI) with surgical aortic valve replacement (SAVR) in operable elderly patients.......In a prospective randomised trial we aimed to compare transapical transcatheter aortic valve implantation (a-TAVI) with surgical aortic valve replacement (SAVR) in operable elderly patients....

  5. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  6. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  7. Surgical anatomy of the aortic root: Implication for valve-sparing reimplantation and aortic valve annuloplasty

    OpenAIRE

    de Kerchove, Laurent; Jashari, Ramadan; Boodhwani, Munir; Duy, Khanh Tran; Lengelé, Benoit; Gianello, Pierre; Nezhad, Zahra Mozala; Astarci, Parla; Noirhomme, Philippe; El Khoury, Gebrine

    2015-01-01

    BACKGROUND: To enhance the reproducibility of aortic valve-sparing reimplantation and annuloplasty, we analyzed the topographic relationship between the ventriculoaortic junction (VAJ), basal ring (BR), and sinotubular junction (STJ). The root base thickness is also quantified. METHOD: Fifty-eight fresh human aortic valves were analyzed. The root was dissected to the limit where the aortic wall terminates into the cardiac structures (VAJ). Root height was measured externally from the STJ t...

  8. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen...

  9. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  11. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  12. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  13. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis

    DEFF Research Database (Denmark)

    Siontis, George C M; Praz, Fabien; Pilgrim, Thomas

    2016-01-01

    AIMS: In view of the currently available evidence from randomized trials, we aimed to compare the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the spectrum of risk and in important subgroups. METHODS AND RESULTS......: Trials comparing TAVI vs. SAVR were identified through Medline, Embase, and Cochrane databases. The primary outcome was death from any cause at 2 years. We performed random-effects meta-analyses to combine the available evidence and to evaluate the effect in different subgroups. This systematic review...... and meta-analysis is registered with PROSPERO (CRD42016037273). We identified four eligible trials including 3806 participants, who were randomly assigned to undergo TAVI (n = 1898) or SAVR (n = 1908). For the primary outcome of death from any cause, TAVI when compared with SAVR was associated...

  14. Aortic valve replacement in octogenarians

    Directory of Open Access Journals (Sweden)

    Dark John H

    2007-07-01

    Full Text Available Abstract Background and Aims As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR in octogenarians. Methods 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37 underwent isolated AVR whilst 46% (31 underwent combined AVR and CABG. Results Follow up was 100% complete. The mean age was 83.1 ± s.d. 2.9 years, a mean gradient of 83 ± s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 ± s.d. 1.2, the logistic EuroSCORE mean 12.0 ± s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p Conclusion Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  15. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  16. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  17. Emergency Valve-in-Valve Transcatheter Aortic Valve Implantation for the Treatment of Acute Stentless Bioprosthetic Aortic Insufficiency and Cardiogenic Shock

    Directory of Open Access Journals (Sweden)

    Ivan D. Hanson

    2018-01-01

    Full Text Available Bioprosthetic aortic valve degeneration may present as acute, severe aortic regurgitation and cardiogenic shock. Such patients may be unsuitable for emergency valve replacement surgery due to excessive risk of operative mortality but could be treatable with transfemoral valve-in-valve transcatheter aortic valve implantation (TAVI. There is a paucity of data regarding the feasibility of valve-in-valve TAVI in patients presenting with cardiogenic shock due to acute aortic insufficiency from stentless bioprosthetic valve degeneration. We present one such case, highlighting the unique aspects of valve-in-valve TAVI for this challenging patient subset.

  18. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  20. Mechanical Aortic Valve Replacement in Octogenarian

    Directory of Open Access Journals (Sweden)

    Irfan Tasoglu

    2013-10-01

    Full Text Available Aim: This study analyzes the long-term outcomes of mechanical aortic valve replacement in octogenarian patients. Material and Method: A retrospective review was performed on 23 octogenarian patients who underwent mechanical aortic valve replacement. Hospital mortality, postoperative intensive care unit stay, hospital stay and long-term results was examined. Estimates of the cumulative event mortality rate were calculated by the Kaplan-Meier method. Results: The mean age of all patients was 82.9±2.3 years and most were men (65.22%. The median ejection fraction was 45%. 73.91% of patients were in New York Heart Association class III-IV. Thirteen patients (56.52% in this study underwent combined procedure, the remaining 10 (43.48% patients underwent isolated aortic valve replacement. The most common valve size was 23 mm. The mean intensive care unit stay was 1.76±1.14 days. The mean hospital stay was 9.33±5.06 days. No complications were observed in 56.52% patients during their hospital stay. The overall hospital mortality was 8.7%. Follow-up was completed for all 23 patients. Median follow-up time was 33 months (1-108 months. Actuarial survival among discharged from hospital was 59% at 5 years. Discussion: Mechanical aortic valve replacement is a safe procedure in octogenarian patients and can be performed safely even in combined procedure.

  1. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  2. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  3. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    or worse postprocedural paravalvular regurgitation (hazard ratio, 4.0 [1.5-11]), implantation of >1 prosthesis (hazard ratio, 5.2 [1.5-18]), and any vascular complication (hazard ratio, 3.8 [1.5-9.8]). CONCLUSIONS: TAVI-PVE occurred at a slightly higher rate than reported for surgically implanted valves...... risk factors. METHODS AND RESULTS: Observational single-center study of 509 consecutive patients treated with a transcatheter implanted self-expandable aortic valve prosthesis (Medtronic CoreValve). We identified 18 patients diagnosed with TAVI-PVE during a median follow-up period of 1.4 years...

  4. [Aortic valve-sparing root reconstruction in Marfan syndrome].

    Science.gov (United States)

    Ogino, H; Sasaki, H; Hanafusa, Y; Hirata, M; Numata, S; Ando, M; Yagihara, T; Kitamura, S

    2002-07-01

    The outcome of aortic valve-sparing root reconstruction in Marfan syndrome was reviewed. Thirteen patients with Marfan syndrome underwent aortic valve-sparing root reconstruction for annuloaortic ectasia or aortic root dissection between 1994 and 1999. The grade of preoperative aortic regurgitation was I in 4, II in 2, III in 5, IV in 2 patients. The procedures of aortic valve-sparing were reimplantation in 7 and remodeling in 5 patients. There was no hospital and late death. Recurrence of aortic regurgitation greater than moderate grade developed in 1 patient immediately after the surgery and in the other 4 patients in the late stage. One patient of them required aortic valve replacement for it. Aortic valve-sparing root reconstruction is applicable in Marfan patients, although the indication should be cautious. Close observation is needed for recurrence of aortic regurgitation.

  5. Autopsy after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    van Kesteren, F.; Wiegerinck, E. M. A.; Rizzo, S.; Baan, J.; Planken, R. N.; von der Thüsen, J. H.; Niessen, H. W. M.; van Oosterhout, M. F. M.; Pucci, A.; Thiene, G.; Basso, C.; Sheppard, M. N.; Wassilew, K.; van der Wal, A. C.

    2017-01-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview of

  6. Severe aortic valve stenosis and nosebleed

    NARCIS (Netherlands)

    Schoedel, Johannes; Obergfell, Achim; Maass, Alexander H.; Schodel, Johannes

    2007-01-01

    Aortic valve stenosis is known to be associated with loss of high molecular von Willebrand multimers. This can lead to gastrointestinal bleeding in patients with gastrointestinal angiodysplasia, the Heyde syndrome. Here we present a case of anaemia and severe epistaxis associated with acquired von

  7. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  8. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... valve surgery. Techniques include min-thoracotomy, min-sternotomy, robot-assisted surgery, and percutaneous surgery. To perform the ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  9. Aortic elasticity and size are associated with aortic regurgitation and left ventricular dysfunction in tetralogy of Fallot after pulmonary valve replacement

    NARCIS (Netherlands)

    Grotenhuis, H.B.; Ottenkamp, J.; de Bruijn, L.; Westenberg, J.J.M.; Vliegen, H.W.; Kroft, L.J.M.; de Roos, A.

    2009-01-01

    Background: Aortic wall pathology and concomitant aortic dilatation have been described in tetralogy of Fallot (TOF) patients, which may negatively affect aortic valve and left ventricular systolic function. Objective: To assess aortic dimensions, aortic elasticity, aortic valve competence and

  10. Transcatheter Aortic Valve Replacement With Different Valve Types in Elliptic Aortic Annuli.

    Science.gov (United States)

    Maeno, Yoshio; Abramowitz, Yigal; Yoon, Sung-Han; Jilaihawi, Hasan; Raul, Sharma; Israr, Sharjeel; Miyasaka, Masaki; Kawamori, Hiroyuki; Kazuno, Yoshio; Rami, Tanya; Takahashi, Nobuyuki; Mangat, Geeteshwar; Kashif, Mohammad; Chakravarty, Tarun; Nakamura, Mamoo; Cheng, Wen; Makkar, Raj R

    2017-06-23

    The aim of this study was to determine the influence of an elliptic annulus on acute device success rates following self-expanding (SE) transcatheter aortic valve replacement (TAVR) vs. balloon-expandable (BE) TAVR.Methods and Results:Outcomes were assessed using Valve Academic Research Consortium-2 definitions. Aortic annulus ratio (AAR) was measured as short axis diameter/long axis diameter. Mean AAR was 0.81±0.06. Patients were therefore divided into 2 groups: AAR elliptic annuli, SE-TAVR was an independent predictor of unsuccessful device implantation (OR, 6.34, Pelliptic annuli was associated with an exponential rise in device success (threshold ≥17.5%; area under the curve, 0.83) but not for BE-TAVR. Furthermore, optimally oversized SE valves and BE valves had a similarly high device success for elliptic annuli (SE valve, 96.2% vs. BE valve, 95.3%). For circular annuli, similarly high device success was achieved for the 2 valve types. Conversely, for elliptic annuli, SE valves had a lower device success than BE valves. Device success following optimal oversizing of SE valves, however, was similar to that for BE valves.

  11. Incidental necropsy finding of a quadricuspid aortic valve

    NARCIS (Netherlands)

    van Rijswijk, Jan Willem; Willemink, Martin; Kluin, Jolanda; Vink, Aryan

    2015-01-01

    Quadricuspid aortic valve is a rare congenital cardiac malformation often associated with abnormal valve function. In this article, we present a case of quadricuspid aortic valve only diagnosed at the time of post-mortem examination. (C) 2015 Elsevier Inc. All rights reserved.

  12. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  13. Global Strain in Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2012-01-01

    BACKGROUND: -Global longitudinal systolic strain (GLS) is often reduced in aortic stenosis despite normal ejection fraction. The importance of reduced preoperative GLS on long-term outcome after aortic valve replacement (AVR) is unknown. METHODS AND RESULTS: -A total of 125 patients with severe...... quartile 49% (n=15), p=0.04. Patients with increased age, left ventricular hypertrophy and left atrial dilatation were at increased risk. In Cox regression analysis after correcting for standard risk factors and ejection fraction, GLS was found to be significantly associated with cardiac morbidity...

  14. Human tissue valves in aortic position: determinants of reoperation and valve regurgitation

    NARCIS (Netherlands)

    T.P. Willems (Tineke); E.W. Steyerberg (Ewout); V.E. Kleyburg-Linkers; E. Bos (Egbert); L.A. van Herwerden (Lex); J.R.T.C. Roelandt (Jos); J.J.M. Takkenberg (Hanneke)

    2001-01-01

    textabstractBACKGROUND: Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve

  15. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Aortic valve ochronosis: a rare manifestation of alkaptonuria

    Science.gov (United States)

    Steger, Christina Maria

    2011-01-01

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837

  17. Early Outcomes of Sutureless Aortic Valves

    Directory of Open Access Journals (Sweden)

    Muhammet Onur Hanedan

    2016-06-01

    Full Text Available Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7% were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69% died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  18. Midterm outcomes after transcatheter aortic valve implantation.

    Science.gov (United States)

    Lotfi, Shahram; Dohmen, Guido; Götzenich, Andreas; Haushofer, Marcus; Spillner, Jan Wilhelm; Autschbach, Rüdiger; Hoffmann, Rainer

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) has become a therapeutic option for high-risk or nonoperable patients with severe symptomatic aortic valve stenosis. The best known and most frequently implanted prostheses are the CoreValve and SAPIEN prostheses. We report our experiences and analyze the results of our TAVI program. A total of 357 patients underwent transfemoral (TF) and transapical (TA) TAVI in our center between January 2008 and October 2012. The procedure was performed in 190 patients with CoreValve, in 155 patients with SAPIEN, and in 12 patients with ACURATE TA prostheses. Transfemoral access was used in 190 patients. In 167 patients, TA access was used. The mean age was 80.2 ± 6.4 years. All patients were nonoperable or had a high risk for a conventional aortic valve replacement. The mean logistic EuroSCORE I was 25.92 ± 14.51%. The TF/CoreValve (190 patients) and TA/SAPIEN (155 patients) groups showed significant difference in the patients' mean age (81.7 ± 6.3 years vs. 79.5 ± 6.6 years, P = 0.002) and in mean logistic EuroSCORE I (22.16 ± 13.05% vs. 31.04 ± 16.40, P < 0.001). The overall 30-day mortality (357 patients) was 9.80% (TF, 8.42%; TA, 11.37%); overall 1-year mortality (275 patients), 21.45% (TF, 23.74%; TA, 19.12%); overall 2-year mortality (199 patients), 29.15% (TF, 35.96%; TA, 23.64%); overall 3-year mortality (133 patients), 37.59% (TF, 43.86%; TA, 32.89%); and overall 4-year mortality (38 patients), 39.47% (TF, 45%; TA, 33.33%). The rate of pacemaker implantation after TAVI was significantly higher in the CoreValve group than in the SAPIEN group: 44.74% (85/190 patients) versus 6.45% (10/155 patients), P < 0.001. Stroke rate was higher in the TF-CoreValve group than in the TA-SAPIEN group: 4.21% versus 0.64%, P = 0.045. Outcomes after TAVI were, in our population of nonoperable and high-risk patients, encouraging. The differences in midterm outcomes between the TF-CoreValve TAVI and the TA-SAPIEN TAVI were not significant.

  19. [Current results of the aortic valve changes].

    Science.gov (United States)

    López Soriano, F; Barnet, J C; Quijano Pitman, F

    1979-01-01

    The prosthetic substitution of the aortic valve has experienced a great advance over the last years in relation with the surgical and hospital mortality. In the personal experience of one of the authors (F. López Soriano), the mortality rate was 0% in 40 patients in which an aortic valve change was performed, isolated or associated to other pathology. Between 1973 and 1978, 167 patients were operated at the "Instituto Nacional de Cardiología", with an early mortality of 11.3%; these results were superior to those previously published. The percentage of myocardic infarction following surgery was similar in both groups 8% less, than the 15% reported in other statistics. 25 patients of the total group needed second surgery due to prosthetic malfunction. A Starr Edward Model 2320 had been implanted on most patients, known for the high percentage of malfunction which is being discarted at present. Thromboembolic phenomena occurred in 9 patients (5.3%) from which five were located in the brain, none of them being fatal. The present results justify early surgery in moderately sinthomatic aortic valve disease, when comparing these results with the natural history of the disease and the evolution of said patients operated in later stages.

  20. Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2015-01-01

    clinical trial compared TAVR with surgical aortic valve replacement (SAVR) in an all-comers patient cohort. METHODS: Patients ≥ 70 years old with severe aortic valve stenosis and no significant coronary artery disease were randomized 1:1 to TAVR using a self-expanding bioprosthesis versus SAVR. The primary...... difference in the primary endpoint was found (13.1% vs. 16.3%; p = 0.43 for superiority). The result did not change in the as-treated population. No difference in the rate of cardiovascular death or prosthesis reintervention was found. Compared with SAVR-treated patients, TAVR-treated patients had more...... conduction abnormalities requiring pacemaker implantation, larger improvement in effective orifice area, more total aortic valve regurgitation, and higher New York Heart Association functional class at 1 year. SAVR-treated patients had more major or life-threatening bleeding, cardiogenic shock, acute kidney...

  1. Vascular complications associated with transcatheter aortic valve replacement.

    Science.gov (United States)

    Sardar, M Rizwan; Goldsweig, Andrew M; Abbott, J Dawn; Sharaf, Barry L; Gordon, Paul C; Ehsan, Afshin; Aronow, Herbert D

    2017-06-01

    Transcatheter aortic valve replacement (TAVR) is now an accepted pathway for aortic valve replacement for patients who are at prohibitive, severe and intermediate risk for traditional aortic valve surgery. However, with this rising uptrend and adaptation of this new technology, vascular complications and their management remain an Achilles heel for percutaneous aortic valve replacement. The vascular complications are an independent predictor of mortality for patients undergoing TAVR. Early recognition of these complications and appropriate management is paramount. In this article, we review the most commonly encountered vascular complications associated with currently approved TAVR devices and their optimal percutaneous management techniques.

  2. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  3. Valve mediated hemodynamics and their association with distal ascending aortic diameter in bicuspid aortic valve subjects.

    Science.gov (United States)

    Raghav, Vrishank; Barker, Alex J; Mangiameli, Daniel; Mirabella, Lucia; Markl, Michael; Yoganathan, Ajit P

    2018-01-01

    Valve mediated hemodynamics have been postulated to contribute to pathology of the ascending aorta (AAo). The objective of this study is to assess the association of aortic valve morphology and hemodynamics with downstream AAo size in subjects with bicuspid aortic valve (BAV) disease. Four-dimensional flow MRI at 1.5 or 3 Tesla was used to evaluate the hemodynamics in the proximal AAo of 52 subjects: size-matched controls with tricuspid aortic valves (n = 24, mid ascending aorta [MAA] diameter = 38.0 ± 4.9 mm) and BAV patients with aortic dilatation (n = 14 right and left coronary leaflet fusion [RL]-BAV, MAA diameter = 38.1 ± 5.3 mm; n = 14 right and noncoronary leaflet fusion [RN]-BAV, MAA diameter = 36.5 ± 6.6 mm). A validated semi-automated technique was used to evaluate hemodynamic metrics (flow angle, flow displacement, and jet quadrant) and valve morphology (orifice circularity) for all subjects. Regression analysis of these metrics to AAo diameter was performed. RN-BAV subjects displayed a stronger correlation between hemodynamic metrics in the proximal AAo with diameter in the distal AAo compared with size-matched tricuspid aortic valve (TAV) controls and RL-BAV subjects. The distal AAo diameter was found to be strongly correlated to the upstream flow displacement (R 2 adjusted = 0.75) and flow angle (R 2 adjusted = 0.66) measured at the sino-tubular junction (STJ). Orifice circularity was also strongly correlated (R 2 adjusted = 0.53) to the distal AAo diameter in RN-BAV subjects. For TAV controls and RL-BAV subjects, correlations were weaker (R 2 adjusted valve morphology metrics. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:246-254. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  5. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  6. Transcatheter aortic valve implantation with Core Valve: First Indian experience of three high surgical risk patients with severe aortic stenosis

    Directory of Open Access Journals (Sweden)

    Ashok Seth

    2013-07-01

    Full Text Available The prevalence of aortic stenosis is increasing with aging population. However with multiple co-morbidities and prior procedures in this aging population, more and more patients are being declared unfit for the ‘Gold Standard’ treatment i.e. surgical aortic valve replacement (AVR. Among the patients who are unfit or high risk for aortic valve replacement (AVR by open heart surgery, transcatheter aortic valve implantation (TAVI has been proven to be a valuable alternative improving survival and quality of life. We report first Indian experience of Core Valve (Medtronic Inc. implantation in three high surgical risk patients performed on 22nd and 23rd February 2012.

  7. When operable patients become inoperable: conversion of a surgical aortic valve replacement into transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Arendrup, Henrik; Engstrøm, Thomas

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) is a relatively new treatment option for inoperable patients with severe aortic stenosis (AS). This case describes how a planned conventional surgical aortic valve replacement (AVR) on a 73-year-old woman was successfully converted to a TAVI procedure....... On extracorporal circulation it was reconized that the aortic annulus, the coronary ostiae and the proximal part of the ascending aorta were severely calcified making valve implantation impossible. Surgical closure without valve substitution was estimated to be associated with a high risk of mortality due...

  8. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves

    Science.gov (United States)

    van Rensburg, Annari; Doubell, Anton

    2017-01-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P abnormal papillary muscles (P = 0.002) and an additional chord or tendon in the left ventricle cavity (P = 0.007). Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. PMID:28515127

  9. One stage surgical treatment of aortic valve disease and aortic coarctation with aortic bypass grafting through the diaphragm and aortic valve replacement.

    Science.gov (United States)

    Yu, Zipu; Wu, Shengjun; Li, Chengchen; Zou, Yu; Ma, Liang

    2015-11-10

    To validate ascending aorta-lower abdominal aorta bypass grafting treatment for patients with descending aortic coarctation and an aortic valve disease. The three patients in whom a descending atypical aortic coarctation was associated with an aortic valve disease were treated with one stage surgical treatment with aortic bypass grafting through the diaphragm and aortic valve replacement in our heart center. Operative technique consisted of performing ascending aorta-lower abdominal aorta bypass grafting through diaphragm muscle and implementing aortic valve replacement. The mean time for extracorporeal circulation and occluding clamp of aorta was recorded. Blood pressure data for pre- and post-operation was measured in the limbs. Computer-enhanced transvenous angiograms of pre- and post-operation were applied for detection of aortic stenosis. The other adverse events were noticed in outpatient service during a follow-up period. The mean extracorporeal circulation time was 54 ± 11 min. The mean time for occluding clamp of aorta was 34 ± 6 min. An arterial pressure gradient was totally corrected after surgical treatment. Post-operation computer-enhanced transvenous angiograms showed the grafts to be open with a fluent flow. The patients had no gastrointestinal tract complications. No adverse event was noticed during a follow-up period in outpatient service. Treatment of ascending aorta-lower abdominal aorta bypass is advisable for patients with descending aortic coarctation and an aortic valve disease.

  10. Delirium After Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Giuseffi, Jennifer L; Borges, Nyal E; Boehm, Leanne M; Wang, Li; McPherson, John A; Fredi, Joseph L; Ahmad, Rashid M; Ely, E Wesley; Pandharipande, Pratik P

    2017-07-01

    Postoperative delirium is associated with increased mortality. Patients undergoing transcatheter aortic valve replacement are at risk for delirium because of comorbid conditions. To compare the incidence, odds, and mortality implications of delirium between patients undergoing transcatheter replacement and patients undergoing surgical replacement. The Richmond Agitation-Sedation Scale and the Confusion Assessment Method for the Intensive Care Unit were used to assess arousal level and delirium prospectively in all patients with severe aortic stenosis who had transcatheter or surgical aortic valve replacement at an academic medical center. Multivariable logistic regression was used to determine the relationship between procedure type and occurrence of delirium. Cox regression was used to assess the association between postoperative delirium and 6-month mortality. A total of 105 patients had transcatheter replacement and 121 had surgical replacement. Patients in the transcatheter group were older (median age, 81 vs 68 years; P replacement. Delirium is less likely to develop in the transcatheter group but is associated with higher mortality in both groups. ©2017 American Association of Critical-Care Nurses.

  11. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  12. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  13. Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Gohlke-Bärwolf, Christa; Bahlmann, Edda

    2014-01-01

    To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are......To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are...

  14. Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves

    DEFF Research Database (Denmark)

    Makkar, Raj R; Fontana, Gregory; Jilaihawi, Hasan

    2015-01-01

    BACKGROUND: A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and pr...

  15. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  16. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas

    2017-01-01

    AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled...

  17. The future of surgical aortic valve replacement and the role of sutureless technology.

    Science.gov (United States)

    Isbir, Selim

    2018-04-01

    Aortic valve stenosis has become the most frequent type of valve disease in worldwide. Surgical aortic valve replacement is still the gold standard therapy. More recently transcatheter aortic valve implantation has been demonstrated to be not inferior in patients with high and intermediate risk patients. Sutureless aortic valves were designed to simplify the surgical aortic valve replacement. With the aid of this new technology, the invasiveness of surgery can be reduced with potential improvements in outcome.

  18. Simulation for transthoracic echocardiography of aortic valve

    Directory of Open Access Journals (Sweden)

    Navin C Nanda

    2016-01-01

    Full Text Available Simulation allows interactive transthoracic echocardiography (TTE learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve.

  19. Antithrombotic therapy after bioprosthetic aortic valve implantation

    DEFF Research Database (Denmark)

    Rafiq, Sulman; Steinbrüchel, Daniel Andreas; Lilleør, Nikolaj Bang

    2017-01-01

    Background The optimal medical strategy for prevention of thromboembolic events after surgical bioprosthetic aortic valve replacement (BAVR) is still debated. The objective of this study was to compare warfarin therapy (target INR of 2.0 to 3.0) with aspirin 150 mg daily as antithrombotic therapy...... for the first three months after BAVR with or without concomitant coronary artery bypass grafting (CABG). The aim was to evaluate thromboembolic complications, major bleeding complications and death. Materials and methods Prospective, single-centre, open-label, randomized controlled trial. 370 patients were...

  20. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  1. Aortic valve calcification as a predictor of location and severity of paravalvular regurgitation after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Koh, Ezra Y.; Lam, Kayan Y.; Bindraban, Navin R.; Cocchieri, Riccardo; Planken, R. Nils; Koch, Karel T.; Baan, Jan; de Mol, Bas A.; Marquering, Henk A.

    2015-01-01

    To determine whether the location of aortic valve calcium (AVC) influences the location of paravalvular regurgitation (PR). PR is an adverse effect of transcatheter aortic valve implantation (TAVI) with a negative effect on long-term patient survival. The relationship between AVC and the occurrence

  2. Aortic valve-sparing surgery in Marfan syndrome.

    Science.gov (United States)

    Nachum, Eyal; Shinfeld, Amichay; Kogan, Alexander; Preisman, Sergey; Levin, Shany; Raanani, Ehud

    2013-08-01

    Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain. Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 +/- 13 vs. 53 +/- 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients. While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (reaching 8 years with a mean of 34 +/- 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients. Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

  3. Osteoprotegerin inhibits aortic valve calcification and preserves valve function in hypercholesterolemic mice.

    Directory of Open Access Journals (Sweden)

    Robert M Weiss

    Full Text Available There are no rigorously confirmed effective medical therapies for calcific aortic stenosis. Hypercholesterolemic Ldlr (-/- Apob (100/100 mice develop calcific aortic stenosis and valvular cardiomyopathy in old age. Osteoprotegerin (OPG modulates calcification in bone and blood vessels, but its effect on valve calcification and valve function is not known.To determine the impact of pharmacologic treatment with OPG upon aortic valve calcification and valve function in aortic stenosis-prone hypercholesterolemic Ldlr (-/- Apob (100/100 mice.Young Ldlr (-/- Apob (100/100 mice (age 2 months were fed a Western diet and received exogenous OPG or vehicle (N = 12 each 3 times per week, until age 8 months. After echocardiographic evaluation of valve function, the aortic valve was evaluated histologically. Older Ldlr (-/- Apob (100/100 mice were fed a Western diet beginning at age 2 months. OPG or vehicle (N = 12 each was administered from 6 to 12 months of age, followed by echocardiographic evaluation of valve function, followed by histologic evaluation.In Young Ldlr (-/- Apob (100/100 mice, OPG significantly attenuated osteogenic transformation in the aortic valve, but did not affect lipid accumulation. In Older Ldlr (-/- Apob (100/100 mice, OPG attenuated accumulation of the osteoblast-specific matrix protein osteocalcin by ∼80%, and attenuated aortic valve calcification by ∼ 70%. OPG also attenuated impairment of aortic valve function.OPG attenuates pro-calcific processes in the aortic valve, and protects against impairment of aortic valve function in hypercholesterolemic aortic stenosis-prone Ldlr (-/- Apob (100/100 mice.

  4. A comparison of minimally invasive and standard aortic valve replacement.

    Science.gov (United States)

    Stoliński, Jarosław; Plicner, Dariusz; Grudzień, Grzegorz; Wąsowicz, Marcin; Musiał, Robert; Andres, Janusz; Kapelak, Bogusław

    2016-10-01

    The study objective was to compare aortic valve replacement through a right anterior minithoracotomy with aortic valve replacement through a median sternotomy. With propensity score matching, we selected 211 patients after aortic valve replacement through a right anterior minithoracotomy and 211 patients after aortic valve replacement who underwent operation between January 2010 and December 2013. Perioperative outcomes were analyzed, and multivariable logistic regression analysis of risk factors of postoperative morbidity was performed. For propensity score-matched patients, hospital mortality was 1.0% in the aortic valve replacement through a right anterior minithoracotomy group and 1.4% in the aortic valve replacement group (P = 1.000). Stroke occurred in 0.5% versus 1.4% (P = .615), myocardial infarction occurred in 1.4% versus 1.9% (P = 1.000), and new onset of atrial fibrillation occurred in 12.8% versus 24.2% (P = .003) of patients in the aortic valve replacement through a right anterior minithoracotomy and aortic valve replacement groups, respectively. Postoperative drainage was 353.5 ± 248.6 mL versus 544.3 ± 324.5 mL (P replacement through a right anterior minithoracotomy and aortic valve replacement groups, respectively. Mediastinitis occurred in 2.8% of patients after aortic valve replacement and in 0.0% of patients after aortic valve replacement through a right anterior minithoracotomy surgery (P = .040). Intensive care unit stay (1.3 ± 1.2 days vs 2.6 ± 2.6 days) and hospital stay (5.7 ± 1.6 days vs 8.7 ± 4.4 days) were statistically significantly shorter in the aortic valve replacement through a right anterior minithoracotomy group. Aortic valve replacement through a right anterior minithoracotomy surgery resulted in reduced postoperative morbidity (odds ratio, 0.4; P replacement through a right anterior minithoracotomy surgery resulted in a reduced infection rate, diminished postoperative bleeding and blood

  5. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  6. Futility, benefit, and transcatheter aortic valve replacement.

    Science.gov (United States)

    Lindman, Brian R; Alexander, Karen P; O'Gara, Patrick T; Afilalo, Jonathan

    2014-07-01

    Transcatheter aortic valve replacement (TAVR) is a transformative innovation that provides treatment for high or prohibitive surgical risk patients with symptomatic severe aortic stenosis who either were previously not referred for or were denied operative intervention. Trials have demonstrated improvements in survival and symptoms after TAVR versus medical therapy; however, there remains a sizable group of patients who die or lack improvement in quality of life soon after TAVR. This raises important questions about the need to identify and acknowledge the possibility of futility in some patients considered for TAVR. In this very elderly population, a number of factors in addition to traditional risk stratification need to be considered including multimorbidity, disability, frailty, and cognition in order to assess the anticipated benefit of TAVR. Consideration by a multidisciplinary heart valve team with broad areas of expertise is critical for assessing likely benefit from TAVR. Moreover, these complicated decisions should take place with clear communication around desired health outcomes on behalf of the patient and provider. The decision that treatment with TAVR is futile should include alternative plans to optimize the patient's health state or, in some cases, discussions related to end-of-life care. We review issues to be considered when making and communicating these difficult decisions. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Pregnancy Outcomes in Women With Aortic Valve Substitutes

    NARCIS (Netherlands)

    Heuvelman, Helena J.; Arabkhani, Bardia; Cornette, Jerome M. J.; Pieper, Petronella G.; Bogers, Ad J. J. C.; Takkenberg, Johanna J. M.; Roos-Hesselink, Jolien W.

    2013-01-01

    Young women who require aortic valve replacement need information on the potential cardiac and obstetric complications of pregnancy for the different valve substitutes available. We, therefore, assessed the pregnancy outcomes in women who had received an autograft, homograft, or mechanical valve in

  8. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  9. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation.

    Science.gov (United States)

    Koos, Ralf; Mahnken, Andreas Horst; Dohmen, Guido; Brehmer, Kathrin; Günther, Rolf W; Autschbach, Rüdiger; Marx, Nikolaus; Hoffmann, Rainer

    2011-07-15

    This study sought to examine a possible relationship between the severity of aortic valve calcification (AVC), the distribution of AVC and the degree of aortic valve regurgitation (AR) after transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS). 57 patients (22 men, 81 ± 5 years) with symptomatic AS and with a logistic EuroSCORE of 24 ± 12 were included. 38 patients (67%) received a third (18F)-generation CoreValve® aortic valve prosthesis, in 19 patients (33%) an Edwards SAPIEN™ prosthesis was implanted. Prior to TAVI dual-source computed tomography for assessment of AVC was performed. To determine the distribution of AVC the percentage of the calcium load of the most severely calcified cusp was calculated. After TAVI the degree of AR was determined by angiography and echocardiography. The severity of AR after TAVI was related to the severity and distribution of AVC. There was no association between the distribution of AVC and the degree of paravalvular AR after TAVI as assessed by angiography (r = -0.02, p = 0.88). Agatston AVC scores were significantly higher in patients with AR grade ≥ 3 (5055 ± 1753, n = 3) than in patients with AR grade AVC scores > 3000 were associated with a relevant paravalvular AR and showed a trend for increased need for second manoeuvres. There was a significant correlation between the severity of AVC and the degree of AR after AVR (r = 0.50, p AVC have an increased risk for a relevant AR after TAVI as well as a trend for increased need for additional procedures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  11. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  12. Clinical Implication of Aortic Wall Biopsy in Aortic Valve Disease with Bicuspid Valve Pathology

    Directory of Open Access Journals (Sweden)

    Yong Han Kim

    2016-12-01

    Full Text Available Background: Although unique aortic pathology related to bicuspid aortic valve (BAV has been previously reported, clinical implications of BAV to aortopathy risk have yet to be investigated. We looked for potential differences in matrix protein expressions in the aortic wall in BAV patients. Methods: Aorta specimens were obtained from 31 patients: BAV group (n=27, tricuspid aortic valve (TAV group (n=4. The BAV group was categorized into three subgroups: left coronary sinus-right coronary sinus (R+L group; n=13, 42%, right coronary sinus-non-coronary sinus (R+N group; n=8, 26%, and anteroposterior (AP group; n=6, 19%. We analyzed the expression of endothelial nitric oxide synthase (eNOS, matrix metalloproteinase (MMP-9, and tissue inhibitor of matrix metalloproteinase (TIMP-2. Results: Based on the mean value of the control group, BAV group showed decreased expression of eNOS in 72.7% of patients, increased MMP-9 in 82.3%, and decreased TIMP in 79.2%. There was a higher tendency for aortopathy in the BAV group: eNOS (BAV:TAV= 53%±7%:57%±11%, MMP-9 (BAV:TAV=48%±10%:38%±1%. The AP group showed lower expression of eNOS than the fusion (R+L, R+N group did; 48%±5% vs. 55%±7% (p=0.081. Conclusion: Not all patients with BAV had expression of aortopathy; however, for patients who had a suspicious form of bicuspid valve, aortic wall biopsy could be valuable to signify the presence of aortopathy.

  13. [Unicuspid Aortic Valve Stenosis Combined with Aortic Coarctation;Report of a Case].

    Science.gov (United States)

    Kubota, Takehiro; Wakasa, Satoru; Shingu, Yasushige; Matsui, Yoshiro

    2016-06-01

    Unicuspid aortic valve in an adult is extremely rare. In addition, 90% of the patients with aortic coarctation are reported to die before the age 50. A 60-year-old woman was admitted to our hospital for further examination of exertional dyspnea which had begun one year before. She had been under medical treatment for hypertension since early thirties, and had been also diagnosed with moderate aortic stenosis at 50 years of age. She was at 1st diagnosed with aortic coarctation combined with bicuspid aortic valve stenosis. The aortic valve was then found unicuspid and was replaced under cardiopulmonary bypass with perfusion to both the ascending aorta and the femoral artery. Repair of aortic coarctation was performed 3 months later through left thoracotomy without extracorporeal circulation due to the rich collateral circulation. She had no postoperative complications, and hypertension as well as ankle-brachial index improved to the normal levels.

  14. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  15. Transcatheter aortic valve implantation for a failed bio-bentall in patients with Marfan syndrome.

    Science.gov (United States)

    Beigel, Roy; Siegel, Robert J; Kahlon, Ravi S; Jilaihawi, Hasan; Cheng, Wen; Makkar, Raj R

    2014-01-01

    Patients with Marfan syndrome are at risk for ascending aortic dilation and dissection at the level of the aortic sinuses, making aortic root and valve replacement common. Patients undergoing an aortic root replacement with concomitant replacement of the aortic valve with a bioprosthesis (Bio-Bentall) are predisposed to bioprosthesis failure. Transcatheter aortic valve implantation (TAVI) has become an option for aortic valve replacement, avoiding cardiopulmonary bypass and/or median sternotomy. We present the first 2 reported patients with Marfan syndrome who underwent a valve-in-valve TAVI in the setting of a prior Bio-Bentall. © 2014 S. Karger AG, Basel.

  16. Autopsy after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    van Kesteren, F; Wiegerinck, E M A; Rizzo, S

    2017-01-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview...... of the autopsy findings in patients with TAVI in their medical history divided by the timing of death with specific interest in the added value of autopsy over a solely clinically determined cause of death. In 8 European centres, 72 cases with autopsy reports were available. Autopsies were divided according...... (22.6%) and respiratory failure (9.7%). Of the nine patients with death >30 days, 88.9% died of sepsis, caused by infective endocarditis in half of them. At total of 12 patients revealed cerebrovascular complications. Autopsy revealed unexpected findings in 61.1% and resulted in a partly or completely...

  17. Midterm Results of Aortic Valve Replacement with Cryopreserved Homografts

    Directory of Open Access Journals (Sweden)

    Emre Özker

    2012-06-01

    Full Text Available Objective: The aim of this study was to analyze the midterm clinical results of aortic valve replacement with cryopreserved homografts.Materials and Methods: Aortic valve replacement was performed in 40 patients with cryopreserved homograft. The indications were aortic valve endocarditis in 20 patients (50%, truncus arteriosus in 6 patients (15%, and re-stenosis or regurtitation after aortic valve reconstruction in 14 (35% patients. The valve sizes ranged from 10 to 27mm. A full root replacement technique was used for homograft replacement in all patients.Results: The 30-day postoperative mortality rate was 12.5% (5 patients. There were four late deaths. Only one of them was related to cardiac events. Overall mortality was 22.5%. Thirty-three patients were followed up for 67±26 months. Two patients needed reoperation due to aortic aneurysm caused by endocarditis. The mean transvalvular gradient significantly decreased after valve replacement (p<0.003. The last follow up showed that the 27 (82% patients had a normal left ventricular function.Conclusion: Cryopreserved homografts are safe alternatives to mechanical valves that can be used when there are proper indications. Although it has a high perioperative mortality rate, cryopreserved homograft implantation is an alternative for valve replacement, particularly in younger patients and for complex surgical problems such as endocarditis that must be minimalized.

  18. Choice of Treatment for Aortic Valve Stenosis in the Era of Transcatheter Aortic Valve Replacement in Eastern Denmark (2005 to 2015)

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Olsen, Niels T

    2016-01-01

    OBJECTIVES: The aim of this study was to evaluate the choice of treatment for severe aortic valve stenosis in the era of transcatheter aortic valve replacement (TAVR) in Eastern Denmark. BACKGROUND: Until the early 21st century, the only therapeutic option for aortic valve stenosis was surgical a...

  19. Large aortic root pseudoaneurysm occurring late after aortic root repair and valve replacement for endocarditis

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2013-01-01

    Full Text Available A 68-year-old male presented with Group B Streptococcus aortic valve (AV endocarditis with aortic root abscess and refractory sepsis. An emergency cardiac surgery was performed with root abscess drainage, excision and debridement of necrotic tissue, reconstruction of annulus, and AV replacement. Fifteen months later he presented with a huge aortic root pseudoaneurysm (PA. This case illustrates late occurrence of aortic root PA following AV surgery for endocarditis.

  20. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  1. Outcomes of Aortic Valve-Sparing Operations in Marfan Syndrome.

    Science.gov (United States)

    David, Tirone E; David, Carolyn M; Manlhiot, Cedric; Colman, Jack; Crean, Andrew M; Bradley, Timothy

    2015-09-29

    In many cardiac units, aortic valve-sparing operations have become the preferred surgical procedure to treat aortic root aneurysm in patients with Marfan syndrome, based on relatively short-term outcomes. This study examined the long-term outcomes of aortic valve-sparing operations in patients with Marfan syndrome. All patients with Marfan syndrome operated on for aortic root aneurysm from 1988 through 2012 were followed prospectively for a median of 10 years. Follow-up was 100% complete. Time-to-event analyses were calculated using the Kaplan-Meier method with log-rank test for comparisons. A total of 146 patients with Marfan syndrome had aortic valve-sparing operations. Reimplantation of the aortic valve was performed in 121 and remodeling of the aortic root was performed in 25 patients. Mean age was 35.7 ± 11.4 years and two-thirds were men. Nine patients had acute, 2 had chronic type A, and 3 had chronic type B aortic dissections before surgery. There were 1 operative and 6 late deaths, 5 caused by complications of dissections. Mortality rate at 15 years was 6.8 ± 2.9%, higher than the general population matched for age and sex. Five patients required reoperation on the aortic valve: 2 for endocarditis and 3 for aortic insufficiency. Three patients developed severe, 4 moderate, and 3 mild-to-moderate aortic insufficiency. Rate of aortic insufficiency at 15 years was 7.9 ± 3.3%, lower after reimplantation than remodeling. Nine patients developed new distal aortic dissections during follow-up. Rate of dissection at 15 years was 16.5 ± 3.4%. Aortic valve-sparing operations in patients with Marfan syndrome were associated with low rates of valve-related complications in long-term follow-up. Residual and new aortic dissections were the leading cause of death. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Outcomes for Low-Risk Surgical Aortic Valve Replacement: A Benchmark for Aortic Valve Technology.

    Science.gov (United States)

    Johnston, Lily E; Downs, Emily A; Hawkins, Robert B; Quader, Mohammed A; Speir, Alan M; Rich, Jeffrey B; Ghanta, Ravi K; Yarboro, Leora T; Ailawadi, Gorav

    2017-10-01

    Two large, randomized trials are underway evaluating transcatheter aortic valve replacement (AVR) against conventional surgical AVR. We analyzed contemporary, real-world outcomes of surgical AVR in low-risk patients to provide a practical benchmark of outcomes and cost for evaluating current and future transapical AVR technology. From 2010 to 2015, 2,505 isolated AVR operations were performed for severe aortic stenosis at 18 statewide cardiac institutions. Of these, 2,138 patients had a Society of Thoracic Surgeons predicted risk of mortality of less than 4%, and 1,119 met other clinical and hemodynamic criteria as outlined in the PARTNER 3 (The Placement of Transcatheter Aortic Valves) protocol. Patients with endocarditis, end-stage renal disease, ejection fraction of less than 0.45, bicuspid valves, and previous valve replacements were excluded. Outcomes of interest included operative death and postoperative adverse events. The median Society of Thoracic Surgeons predicted risk of mortality for the study-eligible patients was 1.44%, with a median age of 72 years (interquartile range [IQR], 65 to 78 years). Operative mortality was 1.3%, permanent stroke was 1.3%, and pacemaker requirement was 4.2%. The most common adverse events were transfusion of 2 or more units of red blood cells (18%) and atrial fibrillation (28%). The median length of stay was 6 days (IQR, 5 to 8 days). Median total hospital cost was $37,999 (IQR, $30,671 to $46,138). Examination of complications by age younger than 65 vs 65 or older demonstrated a significantly lower need for transfusion (11.2%, p risk patients undergoing surgical AVR in the current era have excellent results. The most common complications were atrial fibrillation and bleeding. These real-world results should provide additional context for upcoming transcatheter clinical trial data. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. The living aortic valve: From molecules to function

    Science.gov (United States)

    Chester, Adrian H.; El-Hamamsy, Ismail; Butcher, Jonathan T.; Latif, Najma; Bertazzo, Sergio; Yacoub, Magdi H.

    2014-01-01

    The aortic valve lies in a unique hemodynamic environment, one characterized by a range of stresses (shear stress, bending forces, loading forces and strain) that vary in intensity and direction throughout the cardiac cycle. Yet, despite its changing environment, the aortic valve opens and closes over 100,000 times a day and, in the majority of human beings, will function normally over a lifespan of 70–90 years. Until relatively recently heart valves were considered passive structures that play no active role in the functioning of a valve, or in the maintenance of its integrity and durability. However, through clinical experience and basic research the aortic valve can now be characterized as a living, dynamic organ with the capacity to adapt to its complex mechanical and biomechanical environment through active and passive communication between its constituent parts. The clinical relevance of a living valve substitute in patients requiring aortic valve replacement has been confirmed. This highlights the importance of using tissue engineering to develop heart valve substitutes containing living cells which have the ability to assume the complex functioning of the native valve. PMID:25054122

  4. Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Ju [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Shin, Je Kyoun; Chee, Hyun Kun; Kim, Jun Suk [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Ko, Sung Min [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2015-07-15

    To characterize aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve (BAV) morphology using computed tomography (CT) and surgical findings. We retrospectively enrolled 209 patients with BAVs who underwent transthoracic echocardiography (TTE) and CT. BAVs were classified as anterior-posterior (BAV-AP) or lateral (BAV-LA) orientation of the cusps and divided according to the presence (raphe+) or absence (raphe-) of a raphe. Ascending aortic dimensions were measured by CT at four levels. BAV-AP was present in 129 patients (61.7 %) and raphe+ in 120 (57.4 %). Sixty-nine patients (33.0 %) had aortic regurgitation (AR), 70 (33.5 %) had aortic stenosis (AS), and 58 (27.8 %) had combined AS and AR. AR was more common in patients with BAV-AP and raphe+; AS was more common with BAV-LA and raphe-.Annulus/body surface area and tubular portion/body surface area diameters in patients with BAV-AP (17.1 ± 2.3 mm/m{sup 2} and 24.2 ± 5.3 mm/m{sup 2}, respectively) and raphe+ (17.3 ± 2.2 mm/m{sup 2} and 24.2 ± 5.5 mm/m{sup 2}, respectively) were significantly different from those with BAV-LA (15.8 ± 1.9 mm/m{sup 2} and 26.4 ± 5.5 mm/m{sup 2}, respectively) and raphe- (15.7 ± 1.9 mm/m{sup 2} and 26.2 ± 5.4 mm/m{sup 2}, respectively). The morphological characteristics of BAV might be associated with the type of valvular dysfunction, and degree and location of an ascending aorta dilatation. (orig.)

  5. Imaging of aortic valve dynamics in 4D OCT

    Directory of Open Access Journals (Sweden)

    Schnabel Christian

    2015-09-01

    Full Text Available The mechanical components of the heart, especially the valves and leaflets, are enormous stressed during lifetime. Therefore, those structures undergo different pathophysiological tissue transformations which affect cardiac output and in consequence living comfort of affected patients. These changes may lead to calcific aortic valve stenosis (AVS, the major heart valve disease in humans. The knowledge about changes of the dynamic behaviour during the course of this disease and the possibility of early stage diagnosis is of particular interest and could lead to the development of new treatment strategies and drug based options of prevention or therapy. 4D optical coherence tomography (OCT in combination with high-speed video microscopy were applied to characterize dynamic behaviour of the murine aortic valve and to characterize dynamic properties during artificial stimulation. We present a promising tool to investigate the aortic valve dynamics in an ex vivo disease model with a high spatial and temporal resolution using a multimodal imaging setup.

  6. First transcatheter aortic valve implantation for severe pure aortic regurgitation in Asia

    Science.gov (United States)

    Chiam, Paul Toon-Lim; Ewe, See Hooi; Chua, Yeow Leng; Lim, Yean Teng

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) has become the standard of care for inoperable patients with symptomatic severe aortic stenosis (AS), and an alternative to open aortic valve replacement for patients at high surgical risk. TAVI has also been performed in several groups of patients with off-label indications such as severe bicuspid AS, and as a valve-in-valve therapy for a degenerated surgical bioprosthesis. Although TAVI with CoreValve® prosthesis is technically challenging, and global experience in the procedure is limited, the procedure could be a treatment option for well-selected patients with severe pure aortic regurgitation (AR). Herein, we report Asia's first case of TAVI for severe pure AR in a patient who was at extreme surgical risk, with good clinical outcome at six months. PMID:24570320

  7. Knowledge of native valve anatomy is essential in follow-up of patients after aortic valve replacement

    NARCIS (Netherlands)

    Cozijnsen, Luc; van der Zaag-Loonen, Hester J.; Cozijnsen, Martinus A.; Braam, Richard L.; Heijmen, Robin H.; Mulder, Barbara J. M.

    2016-01-01

    Background: After aortic valve replacement (AVR), bicuspid aortic valve (BAV) patients continue to be at risk of aortic complications. Therefore, knowledge of native valve anatomy is important for follow-up. We aimed to determine the extent of which the presence of BAV disease is known in a regional

  8. Transcatheter Aortic Valve Replacement Versus Aortic Valve Bypass: A Comparison of Outcomes and Economics.

    Science.gov (United States)

    Brown, John W; Boyd, Jack H; Patel, Parth M; Baker, Mary L; Syed, Amjad; Ladowski, Joe; Corvera, Joel

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is currently offered to patients who are high-risk candidates for conventional surgical aortic valve replacement. For the past 37 years, off-pump aortic valve bypass (AVB) has been used in elderly patients at our center for this similarly high-risk group. Although TAVR and AVB were offered to similar patients at our center, comparisons of clinical outcomes and hospital economics for each strategy were not reported. We reviewed the clinical and financial records of 53 consecutive AVB procedures performed since 2008 with the records of 51 consecutive TAVR procedures performed since 2012. Data included demographics, hemodynamics, The Society of Thoracic Surgeons (STS) risk score, extent of coronary disease, and ventricular function. Follow-up was 100% in both groups. Hospital financial information for both cohorts was obtained. Mean risk score for the TAVR group was 10.1% versus 17.6% for AVB group (p < 0.001). Kaplan-Meier hospital rates of 3- and 6-month survival and of 1-year survival were 88%, 86%, 81%, and 61% and 89%, 83%, 83%, and 70% for the TAVR and AVB groups, respectively (p = 0.781). Two patients who had undergone TAVR had a procedure-related stroke. The one stroke in an AVB recipient was late and not procedure related. At discharge, mild and moderate perivalvular and central aortic insufficiency were present in 31% and 16% of TAVR recipients, respectively; no AVB valve leaked. Transvalvular gradients were reduced to less than 10 mm Hg in both groups. The average hospital length of stay for the AVB-treated patients was 13 days, and it was 9 days for the TAVR-treated patients. Median hospital charges were $253,000 for TAVR and $158,000 for AVB. Mean payment to the hospital was $65,000 (TAVR) versus $64,000 (AVB), and the mean positive contribution margin (profit) to the hospital was $14,000 for TAVR versus $29,000 for AVB. TAVR and AVB relieve aortic stenosis and have similar and acceptable procedural mortality

  9. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...

  10. Aortic valve sparing root surgery for Marfan syndrome.

    Science.gov (United States)

    Matalanis, George; Perera, Nisal K

    2017-11-01

    Aortic valve sparing root surgery (AVSRS) is a safe and durable alternative for patients with dilated roots or pure aortic regurgitation (AR), which avoids the risks of anticoagulation or valvular degeneration with prosthetic valves. Notwithstanding the theoretical challenges of greater tissue fragility in Marfan syndrome (MFS), AVSRS has been demonstrated to have equal outcomes in this condition as it does in those without MFS. The benefits of retaining the native aortic valve in this generally younger age group extend beyond those of avoiding the inconvenience and complications of prolonged exposure to anticoagulants and include ease of management for future aortic, cardiac and non-cardiac procedures which are the norm for these patients. The essential principles of AVSRS in MFS do not differ from those for the rest of the population. Successful repair and durable valve function depend on a sound understanding of the close interaction between the structure and function of this exquisitely designed piece of engineering. We are fortunate to have numerous tools in our surgical armamentarium to preserve these valves. It is the purpose of this paper to demystify the complex structure-function interactions of the aortic valve, thereby gaining an intuition for AVSRS. We will also elaborate on specific technical details of established techniques that we have found successful in preserving the normal function of these valves in the long term.

  11. Neurotrophin 3 upregulates proliferation and collagen production in human aortic valve interstitial cells: a potential role in aortic valve sclerosis.

    Science.gov (United States)

    Yao, Qingzhou; Song, Rui; Ao, Lihua; Cleveland, Joseph C; Fullerton, David A; Meng, Xianzhong

    2017-06-01

    Calcific aortic valve disease (CAVD) is a leading cardiovascular disorder in the elderly. Diseased aortic valves are characterized by sclerosis (fibrosis) and nodular calcification. Sclerosis, an early pathological change, is caused by aortic valve interstitial cell (AVIC) proliferation and overproduction of extracellular matrix (ECM) proteins. However, the mechanism of aortic valve sclerosis remains unclear. Recently, we observed that diseased human aortic valves overexpress growth factor neurotrophin 3 (NT3). In the present study, we tested the hypothesis that NT3 is a profibrogenic factor to human AVICs. AVICs isolated from normal human aortic valves were cultured in M199 growth medium and treated with recombinant human NT3 (0.10 µg/ml). An exposure to NT3 induced AVIC proliferation, upregulated the production of collagen and matrix metalloproteinase (MMP), and augmented collagen deposition. These changes were abolished by inhibition of the Trk receptors. NT3 induced Akt phosphorylation and increased cyclin D1 protein levels in a Trk receptor-dependent fashion. Inhibition of Akt abrogated the effect of NT3 on cyclin D1 production. Furthermore, inhibition of either Akt or cyclin D1 suppressed NT3-induced cellular proliferation and MMP-9 and collagen production, as well as collagen deposition. Thus, NT3 upregulates cellular proliferation, ECM protein production, and collagen deposition in human AVICs. It exerts these effects through the Trk-Akt-cyclin D1 cascade. NT3 is a profibrogenic mediator in human aortic valve, and overproduction of NT3 by aortic valve tissue may contribute to the mechanism of valvular sclerosis. Copyright © 2017 the American Physiological Society.

  12. Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis.

    Science.gov (United States)

    Buellesfeld, Lutz; Gerckens, Ulrich; Grube, Eberhard

    2008-04-01

    Percutaneous aortic valve replacement is a new less-invasive alternative for high-risk surgical candidates with aortic stenosis. However, the clinical experience is still limited, and the currently available 'first-generation devices' revealed technical shortcomings, such as lack of repositionability and presence of paravalvular leakages. We report the first-in-man experience with the new self-expanding Lotus Valve prosthesis composed of a nitinol frame with implemented bovine pericardial leaflets which is designed to address these issues, being repositionable and covered by a flexible membrane to seal paravalvular gaps. We implanted this prosthesis in a 93-year old patient presenting with severe symptomatic aortic stenosis (valve area: 0.6 cm(2)). Surgical valve replacement had been declined due to comorbidities. We used a retrograde approach for insertion of the 21-French Lotus catheter loaded with the valve prosthesis via surgical cut-down to the external iliac artery. Positioning of the valve was guided by transesophageal echo and supra-aortic angiograms. The prosthesis was successfully inserted and deployed within the calcified native valve. Echocardiography immediately after device deployment showed a significant reduction of the transaortic mean pressure gradient (32 to 9 mmHg; final valve area 1.7 cm(2)) without evidence of residual aortic regurgitation. The postprocedural clinical status improved from NYHA-IV to NYHA-II. These results remained unchanged up to the 3 month follow-up. Successful percutaneous aortic valve replacement can be performed using the new self-expanding and repositionable Lotus valve for treatment of high-risk patients with aortic valve stenosis. Further studies are mandatory to assess device safety and efficacy in larger patient populations. Copyright 2008 Wiley-Liss, Inc.

  13. Survival and freedom from aortic valve-related reoperation after valve-sparing aortic root replacement in 1015 patients.

    Science.gov (United States)

    Kari, Fabian A; Doll, Kai-Nicolas; Hemmer, Wolfgang; Liebrich, Markus; Sievers, Hans-Hinrich; Richardt, Doreen; Reichenspurner, Hermann; Detter, Christian; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2016-04-01

    The aim of this study was to characterize mortality and aortic valve replacement after valve-sparing aortic root replacement (V-SARR) in a multicentre cohort. Between 1994 and 2014, 1015 patients had V-SARR with (n = 288, 28%) or without cusp/commissure repair (n = 727, 72%) at the centres of Lübeck (n = 343, 34%), Stuttgart (n = 346, 34%), Hamburg (n = 109, 11%) and Freiburg (n = 217, 21%), Germany. Comparative survival of an age- and gender-matched general population was calculated. Log-rank tests and multiple logistic regression were used to identify risk factors. The mean follow-up was 5.2 ± 3.9 years. Cumulative follow-up comprised 2933 patient-years. Early survival was 98%. NYHA status and aneurysm size were predictive of death during mid-term follow-up (P = 0.025). Freedom from aortic valve replacement was 90% at 8 years, with the type of V-SARR (root remodelling, David II) being a risk factor (P = 0.015). Bicuspid aortic valve (P = 0.26) and initial valve function (P = 0.4) did not impact reoperation. The need of additional valve repair (cusps/commissures) was not linked to reoperation: freedom from aortic valve replacement at 8 years was 84% if cusp repair was performed versus 90% if V-SARR alone was performed (P = 0.218). Marfan syndrome had no impact on survival or on aortic valve replacement. Mid-term survival of patients after V-SARR is comparable with that of a matched general population. The regurgitant bicuspid aortic valve is a favourable substrate for V-SARR. Prophylactic surgery should be performed before symptoms or large aneurysms are present to achieve optimal mid-term outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  15. Characterization of Aortic Valve Closure Artifact During Outflow Tract Mapping: Correlation With Hemodynamics and Mechanical Valves.

    Science.gov (United States)

    Romero, Jorge; Ajijola, Olujimi; Shivkumar, Kalyanam; Tung, Roderick

    2017-06-01

    Premature ventricular contractions originating in the left ventricle outflow tract represent a significant subgroup of patients referred for catheter ablation. Mechanical artifacts from aortic valve leaflet motion may be observed during mapping, although the incidence and characteristics have not been reported. Twenty-eight consecutive patients with left ventricle outflow tract premature ventricular contraction were included. Electric signals recorded on the ablation catheter not coincident with atrial or ventricular depolarization were analyzed on the recording system. Correlation with invasive hemodynamic aortic pressure tracings was performed. Additionally, 4 patients with mechanical aortic valves, who underwent scar-related ventricular tachycardia ablation, were analyzed to correlate the timing of the observed artifacts with native aortic valves. Aortic valve artifact was observed while mapping within the coronary cusps in 11 patients (39%; 73% men; age, 41±25 years; left ventricular ejection fraction 49±16%) with high incidence from the left coronary cusp. This artifact was consistently observed with timing coincident with the terminal portion of the T wave. The average interval between the end of the T wave and the aortic valve artifact was 19±37 ms. The duration of the aortic valve artifact was 39±8 ms with amplitude of 0.12±0.07 mV (range, 0.06-0.36 mV). In patients referred for left ventricle outflow tract premature ventricular contraction ablation, an aortic valve closure artifact is observed in up to one third of cases during mapping within the aortic cusps. The timing of this artifact correlates with invasive hemodynamics and mechanical aortic valve artifacts. Recognition of this physiological phenomenon is useful when assigning near-field activation. © 2017 American Heart Association, Inc.

  16. Transcatheter aortic valve implantation in the elderly: who to refer?

    Science.gov (United States)

    Finn, Matthew; Green, Philip

    2014-01-01

    In recent years, experience with transcatheter aortic valve implantation has led to improved outcomes in elderly patients with severe aortic stenosis (AS) who may not have previously been considered for intervention. These patients are often frail with significant comorbid conditions. As the prevalence of AS increases, there is a need for improved assessment parameters to determine the patients most likely to benefit from this novel procedure. This review discusses the diagnostic criteria for severe AS and the trials available to aid in the decision to refer for aortic valve procedures in the elderly. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. [Aortic valve preservation in Marfan syndrome. Initial experience].

    Science.gov (United States)

    Forteza, Alberto; Cortina, Jose M; Sánchez, Violeta; Centeno, Jorge; López, M Jesús; Pérez de la Sota, Enrique; Rufilanchas, Juan J

    2007-05-01

    Preservation of the aortic valve using the technique described by David has been shown to be as effective as the Bentall-De Bono procedure. It avoids both the need for long-term anticoagulation and the complications associated with mechanical prostheses. We report our initial experience using this technique in patients with Marfan syndrome. Between April 2004 and April 2006, we used the David reimplantation technique in 40 patients with an aortic root aneurysm. Eighteen patients had Marfan syndrome. Their median age was 29 years (13-55 years). Echocardiography showed that the median diameter of the aortic sinus was 53 mm (46-59 mm). In 17 patients, aortic valve preservation was possible. No patient died during hospitalization and there were no significant complications. On echocardiography at discharge, no patient had greater than grade-II aortic regurgitation. During a median follow-up period of 8 months (1-24 months), one patient died due to rupture of an abdominal aneurysm. The others are all in New York Heart Association class I. Preservation of the aortic valve by means of valve reimplantation produced excellent results. It avoided both the thromboembolic and hemorrhagic complications associated with prostheses and the need for long-term anticoagulation. If reimplanted valves continue to function adequately over the long term, this technique should become the treatment of choice for aneurysms of the ascending aorta in patients with Marfan syndrome.

  18. Safety considerations during transapical aortic valve implantation.

    Science.gov (United States)

    Drews, Thorsten; Pasic, Miralem; Juran, Ralf; Unbehaun, Axel; Dreysse, Stephan; Kukucka, Marian; Mladenow, Alexander; Hetzer, Roland; Buz, Semih

    2014-05-01

    Transcatheter aortic valve implantation (TAVI) is a new method for the treatment of very high-risk patients with aortic valve stenosis. The radiation dose to which the patient and each member of the heart team are exposed during this new fluoroscopically guided intervention is unknown. Between April 2008 and August 2013, 1177 consecutive patients underwent transapical TAVI (TA-TAVI). In 22 consecutive patients undergoing TA-TAVI, the radiation doses to the cardiothoracic surgeon, cardiologist, anaesthesiologist (performing echocardiography examination), surgical assistant and nurse were measured. The radiation dose measurements were performed during TAVI using thermoluminescence and film dosimeters positioned on seven parts of the body: (i) chest above the lead apron, (ii) pelvic area below the apron, (iii) chest below the apron, (iv) thyroid gland above the apron, (v) near eyes, (vi) hands (using rings) and (vii) the feet. The results were compared with the values given in the international literature on recommended radiation dose limits for workers. The mean radiation time was 6.1 min and the mean dose-area product for the patients was 8.661 µGy · m(2). Analysis of the dosimeters and the calculation of the effective dose showed a per intervention dose of 0.03 mSv for the surgeon, 0.05 mSv for the assistant, 0.02 mSv for the cardiologist and the anaesthesiologist and 0.001 mSv for the nurse. The maximum ionizing radiation per intervention was 0.5 mSv at the right hand of the surgeon (holding the introducer sheet) and 0.7 mSv at the left hand of the surgical assistant. Additionally, the analysis of the body dose shows a maximum dose to the lower leg of the surgeon (0.3 mSv) and the genital area of the assistant (0.06 mSv). During a TA-TAVI procedure, the patients receive a higher X-ray dose than during coronary angiography with intervention. After 100 TAVI procedures, the members of the heart team sustain a comparable dose of ionizing radiation to the annual dose

  19. Aortic root reimplantation procedure: a new milestone in aortic valve-sparing operations

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-08-01

    Full Text Available Aim: Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.Methods: 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60 months. The average age of patients was 57±13 (23-73 years 56±13 years.Results: The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2. Long-term follow-up revealed no valve-associated complications.Conclusion: The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.Key words: aortic aneurysm; aortic valve; valve-sparing operations.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  20. Pros and cons of transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  1. [Valve-sparing Replacement in Patients with Aortic Root Dilatation].

    Science.gov (United States)

    Yamazaki, Kazuhiro; Minatoya, Kenji; Ueda, Ryoma; Takehara, Masato; Sakamoto, Kazuhisa; Ide, Yujiro; Kanemitsu, Hideo; Ueyama, Koji; Ikeda, Tadashi

    2018-01-01

    Valve-sparing root replacement is increasingly used to overcome drawbacks associated with valvular prostheses. In our institution, 7 patients underwent valve-sparing root replacement from August 2016 to July 2017. The mean age was 45 years (range, 14~69 years). Three patients had Marfan syndrome and 1 had Loeys-Dietz syndrome with acute aortic dissection. All patients underwent surgery with reimplantation technique using a Valsalva graft. Two patients required repair of aortic valve leaflet prolapse. All patients had an excellent clinical course, with mild or no aortic regurgitation and a decrease in end-diastolic volume on echocardiography. These results support the continued use of valve-sparing root replacement in selected patients.

  2. Aortic false aneurysm after double valve replacement in a child.

    Science.gov (United States)

    Kobayashi, Daisuke; Walters, Henry L; Forbes, Thomas J; Aggarwal, Sanjeev

    2013-06-01

    Aortic false aneurysm (AFA) is a rare but life threatening complication after aortic surgery. We report a 13-year-old boy who developed AFA after double valve replacement consisting of the following: (1) Bentall procedure utilizing a 25-mm St. Jude aortic valved composite Hemashield Dacron graft (Meadox Medicals, Oakland, NJ); and (2) replacement of right ventricle to pulmonary artery conduit with a 25-mm porcine valved conduit. The exterior metal ring of the pulmonary prosthetic valve conduit caused an abrasion of the Hemashield graft, resulting in the AFA. In addition to simple suture repair, the pulmonary conduit was wrapped with a Gore-Tex patch (W.L. Gore Assoc, Flagstaff, AZ) to prevent recurrence. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Paravalvar leak of aortic valve replacement and/or mitral valve replacement: diagnosis of electron beam computed tomography

    International Nuclear Information System (INIS)

    Zhi Aihua; Dai Ruping; Jiang Shiliang; Cao Cheng; Qi Xiaoou; Bai Hua; Chen Yao; Duan Xiufang

    2005-01-01

    Objective: To evaluate the periprothetic leak in aortic valve replacement and/or mitral valve replacement on electron beam CT. Methods: A retrospective study was performed in 121 patients who underwent electron beam CT between 2002 and 2004. 102 patients underwent aortic valve replacement, 12 patients underwent mitral valve replacement, and 7 patients underwent double valve replacement. Paravalvar leak was estimated by electron beam CT. Results: In 121 patients after the aortic valve replacement and/or mitral valve replacement, 7 patients were diagnosed as trifle aortic paravalvar leak, 3 patients as moderate aortic paravalvar leak, and 4 patients as mass aortic paravalvar leak on electron beam CT. 1 patients were diagnosed as trifle mitral paravalvar leak on electron beam CT. Conclusion: Electron beam CT is a very useful method in detecting paravalvar leak after valve replacement and for follow-up. (authors)

  4. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  5. Systematic review of the outcome of aortic valve replacement in patients with aortic stenosis

    NARCIS (Netherlands)

    Sharma, Umesh C.; Barenbrug, Paul; Pokharel, Saraswati; Dassen, Willem R. M.; Pinto, Yigal M.; Maessen, Jos G.

    2004-01-01

    BACKGROUND: After the establishment of aortic valve replacement procedure for aortic stenosis, there are heterogeneous studies and varying reports on outcome. An analysis that compares individual studies to summarize the overall effect is still lacking. This study systematically analyzes the change

  6. Effect of candesartan treatment on left ventricular remodeling after aortic valve replacement for aortic stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbaek, Lars; Poulsen, Mikael K

    2010-01-01

    In hypertension, angiotensin receptor blockers can augment regression of left ventricular (LV) hypertrophy. It is not known whether this also is the case after aortic valve replacement (AVR) for severe aortic stenosis (AS). To test the hypothesis that treatment with candesartan in addition...

  7. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    Science.gov (United States)

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  8. Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

    Science.gov (United States)

    Schnell, Susanne; Smith, Danielle A; Barker, Alex J; Entezari, Pegah; Honarmand, Amir R; Carr, Maria L; Malaisrie, S Chris; McCarthy, Patrick M; Collins, Jeremy; Carr, James C; Markl, Michael

    2016-11-01

    Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology. Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives. BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  9. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  10. A planning system for transapical aortic valve implantation

    Science.gov (United States)

    Gessat, Michael; Merk, Denis R.; Falk, Volkmar; Walther, Thomas; Jacobs, Stefan; Nöttling, Alois; Burgert, Oliver

    2009-02-01

    Stenosis of the aortic valve is a common cardiac disease. It is usually corrected surgically by replacing the valve with a mechanical or biological prosthesis. Transapical aortic valve implantation is an experimental minimally invasive surgical technique that is applied to patients with high operative risk to avoid pulmonary arrest. A stented biological prosthesis is mounted on a catheter. Through small incisions in the fifth intercostal space and the apex of the heart, the catheter is positioned under flouroscopy in the aortic root. The stent is expanded and unfolds the valve which is thereby implanted into the aortic root. Exact targeting is crucial, since major complications can arise from a misplaced valve. Planning software for the perioperative use is presented that allows for selection of the best fitting implant and calculation of the safe target area for that implant. The software uses contrast enhanced perioperative DynaCT images acquired under rapid pacing. In a semiautomatic process, a surface segmentation of the aortic root is created. User selected anatomical landmarks are used to calculate the geometric constraints for the size and position of the implant. The software is integrated into a PACS network based on DICOM communication to query and receive the images and implants templates from a PACS server. The planning results can be exported to the same server and from there can be rertieved by an intraoperative catheter guidance device.

  11. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. Adjusting parameters of aortic valve stenosis severity by body size

    DEFF Research Database (Denmark)

    Minners, Jan; Gohlke-Baerwolf, Christa; Kaufmann, Beat A

    2014-01-01

    BACKGROUND: Adjustment of cardiac dimensions by measures of body size appears intuitively convincing and in patients with aortic stenosis, aortic valve area (AVA) is commonly adjusted by body surface area (BSA). However, there is little evidence to support such an approach. OBJECTIVE: To identify...... the adequate measure of body size for the adjustment of aortic stenosis severity. METHODS: Parameters of aortic stenosis severity (jet velocity, mean pressure gradient (MPG) and AVA) and measures of body size (height, weight, BSA and body mass index (BMI)) were analysed in 2843 consecutive patients with aortic...... stenosis (jet velocity ≥2.5 m/s) and related to outcomes in a second cohort of 1525 patients from the Simvastatin/Ezetimibe in Aortic Stenosis (SEAS) study. RESULTS: Whereas jet velocity and MPG were independent of body size, AVA was significantly correlated with height, weight, BSA and BMI (Pearson...

  13. Evaluation of a porcine model of early aortic valve sclerosis.

    Science.gov (United States)

    Sider, Krista L; Zhu, Cuilan; Kwong, Andrea V; Mirzaei, Zahra; de Langé, Cornelius F M; Simmons, Craig A

    2014-01-01

    Calcific aortic valve disease (CAVD) is associated with significant cardiovascular morbidity. While late-stage CAVD is well-described, early pathobiological processes are poorly understood due to the lack of animal models that faithfully replicate early human disease. Here we evaluated a hypercholesterolemic porcine model of early diet-induced aortic valve sclerosis. Yorkshire swine were fed either a standard or high-fat/high-cholesterol diet for 2 or 5 months. Right coronary aortic valve leaflets were excised and analyzed (immuno)histochemically. Early human-like proteoglycan-rich onlays formed between the endothelial layer and elastic lamina in the fibrosa layer of valve leaflets, with accelerated formation associated with hypercholesterolemia (Psclerosis in hypercholesterolemic swine is characterized by the formation of proteoglycan-rich onlays in the fibrosa, which can occur prior to significant lipid accumulation, inflammatory cell infiltration, or myofibroblast activation. These characteristics mimic those of early human aortic valve disease, and thus the porcine model has utility for the study of early valve sclerosis. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Long-term Follow-up After Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis.

    Science.gov (United States)

    Salinas, Pablo; Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Ángel; Jiménez-Valero, Santiago; Galeote, Guillermo; López-Fernández, Teresa; Ramírez, Ulises; Riera, Luis; Plaza, Ignacio; Moreno, Isidro; Mesa, José María; López-Sendón, José Luis

    2016-01-01

    Transcatheter aortic valve implantation is used as an alternative to surgical valve replacement in patients with severe aortic stenosis who are considered high-surgical-risk or inoperable. Two of the main areas of uncertainty in this field are valve durability and long-term survival. This prospective single-center registry study from a tertiary hospital included all consecutive patients who underwent percutaneous aortic valve implantation between 2008 and 2012. Clinical follow-up lasted a minimum of 2.5 years and a maximum of 6.5 years. Valve Academic Research Consortium-2 definitions were used. Seventy-nine patients were included, with an immediate success rate of 94.9%. The median survival was 47.6 months (95% confidence intervals, 37.4-57.9 months), ie, 4 years. One quarter of deaths occurred in the first month, and most were of cardiovascular cause. After the first month, most deaths were due to noncardiovascular causes. The mean values of valve gradients did not increase during follow-up. The cumulative rate of prosthetic valve dysfunction was 15.3%, with no cases of repeat valve replacement. Half of the patients with aortic stenosis who underwent transcatheter aortic valve implantation were alive 4 years after the procedure. There was a 15.3% prosthetic valve dysfunction rate in cumulative follow-up, with no cases of repeat valve replacement. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  15. Aortic regurgitation after valve-sparing aortic root replacement: modes of failure.

    Science.gov (United States)

    Oka, Takanori; Okita, Yutaka; Matsumori, Masamichi; Okada, Kenji; Minami, Hitoshi; Munakata, Hiroshi; Inoue, Takeshi; Tanaka, Akiko; Sakamoto, Toshihito; Omura, Atsushi; Nomura, Takuo

    2011-11-01

    Despite the positive clinical results of valve-sparing aortic root replacement, little is known about the causes of reoperations and the modes of failure. From October 1999 to June 2010, 101 patients underwent valve-sparing aortic root replacement using the David reimplantation technique. The definition of aortic root repair failure included the following: (1) intraoperative conversion to the Bentall procedure; (2) reoperation performed because of aortic regurgitation; and (3) aortic regurgitation equal to or greater than a moderate degree at the follow-up. Sixteen patients were considered to have repair failure. Three patients required intraoperative conversion to valve replacement, 3 required reoperation within 3 months, and another 8 required reoperation during postoperative follow-up. At initial surgery 5 patients had moderate to severe aortic regurgitation, 6 patients had acute aortic dissections, 3 had Marfan syndrome, 2 had status post Ross operations, 3 had bicuspid aortic valves, and 1 had aortitis. Five patients had undergone cusp repair, including Arantius plication in 3 and plication at the commissure in 2. The causes of early failure in 6 patients included cusp perforation (3), cusp prolapse (3), and severe hemolysis (1). The causes of late failure in 10 patients included cusp prolapse (4), commissure dehiscence (3), torn cusp (2), and cusp retraction (1). Patients had valve replacements at a mean of 23 ± 20.9 months after reimplantation and survived. Causes of early failure after valve-sparing root replacement included technical failure, cusp lesions, and steep learning curve. Late failure was caused by aortic root wall degeneration due to gelatin-resorcin-formalin glue, cusp degeneration, or progression of cusp prolapse. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Combined surgical and catheter-based treatment of extensive thoracic aortic aneurysm and aortic valve stenosis

    DEFF Research Database (Denmark)

    De Backer, Ole; Lönn, Lars; Søndergaard, Lars

    2015-01-01

    valve stenosis (AS) who are considered at high risk for surgical aortic valve replacement. In this report, we describe the combined surgical and catheter-based treatment of an extensive TAA and AS. To our knowledge, this is the first report of hybrid TAA repair combined with TAVR....

  17. Aortic dilatation in patients with prosthetic aortic valve: comparison of MRI and echocardiography.

    Science.gov (United States)

    von Knobelsdorff-Brenkenhoff, Florian; Rudolph, André; Wassmuth, Ralf; Abdel-Aty, Hassan; Schulz-Menger, Jeanette

    2010-05-01

    Patients with prosthetic aortic valve have an increased risk for aortic dissection, which rises further with growing aortic diameters. Thus, accurate aortic monitoring is required. As transthoracic echocardiography (TTE), the current clinical standard, is frequently restricted to the proximal ascending aorta, the use of two-dimensional cardiovascular magnetic resonance (2D-CMR) in transverse orientation was investigated as a screening tool to assess ascending aortic dimensions. Fast, non-contrast-enhanced, non-breath-hold, steady-state free-precession (SSFP) sequences (1.5 Tesla, slice thickness 7 mm, gap 1.8 mm, scan time 10-15 s) were applied to image the thorax in transverse planes. To test the accuracy of aortic dimensions obtained in this way, comparison was made to contrast-enhanced three-dimensional MR angiography (3D-MRA) as the 'gold standard' in 30 patients with aortic or aortic valve disease. After validation, transverse 2D-CMR was used to assess ascending aortic dimensions in 65 patients with aortic bioprostheses, and the results were compared to those acquired with TTE. Data acquired with both 2D-CMR and 3D-MRA agreed well when assessing ascending aortic diameters (r = 0.99; p 2.1 cm/m2) was present in 38.5% of 2D-CMR cases and in 11.5% of TTE cases. The intra- and inter-observer variabilities to assess aortic dimensions by 2D-CMR were 2.1 +/- 1.9% and 4.3 +/- 3.7%, respectively. Imaging of the complete thorax in transverse orientation using fast, non-contrast-enhanced SSFP images provided an accurate and reliable approach to screen for aortic dilatation. In patients with aortic bioprostheses, 2D-CMR revealed a high prevalence of aortic dilatation, which was considerably underestimated by TTE.

  18. Preventative valve-sparing aortic root replacement and pregnancy outcome in Marfan syndrome.

    Science.gov (United States)

    Sokol, Vesna; Zlopasa, Gordan; Herman, Mislav; Planinić, Pavao; Micevska, Ana

    2012-06-01

    In Marfan syndrome, with dilatation of the aortic root secondary to an underlying connective tissue defect, pregnancy can cause hemodynamic stress leading to the development of an aortic aneurysm and even a fatal aortic dissection. In the presence of existing aortic root enlargement and a family history of aortic dissection, preventative elective surgery is suggested. Aortic root replacement with or without a valve-sparing procedure is superior to total aortic root replacement with prosthetic valve/tube graft. It provides excellent survival with low rates of aortic - valve related complications.

  19. Spontaneous Thrombosis of a Bicuspid Aortic valve due to Primary Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Sarah Farrell

    2010-08-01

    Full Text Available We present the case of a 51-year-old man who was admitted as an emergency with spontaneous thrombosis of the aortic valve and ascending aorta. At operation he was found to have a congenitally bicuspid aortic valve and subsequent investigation revealed primary antiphospholipid syndrome. He underwent successful removal of the thrombus combined with mechanical replacement of the aortic valve.

  20. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.

    Directory of Open Access Journals (Sweden)

    Jochen Wöhrle

    Full Text Available The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California system was optimized to reduce residual aortic regurgitation and vascular complications.235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77, 26mm (N = 91 or 29mm (N = 67 valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6% and stroke (2.1% were low.In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes.ClinicalTrials.gov NCT02162069.

  1. Lipoprotein(a Induces Human Aortic Valve Interstitial Cell Calcification

    Directory of Open Access Journals (Sweden)

    Bin Yu, PhD

    2017-08-01

    Full Text Available Lipoprotein(a, or Lp(a, significantly increased alkaline phosphatase activity, release of phosphate, calcium deposition, hydroxyapatite, cell apoptosis, matrix vesicle formation, and phosphorylation of signal transduction proteins; increased expression of chondro-osteogenic mediators; and decreased SOX9 and matrix Gla protein (p < 0.001. Inhibition of MAPK38 and GSK3β significantly reduced Lp(a-induced calcification of human aortic valve interstitial cells (p < 0.001. There was abundant presence of Lp(a and E06 immunoreactivity in diseased human aortic valves. The present study demonstrates a causal effect for Lp(a in aortic valve calcification and suggests that interfering with the Lp(apathway could provide a novel therapeutic approach in the management of this debilitating disease.

  2. Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement.

    Science.gov (United States)

    Goldstone, Andrew B; Chiu, Peter; Baiocchi, Michael; Lingala, Bharathi; Patrick, William L; Fischbein, Michael P; Woo, Y Joseph

    2017-11-09

    In patients undergoing aortic-valve or mitral-valve replacement, either a mechanical or biologic prosthesis is used. Biologic prostheses have been increasingly favored despite limited evidence supporting this practice. We compared long-term mortality and rates of reoperation, stroke, and bleeding between inverse-probability-weighted cohorts of patients who underwent primary aortic-valve replacement or mitral-valve replacement with a mechanical or biologic prosthesis in California in the period from 1996 through 2013. Patients were stratified into different age groups on the basis of valve position (aortic vs. mitral valve). From 1996 through 2013, the use of biologic prostheses increased substantially for aortic-valve and mitral-valve replacement, from 11.5% to 51.6% for aortic-valve replacement and from 16.8% to 53.7% for mitral-valve replacement. Among patients who underwent aortic-valve replacement, receipt of a biologic prosthesis was associated with significantly higher 15-year mortality than receipt of a mechanical prosthesis among patients 45 to 54 years of age (30.6% vs. 26.4% at 15 years; hazard ratio, 1.23; 95% confidence interval [CI], 1.02 to 1.48; P=0.03) but not among patients 55 to 64 years of age. Among patients who underwent mitral-valve replacement, receipt of a biologic prosthesis was associated with significantly higher mortality than receipt of a mechanical prosthesis among patients 40 to 49 years of age (44.1% vs. 27.1%; hazard ratio, 1.88; 95% CI, 1.35 to 2.63; Pbiologic prosthesis than among recipients of a mechanical prosthesis. Patients who received mechanical valves had a higher cumulative incidence of bleeding and, in some age groups, stroke than did recipients of a biologic prosthesis. The long-term mortality benefit that was associated with a mechanical prosthesis, as compared with a biologic prosthesis, persisted until 70 years of age among patients undergoing mitral-valve replacement and until 55 years of age among those undergoing

  3. Autopsy after transcatheter aortic valve implantation.

    Science.gov (United States)

    van Kesteren, F; Wiegerinck, E M A; Rizzo, S; Baan, J; Planken, R N; von der Thüsen, J H; Niessen, H W M; van Oosterhout, M F M; Pucci, A; Thiene, G; Basso, C; Sheppard, M N; Wassilew, K; van der Wal, A C

    2017-03-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview of the autopsy findings in patients with TAVI in their medical history divided by the timing of death with specific interest in the added value of autopsy over a solely clinically determined cause of death. In 8 European centres, 72 cases with autopsy reports were available. Autopsies were divided according to the time interval of death and reports were analysed. In 32 patients who died ≤72 h postprocedure, mortality resulted from cardiogenic or haemorrhagic shock in 62.5 and 34.4%, respectively. In 31 patients with mortality >72 h to ≤30 days, cardiogenic shock was the cause of death in 51.6% followed by sepsis (22.6%) and respiratory failure (9.7%). Of the nine patients with death >30 days, 88.9% died of sepsis, caused by infective endocarditis in half of them. At total of 12 patients revealed cerebrovascular complications. Autopsy revealed unexpected findings in 61.1% and resulted in a partly or completely different cause of death as was clinically determined. Autopsy on patients who underwent TAVI reveals specific patterns of cardiovascular pathology that clearly relate to the time interval between TAVI and death and significantly adds to the clinical diagnosis. Our data support the role of autopsy including investigation of the cerebrum in the quickly evolving era of cardiac device technology.

  4. Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation With Acute Refractory Cardiogenic Shock.

    Science.gov (United States)

    Achkouty, Guy; Amabile, Nicolas; Zannis, Konstantinos; Veugeois, Aurélie; Caussin, Christophe

    2018-03-01

    From January 2013 to January 2017, 686 consecutive patients were referred to our centre for transcatheter aortic valve replacement, including 5 subjects with severe aortic regurgitation and acute refractory cardiogenic shock. These patients were contraindicated for surgical treatment by the heart team because of high surgical risk (median logistic EuroSCORE: 74.6/Society of Thoracic Surgeons score: 37.9). The success rate of valve implantation was 100% through transfemoral access with self-expandable devices. The observed 30-day mortality rate was 20%. Hence, the transcatheter aortic valve replacement procedure might represent a successful and life-saving intervention for treatment of patients with severe aortic regurgitation who present with acute refractory cardiogenic shock. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation.

    Science.gov (United States)

    Morita, Shigeki

    2016-08-01

    The treatment strategy for aortic stenosis (AS) has been changing due to newly developed valvular prostheses and trans-catheter aortic valve implantation (TAVI). To determine the role of new modalities for AS with a small aortic root, papers using the concept of prosthesis-patient mismatch (PPM) were reviewed. First, to determine the cut-off value of the indexed effective orifice area (IEOA) for defining PPM, the studies of surgical aortic valve replacement (SAVR) with a follow-up longer than 5 years and a patient number larger than 500 were reviewed. Second, the papers comparing TAVI and SAVR were reviewed. Furthermore, the prevalence of PPM was reviewed, with the addition of papers on aortic root enlargement, sutureless AVR, and aortic valve reconstruction with autologous pericardium. The results of the long-term survival after aortic valve replacement (AVR) have indicated that an IEOA less than 0.65 cm(2)/m(2) should be avoided in all cases, whereas the indications for patients with an IEOA between 065 and 0.85 cm(2)/m(2) should be determined by considering multiple factors. A large body size and younger age have a significantly negative influence on the long-term survival. In Asian population, the prevalence of PPM was low, despite the fact that the size of the aortic annulus was small. The IEOA after TAVI was larger than after surgical AVR in population-matched studies. To evaluate the role of TAVI and other modalities for a small aortic root, studies with a longer follow-up and larger volume are thus warranted.

  6. [Comparison of aortic annular diameter defined by different measurement mordalities before transcatheter aortic valve implantation].

    Science.gov (United States)

    Qi, R X; You, X D; Pu, Z X; Yang, Q; Huang, Z X; Zhou, L M; Huang, P T

    2017-05-24

    Objective: To compare aortic annular diameter measured by transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT) in patients with severe aortic stenosis, and to evaluate the impact on selection of prosthetic valve type in transcatheter aortic valve implantation (TAVI). Methods: Clinical data of 138 patients with severe aortic stenosis referred for TAVI between January 2014 and June 2016 in our hospital were retrospectively analyzed.The difference of aortic annular diameter measured by TTE, TEE, and MSCT were compared.TTE was performed after TAVI to evaluate the accuracy of measurement before TAVI. Results: (1) Aortic annular diameter was (23.37±2.22) mm by TTE and (23.52±1.70) mm by TEE ( P =0.12). Pearson correlation analysis showed that aortic annular diameter measured by TTE was correlated to that measured by TEE ( r =0.87, P TTE and TTE (all P TTE and TEE measurements are smaller than that from MSCT.In the absence of a gold standard, selection of prosthetic valve type in TAVI procedure should rely on comprehensive considerations, which is of importance to get good clinical results for severe aortic stenosis patients underwent TAVI.

  7. Incidence and progression of mild aortic regurgitation after Tirone David reimplantation valve-sparing aortic root replacement.

    Science.gov (United States)

    Stephens, Elizabeth H; Liang, David H; Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Mitchell, R Scott; Miller, D Craig

    2014-01-01

    The study objective was to determine whether recurrent or residual mild aortic regurgitation, which occurs after valve-sparing aortic root replacement, progresses over time. Between 2003 and 2008, 154 patients underwent Tirone David-V valve-sparing aortic root replacement; 96 patients (62%) had both 1-year (median, 12 ± 4 months) and mid-term (62 ± 22 months) transthoracic echocardiograms available for analysis. Age of patients averaged 38 ± 13 years, 71% were male, 31% had a bicuspid aortic valve, 41% had Marfan syndrome, and 51% underwent aortic valve repair, predominantly cusp free margin shortening. Forty-one patients (43%) had mild aortic regurgitation on 1-year echocardiogram. In 85% of patients (n = 35), mild aortic regurgitation remained stable on the most recent echocardiogram (median, 57 ± 20 months); progression to moderate aortic regurgitation occurred in 5 patients (12%) at a median of 28 ± 18 months and remained stable thereafter; severe aortic regurgitation developed in 1 patient, eventually requiring reoperation. Five patients (5%) had moderate aortic regurgitation at 1 year, which did not progress subsequently. Two patients (2%) had more than moderate aortic regurgitation at 1 year, and both ultimately required reoperation. Although mild aortic regurgitation occurs frequently after valve-sparing aortic root replacement, it is unlikely to progress over the next 5 years and should not be interpreted as failure of the valve-preservation concept. Further, we suggest that mild aortic regurgitation should not be considered nonstructural valve dysfunction, as the 2008 valve reporting guidelines would indicate. We need 10- to 15-year follow-up to learn the long-term clinical consequences of mild aortic regurgitation early after valve-sparing aortic root replacement. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Early results of valve-sparing ascending aortic replacement in type A aortic dissection and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    М. Л. Гордеев

    2016-08-01

    Full Text Available Aim: The study was designed to investigate predictors of effective valve-sparing ascending aortic replacement in patients with Stanford type A aortic dissection combined with aortic insufficiency and to analyze efficacy and safety of this kind of surgery.Methods: From January 2010 to December 2015, 49 patients with Stanford type A aortic dissection combined with aortic insufficiency underwent ascending aortic replacement. All patients were divided into 3 groups: valve-sparing procedures (group 1, n = 11, combined aortic valve and supracoronary ascending aortic replacement (group 2, n = 12, and Bentall procedure (group 3, n = 26. We assessed the initial status of patients, incidence of complications and efficacy of valve-sparing ascending aortic replacement.Results: The hospital mortality rate was 8.2% (4/49 patients. The amount of surgical correction correlated with the initial diameter of the aorta at the level of the sinuses of Valsalva. During the hospital period, none of patients from group 1 developed aortic insufficiency exceeding Grade 2 and the vast majority of patients had trivial aortic regurgitation. The parameters of cardiopulmonary bypass, cross-clamp time and circulatory arrest time did not correlate with the initial size of the ascending aorta and aortic valve blood flow impairment, neither did they influence significantly the incidence and severity of neurological complications. The baseline size of the ascending aorta and degree of aortic regurgitation did not impact the course of the early hospital period.Conclusions: Supracoronary ascending aortic replacement combined with aortic valve repair in ascending aortic dissection and aortic regurgitation is effective and safe. The initial size of the ascending aorta and aortic arch do not influence immediate results. The diameter of the aorta at the level of the sinuses of Valsalva and the condition of aortic valve leaflets could be considered as the limiting factors. Further long

  9. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  10. Uncommon acquired Gerbode defect following extensive bicuspid aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Dores Hélder

    2012-02-01

    Full Text Available Abstract Gerbode defect is a rare type of left ventricle to right atrium shunt. It is usually congenital in origin, but acquired cases are also described, mainly following infective endocarditis, valve replacement, trauma or acute myocardial infarction. We report a case of a 50-year-old man who suffered an extensive and complex infective endocarditis involving a bicuspid aortic valve, the mitral-aortic intervalvular fibrosa and the anterior leaflet of the mitral valve. After dual valve replacement and annular reconstruction, a shunt between the left ventricle and the right atrium - Gerbode defect, and a severe leak of the mitral prosthesis were detected. Reintervention was performed with successful shunt closure with an autologous pericardial patch and paravalvular leak correction. No major complications occurred denying the immediate post-surgery period and the follow-up at the first year was uneventful.

  11. Perceval S aortic valve implantation in an achondroplastic Dwarf

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  12. Perceval S aortic valve implantation in an achondroplastic Dwarf.

    Science.gov (United States)

    Baikoussis, Nikolaos G; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  13. A Quantitative Study of Simulated Bicuspid Aortic Valves

    Science.gov (United States)

    Szeto, Kai; Nguyen, Tran; Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan

    2010-11-01

    Previous studies have shown that congentially bicuspid aortic valves develop degenerative diseases earlier than the standard trileaflet, but the causes are not well understood. It has been hypothesized that the asymmetrical flow patterns and turbulence found in the bileaflet valves together with abnormally high levels of strain may result in an early thickening and eventually calcification and stenosis. Central to this hypothesis is the need for a precise quantification of the differences in the strain rate levels between bileaflets and trileaflet valves. We present here some in-vitro dynamic measurements of the spatial variation of the strain rate in pig aortic vales conducted in a left ventricular heart flow simulator device. We measure the strain rate of each leaflet during the whole cardiac cycle using phase-locked stereoscopic three-dimensional image surface reconstruction techniques. The bicuspid case is simulated by surgically stitching two of the leaflets in a normal valve.

  14. Ascending Aortic Wall Cohesion: Comparison of Bicuspid and Tricuspid Valves

    Directory of Open Access Journals (Sweden)

    Jaroslav Benedik

    2012-01-01

    Full Text Available Objectives. Bicuspid aortic valve (AV represents the most common form of congenital AV malformation, which is frequently associated with pathologies of the ascending aorta. We compared the mechanical properties of the aortic wall between patients with bicuspid and tricuspid AV using a new custom-made device mimicking transversal aortic wall shear stress. Methods. Between 03/2010 and 07/2011, 190 consecutive patients undergoing open aortic valve replacement at our institution were prospectively enrolled, presenting either with a bicuspid (group 1, n=44 or a tricuspid (group 2, n=146 AV. Aortic wall specimen were examined with the “dissectometer” resulting in nine specific aortic-wall parameters derived from tensile strength curves (TSC. Results. Patients with a bicuspid AV showed significantly more calcified valves (43.2% versus 15.8%, P<0.001, and a significantly thinner aortic wall (2.04±0.42 mm versus 2.24±0.41 mm, P=0.008. Transesophageal echocardiography diameters (annulus, aortic sinuses, and sinotubular junction were significantly larger in the bicuspid group (P=0.003, P=0.02, P=0.01. We found no difference in the aortic wall cohesion between both groups as revealed by shear stress testing (P=0.72, P=0.40, P=0.41. Conclusion. We observed no differences of TSC in patients presenting with tricuspid or bicuspid AVs. These results may allow us to assume that the morphology of the AV and the pathology of the ascending aorta are independent.

  15. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    Science.gov (United States)

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. © 2014 Blackwell Verlag GmbH.

  16. Factors associated with the development of aortic valve regurgitation over time after two different techniques of valve-sparing aortic root surgery.

    Science.gov (United States)

    Hanke, Thorsten; Charitos, Efstratios I; Stierle, Ulrich; Robinson, Derek; Gorski, Armin; Sievers, Hans-H; Misfeld, Martin

    2009-02-01

    Early results after aortic valve-sparing root reconstruction are excellent. Longer-term follow-up, especially with regard to aortic valve function, is required for further judgment of these techniques. Between July of 1993 and September of 2006, 108 consecutive patients (mean age 53.0 +/- 15.8 years) underwent the Yacoub operation (group Y) and 83 patients underwent the David operation (group D). Innovative multilevel hierarchic modeling methods were used to analyze aortic regurgitation over time. In general, aortic regurgitation increased with time in both groups. Factors associated with the development of a significant increase in aortic regurgitation were Marfan syndrome, concomitant cusp intervention, and preoperative aortic anulus dimension. In Marfan syndrome, the initial aortic regurgitation was higher in group Y versus group D (0.56 aortic regurgitation vs 0.29 aortic regurgitation, P = .049), whereas the mean annual progression rate of aortic regurgitation was marginally higher in group Y (0.132 aortic regurgitation vs 0.075 aortic regurgitation, P = .1). Concomitant cusp intervention was associated with a significant aortic regurgitation increase in both groups (P Marfan syndrome and a large preoperative aortic annulus diameter were better treated with the reimplantation technique, whereas those with a smaller diameter were better treated with the remodeling technique. Concomitant free-edge plication of prolapsing cusps was disadvantageous in both groups. Considering these factors may serve to improve the aortic valve longevity after valve-sparing aortic root surgery.

  17. Transcatheter aortic valve implantation in bicuspid anatomy: procedural results with two different types of valves.

    Science.gov (United States)

    Presbitero, Patrizia; Iannetta, Loredana; Pagnotta, Paolo; Reimers, Bernhard; Rossi, Marco L; Zavalloni Parenti, Dennis; Bianchi, Giovanni; Bedogni, Francesco

    2018-04-01

    It is well known that bicuspid valve stenosis can be treated with transcatheter aortic valve implantation (TAVI) even if specific issues can cause problems: dilatation of ascending aorta, possible aorthopathy, eccentricity of the valve and calcium distribution in leaflets and in commissures. We classified Bicuspid aortic valve (BAV) in type 0 (2 cusps and no raphe), and type 1 (2 cusps and one or more raphes). The aim of the present study was to report the results of two types of valve (CoreValve from 2009 to 2016 and Lotus valve from 2014 to 2017) in a consecutive series of BAV patients treated in 2 Italian centers. A total of 30 patients with BAV underwent TAVI from September 2009 to March 2017. Mean age was 78±8 years, 54.5% were males and 7.4% had peripheral vasculopathy, 6.5% previous stroke or TIA, 15.6% previous PCI and 9.4% previous coronary artery bypass grafting. Ten patients (30.3%) had a type 1; mean aortic valvular gradient was 57.7±17.7 mmHg; aortic valvular area was 0.7±0.2 mm2, left ventricular ejection fraction was 51.4±10.0% and ascending aorta was 41.0±5.6 mm. Among these 30 patients, 16 of them (group 1) undergone CoreValve implantation and 14 (group 2) undergone Lotus valve implantation. Patients in the first group had a higher Logistic Euroscore (P<0.001) and higher AVA (P=0.026) and valve area CT (P=0.003). Device size in group1 was more often bigger than in group 2 (P<0.001) and postdilatation was never used in the last group. Group 1 had a significant more frequent aortic regurgitation ≥2 assessed with angiography (28.6% vs. 0%; P=0.05). A non-statistically significant higher rate of second valve implantation (6.2% vs. 0%; P=1.00) was also observed. New permanent pacemaker implantation (40.0% vs. 35.7%; P=0.812) was equal in both valves. Postprocedural aortic regurgitation is still an issue in BAV undergone TAVI when: 1) the annulus is big; 2) when we are using self-expandable valves; and 3) in type 0 valves. Lotus valve, with a

  18. Shape of the dilated aorta in children with bicuspid aortic valve

    International Nuclear Information System (INIS)

    Mart, Christopher R; McNerny, Bryn E

    2013-01-01

    The dilated aorta in adults with bicuspid aortic valve has been shown to have different shapes, but it is not known if this occurs in children. This observational study was performed to determine if there are different shapes of the dilated aorta in children with bicuspid aortic valve and their association with age, gender, hemodynamic alterations, and degree of aortic enlargement. One hundred and eighty-seven echocardiograms done on pediatric patients (0 – 18 years) for bicuspid aortic valve, during 2008, were reviewed. Aortic valve morphology, shape/size of the aorta, and pertinent hemodynamic alterations were documented. Aortic dilation was felt to be present when at least one aortic segment had a z-score > 2.0; global aortic enlargement was determined by summing the aortic segment z-scores. The aortic shape was assessed by age, gender, valve morphology, and hemodynamic alterations. Aortic dilation was present in 104/187 patients. The aorta had six different shapes designated from S1 through S6. There was no association between the aortic shape and gender, aortic valve morphology, or hemodynamic abnormalities. S3 was the most common after the age of six years and was associated with the most significant degree of global aortic enlargement. The shape of the dilated aorta in children with bicuspid aortic valve does not occur in a uniform manner and multiple shapes are seen. S2 and S3 are most commonly seen. As aortic dilation becomes more significant, a single shape (S3) becomes the dominant pattern

  19. Case Report: Prothesis-patient mismatch after aortic valve replacement.

    Science.gov (United States)

    Rodriguez-Ospina, Luis; Garcia-Morell, Juan; Rodriguez-Monserrate, Carla P; Valentin-Nieves, Julio

    2015-01-01

    Valve replacement is the standard surgical treatment of diseased valves that cannot be repaired. The main goal of replacement is to exchange the diseased valve with one that has the engineering and hemodynamics as close as possible to the disease free native valve. However due to mechanical and fluid dynamic constraints all prosthetic heart valves (PHVs) are smaller than normal and thus are inherently stenotic. This represents a challenge when it comes time to replace a valve. The correct valve with the correct and matching profile has to be selected before the procedure to avoid possible complications. It is well recognized that patients are also prone to patient-prosthesis mismatch at long term which could have consequences in the clinical outcomes (1). The evaluation of patient-prosthesis mismatch (PPM) has not been sufficiently emphasized in common practice. Failure to recognize this fact may lead to significant hemodynamic impairment and worsening of the clinical status over the time. Making efforts to identifying patients at risk may decrease the prevalence of PPM, the economic impact to our health system, the morbidity and mortality involved in these cases as well as creates efforts to standardized pre-operative protocols to minimized risk of PPM. We present a case of a 78 years old male patient who underwent aortic valve replacement due severe aortic stenosis, afterwards his clinical course got complicated with several admissions for shortness of breath and decompensated congestive heart failure (CHF).

  20. Impact of hypertension on left ventricular structure in patients with asymptomatic aortic valve stenosis (a SEAS substudy)

    DEFF Research Database (Denmark)

    Rieck, Ashild E; Cramariuc, Dana; Staal, Eva M

    2010-01-01

    Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis.......Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis....

  1. Collagen analysis of the ascending aortic dilatation associated with bicuspid aortic valve disease compared with tricuspid aortic valve.

    Science.gov (United States)

    Navarrete Santos, Alexander; Yan, Junfeng; Lochmann, Peter; Pfeil, Heike; Petersen, Michael; Simm, Andreas; Treede, Hendrik; Sievers, Hans H; Mohamed, Salah A

    2016-12-01

    Dilatation of the ascending aorta is a common occurrence in patients with bicuspid aortic valve (BAV). The aim of the current study was to characterize collagen content in advanced glycation end products (AGEs) of dilated aortic tissue from two distinct areas, concave and convex aortic sites in patients with BAV and TAV. Collagen contents extracted from 100 mg tissue was isolated by enzymatic digestion using pepsin and the nondigested material was further digested using cyanogen bromide, insoluble collagen fraction (ICF) was extracted by hydrochloric acid hydrolysis. BAV tissue showed diminished fluorescence of the pepsin extracted fraction (PEF) compared with TAV tissue (12.4 ± 1.0% vs 32.9 ± 7.6%, p = 0.05). Patients with BAV had PEF of collagens significantly diminished in the dilated ascending aorta, especially in its convex portion, in course of aging and increment of dilated diameters. It is suggestible that BAV patients present more highly AGE-modified collagens in their ascending aorta.

  2. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Schuhbaeck, Annika, E-mail: annika.schuhbaeck@uk-erlangen.de [Department of Cardiology, University of Erlangen, Erlangen (Germany); Weingartner, Christina [Department of Cardiology, University of Gießen, Giessen (Germany); Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed [Department of Cardiology, University of Erlangen, Erlangen (Germany); Rixe, Johannes; Nef, Holger [Department of Cardiology, University of Gießen, Giessen (Germany); Schneider, Christian [Department of Radiology, University of Gießen, Giessen (Germany); Lell, Michael; Uder, Michael [Department of Radiology, University of Erlangen, Erlangen (Germany); Ensminger, Stephan [Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen (Germany); Feyrer, Richard; Weyand, Michael [Department of Cardiothoracic Surgery, University of Erlangen, Erlangen (Germany); Achenbach, Stephan [Department of Cardiology, University of Erlangen, Erlangen (Germany)

    2015-07-15

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification.

  3. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  4. Comparison of ascending aortic cohesion between patients with bicuspid aortic valve stenosis and regurgitation.

    Science.gov (United States)

    Benedik, Jaroslav; Dohle, Daniel S; Wendt, Daniel; Pilarczyk, Kevin; Price, Vivien; Mourad, Fanar; Zykina, Elizaveta; Stebner, Ferdinand; Tsagakis, Konstantinos; Jakob, Heinz

    2014-12-01

    A bicuspid aortic valve (BAV) is commonly associated with aortic wall abnormalities, including dilatation of the ascending aorta and increased potential for aortic dissection. We compared the mechanical properties of the aortic wall of BAV patients with aortic valve stenosis (AS) and regurgitation (AR) using a dissectometer, a device mimicking transverse aortic wall shear stress. Between March 2010 and February 2013, 85 consecutive patients with bicuspid aortic valve undergoing open aortic valve replacement at our institution were prospectively enrolled, presenting either with stenosis (Group 1, n = 58) or regurgitation (Group 2, n = 27). Aortic wall cohesion measured by the dissectometer (Parameters P7, P8 and P9), aortic diameters measured by transoesophageal echocardiography (TOE) and thickness of the wall were compared. One patient presenting with the Marfan syndrome was excluded from the study. Patients with aortic regurgitation were significantly younger (48.2 ± 15.8 vs 64.7 ± 10.7, P group (27.3 ± 3.6 vs 25.5 ± 2.4, P = 0.008; 41.1 ± 7.7 vs 36.7 ± 8.0, P = 0.011; 37.6 ± 9.7 vs 33.8 ± 9.1, P = 0.049). The ascending aortic diameter did not differ (43.2 ± 10.6 vs 40.3 ± 9.1, P = 0.292). Patients with AR had significantly worse aortic cohesion, as measured by shear stress testing (P7: 97.2 ± 45.0 vs 145.5 ± 84.9, P = 0.015; P8: 2.00 ± 0.65 vs 3.82 ± 1.56, P cohesion, a thicker aortic wall and a larger aortic root in patients presenting with bicuspid AR compared with patients with AS. These results suggest that bicuspid AR represents a different disease process with possible involvement of the ascending aorta, as demonstrated by dissectometer examination. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Comparison of the size of artificial aortic valve with ring diameter by echocardiography

    Directory of Open Access Journals (Sweden)

    Rangbarnegad II

    1997-07-01

    Full Text Available In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpose was to find a logical correlation to help the surgeons to order the correct size of aortic prosthetic valve in advance of surgery. 26 patients with aortic valve disease were studied from 1972 till 1974 who underwent aortic valve replacement surgery. Now, it is possible to predict the accurate size of aortic mechanical valve prosthesis before surgery

  6. Aortic valve disease : novel imaging insights from diagnosis to therapy

    NARCIS (Netherlands)

    Ewe, See Hooi

    2016-01-01

    The general introduction of this thesis outlines the epidemiology and the impact of aortic valve disease in the western world. The thesis further discusses the current and future role of advanced cardiac imaging modalities, using 3D echocardiography and speckle tracking echocardiography strain

  7. Heart failure after aortic valve substitution due to severe hypothyroidism

    DEFF Research Database (Denmark)

    Munk, Kim; Sørensen, Stine Heidenheim; Andersen, Niels Holmark

    2008-01-01

    We report a case of a 70-year-old female with considerable co-morbidities (Type 2 diabetes, Leiden factor V mutation, mild to moderate chronic obstructive pulmonary disease) and a recent biological aortic valve substitution, who was admitted due to circulatory collapse caused by severe heart...

  8. Bicuspid aortic valve hemodynamics: a fluid-structure interaction study

    Science.gov (United States)

    Chandra, Santanu; Seaman, Clara; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.

  9. Preventative Valve-Sparing Aortic Root Replacement and Pregnancy Outcome in Marfan Syndrome

    OpenAIRE

    Sokol, Vesna; Zlopaša, Gordan; Herman, Mislav; Planinić, Pavao; Micevska, Ana

    2012-01-01

    In Marfan syndrome, with dilatation of the aortic root secondary to an underlying connective tissue defect, pregnancy can cause hemodynamic stress leading to the development of an aortic aneurysm and even a fatal aortic dissection. In the presence of existing aortic root enlargement and a family history of aortic dissection, preventative elective surgery is suggested. Aortic root replacement with or without a valve-sparing procedure is superior to total aortic root replacement with ...

  10. Calcific Aortic Valve Disease: a Developmental Biology Perspective.

    Science.gov (United States)

    Dutta, Punashi; Lincoln, Joy

    2018-03-08

    This review aims to highlight the past and more current literature related to the multifaceted pathogenic programs that contribute to calcific aortic valve disease (CAVD) with a focus on the contribution of developmental programs. Calcification of the aortic valve is an active process characterized by calcific nodule formation on the aortic surface leading to a less supple and more stiffened cusp, thereby limiting movement and causing clinical stenosis. The mechanisms underlying these pathogenic changes are largely unknown, but emerging studies have suggested that signaling pathways common to valvulogenesis and bone development play significant roles and include Transforming Growth Factor-β (TGF-β), bone morphogenetic protein (BMP), Wnt, Notch, and Sox9. This comprehensive review of the literature highlights the complex nature of CAVD but concurrently identifies key regulators that can be targeted in the development of mechanistic-based therapies beyond surgical intervention to improve patient outcome.

  11. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    Science.gov (United States)

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  12. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    Science.gov (United States)

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  13. Acute Right Coronary Ostial Stenosis during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Sarwar Umran

    2012-01-01

    Full Text Available We report a rare case of acute right coronary artery stenosis developing in a patient undergoing aortic valve replacement. We present a case report with a brief overview of the literature relating to coronary artery occlusion associated with cardiac valve surgery - the theories and treatments are discussed. A 85 year-old female was admitted under the care of the cardiothoracic team with signs and symptoms of heart failure. Investigations, including cardiac echocardiography and coronary angiography, indicated a critical aortic valve stenosis. Intraoperative right ventricular failure ensued post aortic valve replacement. Subsequent investigations revealed an acute occlusion of the proximal right coronary artery with resultant absence of distal flow supplying the right ventricle. An immediate right coronary artery bypass procedure was performed with resolution of the right ventricular failure. Subsequent weaning off cardiopulmonary bypass was uneventful and the patient continued to make excellent recovery in the postoperative phase. To our knowledge this is one of the few documented cases of intraoperative acute coronary artery occlusion developing during valve surgery. However, surgeons should be aware of the potential for acute occlusion so that early recognition and rapid intervention can be instituted.

  14. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  15. Prosthetic aortic valve selection: current patient experience, preferences and knowledge

    Science.gov (United States)

    Korteland, Nelleke M; Bras, Frans J; van Hout, Fabienne M A; Kluin, Jolanda; Klautz, Robert J M; Bogers, Ad J J C; Takkenberg, Johanna J M

    2015-01-01

    Objective Current clinical practice guidelines advocate shared decision-making (SDM) in prosthetic valve selection. This study assesses among adult patients accepted for aortic valve replacement (AVR): (1) experience with current clinical decision-making regarding prosthetic valve selection, (2) preferences for SDM and risk presentation and (3) prosthetic valve knowledge and numeracy. Methods In a prospective multicentre cohort study, AVR patients were surveyed preoperatively and 3 months postoperatively. Results 132 patients (89 males/43 females; mean age 67 years (range 23–86)) responded preoperatively. Decisional conflict was observed in 56% of patients, and in 25% to such an extent that it made them feel unsure about the decision. 68% wanted to be involved in decision-making, whereas 53% agreed that they actually were. 69% were able to answer three basic knowledge questions concerning prosthetic valves correctly. 56% were able to answer three basic numeracy questions correctly. Three months postsurgery, 90% (n=110) were satisfied with their aortic valve prosthesis, with no difference between mechanical and bioprosthetic valve recipients. Conclusions In current clinical practice, many AVR patients experience decisional conflict and suboptimal involvement in prosthetic valve selection, and exhibit impaired knowledge concerning prosthetic valves and numeracy. Given the broad support for SDM among AVR patients and the obvious need for understandable information, to-be-developed tools to support SDM in the setting of prosthetic valve selection will help to improve quality of decision-making, better inform and actively involve patients, and reduce decisional conflict. Trial registration number NTR3618. PMID:25893105

  16. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves

    DEFF Research Database (Denmark)

    Chakravarty, Tarun; Søndergaard, Lars; Friedman, John

    2017-01-01

    rates of transient ischaemic attacks (TIAs; 4·18 TIAs per 100 person-years vs 0·60 TIAs per 100 person-years; p=0·0005) and all strokes or TIAs (7·85 vs 2·36 per 100 person-years; p=0·001). INTERPRETATION: Subclinical leaflet thrombosis occurred frequently in bioprosthetic aortic valves, more commonly...... and transcatheter aortic valves and the effect of novel oral anticoagulants (NOACs) on the subclinical leaflet thrombosis and subsequent valve haemodynamics and clinical outcomes on the basis of two registries of patients who had CT imaging done after TAVR or SAVR. METHODS: Patients enrolled between Dec 22, 2014......, and Jan 18, 2017, in the RESOLVE registry, and between June 2, 2014, and Sept 28, 2016, in the SAVORY registry, had CT imaging done with a dedicated four-dimensional volume-rendered imaging protocol at varying intervals after TAVR and SAVR. We defined subclinical leaflet thrombosis as the presence...

  17. Evolving Concepts in Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Nijhoff, F.

    2015-01-01

    Part I of the present thesis is dedicated to implantation technique and the clinical performance of new valve prostheses. A satisfactory TAVI result not solely depends on patient characteristics, but also relies on proper valve positioning and final placement. Moreover, prosthetic design is

  18. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  19. Surgical treatment of aortic valve endocarditis: a 26-year experience

    Directory of Open Access Journals (Sweden)

    Taylan Adademir

    2014-03-01

    Full Text Available Objective: We have retrospectively analyzed the results of the operations made for aortic valve endocarditis in a single center in 26 years. Methods: From June 1985 to January 2011, 174 patients were operated for aortic valve endocarditis. One hundred and thirty-eight (79.3% patients were male and the mean age was 39.3±14.4 (9-77 years. Twenty-seven (15.5% patients had prosthetic valve endocarditis. The mean duration of follow-up was 7.3±4.2 years (0.1-18.2 adding up to a total of 1030.8 patient/years. Results: Two hundred and eighty-two procedures were performed. The most frequently performed procedure was aortic valve replacement with mechanical prosthesis (81.6%. In-hospital mortality occurred in 27 (15.5% cases. Postoperatively, 25 (14.4% patients had low cardiac output and 17 (9.8% heart block. The actuarial survival rates for 10 and 15 years were 74.6±3.7% and 61.1±10.3%, respectively. In-hospital mortality was found to be associated with female gender, emergency operation, postoperative renal failure and low cardiac output. The long term mortality was significantly associated with mitral valve involvement. Male gender was found to be a significant risk factor for recurrence in the follow-up. Conclusion: Surgery for aortic valve endocarditis has significant mortality. Emergency operation, female gender, postoperative renal failure and low cardiac output are significant risk factors. Risk for recurrence and need for reoperation is low.

  20. Iatrogenic right coronary artery stenosis resulting from surgical tricuspid valve replacement: case report and review of the literature.

    Science.gov (United States)

    Morrissy, Stephen J; Atkins, Broadus Zane; Rogers, Jason H

    2014-12-01

    Iatrogenic injury to the right coronary artery (RCA) is a rare complication of tricuspid valve surgery. We herein describe the first-ever report of RCA injury related to tricuspid valve replacement surgery. A 38-year-old man with recurrent tricuspid endocarditis underwent redo tricuspid valve replacement by means of a minimally invasive right thoracotomy with a 32-mm St. Jude bioprosthetic valve. His post-operative course was complicated by pulseless ventricular tachycardia requiring CPR and defibrillation. Cardiac catheterization revealed a "kinked" stenotic distal RCA. The lesion was noted to be flow limiting by fractional flow reserve and was treated with two everolimus-eluting stents. The RCA runs in the atrioventricular groove and is susceptible to injury especially in the region of the posterior leaflet of the tricuspid valve, where the relationship of the tricuspid annulus to the RCA is most intimate. Repair of surgically induced coronary stenosis can be accomplished with percutaneous intervention. © 2014 Wiley Periodicals, Inc.

  1. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis: Acute and intermediate-term outcomes in a high volume institution

    Directory of Open Access Journals (Sweden)

    Anže Djordjević

    2017-03-01

    Full Text Available Background: We report our experience with transcatheter aortic valve implantation (TAVI in patients with bicuspid aortic valve (BAV stenosis.Methods: Perioperative and intermediate-term follow-up data were retrospectively analysed. All procedures were performed within the premises of an experienced high-volume TAVI centre.Results: Tirty-three consecutive BAV patients (age 55 to 87 years underwent TAVI. Mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE was 23,2 ± 19,3. Transapical Edwards Sapien® valve was implanted in the majority of patients (87.9 %. Nine patients (27.3 % required post-ballooning of the implanted valve for moderate to severe paravalvular leak, 3 patients (9 % required a second valve implantation for persistent severe paravalvular leak, and 2 (6 % required conversion to conventional surgery. Post-operative mild aortic regurgitation (AR was presented in 12 patients (36.4% and AR = 2 in 3 %. No AR > 2 was observed. Te device success rate according to the valve academic research consortium (VARC criteria was 82 %. Similar BAV anatomy, calcium distribution, type and size of implanted valve were noticed in patients with and without residual AR. Tere was no thirty-day mortality. Two-year estimated survival was 70 % (CI: 52.7–93.1 and was similar in patients with and without post-procedural residual paravalvular leak.Conclusions: TAVI in BAV stenosis is feasible but, even in experienced centres, is technically more challenging and is associated with a higher rate of post-dilatation, re-valving, and conversion to conventional surgery. Results should be re-tested in light of the recent introduction of second-generation TAVI prostheses.

  2. The influence of Marfans and bicuspid valves on outcomes following aortic valve reimplantation.

    Science.gov (United States)

    Martín, Carlos E; García Montero, Carlos; Serrano, Santiago-Fiz; González, Ana; Mingo, Susana; Moñivas, Vanessa; Centeno, Jorge; Forteza, Alberto

    2017-10-01

    We analyzed our early and midterm results with aortic valve reimplantation surgery to determine the influence of Marfan syndrome and bicuspid valves on outcomes with this technique. Between March 2004 and December 2015, 267 patients underwent aortic valve reimplantation operations. The mean diameter of the sinuses of Valsalva was 50 ± 3 mm and moderate/severe aortic regurgitation was present in 34.4% of these patients. A bicuspid aortic valve was present in 21% and 40% had Marfan syndrome. Overall 30-day mortality was 0.37% (1/267). Mean follow-up was 59.7 ± 38.7 months. Overall survival at 1, 3, and 5 years was 98 ± 8%, 98 ± 1%, and 94 ± 2%, respectively. Freedom from reoperation and aortic regurgitation >II was 99 ± 5%, 98 ± 8%, 96.7 ± 8%, and 99 ± 6%, 98 ± 1%, 98 ± 1%, respectively at 1, 3, and 5 years follow-up, with no differences between Marfan and bicuspid aortic valve groups. (p = 0.94 and p = 0.96, respectively). No endocarditis or thromboembolic complications were documented, and 93.6% of the patients did not receive any anticoagulation therapy. The reimplantation technique for aortic root aneurysms is associated with excellent clinical and functional outcomes at short and mid-term follow-up. © 2017 Wiley Periodicals, Inc.

  3. Video assisted right mini-thoracotomy for aortic valve replacement.

    Science.gov (United States)

    Johnson, Carl A; Melvin, Amber L; Lebow, Brandon F; Yap, Amanda; Knight, Peter A

    2018-01-01

    Aortic valve replacement through minimally invasive access is increasing. These procedures have several advantages over conventional sternotomy including decreased intensive care unit and hospital length of stay and decreased ventilation time. The right anterior mini-thoracotomy (RAM) approach is potentially attractive in that it completely spares the sternum leading to improved cosmesis, reduced blood loss, and improved patient satisfaction. However, this approach is underutilized due to anticipated technical challenges including difficulty with visualization and annular suture placement. We employ a camera and automated suturing technology for supra-annular valve implant. A RAM is performed via a 5 cm incision in the right second intercostal space with a camera port placed lateral to the incision. Peripheral venous cannulation is performed along with central arterial cannulation. Aortic cross clamp is placed through a 5 mm incision in the third interspace anterior to mid axillary line. Histidine tryptophan ketoglutarate (HTK) cardioplegia is administered. After aortic leaflet removal, annular and prosthetic sutures are placed with shafted instruments or with automated suturing technology. Aortic valve replacement can be performed safely through a RAM. The use of a camera and automated suturing technology facilitates this procedure, potentially enabling more surgeons to offer this less invasive approach to patients.

  4. The importance of echocardiography in transcatheter aortic valve implantation.

    Science.gov (United States)

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  5. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  6. Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.

    Science.gov (United States)

    Tavakoli, Reza; Auf der Maur, Christoph; Mueller, Xavier; Schläpfer, Reinhard; Jamshidi, Peiman; Daubeuf, François; Frossard, Nelly

    2015-02-03

    Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aortic xenograft implantation and compare the early clinical and midterm hemodynamic outcomes to those after aortic valve replacement with stented valves. We retrospectively compared the pre-operative characteristics of 180 consecutive patients who underwent full-root replacement with stentless aortic xenografts with those of 80 patients undergoing aortic valve replacement with stented valves. In subgroups presenting with aortic stenosis, we further analyzed the intra-operative data, early postoperative outcomes and mid-term regression of left ventricular mass index. Patients in the stentless group were younger (62.6 ± 13 vs. 70.3 ± 11.8 years, p regression of the left ventricular mass index in the stentless (p replacement can be performed without adversely affecting the early morbidity or mortality in patients operated on for aortic valve stenosis provided that the coronary ostia are not heavily calcified. The additional time necessary for the full-root stentless compared to the classical stented aortic valve replacement is therefore not detrimental to the early clinical outcomes and is largely rewarded in patients with aortic stenosis by lower transvalvular gradients at mid-term and a better regression of their left ventricular mass index.

  7. Leaflet reconstructive techniques for aortic valve repair.

    Science.gov (United States)

    Mazzitelli, Domenico; Stamm, Christof; Rankin, J Scott; Pfeiffer, Steffen; Fischlein, Theodor; Pirk, Jan; Choi, Yeong-Hoon; Detter, Christian; Kroll, Johannes; Beyersdorf, Friedhelm; Shrestha, Malakh; Schreiber, Christian; Lange, Rüdiger

    2014-12-01

    Refining leaflet reconstruction has become a primary issue in aortic valve repair. This descriptive analysis reviews leaflet pathology, repair techniques, and early results in a prospective regulatory trial of aortic valve repair. Sixty-five patients underwent valve repair for predominant moderate to severe aortic insufficiency (AI). The mean age was 63 ± 13 years, and 69% of the patients were male. Ascending aortic/root replacement was required in 62%. As a first step, ring annuloplasty was performed, and then leaflet repair included leaflet plication for prolapse, nodular unfolding, double pericardial patching of commissural defects or holes, complete pericardial leaflet replacement, leaflet extension, and Gore-Tex reinforcement. Leaflet techniques and causes of adverse outcomes were evaluated. The follow-up time was 2-years maximal and 0.9 years mean, with a survival of 97%. Eighty percent of patients required repair of leaflet defects: leaflet prolapse (52/65-80%), ruptured commissures (6/65-9%), leaflet holes (4/65-6%), and nodular retraction (6/65-9%). The average preoperative AI grade of 2.9 ± 0.8 fell to 0.7 ± 0.7 (p Gore-Tex reinforcements in 2 patients. Two patients with single pericardial leaflet replacements and all those with double pericardial reconstructions did well. Leaflet defects are common in patients with moderate to severe AI. Leaflet plication, nodular unfolding, and double pericardial patching performed well. Gore-Tex and leaflet extension seemed less satisfactory. Standardization and experience with leaflet reconstruction will be important for optimizing the outcomes of aortic valve repair. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Valve tissue characterization by magnetic resonance imaging in calcific aortic valve disease.

    Science.gov (United States)

    Le Ven, Florent; Tizón-Marcos, Helena; Fuchs, Christina; Mathieu, Patrick; Pibarot, Philippe; Larose, Eric

    2014-12-01

    Calcific aortic valve disease affects 10%-15% of the elderly population, causing considerable morbidity and mortality. There is no imaging technique that allows for the assessment of tissue composition of the valve in vivo. We thus investigated whether multiparametric magnetic resonance imaging (MRI) could characterize and quantify lipid, fibrous, and mineralized tissues within aortic valve (AV) cusps. AV leaflets were explanted from patients with severe aortic stenosis at the time of valve replacement surgery. Aortic cusps were imaged ex vivo using 1.5 T MRI using 3 gradient-echo sequences with T1, moderate T2, and proton density weightings (T1w, T2w, and PDw). Histopathologic analysis was performed on coregistered slices to identify and measure mineralized tissue, fibrous tissue, and lipid-rich tissue. Area and mean grey values were measured in all 3 weightings by standardized software. Four hundred ninety-two regions of interest from 30 AV leaflets were studied. Total leaflet surface and the areas of mineralized (P equation integrating the grey value data from all 3 weightings allowed multiparametric MRI to identify valve leaflet components with areas under the receiver operating characteristic curve of 0.92, 0.81, and 0.72, respectively. AV leaflet characteristics, including tissue composition, distribution, and area, may be successfully measured by multiparametric MRI with good to excellent accuracy. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  9. Deformation Differences between Tricuspid and Bicuspid Aortic Valves in Vitro

    Science.gov (United States)

    Szeto, Kai; Rodriguez-Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan C.

    2011-11-01

    It has been shown in clinical studies that patients with congenital bicuspid aortic valves (CBAVs) develop degenerative calcification of the leaflets at young ages compared to patients with the normal tricuspid aortic valves (TAVs). It has been hypothesized that the asymmetrical geometry of the leaflets in CBAVs, flow shear stresses (SS), disturbed flow, and excessive strain rate levels are possible causes for the early calcification and stenosis. Central to the validation of this hypothesis is the need to quantify the differences in strain rate levels between the BAVs and TAVs. We simulate the CBAVs by surgically stitching two of the leaflets of a porcine aortic valve together. To quantify strain differences, we performed in-vitro experiments in both trileaflet and bileaflet valves by tracking the motion of small ink dots marked on each leaflet surface. We then used phase-locked stereo photogrammetry to reconstruct at each instant of time the 3D surface of the leaflets and measure the strain rates in both radial and circumferential directions during the whole cardiac cycle. Our results indicate that the total strain rate of the simulated BAVs is about 15 to 20% higher than the normal leaflets of TAVs at systole. In the BAVs' case, the fused leaflet stretches radially up to 25% higher than the reference length. The excessive stretching in both directions in the fused leaflet results in large changes in the flow patterns and associated wall SS.

  10. Noninvasive assessment of filling pressure and left atrial pressure overload in severe aortic valve stenosis: relation to ventricular remodeling and clinical outcome after aortic valve replacement

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2011-01-01

    One of the hemodynamic consequences of aortic valve stenosis is pressure overload leading to left atrial dilatation. Left atrial size is a known risk factor providing prognostic information in several cardiac conditions. It is not known if this is also the case in patients with aortic valve...

  11. Postoperative Reverse Remodeling and Symptomatic Improvement in Normal-Flow Low-Gradient Aortic Stenosis After Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Carter-Storch, Rasmus; Møller, Jacob E; Christensen, Nicolaj L

    2017-01-01

    BACKGROUND: Severe aortic stenosis (AS) most often presents with reduced aortic valve area (benefit of aortic valve...... replacement (AVR) among NFLG patients is controversial. We compared the impact of NFLG condition on preoperative left ventricular (LV) remodeling and myocardial fibrosis and postoperative remodeling and symptomatic benefit. METHODS AND RESULTS: Eighty-seven consecutive patients with reduced aortic valve area...... and normal stroke volume index undergoing AVR underwent echocardiography, magnetic resonance imaging, a 6-minute walk test, and measurement of natriuretic peptides before and 1 year after AVR. Myocardial fibrosis was assessed from magnetic resonance imaging. Patients were stratified as NFLG or normal...

  12. Risks and Challenges of Surgery for Aortic Prosthetic Valve Endocarditis.

    Science.gov (United States)

    Grubitzsch, Herko; Tarar, Waharat; Claus, Benjamin; Gabbieri, Davide; Falk, Volkmar; Christ, Torsten

    2018-03-01

    Prosthetic valve endocarditis is the most severe form of infective endocarditis. This study assessed the risks and challenges of surgery for aortic prosthetic valve endocarditis. In total, 116 consecutive patients (98 males, age 65.2±12.7years), who underwent redo-surgery for active aortic prosthetic valve endocarditis between 2000 and 2014, were reviewed. Cox regression analysis was used to identify factors for aortic root destructions as well as for morbidity and mortality. Median follow-up was 3.8 years (0-13.9 years). Aortic root destructions (42 limited and 29 multiple lesions) were associated with early prosthetic valve endocarditis and delayed diagnosis (≥14 d), but not with mortality. There were 16 (13.8%) early (≤30 d) and 32 (27.6%) late (>30 days) deaths. Survival at 1, 5, and 10 years was 72±4.3%, 56±5.4%, and 46±6.4%, respectively. The cumulative incidence of death, reinfection, and reoperation was 19.0% at 30days and 36.2% at 1year. Delayed diagnosis, concomitant procedures, and EuroSCORE II >20% were predictors for early mortality and need for mechanical circulatory support, age >70years, and critical preoperative state were predictors for late mortality. In their absence, survival at 10 years was 70±8.4%. Reinfections and reoperations occurred more frequently if ≥1 risk factor for endocarditis and aortic root destructions were present. At 10 years, freedom from reinfection and reoperation was 89±4.2% and 91±4.0%. The risks of death, reinfection, and reoperation are significant within the first year after surgery for aortic prosthetic valve endocarditis. Early diagnosis and aortic root destructions are the most important challenges, but advanced age, critical preoperative state, and the need for mechanical circulatory support determine long-term survival. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B

  13. Acute type A aortic dissection: characteristics and outcomes comparing patients with bicuspid versus tricuspid aortic valve.

    Science.gov (United States)

    Etz, Christian D; von Aspern, Konstantin; Hoyer, Alexandro; Girrbach, Felix F; Leontyev, Sergey; Bakhtiary, Farhad; Misfeld, Martin; Mohr, Friedrich W

    2015-07-01

    The aim of this study is to investigate the clinical characteristics and postoperative outcome of patients with a bicuspid aortic valve (BAV) suffering acute dissection in comparison with their tricuspid peers. Between 1995 and 2011, 460 consecutive patients underwent emergency repair for acute type A aortic dissection. In 379 patients without connective tissue disease, the aortic valve morphology could clearly be specified (91.6% tricuspid and 8.4% bicuspid). At the time of dissection, patients with a bicuspid valve were younger (46.7 ± 13 vs 61.6 ± 12 years, P tricuspid valve (bicuspid: 31.3% vs tricuspid: 6.3%, P tricuspid valve patients (P tricuspid patients (P = 0.166). Hospital mortality was 20.3% and not significantly different between the two valve morphologies, even despite the younger age of bicuspid patients: 28.1% among bicuspids vs 19.6% among tricuspids (P = 0.255). Survival after discharge was 63.3% at 10 years for all patients. BAV patients had a significantly better survival with 100% at 10 years compared with 60.2% in tricuspid valve patients (P = 0.011). Mean follow-up among survivors was comparable for bicuspid and tricuspid patients (3.7 and 4.1 years, respectively). Patients with BAV have a distinctive dissection pattern with the entry tear frequently located in the aortic root and-despite their younger age-are subject to substantial hospital mortality. For bicuspid patients suffering from dissection, composite root replacement yields an excellent outcome equal to an age- and gender-matched normal population. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Longitudinal strain predicts left ventricular mass regression after aortic valve replacement for severe aortic stenosis and preserved left ventricular function.

    Science.gov (United States)

    Gelsomino, Sandro; Lucà, Fabiana; Parise, Orlando; Lorusso, Roberto; Rao, Carmelo Massimiliano; Vizzardi, Enrico; Gensini, Gian Franco; Maessen, Jos G

    2013-11-01

    We explored the influence of global longitudinal strain (GLS) measured with two-dimensional speckle-tracking echocardiography on left ventricular mass regression (LVMR) in patients with pure aortic stenosis (AS) and normal left ventricular function undergoing aortic valve replacement (AVR). The study population included 83 patients with severe AS (aortic valve area regression (all P regression in patients with pure AS undergoing AVR. Our findings must be confirmed by further larger studies.

  15. Risk Factors for Late Aortic Valve Dysfunction After the David V Valve-Sparing Root Replacement.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Guyton, Robert A; Chen, Edward P

    2017-11-01

    Valve-sparing root replacement (VSRR) is an established therapy for aortic root pathology. However, late aortic valve dysfunction requiring reoperation remains a primary concern of this procedure. This study examines risk factors for late aortic insufficiency (AI) and aortic stenosis (AS) after David V VSRR. A retrospective review from 2005 to 2015 at a US academic center identified 282 patients who underwent VSRR. Cox proportional hazards regression analysis was used to identify risk factors for late AI and AS after VSRR. The mean age was 46.4 years. Sixty-four patients (22.7%) had bicuspid valves, and 41 patients (14.5%) had Marfan syndrome. The incidence of reoperations was 27 (9.6%), and 42 cases (14.9%) presented with acute type A dissection. Operative mortality was 8 (2.8%). Seven-year survival was 90.9%. Seven-year cumulative incidence of reoperation, greater than 2+ AI and greater than moderate AS were 3.1%, 2.2%, and 0.8%, respectively. Multivariable analysis showed aortic root size 55 mm or larger (hazard ratio 3.44, 95% confidence interval: 1.27 to 9.29, p = 0.01) to be a risk factor for late AI whereas bicuspid valve (hazard ratio 16.07, 95% confidence interval: 3.12 to 82.68, p = 0.001) and cusp repair were found to be risk factors (hazard ratio 5.91, 95% confidence interval: 1.17 to 29.86, p = 0.03) for late AS. Valve-sparing root replacement can be performed with low operative risk and good overall long-term survival even in complex clinical settings. Durable valve function can be expected; however, aortic root size 55 cm or more, bicuspid valve anatomy, and cusp repair represent independent risk factors for late aortic valve dysfunction after these procedures. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Bioprosthetic Aortic Valve Endocarditis in Association with Enterococcus durans.

    Science.gov (United States)

    Fallavollita, Luca; Di Gioacchino, Lorena; Balestrini, Fabrizio

    2016-04-01

    Enterococci are common organisms associated with endocarditis, but infection by Enterococcus durans is very rare. To our knowledge, only 3 cases have been reported in the medical literature, and all 3 have involved native valves. Here we publish the first reported case (to our knowledge) of E. durans endocarditis in association with a bioprosthetic aortic valve. After the organism and its antibiotic susceptibility were identified, the 74-year-old male patient was treated successfully with teicoplanin and gentamicin, over a course of 6 weeks.

  17. Will Transcatheter Aortic Valve Replacement (TAVR be the Primary Therapy for Aortic Stenosis?

    Directory of Open Access Journals (Sweden)

    Jose F. Condado, MD, MS

    2016-05-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is increasingly used for the treatment of high or very high surgical risk patients with severe aortic stenosis (AS or failing surgical bioprosthesis (valve-in-valve, VIV-TAVR. In TAVR, the collapsed transcatheter heart valve (THV is introduced using the delivery system inserted from the femoral artery (preferred or other alternative accesses (transapical, transaortic, transcarotid, subclavian/transinnominate or transcaval. The delivery system is then advanced until coaxially aligned with the aortic annulus, where the THV is deployed. This procedure can be associated with complications such as access site injury (vascular complication, paravalvar leak, cerebrovascular events and conduction disturbances. However, the rapid acceptance and successes observed with TAVR have been made possible through careful patient selection, preprocedural planning (i.e. MDCT annular sizing, THV technology (i.e. new generation valves, and procedural techniques (i.e. minimalist TF-TAVR and alternative percutaneous access options, as well as a decrease in complications as TAVR experience grows. Though the results or ongoing clinical trials evaluating TAVR in intermediate surgical risk patients are pending, it is likely that TAVR will soon be approved for lower risk patients as well.

  18. Aortic valve-sparing operations in aortic root aneurysms: remodeling or reimplantation?

    Science.gov (United States)

    Rahnavardi, Mohammad; Yan, Tristan D; Bannon, Paul G; Wilson, Michael K

    2011-08-01

    A best evidence topic was written according to a structured protocol. The question addressed was whether the reimplantation (David) technique or the remodeling (Yacoub) technique provides the optimum event free survival in patients with an aortic root aneurysm suitable for an aortic valve-sparing operation. In total, 392 papers were found using the reported search criteria, of which 14 papers provided the best evidence to answer the clinical question. A total of 1338 patients (Yacoub technique in 606 and David technique in 732) from 13 centres were included. In most series, cardiopulmonary bypass time and aortic cross-clamp time were longer for the David technique compared to the Yacoub technique. Early mortality was comparable between the two techniques (0-6.9% for the Yacoub technique and 0-6% for the David technique). There is a tendency for a higher freedom from significant long-term aortic insufficiency in the David group than the Yacoub group, which does not necessarily result in a higher reoperation rate in the Yacoub group. In the largest series reported, freedom from a moderate-to-severe aortic insufficiency at 12 years was 82.6 ± 6.2% in the Yacoub and 91.0 ± 3.8% in the David group (P=0.035). Freedom from reoperation at the same time point was 90.4 ± 4.7% in the Yacoub group and 97.4 ± 2.2% in the David group (P=0.09). In another series, freedom from reoperation at a follow-up time of about four years was 89 ± 4% in the Yacoub group and 98 ± 2% in the David group. Although some authors merely preferred the Yacoub technique for a bicuspid aortic valve, the accumulated evidence in the current review indicates comparable results for both techniques in a bicuspid aortic valve. Current evidence is in favour of the David rather than the Yacoub technique in pathologies such as Marfan syndrome, acute type A aortic dissection, and excessive annular dilatation that may impair aortic root integrity. Careful selection of patients for each technique and

  19. Fluid Dynamics of Thrombosis in Transcatheter Aortic Valves

    Science.gov (United States)

    Seo, Jung Hee; Zhu, Chi; Dou, Zhongwang; Resar, Jon; Mittal, Rajat

    2017-11-01

    Transcatheter aortic valve replacement (TAVR) with bioprosthetic valves (BPV) has become highly prevalent in recent years. While one advantage of BPVs over mechanical ones is the lower incidence of valve thrombosis, recent clinical studies have suggested a higher than expected incidence of subclinical bioprosthetic valve thrombosis (BVT). Many factors that might affect the transvalvular hemodynamics including the valve position, orientation, stent, and interaction with the coronary flow, have been suggested, but the casual mechanisms of valve thrombosis are still unknown. In the present study, the hemodynamics associated with the formation of BVT is investigated using a novel, coupled flow-structure-biochemical computational modeling. A reduced degree of freedom, fluid-structure-interaction model is proposed for the efficient simulation of the hemodynamics and leaflet dynamics in the BPVs. Simple models to take into account the effects of the stent and coronary flows have also been developed. Simulations are performed for canonical models of BPVs in the aorta in various configurations and the results are examined to provide insights into the mechanisms for valve thrombosis. Supported by the NSF Grants IIS-1344772, CBET-1511200 and NSF XSEDE Grant TG-CTS100002.

  20. Coronary artery disease, revascularization, and clinical outcomes in transcatheter aortic valve replacement

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Lønborg, Jacob

    2018-01-01

    Transcatheter aortic valve replacement (TAVR) has become an established therapeutic option for patients with symptomatic, severe aortic stenosis. The optimal treatment strategy for concomitant coronary artery disease (CAD) has not been tested prospectively in a randomized clinical trial. This study...

  1. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    be atypical causing a delay in the diagnosis and treatment. The management is also complicated by their comorbidities, and surgical treatment may not be feasible leading to a significant morbidity and mortality. We describe a case of an 85-year-old man with TAVI prosthetic valve endocarditis successfully...

  2. Increased risk of aortic valve stenosis in patients with psoriasis

    DEFF Research Database (Denmark)

    Khalid, Usman; Ahlehoff, Ole; Gislason, Gunnar Hilmar

    2015-01-01

    AIM: Psoriasis is a chronic inflammatory disease associated with increased risk of cardiovascular disease including atherosclerosis. The pathogenesis of aortic valve stenosis (AS) also includes an inflammatory component. We therefore investigated the risk of AS in patients with psoriasis compared...... with mild and severe disease, respectively. CONCLUSION: In a nationwide cohort, psoriasis was associated with a disease severity-dependent increased risk of AS. The mechanisms underlying this novel finding require further study....

  3. Intermittent acute aortic valve regurgitation: A case report of a prosthetic valve dysfunction

    NARCIS (Netherlands)

    S.E. Karagiannis (Stefanos); G. Karatasakis (George); K. Spargias (Konstantinos); L. Louka; D. Poldermans (Don); D.V. Cokkinos (Dennis)

    2008-01-01

    textabstractComplications of any mechanical prosthesis include thrombus or pannus formation. In our case report we demonstrate that prosthetic aortic valve regurgitation due to pannus formation may be intermittent and non-cyclic in pattern and therefore not obvious at the time of original clinical

  4. [Selection of patients for transcatheter aortic valve implantation].

    Science.gov (United States)

    Tron, Christophe; Godin, Matthieu; Litzler, Pierre-Yves; Bauer, Fabrice; Caudron, Jérome; Dacher, Jean-Nicolas; Borz, Bogdan; Canville, Alexandre; Kurtz, Baptiste; Bessou, Jean-Paul; Cribier, Alain; Eltchaninoff, Hélène

    2012-06-01

    A good selection of patients is a crucial step before transcatheter aortic valve implantation (TAVI) in order to select the good indications and choose the access route. TAVI should be considered only in patients with symptomatic severe aortic stenosis and either contraindication or high surgical risk. Indication for TAVI should be discussed in a multidisciplinary team meeting. Echocardiography and/or CT scan are mandatory to evaluate the aortic annulus size and select the good prosthesis size. The possibility of transfemoral implantation is evaluated by angiography and CT scan, and based on the arterial diameters, but also on the presence of tortuosities and arterial calcifications. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Aortic valve sclerosis is associated with lower serum adiponectin levels.

    Science.gov (United States)

    Çabuk, Gizem; Guray, Umit; Kafes, Habibe; Guray, Yesim; Cabuk, Ali Kemal; Bayir, Pinar T; Asarcikli, Lale D

    2015-06-01

    The sclerotic lesions of the aortic valve share common features with atherosclerosis. An anti-inflammatory protein, adiponectin, seems to have a protective effect on the cardiovascular system. The goal of our study is to determine adiponectin levels in patients with aortic sclerosis and to compare these values with the control group with similar age and cardiovascular risk profile. Sixty-eight patients with aortic sclerosis and 40 controls were included. Serum adiponectin levels were measured by solid-phase enzyme-linked immunosorbent assay. There were no significant differences regarding age, sex and other cardiovascular risk factors between groups. Also, mean body mass index values were similar. The rate of mitral annular calcification and left ventricular hypertrophy were significantly higher in patients with aortic sclerosis. Among laboratory variables, high-sensitive C-reactive protein (hsCRP) levels were significantly higher in patients with aortic sclerosis than in those without (4.0 ± 2.9 vs. 2.9 ± 2.3 mg/dl, P = 0.04). Adiponectin levels were found to be significantly lower in aortic sclerosis group than in controls (9.7 ± 4.4 vs. 11.7 ± 4.9 μg/ml, P = 0.034). In the whole group, adiponectin levels were significantly correlated with BMI (r = -0.22, P = 0.02), white blood cell count (r = -0.2, P = 0.03), hsCRP (r = -0.25, P = 0.008), total cholesterol (r = -0.18, P = 0.05), high-density lipoprotein (HDL) cholesterol (r = 0.31, P = 0.001) and triglyceride (r = -0.36, P sclerosis, serum adiponectin levels were significantly lower compared with those with normal aortic valves. Our findings suggested that adiponectin might play a role in the progression of degenerative aortic valve disease.

  6. Valve Sparing Aortic Root Replacement in Children with Loeys-Dietz Syndrome

    Directory of Open Access Journals (Sweden)

    Hyung-Tae Sim

    2015-08-01

    Full Text Available Loeys-Dietz syndrome (LDS is an autosomal dominant connective tissue disorder that is characterized by aggressive arterial and aortic disease, often involving the formation of aortic aneurysms. We describe the cases of two children with LDS who were diagnosed with aortic root aneurysms and successfully treated by valve-sparing aortic root replacement (VSRR with a Valsalva graft. VSRR is a safe and suitable operation for children that avoids prosthetic valve replacement.

  7. Valve-sparing aortic root replacement in Marfan syndrome.

    Science.gov (United States)

    Cameron, Duke E; Vricella, Luca A

    2005-01-01

    Marfan syndrome is the most common inherited connective tissue disorder, affecting approximately 1 in 10,000 live births. The cardinal features of Marfan syndrome are the abnormalities of the skeleton (tall stature, arachnodactyly, and joint hyperelasticity), eye (lens subluxation), and aorta (root aneurysm with proclivity toward rupture and dissection). Aortic catastrophe accounts for most of the premature mortality among Marfan patients, a risk that climbs steeply during adolescence and results in death of half of Marfan patients by the age of 40 years. Most of the improvement in life expectancy that has been achieved in Marfan syndrome is attributable to early recognition of aortic root aneurysms and prophylactic replacement with composite grafts (mechanical valve prostheses within Dacron conduits) before rupture or dissection occurs. Despite the excellent early and late results with composite grafts, there has been growing interest in operative procedures that replace the sinuses but preserve the aortic valve leaflets, to avoid anticoagulation and minimize the risk of prosthesis-related endocarditis. These procedures are still in evolution and late results are not yet known, but as with mitral repair in the setting of myxomatous disease, valve-sparing procedures in Marfan syndrome have weathered a storm of initial criticism and skepticism and are steadily gaining acceptance.

  8. Aortic valve area assessed with 320-detector computed tomography

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig

    2014-01-01

    To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVA......(MDCT)) and by the continuity equation with TTE (AVA(TTE)). To generate a reference AVA (AVA(REF)) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVA(REF) was used...... as the reference to compare both measures against, since it bypasses the assumption of LVOT being circular in the continuity equation and the potential placement error of PW Doppler in the LVOT. The mean (±SD) age of the patients was 71 (±9) years, 113 (67%) were males. Mean AVA(TTE) was 0.93 (±0.33) cm(2), mean...

  9. Mechanisms of recurrent aortic regurgitation after aortic valve repair: predictive value of intraoperative transesophageal echocardiography.

    Science.gov (United States)

    le Polain de Waroux, Jean-Benoît; Pouleur, Anne-Catherine; Robert, Annie; Pasquet, Agnès; Gerber, Bernhard L; Noirhomme, Philippe; El Khoury, Gébrine; Vanoverschelde, Jean-Louis J

    2009-08-01

    The aim of the present study was to examine the intraoperative echocardiographic features associated with recurrent severe aortic regurgitation (AR) after an aortic valve repair surgery. Surgical valve repair for AR has significant advantages over valve replacement, but little is known about the predictors and mechanisms of its failure. We blindly reviewed all clinical, pre-operative, intraoperative, and follow-up transesophageal echocardiographic data of 186 consecutive patients who underwent valve repair for AR during a 10-year period and in whom intraoperative and follow-up echo data were available. After a median follow-up duration of 18 months, 41 patients had recurrent 3+ AR, 23 patients presented with residual 1+ to 2+ AR, and 122 had no or trivial AR. In patients with recurrent 3+ AR, the cause of recurrent AR was the rupture of a pericardial patch in 3 patients, a residual cusp prolapse in 26 patients, a restrictive cusp motion in 9 patients, an aortic dissection in 2 patients, and an infective endocarditis in 1 patient. Pre-operatively, all 3 groups were similar for aortic root dimensions and prevalence of bicuspid valve (overall 37%). Patients with recurrent AR were more likely to display Marfan syndrome or type 3 dysfunction pre-operatively. At the opposite end, patients with continent AR repair at follow-up were more likely to have type 2 dysfunction pre-operatively. After cardiopulmonary bypass, a shorter coaptation length, the degree of cusp billowing, a lower level of coaptation (relative to the annulus), a larger diameter of the aortic annulus and the sino-tubular junction, the presence of a residual AR, and the width of its vena contracta were associated with the presence of AR at follow-up. Multivariate Cox analysis identified a shorter coaptation length (odds ratio [OR]: 0.8, p = 0.05), a coaptation occurring below the level of the aortic annulus (OR: 7.9, p < 0.01), a larger aortic annulus (OR: 1.2, p = 0.01), and residual aortic regurgitation

  10. A Typical Immune T/B Subset Profile Characterizes Bicuspid Aortic Valve: In an Old Status?

    Directory of Open Access Journals (Sweden)

    Carmela R. Balistreri

    2018-01-01

    Full Text Available Bicuspid valve disease is associated with the development of thoracic aortic aneurysm. The molecular mechanisms underlying this association still need to be clarified. Here, we evaluated the circulating levels of T and B lymphocyte subsets associated with the development of vascular diseases in patients with bicuspid aortic valve or tricuspid aortic valve with and without thoracic aortic aneurysm. We unveiled that the circulating levels of the MAIT, CD4+IL−17A+, and NKT T cell subsets were significantly reduced in bicuspid valve disease cases, when compared to tricuspid aortic valve cases in either the presence or the absence of thoracic aortic aneurysm. Among patients with tricuspid aortic valve, these cells were higher in those also affected by thoracic aortic aneurysm. Similar data were obtained by examining CD19+ B cells, naïve B cells (IgD+CD27−, memory unswitched B cells (IgD+CD27+, memory switched B cells (IgD−CD27+, and double-negative B cells (DN (IgD−CD27−. These cells resulted to be lower in subjects with bicuspid valve disease with respect to patients with tricuspid aortic valve. In whole, our data indicate that patients with bicuspid valve disease show a quantitative reduction of T and B lymphocyte cell subsets. Future studies are encouraged to understand the molecular mechanisms underlying this observation and its pathophysiological significance.

  11. Quality and Safety in Health Care, Part XXX: Transcatheter Aortic Valve Therapy.

    Science.gov (United States)

    Harolds, Jay A

    2017-12-01

    Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery.

  12. Increased hsCRP is associated with higher risk of aortic valve replacement in patients with aortic stenosis

    DEFF Research Database (Denmark)

    Blyme, Adam; Nielsen, Olav W.; Asferg, Camilla

    2016-01-01

    Objective To investigate relations between inflammation and aortic valve stenosis (AS) by measuring high-sensitivity C-reactive protein, at baseline (hsCRP0) and after 1 year (hsCRP1) and exploring associations with aortic valve replacement (AVR). Design We examined 1423 patients from the Simvast......Objective To investigate relations between inflammation and aortic valve stenosis (AS) by measuring high-sensitivity C-reactive protein, at baseline (hsCRP0) and after 1 year (hsCRP1) and exploring associations with aortic valve replacement (AVR). Design We examined 1423 patients from...... the Simvastatin and Ezetimibe in Aortic Stenosis study. Results During first year of treatment, hsCRP was reduced both in patients later receiving AVR (2.3 [0.9–4.9] to 1.8 [0.8–5.4] mg/l, p regression analyses, hsCRP1...

  13. Subclinical leaflet thrombosis after transcatheter aortic valve implantation.

    Science.gov (United States)

    Nakatani, Satoshi

    2017-12-01

    Although clinically significant valve thrombosis after transcatheter aortic valve implantation (TAVI) is rare, the incidence of subclinical leaflet thrombosis has been reported to be up to about 10%-15%. It is mostly found 1-3 months after procedure in any type of transcatheter heart valve. Leaflet thrombosis is detected by high-resolution CT in the form of limited valve opening/closure and hypoattenuated leaflet thickening. Transthoracic or transesophageal echocardiography is capable of detecting limitations of valve motion, leaflet thickening, increased flow velocity across the valve. However, CT seems to be more sensitive than echocardiography to detect leaflet thrombosis. It can occur under dual antiplatelet therapy with aspirin and a thienopyridine but rarely occurs with anticoagulation with a vitamin K antagonist. A vitamin K antagonist is also helpful to resolve leaflet thrombosis. Several studies are ongoing to determine the effect of new oral anticoagulants (NOACs) in preventing major cardiovascular events. They will also provide useful information on whether NOACs prevent leaflet thrombosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Circulating matrix metalloproteinase patterns in association with aortic dilatation in bicuspid aortic valve patients with isolated severe aortic stenosis.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Dong, Lili; Wang, Chunsheng; Wang, Xiaolin; Shu, Xianhong

    2016-02-01

    Bicuspid aortic valve (BAV) exhibits a clinical incline toward aortopathy, in which aberrant tensile and shear stress generated by BAV can induce differential expression of matrix metalloproteinases (MMPs) and their endogenous tissue inhibitors (TIMPs). Whether stenotic BAV, which exhibits additional eccentric high-velocity flow jet upon ascending aorta and further worsens circumferential systolic wall shear stress than BAV with echocardiographically normal aortic valve, can lead to unique plasma MMP/TIMP patterns is still unknown. According to their valvulopathy and aortic dilatation status, 93 BAV patients were included in the present study. Group A (n = 37) and B (n = 28) comprised severely stenotic patients with or without ascending aorta dilatation; Group C (n = 12) and D (n = 16) comprised echocardiographically normal BAV patients with or without ascending aorta dilatation. Plasma MMP/TIMP levels (MMP-1, -2, -3, -8, -9, -10, -13 and TIMP-1, -2, -4) were determined via a multiplex ELISA detection system in a single procedure. Among patients with isolated severe aortic stenosis, plasma levels of MMP-2 and -9 were significantly elevated when ascending aortic dilatation was present (p = 0.001 and p = 0.002, respectively). MMP-2, however, remained as the single elevated plasma component among echocardiographically normal BAV patients with dilated ascending aorta (p = 0.027). Multivariate analysis revealed that MMP-2 and MMP-9 could both serve as independent risk factor for aortic dilatation in the case of isolated severe stenosis (p = 0.003 and p = 0.001, respectively), and MMP-2 in echocardiographically normal patients (p = 0.002). In conclusion, BAV patients with isolated severe aortic stenosis demonstrated a distinct plasma MMP/TIMP pattern, which might be utilized as circulating biomarkers for early detection of aortic dilatation.

  15. Computed tomography characteristics of the aortic valve and the geometry of SAPIEN 3 transcatheter heart valve in patients with bicuspid aortic valve disease.

    Science.gov (United States)

    Kawamori, Hiroyuki; Yoon, Sung-Han; Chakravarty, Tarun; Maeno, Yoshio; Kashif, Mohammad; Israr, Sharjeel; Abramowitz, Yigal; Mangat, Geeteshwar; Miyasaka, Masaki; Rami, Tanya; Kazuno, Yoshio; Takahashi, Nobuyuki; Jilaihawi, Hasan; Nakamura, Mamoo; Cheng, Wen; Friedman, John; Berman, Daniel; Sharma, Rahul; Makkar, Raj R

    2018-01-05

    We assessed the geometry of transcatheter heart valve (THV) and valve function associated with SAPIEN 3 implantation in patients with bicuspid aortic valve (BAV) stenosis. We included 280 consecutive patients who had a contrast computed tomography (CT) before and after transcatheter aortic valve implantation (TAVI) in our institution. Each THV was assessed by CT at five cross-sectional levels: inflow, annulus, mid, sinus, and outflow. The geometry of THV was assessed for eccentricity (1 - minimum diameter/maximum diameter) and expansion (CT derived external valve area/nominal external valve area). CT measurements and transthoracic echocardiogram data were compared between BAV and tricuspid aortic valve (TAV). Among 280 patients, 41 patients were diagnosed as BAV. Compared to TAV, BAV was associated with lower expansion at mid-level, sinus-level, and outflow-level (mid 94.1 ± 6.8% vs. 98.1 ± 7.8%; P = 0.002, sinus 95.9 ± 7.2% vs. 101.6 ± 8.5%; P 4.0-11.4); P < 0.001, and outflow 2.5% (1.3-4.3) vs. 4.9% (2.2-7.5); P < 0.001]. There were no differences in frequency of paravalvular leak ≥ moderate and mean post-procedural gradient between BAV and TAV. BAV patients have greater THV eccentricity at all levels and lower THV expansion at mid, sinus, and outflow levels than the TAV patients. There were no differences in parameters of valve function between BAV and TAV patients. Despite the observed geometrical differences, TAVI with SAPIEN 3 in BAV patients allows for feasible valve function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

  16. Bicuspid Aortic Valve: Unresolved Issues and Role of Imaging Specialists

    Science.gov (United States)

    2015-01-01

    Bicuspid aortic valve (BAV) is the most common congenital heart disease with marked heterogeneity in many aspects. Fusion patterns of the aortic cusp are quite variable with different type and severity of valvular dysfunction. Moreover, non-valvular cardiovascular abnormalities are associated with BAV. Among them, aortic aneurysm/dissection is the most serious clinical condition with variable patterns of segmental aortic dilatation. Potential association between BAV phenotype and valvulopathy or aortopathy has been suggested, but needs to be tested further. A lack of long-term outcome data at this moment is responsible for unresolved debate regarding appropriate management of patients with BAV, specifically to prevent development of aortic dissection. Long-term follow-up data of a well-characterized cohort or registry based on standardized classification of BAV phenotype and aortopathy are necessary for evidence-based medical practice. Advanced imaging techniques such as computed tomography or magnetic resonance imaging offer better opportunities for accurate phenotype classification and imaging specialists should play a central role to establish a collaborative multicenter cohort or registry. PMID:25883749

  17. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  18. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Science.gov (United States)

    Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-01-01

    Summary In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR). Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. PMID:27249815

  19. Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA

    NARCIS (Netherlands)

    Baan, J.; Yong, Z. Y.; Koch, K. T.; Henriques, J. P. S.; Bouma, B. J.; de Hert, S. G.; van der Meulen, J.; Tijssen, J. G. P.; Piek, J. J.; de Mol, B. A. J. M.

    2010-01-01

    Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the

  20. Cardiac energetics analysis after aortic valve replacement with 16-mm ATS mechanical valve.

    Science.gov (United States)

    Ushijima, Tomoki; Tanoue, Yoshihisa; Uchida, Takayuki; Matsuyama, Sho; Matsumoto, Takashi; Tominaga, Ryuji

    2014-09-01

    The 16-mm ATS mechanical valve is one of the smallest prosthetic valves used for aortic valve replacement (AVR) in patients with a very small aortic annulus, and its clinical outcomes are reportedly satisfactory. Here, we analyzed the left ventricular (LV) performance after AVR with the 16-mm ATS mechanical valve, based on the concept of cardiac energetics analysis. Eleven patients who underwent AVR with the 16-mm ATS mechanical valve were enrolled in this study. All underwent echocardiographic examination at three time points: before AVR, approximately 1 month after AVR, and approximately 1 year after AVR. LV contractility (end-systolic elastance [Ees]), afterload (effective arterial elastance [Ea]), and efficiency (ventriculoarterial coupling [Ea/Ees] and the stroke work to pressure-volume area ratio [SW/PVA]) were noninvasively measured by echocardiographic data and blood pressure measurement. Ees transiently decreased after AVR and then recovered to the pre-AVR level at the one-year follow-up. Ea significantly decreased in a stepwise manner. Consequently, Ea/Ees and SW/PVA were also significantly improved at the one-year follow-up compared with those before AVR. The midterm LV performance after AVR with the 16-mm ATS mechanical valve was satisfactory. AVR with the 16-mm ATS mechanical valve is validated as an effective treatment for patients with a very small aortic annulus. The cardiac energetics variables, coupling with the conventional hemodynamic variables, can contribute to a better understanding of the patients' clinical conditions, and those may serve as promising indices of the cardiac function.

  1. Limited versus full sternotomy for aortic valve replacement.

    Science.gov (United States)

    Kirmani, Bilal H; Jones, Sion G; Malaisrie, S C; Chung, Darryl A; Williams, Richard Jnn

    2017-04-10

    Aortic valve disease is a common condition that is easily treatable with cardiac surgery. This is conventionally performed by opening the sternum longitudinally down the centre ("median sternotomy") and replacing the valve under cardiopulmonary bypass. Median sternotomy is generally well tolerated, but as less invasive options have become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access has raised safety concerns with regards to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. We performed searches of CENTRAL, MEDLINE, Embase, clinical trials registries, and manufacturers' websites from inception to July 2016, with no language limitations. We reviewed references of identified papers to identify any further studies of relevance. Randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, trans-apical, trans-femoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. Two review authors independently assessed trial papers to extract data

  2. Aortic root reconstruction by aortic valve-sparing operation (David type I reimplantation) in Marfan syndrome accompanied by annuloaortic ectasia and acute type-A aortic dissection.

    Science.gov (United States)

    Inamura, Shunichi; Furuya, Hidekazu; Yagi, Kentarou; Ikeya, Eriko; Yamaguchi, Masaomi; Fujimura, Takabumi; Kanabuchi, Kazuo

    2006-09-20

    To reconstruct the aortic root for aneurysm of the ascending aorta accompanied by aortic regurgitation, annuloaortic ectasia (AAE) and acute type-A dissection with root destruction, the Bentall operation using a prosthetic valve still is the standard procedure today. Valve-sparing procedures have actively been used for aortic root lesions, and have also been attempted in aortic root reconstruction for Marfan syndrome which may have abnormalities in the valve leaflets. We conducted a valve-sparing procedure in a female patient with Marfan syndrome who had AAE accompanied by type-A acute aortic dissection. The patient was a 37-year-old woman complaining of severe pain from the chest to the back. The limbs were long, and funnel breast was observed. Diastolic murmurs were heard. On chest computed tomography, a dissection cavity was present from the ascending aorta to the left common iliac artery, and the root dilated to 55 mm. Grade II aortic regurgitation was observed on ultrasound cardiography. Regarding her family history, her father had died suddenly at 54 years of age. She was diagnosed with type-A acute dissection concurrent with Marfan syndrome and AAE. The structure of the aortic valve was normal, and root reconstruction by a valve-sparing operation and total replacement of the aortic arch was conducted. On postoperative ultrasound cardiography, the aortic regurgitation was within the allowable range, and the shortterm postoperative results were good.

  3. Association of warfarin therapy duration after bioprosthetic aortic valve replacement with risk of mortality, thromboembolic complications, and bleeding

    DEFF Research Database (Denmark)

    Mérie, Charlotte; Køber, Lars; Skov Olsen, Peter

    2012-01-01

    The need for anticoagulation after surgical aortic valve replacement (AVR) with biological prostheses is not well examined.......The need for anticoagulation after surgical aortic valve replacement (AVR) with biological prostheses is not well examined....

  4. Fused aortic valve without an elliptical-shaped systolic orifice in patients with severe aortic stenosis: cardiac computed tomography is useful for differentiation between bicuspid aortic valve with raphe and tricuspid aortic valve with commissural fusion

    Energy Technology Data Exchange (ETDEWEB)

    Bak, So Hyeon; Ko, Sung Min [Konkuk University School of Medicine, Departments of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Song, Meong Gun; Shin, Je Kyoun; Chee, Hyun Kun; Kim, Jun Suk [Konkuk University School of Medicine, Departments of Thoracic Surgery, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2015-04-01

    The objective is to determine cardiac computed tomography (CCT) features capable of differentiating between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) in severe aortic stenosis (AS) patients with fused cusp and without elliptical-shaped systolic orifices. We retrospectively enrolled 53 patients who had severe AS with fused cusps and without an elliptical-shaped systolic orifice on CCT and who had undergone surgery. CCT features were analyzed using: (1) aortic valve findings including cusp size, cusp area, opening shape, midline calcification, fusion length, calcium volume score, and calcium grade; (2) diameters of ascending and descending aorta, and main pulmonary artery; and (3) rheumatic mitral valve findings. The variables were evaluated using univariate and multivariate logistic regression analyses. At surgery, 19 patients had BAV and 34 had TAV. CCT features including uneven cusp size, uneven cusp area, round-shaped systolic orifice, longer cusp fusion, and dilatation of ascending aorta were significantly associated with BAV (P < 0.05). In particular, fusion length (OR, 1.76; P = 0.001), uneven cusp area (OR, 10.46; P = 0.012), and midline calcification (OR, 0.08; P = 0.013) were strongly associated with BAV. CCT provides diagnostic clues that helps differentiate between BAV with raphe and TAV with commissural fusion in patients with severe AS. (orig.)

  5. Aorta measurements are heritable and influenced by bicuspid aortic valve

    Directory of Open Access Journals (Sweden)

    Lisa J Martin

    2011-09-01

    Full Text Available Abstract: Word Count 266, 1609 charactersObjectives: To determine whether the contributions of genetics and bicuspid aortic valve (BAV independently influence aortic (Ao dimensions.Background: Ao dilation is a risk factor for aneurysm, dissection, and sudden cardiac death. Frequent association of BAV with Ao dilation implicates a common underlying defect possibly due to genetic factors. Methods: Families enriched for BAV underwent standardized transthoracic echocardiography. In addition to BAV status, echocardiographic measures of Ao (annulus to descending Ao, pulmonary artery and mitral valve annulus diameters were obtained. Using variance components analysis, heritability was estimated with and without BAV status. Additionally, bivariate genetic analyses between Ao dimensions and BAV were performed.Results: Our cohort was obtained from 209 families enriched for BAV. After adjusting for age, body surface area and sex, individuals with BAV had a statistically significant increase in all echocardiographic measurements (p < 0.006 except descending Ao and mitral valve annulus. Individuals with BAV were at greater odds of having Ao dilation (OR = 4.44, 95% CI 2.93 – 6.72 than family members without BAV. All echocardiographic measurements exhibited moderate to strong heritability (0.25 to 0.53, and these estimates were not influenced by inclusion of BAV as a covariate. Bivariate genetic analyses supported that the genetic correlation between BAV and echo measures were not significantly different from zero.Conclusions: We show for the first time that echocardiographic measurements of Ao, pulmonary artery and mitral valve annulus diameters are quantitative traits that exhibit significant heritability. In addition, our results suggest the presence of BAV independently influences the proximal Ao and pulmonary artery measures but not those in the descending Ao or mitral valve annulus.

  6. Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement

    DEFF Research Database (Denmark)

    Lund, Ole; Dorup, Inge; Emmertsen, Kristian

    2005-01-01

    OBJECTIVES: Size mismatch and impaired left ventricular function have been shown to determine the hemodynamic function of the standard St. Jude bileaflet disc valve early after aortic valve replacement (AVR). We aimed to analyse St. Jude valve hemodynamic function and its clinical impact in the s......OBJECTIVES: Size mismatch and impaired left ventricular function have been shown to determine the hemodynamic function of the standard St. Jude bileaflet disc valve early after aortic valve replacement (AVR). We aimed to analyse St. Jude valve hemodynamic function and its clinical impact......Hg. In a multilinear regression analysis GOA indexed for LVEDD, hypertension, and LVEF were independently related to peak gradient. CONCLUSION: High gradients of the standard St. Jude bileaflet disc valve 10 years after AVR was primarily related to systemic hypertension and mismatch between valve and left ventricular...

  7. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Andrew K. Roy

    2016-01-01

    Full Text Available Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS. Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74, which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure.

  8. Sex differences in aortic valve calcification measured by multidetector computed tomography in aortic stenosis.

    Science.gov (United States)

    Aggarwal, Shivani R; Clavel, Marie-Annick; Messika-Zeitoun, David; Cueff, Caroline; Malouf, Joseph; Araoz, Philip A; Mankad, Rekha; Michelena, Hector; Vahanian, Alec; Enriquez-Sarano, Maurice

    2013-01-01

    Aortic valve calcification (AVC) is the intrinsic mechanism of valvular obstruction leading to aortic stenosis (AS) and is measurable by multidetector computed tomography. The link between sex and AS is controversial and that with AVC is unknown. We prospectively performed multidetector computed tomography in 665 patients with AS (aortic valve area, 1.05±0.35 cm(2); mean gradient, 39±19 mm Hg) to measure AVC and to assess the impact of sex on the AVC-AS severity link in men and women. AS severity was comparable between women and men (peak aortic jet velocity: 4.05±0.99 versus 3.93±0.91 m/s, P=0.11; aortic valve area index: 0.55±0.20 versus 0.56±0.18 cm(2)/m(2); P=0.46). Conversely, AVC load was lower in women versus men (1703±1321 versus 2694±1628 arbitrary units; PAVC load were much greater in men than in women (odds ratio, 5.07; PAVC showed good associations with hemodynamic AS severity in men and women (all r>0.67; PAVC load, absolute or indexed, was higher in men versus women (all P≤0.01). In this large AS population, women incurred similar AS severity than men for lower AVC loads, even after indexing for their smaller body size. Hence, the relationship between valvular calcification process and AS severity differs in women and men, warranting further pathophysiological inquiry. For AS severity diagnostic purposes, interpretation of AVC load should be different in men and in women.

  9. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.

  10. Pulsatile cardiopulmonary bypass and renal function in elderly patients undergoing aortic valve surgery

    NARCIS (Netherlands)

    Milano, Aldo Domenico; Dodonov, Mikhail; Van Oeveren, Willem; Onorati, Francesco; Gu, Y. John; Tessari, Maddalena; Menon, Tiziano; Gottin, Leonardo; Faggian, Giuseppe

    OBJECTIVES: To evaluate if pulsatile cardiopulmonary bypass (CPB) has any protective influence on renal function in elderly patients undergoing aortic valve replacement (AVR). METHODS: Forty-six patients (>= 75 years old) with aortic valve stenosis underwent AVR with either pulsatile perfusion (PP)

  11. Left ventricular mass regression after porcine versus bovine aortic valve replacement: a randomized comparison.

    Science.gov (United States)

    Suri, Rakesh M; Zehr, Kenton J; Sundt, Thoralf M; Dearani, Joseph A; Daly, Richard C; Oh, Jae K; Schaff, Hartzell V

    2009-10-01

    It is unclear whether small differences in transprosthetic gradient between porcine and bovine biologic aortic valves translate into improved regression of left ventricular (LV) hypertrophy after aortic valve replacement. We investigated transprosthetic gradient, aortic valve orifice area, and LV mass in patients randomized to aortic valve replacement with either the Medtronic Mosaic (MM) porcine or an Edwards Perimount (EP) bovine pericardial bioprosthesis. One hundred fifty-two patients with aortic valve disease were randomly assigned to receive either the MM (n = 76) or an EP prosthesis. There were 89 men (59%), and the mean age was 76 years. Echocardiograms from preoperative, postoperative, predismissal, and 1-year time points were analyzed. Baseline characteristics and preoperative echocardiograms were similar between the two groups. The median implant size was 23 mm for both. There were no early deaths, and 10 patients (7%) died after dismissal. One hundred seven of 137 patients (78%) had a 1-year echocardiogram, and none required aortic valve reoperation. The mean aortic valve gradient at dismissal was 19.4 mm Hg (MM) versus13.5 mm Hg (EP; p regression of LV mass index (MM, -32.4 g/m(2) versus EP, -27.0 g/m(2); p = 0.40). Greater preoperative LV mass index was the sole independent predictor of greater LV mass regression after surgery (p regression of LV mass during the first year after aortic valve replacement.

  12. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Melle, van Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie P. J.; Jongbloed, Monique R. M.; Post, Martijn C.; Sieswerda, Gertjan T.; in 't Veld, Anna Huis; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    Objectives To report the prevalence of aortic valve prosthesis patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis

  13. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; van Melle, Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C.; Sieswerda, Gertjan T.; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in

  14. Deficient signaling via Alk2 (Acvr1 leads to bicuspid aortic valve development.

    Directory of Open Access Journals (Sweden)

    Penny S Thomas

    Full Text Available Bicuspid aortic valve (BAV is the most common congenital cardiac anomaly in humans. Despite recent advances, the molecular basis of BAV development is poorly understood. Previously it has been shown that mutations in the Notch1 gene lead to BAV and valve calcification both in human and mice, and mice deficient in Gata5 or its downstream target Nos3 have been shown to display BAVs. Here we show that tissue-specific deletion of the gene encoding Activin Receptor Type I (Alk2 or Acvr1 in the cushion mesenchyme results in formation of aortic valve defects including BAV. These defects are largely due to a failure of normal development of the embryonic aortic valve leaflet precursor cushions in the outflow tract resulting in either a fused right- and non-coronary leaflet, or the presence of only a very small, rudimentary non-coronary leaflet. The surviving adult mutant mice display aortic stenosis with high frequency and occasional aortic valve insufficiency. The thickened aortic valve leaflets in such animals do not show changes in Bmp signaling activity, while Map kinase pathways are activated. Although dysfunction correlated with some pro-osteogenic differences in gene expression, neither calcification nor inflammation were detected in aortic valves of Alk2 mutants with stenosis. We conclude that signaling via Alk2 is required for appropriate aortic valve development in utero, and that defects in this process lead to indirect secondary complications later in life.

  15. An up-to-date overview of the most recent transcatheter implantable aortic valve prostheses

    NARCIS (Netherlands)

    Wiegerinck, Esther M. A.; van Kesteren, Floortje; van Mourik, Martijn S.; Vis, Marije M.; Baan, Jan

    2016-01-01

    Over the past decade transcatheter aortic valve implantation (TAVI) has evolved towards the routine therapy for high-risk patients with severe aortic valve stenosis. Technical refinements in TAVI are rapidly evolving with a simultaneous expansion of the number of available devices. This review will

  16. [Long-term outcome of aortic valve sparing procedures in connective tissue disorders].

    Science.gov (United States)

    Tanaka, Hiroshi; Ogino, H; Matsuda, H; Minatoya, K; Sasaki, N

    2009-10-01

    The aim of this study is to determine the long-term outcome of aortic valve sparing procedures for patients having connective tissue disorder. Between 1993 and 2008, the aortic valve sparing surgery was performed in 94 patients having aortic root dilatation. Eighty patients of them (37.2 +/- 13.4 years, 50 male) had cystic medial necrosis in the aortic wall, which was confirmed the pathological examination. We reviewed these patients. Sixty percent (48/80) had Marfan syndrome, 5% (4/80) had Loeyz-Dietz syndrome, 2% (2/80) had bicuspid aortic valve, and 11% (9/80) had aortic dissection. Our reimplantation procedure has been refined as followed: with a tube graft in 41, a tube graft with creation of neo-sinuses in 11, and a Valsalva graft in 14. Fourteen patients underwent the remodeling procedure. The follow-up rate was 100% with the duration of 3.7+/- 3.4 years. There were no operative death but six late deaths. Seventeen (21.3%) patients required aortic valve replacement, for recurrent aortic insufficiency in 13 and infection in 4. Freedom from reoperation was 80%, 43%, and freedom from moderate or severe aortic insufficiency was 80%, 54%, at 5 and 10 years, respectively. Pathological findings of the aortic valve obtained in the reoperations showed elongation and prolapse of the aortic valve due to myxomatous degeneration and fibrous thickening caused by aortic insufficiency. Even in connective tissue disorders, aortic valve sparing operation is associated with acceptable long-term durability, although cusp degeneration resulting in recurrent aortic insufficiency might be progressive.

  17. 6-month aortic valve implantation of an off-the-shelf tissue-engineered valve in sheep.

    Science.gov (United States)

    Syedain, Zeeshan; Reimer, Jay; Schmidt, Jillian; Lahti, Matthew; Berry, James; Bianco, Richard; Tranquillo, Robert T

    2015-12-01

    Diseased aortic valves often require replacement, with over 30% of the current aortic valve surgeries performed in patients who will outlive a bioprosthetic valve. While many promising tissue-engineered valves have been created in the lab using the cell-seeded polymeric scaffold paradigm, none have been successfully tested long-term in the aortic position of a pre-clinical model. The high pressure gradients and dynamic flow across the aortic valve leaflets require engineering a tissue that has the strength and compliance to withstand high mechanical demand without compromising normal hemodynamics. A long-term preclinical evaluation of an off-the-shelf tissue-engineered aortic valve in the sheep model is presented here. The valves were made from a tube of decellularized cell-produced matrix mounted on a frame. The engineered matrix is primarily composed of collagen, with strength and organization comparable to native valve leaflets. In vitro testing showed excellent hemodynamic performance with low regurgitation, low systolic pressure gradient, and large orifice area. The implanted valves showed large-scale leaflet motion and maintained effective orifice area throughout the duration of the 6-month implant, with no calcification. After 24 weeks implantation (over 17 million cycles), the valves showed no change in tensile mechanical properties. In addition, histology and DNA quantitation showed repopulation of the engineered matrix with interstitial-like cells and endothelialization. New extracellular matrix deposition, including elastin, further demonstrates positive tissue remodeling in addition to recellularization and valve function. Long-term implantation in the sheep model resulted in functionality, matrix remodeling, and recellularization, unprecedented results for a tissue-engineered aortic valve. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Periostin Expression is Altered in Aortic Valves in Smad6 Mutant Mice

    Science.gov (United States)

    Sugi, Yukiko; Kern, Michael J; Markwald, Roger R; Burnside, Jessica L

    2013-01-01

    Smad6 is known to predominantly inhibit BMP signaling by negatively regulating the BMP signaling process. Therefore, Smad6 mutation potentially provides an important genetic model for investigating the role of BMP signaling in vivo. Periostin is a 90-kDA secreted extracellular matrix (ECM) protein and implicated in cardiac valve progenitor cell differentiation, maturation and adult aortic valve calcification in mice. We have previously reported periostin expression patterns during AV valve development in mice. Because periostin can play critical roles in aortic valve interstitial cell differentiation and can be correlated with adult valve disease pathogenesis, in the present study we specifically focused on periostin expression during outflow tract (OT) development and its expression within the adult mouse valves. We previously reported that periostin expression in valve progenitor cells was altered by exogenously adding BMP-2 in culture. In this study, we investigated whether expression of periostin and other valvulogenic ECM proteins was altered in Smad6-mutant newborn mice in vivo. Periostin protein was localized within OT during embryonic development in mice. At embryonic day (ED) 13.5, robust periostin expression was detected within the developing pulmonary trunk and developing pulmonary and aortic valves. Periostin expression remained intense in pulmonary and aortic valves up to the adult stage. Our immunohistochemical and immunointensity analyses revealed that periostin expression was significantly reduced in the aortic valves in Smad6−/− neonatal hearts. Versican expression was also significantly reduced in Smad6−/− aortic valves, whereas, hyaluronan deposition was not significantly altered in the Smad6−/− neonatal valves. Expression of periostin and versican was less prominently affected in AV valves compared to the aortic valves, suggesting that a cell lineage/origin-dependent response to regulatory molecules may play a critical role in valve

  19. Transcatheter implantation of a new prototype of self-expanding aortic valve prosthesis: first experience

    Directory of Open Access Journals (Sweden)

    Е. И. Кретов

    2016-12-01

    Full Text Available Calcific aortic stenosis is an aortic valve disease of atherosclerotic origin occurring in 2-4 % of persons older than 65 years, for whom open surgery is contraindicated. Models of self-expanding aortic valves available today have a number of significant drawbacks. The authors have developed a prototype of a new aortic valve and present its first successful implantation in the experiment.Received 17 October 2016. Accepted 22 November 2016.Funding: The study had no sponsorship.Conflict of interest: The authors declare no conflict of interest.

  20. Concomitant mitral valve surgery with aortic valve replacement: a 21-year experience with a single mechanical prosthesis

    Directory of Open Access Journals (Sweden)

    Sidhu Pushpinder

    2007-05-01

    Full Text Available Abstract Background Long-term survival for combined aortic and mitral valve replacement appears to be determined by the mitral valve prosthesis from our previous studies. This 21-year retrospective study assess long-term outcome and durability of aortic valve replacement (AVR with either concomitant mitral valve replacement (MVR or mitral valve repair (MVrep. We consider only a single mechanical prosthesis. Methods Three hundred and sixteen patients underwent double valve replacement (DVR (n = 273 or AVR+MVrep (n = 43, in the period 1977 to 1997. Follow up of 100% was achieved via telephone questionnaire and review of patients' medical records. Actuarial analysis of long-term survival was determined by Kaplan-Meier method. The Cox regression model was used to evaluate potential predictors of mortality. Results There were seventeen cases (5.4% of early mortality and ninety-six cases of late mortality. Fifteen-year survival was similar in both groups at 44% and 57% for DVR and AVR+MVrep respectively. There were no significant differences in valve related deaths, anticoagulation related complications, or prosthetic valve endocarditis between the groups. There were 6 cases of periprosthetic leak in the DVR group. Sex, pre-operative mitral and aortic valve pathology or previous cardiac surgery did not significantly affect outcome. Conclusion The mitral valve appears to be the determinant of survival following double valve surgery and survival is not significantly influenced by mitral valve repair.

  1. Epicardial Adipose Tissue Thickness Independently Predicts Severe Aortic Valve Stenosis.

    Science.gov (United States)

    Mahabadi, Amir A; Kahlert, Heike A; Dykun, Iryna; Balcer, Bastian; Kahlert, Philipp; Rassaf, Tienush

    2017-05-01

    Epicardial fat tissue (EAT) is associated with coronary as well as aortic valve calcification. The study aim was to determine whether EAT thickness is different in patients with and without aortic valve stenosis (AVS). A cohort of 200 consecutive patients with severe AVS and 200 matched patients without AVS were included retrospectively in the study. EAT thickness was quantified, using transthoracic echocardiography, as the space between the epicardial wall of the myocardium and the visceral layer of the pericardium. Unadjusted and risk factor-adjusted logistic regression analysis was used to determine the association of EAT thickness with the presence of AVS. Overall, 400 patients (182 males, 218 females; mean age 79.6 ± 6.5 years) were included in the study. EAT thickness was significantly higher in patients with severe AVS (7.4 ± 0.3 mm versus 5.8 ± 0.2 mm; p EAT by one standard deviation was associated with a two-fold increased occurrence of AVS (OR [95%CI]: 2.10 [1.65-2.68]; p EAT and AVS was independent of BMI (1.78 [1.15-2.75], 2.62 [1.71- 4.02], and 2.22 [1.36- 3.62], for BMI 30kg/ m2, respectively). EAT, in addition to traditional cardiovascular risk factors, significantly improved the area under the receiver operating characteristic curve (from 0.70 to 0.76; p = 0.003). EAT thickness is significantly associated with severe AVS, independent of traditional risk factors. While further studies are needed to confirm these results, the present findings support the hypothesis that EAT may influence sclerosis of the aortic valve.

  2. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients

    DEFF Research Database (Denmark)

    Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J

    2017-01-01

    BACKGROUND: Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. METHODS......: We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause...... or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. RESULTS: A total of 1746 patients underwent randomization at 87 centers...

  3. Aortic valve endocarditis complicated by ST-elevation myocardial infarction.

    Science.gov (United States)

    Jenny, Benjamin E; Almanaseer, Yassar

    2014-12-01

    Infective endocarditis complicated by abscess formation and coronary artery compression is a rare clinical event with a high mortality rate, and diagnosis requires a heightened degree of suspicion. We present the clinical, angiographic, and echocardiographic features of a 73-year-old woman who presented with dyspnea and was found to have right coronary artery compression that was secondary to abscess formation resulting from diffuse infectious endocarditis. We discuss the patient's case and briefly review the relevant medical literature. To our knowledge, this is the first reported case of abscess formation involving a native aortic valve and the right coronary artery.

  4. Aortic valve replacement in a patient with severe nickel allergy.

    Science.gov (United States)

    Lusini, Mario; Barbato, Raffaele; Spadaccio, Cristiano; Chello, Massimo

    2011-11-01

    Nickel allergy can raise clinical problems in patients undergoing cardiac surgery who require sternal closure with stainless steel wire. We describe the case of a 51-year-old woman with severe nickel allergy who underwent aortic valve replacement with a nickel-free ON-X prosthesis and sternal closure by Fiberwire # 2 suture without complications. Considering its biocompatibility and its mechanical characteristics including optimal strength and knot resistance, this suture might be a viable alternative in patients in which the use of stainless steel wire is contraindicated. © 2011 Wiley Periodicals, Inc.

  5. Calcific aortic valve damage as a risk factor for cardiovascular events

    International Nuclear Information System (INIS)

    Wasilewski, Jarosław; Mirota, Kryspin; Wilczek, Krzysztof; Głowacki, Jan; Poloński, Lech

    2012-01-01

    Aortic valve calcification (AVC) is a common disease of the elderly. It is a progressive disease ranging from mild valve thickening to severe calcification with aortic valve stenosis. Risk factors for AVC are similar to those for atherosclerosis: age, gender, hypercholesterolemia, diabetes, hypertension, smoking and renal failure. AVC shares many similarities to atherosclerosis, including inflammatory cells and calcium deposits, and correlates with coronary plaque burden. Presence of AVC is associated with increased risk of adverse cardiovascular events. The objective for this review is to discuss the clinical features, natural history and prognostic significance of aortic valve calcifications, including mechanical and hemodynamic factors of flow distribution

  6. Hemolytic Anemia after Aortic Valve Replacement: a Case Report.

    Science.gov (United States)

    Sabzi, Feridoun; Khosravi, Donya

    2015-01-01

    Hemolytic anemia is exceedingly rare and an underestimated complication after aortic valve replacement (AVR).The mechanism responsible for hemolysis most commonly involves a regurgitated flow or jet that related to paravalvar leak or turbulence of subvalvar stenosis. It appears to be independent of its severity as assessed by echocardiography. We present a case of a 24-year-old man with a history of AVR in 10 year ago that developed severe hemolytic anemia due to a mild subvalvar stenosis caused by pannus formation and mild hypertrophic septum. After exclusion of other causes of hemolytic anemia and the lack of clinical and laboratory improvement, the patient underwent redo valve surgery with pannus and subvalvar hypertrophic septum resection. Anemia and heart failure symptoms gradually resolved after surgery.

  7. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties.

    Science.gov (United States)

    Kalejs, Martins; Stradins, Peteris; Lacis, Romans; Ozolanta, Iveta; Pavars, Janis; Kasyanov, Vladimir

    2009-05-01

    The major problem with heart valve bioprostheses made from chemically treated porcine aortic valves is their limited longevity caused by gradual deterioration, which has a causal link with valve tissue mechanical properties. To our best knowledge, there are no published studies on the mechanical properties of modern, commercially available bioprostheses comparing them to native human valves. The objective of this study is to determine the mechanical properties of St Jude Epic bioprostheses and to compare them with native human and porcine aortic valves. Leaflets from eight porcine aortic valves and six Epic bioprostheses were analyzed using uni-axial tensile tests in radial and circumferential directions. Mechanical properties of human valves have been previously published by our group. Results are represented as mean values+/-S.D. Circumferential direction. Modulus of elasticity of Epic bioprostheses in circumferential direction at the level of stress 1.0 MPa is 101.99+/-58.24 MPa, 42.3+/-4.96 MPa for native porcine and 15.34+/-3.84 MPa for human aortic valves. Ultimate stress is highest for Epic bioprostheses 5.77+/-1.94 MPa, human valves have ultimate stress of 1.74+/-0.29 MPa and porcine 1.58+/-0.26 MPa. Ultimate strain in circumferential direction is highest for human valves 18.35+/-7.61% followed by 7.26+/-0.69% for porcine valves and 5.95+/-1.54% for Epic bioprostheses. Radial direction. Modulus of elasticity in radial direction is 9.18+/-1.81 MPa for Epic bioprostheses, 5.33+/-0.61 MPa for native porcine, and 1.98+/-0.15 MPa for human aortic valve leaflets. In the radial direction ultimate stress is highest for Epic bioprostheses 0.7+/-0.21 MPa followed by native porcine valves 0.55+/-0.11 MPa and 0.32+/-0.04 MPa for human valves. For human valves ultimate strain is 23.92+/-4.87%, for native porcine valves 8.57+/-0.8% and 7.92+/-1.74% for Epic bioprostheses. Epic bioprostheses have non-linear stress-strain behavior similar to native valve tissue, but they

  8. New Fibrillin Gene Mutation - Possible Cause of Ascending Aortic Dilation in Patients with Aortic Valve Disease: Preliminary Results

    Czech Academy of Sciences Publication Activity Database

    Dudra, J.; Lindner, J.; Vaněk, I.; Šímová, Jana; Mazura, Ivan; Miler, I.; Čiháková, J.; Čapek, P.; Belák, J.

    2009-01-01

    Roč. 18, č. 2 (2009), s. 99-102 ISSN 1061-1711 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : aortic valve disease * ascending aortic dilatation * fibrilin gene mutation Subject RIV: EB - Gene tics ; Molecular Biology

  9. Outcomes in patients with contained ruptures of the aortic annulus after transcatheter aortic valve implantation with balloon-expandable devices

    DEFF Research Database (Denmark)

    Breitbart, Philipp; Minners, Jan; Pache, Gregor

    2017-01-01

    ) at three centers in Germany and Denmark. CR were identified in 12 patients (1.2%, 80.7+5.0 years, STS-Score 4.1+1.4%). All 12 patients had received a balloon-expandable valve. In 3 patients periprocedural transesophageal echocardiography revealed findings suggestive of aortic dissection, an aortic...

  10. Long-term results of aortic valve-sparing operations in patients with Marfan syndrome.

    Science.gov (United States)

    David, Tirone E; Armstrong, Sue; Maganti, Manjula; Colman, Jack; Bradley, Timothy J

    2009-10-01

    The appropriateness of aortic valve-sparing operations in patients with Marfan syndrome has been questioned. This study examines the long-term results of these operations in patients with Marfan syndrome. From 1988 to 2006, 103 consecutive patients with Marfan syndrome (mean age, 37 +/- 12 years) and aortic root aneurysm had aortic valve-sparing operations. Emergency surgery was performed in 11 patients: 8 for acute type A aortic dissection and 3 for unexplained persistent chest pain. Fourteen patients also had mitral valve surgery. The technique of aortic valve reimplantation was used in 77 patients, and aortic root remodeling was used in 26 patients. Patients were followed prospectively and underwent annual echocardiographic studies. The mean follow-up was 7.3 +/- 4.2 years and 100% complete. There was 1 operative death and 5 late deaths. Four of the 6 deaths were due to complications of aortic dissections. The patients' survival at 15 years was 87.2% compared with 95.6% for the general population of Ontario matched for age and sex. Seven patients had important aortic insufficiency: 4 mild to moderate, 2 moderate, and 1 moderate to severe. Freedom from greater than mild aortic insufficiency at 15 years was 79.2%. Three patients, all after aortic root remodeling, had aortic valve replacement, 2 for aortic insufficiency and 1 for endocarditis. At the most recent follow-up, 97 patients were alive: 86 were in functional class I, and 11 were in functional class II. Aortic valve-sparing operations provided excellent clinical outcomes in this series of patients with Marfan syndrome. Postoperatively, complications of aortic dissections were the leading cause of death.

  11. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement

    Science.gov (United States)

    Reynolds, Matthew R.; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A.; Magnuson, Elizabeth A.; Galper, Benjamin Z.; Meduri, Christopher U.; Arnold, Suzanne V.; Baron, Suzanne J.; Reardon, Michael J.; Adams, David H.; Popma, Jeffrey J.; Cohen, David J.

    2016-01-01

    Background Prior studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk pivotal trial. Empirical data regarding survival and quality of life (QOL) over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month QOL. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALYs; 0.41 life-years [LYs]) with 3% discounting. Lifetime incremental cost-effectiveness ratios (ICERs) were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ~$1,650 would lead to an ICER prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. PMID:26764063

  12. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Cost-effectiveness of transcatheter aortic valve replacement compared with surgical aortic valve replacement in high-risk patients with severe aortic stenosis: results of the PARTNER (Placement of Aortic Transcatheter Valves) trial (Cohort A).

    Science.gov (United States)

    Reynolds, Matthew R; Magnuson, Elizabeth A; Lei, Yang; Wang, Kaijun; Vilain, Katherine; Li, Haiyan; Walczak, Joshua; Pinto, Duane S; Thourani, Vinod H; Svensson, Lars G; Mack, Michael J; Miller, D Craig; Satler, Lowell E; Bavaria, Joseph; Smith, Craig R; Leon, Martin B; Cohen, David J

    2012-12-25

    The aim of this study was to evaluate the cost-effectiveness of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (AVR) for patients with severe aortic stenosis and high surgical risk. TAVR is an alternative to AVR for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis based on cost, quality of life, and survival data collected in the PARTNER A (Placement of Aortic Transcatheter Valves) trial in which patients with severe aortic stenosis and high surgical risk were randomized to TAVR or AVR. Cumulative 12-month costs (assessed from a U.S. societal perspective) and quality-adjusted life-years (QALYs) were compared separately for the transfemoral (TF) and transapical (TA) cohorts. Although 12-month costs and QALYs were similar for TAVR and AVR in the overall population, there were important differences when results were stratified by access site. In the TF cohort, total 12-month costs were slightly lower with TAVR and QALYs were slightly higher such that TF-TAVR was economically dominant compared with AVR in the base case and economically attractive (incremental cost-effectiveness ratio economically dominated by AVR in the base case and economically attractive in only 7.1% of replicates. In the PARTNER trial, TAVR was an economically attractive strategy compared with AVR for patients suitable for TF access. Future studies are necessary to determine whether improved experience and outcomes with TA-TAVR can improve its cost-effectiveness relative to AVR. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. The power of disruptive technological innovation: Transcatheter aortic valve implantation.

    Science.gov (United States)

    Berlin, David B; Davidson, Michael J; Schoen, Frederick J

    2015-11-01

    We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity. © 2014 Wiley Periodicals, Inc.

  15. Design of Bioprosthetic Aortic Valves using biaxial test data.

    Science.gov (United States)

    Dabiri, Y; Paulson, K; Tyberg, J; Ronsky, J; Ali, I; Di Martino, E; Narine, K

    2015-01-01

    Bioprosthetic Aortic Valves (BAVs) do not have the serious limitations of mechanical aortic valves in terms of thrombosis. However, the lifetime of BAVs is too short, often requiring repeated surgeries. The lifetime of BAVs might be improved by using computer simulations of the structural behavior of the leaflets. The goal of this study was to develop a numerical model applicable to the optimization of durability of BAVs. The constitutive equations were derived using biaxial tensile tests. Using a Fung model, stress and strain data were computed from biaxial test data. SolidWorks was used to develop the geometry of the leaflets, and ABAQUS finite element software package was used for finite element calculations. Results showed the model is consistent with experimental observations. Reaction forces computed by the model corresponded with experimental measurements when the biaxial test was simulated. As well, the location of maximum stresses corresponded to the locations of frequent tearing of BAV leaflets. Results suggest that BAV design can be optimized with respect to durability.

  16. Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment.

    Science.gov (United States)

    Bissell, Malenka M; Loudon, Margaret; Hess, Aaron T; Stoll, Victoria; Orchard, Elizabeth; Neubauer, Stefan; Myerson, Saul G

    2018-02-08

    Abnormal aortic flow patterns in bicuspid aortic valve disease (BAV) may be partly responsible for the associated aortic dilation. Aortic valve replacement (AVR) may normalize flow patterns and potentially slow the concomitant aortic dilation. We therefore sought to examine differences in flow patterns post AVR. Ninety participants underwent 4D flow cardiovascular magnetic resonance: 30 BAV patients with prior AVR (11 mechanical, 10 bioprosthetic, 9 Ross procedure), 30 BAV patients with a native aortic valve and 30 healthy subjects. The majority of subjects with mechanical AVR or Ross showed normal flow pattern (73% and 67% respectively) with near normal rotational flow values (7.2 ± 3.9 and 10.6 ± 10.5 mm 2 /ms respectively vs 3.8 ± 3.1 mm 2 /s for healthy subjects; both p > 0.05); and reduced in-plane wall shear stress (0.19 ± 0.13 N/m 2 for mechanical AVR vs. 0.40 ± 0.28 N/m 2 for native BAV, p flow patterns (mainly marked right-handed helical flow), with comparable rotational flow values to native BAV (20.7 ± 8.8 mm 2 /ms and 26.6 ± 16.6 mm 2 /ms respectively, p > 0.05), and a similar pattern for wall shear stress. Data before and after AVR (n = 16) supported these findings: mechanical AVR showed a significant reduction in rotational flow (30.4 ± 16.3 → 7.3 ± 4.1 mm 2 /ms; p flow patterns in BAV disease tend to normalize after mechanical AVR or Ross procedure, in contrast to the remnant abnormal flow pattern after bioprosthetic AVR. This may in part explain different aortic growth rates post AVR in BAV observed in the literature, but requires confirmation in a prospective study.

  17. Initial Surgical Experience with Aortic Valve Repair: Clinical and Echocardiographic Results

    Science.gov (United States)

    da Costa, Francisco Diniz Affonso; Colatusso, Daniele de Fátima Fornazari; da Costa, Ana Claudia Brenner Affonso; Balbi Filho, Eduardo Mendel; Cavicchioli, Vinicius Nesi; Lopes, Sergio Augusto Veiga; Ferreira, Andrea Dumsch de Aragon; Collatusso, Claudinei

    2016-01-01

    Introduction Due to late complications associated with the use of conventional prosthetic heart valves, several centers have advocated aortic valve repair and/or valve sparing aortic root replacement for patients with aortic valve insufficiency, in order to enhance late survival and minimize adverse postoperative events. Methods From March/2012 thru March 2015, 37 patients consecutively underwent conservative operations of the aortic valve and/or aortic root. Mean age was 48±16 years and 81% were males. The aortic valve was bicuspid in 54% and tricuspid in the remaining. All were operated with the aid of intraoperative transesophageal echocardiography. Surgical techniques consisted of replacing the aortic root with a Dacron graft whenever it was dilated or aneurysmatic, using either the remodeling or the reimplantation technique, besides correcting leaflet prolapse when present. Patients were sequentially evaluated with clinical and echocardiographic studies and mean follow-up time was 16±5 months. Results Thirty-day mortality was 2.7%. In addition there were two late deaths, with late survival being 85% (CI 95% - 68%-95%) at two years. Two patients were reoperated due to primary structural valve failure. Freedom from reoperation or from primary structural valve failure was 90% (CI 95% - 66%-97%) and 91% (CI 95% - 69%-97%) at 2 years, respectively. During clinical follow-up up to 3 years, there were no cases of thromboembolism, hemorrhage or endocarditis. Conclusions Although this represents an initial series, these data demonstrates that aortic valve repair and/or valve sparing aortic root surgery can be performed with satisfactory immediate and short-term results. PMID:27556321

  18. Computed Tomography Aortic Valve Calcium Scoring in Patients With Aortic Stenosis.

    Science.gov (United States)

    Pawade, Tania; Clavel, Marie-Annick; Tribouilloy, Christophe; Dreyfus, Julien; Mathieu, Tiffany; Tastet, Lionel; Renard, Cedric; Gun, Mesut; Jenkins, William Steven Arthur; Macron, Laurent; Sechrist, Jacob W; Lacomis, Joan M; Nguyen, Virginia; Galian Gay, Laura; Cuéllar Calabria, Hug; Ntalas, Ioannis; Cartlidge, Timothy Robert Graham; Prendergast, Bernard; Rajani, Ronak; Evangelista, Arturo; Cavalcante, João L; Newby, David E; Pibarot, Philippe; Messika Zeitoun, David; Dweck, Marc R

    2018-03-01

    Computed tomography aortic valve calcium scoring (CT-AVC) holds promise for the assessment of patients with aortic stenosis (AS). We sought to establish the clinical utility of CT-AVC in an international multicenter cohort of patients. Patients with AS who underwent ECG-gated CT-AVC within 3 months of echocardiography were entered into an international, multicenter, observational registry. Optimal CT-AVC thresholds for diagnosing severe AS were determined in patients with concordant echocardiographic assessments, before being used to arbitrate disease severity in those with discordant measurements. In patients with long-term follow-up, we assessed whether CT-AVC thresholds predicted aortic valve replacement and death. In 918 patients from 8 centers (age, 77±10 years; 60% men; peak velocity, 3.88±0.90 m/s), 708 (77%) patients had concordant echocardiographic assessments, in whom CT-AVC provided excellent discrimination for severe AS (C statistic: women 0.92, men 0.89). Our optimal sex-specific CT-AVC thresholds (women 1377 Agatston unit and men 2062 Agatston unit) were nearly identical to those previously reported (women 1274 Agatston unit and men 2065 Agatston unit). Clinical outcomes were available in 215 patients (follow-up 1029 [126-2251] days). Sex-specific CT-AVC thresholds independently predicted aortic valve replacement and death (hazard ratio, 3.90 [95% confidence interval, 2.19-6.78]; P <0.001) after adjustment for age, sex, peak velocity, and aortic valve area. Among 210 (23%) patients with discordant echocardiographic assessments, there was considerable heterogeneity in CT-AVC scores, which again were an independent predictor of clinical outcomes (hazard ratio, 3.67 [95% confidence interval, 1.39-9.73]; P =0.010). Sex-specific CT-AVC thresholds accurately identify severe AS and provide powerful prognostic information. These findings support their integration into routine clinical practice. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT

  19. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves.

    Science.gov (United States)

    Egron, Sandrine; Fujita, Buntaro; Gullón, Lucía; Désirée, Pott; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-09-05

    The goal is to inform in depth on transcatheter aortic valve replacement (TAVR) prosthesis mechanical behavior, depending on frame type, design, and size, and how it crucially impacts the oversizing issue in clinical use, and ultimately the procedure outcome. Transcatheter aortic valve replacement is an established therapy for high-risk patients suffering from aortic stenosis, and the indication for TAVR is progressively expanding to intermediate-risk patients. Choosing the optimal oversizing degree is crucial to safely anchor the TAVR valve-which involves limiting the risks for embolism, aortic regurgitation, conductance disturbance, or annulus rupture-and to increase the valve prosthesis performance. The radial force (RF) profiles of five TAVR prostheses were measured in vitro: the CoreValve 23 and 26 (Medtronic, MN), the Acurate neo S (Symetis, Switzerland), and the SAPIEN XT 23 and 26 (Edwards Lifesciences, CA). Measurements were run with the RX Machine equipment (Machine Solutions Inc., AZ), which is used in ISO standard tests for intravascular stents. Test protocols were adapted for TAVR prostheses. With the prostheses RF profiles' results, mechanical behavior differences could be described and discussed in terms of oversizing strategy and clinical impact for all five valves. Besides, crossing the prostheses' RF profiles with their recommended size windows made the assessment of borderline size cases possible and helped analyze the risks when accurate measurement of patient aortic annulus proves difficult. The prostheses' RF profiles bring new support in clinical decision-making for valve type and size in patients.

  20. Sutureless implantation of the perceval s aortic valve prosthesis through right anterior minithoracotomy.

    Science.gov (United States)

    Gilmanov, Daniyar; Miceli, Antonio; Bevilacqua, Stefano; Farneti, Pierandrea; Solinas, Marco; Ferrarini, Matteo; Glauber, Mattia

    2013-12-01

    Many new, less invasive strategies are proposed for aortic valve operation in elderly patients. Rapid deployment sutureless aortic valve prosthesis has been recently introduced. We analyzed our experience with a sutureless valve implanted through a minimally invasive approach. A retrospective observational study with prospectively registered data was conducted on 137 patients undergoing aortic valve replacement through a right anterior minithoracotomy. Between April 2011 and January 2013, 137 consecutive patients underwent aortic valve replacement with a recently introduced, rapid deployment, sutureless pericardial valve in minithoracotomy access (47 men; mean age, 76.6 ± 7.1 years). There were 35 obese patients with a body mass index of more than 30 kg/m(2). Mean logistic EuroSCORE I was 10.0; 74 (54%) patients were in New York Heart Association functional class III and IV. In all, 19 (13.9%), 45 (32.8%), and 73 (53.3%) patients received 21-, 23-, and 25-mm valve prostheses, respectively. The mean aortic cross-clamp and cardiopulmonary bypass times were 59.3 ± 19 min and 92.3 ± 27 min, respectively. No operative mortality occurred. Median stay in the intensive care unit was 1 day, with assisted ventilation necessary for a median of 6 hours. Three cases of postoperative ischemic stroke were observed (1 patient with a previous history of an ischemic cerebral event). Median hospital length of stay was 6 days. A sutureless valve for minimally invasive aortic valve replacement is a feasible, effective, and safe tool. Ultimately amplifying indications for less invasive aortic valve replacement in a high surgical risk subset of patients, it can become a valid alternative for transcatheter aortic valve implantation. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Early impact of aortic wrapping on patients undergoing aortic valve replacement with mild to moderate ascending aorta dilatation

    Directory of Open Access Journals (Sweden)

    Sosnowski Andrzej

    2010-08-01

    Full Text Available Abstract Background The management of mild to moderate dilatation of the ascending aorta of less than 5 cm is controversial, particularly when concomitant surgical correction of aortic valve is required. We investigate the impact of a simple method of aorta reduction using Dacron graft wrapping during aortic valve replacement on the rest of the aorta. Methods We studied 14 patients who had ascending aorta dilatation of 4-5 cm before undergoing aortic wrapping during their aortic valve replacement and compared with their post-operative imaging within a month. Results The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within 4 weeks after surgery from 44.7 ± 2.6 to 33.6 ± 3.9 mm (p Conclusions Reduction of ascending aortic dilatation by wrapping with a Dacron graft in this preliminary study is associated with favourable early reversed aortic remodelling. This supports the hypothesis that correction of mild-moderate dilatation of the ascending aorta with Dacron wrapping at the time of aortic valve surgery may prevent the progression of the dilatation, although the long-term study on a larger population is needed to confirm its benefits.

  2. [Valve-sparing aortic root replacement for young female patients with Marfan syndrome].

    Science.gov (United States)

    Nawata, Kan; Morota, T

    2009-10-01

    Annuloaortic ectasia is frequently related with Marfan syndrome, and Bentall procedure or aortic root replacement with valved conduit has been the conventional standard operation for this disease. Recently, some institutes have adopted valve-sparing aortic root replacement (VSARR) instead of Bentall procedure. Young female patients with Marfan syndrome who wishes for childbearing seem to be a group of good candidates of this type of operation, because it let them free from morbidities after artificial valve implantation. Valve-sparing operation should be taken into consideration when the size of Valsalva sinus reaches 45 mm for patients with Marfan syndrome and when it reaches 40 mm for patients with past histories or family histories of aortic dissection or aortic rupture. Since pregnancy is one of the most serious risk factors for aortic events, Valsalva sinus of 40 mm or larger could be the new standard for surgical indication if VSARR is applicable.

  3. Successful implantation of a second-generation aortic valve in severe aortic regurgitation secondary to a traumatic cusp lesion

    Energy Technology Data Exchange (ETDEWEB)

    Mangieri, Antonio [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); EMO-GVM Centro Cuore Columbus, Milan (Italy); Aurelio, Andrea [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); Figini, Filippo [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); EMO-GVM Centro Cuore Columbus, Milan (Italy); Agricola, Eustachio; Rosa, Isabella; Stella, Stefano; Spagnolo, Pietro; Castiglioni, Alessandro [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); Colombo, Antonio [Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan (Italy); EMO-GVM Centro Cuore Columbus, Milan (Italy)

    2015-10-15

    A 67-year-old man with a dilated cardiomyopathy and severe aortic regurgitation (AR) secondary to a traumatic cusp lesion was referred to our institution because of progressive worsening of dyspnea. After formal discussion in the heart team, the patient was scheduled for TAVI (transcatheter aortic valve implantation). The pre procedural computed tomography scan revealed a minimum amount of calcium on the aortic valve and low position of coronary ostia. The TAVI procedure was performed with the implantation of a fully retrievable and repositionable aortic valve prosthesis (Direct Flow 29 mm, Direct Flow Medical, Santa Rosa, California) with an excellent result and no paravalvular leak. The TAVI devices designed for the treatment of calcific aortic stenosis have numerous limitations for the treatment of pure AR such as the risk of residual AR, the lack of repositionability and retrievability, and the need for valve- in-valve implantation. We believe that treatment of selected cases of pure AR with the Direct Flow valve is feasible and takes advantage of the retrievability of the prosthesis.

  4. A quarter of a century of experience with aortic valve-sparing operations.

    Science.gov (United States)

    David, Tirone E; Feindel, Christopher M; David, Carolyn M; Manlhiot, Cedric

    2014-09-01

    To examine the late outcomes of aortic valve-sparing operations to treat patients with aortic root aneurysm with and without aortic insufficiency (AI) in a cohort of patients followed up prospectively since 1988. A total of 371 consecutive patients had undergone aortic valve-sparing surgery (mean age, 47 ± 15 years; 78% men) from 1988 through 2010. In addition to the aortic root aneurysm, 47% had moderate or severe AI, 35.5% had Marfan syndrome, 12.1% had type A aortic dissection, 9.2% had bicuspid aortic valve, 8.4% had mitral insufficiency, 16.1% had aortic arch aneurysm, and 10.2% had coronary artery disease. Reimplantation of the aortic valve was used in 296 patients and remodeling of the aortic root in 75. Cusp repair by plication of the free margin along the nodule of Arantius was used in 36.6% of patients, and reinforcement of the free margin with a double layer of fine Gore-Tex suture in 24.2%. The patients were followed up prospectively with images of the aortic root for a median follow-up of 8.9 ± 5.2 years. A total of 4 operative and 39 late deaths occurred. Survival at 18 years was 76.8% ± 4.31%, lower than that for the general population matched for age and gender. Age, type A aortic dissection, impaired ventricular function, and preoperative AI were associated with increased mortality on multivariable analysis. Reoperations on the aortic valve were performed in 8 patients for recurrent AI and in 2 for infective endocarditis. Freedom from reoperation on the aortic valve at 18 years was 94.8% ± 2.0%. No predictors of the need for reoperation were found on multivariable analysis. Eighteen patients developed AI greater than mild. Freedom from AI greater than mild at 18 years was 78.0% ± 4.8%. No predictors of recurrent AI were identified on multivariable analysis. Aortic valve-sparing operations continue to provide excellent clinical outcomes, although a slow but progressive deterioration of aortic valve function seems to occur during the first 2

  5. High Risk Aortic Valve Replacement - The Challenges of Multiple Treatment Strategies with an Evolving Technology.

    Science.gov (United States)

    Booth, K; Beattie, R; McBride, M; Manoharan, G; Spence, M; Jones, J M

    2016-01-01

    Deciding on the optimal treatment strategy for high risk aortic valve replacement is challenging. Transcatheter Aortic Valve implantation (TAVI) has been available in our centre as an alternative treatment modality for patients since 2008. We present our early experience of TAVI and SAVR (surgical Aortic Valve Replacement) in high risk patients who required SAVR because TAVI could not be performed. The database for Surgical aortic valve and Transcatheter aortic valve replacement referrals was interrogated to identify relevant patients. Survival to hospital discharge was 95.5% in the forty five patients who had SAVR when TAVI was deemed technically unsuitable. One year survival was 86%. Defining who is appropriate for TAVI or high risk SAVR is challenging and multidisciplinary team discussion has never been more prudent in this field of evolving technology with ever decreasing risks of surgery. The introduction of TAVI at our institution has seen a rise in our surgical caseload by approximately by 25%. Overall, the option of aortic valve intervention is being offered to more patients in general which is a substantial benefit in the treatment of aortic valve disease.

  6. [A clinical experience of continuous warm blood cardioplegia in two cases of repeat aortic valve surgery].

    Science.gov (United States)

    Nagaoka, H; In-nami, R; Watanabe, M; Funakoshi, N; Hirooka, K; Fujiwara, A

    1992-11-01

    The continuous warm blood cardioplegia (CWBC) was used for myocardial protection during aortic cross clamping in two cases of repeat aortic valve operations with good results. Case 1: A 46-year-old man, who underwent an aortic valve replacement because of the rheumatic aortic regurgitation (AR) in 1978, have suffered from orthopnea due to para-prosthetic valvular regurgitation since 1983. He was revealed to have bi-ventricular hypertrophy with myocardial damage on ECG, EF 0.27 on UCG, PCWP 20 mmHg and severe AR on cardiac catheterization. Case 2: A 43-year-old man, who had an aortic valvuloplasty for the non-rheumatic incompetency in 1981, have had a recurrent regurgitation, resulting in left ventricular hypertrophy accompanied by chest pain. Both cases were reoperated upon, having aortic valve replacement with mechanical prosthetic valves through the re-median sternotomy, utilizing CWBC with good recovery. CWBC provides an ideal circumstances for myocardial oxygen utilization during aortic cross clamping and moreover a benefit that needs not the wide dissection of the heart in a redo case because it has no need of topical cooling and ventricular defibrillation following aortic declamping. In conclusion, CWBC is very useful in a repeat aortic valve surgery.

  7. Primary Mitral Valve Regurgitation Outcome in Patients With Severe Aortic Stenosis 1 Year After Transcatheter Aortic Valve Implantation: Echocardiographic Evaluation.

    Science.gov (United States)

    Florentino, Thiago Marinho; Bihan, David Le; Abizaid, Alexandre Antonio Cunha; Cedro, Alexandre Vianna; Corrêa, Amably Pessoa; Santos, Alexandre Roginski Mendes Dos; Souza, Alexandre Costa; Bignoto, Tiago Costa; Sousa, José Eduardo Moraes Rego; Sousa, Amanda Guerra de Moraes Rego

    2017-07-10

    Mitral valve regurgitation (MR), present in up to 74% of the patients with severe aortic stenosis (AS), can be a negative prognostic factor when moderate or severe. The outcome of MR after percutaneous transcatheter aortic valve implantation (TAVI) and predictors associated with that outcome have not been well established in the literature. To assess the outcome of primary MR in patients submitted to TAVI and to identify associated factors. Observational study of patients with symptomatic severe AS submitted to TAVI from January 2009 to April 2015 at two specialized centers. Echocardiographic outcome was assessed with data collected before and 1 year after TAVI. Of the 91 patients with MR submitted to TAVI and followed up for at least 12 months, 67 (73.6%) had minimum/mild MR before the procedure and 24 (26.4%) had moderate/severe MR. Of those with minimum/mild MR, 62 (92.5%) had no change in the MR grade (p valores de EuroSCORE II (p = 0,023) e STS morbidade (p = 0,027), quando comparados aos que continuaram na mesma classe. Observou-se mudança significativa no grau de IM após realização de TAVI. Este estudo sugere uma tendência de melhora da IM moderada ou grave após TAVI, o que se associou a escores de risco pré-operatórios menos elevados.

  8. A Review of Evolutionary and Cyclical Changes in the Surgical Approach to Aortic Valve Disease.

    Science.gov (United States)

    Piciche, Marco; Dato, Guglielmo Actis; Lorusso, Roberto; Musumeci, Francesco

    2018-01-31

    Aortic valve surgery is no exception to the general rule that history is a cycle in many fields. This manuscript aims to assist readers in transitioning from past to present and on into the future within the field of aortic valve surgery. The existing literature has been examined, including old and modern articles published on pubmed, old articles non visible on pubmed, old and recent books on the history of medicine, looking for similarities and repetitions in techniques and surgical approaches to the aortic valve in the past and the current times. Steps of evolution included a blind approach, plasty procedures under direct visualization of the valve without the aid of cardiopulmonary bypass, prosthetic valve replacements via sternotomies with cardiopulmonary bypass, minimally-invasive access routes, trans-catheter aortic valve implants (TAVI), suture-less prostheses, mini-thoracotomies incorporating suture-less prostheses, and finally, totally-endoscopic aortic valve replacements. After the advent of CPB and several decades of open-heart surgery with full sternotomies, the minimally-invasive approach has re-emerged. Supported by a commitment to smaller incisions and shorter bypass times, the concept is now being aggressively developed. The cycling of science, including the field of aortic valve surgery, means that ingenious theories and concepts that have fallen by the wayside can be brought back and explored again with current tools and enhanced knowledge. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Expanding indications for valve-sparing aortic root reconstruction: early and midterm results.

    Science.gov (United States)

    Valo, Johanna; Jokinen, Janne J; Kaarne, Markku; Ihlberg, Leo

    2013-02-01

    Valve-sparing aortic root reconstruction (VSRR) is an accepted method to treat patients with aortic root dilation. The role of the VSRR is less well defined for patients with bicuspid aortic valve, severe aortic valve insufficiency, congenital heart defects, and type A aortic dissection. We studied the clinical outcome of patients who underwent VSRR for expanded indications. Seventy-eight patients underwent VSRR between the 2005 and 2012. Seventy-two patients (92%) underwent reimplantation and 6 patients (8%) were operated on with the remodeling technique. The mean age was 51 ± 12 years (range 24 to 73). For 71 patients (91%), the operation was elective, and for 7 (9%; all with type A aortic dissection), on an emergency basis. Preoperatively, the degree of aortic insufficiency was graded as 2+ or greater for 27 patients (35%). Connective tissue disorder (Marfan or Loeys-Dietz), bicuspid aortic valve, or congenital heart disease was present in 15 (19%), 15 (19%), and 7 patients (9%), respectively. Concomitant aortic valve leaflet repair was performed for 39 patients (50%). The mean follow-up time was 2.4 ± 1.7 years (range, 0.1 to 7.0). Thirty-day mortality was zero. The rate of postoperative complications was low: stroke 3%, renal failure 3%, prosthesis infection 1%, and low cardiac output syndrome 1%. Survival was 100% at 1 year and 97% at 5 years. Freedom from recurrent aortic valve insufficiency (≥2+) during the follow-up was 94%. The midterm results of VSRR in terms of survival, freedom from recurrent aortic valve insufficiency, and the need for reoperation are excellent, even for high-risk patients. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Wall Stress and Geometry of the Thoracic Aorta in Patients With Aortic Valve Disease.

    Science.gov (United States)

    Doyle, Barry J; Norman, Paul E; Hoskins, Peter R; Newby, David E; Dweck, Marc R

    2018-04-01

    Aortic valve disease increases velocity and changes the way blood enters the aorta. Over time, the biomechanical environment can cause aortic remodelling. We hypothesized that aortic geometry and wall stress would be different in patients with aortic valve disease compared with controls. We examined 40 patients with aortic sclerosis (n = 10) or mild (n = 10), moderate (n = 10), and severe (n = 10) aortic stenosis, and also 10 control individuals. The thoracic aorta of each individual was reconstructed into a three-dimensional model from computed tomography. We measured geometric variables and used finite element analysis to compute aortic wall stress. Statistical analyses were performed to test our hypothesis. Aortic wall stress was significantly associated with tortuosity of the descending aorta (r = 0.35, p = 0.01), arch radius (r = 0.49, p < 0.01), ascending aortic diameter (r = 0.59, p < 0.01), and aortic centerline length (r = 0.39, p < 0.01). Wall stress was highest in patients with severe stenosis (p = 0.02), although elevations in wall stress were also noted in those with mild stenosis (p = 0.02), and aortic sclerosis (p = 0.02) compared with controls. Similar trends were observed when we corrected for difference in blood pressure. Total centerline tortuosity was higher in patients with severe aortic stenosis than in controls (p = 0.04), as was descending aorta tortuosity (p = 0.04). Aortic geometry is associated with aortic wall stress. Patients with aortic valve disease have higher aortic wall stress than controls, and those with severe aortic stenosis have more tortuous aortas. However, increases in geometric measures and wall stress are not stepwise with increasing disease severity. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Asymptomatic Interrupted Aortic Arch, Severe Tricuspid Regurgitation, and Bicuspid Aortic Valve in a 76-Year-Old Woman.

    Science.gov (United States)

    Tajdini, Masih; Sardari, Akram; Forouzannia, Seyed Khalil; Baradaran, Abdolvahab; Hosseini, Seyed Mohammad Reza; Kassaian, Seyed Ebrahim

    2016-10-01

    Interrupted aortic arch is a rare congenital abnormality with a high infancy mortality rate. The principal finding is loss of luminal continuity between the ascending and descending portions of the aorta. Because of the high mortality rate in infancy, interrupted aortic arch is very rare among adults. In this report, we describe the case of a 76-year-old woman with asymptomatic interrupted aortic arch, severe tricuspid regurgitation, and bicuspid aortic valve. To our knowledge, she is the oldest patient ever reported with this possibly unique combination of pathologic conditions. In addition to reporting her case, we review the relevant medical literature.

  12. [The cost of innovation in treating aortic stenosis: transcatheter aortic valve implantation].

    Science.gov (United States)

    Bartoli, Simona; Saia, Francesco; Marrozzini, Cinzia; Berti, Elena; Guastaroba, Paolo; Fortuna, Daniela; Ciuca, Cristina; Moretti, Carolina; Marzocchi, Antonio; De Palma, Rossana

    2012-01-01

    Transcatheter aortic valve implantation (TAVI) represents a promising therapeutic option for patients affected by severe aortic stenosis, but it is currently associated with high costs. Therefore, the assessment of its economic impact becomes urgent to support decision-makers' choices about its use, patient access to treatment and reimbursement mechanisms. A retrospective, observational, single-center (the teaching hospital located in Bologna, Italy) study was conducted. All patients with severe symptomatic aortic stenosis undergoing TAVI during the enrolment period (February 2008-August 2010) were included. The procedures were performed with both bioprostheses approved for clinical use and through different vascular access: CoreValve transfemoral (CV-TF), CoreValve transsubclavian (CV-TS), Edwards Sapien transapical (ES-TA), Edwards Sapien transfemoral (ES-TF). Costs of the whole index hospitalization have been calculated from the hospital perspective. Healthcare resource consumption was measured at patient level and assessed using unit costs (micro-costing approach). Overall, 87 consecutive patients (48 CV-TF, 12 CV-TS, 20 ES-TA, 7 ES-TF) were included in the study. They presented a high-risk profile (age 83.3 ± 5.4 years; logistic EuroSCORE 23.3 ± 12.3%) and important comorbidity. In-hospital mortality was 3.4%. Total cost of hospitalization was, on average, €35.841 (range €27.267-69.744) of which 68% was attributable to the procedure. A huge variation in costs was observed among different treatment groups. Patients treated with transfemoral implant (CV-TF: €33.977; ES-TF: €31.442) were on average less expensive than others (CV-TS: €37.035; ES-TA: €41.139). Our findings show that treating patients with TAVI places a heavy burden on hospital budget. Hence, due to the shortage of financial resources, affordability of TAVI requires further attention.

  13. Replica sizing strategy for aortic valve replacement improves haemodynamic outcome of the epic supra valve.

    Science.gov (United States)

    Gonzalez-Lopez, David; Faerber, Gloria; Diab, Mahmoud; Amorim, Paulo; Zeynalov, Natig; Doenst, Torsten

    2017-10-01

    Current sizing strategies suggest valve selection based on annulus diameter despite supra-annular placement of biological prostheses potentially allowing placement of a larger size. We assessed the frequency of selecting a larger prosthesis if prosthesis size was selected using a replica (upsizing) and evaluated its impact on haemodynamics. We analysed all discharge echocardiograms between June 2012 and June 2014, where a replica sizer was used for isolated aortic valve replacement (Epic Supra: 266 patients, Trifecta: 49 patients). Upsizing was possible in 71% of the Epic Supra valves (by 1 size: 168, by 2 sizes: 20) and in 59% of the Trifectas (by 1 size: 26, by 2 sizes: 3). Patients for whom upsizing was possible had the lowest pressure gradients within their annulus size groups. The difference was significant in annulus diameters of 21-22 or 25-26 mm (Epic Supra) and 23-24 mm (Trifecta). Trifecta gradients were the lowest. However, the ability to upsize the Epic Supra by 2 sizes eliminated the differences between Epic Supra and Trifecta. Upsizing did not cause intraoperative complications. Using replica sizers for aortic prosthesis size selection allows the implantation of bigger prostheses than recommended in most cases and reduces postoperative gradients, specifically for Epic Supra. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Complete Resolution of a Large Bicuspid Aortic Valve Thrombus with Anticoagulation in Primary Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Rayan Jo Rachwan

    2017-09-01

    Full Text Available Native aortic valve thrombosis in primary antiphospholipid syndrome (APLS is a rare entity. We describe a 38-year-old man who presented with neurological symptoms and a cardiac murmur. Transthoracic echocardiography detected a large bicuspid aortic valve thrombus. Laboratory evaluation showed the presence of antiphospholipid antibodies. Anticoagulation was started, and serial echocardiographic studies showed complete resolution of the aortic valve vegetation after 4 months. The patient improved clinically and had no residual symptoms. This report and review of the literature suggests that vegetations in APLS can be treated successfully with conservative treatment, regardless of their size.

  15. Rapidly Progrediating Aortic Valve Infective Endocarditis in an Intravenous Drug User Treated by Antibiotics and Surgery

    Directory of Open Access Journals (Sweden)

    Malkia S. Swedi

    2012-01-01

    Full Text Available We report the case of a 22-year old male, a self-confessed recreational drug user who developed cardiogenic shock because of severe destruction of the aortic valve by rapidly progressive aortic valve endocarditis. The disease progression was acute; in a matter of days, the clinical manifestations were life-threatening necessitating urgent aortic valve replacement surgery. Cultivation revealed Streptococcus viridans as the microbial agent. Subsequent recovery with antibiotic treatment was without complication. This case report shows that immediately performed transoesophageal echocardiography and early consultation with a cardiac surgeon has fundamental importance in diagnosis and management of acute infective endocarditis in haemodynamically instable patients.

  16. Early identification of aortic valve sclerosis using iron oxide enhanced MRI.

    Science.gov (United States)

    Hamilton, Amanda M; Rogers, Kem A; Belisle, Andre J L; Ronald, John A; Rutt, Brian K; Weissleder, Ralph; Boughner, Derek R

    2010-01-01

    To test the ability of MION-47 enhanced MRI to identify tissue macrophage infiltration in a rabbit model of aortic valve sclerosis (AVS). The aortic valves of control and cholesterol-fed New Zealand White rabbits were imaged in vivo pre- and 48 h post-intravenous administration of MION-47 using a 1.5 Tesla (T) MR clinical scanner and a CINE fSPGR sequence. MION-47 aortic valve cusps were imaged ex vivo on a 3.0T whole-body MR system with a custom gradient insert coil and a three-dimensional (3D) FIESTA sequence and compared with aortic valve cusps from control and cholesterol-fed contrast-free rabbits. Histopathological analysis was performed to determine the site of iron oxide uptake. MION-47 enhanced the visibility of both control and cholesterol-fed rabbit valves in in vivo images. Ex vivo image analysis confirmed the presence of significant signal voids in contrast-administered aortic valves. Signal voids were not observed in contrast-free valve cusps. In MION-47 administered rabbits, histopathological analysis revealed iron staining not only in fibrosal macrophages of cholesterol-fed valves but also in myofibroblasts from control and cholesterol-fed valves. Although iron oxide labeling of macrophage infiltration in AVS has the potential to detect the disease process early, a macrophage-specific iron compound rather than passive targeting may be required. (c) 2009 Wiley-Liss, Inc.

  17. Aortic valve calcification as a predictor of location and severity of paravalvular regurgitation after transcatheter aortic valve implantation.

    Science.gov (United States)

    Koh, Ezra Y; Lam, Kayan Y; Bindraban, Navin R; Cocchieri, Riccardo; Planken, R Nils; Koch, Karel T; Baan, Jan; de Mol, Bas A; Marquering, Henk A

    2015-03-01

    To determine whether the location of aortic valve calcium (AVC) influences the location of paravalvular regurgitation (PR). PR is an adverse effect of transcatheter aortic valve implantation (TAVI) with a negative effect on long-term patient survival. The relationship between AVC and the occurrence of PR has been documented. However, the relationship between the distribution of AVC and the location of PR is still sparsely studied. The purpose of this study was to correlate severity and location of AVC with PR in patients treated with TAVI. Fifty-six consecutive patients who underwent transaortic or transapical TAVI and had preoperative computed tomography scans were included in this retrospective study. The volume, mass and location of AVC was determined and compared between patients with and without PR using a non-parametric t-test. Postoperative echocardiography was performed to determine the presence and location of PR, which was associated with the cusp with highest AVC using a χ(2) test. Valve deployment was successful in all 56 patients. PR was present in 38 patients (68%) after TAVI. There was a non-significantly higher volume of AVC in the PR group [214 (70-418) vs 371 (254-606) cm(3), P = 0.15]. AVC mass was significantly higher in patients with PR than in patients without PR [282 (188-421) vs 142 (48-259) mg, respectively, P = 0.043]. The location of PR was determined in 36 of these patients. Of these 36 patients, PR occurred at the cusp with the highest AVC in 20 patients (56%, χ(2) P = 0.030). In our population, PR was associated with greater AVC mass. Moreover, the location of PR was associated with the cusp with the highest amount of AVC. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Aortic root, not valve, calcification correlates with coronary artery calcification in patients with severe aortic stenosis

    DEFF Research Database (Denmark)

    Henein, Michael; Hällgren, Peter; Holmgren, Anders

    2015-01-01

    calcification (AVC), due to tissue similarity between the two types of vessel rather than with the valve leaflet tissue. MATERIAL AND METHODS: We studied 212 consecutive patients (age 72.5 ± 7.9 years, 91 females) with AS requiring aortic valve replacement (AVR) in two Heart Centers, who underwent multidetector......% of patients. CAC correlated with ARC (rho = 0.51, p patients had echocardiographic evidence of BAV and 123 TAV, who were older (p ... even after adjusting for age (p = 0.01). AVC score was associated with BAV after adjusting for age (p = 0.03) but ARC was not. Of the total cohort, 82 patients (39%) had significant coronary stenosis (>50%), but these were not different in the pattern of calcification from those without CAS. CAC...

  19. Asymptomatic papillary fibroelastoma of the Aortic valve in a young woman - a case report

    Directory of Open Access Journals (Sweden)

    Pitsis Antonis

    2009-09-01

    Full Text Available Abstract Echocardiography represents an invaluable diagnostic tool for the detection of intracardiac masses while simultaneously provides information about their size, location, mobility and attachment site as well as the presence and extent of any consequent hemodynamic derangement. A 29-year-old asymptomatic young woman with incidental transthoracic echocardiographic (TTE discovery of an aortic valve mass is presented. The 2-dimensional TTE showed a mobile, pedunculated mass, attached by a thin stalk to the aortic surface of the right coronary aortic cusp at the junction of its base with the anterior aortic wall. The importance of valve sparing tumour resection even in asymptomatic patients is emphasised.

  20. MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?

    NARCIS (Netherlands)

    Jurencak, T.; Turek, J.; Kietselaer, B.L.; Mihl, C.; Kok, M. de; Ommen, V.G. van; Garsse, L.A. van; Nijssen, E.C.; Wildberger, J.E.; Das, M.

    2015-01-01

    OBJECTIVES: To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root. METHODS: Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive

  1. Bicuspid aortic valve demonstrated with multislice computed tomography - a case report

    International Nuclear Information System (INIS)

    Marzec, M.; Lasek, W.; Serafin, Z.; Laskowska, K.; Swiatkiewicz, I.; Kubica, J.

    2004-01-01

    Bicuspid aortic valve (BAV) is one of the most common congenital heart defects and often coexists with other congenital abnormalities of the heart and great vessels. A standard diagnostic technique for valve imaging is echocardiography. However, suboptimal images may cause a diagnostic problem, especially in obese patients, women and in case of significant valve calcifications. The paper reports a case of a 27-year-old male patient with recurrent chest pain, appearing regardless of exertion. Routine physical examination, laboratory tests and echocardiography were negative. Multislice computed tomography (MSCT) showed normal coronary arteries and bicuspid aortic valve. The diagnostics of bicuspid aortic valve and the diagnostic value of MSCT are discussed. MSCT seems to be an important point in cardiac diagnostic algorithms, being an alternative modality for MR in BAV imaging. The presented case emphasizes the potential of MSCT for the diagnostics of cardiac valve congenital diseases. (author)

  2. The JUPITER registry: 1-year results of transapical aortic valve implantation using a second-generation transcatheter heart valve in patients with aortic stenosis.

    Science.gov (United States)

    Silaschi, Miriam; Treede, Hendrik; Rastan, Ardawan J; Baumbach, Hardy; Beyersdorf, Friedhelm; Kappert, Utz; Eichinger, Walter; Rüter, Florian; de Kroon, Thomas L; Lange, Rüdiger; Ensminger, Stephan; Wendler, Olaf

    2016-11-01

    Transcatheter aortic valve replacement (TAVR) is an established therapy for patients with aortic stenosis (AS) at high surgical risk. The JenaValve™ is a second-generation, self-expanding transcatheter heart valve (THV), implanted through transapical access (TA). During stent deployment, a specific 'clipping-mechanism' engages native aortic valve cusps for fixation. We present 1-year outcomes of the JUPITER registry, a post-market registry of the JenaValve for TA-TAVR. The JUPITER registry is a prospective, multicentre, uncontrolled and observational European study to evaluate the long-term safety and effectiveness of the Conformité Européenne-marked JenaValve THV. A total of 180 patients with AS were enrolled between 2012 and 2014. End-points were adjudicated in accordance with the valve academic research consortium document no. 1 definitions. The mean age was 80.4 ± 5.9 years and the mean logistic European system for cardiac operative risk evaluation I 21.2 ± 14.7%. The procedure was successful in 95.0% (171/180), implantation of a second THV (valve-in-valve) was performed in 2.2% (4/180) and conversion to surgical aortic valve replacement (SAVR) was necessary in 2.8% (5/180). No annular rupture or coronary ostia obstruction occurred. Two patients required SAVR after the day of index procedure (1.1%). All-cause mortality at 30 days was 11.1% (20/180), being cardiovascular in 7.2% (13/180). A major stroke occurred in 1.1% (2/180) at 30 days, no additional major strokes were observed during 1 year. All-cause mortality after 30 days was 13.1% (21/160) and combined efficacy at 1 year was 80.8% (122/151). At 1-year follow-up, no patient presented with more than moderate paravalvular leakage, while 2 patients (3.2%) showed moderate, 12 (19.0%) mild and 49 (82.4%) trace/none paravalvular regurgitation. In a high-risk cohort of patients undergoing TA-TAVR for AS, the use of the JenaValve THV is safe and effective. In patients at higher risk for coronary ostia

  3. Aortic root surgery in Marfan syndrome: Bentall procedure with the composite mechanical valved conduit versus aortic valve reimplantation with Valsalva graft.

    Science.gov (United States)

    Nardi, Paolo; Pellegrino, Antonio; Versaci, Francesco; Mantione, Ludmilla; Polisca, Patrizio; Iorio, Fiore S; Chiariello, Luigi

    2010-09-01

    The aim of the study is to compare mid-term results of Bentall aortic root replacement with composite mechanical valved conduit and aortic valve reimplantation procedure using the Valsalva graft for the treatment of aortic root aneurysm in patients with Marfan syndrome. We retrospectively compared data of 23 patients (mean age 38 + or - 14 years) who had undergone the Bentall procedure (group B) to those of 24 patients (mean age 36 + or - 12 years) who had undergone aortic valve reimplantation (group R) during a 14-year period. Follow-up (mean duration 65 + or - 44 months) was 100% complete. There were no operative deaths in either group. In group B, as compared with group R, preoperative aortic insufficiency (3.2 + or - 1.1/4 vs. 1.7 + or - 1.4/4, P Marfan patients, the Bentall procedure is associated with excellent mid-term outcome. The reimplantation technique, adopted for less dilated aortas, provides similarly satisfactory results. The Valsalva graft seems, with time, to allow a stable aortic valve function.

  4. Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    López-Aguilera, José; Segura Saint-Gerons, José María; Mazuelos Bellido, Francisco; Suárez de Lezo, Javier; Ojeda Pineda, Soledad; Pan Álvarez-Ossorio, Manuel; Romero Moreno, Miguel Ángel; Pavlovic, Djordje; Espejo Pérez, Simona; Suárez de Lezo, José

    2016-01-01

    Conduction disturbances often occur after CoreValve transcatheter aortic valve implantation. The aim was to analyze which cardiac conduction changes occur in patients with aortic stenosis treated with this type of prosthesis. A total of 181 patients with severe aortic stenosis treated with this prosthesis and studied by electrocardiography between April 2008 and December 2013 were selected. A subgroup of 137 (75.7%) consecutive patients was studied by intracardiac electrocardiogram before and after prosthesis implantation. The primary endpoint of the study was the need for a permanent pacemaker within 72 hours after prosthesis implantation. Numerous variables to predict this possibility were analyzed. Following implantation, PR and QRS intervals were increased from 173±47 ms to 190±52ms (P < .01) and from 98±22ms to 129±24 ms (P < .01), whereas the A-H and H-V intervals were prolonged from 95±39ms to 108±41ms (P < .01) and from 54±10ms to 66±23ms (P < .01). A total of 89 (49%) patients had new-onset left bundle-branch block, and 33 (25%) required a pacemaker within the first 72hours. The independent predictors for a pacemaker were baseline right bundle-branch block and prosthetic depth. Intracardiac intervals had no predictive value. In addition, 13 patients required a pacemaker after 72 hours. CoreValve prosthesis implantation has a high incidence of conduction disturbance, with left bundle-branch block being the most common. A total of 25% of patients required a permanent pacemaker. The need for a pacemaker was related to baseline right bundle-branch block and prosthetic depth. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Echocardiographic aortic valve calcification and outcomes in women and men with aortic stenosis.

    Science.gov (United States)

    Thomassen, Henrik K; Cioffi, Giovanni; Gerdts, Eva; Einarsen, Eigir; Midtbø, Helga Bergljot; Mancusi, Costantino; Cramariuc, Dana

    2017-10-01

    Sex differences in risk factors of aortic valve calcification (AVC) by echocardiography have not been reported from a large prospective study in aortic stenosis (AS). AVC was assessed using a prognostically validated visual score and grouped into none/mild or moderate/severe AVC in 1725 men and women with asymptomatic AS in the Simvastatin Ezetimibe in Aortic Stenosis study. The severity of AS was assessed by the energy loss index (ELI) taking pressure recovery in the aortic root into account. More men than women had moderate/severe AVC at baseline despite less severe AS by ELI (pAVC at baseline was independently associated with lower aortic compliance and more severe AS in both sexes, and with increased high-sensitive C reactive protein (hs-CRP) only in men (all pAVC at baseline was associated with a 2.5-fold (95% CI 1.64 to 3.80) higher hazard rate of major cardiovascular events in women, and a 2.2-fold higher hazard rate in men (95% CI 1.54 to 3.17) (both pAVC at baseline also predicted a 1.8-fold higher hazard rate of all-cause mortality in men (95% CI 1.04 to 3.06, pAVC scored by echocardiography has sex-specific characteristics in AS. Moderate/severe AVC is associated with higher cardiovascular morbidity in both sexes, and with higher all-cause mortality in men. ClinicalTrials.gov identifier: NCT00092677. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R. (Department of Diagnostic Radiology, Victoria General Hospital Halifax, Nova Scotia (Canada))

    1991-09-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess.

  7. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    International Nuclear Information System (INIS)

    O'Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R.

    1991-01-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess

  8. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Early and medium term results of the sleeve valve-sparing procedure for aortic root ectasia.

    Science.gov (United States)

    Gamba, Amando; Tasca, Giordano; Giannico, Floriana; Lobiati, Elisabetta; Skouse, Douglas; Galanti, Andrea; Martino, Antonello Stefano; Triggiani, Michele

    2015-04-01

    The aim of this retrospective study was to evaluate our experience of using a simplified aortic valve sleeve procedure to treat aortic root ectasia and aneurysms with or without aortic regurgitation. In experienced hands, 2 aortic valve-sparing procedures, ie, Yacoub and David, have yielded excellent long-term results in the treatment of aortic root aneurysms, with or without aortic regurgitation. However, these techniques are demanding and not widely used. Recently, a new and simplified valve-sparing technique, named "sleeve procedure," has been proposed, and has yielded encouraging early results. Ninety consecutive patients with aortic root aneurysms underwent sleeve procedures from October 2006 to October 2012. Follow-up data (clinical 100% complete and echocardiographic 93% complete) were acquired from our outpatient clinic or from the referring cardiologist. The mean age of the patients was 61.5 ± 12.5 years, 79% were male, 16 (18%) had a bicuspid valve, 3 had Marfan syndrome, and 2 had aortic dissection. Over a mean clinical follow-up of 34 ± 19 months, 2 patients died from noncardiac causes and 1 was reoperated on for the recurrence of aortic regurgitation. On follow-up echocardiography after a mean of 18 ± 9 months, aortic regurgitation was absent/negligible, mild or moderate in 62%, 37%, and 1% of patients, respectively, and the diameters of the annulus, Valsalva sinuses, and sinotubular junction were 27.3 + 2.2, 37.0 + 3.4, and 30.6 + 3.1 mm, respectively. Our encouraging early and medium term results suggest that the sleeve procedure is a safe and effective aortic valve-sparing technique for the treatment of aortic root ectasia and aneurysm. However, longer follow-up is needed in order to draw definitive conclusions. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Quality of Life After Transcatheter Aortic Valve Replacement: Prospective Data From GARY (German Aortic Valve Registry).

    Science.gov (United States)

    Lange, Rüdiger; Beckmann, Andreas; Neumann, Till; Krane, Markus; Deutsch, Marcus-André; Landwehr, Sandra; Kötting, Joachim; Welz, Armin; Zahn, Ralf; Cremer, Jochen; Figulla, Hans R; Schuler, Gerhard; Holzhey, David M; Funkat, Anne-Kathrin; Heusch, Gerd; Sack, Stefan; Pasic, Miralem; Meinertz, Thomas; Walther, Thomas; Kuck, Karl-Heinz; Beyersdorf, Friedhelm; Böhm, Michael; Möllmann, Helge; Hamm, Christian W; Mohr, Friedrich W

    2016-12-26

    This study sought to analyze health-related quality-of-life (HrQoL) outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) based on data from GARY (German Aortic Valve Registry). Typically, patients currently referred for and treated by TAVR are elderly with a concomitant variable spectrum of multiple comorbidities, disabilities, and limited life expectancy. Beyond mortality and morbidity, the assessment of HrQoL is of paramount importance not only to guide patient-centered clinical decision-making but also to judge this new treatment modality in this high-risk patient population. In 2011, 3,875 patients undergoing TAVR were included in the GARY registry. HrQoL was prospectively measured using the EuroQol 5 dimensions questionnaire self-complete version on paper at baseline and 1 year. Complete follow-up EuroQol 5 dimensions questionnaire evaluation was available for 2,288 patients (transvascular transcatheter aortic valve replacement [TAVR-TV]: n = 1,626 and transapical TAVR [TAVR-TA]: n = 662). In-hospital mortality was 5.9% (n = 229) and the 1-year mortality was 23% (n = 893). The baseline visual analog scale score for general health status was 52.6% for TAVR-TV and 55.8% for TAVR-TA and, in parallel to an improvement in New York Heart Association functional class, improved to 59.6% and 58.5% at 1 year, respectively (p regression analysis several pre- and post-operative factors were predictive for less pronounced HrQoL benefits. TAVR treatment led to improvements in HrQoL, especially in terms of mobility and usual activities. The magnitude of improvements was higher in the TAVR-TV group as compared to the TAVR-TA group. However, there was a sizable group of patients who did not derive any HrQoL benefits. Several independent pre- and post-operative factors were identified being predictive for less pronounced HrQoL benefits. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement.

    Science.gov (United States)

    Tavakoli, Reza; Leprince, Pascal; Gassmann, Max; Jamshidi, Peiman; Yamani, Nassrin; Amour, Julien; Lebreton, Guillaume

    2018-03-26

    Aortic valve stenosis has become the most prevalent valvular heart disease in developed countries, and is due to the aging of these populations. The incidence of the pathology increases with growing age after 65 years. Conventional surgical aortic valve replacement through median sternotomy has been the gold standard of patient care for symptomatic aortic valve stenosis. However, as the risk profile of patients worsens, other therapeutic strategies have been introduced in an attempt to maintain the excellent results obtained by the established surgical treatment. One of these approaches is represented by transcatheter aortic valve implantation. Although the outcomes of high-risk patients undergoing treatment for symptomatic aortic valve stenosis have improved with transcatheter aortic valve replacement, many patients with this condition remain candidates for surgical aortic valve replacement. In order to reduce the surgical trauma in patients who are candidates for surgical aortic valve replacement, minimally invasive approaches have garnered interest during the past decade. Since the introduction of right anterior thoracotomy for aortic valve replacement in 1993, right anterior mini-thoracotomy and upper hemi-sternotomy have become the predominant incisional approaches among cardiac surgeons performing minimal access aortic valve replacement. Beside the location of the incision, the arterial cannulation site represents the second major landmark of minimal access techniques for aortic valve replacement. The two most frequently used arterial cannulation sites include central aortic and peripheral femoral approaches. With the purpose of reducing surgical trauma in these patients, we have opted for a right anterior mini-thoracotomy approach with a central aortic cannulation site. This protocol describes in detail a technique for minimally invasive aortic valve replacement and provides recommendations for patient selection criteria, including cardiac computer

  12. Differences in performance of five types of aortic valve prostheses: haemodynamic assessment by dobutamine stress echocardiography.

    Science.gov (United States)

    Khoo, Jeffrey P; Davies, Joan E; Ang, Keng Leong; Galiñanes, Manuel; Chin, Derek T

    2013-01-01

    In patients being considered for aortic valve replacement, there remains controversy over which design or tissue offers the best performance. We aimed to evaluate in a single study the haemodynamic performances of five different widely used aortic valve prostheses: stentless porcine xenograft (Elan), stentless bovine pericardium (Pericarbon Freedom), stented porcine xenograft (Aspire), stented bovine pericardium (More) and mechanical (Ultracor). We also compared them with normal aortic valves and stenosed valves of variable severity. Preoperative echocardiography and dobutamine stress echocardiography at 1 year postoperatively were undertaken in 106 patients (n=18-24 from each group). Stentless bioprostheses, whether porcine or bovine, displayed superior haemodynamics across nearly all echocardiographic parameters: lower gradients, larger effective orifice area, higher dimensionless severity index (DSI) and lower resistance, when compared with stented or mechanical prostheses. Comparing both stented designs, bovine tissue performed the worst at rest, but with stress, there was no difference. The stress performances of the stentless bioprostheses were similar to the mildly stenosed native aortic valve, whereas the performances of the stented and mechanical prostheses resembled that of native valves with mild-to-moderate stenoses. Haemodynamic differences, however, did not translate into differences in left ventricular mass reduction at 1 year. Stentless bioprostheses displayed haemodynamics superior to stented or mechanical prostheses and had the closest performance to a normal, native aortic valve. Stress DSI data, least reliant on variable annulus/valve sizes and flow rates, provided the best haemodynamic discrimination.

  13. A correlative study of aortic valve rotation angle and thoracic aortic sizes using ECG gated CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saremi, Farhood, E-mail: fsaremi@usc.edu; Cen, Steven; Tayari, Nazila; Alizadeh, Houman; Emami, Amir; Lin, Leah; Fleischman, Fernando

    2017-04-15

    Objective: Various degrees of aortic valve rotation may be seen in individuals with no history of congenital cardiovascular malformations, but its association with aortic sizes has not been studied. Methods: Gated computed tomographic (CT angiograms in 217 patients were studied (66.7 ± 15; 22–97 years old)). Aortic diameters were determined at 5 anatomic locations. The length of the aorta from sinus to left subclavian artery was measured. The angle of valve rotation was recorded by measuring the angle between a line connecting the midpoint of the non-coronary sinus to the anterior commissure and another line along the interatrial septum. Rotation angles were correlated with aortic measurements. Patients were separated into two groups based on aortic sizes and into three groups based on age. The threshold for aortic dilatation was set at maximum ascending aorta diameter ≥40 mm (≥21 mm body surface area [BSA] indexed). Results: No significant difference in rotation angles was seen between the three age groups or between genders. Rotation angles were significantly correlated with maximal, average, and BSA adjustment of the aortic root and ascending aortic measurements. The aortic root angles were significantly different between the dilated versus nondilated aortas. There was no significant association between the rotation angles and age, length of ascending aorta, or diameters of descending aorta. Multivariate adaptive regression splines showed 25° of aortic root rotation as the diagnostic cut off for ascending aorta dilation. Above the 25° rotation, every 10° of increasing rotation was associated with a 3.78 ± 0.87 mm increase in aortic diameter (p < 0.01) and a 1.73 ± 0.25 times increased risk for having a dilated aorta (p < 0.01). Conclusion: Rotation angles of the aortic valve may be an independent non-invasive imaging marker for dilatation of the ascending aorta. Patients with increased rotation angle of the aortic valve may have higher risk for

  14. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  15. Clinical Relevance of Baseline TCP in Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Sannino, Anna; Stoler, Robert C; Hebeler, Robert F; Szerlip, Molly; Mack, Michael J; Grayburn, Paul A

    2017-10-01

    To investigate the influence of baseline thrombocytopenia (TCP) on short-term and long-term outcomes after transcatheter aortic valve replacement (TAVR). A total of 732 consecutive patients with severe, symptomatic aortic stenosis undergoing TAVR from January 2012 to December 2015 were included. Primary outcomes of interest were the relationship of baseline TCP with 30-day and 1-year all-cause mortality. Secondary outcomes of interest were procedural complications and in-hospital mortality in the same subgroups. The prevalence of TCP (defined as platelet count TCP (defined as platelet count TCP, moderate/severe TCP at baseline was associated with a significantly higher 30-day mortality (23.3% vs 2.3% and 3.1%, respectively; PTCP was an independent predictor of 30-day and 1-year mortality (hazard ratio [HR], 13.18; 95% confidence interval [CI], 4.49-38.64; PTCP is a strong predictor of mortality in TAVR patients, possibly identifying a specific subgroup of frail patients; therefore, it should be taken into account when addressing TAVR risk.

  16. Prognostic implications of left ventricular asymmetry in patients with asymptomatic aortic valve stenosis

    DEFF Research Database (Denmark)

    Sigvardsen, Per Ejlstrup; Larsen, Linnea Hornbech; Carstensen, Helle Gervig

    2018-01-01

    by multi-detector computed tomography according to previous definitions. Follow-up was conducted using electronic health records. Event-free survival was assessed using Cox proportional hazards models. Patients were followed for a median of 2.2 years (interquartile range 1.6-3.6). Indication for AVR......Aims: Left ventricular (LV) regional hypertrophy in the form of LV asymmetry is a common finding in patients with aortic valve stenosis. The aim of this study was to test the hypothesis that LV asymmetry predicts future symptomatic status and indication for aortic valve replacement (AVR......) in patients with asymptomatic aortic valve stenosis. Methods and results: In total, 114 patients with asymptomatic aortic valve stenosis (peak velocity > 2.5 m/s assessed by echocardiographic screening and LV ejection fraction > 50%) were enrolled in the study. LV asymmetry and LV geometry was assessed...

  17. Valve-Sparing Root Replacement Compared With Composite Valve Graft Procedures in Patients With Aortic Root Dilation.

    Science.gov (United States)

    Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E

    2016-10-25

    Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.

    Science.gov (United States)

    Tavakoli, Reza; Danial, Pichoy; Oudjana, Ahmed Hamid; Jamshidi, Peiman; Gassmann, Max; Leprince, Pascal; Lebreton, Guillaume

    2018-05-01

    Controversy still surrounds the optimal biological valve substitute for aortic valve replacement. In light of the current literature, we review advantages and optimal indications of stentless compared to stented aortic bio-prostheses. Recent meta-analyses, prospective randomized controlled trials and retrospective studies comparing the most frequently used stentless and stented aortic bio-prostheses were analyzed. In the present review, the types and implantation techniques of the bio-prosthesis that are seldom taken into account by most studies and reviews were integrated in the interpretation of the relevant reports. For stentless aortic root bio-prostheses, full-root vs. sub-coronary implantation offered better early transvalvular gradients, effective orifice area and left ventricular mass regression as well as late freedom from structural valve deterioration in retrospective studies. Early mortality and morbidity did not differ between the stentless and stented aortic bio-prostheses. Early transvalvular gradients, effective orifice area and regression of left ventricular hypertrophy were significantly better for stentless, especially as full-root, compared to stented bio-prostheses. The long-term valve-related survival for stentless aortic root and Toronto SPV bio-prosthesis was as good as that for stented pericardial aortic bio-prostheses. For full-root configuration this survival advantage was statistically significant. There seems to be not one but different ideal biological valve substitutes for different subgroups of patients. In patients with small aortic root or exposed to prosthesis-patient mismatch full-root implantation of stentless bio-prostheses may better meet functional needs of individual patients. Longer follow-ups on newer generation of stented bio-prostheses are needed for comparison of their hemodynamic performance with stentless counterparts especially in full-root configuration.

  19. Optimal timing of valve replacement in asymptomatic severe aortic stenosis.

    Science.gov (United States)

    Bilen, Emine; Ipek, Gökürk; Ayhan, Huseyin; Nacar, Alper Bugra; Kasapkara, Haci Ahmet; Sani, Cenk; Basbug, Serdar; Kurt, Mustafa; Bozkurt, Engin

    2014-09-01

    Patients with asymptomatic severe aortic stenosis (AS) constitute a heterogeneous group which includes not only certain cases who are at high risk of sudden death and valve-related heart failure, but also those at low risk for these events. Degenerative AS, which includes a majority of patients with AS, is characterized by stricture of the valve, increased arterial stiffness, and diverse left ventricular response to the valvular plus arterial vascular load. In addition to using traditional primary parameters, the severity of AS and the total left ventricular load should be assessed using new measures such as energy loss index and valvulo-arterial impedance. Natriuretic peptide levels and global longitudinal strain imaging may also be used as secondary parameters to obtain information about left ventricular systolic function, although these parameters do not correlate with the severity of AS. Exercise stress testing and exercise echocardiography are also beneficial when assessing the patient if they are symptomatic, and for determining valvular and left ventricular contractile reserves. The aim of this review was to emphasize the importance of risk stratifications in asymptomatic severe AS cases, and to assess the severity of AS using not only conventional methods but also new methods on which much emphasis has been placed during recent years.

  20. Transesophageal echocardiography for cardiac thromboembolic risk assessment in patients with severe, symptomatic aortic valve stenosis referred for potential transcatheter aortic valve implantation.

    Science.gov (United States)

    Lenders, Guy D; Paelinck, Bernard P; Wouters, Kristien; Claeys, Marc J; Rodrigus, Inez E; Van Herck, Paul L; Vrints, Christiaan J; Bosmans, Johan M

    2013-05-15

    Stroke is a devastating complication after transcatheter aortic valve implantation (TAVI) and might partially be related to cardiac embolization. The aim of this single-center prospective study was to determine the incidence of intracardiac thrombi and left atrial spontaneous echo contrast (SEC), both known predictors of cardiac embolic stroke, in patients referred for potential TAVI. One hundred four consecutive patients with severe symptomatic aortic valve stenosis and at high or very high risk for surgery were included and underwent transesophageal echocardiography. In 11 patients (10.6%), intracardiac thrombi were detected, and 25 patients (24%) showed dense grade 2 SEC. Atrial fibrillation (p risk patients with severe aortic valve stenosis referred for potential TAVI is high and can accurately be detected using transesophageal echocardiography. Systematic thromboembolic evaluation using transesophageal echocardiography is thus recommended in patients referred for TAVI. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Normal and stenotic human aortic valve opening: in vitro assessment of orifice area changes with flow.

    Science.gov (United States)

    Montarello, J K; Perakis, A C; Rosenthal, E; Boyd, E G; Yates, A K; Deverall, P B; Sowton, E; Curry, P V

    1990-06-01

    The ability to measure aortic valve area clinically has emphasized the need to understand the changes in aortic valve orifice area during flow. To compare the performance of normal and stenotic human aortic valves we used a pulsatile flow model that simulated in vivo flow conditions. Five normal autopsy specimens and 15 stenotic valves removed at operation were mounted into the model. Valve function was assessed by analysis of video recordings of valve leaflet motion during flow. Over the flow rates tested normal valves demonstrated a linear increase in orifice area. There was no resistance to leaflet opening and valve closure was rapid. The majority of stenotic valves demonstrated an increase in orifice area at low flow rates. No valve showed any increase in maximal area beyond flow rates of 3 l min-1. Increased leaflet resistance of these abnormal valves resulted in notably slower opening and closing rates. In patients with a high cardiac output and severe stenosis, overestimation of the anatomic orifice area derived by the Gorlin equation can result. This is not related to variability in maximal orifice area.

  2. Form Follows Function: Advances in Trilayered Structure Replication for Aortic Heart Valve Tissue Engineering

    Science.gov (United States)

    Simionescu, Dan T.; Chen, Joseph; Jaeggli, Michael; Wang, Bo; Liao, Jun

    2013-01-01

    Tissue engineering the aortic heart valve is a challenging endeavor because of the particular hemodynamic and biologic conditions present in the native aortic heart valve. The backbone of an ideal valve substitute should be a scaffold that is strong enough to withstand billions of repetitive bending, flexing and stretching cycles, while also being slowly degradable to allow for remodeling. In this review we highlight three overlooked aspects that might influence the long term durability of tissue engineered valves: replication of the native valve trilayered histoarchitecture, duplication of the three-dimensional shape of the valve and cell integration efforts focused on getting the right number and type of cells to the right place within the valve structure and driving them towards homeostatic maintenance of the valve matrix. We propose that the trilayered structure in the native aortic valve that includes a middle spongiosa layer cushioning the motions of the two external fibrous layers should be our template for creation of novel scaffolds with improved mechanical durability. Furthermore, since cells adapt to micro-loads within the valve structure, we believe that interstitial cell remodeling of the valvular matrix will depend on the accurate replication of the structures and loads, resulting in successful regeneration of the valve tissue and extended durability. PMID:23355946

  3. Form Follows Function: Advances in Trilayered Structure Replication for Aortic Heart Valve Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Dan T. Simionescu

    2012-01-01

    Full Text Available Tissue engineering the aortic heart valve is a challenging endeavor because of the particular hemodynamic and biologic conditions present in the native aortic heart valve. The backbone of an ideal valve substitute should be a scaffold that is strong enough to withstand billions of repetitive bending, flexing and stretching cycles, while also being slowly degradable to allow for remodeling. In this review, we highlight three overlooked aspects that might influence the long term durability of tissue engineered valves: (i replication of the native valve trilayered histoarchitecture, (ii duplication of the three-dimensional shape of the valve, (iii and cell integration efforts focused on getting the right number and type of cells to the right place within the valve structure and driving them towards homeostatic maintenance of the valve matrix. We propose that the trilayered structure in the native aortic valve that includes a middle spongiosa layer cushioning the motions of the two external fibrous layers should be our template for creation of novel scaffolds with improved mechanical durability. Furthermore, since cells adapt to micro-loads within the valve structure, we believe that interstitial cell remodeling of the valvular matrix will depend on the accurate replication of the structures and loads, resulting in successful regeneration of the valve tissue and extended durability.

  4. Patient-prosthesis mismatch and reduction in left ventricular mass after aortic valve replacement

    DEFF Research Database (Denmark)

    Kandler, Kristian; Møller, Christian H; Hassager, Christian

    2013-01-01

    The presence of patient-prosthesis mismatch (PPM) after aortic valve replacement may influence patient survival. We examined the relationship between PPM and changes in left ventricular mass index at 3 months follow-up and also overall survival.......The presence of patient-prosthesis mismatch (PPM) after aortic valve replacement may influence patient survival. We examined the relationship between PPM and changes in left ventricular mass index at 3 months follow-up and also overall survival....

  5. Transcatheter aortic valve implantation under conscious sedation – the first Indian experience

    Directory of Open Access Journals (Sweden)

    Syed Maqbool

    2014-03-01

    Full Text Available Transcatheter aortic valve implantation (TAVI is maturing strongly as an alternative to surgical aortic valve replacement (SAVR in patients who are inoperable/high risk for open heart surgery. General anesthesia (GA is the usual mode of anesthesia in these patients, but local anesthesia with conscious sedation (LACS has recently been described as a safe alternative with some added advantages. We report 2 cases who were unfit for GA and were done successfully under LACS.

  6. Transcatheter aortic valve implantation under conscious sedation – the first Indian experience

    Science.gov (United States)

    Maqbool, Syed; Kumar, Vijay; Rastogi, Vishal; Seth, Ashok

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) is maturing strongly as an alternative to surgical aortic valve replacement (SAVR) in patients who are inoperable/high risk for open heart surgery. General anesthesia (GA) is the usual mode of anesthesia in these patients, but local anesthesia with conscious sedation (LACS) has recently been described as a safe alternative with some added advantages. We report 2 cases who were unfit for GA and were done successfully under LACS. PMID:24814117

  7. Aorto-right ventricular fistula: a complication of aortic valve replacement.

    Science.gov (United States)

    Najib, Mohammad Q; Ng, Daniel; Vinales, Karyne L; Chaliki, Hari P

    2012-01-01

    The occurrence of aorto-right ventricular (aorto-RV) fistula after prosthetic aortic valve replacement is rare. Transthoracic echocardiography (TTE) with color-flow Doppler, transesophageal echocardiography (TEE), or both may be required for diagnosis. A 42-year-old woman sought care for palpitations and dyspnea due to atrial flutter 2 weeks after prosthetic aortic valve replacement and graft replacement of the ascending aorta. TTE and TEE revealed left-to-right shunt due to aorto-RV fistula.

  8. Bicuspid Aortic Valve and Thoracic Aortic Aneurysm: Three Patient Populations, Two Disease Phenotypes, and One Shared Genotype

    Directory of Open Access Journals (Sweden)

    Robert B. Hinton

    2012-01-01

    Full Text Available Bicuspid aortic valve (BAV and thoracic aortic aneurysm (TAA are two discrete cardiovascular phenotypes characterized by latent progressive disease states. There is a clear association between BAV and TAA; however the nature and extent of this relationship is unclear. There are both distinct and overlapping developmental pathways that have been established to contribute to the formation of the aortic valve and the aortic root, and the mature anatomy of these different tissue types is intimately intertwined. Likewise, human genetics studies have established apparently separate and common contributions to these clinical phenotypes, suggesting complex inheritance and a shared genetic basis and translating 3 patient populations, namely, BAV, TAA, or both, into a common but diverse etiology. A better understanding of the BAV-TAA association will provide an opportunity to leverage molecular information to modify clinical care through more sophisticated diagnostic testing, improved counseling, and ultimately new pharmacologic therapies.

  9. A computational model of aging and calcification in the aortic heart valve.

    Directory of Open Access Journals (Sweden)

    Eli J Weinberg

    Full Text Available The aortic heart valve undergoes geometric and mechanical changes over time. The cusps of a normal, healthy valve thicken and become less extensible over time. In the disease calcific aortic stenosis (CAS, calcified nodules progressively stiffen the cusps. The local mechanical changes in the cusps, due to either normal aging or pathological processes, affect overall function of the valve. In this paper, we propose a computational model for the aging aortic valve that connects local changes to overall valve function. We extend a previous model for the healthy valve to describe aging. To model normal/uncomplicated aging, leaflet thickness and extensibility are varied versus age according to experimental data. To model calcification, initial sites are defined and a simple growth law is assumed. The nodules then grow over time, so that the area of calcification increases from one model to the next model representing greater age. Overall valve function is recorded for each individual model to yield a single simulation of valve function over time. This simulation is the first theoretical tool to describe the temporal behavior of aortic valve calcification. The ability to better understand and predict disease progression will aid in design and timing of patient treatments for CAS.

  10. No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav Hørsted; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    OBJECTIVES: Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) for severe aortic valve stenosis (AVS) is common, but less common after transcatheter aortic valve replacement (TAVR) in patients considered at high risk for death after surgery. The objectives of this st......OBJECTIVES: Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) for severe aortic valve stenosis (AVS) is common, but less common after transcatheter aortic valve replacement (TAVR) in patients considered at high risk for death after surgery. The objectives...... for TAVR, and younger age and higher body mass index for SAVR. At 2 years, there were numerical but no statistically significant differences between both TAVR and SAVR patients with severe and no severe PPM for MACCE (0.0 vs 12.8% for TAVR; P = 0.13, and 13.5 vs 7.0% for SAVR; P = 0.27), number of cardiac...

  11. The Perceval Sutureless Aortic Valve: Review of Outcomes, Complications, and Future Direction.

    Science.gov (United States)

    Powell, Ramsey; Pelletier, Marc P; Chu, Michael W A; Bouchard, Denis; Melvin, Kevin N; Adams, Corey

    Surgical aortic valve replacement with a stented prosthesis has been the standard of care procedure for aortic stenosis. The Perceval (LivaNova, London, United Kingdom) is a sutureless aortic valve bioprosthesis currently implanted in more than 20,000 patients. The purpose of this article was to review the literature available after 9 years of clinical experience of the Perceval aortic valve. PubMED, Embase, and the Cochrane Library databases were searched. A meta-analysis of summary statistics from individual studies was conducted. A total of 333 studies were identified and 84 studies were included. Thirty-day mortality and 5-year survival ranged from 0% to 4.9% and 71.3% to 85.5%, respectively. Compared with stented prosthesis, pooled analysis demonstrated a statistically significant reduction in aortic cross-clamp and cardiopulmonary bypass times (minutes) with Perceval (38.6 vs 63.3 and 61.4 vs 84.9, P < 0.00001, respectively). Compared with transcatheter aortic valve implantation, pooled analysis demonstrated a statistically significant reduction with Perceval in paravalvular leakage (1.26% vs 14.31%) and early mortality (2.3% vs 6.9%). Favorable hemodynamics, acceptable valve durability, and ease of implantation in minimally invasive cases were reported as benefits. A trend toward increased rates of permanent pacemaker implantation and low postoperative platelet count were identified. Special use and off-label procedures described included bicuspid aortic valves, valve-in-valve for homograft and stentless prosthesis failure, concomitant valvular procedures, porcelain aorta, and endocarditis. The Perceval valve has shown safe clinical and hemodynamic outcomes. Outcomes support its continued usage and potential expansion.

  12. [Transcatheter aortic valve implantation versus aortic valve replacement: cost analysis from the regional health service and hospital perspectives].

    Science.gov (United States)

    Berti, Elena; Fortuna, Daniela; Bartoli, Simona; Ciuca, Cristina; Orlando, Anna; Scondotto, Salvatore; Agabiti, Nera; Salizzoni, Stefano; Aranzulla, Tiziana Claudia; Gandolfo, Caterina; De Palma, Rossana; Saia, Francesco

    2016-12-01

    The aim of this study was to estimate the cost of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (AVR) procedures, together with the cost of the first-year hospitalizations following the index ones, in 4 Italian regions where diffusion level of TAVI and coverage decisions are different. The cost analysis was performed evaluating 372 patients enrolled consecutively from December 1, 2012 to September 30, 2015. The index hospitalization cost was calculated both from the hospital perspective through a full-costing approach and from the regional healthcare service perspective by applying the regional reimbursement tariffs. The follow-up costs were calculated for one year after the index hospitalization, from the regional healthcare sservice perspective, through the identification of hospital admissions for cardiovascular pathologies after the index hospitalization and computation of the relative regional tariffs. The mean hospitalization cost was € 32 120 for transfemoral TAVI (232 procedures), € 35 958 for transapical TAVI (31 procedures) and € 17 441 for AVR (109 procedures). From the regional healthcare service perspective, the mean transfemoral TAVI cost was € 29 989, with relevant regional variability (range from € 19 987 to € 36 979); the mean transapical TAVI cost was € 39 148; the mean AVR cost was € 32 020. The mean follow-up costs were € 2294 for transfemoral TAVI, € 2335 for transapical TAVI, and € 2601 for AVR. In our study, transapical TAVI resulted more expensive than transfemoral TAVI, while surgical AVR was cheaper than both (less than 40%). Costs of the transfemoral approach showed great variability between participating regions, probably due to different hospital costs, logistics, patients' selection and reimbursement policy. A central level of control would be appropriate to avoid unjustified differences in access to innovative procedures between different Italian regions.

  13. Midterm outcome of valve-sparing aortic root replacement in inherited connective tissue disorders.

    Science.gov (United States)

    Tanaka, Hiroshi; Ogino, Hitoshi; Matsuda, Hitoshi; Minatoya, Kenji; Sasaki, Hiroaki; Iba, Yutaka

    2011-11-01

    This study determined the midterm outcome of valve-sparing aortic root replacement for patients with inherited connective tissue disorders. From 1993 to 2008, 94 patients underwent valve-sparing aortic root replacement. Sixty patients (64%), average age 33 years (range, 15 to 61 years), had inherited connective tissue disorders: Marfan syndrome, 54 (92%); Loeys-Dietz syndrome, 5 (8%); and smooth muscle α-actin (ACTA2) mutation in 1. Median preoperative sinus diameter was 52 mm (range, 42 to 76 mm), and moderate/severe aortic regurgitation was present in 14 (23%). Seven (12%, 1993 to 1999) underwent remodeling procedures, and 53 had reimplantation procedures. Cusp repair was performed in 4. Median follow-up was 55 months (range, 1 to 149 months). There were 15 patients in the early term (1993 to 2000) and 45 in the late term (2001 to 2008). Four late deaths occurred (cardiac, 3; aortic, 1), with 10-year survival of 86%. Rates of freedom from aortic valve replacement at 5 and 10 years were 85% and 58% in remodeling and 96% and 58% in reimplantation. Risk factors for reoperations were postprocedure intraoperative aortic insufficiency greater than mild (p = 0.046), remodeling procedure (p = 0.016), and early term (p = 0.0002). One patient (2%) with none/trivial postprocedure aortic insufficiency required aortic valve replacement. Freedom from reoperation in patients with none/trivial postprocedure aortic insufficiency at 5 and 10 years was 100% and 67%. Meticulous control of aortic insufficiency during operation would bring favorable midterm durability in valve-sparing aortic root replacement using a reimplantation technique, even in patients with inherited connective tissue disorders. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Quantification of aortic valve area and left ventricular muscle mass in healthy subjects and patients with symptomatic aortic valve stenosis by MRI.

    Science.gov (United States)

    Haimerl, J; Freitag-Krikovic, A; Rauch, A; Sauer, E

    2005-03-01

    MRI allows visualization and planimetry of the aortic valve orifice and accurate determination of left ventricular muscle mass, which are important parameters in aortic stenosis. In contrast to invasive methods, MRI planimetry of the aortic valve area (AVA) is flow independent. AVA is usually indexed to body surface area. Left ventricular muscle mass is dependent on weight and height in healthy individuals. We studied AVA, left ventricular muscle mass (LMM) and ejection fraction (EF) in 100 healthy individuals and in patients with symptomatic aortic valve stenosis (AS). All were examined by MRI (1.5 Tesla Siemens Sonate) and the AVA was visualized in segmented 2D flash sequences and planimetry of the performed AVA was manually. The aortic valve area in healthy individuals was 3.9+/-0.7 cm(2), and the LMM was 99+/-27 g. In a correlation analysis, the strongest correlation of AVA was to height (r=0.75, pvalve stenosis, AVA was 1.0+/-0.35 cm(2), in correlation to cath lab r=0.72, and LMM was 172+/-56 g. We compared the AS patients results with the data of the healthy subjects, where the reduction of the AVA was 28+/-10% of the expected normal value, while LMM was 42% higher in patients with AS. There was no correlation to height, weight or BSA in patients with AS. With cardiac MRI, planimetry of AVA for normal subjects and patients with AS offered a simple, fast and non-invasive method to quantify AVA. In addition LMM and EF could be determined. The strong correlation between height and AVA documented in normal subjects offered the opportunity to integrate this relation between expected valve area and definitive orifice in determining the disease of the aortic valve for the individual patient. With diagnostic MRI in patients with AS, invasive measurements of the systolic transvalvular gradient does not seem to be necessary.

  15. Aortic valve-sparing operation in Marfan syndrome: what do we know after a decade?

    Science.gov (United States)

    Kallenbach, Klaus; Baraki, Hassina; Khaladj, Nawid; Kamiya, Hiroyuki; Hagl, Christian; Haverich, Axel; Karck, Matthias

    2007-02-01

    We assessed the outcome in patients with Marfan syndrome operated on exclusively with the aortic valve-sparing reimplantation technique for aortic root aneurysms during more than a decade. Between July 1993 and April 2005, the aortic valve-sparing reimplantation technique (David I) was used in 325 patients. In 59 patients with clinical evidence of Marfan syndrome, procedures were done for aortic root aneurysm (n = 55) or aortic dissection type A (n = 4). Their mean age was 30 +/- 12 years (range, 9 to 62 years), and 37 (63%) were male. Additional procedures were arch replacement in 4 patients, coronary artery bypass grafting in 1, mitral valve surgery in 9, and closure of atrial septal defect in 3. Mean follow-up was 54 +/- 37 months (range, 0 to 139 months). No patient died during the first 30 days postoperatively. Mean bypass time was 163 +/- 34 minutes (range, 99 to 248 minutes), and mean aortic cross clamp time was 126 +/- 28 minutes (range, 78 to 202 minutes). Four patients (6.8%) required rethoracotomy for postoperative bleeding. Five late deaths (8.5%) occurred during follow-up. Reoperation of the reconstructed valve was required in 7 patients. Freedom from reoperation was 88% +/- 5% at 5 years and 80% +/- 9% at 10 years. Mean grade of aortic insufficiency was 1.81 preoperatively compared with 0.20 early postoperatively (p valve should encourage use of this technique in patients with Marfan syndrome.

  16. Valve-sparing operation for aortic root aneurysm in patients with Marfan syndrome.

    Science.gov (United States)

    Wang, R; Ma, W G; Tian, L X; Sun, L Z; Chang, Q

    2010-03-01

    We report our experience with aortic valve-sparing procedures in patients with Marfan syndrome and aortic root aneurysm. Between August 2003 and July 2007, we performed aortic valve-sparing procedures in 20 patients with aortic root aneurysm resulting from Marfan syndrome. Mean age was 28 +/- 10 years (range, 10 to 57 years), and there were 9 females and 11 males. A reimplantation technique was used in 9 cases, a remodeling technique in 8 and a patch technique in 3 cases. Additional procedures included total aorta replacement in 1 patient, and aortic arch replacement plus stented elephant trunk in 2 patients. The mean follow-up time was 46 +/- 16 months (range, 17 to 64 months). No in-hospital or late death occurred. Reexploration for bleeding was required in one case on postoperative day 1. No valve-related complications occurred during the follow-up period. At the end of follow-up, trivial or no aortic regurgitation was demonstrated in 14 patients, mild in 4 patients, moderate in 1 and severe in 1. Two patients with moderate and severe aortic regurgitation required reoperation. The early and mid-term results of the valve-sparing operations were favorable, and the durability of the preserved valve should encourage use of this technique in patients with Marfan syndrome.

  17. Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation.

    Science.gov (United States)

    Vy, Phuoc; Auffret, Vincent; Castro, Miguel; Badel, Pierre; Rochette, Michel; Haigron, Pascal; Avril, Stéphane

    2018-02-27

    Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation). Copyright © 2018 John Wiley & Sons, Ltd.

  18. Prevalence and Prognostic Significance of Right Ventricular Systolic Dysfunction in Patients Undergoing Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E

    2016-07-01

    Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); Pvalve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.

  19. ACE inhibition attenuates uremia-induced aortic valve thickening in a novel mouse model

    DEFF Research Database (Denmark)

    Simolin, Mikko A; Pedersen, Tanja X; Bro, Susanne

    2009-01-01

    BACKGROUND: We examined whether impaired renal function causes thickening of the aortic valve leaflets in hyperlipidemic apoE-knockout (apoE-/-) mice, and whether the putative effect on the aortic valves could be prevented by inhibiting the angiotensin-converting enzyme (ACE) with enalapril. METH...... for investigating the mechanisms of uremia-induced aortic valve disease, and also provides an opportunity to study its pharmacologic prevention.......BACKGROUND: We examined whether impaired renal function causes thickening of the aortic valve leaflets in hyperlipidemic apoE-knockout (apoE-/-) mice, and whether the putative effect on the aortic valves could be prevented by inhibiting the angiotensin-converting enzyme (ACE) with enalapril....... METHODS: Thickening of the aortic valve leaflets in apoE-/- mice was induced by producing mild or moderate chronic renal failure resulting from unilateral nephrectomy (1/2 NX, n = 18) or subtotal nephrectomy (5/6 NX, n = 22), respectively. Additionally, the 5/6 NX mice were randomized to no treatment (n...

  20. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes.

    Science.gov (United States)

    Jose, John; Sulimov, Dmitriy S; El-Mawardy, Mohamed; Sato, Takao; Allali, Abdelhakim; Holy, Erik W; Becker, Björn; Landt, Martin; Kebernik, Julia; Schwarz, Bettina; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-04-10

    The aim of this study was to determine the incidence, characteristics, and treatment outcomes of patients diagnosed with clinical transcatheter heart valve thrombosis. Limited data exists on clinical or manifest transcatheter heart valve thrombosis. Prior studies have focused on subclinical thrombosis. A retrospective analysis was conducted of prospectively collected data from a single-center registry that included 642 consecutive patients who underwent transcatheter aortic valve replacement between 2007 and 2015 (305 patients had self-expanding valves; balloon-expandable, n = 281; mechanically expanding, n = 56). Long-term oral anticoagulation (OAC) was indicated in 261 patients, while 377 patients received dual-antiplatelet therapy post-procedure. All patients underwent scheduled clinical and echocardiographic follow-up. The overall incidence of clinical valve thrombosis was 2.8% (n = 18). No patient on OAC developed thrombosis. Of the detected thrombosis cases, 13 patients had balloon-expandable, 3 had self-expanding, and 2 had mechanically expanding valves. Thrombosis occurred significantly more often with balloon-expandable valves (odds ratio: 3.45; 95% confidence interval: 1.22 to 9.81; p = 0.01) and following valve-in-valve procedures (odds ratio: 5.93; 95% confidence interval: 2.01 to 17.51; p = 0.005). Median time to diagnosis of valve thrombosis was 181 days. The median N-terminal pro-brain natriuretic peptide level was 1,318 pg/ml (interquartile range: 606 to 1,676 pg/ml). The mean transvalvular gradient and valve area were 34 ± 14 mm Hg and 1.0 ± 0.46 cm 2 , respectively. Computed tomography showed hypoattenuating areas with reduced leaflet motion. Initiation of OAC resulted in significant reduction of transvalvular gradient and clinical improvement. No deaths were related to valve thrombosis. Clinical transcatheter heart valve thrombosis is more common than previously considered, characterized by imaging abnormalities and increased gradients

  1. Treatment of Symptomatic Severe Aortic Stenosis With a Novel Resheathable Supra-Annular Self-Expanding Transcatheter Aortic Valve System.

    Science.gov (United States)

    Manoharan, Ganesh; Walton, Antony S; Brecker, Stephen J; Pasupati, Sanjeevan; Blackman, Daniel J; Qiao, Hongyan; Meredith, Ian T

    2015-08-24

    The purpose of this study was to prospectively evaluate the safety and clinical performance of the CoreValve Evolut R transcatheter aortic valve replacement (TAVR) system (Medtronic, Inc., Minneapolis, Minnesota) in a single-arm, multicenter pivotal study in high- or extreme-risk patients with symptomatic aortic valve stenosis. Although outcomes following TAVR are improving, challenges still exist. The repositionable 14-F equivalent CoreValve Evolut R TAVR system was developed to mitigate some of these challenges. Suitable patients (n = 60) underwent TAVR with a 26- or 29-mm Evolut R valve. Primary safety endpoints were mortality and stroke at 30 days. Primary clinical performance endpoints were device success per the VARC-2 (Valve Academic Research Consortium-2) and the percent of patients with mild or less aortic regurgitation 24 h to 7 days post-procedure. Patients (66.7% female; mean age 82.8 ± 6.1 years; Society of Thoracic Surgeons Score 7.0 ± 3.7%) underwent TAVR via the transfemoral route in 98.3%, using a 29-mm valve in 68.3% of patients. All attempts at repositioning were successful. No death or stroke was observed up to 30 days. The VARC-2 overall device success rate was 78.6%. Paravalvular regurgitation post TAVR was mild or less in 96.6%, moderate in 3.4%, and severe in 0% at 30 days. Major vascular complications occurred in 8.3%, and permanent pacemaker implantation was required in 11.7% of patients. The repositionable 14-F equivalent Evolut R TAVR system is safe and effective at treating high-risk symptomatic aortic stenosis patients. Repositioning was successful when required in all patients, with low rates of moderate or severe paravalvular aortic regurgitation and low permanent pacemaker implantation. (The Medtronic CoreValve™ Evolut R™ CE Mark Clinical Study; NCT01876420). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty.

    Science.gov (United States)

    Campelo-Parada, Francisco; Nombela-Franco, Luis; Urena, Marina; Regueiro, Ander; Jiménez-Quevedo, Pilar; Del Trigo, María; Chamandi, Chekrallah; Rodríguez-Gabella, Tania; Auffret, Vincent; Abdul-Jawad Altisent, Omar; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Philippon, François; Pérez-Castellano, Nicasio; Puri, Rishi; Macaya, Carlos; Rodés-Cabau, Josep

    2018-03-01

    Little is known about the timing of onset and outcome of conduction abnormalities (CA) following balloon-expandable transcatheter aortic valve implantation. The aim of this study was to examine the timing of CA and determine the impact of balloon aortic valvuloplasty (BAV) on the persistence of these abnormalities. A total of 347 patients were included. Of these, 75 had a continuous electrocardiogram recording and a 6-lead electrocardiogram at each step of the procedure. In the transcatheter aortic valve implantation population undergoing continuous electrocardiogram monitoring, new-onset left bundle branch block (LBBB) or third-degree atrioventricular block occurred in 48 (64%) and 16 (21.3%) patients, with 51.5% of CA occurring before valve implantation. Left bundle branch block persisted more frequently at hospital discharge (53.8 vs 22.7%; P=.028) and at 1-month follow-up (38.5 vs 13.6%; P=.054) when occurring before valve implantation. Balloon aortic valvuloplasty prior to valve implantation was used in 264 (76.1%) patients, and 78 (22.5%) had persistent LBBB or complete atrioventricular block requiring pacemaker implantation. Persistent LBBB or unresolved atrioventricular block at 1 month occurred more frequently in the BAV group (76.1 vs 47.6%; P=.021), and the use of BAV was associated with a lack of CA resolution (OR, 3.5; 95%CI, 1.17-10.43; P=.021). In patients undergoing a balloon-expandable transcatheter aortic valve implantation, more than half of CA occurred before valve implantation. Early occurrence of CA was associated with a higher rate of persistence at 1-month follow-up. The use of BAV was associated with an increased risk of CA persistence. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Quantification of calcified particles in human valve tissue reveals asymmetry of calcific aortic valve disease development

    Directory of Open Access Journals (Sweden)

    Katsumi Yabusaki

    2016-11-01

    Full Text Available Recent studies indicated that small calcified particles observable by scanning electron microcopy (SEM may initiate calcification in cardiovascular tissues. We hypothesized that if the calcified particles precede gross calcification observed in calcific aortic valve disease (CAVD, they would exhibit a regional asymmetric distribution associated with CAVD development, which always initiates at the base of aortic valve leaflets adjacent to the aortic outflow in a region known as the fibrosa. Testing this hypothesis required counting the calcified particles in histological sections of aortic valve leaflets. SEM images, however, do not provide high contrast between components within images, making the identification and quantification of particles buried within tissue extracellular matrix difficult. We designed a new unique pattern matching-based technique to allow for flexibility in recognizing particles by creating a gap zone in the detection criteria that decreased the influence of non-particle image clutter in determining whether a particle was identified. We developed this flexible pattern particle labeling (FpPL technique using synthetic test images and human carotid artery tissue sections. A conventional image particle counting method (pre-installed in ImageJ did not properly recognize small calcified particles located in noisy images that include complex extracellular matrix structures, and other commonly used pattern matching methods failed to detect the wide variation in size, shape and brightness exhibited by the particles. Comparative experiments with the ImageJ particle counting method demonstrated that our method detected significantly more p<2*10-7 particles than the conventional method with significantly fewer p<0.0003 false positives and false negatives p<0.0003. We then applied the FpPL technique to CAVD leaflets and showed a significant increase in detected particles in the fibrosa at the base of the leaflets (p<0.0001, supporting

  4. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  5. Measures of right ventricular function after transcatheter versus surgical aortic valve replacement

    DEFF Research Database (Denmark)

    Grønlykke, Lars; Ihlemann, Nikolaj; Ngo, Anh Thuc

    2017-01-01

    OBJECTIVES: Describe changes in measures of right ventricular (RV) function in patients treated for aortic stenosis using open-chest surgery (SAVR) or transcatheter treatment (TAVR). METHODS: Patients in the Nordic Aortic Valve Intervention (NOTION) trial were randomized 1:1 to TAVR (n = 114...

  6. Meta-analysis of predictors of all-cause mortality after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Giordana, Francesca; D'Ascenzo, Fabrizio; Nijhoff, Freek; Moretti, Claudio; D'Amico, Maurizio; Biondi Zoccai, Giuseppe; Sinning, Jan Malte; Nickenig, George; van Mieghem, Nicolas M.; Chieffo, Adelaide; Dumonteil, Nicolas; Tchetche, Didier; Barbash, Israel M.; Waksman, Ron; D'Onofrio, Augusto; Lefevre, Thierry; Pilgrim, Thomas; Amabile, Nicolas; Codner, Pablo; Kornowski, Ran; Yong, Ze Yie; Baan, Jan; Colombo, Antonio; Latib, Azeem; Salizzoni, Stefano; Omedè, Pierluigi; Conrotto, Federico; La Torre, Michele; Marra, Sebastiano; Rinaldi, Mauro; Gaita, Fiorenzo

    2014-01-01

    The aim of this study was to identify predictors of 30-day and midterm mortality after transcatheter aortic valve implantation (TAVI) by means of a systemic review. TAVI was demonstrated to be safe and efficacious in patients with severe aortic stenosis. An accurate estimation of procedural risk of

  7. Continuous-Flow Cardiac Assistance: Effects on Aortic Valve Function in a Mock Loop

    NARCIS (Netherlands)

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-01-01

    Background. As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion-with resultant aortic regurgitation-has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we

  8. Expression of uPA, tPA, and PAI-1 in Calcified Aortic Valves

    Directory of Open Access Journals (Sweden)

    Najlah Kochtebane

    2014-01-01

    Full Text Available Purpose. Our physiopathological assumption is that u-PA, t-PA, and PAI-1 are released by calcified aortic valves and play a role in the calcification of these valves. Methods. Sixty-five calcified aortic valves were collected from patients suffering from aortic stenosis. Each valve was incubated for 24 hours in culture medium. The supernatants were used to measure u-PA, t-PA, and PAI-1 concentrations; the valve calcification was evaluated using biphotonic absorptiometry. Results. Aortic stenosis valves expressed normal plasminogen activators concentrations and overexpressed PAI-1 (u-PA, t-PA, and PAI-1 mean concentrations were, resp., 1.69 ng/mL ± 0.80, 2.76 ng/mL ± 1.33, and 53.27 ng/mL ± 36.39. There was no correlation between u-PA and PAI-1 (r=0.3 but t-PA and PAI-1 were strongly correlated with each other (r=0.6. Overexpression of PAI-1 was proportional to the calcium content of the AS valves. Conclusions. Our results demonstrate a consistent increase of PAI-1 proportional to the calcification. The overexpression of PAI-1 may be useful as a predictive indicator in patients with aortic stenosis.

  9. Augmented Reality System for Ultrasound Guidance of Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Currie, Maria E; McLeod, A Jonathan; Moore, John T; Chu, Michael W A; Patel, Rajni; Kiaii, Bob; Peters, Terry M

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) relies on fluoroscopy and nephrotoxic contrast medium for valve deployment. We propose an alternative guidance system using augmented reality (AR) and transesophageal echocardiography (TEE) to guide TAVI deployment. The goals of this study were to determine how consistently the aortic valve annulus is defined from TEE using different aortic valve landmarks and to compare AR guidance with fluoroscopic guidance of TAVI deployment in an aortic root model. Magnetic tracking sensors were integrated into the TAVI catheter and TEE probe, allowing these tools to be displayed in an AR environment. Variability in identifying aortic valve commissures and cuspal nadirs was assessed using TEE aortic root images. To compare AR guidance of TAVI deployment with fluoroscopic guidance, a TAVI stent was deployed 10 times in the aortic root model using each of the two guidance systems. Commissures and nadirs were both investigated as features for defining the valve annulus in the AR guidance system. The commissures were identified more consistently than the nadirs, with intraobserver variability of 2.2 and 3.8 mm, respectively, and interobserver variability of 3.3 and 4.7 mm, respectively. The precision of TAVI deployment using fluoroscopic guidance was 3.4 mm, whereas the precision of AR guidance was 2.9 mm, and its overall accuracy was 3.4 mm. This indicates that both have similar performance. Aortic valve commissures can be identified more reliably than cuspal nadirs from TEE. The AR guidance system achieved similar deployment accuracy to that of fluoroscopy while eliminating the use and consequences of nephrotoxic contrast and radiation.

  10. Significance of transesophageal echocardiography in the evaluation of aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Prcović Biljana

    2010-01-01

    Full Text Available Background/Aim. Transesophageal echocardiography (TEE is a relatively new diagnostic method offering better resolution of cardiac anatomy than the conventional transthoracal two-dimensional echocardiography (TTE. Clinical indications for TEE have been expanding, thus the technique as a diagnostic procedure is used in numerous cardiac diseases such as endocarditis, congenital heart defect, aortic dissection, prosthetic valves dysfunction, as well as in calculation of aortic valve surface in aortic stenosis. The aim of the study was to prove TEE as a more precise method in determination of the level of seriousness of aortic valve stenosis. Methods. All the patients went through TTE and TEE. Evaluating of the aortic valve surface was performed by the use of Gorlin's formula in TTE while it was planimetric in TEE examination. Results. Comparative analysis of all parameters obtained by TTE and TEE showed a difference between them. All the parameters values except that for surface area of the aortic valve orifice confluence were higher in TEE than in TTE examination, but no difference was statistically significant (p > 0.05; t-test for a dependant specimens. By the use of the TTE method, the size of aortic orifice stenosis was 1.22 ± 0.54 cm2, and by the TEE method it was 1.08 ± 0.54 cm2. Conclusion. Multiplain TEE is reliable in quantification of an aortic valve area in patients with aortic stenosis. It offers useful clinical information, particularly in patients with non-adequate evaluation with TTE, as well as in seriously ill patients or those with a confirmed valvular defect.

  11. Immediate results of aortic valve reconstruction by using autologous pericardium (Ozaki procedure

    Directory of Open Access Journals (Sweden)

    Е. В. Россейкин

    2016-08-01

    Full Text Available Aim: The study was designed to compare the immediate echocardiographic characteristics of aortic valve reconstruction by using autologous pericardium and the method proposed in 2007 by Shigeyuki Ozaki, as well as aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.Methods: Over a period from January 2014 to February 2016, 76 patients underwent aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II (n=41 and Carpentier-Edwards PERIMOUNT (n=35 at our hospital. 20 patients underwent the Ozaki procedure. These three groups of patients were assigned to the study. Demographic and preoperative indicators of patients from all three groups were homogeneous (р>0.05. The evaluation of the aortic valves replaced was carried out by echocardiography.Results: Echocardiography was performed before the procedure and in the early postoperative period. Statistical analysis using ANOVA showed significantly lower values of the aortic valve pressure gradient (p<0.001 and larger effective orifice area and indexed effective orifice area of the valve (p<0.001 in the group of the Ozaki procedure.Conclusion: According to echocardiography data, in the immediate postoperative period the Ozaki procedure is associated with lower mean and peak gradients of pressure on the aortic valve and larger effective orifice area and indexed effective orifice area of the valve, as compared with the frame-mounted biological aortic prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  12. Immediate results of aortic valve reconstruction by using autologous pericardium (Ozaki procedure

    Directory of Open Access Journals (Sweden)

    Е. В. Россейкин

    2016-11-01

    Full Text Available Aim. The study was designed to compare the immediate echocardiographic characteristics of aortic valve reconstruction by using autologous pericardium and the method proposed in 2007 by Shigeyuki Ozaki, as well as aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.Methods. Over a period from January 2014 to February 2016, 76 patients underwent aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II (n=41 and Carpentier-Edwards PERIMOUNT (n=35 at our hospital. 20 patients underwent the Ozaki procedure. These three groups of patients were assigned to the study. Demographic and preoperative indicators of patients from all three groups were homogeneous (р>0.05. The evaluation of the aortic valves replaced was carried out by echocardiography.Results. Echocardiography was performed before the procedure and in the early postoperative period. Statistical analysis using ANOVA showed significantly lower values of the aortic valve pressure gradient (p<0.001 and larger effective orifice area and indexed effective orifice area of the valve (p<0.001 in the group of the Ozaki procedure.Conclusion. According to echocardiography data, in the immediate postoperative period the Ozaki procedure is associated with lower mean and peak gradients of pressure on the aortic valve and larger effective orifice area and indexed effective orifice area of the valve, as compared with the frame-mounted biological aortic prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.Received 27 May 2016. Accepted 24 June 2016.Funding: The study had no sponsorship. Conflict of interest: The authors declare no conflict of interest.

  13. Left side approach for aortic valve replacement in patient with dextrocardia and situs inversus totalis

    Directory of Open Access Journals (Sweden)

    Salah E. Altarabsheh

    2017-10-01

    Full Text Available Aortic valve replacement in patients with dextrocardia and situs inversus totalis is technically challenging due to anatomical considerations. Modifications of the cannulation strategy and operative tool sets are helpful. We report a 47-year-old man who had dextrocardia with situs inversus totalis with severe aortic regurgitation. Our approach was precisely planned depending on the clear anatomy outlined by preoperative contrast-enhanced computed tomography of the chest. We used a surgical approach in which the main surgeon was standing on the left side of the patient. Left sided approach provided excellent exposure for aortic valve replacement in this case scenario.

  14. Bentall procedure using cryopreserved valved aortic homografts: mid- to long-term results.

    Science.gov (United States)

    Christenson, Jan T; Sierra, Jorge; Trindade, Pedro T; Dominique, Didier; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 +/- 21 years (range, 15-74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 +/- 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6-72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft.

  15. Del Nido cardioplegia for minimally invasive aortic valve replacement.

    Science.gov (United States)

    Koeckert, Michael S; Smith, Deane E; Vining, Patrick F; Ranganath, Neel K; Beaulieu, Thomas; Loulmet, Didier F; Zias, Elias; Galloway, Aubrey C; Grossi, Eugene A

    2018-02-01

    We analyzed the impact and safety of del Nido Cardioplegia (DNC) in patients undergoing minimally invasive aortic valve replacement (MIAVR). We analyzed all isolated MIAVR replacements from 5/2013-6/2015 excluding re-operative patients. The approach was a hemi-median sternotomy in all patients. Patients were divided into two cohorts, those who received 4:1 crystalloid:blood DNC solution and those in whom standard 1:4 Buckberg-based cardioplegia (WBC) was used. One-to-one propensity case matching of DNC to WBC was performed based on standard risk factors and differences between groups were analyzed using chi-square and non-parametric methods. MIAVR was performed in 181 patients; DNC was used in 59 and WBC in 122. Case matching resulted in 59 patients per cohort. DNC was associated with reduced re-dosing (5/59 (8.5%) versus 39/59 (61.0%), P DNC patients versus 33.9% (20/59) of WBC patients (P < 0.001). Median bypass and aortic cross-clamp times were similar. Clinical outcomes were similar with respect to post-operative hematocrit, transfusion requirements, need for inotropic/pressor support, duration of intensive care unit stay, re-intubation, length of stay, new onset atrial fibrillation, and mortality. Del Nido cardioplegia usage during MIAVR minimized re-dosing and the need for retrograde delivery. Patient safety was not compromised with this technique in this group of low-risk patients undergoing MIAVR. © 2018 Wiley Periodicals, Inc.

  16. David valve-sparing aortic root replacement: equivalent mid-term outcome for different valve types with or without connective tissue disorder.

    Science.gov (United States)

    Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Liang, David H; Beraud, Anne-Sophie; Stephens, Elizabeth H; Mitchell, R Scott; Miller, D Craig

    2013-01-01

    Although implicitly accepted by many that the durability of valve-sparing aortic root replacement in patients with bicuspid aortic valve disease and connective tissue disorders will be inferior, this hypothesis has not been rigorously investigated. From 1993 to 2009, 233 patients (27% bicuspid aortic valve, 40% Marfan syndrome) underwent Tirone David valve-sparing aortic root replacement. Follow-up averaged 4.7 ± 3.3 years (1102 patient-years). Freedom from adverse outcomes was determined using log-rank calculations. Survival at 5 and 10 years was 98.7% ± 0.7% and 93.5% ± 5.1%, respectively. Freedom from reoperation (all causes) on the aortic root was 92.2% ± 3.6% at 10 years; 3 reoperations were aortic valve replacement owing to structural valve deterioration. Freedom from structural valve deterioration at 10 years was 96.1% ± 2.1%. No significant differences were found in survival (P = .805, P = .793, respectively), reoperation (P = .179, P = .973, respectively), structural valve deterioration (P = .639, P = .982, respectively), or any other functional or clinical endpoints when patients were stratified by valve type (tricuspid aortic valve vs bicuspid aortic valve) or associated connective tissue disorder. At the latest echocardiographic follow-up (95% complete), 202 patients (94.8%) had none or trace aortic regurgitation, 10 (4.7%) mild, 0 had moderate to severe, and 1 (0.5%) had severe aortic regurgitation. Freedom from greater than 2+ aortic regurgitation at 10 years was 95.3% ± 2.5%. Six patients sustained acute type B aortic dissection (freedom at 10 years, 90.4% ± 5.0%). Tirone David reimplantation valve-sparing aortic root replacement in carefully selected young patients was associated with excellent clinical and echocardiographic outcome in patients with either a tricuspid aortic valve or bicuspid aortic valve. No demonstrable adverse influence was found for Marfan syndrome or connective tissue disorder on durability, clinical outcome

  17. Reliability and Identification of Aortic Valve Prolapse in the Horse

    Directory of Open Access Journals (Sweden)

    Hallowell Gayle D

    2013-01-01

    Full Text Available Abstract Background The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP using echocardiography in the horse. Results Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV was most commonly used for identification of AVP (46%; n=13. There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80 and good agreement between days and observers (kappa >0.6. The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8. Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9, with agreement for the identification of AVP (kappa>0.8. Short axis views of the AoV were used for identification of AVP by fewer respondents (23%, however provided less agreement for the identification of AVP (kappa>0.6 and only adequate agreement with observations made in long axis (kappa>0.5, with AVP being identified more often in short axis (92% compared to long axis (76%. Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings

  18. Basal longitudinal strain predicts future aortic valve replacement in asymptomatic patients with aortic stenosis

    DEFF Research Database (Denmark)

    Carstensen, Helle Gervig; Larsen, Linnea Hornbech; Hassager, Christian

    2016-01-01

    analysis and coronary angiography by MDCT. The combined endpoint was indication for aortic valve replacement (AVR) and sudden cardiac death. During a median follow-up of 2.3 years (interquartile range 1.7-3.6) 43 patients (41%) met the endpoint of indication for AVR. The basal (13.4 ± 3.1% vs. 15.7 ± 3.......1%) and mid-ventricular segments (14.9 ± 2.7% vs. 16.2 ± 2.9%) were significantly reduced, but with sparing of the apical segments, in patients who later underwent AVR. In various multivariable Cox regression models, including only BLS, but not GLS, remained an independent predictor of AVR. CONCLUSION...

  19. Double valve replacement for acute spontaneous left chordal rupture secondary to chronic aortic incompetence

    Directory of Open Access Journals (Sweden)

    McLenachan Jim

    2006-10-01

    Full Text Available Abstract A 54 years old male with undiagnosed chronic calcific degenerative aortic valve incompetence presented with acute left anterior chordae tendinae rupture resulting in severe left heart failure and cardiogenic shock. He was successfully treated with emergency double valve replacement using mechanical valves. The pathogenesis of acute rupture of the anterior chordae tendinae, without any evidence of infective endocarditis or ischemic heart disease seems to have been attrition of the subvalvular mitral apparatus by the chronic regurgitant jet of aortic incompetence with chronic volume overload. We review the literature with specific focus on the occurrence of this unusual event.

  20. Repair of a Mycotic Coronary Artery Aneurysm with an Intact Prosthetic Aortic Valve.

    Science.gov (United States)

    Ogawa, Mitsugu; Bell, David; Marshman, David

    2016-01-01

    We describe the case of a 75-year-old man with a mycotic right coronary artery aneurysm without evidence of prosthetic valve endocarditis. Eight years previously he had undergone coronary artery bypass surgery and aortic valve replacement. He presented with methicillin resistant staphylococcus aureus septicaemia after a prolonged hospital admission. Further investigation revealed a large mycotic right coronary artery aneurysm prompting urgent surgical repair. This case, of a mycotic coronary artery aneurysm in an atherosclerotic native coronary artery, is an extremely rare entity, which is further complicated by the presence of a prosthetic aortic valve. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  1. Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

    Science.gov (United States)

    Pouch, Alison M; Wang, Hongzhi; Takabe, Manabu; Jackson, Benjamin M; Sehgal, Chandra M; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2013-01-01

    The aortic valve has been described with variable anatomical definitions, and the consistency of 2D manual measurement of valve dimensions in medical image data has been questionable. Given the importance of image-based morphological assessment in the diagnosis and surgical treatment of aortic valve disease, there is considerable need to develop a standardized framework for 3D valve segmentation and shape representation. Towards this goal, this work integrates template-based medial modeling and multi-atlas label fusion techniques to automatically delineate and quantitatively describe aortic leaflet geometry in 3D echocardiographic (3DE) images, a challenging task that has been explored only to a limited extent. The method makes use of expert knowledge of aortic leaflet image appearance, generates segmentations with consistent topology, and establishes a shape-based coordinate system on the aortic leaflets that enables standardized automated measurements. In this study, the algorithm is evaluated on 11 3DE images of normal human aortic leaflets acquired at mid systole. The clinical relevance of the method is its ability to capture leaflet geometry in 3DE image data with minimal user interaction while producing consistent measurements of 3D aortic leaflet geometry.

  2. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

    Science.gov (United States)

    Schipke, Kimberly J; To, S D Filip; Warnock, James N

    2011-08-23

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed

  3. An in vitro experimental study of flow past aortic valve under varied pulsatile conditions

    Science.gov (United States)

    Zhang, Ruihang; Zhang, Yan

    2017-11-01

    Flow past aortic valve represents a complex fluid-structure interaction phenomenon that involves pulsatile, vortical, and turbulent conditions. The flow characteristics immediately downstream of the valve, such as the variation of pulsatile flow velocity, formation of vortices, distribution of shear stresses, are of particular interest to further elucidate the role of hemodynamics in various aortic diseases. However, the fluid dynamics of a realistic aortic valve is not fully understood. Particularly, it is unclear how the flow fields downstream of the aortic valve would change under varied pulsatile inlet boundary conditions. In this study, an in vitro experiment has been conducted to investigate the flow fields downstream of a silicone aortic valve model within a cardiovascular flow simulator. Phased-locked Particle Image Velocimetry measurements were performed to map the velocity fields and Reynolds normal and shear stresses at different phases in a cardiac cycle. Temporal variations of pressure across the valve model were measured using high frequency transducers. Results have been compared for different pulsatile inlet conditions, including varied frequencies (heart rates), magnitudes (stroke volumes), and cardiac contractile functions (shapes of waveforms).

  4. Contrast echocardiography: a novel technique for assessment of total aortic regurgitation following transapical aortic valve implantation.

    Science.gov (United States)

    Kukucka, Marian; Pasic, Miralem; Habazettl, Helmut; Unbehaun, Axel; Dreysse, Stephan; Drews, Thorsten; Hillebrandt, Thorsten; Mladenow, Alexander; Buz, Semih

    2015-01-01

    Aortic regurgitation (AR) is a possible complication following transcatheter aortic valve implantation (TAVI) which is associated with less-favourable outcomes. Quantification of total regurgitation caused by multiple, multidirectional jets remains controversial. The purpose of this study was to assess the usefulness of retrograde contrast echocardiography in quantification of total AR following TAVI and to evaluate its prognostic significance. In 245 patients following Edwards Sapien valve (Edwards Lifesciences, Irvine, CA, USA) implantation, we performed retrograde contrast transoesophageal echocardiography to quantify AR immediately after TAVI. The contrast (20 ml agitated gelatine polysuccinate, Gelafundin 4%, Braun, Melsungen, Germany) was injected as a bolus into the sinotubular junction of the aorta through a pigtail catheter. We measured the area of the regurgitant cloud during mid- to end-diastole. A regurgitant area of ≥3.8 cm2 was determined as an indicator of relevant AR. Sensitivity of this was compared through angiography and Doppler echocardiography. To assess whether AR identified by this novel method independently determined survival, a multivariate model was applied. Angiography, Doppler echocardiography and contrast echocardiography recognized 15, 23 and 56 patients with relevant regurgitation. Multivariate analysis including a regurgitant area of ≥3.8 cm2, New York Heart Association (NYHA) class IV, age and creatinine concentration identified a regurgitant area of ≥3.8 cm2 (P=0.027) as independent risk factor for 2-year survival. Contrast echocardiography is a simple method for quantification of total AR following TAVI and is more sensitive than angiography or Doppler echocardiography. Its clinical relevance is demonstrated by the impact of the AR detected by contrast echocardiography on survival. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Experiences of and Coping With Severe Aortic Stenosis Among Patients Waiting for Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Olsson, Karin; Näslund, Ulf; Nilsson, Johan; Hörnsten, Åsa

    2016-01-01

    Aortic stenosis (AS) is the most common valve disease in Western countries. Transcatheter aortic valve implantation (TAVI) has made it possible to treat patients with higher surgical risks. These patients are informed about their poor prognosis with only months or a few years to live without treatment. Because of their severe symptoms, limitations, and suffering, patients awaiting TAVI need special attention. The aim of this study is to describe patients' experiences of coping with severe AS and of waiting for TAVI. Swedish participants (n = 24; 9 women, 15 men) with a mean (SD) age of 80 (7.4) years who had been offered TAVI all agreed to participate in a presurgical interview. The interviews were recorded, transcribed verbatim, and analyzed using qualitative content analysis. The participants' experiences of coping with AS and awaiting TAVI were described by the main theme "living on the edge, but trying to stay in control," which comprised 3 categories: "trying to cope with physical symptoms and anxiety," "trying to preserve self and self-esteem despite life-threatening illness," and "trying to process the decision to undergo TAVI." Patients with AS and awaiting TAVI must cope with increasing symptoms and limitations in their social lives but still wish to be seen as the people they always have been. These patients may need extra support from healthcare personnel to process their experiences, which could help them to attach personal meaning to clinical information about the condition and its treatment that they could include in their decision about whether to undergo TAVI. Listening to patients' stories could help nurses and physicians to ensure that disease and treatment are meaningfully understood by the patient.

  6. Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis and Mitral Regurgitation.

    Science.gov (United States)

    Mavromatis, Kreton; Thourani, Vinod H; Stebbins, Amanda; Vemulapalli, Sreekanth; Devireddy, Chandan; Guyton, Robert A; Matsouaka, Roland; Ghasemzadeh, Nima; Block, Peter C; Leshnower, Bradley G; Stewart, James P; Rumsfeld, John S; Lerakis, Stamatios; Babaliaros, Vasilis

    2017-12-01

    Many patients undergoing transcatheter aortic valve replacement (TAVR) for aortic stenosis also have significant mitral regurgitation (MR). We sought to understand the association of concomitant MR with TAVR clinical outcomes, as well changes in MR after TAVR. Patients who underwent TAVR in the US Transcatheter Valve Therapy Registry from January 3, 2012, to December 31, 2013, were studied, with longer-term clinical outcomes from Center for Medicare Services data. Of 11,104 patients, 3,481 (31.3%) had moderate MR, and 605 (5.5%) had severe MR. At 1 year, mortality was 21.0%, 21.5%, 26.3%, and 28.0% (p < 0.0001) and heart failure (HF) rehospitalization was 13.9%, 15.8%, 20.3%, and 23.4% (p < 0.0001) in the no, mild, moderate, and severe MR patients, respectively. After adjustment for baseline differences, significant MR was associated with increased risk of 1-year mortality or HF rehospitalization, with a HR of 1.16 (95% CI, 0.99 to 1.35) for moderate MR and 1.21 (95% CI, 0.97 to 1.50) for severe MR, compared with no MR. MR improved early after TAVR grade ≥ 1 in 79% of the severe MR patients and 66% of the moderate MR patients. Patients whose baseline moderate or severe MR improved had lower mortality (p = 0.022) and HF rehospitalization (p < 0.001) compared with patients whose MR did not improve. Moderate or severe MR accompanying severe AS treated with TAVR is associated with increased mortality or HF rehospitalization. This increased risk may be attributable to the minority of patients whose MR does not improve, suggesting a potential role for surveillance and targeted intervention for those patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Common presentation of rare diseases: Aortic aneurysms & valves.

    Science.gov (United States)

    Arbustini, Eloisa; Favalli, Valentina; Di Toro, Alessandro; Giuliani, Lorenzo; Limongelli, Giuseppe

    2018-04-15

    The concept "common presentation of rare diseases" implies that rare diseases are masked by common phenotypic manifestations. This concept applies to both aneurysmal and valvular diseases that can be syndromic and non-syndromic. Syndromic disorders include genetic connective tissue diseases and chromosomal disorders that are diagnosed independently from the aneurysm or valve disease. Non-syndromic diseases, on the other hand, are defined by the presence of aneurysm or valve disease or both. The reasons for suspecting these rare diseases include young age, the absence of risk factors, a positive family history for aortic or valvular disease/event, and extra-cardiovascular traits for syndromes. The probands should receive genetic counseling, genetic testing [single gene in case of precise phenotyping addressing the gene to be tested, or multigene panels, in case of diseases with genetic heterogeneity], post-test counseling, clinical family screening and cascade genetic testing in relatives after the identification of a causative mutation. Segregation studies are essential in case of novel mutations, in particular non-truncation predicting variants. Clinical family screening of syndromic diseases is facilitated by the evaluation of non-cardiovascular traits; this supports early diagnosis and geno-phenotype correlation. Vice versa, family screening studies in non-syndromic aneurysmal and valvular diseases exclusively relies on CV imaging screening of relatives. In this context, conditions such as BAV and related aortopathy are easy to diagnose because BAV is present at birth while aortopathy usually develops during the life course. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Association of body mass index and visceral fat with aortic valve calcification and mortality after transcatheter aortic valve replacement: the obesity paradox in severe aortic stenosis

    Directory of Open Access Journals (Sweden)

    Jennifer Mancio

    2017-10-01

    Full Text Available Abstract Background Previous studies showed that metabolic syndrome is associated with aortic valve calcification (AVC and poor outcomes in aortic stenosis (AS. However, if these associations change and how body fat impacts the prognosis of patients in late stage of the disease have been not yet explored. Aims To determine the association of body mass index (BMI and visceral fat with AVC and mortality after transcatheter aortic valve replacement (TAVR. Methods This was a prospective cohort of 170 severe AS patients referred to TAVR. We quantified AVC mass score and fat depots including epicardial adipose tissue, intrathoracic fat, and abdominal visceral (VAF and subcutaneous fats by computed tomography. Fat depots were indexed to body surface area. All-cause and cardiovascular-related deaths after TAVR were recorded over a median follow-up of 1.2 years. Results Higher AVC mass was independently associated with low BMI and low VAF. All-cause mortality risk increased with the decrease of BMI and increment of VAF. A stratified analysis by obesity showed that in non-obese, VAF was inversely associated with mortality, whereas in obese, high VAF was associated with higher mortality (p value for interaction < 0.05. At long-term, hazard ratio [HR] with non-obese/low VAF was 2.3 (95% confidence interval [CI] 1.1–4.9; p = 0.021 and HR with obese/high VAF was 2.5 (95% CI 1.1–5.8; p = 0.031 compared with obese/low VAF patients. Conclusions In AS patients submitted to TAVR, BMI and VAF were inversely associated with AVC. Pre-intervention assessment of VAF by computed tomography may provide a better discrimination of mortality than BMI alone.

  9. [Anesthetic management and experience in the transcatheter implantation of the CoreValve(®) self-expanding aortic valve].

    Science.gov (United States)

    Fernández Suárez, F E; del Valle Fernández, R; González Alvarez, A; Sánchez Lasheras, J; Fernández Sánchez, L; Argüelles Tamargo, L

    2013-10-01

    To analyze the experience and anesthetic management in the transcatheter implantation of the CoreValve(®) self-expanding aortic valve, in a university tertiary hospital. Observational analytical review of data incorporated into a prospectively maintained database of 142 patients diagnosed with severe aortic stenosis who underwent implantation of a CoreValve(®) aortic self-expanding aortic valve between December 2007 and December 2012. The mean age of patients was 82.5±6.1 years and the logistic EuroSCORE was 14.9±11.2. General anesthesia was used in 107 patients (75.3%), with local anesthesia with sedation in 35 (24.6%). Local anesthesia and sedation was associated with a lower requirement of vasoactive drugs (P=.003) during implantation. No statistically significant differences were found between the 2 anesthetic techniques in the duration of the procedure, hospital stay, or morbimortality. The success rate was 97.1%. The most common complication was conduction disorders that required implantation of a permanent pacemaker in 46 patients (32.3%). There was no intraoperative mortality, and all-cause mortality at 30 days was 6.3%, with a one-year survival estimated by the Kaplan-Meier of 83.1%. This study confirms that in patients with severe aortic stenosis and high surgical risk, transcatheter implantation of aortic valve is a safe and effective alternative. Both, general anesthesia and local anesthesia with sedation are valid options, depending on the experience of the team. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  10. Optimal timing of aortic valve replacement in elderly patients with severe aortic stenosis.

    Science.gov (United States)

    Marumoto, Akira; Nakamura, Yoshinobu; Kishimoto, Yuichiro; Saiki, Munehiro; Nishimura, Motonobu

    2014-01-01

    The elderly population with severe aortic stenosis (AS) requiring aortic valve replacement (AVR) is increasing. The optimal timing of AVR in these patients has been under discussion. We retrospectively reviewed the data from severe AS patients (n = 84) who underwent AVR with/without concomitant procedures from 2005 to 2010. The symptom status, preoperative data, operative outcome, late survival and freedom from cardiac events were compared between elderly patients (age ≥80 years [n = 31]) and younger patients (age <80 years [n = 53]). The operative mortality in elderly patients (3.2 %) and younger patients (3.8 %) was comparable. The symptoms in elderly patients were more severe and hospitalized heart failure (HF) was more frequently noted as the primary symptom (p = 0.017). Patients with and without hospitalized HF differed significantly in late survival and freedom from cardiac events (p = 0.001), but advanced age had no significant effect. The results of a Cox proportional hazards analysis revealed that hospitalized HF was a significant predictor for cardiac events after AVR, irrespective of age (hazard ratio 6.93, 95 % confidence interval 1.83-26.26, p < 0.004). In elderly patients with severe AS, surgery should be recommended even in the presence of minimal symptoms and should be performed before the onset of life-threatening HF.

  11. A comparison of echocardiographic and electron beam computed tomographic assessment of aortic valve area in patients with valvular aortic stenosis

    NARCIS (Netherlands)

    Piers, Lieuwe H.; Dikkers, Riksta; Tio, Rene A.; van den Berg, Maarten P.; Willems, Tineke P.; Zijlstra, Felix; Oudkerk, Matthijs

    2007-01-01

    The purpose of this study was to compare electron beam computed tomography (EBT) with transthoracic echocardiography (TTE) in determining aortic valve area (AVA). Thirty patients (9 females, 21 males) underwent a contrast-enhanced EBT scan (e-Speed, GE, San Francisco, CA, USA) and TTE within 17 +/-

  12. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  13. Assessing Optimal Blood Pressure in Patients With Asymptomatic Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Nielsen, Olav W; Sajadieh, Ahmad; Sabbah, Muhammad

    2016-01-01

    BACKGROUND: Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. METHODS: A total of 1767 patients with asymptomatic aortic...... stenosis and no manifest atherosclerotic disease were analyzed. Outcomes were all-cause mortality, cardiovascular death, heart failure, stroke, myocardial infarction, and aortic valve replacement. BP was analyzed in Cox models as the cumulative average of serially measured BP and a time-varying covariate.......039). CONCLUSIONS: Optimal BP seems to be systolic BP of 130 to 139 mm Hg and diastolic BP of 70 to 90 mm Hg in these patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease or diabetes mellitus. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT...

  14. Transcatheter Aortic Valve Replacement Results in Improvement of Pulmonary Function in Patients With Severe Aortic Stenosis.

    Science.gov (United States)

    Gilmore, Richard C; Thourani, Vinod H; Jensen, Hanna A; Condado, Jose; Binongo, José Nilo G; Sarin, Eric L; Devireddy, Chandan M; Leshnower, Bradley; Mavromatis, Kreton; Syed, Amjad; Guyton, Robert A; Block, Peter C; Simone, Amy; Keegan, Patricia; Stewart, James; Rajaei, Mohammad; Kaebnick, Brian; Lerakis, Stamatios; Babaliaros, Vasilis C

    2015-12-01

    Chronic obstructive pulmonary disease (COPD) has been identified as a risk factor for morbidity and mortality after transcatheter aortic valve replacement (TAVR). We hypothesized that a portion of pulmonary dysfunction in patients with severe aortic stenosis may be of cardiac origin, and has potential to improve after TAVR. A retrospective analysis was made of consecutive TAVR patients from April 2008 to October 2014. Of patients who had pulmonary function testing and serum B-type natriuretic peptide data available before and after TAVR, 58 were found to have COPD (26 mild, 14 moderate, and 18 severe). Baseline variables and operative outcomes were explored along with changes in pulmonary function. Multiple regression analyses were performed to adjust for preoperative left ventricular ejection fraction and glomerular filtration rate. Comparison of pulmonary function testing before and after the procedure among all COPD categories showed a 10% improvement in forced vital capacity (95% confidence interval: 4% to 17%) and a 12% improvement in forced expiratory volume in 1 second (95% confidence interval: 6% to 19%). There was a 29% decrease in B-type natriuretic peptide after TAVR (95% confidence interval: -40% to -16%). An improvement of at least one COPD severity category was observed in 27% of patients with mild COPD, 64% of patients with moderate COPD, and 50% of patients with severe COPD. There was no 30-day mortality in any patient group. In patients with severe aortic stenosis, TAVR is associated with a significant improvement of pulmonary function and B-type natriuretic peptide. After TAVR, the reduction in COPD severity was most evident in patients with moderate and severe pulmonary dysfunction. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  16. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  18. Transcatheter Aortic Valve Implantation in Lower-Risk Patients With Aortic Stenosis: Is It Justified to Be the Preferred Treatment?

    Science.gov (United States)

    Abdelghani, Mohammad; Serruys, Patrick W

    2016-04-01

    Transcatheter aortic valve implantation underwent progressive improvements until it became the default therapy for inoperable patients, and a recommended therapy in high-risk operable patients with symptomatic severe aortic stenosis. In the lower-risk patient strata, a currently costly therapy that still has important complications with questionable durability is competing with the established effective and still-improving surgical replacement. This report tries to weigh the clinical evidence, the recent technical improvements, the durability, and the cost-effectiveness claims supporting the adoption of transcatheter aortic valve implantation in intermediate-low risk patients. The importance of appropriate patients' risk stratification and a more comprehensive approach to estimate that risk are also emphasized in the present report. © 2016 American Heart Association, Inc.

  19. Toll-Like Receptors, Inflammation, and Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Carmen García-Rodríguez

    2018-03-01

    Full Text Available Inflammation, the primary response of innate immunity, is essential to initiate the calcification process underlying calcific aortic valve disease (CAVD, the most prevalent valvulopathy in Western countries. The pathogenesis of CAVD is multifactorial and includes inflammation, hemodynamic factors, fibrosis, and active calcification. In the development of CAVD, both innate and adaptive immune responses are activated, and accumulating evidences show the central role of inflammation in the initiation and propagation phases of the disease, being the function of Toll-like receptors (TLR particularly relevant. These receptors act as sentinels of the innate immune system by recognizing pattern molecules from both pathogens and host-derived molecules released after tissue damage. TLR mediate inflammation via NF-κB routes within and beyond the immune system, and play a crucial role in the control of infection and the maintenance of tissue homeostasis. This review outlines the current notions about the association between TLR signaling and the ensuing development of inflammation and fibrocalcific remodeling in the pathogenesis of CAVD. Recent data provide new insights into the inflammatory and osteogenic responses underlying the disease and further support the hypothesis that inflammation plays a mechanistic role in the initiation and progression of CAVD. These findings make TLR signaling a potential target for therapeutic intervention in CAVD.

  20. Vortex dynamics in Patient-Specific Stenotic Tricuspid and Bicuspid Aortic Valves pre- and post- Trans-catheter Aortic Valve Replacement

    Science.gov (United States)

    Hatoum, Hoda; Dasi, Lakshmi Prasad

    2017-11-01

    Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.

  1. A giant myxoma originating from the aortic valve causing severe left ventricular tract obstruction: a case report and literature review.

    Science.gov (United States)

    Prifti, Edvin; Ademaj, Fadil; Kajo, Efrosina; Baboci, Arben

    2015-04-16

    The left ventricular localization of a myxoma is very rare, usually arising from the interventricular septum close to the left ventricular outflow tract, the mitral valve, the ventricular wall and extremely rarely the aortic valve. A 13-year-old male was admitted due to dyspnea and angina. Transesophageal echocardiography revealed left ventricular outflow tract obstruction with a mean gradient of 58 mmHg, and a mobile mass measuring 65×25 mm originating from the ventricular surface of the aortic valve was identified. The patient underwent urgent surgical excision and aortic valve replacement. Histopathological examination of the mass confirmed the diagnosis of a myxoma. In conclusion, a myxoma originating from the aortic valve remains a very rare localization. Total resection associated with aortic valve replacement seems to offer an excellent outcome.

  2. Transesophageal echocardiographic guidance of transcatheter closure of the aortic valve in a patient with left ventricular assist device-related severe aortic regurgitation

    Directory of Open Access Journals (Sweden)

    Preetham R Muskala

    2017-04-01

    Full Text Available A 68-year-old man with a severe ischemic cardiomyopathy underwent left ventricular assist device (LVAD implantation (Heart Mate II device for destination therapy. He presented 49 months after LVAD implantation with worsening heart failure symptoms and new severe aortic regurgitation. Given high risk for both surgical and transcatheter aortic valve replacement, he was admitted for transcatheter closure of the aortic valve under transesophageal echocardiographic (TEE guidance. TEE imaging revealed severe aortic regurgitation (Fig. 1A and B and Videos 1 and 2. Under TEE and fluoroscopic guidance, a 25 mm Amplatzer cribriform atrial septal defect closure device was advanced across the aortic valve (Fig. 1C and D and Videos 3 and 4. Immediately after device deployment, TEE revealed a well-seated device with complete aortic valve closure and trivial aortic regurgitation (Fig. 2A, B, C and D and Videos 5, 6, 7 and 8. Subsequent transthoracic echocardiograms obtained from 74 to 172 days after the procedure revealed no residual aortic regurgitation. The patient awoke with diffuse urticaria 244 days after the procedure and died en route to the emergency department, presumably secondary to a systemic allergic reaction. De novo aortic regurgitation is increasingly recognized in patients with LVADs (1. TEE-guided transcatheter aortic valve closure is an option in these high-risk patients (2.

  3. Reoperative aortic valve replacement in the octogenarians-minimally invasive technique in the era of transcatheter valve replacement

    NARCIS (Netherlands)

    Kaneko, Tsuyoshi; Loberman, Dan; Gosev, Igor; Rassam, Fadi; McGurk, Siobhan; Leacche, Marzia; Cohn, Lawrence

    2014-01-01

    Objective: Reoperative aortic valve replacement (re-AVR) in octogenarians is considered high risk and therefore might be indicated for transcatheter AVR. The minimally invasive technique for re-AVR limits dissection and might benefit this patient population. We report the outcomes of re-AVR in

  4. Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document

    NARCIS (Netherlands)

    A.P. Kappetein (Arie Pieter); S.J. Head (Stuart); P. Généreux (Philippe); N. Piazza (Nicolo); N.M. van Mieghem (Nicolas); E.H. Blackstone (Eugene); T.G. Brott (Thomas); D.J. Cohen (David J.); D.E. Cutlip (Donald); G.A. van Es (Gerrit Anne); R.T. Hahn (Rebecca); A.J. Kirtane (Ajay); M. Krucoff (Mitchell); S. Kodali (Susheel); M.J. Mack (Michael); R. Mehran (Roxana); J. Rodés-Cabau (Josep); P. Vranckx (Pascal); J.G. Webb (John); S.W. Windecker (Stephan); P.W.J.C. Serruys (Patrick); M.B. Leon (Martin)

    2012-01-01

    textabstractObjectives: The aim of the current Valvular Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI)- clinical endpoints to make them more suitable to the present and future needs of clinical trials.

  5. Replicating Patient-Specific Severe Aortic Valve Stenosis With Functional 3D Modeling.

    Science.gov (United States)

    Maragiannis, Dimitrios; Jackson, Matthew S; Igo, Stephen R; Schutt, Robert C; Connell, Patrick; Grande-Allen, Jane; Barker, Colin M; Chang, Su Min; Reardon, Michael J; Zoghbi, William A; Little, Stephen H

    2015-10-01

    3D stereolithographic printing can be used to convert high-resolution computed tomography images into life-size physical models. We sought to apply 3D printing technologies to develop patient-specific models of the anatomic and functional characteristics of severe aortic valve stenosis. Eight patient-specific models of severe aortic stenosis (6 tricuspid and 2 bicuspid) were created using dual-material fused 3D printing. Tissue types were identified and segmented from clinical computed tomography image data. A rigid material was used for printing calcific regions, and a rubber-like material was used for soft tissue structures of the outflow tract, aortic root, and noncalcified valve cusps. Each model was evaluated for its geometric valve orifice area, echocardiographic image quality, and aortic stenosis severity by Doppler and Gorlin methods under 7 different in vitro stroke volume conditions. Fused multimaterial 3D printed models replicated the focal calcific structures of aortic stenosis. Doppler-derived measures of peak and mean transvalvular gradient correlated well with reference standard pressure catheters across a range of flow conditions (r=0.988 and r=0.978 respectively, P3D printing, we demonstrate that patient-specific models can replicate both the anatomic and functional properties of severe degenerative aortic valve stenosis. © 2015 American Heart Association, Inc.

  6. Anesthetic management for percutaneous aortic valve implantation: an overview of worldwide experiences.

    Science.gov (United States)

    Ruggeri, L; Gerli, C; Franco, A; Barile, L; Magnano di San Lio, M S; Villari, N; Zangrillo, A

    2012-01-01

    Transcatheter aortic valve implantation is an emergent technique for high risk patients with aortic stenosis. Transcatheter aortic valve implantation poses significant challenges about its management, due to the procedure itself (i.e. the passage of large stiff sheaths in diseased vessels, the valve dilatation and the prosthesis positioning during a partial cardiac standstill) and the population of elder and high-risk patients who undergo the implantation. Retrograde transfemoral approach is the most popular procedure and a great number of cases is reported. Nevertheless, there is not a consensus regarding the intraoperative anesthesiological strategies, which vary in the different Centers. Sedation plus local anesthesia or general anesthesia are both valid alternatives and can be applied according to patient's characteristics and procedural instances. Most groups started the implantation program with a general anesthesia; indeed, it offers many advantages, mainly regarding the possibility of an early diagnosis and treatment of potential complications, through the use of the transesophageal echocardiography. However, after the initial experiences, many groups began to employ routinely sedation plus local anesthesia for transcatheter aortic valve implantation and their procedural and periprocedural success demonstrates that it is feasible, with many possible advantages. Many aspects about perioperative anesthetic management for transcatheter aortic valve implantation are still to be defined. Aim of this work is to clarify the different management strategies through a review of the available literature published in pubmed till June 2011.

  7. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.

    Science.gov (United States)

    Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron

    2016-01-01

    3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Transcatheter Aortic Valve Replacement: The Experience of One Brazilian Health Care Center

    Science.gov (United States)

    Azevedo, Fabiula Schwartz; Correa, Marcelo Goulart; Paula, Débora Holanda Gonçalves; Felix, Alex dos Santos; Belém, Luciano Herman Juaçaba; Mendes, Ana Paula Chedid; Silva, Valeria Gonçalves; Marques, Bruno Miranda; Monteiro, Andrey José de Oliveira; Weksler, Clara; Colafranceschi, Alexandre Siciliano; Kasal, Daniel Arthur Barata

    2018-01-01

    Objective Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period. Methods This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included. Results Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%). Conclusion Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.

  9. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    International Nuclear Information System (INIS)

    Fetterly, K; Mathew, V

    2014-01-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors

  10. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Mathew, V [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

  11. Where is the common sense in aortic valve replacement? A review of hemodynamics and sizing of stented tissue valves.

    Science.gov (United States)

    Doenst, Torsten; Amorim, Paulo A; Al-Alam, Nidal; Lehmann, Sven; Mukherjee, Chirojit; Faerber, Gloria

    2011-11-01

    Heated debates revolve around the hemodynamic performance of stented aortic tissue valves. Because the opening area strongly influences the generation of a pressure gradient over the prosthesis, and the outer diameter determines which valve actually fits into the aortic root, it would seem logical that the valve with the greatest opening area in relation to its outer diameter should allow the best hemodynamic performance. Interestingly, neither of these 2 parameters is reflected by the manufacturing companies' size labels or suggested sizing strategies. In addition, it is known that valves with the same size label from different companies may differ significantly in their actual dimension (outer diameter). Finally, the manufacturer-suggested sizing strategies differ so much that expected differences from valve design may get lost because of differences in sizing. These size and sizing differences and the lack of information on the geometric opening area complicate true hemodynamic comparisons significantly. Furthermore, some fluid dynamic considerations regarding the determination of opening area by echocardiography (the effective orifice area) introduce additional obscuring factors in the attempt to compare hemodynamic performance data of different stented tissue valves. We analyzed the true dimensions of different tissue prostheses and the manufacturer-suggested sizing strategies in relation to published effective orifice areas. We have demonstrated how sizing and implantation strategy have much greater impact on postoperative valve hemodynamics than valve brand or type. In addition, our findings may explain the different opinions regarding valve hemodynamics of different tissue valves. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. Anesthetic management for combined mitral valve replacement and aortic valve repair in a patient with osteogenesis imperfecta

    Directory of Open Access Journals (Sweden)

    Huang Jiapeng

    2011-01-01

    Full Text Available Osteogenesis imperfecta is a rare disorder of connective tissues and presents multiple challenges, including difficult airway, hyperthermia, coagulopathy and respiratory dysfunction, for anesthesiologists, especially during cardiac surgery. We present anesthetic management of a patient with osteogenesis impertecta during double valve surgery. Dexmedetomidine infusion minimized the risks of malignant hyperthermia. Glidescope and in-line stabilization facilitated endotracheal intubation and protected his oral structures and cervical spine. Transesophageal echocardiography (TEE diagnosed a flail A3 segment and redundant left coronary cusp causing mitral and aortic regurgitation. The mitral valve was replaced and the aortic valve repaired. Coagulopathy was corrected according to comprehensive coagulation analysis. Glidescope, dexmedetomidine, coagulation analysis and TEE could facilitate anesthetic management in these patients.

  13. Midterm evaluation of hemodynamics of the Top Hat supraannular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Nissen, Henrik; Geha, Alexander S

    2010-01-01

    measurements were compared in 38 patients with aortic valve stenosis. Hemodynamic data were comparable to those of other studies, but the Top Hat prosthesis implanted was significantly larger (by a mean of 3.29 mm) than the valve size indicated using an intraannular valve sizer in 48 patients. Mean effective...... studies of Top Hat or CarboMedics intraannular valves. Echocardiography was performed 6-48 months after surgery with Top Hat sizes 21-27. Parameters evaluated included mean gradient, peak gradient, effective orifice area, and effective orifice area index. Preoperative and postoperative echocardiographic...

  14. Aortic coarctation associated with aortic valve stenosis and mitral regurgitation in an adult patient: a two-stage approach using a large-diameter stent graft.

    Science.gov (United States)

    Novosel, Luka; Perkov, Dražen; Dobrota, Savko; Ćorić, Vedran; Štern Padovan, Ranka

    2014-02-01

    We report a case of a staged surgical and endovascular management in a 62-year-old woman with aortic coarctation associated with aortic valve stenosis and mitral regurgitation. The patient was admitted for severe aortic valve stenosis and mitral valve incompetence. During hospitalization and preoperative imaging, a previously undiagnosed aortic coarctation was discovered. The patient underwent a 2-stage approach that combined a Bentall procedure and mitral valve replacement in the first stage, followed by correction of the aortic coarctation by percutaneous placement of an Advanta V12 large-diameter stent graft (Atrium, Mijdrecht, The Netherlands) which to our knowledge has not been used in an adult patient with this combination of additional cardiac comorbidities. A staged approach combining surgical treatment first and endovascular placement of an Advanta V12 stent graft in the second stage can be effective and safe in adult patients with coarctation of the aorta and additional cardiac comorbidities. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Left Atrial Volume as Predictor of Valve Replacement and Cardiovascular Events in Patients with Asymptomatic Mild to Moderate Aortic Stenosis

    DEFF Research Database (Denmark)

    Dalsgaard, Morten; Egstrup, Kenneth; Wachtell, Kristian

    2013-01-01

    Left atrial (LA) size is known to increase with chronically increased left ventricular (LV) filling pressure. We hypothesized that LA volume was predictive of aortic valve replacement (AVR) and cardiovascular events in a large cohort of patients with asymptomatic mild to moderate aortic valve...

  16. The congenital bicuspid aortic valve with post-inflammatory disease--a neglected pathological diagnosis of clinical relevance

    NARCIS (Netherlands)

    Sadée, A. S.; Becker, A. E.; Verheul, J. A.

    1994-01-01

    It is unusual to find surgically excised congenital bicuspid aortic valves with post-inflammatory disease. We have analysed retrospectively all surgically excised aortic valves over a 6-year period for this particular diseased state in relation to relevant clinical data. There were 181 congenital

  17. Temporal changes of new-onset atrial fibrillation in patients randomized to surgical or transcatheter aortic valve replacement

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thyregod, Hans Gustav Hørsted; Tarp, Julie Bjerre

    2017-01-01

    BACKGROUND: Temporal development of new-onset atrial fibrillation (NOAF) after aortic valve replacement is unclear, and opportunistic screening has limited diagnostic accuracy. This is the first study to investigate the incidence and temporal development of NOAF detected by implantable loop...... recorder (ILR) in patients with aortic stenosis, randomized to surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHOD: An ILR was implanted in a subgroup of patients without pre-procedural atrial fibrillation (AF), randomized to SAVR or TAVR in the NOTION trial...

  18. Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study

    DEFF Research Database (Denmark)

    Haaverstad, Rune; Vitale, Nicola; Karevold, Asbjørn

    2006-01-01

    OBJECTIVE: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. METHODS: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received...... an aortic advantage valve prosthesis. Complete cumulative follow-up was 242.7 patient-years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. RESULTS: 30 day mortality was 2.4% (n = 4). Kaplan-Meier estimates of freedom from...... echocardiography. CONCLUSIONS: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use....

  19. Correction of moderate secondary mitral regurgitation due to aortic valve disease: immediate results

    Directory of Open Access Journals (Sweden)

    В. М. Назаров

    2015-10-01

    Full Text Available To evaluate the impact of surgical strategy in concomitant mitral valve surgery or isolated aortic valve replacement (AVR in patients with moderate secondary mitral regurgitation (MR, 1 574 patients underwent AVR over a period from January 2003 to December 2011. 241 patients had secondary MR 2+ and constituted the study population. Patients were stratified into two groups, those without concomitant mitral valve surgery (Group A, n = 113 and with it (Group B, n = 128. It was found out that AVR plastic correction of MI reduces its recurrence during short-term follow-up but increases the intervention time leading to an insignificant rise in lethality. In patients with aortic stenosis the age exceeding 70 years and the presence of atrial fibrillation are found to be the most significant predictors of preservation of residual mitral regurgitation in the early postoperative period, while more indicative for patients with aortic insufficiency is the presence of tricuspid regurgitation grade 2 or higher.

  20. Exercise Training in a Patient With a Left Ventricular Assist Device and Large Aortic Valve Thrombus.

    Science.gov (United States)

    Wuliya, Mijiti; Peyrot, Sandrine; Radu, Costin; Deux, Jean-François; Ben Elhaj, Habib; Lellouche, Nicolas; Damy, Thibaud; Guendouz, Soulef; Gellen, Barnabas

    2017-11-01

    An aortic valve thrombus (AVT) is a rare complication after HeartMate II implantation. In a 44-year-old man, a large AVT was discovered 6 weeks after implantation of a HeartMate II for severe dilated cardiomyopathy. The aortic valve was permanently closed. After a followup of 3 months without embolic events, the patient started a cardiac rehabilitation (CR) program involving aerobic exercise, resistance exercises, group gymnastics, and relaxation exercise, and completed the program without any complications, resulting in a significant functional benefit. CR might not be systematically contraindicated in patients with HeartMate II and an AVT, in particular, if there is no opening of the aortic valve at rest.

  1. An Engineering Analysis of the Aortic Valve Dynamics in Patients with Rotary Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    George Faragallah

    2013-01-01

    Full Text Available The use of a rotary Left Ventricular Assist Device (LVAD as a bridge-to-recovery treatment is gaining considerable attention in the LVAD research community. Using a mathematical model of the cardiovascular-LVAD system, this paper intends to define the critical control parameters in terms of power and rotational speed of the LVAD to ensure normal dynamics of the aortic valve for different levels of patient's activity and severity of heart failure. The effects of permanent closure of the aortic valve on the hemodynamics of the patient and the pump flow characteristics, if the critical control values are exceeded, are also examined. Additionally, LVAD power and speed control parameters that yield a given percentage of the cardiac cycle during which the aortic valve remains open are examined indicating that the severity of the heart failure is a very important factor in deciding the appropriateness of the LVAD as a bridge-to recovery treatment.

  2. CMR assessment after a transapical-transcatheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Biere, Loïc, E-mail: lobiere@chu-angers.fr [L’UNAM Université, Angers (France); Université d’Angers, Laboratoire Cardioprotection, Remodelage et Thrombose, CHU d’Angers, Service de Cardiologie, Angers (France); Pinaud, Frédéric [L’UNAM Université, Angers (France); Université d’Angers, CHU d’Angers, Service de Chirurgie Cardio-vasculaire et Thoracique, Angers (France); UMR-CNRS 6214, INSERM 1083, faculté de médecine, Angers (France); Delépine, Stéphane; Grall, Sylvain; Viot, Nathalie; Mateus, Victor; Rouleau, Frédéric [L’UNAM Université, Angers (France); Université d’Angers, Laboratoire Cardioprotection, Remodelage et Thrombose, CHU d’Angers, Service de Cardiologie, Angers (France); Corbeau, Jean-Jacques [Université d’Angers, CHU d’Angers, Département d’anesthésie-réanimation, Angers (France); Prunier, Fabrice [L’UNAM Université, Angers (France); Université d’Angers, Laboratoire Cardioprotection, Remodelage et Thrombose, CHU d’Angers, Service de Cardiologie, Angers (France); and others

    2014-02-15

    Aims: To describe the time course of myocardial scarring after transapical-transcatheter aortic valve implantation (TA-TAVI) with the Edwards SAPIEN XT™ and the Edwards SAPIEN™ prosthesis in a 3-month follow-up study using cardiac magnetic resonance imaging (CMR). Methods: In 20 TA-TAVI patients, CMR was performed at discharge and 3 months (3M). Cine-MRI was used for left ventricular (LV) functional assessment, and late gadolinium enhancement (LGE) imaging was employed for detecting the presence of myocardial scarring. Special attention was given to any artifacts caused by the prosthesis, which were consequently defined using a three-grade artifact scale. Results: We systematically reported the presence of small LGE hyperintensity relating to the apical segment, with no variation found between discharge and 3 M (2.8 ± 1.6 g vs. 2.35 ± 1.1 g). LV ejection fraction, end-diastolic, and end-systolic volumes did not significantly vary. A small area of apical akinesia was observed, with no improvement at follow-up. Whereas the Edwards SAPIEN XT™ prosthesis and the Edwards SAPIEN™ prosthesis are both constituted by metallic stenting structure, the Edwards SAPIEN™ was responsible for a larger signal void, thus potentially limiting the diagnostic performance of CMR. Conclusions: CMR may be performed safely in the context of TA-TAVI. The presence of a very small apical infarction correlating with focal akinesia was observed. As expected, the Edwards SAPIEN XT™ prosthesis was shown to be particularly suitable for CMR assessment.

  3. Alcohol consumption, cigarette smoking and incidence of aortic valve stenosis.

    Science.gov (United States)

    Larsson, S C; Wolk, A; Bäck, M

    2017-10-01

    Alcohol consumption and cigarette smoking are modifiable lifestyle factors with important impact on public health. It is unclear whether these factors influence the risk of aortic valve stenosis (AVS). To investigate the associations of alcohol consumption and smoking, including smoking intensity and time since cessation, with AVS incidence in two prospective cohorts. This analysis was based on data from the Swedish Mammography Cohort and the Cohort of Swedish Men, comprising 69 365 adults without cardiovascular disease at baseline. Participants were followed for AVS incidence and death by linkage to the Swedish National Patient and Causes of Death Registers. Hazard ratios (HR) with 95% confidence intervals (CI) were estimated by Cox proportional hazards regression. Over a mean follow-up of 15.3 years, 1249 cases of AVS (494 in women and 755 in men) were recorded. Compared with never drinkers of alcohol (lifelong abstainers), the risk of AVS was significantly lower in current light drinkers (1-6 drinks per week [1 drink = 12 g alcohol]; multivariable HR 0.82; 95% CI: 0.68-0.99). The risk of AVS increased with increasing smoking intensity. Compared with never smokers, the HR was 1.46 (95% CI: 1.16-1.85) in current smokers of ≥30 pack-years. Former smokers who had quit smoking 10 or more years previously had similar risk for AVS as never smokers. This study suggests that current light alcohol consumption is associated with a lower risk of AVS, and indicates that the association between smoking and AVS risk is reversible. © 2017 The Authors. Journal of Internal Medicine published by John Wiley & Sons Ltd on behalf of Association for Publication of The Journal of Internal Medicine.

  4. Determination of oxidation state of iron in normal and pathologically altered human aortic valves

    Energy Technology Data Exchange (ETDEWEB)

    Czapla-Masztafiak, J. [Institute of Nuclear Physics PAN, Radzikowskiego 152, 31-342 Kraków (Poland); Lis, G.J.; Gajda, M.; Jasek, E. [Department of Histology, Jagiellonian University Medical College, Kopernika 7, 31-034 Kraków (Poland); Czubek, U. [Department of Coronary Disease, Jagiellonian University Medical College, John Paul II Hospital, Prądnicka 80, 31-202 Kraków (Poland); Bolechała, F. [Department of Forensic Medicine, Jagiellonian University Medical College, Grzegórzecka 16, 31-531 Kraków (Poland); Borca, C. [Swiss Light Source, Paul Scherrer Institute, 5232 Villigen PSI (Switzerland); Kwiatek, W.M. [Institute of Nuclear Physics PAN, Radzikowskiego 152, 31-342 Kraków (Poland)

    2015-12-01

    In order to investigate changes in chemical state of iron in normal and pathologically altered human aortic valves X-ray absorption spectroscopy was applied. Since Fe is suspected to play detrimental role in aortic valve stenosis pathogenesis the oxidation state of this element has been determined. The experimental material consisted of 10 μm sections of valves excised during routine surgery and from autopsies. The experiment was performed at the MicroXAS beamline of the SLS synchrotron facility in Villigen (Switzerland). The Fe K-edge XANES spectra obtained from tissue samples were carefully analyzed and compared with the spectra of reference compounds containing iron in various chemical structures. The analysis of absorption edge position and shape of the spectra revealed that both chemical forms of iron are presented in valve tissue but Fe{sup 3+} is the predominant form. Small shift of the absorption edge toward higher energy in the spectra from stenotic valve samples indicates higher content of the Fe{sup 3+} form in pathological tissue. Such a phenomenon suggests the role of Fenton reaction and reactive oxygen species in the etiology of aortic valve stenosis. The comparison of pre-edge regions of XANES spectra for control and stenotic valve tissue confirmed no differences in local symmetry or spin state of iron in analyzed samples.

  5. Initial non-opioid based anesthesia in a parturient having severe aortic stenosis undergoing cesarean section with aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Subrata Podder

    2015-01-01

    Full Text Available Pregnancy in presence of severe aortic stenosis (AS causes worsening of symptoms needing further intervention. In the advanced stages of pregnancy, some patients may even require aortic valve replacement (AVR and cesarean delivery in the same sitting. Opioid based general anesthesia for combined lower segment cesarean section (LSCS with AVR has been described. However, the use of opioid may lead to fetal morbidity and need of respiratory support for the baby. We describe successful anesthetic management for LSCS with AVR in a >33 week gravida with severe AS and congestive heart failure. We avoided opioids till delivery of the baby AVR; the delivered neonate showed a normal APGAR score.

  6. Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

    Directory of Open Access Journals (Sweden)

    Luis M Astudillo

    2012-01-01

    Full Text Available OBJECTIVE: We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD: We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm²/m, 0.85-0.66 cm²/m², and <0.65 cm²/m², respectively. RESULTS: A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%. In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. CONCLUSION: Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical

  7. Valve-sparing aortic root reconstruction in children, teenagers, and young adults.

    Science.gov (United States)

    Tweddell, James S; Earing, Michael G; Bartz, Peter J; Dunham-Ingles, Jennifer L; Woods, Ronald K; Mitchell, Michael E

    2012-08-01

    We reviewed our experience with valve-sparing aortic root reconstruction (VSARR) using the sinus of Valsalva graft in children, teenagers, and young adults with connective tissue disorders. Results of a single-center experience with VSARR in children, teenagers, and young adults were retrospectively analyzed. End points were death, freedom from reintervention, and freedom from valve dysfunction. Between 2003 and 2010, 16 patients (Marfan, 9; Loeys Dietz syndrome, 6; conotruncal, 1) underwent VSARR. The mean age was 20±7.4 (range, 9 to 36 years). Indications for VSAAR were aortic root enlargement in 14 (sinus of Valsalva Z-score, 6.2±2) and aortic dissection in 2. Additional procedures included replacement of the ascending aorta in 7, with additional replacement of the aortic arch in 2. No early or late deaths occurred. One patient required a pacemaker. One patient with Loeys-Dietz syndrome required reoperation for aneurysmal dilatation of the coronary buttons. Two patients underwent replacement of the thoracoabdominal aorta for chronic dissection. Follow-up by echocardiography or magnetic resonance imaging at a mean of 33±29 months showed more than mild aortic regurgitation in 2 patients. Both patients with moderate aortic insufficiency also had a bicuspid aortic valve. VSARR using the sinus of Valsalva graft is a reproducible technique that achieves acceptable early and intermediate results. It is suitable for children, teenagers, and young adults. Anticoagulation is avoided. The procedure is appropriate for emergency operations but should be used with caution in patients with a bicuspid aortic valve. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Aortic valve replacement with simultaneous chest wall reconstruction for radiation-induced sarcoma.

    Science.gov (United States)

    Sachithanandan, Anand; Dandekar, Uday; Grimer, Robert; Peart, Francis; Rooney, Stephen J

    2008-01-01

    Sarcomas, a rare complication of radiotherapy for breast carcinoma, have a poor prognosis. We describe a lady with previous mantle radiotherapy exposure, who developed a radiation-induced chest wall sarcoma. She underwent simultaneous aortic valve replacement (AVR) for severe aortic stenosis and excision of the sarcoma. Chest wall reconstruction was achieved with a composite marlex cement plate and a pedicled latissimus dorsi muscle flap.

  9. Lipoprotein(a-Associated Molecules Are Prominent Components in Plasma and Valve Leaflets in Calcific Aortic Valve Stenosis

    Directory of Open Access Journals (Sweden)

    Michael Torzewski, MD

    2017-06-01

    Full Text Available Summary: The LPA gene is the only monogenetic risk factor for calcific aortic valve stenosis (CAVS. Oxidized phospholipids (OxPL and lysophosphatidic acid generated by autotaxin (ATX from OxPL are pro-inflammatory. Aortic valve leaflets categorized pathologically from both ATX–apolipoprotein B and ATX–apolipoprotein(a were measureable in plasma. Lipoprotein(a (Lp[a], ATX, OxPL, and malondialdehyde epitopes progressively increased in immunostaining (p < 0.001 for all. Six species of OxPL and lysophosphatidic acid were identified after extraction from valve leaflets. The presence of a constellation of pathologically linked, Lp(a-associated molecules in plasma and in aortic valve leaflets of patients with CAVS suggest that Lp(a is a key etiologic factor in CAVS. Key Words: aortic valve stenosis, autotaxin, inflammation, Lp(a, oxidation-specific epitopes

  10. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease.

    Science.gov (United States)

    van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (preport a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Dynamic Three-Dimensional Geometry of the Aortic Valve Apparatus-A Feasibility Study.

    Science.gov (United States)

    Khamooshian, Arash; Amador, Yannis; Hai, Ting; Jeganathan, Jelliffe; Saraf, Maria; Mahmood, Eitezaz; Matyal, Robina; Khabbaz, Kamal R; Mariani, Massimo; Mahmood, Feroze

    2017-08-01

    To provide (1) an overview of the aortic valve (AV) apparatus anatomy and nomenclature, and (2) data regarding the normal AV apparatus geometry and dynamism during the cardiac cycle obtained from three-dimensional transesophageal echocardiography (3D TEE). Retrospective feasibility study. A single-center university teaching hospital. The study was performed on data of 10 patients with a nonregurgitant, nonstenotic aortic valve undergoing cardiac surgery. Intraoperative 3D TEE was performed on all the participants using the Siemens ACUSON SC2000 ultrasound system and Z6Ms transducer (Siemens Medical Systems, Mountainview, CA). Dynamic offline analyses were performed with Siemens eSie valve analytical software in a semiautomated fashion. Forty-five parameters were exported of which 13 were selected and analyzed. The cardiac cycle was divided into 4 quartiles to account for frame-rate variations. The annulus, sinus of Valsalva (SoV) and sinotubular junction (STJ) areas, diameter, perimeter and height, aortic leaflet height, leaflet coaptation height, and aortic valve-mitral valve angle changed significantly during the cardiac cycle (p < 0.001). STJ expanded more than both the annulus and the SoV (p < 0.001). The maximum aortic valve leaflet height change was greater in the left and right versus noncoronary leaflet (p < 0.001). The semiautomated AV apparatus dynamic assessment using eSie valve software is a clinically feasible technique and can be performed readily in the operating room. It has the potential to significantly impact intraoperative decision-making in cases suitable for AV repair. The AV apparatus is a dynamic structure and demonstrates significant changes during the cardiac cycle. Copyright © 2017. Published by Elsevier Inc.

  12. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Transcatheter aortic valve implantation under conscious sedation - the first Indian experience.

    Science.gov (United States)

    Maqbool, Syed; Kumar, Vijay; Rastogi, Vishal; Seth, Ashok

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) is maturing strongly as an alternative to surgical aortic valve replacement (SAVR) in patients who are inoperable/high risk for open heart surgery. General anesthesia (GA) is the usual mode of anesthesia in these patients, but local anesthesia with conscious sedation (LACS) has recently been described as a safe alternative with some added advantages. We report 2 cases who were unfit for GA and were done successfully under LACS. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  14. Concomitant aortic valve and internal mammary artery injuries in blunt chest trauma: report of a case.

    Science.gov (United States)

    Yeh, Chun-Chieh; Hsieh, Chi-Hsun; Wang, Yu-Chun; Chung, Ping-Kuei; Chen, Ray-Jade

    2009-01-01

    We report a case of concomitant injury to the aortic valve and internal mammary artery (IMA) from nonpenetrating chest trauma. To our knowledge, this is the first such case to be reported. Transcatheter arterial embolization (TAE) following diagnostic angiography offers an effective and minimally invasive treatment for traumatic IMA injuries. Because there might be an asymptomatic interval after traumatic aortic valve injuries, serial physical examinations and repeated echocardiography should be mandatory for patients with de novo heart failure after blunt chest trauma. Transesophageal echocardiography can provide a clearer image of cardiac injuries than transthoracic echocardiography, particularly if there is extensive anterior mediastinal hematoma resulting from IMA trauma.

  15. Sutureless aortic valve replacement using a novel autologous tissue heart valve with stent (stent biovalve): proof of concept.

    Science.gov (United States)

    Kishimoto, Satoru; Takewa, Yoshiaki; Nakayama, Yasuhide; Date, Kazuma; Sumikura, Hirohito; Moriwaki, Takeshi; Nishimura, Motonobu; Tatsumi, Eisuke

    2015-06-01

    We developed an autologous, trileaflet tissue valve ("biovalve") using in-body tissue architecture technology to overcome the disadvantages of current bioprosthetic valves. We designed a novel biovalve with a balloon-expandable stent: the stent biovalve (SBV). This study evaluated the technical feasibility of sutureless aortic valve replacement using the SBV in an orthotopic position, as well as the functionality of the SBV under systemic circulation, in an acute experimental goat model. Three adult goats (54.5-56.1 kg) underwent sutureless AVR under cardiopulmonary bypass (CPB). The technical feasibility and functionality of the SBVs were assessed using angiography, pressure catheterization, and two-dimensional echocardiography. The sutureless AVR was successful in all goats, and all animals could be weaned off CPB. The mean aortic cross-clamp time was 45 min. Angiogram, after weaning the animals off CPB, showed less than mild paravalvular leakage and central leakage was not detected in any of the goats. The mean peak-to-peak pressure gradient was 6.3 ± 5.0 mmHg. Epicardial two-dimensional echocardiograms showed smooth leaflet movement, including adequate closed positions with good coaptation; the open position demonstrated a large orifice area (average aortic valve area 2.4 ± 0.1 cm2). Sutureless AVR, using SBVs, was feasible in a goat model. The early valvular functionalities of the SBV were sufficient; future long-term experiments are needed to evaluate its durability and histological regeneration potential.

  16. Aortic Valve Myxoma in a Young Man: A Case Report and Review of Literature.

    Science.gov (United States)

    Ji, Zhenchun; Wang, Longgang; Sun, Jiacheng; Ye, Wenxue; Yu, Yunsheng; Huang, Haoyue; Hu, Yanqiu; Yang, Ziying; Shen, Zhenya

    2017-04-30

    Myxoma is the most commonly found cardiac primary tumor. The left atrium is the most common localization of myxoma, followed by the right atrium. However, it is rare in the left and right ventricles. Myxoma originating from cardiac valves is extremely rare. This article presents a case of a 17-year-old male who was admitted due to heart murmur for one year. Transthoracic echocardiography indicated a 1.9 cm round solid mass in the left ventricular outflow tract. Excision surgery and aortic valve replacement were performed in this patient. Histopathology revealed the mass as a myxoma. The aortic valve remains a very rare myxoma localization position. Echocardiography can provide a precise method for myxoma diagnosis. Early excision associated with valve replacement can provide good curative effects.

  17. Non-linear rotation-free shell finite-element models for aortic heart valves.

    Science.gov (United States)

    Gilmanov, Anvar; Stolarski, Henryk; Sotiropoulos, Fotis

    2017-01-04

    Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY) material models have been considered and compared. Uniaxial tests for those constitutive equations were performed to verify the formulation and implementation of the models. The issue of leaflets interactions during the closing of the heart valve at the end of systole is considered. The critical role of using non-linear anisotropic model for proper dynamic response of the heart valve especially during the closing phase is demonstrated quantitatively. This work contributes an efficient FE framework for simulating biological tissues and paves the way for high-fidelity flow structure interaction simulations of native and bioprosthetic aortic heart valves. Copyright © 2016. Published by Elsevier Ltd.

  18. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  19. Interaction of renal failure and dyslipidaemia in the development of calcific aortic valve disease in rats.

    Science.gov (United States)

    Gillis, Kris; Roosens, Bram; Bala, Gezim; Remory, Isabel; Hernot, Sophie; Delvenne, Philippe; Mestrez, Fabienne; Droogmans, Steven; Cosyns, Bernard

    2017-10-01

    Calcific aortic valve disease (CAVD) is currently the most common heart valve disease worldwide and is known to be an active process. Both renal failure and dyslipidaemia are considered to be promoting factors for the development of valvular calcifications. The aim of this study is to prospectively evaluate the respective contribution and interaction of renal failure and dyslipidaemia on CAVD in a rat model, using echocardiography and compared with histology. Sixty-eight male Wistar rats were prospectively divided in eight groups, each fed a different diet to induce renal failure alone and combined with hyperlipidaemia or hypercholesterolemia. CAVD was detected and quantified by calibrated integrated backscatter of ultrasound (cIB) and compared with the histological calcium score. The study follow-up was 20 weeks. At the end of the study, the cIB value and the calcium score of the aortic valve were significantly increased in the group with isolated renal failure but not with dyslipidaemia. The combination of renal failure with high cholesterol or high-fat diet did not significantly increase calcifications further. Renal failure alone does induce aortic valve calcifications in a rat model of CAVD, whereas dyslipidaemia alone does not. The combination of renal failure with dyslipidaemia does not increase calcification further. These findings suggest that a combination of atherosclerotic and calcifying factors is not required to induce aortic valve calcifications in this model.

  20. Metastatic Calcinosis of Aortic Valve Secondary to Renal Failure Mimicking Infective Endocarditis

    Directory of Open Access Journals (Sweden)

    Noman Ahmed Jang Khan

    2016-01-01

    Full Text Available End stage renal disease has a list of consequences, cardiovascular being the most common. Inefficient dialysis can cause significant deposition of calcium all over the body, including heart valves making heart function impaired. We illustrate a case of 38-year-old female with end stage renal disease on peritoneal dialysis. The patient had been complaining of pain and swelling of the right hand for the last few months and had been seen by hand surgeon and was admitted electively for the biopsy of hand lesions. Before her planned surgery, she developed severe shortness of breath. Urgent echocardiogram revealed severe aortic regurgitation and large vegetation on the aortic valve. Infective endocarditis was suspected but blood cultures were negative for any microorganism and the patient did not meet the Duke criteria. Because of her hemodynamic instability immediate mechanical valve replacement surgery was performed. The pathology report showed extensive calcification and myxoid degeneration. No infectious agent was found. Later on, biopsy of her hand lesions showed extensive calcification with macrophages and giant cells. No atypia or malignancy was identified. This is a rare case of the metastatic calcinosis of aortic valve secondary to renal failure mimicking aortic valve infective endocarditis.

  1. 4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo

    Science.gov (United States)

    Schnabel, Christian; Jannasch, Anett; Faak, Saskia; Waldow, Thomas; Koch, Edmund

    2015-07-01

    The heart and its mechanical components, especially the heart valves and leaflets, are under enormous strain during lifetime. Like all highly stressed materials, also these biological components undergo fatigue and signs of wear, which impinge upon cardiac output and in the end on health and living comfort of affected patients. Thereby pathophysiological changes of the aortic valve leading to calcific aortic valve stenosis (AVS) as most frequent heart valve disease in humans are of particular interest. The knowledge about changes of the dynamic behavior during the course of this disease and the possibility of early stage diagnosis could lead to the development of new treatment strategies and drug-based options of prevention or therapy. ApoE-/- mice as established model of AVS versus wildtype mice were introduced in an ex vivo artificially stimulated heart model. 4D optical coherence tomography (OCT) in combination with high-speed video microscopy were applied to characterize dynamic behavior of the murine aortic valve and to characterize dynamic properties during artificial stimulation. OCT and high-speed video microscopy with high spatial and temporal resolution represent promising tools for the investigation of dynamic behavior and their changes in calcific aortic stenosis disease models in mice.

  2. Orthotopic replacement of aortic heart valves with tissue-engineered grafts.

    Science.gov (United States)

    Tudorache, Igor; Calistru, Alex; Baraki, Hassina; Meyer, Tanja; Höffler, Klaus; Sarikouch, Samir; Bara, Christopher; Görler, Adelheid; Hartung, Dagmar; Hilfiker, Andres; Haverich, Axel; Cebotari, Serghei

    2013-08-01

    Heart valve tissue engineering aims to create a graft with improved durability compared to routinely used valve substitutes. This study presents the function and morphological changes of a tissue-engineered aortic valve (TEV) compared to the cryopreserved valve (CPV), aortic valve (AV) allografts in an orthotopic position in sheep. Ovine AV conduits (n=5) were decellularized with detergents. Autologous endothelial cells (ECs) were seeded onto the valve surface and cultured under physiological conditions using a high pulsatile flow. Grafts were implanted as a root with reimplantation of coronary ostia in sheep. Crystalloid cardioplegia and isogenic blood transfusions from previous sacrificed sheep were used. Only antiplatelet aggregation therapy was used postoperatively. CPVs (n=4) served as controls. The grafts were investigated for function (echocardiography, magnetic resonance investigation), morpho/histological appearance, graft rejection, and calcification at 3 months. Decellularization led to cell-free scaffolds with preserved extracellular matrices, including the basement membrane. TEVs were covered with ECs expressing typical endothelial markers. Neither dilatation, stenosis, reductions of cusp mobility nor a significant transvalvular gradient, were observed in the TEV group. Explanted valves exhibited normal morphology without signs of inflammation. An endothelial monolayer covered cusps and the valve sinus. In the CPV group, sporadic, macroscopic, calcified degeneration with mild AV insufficiency was noted. Histology revealed signs of rejection and incipient calcification of the tissue. Tissue-engineered AV based on decellularized valve allografts satisfy short-term requirements of the systemic circulation in sheep. Although results of long-term experiments are pending, the lack of degenerative traits thus far, makes these grafts a promising alternative for future aortic heart valve surgery.

  3. Intermittent intravalvar regurgitation of a mechanical aortic valve ...

    African Journals Online (AJOL)

    Mechanical prosthetic valve regurgitation may be either periprosthetic or intraprosthetic. The later is usually mild, occurring in the majority of normally functioning valves and is due to the 'regurgitant flow' closing the valve. An unusual case is reported of intermitent intraprosthetic regurgitation through a normally functioning ...

  4. Learning Alternative Access Approaches for Transcatheter Aortic Valve Replacement: Implications for New Transcatheter Aortic Valve Replacement Centers.

    Science.gov (United States)

    Henn, Matthew C; Percival, Thomas; Zajarias, Alan; Melby, Spencer J; Lindman, Brian R; Quader, Nishath; Damiano, Ralph J; Moon, Marc R; Lasala, John M; Rao, Ravinder S; Bell, Jennifer; Damiano, Marci S; Maniar, Hersh S

    2017-05-01

    Smaller transcatheter aortic valve replacement (TAVR) delivery systems have increased the number of patients eligible for transfemoral procedures while decreasing the need for transaortic (TAo) or transapical (TA) access. As a result, newer TAVR centers are likely to have less exposure to these alternative access techniques, making it harder to achieve proficiency. The purpose of this study was to evaluate the learning curve for TAVR approaches and compare perioperative outcomes. From January 2008 to December 2014, 400 patients underwent TAVR (transfemoral, n = 179; TA, n = 120; and TAo, n = 101)). Learning curves were constructed using metrics of contrast utilization, procedural, and fluoroscopy times. Outcomes during the learning curve were compared with after proficiency was achieved. Depending on the metric, learning curves for all three routes differed slightly but all demonstrated proficiency by the 50th case. There were no significant differences in procedural times whereas improvements in contrast use were most notable for TA (69 ± 40 mL versus 50 ± 23 mL, p = 0.002). For both TA and TAo, fewer patients received transfusions once proficiency was reached (62% versus 34%, p = 0.003, and 42% versus 14%, p = 0.002, respectively). No differences in 30-day or 1-year mortality were seen before or after proficiency was reached for any approach. The learning curves for TA and TAo are distinct but technical proficiency begins to develop by 25 cases and becomes complete by 50 cases for both approaches. Given the relatively low volume of alternative access, achieving technical proficiency may take significant time. However, technical proficiency had no effect on 30-day or 1-year mortality for any access approach. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Left ventricular diastolic function is associated with symptom status in severe aortic valve stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Christensen, Nicolaj L; Videbæk, Lars

    2014-01-01

    BACKGROUND: In aortic valve stenosis (AS), the occurrence of heart failure symptoms does not always correlate with severity of valve stenosis and left ventricular (LV) function. Therefore, we tested the hypothesis that symptomatic patients with AS have impaired diastolic, longitudinal systolic...... atrial volume index, and deceleration time were still associated with the presence of symptoms. CONCLUSIONS: The present study demonstrates that symptomatic status in severe AS is associated with impaired diastolic function, LV hypertrophy, concentric remodeling, and left atrial dilatation when corrected...

  6. Association between aortic valve calcification measured on non-contrast computed tomography and aortic valve stenosis in the general population

    DEFF Research Database (Denmark)

    Paulsen, Niels Herluf; Bønløkke Carlsen, Bjarke; Dahl, Jordi Sanchez

    2016-01-01

    BACKGROUND: Aortic valve calcification (AVC) measured on non-contrast computed tomography (CT) has shown correlation to severity of aortic valve stenosis (AS) and mortality in patients with known AS. The aim of this study was to determine the association of CT verified AVC and subclinical...... AS in a general population undergoing CT. METHODS: CT scans from 566 randomly selected male participants (age 65-74) in the Danish cardiovascular screening study (DANCAVAS) were analyzed for AVC. All participants with a moderately or severely increased AVC score (≥300 arbitrary units (AU)) and a matched control...... ICD leads 16 individuals were excluded from the AVC scoring. Moderate or severe increased AVC was observed in 10.7% (95% CI: 8.4-13.7). Echocardiography was performed in 101 individuals; 32.7% (95% CI: 21.8 to 46.0) with moderate or high AVC score had moderate or severe AS, while none with no or low...

  7. Echocardiographic evaluation of cardiac function response to removal of aortic stenosis: Surgical and trans-catheter aortic valve implantation (TAVI

    Directory of Open Access Journals (Sweden)

    Ying Zhao

    2013-01-01

    Full Text Available Aortic stenosis (AS is the commonest valve disease in the West, with a prevalence varying between 0.02% in adults under 44 years and 3-9% in those over 80 years of age 1, 2. The disease may remain “silent” and hence unnoticed for years, particularly in the elderly with naturally limited exercise. With the development of symptoms, patients may carry a mortality of 36-52%, 52-80% and 80-90% at 3, 5 and 10 years, respectively if left untreated, with a potential high risk of sudden death 3. Surgical aortic valve replacement (SAVR used to be the only effective treatment for severe AS, being the second indication for open heart surgery after coronary artery bypass grafting (CABG 4. Trans-catheter aortic valve implantation (TAVI is a recently developed procedure which aims at non-surgical AVR in patients with severe, symptomatic and calcified AS who are at high surgical risk because of either poor left ventricular (LV function, ejection fraction (EF 80 years, previous CABG surgery and/ or aorta or other heart valve surgery, impaired kidney function, chronic obstructive pulmonary disease (COPD or pulmonary hypertension 5. Currently, this technique is not recommended in bicuspid AS patients due to the risk of incomplete and suboptimal deployment of the aortic prosthesis [6]. TAVI avoids open heart surgery and hence is likely to protect myocardial function. The purpose of this paper is to review the echocardiographic evaluation of LV, right ventricular (RV, and left atrial (LA function response to SAVR and TAVI for AS.

  8. Aortic valve replacement with 17-mm St. Jude Medical prostheses for a small aortic root in elderly patients.

    Science.gov (United States)

    Takaseya, Tohru; Kawara, Takemi; Tokunaga, Shigehiko; Kohno, Michitaka; Oishi, Yasuhisa; Morita, Shigeki

    2007-06-01

    There are few reports about the optimal prosthesis for elderly patients who have small aortic roots with an aortic annular size of less than 19 mm. From October 2004 to October 2006, 11 women aged 70 years or older (mean age, 74.9 +/- 3.5 years) underwent aortic valve replacement with a 17-mm Regent prosthesis (St. Jude Medical, St. Paul, MN), with the size determined using the manufacturer's sizer. Clinical status and the results of preoperative and postoperative echocardiography were evaluated. The patients had a mean body surface area of 1.33 +/- 0.13 m2. Preoperative average New York Heart Association (NYHA) functional class was 2.5 +/- 0.7. Preoperative echocardiography showed a mean indexed effective orifice area of 0.33 +/- 0.14 cm2/m2 and a left ventricular mass index of 175 +/- 63 g/m2. Seven patients underwent associated procedures. Postoperative ventilation time was 14 +/- 5.6 hours, and the intensive care unit stay was 1.0 +/- 0.4 days. No patients died perioperatively. The NYHA functional class improved to class I in 9 patients. No obstruction of valve opening was observed. A significant increase in the mean indexed effective orifice area (0.87 +/- 0.10 cm2/m2) and regression of left ventricular mass index were found (114 +/- 46 cm2/m2) on postoperative echocardiography. Aortic valve replacement in elderly patients with small aortic roots (less than 19 mm) using a 17-mm Regent prosthesis showed satisfactory clinical and hemodynamic results.

  9. Valve-sparing root replacement in children with aortic root aneurysm: mid-term results.

    Science.gov (United States)

    Lange, Rüdiger; Badiu, Catalin C; Vogt, Manfred; Voss, Bernhard; Hörer, Jürgen; Prodan, Zsolt; Schreiber, Christian; Mazzitelli, Domenico

    2013-05-01

    We aimed at evaluating the results of aortic valve-sparing root replacement (AVSRR) in children with aortic root aneurysm (ARA) due to genetic disorders in terms of mortality, reoperation and recurrent aortic valve regurgitation (AVR). Thirteen patients (mean age 9.7 ± 6.5 years, 10 months-18 years) underwent AVSRR for ARA between 2002 and 2011. Six of the 13 patients had Marfan syndrome, 3 Loeys-Dietz syndrome (LDS), 2 bicuspid aortic valve syndrome and 2 an unspecified connective tissue disorder. AVR was graded as none/trace, mild and severe in 5, 7 and 1 patient, respectively. The mean pre-operative root diameter was 45 ± 10 mm (mean Z-score 10.3 ± 2.0). Remodelling of the aortic root was performed in 4 patients, reimplantation of the aortic valve in 9 and a concomitant cusp repair in 4. The diameter of the prostheses used for root replacement varied from 22 to 30 mm (mean Z-score = 2.3 ± 3). The follow-up was 100% complete with a mean follow-up time of 3.7 years. There was no operative mortality. One patient with LDS died 2.5 years after the operation due to spontaneous rupture of the descending aorta. Root re-replacement with mechanical conduit was necessary in 1 patient for severe recurrent AVR 8 days after remodelling of the aortic root. At final follow-up, AVR was graded as none/trace and mild in all patients. Eleven patients presented in New York Heart Association functional Class I and 1 in Class II. In paediatric patients with ARA, valve-sparing root replacement can be performed with low operative risk and excellent mid-term valve durability. Hence, prosthetic valve-related morbidity may be avoided. Due to the large diameters of the aortic root and the ascending aorta, the size of the implanted root prostheses will not limit later growth of the native aorta.

  10. Blood flow competition after aortic valve bypass: an evaluation using computational fluid dynamics.

    Science.gov (United States)

    Kawahito, Koji; Kimura, Naoyuki; Komiya, Kenji; Nakamura, Masanori; Misawa, Yoshio

    2017-05-01

    Aortic valve bypass (AVB) (apico-aortic conduit) remains an effective surgical alternative for patients in whom surgical aortic valve replacement or transcatheter aortic valve implantation is not feasible. However, specific complications include thrombus formation, possibly caused by stagnation arising from flow competition between the antegrade and retrograde flow, but this has not been fully investigated. The aim of this study was to analyse flow characteristics after AVB and to elucidate mechanisms of intra-aortic thrombus using computational fluid dynamics (CFD). Flow simulation was performed on data obtained from a 73-year-old postoperative AVB patient. Three-dimensional cine phase-contrast magnetic resonance imaging at 3 Tesla was used to acquire flow data and to set up the simulation. The vascular geometry was reconstructed using computed tomography angiograms. Flow simulations were implemented at various ratios of the flow rate between the ascending aorta and the graft. Results were visualized by streamline and particle tracing. CFD demonstrated stagnation in the ascending aorta-arch when retrograde flow was dominant, indicating that the risk of thrombus formation exists in the ascending arch in cases with severe aortic stenosis and/or poor left ventricular function. Meanwhile, stagnation was observed in the proximal descending aorta when the antegrade and retrograde flow were equivalent, suggesting that the descending aorta is critical when aortic stenosis is not severe. Flow stagnation in the aorta which may cause thrombus was observed when retrograde flow was dominant and antegrade/retrograde flows were equivalent. Our results suggest that anticoagulants might be recommended even in patients who receive biological valves. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis.

    Science.gov (United States)

    Angeloni, Emiliano; Melina, Giovanni; Pibarot, Philippe; Benedetto, Umberto; Refice, Simone; Ciavarella, Giuseppino M; Roscitano, Antonino; Sinatra, Riccardo; Pepper, John R

    2012-01-01

    Secondary mitral regurgitation (SMR) is generally reduced after isolated aortic valve replacement (AVR), but there is important interindividual variability in the magnitude of this reduction. Prosthesis-patient mismatch (PPM) may hinder normalization of left ventricular geometry and pressure overload following AVR, therefore we aimed to investigate the relationship between PPM and regression of SMR following AVR for aortic valve stenosis. A total of 419 patients with AS who underwent isolated AVR at 2 institutions and presenting moderate SMR (mitral regurgitant volume 30 to 45 mL/beat) not considered for surgical correction were included in this study. Clinical and echocardiographic follow-up were completed at a median follow-up time of 37 months. PPM was defined as an indexed effective orifice area ≤0.85 cm(2)/m(2) and was found in 170/419 patients (40.6%). There were no significant differences in baseline and operative characteristics between patients with or without PPM. Patients with PPM had less regression of SMR following AVR compared with those with no PPM (change in mitral regurgitant volume: -11±4 versus -17±5 mL, respectively; Pregression model, which showed indexed effective orifice area (Pregression of SMR following AVR. This unfavorable effect was associated with worse functional capacity. These findings emphasize the importance of operative strategies aiming to prevent PPM in patients with aortic valve stenosis and concomitant SMR.

  12. Use of an Automated Suture Fastening Device in Minimally Invasive Aortic Valve Replacement.

    Science.gov (United States)

    Beute, Tyler J; Orem, Matthew D; Schiller, Timothy M; Goehler, Matthew; Parker, Jessica; Willekes, Charles L; Timek, Tomasz

    2018-03-01

    Minimally invasive aortic valve replacement (mAVR) is gaining clinical acceptance, however, it is associated with increased operative times due to limited surgical field and access. The Cor-Knot is an automated fastening device designed to facilitate suture fastening, but clinical data in mAVR are lacking. From May 2014 to February 2017, 92 patients underwent mAVR at our center with 39 valves secured with manually-tied (MT) sutures and 53 valves entirely secured with the Cor-Knot (CK). Pre-operative characteristics and 30-day outcomes data were extracted from our local Society of Thoracic Surgeons database and the electronic medical record. Survival data were obtained from the Michigan State Social Security Death Index. No significant difference in pre-operative characteristics were noted between the two groups. Aortic cross-clamp time (72±12 min vs 82±15 min, p=0.001) was significantly shorter with CK. There was no difference in post-operative mortality (0% vs 0%), stroke (0% vs 1.9%), atrial fibrillation (28% vs 33%), renal failure (0% vs 3.8%), or pacemaker implantation (5.1% vs 5.7%) between MT and CK. Valve function on post-operative echocardiography and 1-year patient survival were similar. In minimally invasive aortic valve replacement, the Cor-Knot device was associated with reduced aortic cross-clamp time while providing equivalent clinical outcomes. Larger studies are needed to confirm efficacy, safety, and cost-effectiveness of the Cor-Knot device in minimally invasive aortic valve surgery. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Recurrent acute pulmonary oedema after aortic and mitral valve surgery due to trachea malacia and obstructive sleep apnoea syndrome

    NARCIS (Netherlands)

    Sankatsing, S. U. C.; Hanselaar, W. E. J. J.; van Steenwijk, R. P.; Van der Sloot, J. A. P.; Broekhuis, E.; Kok, W. E. M.

    2008-01-01

    In this report we describe a patient with recurrent episodes of acute pulmonary oedema after aortic and mitral valve surgery. The first episode of pulmonary oedema was caused by mitral valve dysfunction. The second episode of pulmonary oedema was not clearly associated with a mitral valve problem,

  14. Aortic valve replacement with sutureless prosthesis: better than root enlargement to avoid patient-prosthesis mismatch?

    Science.gov (United States)

    Beckmann, Erik; Martens, Andreas; Alhadi, Firas; Hoeffler, Klaus; Umminger, Julia; Kaufeld, Tim; Sarikouch, Samir; Koigeldiev, Nurbol; Cebotari, Serghei; Schmitto, Jan Dieter; Haverich, Axel; Shrestha, Malakh

    2016-06-01

    Aortic valve replacement in patients with a small aortic annulus may result in patient-prosthesis mismatch (PPM). Aortic root enlargement (ARE) can reduce PPM, but leads to extended cardiac ischaemia times. Sutureless valves have the potential to prevent PPM while reducing cardiac ischaemia times. Between January 2007 and December 2011, a total of 128 patients with a small aortic annulus underwent surgery for aortic valve stenosis at our centre. Thirty-six (17% male, n = 6) patients received conventional valve replacement with ARE and 92 (16% male, n = 18) subjects received sutureless valve implantation (Sorin Perceval). We conducted a comparative, retrospective study with follow-up. The sutureless group showed a significantly higher age (79 years) than the ARE patients (62 years, P body surface area was 0.91 ± 0.2 cm(2)/m(2) in ARE patients and 0.83 ± 0.14 cm(2)/m(2) in sutureless patients (P = 0.040). The rate of patients with severe PPM was 6% (n = 2) in ARE patients and 11% (n = 8%) in sutureless patients (not significant, n.s.). The 30-day mortality rates were 2% (n = 2) in sutureless patients and 6% (n = 2) in ARE patients (n.s.). The 1- and 5-year survival rates of the sutureless group were 92 and 54% years, respectively, whereas the 1- and 5-year survival rates of the ARE group were 76% (n.s.). Although the sutureless valve patients received significantly more concomitant procedures, all operation-associated times were significantly shorter. Despite sutureless valve patients being older, the 30-day mortality and survival rates were comparable in the two groups. Since the indexed EOA was only slightly lower and the incidence of severe PPM was not significantly higher in the sutureless valve patients, we conclude that sutureless valve implantation is an alternative to conventional ARE to treat a small aortic annulus and avoid PPM, especially in geriatric patients who benefit from the quick implantation process. © The Author 2016. Published by Oxford

  15. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    : For each surgical type and label size, the two commonly used THV sizes, a given THV “standard” vs. a size larger “oversized” were compared among patients undergoing aortic ViV within VIVID Registry. The degree of THV perimeter oversizing was calculated as: (THV nominal size – surgical valve true ID...... group received a larger THV (25.5± 1.4 mm vs. 23.3 ± 1.0 mm, pdegree of THV oversizing (31% ± 10.6 vs. 20% ± 9.5, p=vs. 1.37± 0.5cm2, p....1±8.1mmHg vs. 17.4±8.5mmHg, p=0.002) in comparison to the standard cohort. The oversized group however, had a higher rate of moderate to severe AI (6.9% vs. 2.7%, p=0.001) and second THV requirement (5.5%vs. 2.2%, p=0.04). THV mal-positioning, coronary obstruction and postoperative pacemaker requirement...

  16. First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

    Science.gov (United States)

    Grube, Eberhard; Laborde, Jean C; Zickmann, Bernfried; Gerckens, Ulrich; Felderhoff, Thomas; Sauren, Barthel; Bootsveld, Andreas; Buellesfeld, Lutz; Iversen, Stein

    2005-12-01

    Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.7 cm2). Surgical valve replacement had been declined for the patient because of comorbidities, including previous bypass surgery. A retrograde approach via the common iliac artery was used for valve deployment. The contralateral femoral vessels were used for a temporary extracorporal circulation, unloading the left ventricle during the actual stent expansion. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially during the procedure. Clinical and echocardiographic follow-up at day 1, 2, and 14 post procedure was performed to evaluate the short-term outcome. The prosthesis was successfully deployed within the native aortic valve, with accurate and stable positioning and with no impairment of the coronary artery or vein graft blood flow. 2D and doppler echo immediately after device deployment showed a significant reduction in transaortic mean pressure gradient (from 45 to 8 mmHg) without evidence of aortic or mitral valve insufficiency. The clinical status has then significantly improved. These results remained unchanged up to the day 14 follow-up. This case report demonstrates a successful percutaneous implantation of a self-expanding aortic valve prosthesis with remarkable functional and clinical improvements in the acute and short-term outcome. Copyright (c) 2005 Wiley-Liss, Inc.

  17. Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI)

    Energy Technology Data Exchange (ETDEWEB)

    Schmidkonz, C., E-mail: christian.schmidkonz@gmail.com [Department of Internal Medicine 2 (Cardiology), University of Erlangen, Ulmenweg 18, D-91054 Erlangen (Germany); Marwan, M.; Klinghammer, L.; Mitschke, M.; Schuhbaeck, A.; Arnold, M. [Department of Internal Medicine 2 (Cardiology), University of Erlangen, Ulmenweg 18, D-91054 Erlangen (Germany); Lell, M. [Radiological Institute, University of Erlangen, Maximiliansplatz 1, D-91054 Erlangen (Germany); Achenbach, S.; Pflederer, T. [Department of Internal Medicine 2 (Cardiology), University of Erlangen, Ulmenweg 18, D-91054 Erlangen (Germany)

    2014-09-15

    Highlights: • Cardiac CT provides highly reproducible measurements of aortic annulus and root dimensions prior to TAVI. • The perimeter-derived aortic annulus diameter shows the lowest interobserver variability. • If all three CT sizing methods are considered and stated as a “consensus result”, mismatches in prosthesis size selection can be further reduced. - Abstract: Objective: Assessment of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI) is crucial for accurate prosthesis sizing in order to avoid prosthesis–annulus-mismatch possibly resulting in complications like valve dislodgement, paravalvular regurgitation or annulus rupture. Contrast-enhanced multidetector computed tomography allows 3-dimensional assessment of aortic annulus dimensions. Only limited data exist about its interobserver variability. Methods: In 100 consecutive patients with symptomatic severe aortic stenosis (51 male, BMI 27 ± 5 kg/m{sup 2}, age 81 ± 7 years, heart rate 72 ± 15 bpm, Logistic Euroscore 31 ± 14%, STS-Score 7 ± 4%), pre-interventional aortic annulus assessment was performed by dual source computed tomography (collimation 2 × 128 × 0.6 mm, high pitch spiral data acquisition mode, 40–60 ml contrast agents, radiation dose 3.5 ± 0.9 mSv). The following aortic annulus characteristics were determined by three independent observers: aortic annulus maximum, minimum and mean diameters (D{sub max}, D{sub min}, D{sub mean}), eccentricity index (EI), effective aortic annulus diameter according to its circumference (D{sub circ}), effective aortic annulus diameter according to its area (D{sub area}), distance from the aortic annulus plane to the left (LCA) and right coronary artery (RCA) ostia, maximum (D{sub max}AR) and minimum aortic root diameter (D{sub min}AR), maximum (D{sub max}STJ) and minimum diameter of the sinotubular junction (D{sub min}STJ). Subsequently, interobserver variabilities were assessed. Results: Correlation between

  18. Quadricuspid Aortic Valve: A Case Report and Review of the Literature.

    Science.gov (United States)

    Savino, Ketty; Quintavalle, Elisa; Ambrosio, Giuseppe

    2015-01-01

    The quadricuspid aortic valve (QAV) is a rare malformation; often isolated, sometimes associated with other heart diseases. Before the era of echocardiography, the diagnosis was made incidentally at autopsy or during surgery of valve replacement. The extensive use of echocardiography has allowed an early and accurate diagnosis of this malformation. In many cases, the transthoracic approach is suitable for the diagnosis but, transesophageal echocardiography is a tool for the accurate definition of the valve anatomy. This review analyzes, after the presentation of a clinical case, the current knowledge on embryogenesis, classification, diagnosis and clinical course of QAV.

  19. Patient-prosthesis mismatch has no influence on in-hospital mortality after aortic valve replacement.

    Science.gov (United States)

    Yottasurodom, Chaiwut; Namthaisong, Kriengkrai; Porapakkham, Pramote; Kasemsarn, Choosak; Chotivatanapong, Taweesak; Chaiseri, Pradistchai; Wongdit, Suwannee; Yasotarin, Suwanna

    2012-08-01

    To analyze the relationship between prosthetic aortic valve orifice and body surface area (Effective Orifice Area Index, EOAI) and in-hospital mortality after aortic valve replacement. A prospective study was conducted between October 2007 to September 2010, 536 patients underwent isolated aortic valve replacement (AVR) was recorded on preoperative, operative and postoperative data. Patient Prosthesis Mismatch (PPM) was classified by Effective Orifice Area Indexed (EOAI) by prosthetic valve area divided by body surface area as mild or no significance if the EOAI is greater than 0.85 cm2/m2, moderate if between 0.65 cm2/m2 and 0.85 cm2/m2, and severe if less than 0.65 cm2/m2. Statistical differences were analyzed by Chi-square and student t-test with p-value less than 0.05 considered significant. There were 304 men, mean age was 60.98 years, mean valve orifice area 1.69 cm2, body surface area 1.60 m2, cross clamp time 1.13 hrs., bypass time 1.67 hrs. Mechanical valves were used in 274 patients (51.2%) and Bioprosthesis were used in 181 patients (48.8%). PPM was found in 33.7%, 6.7% was severe PPM, 27% was moderate PPM and 66.3% has no significant PPM Over all in-hospital mortality was 1.5%. There was no significant difference in hospital mortality between no PPM group, moderate PPM and severe PPM group (1.4% vs. 1.4% vs. 5.4%, p-value = 0.86). In a large aortic valve surgery population, moderate and severe patient prosthesis mismatch occurred in 35.6% of patients but had no influence on in-hospital mortality.

  20. Numerical investigation on effect of aortic root geometry on flow induced structural stresses developed in a bileaflet mechanical heart valve

    Science.gov (United States)

    Abbas, S. S.; Nasif, M. S.; Said, M. A. M.; Kadhim, S. K.

    2017-10-01

    Structural stresses developed in an artificial bileaflet mechanical heart valve (BMHV) due to pulsed blood flow may cause valve failure due to yielding. In this paper, von-Mises stresses are computed and compared for BMHV placed in two types of aortic root geometries that are aortic root with axisymmetric sinuses and with axisymmetric bulb, at different physiological blood flow rates. With BMHV placed in an aortic root with axisymmetric sinuses, the von-Mises stresses developed in the valve were found to be up to 47% higher than BMHV placed in aortic root with axisymmetric bulb under similar physiological conditions. High velocity vectors and therefore high von-Mises stresses have been observed for BMHV placed in aortic root with axisymmetric sinuses, that can lead to valve failure.

  1. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.

    Science.gov (United States)

    Seiffert, Moritz; Conradi, Lenard; Baldus, Stephan; Knap, Malgorzata; Schirmer, Johannes; Franzen, Olaf; Koschyk, Dietmar; Meinertz, Thomas; Reichenspurner, Hermann; Treede, Hendrik

    2012-03-01

    Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. Eleven patients (aged 79.3 ± 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 ± 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% ± 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 ± 15.4 mm Hg before implantation to 21.2 ± 9.7 mm Hg at discharge (group 1) and from 28.2 ± 9.0 mm Hg before implantation to 15.2 ± 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 ± 0.1 cm(2)/m(2) to 0.6 ± 0.1 cm(2)/m(2) and from 0.6 ± 0.3 cm(2)/m(2) to 0.8 ± 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 ± 1.1 to 0.4 ± 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding

  2. Early and midterm results of upper ministernotomy approach for aortic valve replacement

    Directory of Open Access Journals (Sweden)

    I. Moursi

    2017-12-01

    Conclusions: The Upper mini-sternotomy for aortic valve surgery is an approach that offers many benefits. However, it is technically more complicated and requires a learning curve beyond which it can offer a lower complication rate with lower pain, blood loss and transfusion, and rapid return to normal activities.

  3. Prevalence and prognostic implications of baseline anaemia in patients undergoing transcatheter aortic valve implantation

    NARCIS (Netherlands)

    N.M. van Mieghem (Nicolas); R-J.M. Nuis (Rutger-Jan); A. Tzikas (Apostolos); N. Piazza (Nicolo); C.J. Schultz (Carl); P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter)

    2011-01-01

    textabstractAims: TAVI is a minimally invasive alternative to surgical aortic valve replacement or medical therapy in patients with a high or prohibitive operative risk. The clinical significance of baseline anemia and prognostic implications in this patient cohort are unknown. We sought to evaluate

  4. Protein-altering and regulatory genetic variants near GATA4 implicated in bicuspid aortic valve

    DEFF Research Database (Denmark)

    Yang, Bo; Zhou, Wei-Wu; Jiao, Jiao

    2017-01-01

    Bicuspid aortic valve (BAV) is a heritable congenital heart defect and an important risk factor for valvulopathy and aortopathy. Here we report a genome-wide association scan of 466 BAV cases and 4,660 age, sex and ethnicity-matched controls with replication in up to 1,326 cases and 8,103 controls...

  5. Can postoperative mean transprosthetic pressure gradient predict survival after aortic valve replacement?

    NARCIS (Netherlands)

    Koene, Bart M.; Hamad, Mohamed A. Soliman; Bouma, Wobbe; Mariani, Massimo A.; Peels, Kathinka C.; van Dantzig, Jan-Melle; van Straten, Albert H.

    In this study, we sought to determine the effect of the mean transprosthetic pressure gradient (TPG), measured at 6 weeks after aortic valve replacement (AVR) or AVR with coronary artery bypass grafting (CABG) on late all-cause mortality. Between January 1998 and March 2012, 2,276 patients (mean age

  6. Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement

    NARCIS (Netherlands)

    Koene, Bart M.; Hamad, Mohamed A. Soliman; Bouma, Wobbe; Mariani, Massimo A.; Peels, Kathinka C.; van Dantzig, Jan-Melle; van Straten, Albert H.

    2013-01-01

    Background: The influence of prosthesis-patient mismatch (PPM) on survival after aortic valve replacement (AVR) remains controversial. In this study, we sought to determine the effect of PPM on early (30 days) after AVR or AVR combined with coronary artery bypass grafting (AVR with CABG). Methods:

  7. Modified Sleeve Technique in Aortic Valve-Sparing Operation for Marfan Syndrome.

    Science.gov (United States)

    Wu, Yung-Szu; Hsieh, Shih-Rong; Wang, Chung-Chi; Tsai, Chung-Lin

    2018-03-22

    We devised a simple modification of the Florida Sleeve procedure to perform aortic valve-sparing surgery. This technique is simple, quick, effective, and safe. We used this technique in operations performed on two young patients with Marfan syndrome. The initial and short-term results were satisfactory.

  8. Silent ischemic brain lesions after transcatheter aortic valve replacement : lesion distribution and predictors

    NARCIS (Netherlands)

    Samim, Mariam; Hendrikse, Jeroen; van der Worp, H. Bart; Agostoni, Pierfrancesco; Nijhoff, Freek; Doevendans, Pieter A.; Stella, Pieter R.

    Silent ischemic brain lesions and ischemic stroke are known complications of transcatheter aortic valve replacement (TAVR). We aimed to investigate the occurrence and distribution of TAVR-related silent ischemic brain lesions using diffusion-weighted magnetic resonance imaging (DWI). Consecutive

  9. Relation of osteoprotegerin in severe aortic valve stenosis to postoperative outcome and left ventricular function

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2013-01-01

    ventricular (LV) function and remodeling and to evaluate the significance of preoperative OPG on long-term outcome in terms of survival and symptomatic improvement in 124 patients with severe AS scheduled for aortic valve replacement (AVR). Patients were divided according to tertiles of preoperative OPG...

  10. Reevaluation of the indications for permanent pacemaker implantation after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Bjerre Thygesen, Julie; Loh, Poay Huan; Cholteesupachai, Jiranut

    2014-01-01

    AIMS: Conduction abnormalities (CA) requiring permanent pacemaker (PPM) are a well-known complication after transcatheter aortic valve implantation (TAVI). This study aimed to determine the incidence of TAVI-related PPM and reevaluate the indications for PPM after the periprocedural period. METHODS...

  11. Natural history of subclinical leaflet thrombosis affecting motion in bioprosthetic aortic valves

    DEFF Research Database (Denmark)

    Sondergaard, Lars; De Backer, Ole; Kofoed, Klaus F

    2017-01-01

    Aims: Four-dimensional volume-rendered computed tomography (4DCT) has demonstrated instances of hypo-attenuating leaflet thickening (HALT) with or without hypo-attenuation affecting motion (HAM) after transcatheter and surgical aortic valve implantation (TAVI, SAVR). The temporal pattern of evolu...

  12. Three-dimensional transesophageal echocardiography in the evaluation of aortic valve destruction by endocarditis

    NARCIS (Netherlands)

    Nemes, Attila; Lagrand, Wim K.; McGhie, Jackie S.; ten Cate, Folkert J.

    2006-01-01

    Infective endocarditis remains a serious and complex disease with significant morbidity and mortality. The aim of this study was to demonstrate the clinical usefulness of 3-dimensional transesophageal echocardiography for the spatial assessment of aortic valve endocarditis. This case showed severe

  13. The systemic inflammatory response syndrome predicts short-term outcome after transapical transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Rettig, Thijs C D; Rigter, Sander; Nijenhuis, Vincent J.; Van Kuijk, Jan Peter; Ten Berg, Jurriën M.; Heijmen, Robin H.; Van De Garde, Ewoudt M W; Noordzij, Peter G.

    2015-01-01

    Objective Despite the minimally invasive nature of transcatheter aortic valve implantation (TAVI), the incidence of acute kidney injury (AKI) and mortality is of major concern. Several studies showed that outcome was influenced by the systemic inflammatory response syndrome (SIRS) in patients

  14. Polyamine concentration is increased in thoracic ascending aorta of patients with bicuspid aortic valve

    Czech Academy of Sciences Publication Activity Database

    Forte, A.; Grossi, Mario; Bancone, C.; Cipollaro, M.; De Feo, M.; Hellstrand, P.; Persson, L.; Nilsson, B.O.; Della Corte, A.

    Roč. 33, č. 3 ( 2017 ), s. 327-339 ISSN 0910-8327 Institutional support: RVO:68378050 Keywords : Aneurysm * Aortopathy * Bicuspid aortic valve * Ornithine decarboxylase * Polyamines * Thoracic ascending aorta Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.434, year: 2016

  15. The structure and material composition of ossified aortic valves identified using a set of scientific methods

    Science.gov (United States)

    Zeman, Antonín; Šmíd, Michal; Havelcová, Martina; Coufalová, Lucie; Kučková, Štěpánka; Velčovská, Martina; Hynek, Radovan

    2013-11-01

    Degenerative aortic stenosis has become a common and dangerous disease in recent decades. This disease leads to the mineralization of aortic valves, their gradual thickening and loss of functionality. We studied the detailed assessment of the proportion and composition of inorganic and organic components in the ossified aortic valve, using a set of analytical methods applied in science: polarized light microscopy, scanning electron microscopy, X-ray fluorescence, X-ray diffraction, gas chromatography/mass spectrometry and liquid chromatography-tandem mass spectrometry. The sample valves showed the occurrence of phosphorus and calcium in the form of phosphate and calcium carbonate, hydroxyapatite, fluorapatite and hydroxy-fluorapatite, with varying content of inorganic components from 65 to 90 wt%, and with phased development of degenerative disability. The outer layers of the plaque contained an organic component with peptide bonds, fatty acids, proteins and cholesterol. The results show a correlation between the formation of fluorapatite in aortic valves and in other parts of the human bodies, associated with the formation of bones.

  16. Intima-media thickness of the descending aorta in patients with bicuspid aortic valve

    Directory of Open Access Journals (Sweden)

    Johan Petrini

    2016-06-01

    Conclusions: Intima-media thickness of the descending aorta is not affected by aortic valve morphology (BAV/TAV; age is the main determinant of AoIMT. Genetic markers (SNPs known to influence IMT in the carotid artery seem to correlate to IMT in the descending aorta only in patients with TAV.

  17. Relation of aortic valve calcium to chronic kidney disease (from the Chronic Renal Insufficiency Cohort Study).

    Science.gov (United States)

    Guerraty, Marie A; Chai, Boyang; Hsu, Jesse Y; Ojo, Akinlolu O; Gao, Yanlin; Yang, Wei; Keane, Martin G; Budoff, Matthew J; Mohler, Emile R

    2015-05-01

    Although subjects with chronic kidney disease (CKD) are at markedly increased risk for cardiovascular mortality, the relation between CKD and aortic valve calcification has not been fully elucidated. Also, few data are available on the relation of aortic valve calcification and earlier stages of CKD. We sought to assess the relation of aortic valve calcium (AVC) with estimated glomerular filtration rate (eGFR), traditional and novel cardiovascular risk factors, and markers of bone metabolism in the Chronic Renal Insufficiency Cohort (CRIC) Study. All patients who underwent aortic valve scanning in the CRIC study were included. The relation between AVC and eGFR, traditional and novel cardiovascular risk factors, and markers of calcium metabolism were analyzed using both unadjusted and adjusted regression models. A total of 1,964 CRIC participants underwent computed tomography for AVC quantification. Decreased renal function was independently associated with increased levels of AVC (eGFR 47.11, 44.17, and 39 ml/min/1.73 m2, respectively, pAVC risk factors. Adjusted regression models identified several traditional and novel risk factors for AVC in patients with CKD. There was a difference in AVC risk factors between black and nonblack patients. In conclusion, our study shows that eGFR is associated in a dose-dependent manner with AVC in patients with CKD, and this association is independent of traditional cardiovascular risk factors. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Dynamic Three-Dimensional Geometry of the Aortic Valve Apparatus-A Feasibility Study

    NARCIS (Netherlands)

    Khamooshian, Arash; Amador, Yannis; Hai, Ting; Jeganathan, Jelliffe; Saraf, Maria; Mahmood, Eitezaz; Matyal, Robina; Khabbaz, Kamal R; Mariani, Massimo; Mahmood, Feroze

    OBJECTIVE: To provide (1) an overview of the aortic valve (AV) apparatus anatomy and nomenclature, and (2) data regarding the normal AV apparatus geometry and dynamism during the cardiac cycle obtained from three-dimensional transesophageal echocardiography (3D TEE). DESIGN: Retrospective

  19. Self-Expanding Transcatheter Aortic Valve System for Symptomatic High-Risk Patients With Severe Aortic Stenosis

    DEFF Research Database (Denmark)

    Reichenspurner, Hermann; Schaefer, Andreas; Schäfer, Ulrich

    2017-01-01

    BACKGROUND: The CENTERA transcatheter heart valve (THV) is a low-profile, self-expanding nitinol valve made from bovine pericardial tissue that is 14-F compatible with a motorized delivery system allowing for repositionability. OBJECTIVES: The pivotal study evaluated safety and efficacy of this THV....... Echocardiograms and computed tomography scans were reviewed by core laboratories. The primary endpoint was all-cause mortality at 30 days. RESULTS: Between March 25, 2015 and July 5, 2016, 203 patients with severe symptomatic aortic stenosis and increased surgical risk, as determined by the heart team, were...... is the low incidence of permanent pacemaker implantations. (Safety and Performance Study of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560)....

  20. Statins for progression of aortic valve stenosis and the best evidence for making decisions in health care.

    Science.gov (United States)

    Thiago, Luciana; Tsuj, Selma Rumiko; Atallah, Alvaro Nagib; Puga, Maria Eduarda dos Santos; de Góis, Aécio Flávio Teixeira

    2011-01-06

    In the Western world, calcified aortic valve stenosis is the most common form of valvular heart disease, affecting up to 3% of adults over the age of 75 years. It is a gradually progressive disease, characterized by a long asymptomatic phase that may last for several decades, followed by a short symptomatic phase associated with severe restriction of the valve orifice. Investigations on treatments for aortic valve stenosis are still in progress. Thus, it is believed that calcification of aortic valve stenosis is similar to the process of atherosclerosis that occurs in coronary artery disease. Recent studies have suggested that cholesterol lowering through the use of statins may have a salutary effect on the progression of aortic valve stenosis.

  1. Valve-sparing aortic root replacement in patients with Marfan syndrome enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions.

    Science.gov (United States)

    Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A

    2014-05-01

    The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.

  2. Valve Sparing Aortic Root Replacement in Patients with Marfan Syndrome Enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions

    Science.gov (United States)

    Song, Howard K.; Preiss, Liliana R.; Maslen, Cheryl L.; Kroner, Barbara; Devereux, Richard B.; Roman, Mary J.; Holmes, Kathryn W.; Tolunay, H. Eser; Desvigne-Nickens, Patrice; Asch, Federico M.; Milewski, Rita K.; Bavaria, Joseph; LeMaire, Scott A.

    2016-01-01

    Background The long-term outcomes of aortic valve sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. We sought to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). Methods At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 have undergone aortic root replacement. Patients who have undergone AVS procedures were compared to those who have undergone aortic valve replacing (AVR) procedures. Results AVS root replacement was performed in 43.5% of MFS patients and the frequency of AVS increased over the past 5 years. AVS patients were younger at the time of surgery (31.0 vs. 36.3 years, p=0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients. AVR patients were more likely to have had aortic valve dysfunction and aortic dissection as a primary indication for surgery. After mean follow-up of 6.2 (SD=3.6) years, none of the 87 AVS patients have required reoperation; in contrast, after mean follow up of 10.5 (SD=7.6) years, 11.5% of AVR patients have required aortic root reoperation. Aortic valve function has been durable with 95.8% of AVS patients with aortic insufficiency graded as mild or less. Conclusions AVS root replacement is performed commonly in the MFS population. The durability of the aortic repair and aortic valve function have been excellent to date. These results justify the continued use of the procedure in the elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future. PMID:25296451

  3. Calcific Aortic Valve Disease Is Associated with Layer-Specific Alterations in Collagen Architecture.

    Directory of Open Access Journals (Sweden)

    Heather N Hutson

    Full Text Available Disorganization of the valve extracellular matrix (ECM is a hallmark of calcific aortic valve disease (CAVD. However, while microarchitectural features of the ECM can strongly influence the biological and mechanical behavior of tissues, little is known about the ECM microarchitecture in CAVD. In this work, we apply advanced imaging techniques to quantify spatially heterogeneous changes in collagen microarchitecture in CAVD. Human aortic valves were obtained from individuals between 50 and 75 years old with no evidence of valvular disease (healthy and individuals who underwent valve replacement surgery due to severe stenosis (diseased. Second Harmonic Generation microscopy and subsequent image quantification revealed layer-specific changes in fiber characteristics in healthy and diseased valves. Specifically, the majority of collagen fiber changes in CAVD were found to occur in the spongiosa, where collagen fiber number increased by over 2-fold, and fiber width and density also significantly increased. Relatively few fibrillar changes occurred in the fibrosa in CAVD, where fibers became significantly shorter, but did not otherwise change in terms of number, width, density, or alignment. Immunohistochemical staining for lysyl oxidase showed localized increased expression in the diseased fibrosa. These findings reveal a more complex picture of valvular collagen enrichment and arrangement in CAVD than has previously been described using traditional analysis methods. Changes in fiber architecture may play a role in regulating the pathobiological events and mechanical properties of valves during CAVD. Additionally, characterization of the ECM microarchitecture can inform the design of fibrous scaffolds for heart valve tissue engineering.

  4. Acute improvement in arterial-ventricular coupling after transcatheter aortic valve implantation (CoreValve) in patients with symptomatic aortic stenosis.

    Science.gov (United States)

    Di Bello, Vitantonio; Giannini, Cristina; De Carlo, Marco; Delle Donne, Maria Grazia; Nardi, Carmela; Palagi, Caterina; Cucco, Cuono; Dini, Frank Lloyd; Guarracino, Fabio; Marzilli, Mario; Petronio, Anna Sonia

    2012-01-01

    The recent development of transcatheter aortic valve implantation (TAVI) to treat severe aortic stenosis (AS) offers a viable option for high-risk patients categories. Our aim is to evaluate the early effects of implantation of CoreValve aortic valve prosthesis on arterial-ventricular coupling by two dimensional echocardiography. Sixty five patients with severe AS performed 2D conventional echocardiography before, immediately after TAVI, at discharge (mean age: 82.6 ± 5.9 years; female: 60%). The current third generation (18-F) CoreValve Revalving system (Medtronic, Minneapolis, MN) was used in all cases. Vascular access was obtained by percutaneous approach through the common femoral artery; the procedure was performed with the patient under local anesthesia. We calculated, apart the conventional parameters regarding left ventricular geometry and the Doppler parameters of aortic flow (valvular load), the vascular load and the global left ventricular hemodynamic load. After TAVI we showed, by echocardiography, an improvement of valvular load. In particular we observed an immediate reduction of transaortic peak pressure gradient (P < 0.0001), of mean pressure gradient (P < 0.0001) and a concomitant increase in aortic valve area (AVA) (0.97 ± 0.3 cm(2)). Left ventricular ejection fraction improved early after TAVI (before: 47 ± 11, after: 54 ± 11; P < .0001). Vascular load, expressed by systemic arterial compliance, showed a low but significant improvement after procedure (P < 0.01), while systemic vascular resistances showed a significant reduction after procedure (P < 0.001). As a global effect of the integrated changes of these hemodynamic parameters, we observed a significant improvement of global left ventricular hemodynamic load, in particular through a significant reduction of end-systolic meridional stress (before: 80 ± 34 and after: 55 ± 29, P < 0.0001). The arterial-valvular impedance showed a significant reduction (before: 7.6 ± 2 vs after: 5.8 ± 2

  5. Arterial hypertension and aortic valve stenosis: Shedding light on a common “liaison”

    Directory of Open Access Journals (Sweden)

    Charalampos I. Liakos, MD, PhD

    2017-07-01

    Full Text Available Arterial hypertension and aortic valve stenosis are common disorders and frequently present as concomitant diseases, especially in elderly patients. The impact of hypertension on heart haemodynamics is substantial, thus affecting the clinical presentation of any coexisting valvulopathy, especially of aortic stenosis. However, the interaction between these 2 entities is not thoroughly discussed in the European or/and American guidelines on the management of hypertension or/and valvular heart disease. The present review summarizes all available evidence on the potential interplay between hypertension and aortic valve stenosis, aiming to help physicians understand the pathophysiology and select the best diagnostic and therapeutic strategies (medical or/and interventional for better management of these high-risk patients, taking into account the impact on outcome as well as the risk-benefit-ratio.

  6. National trends in utilization and in-hospital outcomes of mechanical versus bioprosthetic aortic valve replacements.

    Science.gov (United States)

    Isaacs, Abby J; Shuhaiber, Jeffrey; Salemi, Arash; Isom, O Wayne; Sedrakyan, Art

    2015-05-01

    Substantial controversy surrounds the choice between a mechanical versus bioprosthetic prosthesis for aortic valve replacement (AVR), based on age. This study aims to investigate national trends and in-hospital outcomes of the 2 prosthesis choices. All patients aged >18 years in the National Inpatient Sample who received an AVR between 1998 and 2011 were considered. Valve-type use was examined by patient, procedural, and hospital characteristics, after which we matched patients based on their propensity score for receiving a bioprosthetic valve and compared their in-hospital outcomes. Bioprosthetic valves comprised 53.3% of 767,375 implanted valves, an increase in use from 37.7% in the period 1998 to 2001 to 63.6% in the period 2007 to 2011. The median age was 74 years for patients receiving bioprosthetic valves, and 67 years for those receiving mechanical valves. Use of bioprosthetic valves increased across all age groups, most markedly in patients age 55 to 64 years. Compared with patients receiving mechanical valves, these patients had a higher incidence of renal disease (8.0% vs 4.2%), coronary artery disease (58.5% vs 50.5%), concomitant coronary artery bypass grafting (46.7% vs 41.9%), and having surgery in a high-volume (>250 cases per year) center (31.3% vs 18.5%). Patients receiving bioprosthetic valves had a higher occurrence of in-hospital complications (55.9% vs 48.6%), but lower in-hospital mortality (4.4% vs 4.9%) than patients receiving mechanical valves. This difference was confirmed in propensity-matched analyses (complications: 52.7% vs 51.5%; mortality: 4.3% vs 5.2%). Use of bioprosthetic valves in AVR increased dramatically from 1998 to 2011, particularly in patients age 55 to 64 years. Prosthesis selection varied significantly by facility, with low-volume facilities favoring mechanical valves. Aortic valve replacement with a bioprosthetic valve, compared with a mechanical valve, was associated with lower in-hospital mortality. Copyright © 2015