WorldWideScience

Sample records for i-131 dosimetria especifica

  1. Evaluation of detectors for blood bioanalysis in Lu-177 and I-131 therapies for bone marrow dosimetry; Avaliacao de detectores para bioanalise de sangue em terapias com Lu-177 and I-131 para dosimetria de medula ossea

    Degenhardt, Amilie Louize

    2016-10-01

    The measures traceability is mandatory for minimizing uncertainties in internal dosimetry for radiopharmaceuticals clinical studies and ensures the quality of the standard. Equipment should have resolution and efficiency compatible with radionuclides energies and, additionally, be able to quantify variations in human bodies' activities samples since the initial administration near the minimum residual activities. For testing three equipment (ionization chamber Capintec 25R, sodium iodine scintillator LTI Genesys Gamma-1 and high hyperpure germanium detector Canberra), they were prepared Lu-177 and I-131 radiation sources simulating patient's blood samples activities by adopting the following hypothesis: (1) initial activities according the Brazilian protocols; (2) blood volume in the whole body (5.3 L for adult men and 1.4 L for 5 years-old children); (3) effective half-lives (1.61 h and 42.9 h for Lu-177 bi-exponential adjustment and 15.7 h for I-131 mono-exponential adjustment); (4) sampling between 30 min and 168 h; (v) blood density adjustments. The standard sources were measured in the secondary standard ionization chamber Centronics IG11 at the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes. The Capintec ionization chamber efficiencies ranged, respectively for I-131 and Lu-177, between (111.58±0.02)% and (102.27±0.01)% and HPGe semiconductor detector efficiencies ranged, respectively, between (89.40±0.03)% and (87.80±0.04)%. For the NaI detector, when the Lu-177 sources were positioned inside the detector the efficiencies ranged between (12.66±0.01)% and (11.54± 0.07)% and when the sources were positioned at 5 cm and 10 cm from the detector the efficiencies decreased to less than 5%. For I-131 sources positioned inside the detector, the efficiencies ranged between (29.76±0.21)% and (30.20±0.04)% and they decreased to less than 5% when they were positioned at 5 cm and 10 cm from the detector (deviation greater than 95

  2. Course of training in Specific internal dosimetry for the patient; Curso de capacitacion en dosimetria interna especifica para el paciente

    Rojo, A.M.; Michelin, S.C. [Dosimetria Interna, Autoridad Regulatoria Nuclear, Av. Del Libertador 8250 CP (429BNP), Buenos Aires (Argentina); Gomez P, I.M. [Sociedad Argentina de Radioproteccion, Av. del Libertador 8250, Buenos Aires (Argentina)]. e-mail: arojo@cae.arn.gov.ar

    2006-07-01

    In this work the experience obtained in a course organized in Argentina to qualify professionals in the radiopharmaceutical dosimetry using the methodology MIRD and the patient's images is presented. The motivation to carry out it was based on the continuous development of new radiopharmaceuticals with therapeutic purposes that makes necessary the knowledge of the distribution of the absorbed dose to be able to establish the dose-response relationship. The main objective was the study of the biokinetic model and those techniques available that starting from images can contribute information of specific parameters of the patient to calculate with more accuracy the doses in the tumor and in different organs. In the design of the program of this course it was considered to approach the different focuses for the calculation of specific dose of the patient and includes the following topics: the patient's radiological protection, new concepts in damages by radiations (bystander effect), methodology for the internal dosimetry by radiopharmaceuticals, dosimetric systems (MIRD/ICRP), revision of the physical phantoms, design of kinetic studies, compartmental models, calculation tools and the demonstration of the programs SAAM and OLINDA; calculation of activity starting from the patient's images (planar and SPECT). Principles of the gamma camera: the dispersed radiation, calculation of the activity with planar images, the attenuation, correction of the dispersed radiation, collimation problems. SPECT: the common method of reconstruction, basic principles, method of filtered over head projection and iterative methods (MLEM/OSEM), measurement of the attenuation maps, problems of the penetration in the collimator (I-131, I-123), effects of partial volume, incorporation of corrections in an iterative reconstruction. Dosimetry in bone marrow, discussion of study cases of new radiopharmaceuticals. Internal dosimetry in small scale for electrons and photons

  3. Software for dosimetry hypothyroid patients treated with I131 pick up and using probe gamma camera; Software para la dosimetria de pacientes hipertiroideos tratados con 131I utilizando sonda de captacion y gammacamara

    Jimenez Felstrom, D.; Luis simon, J.; Reyes Garcia, R.; Derecho Torres, P.; Herrador Cordoba, M.

    2015-07-01

    In this communication the process recently implemented in our hospital for pre and post treatment of patients treated with I-131 in benign diseases of the thyroid gland internal dosimetry is described. We have developed a proprietary software that facilitates the process of dosimetry. Through scans Planar or pictures Spect be determines the mass of the gland thyroid. In function of the mass, is calculated by Monte Carlo the media power absorbed by disintegration of the I-131 in said gland endocrine. (Author)

  4. Radioactive Iodine (I-131) Therapy for Hyperthyroidism

    ... Physician Resources Professions Site Index A-Z Radioactive Iodine (I-131) Therapy Radioiodine therapy is a nuclear ... thyroid cancer. When a small dose of radioactive iodine I-131 (an isotope of iodine that emits ...

  5. Recurrent thyrotoxicosis after I-131 induced hypothyroidism

    Liu, L.; Borowski, G.D.; Shtasel, P.; Rose, L.I.

    1984-01-01

    The first clinically and biochemically documented case of recurrent thyrotoxicosis after I-131 induced hypothyroidism in a patient with Graves' disease is reported. Two months after the administration of 9.2 mCi of I-131, the subject developed hypothyroidism. One month later, the patient became euthyroid. Then, nine months following ablation, the patient again developed thyrotoxicosis. A second dose of I-131 of 12.5 mCi was required to finally produce permanent hypothyroidism. This case illustrates the recurrence of hypothyroidism after what had seemed to have been adequate I-131 radiation

  6. I-131 and thyroid-associated ophthalmopathy

    Rasmussen, Aase Krogh; Nygaard, Birte; Feldt-Rasmussen, Ulla

    2000-07-01

    Objective: Radioiodine (I-131) used to obtain euthyroidism in thyrotoxic patients is suspected of having a worsening or provoking effect on thyroid-associated ophthalmopathy (TAO), an autoimmune disease closely related to Graves' disease. Design: This review summarises the existing literature and describes risk factors influencing the course of TAO including thyroid function, cigarette smoking and treatment of Graves' hyperthyroidism especially I-131 therapy. Conclusion: It is recommended that patients who may be at a greater risk of worsening ophthalmopathy are considered when choosing the modality of therapy of hyperthyroidism and also in deciding whether prophylactic systemic glucocorticoid treatment is indicated.

  7. Radiation exposure in I-131 iodine therapy

    Friedrich, W.

    1985-01-01

    In the past five years, the applied I-131 radioactivity quantity has doubled with a constant number of beds. In 1984, it was 925 GBq (25 Ci). Despite this development, no changes in the professional radiation exposure were made out. The evaluation shows a dose smaller than 0.04 man Sv/TBq (0.16 man rem/Ci) of I-131 applied. This value is below the traceability limit of the film badges. The incorporation load of the personnel (27 members) was determined by monthly body counter measurements. Only in one measurement thyroid gland activity of 5 kBq (140 nCi) was detected. Most measurements did not show any incorporation; and the few positive results were below 0.74 kBq (20 nCi). The environmental load due to unfiltered release from patients' rooms was determined at the fence of the nuclear research plant. The maximum was 0.24 mSv/a thyroid gland dose of a small child in 1982 taking into account the measured 90% partion of organic compound iodine. The waste water is decayed following chemical treatment in storage tanks. (orig./HP) [de

  8. Radiopharmaceutical potential of I-131 labelled diazepam

    Yurt, F.; Unek, P.; Asikoglu, M.; Baggi, S.; Erener, G.; Ozkilic, H.; Uluc, F.; Tuglular, I.

    1998-01-01

    In this study, diazepam is a derivative of the 1.4 benzodiazepine family that the most widely used drug as anticonvulsant agent has been labeled with I-131, as a new radiopharmaceutical and its radiopharmaceutical potential has been determined. Labeling of diazepam has been performed by iodogen method and optimum labeling conditions have been determined. Optimum reaction conditions are 1 mg for iodogen amount; 1-5 mg for diazepam amount, 15-20 minutes for reaction time and room temperature for reaction temperature. Specific activity of labeled compound was 0,15 Ci/mmol level. N-octanol/water ratio was found 1.9 for 131 IDZ ( 131 I labeled diazepam). In vivo experiments have been carried out to determine radiopharmaceutical potentials of labeled compound. Biodistribution studies on rats showed that 131 IDZ have accumulated in kidneys, liver, lungs and brain tissues. Scintigraphic results taken with gamma camera on rabbits agree with biodistribution results of rats. (author)

  9. Migration of radionuclide I-131 through a clayey porous matrix

    Hamlat, M.S.

    1996-01-01

    The chemical and physical behavior of the radiotracer I-131 through a porous matrix are described. The study was evaluated using the laboratory column, which contains porous soils. The collected activities have been measured by gamma counting with a NaI(Tl) detector. The indicators were observed and analyzed by using the one dimension mass transport equation. The solution was utilized to interpret the obtaining experimental data. The experimental values of I-131 are in agreement with those calculated by the model. However, the utilization of (I-131) in the punctual hydrogeological studies is proved. (author). 5 refs., 2 figs., 2 tabs

  10. Get the Facts About Exposure to I-131 Radiation

    ... Data Conducting Clinical Trials Statistical Tools and Data Terminology Resources NCI Data Catalog Cryo-EM NCI's Role ... affected by I-131 fallout from nuclear testing. Medical signs —A lump or nodule that an individual ...

  11. Three cases of respiratory failure after I-131 radioiodine therapy

    Watanabe, Ken; Uchiyama, Masayuki; Fukuda, Kunihiko

    2016-01-01

    We report three cases of respiratory failure after I-131 radioiodine therapy. All cases involved relapsed cervical lesions, and two showed edema of the larynx. Emergency tracheostomy was performed to treat the respiratory failure in one case while the others were treated conservatively. All patients showed improvements without after-effects. Patients who undergo I-131 radioiodine therapy, especially those with cervical lesions, should be carefully monitored for this rare complication after treatment. (author)

  12. Calculated activity incorporated in the therapy with I131

    Chica, L.G.; Puerta, J.A.

    1998-01-01

    By means of the product S(T→ S).A s (T e ), the absorbed dose to thyroid delivered by I 131 incorporated is calculated. Where S(T→ S) is the absorbed dose in the thyroid per nuclear transformation (tn.) of I 131 localized in the thyroid and as a potential function of the mass is expressed. A s (T e ) is the number of tn. of I 131 in the thyroid since the moment of the incorporation until the time T e (the effective middle time); to find A s (T e ) to normal as different pathological conditions, the metabolic model of the iodo proposed by the ICRP is used. Of the expressions of the doses, the incorporated activity, l o , is obtained

  13. Radiation exposure estimation from patient treated by I-131

    Lahfi, Y.; Anjak, O.

    2012-09-01

    Radioactive iodine is the main radiopharmaceutical substance in the nuclear medicine field which used in diagnosis and treatment of patients suffering from thyroid cancer; thus it can be considered as the main source of the public and patient relative exposure. In this study, 192 patients were selected randomly and their radiation dose rate was measured at different levels of the patient's body (thyroid, knee, bladder) after one, twenty four and forty eight hours from availing the prescript quantity of the I-131. The collected data may serve in estimating the worker and public exposure related to the patient treated by I-131. (authors)

  14. The Relative Frequency of Persistent Hyperthyroidism After I131Therapy

    Al-EID, M.A.

    1998-01-01

    517 patients with different types of hyperthyroidism who had treated by I 131 therapy were studied. The study demonstrated that diffuse toxic goiter was the most common type of hyperthyroidism. The relative frequency of persistent hyperthyroidism in all types after the first dose of I 131 utilizing our empirical regimen in estimation of therapy doses was low (9.5%). While high frequency of persistent hyperthyroidism among diffuse toxic goiter patients (14%), probably was due to many factors discussed in this paper. Some of these factors are impossible to be estimated precisely and therefore, can not be avoided. But careful dose estimation for each case with diffuse toxic goiter may reduce the rate of retreatment by I 131 . Antithyroid medication prior to I 131 therapy might be another factor resulted in increasing of retreatment of retreatment rate diffuse toxic goiter cases. Longer time interval (more than 5 days) of ceasing antithyroid medication prior therapy is suggested to avoid the effects of these drugs. Patients with other types of hyperthyroidism were not frequently required more than one dose and the frequency of persistent hyperthyroidism was almost negligible

  15. Experimental radioimmunotherapy with I-131-antibody against a differentiation antigen

    Badger, C.C.; Krohn, K.A.; Bernstein, I.D.

    1985-01-01

    The authors have previously shown that I-131-labeled antibodies (Ab) against the Thyl.l antigen can care AKR/Cu (Thyl.2+) mice bearing the AKR/J (Thy 1l.1+) SL2 T-cell lymphoma. The authors have now extended these studies to therapy with I-131-anti-Thyl.1 of SL2 lymphoma in AKR/J mice where Ab reacts with both tumor and normal cells. A 25 μg bolus was rapidly cleared from serum by binding to spleen cells (75% with Tl/2 <60 min.) and only low concentrations of Ab(<2% ID/gm) were present in tumor after infusion. Therapy of AKR/J mice bearing established s.c. lymphoma nodules with 1500 μCi I-131-anti-Thyl.1 resulted in complete regression of the nodule in 6/6 animals although tumor eventually regrew and all animals died of metastatic lymphoma. In contrast, I-131-irrelevant Ab given to produce the same amount of whole body radiation (750 μCi) did not affect tumor growth. These studies suggest that radiolabeled-AB against differentiation antigens may be useful for therapy in spite of binding to normal cell populations

  16. Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131

    Park, Seok Gun [Dankook University, Cheonan (Korea, Republic of)

    2008-12-15

    Effective half life of I-131 (T{sub eff}) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about T{sub eff} in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated T{sub eff}. Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=47{+-}13.7) treated by I-131 (3.7{approx}7.4 GBq) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, T{sub eff}, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. T{sub eff} was 15.4{+-}4.3 hr (9.4{approx}32.5 hr). There was a loose correlation between T{sub eff} and serum creatinine concentration (r=0.45). 48hr retention was 4.9{+-}4.2% (1{approx}23%). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as 47.1{+-}13.2 hr for 9.25 GBq, 42.1{+-}11.9 hr for 7.4 GBq, 35.7{+-}10.0 hr for 5.55 GBq, and 26.7{+-}7.5 hr for 3.7 GBq dose of I-131. Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, T{sub eff} and some other indices were calculated.

  17. Microwave assistance of labeling hippuric acid by I-131

    Sherlock Huang, Lin-Chiang; Wu, Kou-Hung; Ko, Pi-Wen; Hsieh, Cheng-Ying; Pao, Kuan-Chuan; Chou, Shih-Ching; Shieh, Fa-Kuen; Sureshbabu, Radhakrishnan; Hsu, Ming-Hua

    2014-01-01

    This work presents a novel approach for labeling hippuric acid with I-131 using microwaves. It utilizes copper(II) acetate as a catalyst of the labeling. The process involves the use of this catalytic copper(II) acetate at low dilutions that were nevertheless sufficient to produce labeled hippuric acid with high radiochemical purity in a short time. Therefore, the novel technique overcomes the limitations of previously reported conventional methods that involve heating. - Highlights: • We report the microwave assisted radiochemical labeling of hippuric acid by I-131. • Cu(OAc) 2 can be used as catalyst to get labeled product in lower dilution condition. • Advantages of our method are lesser time scale and high radiochemical purity.

  18. Present state of the I-131-MIBG therapy

    Fischer, M.

    1986-01-01

    Treatment of malignant pheochromocytoma and neuroblastoma stage III and IV is unsatisfactory. Locally invasive tumors may be cured by radical extirpation. The role of irradiation and/or chemotherapy in malignant pheochromocytoma is disappointing, in neuroblastoma in many cases debatable. From 1981 to the present we studied more than 250 patients by MIBG scintigraphy. 5 patients with malignant pheochromocytoma, one female patient with an intra-adrenal, probably benign pheochromocytoma and 3 children with neuroblastoma stage IV were treated with I-131-MIBG

  19. Treatment of Graves' disease with I131: Case Report

    Sanchez Povis, J.E.; Sandoval Okuma, J.C.; Contreras Carreno, S.E.; Cabello Morales, E.

    2006-01-01

    Objective: To describe the response and complications in children and teenagers suffering Graves' disease who received radioactive iodine therapy. Material and Methods: The clinical records of the patients attended at Paediatric Endocrinology Unit of Hospital Nacional Cayetano Heredia who received therapy with I 131 were reviewed. Demographic characteristics, thyroid weight, radioactive iodine uptake, I 131 dose and clinical and thyroid function evolution were registered. Results: We include thirteen patients: 1 male and 12 females. The mean thyroid weight obtained was 47.56 ± 10.70 gr. Initial calculated dose was 3.92 ± 0.95 mCi, with a total dose of 4.47 ± 1.66 mCi, and mean following period of 2.76 years. Ten patients received only one dose, 2 patients received two doses and one patient received three doses; all cases remitted. Patients who received only 1 dose showed disease remission at 13.13 weeks and mean remission period of the population was 24.62 weeks. Hypothyroidism prevalence up to six months from initiating treatment was 66.66%, and up to 257 weeks 83.33%. Conclusions: We conclude that I 131 was 100% effective in the treatment of children and adolescents suffering Graves' disease in this small series. (author)

  20. Distribution and Bioaccumulation of I-131 Within The Water-Fish System

    Darussalam, M; Wijaya, DGO; Sutrisno

    1996-01-01

    Distribution and Bioaccumulation of I-131 Within The Water-Fish System. As one of fission products, radioiodine I-131 potentially become a pollutant either resulted froma fallout or radioactive waste. Therefore, special interest has been given to handle I-131 starting from its production implementation and its waste management. The observations in this research have been focussed on distribution and bio accumulation of I-131 within the water-fish systems. Some number of Tilapia fish were put in aquaria containing I-131 contamined water with certain radioactivity concentration. Within time interval of 0, 6, 24, 48 and 72 hours after treatment the radioactivities of water media. fish and their organs have been measured. The results show that the radioactivity percentage different water media containing different I-131 concentration tend to have similar patterns. Meanwhile, the I-131 concentrations of fish and their organs were varied with similar patterns for different I-131 content in water media

  1. Comparison of thallium-201, Tc-99m MIBI and I-131 scan in the follow-up assessment after I-131 ablative therapy in differentiated thyroid cancer

    Kwon, Jae Sung; Lee, Sung Keun; Kim, Doe Min; Park, Sae Jong; Jang, Kyong Sun; Kim, Eun Sil; Kim, Chong Soon

    1999-01-01

    We conducted a comparative study to evaluate the diagnostic values of Tl-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or more times of I-131 retreatment (33 cases). In all patients, Tl-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Positive rates (PR) of Tc-99m MIBI, Tl-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant Tl-201 and I-131 scans were in the order of therapeutic 131 scan 71%, Tl-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between Tl-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. Tl-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these

  2. Vocal cord paralysis following I-131 ablation of a postthyroidectomy remnant

    Lee, T.C.; Harbert, J.C.; Dejter, S.W.; Mariner, D.R.; VanDam, J.

    1985-01-01

    Vocal cord paralysis has been reported following I-131 therapy of thyrotoxicosis and following ablation of the whole thryoid. However, this rare complication has not previously been described following I-131 ablation of a postthyroidectomy remnant. The authors report a patient who required tracheostomy for bilateral vocal cord paralysis following I-131 ablation after near-total thyroidectomy for papillary thyroid carcinoma

  3. Dosimetry prior to I-131-therapy of benign thyroid disease

    Haenscheid, Heribert; Lassmann, Michael; Reiners, Christoph

    2011-01-01

    The activity to be administered in I-131 therapy of benign thyroid disease is determined by the radiation absorbed dose necessary to cure the disease, the target mass, and the residence time of the I-131 in the target volume. Data from 73 patients with complete sets of uptake measurements 2, 6, 24, 48, and 96 (n = 53) or 120 (n = 20) hours after oral administration of 1 MBq I-131 were used to deduce residence times from subsets of 3, 2, or only 1 measurement for each individual. The values were compared to those obtained with the reference method, i.e. a fit of an uptake function based on a 2-compartment model to all 5 measurements, to quantify the errors introduced by the less demanding assessments. Deviations are less than 10% if the 2- compartment uptake function is fitted to only 3 values measured after 6, 24, and 96-120 h. Use of 2, 24, and 96-120 h data results in errors > 20% in individual patients. The effective half-lives as determined from 2 measurements after 24 and 96-120 h correlate well with those deduced from the reference method with larger deviations in individuals with slow iodine kinetics and late maximal uptake. Residence times determined from the 24 h uptake, assuming linear increase during the first day, and the effective half-life limited to maximum 8 days underestimate the actual values systematically in patients with long and short half-lives. These errors can be eliminated by a modification of the calculation method resulting in deviations less than 14% in all but one individual for this procedure. The accuracy of methods based on only one retention value increases with the time of measurement after the administration of I-131. While systematic errors up to a factor of two occur if the 24 h uptake is used for the estimate, deviations are less than 18% for measurements after 120 h. The results suggest that only one late uptake assessment warrants residence time estimates with an acceptable error. Given the high inherent uncertainties in the

  4. Radioiodine (I-131) therapy in thyroid cancer differentiated type (abstract)

    Khan, M.S.

    1999-01-01

    Carcinoma thyroid is not an uncommon malignancy in Pakistan because of its location in iodine deficient terrain. Painless palpable (solitary) thyroid nodule is the common presentation in majority (>90%) of the patients and > 25% cold nodules in females turned malignant on biopsy whereas in males >75% of cold nodules turned malignant on historical examination. The disease is more common in females as compared to males (3:1) and in females pure papillary carcinoma is more common whereas in males mostly follicular or mixed tumors are seen. Radical surgery (thyroidectomy) is not a routine surgical treatment in our country. In teaching hospitals the routine surgical procedure is lobectomy and Isthmectomy, whereas in DHQ Hospitals less surgical procedures, e.g. tumorectomy or partial labectomy etc. are done. Therefore, in view of limited/partial surgical ablation, I-131 ablation is mandatory for better and longer survival. We have treated 118 patients of thyroid carcinoma (Differential type) at our centre (AEMC) with therapeutic dose of Radioactive iodine (I-131) during the last 13 years with encouraging results (Disease free survival). (author)

  5. Calibration of filters for detection of airborne I-131 in the environment of nuclear power plant; Kalibracija filtrov za detekcijo I-131 v zraku okolja jedrske elektrarne

    Zupan, M; Miklavzic, U; Pucelj, B [Institut Jozef Stefan, Ljubljana (Yugoslavia)

    1982-07-01

    A simple and clean method for efficiency calibration of filters for collection of airborne I and corresponding Ge(Li) spectrometer is described. As the calibrated source of gaseous I-131 the radiopharmaceutical water solution of NaI is used. As calibration example the absolute activity distribution of I-131 measured in a charcoal filter is shown. (author)

  6. I-131 rose bengal excretion test is not dead

    Antico, V.F.; Denhartog, P.; Ash, J.M.; Gilday, D.L.; Houle, S.

    1985-01-01

    One hundred and thirty I-131 Rose Bengal Excretion Studies (RBI) were performed on 84 patients over nine years. In 90% (56/60) of cases with biliary atresia, the 72-hour RBI was less than or equal to 7%. In only 12.5% (3/24) of cases with neonatal hepatitis was the 72-hour RBI less than or equal to 7%. The accuracy of the test was 91% with a specificity of 88%. Thirty patients later were studied following a Kasai procedure. The RBI test reliably predicted the patency of the anastomosis. The authors conclude that the 72-hour RBI is a reliable test in the diagnosis of biliary atresia and in the documentation of biliary patency following surgery, provided adequate care is taken in stool collection and measurement

  7. Reducing radiation exposure during oral I-131 therapy administration

    Trujillo, J.; Krinsky, S.; Wilson, B.; Teague, E.

    1982-01-01

    A new, closed-system method to reduce air-, direct-, and incidental-contamination during therapeutic administration of oral I-131 was experimentally evaluated on twelve patients. We studied a standard control population using the routine practice of drinking the solution through a straw and compared results with our new technique. Various measurements were performed throughout all phases of dose administration to assess the relative difference of the two approaches. Using the closed system method before and during iodine administration revealed between 100 and 1000 times less activity per millimeter of air sample; whereas, the direct radiation exposure values were higher for the control population. Both the experimental and control methods had similar levels of incidental contamination

  8. Investigations on the retention of I-131 by an iodine filter of a pressurized water reactor

    Deuber, H.; Gerlach, K.

    1984-01-01

    The retention of I-131 by an equipment room exhaust filter of a German pressurized water reactor was determined by various methods to particularly obtain reliable results. Moreover, investigations were performed to clarify the reason for aging of the carbon contained in the iodine filter mentioned. The actual retention of the organic I-131, corresponding to a value of 99.9%, was limited by I-131 in the form of penetrating iodine compounds. It was lower than the retention of CH 3 I-131 under layout conditions by more than one order of magnitude. The aging was essentially caused by the adsorption of low-volatile organic compounds. (orig.) [de

  9. Radioiodine (I-131) therapy and the influence of antithyroid medication

    Duldulao, M.

    2007-01-01

    Full text: Radioiodine therapy began to play a major role in the management of hyperthyroidism as early as 1941. It later evolved to become what it is today, the treatment of choice for majority of patients who are suffering from Graves' disease and toxic nodular goiter. It is generally considered safe, inexpensive, effective, and devoid of major side effects. Despite the extensive experience with radioactive therapy, the adjunctive role of antithyroid medication remains controversial. Some authors claim that it has a positive influence on the outcome of radioiodine therapy while others insist otherwise. The reasons behind the adjunctive use of antithyroid medication include a more rapid attainment of euthyroid state and a decrease in the rise of developing thyroid crisis. However, a higher treatment failure rate is observed compared to radioiodine alone. This is due to the reputed radioprotective effect of the antithyroid medication. As a result, higher doses of I-131 are needed in order to obtain the desired effect but, unfortunately, that would also increase the radiation exposure to the rest of the body. The majority of clinicians would require discontinuation of the medication a few days before therapy to overcome these undesirable effects but the question is, is this safe? The issue of when antithyroid medication is warranted is a big question to the clinician. For optimal use of radioiodine therapy, appropriate selection criteria and good clinical judgment concerning pretreatment with antithyroid medication are required. Otherwise, we may put some patients into unnecessary increased risk and added cost. (author)

  10. Post-laryngectomy localization of I-131 at tracheostomy site on a total body scan

    Kirk, G.A.; Schulz, E.E.

    1984-01-01

    A post-thyroidectomy, post-I-131-therapy patient had a laryngectomy and neck dissection for recurrent papillary thyroid carcinoma. A subsequent I-131 total body scan revealed persistent anterior neck activity, which disappeared upon removal of the tracheostomy tube and dressings

  11. Experience in treatment of hyperthyroidism with I-131 diagnosis, patient preparation and therapeutic procedure

    Zhongyun, Pan

    2003-01-01

    Treatment of hyperthyroidism with I-131 diagnosis is being performed after clinical diagnosis of thyrotoxicosis based on clinical manifestations of hypermetabolic state, serumT3 and T4 determination; medical preparation of patients and therapeutic procedure is obtained for better efficacy, relieve symptoms and prevent aggravation of thyrotoxicosis after I-131 treatment

  12. I131-meta-iodobenzylguanidine in the diagnosis and treatment of neural crest tumours

    Hoefnagel, C.A.; Hartog Jager, F.C.A. den; Taal, B.G.; Engelsman, E.; Kraker, J. de; Voute, P.A.

    1988-01-01

    Iodine-131-meta-iodobenzylguanidine (I-131-MIBG) was used for scintigraphic detection and therapy of neural crest tumours. The methodology of both techniques is described. Based upon experience with I-131-MIBG-scintigraphy in 170 patients with neural crest tumours, of whom 46 received multiple therapeutic doses of I-131-MIBG, and upon the cumulative reports in the literature, the role of I-131-MIBG in diagnosis and treatment of each of these diseases is indicated. I-131-MIBG-scintigraphy is one of the most sensitive and specific techniques for the diagnosis, staging and follow-up of phaeochromocytoma and neuroblastoma and I-131-MIBG-therapy may induce remission in a number of these patients. In carcinoid and medullary thyroid carcinoma the diagnostic sensitivity is less; however, once the diagnosis has been made, it is useful to establish that the tumour concentrates I-131-MIBG, to see if the patients at some point in time may be amenable to I-131-MIBG-therapy

  13. Bioaccumulation factor for I-131 in aquatic biota II fish - tilapia (Tilapia Mossambica)

    Garcia, G.F.; Casyao, J.M.; Bautista, E.Rb.

    1982-01-01

    The study was undertaken to provide local values for an essential parameter in the estimation of the dose contribution of I-131 through ingestion of fresh water fish. The result showed that the tilapia used in the experiment did not vary significantly in weight and no definite conclusion can be derived as to the effect of body size to bioaccumulation of I-131. (ELC)

  14. Long-term follow-up study of I-131 therapy for Graves' disease

    Kusakabe, Kiyoko; Nakano, Keiko; Maki, Masako

    1990-01-01

    We have studied the follow-up of thyroid function in the patients with late-onset hypothyroidism and euthyroidism after I-131 therapy of hyperthyroidism. Thirty three patients who did not need the thyroid treatment until ten years after I-131 therapy were classified as euthyroid group. And eleven patients who needed the thyroid supplement of thyroid hormone for late-onset hypothyroidism were classified as hypothyroid group. Patients in both groups who required only a single dose of I-131 for successful treatment of hyperthyroidism had similar age, gland size, 24 hour I-131 uptake, pretreatment serum T 3 uptake level and T 4 concentration, and I-131 treatment dose. Subclinical hypothyroidism occurred in 28.6% of euthyroid group and 66.7% of hypothyroid group four months after I-131 therapy. The levels of T 3 were recovered to higher than normal range at 6 months in euthyroid group, while the levels of T 3 were kept within the normal range in the seventy percent of hypothyroid group. Patients who were still lower in the level of T 3 uptake than normal range at 6 months had a higher incidence of late-onset hypothyroidism. Our observation showed no significant difference in the course of follow-up studies after I-131 therapy between the patients with late-onset hypothyroidism and euthyroidism. (author)

  15. Clinical comparison of I-131 orthoiodohippurate and the kit formulation of Tc-99m mercaptoacetyltriglycine

    Taylor, A. Jr.; Ziffer, J.A.; Steves, A.; Eshima, D.; Delaney, V.B.; Welchel, J.D.

    1989-01-01

    Previous studies in animals and humans have shown that technetium-99m mercaptoacetyltriglycine (MAG3) purified by high-performance liquid chromatography is a renal tubular agent with characteristics similar to those of iodine-131 orthoiodohippurate (OIH). A kit formulation for Tc-99m MAG3 has been developed and compared with I-131 OIH in 17 patients with suspected renal dysfunction and three potential kidney donors. There were no adverse reactions. Tc-99m MAG3 images were of good quality and consistently better than I-131 OIH images. There was no significant difference in the relative renal uptake of Tc-99m MAG3 and I-131 OIH. The 30-minute urinary excretion of Tc-99m MAG3 was 36.4%, versus 40.4% for I-131 OIH. The average plasma clearance of Tc-99m MAG3 (138 mL/min +/- 117) was less than that of I-131 OIH (272 mL/min +/- 205) (P less than .001); however, there was good correlation between the Tc-99m MAG3 and I-131 OIH clearances (r = .87). The volume of distribution of Tc-99m MAG3 (5.96 L +/- 1.94) was less than that of I-131 OIH (9.41 L +/- 3.73) (P less than .001). These characteristics and the advantages of a simple kit formulation should lead to widespread clinical use

  16. The normal and abnormal distribution of the adrenomedullary imaging agent m-[I-131]iodobenzylguanidine (I-131 MIBG) in man: evaluation by scintigraphy

    Nakajo, M.; Shapiro, B.; Copp, J.; Kalff, V.; Gross, M.D.; Sisson, J.C.; Beierwaltes, W.H.

    1983-01-01

    The scintigraphic distribution of m-[ 131 I]iodobenzylguanidine (I- 131 MIBG), an adrenal medullary imaging agent, was studied to determine the patterns of uptake of this agent in man. The normal distribution of I- 131 MIBG includes clear portrayal of the salivary glands, liver, spleen, and urinary bladder. The heart, middle and lower lung zones, and colon were less frequently or less clearly seen. The upper lung zones and kidneys were seldom visualized. The thyroid appeared only in cases of inadequate thyroidal blockade. The ''normal'' adrenal glands were seldom seen and faintly imaged in 2% at 24 hr after injection and in 16% at 48 hr, in patients shown not to have pheochromocytomas, whereas intra-adrenal, extraadrenal, and malignant pheochromocytomas usually appeared as intense focal areas of I- 131 MIBG uptake at 24 through 72 hr

  17. Normal and abnormal distribution of the adrenomedullary imaging agent m-[I-131]iodobenzylguanidine (I-131 MIBG) in man; evaluation by scintigraphy

    Nakajo, M.; Shapiro, B.; Copp, J.; Kalff, V.; Gross, M.D.; Sisson, J.C.; Beierwaltes, W.H.

    1983-01-01

    The scintigraphic distribution of m-[ 131 I]iodobenzylguanidine (I-131 MIBG), an adrenal medullary imaging agent, was studied to determine the patterns of uptake of this agent in man. The normal distribution of I-131 MIBG includes clear portrayal of the salivary glands, liver, spleen, and urinary bladder. The heart, middle and lower lung zones, and colon were less frequently or less clearly seen. The upper lung zones and kidneys were seldom visualized. The thyroid appeared only in cases of inadequate thyroidal blockade. The normal adrenal glands were seldom seen and faintly imaged in 2% at 24 h after injection and in 16% at 48 h, in patients shown not to have pheochromocytomas, whereas intra-adrenal, extra-adrenal, and malignant pheochromocytomas usually appeared as intense focal areas of I-131 MIBG uptake at 24 through 72 h

  18. The present status of I-131 therapy for Graves' hyperthyroidism in Japan. Survey by questionnaire

    Ikekubo, Katsuji; Kusakabe, Kiyoko; Kanaya, Shinichi; Nakada, Kunihiro; Mori, Yutaka

    2003-01-01

    A survey on the I-131 therapy of Graves' hyperthyroidism was undertaken by questionnaire in 1,246 hospitals of Japan. One thousand and ninety seven of them (88.0%) responded to the questionnaire. In this paper, we report the results and analysis of the replies to the questionnaire. In the 121 hospitals (11.03%) of the respondents, I-131 therapy is being performed for Graves' hyperthyroidism. A gradual increase was observed in the annual number of I-131 treated Graves' disease patients during the period of 1998-2001, from 1,740 to 2,484. I-131 treatment was selected mainly for the cases with side effects from antithyroid drug (ATD) therapy, followed by the cases with complication of heart or hepatic diseases, recurrences of hyperthyroidism after surgery, radioiodine treatment, and long-term ATD treatment. The 41% of respondents used I-131 in order to restore euthyroidism, 34% aimed for hyperthyroidism and 41% used the dose properly between the two according to the patients. Administration dosage of I-131 was estimated mainly on the basis of thyroid uptake and volume in 93% of the respondents and 48% calculated the radiation dose by also determining the effective half-life in the thyroid gland. Thyroid size was estimated by scintigram (51%), ultrasonography (US) (33%), CT (22%) and palpation (12%). ATD treatment was used before I-131 administration by 70% of the respondents and 34% after radioiodine therapy. A low-iodine diet was given to the patients for a week (46%) or two weeks (47%) before I-131 administration. However, after treatment only 46% of the respondents continued low-iodine diet for a week. (author)

  19. Software for dosimetry hypothyroid patients treated with I131 pick up and using probe gamma camera

    Jimenez Felstrom, D.; Luis simon, J.; Reyes Garcia, R.; Derecho Torres, P.; Herrador Cordoba, M.

    2015-01-01

    In this communication the process recently implemented in our hospital for pre and post treatment of patients treated with I-131 in benign diseases of the thyroid gland internal dosimetry is described. We have developed a proprietary software that facilitates the process of dosimetry. Through scans Planar or pictures Spect be determines the mass of the gland thyroid. In function of the mass, is calculated by Monte Carlo the media power absorbed by disintegration of the I-131 in said gland endocrine. (Author)

  20. Tc-99m imaging in thyroidectomized differentiated thyroid cancer patients immediately before I-131 treatment.

    Tsai, Chi-Jung; Cheng, Cheng-Yi; Shen, Daniel Hueng-Yuan; Kuo, Shou Jen; Wang, Lien-Yen; Lee, Chiang-Hsuan; Wang, Jhi-Joung; Chang, Ming-Che; Huang, Wen-Sheng

    2016-02-01

    The aim of this study was to evaluate the clinical role of technetium-99m pertechnetate (Tc-99m) imaging in thyroidectomized differentiated thyroid cancer patients immediately before radioiodine-131 (I-131) treatment (Tx). Eighty-six consecutive post-total-thyroidectomy patients (15 men, 71 women; mean age: 46.8 years) with pathologically diagnosed differentiated thyroid cancer were retrospectively studied. Tc-99m imaging immediately before I-131 Tx using both patient-based and lesion-based measurements were analyzed and were further compared with those of post-Tx I-131 whole-body scans. For patients with unequivocally positive Tc-99m uptake, the sensitivity was 77% (patient-based) and 59% (site-based). The positive predictive value (PPV) was 100% for both patient-based and site-based measurements. If equivocal Tc-99m uptake was counted as positive, the sensitivity was 83 and 67%, and the PPV was 100 and 99% for patient-based and site-based measurements, respectively. (a) To increase sensitivity yet maintaining high PPV, equivocal Tc-99m uptake should be considered a positive finding. (b) The nearly 100% PPV of Tc-99m imaging immediately before I-131 Tx for remnant detection suggests that Tc-99m imaging not only serves as an alternative to low-dose I-131 scanning in the low-risk post-thyroidectomy patients but also provides a clue for the subsequent I-131 therapeutic dosage and even for the outcome prediction.

  1. False-positive I-131 scan by contaminated muffler in a patient with thyroid carcinoma

    Seo, Han Kyung; Kim, Min Woo; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Hospital, Chonju (Korea, Republic of)

    2006-02-15

    A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mGi) of an I-131 solution. The anterior image of head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

  2. I131-MIBG in early diagnose of neuroblastoma in symptomatic children

    Saddadi, F.S.; Kargarzadeh, F.K.; Yaghoobi, N.Y.

    2002-01-01

    Aim: Neuroblastoma is the second most common solid tumors in childhood which derivates from neural crest. It is very malignant and almost always patient comes with metastasis. However there are some diagnostic tools to detection of lesion in the early stage of tumor. We decided to have a review with using I-131 MIBG in patients suspected and/or proved to have neuroblastoma. Material and Methods: 300-500 μci I 131 MIBG was injected intravenously in patients (5 patients with age range 4 years old) referred for their bone pain and pelvic mass(detected with anatomical tools). Images were obtained 24 to 72 hours throughout the body with ADAC gamma camera and SPECT was performed in each local abnormal uptake. Each patient has already had a WBBS with TcMDP. Results: All abnormal tracer uptakes were seen in bone scan were revealed clearly in I131 MIBG. However, three to five other abnormal tracer activities were only seen in MIBG scan. The main tumoral lesions were showed perfectly in pelvic,that was not seen in WBBS. With a statistical analysis, I131 MIBG has 94% sensitivity 85-100% specificity, compare to Tc99m-MDP that was 78% and 51% respectively. Conclusions: We found that I131 MIBG is the most useful method to diagnose of patients with neuroblastoma and reproved that it has a competitive role in management, follow-up of these tumors especially in detection of metastasis

  3. A case report of hyperfunctioning metastatic thyroid cancer and rare I-131 avid liver metastasis

    Kunawudhi, Anchisa; Promteangtrong, Chetsadaporn; Chotipanich, Chanisa

    2016-01-01

    Thyroid cancer is usually, relatively hypofunctional; most patients with thyroid cancer are clinically euthyroid. The combination of thyroid cancer and thyrotoxicosis is not common. We herein, report a case of follicular thyroid cancer with hyperfunctioning metastasis in a 43-year-old woman who presented with thyrotoxicosis, a cold right thyroid nodule, and low I-131 uptake at the thyroid bed. An additional total body scan with I-131 revealed a large radioiodine avid osteolytic bone metastasis with soft tissue masses and liver metastasis. The patient received treatment with total thyroidectomy, methimazole, and I-131 at a cumulative dose of 600 mCi along with recombinant human thyroid-stimulating hormone before the first I-131 treatment and palliative radiation. The patient had normal liver function test and experienced a mild degree of bone marrow suppression after I-131. At the 2-year follow-up, the patient was still alive with the progression of bone metastases but was doing well with less severe thyrotoxicosis, good ambulation, and an Eastern Cooperative Oncology Group performance status of 2. Clinicians should be aware of the unusual concurrent presentation of thyrotoxicosis and thyroid cancer, a differential diagnosis in patients with thyrotoxicosis and low or normal radioiodine uptake over the neck and also potential pitfalls during radionuclide treatment

  4. Radioimmunotherapy in refractory b-cell nonhodgkins lymphoma with I-131-labeled chimeric anti cd-20 c2b8 (I-131 rituximab): preliminary result

    Kang, Hye Jin; Park, Yeon Hee; Kim, Sung Eun and others

    2005-01-01

    Recently, the native chimeric human-mouse anti CD-20 antibody IDEC-C2B8 (Rituximab) has been widely applied in NHL. This ongoing phase study was to evaluate whether radioimmunotherapy (RIT) with I-131 rituximab is effective in refractory B-cell NHL. Inclusion criteria were as follows: B-cell NHL with relapsed or refractory to primary standard therapy, measurable disease, adequate hematologic, renal, and hepatic function, informed consent. The rituximab (Mabthera, Roach) was radiolabeled with iodine-131(I-131) using a modified chloramine T method with high radiochemical purity (95%) and preservation of immuno-reactivity. All patients received loading doses of unlabeled rituximab (median, 40 mg: range, 20∼70 mg) immediately prior to administration of therapeutic dose (51.4∼152.2 MBq/kg), and then underwent gamma camera scan. 11 patients were enrolled (4 low-grade B-cell NHL, 7 DLBCL, median age 63 years). Patients had received a median of three prior chemotherapy regimens. The objective response rate was 36.4% (1 CR, 3 PRs). These all responses were observed in low-grade B-cell NHL, except one with DLBCL. Adverse events were primarily hematologic toxicities; the incidence of grade 3/4 neutropenia, thrombocytopenia, and anemia was 27.3%, 45.5%, and 18.2%, respectively. The treatment-related mortality was observed in one patient, who had been previously treated with high-dose chemotherapy plus TBI with autologous stem cell transplantation. RIT with I-131 rituximab seems to be effective tolerable in refractory low-grade B-cell NHL, although modest activity in refractory DLBCL. Further studies to define the efficacy of I-131 rituximab in DLBCL are warranted

  5. Radioimmunotherapy in refractory b-cell nonhodgkins lymphoma with I-131-labeled chimeric anti cd-20 c2b8 (I-131 rituximab): preliminary result

    Kang, Hye Jin; Park, Yeon Hee; Kim, Sung Eun and others [Korea University Medical School, Seoul (Korea, Republic of)

    2005-07-01

    Recently, the native chimeric human-mouse anti CD-20 antibody IDEC-C2B8 (Rituximab) has been widely applied in NHL. This ongoing phase study was to evaluate whether radioimmunotherapy (RIT) with I-131 rituximab is effective in refractory B-cell NHL. Inclusion criteria were as follows: B-cell NHL with relapsed or refractory to primary standard therapy, measurable disease, adequate hematologic, renal, and hepatic function, informed consent. The rituximab (Mabthera, Roach) was radiolabeled with iodine-131(I-131) using a modified chloramine T method with high radiochemical purity (95%) and preservation of immuno-reactivity. All patients received loading doses of unlabeled rituximab (median, 40 mg: range, 20{approx}70 mg) immediately prior to administration of therapeutic dose (51.4{approx}152.2 MBq/kg), and then underwent gamma camera scan. 11 patients were enrolled (4 low-grade B-cell NHL, 7 DLBCL, median age 63 years). Patients had received a median of three prior chemotherapy regimens. The objective response rate was 36.4% (1 CR, 3 PRs). These all responses were observed in low-grade B-cell NHL, except one with DLBCL. Adverse events were primarily hematologic toxicities; the incidence of grade 3/4 neutropenia, thrombocytopenia, and anemia was 27.3%, 45.5%, and 18.2%, respectively. The treatment-related mortality was observed in one patient, who had been previously treated with high-dose chemotherapy plus TBI with autologous stem cell transplantation. RIT with I-131 rituximab seems to be effective tolerable in refractory low-grade B-cell NHL, although modest activity in refractory DLBCL. Further studies to define the efficacy of I-131 rituximab in DLBCL are warranted.

  6. Internal dosimetry for the radiological protection of the patient in the therapy with I-131; Dosimetria interna para la proteccion radiologica del paciente en la terapia con I-131

    Deluca, G.M.; Rojo, A.M. [Autoridad Regulatoria Nuclear, Av. Del Libertador 8250 (C1429BNP), Buenos Aires (Argentina)]. e-mail: gdeluca@cae.arn.gov.ar

    2006-07-01

    In the patients with differentiated thyroid cancer (CADIT) subjected to therapy with radiopharmaceuticals should be considered the possible risk of sharp depression of the bone marrow like consequence of the intolerance to the quantity of administered activity. The manifestation of the myelotoxicity can limit in a substantial way the future treatments and to deteriorate the predict of resolution of the illness. In this work it shows the physical-mathematical mark of a methodology for the estimated absorbed dose in bone marrow based in the MIRD scheme whose objective is to protect the one patient of the noxious and undesirable effects of the internal radiotherapy in organs that are not target of the same one. The formalism incorporates specific information of the patient and also peculiar characteristics of the internal therapy in patient with CADIT. The considerations are the following ones: (1) the main organ to protect is the bone marrow: (2) the accumulated activity, in bone marrow, it is obtained starting from measurements in blood: (3) the used isotope almost exclusively in this type of therapies is the {sup 131}I; (4) it is used as radiopharmaceutical at the {sup 131}INa that it is characterized to be a simple, inorganic and small molecule: (5) the statistical incidence of the CADIT is bigger in women than in men. It is explained for that it was selected the formalism that is presented, the principles on which it is sustained which are their reaches and their limitations. They are also presented future innovations that can be implemented to effects of improving the estimates. The work is framed inside the thematic of the medical applications of open radioactive sources and it constitutes a contribution to the invigoration of the internal therapy with radiopharmaceuticals. This is due to that the methodology of dose estimation presented supplements with a theoretical biophysics base the protocols of empiric prescription broadly used in this practice. For these reasons, the dosimetric information obtained, adjusted to each concrete case, it contributes to improve the radiological protection of the patient. (Author)

  7. Evaluation of systematic I-131 thyroid measurements for nuclear medicine workers

    Puscalau, M.A.

    2002-01-01

    In Nuclear Medicine, I-131 is used intensively for the diagnosis and for the treatment of the different severities maladies of the thyroid. This radionuclide generates an important internal contamination to the patients, because of its oral administration, and, also, through inhalation, to the workers involved in the radiopharmaceuticals production , to the nursing staff and to the physicians that care and treat the patients in the hospitals. The paper presents the data obtained by systematically thyroid monitoring of the physicians and nurses from the Endocrinology Hospital, that are contaminated by I-131 inhalation because of their permanent relation with the patients treated with 3.7 MBq I-131 for investigation and with activities in the range 1100 MBq - 4000 MBq for therapy. The measurements were carried out with our Body Counter equipped with a NaI(Tl) scintillation detector, 50 mm thickness and 40mm diameter. Values of the estimated committed equivalent doses are, also, reported

  8. Testicular impact of the treatment with I-131 in patients with differentiated thyroid carcinoma

    Chebel, G.; Gutierrez, S.; Fadel, A.; Suarez, S.; Levalle, O.

    2007-01-01

    Young patients carriers differentiated thyroid carcinoma (DTC) are treated with high doses of I-131 for much of his life with very good prognosis and projects with paternity. However, there is scarce information on the effect of radioiodine on the male gonad and their future fertility. This therapy may compromise on a temporary and / or definitively the role of the germinal cells. The testicular irradiation depends on the blood flow, the dose of I-131 administered and of the presence or absence of metastasis pelvic near to the gonads. A single dose of 100 mCi of I-131 throws an absorbed dose at gonadal level of 50-150 cGy. It has been reported that absorbed doses of 50 cGy can produce transitory decrease spermatogenesis and higher doses can also affect the function of the Leydig cells [es

  9. Calculation of the activity incorporated in the therapy with I 131

    Chica, L.G.; Puerta, J.A.

    1998-01-01

    By means of the product S(T--S). A-s-(T-e-). the absorbed dose to thyroid delivered by I-131 incorporated is calculated. Where S(T--S) is the absorbed dose in the thyroid per nuclear transformations (tn.) of I-131 localized in the thyroid and as a potential function of the mass is expressed. A-s-(T-e-) is the number of tn. of I-131 in the thyroid since the moment of the incorporation until the time T-e- (the effective middle time); to find A-s-(T-e-) to normal as different pathological conditions, the metabolic model of the iodo proposed by the ICRP is used. Of the expression of the doses, the incorporated activity, I-o- is obtained

  10. Estimation of foetal brain dose from I-131 in the foetal thyroid

    O'Hare, N.J.; Murphy, D.; Malone, J.F.; Gilligan, P.

    1997-01-01

    The ingestion of I-131 by pregnant women can have consequences for the developing foetus, in particular brain function. As the foetal thyroid accumulates iodine from the twelfth week of gestation onwards, the determination of foetal brain dose resulting from such I-131 accumulation is essential. Normal dosimetric methods fail to treat the case of the foetus. Using an approximation method based on the MIRD approach, a foetal dose estimation scheme is developed to allow the determination of foetal brain dose from foetal thyroid irradiation. Dose values are obtained for the foetus based on the maternal intake of I-131. It was found that the choice of biokinetic model for the mother/foetus has a large impact on the determined dose estimate. (author)

  11. The therapeutic use of I-131 meta-iodobenzylguanidine (MIBG) in neuroblastoma

    Hartmann, O.; Lumbroso, J.D.; Lemerle, J.; Schlumberger, M.; Parmentier, C.; Ricard, M.; Aubert, B.; Coornaert, S.; Merlin, L.

    1988-01-01

    Despite the use of intensified conventional chemotherapy the complete response rate of advanced neuroblastoma remains low. The use of high-dose chemo-radiotherapy followed by bone marrow transplantation (BMT) improved the duration of disease free survival but, even after these high-dose regimens the relapse rate remains high. Metaiodobenzylguanidine (MIBG) labelled with I-131 or I-123 can be used for scintigraphic imaging of neuroblastoma. In order to evaluate the therapeutic role of I-131-MIBG in the treatment of neuroblastoma patients, a phase II study was performed in 12 patients. Results are presented in this paper

  12. Recurrence rates following I-131 therapy of differentiated thyroid carcinoma: results of meta-analysis

    Obaldo, J.M.

    1990-01-01

    To examine the efficacy of I-131 therapy in decreasing recurrence rates after surgery for differentiated thyroid carcinoma, a research tool called meta-analysis was used. Data were pooled from five published studies which evaluated recurrences following at least sub-total thyroidectomy with or without I-131 ablation of remnants. Of 1332 patients managed surgically only 202 (15%) developed recurrences compared to 36 of 339 (11%) treated with radioiodine. This difference was statistically significant at p<.05. When a separate analysis of only those studies which directly compared the two modes of management was conducted, recurrence rates for patients treated by surgery alone was higher at 18% (185 of 1034) compared with those who had subsequent I-131 therapy with a rate of 9% (27 of 297). This difference was again significant at p <.001. This meta-analysis strongly suggests that the use of I-131 for ablation of post-surgical thyroid remnants significantly reduces recurrence rates in patients with differentiated thyroid carcinoma. (Auth.). 34 refs., 1 tab.; 1 fig

  13. Renal I-131-hippurate clearance overestimates true renal blood flow in the instrumented conscious dog

    Visscher, CA; DeZeeuw, D; Navis, G; VanZanten, AK; DeJong, PE; Huisman, RM

    We evaluated renal I-131-hippurate clearance (ERPF(hip)) as a measure of renal blood flow (RBF) in chronically instrumented conscious dogs. When adjusted for renal hippurate extraction (E(hip), 0.77 +/- 0.01) and hematocrit (Hct, 39.7 +/- 1%), calculated RBF(hip) (656 +/- 37 ml/min) markedly

  14. 76 FR 81517 - Agency Information Collection Activities: Form I-131, Revision of an Existing Information...

    2011-12-28

    ... information collection. (2) Title of the Form/Collection: Application for Travel Document. (3) Agency form... DEPARTMENT OF HOMELAND SECURITY U.S. Citizenship and Immigration Services Agency Information...-Day Notice of Information Collection Under Review: Form I- 131, Application for Travel Document. The...

  15. 77 FR 15787 - Agency Information Collection Activities: Form I-131, Revision of an Existing Information...

    2012-03-16

    ... the Form/Collection: Application for Travel Document. (3) Agency Form Number, if any, and the... DEPARTMENT OF HOMELAND SECURITY U.S. Citizenship and Immigration Services Agency Information...-Day Notice of Information Collection Under Review: Form I- 131, Application for Travel Document. The...

  16. Control system of liquid effluents generated in treatment with I-131; Sistema de control de efluentes liquidos generados en el tratamiento con I-131

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R., E-mail: teodoro.garcia@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  17. Evaluation of results of more than 20 years treating hyperthyroidism by I-131

    Phan, S.A.; Mai, T.K.; Tran, D.H.

    2001-01-01

    The authors have summarized their works of more than 20 years using I-131 for treatment and close observation of 723 patients with hyperthyroidism in 1000 ones in the Nuclear Medicine Department, Bach Mai University Hospital in Hanoi to collect data and draw experience for the report. Patient selection for the treatment is based on clinical features and laboratory tests results by the Nuclear Medicine Department such as thyroid uptake, scintigraphy and RIA determinations of thyroid hormones. I-131 dose is determined in compliance with a prevailing formula. The average dose is 6.2 ± 1.1 mCi (that is 233.1 ± 40.7 MBq). The average number of times is 1.3 time for one patient. The results are as follows: Euthyroid status after 4- year following- up from date of I-131 dose administration: 72.3%; Persistent or recurrent hyperthyroidism: 20.0%; Hypothyroid complications: appear 4 to 12 months after date of I-131 administration: 3.0%; appear 4 years after date of I-131 administration: 7.7%; appear 6 years after date of I-131 administration. 14.0%; so the cumulative hypothyroid rate is 2.3% per year. No occurrence of other serious complications by all the observed patients. This is therefore a safe, efficient treatment method to be applied on a large scale including adolescents and children. However, much more study has still to be made on the dose due to high rate of recurrence of the therapeutic method although the hypothyroid complications cases are not serious. Hyperthyroidism is a common health problem in Viet Nam. Previously, only anti-thyroid drugs and surgery were used. Use of I-131 was firstly introduced to Viet Nam in the Nuclear Medicine Department in Bach Mai in 1974 and afterwards applied larger nationwide. Initial therapeutic results have been published in national medical magazines. This is a general study aiming at analyzing the way to carry out the work and get experience and recommendation from gained results for further work in the future. (author)

  18. Is it safe to treat hyperthyroid patients with I-131 without fear of thyroid storm?

    Vijayakumar, V.; Nusynowitz, M.L.; Ali, S.

    2006-01-01

    Thyroid storm is extremely rare. However, hyperthyroid patients with severe thyrotoxicosis are frequently not treated immediately with I-131 for fear of thyroid storm but are placed on thiouracil drugs for varying periods of time. We demonstrate herein that it is safe to treat these patients with I-131, without pretreatment with thiouracil drugs, provided they do not have complicating intercurrent disease. Our definition of severe hyperthyroidism includes marked signs and symptoms of thyrotoxicosis, suppressed thyroid stimulating hormone (TSH), markedly elevated free T4 and/or free T3 and elevated radioactive iodine uptake (RAIU) (>30%) at 4 or 24 hours. Our diagnostic criteria for thyroid storm include two or more findings of fever (>38 deg C, 100 deg F), severe tachycardia, high pulse pressure, agitation with tremors, flushing, sweating, heart failure, nausea, vomiting, diarrhea, jaundice associated with high free T4 and/or free T3. Patients were selected retrospectively for the period between August 2003 and December 2004. One hundred and twenty-two patient visits were identified. These patients were treated with 370-740 MBq (10-20 mCi) of I-131 and were evaluated for any evidence of thyroid storm. Most of the patients were placed on beta blocker drugs at the time of initial I-131 therapy; these were continued for at least two months, when the first follow-up visit occurred. At the time of I-131 therapy, it is our policy to educate the patients to seek immediate medical attention for exacerbation of symptoms of thyrotoxicosis. Not one of these patients developed thyroid storm. A subset of 25% of these cases with higher potential for thyroid storm (RAIU more than 65%, very marked signs and symptoms, and very markedly elevated free T4 and/or free T3) also tolerated the I-131 therapy well with marked clinical improvement and no exacerbation of the thyrotoxic state. It is safe to administer I-131 to patients who are severely hyperthyroid without fear of thyroid

  19. The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery

    Kim, Dong Ik; Suh, Jung Ho; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang; Park, Chan Il; Kim, Byung Ro

    1989-01-01

    Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. It was also to verify the safety of this technique in clinical applications. Radioactive iodized oil was obtained by simple exchange method . 518 ± 19 MBq(14 mCi, about 1 mCi/kg body weight) of I-131 Lipiodol was injected intraarterially in 12 dogs as a experimental group. Serial count rates over the livers under gamma camera were measured, and then it was compared with quantitative analysis of radioactivities distributed in liver, lung, spleen, kidney, thyroid, bile and circulating blood using dose calibrator after sacrifice at various time intervals. Cumulative radiation doses were calculated by Quimby method. The effect of I-131 lipiodol on hepatic function were analysed by serial liver function tests after intrahepatic injection of I-131 Lipiodol and compared with preinjection values. Liver tissue obtained after sacrifice were stained with hematoxylin-eosin, Oil red-O, and also election microscopic examinations were performed. The results were summarized as follows; 1

  20. I-131 therapy for thyroid diseases: Doses, new regulations and patient advice

    Amaral, H.; Michaud, P.

    2001-01-01

    I-131 therapy has been widely used in the past 50 years. Its main applications are hyperthyroidism and functioning thyroid cancer. The indications, doses, regulations, precautions and guidelines differ in various centers. The following are recommended: 1. I-131 should be indicated in agreement of the endocrinologist and the nuclear physician with the patient consent; 2. Pre-treatment I-131 thyroid uptake must be performed; 3. The only contraindication for treatment is pregnancy, in children it might be used with caution; 4. For thyrotoxicosis both a calculated or an ablative dose (555 MBq) criteria are acceptable In this case secondary hypothyroidism must be considered an objective rather than a complication; 5. In uninodular toxic goiter a 1110 MBq dose is recommended; 6. Iodine free diet is indicated only for cancer patients; 7. Propylthiouracil (PTU) must be discontinued 5 days before treatment, it should be reinitiated 5 days later; 8. Prophylactic use of corticoid in Graves' disease still require more clinical data to support its use; 9. In treatment failure, wait six months for a new dose; 10. In intrathyroid cancer disease an ablative dose of 3700 MBq should be administered 4 weeks post-thyroidectomy or with a TSH level above 30 μUI/mL; 11. A whole body scan should be done one week later; 12. Follow-up whole body scan should be used only if there is clinical suspicion of metastasis. Thyroid hormone replacement must be discontinued for 30 days or with TSH value above 30 I/mL. For follow-up scan 185 MBq of I-131 are recommended to ovoid thyroid tissue stunning; 13. For metastases, 5700 to 7400 MBq dose is recommended if there are cervical lymphatic nodes or distant metastases. We recommended to adopt the criteria proposed by the United States Nuclear Regulatory Commission (NRC) published as 10 CFR 35.75 and the Regulatory Guide 8.39 for patients release after I-131 administration. (author)

  1. Efficiency of radioiodine therapy with a fix dose of I-131 in toxic thyroid adenoma

    Petrovski, Z

    2004-01-01

    Purpose: The aim of this study was to estimate the results obtained using a fix dose of I-131 in the treatment of the solitary toxic thyroid adenoma. Material and Methods: We have performed radioiodine therapy m 64 patients, 49 female (50+ 1 7 yrs) and 15 male (43+-15 yrs) with solitary toxic thyroid adenoma. 45 patients received fix dose I-131 of 850 MBq, while 19 patients were treated with calculated (MBq/gr) dose 555-1100 MBq Previously 39(64%) patients were clinically hyperthyreotic and received thyreostatic meditication which were interruptecf one week before the administration of I-131. Those patients who were euthyreotic, TSH was suppressed(<0.25 MU/m1). 61(95.3%) patients received a single dose, while 3(4, 7%) patients needed two doses. Resulting thyroid matabolism and volume of nodules were evaluated 6-48 months after treatment. Results: From 45 radioiodine treated patients with fix dose 6(9, 8%) became hypothyroidism, 36(85, 3%) euthyroidism and 3(4, 9%) recurrent hyperthyroidism, in comparison with 19 treated patients with calculated I-131 dose: 2(10, 5%) hypothyroidism, 16(84, 3%) euthyroidism and 1(5, 2%) recurrent hyperthyroidism. The size of the nodules became unpalpable m 17(26, 2%), decreased evidently in 33(52, 5%) and remained unchanged in 14(21, 3%) of the treated patients. Conclusion: A fix dose of I-131 is simple, safe and efficient in the treatment of solitary toxic thyroid adenoma. There was not significant different in incidence of late follow-up results of hypothyroidism and recurrent hyperthyroidism between fix dose and calculated MBq/gr dose. (authors)

  2. Radiation Dose-rate Reduction Pattern in Well-differentiated Thyroid Cancer Treated with I-131.

    Khan, Shahbaz Ahmad; Khan, Muhammad Saqib; Arif, Muhammad; Durr-e-Sabih; Rahim, Muhammad Kashif; Ahmad, Israr

    2015-07-01

    To determine the patterns of dose rate reduction in single and multiple radioiodine (I-131) therapies in cases of well differentiated thyroid cancer patients. Analytical series. Department of Nuclear Medicine and Radiation Physics, Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), Multan, Pakistan, from December 2006 to December 2013. Ninety three patients (167 therapies) with well differentiated thyroid cancer treated with different doses of I-131 as an in-patient were inducted. Fifty four patients were given only single I-131 therapy dose ranging from 70 mCi (2590 MBq) to 150 mCi (5550 MBq). Thirty nine patients were treated with multiple I-131 radioisotope therapy doses ranging from 80 mCi (2960 MBq) to 250 mCi (9250 MBq). T-test was applied on the sample data showed statistically significant difference between the two groups with p-value (p < 0.01) less than 0.05 taken as significant. There were 68 females and 25 males with an age range of 15 to 80 years. Mean age of the patients were 36 years. Among the 93 cases of first time Radio Active Iodine (RAI) therapy, 59 cases (63%) were discharged after 48 hours. Among 39 patients who received RAI therapy second time or more, most were discharged earlier after achieving acceptable discharge dose rate i.e 25 µSv/hour; 2 out of 39 (5%) were discharged after 48 hours. In 58% patients, given single I-131 therapy dose, majority of these were discharged after 48 hours without any major complications. For well differentiated thyroid cancer patients, rapid dose rate reduction is seen in patients receiving second or subsequent radioiodine (RAI) therapy, as compared to first time receiving RAI therapy.

  3. Radioiodine (I-131) treatment for uncomplicated hyperthyroidism: An assessment of optimal dose and cost-effectiveness

    Paul, A.K.; Rahman, H.A.; Jahan, N.

    2002-01-01

    Aim: Radioiodine (I-131) is increasingly being considered for the treatment of hyperthyroidism but there is no general agreement for the initial dose. To determine the cost-effectiveness and optimal dose of I-131 to cure disease, we prospectively studied the outcome of radioiodine therapy of 423 patients. Material and Methods: Any of the fixed doses of 6, 8, 10, 12 or 15 mCi of I-131 was administered to the patients relating to thyroid gland size. The individual was excluded from this study who had multinodular goitre and autonomous toxic nodule. Patients were classified as cured if the clinical and biochemical status was either euthyroid or hypothyroid at one year without further treatment by antithyroid drugs or radioiodine. The costs were assessed by analyzing the total cost of care including office visit, laboratory testing, radioiodine treatment, average conveyance and income loss of patient and attendant and thyroxine replacement for a period of 2 years from the day of I-131 administration. Results: The results showed a progressive increase of cure rate from the doses of 6, 8 and 10 mCi by 67%, 76.5% and 85.7% respectively but the cure rate for the doses of 12 and 15 mCi was 87.9% and 88.8% respectively. Cure was directly related to the dose between 6 and 10 mCi but at higher doses the cure rate was increased marginally at the expense of increased total body radiation. There was little variation in total costs, but was higher for low dose-therapy and the cost proportion between the 6 mCi regimen and 10 mCi regimen was 1.04:1. Conclusion: We could conclude that an initial 10 mCi of I-131 may be the optimal dose for curing hyperthyroidism and will also limit the total costs

  4. Preparation of a radioactive boron compound (B-I-131-lipiodol) for neutron capture therapy of hepatoma

    Chou, F.I.; Chung, H.P.; Chung, R.J.; Wen, H.W.; Wei, Y.Y.; Kai, J.J.; Lui, W.Y.; Chi, C.W.

    2000-01-01

    In our research, a radioactive boron compound, B-I-131-lipiodol, that can be selectively retained in hepatoma cells was prepared. Combining the effect of α particles produced by boron neutron capture reaction with the β particles released by radionuclides in the radioactive boron compounds will produce a synergistic killing effect on cancer cells. Human hepatoma HepG2 cell cultures were used to examine the stability and the intracellular distribution of the radioactive boron drug. Microscopes were used to examine the interaction and retention of B-I-131-lipiodol globules in the individual hepatoma cell. Moreover, ICP-AES and NaI scintillation counter were performed to determine boron concentrations and I-131 radioactivity, respectively. Results showed that B-I-131-lipiodol with a boron concentration and a specific radioactivity ranged from 500-2000 ppm and 0.05-10 mCi/mL respectively was stably retained in serum. The radiochemical purity of B-I-131-lipiodol was 98%. After supplement with a medium containing B-I-131-lipiodol, the HepG2 cells had intracellular B-I-131-lipiodol globules in the cytoplasm as seen by inverted light microscope, the I-131 and boron can be stably retained in HepG2 cells. (author)

  5. Differentiated Thyroid Carcinoma After I-131-MIBG Treatment for Neuroblastoma During Childhood: Description of the First Two Cases

    van Santen, Hanneke M.; Tytgat, Godelieve A. M.; van de Wetering, Marianne D.; van Eck-Smit, Berthe L. F.; Hopman, Saskia M. J.; van der Steeg, Alida F.; Nieveen van Dijkum, Els J. M.; van Trotsenburg, A. S. Paul

    2012-01-01

    Background: It is well known that the thyroid gland is sensitive to the damaging effects of irradiation (X-radiation or I-131(-)). For this reason, during exposure to I-131-metaiodobenzylguanidine (MIBG) in children with neuroblastoma (NBL), the thyroid gland is protected against radiation damage by

  6. Indication of doxorubicin cardiotoxicity by impairment of pIPPA I 131 utilization

    Lenzhofer, R.; Dudczak, R.

    1986-01-01

    The present study was designed to evaluate if doxorubicin (D) can impair myocardial fatty acid utilization. To this end we studied the myocardial utilization of pIPPA I 131 in untreated (Co, n=6) and D (20 mg/kg intraperitoneal) treated rats. D was given 24 h (24 D, n=6) and 48 hours (48 D, n=6) before tracer administration. One min after i.v. pIPPA I 131 (50 μCi) injection, the hearts were rapidly removed, frozen in liquid nitrogen, weighed, and counted. Following lipid extraction of homogenized heart extracts 131 I radioactivity distribution was analyzed by thin-layer chromatographity (TLC). In additional rat experiments, high energy phosphates (12 rats/group) and carnitine (20 rats/group) were determined enzymatically in heart extracts. The mean pIPPA uptake in rat heart (%dose/g) was 2.49 in Co, 1.74 in 24 D, and 2.36 in 48 D rats. Usually five peaks were separated by TLC, that with a mean Rf value of 0.92 corresponding to pIPPA I 131, the remaining four representing catabolites of pIPPA metabolism. The mean relative amount of unmetabolized pIPPA I 131 as compared to the sum of pIPPA I 131 catabolites was less in Co than in 24 D or 48 D rats (P<0.05) (anti x: 46.5% vs 72.4% vs 59.4%, respectively). The mean carnitine content of H extracts was higher in Co (0.55 μM/g) than in D treated rats (24 D, 0.42 μM/g; 48 D, 0.46 μM/g) (P<0.05). The total amount of higher energy phosphates was not different between the groups. However the mean ATP/AMP ratio was higher in Co (35.9) than in 24 D (22.3) or 48 D (27.1) rats (P<0.05). We conclude that D therapy is accompanied by a partial reversible impairment in myocardial pIPPA utilization, possibly mediated by carnitine deficiency. Thus, pIPPA I 131 might be useful in patients on D therapy to evaluate eventual D-induced effects on myocardial fatty acid utilization. (orig.)

  7. Development of gamma-photon/Cerenkov-light hybrid system for simultaneous imaging of I-131 radionuclide

    Yamamoto, Seiichi; Suzuki, Mayumi; Kato, Katsuhiko [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan); Ogata, Yoshimune [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan)

    2016-09-11

    Although iodine 131 (I-131) is used for radionuclide therapy, high resolution images are difficult to obtain with conventional gamma cameras because of the high energy of I-131 gamma photons (364 keV). Cerenkov-light imaging is a possible method for beta emitting radionuclides, and I-131 (606 MeV maximum beta energy) is a candidate to obtain high resolution images. We developed a high energy gamma camera system for I-131 radionuclide and combined it with a Cerenkov-light imaging system to form a gamma-photon/Cerenkov-light hybrid imaging system to compare the simultaneously measured images of these two modalities. The high energy gamma imaging detector used 0.85-mm×0.85-mm×10-mm thick GAGG scintillator pixels arranged in a 44×44 matrix with a 0.1-mm thick reflector and optical coupled to a Hamamatsu 2 in. square position sensitive photomultiplier tube (PSPMT: H12700 MOD). The gamma imaging detector was encased in a 2 cm thick tungsten shield, and a pinhole collimator was mounted on its top to form a gamma camera system. The Cerenkov-light imaging system was made of a high sensitivity cooled CCD camera. The Cerenkov-light imaging system was combined with the gamma camera using optical mirrors to image the same area of the subject. With this configuration, we simultaneously imaged the gamma photons and the Cerenkov-light from I-131 in the subjects. The spatial resolution and sensitivity of the gamma camera system for I-131 were respectively ~3 mm FWHM and ~10 cps/MBq for the high sensitivity collimator at 10 cm from the collimator surface. The spatial resolution of the Cerenkov-light imaging system was 0.64 mm FWHM at 10 cm from the system surface. Thyroid phantom and rat images were successfully obtained with the developed gamma-photon/Cerenkov-light hybrid imaging system, allowing direct comparison of these two modalities. Our developed gamma-photon/Cerenkov-light hybrid imaging system will be useful to evaluate the advantages and disadvantages of these two

  8. Initial radioiodine remnant ablation success rates compared by diagnostic scan methods: I123 versus I131

    Choi, W.; Choi, E.; Yoo, I.; Kim, S.; Han, E.; Lee, S.; Lee, W.

    2015-01-01

    Full text of publication follows. Objective: to see if diagnostic whole body scan (DxWBS) performed with I-131 prior diminishes the success rate of initial radioiodine remnant ablation (RRA) compared to I-123 DxWBS in differentiated thyroid cancer patients. Material and methods: consecutive thyroid cancer patients who received total thyroidectomy for differentiated thyroid cancer and then high dose RRA (either 100 mCi or 150 mCi) within 6 months were included. DxWBSs were performed with I-123 or with I-131. Prior to the DxWBSs, all patients followed strict low iodine diet for 2 weeks and withdrew hormone to stimulate TSH above 30 mIU/l. Patients with extra-thyroidal extension of tumor, lymph node metastasis, or distant metastasis were excluded. The initial RRA was defined as successful if the next DxWBS done 6 months to 1 year later was negative and stimulated thyroglobulin level was below 2 ng/ml. Results: of 71 patients who had I-123 DxWBSs, 31 patients went on to receive RRA with 100 mCi and 40 patients received 150 mCi. Of 73 patients who had I-131 DxWBSs, 66 received 100 mCi and 7 patients received 150 mCi. The overall success rate was 79% for patients who had I-123 DxWBS prior to RRA (68% for 100 mCi and 86% for 150 mCi), and 68% for patient who had I-131 DxWBSs (68% for 100 mCi and 71% for 150 mCi). Conclusion: for patients who received 100 mCi, the RRA success rate was the same for I-123 DxWBS and I-131 DxWBS. For patients treated with 150 mCi, the success rate may be lower in patients who receive RRA following DxWBS with I-131 compared to DxWBS with I-123. (authors)

  9. Comparison of F-18 FDG PET and I-131 whole body scan in diagnosis of suspicious metastatic thyroid carcinoma

    Seok, Ju Won; Chung, June Key

    2005-01-01

    There are several reports about the usefulness of F-18 FDG PET in thyroid cancer. The aim of this study was to evaluate the effectiveness of F-18 FDG PET and I-131 whole body scan in suspicious metastatic thyroid cancer. There were 46 patients (11 men, 35 women; age range, 18-74yr; mean age, 47.3yr) with suspicious metastatic thyroid cancer after total thyroidectomy who performed FDG PET and I-131 scan. The interval of FDG PET and I-131 scan was within 6 months. An overall clinical evaluation was performed including cytology, thyroglobulin level, sonography, MRI and CT. Metastatic regions were divided into four areas: neck, mediastinum, lung and bone. Among 46 patients, the number of patients, metastatic lesions were detected, totaled 36 (78.3%). Twenty-nine patients (63.0%) were detected by FDG PET and 18 patients (39.1%) were detected by I-131 scan. Twenty-one patients were detected in neck by two methods. Nineteen patients (90.5%) were detected by FDG PET and 7 patients (33.3%) were detected by I-131 scan. Eighteen patients were detected in mediastinum by two methods. Ten patients (55.5%) were detected by FDG PET and 10 patients (55.5%) were detected by I-131 scan. Ten patients were detected in lung by two methods. Nine patients (90.0%) were detected by FDG PET and 3 patients (30.0%) were detected by I-131 scan. Three patients were detected in bone by two methods. Three patients (100%) were detected by FDG PET and 0 patients (0%) were detected by I-131 scan. These data indicate that for detecting metastatic lesions, F-18 FDG PET and I-131 whole body scan may provide complementary information. Thus, the combination of FDG PET and I-131 scan is the method of choice for detecting suspicious metastatic thyroid cancer after total thyroidectomy

  10. Diagnostic I-131 scintigraphy in patients with differentiated thyroid cancer. No additional value of higher scan dose

    Phan, T.T.H.; Tol, K.M. van; Links, T.P.; Piers, D.A.; Vries, E.G.E. de; Dullaart, R.P.F.; Jager, P.L.

    2004-01-01

    After initial treatment with total thyroidectomy and radio iodine ablation, most follow-up protocols for patients with differentiated thyroid carcinoma contain cyclic diagnostic I-131 imaging and serum thyroglobulin (Tg) measurements. The applied diagnostic I-131 doses vary between 37 and 370 MBq. The aim of this study was to determine the yield of a diagnostic scan with 370 MBq I-131 in patients with a negative diagnostic scan with 74 MBq I-131. Retrospective evaluation of 158 patients who received a high-dose diagnostic scan with 370 MBq I-131 because of a negative low-dose diagnostic scan with 74 MBq I-131. Special attention was paid to the patients with positive high-dose diagnostic scanning and undetectable serum Tg levels after thyroid hormone withdrawal. In 127 (80%) of patients the 370 MBq I-131 scan was negative, just like the preceding low-dose scan. In 31 (20%) of patients abnormal uptake was present on the 370 MBq diagnostic scan. In 19 of these 31 patients serum Tg was undetectable. In 15/19 the high-dose diagnostic scan proved either false positive or demonstrated clinically irrelevant minor ablation rests. In only four patients (2.5%) did the high-dose diagnostic scans reveal possibly relevant uptake caused by residual differentiated thyroid cancer. In 98% of patients a 370 MBq dose of I-131 for diagnostic whole-body scintigraphy (WBS) had no additional value. The combination of a low-dose diagnostic I-131 scan using only 74 MBq combined with a serum Tg level measurement proved sufficient for correct clinical decision making regarding whether the patient requires additional I-131 therapy. (authors)

  11. Measurement Of I-131 In Air Using A Portable Gamma Spectrometer

    Bunawas; Dadong Iskandar; Wahyudi; U, Wiwik

    2000-01-01

    Aerosol contamination of I-131, radioactive emitting gamma radiation, can be directly measured by using a portable gamma spectrometer which used GC2020 Canberra HPGe detector. Assuming constant concentration of I-131 in the infinite space of semi spherical, calibration factor, and detection limits determined using standard CH 3 I gas. The results showed that the detection limits for 1 hour counting period was 3.06 Bq/m exp.3 for confidence level of 95% (2σ). Field measurements are conducted on several rooms with uncertainties variation between 0.34 and 60.11% compare with true values. Qualitative discussion of the factors contributing to the uncertainty in the in situ result is included

  12. I-131 Dose Response for Incident Thyroid Cancers in Ukraine Related to the Chornobyl Accident

    Brenner, Alina V.; Tronko, Mykola D.; Hatch, Maureen; Bogdanova, Tetyana I.; Oliynik, Valery A.; Lubin, Jay H.; Zablotska, Lydia B.; Tereschenko, Valery P.; McConnell, Robert J.; Zamotaeva, Galina A.; O?Kane, Patrick; Bouville, Andre C.; Chaykovskaya, Ludmila V.; Greenebaum, Ellen; Paster, Ihor P.

    2011-01-01

    Background: Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case?control studies, and studies of prevalent cancers. Objective: To address this limitation, we evaluated the dose?response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. Methods: The cohort consists of individuals < 18 years of age on 26 April 1986 who ...

  13. A feasibility study of thyroid cancer among patients treated with I-131

    Anderson, T.W.

    1984-04-01

    This study examined the feasibility of conducting a Canada-wide follow-up study of persons receiving I-131 before 1970, to see if current estimates of induction of thyroid cancer are well founded. It is concluded that such a study is not feasible due to the widespread destruction of old records, and the limited quantity of personal identifying information on those records that do still exist

  14. Radiation protection recommendations for I-131 thyrotoxicosis, thyroid cancer and phaeochromocytoma patients

    Woodings, S.

    2004-01-01

    Iodine-131 patients pose a radiation risk to their family members, carers and colleagues. Doses from thyrotoxicosis and thyroid cancer patients undergoing standard treatments have been well characterised in the literature. However the resulting precautions cannot be easily adapted to circumstances where the patient has an unusual affliction, or an atypical family or occupational environment. In this study, a model for calculating dose from an I-131 patient is derived from first principles. The model is combined with existing results from the literature to determine a distance weighting factor between patients and family members. This technique reduces the uncertainty in the dose calculations by removing the need to guess the unknown patterns of close contact, a problem common to all previous dose calculation techniques. Data is presented for four unusual I-131 treatments; a child thyroid cancer patient, two thyroid cancer dialysis patients and a phaeochromocytoma patient. The model is used to calculate appropriate periods of restricted contact for these patients. The recommendations provide a useful guide for future unusual I-131 treatments. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  15. I-131 attraction by thyroid during first hours following its oral administration

    Franquiz, J.M.; Cardenas, R.; Blanco, J.; Garcia, M.

    1982-01-01

    From radioisotopic investigations used to study thyroid function, that of I-131 attraction results to be one of the most known and used in medical practice. In the authors' laboratory measurement of I-131 activity upon the gland has been for long adopted at 24 hours after administration; however, current needs compel to look for an early time (within the first six hours) for measuring it. In the paper results of I-131 attraction by thyroid in a group with more than 200 patients at 2,4 and 24 hours following its administration are presented in order to assess a 24 hours attraction representativeness by an early attraction. Results demonstrate early attraction is representative of an attraction at 24 hours and with the same diagnostic usefulness. Normal and doubtful ranks for attraction in our medium are determined at 2 and 6 hours, being adopted as proceeding for those cases whose value should be found within doubtful rank, a measurement at 24 hours in order to determine functional condition of the gland. (author)

  16. Chemical Process for Treatment of Tellurium and Chromium Liquid Waste from I-131 Radioisotope Production

    Zainus-Salimin; Gunandjar; Dedy-Harsono; Hendro; Sugeng-Purnomo; Mohammad-Faruq; Zulfakhri

    2000-01-01

    The I-131 radioisotope is used in nuclear medicine for diagnosis and therapy. The I-131 radioisotope is produced by wet distillation at Bandung Nuclear Research Center and generated about 4,875 Itr of liquid waste containing 2,532.8 ppm of tellurium and 1,451.8 ppm chromium at pH 1. Considering its negative impact to the environment caused by toxic behaviour of tellurium and chromium, it is necessary to treat chemically that's liquid waste. The research of chemical treatment of tellurium and chromium liquid waste from I-131 radioisotope production has been done. The steps of process are involved of neutralisation with NaOH, coagulation-flocculation process for step I using Ca(OH) 2 coagulant for precipitation of sulphate, sulphite, oxalic, chrome Cr 3+ , and coagulation-flocculation process for step II using BaCI 2 coagulant for precipitation of chrome Cr 6+ and tellurium from the supernatant of coagulation in step I. The best result of experiment was achieved at 0.0161 ppm of chromium concentration on the supernatant from coagulation-flocculation of step I using 3.5 g Ca(OH) 2 for 100 ml of liquid waste, and 0.95 ppm of tellurium concentration on the final supernatant from coagulation-flocculation by of step II using 0.7 g BaCI 2 for supernatant from coagulation of step I. (author)

  17. Study of the therapeutic dose and the clinical effect on Graves' disease with I-131 treatment

    Dang, Y.

    2005-01-01

    Full text: Graves' disease is being treated with I-131 for more than 40 years in China. Previously the dose of I-131 used to be calculated using the 'Quimby' formula. We have now observed that the dose of I-131 administered to patients is now lower in recent years than the early years. The radioactive iodine uptake by the thyroid gland has also changed significantly over a period of time. In this paper we intend to explore these reasons and to research the relationship between the dose and the effect as well as the main cause of the incidence of the hypothyroidism. The parameters in 'Quimby' formula including I-131 uptake, effective half-life and thyroid weight were analyzed and compared with each year data from 1961 to 1988 and subjected to multiple regression analysis to determine the influence on the calculation of dose in 4465 patients. The therapeutic effects were compared with the data of the clinical follow-up of patients between 1961-1973 and 1978-1988 in 748 patients. The factors which might lead to the hypothyroidism were investigated with the non-condition logistic regression. The I-131 uptake was repeatedly measured within one week in 100 patients to identify the changing pattern of the I-131 uptake and its influence on the administered therapeutic dose. We observed an increase in the value of I-131 uptake. The value of I-131 uptake showed an increase after 1977, as well as a prolongation of effective half-life after 1973. The main reason for these changes being a replacement of the equipment in 1977 (G-M counter tube was replaced by scintillation counter), and the other reason being salt iodization in China in 1973. These two factors resulted in a significant reduction in the administered dose of I-131 during the period 1974-1988 as compared to the previous period 1961-1973; the mean administered doses being 168.35MBq and 330.33MBq respectively. The result of multiple regression analyses suggested that the thyroid weight and the effective half

  18. Recurrence of pheochromocytoma in 11 years old school child, diagnosed by I-131 MIBG

    Jara Yorg, J. A; Arias, Cohl; Gimenez, J; Rodriguez, E; Ortiz, L; Mendieta, B; Ayala, R. M; Rodriguez, C; Delgadillo, J. L

    2000-01-01

    Pheocromocytoma is a paraganglioma with an incidence of arterial hypertension approximately of 1%,but its diagnosis has several important issues from the clinical point of view. 1-The tumor resection frequently cure the hypertension. 2.-Its manifestations might simulates other diseases like carcinoid Sx, hypertiroidism,etc. 3.-It is a familiar disease transmitted by an autosomic dominant way. It is 10% bilateral,10%extraadrenal,10% occur in children and 10% are malignant. We present a case of pheochromocytoma recurrency in a young girl,11 y.o. operated 8 months before, at the Clinical Hospital, National University of Paraguay, School of Medicine for a right suprarenal gland pheochromocytoma of 2cms of diameter, who consults the Pediatric Department for arterial hypertension and cefalea. She also had a Von Hippel Sx and Glaucoma. Nuclear Medicine is a non invasive method that use the I-131 Methayodobencylguanidine(MIBG-I-131) with high accuracy to diagnose and treat both neuroblastoma and pheochromocytoma I-131 MIBG is the gold standard for the diagnosis of both entities with a sensitivity between 94-100%6-7 and specificity of 100% being the best method to evaluate these diseases in the pre and post operatory (Au)

  19. The influence of I-131 therapy on FDG uptake in differentiated thyroid cancer

    Hung Guanguei; Lee Kwowhei; Liao Peiyung; Yang Liheng; Yang Kwangtao

    2008-01-01

    18F-fluorodeoxyglucose positron emission tomography (FDG-PET) [or PET/computed tomography (CT)] is more likely to show false-negative results when it is performed shortly after chemotherapy and/or radiotherapy because of ''metabolic stunning''. The present study aimed to evaluate the influence of I-131 therapy on FDG uptake and the detection of recurrence or metastasis of differentiated thyroid cancer (DTC). We retrospectively enrolled 16 consecutive FDG-PET/CT studies which had been performed in patients with DTC with elevated thyroglobulin (TG) but negative I-131 whole-body scan. All studies were performed under L-thyroxine suppression. The patients were divided into groups A and B for PET/CT performed within 4 months of I-131 therapy or no such therapy, respectively. Each lesion identified on PET/CT was characterized using a 5-point scale by visual analysis: 0=definitely benign, 1=probably benign, 2=equivocal, 3=probably malignant, and 4=definitely malignant. The maximum standardized uptake value (SUV max ) in each lesion was also measured for semiquantitative analysis. We compared the visual grading and SUV max of the lesion of highest FDG uptake between groups A and B. For visual analysis, group B had significantly more patients with an uptake score of 3 or 4 than group A (80% vs. 17%, P=0.01). In addition, there were significantly more equivocal results from group A than from group B (67% vs. 10%, P=0.02). If the patients with the highest uptake scores of 2, 3, and 4 were considered to be positive for local recurrence or metastasis, there would be no significant difference between the positive rates of groups A and B (83% vs. 90%, P=0.7). However, the mean SUV max of positive results was significantly lower for group A than for group B (3.1±0.9 and 6.6±3.5 respectively, P=0.02). The preliminary results suggested that FDG uptake in DTC may be negatively influenced by I-131 therapy within 4 months, resulting in lower FDG uptake and more equivocal results

  20. Radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages

    Chaudakshetrin, P.; Pusuwan, P.; Sritongkul, N.; Tuntawiroon, M.

    2007-01-01

    Full text: Therapeutic doses of I-131 for treatment of thyroid cancer are administered orally in liquid or capsule form. During the last few years, a total number of patients loaded in our isolation ward increased from 4 to 10 patients per week. When considering radiation safety precautions for attending technologists, it is preferable to use the dose in capsules. The purpose of this study is to compare radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages in capsules and in liquid form in a closed system. Materials and Methods: Three year radiation exposure to technologists during I-131 administration was analyzed. From January 2004 to June 2005 dose administration was in liquid form (n=263) and from July 2005 to February 2007 in capsules (n=541). Radiation dose assessment was performed with an electronic personal dosimeter (PDM 112). The dose rate in μSv and time spent per patient were recorded. Results: Dose received per patient when I-131 was given in a liquid was 3.50 ± 1.67 μSv and 1.17 ± 0.66 μSv when given in capsules. Compared with the use of a liquid, capsules significantly reduced radiation dose to technologists by 66% (P < 0.001). These doses received depended not only on the administered activity but also on the time, distance and shielding. Time spent per patient, including a brief visit before the time of dosing to explain the procedure and answer questions was reduced slightly from 4.4 ± 2.2 to 3.7 ± 1.8 minutes (P < 0.01). These correspond to a reduction in a yearly dose to 1 technologist by 40%, from 0.63 mSv to 0.38 mSv from dosing to 175 and 325 patients respectively. Conclusions: The measured doses clearly showed that handling of I-131 therapy dosages either in a liquid form or capsules are not the major contributors to the technologist's radiation exposure in routine clinical practice. However, one has to be cautious and follow good work practice to avoid risk of radiation exposure and radioiodine

  1. Thyroid uptake of I-131 during anti-thyroid drug treatment

    Hoque, M.; Alam, F.; Haque, F.S.; Karim, M.A.; Fariduddin, M.

    2004-01-01

    Hyperthyroidism is a global ailment and its treatment is very promising either by ant-thyroid drug or by radioiodine. Iodine-131 uptake test is very important for evaluation of hyperthyroid in respect to its therapy and to exclude thyroiditis. This study was performed to observe the thyroid uptake pattern during intake of anti-thyroid medicine and workout the possibility to start I-131 therapy just after withdraw of antithyroid drug without waiting few days. In this study total 252 patient's I-131 uptake test is performed. Among the patient 135 (53.57%) were female, 117 (64.43%) were male. All this patients were hyperthyroid both clinically and biochemically. Thyroid uptake was taken to all patients at 24 hours after oral administration of 5 to 10 micro-curie of I -131. Uptake was taken by an uptake system and recorded as percentage uptake. These patients are grouped into three categories. Group-A-newly diagnosed cases, who have not taken antithyroid drug or I-131 therapy, there were 82 patients in this group, and their mean uptake was 37.12 ±18.5%. Group B - this group of patients were studied during intake of antithyroid medicine, there were 130 patients in this group and their mean uptake was 34.34±16.0%. Group-B patients were further divided in two sub-groups, patients having antithyroid drug for 1 to 3 weeks (group-B 1), group B1 have mean uptake 37±21% and those were taking antithyroid for 3 weeks to 2 years (group-B2), group B2 have uptake 34.34±20%. Group C- these patients are taken from those patients who had withdrawn antithyroid drug for 3 days to 3 months, there were 40 such patients. Group C further divided into two sub-group, group-C1 (stopped for 3-10 days) and group C2 (stopped for 11 days to 3 months). Group C1 had mean uptake 38±16% and group C2 had mean uptake 35±19%. From this study it is observed that Iodine-131 uptake percentage of untreated hyperthyroid; during antithyroid drug treatment and after withdraw of antithyroid drug almost

  2. Radioimmunotherapy of Nude Mice Bearing Human Colon Carcinoma with I-131 Labeled Anti-carcinoembryonic Antigen

    Kim, Byung Tae; Lee, Kyung Han; Kim, Sang Eun; Choi, Yong; Chi, Dae Yoon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Chung, Hong Keun

    1995-01-01

    This study was designed to evaluate the effects of various factors on the therapeutic effect of the I-l3l labeled anti-carcinoembryonic antigen monoclonal antibody(anti-CEA antibody). Tetrazolium-based colorimetric assay (MTT) was used to compare in vitro cytotoxicity of 3 Korean colon cancer cell lines (SNU-C2A, SNU-C4, SNU-C5) for selection of proper 2 cell lines in this study. The changes of the size of tumor which was xenografted to nude mice (balb/c nu/nu) were compared in 4 groups (group treated I-131 labeled anti-CEA antibody, group treated with non-radiolabeled anti-CEA antibody, group treated with I-131. labeled anti-human chorionic gonadotropin monoclonal antibody (anti-hCG antibody) as nonspecific antibody, and group injected with normal saline as a control). Immunohistochemical staining and in vivo autoradiography were performed after excision of the xenografted tumor. The results were as below mentioned. The in vitro cytotoxic effect of I-131 labeled anti-CEA antibody is most prominent in SNU-C5 cell line between 3 cancer cell lines. The changes of xenografted tumor size in both SNU-C4 and SNU-C5 cell tumors at the thirteenth day after injection of the antibodies were smallest in the group treated with I-131 labeled anti-CEA antibody (SNU-C4/SNU-C5; 324/342%) comparing with other groups, group treated with anti-CEA antibody (622/660%), group treated with I-131 anti-hCG antibody (538/546%), and control group(1030/724%) (p<0.02 in SNU-C4 and p<0.1in SNU-C5 at the 13th day after injection of antibodies). On the thirteenth day after injection of the antibodies nude mice were sacreficed to count the radiouptake of tumor and to check the changes of tumor size. Correlations between radiouptake and change of tumor size were calculated in each groups and significant negative correlation was only obtained in the group treated with I-131 anti-CEA antibody (p<0.05). There were no correlations between antigenic expression of carcinoembryonic antigen and

  3. The physico-chemical I-131 species in the exhaust air of a boiling water reactor (BWR 5)

    Deuber, H.

    1984-02-01

    In a German boiling water reactor, the pysico-chemical I-131 species were determined in the plant exhaust and in the individual exhausts during four months. These measurements aimed in particular at determining the percentage and the source of the radiologically decisive elemental I-131 released to the environment. On an average 13% of the I-131 discharged with the plant exhaust consisted of elemental iodine. This was largely released with the exhausts from the reactor building and from the turbine building. The main component was organic-bound I. (orig./HP) [de

  4. Control system of liquid effluents generated in treatment with I-131

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R.

    2015-09-01

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  5. Dosimetry study of [I-131] and [I-125]- meta-iodobenz guanidine in a simulating model for neuroblastoma metastasis.

    Roa, W H; Yaremko, B; McEwan, A; Amanie, J; Yee, D; Cho, J; McQuarrie, S; Riauka, T; Sloboda, R; Wiebe, L; Loebenberg, R; Janicki, C

    2013-02-01

    The physical properties of I-131 may be suboptimal for the delivery of therapeutic radiation to bone marrow metastases, which are common in the natural history of neuroblastoma. In vitro and preliminary clinical studies have implied improved efficacy of I-125 relative to I-131 in certain clinical situations, although areas of uncertainty remain regarding intratumoral dosimetry. This prompted our study using human neuroblastoma multicellular spheroids as a model of metastasis. 3D dose calculations were made using voxel-based Medical Internal Radiation Dosimetry (MIRD) and dose-point-kernel (DPK) techniques. Dose distributions for I-131 and I-125 labeled mIBG were calculated for spheroids (metastases) of various sizes from 0.01 cm to 3 cm diameter, and the relative dose delivered to the tumors was compared for the same limiting dose to the bone marrow. Based on the same data, arguments were advanced based upon the principles of tumor control probability (TCP) to emphasize the potential theoretical utility of I-125 over I-131 in specific clinical situations. I-125-mIBG can deliver a higher and more uniform dose to tumors compared to I-131 mIBG without increasing the dose to the bone marrow. Depending on the tumor size and biological half-life, the relative dose to tumors of less than 1 mm diameter can increase several-fold. TCP calculations indicate that tumor control increases with increasing administered activity, and that I-125 is more effective than I-131 for tumor diameters of 0.01 cm or less. This study suggests that I-125-mIBG is dosimetrically superior to I-131-mIBG therapy for small bone marrow metastases from neuroblastoma. It is logical to consider adding I-125-mIBG to I-131-mIBG in multi-modality therapy as these two isotopes could be complementary in terms of their cumulative dosimetry.

  6. A preliminary study of radioimmunoimaging of ovarian malignancy with I-131 labelled CEA monoclonal antibody

    Hu Likuan

    1988-01-01

    Ten cases of ovarian cancers have been detected with I-131 labelled CEA McAb and computer assisted clual radionuclide subtraction technique. The lesions (both primary and secondary) are clearly visualized and proved by surgical and pathohistological findings. 30 of 31 metastatic lesions are localized with a positive rate 97%. It seems to be a sensitive and specific procedure for early diagnosis of ovarian cancer so far. It is also valuable for staging clinical course and making decision on treatment, assessing the prognosis of ovarian cancer as well

  7. Myocardial distribution of I131-labeled hexadecenoic acid in relation to the dog local coronary flow

    Riche, F.; Busquet, G.; Pilichowski, P.; Wolf, J.E.; Mathieu, J.P.; Comet, M.; Pernin, C.; Vidal, M.; Vincens, M.; Godart, J.

    1981-01-01

    20 anesthetized and thoracotomized dogs are studied. The local myocardial blood flow is measured with sup(99m)Tc human albumin microspheres. The intramyocardial distribution of the 16-I(131)-9-hexadecenoic acid in relation to local blood flow is studied in basal conditions (7 dogs), after experimental infarction (6 dogs) and postischemic reactive hyperhemia (7 dogs). We conclude that during basal condition, after infarction but not during reactive hyperhemia, the distribution of the labeled fatty acid reflect the local variations of blood flow [fr

  8. Septal penetration correction in I-131 imaging following thyroid cancer treatment

    Barrack, Fiona; Scuffham, James; McQuaid, Sarah

    2018-04-01

    Whole body gamma camera images acquired after I-131 treatment for thyroid cancer can suffer from collimator septal penetration artefacts because of the high energy of the gamma photons. This results in the appearance of ‘spoke’ artefacts, emanating from regions of high activity concentration, caused by the non-isotropic attenuation of the collimator. Deconvolution has the potential to reduce such artefacts, by taking into account the non-Gaussian point-spread-function (PSF) of the system. A Richardson–Lucy deconvolution algorithm, with and without prior scatter-correction was tested as a method of reducing septal penetration in planar gamma camera images. Phantom images (hot spheres within a warm background) were acquired and deconvolution using a measured PSF was applied. The results were evaluated through region-of-interest and line profile analysis to determine the success of artefact reduction and the optimal number of deconvolution iterations and damping parameter (λ). Without scatter-correction, the optimal results were obtained with 15 iterations and λ  =  0.01, with the counts in the spokes reduced to 20% of the original value, indicating a substantial decrease in their prominence. When a triple-energy-window scatter-correction was applied prior to deconvolution, the optimal results were obtained with six iterations and λ  =  0.02, which reduced the spoke counts to 3% of the original value. The prior application of scatter-correction therefore produced the best results, with a marked change in the appearance of the images. The optimal settings were then applied to six patient datasets, to demonstrate its utility in the clinical setting. In all datasets, spoke artefacts were substantially reduced after the application of scatter-correction and deconvolution, with the mean spoke count being reduced to 10% of the original value. This indicates that deconvolution is a promising technique for septal penetration artefact reduction that

  9. Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting

    Orval R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  10. I-131 dose response for incident thyroid cancers in Ukraine related to the Chornobyl accident.

    Brenner, Alina V; Tronko, Mykola D; Hatch, Maureen; Bogdanova, Tetyana I; Oliynik, Valery A; Lubin, Jay H; Zablotska, Lydia B; Tereschenko, Valery P; McConnell, Robert J; Zamotaeva, Galina A; O'Kane, Patrick; Bouville, Andre C; Chaykovskaya, Ludmila V; Greenebaum, Ellen; Paster, Ihor P; Shpak, Victor M; Ron, Elaine

    2011-07-01

    Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case-control studies, and studies of prevalent cancers. To address this limitation, we evaluated the dose-response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. The cohort consists of individuals radioactivity measurements taken within 2 months after the accident, environmental transport models, and interview data. Excess radiation risks were estimated using Poisson regression models. Sixty-five incident thyroid cancers were diagnosed during the second through fourth screenings and 73,004 person-years (PY) of observation. The dose-response relationship was consistent with linearity on relative and absolute scales, although the excess relative risk (ERR) model described data better than did the excess absolute risk (EAR) model. The ERR per gray was 1.91 [95% confidence interval (CI), 0.43-6.34], and the EAR per 10⁴ PY/Gy was 2.21 (95% CI, 0.04-5.78). The ERR per gray varied significantly by oblast of residence but not by time since exposure, use of iodine prophylaxis, iodine status, sex, age, or tumor size. I-131-related thyroid cancer risks persisted for two decades after exposure, with no evidence of decrease during the observation period. The radiation risks, although smaller, are compatible with those of retrospective and ecological post-Chornobyl studies.

  11. Evaluation for Preparation of I-131-MIBG for Diagnosis and Therapy Neuroblastoma

    Laksmi Andri A; Purwoko; Sri Setyowati; Maskur; Cahya Nova Ardianto; Adang Hardi G

    2012-01-01

    Evaluation for preparation of 131 I-MIBG have been carried out. Production/preparation of 131 I-MIBG was carried out by labeling MIBG with I-131, the radiochemical purity of 131 I-MIBG was analysed using TLC/paper chromatography. The stability in the human body by using fresh human plasma, at room temperature and at 8°C was carried out. The chemical purity of synthesized MIBG was found to be > 95%, the labeled MIBG with I-131 was analysed using TLC/paper chromatography. The radiochemical purity of 131 I-MIBG was obtained at higher than 95 %. The stability of labeled MIBG in fresh human plasma and at 8°C was stable up to 141 hours, while at room temperature was stable up to 120 hours. The results of labeling of 131 I-MIBG from 2010-2012 showed that these products were colorless clear solution with pH between 5.5.0-7.0, sterile and pyrogen-free, radiochemical purity > 95%. The quality control results were found to be met with the requirements of 131 I-MIBG injection solution used for diagnosis and therapy of neuroblastoma in Hospital. (author)

  12. Post-Irradiation Behaviour of I131 in TeO2

    Jaćimović, Lj.; Stevović, J.; Veljković, S.R.

    1965-01-01

    The system I 131 in TeO 2 is interesting because little is known about thermal chemical changes in this target. Radioiodine was produced by neutron irradiation of TeO 2 in the reactor. Irradiated TeO 2 was dissolved in diluted NaOH. The analysis of the iodine valency forms was made by ion exchange techniques. The thermal and radiation stability of TeO 2 was studied by using the spectrophotometric method for the determination of tellurium. Post-irradiation annealing of I 131 in TeO 2 was studied in dependence on the time and temperature of the heating. The main tendency of annealing was the reduction of radioiodine. The time dependence of this process indicates a fast change at high temperatures. The curves are more complex at lower temperatures. The annealing may appear complex because of the variety of thermal reactions of iodine intermediary. It may react with products of the following processes: tellurium recoil and corresponding hot zone, beta transition of Te 131 and TeO 2 itself. The kinetics of these changes was considered and an estimation of the processes during annealing was made. The influence of the neutron flux on the kinetics of annealing was also studied. (author) [fr

  13. Effects of changed working methods on personnel doses at a I-131 and afterloading therapy ward

    Lange, D.; Wolf, G.; Georgi, P.; Bauer, M.

    1985-01-01

    The external load of the personnel from I-131 therapy can be kept small (almost 'neglectable') by appropriate behaviour without keeping patients 'under-lock and key'. The marked decrease in personnel doses is due to improved radiation protection for afterloading therapy (gynecological Ra-therapy, Cs-137-therapy) by technical equipment. This therapy is now possible but with the door of the application room closed; when the door is opened, the instruments automatically go back to their original position. From 1975 through 1982, there were remote control errors forcing the personnel to withdraw the instruments to the safe manually. Despite working regulations the personnel was able to go into the room without prior instrument withdrawal. The personnel doses so received were within the tolerance limits, however markedly above the inevitable values. Because of regular thyroid gland examination of the personnel there is proof for the fact that the radiation load of this organ from I-131 is probably smaller than 2% (6 mSv/a=600 mrem/a) of the annual limit value of 0.3 Sv (30 rem) which corresponds to 6 times the value of normal load. (orig./HP) [de

  14. Methodology for Gamma cameras calibration for I-131 uptake quantification in Hyperthyroidism diseases

    Lopez Diaz, A.; Palau San Pedro, A.; Martin Escuela, J. M.; Reynosa Montejo, R.; Castillo, J.; Torres Aroche, L.

    2015-01-01

    Optimization and verification of Patient-Specific Treatment Planning with unsealed I-131 sources is a desirable goal from medical and radiation protection point of view. To obtain a practical protocol to combine the estimation of the related parameters with patient's specific treatment dose in hyperthyroidism disease, 3 equipment were studied (Iodine Probe, a Philips Forte Camera with pin-hole collimators and a Mediso Nucline with HEGP for planar and SPECT techniques) and crossed calibrated. The linear behaviour on diagnostic and therapeutic activity range was verified, showing a linear correlation fitting factor R 2 > 0.99. The differences between thyroid uptake determinations in all equipment were less than 6% for therapeutic activities and less than 1.1% in the diagnostic range. The combined protocol to calculate, with only one administration of I 131 , all the necessary parameters to the treatment dose estimation in 2D or 3D, avoiding wasting time with gamma cameras, was established and verified. Following this protocol the difference between apparent and calculated activities were less than 3%. (Author)

  15. Measuring the actual I-131 thyroid uptake curve with a collar detector system: a feasibility study

    Brinks, Peter; Van Gils, Koen; Dickerscheid, Dennis B.M.; Habraken, Jan B.A. [Department of Medical Physics, St. Antonius Hospital, Nieuwegein (Netherlands); Kranenborg, Ellen; Lavalaye, Jules [Department of Nuclear Medicine, St. Antonius Hospital, Nieuwegein (Netherlands)

    2017-06-15

    Radionuclide therapy using I-131 is commonly used for the treatment of benign thyroid diseases. The therapeutic dose to be administered is calculated based on the type of disease, the volume of the thyroid, and the measured uptake percentage. This methodology assumes a similar biological half-life of iodine, whereas in reality a large variation in biological half-life is observed. More knowledge about the actual biological half-life of iodine for individual patients will improve the quantification of the delivered radiation dose during radioiodine therapy and could aid the evaluation of the success of the therapy. In this feasibility study we used a novel measurement device [Collar Therapy Indicator (CoTI)] to measure the uptake curve of patients undergoing I-131 radioiodine therapy. The CoTI device is a light-weight wearable device that contains two independent gamma radiation detectors that are placed in a collar. By comparing results of thyroid uptake measurements with results obtained with a gamma camera, the precision of the system is demonstrated. Additionally, for three patients the uptake curve is measured during 48 h of admission in the hospital. The presented results demonstrate the feasibility of the new measurement device to measure the uptake curve during radioiodine therapy. (orig.)

  16. SU-F-T-222: Dose of Fetus and Infant Following Accidental Intakes of I-131 by the Mother

    Wang, Y [The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan (China); Hu, P [Fudan University Shanghai Cancer Center, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: To estimate the calculation of absorbed dose to the fetus and infants from intakes of I-131 by the mother. Thus provide some advice to the radioprotection of radioactive accident. Methods: In this clinical case, a staff of nuclear medicine accidently intake I-131 during (10–12 weeks) and after pregnancy. The infant was born at full term, but both lobes of the thyroid gland were found to be absent (bilobar thyroid agenesis). It was suspected that the fetal thyroid agenesis may be related with mother’s contamination of I-131 during pregnancy. Urine samples for 24h were collected at different times after administered and radioactivity were measured to calculate the dose of intake I-131. Calculate the intake I-131 by the results of personal TLD dosimeter. We adopted the mean of two calculated results as the I-131 intake. According to the dose of intake I-131 by the mother, effective dose and absorbed dose of thyroid for mother, fetus and infant were calculated. Results: The intake of I-131 was estimated for 8.18 mCi. I-131 intake was calculated for 7.9 mCi based on data of TLD dosimeter. We adopted the mean of two results as the I-131 intake. The final result was 8.0 mCi. Effective dose and absorbed dose of thyroid for mother were 7.3Sv and 164 Gy, effective dose and absorbed dose of thyroid for fetus were 2.035 Sv and 40.7 Gy, effective dose and absorbed dose of thyroid for infant were 16.25 Sv and 355Gy. Conclusion: The intake during pregnancy was about 1mCi. The absorbed dose of thyroid of the mother was 19.5Gy, whereas the effective of infant was estimated for 40.7Gy. The function of the mother’s thyroid was normal after diagnosis. But the infant was diagnosed as bilobar thyroid agenesis.

  17. Status of urinary iodine and I-131 uptake after universal iodination of common salt

    Alam, F.; Begum, F.; Haque, M.; Karim, M.A.; Faruque, O.; Ali, L.; Khan, A.K.A.

    2002-01-01

    This work was carried out in the Institute of Institute of Nuclear Medicine (INM), Bangabandhu Sheikh Mujib Medical University and Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorders, Dhaka. Here we have tried to explore present status of urinary iodine and uptake status in Bangabandhu. Period study was from 1998 to 2000. Total study population was 300, of them 84 was male and 216 was female. Populations of all social and economic strata have been studied, starting from bottoms to top-level income groups as well as urban, rural and suburban populations are included randomly. We studied I-131 uptake and urinary iodine. I-131 given orally in liquid form and the quantity accumulated by the thyroid gland at 24 hours intervals of time is measured using a gamma scintillation counter. Gamma-ray emission of 364 keV energy by I-131 is detected gamma scintillation counter. Urinary iodine is estimated by CIS-BIO kit. Urine is digested with chloric acid under mild conditions and determined manually by its catalytic role in the reduction of ceric ammonium sulfate in the presence of arsenious acid. The uptake was grouped into four categories according to their uptake percentage. Group-A; (lowest uptake group) 99 subject, have uptake between 0 to 4.9%, Group-B; 100 subjects, (relatively low uptake) who have uptake between 4.91-9.9%, group-C; 73 subjects, who have uptake between 10-30% and in-group D, there was 28 subjects their uptake was above 30%. We have also found in group-A median uptake is 3.0% and urinary iodine level is 43.31 μg/dl, in group-B median uptake is 7.0% and urinary iodine level is 33.95 μg/dl, in group-C median uptake is 23.0% and urinary iodine level is 12.97 μg/dl, in group-D median uptake is 34.0% and urinary iodine level is 9.35 μg/dl. We have found 1.04% have severe type low urinary iodine, 3.48% moderate type of low urinary iodine, 3.48%, 16.72% mild type of low urinary iodine and 78.74% have normal

  18. Comparison of four different protocols of I-131 therapy for toxic single thyroid nodule

    Zakavi, S.R.; Mousavi, Z.

    2007-01-01

    Full text: Aim: Radio-iodine therapy is the preferred method of treatment of toxic thyroid nodule, however there is no consensus on the dose of I-131 administered. The aim of this study was to compare 4 different dose protocols for treatment of these patients. Methods and patients: All patients with hyperthyroidism and single hot thyroid nodule were referred for I-131 therapy after thyroid physical examination, ultrasonography and measurements of 24 hours thyroid iodine uptake. They were randomly entered in one of 4 groups: fixed low dose (FLD), fixed high dose (FHD), calculated low dose (CLD) and calculated high dose (CHD). In fixed dose protocol, 13mCi of I-131 was administered for patients in FLD group and 22.5mCi was administered for patients in FHD group. Quimby formula was used for calculation of radio-iodine dose in calculated groups with 90-100uCi and 180-200uCi per gram of thyroid weight in CLD and CHD groups respectively. Patients were followed up for a mean of 2, 5, 10 , 22 and 50 months later and physical exam and measurements of thyroid values were done in each follow up. Results: One hundred and sixteen patients were studied. One 72 year old patient was decreased 2 months after treatment due to coronary artery disease and 18 other patients did not complete follow up. From 97 patients who completed follow- up 8 patients were male and 89 patients were female. Mean age of patients were 43.3 years (SD=13.4) and mean thyroid nodule weight was 51 grams (SD=19.2).Mean 24 hours thyroid uptake was 48.07% (SD=14.07). Follow up was done up to 85 months with a median follow up of 14 months. Twenty two patients were in CHD group, 23 patients in CLD, 25 patients in FLD and 27 patients in FHD group. No significant difference was noted in 4 groups regarding age, sex, thyroid uptake and thyroid weight. The mean administered dose was 10.5mCi (SD=3.2) and 18.7mCi (SD=5.3) in CLD and CHD groups respectively (P<0.001). In CHD group, hyperthyroidism was decreased from 33

  19. Internal Dosimetry Of I-131 For Radiation Workers Based On Analysis Of The Human Urine And Liquid Scintillation Counting

    Nguyen Van Hung; Pham Hung Thai; Le Van Ngoc

    2011-01-01

    Internal dosimetry of I-131 for radiation workers based on analysis of the human urine, measuring radioactivity by the liquid scintillation system, and dose calculation by the specialized code has been firstly studied at the Nuclear Research Institute. Urine samples from the subjects internally contaminated with I-131 through respiratory ways were collected, chemically processed, measured beta radioactivities of I-131 by the liquid scintillation system of ALOKA-LSC-6100, and then thyroid doses and effective ones for whole-body were calculated by using the specialized code of LUDEP 2.0. Based on chemically separation procedure for I-131 in urine samples and the low background HPGe gamma spectrometer of Canberra for measuring radioactivity, efficiency for chemical separation was determined to be (86.1 ± 5.0)%. The experimental results for 9 subjects with urine samples to be collected during 4 operating courses of Dalat nuclear reactor with production of I-131 (from June to September, 2010) were shown that thyroid doses and effective ones for whole-body for each course of I-131 production were in ranges of from 0.11 to 13.00 mSv and from 0.01 to 0.71 mSv, respectively. Therefore, totally average doses per year for thyroid and whole-body were less than the correlative levels of permissible doses. Besides, the liquid scintillation method was also compared experimentally with the gamma spectrometry (measuring directly urine samples by the gamma spectrometer to be carried out at the Institute before) was shown that errors on dosimetric results between them were less than 12%. This was proved the dosimetry has had a confidence, and it could be applied for internal dosimetry for radiation workers contacting with unsealed sources of I-131 in radiation installations as well as for diagnostic and therapeutic patients in health ones. (author)

  20. The anti-thyroid antibody and I-131 uptake in thyroid disorder patient

    Faridul Alam; Fatema Sultana Haque; Mohammad Abdul Karim; Liaquat Ali; Omer Faruque; Azad Khan, A.K.

    2004-01-01

    The problem of thyroid disorder is extensive in Bangladesh, even more than that of other developing countries. The high incidence rate of goiter is reduced after universal iodine supplement. This study has been undertaken to study the an-thyroid anti-body level among the thyroid disorder population (anti-TPO and anti-thyrogobulin antibody) and TSAb among Graves' disease and sub-acute thyroiditis. This study was performed over 300 persons of them 150 have some type of thyroid (patient) disorder and 150 have got no clinical thyroid disorder (volunteer). We also studied TSH receptor anti-body (TSAb) in 112 Graves' disease patients and 86 patients with sub-acute thyroiditis. All the patient had I-131 Uptake in 24 hours. Among the patient 42(28%) had elevated anti-TPO, 12(8%) had borderline and 96(64%) had normal anti-TPO. It was found the uptake percentage of this group of patient hade slight lower than average uptake of our population. 13±5% It was found that 28(18.6%) had elevated anti thyrogobulin anti-body, 9 (6.2%) had borderline and 113(75.3%) had normal level anti thyrogobulin anti-body. It was also that found the uptake percentage of this group of patient had slight lower than average uptake of our population. We also found that 21% patient had elevated both the antibodies. Among the normal volunteer 24(16%) had elevated anti-TPO, 8 (5.3%) had borderline and 118(78.7%) had normal level of anti-TPO. Thyroid 1-131 uptake was 15±4%. It was found that 14(9.3%) had elevated anti thyrogobulin anti-body, 6(4.1%) had borderline and 130 (76.6%) had normal level of anti thyrogobulin anti-body. Among the normal volunteer 6% had elevated both the antibodies. It was found 91% patient Graves' disease had positive TSAb and 92% of' sub-acute thyroiditis has negative TSAb, I-131 uptake was 31±8% among this group of patient.. Thyroid stimulating antibody is found in 91% of Graves' disease and very few patient with sub-acute thyroiditis. The uptake of I-131 in sub

  1. Model of iodine metabolism in a T3-thyrotoxic patient undergoing I-131 therapy

    Ahuja, S.; Price, R.; Brill, A.B.; Dobyns, B.M.; Berman, M.

    Data on radioactivity in the thyroid, urine, serum, butanol-extractable iodine (BEI) and chromatographic fractionations of BEI, obtained during four I-131 therapeutic treatments of a T 3 -thyrotoxic patient, have been analyzed and simulated with the help of a 7-compartment model. Good fits to most of the data can be obtained with both the dose-independent and dose-dependent models. A model with 3 or 4 compartments, which provides adequate fits to iodine kinetic data in most euthyroid and hyperthyroid patients is not satisfactory in the case of this patient. Thus, to represent iodine metabolism during T 3 -thyrotoxicosis therapy, we find that it is necessary to provide for separate biochemical pathways for the BEI components as well as the butanol-insoluble compounds released by the thyroid gland

  2. Radioimmunoscintigraphy with I-131-labelled anti-CEA monclonal antibody in colorectal cancer patients

    Xie Tianhao

    1988-01-01

    Twenty three colorectal carcinoma and two benign polyposis patients with operatively and histologically proven were studied by radioimmunoscintigraphy, using anti-CEA monoclonal antibodies (C14-17 and C50) radiolabeled with I-131 . Computer assisted processing for the subtraction of Tc-99m background radioactivity was used to enhance the detection and localization of tumor which is visualized by immune scintigraphy. The size of tumor and the ratios of tumor to nontumor (T/NT) are two very important factors for the external immunoscintigraphy. The antibody uptake and retention in tumor are likely to depend on the degree of vascularity and diffusion into the viable tumor mass. Based upon the obtained results, the sensitivity of the method (true-poditive) was 91%, its specificity (true-negative) was 100%. This study thus indicates that radioimmunoscintigraphy of cancer with radioactive anti-CEA monoclonal antibody is very uaeful in the diagnoses of patients with CEA-containing neoplasms

  3. Simultaneous treatment of toxic diffuse goiter with I-131 and antithyroid drugs: a prospective study

    Steinbach, J.J.; Donoghue, G.D.; Goldman, J.K.

    1979-01-01

    We report a prospective study to evaluate the effect of antithyroid drugs containing the sulfhydryl radical on the outcome of I-131 (RAI) therapy. Twenty-four male patients with toxic diffuse goiter were assigned randomly into two treatment groups: Group A received RAI treatment while on antithyroid drugs after attainment of euthyroidism; Group B received no antithyroid drugs before, or when, RAI was given. Patients in each group received a dose of RAI calculated to deliver approximately 5000 rads per treatment. The incidence of hypothyroidism at 12 mo was 8% for Group A and 36% for Group B (p 0.45). The improved therapeutic outcome of patients in Group A suggests that further validation of the method in a larger patient population, including females, is warranted

  4. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop

    Tedjasari, R S; Lubis, E [Radioactive-Waste Management Technology Centre, National Atomic Energy Agency of Indonesia(Indonesia)

    1996-07-01

    Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.

  5. Use of I-131 labeled, murine Fab against a high molecular weight antigen of human melanoma: Preliminary experience

    Larson, S.M.; Carrasquillo, J.A.; McGuffin, R.W.

    1985-01-01

    High molecular-weight antigen (HMWA) is tumor-associated proteoglycan of human malignant melanoma. I-131 labeled Fab fragments of these specific antibodies were used for preliminary feasibility studies for radioimmunodetection and therapy of human subjects who had inoperable metastatic melanoma. Ten patients received tracer doses of I-131 (anti-HMWA) Fab. All patients (8/8) who had melanoma lesions greater than 1 cm by correlative diagnosis methods had one or more lesions that had localization to tumor of the radiolabelled Fab. In all, 17 of 23 (74%) documented metastases were seen. Two patients who had avid uptake received potentially radiotherapeutic doses. For both of these patients, whole imaging studies showed that the localization of the high dose I-131 Fab was predominantly in tumor. On whole body images, the anti-Fab HMWA appears to be more tumor selective than Fab preparations that target the p97 antigen for melanoma, and there is less uptake in liver

  6. A significant discrepancy of uptake between I-131 MIBG and F-18 FDG in a patient with malignant paraganglioma

    Kim, Jong Su; Kim, Hyun Keun; Choi, Kyu Young; Park, Hyung Ki; Kim, Eun Sil; Kim, Yun Kwon; Kim, So Yon [National Police Hospital, Seoul (Korea, Republic of)

    2007-06-15

    A 38-year-old man who was diagnosed with malignant paraganglioma underwent computed tomography (CT) and I-131 metaiodobenzylguanidine (MIBG) scan. CT showed extensive lymph node enlargement in right iliac area and retroperitoneum with severe hydronephrosis and mass on posterior bladder wall. However, I-131 MIBG scan didn't showed abnormal uptake. He also underwent F-18 fluorodeoxyglucose (FDG) positron emission tomography/CT for localizing accurate tumor site. F-18 FDG PET/CT showed multiple metastases of left supraclavicular, hilar, mediastinal para-aortic, inguinal, right iliac lymph nodes, lung, vertebrae, and pelvis. There are a few reports showing that the F-18 FDG PET/CT is helpful for staging and localizing tumor site of patients who are diagnosed with negative on the MIBG scans. Thus, we report a case with paraganglioma which showed negative I-131 MIBG scan, but revealed multiple intense hypermetabolic foci in F-18 FDG PET/CT.

  7. Medically-derived I-131: a potential tool for understanding the fate of wastewater nitrogen in aquatic systems

    Rose, P. S.; Smith, J. P.; Aller, R. C.; Cochran, J. K.; Swanson, R. L.; Murthy, S. N.; Coffin, R. B.

    2010-12-01

    Iodine-131(t1/2 = 8 days) has been measured in Potomac River water and sediments in the vicinity of the Blue Plains Water Pollution Control Plant (WPCP), Washington, DC. The source of I-131 is medical, where it is commonly used to treat thyroid cancer and hyperthyroidism. Iodine is metabolized by patients and eliminated primarily in urine. While other medical radioisotopes may enter the environment via sewage effluent, the nature and quantity of treatments using I-131 cause it to account for much of the radioactivity in sewage effluent. Natural iodine in aquatic systems is biologically cycled similar to other nutrients, such as nitrogen. Iodine-131 concentrations measured in sewage effluent from Blue Plains WPCP and in the Potomac River suggest a relatively continuous discharge of this isotope. Dissolved I-131 shows a strong, positive correlation with δ15N values of nitrate in the river. The range of I-131 concentrations detected in surface waters is 0.18 ± 0.01 to 0.68 ± 0.02 Bq/L. Surface water δ15NO3 values ranged from 8.7 ± 0.3 to 33.4 ± 7.3 ‰ with NO3+NO2 concentrations between 0.38 ± 0.02 and 2.79 ± 0.13 mgN/L. Sediment profiles of particulate I-131 and δ15N indicate rapid mixing or sedimentation and in many cases remineralization of a heavy nitrogen source consistent with wastewater nitrogen. Iodine-131 concentrations in sediments ranged from 1.31 ± 0.8 to 117 ± 2 Bq/kg dry weight. Values of δ15N in sediments ranged from 4.7 ± 0.1 ‰ to 9.3 ± 0.1 ‰. We propose that I-131 coupled with δ15N can be an excellent tracer for the short-term fate of wastewater nitrogen in this system. However, the utility of I-131 as a tracer is not limited to use in the Potomac River. Other studies have documented the presence of I-131 in several aquatic systems and continuous discharges of this radioisotope in sewage effluent are likely to be widespread in urban environments.

  8. The Assessment of I-131 Internal Doses of Nuclear Medicine Workers in Korea Using Thyroid uptake system

    Bahn, Young Kag; Oh, Gi Back; Lee, Chang Ho; Lee, Jong Doo; Yeom, Yu Sun; Hwang, Young Muk

    2012-01-01

    There are possibilities the radiation workers could intake the radiation when workers deal with radiation-materials. Therefore, internal radiation doses of radiation workers need to be assessed. Although an application of the nuclear medicine is continuously increased in Korea, there is not a proper tool and form to monitor the internal doses of nuclear medicine workers. However, it is possible to attain the internal doses of I-131 to evaluate using thyroid uptake and well count system. In this study, we measured and evaluated the I-131 internal doses of nuclear medicine workers in Korea using thyroid uptake and well count system and performed an air sampling

  9. Lung uptake on I-131 therapy and short-term outcome in patients with lung metastasis from differentiated thyroid cancer

    Okamoto, Shozo; Shiga, Tohru; Uchiyama, Yuko; Manabe, Osamu; Kobayashi, Kentaro; Yoshinaga, Keiichiro; Tamaki, Nagara

    2014-01-01

    It is sometimes difficult to assess I-131 lung uptake at the initial I-131 therapy because of strong artifacts from I-131 uptake in the thyroid bed. The aim of this study was to analyze the lung uptake at the second I-131 therapy for lung metastasis in patients who did not have lung uptake at the initial therapy from differentiated thyroid carcinoma (DTC). Then, we also analyzed the relationship between the initial lung uptake and short-term outcome after I-131 therapies. This study included 62 DTC patients with lung metastasis. The patients were classified into 2 groups according to the lung uptake at the initial I-131 therapy such as patients with lung uptake (positive uptake group n=31) and those without lung uptake (negative uptake group n=31). The lung uptake was analyzed at the second therapy in both groups. The short-term outcome was also analyzed based on the CT findings of lung metastasis size and serum thyroglobulin level between the two groups. The positive uptake group showed positive lung uptake at the second therapy in 23 patients (74%), whereas none of negative uptake group showed any lung uptake at the second therapy (P < 0.01). The positive uptake group significantly decreased in the size of lung metastasis from the initial therapy to the second therapy (20.0 ± 11.7 to 16.6 ± 9.6 mm, P < 0.01) with further decrease after the second therapy (P < 0.05). The serum thyroglobulin level was also significantly decreased from the initial therapy to the second therapy (4348 ± 7011 to 2931 ± 4484 ng/ml, P < 0.05). In contrast, the negative uptake group significantly increased in the size of lung metastasis from the initial therapy to the second therapy (17.3 ± 12.2 to 19.9 ± 14.3 mm, P < 0.01) with further increase after the second therapy (P < 0.01). No patients without lung uptake at the initial I-131 therapy showed lung uptake at the second therapy, or showed treatment effect. Therefore, second I-131 therapy for these patients with initially

  10. Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131imaging

    Khosravi, H. R.; Sarkar, S.; Takavar, A.; Saghari, M.; Shahriari, M.

    2007-01-01

    Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based forced detection (CFD) method as a variance reduction technique was implemented into the well known SlMlND MC photon simulation software. A variety of simulations including point and extended sources in uniform and non-uniform attenuation media, were performed to compare differences between FD and CFD versions of SlMlND modeling for I 131 radionuclide and camera configurations. Experimental measurement of system response function was compared to FD and CFD simulation data. Results: Different simulations using the CFD method agree very well with experimental measurements as well as FD version. CFD simulations of system response function and larger sources in uniform and non-uniform attenuated phantoms also agree well with FD version of SIMIND. Conclusion: CFD has been modeled into the SlMlND MC program and validated. With the current implementation of CFD, simulation times were approximately 10-15 times shorter with similar accuracy and image quality compared with FD MC

  11. I-131 therapy for hyperthyroidism in carbimazole induced acute aplastic anaemia

    Jenkin, B.A.; Van Every, B.; Kelly, M.J.

    1998-01-01

    Full text: We present a case of a 39 year old previously well woman who developed carbimazole-induced acute aplastic anaemia. Following 6 weeks of carbimazole for Grave's disease she presented with fever, sore throat and lethargy and was found to be pancytopaenic. Haemoglobin fell to 79g/l (normal>120g/l), neutrophils to an undetectable level and platelets to 4,000/ml (normal>150,000/ml). From the MIRD schema it was estimated that a therapeutic dose of 444 MBq (12mCi) to treat her hyperthyroidism would deliver a red marrow radiation dose of about 30 mSv, at least an order of magnitude below any expected demonstrable deleterious effect on the marrow. Subsequently a dose of 444 MBq of I-131 was given and within 2 weeks the marrow had begun to recover, eventually to normal. This case would support the use of 1-131 for hyperthyroidism in carbimazole-induced marrow aplasia, even in profoundly depressed marrow

  12. Estimation dose in organs of hyperthyroidism patients treated with I-131

    Farias de Lima, F.; Khoury, H.C.; Bertelli Neto, L.; Hazin, C.

    1997-01-01

    Full text: The absorbed dose in organs of hyperthyroidism patients, which received 370 MBq and 555 MBq of I-131 were estimated, using the MIRDOSE computational program and data of the ICRP-53 publication. The calculus were done considering an equal uptake to 45% and an effective half life of 5 days, these values are closed to the average values found in 17 studied patients. The thyroidal masses were previously determined by the physicians and varied between 40 g and 80 g The results showed that the dose in the thyroid, for an activity of 370 MBq, varied between 99 Gy and 49,5 Gy for the masses of 40 g and 80 g respectively. In the case of the administration of 555 MBq the patients had thyroidal masses between 60 g and 80 g and the doses varied between 99 Gy and 74,2 Gy, respectively. These values showed that the absorbed doses in thyroid are within limits expected for the hyperthyroidism therapy, which are of 506 Gy to 100 Gy. The 100 Gy dose would be exceeded, if the patients with thyroidal mass of 40 g had received a therapeutic dose of 555 MBq. The estimated media doses in others organs were relatively low, with inferior values of 0,1 Gy in kidneys, bone marrow and ovaries and of 0,19 Gy in stomach

  13. I-131 therapy for hyperthyroidism in carbimazole induced acute aplastic anaemia

    Jenkin, B.A.; Van Every, B.; Kelly, M.J. [Alfred Hospital, Prahran, VIC (Australia). Nuclear Medicine Department

    1998-06-01

    Full text: We present a case of a 39 year old previously well woman who developed carbimazole-induced acute aplastic anaemia. Following 6 weeks of carbimazole for Grave`s disease she presented with fever, sore throat and lethargy and was found to be pancytopaenic. Haemoglobin fell to 79g/l (normal>120g/l), neutrophils to an undetectable level and platelets to 4,000/ml (normal>150,000/ml). From the MIRD schema it was estimated that a therapeutic dose of 444 MBq (12mCi) to treat her hyperthyroidism would deliver a red marrow radiation dose of about 30 mSv, at least an order of magnitude below any expected demonstrable deleterious effect on the marrow. Subsequently a dose of 444 MBq of I-131 was given and within 2 weeks the marrow had begun to recover, eventually to normal. This case would support the use of 1-131 for hyperthyroidism in carbimazole-induced marrow aplasia, even in profoundly depressed marrow

  14. Risk from ionizing radiation to the clinical staff and incidental public in the course of therapy with I-131

    Chas, J.; Janiak, M.K.; Kowalczyk, A.; Siekierzynski, M.; Dziuk, E.

    1997-01-01

    The aim of the study was to assess the risk to the personnel and neighbouring patients exposed to ionizing radiation during their stay at the Isotopic Therapy Clinic in Warsaw where therapeutic applications of I-131 are routinely performed. To this end, thermoluminescent dosimeters were deposited in various places throughout the Clinical ward and the absorbed doses were read after 125 days of the exposition. Additionally, exposure dose rates were determined at the skin surface over the thyroid gland at 0.5 and 1.0 m away from 71 patients treated with I-131 for hyperthyroidism or thyroid cancer (as a supplementary therapy after thyroidectomy) and the potential dose equivalents were calculated. From these values ''restriction times'', i.e., the amounts of time needed for the potential dose equivalents to decline below the limit recommended for occupational or public exposures to ionizing radiation were derived. The results indicate that - a) the probability to exceed the recommended annual dose limit by the personnel (50 mSv y -1 ) and neighbouring patients not subjected to radiotherapy (1 mSv y -1 ) during their exposition at the Isotopic Therapy Clinic to the I-131 treated patients is practically equal to zero; b) no restrictions in terms of limiting the duration of contact with the I-131-treated patients are necessary during the occupational exposures of the personnel of the Clinic; and c) the treated patients may incur some risk to the general public only when injected with high doses of I-131 and/or only within about 3 days upon the application of the radionuclide. (author)

  15. Maximal safe dose therapy of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    Lee, Jong Jin; Seok, Ju Won; Uh, Jae Sun

    2005-01-01

    In patients with recurrent or metastatic differentiated thyroid carcinoma, residual disease despite repetitive fixed dose I-131 therapy presents an awkward situation in terms of treatment decision making. Maximal safe dose (MSD) administration base on bone marrow radiation allows the delivery of a large amount I-131 to thyroid cancer tissue within the safety margin. We investigated the efficacy of MSD in differentiated thyroid cancers, which had persisted after conventional fixed dose therapy. Forty-six patients with differentiated thyroid carcinoma who had non-responsible residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. The postoperative pathology consisted of 43 papillary carcinomas and 3 follicular carcinomas. MSD was calculated according the Memorial Sloan Kettering Cancer Center protocol using blood samples. MSDs were administered at intervals of at least 6 months. Treatment responses were evaluated using I-131 whole body scan (WBS) and serum thyroglobulin measurements. Mean calculated MSD was 12.5±2.1 GBq. Of the 46 patients, 6 (13.0%) showed complete remission, 15 (32.6%) partial response, 19 (41.3%) stable disease, and 6 (13.0%) disease progression. Thus, about a half of the patients showed complete or partial remission, and of these patients, 14 (67%) showed response after a single MSD administration and 6 (29%) showed response after the second dose of MSD administrations. Twenty-nine patients (63%) experienced transient cytopenia after therapy, and recovered spontaneously with the exception of one. MSD administration is an effective method even in the patients who failed to be treated by conventional fixed dose therapy. MSD therapy of I-131 can be considered in the patients who failed by fixed dose therapy

  16. Comparison of I-131 MIBG scintigrapy and F-18 FDG PET in neuroblastoma

    Pai, M.; Lee, S.; Yoo, E

    2004-01-01

    The purpose of this preliminary study was to compare the utility of metaiodobenzylguanidine(MIBG) scintigraphy and F-18 FDG PET for the detection of primary and metastatic lesions of neuroblatoma. F-18 FDG PET and I-131 MIBG scan or SPECT were performed with in 1 month of each other in 4 patients (age: 4-5, all female) with known neuroblastoma after primary treatment. In 3 of 4 patients with confirmed neuroblastoma, FDG PET and MIBG scans were concordant for the presence or absence of diseased sites. In two cases, residual abdominal masses less than 1cm in which the X -ray computed tomography showed no change in tumor volume had a simultaneous negative uptake in both MIBG scan and FDG PET. In a patient with histologic evidence of bone marrow involvement, there was no skeletal uptake of both MIBG and FDG but Tc-99m HDP bone scan revealed disseminated bone marrow involvement, while a large mediastinal primary mass of this patient showed intense MIBG and FDG uptake. In one patient whose large abdominal mass of neuroblastoma failed to accumulate FDG, MIBG uptake in the tumor was intense. We concluded that FDG PET could reveal metabolic state of primary or residual neuroblastoma as much as MIBG in majority of our cases but it did not show any advantages over MIBG or even bone scan. FDG PET had an obvious defect in detection of residual viable disease in one patient. FDG PET may not replace MIBG or bone scan for evaluation of primary or metastatic disease of neuroblastoma in the diagnostic and staging procedure from INSS recommendation

  17. Comparison of I-131 MIBG scintigrapy and F-18 FDG PET in neuroblastoma

    Pai, M.; Lee, S.; Yoo, E [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2004-07-01

    The purpose of this preliminary study was to compare the utility of metaiodobenzylguanidine(MIBG) scintigraphy and F-18 FDG PET for the detection of primary and metastatic lesions of neuroblatoma. F-18 FDG PET and I-131 MIBG scan or SPECT were performed with in 1 month of each other in 4 patients (age: 4-5, all female) with known neuroblastoma after primary treatment. In 3 of 4 patients with confirmed neuroblastoma, FDG PET and MIBG scans were concordant for the presence or absence of diseased sites. In two cases, residual abdominal masses less than 1cm in which the X -ray computed tomography showed no change in tumor volume had a simultaneous negative uptake in both MIBG scan and FDG PET. In a patient with histologic evidence of bone marrow involvement, there was no skeletal uptake of both MIBG and FDG but Tc-99m HDP bone scan revealed disseminated bone marrow involvement, while a large mediastinal primary mass of this patient showed intense MIBG and FDG uptake. In one patient whose large abdominal mass of neuroblastoma failed to accumulate FDG, MIBG uptake in the tumor was intense. We concluded that FDG PET could reveal metabolic state of primary or residual neuroblastoma as much as MIBG in majority of our cases but it did not show any advantages over MIBG or even bone scan. FDG PET had an obvious defect in detection of residual viable disease in one patient. FDG PET may not replace MIBG or bone scan for evaluation of primary or metastatic disease of neuroblastoma in the diagnostic and staging procedure from INSS recommendation.

  18. Exposure of employees engaged on the production and quality control of radiopharmaceuticals labelled with Tc-99m and I-131

    Trtic, T.; Jovanovic, M.; Vranjes, S.; Vucina, J.; Vuksanovic, Lj.

    1995-01-01

    In this paper, the analysis is presented, of exposure control of employees in the Laboratory for radioisotopes, of the Vinca Institute of nuclear sciences, engaged in the production and quality control of the Tc-99m generator and radiopharmaceuticals labelled with Tc-99m and I-131. Effective doses equivalent (mSv) was measured by personal thermoluminescent dosimeter in the Laboratory for radiation and environmental protection each month. We calculated effective dose equivalents for each year in the period 1986-1990. Thirty one employees were analysed. They were separated into the groups both on the basis of radioisotope which they worked with and the kind of the professional work. The highest average effective doses equivalent were received in the group producing of Tc-99m generator (4-12.5 mSv) and in the group producing I-131 radiopharmaceuticals (3.55-13.73 mSv). (author)

  19. Autonomous Functioning Thyroid Nodule in a 4-year-old Male Child Treated with Radioiodine (I-131)

    Khare, Abhishek; Bhutani, Puneet; Chauhan, Suneel

    2013-01-01

    Autonomous functioning thyroid nodules that cause toxic manifestations (toxic adenomas) are benign monoclonal tumors characterized by their capacity to grow and produce thyroxine (T4) and triiodothyronine (T3) autonomously, i.e. in the absence of thyrotropin thyroid stimulating hormone. Toxic adenomas are a rare presentation of hyperthyroidism in the pediatric population. Radioiodine (I-131) has been widely used for therapy of patients with toxic adenomas and is now accepted as a safe and effective treatment even in the pediatric age group. The authors here present a case of a 4-year-old boy with a solitary hyperfunctioning thyroid nodule, who was successfully treated with radioiodine (I-131) and is presently on follow-up

  20. Evaluation of absorbed dose in studies of renal function due to 123I/131I (hippuran) e 111In (DPTA)

    Vasquez, M.V.; Castillo, C.E.; Rojas, R.; Cabrera, C.; Abanto, D.; Morgan, A.; Diaz, E.E.

    2015-01-01

    The absorbed dose of the kidneys during renal function studies of adult patients is estimated through biokinetics of radiopharmaceuticals containing the 123 I/ 131 I (hippuran) e 111 In (DPTA). Using the methodology MIRD and representation Cristy-Eckerman for adult kidneys, it is shown that dosimetric contributions of organs of biokinetics 123 I/ 131 I (hippuran) e 111 In (DPTA) are significant, in estimative of dose for renal function studies. Dosimetric contributions (body and whole bladder, kidneys excluding) are given by 11.90% (for 123 I), 4.97% (for 131 I) and 28.32% (for 111 In). In all cases, the dosimetric contributions are mainly due to photons issued by the whole body

  1. Role of trophallaxis in the dispersal of radioactive I131 and of bacterial infections in the termite, Bifiditermes beesoni

    Khan, K.I.; Jafri, R.H.; Ahmad, M.

    1981-01-01

    Dispersal and localisation of radioactive iodine (I 131 ) through trophallaxis was studied in various organs of healthy or bacteria-infected pseudergates of Bifiditermes beesoni. The breakdown of the defence system by bacterial pathogens was also studied by means of I 131 . Individual groups of pseudergates of B. beesoni were infected by various bacterial pathogens, i.e. Thuricide-HP (commercial preparation of Bacillus thuringiensis), B. thuringiensis 11-toumanoffi, B. thuringiensis serotype 3a, 3b, Pseudomonas fluorescens and Serratia marcescens, respectively. Healthy pseudergates retained more radioactivity in their guts and less in their exoskeletons. However, bacteria-infected 'donor' and 'recipient' pseudergates and soldiers retained less radioactivity in their guts and more in their exoskeletons. The flow of radioactivity from gut towards exoskeleton or other parts of B. beesoni pseudergates occurred after destruction and breakdown of the inestinal defence system of the host. (orig.) [de

  2. Um índice de capacidade para especificações unilaterais

    Barriga,Gladys D. Cacsire; Ho,Linda Lee; Borges,Wagner Sousa

    2003-01-01

    Nos últimos anos, índices de capacidade de processos têm sido usados freqüentemente para determinar se um processo é capaz de produzir itens em conformidade com a tolerância especificada. No entanto, poucos estudos têm sido feitos acerca de índices de capacidade para situações em que há apenas um limite de especificação. Neste trabalho, um índice para situações em que há apenas um limite de especificação é apresentado. Ele é invariante com respeito à fração não-conforme do processo e "calibra...

  3. Guide for the putting int practice the control of internal contamination due to I-131 in hospitals

    1988-01-01

    The generalized use of radioactive installations in different branches of the Economy and Medicine makes essential the existence of a radiological surveillance systems that guarantees that exposure are kept within the limits established. Nuclear medicine workers in hospitals that handle I-131 constitutes a professional group that can be internally contaminated the aim of this guide is to give the entity the general instructions and the necessary methodology to fulfill the control of the internal contamination by this radionuclide

  4. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  5. Off-shore contamination by I-131 and Cs-137 from the Fukushima Daiichi nuclear power station accident

    Pereira, Wagner de Souza; Kelecom, Patrick Vicent; Miyashita, Erika; Universidade Federal Fluminense; Kelecom, Alphonse

    2011-01-01

    On March 11, 2011 the biggest earthquake ever registered in Japan severed off-site power supply to the Fukushima Daiichi Nuclear Power Station. Backup diesel generators began providing electricity to pumps circulating coolant to the reactors, but were knocked out by a large tsunami and the nuclear site lost the ability to maintain proper reactor cooling. This was the beginning of a huge nuclear accident that was assigned an INES maximum rating of 7. On March 21, Japanese authorities reported that the Tokyo Electric Power Company (TEPCO) had detected radioactive materials in seawater. Radioactivity started to be measured by the Japan Atomic Energy Agency every two days in sea water from eight locations, 30km from the coastline. I-131 and Cs-137 were analyzed among other radionuclides. It is the aim of this paper to gather all this information and to discuss the evolution of the radioactive marine contamination during the first month of the accident. Results indicate for surface seawater concentrations ranging from 24.9 to 161.0 Bq/L for I-131 and 11.2 to 186.0 Bq/L for Cs-137, and for deep waters of 1.59-15.0 Bq/L (I-131) and 0.0-11.4 Bq/L (Cs-137). The I-131 concentrations in superficial waters were at or above Japanese regulatory limits in the first days, then lowered during one week to increase again above limits when TEPCO released contaminated water into the ocean, to finally reach not detectable values the last week of April. With the exception of point 4, on April 15, the Cs-137 levels were always well below regulatory limits. (author)

  6. Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    Lee, Jong-Jin; Chung, June-Key; Kim, Sung-Eun; Kang, Won-Jun; Park, Do-Joon; Lee, Dong-Soo; Cho, Bo-Youn; Lee, Myung-Chul

    2008-01-01

    The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. Forty-seven differentiated thyroid carcinoma patients with non-responsive residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. Their postoperative pathologies were 43 papillary carcinomas and 4 follicular carcinomas. The MSD was calculated with the Memorial Sloan-Kettering Cancer Center protocol using serial blood samples. The MSDs were administered at intervals of 6 months. Treatment responses were evaluated using I-131 whole-body scans and serum thyroglobulin measurements. The mean calculated MSD was 12.5±2.1 GBq (339.6±57.5 mCi). Of the 46 patients, 7 (14.9%) showed complete remission, 15 (31.9%) partial remission, 19 (40.4%) stable disease, and 6 (12.8%) disease progression. Of the patients who showed complete or partial remission, 15 (65%) showed response after the first MSD session and 6 (26%) showed response after the second session. Twenty-nine patients (62%) experienced transient cytopenia after therapy, but three did not recover to the baseline level. The maximal safe dose provides an effective means of treatment in patients who failed to respond adequately to conventional fixed dose therapy. I-131 MSD therapy can be considered in patients who fail fixed dose therapy. (author)

  7. Iodine capsules in thyroid therapy: An individually controlled study of I-131 uptake kinetics as compared to liquid administration

    von Schulthess, G.K.; Seelentag, W.W.; Pfeiffer, G.; Blauenstein, P.; Bekier, A.

    1984-01-01

    The aim of this study was to determine the additional radiation dose sustained by parts of the patients gastric mucosa when given I-131 therapy in capsular rather than liquid form, and thus to establish the safety of this procedure. 16 patients with benign thyroid disease were studied by measuring serum radioactivity at 0, 5, 10, 20, 40, and 80 min. after administration of the capsule (120-200 MBq I131). These serum uptake values were compared to the uptake after administration of a liquid diagnostic dose of I-131 (2 MBq). From the resulting uptake curves the delay due to capsular dissolution was determined. The average dissolution time was found to be 12 min. with a large standard deviation of 7 min. Also, a theoretical curve was computed to indicate the dose rate as a function of the distance from the surface of the capsule. Based on this information the maximum dose to the gastric mucosa is of the order of 250 cGy for a therapeutic activity of 185 MBq, which is the maximum dose which may be given as single application to outpatients in Switzerland. By having the patient swallow some liquid during the first ten minutes, the capsule can be made to move around, and hence, the local radiation dose can be reduced substantially. The authors conclude, that I-131 in capsular form is a safe galenic form for therapeutic use in patients with thyroid disease. When large doses are given, administration of the dose in several capsules may be advisable

  8. A False Positive I-131 Metastatic Survey Caused by Radioactive Iodine Uptake by a Benign Thymic Cyst

    Avneet K. Singh

    2017-01-01

    Full Text Available Thyroid carcinoma is the most common endocrine malignancy in the United States with increasing incidence and diagnosis but stable mortality. Differentiated thyroid cancer rarely presents with distant metastases and is associated with a low risk of morbidity and mortality. Despite this, current protocols recommend remnant ablation with radioactive iodine and evaluation for local and distant metastasis in some patients with higher risk disease. There are several case reports of false positive results of metastatic surveys that are either normal physiologic variants or other pathological findings. Most false positive findings are associated with tissue that has physiologic increased uptake of I-131, such as breast tissue or lung tissue; pathological findings such as thymic cysts are also known to have increased uptake. Our case describes a rare finding of a thymic cyst found on a false positive I-131 metastatic survey. The patient was taken for surgical excision and the final pathology was a benign thymic cyst. Given that pulmonary metastases of differentiated thyroid cancer are rare, thymic cysts, though also rare, must be part of the differential diagnosis for false positive findings on an I-131 survey.

  9. Radioiodine (I-131) application in the management of differentiated thyroid cancer (DTC) audit

    Nanayakkara, D.

    2005-01-01

    Full text: Differentiated thyroid cancer (DTC) remains one of the curable of all cancers. All literature reviews and clinical experiences regarding I 131 use in DTC conclude the beneficial effects, better prognosis, longer survival time and an assurance for cure. The Overall prognosis of patients with DTC is excellent if treat scientifically, adequately and timely. The management of thyroid cancer depends on the resources available in different institutions. Nuclear Medicine unit (NMU), Faculty of Medicine Peradeniya, Sri Lanka is in the process of uplifting the services for thyroid cancer management. Clinical audit was carried out in NMU on patients who utilized the Nuclear Medicine facilities in the management of DTC. It is important to identify deficiencies in current practice to improve our services. During January 2004 to March 2005, 126 DTC patients were referred for radioiodine Whole body scan (WBS) and therapy. Their age, sex, histology, extent of surgery, adequacy of thyroxine suppression treatment, monitoring with serum thyroglobulin levels (Tg), WBS results and radioiodine therapy were analyzed. There were 104(82.5%) females and 22(17.5%) males giving sex ratio of 4.7: 1. The Mean age was 35.5 years (range 9-58 years). The commonest histological types were papillary carcinoma 55.5% (n=70), follicular carcinoma 35% (n=44) and follicular variant of papillary carcinoma 9.5% (n=12). Seventy five percent (n=95) had total thyroidectomy (TT), 17 %(n=21) had near total thyroidectomy (NTT) and 8%(n=10) had subtotal thyroidectomy (STT). Sixty-nine patients (54.8%) were on thyroid suppression therapy. Thirty-six patients (28.6%) were referred to the WBS soon after surgery without initiation of thyroxine treatment. Another twenty-one patients (16.6%) were not on thyroxine therapy since surgery. Serum thyroglobulin was assessed on 20.6% (n=26). WBS done using 3-4 mCi liquid radioiodine showed residual functioning thyroid tissues in 41% (n=52). Lymph nodes or bone

  10. No hypothyroidism after I-131 therapy in pts with toxic nodular goiter, treated under combined thyreostatic, thyreomimetic medication

    Giubbini, R.; Panarotto, M.B.; Paghera, B.; Pagliaini, R.; Pajoro, U.; Pizzocaro, C.; Rossini, P.L.; Terzi, A.; Maira, G.

    2002-01-01

    Background. Treatment of toxic nodular goiter with 131-I is generally satisfactory and will cause a reversion of hyperthyroidism. To avoid the risk of thyrotoxic storm I-131 therapy is usually performed after pre-treatment with antithyroid drugs, which causes a TSH increase and functional recruitment of previously inhibited normal thyroid tissue. In this functional state both autonomous nodule(s) and normal tissue are irradiated after I-131 administration. This may be the reason of late hypothyroidism occurring in 15-25% of Pts. Aim of the study was the evaluation of a different pre-treatment modality with combined methimazole (10-20 mg) and Triiodo-thyronine (T3 - 60 μg) in order to treat pts in euthyroid state with suppressed TSH. Study protocol. After diagnosis of hyperthyroidism with autonomous functioning tissue the pts were put under thyreostatic medication. Two months later TSH was checked and if >0.5% U.I the T3 treatment was associated. After two more months, the TSH level was checked again and, if suppressed, the pt received I-131 therapy. Study population. 93 pts (74f, 19m - age 75±10) were consecutively enrolled. 24 pts had a toxic nodular goiter and 69 a multi nodular one, respectively; they were evaluated at diagnosis, at pre-treatment, two months after therapy and at late follow-up (3.1 ± 3.5 yrs). Methods: 557±225 MBq of I-131 (according to uptake determinations and gland weight) were administered. Methymazole was discontinued 3 days before treatment whereas T3 was maintained during I-131 therapy. Results: Euthyroidism was achieved after the first treatment in 71% of pts. At late follow-up TSH values over the normal range were observed in only 4 pts (4.3% - however all 4 pts had TSH level below 6 I.U.). Summaries of FT3 and FT4 values are presented. Conclusions: The treatment of toxic nodular goiter under combined thyreostatic-thyreomimetic treatment is a safe, well tolerated and effective procedure allowing a 71% success at the first treatment

  11. Fallout and drinking water contamination by I-131 and Cs-134, 137 in Japan, from the Fukushima Daiichi NPS accident

    Kelecom, Alphonse; Miyashita, Erika; Kelecom, Patrick Vicent

    2011-01-01

    The earthquake followed by a tsunami in Japan, on last March 11, seriously damaged four of the six reactors of the Fukushima Daiichi nuclear power station (NPS). Radioactive smokes and highly contaminated water were released for weeks to the environment. Since March 12, when the plant operator TEPCO and Japan's nuclear agency (NISA) confirmed the presence of radionuclides near the NPS, a giant environmental monitoring operation was set up, covering the entire Japanese territory. Daily thousands measurements are realized. We here analyze data released during 60 days on I-131 and Cs-134,137 radioactive concentrations in drinking water and fallout for 45 prefectures. Miyagi and Fukushima, that requires a separate study, are not considered here. Drinking water contamination by I-131 was observed in 13 prefectures, including Tokyo. The most impacted one was Tochigi (maximum of 110 Bq/l, March 24). This value turned water not drinkable for infants and babies. Cs-137 was detected in drinking water in 8 prefectures, with a maximum level of 18 Bq/l in Ibaraki. These levels do not affect potability of tap water. I-131 was observed in fallout in 27 prefectures, with level reaching 93 kBq/m2 in Ibaraki and 36 kBq/m 2 in Tokyo on March 21 and 23 respectively. Fallout of Cs-137 was observed in 19 prefectures. The maximum deposition occurred again in Ibaraki (13kBq/m 2 , March 21) and in Tokyo (5.3 kBq/m2, March 22). Since mid April, only trace contamination has been observed for both radionuclides in drinking water. Sporadically medium levels of Cs-137 are still observed in fallout. (author)

  12. Fallout and drinking water contamination by I-131 and Cs-134, 137 in Japan, from the Fukushima Daiichi NPS accident

    Kelecom, Alphonse; Miyashita, Erika; Kelecom, Patrick Vicent [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2011-07-01

    The earthquake followed by a tsunami in Japan, on last March 11, seriously damaged four of the six reactors of the Fukushima Daiichi nuclear power station (NPS). Radioactive smokes and highly contaminated water were released for weeks to the environment. Since March 12, when the plant operator TEPCO and Japan's nuclear agency (NISA) confirmed the presence of radionuclides near the NPS, a giant environmental monitoring operation was set up, covering the entire Japanese territory. Daily thousands measurements are realized. We here analyze data released during 60 days on I-131 and Cs-134,137 radioactive concentrations in drinking water and fallout for 45 prefectures. Miyagi and Fukushima, that requires a separate study, are not considered here. Drinking water contamination by I-131 was observed in 13 prefectures, including Tokyo. The most impacted one was Tochigi (maximum of 110 Bq/l, March 24). This value turned water not drinkable for infants and babies. Cs-137 was detected in drinking water in 8 prefectures, with a maximum level of 18 Bq/l in Ibaraki. These levels do not affect potability of tap water. I-131 was observed in fallout in 27 prefectures, with level reaching 93 kBq/m2 in Ibaraki and 36 kBq/m{sup 2} in Tokyo on March 21 and 23 respectively. Fallout of Cs-137 was observed in 19 prefectures. The maximum deposition occurred again in Ibaraki (13kBq/m{sup 2}, March 21) and in Tokyo (5.3 kBq/m2, March 22). Since mid April, only trace contamination has been observed for both radionuclides in drinking water. Sporadically medium levels of Cs-137 are still observed in fallout. (author)

  13. Outcomes of pregnancy in function of radiation dose to ovaries following a treatment with I131 for a differentiated thyroid cancer

    Garsi, J.P.; Rubino, C.; Labbe, M.; Vathaire, F. de; Garsi, J.P.; Schlumberger, M.; Rubino, C.; Ricard, M.; Labbe, M.; Vathaire, F. de; Garsi, J.P.; Rubino, C.; Labbe, M.; Vathaire, F. de; Schvartz, C.; Henri-Amar, M.; Bardet, S.; Ceccarelli, C.

    2008-01-01

    Radiations are mutagen. During a treatment for a differentiated cancer of thyroid, the minimal activity of I 131 given to the patient is 3700 MBq producing a radiation dose to ovaries estimated to 140 mGy. In spite of the importance of this dose, few data on the outcomes of the pregnancy after irradiation are available. After our study it appears that the exposure to I 131 has no harmful effect on the outcomes of these pregnancies. (N.C.)

  14. Estimation of parameters biokinetics from the resolution of a model compartment for I-131. Application to a patient with thyroid carcinoma hemodialysis

    Garcia, R.; Jimenez Feltstrom, D.; Luis dimon, F. J.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-01-01

    This work aims to define a biokinetic model for the I-131, and solve it for different conditions of the patient or person affected (normal, with cancer of the thyroid or hyperthyroid). Solve the model in the case of a patient treated with I-131 for ablation of thyroid remnants with undergoing renal insufficiency and hemodialysis . Get the parameters Biokinetic this model for different situations. (Author)

  15. Evaluation of absorbed dosis during studies of renal function due AI 123I / 131I (Hippuran) and 111 In (DPTA)

    Arteaga, Marcial V.V.; Diestra, Carlos E.C.; Villanueva, Raul A.S.; Alegria, Roberto R.; Salvatierra, Carlos C.; Rosales, Jorge M.; Gonzalez, Denis A.; Cruz, Carlos A.M.

    2014-01-01

    Using the MIRD methodology and Cristy-Eckerman representation for for adult kidneys, it proves that the dosimetric contributions of bodies of the biokinetics of 123 I / 131 I (Hippuran) and 111 In (DTPA) are significant, in the estimated of dose, during studies of renal function. Dosimetric contributions (whole body and urinary bladder, kidney excluding) are given by 11.90% (for 123 I), 4.97% (for 131 I) and 28.32% (for 111 In). In all cases, the dosimetric contributions are mainly due to photons emitted by the entire body

  16. Our first experience in the application of I-131 MIBG in a patient with neuroblastoma (A case report)

    Samarina, G.; Poksi, A.

    2005-01-01

    Full text: Neuroblastomas (NB) belong to a group of neuroendocrine tumors that are thought to arise from cells in the neural crest from the pelvis to neck, produce high levels of the urinary catecholamines vanillylmandelic acid (VMA) or homovanillic acid (HVA) in more than 90% of cases, and often metastasize to bones, bone marrow (BM), lymph nodes, and the liver. I-123 MIBG and I-131 MIBG are clinically important radiopharmaceuticals, which are routinely used for diagnostic imaging and treatment of NB. 90% percent of NB takes up the MIBG. If, however, the MIBG cannot successfully attach to a patient's tumor, it cannot be used to find or treat it. A 20-month-old girl presented with a 6-month history of a rapidly growing tumor mass 3.5 cm in diameter in the left orbital region. The first CT scan revealed a soft tissue tumor 22 x 28 mm, extending from the inferolateral wall of the left orbit and destroying the surrounding bone (os zygomaticus). CT scans of the chest and abdomen were negative. Histopathology showed high malignancy (G3) of NB (immunohistochemical reactions: NSE positive, CgA positive, SY positive, Ki-67 70% of tumor cells positive). First BM histological examination revealed no pathological findings. Urinary VMA and HVA levels were within the normal range. Tc-99m MDP scans showed increased uptake of radiopharmaceutical in the bones around the left orbital region but no evidence of skeletal metastases. 123 I-MIBG studies revealed a hypermetabolic focus in the left orbital region, concordance with the CT and bone scans. The child was treated with preoperative chemotherapy, but without any results: the CT-scan performed four months later showed that the tumor had grown to 45 x 37 x 40 mm. The clinical test demonstrated the progress of the disease and the tumor at that stage was inoperable. Clinicians decided to change the chemotherapy regimen and a CT study carried out three months later showed that the tumor had decreased to 26 x 10 x 30 mm. The patient

  17. Radiation Dose to Family Member of Hospitalized Patient Receiving I-131 Therapy for Thyroid Cancer: Case Study

    Tuntawiroon, M; Chaudakshetrin, P; Sritongkul N; Thongprapal, T

    2009-07-01

    Full text: During high-dose I-131 therapy, hospitalized patient who is unable to walk to the bathroom is at risk of radiation burden to comforter from excreted urine. Foley catheter is usually placed in the patient before I-131 administration. The urine was collected and housed in lead shielding, emptied every 4 to 6 hours on the first day, and every 8 to 10 hours on subsequent days. After specific instructions with regard to radiation safety, family member designed as the caregiver of patient was provided an electronic personal dosimeter to directly measure radiation dose for three days in isolated hospitalization and two more weeks at home. The caregiver recorded time spent in contact with the patient and activities performed during these times. Total accumulative dose for 16 days was 650 μSv of which 44% (288 μSv) was from the first 24 hours and more than 70% (462 μSv) during the first 72 hours, and about 25% (162 μSv) from emptying urine bags. Most of the dose received (488 μSv) was from attending time spent in the vicinity of the patients. However, this was not exceeding the constraints of 1 mSv/y and well below the limit of 5 mSv in any one year for exposed caregiver and comforter

  18. Evaluation of detectors for blood bioanalysis in Lu-177 and I-131 therapies for bone marrow dosimetry

    Degenhardt, Amilie Louize

    2016-01-01

    The measures traceability is mandatory for minimizing uncertainties in internal dosimetry for radiopharmaceuticals clinical studies and ensures the quality of the standard. Equipment should have resolution and efficiency compatible with radionuclides energies and, additionally, be able to quantify variations in human bodies' activities samples since the initial administration near the minimum residual activities. For testing three equipment (ionization chamber Capintec 25R, sodium iodine scintillator LTI Genesys Gamma-1 and high hyperpure germanium detector Canberra), they were prepared Lu-177 and I-131 radiation sources simulating patient's blood samples activities by adopting the following hypothesis: (1) initial activities according the Brazilian protocols; (2) blood volume in the whole body (5.3 L for adult men and 1.4 L for 5 years-old children); (3) effective half-lives (1.61 h and 42.9 h for Lu-177 bi-exponential adjustment and 15.7 h for I-131 mono-exponential adjustment); (4) sampling between 30 min and 168 h; (v) blood density adjustments. The standard sources were measured in the secondary standard ionization chamber Centronics IG11 at the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes. The Capintec ionization chamber efficiencies ranged, respectively for I-131 and Lu-177, between (111.58±0.02)% and (102.27±0.01)% and HPGe semiconductor detector efficiencies ranged, respectively, between (89.40±0.03)% and (87.80±0.04)%. For the NaI detector, when the Lu-177 sources were positioned inside the detector the efficiencies ranged between (12.66±0.01)% and (11.54± 0.07)% and when the sources were positioned at 5 cm and 10 cm from the detector the efficiencies decreased to less than 5%. For I-131 sources positioned inside the detector, the efficiencies ranged between (29.76±0.21)% and (30.20±0.04)% and they decreased to less than 5% when they were positioned at 5 cm and 10 cm from the detector (deviation greater than 95

  19. Study on the change of hepatic fibrosis indicators in serum before and after I-131 treatment in Graves' Patients

    Li, L.

    2007-01-01

    Full text: Objective: To explore the change of hepatic fibrosis indicators, i.e., PC-III (type III procollagen), IV-C (type IV collagen), HA (hyaluronic acid), LN (laminin) levels in serum of Graves' patients before and after I-131 treatment. Methods: Control group were 40 healthy cases (female 25, male 15, aged 18-60 years) with normal serum levels of those indicators by medical examination in our hospital. Fifty-five Graves' patients (female 32, male 23, aged 17-58) were diagnosed by thyroid function indicators (TT3, TT4, FT3, FT4, TSH) tests, thyroid iodine intake and clinical symptoms and signs, with normal hepatic function indicators and without combined history of hepatic disease, cardiac disease, diabetes, and rheumatic disease. Three to six months after I-131 treatment these were completely recovered (back to normal thyroid function, shrunken thyroid gland volume from swelling, and disappeared clinical symptoms and signs). In both controls and Graves' patients, 2 ml venous blood was taken at early morning from each case with limosis respectively before and after I- 131 treatment. RIA method was adopted for detection of each serum indicator with reagents kit. Data were analyzed by t test in the SPSS statistical software pack. Results: 1. In Graves' patients, before treatment PC- III (type III procollagen) levels were statistically higher than that in controls (p 0.05). 2. In Graves' patients, PC-III significantly decreased to a lower level after treatment than before (p 05). 3. In Graves' patients, after treatment there is no significant difference of indicator levels when compared with controls (p>0.05). Conclusion: Graves' patients had certain degree of hyperplasia of hepatic connective tissue, and this pathogenesis recovered with healing of Graves' disease. PC-III positive rate and thyroid function indicator positive rate may be better in accordance with the disease process than IV-C, Ha and LN indicators. These data showed that of four serum hepatic

  20. Adjuvant thyroid remnant ablation in patients with differentiated thyroid carcinoma confined to the thyroid. A comparison of ablation success with different activities of radioiodine (I-131)

    Prpic, M.; Dabelic, N.; Stanicic, J.; Jukic, T.; Kusic, Z.; Milosevic, M.

    2012-01-01

    The objective of this study was to assess efficiency of various I-131 activities on thyroid remnant ablation in thyroid cancer patients. The significance of patients' characteristics, pathologic features and levels of Tg were analyzed. This study included 259 consecutive differentiated thyroid cancer patients, with disease confined to the thyroid, treated with I-131 after total thyroidectomy. Patients were divided into the three groups: 80 patients receiving low [1110-1850 MBq (30-50 mCi)], 121 intermediate [2775 MBq (75 mCi)] and 58 high [3700 MBq (100 mCi)] postoperative I-131 activities. Six to eight months after the application of radioiodine, measurements of TSH, Tg, anti-Tg antibodies (in hypothyroid state) together with ultrasound exam and whole-body scintigraphy were performed. The ablation was significantly more effective (after the first application) in patients receiving 100 mCi of I-131-89.7% than in patients receiving lower activities (P=0.016). There was no significant difference in ablation rate between the 30-50 mCi (77.5%) and 75 mCi (70.2%) groups. In the group receiving 30-50 mCi, patients with solitary tumors had significantly higher ablation rate (P=0.038). In patients receiving 75 mCi ablation rates were higher among older patients (P=0.005), with infiltration of the single lobe (P=0.005), and with solitary tumor (P=0.012). The rates of successful ablation after the second application of I-131 (after 12-16 months) amounted to 96, 97 and 96% in the 30-50, 75 and 100 mCi groups, respectively. The activity of I-131 and age were independent factors for thyroid ablation failure after the first application of I-131 (model of binary logistic regression). The results of remnant ablation were satisfactory with all activities applied. Although after the first application of I-131 the activity of 100 mCi is significantly more effective in thyroid ablation than the administration of 30-50 mCi and 75 mCi, the ablation rates between all the three groups are

  1. Model of iodine metabolism in a T3-thyrotoxic patient undergoing I-131 therapy

    Ahuja, S.; Price, R.; Brill, A. B.; Dobyns, B. M.; Berman, M.

    1975-06-01

    Data on radioactivity in the thyroid, urine, serum, butanol-extractable iodine (BEI) and chromatographic fractionations of BEI, obtained during four I-131 therapeutic treatments of a T3-thyrotoxic patient, have been analyzed and simulated with the help of a 7-compartment model. Good fits to most of the data can be obtained with both the dose-independent and dose-dependent models. A model with 3 or 4 compartments, which provides adequate fits to iodine kinetic data in most euthyroid and hyperthyroid patients is not satisfactory in the case of this patient. Thus, to represent iodine metabolism during T3-thyrotoxicosis therapy, we find that it is necessary to provide for separate biochemical pathways for the BEI components as well as the butanol-insoluble compounds released by the thyroid gland. (auth)

  2. Reproductive function and biological dosimetry prospective study of young thyroid differentiated cancer patients treated with I-131

    Di Giorgio, M.; Vallerga, M.B.; Taja, M.R.; Radl, A.; Chebel, Graciela; Fadel, Ana Maria; Gutierrez, Silvia; Normandi, Eduardo; Levalle, Oscar; Kundt, Miriam

    2011-01-01

    The administration of I-131 in the management of differentiated thyroid cancer (DTC) is a well established practice. As the spermatogonia is highly sensitive to radiation, large doses of internal radiation could result in adverse effects on reproductive function such as oligo/azoospermia and infertility. During spermiogenesis, mammalian chromatin undergoes replacement of nuclear histones by protamines, which yields a DNA sixfold more highly condensed in spermatozoa than in mitotic chromosomes. The structure of this highly packaged chromatin shows a low binding capacity for several fluorochromes and dyes such as chromomycin A3 (CMA3). The aim of this study is to assess the correlation between reproductive function (endocrine and exocrine testicular function, and levels of CMA3 stainability) and biological dosimetry in a prospective study of 4 young DTC patients treated with I-131. In this context, a background level of CMA3 binding in mature human sperm was established. It revealed a variable accessibility of CMA3 to the DNA that is dependant on packaging quality and thus, indicative of protamine deficiency. The identification of altered stainability suggests DNA damage as well as epigenetic effects, which may be indicators of male infertility. Transient impairment of spermatogenesis associated with an increase in FSH, an altered spermiogram and even azoospermia was observed after the administration of cumulative activities. Overall, testosterone levels were preserved, except in one case, which presented a drastically diminished value associated with an increase in LH level. As peripheral blood lymphocytes and spermatogonia have equivalent radiosensitivity (interphase death) we hypothesize that the knowledge of DNA damage recovery in peripheral lymphocytes could correlate with spermatogonia recovery and with FSH evolution. (authors)

  3. Reproductive function and biological dosimetry prospective study of young thyroid differentiated cancer patients treated with I-131

    Di Giorgio, Marina; Vallerga, Maria B.; Taja, Maria R.; Radl, Analia; Chebel, Graciela; Fadel, Ana M.; Gutierrez, Silvia; Normandi, Eduardo; Levalle, Oscar; Kundt, Miriam

    2008-01-01

    Full text: The administration of I-131 in the management of differentiated thyroid cancer (DTC) is a well established practice. As the spermatogonia is highly sensitive to radiation, large doses of internal radiation could result in adverse effects on reproductive function such as oligo/azoospermia and infertility. During spermiogenesis, mammalian chromatin undergoes replacement of nuclear histones by protamines, which yields a DNA sixfold more highly condensed in spermatozoa than in mitotic chromosomes. The structure of this highly packaged chromatin shows a low binding capacity for several fluoro chromes and dyes such as chromo mycin A 3 (CMA 3 ). The aim of this study is to assess the correlation between reproductive function (endocrine and exocrine testicular function, and levels of CMA 3 stainability) and biological dosimetry in a prospective study of 4 young DTC patients treated with I-131. In this context, a background level of CMA 3 binding in mature human sperm was established. It revealed a variable accessibility of CMA 3 to the DNA that is dependant on packaging quality and thus, indicative of protamine deficiency. The identification of altered stainability suggests DNA damage as well as epigenetic effects, which may be indicators of male infertility. Transient impairment of spermatogenesis associated with an increase in FSH, an altered spermiogram and even azoospermia was observed after the administration of cumulative activities. Overall, testosterone levels were preserved, except in one case, which presented a drastically diminished value associated with an increase in LH level. As peripheral blood lymphocytes and spermatogonia have equivalent radiosensitivity (interphase death) we hypothesize that the knowledge of DNA damage recovery in peripheral lymphocytes could correlate with spermatogonia recovery and with FSH evolution. Therefore, a prospective study on the decline of unstable chromosome aberrations is being conducted, considering the damage

  4. RET/PTC and PAX8/PPARγ chromosomal rearrangements in post-Chernobyl thyroid cancer and their association with I-131 radiation dose and other characteristics

    Leeman-Neill, Rebecca J.; Brenner, Alina V.; Little, Mark P.; Bogdanova, Tetiana I.; Hatch, Maureen; Zurnadzy, Liudmyla Y.; Mabuchi, Kiyohiko; Tronko, Mykola D.; Nikiforov, Yuri E.

    2012-01-01

    Background Childhood exposure to I-131 from the 1986 Chernobyl accident led to a sharp increase in papillary thyroid carcinoma (PTC) incidence in regions surrounding the reactor. Data concerning the association between genetic mutations in PTCs and individual radiation doses are limited. Methods We performed mutational analysis of 62 PTCs diagnosed in a Ukrainian cohort of patients who were Chernobyl tumors and show different associations for point mutations and chromosomal rearrangements with I-131 dose and other factors. These data support the relationship between chromosomal rearrangements, but not point mutations, and I-131 exposure and point to a possible role of iodine deficiency in generation of RET/PTC rearrangements in these patients. PMID:23436219

  5. High-dose I-131 MIBG treatment for young children with high-risk neuroblastoma, and its practical problem. From the experience of the youngest case in Japan

    Araki, Raita; Nishimura, Ryosei; Mase, Shintaro

    2012-01-01

    High-dose I-131 MIBG (metaiodobenzylguanidine) therapy combined with auto- or allo-hematopoietic stem cell transplantation is becoming a potential treatment for patients with high-risk neuroblastoma worldwide. However, only older children, who can perform personal care, had been given high-dose I-131 MIBG treatment to avoid the needless radiation exposure to caregivers and medical staff in Japan. In this case report, we have used the high dose MIBG therapy followed by autologous PBSCT (peripheral blood stem cell transplantation) for a 1-year-old boy with a newly diagnosed high-risk neuroblastoma with MYCN amplifications. The total radiation exposure to all parties involved was very limited, even in the youngest case in Japan, probably due to adequate preparations. This encouraging experience may remove the age limit for high-dose I-131 MIBG treatment for the patients with high-risk neuroblastoma in Japan. (author)

  6. Daily variation of I-131, Cs-134 and Cs-137 activity concentrations in the atmosphere in Osaka during the early phase after the FDNPP accident

    Zijian Zhang; Kazuhiko Ninomiya; Naruto Takahashi; Atsushi Shinohara

    2015-01-01

    To investigate the time variations of radionuclides discharged from the Fukushima Daiichi nuclear power plants accident, we started collecting aerosol samples in Osaka, Japan, using a high-volume sampler from March 15 to May 1, 2011. Atmospheric radioactivity concentrations of I-131, Cs-134 and Cs-137 were measured with germanium semi-conductor detectors. Only I-131 was detected in the early phase and two Cs-134.137 peaks were found in Osaka in April. Using the HYSPLIT model, we concluded that direct transportation of the air mass from the Fukushima area was responsible for such events. (author)

  7. Comparison of internal dosimetry factors for three classes of adult computational phantoms with emphasis on I-131 in the thyroid

    Lamart, Stephanie; Simon, Steven L; Lee, Choonsik; Bouville, Andre; Eckerman, Keith F; Melo, Dunstana

    2011-01-01

    The S values for 11 major target organs for I-131 in the thyroid were compared for three classes of adult computational human phantoms: stylized, voxel and hybrid phantoms. In addition, we compared specific absorbed fractions (SAFs) with the thyroid as a source region over a broader photon energy range than the x- and gamma-rays of I-131. The S and SAF values were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms and the University of Florida (UF) hybrid phantoms by using the Monte Carlo transport method, while the S and SAF values for the Oak Ridge National Laboratory (ORNL) stylized phantoms were obtained from earlier publications. Phantoms in our calculations were for adults of both genders. The 11 target organs and tissues that were selected for the comparison of S values are brain, breast, stomach wall, small intestine wall, colon wall, heart wall, pancreas, salivary glands, thyroid, lungs and active marrow for I-131 and thyroid as a source region. The comparisons showed, in general, an underestimation of S values reported for the stylized phantoms compared to the values based on the ICRP voxel and UF hybrid phantoms and relatively good agreement between the S values obtained for the ICRP and UF phantoms. Substantial differences were observed for some organs between the three types of phantoms. For example, the small intestine wall of ICRP male phantom and heart wall of ICRP female phantom showed up to eightfold and fourfold greater S values, respectively, compared to the reported values for the ORNL phantoms. UF male and female phantoms also showed significant differences compared to the ORNL phantom, 4.0-fold greater for the small intestine wall and 3.3-fold greater for the heart wall. In our method, we directly calculated the S values without using the SAFs as commonly done. Hence, we sought to confirm the differences observed in our S values by comparing the SAFs among the phantoms with the thyroid as a

  8. Comparison of internal dosimetry factors for three classes of adult computational phantoms with emphasis on I-131 in the thyroid

    Lamart, Stephanie; Bouville, Andre; Simon, Steven L.; Eckerman, Keith F.; Melo, Dunstana; Lee, Choonsik

    2011-11-01

    The S values for 11 major target organs for I-131 in the thyroid were compared for three classes of adult computational human phantoms: stylized, voxel and hybrid phantoms. In addition, we compared specific absorbed fractions (SAFs) with the thyroid as a source region over a broader photon energy range than the x- and gamma-rays of I-131. The S and SAF values were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms and the University of Florida (UF) hybrid phantoms by using the Monte Carlo transport method, while the S and SAF values for the Oak Ridge National Laboratory (ORNL) stylized phantoms were obtained from earlier publications. Phantoms in our calculations were for adults of both genders. The 11 target organs and tissues that were selected for the comparison of S values are brain, breast, stomach wall, small intestine wall, colon wall, heart wall, pancreas, salivary glands, thyroid, lungs and active marrow for I-131 and thyroid as a source region. The comparisons showed, in general, an underestimation of S values reported for the stylized phantoms compared to the values based on the ICRP voxel and UF hybrid phantoms and relatively good agreement between the S values obtained for the ICRP and UF phantoms. Substantial differences were observed for some organs between the three types of phantoms. For example, the small intestine wall of ICRP male phantom and heart wall of ICRP female phantom showed up to eightfold and fourfold greater S values, respectively, compared to the reported values for the ORNL phantoms. UF male and female phantoms also showed significant differences compared to the ORNL phantom, 4.0-fold greater for the small intestine wall and 3.3-fold greater for the heart wall. In our method, we directly calculated the S values without using the SAFs as commonly done. Hence, we sought to confirm the differences observed in our S values by comparing the SAFs among the phantoms with the thyroid as a

  9. Radiation exposure from liquid discharges from I-131 therapy rooms into the piping system of a hospital building

    Tuntawiroon, M.; Sritongkul, N.; Pusuwan, P.; Chaudakshetrin, P.

    2008-01-01

    Over 80% of the activity from patients undergoing radioiodine therapy for thyroid cancer is eliminated during the first three days. In our I-131 therapy unit, the number of hospitalized patients has increased from less than 200 in 2004 to more than 300 in 2006. The total amount of radio activity used is about 1,800 GBq per year, and the estimated amount excreted is calculated to be about 1,500 GBq. This results in significant volume of contaminated liquid discharges into the piping system. In this study, we monitored external dose rates in non-radiation use areas adjacent to pipeline connections in the building to ensure that the dose to non-occupational workers who reside in offices below the unit does not exceed 1 mSv per year. Exposure rates in areas adjacent to the pipeline junction connections were measured periodically from April 2006 to February 2007 five floors below the therapy unit. The measurements were made inside the wall at contact with the junction, outside the wall and in hallways at 1 meter from the wall, using a GM detector or an ionization chamber. The results were recorded in μSv/h and the dose received was estimated for members of the public. Significant increases in dose rates were detected in three floors below the unit. They were 20--30, 10--30 and 5--15 μSv/h at contact with the pipeline connections, 9--15, 10--15 and 3--5 μSv/h outside the wall, and 3--6, 4--6 and 2--5 μSv/h in hallways on floors 1, 2 and 3 respectively. After appropriate wall shielding has been provided, dose rate outside the wall was reduced to 1.4 μSv/h, and to 0.5.3 μSv/h in hallways. By using an occupancy factor 1/4 for hallways, the calculated dose now meets the public dose limits of 1 mSv per year. Therapeutic application of I-131 for the treatment of thyroid cancer generates a significant amount of contaminated liquid waste into the sewers. These wastes originate mainly from toilets, showers, wash basins and floor drains. Although waste discharges can be

  10. False Positive Findings on I-131 WBS and SPECT/CT in Patients with History of Thyroid Cancer: Case Series

    Zeina C. Hannoush

    2017-01-01

    Full Text Available Introduction. Although whole body scan (WBS with I-131 is a highly sensitive tool for detecting normal thyroid tissue and metastasis of differentiated thyroid cancer (DTC, it is not specific. Additional information, provided by single photon emission computed tomography combined with X-ray computed tomography (SPECT/CT and by the serum thyroglobulin level, is extremely useful for the interpretation of findings. Case Presentation. We report four cases of false positive WBS in patients with DTC: ovarian uptake corresponding to an endometrioma, scrotal uptake due to a spermatocele, rib-cage uptake due to an old fracture, and hepatic and renal uptake secondary to a granuloma and simple cyst, respectively. Conclusions. Trapping, organification, and storage of iodine are more prominent in thyroid tissue but not specific. Physiologic sodium-iodine symporter expression in other tissues explains some, but not all, of the WBS false positive cases. Other proposed etiologies are accumulation of radioiodine in inflamed organs, metabolism of radiodinated thyroid hormone, presence of radioiodine in body fluids, and contamination. In our cases nonthyroidal pathologies were suspected since the imaging findings were not corroborated by an elevated thyroglobulin level, which is considered a reliable tumor marker for most well-differentiated thyroid cancers. Clinicians should be aware of the potential pitfalls of WBS in DTC to avoid incorrect management.

  11. Personalization of restrictions and recommendations for patients heated with I-131. Experience during two years (2000-2001)

    Rivas Ballarin, M. A.; Ruiz Manzano, P.; Hernandez Vitoria, A.; Lozano Flores, F.; Ortega Pardina, P.

    2002-01-01

    The aim of this study is to set criteria for discharging patients treated with I-131, bearing in mind their familiar, social and working status according to the new Spanish legislation on radiological protection and European Guides related to the subject. A mathematical development and a normal contact pattern are proposed to calculate the period of restriction Tcr on the behaviour of the patients, so that the dose to their family friends and colleagues, both in thyroid carcinoma and hyperthyroidism, is within the dose constraints established in the European Guide Radiation Protection following iodine-131 therapy (exposures due to auto-patient or discharged in-patients) published in 1998. This systems has been applied ruing the last two years in Hospital Clinico Universitario Lozano Blesa of Zaragoza where the mean dose rate at 1 meter was 16,6 μSv/h on the day of discharge, after being in hospital for about 48 hours. Some results obtained for the three types of treatment are presented. (Author)

  12. Preoperative F-18-FDG PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 whole body scans

    Byun, Byung Hyun; Urn, Sang Moo; Cheon, Gi Jeong; Choi, Chang Woon; Lee, Byeong Cheol; Lee, Guk Haeng; Lee, Yong Sik; Shim, Youn Sang

    2007-01-01

    We evaluated the diagnostic performance of FDG-PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 scan. All patients had total thyroidectomy and following I-131 ablation therapy. In the follow-up period, FDG-PET showed suspected cervical lymph nodes metastases and neck dissection was performed within 3 months after FDG-PET. It had shown for all patients the negative I-131 scan within 3 months before FDG-PET or negative I-131 scan during the period of cervical lymph nodes metastases suspected on the basis of FDG-PET, CT, or ultrasonography until the latest FDG-PET. Preoperative FDG-PET results were compared with the pathologic findings of lymph nodes specimens of 19 papillary thyroid carcinoma patients. Serum Tg, TSH, and Tg antibody levels at the time of latest I-131 scan were reviewed. The size of lymph node was measured by preoperative CT or ultrasonography. In 45 cervical lymph node groups dissected, 31 lymph node groups revealed metastasis. The sensitivity and specificity of FDG-PET for metastasis were 74.2% (23 of 31) and 50.0% (7 of 14), respectively. Except for patients with elevated Tg antibody levels, all patients showed the elevated serum Tg levels than normal limits at the TSH of =30uIU/ml. 8 lesions without suspected metastatic findings on FDG-PET revealed metastasis (false negative), and none of them exceeded 8mm in size (4 to 8mm, median= 6mm). On the other hand, 23 true positive lesions on FDG-PET were variable in size (6 to 17mm, median=9mm). FDG-PET is suitable for the detection of metastatic cervical lymph nodes in patients with recurrent papillary thyroid carcinoma. However, false positive or false negative should be considered according to the size of lymph node

  13. Comparison of radiolabeling efficiency of peptides containing the RGD domain using the Tc-99M and I-131 radioisotopes

    Sobral, Danielle V.; Cabral, Francisco Romero; Malavolta, Luciana

    2017-01-01

    Full text: Introduction: Radiolabeled peptides have become very important in nuclear medicine and oncology in recent years mainly because they represent the molecular basis for in vivo imaging and radiopharmaceutical therapy with high specificity and affinity for over expressed receptors in tumors (Thno 2(5):481-501, 2012 / Drug Discov. Today. 7:1224-1232, 2012). In this context, peptides containing the RGD domain which possess high affinity for the αvβ3 integrin receptor have become an important tool in a wide variety tumor, including glioblastoma (Exp. Opin. Drug Deliv. 8:1041- 1056, 2011). Objective: The goal of this work was to compare the radiolabeling efficiency of the GRGDYV and GRGDHV peptides when radiolabeled with the 131 I and 99m Tc radioisotopes, respectively, as well as, to evaluate the features of synthesized complexes. Methods: The GRGDYV and GRGDHV fragments were manually synthesized by peptide synthesis in solid phase accordingly to the Fmoc protocol and purified by preparative HPLC. The GRGDYV and GRGDHV peptides were radiolabeled with the I-131 and Tc-99m radioisotopes respectively, through of the direct method of radiolabeling. The radioiodination was evaluated and optimized using the methodology of Chloramine-T and for the peptide containing the histidine aminoacid the tricarbonyl method was used. Radiochemical yield analyses of [ 131 I]-GRGDYV and [ 99m Tc]-GRGDHV peptides were performed by thin layer chromatography on silica gel TLC-SG (Al) in ACN 95%. The radiolabeled peptides were purified by using solid phase extraction (Sep-Pak C18 filter). The stability studies were realized at 2, 24, 48 and 72 hours in room temperature and refrigerate (4 deg C) for [ 131 I]-GRGDYV and up to 6 hours for the fragment [ 99m Tc]-GRGDHV. Partition coefficient was determinate for both radiopeptides. Results: The peptides [ 131 I]-GRGDYV and [ 99m Tc]-GRGDHV were efficiently synthesized, radiolabeled and showed radiochemical yield of 91.02% ± 1.68 (n=5

  14. Comparison of radiolabeling efficiency of peptides containing the RGD domain using the Tc-99M and I-131 radioisotopes

    Sobral, Danielle V.; Cabral, Francisco Romero; Malavolta, Luciana [Santa Casa de São Paulo, SP (Brazil). Faculdade de Ciências Médicas; Durante, Ana C. Ranucci; Miranda, Ana C. Camargo; Barbosa, Marycel R. F.Figols de [Instituto Israelita de Ensino e Pesquisa Albert Einstein, São Paulo, SP (Brazil)

    2017-07-01

    Full text: Introduction: Radiolabeled peptides have become very important in nuclear medicine and oncology in recent years mainly because they represent the molecular basis for in vivo imaging and radiopharmaceutical therapy with high specificity and affinity for over expressed receptors in tumors (Thno 2(5):481-501, 2012 / Drug Discov. Today. 7:1224-1232, 2012). In this context, peptides containing the RGD domain which possess high affinity for the αvβ3 integrin receptor have become an important tool in a wide variety tumor, including glioblastoma (Exp. Opin. Drug Deliv. 8:1041- 1056, 2011). Objective: The goal of this work was to compare the radiolabeling efficiency of the GRGDYV and GRGDHV peptides when radiolabeled with the {sup 131}I and {sup 99m}Tc radioisotopes, respectively, as well as, to evaluate the features of synthesized complexes. Methods: The GRGDYV and GRGDHV fragments were manually synthesized by peptide synthesis in solid phase accordingly to the Fmoc protocol and purified by preparative HPLC. The GRGDYV and GRGDHV peptides were radiolabeled with the I-131 and Tc-99m radioisotopes respectively, through of the direct method of radiolabeling. The radioiodination was evaluated and optimized using the methodology of Chloramine-T and for the peptide containing the histidine aminoacid the tricarbonyl method was used. Radiochemical yield analyses of [{sup 131}I]-GRGDYV and [{sup 99m}Tc]-GRGDHV peptides were performed by thin layer chromatography on silica gel TLC-SG (Al) in ACN 95%. The radiolabeled peptides were purified by using solid phase extraction (Sep-Pak C18 filter). The stability studies were realized at 2, 24, 48 and 72 hours in room temperature and refrigerate (4 deg C) for [{sup 131}I]-GRGDYV and up to 6 hours for the fragment [{sup 99m}Tc]-GRGDHV. Partition coefficient was determinate for both radiopeptides. Results: The peptides [{sup 131}I]-GRGDYV and [{sup 99m}Tc]-GRGDHV were efficiently synthesized, radiolabeled and showed

  15. Optimizing the number of equivalent iterations of 3D OSEM in SPECT reconstruction of I-131 focal activities

    Koral, Kenneth F.; Kritzmaan, James N.; Rogers, Virginia E.; Ackermann, Robert J.; A Fessler, Jeffrey

    2007-01-01

    To externally estimate the radiation dose to a tumor during therapy with I-131 radiopharmaceuticals, and its distribution, one must accurately estimate activity, and its distribution, by means of SPECT imaging. Our objective is to characterize the quantification of the total activity in focal targets and in their uniform background, and of the activity distribution within the targets, after 3D Ordered Subsets Expectation Maximization (OSEM) reconstruction with attenuation and scatter correction and no post smoothing, in the good-counting-statistics case. A cylindrical phantom containing seven spheres simulating tumors, ranging in volume from 209 to 4.2 cm 3 , and filled with an I-131 water solution containing background, was imaged. A Siemens Symbia SPECT/CT scanner was used to acquire 128x128 projection images, employing 60 angles over 360 o . With dynamic SPECT, 10 sequential acquisitions of 15 min duration each were obtained and each was reconstructed with particular values of the number of subsets and the number of iterations. Let the product of the number of subsets times the number of iterations equal the equivalent number of iterations, EI. The counts-to-activity conversion factor was derived from the average ratio of total count divided by true activity for the largest sphere at the largest value of EI. Then, for the activity of each sphere at each of the values of EI, we evaluated (1) the fractional variance (variance in estimate over true activity), (2) the fractional bias (average estimate bias over true activity) and (3) the fractional error (the root mean square error (RMSE) in the estimate divided by the true activity). The fractional bias and fractional variance were smaller for the larger spheres compared to the smaller (the fractional bias decreased faster with an increase in the fractional variance for them as well). The RMSE was dominated by the bias. The fractional error decreased as EI increased for all sphere sizes. The minimum average value

  16. Immunoscintigraphy of human pancreatic carcinoma in nude mice with I-131-F(ab')/sub 2/-fragments of monoclonal antibodies

    Senekowitsch, R.; Maul, F.D.; Wenisch, H.J.C.; Kriegel, H.; Hor, G.

    1985-01-01

    In the present study radioiodinated F(ab')/sub 2/-fragments of CA19-9 and antibody that reacts specifically with human gastrointestinal cancer were examined for their ability to detect human pancreatic carcinoma hosted in nude mice. Tumor-bearing mice received 80μCi of I-131-F(ab')/sub 2/ with a specific activity of 1.8μCi/μg. All mice were imaged after the injection and every 24hr up to 6 days. The retained radioactivity was also registered with a whole-body counter immediately after imaging. As a control F(ab's)/sub 2/ of a nonspecific antibody were administered in parallel to another group of animals bearing the same tumor. Three animals of each group were killed at 1,2,4 and 8 days for determination of the distribution of both labeled antibody-fragments. On scintigraphic images obtained with the CA19-9-F(ab')/sub 2/ the tumors could be visualized 24hr after injection, the best dilineation however was achieved 96hr p.i.. The biodistribution data exhibited a more rapid blood clearance for the specific fragments compared to that for the unspecific ones. Tumors showed an increase in uptake up to 48hr reaching 1.7% of the injected dose per gram, declining to values of 0.08%/g at day 6 p.i.. The highest tumor-to-blood ratios were found after 96h. They were 7 for the CA19-9-fragments compared to 1.5 for the unspecific fragments. The whole body counting revealed a more rapid excretion for the fragments of the specific monoclonal antibodies than for the unspecific ones. In summary the authors were able to show that CA19-9-F(ab')/sub 2/-fragments can be used for immunodetection of human pancreatic carcinoma hosted in nude mice

  17. Clinical Significance of Diffuse Intrathoracic Uptake on Post-Therapy I-131 Scans in Thyroid Cancer Patients

    Choi, Hyun Su; Kim, Sung Hoon; Park, Sonya Youngju; Park, Hye Lim; Seo, Ye Young; Choi, Woo Hee

    2014-01-01

    The purpose of this study was to identify the frequency and possible cause of diffuse intrathoracic uptake on post-therapy I-131 scans in thyroid cancer patients. We retrospectively reviewed 781 post-therapy scans of 755 thyroid cancer patients who underwent total thyroidectomy and radioactive iodine therapy between January and December 2010. Diffuse intrathoracic uptake on post-therapy scans was examined, and clinical patient characteristics including sex, age, regimen for thyroid-stimulating hormone (TSH) stimulation (thyroid hormone withdrawal or recombinant human TSH injection), TSH, thyroglobulin (Tg) and anti-thyroglobulin antibody (anti-Tg Ab) levels, therapeutic dose of radioactive iodine therapy and prior history of radioactive iodine therapy were recorded.Scan findings were correlated with chest CT, chest radiographs, laboratory tests and/or clinical status. Diffuse intrathoracic uptake without evidence of pathologic condition was categorized as indeterminate. The association between clinical characteristics and intrathoracic uptake were analyzed for negative intrathoracic uptake and indeterminate uptake groups. Diffuse intrathoracic uptake on post-therapy scans was demonstrated in 39 out of 755 (5.2 %) patients, among which 3 were confirmed as lung metastasis. The 14 patients that showed high Tg or anti-Tg Ab levels were considered to be at risk of having undetected micrometastasis on other imaging modalities. The remaining 22 were indeterminate (2.9 %). Upon comparison of negative intrathoracic uptake and indeterminate uptake groups, TSH stimulation by thyroid hormone withdrawal was shown to be significantly correlated with diffuse intrathoracic uptake (p <0.05). The frequency of diffuse intrathoracic uptake on post-therapy scans was 5.2 % and could be seen in thyroid cancer patients with underlying lung metastasis as well as those without definite pathologic condition. In the latter, there was a higher frequency for diffusely increased intrathoracic

  18. Thyroid remnant ablation using 1,110 MBq of I-131 after total thyroidectomy. Regulatory considerations on release of patients after unsealed radioiodine therapy

    Kusakabe, Kiyoko; Yokoyama, Kunihiko; Ito, Koichi

    2012-01-01

    This study was undertaken to measure the radiation exposure level of caregivers following outpatient NaI (I-131) 1,110 MBq therapy for remnant thyroid ablation after total thyroidectomy in patients with differentiated thyroid cancer, and to evaluate the influence of activities of daily living on radiation exposure level, with the goal of proposing an optimum method of I-131 therapy. The study included 37 patients with differentiated thyroid cancer, who had undergone total thyroidectomy and received outpatient based remnant thyroid ablation using NaI (I-131) 1,110 MBq, who were satisfying the following requirements: patients who have no evidence of distant metastases, whose living environments were appropriate for outpatient I-131 (1,110 MBq) therapy, and patients who gave written informed consent. The dose rate at a distance of 1 m from the body surface of the patient at the moment of release was measured using survey meters of the GM type or ionization chamber type. The dose level for the caregiver was measured with a personal dosimeter in all cases. The dose rate at a distance of 1 m from the patient's body surface 1 h after I-131 administration was in the range of 29-115 μSv/h (mean 63.8 μSv/h). The 7-day cumulative effective dose of caregivers was 0.11±0.08 mSv, on an average, in 34 dosimeters. In 31 of 34 dosimeters, cumulative effective dose of caregivers was below 0.2 mSv. Dose levels exceeding 0.2 mSv were recorded in 3 cases (0.21, 0.35 and 0.43 mSv in one case each). These results suggest that the exposure level of family members (caregiver and others) was minimal and is lower than the radiation levels affecting human environments. Outpatient-based remnant thyroid ablation with I-131 (1,110 MBq) performed after total thyroidectomy in patients with differentiated thyroid cancer is safe if applied in accordance with the appropriate supervision and guidance by experts with certain qualifications. (author)

  19. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  20. Clinical importance of technetium-99m-methoxyisobutylisonitrile (MIBI) scintigraphy in differentiated thyroid carcinoma patients with elevated thyroglobulin levels and negative I-131 scanning results

    Kuecuek, N.O.; Kulak, H.A.; Aras, G.

    2006-01-01

    The aim of this study was to evaluate the potential contribution of Tc-99m-MIBI scintigraphy to the follow-up of patients with differentiated thyroid carcinoma, who had elevated Tg levels and negative I-131 whole-body scan (WBS) results. In this retrospective study, we evaluated 28 patients with differentiated thyroid carcinoma, who had total or near total thyroidectomy followed by an ablative dose of I-131 at various time intervals (15 women, 13 men; mean age 43±17 years). All patients were treated with T4 suppression. After a mean follow-up period of 6.1 years (range 3-15) all patients were determined to have a high serum Tg concentrations (>2 ng/ml) and previous negative I-131 WBS results. All patients were examined for metastatic sites using Tc-99m-MIBI scan. Scans were visually evaluated for detecting lymph node metastases and/or local recurrence, lung metastases and skeletal metastases. Tc-99m-MIBI scan demonstrated lesions in 23 patients (83.3%). In five patients with negative Tc-99m-MIBI scan findings (FN results): Chest CT showed small-sized mediastinal LN metastases in 2 patients and lung metastases in another 2 patients (<1 cm); Neck CT showed small-sized cervical LN involvement in 1 patient. The sensitivity of detection for neck was 94.4%, for lung 63.6%, and for bone lesions 100%. For all scan sites taken together, the sensitivity of disease detection was 83.3%, the specificity was 50%, positive predictive value (PPV) was 96.2%, and finally negative predictive value (NPV) was 16.7%. We concluded that Tc-99m-MIBI scan should be considered as a supplementary scintigraphic method for the follow-up of patients with high serum Tg levels and negative I-131 WBS results, and it can help clinicians in making the decision to treat these patients. (author)

  1. Preliminary report of a fetal-thyroid overexposure case due to the administration of I-131 during the second trimester of pregnancy

    Gimenez, J.C.; Gutierrez, S.; Alcaraz, G.

    1992-01-01

    Sixty to eighty percent of patients with Graves's disease have antibodies directed against thyroglobulin or against thyroid microsomes. A contemporary interpretation is that thyroid stimulatory inmunoglobuline TSI mimics the action of TSH and stimulate the synthesis and release of thyroid hormone. In patient whose thyroids are capable of responding to such a trophic stimulus, TSI may be the mediator of hyperthyroxinemia. TSI cross the placenta and cause transient hyperthyroidism in some neonates (0,5-1 %) born to mothers who have high circulating levels of the antibodies. As regards adults aged 25 and up, administering I-131 radioactive iodine seems to be a satisfactory treatment for Graves' disease. Such a treatment, however, is to be avoided when treating either pregnant or breast-feeding women due to the effects that irradiation is likely to cause to the fetus or the suckling child. Even though such effects depend on the intrauterine developmental stage, the principal effects are as follows: (a) The embryo may be lethally affected; (b) Malformations and structure changes, or changes in the child's development are likely to occur; (3) The child may be mentally retarded; (4) An induction to cancer and leukemia is possible, and (e) Hereditary effect, may be expected. Moreover, it is a well-known fact that the fetal thyroid is able to capture and integrate iodine as of the 10th/12th gestation week. Thus, administering I-131 according to prescribed doses may define or suppress the thyroid function. Therefore, the highest precautions must be taken in order not to carelessly administer I-131 therapeutic doses to pregnant women. Any woman within the reproductive capacity range should be strongly advised that the pregnancy test is to be performed to avoid her fetus being irradiated. Precisely, the present paper deals with the inadvertent administering an I-131 therapeutic dose to pregnant woman with Graves disease whose child -unexpectedly enough- turned out to be

  2. Normalization of lymphocyte count after high ablative dose of I-131 in a patient with chronic lymphoid leukemia and secondary papillary carcinoma of the thyroid: case report

    Thom, Anneliese Rosmarie Gertrud Fischer; Hamerschlak, Nelson; Osawa, Akemi; Santos, Fabio Pires de Souza; Pasqualin, Denise da Cunha; Wagner, Jairo; Yamaga, Lilian Yuri Itaya; Cunha, Marcelo Livorsi da; Campos Neto, Guilherme de Carvalho; Funari, Marcelo Buarque de Gusmao; Teles, Veronica Goes

    2014-01-01

    The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and paraaortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells. (author)

  3. The outcome of I-131 ablation therapy for intermediate and high-risk differentiated thyroid cancer using a strict definition of successful ablation

    Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko

    2017-01-01

    This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in nigh-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels <2 ng/ml in a TSH-stimulated state after ablation. We extracted data on patients' age, sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P < 0.001), while no significant differences were found for other factors between the groups. Furthermore, thyroglobulin levels >10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria. (author)

  4. The outcome of I-131 ablation therapy for intermediate and high-risk differentiated thyroid cancer using a strict definition of successful ablation.

    Watanabe, Ken; Uchiyama, Mayuki; Fukuda, Kunihiko

    2017-09-01

    This article examines the outcome of radioactive iodine ablation therapy for thyroid cancer in high-risk patients and investigates background factors influencing ablation failure. We included 91 patients in this retrospective analysis and evaluated the ablation success rate. Successful ablation was defined as the absence of visible iodine-131 (I-131) accumulation in the thyroid bed after whole-body scans and thyroglobulin levels sex, I-131 dose, pathology, resection stump findings, tumor T category and thyroglobulin levels, which could affect ablation outcome. Successful ablation was achieved in only 14 patients (15.4%). Pre-ablation serum thyroglobulin levels were significantly higher in the ablation failure group than in the success group (P 10 ng/ml were significantly related to ablation failure after multivariate analysis (odds ratio 27.2; 95% confidence interval 2.469-299.7; P = 0.007). The ablation success rate was very low because of high thyroglobulin levels, even with high-dose I-131. High-risk patients, especially those with high thyroglobulin levels (>10 ng/ml), are unlikely to reach levels low enough to meet successful ablation criteria.

  5. The usefulness of I-131 MIBG scintigraphy in assessing the staging of neuroectodermal tumors in children - Our experience

    Budlewski, T.; Rogowski, F.; Luczynski, W.; Krawczuk-Rybak, M.

    2004-01-01

    Full text: Neuroendodermal tumors include pheochromocytoma, paraganglioma, medullary thyroid cancer and neuroblastoma. These malignant tumors derive from the primitive neural crest, which develops to sympathic nervous system. The tumors consist of cells that are capable of incorporating the amine precursors such as I-131 MIBG. The most common malignant tumor in childhood is neuroblastoma. The tested group included patients with neuroblastoma and one with pheochromocytoma treated in the Department of Oncology at the Paediatric University Hospital in Bialystok. There were 8 patients between the ages of 2 and 13. They have all undergone standard whole body scanning with a tomographic Nucline X-Ring camera made by Mediso, fitted with high-energy all purpose parallel hole collimator, a scan speed 5cm/ min and static images of 250,000 counts or 10 min per image. The study was performed 24-48 h after I-131 MIBG injection of 35 MBq activity. The results were obtained by antero-posterior and posterio-anterior projections (a whole body scan) and, if necessary, additional static images of chest and abdomen, skull, pelvis, and lower limbs. Clinical Characteristics of the Group: M.E. 12-year-old child with a right suprarenal tumor with morrow metastases. HP-neuroblastoma. The child was treated with a preoperative chemotherapy, operated and given postoperative chemotherapy (palliative therapy). The MIBG scintigraphy showed hypermetabolic focus in the pelvis and in the left vertex bone. Clinical test pointed to the progress of the disease. M.J. 6-year-old child with infiltrative retroperitoneal on both sides of celiac trunk with a metastases to mediastinum and bone marrow. HP-neuroblastoma. The first MIBG scintigraphy performed after Tsishidy operative procedure was negative. The second MIBG scintigraphy, one year later showed metastases to thigh bone, spine, and sacroiliac joint. Clinically proven progress of the disease. G.G. 2-year-old child with facial skeleton tumor and

  6. A prospective randomized study of the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in hyperthyroidism.

    Pusuwan, Pawana; Tuntawiroon, Malulee; Sritongkul, Nopamol; Chaudakshetrin, Pachee; Nopmaneejumruslers, Cherdchai; Komoltri, Chulalak; Thepamongkhol, Kullathorn; Khiewvan, Benjapa; Tuchinda, Pongpija; Sriussadaporn, Sutin

    2011-03-01

    To compare the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in patients with hyperthyroidism. One hundred fifty patients with proven hyperthyroidism were randomly allocated into the high (74 patients) and low (76 patients) dose regimen of I-131 treatment. Four patients of the high dose group and one patient of the low dose group were excluded because of lost follow-up. A gland-specific dosage was calculated on the estimated weight of thyroid gland and 24-hour I-131 uptake. The high and low I-131 dose regimens were 150 microCi/gm and 100 microCi/gm, respectively. The first mean radioiodine activity administered to the high and low dose group was 10.2 and 8 mCi, respectively. Repeated treatment was given to 25 patients of the high dose group and 40 patients of the low dose group. Clinical outcome and calculated costs for outpatient attendances, and laboratory tests together with initial and subsequent treatments were evaluated for one year after I-131 treatment. Elimination of hyperthyroidism that resulted in either euthyroidism or hypothyroidism was classified as therapeutic success. The cost effectiveness was also compared. At 6 months after treatment, 45 (64.3%) patients receiving high dose and 59 (78.7%) patients receiving low dose were hyperthyroidism. Clinical outcome at one year showed persistence of hyperthyroidism in 21 (30%) patients of the high dose regimen and 36 (48%) patients of the low dose regimen. At one year post treatment, it was demonstrated that the high dose regimen could eliminate hyperthyroidism in a significantly shorter time than the low dose regimen, i.e., 259.6 days and 305.5 days, respectively, p = 0.008). For the persistent hyperthyroid patients, the average total cost of treatment in the low dose group was significantly higher than that of the high dose group, i.e., 13,422.78 baht and 10,942.79 baht, respectively; p = 0.050). A high dose regimen of radioactive iodine treatment is more effective than

  7. The prevalence of thyroid tissue along the thyroglossal tract on SPECT/CT following I131 ablation therapy after total thyroidectomy for thyroid cancer

    Barber, T.W.; Cherk, M.H.; Yap, K.S.K.; Kalff, V.; Topliss, D.J.; Serpell, J.W.

    2015-01-01

    Full text of publication follows. Aim: the aims of this study are first to determine the prevalence of thyroid tissue along the thyroglossal tract on SPECT/CT and secondly to assess the contribution of this tissue to total neck I-131 activity in patients treated with I-131 ablation therapy after total thyroidectomy for thyroid cancer. Materials and methods: a total of 63 consecutive patients with well differentiated thyroid cancer treated with total thyroidectomy underwent whole body planar imaging and SPECT/CT of the neck 48 hours following ablative I-131 therapy. On SPECT/CT, thyroglossal tract thyroid tissue was defined as radioiodine activity in the anterior neck, superior to the thyroid bed in close proximity to the midline without evidence of localisation to lymph nodes. On planar imaging, thyroglossal tract thyroid tissue was defined as linear radioiodine activity in the midline of the neck superior to the thyroid bed. SPECT/CT and planar images were classified by two independent reviewers as positive, negative or equivocal with interobserver agreement quantified using a Kappa score. Disagreement was resolved using a third reviewer. Quantitation of thyroglossal tract thyroid tissue and total neck I-131 activity was performed using region of interest analysis on planar imaging following localisation on SPECT/CT. Results: thyroglossal tract thyroid tissue was present in 31/63 (49%; 95% CI: 37-61%) patients on SPECT/CT. In these 31 patients, thyroglossal tract thyroid tissue contributed to an average of 49% of total neck activity. Interobserver agreement was substantial on SPECT/CT (Kappa = 0.76; 95% CI: 0.61-0.91) and fair on planar imaging (Kappa = 0.31; 95% CI: 0.15-0.47). Conclusion: thyroid tissue along the thyroglossal tract was present in one half of patients in our study population and can contribute to a significant amount of total neck I-131 activity. Given the high prevalence of thyroglossal tract thyroid tissue, our results suggest that total neck

  8. MALKS®: especificações e desenvolvimento MALKS®: specifications and development

    Gustavo Victor

    2006-04-01

    Full Text Available OBJETIVO: Descrever as características de uma nova câmara anterior artificial e discutir suas vantagens (MALKS®, Loktal, São Paulo, Brasil. MÉTODOS: Análise e descrição das especificações técnicas utilizadas na câmara anterior artificial MALKS® (Micro automated lamellar keratoplasty system. RESULTADOS: O MALKS® é constituído de oito partes: a câmara artificial; b anel fixador da córnea; c porca de travamento do anel fixador; d trilho e ajustador do diâmetro do disco lamelar; e aplanadores para aferição e definição do diâmetro do disco lamelar; f sistema de infusão, que possibilita o controle digital objetivo peroperatório da pressão intracameral; g microcerátomo automático; h trépano marcador. CONCLUSÃO: O MALKS® utiliza o mesmo microcerátomo automático desenvolvido para LASIK, possibilita a obtenção de lamelas corneanas de espessura e diâmetro programados, assim como o controle objetivo peroperatório digital da pressão intracameral (PIC. Esta câmara anterior artificial pode ser ferramenta importante tanto para as cirurgias de transplante lamelar superficial quanto endotelial.PURPOSE: To describe the characteristics of a new artificial anterior chamber (MALKS®, Loktal, São Paulo, Brasil. METHODS: Characteristics analysis and description of a new artificial anterior chamber MALKS® (Micro automated lamellar keratoplasty system. RESULTS: MALKS®is composed of eight parts: a artificial chamber; b cornea's fix ring; c nut to join the cornea's fix ring; d rail and adjuster of lamellar diameter; e flatteners, to pre-determine lamellar diameter; f infusion system, that allows the digital objective peroperative control of the intracameral pressure; g automated microkeratome, and h marker. CONCLUSION: MALKS® uses the same automated microkeratome developed for LASIK, can allow corneal lamella obtention with predetermined thickness and diameter, as well as the digital objective peroperative control of the

  9. Doses to the hand during the administration of radiolabeled antibodies containing Y-90, Tc-99m, I-131, and Lu-177

    Barber, D.E. [Minnesota Univ., Minneapolis, MN (United States). School of Public Health; Carsten, A.L.; Kaurin, D.G.L.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1997-02-01

    Exposure of the hands of medical personnel administering radiolabeled antibodies (RABs) was evaluated on the basis of (a) observing and photo-documenting administration techniques, and (b) experimental data on doses to thermoluminescent dosimeters (TLDs) on fingers of phantom hands holding syringes, and on syringes, with radionuclides in the syringes in each case. Actual exposure data for I-131 and Lu-177 were obtained in field studies. Variations in handling and administration techniques were identified. Dose rates measured using TLDs on the surface of loaded syringes were adjusted for differences in electronic stopping power, absorption coefficients, and attenuation between dosimeters and tissue to estimate dose-to-skin averaged over 1 cm{sup 2} at 7 mg cm{sup {minus}2} depth for Y-90, Tc-99m, I-131, and Lu-177. Dose rate coefficients to the skin, if in contact with the syringe wall, were 89, 1.9, 3.8, and 0.41 {micro}Sv s{sup {minus}1} per 37 MBq (1 mCi) for Y-90, Tc-99m, I-131, and Lu-177, respectively. For dose reduction, when using Y-90 the importance was clearly indicated of (a) avoiding direct contact with syringes containing RABs, if practical, and (b) using a beta-particle shield on the syringe. In using a syringe for injection, doses can best be approximated for the geometry studied by (a) wearing a finger dosimeter on the middle finger, toward the outside of the hand, on the hand operating the plunger, and (b) wearing finger dosimeters on the inner (palm) side of the finger on the hand that supports the syringe for energetic beta-particle emitters, such as Y-90 and Re-188.

  10. Influence of radiolysis and gas-liquid partition of I-131 in accumulated water on late phase source terms at Fukushima NPP accident

    Hidaka, Akihide

    2014-01-01

    In the process of core cooling at Fukushima Daiichi nuclear power plants accident, large amount of contaminated water was accumulated in the basements of the reactor buildings at Units 1 to 4. The present study estimated the quantities of I-131 and Cs-137 in the water as of late March based on the press-opened data. The estimated ratios of I-131 and Cs-137 quantities to the core inventories are 0.51%, 0.85% at Unit 1, 74%, 38% at Unit 2 and 26%, 18% at Unit 3, respectively. According to the Henry's law, certain fraction of iodine in water could be released to atmosphere due to gas-liquid partition and contribute to increase in the release to environment. A lot of evaluations for I-131 release have been performed so far by severe accident codes such as MELCOR or the reverse estimation with atmospheric dispersion code such as SPEEDI using the monitoring data. The SPEEDI reverse predicted significant release until March 26 while no prediction in MELCOR after March 17. The present study showed that iodine release from accumulated water due to radiolytic conversion from I - to I 2 and gas-liquid partition of I 2 may explain the release between March 17 and 26. This strongly suggests a need for improvement of current MELCOR approach which treats the release only from containment breaks for several days after the core melt. The study also indicates that the release of radioactive iodine from accumulated water in the basements of reactor buildings could become a great concern for the consequence of Fukushima accident. (author)

  11. Multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain. Pt. 1

    Koehler, H.; Peterson, S.R.; Owen Hoffman, F.

    1991-03-01

    Comprehensive measurements of I-131 and Cs-137 in the environment after the Chernobyl accident provided a unique opportunity for the collection of environmental transfer data sets. These come from 13 locations in the northern hemisphere which experienced levels of contamination that spanned approximately three orders of magnitude. Data have been compiled for radionuclide concentrations in air, rain, pasture vegetation, milk, beef and grain. In addition background information has been collated for factors such as prevailing meteorological conditions, location description, and local agricultural practices. Participants were asked to predict radionuclide concentrations in forage, milk, beef and grain from radionuclide concentrations in air, the daily amounts of precipitation and other pertinent information. This was a blind test in that the locations to which the input data referred were not revealed to the participants until after they had submitted their predictions. Twenty-three models were involved in the study. This report compares observations and predictions for deposition, time- integrated concentrations in forage, milk, beef and grain, to help assess understanding of individual processes, time-dependent concentrations in forage, milk and beef. In general, predictions of time-integrated concentration of I-131 and Cs-137 in forage, milk (normalized for forage) and beef are within a factor of 10 of the observations. About 50% of the predictions of I-131 and Cs-137 in forage and just over 30% of the predictions of those nuclides in milk (normalized for forage) fall within a factor of 2 of the observations. Documentation of the measurements, models, methods of analysis and model results is presented in the appendices. (au) (75 refs.)

  12. Doses to the hand during the administration of radiolabeled antibodies containing Y-90, Tc-99m, I-131, and Lu-177

    Barber, D.E.

    1997-02-01

    Exposure of the hands of medical personnel administering radiolabeled antibodies (RABs) was evaluated on the basis of (a) observing and photo-documenting administration techniques, and (b) experimental data on doses to thermoluminescent dosimeters (TLDs) on fingers of phantom hands holding syringes, and on syringes, with radionuclides in the syringes in each case. Actual exposure data for I-131 and Lu-177 were obtained in field studies. Variations in handling and administration techniques were identified. Dose rates measured using TLDs on the surface of loaded syringes were adjusted for differences in electronic stopping power, absorption coefficients, and attenuation between dosimeters and tissue to estimate dose-to-skin averaged over 1 cm 2 at 7 mg cm -2 depth for Y-90, Tc-99m, I-131, and Lu-177. Dose rate coefficients to the skin, if in contact with the syringe wall, were 89, 1.9, 3.8, and 0.41 microSv s -1 per 37 MBq (1 mCi) for Y-90, Tc-99m, I-131, and Lu-177, respectively. For dose reduction, when using Y-90 the importance was clearly indicated of (a) avoiding direct contact with syringes containing RABs, if practical, and (b) using a beta-particle shield on the syringe. In using a syringe for injection, doses can best be approximated for the geometry studied by (a) wearing a finger dosimeter on the middle finger, toward the outside of the hand, on the hand operating the plunger, and (b) wearing finger dosimeters on the inner (palm) side of the finger on the hand that supports the syringe for energetic beta-particle emitters, such as Y-90 and Re-188

  13. Dosimetric contribution of the organs of the I123, I124 and I131 bio-kinetics in the dose estimate for euthyroid adults

    Vasquez, A. M.; Rojas, A. R.; Castillo, D. C.; Idrogo, C. J.; Flores, U. H.

    2011-10-01

    Using the formalism MIRD and the representation of Crysty-Eckerman for the thyroid adult, is demonstrated that the dosimetric contributions of source organs of the biokinetics of the radiopharmaceuticals I 123 , I 124 and I 131 (iodine) are not significant in the dose estimate. Therefore, the total absorbed dose by the gland is its auto-dose. Equally, the reported results do not present significant differences to the results found by the Marinelli scheme (auto-dose) for the thyroid represented by a sphere of 20 grams. (Author)

  14. The initial investigation of radiation dose rate at X-ray department and patients treating thyroid by I-131 at nuclear medicine department

    Nguyen Van Kinh; Vo Thanh Cuong

    2000-01-01

    Survey meter NSM 150 Fuji with detector Geiger Muller has been used to assess for average annual exposure dose which affect radiographer ≤ 2 mSv per year, the staff involved with Fluoroscopy ≤ 19 mSv per year. Dose rate in waiting area of patient is a range from 0.2 to 0.8 μSv/h. Patients who have been treated by radioiodine, may be only discharged when the remaining activity is 400.2 ±368.8 MBq. Radioactivity of I-131 and Tc-99m in the sewage system of hospital is 0.4x10 -11 Ci/l. (author)

  15. Clinical experience of 2-hour I-131 thyroid uptake significance in considering the radioiodine Graves' disease treatment dose: A retrospective study

    Al-Shammeri, I.; Al-Deen Mahmood, S.; Al-Mohannadi, S.; Ballani, N.

    2015-01-01

    Purpose: It has been noticed that Graves' disease patients with high turnover are likely to experience under dosage when calculating the radioiodine therapeutic dose. We aim to demonstrate our clinical experience of 2-h I-131 uptake% value in estimating the radioiodine dose for Graves' disease patients with rapid washout. Material and methods: We reviewed the medical records for 2080 Graves' disease patients who received radioiodine treatment(s). Patients were distinguished by 2-h I-131 thyroid uptake%: 249 patients (group I) exhibited a rapid washout (>25%), and 250 patients (group II control group) demonstrated normal uptake (6–15%); the age and sex were balanced for both groups. These cases were reviewed for the time taken to control the condition clinically (ideally 3 months is the time needed), the time taken to achieve hypothyroidism (average time is 6 months), and the number of repeated treatments for recurrent thyrotoxicosis or failure of treatment. Results: In 152/249 (61%) patients, the condition was not controlled in the 3 month period post treatment and subsequently they needed more frequent and closer follow up, as opposed to 47/250 patients (19%) in the control group-II. At 6 months, 119/249 (48%) patients in group-I had not achieved hypothyroidism, as opposed to 28/250 patients (11%) in group-II. Seventy-seven patients in group-I (31%) needed a second or third therapeutic dose, as opposed to 10/250 patients (4%) in group-II. Conclusion: We believe that a higher radioiodine dose with significant rapid washout in the thyroid gland of Graves' disease patients would give a greater treatment success rate. - Highlights: • We present our clinical experience of 2-h I-131 uptake% value in Graves' disease. • We reviewed records of hyperthyroid patients who received radioiodine treatment. • Two patients' groups were distinguished by normal and high 2-h I-131 uptake%. • The two groups showed different radioiodine treatment

  16. Long-Term Quality of Life and Pregnancy Outcomes of Differentiated Thyroid Cancer Survivors Treated by Total Thyroidectomy and I131 during Adolescence and Young Adulthood

    Melanie Metallo

    2016-01-01

    Full Text Available Introduction. Differentiated thyroid cancer (DTC is rare and confers good prognosis. Long-term health related quality of life (HRQoL and pregnancy outcomes are not well known in subjects treated during adolescence and young adulthood. Methods. Cross-sectional analysis of HRQoL and global self-esteem, using SF-36 and ISP-25 surveys, and of pregnancy outcomes in female survivors of DTC treated by total thyroidectomy and I131 before age of 25 years. Results. Forty-five of 61 patients (74% responded to the survey. Cumulative I131 activity was ≤3.85 GBq in 18 subjects and >3.85 GBq in 27 subjects. Mean time from diagnosis was 7.6 ± 5.2 years for the group ≤ 3.85 GBq versus 16.9 ± 11.6 years for the group > 3.85 GBq (P 3.85 GBq and 10 in patients from the group ≤ 3.85 GBq. Frequency of miscarriages was of 17% (group > 3.85 GBq and 10% (group ≤ 3.85 GBq with 9 and 24 live births, respectively. No congenital malformations or first year mortality was noted. Conclusion. Long-term HRQoL, global self-esteem, and pregnancy outcomes are not affected in young female survivors of DTC.

  17. The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia

    Wurdiyanto, G; Candra, H

    2016-01-01

    The standardization of radioactive sources ( 125 I, 131 I, 99m Tc and 18 F) to calibrate the nuclear medicine equipment had been carried out in PTKMR-BATAN. This is necessary because the radioactive sources used in the field of nuclear medicine has a very short half-life in other that to obtain a quality measurement results require special treatment. Besides that, the use of nuclear medicine techniques in Indonesia develop rapidly. All the radioactive sources were prepared by gravimetric methods. Standardization of 125 I has been carried out by photon- photon coincidence methods, while the others have been carried out by gamma spectrometry methods. The standar sources are used to calibrate a Capintec CRC-7BT radionuclide calibrator. The results shows that calibration factor for Capintec CRC-7BT dose calibrator is 1,03; 1,02; 1,06; and 1,04 for 125 I, 131 I, 99m Tc and 18 F respectively, by about 5 to 6% of the expanded uncertainties. (paper)

  18. The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia

    Wurdiyanto, G.; Candra, H.

    2016-03-01

    The standardization of radioactive sources (125I, 131I, 99mTc and 18F) to calibrate the nuclear medicine equipment had been carried out in PTKMR-BATAN. This is necessary because the radioactive sources used in the field of nuclear medicine has a very short half-life in other that to obtain a quality measurement results require special treatment. Besides that, the use of nuclear medicine techniques in Indonesia develop rapidly. All the radioactive sources were prepared by gravimetric methods. Standardization of 125I has been carried out by photon- photon coincidence methods, while the others have been carried out by gamma spectrometry methods. The standar sources are used to calibrate a Capintec CRC-7BT radionuclide calibrator. The results shows that calibration factor for Capintec CRC-7BT dose calibrator is 1,03; 1,02; 1,06; and 1,04 for 125I, 131I, 99mTc and 18F respectively, by about 5 to 6% of the expanded uncertainties.

  19. Evaluation of the absorbed dose during studies of the renal function due to I123 / I131 (hippuran) and In111 (DTPA)

    Vasquez, M.; Castillo, C.; Sarachaga, R.; Rojas, R.; Zelada, L.; Melendez, J.; Gomez, M.; Diaz, E.

    2014-08-01

    Using the methodology MIRD and representation Cristy-Eckerman for kidneys, bladder, and whole body as organs of the bio-kinetics of I 123 / I 131 (hippuran) and the In 111 (D PTA), the absorbed dose for studies of the renal function of adults due to the I 123 is 0,0071 mGy/MBq where 88.16% corresponds to its auto-dose and 11,96% to the organs of their bio-kinetics; while for the I 131 their dose is 0,032 mGy/MBq where 95,03% corresponds to its auto-dose and 4,97% to the organs of their bio-kinetics. For the In 111 their dose is 0,0168 mGy/MBq where 71,68% corresponds to their auto-dose and 28,32% to the organs of their bio-kinetics. In all the cases the dosimetric contributions of the organs of the bio-kinetics (whole body and urinary bladder) are very significant, and this fundamentally is due to the photons of the whole body. (Author)

  20. Estimation of ingestion dose due to I-131 in the initial month by using food-monitoring data after the Fukushima nuclear disaster in Japan

    Yamaguchi, Ichiro [National Institute of Public Health, Department of Environmental Health, Wako, Saitama (Japan)

    2012-11-15

    The committed equivalent dose to the thyroid caused by I-131 and the effective dose caused by I-131, Cs-134 and Cs-137 due to ingestion immediately after the accidental releases following the Fukushima nuclear disaster in March 2011 were estimated retrospectively by using measured food data. A food monitoring dataset provided by the Ministry of Health, Labour and Welfare (MHLW) up to April 18, 2011 (N=1,752) was used for this study. Information on food consumption by 99 food categories was made available by using the original data of the Japanese National Food Consumption Survey, which was conducted in 2009 (N=9,942). Food concentration every 4 days and food consumption in each food category was randomly picked up (N=100,000). The levels of radioactive iodine and cesium were summed for one month and then converted to equivalent doses to the thyroid and effective doses. These doses in the first month after the Fukushima nuclear power plant accident were evaluated by using the food monitoring dataset provided by the MHLW. Assuming that food was randomly extracted from monitored food samples and food restrictions were fully implemented, the 90%tile of the equivalent doses to the thyroid and the effective doses in 1- to 6-year-old children were estimated to be around 1 mSv and 0.07 mSv, respectively. Several different methods should be considered to reduce limitations of this estimation. (author)

  1. Normalization of lymphocyte count after high ablative dose of I-131 in a patient with chronic lymphoid leukemia and secondary papillary carcinoma of the thyroid: case report; Normalizacao da contagem de linfocitos apos dose ablativa de I-131 em um paciente com leucemia linfoide cronica e carcinoma papilifero da tireoide: relato de caso

    Thom, Anneliese Rosmarie Gertrud Fischer; Hamerschlak, Nelson; Osawa, Akemi; Santos, Fabio Pires de Souza; Pasqualin, Denise da Cunha; Wagner, Jairo; Yamaga, Lilian Yuri Itaya; Cunha, Marcelo Livorsi da; Campos Neto, Guilherme de Carvalho; Funari, Marcelo Buarque de Gusmao, E-mail: afthom@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Teles, Veronica Goes [Sociedade Brasileira de Diabetes, Sao Paulo, SP (Brazil)

    2014-07-01

    The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and paraaortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells. (author)

  2. Our experience of high dose I-131 therapy in 75 patients with well differentiated carcinoma thyroid followed up over 5 years

    Dougall, P.; Kumar, A.; Ashok, P.; Chinwan, B.P.; Khan, B.; Pandey, D.; Joshi, N.D.

    2005-01-01

    Thyroid cancer is the most common endocrine malignancy. The epidemiology of thyroid cancer is variable, depending on the geographic location of the patient population. Well differentiated thyroid cancer (WTC), is responsive to high dose I-131 treatment, and is the most accepted form of therapy, even though the dose administered for ablation of residual thyroid tissue maybe controversial. At our centre, 75 patients of WTC, mean age 42.4 years, 22 males and 53 females (M:F 1:2.4), were treated with high dose oral I-131 therapy with a Total Mean Dose (TMD) of 263.6 mCi, 4 - 6 weeks post thyroidectomy. They were followed up over a period of 6 years. Twenty ( 26.7%) patients had follicular cancer (FC), 47 (62.7%) papillary cancer (PC) and 8 (10.7%) were mixed (MC), on histopathology, at presentation. 38 (50.7%) patients had only residual thyroid tissue (RTT) on I-131 whole body bone scan (WBS) and 37 (49.3%) presented with metastatic disease (MD) at the time of therapy. Of the 37 patients with MD, 21 (56.8%) had metastases to the lymph nodes, 6 (16.2%) to the lungs, 4 (10.8%) to bone, 3 (8.1%) to bone and lung, and 4 (10.8%) to lung plus lymph nodes. Twenty-three patients (7 FC , 13 - PC and 3 MC; 6 RTT, 17 - MD) , received more than one dose of I-131 with a TMD of 422.7 mCi (Range 88 1590 mCi ). 52 patients (13 FC, 34 PC, 5 MC; 20 MD and 32 RTT) received a single TMD of 104.4 (Range 39.5 219 mCi). On follow-up, 3 patients of FC with MD (2 lung metastasis and 1 with extensive lymph node metastasis), died within 3 months 2 years of therapy. 3 patients of MD (2 FC, 1-MC; 2 bone metastasis and 1 bone with lung metastasis) died after 5 .5 years, Of the 6 patients who died, 5 were FC and only 1 was MC. 2 patients with MD to lungs and bone had received a single dose and were lost to follow up. All patients with PC and FC with only RTT, were surviving at the end of 5 years. None of the patients with MD to lymph nodes died at the end of 5 years, either receiving single or

  3. Evaluation of radiation exposure of workers caring for the patient after administration of radionuclide I-131 based on the Monte Carlo

    Hudzietzova, J.; Sabol, J.; Fueloep, M.

    2013-01-01

    In the paper using the Monte Carlo method ( code MCNPX) were calculated absorbed doses in organs caregivers, from which thereafter was set the value of the equivalent dose in these organs by appropriate formulas and then effective doses in selected geometries using protective shielding devices. The results show that using of shielding aprons equivalent of 1 mm of lead will reduce the exposure of workers caring for patients after administration of the radionuclide I-131 by about 30%. If the caregiver without protective shielding aprons is located between two patients, the gamma rays will be reduced by about 18% due to averted body of caregiver, while the worker's personal dosimeter located at the chest will register approximately 40% lower value of personal dose equivalent. (authors)

  4. Long-Term Results of Fixed High-Dose I-131 Treatment for Toxic Nodular Goiter: Higher Euthyroidism Rates in Geriatric Patients

    Gül Ege Aktaş

    2015-10-01

    Full Text Available Objective: Geriatric patient population has special importance due to particular challenges. In addition to the increase in incidence of toxic nodular goiter (TNG with age, it has a high incidence in the regions of low-medium iodine intake such as in our country. The aim of this study was to evaluate the overall outcome of high fixed dose radioiodine (RAI therapy, and investigate the particular differences in the geriatric patient population. Methods: One hundred and three TNG patients treated with high dose I-131 (370-740 MBq were retrospectively reviewed. The baseline characteristics; age, gender, scintigraphic patterns and thyroid function tests before and after treatment, as well as follow-up, duration of antithyroid drug (ATD medication and achievement of euthyroid or hypothyroid state were evaluated. The patient population was divided into two groups as those=>65 years and those who were younger, in order to assess the effect of age. Results: Treatment success was 90% with single dose RAI therapy. Hyperthyroidism was treated in 7±7, 2 months after RAI administration. At the end of the first year, overall hypothyroidism rate was 30% and euthyroid state was achieved in 70% of patients. Age was found to be the only statistically significant variable effecting outcome. A higher ratio of euthyroidism was achieved in the geriatric patient population. Conclusion: High fixed dose I-131 treatment should be preferred in geriatric TNG patients in order to treat persistent hyperthyroidism rapidly. The result of this study suggests that high fixed dose RAI therapy is a successful modality in treating TNG, and high rates of euthyroidism can be achieved in geriatric patients.

  5. Multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain. Pt. 2

    1991-03-01

    BIOMOVS is an international study for testing and validating model predictions of the transfer of radionuclides and rare stable elements through the biosphere. The BIOMOVS A4 scenario was designed to test model prediction of the transfer of I-131 and Cs-137 from the atmosphere via pasture vegetation to milk and of the Cs-137 transfer from air to beef (via vegetation) and grain. This document is an appendix to the A4 report. It includes tables and figures of time-integrated results, a summary of a statistical analysis of time-dependent and representative figures of time-dependent results. The quantities to be predicted in this scenario were wet, dry and total deposition (Bq m -2 ) of I-131 and Cs-137, contamination of vegetation (Bq kg -1 d.w.), milk (Bq L -1 ), beef and grain (Bq kg -1 ). While with steady state models only time-integrated results for vegetation, milk and beef could be calculated, these quantities also were requested as time-series from users of dynamic models. A detailed description of the participating models is given in Appendix 3, while all collected observations are documented in Appendix 2 of the A4 report. A diskette with all observed data can be obtained from the Swedish National Institute of Radiation Protection, SSI, or from Harry Koehler, IAEA, Vienna, Austria. For time-integrated P/Os, graphs for all locations and all models and sometimes subsets of these are provided. For time-series, graphs are enclosed for the observations and some model results. These values are calculated across locations and across models for time-integrated predictions and for the P/O of entire time-series and subsets of these for the time-dependent predictions. (au)

  6. Introdução à nova linguagem ISO de especificação geométrica de produtos - Parte II: Modelo para a especificação e verificação geométricas

    José António Almacinha

    2006-01-01

    Neste artigo, o segundo de uma série de dois sobre os fundamentos da nova linguagem ISO de Especificação geométrica de produtos (GPS), baseada numa matematização dos conceitos e utilizável em concepção, fabricação e verificação, a atenção é dirigida ao modelo para uma abordagem integrada dos procedimentos de especificação e verificação geométrica de produtos, proposto pela ISO. Partindo da definição actual de especificação geométrica, introduzem-se os conceitos de "modelo da superfície não id...

  7. I-131 Treatment of Graves' Disease in an Unsuspected First Trimester Pregnancy; the Potential for Adverse Effects on the Fetus and a Review of the Current Guidelines for Pregnancy Screening

    Phuong Tran

    2010-01-01

    Full Text Available Graves' disease is a thyroid-specific autoimmune disorder in which the body makes antibodies to the thyroid-stimulating hormone receptor leading to hyperthyroidism. Therapeutic options for the treatment of Graves' disease include medication, radioactive iodine ablation, and surgery. Radioactive iodine is absolutely contraindicated in pregnancy as exposure to I-131 to the fetal thyroid can result in fetal hypothyroidism and cretinism. Here we describe a case of a female patient with recurrent Graves' disease, who inadvertently received I-131 therapy when she was estimated to be eight days pregnant. This was despite the obtaining of a negative history of pregnancy and a negative urine pregnancy test less than 24 hours prior to ablation. At birth, the infant was found to have neonatal Graves' disease. The neonatal Graves' disease resolved spontaneously. It was suspected that the fetal thyroid did not trap any I-131 as it does not concentrate iodine until 10 weeks of gestation.

  8. I-131 Treatment of Graves' Disease in an Unsuspected First Trimester Pregnancy; the Potential for Adverse Effects on the Fetus and a Review of the Current Guidelines for Pregnancy Screening

    Barrett Mark

    2010-03-01

    Full Text Available Graves' disease is a thyroid-specific autoimmune disorder in which the body makes antibodies to the thyroid-stimulating hormone receptor leading to hyperthyroidism. Therapeutic options for the treatment of Graves' disease include medication, radioactive iodine ablation, and surgery. Radioactive iodine is absolutely contraindicated in pregnancy as exposure to I-131 to the fetal thyroid can result in fetal hypothyroidism and cretinism. Here we describe a case of a female patient with recurrent Graves' disease, who inadvertently received I-131 therapy when she was estimated to be eight days pregnant. This was despite the obtaining of a negative history of pregnancy and a negative urine pregnancy test less than 24 hours prior to ablation. At birth, the infant was found to have neonatal Graves' disease. The neonatal Graves' disease resolved spontaneously. It was suspected that the fetal thyroid did not trap any I-131 as it does not concentrate iodine until 10 weeks of gestation.

  9. An oncolytic adenovirus regulated by a radiation-inducible promoter selectively mediates hSulf-1 gene expression and mutually reinforces antitumor activity of I131-metuximab in hepatocellular carcinoma.

    Zhang, Yan; Fang, Lin; Zhang, Quan'an; Zheng, Qin; Tong, Jinlong; Fu, Xiaohui; Jiang, Xiaoqing; Su, Changqing; Zheng, Junnian

    2013-06-01

    Gene therapy and antibody approaches are crucial auxiliary strategies for hepatocellular carcinoma (HCC) treatment. Previously, we established a survivin promoter-regulated oncolytic adenovirus that has inhibitory effect on HCC growth. The human sulfatase-1 (hSulf-1) gene can suppress the growth factor signaling pathways, then inhibit the proliferation of cancer cells and enhance cellular sensitivity to radiotherapy and chemotherapy. I(131)-metuximab (I(131)-mab) is a monoclonal anti-HCC antibody that conjugated to I(131) and specifically recognizes the HAb18G/CD147 antigen on HCC cells. To integrate the oncolytic adenovirus-based gene therapy and the I(131)-mab-based radioimmunotherapy, this study combined the CArG element of early growth response-l (Egr-l) gene with the survivin promoter to construct a radiation-inducible enhanced promoter, which was used to recombine a radiation-inducible oncolytic adenovirus as hSulf-1 gene vector. When I(131)-mab was incorporated into the treatment regimen, not only could the antibody produce radioimmunotherapeutic effect, but the I(131) radiation was able to further boost adenoviral proliferation. We demonstrated that the CArG-enhanced survivin promoter markedly improved the proliferative activity of the oncolytic adenovirus in HCC cells, thereby augmenting hSulf-1 expression and inducing cancer cell apoptosis. This novel strategy that involved multiple, synergistic mechanisms, including oncolytic therapy, gene therapy and radioimmunotherapy, was demonstrated to exert an excellent anti-cancer outcome, which will be a promising approach in HCC treatment. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  10. Os novos nomes do racismo: especificação ou inflação conceptual?

    Fernando Luís Machado

    2000-09-01

    Full Text Available Boa parte da vasta produção teórica que a sociologia e outras ciências sociais têm dedicado, nas últimas décadas, à problemática do racismo, especialmente no mundo anglo-saxónico, ao procurar dar conta das mutações de forma e conteúdo que ele sofreu desde as suas primeiras formulações e manifestações práticas, acaba por inflacioná-lo conceptualmente. Neste artigo, em que se analisa esse processo de inflação conceptual, muitas vezes associado a uma extrema ideologização e politização do conceito, tenta fazer-se, ao mesmo tempo, a especificação teórica do racismo, em cada uma daquelas que, consensualmente, se reconhece serem as suas três dimensões constitutivas: ideologia, preconceito e discriminação.

  11. [F-18-fluordeoxyglucose positron emission tomography on patients with differentiated thyroid cancer who present elevated human serum thyroglobulin levels and negative I-131 whole body scan].

    Ruiz Franco-Baux, J V; Borrego Dorado, I; Gómez Camarero, P; Rodríguez Rodríguez, J R; Vázquez Albertino, R J; Navarro González, E; Astorga Jiménez, R

    2005-01-01

    This study aimed to evaluate the role of Fluorine-18-fluorodeoxyglucose positron emission tomography (PET-FDG) in patients with elevated serum thyroglobulin (hTg) levels where thyroid cancer tissue does not concentrate radioiodine, rendering false-negative results on I-131 scanning. Whole-body PET imaging using FDG was performed in 54 patients (37 female, 17 male) aged 17-88 years: 45 with papillary tumors and 9 with follicular tumors who were suspected of having recurrent thyroid carcinoma due to elevated thyroglobulin levels (hTg > 2 ng/ml) under thyroid-stimulating hormone (TSH > or = 30 microIU/ml) in whom the iodine scan was negative. All whole body scans were obtained with diagnostic doses (185 MBq). Whole body PET imaging was performed in fasting patients following i.v. administration of 370 MBq FDG while the patients were receiving full thyroid hormone replacement. Before PET, 99mTc methoxyisobutylisonitrile scintigraphy (99mTc-MIBI) was done in 14 patients and morphologic imaging in 26 by CT scan. Positive PET results confirmed the presence of hypermetabolic foci in 25/54 patients (46.29 %). Positive findings were found for PET-FDG in patients with hTg levels higher than 10 ng/ml receiving full thyroid hormone replacement. 99mTc-MIBI demonstrated lesions in 7/14 patients (50 %). PET-FDG and 99mTc-MIBI had congruent positive results in 4/7 patients. All the lesions found by CT were detected by PET-FDG, while recurrent disease was found in 12/21 patients with previous negative CT. These results suggest that PET-FDG seems to be a promising tool in the follow-up of thyroid cancer and should be considered in patients suffering from differentiated thyroid cancer with suspected recurrence and/or metastases by elevated thyroglobulin levels, and negative I-131 whole body scans. PET-FDG might be more useful at hTg levels > 10 ng/ml.

  12. A practical guideline for the release of patients treated by I-131 based on Monte Carlo dose calculations for family members

    Han, Eun Young; Lee, Choonsik; Mcguire, Lynn; Bolch, Wesley E

    2014-01-01

    We recently published effective doses per time-integrated activity (mSv MBq −1  s −1 ) for paediatric and adult family members exposed to an adult patient released from hospital following I-131 therapy. In the present study, we intend to provide medical physicists with a methodology to estimate family member effective dose in daily clinical practice because the duration of post-radiation precautions for the patient–family member exposure scenario has not been explicitly delineated based on the effective dose. Four different exposure scenarios are considered in this study including (1) a patient and a family member standing face to face, (2) a patient and a family member lying side by side, (3) an adult female patient holding a newborn child to her chest and (4) a one-year-old child standing on the lap of an adult female patient following her I-131 therapy. The results of this study suggest that an adult female hyperthyroidism (HT) patient who was administered with 740 MBq should keep a distance of 100 cm from a 15-year-old child for six days and the same distance from other adults for seven days. The HT female patient should avoid holding a newborn against her chest for at least 16 days following hospital discharge, and a female patient treated with 5550 MBq for differentiated thyroid cancer should not hold her newborn child for at least 15 days following hospital discharge. This study also gives dose coefficients allowing one to predict age-specific effective doses to family members given the measured dose rate (mSv h −1 ) of the patient. In conclusion, effective dose-based patient release criteria with a modified NRC two-component model provide a site medical physicist with less restrictive and age-specific radiation precaution guidance as they fully consider a patient’s iodine biokinetics and photon attenuation within both the patient and the exposed family members. (note)

  13. I-124 PET/CT to Predict the Outcome of Blind I-131 Treatment in Patients with Biochemical Recurrence of Differentiated Thyroid Cancer : Results of a Multicenter Diagnostic Cohort Study (THYROPET)

    Kist, Jakob W.; de Keizer, Bart; van der Vlies, Manfred; Brouwers, Adrienne H.; Huysmans, Dyde A.; van der Zant, Friso M.; Hermsen, Rick; Stokkel, Marcel P. M.; Hoekstra, Otto S.; Vogel, Wouter V.

    Patients with suspected recurrence from differentiated thyroid carcinoma, based on an increased thyroglobulin (Tg) level and negative neck ultrasound (US), pose a clinical dilemma. Because standard imaging has a low yield identifying potential recurrence, blind I-131 treatment is often applied.

  14. Prospective randomized trial for the evaluation of the efficacy of low vs. high dose I-131 for post operative remnant ablation in differentiated thyroid cancer

    Barrenechea, E.A.; Laureta, E.G.; Gaston, J.C.; Al-Nahhas, A.; Padhy, A.K.

    2005-01-01

    The study was done under the auspices of the IAEA to evaluate the efficacy of low dose (50-60mCi) vs. High dose (100 mCi) for the post-operative remnant ablation of differentiated thyroid cancer and to determine other factors associated with successful ablation. There were eighty-six patients included in the study with a diagnosis of papillary, follicular or mixed type of thyroid cancer. They all have undergone near total thyroidectomy or total thyroidectomy and without any evidence of metastatic disease. Four to six weeks after the surgery and without thyroid hormone maintenance as well as iodine free diet and drugs, they underwent a total body scan and uptake using 1-3 mci of I-131. Serum TSH and thyroglobulin were also taken. Randomization was made thru the IAEA and the patients either got a low dose or a high dose depending on such randomization. Of the 86 patients included, there were a total of 76 evaluable cases. There were three dropouts because of other medical conditions as upper GI bleeding, lung cancer and leg fracture. The 7 other patients have not completed their follow-up body scan. Among these patients were 67 females and 19 males whose age range was 19 to 84 years old. There were 65 cases with histologic type of papillary cancer, 15 follicular and 6 mixed varieties. Forty-one patients were randomized to the high dose group while 35 patients were assigned to the low dose therapy group. These patients were confined till their radiation activity was below 2mR/hr. Monitoring of the patients were done during their hospital stay. Post-therapy body scan was done but not with all patients. Most of the side effects noted were sialitis, mild neck pains, nausea and occasional vomiting as well as ageusia. These patients were maintained on thyroid hormone depending on their sensitivity but almost all were given 200-300mgs per day. The older patients tolerated only around 150mcgs/day. After four to six months, serum TSH, thyroglobulin and total body scan were

  15. Status of thyroidal radioiodine (I-131) uptake and urinary iodine in Bangladesh population: A re-look following implementation of universal iodination of salt

    Alam, F.; Sultana Haque, F.; Karim, M.A.; Faruque, O.; Ali, L.; Azad Khan, A.K.

    2007-01-01

    Iodide plays a central role in thyroid physiology and in the production of thyroid hormones, which are essential for normal vertebrate growth and development. Radioiodine uptake test is one of the oldest radionuclide investigations for evaluation of thyroid function. On the other hand useful information about the nutritional status of a population can be obtained by measuring the prevalence of deficiency in a population. The main aim of this study was to find out the present status of urinary iodine and thyroid uptake status of people living in and around Dhaka City (Bangladesh). The present study was carried out over a period of three years from 1999 to 2002 involving 300 subjects inclusive of 216 females and 84 males. Efforts were made to randomly include people from a broad spectrum of social and economic strata, starting from people belonging to the lowest to the highest income groups; as well as people representing the urban, rural and suburban populations. Urinary iodine levels and 24 hour percentage radioiodine uptake by the thyroid were estimated in all subjects included in this study. Subsequently patients were grouped into four categories based on the values of their percentage 24-hour radioiodine uptake; e.g., Group-A (N-99) with lowest uptake (0-5%), Group-B (N=100) with uptake ranging between 5-10%, Group-C (N=73) with uptake ranging between 10-30% and Group D (N=28) with uptake above 30%. The median 24 hours RAIU values in groups A, B, C and D were 3, 7, 23 and 34% respectively. The corresponding mean urinary iodine levels in the four groups were 43.31, 33.95, 12.97 and 9.35μgm/dl respectively. The results have shown that 1.04, 3.48, 16.72 and 78.74% people studied had levels of urinary iodine indicating severe, moderate, mild or no iodine deficiency respectively as per the WHO Criteria (Severe: <2 μgm /dl, Moderate: 2-4.9 μgm /dl, mild: 5.0-9.9μgm /dl, normal: ≥ 10 μgm /dl). It may be noted that the normal values of Thyroidal I-131 uptake were

  16. A new and simple test for the exocrinic function of the pancreas: Analysis of the urine after oral application of a I-131 labeled triglyceride

    Kropp, J.; Schmidt, S.; Wunderlich, G.; Schendtke, K.U.; Breidert, M.; McPherson, D.; Knapp, F.F. Jr.

    2002-01-01

    Aim: A simple non-invasive test for the exocrine function of the pancreas would be attractive to diagnose various diseases of this organ. 1,2-dipalmitoyl-3-[(15-p-[I-131]-iodophenyl)pentadecan-1-oyl]rac-glycerol (MIPPAG) has been evaluated for this purpose. Materials and Methods: After oral administration, IPPA is released from the triglyceride by the action of pancreatic lipases followed by intestinal absorption and subsequent metabolism. Radioiodinated phenylpropenoic acid as the final metabolite of IPPA is then conjugated and excreted into the urine. We investigated 7 normal volunteers, 13 patients without signs of pancreatic disease and 23 patients with pancreatic insufficiency (PI). About 1 MBq Iodine-131-MIPPAG were administered orally with subsequent urine collection for two 24 h periods. Blood samples were withdrawn after 1, 3, 6, and 24 hours. TLC analysis was performed on the serum lipid extracts. As a reference method for PI measurement of the elastase concentration in the feces was used. Results: Healthy subjects excreted 44.9% (SD: 7.5%) of the administered dose in the first 24 h and after 48 h this value cumulated to 61.9 % (SD: 8.1%) whereas patients with PI excreted 27.5% (SD: 15.4%) and 35.0% (SD: 18.7%), respectively. These values were statistically highly significant (p<0.00001) compared to normals. The TLC's showed two major peaks which corresponded to the standards iodine benzoic acid (IBA) and tripalmitin (TP). The IBA/TP ratio increased with time. The sensitivity and specificity of this new test was 78.3% and 100%, respectively. Sensitivity of the elastase test was only 54%. Conclusion: MIPPAG showed the expected physiologic behavior and a pancreatic insufficiency might be diagnosed by a simple urine analysis after oral application of this new tracer

  17. Especificação e Implementação de Templates GDMO e Tipos ASN 1 para Linguagem C++

    Junior, Rivalino Matias; Specialski, Elizabeth Sueli; May, Karina; Ropelato, Patricia

    1996-01-01

    Este artigo descreve a especificação e implementação de regras para o mapeamento de templates GDMO (GuideUnes lor the Definition 01 Managed Objects) [1 l, além da implementação dos tipos ASN.1, em linguagem de programação C++[2l. Estas regras serao utilizadas no mapeamentotemplate - GDMO para classes (dass) em C++, linguagem utilizada em todo o projeto da Plataforma de Gerencia da Rede Local UFSC, a qual segue o modelo de gerenciamento de redes OSI.

  18. Especificação e análise de sistemas através de gramática de grafos

    Marcos Antonio de Oliveira Junior

    2016-01-01

    O crescimento da complexidade e do tamanho dos sistemas computacionais atuais suscitou um aumento na dificuldade de extração e especificação de modelos formais desses sistemas, tornando essa atividade cada vez mais dispendiosa, tanto em tempo quanto em custo. Modelos são utilizados em diversas técnicas da Engenharia de Software, com o intuito de auxiliar em processos que compreendem desde o desenvolvimento de novos softwares, até reconstrução de um sistema a partir de software legado, passand...

  19. Financial impact of outpatient clinic radioiodine therapy with sodium iodide I-131 for the treatment of patients with differentiated low-risk thyroid carcinoma in relation to hospital doses

    Berenguer, P.F.; Chang, T.M.C.; Silva, R.A.M.; Neto, A.H.D.; Belo, I.B.; Santos, M.A.P.

    2017-01-01

    Differential thyroid carcinoma (CDT) is the most prevalent endocrine malignancy in the world, with an excellent prognosis and a 10-year survival rate of over 95%. By 2013, the lowest activity of I-131 authorized by the Brazilian Unified Health System (SUS) in the therapy of patients with low-risk CDT was 3,700 MBq, requiring hospitalization. Recent studies have shown similar effectiveness between low and high doses of I-131 in the treatment of low-risk CDT. In 2014, the Ministry of Health included in the list of SUS procedures the use of lower activities (1,110 MBq and 1,850 MBq) for this purpose. The Brazilian National Nuclear Energy Commission (CNEN) also authorized the outpatient use of activity up to 1,850 MBq of I-131. Objective: To evaluate the financial impact of the adoption of ambulatory radioiodine therapy in patients with CDT of low-risk when compared to the hospital dose. Methods: Analysis of patients with CDT low-risk who were treated with an outpatient dose of I-131 from August / 2014 to January / 2017 at a nuclear medicine service in Recife, PE, Brazil. The cost of outpatient versus hospital doses was calculated. Results: A total of 289 patients underwent low doses of iodine therapy were evaluated, resulting in a savings of R$227,793.80. Conclusion: Outpatient radioiodine therapy in the treatment of patients with CDT of low-risk resulted in a 61.10% reduction in SUS expense, in addition to enabling faster care

  20. Tratamiento de la Enfermedad de Graves con I131: Primeros casos en la Unidad de Endocrinología Pediátrica del Hospital Nacional Cayetano Heredia, Lima-Perú: Case Report.

    Javier Ernesto SÁNCHEZ POVIS

    2006-01-01

    Full Text Available Objetivo: Describir la respuesta al tratamiento con I131 y sus complicaciones, en niños y adolescentes con enfermedad de Graves. Material y Métodos: Se estudiaron retrospectivamente las historias clínicas de los pacientes con diagnóstico de enfermedad de Graves y que recibieron tratamiento con I131 atendidos hasta 1999 en la Unidad de Endocrinología Pediátrica del Hospital Nacional Cayetano Heredia. Se registraron datos demográficos, peso tiroideo, captación de yodo, dosis de I131 recibida y evolución clínica y de función tiroidea. Resultados: Se incluyeron 13 pacientes: 1 varón y 12 mujeres. El peso glandular promedio obtenido fue 47,56 +10,70 gramos. La dosis inicial calculada fue 3,92 + 0,95 mCi, con un total de 4,47 + 1,66 mCi y tiempo medio de seguimiento de 2,76 años. Diez pacientes recibieron 1 sola dosis, 2 pacientes dos dosis y un paciente tres dosis, remitiendo el 100%. Los pacientes que recibieron una sola dosis, mostraron remisión del cuadro en 13,13 semanas y el tiempo promedio de remisión de toda la muestra fue 24,62 semanas. La prevalencia de hipotiroidismo a los 6 meses de iniciado el tratamiento fue 66,66%, y 83,33% a las 257 semanas. Conclusión: I131 fue 100% eficaz en el tratamiento de la enfermedad de Graves de los niños y adolescentes en esta pequeña serie de casos. (Rev Med Hered 2006;17:8-14.

  1. Financial impact of outpatient clinic radioiodine therapy with sodium iodide I-131 for the treatment of patients with differentiated low-risk thyroid carcinoma in relation to hospital doses; Impacto financeiro da radioiodoterapia ambulatorial com iodeto de sódio I-131 para tratamento de pacientes com carcinoma diferenciado da tireóide de baixo risco em relação às doses hospitalares

    Berenguer, P.F.; Chang, T.M.C.; Silva, R.A.M.; Neto, A.H.D.; Belo, I.B., E-mail: pricilaberenguer@gmail.com [Instituto de Medicina Integral Professor Fernando Figueira, Recife, PE (Brazil). Serviço de Medicina Nuclear; Santos, M.A.P. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife (Brazil). Coordenação de Radioproteção

    2017-07-01

    Differential thyroid carcinoma (CDT) is the most prevalent endocrine malignancy in the world, with an excellent prognosis and a 10-year survival rate of over 95%. By 2013, the lowest activity of I-131 authorized by the Brazilian Unified Health System (SUS) in the therapy of patients with low-risk CDT was 3,700 MBq, requiring hospitalization. Recent studies have shown similar effectiveness between low and high doses of I-131 in the treatment of low-risk CDT. In 2014, the Ministry of Health included in the list of SUS procedures the use of lower activities (1,110 MBq and 1,850 MBq) for this purpose. The Brazilian National Nuclear Energy Commission (CNEN) also authorized the outpatient use of activity up to 1,850 MBq of I-131. Objective: To evaluate the financial impact of the adoption of ambulatory radioiodine therapy in patients with CDT of low-risk when compared to the hospital dose. Methods: Analysis of patients with CDT low-risk who were treated with an outpatient dose of I-131 from August / 2014 to January / 2017 at a nuclear medicine service in Recife, PE, Brazil. The cost of outpatient versus hospital doses was calculated. Results: A total of 289 patients underwent low doses of iodine therapy were evaluated, resulting in a savings of R$227,793.80. Conclusion: Outpatient radioiodine therapy in the treatment of patients with CDT of low-risk resulted in a 61.10% reduction in SUS expense, in addition to enabling faster care.

  2. Um índice de capacidade para especificações unilaterais Process capability index for one-sided specification limit

    Gladys D. Cacsire Barriga

    2003-01-01

    Full Text Available Nos últimos anos, índices de capacidade de processos têm sido usados freqüentemente para determinar se um processo é capaz de produzir itens em conformidade com a tolerância especificada. No entanto, poucos estudos têm sido feitos acerca de índices de capacidade para situações em que há apenas um limite de especificação. Neste trabalho, um índice para situações em que há apenas um limite de especificação é apresentado. Ele é invariante com respeito à fração não-conforme do processo e "calibrado" pelo índice Cpk,. São desenvolvidos também aspectos inferenciais, do ponto de vista bayesiano, para amostragem binomial.Process capability indices have become popular tools to describe how well a process can meet specified tolerances. However, little attention has been given to the study of these indices when the specified tolerances are one-sided. In this work we present an index for such situations. The proposed index is invariant with respect to process fraction non-conforming and it is "Cpk calibrated". Bayesian inference procedure under a binomial sampling is also developed and described for the proposed index.

  3. Organ S values and effective doses for family members exposed to adult patients following I-131 treatment: A Monte Carlo simulation study

    Han, Eun Young [Department of Radiation Oncology, University of Arkansas Medical Sciences, Little Rock, Arkansas 72205 (United States); Lee, Choonsik [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, Bethesda, Maryland 20852 (United States); Mcguire, Lynn; Brown, Tracy L. Y. [Department of Radiology, Division of Nuclear Medicine, University of Arkansas Medical Sciences, Little Rock, Arkansas 72205 (United States); Bolch, Wesley E. [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States)

    2013-08-15

    Purpose: To calculate organ S values (mGy/Bq-s) and effective doses per time-integrated activity (mSv/Bq-s) for pediatric and adult family members exposed to an adult male or female patient treated with I-131 using a series of hybrid computational phantoms coupled with a Monte Carlo radiation transport technique.Methods: A series of pediatric and adult hybrid computational phantoms were employed in the study. Three different exposure scenarios were considered: (1) standing face-to-face exposures between an adult patient and pediatric or adult family phantoms at five different separation distances; (2) an adult female patient holding her newborn child, and (3) a 1-yr-old child standing on the lap of an adult female patient. For the adult patient model, two different thyroid-related diseases were considered: hyperthyroidism and differentiated thyroid cancer (DTC) with corresponding internal distributions of {sup 131}I. A general purpose Monte Carlo code, MCNPX v2.7, was used to perform the Monte Carlo radiation transport.Results: The S values show a strong dependency on age and organ location within the family phantoms at short distances. The S values and effective dose per time-integrated activity from the adult female patient phantom are relatively high at shorter distances and to younger family phantoms. At a distance of 1 m, effective doses per time-integrated activity are lower than those values based on the NRC (Nuclear Regulatory Commission) by a factor of 2 for both adult male and female patient phantoms. The S values to target organs from the hyperthyroid-patient source distribution strongly depend on the height of the exposed family phantom, so that their values rapidly decrease with decreasing height of the family phantom. Active marrow of the 10-yr-old phantom shows the highest S values among family phantoms for the DTC-patient source distribution. In the exposure scenario of mother and baby, S values and effective doses per time-integrated activity to

  4. Radiation dosimetry and first therapy results with a 124I/131I-labeled small molecule (MIP-1095) targeting PSMA for prostate cancer therapy

    Zechmann, Christian M.; Afshar-Oromieh, Ali; Mier, Walter; Armor, Tom; Joyal, John; Stubbs, James B.; Hadaschik, Boris; Kopka, Klaus; Debus, Juergen; Babich, John W.; Haberkorn, Uwe

    2014-01-01

    Since the prostate-specific membrane antigen (PSMA) is frequently over-expressed in prostate cancer (PCa) several PSMA-targeting molecules are under development to detect and treat metastatic castration resistant prostate cancer (mCRPC). We investigated the tissue kinetics of a small molecule inhibitor of PSMA ((S)-2-(3-((S)-1-carboxy-5-(3-(4-[ 124 I]iodophenyl)ureido)pentyl)ureido) pentan edioicacid; MIP-1095) using PET/CT to estimate radiation dosimetry for the potential therapeutic use of 131 I-MIP-1095 in men with mCRPC. We also report preliminary safety and efficacy of the first 28 consecutive patients treated under a compassionate-use protocol with a single cycle of 131 I-MIP-1095. Sixteen patients with known prostate cancer underwent PET/CT imaging after i.v. administration of 124 I-MIP-1095 (mean activity: 67.4 MBq). Each patient was scanned using PET/CT up to five times at 1, 4, 24, 48 and 72 h post injection. Volumes of interest were defined for tumor lesions and normal organs at each time point followed by dose calculations using the OLINDA/EXM software. Twenty-eight men with mCRPC were treated with a single cycle of 131 I-MIP-1095 (mean activity: 4.8 GBq, range 2 to 7.2 GBq) and followed for safety and efficacy. Baseline and follow up examinations included a complete blood count, liver and kidney function tests, and measurement of serum PSA. I-124-MIP-1095 PET/CT images showed excellent tumor uptake and moderate uptake in liver, proximal intestine and within a few hours post-injection also in the kidneys. High uptake values were observed only in salivary and lacrimal glands. Dosimetry estimates for I-131-MIP-1095 revealed that the highest absorbed doses were delivered to the salivary glands (3.8 mSv/MBq), liver (1.7 mSv/MBq) and kidneys (1.4 mSv/MBq). The absorbed dose calculated for the red marrow was 0.37 mSv/MBq. PSA values decreased by >50 % in 60.7 % of the men treated. Of men with bone pain, 84.6 % showed complete or moderate reduction in pain

  5. Organ S values and effective doses for family members exposed to adult patients following I-131 treatment: A Monte Carlo simulation study

    Han, Eun Young; Lee, Choonsik; Mcguire, Lynn; Brown, Tracy L. Y.; Bolch, Wesley E.

    2013-01-01

    Purpose: To calculate organ S values (mGy/Bq-s) and effective doses per time-integrated activity (mSv/Bq-s) for pediatric and adult family members exposed to an adult male or female patient treated with I-131 using a series of hybrid computational phantoms coupled with a Monte Carlo radiation transport technique.Methods: A series of pediatric and adult hybrid computational phantoms were employed in the study. Three different exposure scenarios were considered: (1) standing face-to-face exposures between an adult patient and pediatric or adult family phantoms at five different separation distances; (2) an adult female patient holding her newborn child, and (3) a 1-yr-old child standing on the lap of an adult female patient. For the adult patient model, two different thyroid-related diseases were considered: hyperthyroidism and differentiated thyroid cancer (DTC) with corresponding internal distributions of 131 I. A general purpose Monte Carlo code, MCNPX v2.7, was used to perform the Monte Carlo radiation transport.Results: The S values show a strong dependency on age and organ location within the family phantoms at short distances. The S values and effective dose per time-integrated activity from the adult female patient phantom are relatively high at shorter distances and to younger family phantoms. At a distance of 1 m, effective doses per time-integrated activity are lower than those values based on the NRC (Nuclear Regulatory Commission) by a factor of 2 for both adult male and female patient phantoms. The S values to target organs from the hyperthyroid-patient source distribution strongly depend on the height of the exposed family phantom, so that their values rapidly decrease with decreasing height of the family phantom. Active marrow of the 10-yr-old phantom shows the highest S values among family phantoms for the DTC-patient source distribution. In the exposure scenario of mother and baby, S values and effective doses per time-integrated activity to the

  6. Comparison of chromatography and Sep-pak methods for estimating the radiochemical purity of I-123 and I-131 labelled meta-iodobenzylguanidine (mIBG), synthesised in house

    Kumar, V.

    1998-01-01

    Full text: Radioiodine (I-123 or I-131) labelled mlBG has been prepared routinely in-house in a number of radiopharmacy laboratories. The radiochemical purity can be estimated by several methods. Available literature suggests that the results of chronatographic analysis are comparable with electrophoresis and high pressure liquid chromatography (HPLC) methods which are considered as gold-standard procedures. However, due to the cost involved with these equipments most of the radiopharmacy laboratories are not fortunate enough to have them. The present study compares the validity of reverse-phase Sep-pak cartridge method against chromatographic technique. We analysed twenty four preparations of mIBG by both Sep-pak and chromatography methods (20 batches of I-123 mD3G and 4 batches of I-131 mIBG). Chromatographic analysis, which takes >2hrs, was performed with Whatman No 1/ n-butanol: acetic acid: water (60:15:25 v/v) and the activity associated with the peaks for free iodine and I-123 mD3G were measured. Sep-pak cartridge method, which takes less than 10 min, was performed as follows: the cartridge was activated by injecting 5 mL ethanol (200% pure) followed by flushing with 5mL distilled water. A sample (0.1mL) of radioiodine labelled mD3G was applied to the column and was eluted with 5mL distilled water. Subsequently two aliquots of 5mL solution containing tetrahydrofuran: (0.1M) sodium dihydrogen phosphate (25:75v/v) were passed through and the activity in each elute was measured. Analysing the results by Student's paired t-test for I-123 mlBG using the Sep-pak method gave a mean + SD of 98.8+ 0.6 % which correlated well (r 2 = 0.780) with the results obtained by the chromatographic method 99.3+0.5% (p <0.05). The results obtained for free I-123 by the two methods were 1.09 + 0.56% and 0.6 + 0.5% (p <0.05) respectively. The parameters did not differ significantly when I-131, instead of I-123, was used to synthesise mIBG. The results clearly indicate that the Sep

  7. Randomised Phase I/II trial assessing the safety and efficacy of radiolabelled anti-carcinoembryonic antigen I131 KAb201 antibodies given intra-arterially or intravenously in patients with unresectable pancreatic adenocarcinoma

    Sultana, Asma; Garvey, Conall; Sutton, Robert; Neoptolemos, John P; Ghaneh, Paula; Shore, Susannah; Raraty, Michael GT; Vinjamuri, Sobhan; Evans, Jonathan E; Smith, Catrin Tudur; Lane, Steven; Chauhan, Seema; Bosonnet, Lorraine

    2009-01-01

    Advanced pancreatic cancer has a poor prognosis, and the current standard of care (gemcitabine based chemotherapy) provides a small survival advantage. However the drawback is the accompanying systemic toxicity, which targeted treatments may overcome. This study aimed to evaluate the safety and tolerability of KAb201, an anti-carcinoembryonic antigen monoclonal antibody, labelled with I 131 in pancreatic cancer (ISRCTN 16857581). Patients with histological/cytological proven inoperable adenocarcinoma of the head of pancreas were randomised to receive KAb 201 via either the intra-arterial or intravenous delivery route. The dose limiting toxicities within each group were determined. Patients were assessed for safety and efficacy and followed up until death. Between February 2003 and July 2005, 25 patients were enrolled. Nineteen patients were randomised, 9 to the intravenous and 10 to the intra-arterial arms. In the intra-arterial arm, dose limiting toxicity was seen in 2/6 (33%) patients at 50 mCi whereas in the intravenous arm, dose limiting toxicity was noted in 1/6 patients at 50 mCi, but did not occur at 75 mCi (0/3). The overall response rate was 6% (1/18). Median overall survival was 5.2 months (95% confidence interval = 3.3 to 9 months), with no significant difference between the intravenous and intra-arterial arms (log rank test p = 0.79). One patient was still alive at the time of this analysis. Dose limiting toxicity for KAb201 with I 131 by the intra-arterial route was 50 mCi, while dose limiting toxicity was not reached in the intravenous arm

  8. Clinical outcome during the peri-operative (thyroidectomy) period of severely hyperthyroid patients with normalized pre-operative free-T4 levels: Importance of I-131 therapy as a part of pre-operative preparation

    Siguan-Crisaldo, M.A.L.; Mercado-Asis, L.B.

    2005-01-01

    Thyroidectomy is performed for hyperthyroidism on patients who do not respond to or are not compliant with medical therapy and in patients with very large goiters causing compressive symptoms. All thyrotoxic patients undergoing thyroidectomy usually are first treated with anti-thyroid drugs to normalize free thyroid hormone levels and render them euthyroid before surgery in order to prevent complications particularly thyroid storm and circulatory collapse. In this case series, we describe the clinical outcome during the perioperative (thyroidectomy) period of three severely hyperthyroid patients, two females and one male, with ages ranging from 13 to 38 years. All patients had grade III goiter, and only one had exophthalmos. The mean duration of goiter was 3.6 years. All of them were given preoperative treatment consisting of propylthiouracil (PTU) at 450-600 mg/day; iodone, 3 tablets daily and propranolol at 30-120 mg/day for one month. All of them had normalized preoperative thyroid function tests. In addition to the preoperative medications mentioned above, all three patients received radioactive iodine therapy before surgery. The first two patients received relatively low doses of 8.0 and 7.5 mCi of I-131 respectively. Unfortunately the first patient had supraventricular tachycardia (SVT), post skin cutting and the other one went into thyroid storm. The third patient who received a cumulative dose of 23.5 mCi of I-131 before surgery had an uneventful postoperative course. It is concluded that normalization of thyroid hormone parameters, especially free T4 is not sufficient for an uneventful and uncomplicated peri-thyroidectomy period in severely hyperthyroid patients with large goiters. Effective radioactive iodine therapy might prove to be helpful in inducing thyroid tissue fibrosis, thus leading to true clinical euthyroidism and excellent clinical course postoperatively. (author)

  9. Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan

    Jeong, Hwan Jeong; Lim, Seok Tae; Youn, Hyun Jo; Sohn, Myung-Hee

    2008-01-01

    Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Fifty eight patients (M:F=13;45, age 44.5±11.5 yrs) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, forty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were 154±25 mCi in stage I (n=9), 175±50 mCi in stage II (n=4), 149±21 mCi in stage III (n=38), and 161±20 mCi in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with 149±26 mCi of I-131, 9 patients (17.3%) having 2≤ sTG <5 ng/mL with 156±17 mCi, 5 patients (9.6%) having 5≤ sTG <10 ng/mL with 156±13 mCi, 7 patients (13.5%) having 10≤ sTG <50 ng/mL with 147±24 mCi, and 6 patients (11.5%) having above 50 ng/mL with 175±42 mCi. The statistical significance between sTG level and TD (p=0.252) was not shown. In conclusion, PS and sTG could not replace the

  10. Properties of pre-cast terrazzo tiles and recommended specifications Propriedades de telhas de terrazzo pré-moldadas e especificações recomendadas

    G. Karam

    2009-03-01

    Full Text Available A targeted experimental program was carried out to establish basic reference physical and mechanical properties of commercially available pre-cast marble chip terrazzo tiles and to investigate the effects of varying manufacturing process parameters on those properties. The transverse strength, density, water absorption, and abrasion resistance were measured as a function of casting pressure and residence time in the casting mold for a standard mix design. A simple surface abrasion index test was developed and applied comparing pre-cast terrazzo tiles with reference natural tiling stones. Recommendations for improving existing specifications and developing quality control measures are presented.Foi feito um programa experimental direcionado para estabelecer propriedades físicas e mecânicas como referências básicas de telhas de terrazzo de peças de mármore pré-moldadas disponíveis comercialmente e para investigar os efeitos de vários parâmetros de processo de fabricação nessas propriedades. A resistência transversal, a densidade, a absorção de água e a resistência ao desgaste foram medidas em função da pressão de moldagem e do tempo de residência do molde de um projeto de mistura padrão. Um teste simples de índice de desgaste de superfície foi desenvolvido e aplicado na comparação de telhas de terrazzo pré-moldadas com pedras de telhas naturais de referência. As recomendações para a melhoria das especificações existentes e o desenvolvimento de medidas para controle de qualidade são apresentadas.

  11. Sistemas de equações de demanda por carnes no Brasil: especificação e estimação

    Moisés de Andrade Resende Filho

    2012-03-01

    Full Text Available Especificações alternativas do sistema de demanda quase ideal (AIDS foram utilizadas para estimar as demandas agregadas das carnes bovina, suína e de frango e outros bens de consumo e as suas elasticidades no Brasil. Detectada a necessidade de se utilizar a variável tendência nas equações dos modelos, observou-se uma tendência de crescimento da demanda por carnes e de decrescimento da demanda por outros bens de consumo. A variável dummy para o Plano Real indicou que o mesmo não afetou as demandas. Com base nas elasticidades próprios-preços Marshallianas, as demandas por carnes são inelásticas e a demanda por outros bens de consumo é elástica. As elasticidades preços-cruzados Marshallianas e Hicksianas confirmaram que as carnes bovina, suína e de frango são bens substitutos. As elasticidades-gasto indicaram que todos os bens são normais, exceto a carne suína que é um bem inferior. Como é provável que o gasto com o consumo das famílias aumente ao longo do tempo, ceteris paribus, as elasticidades gasto indicam que a demanda por carnes perderá importância para os outros bens de consumo, que o consumo de carne bovina perderá importância para a carne de frango e que o consumo de carne de porco perderá importância para as outras carnes.

  12. Intercomparison Of Activity Measurements Of Co-58, Y-88, Ho-166m, Tc-99m, dan I-131 Between P3KRBiN and Laboratory Within BATAN And Hospitals

    Nazaroh; Ermi-Juita; Hermawan-Candra

    2003-01-01

    One way to maintain traceability and to keep consistency of the measurement result of radioactivity was intercomparison program. According with Surat Keputusan Kepala BATAN No.73/KA/IV/99, one of tasks and functions of standardization laboratory is to coordinate an intercomparison program of radioactivity measurement. In the year of 2000, intercomparison program of activity measurements between P3KRBiN and 10 laboratories within BATAN and 12 hospitals were carried out. For intercomparison of Co-58, Y-88, and Ho-166m, there were 3 laboratories within BATAN which have more than 50% difference compared with P3KRBiN measurements and for intercomparison of Tc-99m, dan I-131, there were 2 Dose-Calibrators belongs to hospitals which have more than 30% difference compared with P3KRBiN measurements. From that result it can be concluded that intercomparison of activity measurements are very important and needs continuously to maintain traceability and to keep consistency of measurement result. (author)

  13. Department of Homeland Security (DHS I-131)

    Social Security Administration — This identifies resident aliens who should have their Supplemental Security Income benefit payment suspended because they have voluntarily left the United States for...

  14. Determination of I-131 in milk samples

    Fernandez G, I.; Rodriguez C, G.; Quevedo A, J. L.

    1996-01-01

    In our country, in the near future, an isotope center will be in operation, and due to its characteristics, it is possible the discharge of radionuclides to the atmosphere during its normal exploitation, as well as in case of accident. Considering the kind and the concentration of the radioactive material released to the atmosphere, the possible ways of contamination were determined, playing the milk the most significant role, because the Iodine-131 is in the radionuclide inventory of this center, being possible to pass to the food-chain soil-grass-milk, due to the fact that the center is located in a cattle zone. Owing to these facts, it is necessary to rely on a method for determining Iodine-131 that allows to control its presence in milk samples, when the isotope center start to operate. The direct absorption of Iodine-131 in an anionic exchange resin and the subsequent analysis of this resin for gamma spectrometry with a Nal (Tl) detector is a cheap, simple and fast method with a recovery average greater than the 95%. (authors). 5 refs., 3 tabs

  15. Adaptive software synthesis from extended dataflow specifications = Síntese de Software Adaptativo baseada em Especificações Extended Dataflow

    Ivanilton Polato

    2005-07-01

    Full Text Available Embedded software development approaches used models of computationsuch as dataflow, discrete events, synchronous/reactive, among others. Due to the specialization of the existing models, each one can be better applied to a specific application domain. Nevertheless, when there is no solution for applications in a specific domain,heterogeneous models have been used. In this context, this paper discusses a heterogeneous model called Extended Dataflow. It is an extension of the dataflow model with support to event handling. This paper also addresses how software can be synthesized from extendeddataflow specifications and discusses the development of a code generation tool prototype. This takes into account the possibility of component reuse for developing digital signal processing applications. A case study of adaptative applications using digital filters is used to illustrate our approach.As abordagens de desenvolvimento de software embutido têm feito o uso de modelos de computação, tais como fluxo de dados, eventos discretos, síncrono/reativo, dentre outros. A especialização desses modelos faz com que sejam apropriados a um domínio específico de aplicações. Entretanto, quando não existe uma solução adequada paradeterminada aplicação, os modelos heterogêneos têm sido utilizados. Neste contexto, este artigo discute um modelo heterogêneo, chamado Extended Dataflow, que é uma extensão do modelo de fluxo de dados com suporte ao tratamento de eventos. O artigo mostra ainda como um software pode ser obtido a partir de especificações usando Extended Dataflow e discute o desenvolvimento de um protótipo de ferramenta de geração de código. Isso leva em consideração a possibilidade de reuso de componentes em aplicações de processamento digital de sinais. Um estudo de caso sobre aplicações adaptativas envolvendo filtros digitais é utilizado para ilustrar o trabalho.

  16. APLICACIÓN DE UN SISTEMA DE COSTOS POR ÓRDENES ESPECIFICAS EN LA EMPRESA INVERSIONES VISTA ALEGRE SRL, PARA MEJORAR SU RENTABILIDAD, EN JOSÉ LEONARDO ORTIZ 2013.

    Balcazar Paiva, Eveling Sussety; Universidad Señor de Sipan, Chiclayo, Perú; Morales Gonzáles, Nathaly del Milagro; Universidad Señor de Sipan, Chiclayo, Perú

    2015-01-01

    La presente investigación se crea con el fin de dar solución a un problema que aqueja a la gran mayoría de pequeñas empresas en relación a la determinación de sus costos, pues como se ha podido establecer, estos entes operan sin saber si en realidad obtiene utilidad o no; por lo cual nosotras las investigadores no quisimos hacernos ajenas a este problema para lo cual pensamos que si aplicábamos un sistema de costeo por órdenes especificas entonces se podría mejorar la rentabilidad de la empre...

  17. Computational modeling of the mathematical dummy of the Brazilian woman for calculations of internal dosimetry and ends of comparison of the fractions absorbed specific with the woman reference; Modelagem computacional do manequim matematico da mulher brasileira para calculos de dosimetria interna e para fins de comparacao das fracoes absorvidas especificas com a mulher referencia

    Ximenes, Edmir

    2006-07-01

    Tools for dosimetric calculations are of the utmost importance for the basic principles of radiological protection, not only in nuclear medicine, but also in other scientific calculations. In this work a mathematical model of the Brazilian woman is developed in order to be used as a basis for calculations of Specific Absorbed Fractions (SAFs) in internal organs and in the skeleton, in accord with the objectives of diagnosis or therapy in nuclear medicine. The model developed here is similar in form to that of Snyder, but modified to be more relevant to the case of the Brazilian woman. To do this, the formalism of the Monte Carlo method was used by means of the ALGAM- 97{sup R} computational code. As a contribution to the objectives of this thesis, we developed the computational system cSAF - consultation for Specific Absorbed Fractions (cFAE from Portuguese acronym) - which furnishes several 'look-up' facilities for the research user. The dialogue interface with the operator was planned following current practices in the utilization of event-oriented languages. This interface permits the user to navigate by means of the reference models, choose the source organ, the energy desired, and receive an answer through an efficient and intuitive dialogue. The system furnishes, in addition to the data referring to the Brazilian woman, data referring to the model of Snyder and to the model of the Brazilian man. The system makes available not only individual data to the SAFs of the three models, but also a comparison among them. (author)

  18. Computational modeling of the mathematical dummy of the Brazilian woman for calculations of internal dosimetry and ends of comparison of the fractions absorbed specific with the woman reference; Modelagem computacional do manequim matematico da mulher brasileira para calculos de dosimetria interna e para fins de comparacao das fracoes absorvidas especificas com a mulher referencia

    Ximenes, Edmir

    2006-07-01

    Tools for dosimetric calculations are of the utmost importance for the basic principles of radiological protection, not only in nuclear medicine, but also in other scientific calculations. In this work a mathematical model of the Brazilian woman is developed in order to be used as a basis for calculations of Specific Absorbed Fractions (SAFs) in internal organs and in the skeleton, in accord with the objectives of diagnosis or therapy in nuclear medicine. The model developed here is similar in form to that of Snyder, but modified to be more relevant to the case of the Brazilian woman. To do this, the formalism of the Monte Carlo method was used by means of the ALGAM- 97{sup R} computational code. As a contribution to the objectives of this thesis, we developed the computational system cSAF - consultation for Specific Absorbed Fractions (cFAE from Portuguese acronym) - which furnishes several 'look-up' facilities for the research user. The dialogue interface with the operator was planned following current practices in the utilization of event-oriented languages. This interface permits the user to navigate by means of the reference models, choose the source organ, the energy desired, and receive an answer through an efficient and intuitive dialogue. The system furnishes, in addition to the data referring to the Brazilian woman, data referring to the model of Snyder and to the model of the Brazilian man. The system makes available not only individual data to the SAFs of the three models, but also a comparison among them. (author)

  19. Remodelagem do sistema computacional para dosimetria em radioterapia por nêutrons e fótons baseado em métodos estocásticos - SISCODES

    Bruno Machado Trindade

    2011-01-01

    O presente trabalho apresenta a remodelagem do Sistema Computacional para Dosimetria em Radioterapia por Nêutrons e Fótons Baseado em Métodos Estocásticos . SISCODES. Para isso mostra a proposta inicial e estado anterior do sistema, as modificações e expansões propostas e executadas, e o estado atual de desenvolvimento do sistema. Melhorias futuras são propostas ao final do trabalho. O SISCODES é um sistema que permite a execução de planejamento computacional 3D em radioterapia, através de si...

  20. Management of radioactive wastes from HNMD (Hospital Naval Marcilio Dias) and from IRD (Instituto de Radioprotecao e Dosimetria) due to the accident in Goiania

    Peres, S.S.; Silva, J.J.G.

    1988-01-01

    A description of the methods and procedures for the management of the radwastes from HNMD (Hospital Naval Marcilio Dias) and from IRD (Instituto de Radioprotecao e Dosimetria) due to the radioactive accident at Goiania City, is presented. Basically the radwastes are consituted by excreta of persons involved in the accident and materials used for medicals care of patients. The method employed for treatment of faeces was its aggregation in lime and cement and for the case of urine, ion exchange resing, was used. Others type of radwastes were compacted or simply conditionned. Many releases to the environment, were possible. (author) [pt

  1. Dosimetria e monitoração de feixes estreitos de raios-X, produzidos por acelerador linear de particulas, para aplicação em radiocirurgia

    Jose Carlos Ferraz de Campos

    1986-01-01

    Resumo: O presente trabalho teve como objetivo principal investigar as características principais de dosimetria e monitoração de feixes finos de raios-x, e sua aplicação a um Acelerador Linear de Partículas de 4 MV, para seu emprego na Radiocirurgia. Com esta finalidade, construiu-se um sistema de colimação adicional, composto de 3 colimadores de Chumbo, que permite, a partir do campo mínimo protocolar produzido pelo acelerador, obter os feixes finos de 6, 10 e 15 mm de diâmetros. Um siste...

  2. Analysis of the specific consumption of energy and of carbon specific emissions of the mexican Iron and steel industry; Analisis del consumo especifico de energia y de las emisiones especificas de carbono de la industria siderurgica mexicana

    Ozawa, L; Sheinbaum, C [Instituto de Ingenieria de la UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    From 1970 to 1995, the specific consumption of energy of the Mexican iron and steel industry diminished in 16.2%, and the specific carbon emissions in 21.8%. In order to analyze the factors that favored these diminutions, the specific energy consumption in structural changes and improvements in energy efficiency were segregated; whereas the specific carbon emissions were segregated in structural changes, improvements of energy efficiency, changes in the factors of carbon emissions and in the fuel mixture in the iron and steel industry as well as in the electricity generation. It was observed that the diminution in the specific consumption as well as in the specific carbon emissions were mainly due to technological improvements in the manufacture of the steel: the complete substitution of the open hearth furnaces and a comprehensive penetration of the continuous casting. In spite of these improvements in energy efficiency and to the gradual substitution of coke by natural gas when increasing the production of iron by direct reduction. Though, the emission factor of the electricity was increased due to a greater participation of the fossil plants in 1995 in comparison with 1970. The indicators of energy efficiency of this industry with other countries were compared taking into account their own structure. Finally recommendations are made of measures for energy saving. [Spanish] De 1970 a 1995, el consumo especifico de energia de la industria siderurgica mexicana disminuyo en un 16.2%, y las emisiones especificas de carbono en un 21.8%. Para analizar los factores que favorecieron dichas disminuciones, se desagrego el consumo especifico de energia en cambios estructurales y en mejoras de eficiencia energetica; mientras que las emisiones especificas de carbono se desagregaron en cambios estructurales, mejoras de eficiencia energetica, cambios en los factores de emision de carbono y en la mezcla de combustibles tanto de la industria siderurgica como en la generacion de

  3. Aspectos de especificação e implementação da camada de apresentação do padrão map utilizando o ambiente epos

    Paulo Cesar Minoru Inazumi

    1990-01-01

    Resumo: Este trabalho apresenta a implementacão do prolocolo de apresentacão do modelo OSI/ISO para o projelo SISDI-MAP (Sislema Didático MAP). Utilizou-se o ambiente EPOS ("Engineering Project Oriented System") como suporte de desenvolvimento principalmente para a especificação formal da implementação e geração automática de código. Apresentam-se os conceitos referentes à camada de apresentação, o modelo de implementação, alguns aspectos da implementação e da geração automática de código e, ...

  4. Methodology to administer therapeutic dose of I-131; Metodologia para administrar dosis terapeutica de I-131

    Basteris M, J.; Gomez D, R. [Universidad Autonoma de Yucatan, Facultad de Medicina, Merida, Yucatan (Mexico)

    2007-07-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment of the thyroid cancer with Iodine-131, as well as the use of citric fruits to stimulate the salivation, the post-dose administration of liquids to accelerate the gastric emptying avoiding the secondary effects as the vomit is included. (Author)

  5. Introdução à nova linguagem ISO de especificação geométrica de produtos - Parte I: A classificação dos elementos geométricos de superfície e suas aplicações

    José António Almacinha

    2005-01-01

    Neste artigo, o primeiro de uma série de dois sobre os fundamentos da nova linguagem ISO de Especificação geométrica de produtos, baseada numa matematização dos conceitos e utilizável em concepção, fabricação e verificação, assinala-se o papel relevante desempenhado pelos elementos geométricos de superfície na especificação de produtos. Apresenta-se uma classificação dos elementos geométricos desenvolvida a partir da noção de simetria e extensível às ligações cinemáticas entre dois corpos. Mo...

  6. Sistema computacional para dosimetria de nêutrons e fótons baseado em métodos estocásticos aplicado a radioterapia e radiologia

    Bruno Machado Trindade

    2011-04-01

    Full Text Available OBJETIVO: Este artigo mostra um procedimento de conversão de imagens de tomografia computadorizada ou de ressonância magnética em modelo de voxels tridimensional para fim de dosimetria. Este modelo é uma representação personalizada do paciente que pode ser usado na simulação, via código MCNP (Monte Carlo N-Particle, de transporte de partículas nucleares, reproduzindo o processo estocástico de interação de partículas nucleares com os tecidos humanos. MATERIAIS E MÉTODOS: O sistema computacional desenvolvido, denominado SISCODES, é uma ferramenta para planejamento computacional tridimensional de tratamentos radioterápicos ou procedimentos radiológicos. Partindo de imagens tomográficas do paciente, o plano de tratamento é modelado e simulado. São então mostradas as doses absorvidas, por meio de curvas de isodoses superpostas ao modelo. O SISCODES acopla o modelo tridimensional ao código MCNP5, que simula o protocolo de exposição à radiação ionizante. RESULTADOS: O SISCODES vem sendo utilizado no grupo de pesquisa NRI/CNPq na criação de modelos de voxels antropomórficos e antropométricos que são acoplados ao código MCNP para modelar braquiterapias e teleterapias aplicadas a tumores em pulmões, pelve, coluna, cabeça, pescoço, e outros. Os módulos atualmente desenvolvidos no SISCODES são apresentados junto com casos exemplos de planejamento radioterápico. CONCLUSÃO: O SISCODES provê de maneira rápida a criação de modelos de voxels personalizados de qualquer paciente que podem ser usados em simulações por códigos estocásticos tipo MCNP. A combinação da simulação via MCNP com um modelo personalizado do paciente traz grandes melhorias na dosimetria de tratamentos radioterápicos.

  7. Personal monitoring services available at Institute for Radiation Protection of ENEA; Il servizo di dosimetria personale dell'Istituto per la Radioprotezione dell'ENEA

    Fantuzzi, E.; Bonarelli, T. [ENEA Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1999-07-01

    Personnel monitoring provides the means to measure and record the radiation doses received by individual workers. The ionising radiation decree (230/95) set out the circumstances when the assessment and recording of person's exposure is legally required. Many employers issue dosemeters to staff even though there is no legal requirement to do so. This may be part of a quality assurance programme or as a reassurance measure. Dosemeter readings will serve to ensure compliance with legal dose limits and assure the employer that radiation exposure is as low as reasonably achievable. The ENEA (National Agency for New Technology, Energy and the Environment) IRP (Institute for Radiation Protection) individual monitoring service has been running for over 30 years. It offers personnel dosemeters which are based on its expertise and backed up by continual research and development. The report provides details of the dosemeters in use at IRP enable to decide which ones most suit the needs and shows IMS's organisation, customer and communications, dose reports form and administrative items. A short mention of future development will also be given. [Italian] La dosimetria individuale fornisce gli strumenti per misurare e registrare le dosi da radiazioni ionizzanti ricevute dai lavoratori esposti. Il decreto legislativo 230/95 stabilisce le circostanze in cui il monitoraggio individuale e' legalmente richiesto. Molti datori di lavoro forniscono dosimetri individuali anche quando non vi e' una richiesta legale spesso per seguire le regole di un programma di assicurazione di qualita' relativo alla radioprotezione o per ottenere una conferma che il principio ALARA sia soddisfatto. Il servzio di dosimetria personale dell'Istituto per la Radioprotezione dell'ENEA e' attivo da oltre 30 anni e offre dosimetri sviluppati sulla propria esperienza nelle tecniche dosimetriche che vengono continuamente aggiornati e adeguati rispecchiando lo stato dell

  8. Biological dosimetry of patients with differenced carcinoma of thyroid treated with Iodine-131; Dosimetria biologica de pacientes con carcinoma diferenciado de tiroides tratados con Iodo-131

    Vallerga, M. B.; Rojo, A.M.; Taja, M.R.; Deluca, G.; Di Giorgio, M. [Autoridad Regulatoria Nuclear Av. Del Libertador 8250 (C1429BNP). Buenos Aires (Argentina); Fadel, A. [Hospital General de Agudos Dr. Carlos Durand Av. Diaz Velez 5044. Buenos Aires (Argentina); Cabrejas, M.; Valdivieso, C. [Hospital de Clfnicas Jose de San Martin Av. Cordoba 2351 (CP1120). Buenos Aires (Argentina)]. e-mail: mvallerg@cae.arn.gov.ar

    2006-07-01

    The administration of I-131 to patient with Differentiated Thyroid Carcinoma (CaDiT) it is used inside the therapeutic outline as later step to the thyroidectomy. However, the good activity to give is of difficult determination due to factors such as, the variability in the capacity of tumoral reception of the I-131, distribution of the pharmaceutical, physiologic status, other associate pathologies, grade of advance of the illness, and previous treatments. Additionally, the activity to administer is dependent of the dose of tolerance in the healthy tissues; superior dose to 2 Gy in bone marrow, its could drive to myelotoxicity. At the moment, the form more extended of administration it is the empiric prescription that considers clinical parameters and of laboratory for their determination. Presently work, the protocol of applied treatment incorporates the evaluation for internal dosimetry and biological dosimetry to estimate absorbed dose in bone marrow. The biological estimate of the dose of these patients is based on the quantification of chromosomal aberrations whose frequency is referred to a curve-dose response in which the lymphocytes is irradiated in vitro with I-131, allowing to determine the in vivo dose to the patient's circulating lymphocytes. The objective of the present work is to determine the applicability of different cytogenetic essays in the estimate of the absorbed dose to the whole body or specific organs. Three patients were evaluated with CaDiT. Their treatment protocol consisted on a tracer administration of radioactive iodine of 74 - 111 MBq (2 - 3 mCi) and a therapy 7,4 - 11,1 GBq (200 - 300 mCi). Previous to the tracer administration and 8 days post-therapeutic administration took samples of veined blood that were evaluated by biological dosimetry by means of the application of the techniques: conventional cytogenetic Micronucleus and FISH (Hybridization in situ by Fluorescence). Starting from the frequencies of observed chromosomal

  9. Aplicativo para dosimetria interna usando a distribuição biocinética de fótons baseada em imagens de medicina nuclear

    Viriato Leal Neto

    2014-10-01

    Full Text Available Objetivo: Este artigo apresenta uma forma de se obterem estimativas de dose em pacientes submetidos a tratamentos radioterápicos a partir da análise das regiões de interesse em imagens de medicina nuclear. Materiais e Métodos: Foi desenvolvido o software denominado DoRadIo (Dosimetria das Radiações Ionizantes, que recebe as informações sobre os órgãos fontes e o órgão alvo e retorna resultados gráficos e numéricos. As imagens de medicina nuclear utilizadas foram obtidas de catálogos disponibilizados por físicos médicos. Nas simulações utilizaram-se modelos computacionais de exposição constituídos por fantomas de voxels acoplados ao código Monte Carlo EGSnrc. O software foi desenvolvido no Microsoft Visual Studio 2010 com o modelo de projeto Windows Presentation Foundation e a linguagem de programação C#. Resultados: Da aplicação das ferramentas foram obtidos: o arquivo para otimização das simulações Monte Carlo utilizando o EGSnrc, a organização e compactação dos resultados dosimétricos com todas as fontes, a seleção das regiões de interesse, a contagem da intensidade dos tons de cinza nas regiões de interesse, o arquivo das fontes ponderadas e, finalmente, todos os resultados gráficos e numéricos. Conclusão: A interface de usuários pode ser adaptada para uso em clínicas de medicina nuclear como ferramenta computacional auxiliar na estimativa da atividade administrada.

  10. [Efficacy of treatment with I(131) in paediatric Graves disease].

    Enes Romero, P; Martín-Frías, M; de Jesús, M; Caballero Loscos, C; Alonso Blanco, M; Barrio Castellanos, R

    2014-01-01

    Radioiodine is an important therapeutic option in young patients with Grave's disease (GD). In the United States it is a widespread therapy, but in Europe its use in paediatrics is still controversial. To report our experience in radioiodine therapy of paediatric GD patients and analyse its effectiveness and safety. We retrospectively studied our paediatric population (de Pediatría. Published by Elsevier Espana. All rights reserved.

  11. On-line monitoring system for I-131 manufacturing labs

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  12. Methodology for management of therapeutic dose of I-131

    Basteris M, J.; Gomez D, R.

    2007-01-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment previously described with a therapeutic dose bigger than ablative of Iodine 131, as well as the use of citric fruits to stimulate the salivation, the administration of liquid post-dose is included to accelerate the gastric emptying avoiding the secondary effects as the vomit. (Author)

  13. Methodology to administer therapeutic dose of I-131

    Basteris M, J.; Gomez D, R.

    2007-01-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment of the thyroid cancer with Iodine-131, as well as the use of citric fruits to stimulate the salivation, the post-dose administration of liquids to accelerate the gastric emptying avoiding the secondary effects as the vomit is included. (Author)

  14. Efficacy of different I-131 doses for thyroid remnant ablation

    Nguyen, X.C.; Thiep, T.V.; Hung, N.C.

    2007-01-01

    Full text: Radioactive iodine 131 I has been widely used as a treatment modality of differentiated thyroid carcinoma. The need for high dose radioiodine ablation of thyroid remnant is still in question. The aim of this prospective study was to assess the efficacy of 131 I different single and fractionated doses in ablation of post-operative thyroid remnant. Patients and methods: One hundred-twelve patients were included in this study. Sixty-one patients with TSH≥30 μU/ml were treated 30 mCi in group 1 (36 patients) or 100 mCi in group 2 (25 patients). Fifty one patients with TSH 131 I high dose of 100 mCi and no severe adverse effect in the other groups. Conclusion: Single high dose (100 mCi) may be more efficient than single low dose (30 mCi) for post-operative remnant ablation with serum TSH≥30 μU/ml and the efficacy of low fractionated doses (30+30 mCi) was comparable with high-fractionated dose (30+100 mCi) for post-operative remnant ablation with low serum TSH in differentiated thyroid carcinoma. (author)

  15. Preparation of Labelled I131 Rose-Bengal

    Mayani, Mbutyabo; Chabouri, Galaal.

    1978-01-01

    Rose bengal purified on a Sephadex G-25 column has been labelled with iodine-131. The exchange reaction has been undertaken in an ether - alcohol medium. The influence of different factors (iodine concentration, Psup(h), purity and chemical form of the substratum, reaction rate) on the labelling yield has been studied. Radiochemical yield of 90% have been obtained in some conditions instead of the normal 80% reported in the literature

  16. The non-conventional therapeutical indications of I 131

    Delisle, M.J.; Schvartz, C.; Maes, B.; Vaudrey, C.; Pochart, J.M.

    1997-01-01

    In our therapeutic activity the non-conventional indications represent 5-10% relative to the indisputable indications which the hyperthyroidism in the second half of the life and the differential thyroid cancers are. In this paper our experience since 1966 is revised and confronted with the data of international literature. In the last almost 40 years we have treated 178 hyperthyroidism of which 17 were youngsters between 16 and 20 years old, 17 multi-nodular euthyroid goiters (MEG), 85 advanced cardiopathies and 8 Cordarone cardiopathies. The indications are precise: relapses after ATS or surgery in young subjects, counter-indications or surgery refusal for the MEGs and cardiologic indications. The long term surveillance was managed by an adequate code. Immediate morbidity is null. The efficiency is high in the hyperthyroidism treatment. The hypothyroidism is diagnosed and early treated. The reduction of the MEG mass is significant. An objective amelioration of the heart state was obtained (23%). The evaluation of the preventive effect of induced hyperthyroidism by Cordarone is underway. In conclusion, the enlargement of indications concerns mainly the hyperthyroidism in young subjects. In order to avoid carcinogenic risks we excluded the children under 16 years, excepting for special situations. This extension to the procreation age imposes a rigorous application of contraception and radiation protection instructions and needs a prolonged evaluation of results

  17. Micronucleus induction as a measure of I-131 exposure

    Kasuba, V; Horvat, D [Inst. for Medical Recearch and Occupational Health, Zagreb (Croatia). Laboratory for Mutagenesis; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine; Vlatkovic, M [Clinical Hospital Centre, Zagreb (Croatia). Dept. of Nuclear Medicine and Radiation Protection

    1994-10-01

    The change of cell numbers in the peripheral blood following irradiation has been studied for many years, particularly in patients undergoing radiotherapy. Recently, attention is directed towards the use of cytogenetic-mutagenetic methods to estimate the biological effects of received radiation dose. The aim of our study was to identify the difference in number and distribution of micronucleus, depending of applied therapeutic dose of iodine-131. According to their diagnosis, six patients have received iodine-131 in range from 80 to 140 mCi, while in the other group of patients the dose values varied from 7 to 32 mCi. On in vitro peripheral blood lymphocyte cultures micronucleus test was applied. Micronucleus analyses were carried out before the treatment, 24, 48 and 96 hours after the oral application of radiopharmaceutical. The number of micronucleus is showing increase, depending on applied radioactivity of iodine-131 and duration of exposition. The clear dose response relationship was never found. These results illustrate the problem associated with the inhomogeneous distribution of dose which results from the concentration of incorporated radionuclide into thyroid or other tissues. (author).

  18. I-131 metaiodobenzylguanidine: diagnostic use in neuroblastoma patients in relapse

    Heyman, S.; Evans, A.E.; D'Angio, G.J.

    1988-01-01

    Metaiodobenzylguanidine (MIBG) has been used for the detection and treatment of neuroectodermal tumors, including neuroblastoma. We report our experience with 131 I-MIBG used diagnostically in neuroblastoma patients with relapse. Thirty-eight studies were performed in 26 patients. There were 24 children (range 3 months-14 years) and two adults. While the study was found to be both sensitive and specific for the presence of disease, there are instances of discordance. False-negative studies were found with a markedly anaplastic tumor and with two mature ganglioneuromas. A bone lesion was negative with 131 I-MIBG, but positive on bone scan. A biopsy confirmed the presence of neuroblastoma. Caution should be exercised when scanning pretreated patients, and perhaps with newly diagnosed patients as well

  19. The non-conventional therapeutical indications of I 131; Les indications therapeutiques non conventionnelles de l`I 131

    Delisle, M.J.; Schvartz, C.; Maes, B.; Vaudrey, C.; Pochart, J.M. [I.J.G. BP 171, 51056 Reims (France)

    1997-12-31

    In our therapeutic activity the non-conventional indications represent 5-10% relative to the indisputable indications which the hyperthyroidism in the second half of the life and the differential thyroid cancers are. In this paper our experience since 1966 is revised and confronted with the data of international literature. In the last almost 40 years we have treated 178 hyperthyroidism of which 17 were youngsters between 16 and 20 years old, 17 multi-nodular euthyroid goiters (MEG), 85 advanced cardiopathies and 8 Cordarone cardiopathies. The indications are precise: relapses after ATS or surgery in young subjects, counter-indications or surgery refusal for the MEGs and cardiologic indications. The long term surveillance was managed by an adequate code. Immediate morbidity is null. The efficiency is high in the hyperthyroidism treatment. The hypothyroidism is diagnosed and early treated. The reduction of the MEG mass is significant. An objective amelioration of the heart state was obtained (23%). The evaluation of the preventive effect of induced hyperthyroidism by Cordarone is underway. In conclusion, the enlargement of indications concerns mainly the hyperthyroidism in young subjects. In order to avoid carcinogenic risks we excluded the children under 16 years, excepting for special situations. This extension to the procreation age imposes a rigorous application of contraception and radiation protection instructions and needs a prolonged evaluation of results

  20. Methodology for management of therapeutic dose of I-131; Metodologia para administrar dosis terapeutica de I-131

    Basteris M, J.; Gomez D, R. [Universidad Autonoma de Yucatan, Facultad de Medicina, Merida, Yucatan (Mexico)

    2007-07-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment previously described with a therapeutic dose bigger than ablative of Iodine 131, as well as the use of citric fruits to stimulate the salivation, the administration of liquid post-dose is included to accelerate the gastric emptying avoiding the secondary effects as the vomit. (Author)

  1. Scientific production of the Radioprotection and Dosimetry Institute (IRD): preliminary bibliometric evaluation of the journal articles; Producao cientifica do Instituto de Radioprotecao e Dosimetria (IRD): avaliacao bibliometrica preliminar dos artigos de periodicos

    Gusmao Pedrini, A de [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia; [Universidade Santa Ursula, Rio de Janeiro, RJ (Brazil). Centro de Ciencias Biologicas

    1994-12-31

    A total of 114 articles (1974-1991, this last year the most productive) in 28 periodicals were published. The periodical core production is made up of: Health Physics, Radiation Protection Dosimetry, Radioprotecao e Dosimetria, Radiologia Brasileira. 53% were written in cooperation with 33 institutions. The 155 authors and 376 authorship were mainly in collective and triple-authorship articles. Mean productivity/author was 2.8 articles which is lower than that of Price. The most productivity author produced 14 articles + 19 co-authors in 7 periodicals on environmental radiation protection while 88 authors produced 1 article. The productive elite (12 authors) accounted for 72 articles, 26% above the average according to Lotka, with 111 out of a total of 376 authorships in 20 periodicals. The elite forms an inter departmental communication network with authors who write about environmental, occupational and individual radiation protection. (author). 17 refs, 1 tab.

  2. Transtornos invasivos do desenvolvimento não-autísticos: síndrome de Rett, transtorno desintegrativo da infância e transtornos invasivos do desenvolvimento sem outra especificação Non-autistic pervasive developmental disorders: Rett syndrome, disintegrative disorder and pervasive developmental disorder not otherwise specified

    Marcos T Mercadante

    2006-05-01

    Full Text Available A categoria "transtorno invasivos do desenvolvimento" inclui o autismo, a síndrome de Asperger, a síndrome de Rett, o transtorno desintegrativo da infância e uma categoria residual denominada transtornos invasivos do desenvolvimento sem outra especificação. Nesta revisão, a síndrome de Rett e o transtorno desintegrativo da infância, que são categorias bem definidas, serão discutidas, assim como as categorias não tão bem definidas que foram incluídas no grupo transtornos invasivos do desenvolvimento sem outra especificação. Diferentes propostas de categorização têm sido feitas, algumas baseadas em abordagem fenomenológica descritiva, outras baseadas em outras perspectivas teóricas, tais como a neuropsicologia. As propostas atuais são apresentadas e discutidas, seguidas por avaliações críticas sobre as vantagens e desvantagens desses conceitos.The category "Pervasive Developmental Disorders" includes autistic disorder, Asperger's syndrome, Rett's syndrome, childhood disintegrative disorder, and a residual category, named pervasive developmental disorder not otherwise specified. In this review, Rett's syndrome and childhood disintegrative disorder, which are well-defined categories, will be discussed, as well as the not well defined categories that have been included in the Pervasive Developmental Disorder Not Otherwise Specified group. Different proposals of categorization have been created, some of which based on descriptive phenomenological approach, and others based upon other theoretical perspectives, such as neuropsychology. Current proposals are presented and discussed, followed by critical appraisals on the clinical advantages and disadvantages of these concepts.

  3. Neutron dosimetry; Dosimetria de neutrons

    Fratin, Luciano

    1993-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is sufficiently sensitive to thermal and intermediate neutrons but fast neutron monitoring ar radiological protection level would require an integration period of over a month. The proposed dosimetric procedure is based on the conjugated use of the developed personal dosemeter and the Bonner multisphere spectrometer. (author) 58 refs., 31 figs., 12 tabs.

  4. Neutron dosimetry; Dosimetria de neutrons

    Fratin, Luciano

    1994-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is sufficiently sensitive to thermal and intermediate neutrons but fast neutron monitoring ar radiological protection level would require an integration period of over a month. The proposed dosimetric procedure is based on the conjugated use of the developed personal dosemeter and the Bonner multisphere spectrometer. (author) 58 refs., 31 figs., 12 tabs.

  5. Thyroid dose of I-131 absorbed by the internal organs of a pregnant woman; Dosis tiroidea de I-131 absorbida por los organos internos de una embarazada

    Arcos P, A; Manzanares A, E; Vega C, H R; Leon, C.L. de . [Cuerpo Academico de Radiobiologia de la Universidad Autonoma de Zacatecas (Mexico)

    2007-07-01

    The use of nuclear techniques, for diagnosis or treatment, generates stress in the patient and its relatives. During the pregnancy some sufferings related with the thyroid gland can be presented. If the patient is pregnant, OEP or NOEP, the stress comes from the fear to that the product can it turns affected. The dose is calculated that the Iodine 131, captured by the thyroid of a woman with three months of pregnancy, it deposits in the brain, stomach, heart, kidneys, liver, lungs, ovaries, pancreas, thymus, spleen and in the uterus. The thymus is the organ that receives the biggest dose. (Author)

  6. Aplicaciones clínicas del radioyodo 131 (I131 en las enfermedades del tiroides Clinical applications of radioiodine 131 (I131 in the thyroid diseases

    Levi González Rivero

    2012-12-01

    Full Text Available El radioyodo 131 es un isótopo radioactivo que se emplea exitosamente en el diagnóstico y tratamiento de las enfermedades benignas y malignas del tiroides. Su propiedad de integrarse selectivamente al metabolismo del tiroides y emitir una señal, le permite describir el funcionamiento glandular mediante estudios de captación, y delimitar la morfología y localización de los tejidos que capten yodo, a través de la gammagrafía. Es además una radioterapia sencilla, segura y coste-efectiva, usada como primera línea terapéutica en el control del hipertiroidismo, cuya dosis y momento de aplicación debería individualizarse según la etiología y la clínica de cada paciente. El radioyodo 131 ofrece una alternativa eficaz para reducir el tamaño del bocio no tóxico; además, respalda el tratamiento quirúrgico del carcinoma diferenciado del tiroides, y destruye a dosis ablativa los restos tisulares y las lesiones metastásicas que puede identificar durante el seguimiento gammagráfico. El empleo de radioyodo 131 está sujeto al cumplimiento de regulaciones de protección contra la radioactividad.Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of gammagraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses the tissular remains and the metastatic lesions that can be detected during the gammagraphic follow-up. Radioiodine 131 depends on the fulfillment of safety regulations against radioactivity.

  7. Individual monitoring of external exposure in terms of personal dose equivalent, H{sub p}(d); Dosimetria personale esterna in termini di equivalente di dose personale, H{sub p}(d). Atti. Giornata di studio, Bologna, 28 febbraio 2001

    Fantuzzi, E. [ENEA, Div. Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche Ezio Clementel, Bologna (Italy)

    2001-07-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H{sub p}(d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H{sub p}(d) e H{sup *}(d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H{sub p}(d), the conversion coefficients, H{sub p}(d)/K{sub a} e H{sub p}(d)/{sub ,} obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H{sub p}(d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported. [Italian] L'Istituto per la Radioprotezione dell'ENEA di Bologna ha organizzato una giornata di studio Dosimetria personale esterna in termini di equivalente di dose personale, H{sub p}(d). Lo scopo della giornata e' stato quello di discutere le novita' e le modifiche da apportare alle pratiche di monitoraggio dell'esposizione esterna alle radiazioni ionizzanti, a seguito dell'entrata in vigore

  8. Thyroid dose of I-131 absorbed by the internal organs of a pregnant woman

    Arcos P, A.; Manzanares A, E.; Vega C, H.R.; Leon, C.L. de

    2007-01-01

    The use of nuclear techniques, for diagnosis or treatment, generates stress in the patient and its relatives. During the pregnancy some sufferings related with the thyroid gland can be presented. If the patient is pregnant, OEP or NOEP, the stress comes from the fear to that the product can it turns affected. The dose is calculated that the Iodine 131, captured by the thyroid of a woman with three months of pregnancy, it deposits in the brain, stomach, heart, kidneys, liver, lungs, ovaries, pancreas, thymus, spleen and in the uterus. The thymus is the organ that receives the biggest dose. (Author)

  9. Feasibility study for production of I-131 radioisotope using MNSR research reactor

    Elom Achoribo, A.S., E-mail: achoribo@yahoo.fr [Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, P.O. Box LG80, Legon Accra (Ghana); Akaho, Edward H.K. [Ghana Atomic Energy Commission, P.O. Box LG80, Legon Accra (Ghana); Nyarko, Benjamin J.B.; Osae Shiloh, K.D. [National Nuclear Research Institute, Ghana Atomic Energy Commission, P.O. Box LG80, Legon Accra (Ghana); Odame Duodu, Godfred [Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, P.O. Box LG80, Legon Accra (Ghana); Gibrilla, Abass [National Nuclear Research Institute, Ghana Atomic Energy Commission, P.O. Box LG80, Legon Accra (Ghana)

    2012-01-15

    A feasibility study for {sup 131}I production using a Low Power Research Reactor was conducted to predict the yield of {sup 131}I by cyclic activation technique. A maximum activity of 5.1 GBq was achieved through simulation using FORTRAN 90, for an irradiation of 6 h. But experimentally only 4 h irradiation could be done, which resulted in an activity of 4.0 Multiplication-Sign 10{sup 5} Bq. The discrepancy in the activities was due to the fact that beta decays released during the process could not be considered. - Highlights: Black-Right-Pointing-Pointer For a high irradiation time, the neutron flux will give high activity. Black-Right-Pointing-Pointer For maximum number of irradiation that can be done a maximum activity could be obtained. Black-Right-Pointing-Pointer An idea on how to maximize the activity (recommendation).

  10. Technical solution for radioactive waste management resulting from the I-131 therapy

    Jerez V, P.; Lopez F, Y.; Quevedo G, J.; Betancourt H, L.

    1996-01-01

    The paper discusses a system designed for the collection and storage of biological wastes arising from the therapy with l-131. This system is based on the use of either retention or septic tanks, in which the waste is stored or delayed until the activity decays to acceptable levels, in order to comply with authorized limits established by the Regulatory Authority for discharge to environment. A method for estimating waste activity concentration as a function of the number of patients, the activity delivered to each one of them, as well as other parameter related to the system design are discussed. The general requirements to be met by the system are also included. (authors). 4 refs., 4 figs

  11. THE MANAGEMENT OF THYROID CARCINOMA--THE ROLE OF RADIO-IODINE (I-131)

    Workman, James B.

    1963-06-15

    Experience from the management of 156 patients with proven thyroid cancer, followed from 1 to 11 years, is reported. Although no sweeping conclusions can be drawn, it appears that radioiodine continues to have a place in the overall management of most cases of this malignant disease. (auth)

  12. Dosimetric comparison fixed-individualized activity in the treatment of serious disease with I -131

    Melgar Perez, J.; Orellana Salas, A.; Santaella, Y.; Arrocha Acevedo, J. F.

    2013-01-01

    The iodine-131 therapy has become the treatment with radiopharmaceuticals more frequent in our country, as well as the largest source of exposure to ionizing radiation for members who surround the patient. The aim of this article is to analyse the recommendations of radiological protection which are delivered to the patient receiving radiation discharge, in terms of the duration of the same time, taking into account the radiopharmaceutical dose, the time of entry, the dose rate measured at one meter and the family environment among others. (Author)

  13. External dose measurements for patients receiving therapeutic I-131 for thyroid cancer

    Molfetas, M.; Kottou, S.

    2002-01-01

    Iodine-131 is a well established and effective treatment, supplementing surgery, in differentiated thyroid carcinoma. Iodine-131 except from its β-emission, that generates a cell-killing effect in a small area, has also a γ-emission irradiating distant tissues and even people who are close enough with the treated patient. The International Commission on Radiation Protection, ICRP has estimated the probability of a radiation-induced fatal cancer for the whole population at 5.0 % per sievert for low doses and at low dose rates and at 1.3 % for serious genetic diseases. For elderly people the probability seems to be 3 to 10 times lower, whereas for children up to the age of 10 years, 2-3 times higher. These findings led the ICRP to recommend new dose limits, lower than the previous ones. The European Union has endorsed the ICRP recommendations and the Council issued two directives, with which the Greek legislation complied recently. The current annual public dose limit is 1 mSv, while in the new Greek legislation the concept of dose constrains (0.5 m Sv in Greece) has also been proposed as a goal to reach whenever possible

  14. Fixed dose of I-131 therapy for the treatment of Graves' hyperthyroidism

    Li Lin; Lee, K.

    2004-01-01

    Objectives: To evaluate short-term (6 month) efficacy of fixed-dose (555 MBq, 15 mCi) approach in the treatment of Graves' hyperthyroidism and analyze the relationship between clinical outcome (hyperthyroidism, hypothyroidism, and euthyroidism) and variances (patient age, thyroid weight, absorbed activity per gram of thyroid tissue, and radioactive iodine uptake value). Methods: 38 patients of Graves' hyperthyroidism were treated with 555MBq of radioactive iodine (in the form of capsule). Follow-up was done 3 and 6 months post therapy and the following clinical outcome was monitored: persistent hyperthyroidism, hypothyroidism, and euthyroidism. Statistical analysis was performed with SPSS software (version 11.5). P<0.05 was taken as indicating a statistically significant effect. Results: Of the 38 subjects, 14 (36.8%) were identified as euthyroidism, 18 (47.4%) hypothyroidism, and 6 (15.8%) hyperthyroidism. Cure rate (euthyroidism+hypothyroidism) was 84.2%. Statistical analysis revealed that there is a statistically significant difference of absorbed activity per gram of thyroid tissue and thyroid weight (F=17.639, P=0.000; F=28.453, P=0.000), but there is no statistically significant difference in terms of patient age and RAIU (F=1.375, P-0.266; F=2.453, P=0.101) among euthyroidism, hypothyroidism, and hyperthyroidism patients. Conclusion: We concluded that fixed-dose approach is very effective in the quickly restoration of thyroid function. There is a statistically significant difference of absorbed activity per gram of thyroid tissue and thyroid weight, but there is no statistically significant difference in terms of patient age and RAIU among euthyroidism, hypothyroidism, and hyperthyroidism patients. (authors)

  15. Quantitative detection of I-131 at the inlet and outlet of the Giessen municipality sewage works

    Leib, J.; Crecelius, R.; Pfeiff, H.; Faengewisch, G.L.

    1985-01-01

    During the sampling time, the mean quantities of the radioactive iodine delivered to the sewage works were measured to be 66 p.c. at the inlet and 28 p.c. at the outlet. Error sources of the procedure adopted for the study are assessment only of the overall inflow to the sewage treatment plant during sampling time, and lacking exactness of values for the detention period of the radioactive iodine in the sewage plant. Dispersion calculations made in addition to water examinations showed that the mean radiation dose as a result of the iodine discharges is far below the limits set by the Radiation Protection Ordinance. (orig./PW) [de

  16. Study of ablation efficiency of 3600 MBq of I-131 in the treatment of thyroid carcinoma

    Takavar, A.; Eftekhari, M.; Fard-Esfahani, A.; Beiki, D.

    2005-01-01

    Full text: The basic question of threshold for the ablation of thyroid remnant after surgery remains unanswered. However, radioiodine therapy is still being used as a standard method of treatment. In present investigation treatment responses of 100 patients with thyroid cancer treated with 3600 MBq of 131 I is studied. Response to treatment of 100 patients (33 males and 67 females) was evaluated by serum TSH, Tg levels and areas of thyroid remnant as measured by whole body scan with 131 I performed 6 months after therapy. Treatment response was evident by decreased or lack of 131 I uptake in the thyroid bed and Tg 5 ng/ml. Remnant area was decreased about 74.5% in females and 75.5% in males. No significant difference between sex groups was observed. Because of radiation protection concerns and socioeconomic reasons, lower ablations doses of 131 I ( 1110 MBq) might be as effective, and should be evaluated. (author)

  17. Exhalation of I-131 after radioiodine therapy: time dependence and chemical form

    Schomaecker, K.; Fischer, T.; Eschner, W.; Gaidouk, M.I.; Schicha, H.

    2001-01-01

    Aim: The change of both amount and chemical forms of radioiodine exhaled in the air of rooms with patients on the therapy ward should be investigated depending on radioactivity applied, time after application, and kind of thyroid disease. Methods: The air of ward-rooms of 62 patients with thyroid carcinoma, Graves' Disease, and autonomy which received different therapy doses, was investigated with an portable constant air flow sampler. Different chemical iodine species (organic, elemental, aerosol bound) were collected during 8 hr in various filters until 3 days after application of the radioiodine capsule, according to their chemical form. The radioactivity in the filters was measured with a well counter on defined time points after application. Results: The radioactivity exhaled was between 0,008 and 0,03% related to activity of radioiodine applied. The percentage of radioiodine exhaled related to the activity applied, differed significantly depending on disease and changed as follows: Grave's disease > autonomy > carcinoma. The exhalation of radioiodine became stronger with increasing applied activities and showed an exponential decrease with time. The most part of radioiodine was present in organic bound form. This organic portion decreased with time in favour of the other iodine species. Conclusion: The degree of accumulation of radioiodine orally applied within thyroid seems to be in direct proportion to the extend of its exhalation. Further measurements directly in the breathing air of RIT-patients are necessary, in order to clarify the relationship between degree of thyroid uptake and quantity as well as chemical form of radioiodine exhaled. (orig.) [de

  18. Tests of some methods to remove I-131 from contaminated tap water

    Tagami, Keiko; Uchida, Shigeo

    2011-01-01

    Following the Fukushima Daiichi Nuclear Power Plant accident, iodine-131 concentrations in tap water higher than 100 Bq L"-"1 were reported by several local governments in the Kanto Plain in March 2011. To remove iodine-131 from tap water, five methods were tested in this study, that is, (1) boiling, (2) adding charcoals from oak or bamboo, (3) activated charcoals, (4) water purifiers, and (5) reverse osmosis (RO) treatments. Boiling was shown to be not effective in removing iodine-131 from tap water; indeed even higher concentrations may result from the liquid-volume reduction accompanying this process. Adding charcoals and activated charcoal treatment could not remove iodine-131, because no reduction of iodine-131 was observed in tap water samples after these treatments. Only limited effect was found with water purifiers with first several portions; no effect was expected with further water treatment. On the other hand, the RO showed high iodine-131 removal percentage of more than 95%, although the method needs about 5-10 L water to obtain 1 L of RO treated water. (author)

  19. Nose swabs and urinalysis as indicators of exposure to I-131

    Barrall, R. C.

    1963-06-15

    During a maintenance operation on the Aromour Research Reactor, a heat lamp, which was drying a valve, caused a small quantity of I/sup 131/ become airborne. A continuous air monitor sampling in the area gave the alarm and the area ntified by the use of a 256 channel analyzer. Nose swabs of the personnel involved were taken and 24 hour urine samples were obtained. A single channel analyzer was set up, calibrated for I/sup 131/ and thyroid counts were started several hours after the incident. The thyroid count rose during the first 24 hour period and then declined closely following the 8 day half life of I/sup 131/. The urine Samples were analyzed by two different gamma counting techniques. Portions of the 24 hour urine sample were also sent to a commercial urinalysis service and analysis for I/sup 131/specifically requested. The results of the commercial service in this instance appeared to be poor. Nose swabs taken immediately after the incident were analyzed using a NaI well crystal. The average value of the ratio mu c on nose swabs to mu c in thyroid was found to be 2.6 x 1-/sup -1/ with all values within a factor of 6. The average value of the ratio mu c in 24 hour urine sample to mu c in thyroid was 5.7 with all values within a factor of 2. It would appear that at short times after a suspected exposure to I/sup 131/ nose swabs and urine samples are both useful in making a rapid assessment of exposure. The data presented are based on 10 subjects. (auth)

  20. Differences in the dry deposition of gaseous elemental I-131 to several leafy vegetable species

    Shinonaga, T.; Heuberger, H.; Tschiersch, J.

    2004-01-01

    The height of the dry deposition of gaseous elemental 131 I to leafy vegetable is quite uncertain because of the different habit, surface texture and leaf uptake of the different plant species. There is no comparative data on the deposition to various species, but leafy vegetables are taken as reference plants for the estimation of the height of contamination of vegetable foods after a nuclear accident. Therefore new chamber experiments were performed to determine under homogeneous and controlled conditions the dry deposition of gaseous elemental 131 I on mature leafy vegetable. The simultaneous exposition of endive, head lettuce, red oak leaf lettuce and spinach (spring leafy vegetable) rsp. curly kale, white cabbage and spinach (summer leafy vegetable) was arranged. The sample collective of each species was such large that for the expected variation of the results a statistically firm analysis was possible. Significant differences were observed for the 131 I deposition on spring vegetable: the deposition on spinach was roughly 3 times that on leaf lettuce, 4 times that on endive and 9 times that on head lettuce. All summer vegetables showed differences in deposition. For Iodine, the deposition on spinach was roughly 3 times (6 times) that on curly kale and 35 times (100 times) that on white cabbage in the 2 experiments. Washing by deionised water could reduce the contamination only by about 10% for 131 I. (author)

  1. 77 FR 71432 - Agency Information Collection Activities: Application for Travel Document, Form Number I-131...

    2012-11-30

    ... guidance regarding recipients' of Deferred Action under Childhood Arrivals (DACA) ability to request... deferred action under childhood arrivals (DACA) may now request an advance parole documents based on...; Revision of a Currently Approved Collection ACTION: 30-Day Notice. SUMMARY: The Department of Homeland...

  2. Exposure rate measurements and radiation control in post therapy with I131

    Vazquez A, M.; Castillo D, C.; Flores U, H.; Cespedes C, L.; Morgan N, C.; Sifuentes D, Y.; Marin R, K.

    2015-10-01

    During hyperthyroidism treatment, 131 I activities from 111 MBq up to 296 MBq are used. In the aim to determine if the 131 I uptake by the patient is a radiological risk to family members and public around the patient exposure rate measurements were carried out, using a limit 1.8 m R/h. Measurements were carried out in the Nuclear Medicine department of Almenara hospital in Lima, Peru. The exposure rate was measured to 0.3, 0.6, and 1.0 m from the patient from 0 to 11 days after post-administrated dose (Pda). In this study measurements were carried out in 21 hyperthyroid patients. Measurements to 1 meter, along 2-4 (16/16), 5-7 (15/15), and 8-11 (14/14) days after Pda, indicate the dose rate around 100% of patients is ≤ 1.8 m R /h. Measurements to 0.6 meters along 2-4 (16/16), 5 -7 (15/15), and 8-11 (14/14) days after Pda, indicate that the dose rate around 44% (7/16), 93% (14/15), and 100% (14/14) of patients is ≤ 1.8 m R h. On the other hand, dose rate measurements to 0.3 meters, along 2-4 (16/16), 5-7 (15/15), and 8 -11 (14/14) days after Pda, indicate that de dose rate is 13% (2/16), 6% (1/15), and 43% (6/14) of patients is ≤ 1.8 m R/h. Measured exposure rates are alike to values reported in the literature, and were used to define radiation control recommendations. (Author)

  3. Internal dosimetry for the radiological protection of the patient in the therapy with I-131

    Deluca, G.M.; Rojo, A.M.

    2006-01-01

    In the patients with differentiated thyroid cancer (CADIT) subjected to therapy with radiopharmaceuticals should be considered the possible risk of sharp depression of the bone marrow like consequence of the intolerance to the quantity of administered activity. The manifestation of the myelotoxicity can limit in a substantial way the future treatments and to deteriorate the predict of resolution of the illness. In this work it shows the physical-mathematical mark of a methodology for the estimated absorbed dose in bone marrow based in the MIRD scheme whose objective is to protect the one patient of the noxious and undesirable effects of the internal radiotherapy in organs that are not target of the same one. The formalism incorporates specific information of the patient and also peculiar characteristics of the internal therapy in patient with CADIT. The considerations are the following ones: (1) the main organ to protect is the bone marrow: (2) the accumulated activity, in bone marrow, it is obtained starting from measurements in blood: (3) the used isotope almost exclusively in this type of therapies is the 131 I; (4) it is used as radiopharmaceutical at the 131 INa that it is characterized to be a simple, inorganic and small molecule: (5) the statistical incidence of the CADIT is bigger in women than in men. It is explained for that it was selected the formalism that is presented, the principles on which it is sustained which are their reaches and their limitations. They are also presented future innovations that can be implemented to effects of improving the estimates. The work is framed inside the thematic of the medical applications of open radioactive sources and it constitutes a contribution to the invigoration of the internal therapy with radiopharmaceuticals. This is due to that the methodology of dose estimation presented supplements with a theoretical biophysics base the protocols of empiric prescription broadly used in this practice. For these reasons, the dosimetric information obtained, adjusted to each concrete case, it contributes to improve the radiological protection of the patient. (Author)

  4. Use of I-131- CRTX for targeting malignant adenocarcinoma in mice: biodistribution and radiation dosimetry

    Santos, Raquel Gouvea dos; Soares, Marcella Araugio; Andrade, Henrique Martins de; Santos, Marcos Antonio da Cunha

    2008-01-01

    Snake venoms molecules have been shown to play a role not only in the survival and proliferation of tumour cells but also in the processes of tumour cell adhesion, migration and angiogenesis. We have shown that 125 I-Crtx, a radiolabeled version of a protein derived from Crotalus durissus terrificus snake venom (Cdt), specifically binds to tumor and triggers apoptotic death. This study reports the biokinetic profile of 99m Tc-Cdt and 125/131 I-Crtx in Swiss mice bearing Ehrlich solid tumor and MIRD formulation was applied to calculate the absorbed radiation doses for various organs and tumor site. Biokinetic evaluations were performed up to 24 h after intravenous (i.v) or intratumor (i.tu.) injection of 99m Tc-Cdt or 125/131 I-Crtx. Time-activity curves were generated for the main organs by fitting the organ specific mass mean counts. The radiation dose from 131 I-Crtx was calculated based on non penetrating radiation in the mouse model. Biokinetics data from 99m Tc-Cdt after i.v. injection in mice tumor model showed rapid blood clearance (T 1/2 = 36.1 ± 2.4 min.), slow tumor clearance (T 1/2 : 108.3 ± 19.5 min.) and indicated the kidneys as the main excretion pathway. Interaction studies in vitro demonstrated that 125 I-Crtx recognize specific sites on Erlich tumor cell membrane. Upon intravenous and intratumor administration of 131 I-Crtx in mice bearing Erlich tumor, it was observed high uptake in tumor site in vivo (Ã =72kBq x h/g) resulting in a high absorbed dose radiation to tumor site. Distributions of 125/131 I-Crtx i.v. were only significant in tumor, stomach, liver and kidneys, reflecting non-specific uptake of Crtx in normal excretion tissues in vivo. Intratumoral administration reduced significantly the radiation dose to the kidneys (42-fold lower) and increased the uptake by the tumor site (128- fold higher). 131 I control was run in a parallel experiment and showed no significant tumor uptake. In conclusion, 131 I-Crtx had a high concentration in tumor and low concentration in normal organs in mice bearing Erlich tumor. Tumor-to-normal tissue radiation dose ratio, for intratumor injected 131 I-Crtx, were more than 60-fold higher depending on the organ. Our results indicate that Cdt components may provide interesting templates for development of a tool for targeted radiotherapy against adenocarcinoma. (author)

  5. Clinical applications of radioiodine 131 (I131) in the thyroid diseases

    Gonzalez Rivero, Levi; Turcios Trista, Silvia Elena; Velasco Mirabal, Milagros

    2012-01-01

    Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of scintigraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses the tissular remains and the metastatic lesions that can be detected during the gammagraphic follow-up. Radioiodine 131 depends on the fulfillment of safety regulations against radioactivity

  6. Clinical applications of radioiodine 131 (I131) in the thyroid diseases

    Gonzalez, Rivero Levi; Turcios Trista, Silvia Elena; Velasco Mirabal, Milagros

    2012-01-01

    Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of gammagraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses the tissular remains and the metastatic lesions that can be detected during the gammagraphic follow-up. Radioiodine 131 depends on the fulfillment of safety regulations against radioactivity

  7. An experiment to use medical I-131 as tracer in a city sewer system

    Ulbrich, Susanne; Fischer, Helmut W. [University of Bremen, Institute of Environmental Physics, Otto-Hahn-Allee 1, D-28359 Bremen (Germany)

    2014-07-01

    City sewer systems have to reliably carry residential and industrial wastewater to treatment plants, often mixed with rainwater. Transport in the sewer system is regularly modelled in order to predict sewerage levels, transport velocities and volume discharges. Radioisotopes would be interesting tracers, as they can be detected quickly and without the need of applying wet chemistry. Medical isotopes are released in large quantities (many MBq) by excretion from patients either at the location of administration or from elsewhere, most probably the patient's home. Depending on diagnostic or treatment modality, isotopes of different physical characteristics are used, often bound to compounds of specific metabolic behaviour. Routine environmental surveillance regularly detects the most common diagnostic ({sup 99m}Tc) and therapeutic ({sup 131}I) isotopes in city wastewater samples. Except for {sup 131}I in the case of a nuclear emergency, no contributions from sources other than medical are expected. Medical isotopes therefore might be used for tracing purposes, provided individual inputs can be identified and separated. A field experiment has been designed involving {sup 131}I releases from a single patient who had undergone radioiodine thyroid ablation therapy. This modality is applied after thyroid cancer surgery in order to destroy residual thyroid tissue. Activities up to 5 GBq of {sup 131}I are used which are excreted within few days, as no iodine-retaining thyroid tissue remains. In Germany, about 20,000 of these treatments are performed yearly. For a sewer system of 500,000 inhabitants, about 150 cases would be expected per year, making it quite improbable to have interference between individual patient releases in the same region of the city sewer system. Practically, the radiometric laboratory was informed of the expected release of an (anonymous) patient from the collaborating radiotherapy unit several days in advance, plus the approximate location of the patient's home. Together with the sewage system authority, automated sampling (mostly in 6 h intervals) over one week at four locations between the patient's home quarter and the sewage plant inlet was planned and successfully conducted, delivering a total of 84 samples. Sampling started before the assumed arrival of the patient at his home, to account for 'background' signal due to releases from other patients. The samples were investigated for {sup 131}I by high resolution gamma spectroscopy, with a detection threshold of down to ca. 0.1 Bq/l, depending on the allocated measurement time. Data time series plots show clearly distinguishable peaks in {sup 131}I activity, with peak amplitude decreasing from over 1 kBq/l to below 1 Bq/l with distance from the patient's home quarter (due to dilution) and peak time being retarded (due to transport time). At the two most distant sampling points, the peak appears on a variable background, attributed to {sup 131}I releases of other patients. Modelling with specific sewer system software is still under way, but the data already show that under suitable conditions medical isotopes can successfully be used as sewage tracers. (authors)

  8. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  9. Medical evaluations of ionizing radiation effects during I131 therapy in patients after thyroid carcinoma surgery

    Hermida, J.C.

    1996-01-01

    This study shows the para-clinical studies on a 39 years old patient who was operated on of a thyroid carcinoma and who, under the beirwaltes medical record (in use in our country), received in the post surgical stage, a Iodine-131 dose of about 2960 MBq (80 mCi) for ablation, having been noted subsequently her pregnancy condition. (author). 6 refs

  10. Absorbed dose to the human adrenals from iodomethylnorcholesterol (I-131) NP-59: concise communication

    Carey, J.E.; Thrall, J.H.; Freitas, J.E.; Beierwaltes, W.H.

    1979-01-01

    During the past 2 yrs, adrenal uptake percentage values were measured in more than 40 patients, using an external counting technique. They suggest that the absorbed dose to the adrenals is significantly less than the 150 rads/mCi previously estimated using concentration values from animal adrenals. The measured combined uptake percentage for both adrenals ranged from 0.15% to 0.52% in 21 patients without evidence of adrenal disease, with a mean of 0.33% +- 0.1%; also from 0.22% to 1.5% in 22 patients with Cushing's disease, with a mean uptake of 0.78% +- 0.35%. The absorbed dose to the adrenals was estimated to be 25 rads/mCi for patients without evidence of adrenal disease, and 57 rads/mCi for patients with Cushing's disease. Both values are calculated for the respective mean uptake percentages by using the MIRD formalism

  11. Studies on the radiation burden using I-131 for thyroid therapy

    Krzesniak, J.W.; Chomicki, O.A.

    1980-01-01

    The exposure to personnel from 131 I inhaled from open sources during laboratory procedures and that exhaled by patients treated with 131 I was estimated. The method and the apparatus used to detect airborne 131 I are described. It was found that the ratio of the activity absorbed through the lungs to that permissible for a given category of exposure is not higher than 10%. The kinetics of the 131 I exhaled by patients seems to be complementary to that of 131 I concentration changes in the blood. (H.K.)

  12. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: cmo@cdtn.br

    2009-07-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  13. Use of Br-82 and I-131 radionuclides in studies of goitrogenic effects of exogenous bromide

    Pavelka, Stanislav

    2012-01-01

    Roč. 291, č. 2 (2012), s. 379-383 ISSN 0236-5731 R&D Projects: GA ČR(CZ) GA304/08/0256 Institutional research plan: CEZ:AV0Z50110509 Keywords : bromide * goitrogenic effect * iodine radionuclides * thyroid hormone Subject RIV: ED - Physiology Impact factor: 1.467, year: 2012

  14. I-131 Therapy in patients with hyperthyroidism 11- year follow-up

    Radeva, M.

    2007-01-01

    Full text: Radioiodine therapy is a well-established method for the treatment of patients with various forms of hyperthyroidism and is preferred in many countries as the first line therapy. Traditionally, it has been applied in Bulgaria in low doses, mainly in elderly patients with contraindications for surgery or after long-term antithyroid drug therapy. No systematic follow up of these patients has ever been done in the country. Materials and Methods: 571 subjects aged 34 to 79 years (mean 64, 7), 108 males with mean age of 68.61 years (54 to 76 yrs) and 463 females with mean age of 68.89 years (34 to 84 yrs). Mean disease duration was 73±5 months. The study included 296 patients with toxic nodular goiter, 220 patients with Graves- Basedow disease and Hashitoxicosis and 55 patients with adenoma toxicum. 256 females and 40 males with toxic nodular goiter, 158 females and 62 males with Graves- Basedow disease and Hashitoxicosis, 49 females and 6 males with adenoma toxicum. The disease duration is 48.19 months in females and 22.5 months in males. Methods: 131-iodine scan and uptake before the treatment and on follow-up visits at months 6,12,18 and 24 with a dose of 1.48 MBq 131-I for the both tests, given orally as a water solution. Uptake was measured at hours 2, 4 and 24; thyroid scan -at hour 24, thyroid ultrasound, FNB cytology if suspicious of malignancy, thyroid hormones -TSH (normal range 0.3-4.0 mU/l), FT4 (normal range 8-17 pmol/l) Results: 131-iodine therapy was administered to subjects with 131-I uptake over 25% at hour 24. Doses between 148- 370MBq were given depending on diagnosis and thyroid volume. A single radioiodine dose, mean value 189.07 MBq is applied in 246 (87, 85%) patients, second dose, mean value 183, 5 MBq is required in 30 (10, 72%) and third dose, mean value 148 MBq received 4 (1, 43%) patients. Effect of 131-iodine therapy-the change in radioiodine uptake is a marker for complex assessment of the result of the 131-iodine therapy. In subjects with successful treatment the uptake at the various follow-up intervals drops by 38.0%-62.0%, 57,41% of patients are euthyroid, 12,96% are hypothyroid and 29,63% are hyperthyroid. The hypothyroid status is accepted as effective treatment results. Definitive treatment is determined in 70.37% at 6 month. The second control performed 12 months later presents 67,57% euthyroid patients, 13,5% hypothyroid patients and 18,91% hyperthyroid patients. Definitive treatment is determined in 81.07% at 12 months.The control measurements after 18 months showed 58,33% euthyroid patients, 25,0% hypothyroid patients and 16,67% hyperthyroid patients. Definitive treatment is determined in 83.33% at 18 month and this trend is observed in follow-up tests. Significant reduction in the uptake at observed for all measurements (all p<0,001).The change in estimated thyroid mass in subjects treated for hyperthyroidism with radioiodine was 32-48% and this correlates with moderate to severe thyroid atrophy caused by the applies activity 185-222 MBq. There is a significant reduction in the mean estimated mass at months 6 and 12. Conclusions: 1.131-I therapy is a useful, economical and effective treatment and is more successful therapy than surgery. A euthyroid condition of the patient is required in definitive radioiodine treatment. 2. For the assessment of the treatment effect and or establishment of disease relapse, the follow- up period for 24 months after treatment is required. 3. Hypothyroid status after radioiodine treatment is an indicator for successful treatment. 4. The change in estimated thyroid mass in subjects treated for hyperthyroidism with radioiodine varies 32- 48% and this correlates with moderate to severe thyroid atrophy caused by the given activity 148- 370 MBq. 5. The variety of the radioiodine uptake and the thyroid weight are indicators for assessment of therapy effectiveness. 6. The absorbed radioiodine dose in the thyroid gland is 55-220 Gy. This causes moderate to considerable atrophy with reduced metabolic activity and tissue weight and blocks the gr owth potential which results in decreased thyroid hormone production. (author)

  15. Iodine I-131 With or Without Selumetinib in Treating Patients With Recurrent or Metastatic Thyroid Cancer

    2018-05-15

    Metastatic Thyroid Gland Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma

  16. A Quick Method of Measuring and Analyzing {beta} Emitters in Solution of Very Low-Level Specific Activity; Remarques sur une technique rapide de mesure et d'analyse d'emetteurs {beta} en solution de tres faible activite specifique; Zamechaniya o bystroj tekhnike izmereniya i analize izluchatelej {beta}-chastits v rastvore s ochen' slaboj spetsificheskoj aktivnost'yu; Observaciones sobre un metodo rapido de medicion y analisis de emisores {beta} en soluciones de muy baja actividad especifica

    Le Gallic, Y; Grinberg, B; Thenard, M [Centre d' Etudes Nucleaires de Saclay (France)

    1960-06-15

    vaina de contadores conectados en anticoincidencia con los primeros. 2. Ademas enumeran las posibilidades y campos de utilizacion del metodo que: a) especialmente en el caso de los emisores {beta} blandos, permite medir actividades especificas mucho mas bajas que cuando se utilizan contadores para liquidos; b) permite descubrir las sustancias radiactivas presentes como impurezas en determinados radioelementos (por ejemplo, 2/10 000 de P{sup 32} en S{sup 35}); c) para la mayor parte de los radioelementos permite medir, sin necesidad de proceder a una concentracion previa, actividades especificas de igual orden de magnitud que los limites de tolerancia actualmente admitidos. (author) [Russian] 1. Opisanie mekhanizma izmereniya so slabym fonom prednaznachennog o dlya izmereniya radioaktivnykh produktov v zhidkom sostoyanii, kotoryj sostoit v osnovnom iz dvukh ploskikh schetchikov s odnim oknom i odnogo ploskogo schetchika s dvumya oknami, raspolozhenny kh parallel'no drug k DRUGU i izolirovanny kh vnutri zashchitnoj obolochkoj schetchikov, vstavlen- nykh takim obrazom, chtoby oni ne sovpadali s pervymi. 2. Vozmozhnosti i oblasti ispol'zovaniya metoda: a) ehtot metod pozvolyaet izmerit' gorazdo bolee slabuyu spetsificheskuyu aktivnost', chem ehto vozmozhno s zhidkotnymi schetchikami, v chastnosti s izluchatelyami ne zhestkikh {beta}-chastits; b) ehtot metod pozvolyaet obnaruzhivat' radioaktivnye primesi vnutri radioehlementa (napr. 2/10 OOO R{sup 32} v S{sup 35}); s) ehtot metod pozvolyaet dlya bol'shinstva radioehlemento v izmeryat' bez predvaritel'no j kontsentratsii spetsificheskuyu aktivnost' sootvetstvenno ravnuyu prinyatym v nastoyashchee v nastoyashchee vremya predel'nym dopuskam. (author)

  17. The Why and How of Nuclear Accident Dosimetry; Dosimetrie en cas d'Accident Nucleaire: Raison d'Etre et Modalites; 041e 0411 041e 0421 041d 041e 0412 0414 ; Dosimetria en Casos de Accidente Nuclear: Justificacion y Modalidades

    Vallario, E. J.; Wasson, H. R. [United States Atomic Energy Commission, Washington, DC (United States)

    1965-06-15

    des accidents nucleaires risquent de se produire. Lors de la mise au point d'un tel programme, il convient d'etudier certains parametres fondamentaux, a savoir: a) une methode permettant de trier les membres du personnel victimes d'un accident nucleaire; b) un systeme fixe (dispositif primaire) capable de determiner, avec un degre d'exactitude convenu la dose de premier choc a son emplacement meme; c) la necessite de disposer d''appareils secondaires'; d) la necessite de munir le personnel d'un dispositif donnant des indications sur le spectre et le flux afin de faciliter l'extrapolation de la dose en permettant de passer du dispositif fixe a l'emplacement de la personne exposee. La cellule de detection neutronique du systeme devrait renseigner sur le flux et le spectre, de maniere a obtenir des indications qualitatives appropriees dans l'evaluation de la dose. Les degres d'exactitude devront etre fixes d'apres l'etat actuel des connaissances. D'autre part, la cellule de detection gamma devrait permettre de mesurer ce rayonnement dans les limites des intensites d'interet biologique, soit entre 10 et 10{sup 3}r. Pour qu'un systeme de dosimetrie en cas d'accident soit efficace, le nombre d'appareils doit etre suffisant et leur emplacement bien choisi ; il faut aussi pouvoir les recuperer facilement. Si ces conditions sont remplies, on doit obtenir des donnees satisfaisantes sur toute l'etendue du spectre de fission. (author) [Spanish] La finilidad de un programa eficaz de dosimetria es la evaluacion de la dosis de neutrones y rayos gamma resultante de un accidente nuclear. A este respecto, el autor examina las limitaciones que presenta el dosimetro de pelicula, y trata ademas de la experiencia adquirida con ocasion de determinados accidentes nucleares, experiencia que ha demostrado la necesidad de establecer un programa eficaz de dosimetria en las instalaciones en que no se excluya la posibilidad de que se produzcan accidentes de esta clase. Para establecer un programa

  18. High-Dose Ionizing Radiation Photographic Dosimetry; Mesure, par des Methodes Photogra Phiques, de Doses Elevees de Rayonnements Ionisants; 0424 041e 0422 041e 0413 0420 0414 ; Dosimetria Fotografica de Dosis Elevadas de Radiaciones Ionizantes

    Trousil, J.; Bucina, I. [Institute for Research Production and Application of Radioisotopes Prague, Czechoslovakia (Czech Republic)

    1965-06-15

    ionizantes comprendidas entre 10 mr y 1000 r (para rayos gamma y rayos X de elevada energia). Con arreglo a este metodo, se utilizan dos peliculas con emulsiones diferentes, montadas en el mismo estuche. El metodo se caracteriza esencialmente por el hecho de que permite evaluar dosis comprendidas entre los limites indicados, sin necesidad de saber si se produjo una exposicion a dosis mas elevadas, con un margen de error inferior a {+-}25 en todo el intervalo (limite de seguridad 95%); ademas permite determinar con una precision satisfactoria la energia de las radiaciones a que la pelicula estuvo expuesta. Se examinan los aparatos, peliculas y tratamiento quimicos necesarios para esas mediciones. Se explica el principio de construccion de un densitometro que permite medir el ennegrecimiento de la pelicula con una precision constante en el intervalo comprendido entre D = 0 y D = 6. De este modo es posible aprovechar toda la zona de ennegrecimiento de la pelicula correspondiente a dicho intervalo. Como no se utiliza iotomultiplicador, los riesgos de iluminacion excesiva se reducen al minimo, por lo que el aparato resulta apropiado para mediciones corrientes. Ademas se indican los parametros que han de satisfacer las peliculas dosimetricas para poder detectar dosis elevadas, y se comparan las caracteristicas de las peliculas dosimetricas FOMA y ORWO en lo que respecta a la medicion de dosis elevadas. Con un progreso en la dosimetria de dosis elevadas, cabe mencionar el metodo de revelado retardado que se describe con detalle, con arreglo al cual se anaden al revelador compuestos del tipo nitrobenzimidazol y benzotriazol, en concentracion adecuada. En el caso de emulsiones lentas con elevado contenido de plata, esta tecnica permite medir exposiciones de dosis gamma (rayos X de elevada energia) de hasta 10{sup 3}r, o aun mayores, si no es menester una evaluacion precisa en un intervalo de hasta 100 r. Se describe el efecto retardador de los productos quimicos anadidos al revelador

  19. The Importance of Dosimetry to the Medical Management of Persons Accidentally Exposed to High Levels of Radiation; Le Role de la Dosimetrie Dans les Soins Medicaux a Donner aux Personnes Accidentellement Exposees a de Fortes Doses de Rayonnement; 0417 041d 0410 0427 0414 ; Importancia de la Dosimetria para el Tratamiento Medico de las Personas Accidentalmente Expuestas a Dosis Elevadas de Radiaciones

    Andrews, G. A.; Lushbaugh, C. C. [Medical Division, Oak Ridge Institute of Nuclear Studies (United States); Auxier, J. A. [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1965-06-15

    Radiation accidents continue to occur sporadically and it appears that there is no hope of eliminating them entirely. The management of patients exposed to large doses of radiation is constantly improving because of increasing ability to prevent and treat infection and to control haemorrhage. The possible effectiveness of temporary bone marrow grafts offers promise of a further reduction in mortality. The use of this growing biological information is closely related to, and to a large extent dependent upon, improvements in physical dosimetry for radiation accidents. (author) [French] Des accidents provoques par les rayonnements continuent a se produire de temps a autre et il ne semble guere que l'on puisse esperer les eliminer entierement. Toutefois, le traitement des sujets exposes a de fortes doses de rayonnement ne cesse de s'ameliorer; on parvient, en effet, dans une mesure croissante a empecher et a traiter l*infection ainsi qu'a arreter l'hemorragie. Comme la greffe temporaire de la moelle des os semble devoir donner des resultats, on peut s*attendre a une nouvelle reduction du taux de mortalite. L'application de ces connaissances biologiques sans cesse accrues est fonction, dans une large mesure, des ameliorations apportees a la dosimetrie physique des accidents nucleaires. (author) [Spanish] De vez en cuando se siguen produciendo accidentes de irradiacion y las perspectivas de evitarlos por completo parecen ser bastante remotas. El tratamiento de las victimas expuestas a dosis elevadas de radiaciones mejora constantemente debido a la creciente posibilidad de prevenir y tratar las infecciones, y de controlar las hemorragias. Tambien es posible que la eficacia de ios injertos temporales de medula osea se traduzca en una disminucion de la mortalidad. El aprovechamiento de estos conocimientos biologicos cada vez mas amplios guarda una estrecha relacion con los perfeccionamientos en materia de dosimetria fisica en caso de accidentes de irradiacion. (author

  20. Dosimetric comparison fixed-individualized activity in the treatment of serious disease with I -131; Comparacion dosimetrica actividad fija-actividad individualizada en el tratamiento de la enfermedad de graves con I-131

    Melgar Perez, J.; Orellana Salas, A.; Santaella, Y.; Arrocha Acevedo, J. F.

    2013-07-01

    The iodine-131 therapy has become the treatment with radiopharmaceuticals more frequent in our country, as well as the largest source of exposure to ionizing radiation for members who surround the patient. The aim of this article is to analyse the recommendations of radiological protection which are delivered to the patient receiving radiation discharge, in terms of the duration of the same time, taking into account the radiopharmaceutical dose, the time of entry, the dose rate measured at one meter and the family environment among others. (Author)

  1. Treatment of solitary, autonomously-functioning, non-toxic thyroid nodules with I131 Adenema tiroideo autónomo no tóxico tratamiento con I131

    Federico Uribe Londoño

    1991-03-01

    Full Text Available

    Fifteen euthyroid patients (14 women and 1man with solitary autonomously functioning non-toxic thyroid nodules (AFTN were treated with high doses of I131 (mean 19.2 mCi. Diagnosis was made by I131 thyroid scan and triiodothyronine suppression test. The size of the nodule was determined by thyroid ecography both before and after treatment. Evaluation of thyroid function was performed clinically and by T3 T4 and TSH determinations before therapy and during follow.up. AII patients had complete suppression of the surrounding thyroid parenchyma. Two cases of hypothyroidism were found in the first two years of follow-up. We have no explanation for this fact since extranodular thyroid tissue was suppressed and the patients were receiving oral triiodothyronine during radioidine treatment. The nodules decreasedin size In 9 of 13 patients followed (average decrease 45% and disappeared in other 2. our findings suggest that solitary non-toxic AFTN should be treated with I131 particularly if complete suppression of the surrounding thyroid tissue is found. If complete disappearance of the nodule is considered desirable surgical removal must be performed.

    Se trataron 14 mujeres y un hombre, con adenomas tiroideos solitarios funcionalmente autónomos, no tóxicos, con I131 a una dosis promedio de 19.2 mCi. La gamagrafía tiroidea demostró hipercaptación del nódulo con supresión total del resto de la glándula. El tamaño del nódulo se determinó por medio de ecografía tiroidea antes y después del tratamiento, y su autonomía por la prueba de supresión con triyodotironina. El estado tiroideo se puso de presente clínicamente y por la medición de T3, T 4 y TSH en el plasma, antes de la terapia con el radiofármaco y durante la evolución postratamiento. En dos pacientes se presentó hipotiroidismo desde los dos primeros años del período de seguimiento, a pesar de que el tejido tiroideo circundante estaba suprimido y de la administración oral de triyodotironina simultáneamente con el yodo radioactivo. En 13 pacientes se logró hacer seguimiento; en 9 de ellos (69.2% hubo disminución del tamaño del nódulo (promedio de 45%; en dos desapareció y en otros dos no se modificó la lesión. Se sugiere que el tratamiento de los adenomas tiroideos autónomos no tóxicos con I131 es el más apropiado, especialmente si el tejido extranodular está suprimido; ello en vista de la Infrecuencia del hipotiroldismo postratamiento y de la inocultad y facilidad de su administración. Sin embargo, cuando se desea la desaparición total del adenoma y no existen contraindicaciones, debe recurrirse a la cirugía

  2. Dosimetric calculation of I-131 activity for the treatment to patients having differentiated thyroid cancer. Benefits and limitations; Calculo dosimetrico de la actividad de I-131 para tratamiento de pacientes con cancer diferenciado de tiroides (CADT). Beneficios y limitaciones

    Cabrejas, R. C.; Chebel, G. M.; Fadel, A. M.; Rojo, A. M.; Deluca, G.; Degross, O. J.; Valdivieso, C. M.; Carbejas, M. L.

    2006-07-01

    Maximum safe activity calculation, that has to be administered for treatment to patients having Differentiated Thyroid Cancer (CADT). No important side effects should be produced. Post treatment evolution was analysed. 23 Dosimetric studies were performed determining blood and whole body uptake curves (CE)during 5 days. Using the MIRDOSE software, the maximum safe activity in the whole body (CE)was calculated. The retained activity in the body (AR), 48 hs. post tracer dose. Should have been less than 2.96 GBq so as to avoid lung fibrosis. 17 patients that received activities<11.1 GBq, had no side effects. Three patients presents special situations: high AR, users in the mouth, and plaque to and leucopenia. This methodology has benefits because AT can be estimated. This was possible for 85% of the patients. When AR was high at 48 hr, AT was diminished to avoid pulmonary lesions. Tumor absorbed dose estimation, will allow the administration of AT>11.1 GBq in the future. (Author)

  3. Radiation exposure from liquid discharges from I-131 therapy rooms into a piping system in the building

    Tuntawiroon, M.; Sritongkul, N.; Pusuwan, P.; Chaudakshetrin, P.

    2007-01-01

    Full text: Over 80% of the activity from patients undergoing radioiodine therapy for thyroid cancer is eliminated during the first three days. In our iodine therapy unit, numbers of hospitalized patients have increased from less than 200 in 2004 to more than 300 patients in 2006. The total amount of activity used is about 1,900 MBq, and the estimated amount excreted would then be about 1,800 MBq. This results in significant volume of liquid discharges into the piping system. In this study, we monitored external dose rates in non-radiation areas adjacent to pipeline connections in the building to ensure that the dose to any individual in these areas does not exceed 1 mSv per year. Materials and Methods: Exposure rates in areas adjacent to the pipeline junction connections were measured periodically from April 2006 to February 2007, five floors below the therapy unit. The measurements were made inside the wall in contact with the junction, behind the wall and in hallways 1 meter from the wall, using a GM detector or an ionization chamber. The results were recorded in μSv/h and the dose received was estimated for members of the public. Results: Significant increases in dose rates were detected in three floors below the unit. They were 2030, 1025 and 515 Sv/h at contact with the pipeline connections, 915, 1015 and 35 μSv/h behind the wall, and 36, 56 and 25 μSv/h in hallways on floors 1, 2 and 3 respectively. After appropriate wall shielding had been provided, dose rate behind the wall reduced to 23 μSv/h, and to 0.52 μSv/h in hallways. By using an occupancy factor 1/4 for hallways, the calculated dose meets the public dose limits of 1 mSv per year. Conclusions: Therapeutic application of 131 I for the treatment of thyroid cancer generates a significant amount of liquid waste into the sewers. These low activity wastes originate mainly from toilets, showers, wash basins and floor drains. Although waste discharges can be handled without exceeding the permissible limits, there is possible exposure to the sewer workers if repairs become necessary. Appropriate precautions should be taken and radiation levels should be measured as the drain or sewer pipeline is opened up. (author)

  4. Analysis of influence of dosimetric factors on the outcome of I-131 therapy in patients with hyperthyroidism

    Knapska-Kucharska, M.; Oszukowska, L.; Makarewicz, J. [Department of Nuclear Medecine and Oncological Endocrinology, Province Hospital, Zgierz (Poland); Lewinski, A. [Chair and Department of Endocrinology and Metabolic Diseases, Medical University, Lodz (Poland)

    2012-07-01

    The influence of dosimetric factors on the outcome of {sup 131}I therapy has been examined in hyperthyroid patients submitted to {sup 131}I treatment. The following factors - which could have influence on the effects of therapy with radioiodine - were analysed: the goitre volume, the thyroid radioiodine uptake after 24 h, and the effective half-life time of {sup 131}I (EHL). Five hundred (500) randomly selected patients with hyperthyroidism, treated with {sup 131}I, were studied. They were divided into three groups (based on clinical examination, hormonal and immunological tests, thyroid scintigraphy and ultrasound imaging). The study shows that the effectiveness of {sup 131}I therapy depends on the thyroid volume and absorbed dose in all the groups of patients and on the thyroid radioiodine uptake and EHL in patients with a single autonomously functioning thyroid nodule. We have failed to determine the borderline D, distinguishing between effective and ineffective therapy. The treatment outcome can be predicted with approximately 70% accuracy, based on minimal absorbed dose

  5. The presence of I-131 in different environmental factors from N W of Romania after the Fukushima disaster

    Cosma, C.; Iurian, A.R.; Nita, D.C.; Begy, R.; Cindea, C.

    2011-01-01

    The earthquake that hit Japan in March 11, 2011, entailed a high radioactive release from Fukushima NPP during the next days. Based on the results of the reactors analysis, the Nuclear and Industrial Safety Agency from Japan (NISA) estimated that a total amount of 1.3x10 17 Bq 131 I and 6.1x10 15 Bq 137 Cs have been released into the atmosphere. The aim of this study is to quantify the Fukushima radioactivity contamination in Cluj county and surrounding areas of Transylvania region. The concentration of the fission products has been analyzed in rainwater, milk, vegetation, eggs and pollen during the period 28th of March, 2011 - 19th of April, 2011. The measurements have been carried out by means of gamma-spectroscopy, using two ORTEC spectrometers with HpGE detectors with 34.2% and 30% relative efficiency, respectively . The 364.5 keV gamma line was analysed to obtain the 131 I concentrations and Maestro software has been used for the automatic spectrum evaluation. The 134 Cs and 137 Cs nuclides were also analysed as based on the gamma line from 604.7 keV and 661 keV, respectively. Some measurements were also performed for aerosol iodine collected on paper filters. The 131 I was the first radionuclide detected in rainwater from Cluj-Napoca, in 28th of March 2011. In April 5, 2011, the sheep milk registered a maximum activity of 9.22 ± 0.95 Bq/l in Cluj area. It seems that the maximum level of radioiodine concentration in the N W region of Romania has been reached at around 4th of April, 2011. The results obtained for rainwater at the beginning of April are in accordance with the measurements carried out in Pitesti area for radioiodine in air and wet depositions. The 134 Cs has been found only in rainwater at the beginning of March. The values recorded for 137 Cs in rainwater were close to the detection limit of the spectrometer, being subject of uncertainty due to the suspension in atmosphere of this artificial radionuclide also from Chernobyl accident release. The comparing the milk and vegetation samples showed a smaller amount of 131 I, without exceeding 1.54 ± 0.15 Bq/kg found in grass in 10th of April, 2011. By acting as filters for the fission products from the atmosphere, the pollen and moss samples seem to be good indicators of the radioactive contamination. It could be concluded that the radioactive fallout from Fukushima NPP had insignificant values in the N W of Romania, if the maximum admitted levels for 131 I, 137 Cs and 134 Cs and the level of natural background are taken into account. (authors)

  6. The effect of newer water-soluble contrast media on I-131 uptake by the thyroid gland

    Starinsky, R.; Horne, T.; Barr, J.; Ramot, Y.

    2006-01-01

    The aim of this study was to evaluate the effect of two water-soluble contrast media (nonionic and Dimer) on iodine uptake by the thyroid gland. Twenty-eight euthyroid patients (16 females and 12 males) were subjected to 24hrs radioiodine uptake (RAIU) studies following brain CT examinations using the above cited two water-soluble contrast media. Radioiodine uptake studies were done at one (Group-1), two (Group-2) and four (Group-3) weeks following performance of contrast enhanced CT scans. The effect of both contrast media on the thyroid uptake was found to be identical. The radio active iodine uptake (RAIU) was observed to be suppressed in 30% of patients in Group-1, 33% of patients in Group-2 and in none of the patients belonging to Group-3. On the basis of this pilot study on a limited number of patients it was concluded that dimer and non-ionic water soluble contrast media cause suppression of radio iodine uptake by the thyroid gland in a significant proportion of patients. It has also been observed that both contrast media have similar suppressive effects on radio iodine uptake by the thyroid gland. This effect is transient and does not persist beyond a period of four weeks following the administration of the contrast media. (author)

  7. Diet low in iodine as well as goitrogens (LILGD) enhanced radioiodine (I-131) uptake in treatment of differentiated thyroid cancer

    Aaro, Erik; Gebre-Medhin, Mehari; Lindahl, Sten-AAke

    2005-01-01

    Full text: Low iodine diet (LID) is accepted as an adjuvant to post-thyroidectomy radioiodine therapy of differentiated thyroid cancer since it is held to enhance radioiodine uptake in thyroid remnants and thyroid cancer tissue. However, in the few clinical investigations performed only an indirect and weak evidence of a positive effect of the LID has been demonstrated. Also we had discouraging experience in the application of a strict LID using the same design as in the present study. We therefore decided to investigate the effect of a diet low in iodine as well as in goitrogens (LILGD). Methods: Six patients with differentiated thyroid cancer entered the study and they were their own control. After thyroid hormone withdrawal (TSH > 30 m U/L) and on regular diet a diagnostic whole body scan was performed 24 h after administration of 50 MBq (1,4 mCi) 123 I. The day following diagnostic scan the patients were put on LILGD for 4 days prior and two days after radioiodine therapy. In LILGD beverages, fruits and vegetables containing flavonoids, glucosinolates, cyanides and thiocyanates were avoided and spices and smoking prohibited. Therapeutic radioiodine was administered one week after diagnostic procedures and in the morning after over-night fasting with an activity range of 3,7-5,4 GBq (100 -150 mCi) 131 I. A 24-h therapeutic whole body scan and calculations of percentage uptake U(24) were performed. Diagnostic (basal) D U(24)% and subsequent therapeutic T U(24)% uptake were compared and expressed as therapeutic/diagnostic uptake ratios T/D U(24). Results: A significant increase in therapeutic versus diagnostic uptake T/D U(24) was observed (mean 2,53, median 2,30, range 1,40 - 4,46, p 131 I uptake in radio-ablation of normal and thyroid cancer tissue. (author)

  8. Potassium iodide (KI) to block the thyroid from exposure to I-131: current questions and answers to be discussed

    Reiners, Christoph; Schneider, Rita [Hospital of the University of Wuerzburg, Department of Nuclear Medicine, German WHO-REMPAN Collaboration Center, Wuerzburg (Germany)

    2013-05-15

    Thyroid cancer in children and adolescents has to be considered as the most severe health consequence of a nuclear reactor emergency with release of radioiodine into the atmosphere. High doses of potassium iodide are effective to block radioiodine thyroid uptake and to prevent development of thyroid cancer years later. However, there are controversies concerning thyroid cancer risk induced by radioiodine exposure in adults. Further, the interaction of nutritional supply of potassium iodide and radioiodine uptake as well as the interaction of radioiodine with certain drugs has not been addressed properly in existing guidelines and recommendations. How to proceed in case of repeated release of radioiodine is an open, very important question which came up again recently during the Fukushima accident. Lastly, the side effects of iodine thyroid blocking and alternatives of this procedure have not been addressed systematically up to now in guidelines and recommendations. These questions can be answered as follows: in adults, the risk to develop thyroid cancer is negligible. In countries, where nutritional iodine deficiency is still an issue, the risk to develop thyroid cancer after a nuclear reactor emergency has to be considered higher because the thyroid takes up more radioiodine as in the replete condition. Similarly, in patients suffering from thyrotoxicosis, hypothyroidism or endemic goitre not being adequately treated radioiodine uptake is higher than in healthy people. In case of repeated or continued radioiodine release, more than one dose of potassium iodide may be necessary and be taken up to 1 week. Repeated iodine thyroid blocking obviously is not harmful. Side effects of iodine thyroid blocking should not be overestimated; there is little evidence for adverse effects in adults. Newborns and babies, however, may be more sensitive to side effects. In the rare case of iodine hypersensitivity, potassium perchlorate may be applied as an alternative to iodine for thyroid blocking. (orig.)

  9. Analysis of influence of dosimetric factors on the outcome of I-131 therapy in patients with hyperthyroidism

    Knapska-Kucharska, M.; Oszukowska, L.; Makarewicz, J.; Lewinski, A.

    2012-01-01

    The influence of dosimetric factors on the outcome of 131 I therapy has been examined in hyperthyroid patients submitted to 131 I treatment. The following factors - which could have influence on the effects of therapy with radioiodine - were analysed: the goitre volume, the thyroid radioiodine uptake after 24 h, and the effective half-life time of 131 I (EHL). Five hundred (500) randomly selected patients with hyperthyroidism, treated with 131 I, were studied. They were divided into three groups (based on clinical examination, hormonal and immunological tests, thyroid scintigraphy and ultrasound imaging). The study shows that the effectiveness of 131 I therapy depends on the thyroid volume and absorbed dose in all the groups of patients and on the thyroid radioiodine uptake and EHL in patients with a single autonomously functioning thyroid nodule. We have failed to determine the borderline D, distinguishing between effective and ineffective therapy. The treatment outcome can be predicted with approximately 70% accuracy, based on minimal absorbed dose

  10. Thyroid carcinoma after radioiodide therapy for hyperthyroidism. Analysis based on age, latency, and administered dose of I-131

    Spencer, R.P.; Chapman, C.N.; Rao, H.

    1983-01-01

    Twenty-five reports in the medical literature of thyroid carcinomas which were detected after radioiodide therapy for hyperthyroidism were reviewed. These cases did not show a usual characteristic of radiation-associated tumors, namely a long latency period. That is, in 8/25 the latency period was under five years, and the mean latency was only 7.3 years. Further, there was no relationship between latency and age at treatment, or between latency and the dose of radioiodide employed. In 15/25 of the cases, there were known thyroid nodules. Three of the patients had thyroiditis (which itself has a correlation with thyroid carcinoma), and one individual had prior head and neck external radiation. There was no substantiating evidence that radioiodide treatment for hyperthyroidism was the cause of these thyroid carcinomas

  11. A Low-Background Liquid-Scintlllation Counter for the Assay of Low-Specific Activity Tritiated Water; Compteur a scintillations a liquides, a faible mouvement propre, pour le dosage d'eau tritiee en faible activite specifique; ZHidkostnyj stsintillyatsionnyi schetchik s nizkim fonom dlya analiza nasyshchennoj tritiem vody s nizkoj udel'noj aktivnost'yu; Contador de centelleador liquido de reducida actividad de fondo para el analisis de agua pritiada de baja actividad especifica

    Boyce, I S; Cameron, J F [Wantage Research Laboratory, Wantage (United Kingdom)

    1962-01-15

    emana del fotocatodo del fotomultiplicador. Utilizando dos fotomultiplicadores con fotocatodos de pyrex en contacto, encerrados en un blindaje de hierro de 20 cm de espesor, hicieron experimentos para determinar la importancia relativa de las siguientes posibles causas de la actividad de fondo: a) Ionizacion y excitacion del gas residual y de las superficies del dinodo semiconductor, especialmente en las regiones en que la densidad de corriente es maxima; b) Formacion de chispas, electroluminiscencia y emision de campo; c) Realimentacion de iones positivos al fotocatodo, que provoca una emision de electrones, secundarios ; d) Funcionamiento de la propia ventana fotocatodica en caracter de ''fosforo'' para la radiacion cosmica, las particulas del {sup 40}K o las radiaciones de los productos de filiacion del uranio. Los autores comprobaron que, en particular, el factor c) interviene en una proporcion mucho menor que lo que se habia supuesto. Estudiaron metodos para reducir a un minimo estos efectos, incluyendo el uso de fotocatodos de cuarzo y fotomultiplicadores especiales. Con el dispositivo disenado por los autores, la minima actividad especifica detectable, con un tiempo de recuento de 30 min, asciende a 6 x 10{sup 7}{mu}c/ml. (author) [Russian] Pri schege zhidkostnykh stsintillyatsij nasytsennoj tritiem vody schetchiki s odnim fotoumnozhitelem i sistemy sovpadenij dayut pokazaniya sravnitel'noj chuvstvitel'nosti. Dlya issledovaniya scheta izlucheniya maloj intensivnosti byla primenena sistema sovpadenij dlya togo, chtoby izbezhat' neopredelennosti v fone, vyzyvaemom izmeneniemi odnogo fotona v rezul'tate fosforestsentsii i khimicheskoj lyuminestsentsii v rastvore. Bylo obnaruzheno, chto vozniknovenie fona v ehtoj sisteme ob{sup y}asnyaetsya glavnym obrazom dejstviem sveta, iskhodyashchego iz fotokatoda fotoumnozhitelya. Byli provedeny ksperimenty s primeneniem dvukh fotoumnozhitelej s fotokatodami Pireks v kontakte s zheleznym ehkranom tolshchinoj v 8 dyujmov dlv

  12. Aptitud combinatoria general y especifica de líneas tropicales de maiz usando probadores

    Mauro Sierra

    2000-01-01

    Full Text Available Aptitud combinatoria general y específica de líneas tropicales de maíz usando probadores. Durante el ciclo O - I 1996/97 fueron evaluados en el Campo Experimental Cotaxtla mestizos de líneas sobresalientes y provenientes de varias fuentes de germoplasma como son : a Líneas recicladas de H-513 X VS-536, b Líneas derivadas de un compuesto de amplia base genética, c Líneas élite de programa de maíz de Cotaxtla (LTs y d Líneas de CIMMYT (CMLs. Como probadores se usaron las líneas LT-154 y LT-155 progenitores del híbrido H-513 y las líneas CML247 y CML254 cuya cruza es un patrón heterótico definido por CIMMYT para el trópico. Hubo líneas con buen comportamiento per-se tanto en rendimiento como en características agronómicas y que se encuentran formando mestizos sobresalientes con uno o varios probadores. Con relación a la Aptitud combinatoria, se encontró que las líneas F31XF30-4-3-1, F41XF40-1-2-1, CABG3’-12-2-1-2-1-1, LT174 y CML15 registraron los máximos valores con el probador 2 (LT155; F4XF3-5-2-1 y CML15 con el probador 4 (CMl254. Así también, las líneas F4XF5-5-1-1, y CABG3’-12-2-1-2-1-1, LT174, CML13 y CML15 con buena ACG. Con relación a los probadores, se encontró que para el grupo de líneas Recicladas , los probadores 1(LT154 y 4 (CML254 registraron los coeficientes de regresión más altos, lo que indica que permiten identificar líneas sobresalientes. Para líneas CABG fué el probador 2 (LT155 el que registró el mejor valor y en líneas Élite , los probadores 2(LT155, y 3(CML247 identificaron mejor a las líneas sobresalientes. Para las líneas del CIMMYT el mejor valor fué para el probador 4(CML254

  13. Obtención de secuencias microsatelitales especie especificas para Plagioscion magdalenae (Pisces:Sciaenidae

    Natalia Juliana Bayona-Vásquez

    2007-08-01

    en la parte baja de la cuenca del río Magdalena y en la cuenca del río San Jorge, Colombia, en donde cada vez su comercialización cobra fuerza debido al desplazamiento y disminución en los volúmenes de captura de otras especies como el bagre rayado y bocachico. Lo cual ha llevado a la comúnmente llamada pacora a catalogarse en estado de vulnerabilidad en las cuencas colombianas. Lo anterior, hace necesario la generación de información que sirva de sustento a programas de conservación y uso sostenible de la especie. Una primera aproximación a las poblaciones de P. magdalenae puede ser hecha a través de marcadores moleculares microsatelitales, útiles en trabajos de genética de poblaciones, conservación y manejo de recursos biológicos. Sin embargo, la principal dificultad de los microsatélites es que deben ser aislados de novo para aquellas especies que van a ser evaluadas por primera vez, lo que lleva a la necesidad de obtener primers para la especie. En este trabajo, inicialmente se obtuvo un ADN de buena calidad útil para amplificaciones a partir de muestras de músculo colectadas en cuatro puntos de la cuenca del río San Jorge; posteriormente, se aislaron primers microsatelitales especie-específicos para P. magdalenae mediante amplificación cruzada con primers de otras especies de peces lejanas, entre las cuales se encuentra: Pseudoplatystoma corruscans, Pimelodella chagressi, Prochilodus argenteus y Prochilodus costatus. Para lo anterior, fue necesario modificar y estandarizar protocolos de amplificación mediante cambios en temperatura de alineamiento y concentración de reactivos; y por último se realizó el secuenciamiento de regiones flanqueantes y motivos de repetición en aquellos sistemas que presentaron resultados positivos, de esta forma, se diseñaron primers de regiones microsatélite para la especie. De los trece sistemas evaluados, de las cuatro especies, se obtuvo amplificación positiva de seis. Por medio de la técnica expuesta es posible aislar de manera económica y eficiente (cerca de un 50% de resultados efectivos, regiones microsatelitales útiles para estudios posteriores en peces.

  14. Ontoprolog: uma linguagem para especificação de discursos sobre ontologias

    Lauro César Araujo

    Full Text Available RESUMO Este artigo introduz a arquitetura da informação de uma linguagem formal textual para representar e obter deduções a respeito problemas reais com base em ontologias de domínio e ontologias de fundamentação. O arcabouço é desenvolvido com base em Programação em Lógica, e consiste em uma linguagem formal que utiliza o paradigma de metamodelagem para produzir ontologias heterogêneas que podem ser descritas como instâncias de ontologias de fundamentação.

  15. Biological dosimetry, scopes and limitations; Dosimetria biologica, alcances y limitaciones

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Salazar, Estado de Mexico (Mexico)

    1999-07-01

    The analysis of the aberrations in chromosomes is an alternative to establish the exposure dose to the radiation, when the information provided by the traditional physical methods is insufficient. There are diverse causes by which it can reached to apply an alternative system, such is the case of exposures of another persons to the management of radiation sources, which not carry physical dosemeter. Contrary case is to the occupational exposure personnel (OEP), what must to utilize some system for determining the exposure dose, even so can be needed the case for more information. In any case, the cells from the affected person are the alternative without the biological system be overlap to the physical, it is complementary. (Author)

  16. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  17. The personal dosimetry in Mexico; La dosimetria personal en Mexico

    Salazar, M.A. [Proxtronics/ Asesoria Integral en Dosimetria Termoluminiscente S.A. de C.V., Canal de Miramontes 2030-14, Col. Educacion, 04400 Mexico D.F. (Mexico)]. e-mail: aidtsa@avantel.net

    2006-07-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it is for what is considered that this work is important since the main objective of the Personal Dosimetry is that of the protection of people, that is to say the one of avoiding risks in the health of the workers involved with the radiations. (Author)

  18. Dosimetry of industrial sources; Dosimetria de fuentes industriales

    Vega C, H.R.; Rodriguez J, R.; Manzanares A, E.; Hernandez V, R.; Ramirez G, J. [Universidad Autonoma de Zacatecas, 98068 Zacatecas (Mexico); Rivera M, T. [CICATA-IPN, 11500 Mexico D.F. (Mexico)]. e-mail: fermineutron@yahoo.com

    2007-07-01

    The gamma rays are produced during the disintegration of the atomic nuclei, its high energy allows them to cross thick materials. The capacity to attenuate a photons beam allows to determine the density, in line, of industrial interest materials as the mining. By means of two active dosemeters and a TLDs group (passive dosimetry) the dose rates of two sources of Cs-137 used for determining in line the density of mining materials were determined. With the dosemeters the dose levels in diverse points inside the grave that it harbors the sources and by means of calculations the isodoses curves were determined. In the phase of calculations was supposed that both sources were punctual and the isodose curves were calculated for two situations: naked sources and in their Pb packings. The dosimetry was carried out around two sources of {sup 137}Cs. The measured values allowed to develop a calculation procedure to obtain the isodoses curves in the grave where the sources are installed. (Author)

  19. Relative dosimetry by Ebt-3; Dosimetria relativa por EBT3

    De Leon A, M. A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico); Hernandez O, J. O., E-mail: madla16@hotmail.com [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Mexico D. F. (Mexico)

    2015-10-15

    In the present work relative dosimetry in two linear accelerator for radiation therapy was studied. Both Varian Oncology systems named Varian Clinac 2100-Cd and MLC Varian Clinac i X were used. Gaf Chromic Ebt-3 film was used. Measurements have been performed in a water equivalent phantom, using 6 MV and 18 MV photon beams on both Linacs. Both calibration and Electron irradiations were carried out with the ionization chamber placed at the isocenter, below a stack of solid water slabs, at the depth of dose maximum (D max), with a Source-to-Surface Distance (SSD) of 100 cm and a field size of 10 cm x 10 cm. Calibration and dosimetric measurements photons were carried out under IAEA-TRS 398 protocol. Results of relative dosimetry in the present work are discussed. (Author)

  20. Dosimetry of {beta} extensive sources; Dosimetria de fuentes {beta} extensas

    Rojas C, E.L.; Lallena R, A.M. [Departamento de Fisica Moderna, Universidad de Granada, E-18071 Granada (Spain)

    2002-07-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of {beta} extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  1. Retrospective dosimetry in irradiated foods; Dosimetria retrospectiva en alimentos irradiados

    Calderon, T [Universidad Autonoma de Madrid, Facultad de Ciencias, Dpto. Quimica Agricola, Geologia, Geoquimica, Cantoblanco, Madrid (Spain)

    1999-07-01

    The main objective of this communication is to show the potentiality of certain minerals which accompany the foods (grasses, spices and seasonings) as potential dosemeters and its possible application in the absorbed dose calculations by the same in its hygienic sanitary treatment. (Author)

  2. Dosimetry of High-Energy Protons by Measurement of Beryllium-7 Formed in the Tissues; Dosimetrie des Protons de Haute Energie par Mesure de Beryllium-7 Forme dans les Tissus; 041e 0422 041d 041e 0421 0414 ; Dosimetria Relativa Mediante Berillo-7 Despues de Irradiar con Protones de Altas Energias (600 Mev Y 3 Gev)

    Legeay, G. [Service Biologique et Veterinaire des Armees, Detache au D.P.S. (France); Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses (France); Court, L.; Prat, L [Service de Sante des Armees, Detaches au D.P.S. (France); Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses (France); Jeanmaire, L.; Daburon, M. L. [Commissariat a l' Energie Atomique (France); Nucleaires de Fontenay-aux-Roses, Centre d' Etudes [France; De Kerviler, H.; Tardy-Joubert, P. [Service de Protection Contre les Radiations, Centre d' Etudes Nucleaires de Saclay (France)

    1965-06-15

    compara las actividades determinadas experimentalmente y las calculadas en funcion de la energia a partir de los valores de las secciones eficaces actualmente admitidos. Dado que la irradiacion accidental del ser humano en haces protonicos es siempre localizada, se han efectuado experimentos consistentes en la irradiacion de la cabeza de conejos Fauve de Bourgogne de unos 2 kg de peso. Se comprobo que la actividad inducida en la cabeza es, en relacion a la que se observa en el resto del cuerpo, del orden de 1,8 {+-} 5. A pesar de cierta difusion el {sup 7}Be se puede detectar durante los primeros dias que siguen a la irradiacion. Por tanto, queda demostrado que este tipo de dosimetria relativa permite formarse una idea concreta del orden de magnitud de la irradiacion recibida accidentalmente. (author) [Russian] V ramkah biologicheskih jeksperimentov, provedennyh na sinhrociklotrone issledovatel'skogo jadernogo centra CERN v Zheneve s primeneniem protonov v 600 Mjev, i na sinhrotrone ''Saturn'' v issledovatel'skom jadernom centre Sakle s pomoshh'ju gamma-spektrografii, issledovalas' navedennaja radioaktivnost' u zhivyh sushhestv. I esli bol'shinstvo navedennyh radioizotopov (gamma-izluchatelej) imejut ochen' korotkij period poluraspada, to berillij-7, poluchaemyj v rezul'tate reakcij rasshheplenija na atomah kisloroda, ugleroda i azota, v chastnosti, daet pik aktivnosti, kotoryj bystro otdeljaetsja ot vsego spektra pri urovne jenergij v 479 kjev. Period poluraspada berillija-7 ravnyj 54,5 dnja pozvoljaet registrirovat' ego v techenie dostatochno prodolzhitel'nogo vremeni. Issledovanie, provedennoe Uajcarom na krysah, kotorye byli oblucheny in toto dozami mezhdu 400 i 800 rad, s protonami v 600 Mjev, i dozami 200 i 1000 rad, s protonami v 3 Gjev, daet linejnuju harakteristiku aktivnosti berillija-7 v zavisimosti ot pogloshhennoj dozy na 1 g tkani. Jeksperimental'nye rezul'taty sravnivalis' s raschetnymi, proizvedennymi s uchetom zavisimosti ot jenergii i na baze sechenij

  3. Planned Procedures for Fast Determination of Radiation Levels and Personnel Dosimetry in Connection with Radiological Accidents; Methodes de Dosimetrie Rapide du Personnel en Cas d'Accident Radiologique; 041f 041b 0410 041d 0414 ; Servicio Organizado de Determinacion Rapida de los Niveles de Radiacion y de Dosimetria del Personal en Caso de Accidente Radiologico

    Edvardsson, K. -A.; Wahlberg, T. [AB Atomenergi, Studsvik (Sweden)

    1965-06-15

    medios de comunicacion con el interior y con el exterior. En materia de dosimetria individual, interesa, a la vez obtener lo antes posible los datos preliminares aproximados de la intensidad de la exposicion interna y externa, asi como, dentro de un plazo prudencial, datos bastante exactos, de la exposicion a que ha estado expuesta cada persona. Diversos equipos de determinacion de dosis, conocidos con el nombre de patrullas de reconocimiento, recorren los diversos sectores del recinto de la instalacion a fin de efectuar una evaluacion general de los riesgos. Esas patrullas que entran en accion tan pronto como se recibe la alarma estan provistas de instrumentos portatiles y recorren en automovil una serie de itinerarios previamente determinados en el emplazamiento. Los ensayos practicos realizados han puesto de manifiesto que las informaciones reunidas por las diversas patrullas llegan a la oficina central transcurridos 10-15 min despues de darse la alarma, permitiendo obtener una vision clara de los niveles de radiacion dentro y fuera de los diversos edificios. Los aparatos portatiles incluyen dispositivos para muestreo rapido del aire que funcionan segun el principio del eyector de aire. Las dosis individuales de irradiacion externa se evaluan con ayuda de dosimetros de pelicula, por activacion de dosimetros de criticidad, asi como por analisis de la actividad del pelo y de la sangre. La contaminacion interna se determina mediante antropogammametria y analisis radiometrico de las excreta. Para delimitar los campos de radiacion creados por un accidente, existen diversos puntos fijos de control equipados con dosimetros de varios tipos, a cuya lectura se procede lo antes posible despues de producirse el supuesto accidente. (author) [Russian] Obshhestvo po atomnoj jenergii Shvecii imeet special'nuju avarijnuju organizaciju, kotoraja nachinaet funkcionirovat' kak tol'ko poluchen signal o tom, chto sozdalos' chrezvychajnoe polozhenie v svjazi s bol'shoj radiacionnoj opasnost

  4. In Vivo and Air Dosimetry of Fission-Spectrum Neutrons; Dosimetrie In Vivo et dans l'Air du Spectre des Neutrons de Fission; Dozimetriya v vozdukhe i dozimetriya In Vivo nejtronov spektra deleniya; Dosimetria In Vivo y en el Aire de Neutrones de un Espectro de Fision

    Mobley, T. S.; Engel, R. E.; Godden, W. R. [Kirtland Airforce Base, New Mexico (United States); Penikas, V. T. [AFIT, Wright-Patterson Air Force Base, Ohio, with Duty Station at University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States)

    1964-03-15

    laterales a une distance mediane de 200 cm ou de 175 cm du centre de l ' assemblage critique. La dose de neutrons mesuree dans l ' air etait de 161 {+-} 5 ,5 rad a 200 cm et de 242 {+-} 16.6 rad a 175 cm. A ces distances, la dose gamma etait respectivement de 33 {+-} 2,4 et 42 {+-} 2,5 r. Les doses d'entree et de sortie ainsi que la dose a l ' insertion variaient selon l'elevation de temperature due aux bouffees de neutrons, la distance du reacteur, l 'orientation des feuilles par rapport au reacteur et l'epaisseur et la composition de tissus attenuants. (author) [Spanish] Con el proposito de evaluar la configuracion de la dosis profunda durante la exposicion a neutrones de un espectro de fisionalos autores han ideado un metodo de dosimetria neutronica in vivo que aplicaron a ovejas. Utilizaron para estos estudios un reactor pulsante analogo al GODIVA II del Laboratorio Cientifico de Los Alamos. Dicho conjunto funciona de forma de producir impulsos de 50 {mu}s de amplitud, medida a la mitad de la altura maxima, y un ascenso de temperatura del combustible de unos 100 Degree-Sign C. Ademas, prepararon 'apositos ' subcutaneos que contienen una lamina de oro recubierta de cadmio, una lamina de oro sin recubrir y tres dosimetros de varilla de vidrio, termoluminiscentes, en un recipiente de plomo al litio revestido de vidrio. Estos apositos se introdujeron en el tejido subcutaneo, a ambos lados del cuerpo, y sirvieron para medir el flujo integrado de neutrones termicos y la dosis gamma, a medida que la irradiacion neutronica se aplica 'lateralmente'. Los apositos abdominales se prepararon en forma semejante a los subcutaneos; constan de una esfera de boro que contiene laminas de umbral de fision (Pu, Np, U) recubiertas de cadmio, una pastilla de azufre y los mismos tres tipos de dosimetros que forman parte del aposito subcutaneo. El aposito dosimetrico se sujeto al pilar anterior del rumen del animal 18 h antes de someterlo a la exposicion. En la memoria se describe la tecnica de

  5. Nuclear Accident Dosimetry at Argonne National Laboratory; Dosimetrie dans les Cas d'Accidents Nucleaires au Laboratoire National d'Argonne; 0421 041b 0423 0416 0411 0410 0414 ; Dosimetria en Casos de Accidente Nuclear en el Laboratorio Nacional de Argonne

    Anderson, L. L.; Duffy, T. L.; Sedlet, J.; O' Neil, D. P. [Argonne National Laboratory, Argonne, IL (United States)

    1965-06-15

    cellules au cuivre, a l'indium et aux composes du soufre. Les auteurs calculent la fluence totale des neutrons en utilisant le spectre corrige en conjonction avec une fonction de probabilite de capture et le resultat pour le sodium du sang. On peut alors obtenir une ou plusieurs specifications de la dose des neutrons, en appliquant la fonction de conversion appropriee aux renseignements obtenus sur le spectre. L'element de l'ensemble dosimetre primaire destine a mesurer les rayons gamma contient des baguettes fluorescentes et un dosimetre a thermoluminescence en plus du dosimetre chimique a deux phases. Le dosimetre gamma de l'ensemble secondaire est une.solution de polyacrylamide qui se degrade sous l'effet des rayons gamma. On calcule la dose absorbee a partir de la valeur mesuree du changement de viscosite de la solution. Le memoire signale les difficultes que presentent l'evaluation des resultats, le choix de l'emplacement et la stabilite pendant le stockage. Des methodes sont etablies pour le dosage du phosphore-32 dans les matieres biologiques, lequel vise a obtenir la dose de neutrons rapides, a analyser les matieres prelevees dans le milieu ambiant pour y doser les produits resultant de l'activation par les neutrons et a determiner le nombre total de fissions. Le controle administratif des operations de dosimetrie est facilite par un manuel qui enumere les emplacements des appareils, precise les methodes de manipulation et de comptage et donne les formules de calcul de la dose. (author) [Spanish] El informe resume las medidas cuya adopcion se preve actualmente en el Laboratorio Nacional de Argonne para evaluar las dosis recibidas a consecuencia de un accidente de criticidad. Discute principalmente dos tipos de dosimetro que se encuentran en el comercio e indica los resultados de calibraciones independientes que se ejecutaron en el citado laboratorio. La red primaria de dosimetria esta constituida por detectores de umbral perfeccionados en el Laboratorio Nacional de

  6. Method of obtaining concentrated preparations of Cl{sup 36} and Br{sup 82} by recoil nuclei under exposure to high-density neutron fields; Preparation de composes du chlore-36 et du brome-82 de haute activite specifique, par exposition de noyaux de recul a des champs neutroniques intenses; Poluchenie kontsentrirovannykh preparatov Cl{sup 36} i Br{sup 82} metodom yader otdachi pri obluchenii v nejtronnykh polyakh vysokoj plotnosti; Obtencion de compuestos de cloro-36 y de bromo-82 de alta actividad especifica por retroceso de nucleos en campos neutronicos intensos

    Kurchatova, L N; Kurchatov, B V

    1962-01-15

    radiactivos concentrados suele considerarse poco eficaz cuando se utilizan intensidades elevadas de flujo integrado de neutrones, debido al alto grado de descomposicion de la sustancia irradiada. Los autores han encontrado compuestos de carbono que contienen bromo o cloro y que permiten enriquecer considerablemente estos elementos en sus isotopos radiactivos por efecto de retroceso durante la exposicion a flujos neutronieos del orden de 10{sup 13} n/cm{sup 2} s. Estos compuestos responden a la formula C{sub n}X, en la que X = Cl o Br, y n = 10-20 para los compuestos clorados, y 25-70 para los compuestos del bromo. Son bastante estables termica y quimicamente. Los compuestos de formula C{sub 30}Br soportan temperaturas de hasta 300{sup o} C en una atmosfera de argon, sin desprendimiento de bromo ; se descomponen por completo a 600{sup o} C. Las soluciones acuosas de agentes reductores los dejan practicamente inalterados. Los compuestos de cloro y carbono son casi tan estables como los de bromo y carbono. Solo los agentes reductores muy energicos (por ejemplo, una solucion sulfurosa de CrSO{sub 4}) separan lentamente el cloro a temperatura ambiente. El enriquecimiento del bromo en su isotopo {sup 82}Br utilizando estos compuestos de bromo y carbono aumenta de 50 a 500 veces en flujos integrados del orden de 5 x 10{sup 17} n/cm2. La actividad especifica del concentrado oscila entre 6 y 35 mc/mg de bromo y, probablemente, podria aumentarse perfeccionando el metodo. La estructura del compuesto permite aislar con buen rendimiento hasta el 75 por ciento del bromo radiactivo recurriendo a una tecnica muy sencilla. Se ha demostrado que el sistema carbono-cloruro de hierro-cloro es el mas eficaz para obtener cloro-36 en forma concentrada. Este sistema hizo posible aumentar de 6 a 20 veces el enriquecimiento, siendo la actividad especifica del concentrado de 230-255 {mu}c/g de cloro. El efecto de concentracion cuando se irradian con neutrones los compuestos clorados y bromados es el

  7. Bilateral renal metastasis of 261-265huerthle cell thyroid cancer with discordant uptake between I-131 sodium iodide and F-18 FDG

    Claimon, Apichaya; Suh, Min Seok; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June Key [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, E. Edmund [Dept. of Radiological Sciences, University of California, Irvine (United States)

    2017-09-15

    Renal metastasis of thyroid cancer is extremely rare. We report the case of a 62-year-old woman with Hürthle cell thyroid cancer (HCTC) with lungs, bones, and bilateral kidneys metastases. The renal metastatic lesions were clearly demonstrated by {sup 131}I whole body scan (WBS) with SPECT/CT. However, they exhibited false-negative results in {sup 18}F-FDG PET/CT, kidney ultrasonography, and contrast-enhanced CT scan. The findings imply that tumors have low glucose metabolism and are able to accumulate radioiodine, which is not commonly found in the relatively aggressive nature of HCTC. The patient received two sessions of 200 mCi {sup 131}I therapy within 6 months duration. There was complete treatment response as evaluated by the second post-therapeutic {sup 131}I SPECT/CT and serum thyroglobulin. To our knowledge, renal metastasis from HCTC with positive {sup 131}I but negative {sup 18}F-FDG uptake has not been reported in the literature. This case suggests that {sup 131}I SPECT/CT is useful for lesion localization and prediction of {sup 131}I therapy response.

  8. Comparison between a commercial solid-phase extraction cartridge and a home-made silver containing charcoal column: purification of Mo-99 from I-131 and Te-121

    Dias, Carla Roberta; Teodoro, Rodrigo; Osso Junior, Joao

    2011-01-01

    Among the radioisotopes used for medical application in Nuclear Medicine, 99m Tc, readily available from the elution of 99 Mo/ 99m Tc generators, is the most used, responsible for more than eighty percent of the total applications. These generators use the 99 Mo radioisotope that is produced in nuclear reactors and IPEN imports all the 99 Mo used in Brazil, mainly from Canada (Nordion). Due to the increasing needs of the Nuclear Medicine in Brazil and the world shortage of 99 Mo observed since 2008, IPEN decided to construct a new research reactor named Brazilian Multipurpose Reactor (BMR) as well as to develop the production of 99 Mo through the route of 235 U fission using a CINTICHEM modified separation process. The 99 Mo obtained from this process contains some contaminants and need to be purified. The aim of this work is to compare the preliminary results of the purification step of the solution containing 99 Mo and the contaminants, 131 I and 121 Te in the silver containing charcoal column and a solid-phase extraction cartridge. The purification process of 99 Mo coming from fission LEU foils was performed by adsorption chromatography using a home-made activated charcoal containing silver column (AC-Ag) and a commercial solid-phase extraction cartridge (OnGuard II Ag). High yields of 99 Mo elution and high retention of 131 I were achieved in the AC-Ag column and silver cartridge but 121 Te was more retained in the cartridge than in the AC-Ag column. (author)

  9. Iodine I 131 Monoclonal Antibody BC8 Before Autologous Stem Cell Transplant in Treating Patients With Relapsed or Refractory Hodgkin Lymphoma or Non-Hodgkin Lymphoma

    2017-11-15

    Recurrent B-Cell Non-Hodgkin Lymphoma; Recurrent Hodgkin Lymphoma; Recurrent T-Cell Non-Hodgkin Lymphoma; Refractory B-Cell Non-Hodgkin Lymphoma; Refractory Hodgkin Lymphoma; Refractory T-Cell Non-Hodgkin Lymphoma

  10. Radiation exposure by radio-iodine release of the planned nuclear power plant Wyhl. Expert's opinion on thyroid exposure due to radioactive I-131

    Bleck-Neuhaus, J

    1981-01-01

    The radioecology of iodine-131 in the off-air of a nuclear power plant is subject to investigation of the critical exposure pathway air - pasture ground - cow - milk. According to the findings on the factors influencing the radiation exposure of man presented in scientific publication we have to deviate today from static equilibrium models. Such models can no longer satisfy at the present state of the art. The viewing of the short-term time behaviour of the radioecological parameter that is imperative with iodine-131 shows that the conventional calculation, chiefly with mean values of many years, does not satisfy the requirements to replace the calculation of the radiation exposure at the most unfavourable points of exposure demanded by the Radiation Protection Ordinance. This report proves that in a number of possible events under normal operating conditions the radiation exposure is far more important and the limiting dose rates are unmistakably exceeded. If favourable conditions coincide it can in fact be expected that the radiation exposure by radio iodine remains below the limiting close rate.

  11. A comparison between the secretion of Tc-99m pertechnetate and I-131 iodide through the stomach of the chacma monkey

    Ellmann, A.

    1985-03-01

    The way in which pertechnetate is excreted by the stomach is a continuing controversy in the nuclear medicine literature. The question arises: Does the stomach, unlike the thyroid handle pertechnetate and iodide by different mechanisms? The excretion of pertechnetate and iodide by the stomach in the Chacma baboon was compared. In this way an attempt was made to obtain more information on the way in which the stomach handles pertechnetate. The study was performed on young adult Chacma baboons. Pertechnetate and iodide were administeed simultaneously via the intravenous route. 6 Baboons were studied after pharmacological interventions, namely the administration of pentagastrin, cimetidine and perchlorate. Nine other baboons were studied after surgical interventions. Three groups of 3 each were studied after selective vagotomy, Billroth I gastrectomy and proximal gastrectomy respectively. In the surgical group post-operative studies were also done before and after pentagastrin stimulation. Tissue samples of the stomachs of 4 baboons were studied. The various types of surgery all resulted in a decrease in the volume of gastric juice. The excretion of pertechnetate and iodide was related to the volume of gastric juice except after the administration of perchlorate. In spite of marked changes of up to 60 times in the amount of pertechnetate and iodide excretion after the pharmacological and surgical interventions, the Tc : I - ratio remained almost constant. The Tc : I - ratio in the blood samples showed a gradual increase as could be expected. The Tc : I - ratios in the tissue samples were similar to those in the blood samples. It is indicated that, like iodide, pertechnetrat is probably excreted by the mucus cells of the stomach and not by the parietal cells. 28 figs., 164 refs., 6 tabs

  12. Low Dose I-131 MIBG therapy as an adjunct for bone pain palliation in pediatric patients with end-stage neuroblastoma: a pilot study

    Pascual, Thomas; Herbert, Anthony; Howman-Giles, Robert

    2009-01-01

    Full text: Objective: This study describes the initial experience in the use of low-dose 1-131 MIBG in patients with metastaticl refractory Neuroblastoma given at 18.5 Mbql Kg (0.5 mCi/Kg )to (1) achieve disease palliation (i.e., pain I symptom control) and improvement in the quality of life, through subjective response from patient/carers and (2) allow day-admission to minimize hospital stay providing more quality time between the patients and carers. Methods: Patients with refractory and metastatic Neuroblastoma whose primary treatment goal at that particular stage is pain palliation were given low-dose 1-131 M IBG at a dose of 18.5 Mbql Kg ( 0.5 mCil Kg)l. Assessment of subjective pain relief following 1-131 MIBG was done through interviews from hospital visits of the patient and home visits by the team. Results: Four patients underwent Low-Dose 1-131 MIBG Therapy for pain palliation between May 2007- March 2008. Median age was 5.75 years old and median total dose given was 539 Mbql patient (14.5 mCil patient). All patients at a cenain time had relief from disease pain allowing them to communicate with family and participate in physical activities not priyiledged before. Observations gathered from carersl parents revealed that the overall quality-of-life improved after the 1-131 MIBG therapy with concurrent pain medication protocol. Conclusion: This initial I pilot study described achievement of disease palliation (i.e., pain and symptom control) and improvement in the quality of life of Stage IV Neuroblastoma patients and allows day-admissions providing more quality time between the patient and the family and reduces patient anxiety.

  13. Iterative stimulation of endogenous TSH for ablation. Followup and/or treatment with I-131 in patients with differentiated thyroid carcinoma

    Degrossi, Osvaldo J.; Garcia del Rio, Hernan; Alvarez, L.; Pena, M.; Faure, E.

    2006-01-01

    In patients with differentiated thyroid carcinoma it is indispensable to raise the values of TSH to determine thyroglobulin and to effect the total tracking with radioiodine. Traditionally to raise the endogenous TSH it is necessary to suspend the opotherapy during a prolonged time with the consistent hypothyroidism. The objective of this work is to increase the endogenous TSH, shortening the time of abstinence of opotherapy [es

  14. Measurement of the Dose to the Family Members Taking Care of Thyroid Cancer Patients Undergoing I-131 Therapy in Nuclear Medicine Using TLD-100.

    Zehtabian, M; Dehghan, N; Danaei Ghazanfarkhani, M; Haghighatafshar, M; Sina, S

    2017-05-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commitions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. The Chernobyl I-131 Release: Model Validation and Assessment of the Countermeasure Effectiveness. Report of the Chernobyl 131I Release Working Group of EMRAS Theme 1

    2012-01-01

    The Chernobyl 131 I Release Working Group (IWG) which was established within the framework of the EMRAS Programme continues some of the more traditional work of previous international programmes that were aimed at increasing confidence in methods and models for the assessment of radiation exposure related to the environmental releases. There is still very little information regarding the quantitative relationship between radiation dose to the thyroid from Chernobyl and the risk of thyroid cancer. The uncertainty combined with individual estimates of radiation dose constitutes a crucial point in establishing this relationship, since, any release of radioiodine into environment creates wide range of uncertainty for internal dose assessments. The 131 I scenarios provide an excellent opportunity to compare a number of modelling approaches to a single assessment problem, in a dose reconstruction context. Nine experts in environmental modelling participated in the Plavsk Scenario dealing with areas of assessment modelling for which the capabilities are not yet well established. One could observes the remarkably improvement in models performance comparing with previous radioiodine scenarios. Predictions of the various models were within a factor of three of the observations, discrepancies between the estimates of average doses to thyroid produced by most participant not exceeded a factor of ten. The process of testing independent model calculations against independent data set also provided useful information to the originators of the test data.

  16. The study of transit time measurement for flow through the central and southern canals of MADA using I-131 radioisotope technique

    Roslan Mohd Ali; Md Shahid Ayub; Zainuddin Othman; Juhari Yusof; Mohd Asri Ramli; Eow Boon Tiak

    1996-01-01

    The measurement of breakthrough and transit time through the central and southern canals of Lembaga Kemajuan Pertanian Muda (MADA) by using radiotracer technique is discussed An estimated of 1700 cusec water was released from Pelubang regulator through central canal. The water is then distributed through several regulators down stream and finally ended through the SCD1 and SCD1a secondary canals. Radiotracer 1-131 with the activity of 250 mCi and 500 mCi were injected at several identified injection points by using glass breaker technique. The measurement of breakthrough and transit time were observed respectively at several measurement station. Results of the study indicated that the time travel from Pelubang regulator to SCD1a secondary canal would take about 3 days during normal operation. Detail of breakthrough and transit time at every regulators and other measurement stations were also presented

  17. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by "1"3"1I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  18. Investigation of the yearly dynamics of the intensity of reciprocal feeding among honey bees Apis mellifica L. by means of I131

    Skirkevicius, A.V.; Bagdonas, J.-S.A.

    1978-01-01

    The results of the investigation show that the early change of the intensity of reciprocal feeding among honey bees makes up a circle consisting of 4 phases, 2 of them being with a more frequent and 2 with a less frequent reciprocal feeding. The duration of one phase varies from 1 to 6 months. The intensity of the reciprocal feeding is the same during both phases with the less frequent reciprocal feeding, while significantly unequal in the phases with the more frequent reciprocal feeding (on the average by 2.6 times greater in the 2nd phase than in the 4th). There is a positive correlation between the yearly dynamics of the intensity of reciprocal feeding and the quantity of feed given by the nurse bee. The average radioactivity per 1 bee (from those who got radioactive feed) is constant and depends neither upon season nor the period worker bees were kept in the group. Here is a positive correlation between the yearly dynamics of the intensity of reciprocal feeding among worker bees and the extent of variability of the quantity of feed they receive

  19. Protocol of specific health monitoring: ionizing radiation, 11 years later; Protocolo de vigilancia sanitaria especifica: radiaciones ionizantes, 11 anos despues

    Castillejo Puertas, F. M.

    2016-08-01

    Since the approval on November 11{sup t}h 2003 of the Protocol of Specific Health Monitoring for Workers Exposed to Ionizing Radiation a study has been carried out to discover its effectiveness. These areas were examined: the daily practice od accupational medicine and, in particular, its specific task in the application of the different clinical/labour criteria for workers exposed to ionizing radiation or at risk of radioactive contamination; the degree of its uses as well as the updates and improvements. For that purpose, a descriptive bibliographic revision has been used for the last 11 years. The results revealed the lack of updates of the Protocol as well as the few usable objective criteria, when the clinical/labour aptitudes are reflected upon. (Author)

  20. Constituição da alexina e mechanismo da hemolyse especifica Constitution of alexin and mechanism of specific haemolysis

    J. da Costa Cruz

    1932-08-01

    Full Text Available Os autores observam que após a inactivação de sôro de cobaya a 54° durante 30 minutos permanecem no sôro as fracções thermolabeis em quantidade apreciavel; um tal sôro conservado na temperatura de 6°, por espaço de 18 horas, regenera parte da sua actividade alexica perdida. 2° Confirma-se a existencia de 4 componentes do complemento. 3° O chamado terceiro componente de Ritz e Coca é na verdade constituidos por dois elementos, pelos menos, differentes: um destructivel pelo formol e outro destructivel pelo hydrosulphito de sodio. 4° A ammonia, o formol e o hydrosulpito de sodio são capazes de destruir os constituintes thermoresistentes da alexina do sôro inactivado a 56° 30 minutos, ao passo que as emulsões de levedos, de orgãos ou de gelose não o são. 5° As emulsões de levedo addicionadas a uma mistura em partes eguaes de sôro fresco de cobaya e de sôro aquecido a 56°, 30 m., são capazes de retirar não só o terceiro componente contido no sôro fresco da mistura, mas tambem o terceiro componente contido no sôro inactivado pelo calor. 6° Sem excluir a hypothese de uma floculação em que o sôro aquecido exerça o papel de um colloide protector, os autores admittem que a inactivação do complemento pelas emulsões de levedo ou pela gelose seja devida a substancias thermolabeis, do sôro, depois de adsorpção por essas emulsões, de substancias anti-tripticas. 7° Os diversos elementos que constituem a alexina são adsorvidos pelos globulos sensibilizados na seguinte ordem: Globulos-sensibilizadora-Fracção thermo-resistente sensivel á ammonia-Fracção thermolabil Globulina-Fracção thermolabil albumina-Fracção thermoresistente sensivel ao formol-Fracção thermoresistente sensivel ao hydrosulphito de sodio. 8° Na reacção de Bordet-Wassermann fortemente positiva é fixada sobretudo a fracção globulina thermolabil do complemento e não sómente o terceiro componente como seria licito esperar; a fracção thermolabil albumina permanece de regra livre e activa no liquido. 9° Os autores acham que se deve considerar como demonstrada a origem hepatica da alexina. Segundo experiencias procedidas em cães intoxicados pelo chloroformio não só baixa consideravelmente o titulo alexico global do sôro mas tambem os titulos, de todos os constituintes da alexina separadamente, soffrem, com a excepção da fracção thermolabil globulina, uma reducção muito accentuada.1 The writers state that after the inactivation of fresh Guinea pig'serum at 54°C, for 30 minutes, this serum keeps the thermolable fractions in noticeable quantities. Such serum if mantained at 6°C. for 18 hours, reacquires part of the lost alexic activity. 2 The Ritz's, and Coca's 3rd component is formed at least by distinct elements, one sensible to tje action of formaline and the other to the action of sodium hydrosulphite. 4 Ammonia, formaline and sodium hydrosulphite are able to destroy the thermostable components of the serum inactivated by heat (56°C., 30 minutes. The emulsions of yeast, organs and gelose are not able to do so. 5 The yeats emulsions added to a mixture o equal parts of G. p. fresh serum and serum inactivated by heat are capable to destroy the 3rd component present not only in the fresh serum as also in the inactivated one. 6 The writers do not exclude the hypothesis of a flocculation in which the inactivated serum exerts the rôle of a protector colloid, but they believe that the inactivation of the complement by yeast emulsions is due to the action of thermolable substances of fresh serum after the adsorption of antitriptic substances by said emulsions. 7 The different components which form the alexin adhere to the sensitized blood cells in the following order: Blood cells-sensitizer-Thermostable fraction sensible to ammonia -Thermolable globulin fraction - Thermolable albumin fraction - Thermostable fraction sensible to formaline and thermostable fraction sensible to sodium hydrosulphite. 8 In the Bordet-Wassermann's reaction, stark positive, is fixated especially the thermolable globulin fraction and not only the 3rd component as it could be supposed. The thermolable albumin fraction remains free and active in the fluid. 9 The writers think that the hepatic origin of the alexin must be accepted. According to experiments on dogs intoxicated by chloroform one observes not only the diminution of the alexic activity but also the decrease of all components of the alexin, with, perhaps, the exception of the thermolable globulin fraction.

  1. Uma metodologia para especificação e síntese de unidades de controlo reconfiguráveis

    Melo, Andreia Barbosa de

    2006-01-01

    Nesta tese toma-se um circuito digital estruturado de acordo com a comum divisão em unidade operacional (datapath) e unidade de controlo, e explora-se o projecto da unidade de controlo. Em concreto, explora-se o projecto de unidades de controlo complexas, que incluam reentrância e paralelismo. Além disso, explora-se a possibilidade de utilização de estruturas reutilizáveis que possam implementar diferentes unidades de controlo. A construção de arquitecturas de implementação que suportem a res...

  2. Transport of uranium concentrates: low specific activity versus logistic complexity; Transporte de concentrado de uranio: baixa atividade especifica versus complexidade logistica

    Dias, Pedro L.S.; Macedo, Eclesio F; Carvalho, Leonardo B; Carvalho, Renata R., E-mail: pedroluis@inb.gov.b, E-mail: eclesio@inb.gov.b, E-mail: leonardobernadino@inb.gov.b, E-mail: renatarangel@inb.gov.b [Industrias Nucleares do Brasil S.A., Caetite, BA (Brazil)

    2011-10-26

    This paper describes the case of radioactive material transport, according to pertinent documentation - nuclear material specifically in the form op ammonium diuranate, produced by Industrias Nucleares do Brasil S.A. - from the mine and physic-chemical processing at Caetite, Bahia, to the port of Salvador, state of Bahia, approaching the radiological protection aspects

  3. Deterministic Safety Analysis for Nuclear Power Plants. Specific Safety Guide (Spanish Edition); Analisis determinista de seguridad para centrales nucleares. Guia de Seguridad Especifica

    NONE

    2012-12-15

    The IAEA's Statute authorizes the Agency to establish safety standards to protect health and minimize danger to life and property - standards which the IAEA must use in its own operations, and which a State can apply by means of its regulatory provisions for nuclear and radiation safety. A comprehensive body of safety standards under regular review, together with the IAEA's assistance in their application, has become a key element in a global safety regime. In the mid-1990s, a major overhaul of the IAEA's safety standards programme was initiated, with a revised oversight committee structure and a systematic approach to updating the entire corpus of standards. The new standards that have resulted are of a high calibre and reflect best practices in Member States. With the assistance of the Commission on Safety Standards, the IAEA is working to promote the global acceptance and use of its safety standards. Safety standards are only effective, however, if they are properly applied in practice. The IAEA's safety services - which range in scope from engineering safety, operational safety, and radiation, transport and waste safety to regulatory matters and safety culture in organizations - assist Member States in applying the standards and appraise their effectiveness. These safety services enable valuable insights to be shared and I continue to urge all Member States to make use of them. Regulating nuclear and radiation safety is a national responsibility, and many Member States have decided to adopt the IAEA's safety standards for use in their national regulations. For the contracting parties to the various international safety conventions, IAEA standards provide a consistent, reliable means of ensuring the effective fulfilment of obligations under the conventions. The standards are also applied by designers, manufacturers and operators around the world to enhance nuclear and radiation safety in power generation, medicine, industry, agriculture, research and education. The IAEA takes seriously the enduring challenge for users and regulators everywhere: that of ensuring a high level of safety in the use of nuclear materials and radiation sources around the world. Their continuing utilization for the benefit of humankind must be managed in a safe manner, and the IAEA safety standards are designed to facilitate the achievement of that goal.

  4. LA CALIDAD DE SERVICIO: UNIDIMENSIONALIDAD VS. MULTIDIMENSIONALIDAD (UNA ESCALA ESPECIFICA PARA EL SECTOR DE BANCA COMERCIAL [doi: 10.5329/RECADM.20040302012

    José Maria Santiago Merino

    2004-11-01

    Full Text Available Normal 0 21 false false false PT-BR X-NONE X-NONE MicrosoftInternetExplorer4 RESUMO Esta pesquisa pretende iluminar a controvérsia suscitada entre os dois principais enfoque ou paradigmas da medição da Qualidade do Serviço (Parasuraman, Zeithml y Berry –Cronin y Taylor, propondo uma  escala diferente de medição do construto para o setor da banca comercial, conseqüência da replicação “ex novo” da investigação do PZB, com um enfoque de convergência ou triangulação metodológica e de técnicas de análise. Confrontam-se os dois modelos dominantes numa tentativa de confirmação/refutação do jeito de operacionalizar o construto “qualidade do serviço” em cada um deles, assim como da unidimensionalidade do mesmo perante a multidimensionalidade. Do mesmo modo supõe o desenvolvimento das indicações dos referidos pesquisadores para incrementar o domínio dos conteúdos da qualidade do serviço aos produtos/serviços, preços e imagem das entidades, e analisar com maior profundidade as relações da qualidade com a satisfação e com a lealdade, procurando melhores preditores da ultima com a integração de aspectos atitudinais e comportamentais na sua operatividade. Palavras-chave:Qualidade do Serviço, Escalas de medição, Banca.     RESUMEN El presente artículo pretende arrojar luz sobre la controversia suscitada entre los dos principales enfoques o paradigmas de medición de la Calidad de Servicio (Parasuraman, Zeithaml y Berry - Cronin y Taylor, proponiendo una diferente escala de medida del constructo para el sector de banca comercial, fruto de la replicación "ex novo" de la investigación de PZB, con un enfoque de convergencia o triangulación metodológica y de técnicas de análisis. Se enfrentan los dos modelos dominantes en un intento de confirmación/refutación de la forma de operacionalizar el constructo "calidad de servicio" en cada uno de ellas, así como de la unidimensionalidad del mismo frente a la multidimensionalidad. Supone, asimismo, el desarrollo de las sugerencias de los citados investigadores en el sentido de ampliar el domino de los contenidos de la calidad de servicio a los productos/servicios, precio e imagen de las entidades, y de analizar con mayor profundidad las relaciones de la calidad con la satisfacción y con la lealtad, buscando mejores predictores de la última con la integración de aspectos actitudinales y comportamentales en su operativización. Entre los principales resultados destaca la falta de adecuación del modelo explicativo de la calidad de servicios basado en las divergencias, siendo la forma de opracionalización del constructo que mejor se ajusta a los datos aquella que se basa sólo en la percepción del desempeño, cuyos resultados obtienen mejor ajuste, fiabilidad y validez tanto convergente como predictiva. Respecto a la estructura dimensional se confirma la multidimensionalidad del constructo, abogando por una estructura compleja superior a los 25 factores, que en la práctica implica su reducción a una sola (magnitud escalar que puede ser expresada en un índice de calidad, lo que facilita su utilización en el proceso de toma de decisiones. Palabras clave: Calidad de Servicio, Escalas de Medida, Banca

  5. Trocas emocionais na díade mãe-filhos com perturbação especifica da linguagem: estudo preliminar

    Costa Brás, Diana Patrícia

    2016-01-01

    Neste estudo, procurou-se investigar as trocas emocionais e a influência da qualidade da relação e da responsividade materna no desenvolvimento emocional de crianças em idade pré-escolar com Perturbação Específica da Linguagem (PEL), comparando-as com crianças sem perturbação da linguagem. N/A

  6. Acções phylacticas não especificas em relação aos venenos ophidicos: tratamento auxiliar dos accidentes ophidicos

    J. Vellard

    1929-01-01

    Full Text Available Dans l'intoxication expérimentale du pigeon avec les venins de Crotalus terrificus, de Lachesis jararaca et de Naya tripudians, nous avons étudié l'action de 12 médicaments, possédant des affinités neurotropes plus ou moins accusées, arrivant aux conclusions suivantes: 1 - Quelques-uns des ces médicaments exercent une action protectrice spéciale contre ces venins, permettant, injectés une heure avant le vénin, d'eviter tout symptôme d'intoxication chez le pigeon. Certains n'agissent qu'injectés em même temps que le vénin. D'autres sont complètement inactifs. Aucun d'êntre eux ne possède de propriétés curatives. 2 - En plus de ce pouvoir protecteur, ou phylactique, un certain nombre d'entre eux possède sur les venins, une action neutralisante "in vitro", s'accentuant après une heure de contact. 3 - Les conditions dans lesquelles s'exercent ces deux actions, protectrice et neutralisante, sont très variables suivant les venins et les médicaments. Sur leur mécanisme très complexe, on ne peut actuellement formuler que des hypothèses. 4 - Au point de vue pratique, certains de ces médicaments, surtout la spartéine et l'adrénaline, peuvent être utilisés avec avantage comme complément du traitement sérotérapique spécifique dans les accidents déterminés par les animaux venimeux.

  7. The Development of Strategies for the Assignment of Semantic Information to Unknown Lexemes in Text. Lenguas para Objetivos Especificas (Languages for Special Purposes), No. 5.

    Alderson, Charles; Alvarez, Guadalupe

    An English for Special Purposes (ESP) course being developed aims to give the students a series of techniques to help them handle vocabulary in a text, and teach them strategies for identifying meaning in context. Traditional strategies, such as the study of morphology, use of grammatical information, and exercises in dictionary usage, are…

  8. Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias

    Gonzalez Z, M A [Departamento de Medicina Nuclear, Instituto Nacional de Pediatria (Mexico); Ferro F, G [Departamento de Materiales Radiactivos, Instituto nacional de Investigaciones Nucleares, Salazar, Estado de Mexico C.P. 52045 (Mexico); Rivera M, T; Azorin N, J [Departamento de Fisica, UAM Iztapalapa, Mexico D.F. (Mexico)

    1999-07-01

    It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

  9. Implementation of an alanine dosimetry service; Puesta en marcha de un servicio de dosimetria de alanima

    Gago Arias, A.; Nunez Pelaez, N.; Peteiro Vilaseco, E.; Gomez Rodriguez, F.; Gonzalez Castano, D. M.

    2011-07-01

    This work facing the implementation of an alanine dosimetry service, linked to the installation of Co{sub 6}0 Radio physics Laboratory (LP) and Paramagnetic Resonance Service of the University of Santiago de Compostela (USC).

  10. Update Dosimetry Service internal staff Tecnatom; Actualizacion del servicio de dosimetria personal interna de TECNATOM

    Bravo, B.; Marchena, P.; Alonso, A.; Navarro, E.; Serrano, E.

    2010-07-01

    The beginning of decommissioning of nuclear facilities and other industrial national context conditions have been a very significant increase in the need for such services, which have been almost overwhelmed by the demand. To provide a solution to this situation, Tecnatom decided to run as a new internal dosimetry service indirect measures to complement its renowned capabilities of direct measures. To perform this task, Tecnatom has signed a collaboration agreement with the Laboratory of Radiochemistry of Geocisa, all with the objective of characterizing contamination by alpha emitters or beta different analytical techniques.

  11. Calibration curves for biological dosimetry; Curvas de calibracion para dosimetria biologica

    Guerrero C, C.; Brena V, M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail cgc@nuclear.inin.mx

    2004-07-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of {sup 60} Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  12. State of the art of solid state dosimetry; Estado da arte em dosimetria do estado solido

    Souza, Susana O., E-mail: sosouza@ufs.br [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Yamamoto, Takayoshi [Radioisotope Research Center, Osaka University (Japan); D' Errico, Francesco, E-mail: francesco.derrico@yale.edu [Yale University, School of Medicine, CT (United States)

    2014-07-01

    Passive solid-state detectors still dominate the personal dosimetry field. This article provides state of the art in this field and summarizes the most recent works presented on TL, OSL and RPL during the 17th International Conference on Solid State Dosimetry held in Recife in September 2013. The Article contains in particular the techniques Thermoluminescence (TL), Optically Stimulated Luminescence (OSL), radio photoluminescence (RPL). Thermoluminescence has the biggest advantage of the wide availability of commercial materials for dosimetry, and the nature tissue-equivalent of several of these materials. The limitation of the TL dosimetry presents fading luminance signal and the need for high temperatures to obtain the signal. The Optically Stimulated Luminescence has the advantages of high sensitivity, the possibility of multiple reading, while its limit is the need to use response compensating filters in addition to the high cost of equipment and dosimeters still restricted very few options trading . The radio photoluminescence has a reading that is completely non-destructive, but their dosimeters present lack of tissue-equivalent and a high cost. Presents the details of the techniques and the advantages and limitations of each of these will be discussed.

  13. Design of a system for neutrons dosimetry; Diseno de un sistema para dosimetria de neutrones

    Ceron, P.; Rivera, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Sanchez, A. [IPN, Escuela Superior de Fisica y Matematicas, Av. Instituto Politecnico Nacional s/n, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico); Vega C, H. R., E-mail: victceronr@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-08-15

    At the present time diverse systems of detection of neutrons exist, as proportional counters based on BF{sub 3}, He{sub 3} and spectrometers of Bonner spheres. However, the cost and the complexity of the implementation of these systems put them far from the reach for dosimetric purposes. For these reasons a system of neutrons detection composed by a medium paraffin moderator that forms a 4π (spheres) arrangement and of several couples of thermoluminescent dosimeters TLD 600/TLD 700. The response of the system presents a minor repeatability to 5% in several assays when being irradiated with a {sup 239}PuBe source and a deviation of 13.8% in the Tl readings of four different spheres. The calibration factor of the system with regard to the neutrons source which was of 56.2 p Sv/nc also was calculated. These detectors will be used as passive monitors of photoneutrons in a radiotherapy room with lineal accelerator of high energy. (Author)

  14. Dosimetry with slow films in Interventional Radiology; Dosimetria con peliculas lentas en Radiologia Intervencionista

    Ten, J.I.; Guibelalde, E.; Fernandez, J.M.; Canevaro, L.; Ramirez, R.; Vano, E. [Grupo de Fisica Medica. Departamento de Radiologia. Facultad de Medicina. Universidad Complutense de Madrid. Martin Lagos s/n CP 28040, Madrid (Spain)

    1998-12-31

    In this work it is presented a method for evaluation of patients doses in Interventional Radiology (RI). The method proposed in this work allows the simultaneous valoration of the product dose-area (PDA), the dose in the patient skin (DES) and the distribution of the irradiated fields, all of they together with their corresponding dose levels. The latter sometimes can be essential since the possible damages in skin depend not only of the doses, but also the irradiated area. The method has been resulted adequate for to evaluate doses to patients in Interventional Radiology procedures. It was possible to apply it as a routine form seeing that its not interfering significantly in the normal development of the medical intervention. The fundamental advantages of this dosimetric method in relation with the unique PDA measure or with the utilization of TLD is that it provide information about the total irradiated area, distribution and length of fields, collimation and wedge used besides that allow to determine the most irradiated zone. The visualization of the irradiated regions and the length fields utilized suggest the possibility to optimize the realization protocols of the interventional procedure in the cases in which it is considered that the doses have been very elevated. (Author)

  15. Advances in electron dosimetry of irregular fields; Avances en dosimetria de electrones de campos irregulares

    Mendez V, J. [Departamento de Radioterapia, Instituto de Enfermedades Neoplasicas, Avenida Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    In this work it is presented an advance in Electron dosimetry of irregular fields for beams emitted by linear accelerators. At present diverse methods exist which are coming to apply in the Radiotherapy centers. In this work it is proposed a method for irregular fields dosimetry. It will be allow to calculate the dose rate absorbed required for evaluating the time for the treatment of cancer patients. Utilizing the results obtained by the dosimetric system, it has been possible to prove the validity of the method describe for 12 MeV energy and for square field 7.5 x 7.5 cm{sup 2} with percentile error less than 1 % . (Author)

  16. Thermoluminescent dosimetry in computed tomography for pediatric patients; Dosimetria termoluminiscente en tomografia computada para pacientes pediatricos

    Medrano S, A. C.; Medina A, O.; Hidalgo T, S.; Azorin N, J., E-mail: alicesar1993@hotmail.com [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2015-10-15

    Computed tomography (CT) in conjunction with interventional radiology, is considered as high-dose radiological procedure, so the optimization of the dose is necessary. Exposure to ionizing radiation in pediatric CT is of particular interest because the children are up to 10 times more sensitive to radiation than adults, the late somatic and genetic effects of radiation. The exposure and risk associated with ionizing radiation in CT is best characterized by the absorbed dose to each organ. Thermoluminescent dosimeters of LiF: Mg, Ti are best suited for this purpose due to its characteristics such as high sensitivity, small size and its equivalence with the tissue. The results of dose measurements -in vivo- to the three types of CT studies (skull, thorax and abdomen) are presented. These results indicate that lower doses were obtained in skull study, while the highest was one of abdomen. (Author)

  17. Dosimetry of ionizing radiations by Electron paramagnetic resonance; Dosimetria de radiaciones ionizantes por resonancia paramagnetica electronica

    Azorin N, J [UAM-I, Av. San Rafael Atlixco 186, 09340 Mexico D.F. (Mexico)

    2005-07-01

    In this work, some historical and theoretical aspects about the Electron Paramagnetic Resonance (EPR), its characteristics, the resonance detection, the paramagnetic species, the radiation effects on inorganic and organic materials, the diagrams of the instrumentation for the EPR detection, the performance of an EPR spectrometer, the coherence among EPR and dosimetry and, practical applications as well as in the food science there are presented. (Author)

  18. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  19. Thermoluminescent dosimetry in fluoroscopy of pediatric patients; Dosimetria termoluminiscente en fluoroscopia de pacientes pediatricos

    Garcia V, E.; Azorin N, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Departamento de Fisica, San Rafael Atlixco 186, Col. Vicentina, 09340 Ciudad de Mexico (Mexico); Hidalgo T, S.; Dies S, P., E-mail: azorin@xanum.uam.mx [Hospital Infantil de Mexico Federico Gomez, Dr. Marquez 162, Col. Doctores, 06720 Ciudad de Mexico (Mexico)

    2016-10-15

    The use of thermoluminescent dosimeters in the area of medical physics and especially in radiology is of paramount importance to guarantee the quality of a particular study, which for this reason the need to verify by means of measurements of peripheral dose in studies of esophagogastroduodenal series by fluoroscopy using TLD of LiF:Mg, Ti. For this the necessary measurements were carried out directly in patients of the Children s Hospital of Mexico Federico Gomez. Previously characterized the dosimeters were used the graphs of the linear equation to obtain the absorbed dose of each dosimeter and was found that the values of the absorbed dose in each patient changes for various reasons like the anatomy, thickness of the tissues, age and exposure time during the study and was verify that none of the studies performed on patients exceeded dose levels that could affect healthy organs. (Author)

  20. Internal dosimetry in nuclear medicine procedures; Dosimetria interna por procedimientos en medicina nuclear

    Carrera Magarino, F.; Salgado Garcia, C.; Ruiz Manzano, P.; Rivas Ballarin, M. A.; Jimenez Hefernan, A.; Sanchez Segovia, J.

    2011-07-01

    The Department of Radio Physics and Radiation Protection, University Hospital Lozano Blesa Zaragoza presented a calculus textbook to estimate patient doses in diagnostic nuclear medicine. In this paper present an updated version referred Book of calculation.

  1. Course on internal dosimetry in nuclear medicine; Curso de dosimetria interna en medicina nuclear

    NONE

    2004-07-01

    This documentation was distributed to the participants in the Course of Internal Dosimetry in Nuclear Medicine organised by the Nuclear Regulatory Authority (ARN) of Argentina and held in Buenos Aires, Argentina, August 9-13, 2004. The course was intended for people from IAEA Member States in the Latin American and Caribbean region, and for professionals and workers in medicine, related with the radiation protection. Spanish and English were the languages of the course. The following subjects were covered: radioprotection of the patient in nuclear medicine; injuries by ionizing radiations; MIRD methodology; radiation dose assessment in nuclear medicine; small scale and microdosimetry; bone and marrow dose modelling; medical internal dose calculations; SPECT and image reconstruction; principles of the gamma camera; scattering and attenuation correction in SPECT; tomography in nuclear medicine.

  2. Personnel thermoluminescent dosimetry of plane pilots; Dosimetria personal termoluminiscente de pilotos aviadores

    Azorin V, J.C. [Universidad Nacional Autonoma de Mexico, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Rivera M, T. [Universidad Autonoma Metropolitana Iztapalapa, Departamento de Fisica, 09340 Mexico D.F. (Mexico); Azorin N, J. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, 11500 Mexico D.F. (Mexico)

    1999-07-01

    In this work are presented the results of the research realized in the pilots of commercial planes of the different flight equipment existing. The results obtained show that the pilots receive during their work, doses of ionizing radiation greater than the limit recommended by the International Commission of Radiological Protection. (Author)

  3. Retrospective dosimetry of nail by Electron Paramagnetic Resonance; Dosimetria retrospectiva de unha por Ressonancia Paramagnetica Eletronica

    Giannoni, Ricardo A., E-mail: giannoni@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rodrigues Junior, Orlando, E-mail: rodrijr@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The purpose of this study is to characterize samples of human nails, subjected to irradiation of high doses through Technical Electron Paramagnetic Resonance (EPR). The goal is to establish a dose/response relationship in order to assess dose levels absorbed by individuals exposed in radiation accidents situations, retrospectively. Samples of human nails were irradiated with gamma radiation, and received a dose of 20 Gy. EPR measurements performed on samples before irradiation identified EPR signals associated with defects caused by the mechanical action of the sample collection. After irradiation other species of free radicals, associated with the action of gamma radiation, have been identified.

  4. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  5. Answer to request on the ININ internal dosimetry; Respuesta a encuesta sobre dosimetria interna del ININ

    Alfaro L, M.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1999-05-15

    In this report it is presented the reply to CNSNS asking for information about the methodology for the evaluation of the occupational dose due to internal contamination. The characteristics of the installation, type and dimensions of the shield room, construction materials, type of detecting, calibration geometries, type of used phantom, intervals of energy of the calibration, type of routine measurements, detection limit for Cs-137 and Co-60, code to carry out the analysis of the spectra, evaluation of the measurement data, whole body system type armchair with anthropomorphic phantom, whole body system of vertical scanning, distribution and location diagram of the internal dosimetry laboratory there are among the treated aspects. (Author.

  6. Dosimetry of a Cesium 137 source; Dosimetria de una fuente de Cesio 137

    Torres R, J.G.; Manzanares A, E.; Vega C, H.R. [Unidades Academicas de Estudios Nucleares, Universidad de Zacatecas (Mexico)

    2005-07-01

    It was carried out a dosimetric study of a source of Cesium 137 used in investigations of Radiobiology. This radionuclide has a half life of 30.07 years and it emits photons of 661.657 keV with a probability of 85.2%. The source has been used in a series of experiments trending to observe the cellular response before the gamma rays, as well as for the calibration of equipment of radiological protection. For such reason it is important to determine the dosimetric properties. In this work it was determined the absorbed dose that this source takes when being placed in the center from a methylmethacrylate badge to three distances, 5, 10 and 15 cm. The dose was measured with thermoluminescent dosemeters and it was calculated by means of Monte Carlo method, also was derived an expression that allows to determine the dose starting from the information of the activity of the source and of the distance regarding the same one. (Author)

  7. Experimental determination of the transfer functions feed/beaf, feed/pork, feed/milk for Cs-137, Co-60, Mu-54, Na-22, I-131, and Tc-95m

    Voigt, G.; Henrichs, K.; Proehl, G.; Paretzke, H.G.

    1986-05-01

    After the Chernobyl reactor accident, experimental studies have been made with a group of animals, and the results measured are presented in tabular form. The transfer factors of Na-22 have been found to be affected by the daily amount of stable sodium content in the feed. Mn-54 quantities in the feed have been too low to be measured. For two different feeding modes, equilibrium transfer factors of Co and Cs have been determined in pork. As to cereals and potatoe diets, upper limits of transfer have been found. The data obtained for the transfer factor of iodine to milk are in good agreement with published data. (DG) [de

  8. Improvement of dosimetry for I-131 therapy of lung metastases with special regard to children with thyroid cancer from Belarus following the Chernobyl accident. Final report 1997-1999

    Lassmann, M.; Reiners, C.; Allen, S.

    2000-01-01

    The main problem in treating disseminated pulmonary metastases in children with papillary thyroid cancer is to find a balance between an insufficient dose for the ablation of metastatic tissue and unnecessary high radiation exposure to the lungs and the bone marrow. This can hardly be achieved without quantitative dosimetry for the more or less inhomogeneously distributed 1-131 in high dosed radioiodine therapy. The major goal of this project is to improve the concept for treating patients with lung metastases induced by thyroid carcinoma. Almost all of the patients with lung metastases are treated in more than one therapy course. After each course the knowledge of the doses to the tumor tissue, the lung, and the bone marrow is of crucial importance for a well funded decision about further treatment. In the cases of either the tumor doses being inefficient for ablation or substantial impairment of residuing pulmonary metastases or the cumulated doses to lung and bone marrow exceeds empirically defined ''critical'' limits the fractionated radioiodine treatment has to be stopped to avoid side effects such as lung fibrosis or leukemia in patients with papillary thyroid cancer. The decision which has to be taken must consider that prognosis with respect to mortality and quality of life even in the case of persisting lung metastases may be better than after the induction of progressive pulmonary fibrosis. Up to now, patients are treated more or less empirically until complete remission is achieved and no tumor uptake is visible in post-therapeutic scans with a gamma camera or the cumulative activity of 1-131 taken up by the lungs exceeds 3 GBq (80 mCi) according to recommendations given by Benua and Leaper in 1962. This project combines empirical approaches with theoretical research at cellular level to optimize the dose to the tumor cells with protection of healthy lung tissue. (orig.)

  9. Summary report: BIOMOVS Chernobyl scenarios A4 (multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain) and A5 (dynamics within lake ecosystems)

    Peterson, S-R

    1993-05-01

    To assess dose, many data on the concentrations of radionuclides (particularly {sup 131I} and {sup 137C}s) in various foods were collected world-wide in the days, months and years following the accident at the Chernobyl Nuclear Power Plant in 1986. These data, combined with measurements of air concentrations taken during the passage of the plume, and with other measurements of radioactivity in the environment, have been used to test time-integrated and time-dependent predictions of agricultural and aquatic food-chain models. This report reviews two such model validation exercises, one of which examined the air-forage (or grain)-milk/beef pathways, while the other modelled the deposition-water-sediment/fish pathways. Time-dependent results were studied to determine which processes were important. In the aquatic exercise an initial fast transfer to the sediments was identified that had not been accounted for in the models. Parameter values used commonly in models were reassessed in the light of model performance. It was recommended that the transfer factor from feed to milk (F{sub m}) for {sup 131I} be reduced based on new information. Uncertainties about the model predictions were considered. (author). 9 refs., 4 tabs., 3 figs.

  10. Summary report: BIOMOVS Chernobyl scenarios A4 (multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain) and A5 (dynamics within lake ecosystems)

    Peterson, S-R.

    1993-05-01

    To assess dose, many data on the concentrations of radionuclides (particularly 131I and 137C s) in various foods were collected world-wide in the days, months and years following the accident at the Chernobyl Nuclear Power Plant in 1986. These data, combined with measurements of air concentrations taken during the passage of the plume, and with other measurements of radioactivity in the environment, have been used to test time-integrated and time-dependent predictions of agricultural and aquatic food-chain models. This report reviews two such model validation exercises, one of which examined the air-forage (or grain)-milk/beef pathways, while the other modelled the deposition-water-sediment/fish pathways. Time-dependent results were studied to determine which processes were important. In the aquatic exercise an initial fast transfer to the sediments was identified that had not been accounted for in the models. Parameter values used commonly in models were reassessed in the light of model performance. It was recommended that the transfer factor from feed to milk (F m ) for 131I be reduced based on new information. Uncertainties about the model predictions were considered. (author). 9 refs., 4 tabs., 3 figs

  11. The electrophilic lodi nation with 125 I/ 131 I of gamma globulin: Comparison between a solid-phase oxidizing agent (Iodogen), chloramine-T, iodine mono chloride and N-Bromo succinimide

    El-Wetery, A.S.; Ayyoub, S.; El-Mohty, A.A.; Raieh, M.; Ghonaim, A.Kh.

    1997-01-01

    A new available oxidizing agent, 1, 3, 4, 6-tetra chloro-3α, diphenyl glycoluril(iodogen) was compared with chloramine-T (Ch-T), Iodine-mono chloride (I Cl) and N-Bromo succinimide (NBS) in the radio-iodination of gamma-globulin (γ-G) with 'no-carrier-added' (nca) Na 131 I (T 1/2=8 d). In Phosphate and acetate buffer solution, the optimum reaction conditions with respect to PH, concentration of oxidizing agent, reaction time and concentration of γ-G were determined. The optimum conditions which were found require 100μ l of buffer (pH 7.4, 0.025 M), 500μg γ-G (0.003 μmol), (10-40) μg of oxidizing agent and the desired amount of carrier-free radioiodine. Highest radiochemical yield (>85-90%) were obtained at pH 7.4. Separation and identification of the labelled products were achieved by means of high performance liquid chromatography (HPLC) and thin layer chromatography (TLC). 8 figs., 1 tab

  12. Iodine I 131 Monoclonal Antibody BC8, Fludarabine Phosphate, Cyclophosphamide, Total-Body Irradiation and Donor Bone Marrow Transplant in Treating Patients With Advanced Acute Myeloid Leukemia, Acute Lymphoblastic Leukemia, or High-Risk Myelodysplastic Syndrome

    2018-05-14

    Acute Myeloid Leukemia Arising From Previous Myelodysplastic Syndrome; Adult Acute Lymphoblastic Leukemia in Remission; Adult Acute Myeloid Leukemia in Remission; CD45-Positive Neoplastic Cells Present; Chronic Myelomonocytic Leukemia; Previously Treated Myelodysplastic Syndrome; Refractory Anemia With Excess Blasts; Refractory Anemia With Ring Sideroblasts; Refractory Cytopenia With Multilineage Dysplasia; Refractory Cytopenia With Multilineage Dysplasia and Ring Sideroblasts

  13. Performance evaluation of of caesium, iodine, strontium and ruthenium isotopes in urban areas after contamination by accidental release

    Vetere, Maria Ines de Carvalho

    2002-03-01

    The exposures of urban populations to the radiation derived from the deposition, after accidental atmospheric releases, of I37 Cs, 134 Cs, 129 I, 131 I, 133 I, 89 Sr, l03 Ru and 106 Ru were assessed, using the integrated system for the evaluation of environmental radiological impact in emergency situations (SIEM), developed by the Instituto de Radioprotecao e Dosimetria (IRD) / Comissao Nacional de Energia Nuclear (CNEN). These radionuclides are fission products likely to be emitted in the occurrence of severe nuclear reactor accidents. Their environmental behaviour in urban areas, due to their deposition in soil, in urban surfaces and in vegetable-garden food products, such as leafy and non-leafy vegetables, were analyzed, and dose assessments at the short, medium and long terms were performed, with and without the application of protective measures for reduction of doses. Simulations of unitary initial deposition for each radionuclide and of two different potential accidents involving pressurized water reactors (PWR), with different source terms and distinct deposition for each radionuclide, were performed. Results were analyzed on the basis of the relative relevance of radionuclides and pathways for the exposure of members of the public, as a function of age and time after the release. It was also performed an assessment of the effectiveness of protective measures as a function of the moment of their implementation. (author)

  14. Assessment of Cesium, Iodine, Strontium and Ruthenium isotopes behaviour in urban areas, after contamination from accidental release

    Vetere, Maria Ines de Carvalho

    2002-01-01

    The exposures of urban populations to the radiation derived from the deposition, after accidental atmospheric releases, of 137 Cs, 134 Cs, 129 I, 131 I, 133 I, 89 Sr, 103 Ru and 106 Ru were assessed, using the integrated system for the evaluation of environmental radiological impact in emergency situations, developed by the Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear (CNEN). These radionuclide are fission products likely to be emitted in the occurrence of severe nuclear reactor accidents. Their environmental behaviour in urban areas, due to their deposition in soil, in urban surfaces and in vegetable-garden food products, such as leafy and non-leafy vegetables, were analyzed, and dose assessments at the short, medium and long terms were performed, with an without the application of protective measures for reduction of doses. Simulations of unitary initial deposition for each radionuclide and of two different potential accidents involving water reactors (PWR), with different source terms and distinct deposition for each radionuclide, were performed. Results were analyzed on the basis of relative relevance of radionuclides and pathways for the exposure of members of the public, as a function of age and time after the release. It was also performed an assessment of the effectiveness of protective measures as a function of the moment of their implementation. (author)

  15. Type tests to the automatic system of thermoluminescent dosimetry acquired by the CPHR for personnel dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal

    Molina P, D.; Pernas S, R. [Centro de Proteccion e Higiene de las Radiaciones (CPHR), Calle 20, No. 4113 e/ 41 y 47, Miramar, Ciudad de la Habana (Cuba)]. e-mail: daniel@cphr.edu.cu

    2005-07-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF: Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  16. Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal

    Molina P, D.; Pernas S, R.; Martinez G, A. [Centro de Proteccion e Higiene de las Radiaciones (CPHR), Calle 20 No. 4113 e/41 y 47. Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba)

    2006-07-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  17. Use of radiological evaluation system from the Instituto de Radioprotecao e Dosimetria in the analysis of recent radiation accidents; Utilizacao do sistema de avaliacao radiologica do Instituto de Radioprotecao e Dosimetria na analise de acidentes radiologicos recentes

    Silva, Rodolfo Julio da

    2013-07-01

    The response to an emergency situation involving ionizing radiation requires the joint participation of professionals from various kind of knowledge, belonging to public and private organizations (in the local, state and federal levels). The theme radiation tends to be an additional challenging factor - considering that it's, usually, remembered for its macabre and ominous aspect, in spite of the benefits provided by it - which makes the implementation of actions to protect the public, emergency professionals, the environment and property, very difficult. To this, we can add the complicating factor that, in most cases, the technician (holder of basic or advanced on the subject) is far !Tom the place where this action unfolds. The accident/incident takes the form of a radioactive source (sometimes orphaned, one that gone astray or even stolen) that is found by a person unaware of the risks to which they are being exposed or, let not forget about it, the non-observance of safety standards in industries and workplaces, by their own operators. Thus, before integrating emergency response plans with conventional plans specific to the prompt response to radiological emergencies, it is necessary that some measures had been anticipated and that some actions had, already, been planned - with the intention of mitigate health, psychological and economical damage, in ali of kind. To do this, since in the course of the second decade of the second millennium, and since you own a portable personal computer (Note or Netbook), or even with a mobile device (cellular) with a bit more resources, both of them previously updated, a responder (or even a qualified technician that is next to that fact) may already guide, at least, about a safety distances !Tom the source. Since he had knowledge about some characteristics of the source (its individual data), he can plan ahead about the possible serious situation that unfolds itself and emergency responders will find, when it get to the site. With the situation assessments done, the formal emergency team triggered will can prepare itself (with personnel and technical-materials facilities) to resolve the incident in the shortest time and with the least possible risks. (author)

  18. Computerized dosimetry of I-125 sources model 6711; Dosimetria computarizada de las fuentes de I-125 modelo 6711

    Isturiz, J [Centre de Radiotherapie du Parc, Dijon (France)

    2001-07-01

    It tries on: physical presentation of the sources; radiation protection; mathematical model of I-125 source model 6711; data considered for the calculation program; experimental com probation of the dose distribution; exposure rate and apparent activity; techniques of the use given to the sources I-125; and the calculation planning systems. [Spanish] Trata sobre presentacion fisica de las fuentes, radioproteccion, modelo matematico de las fuentes I-125 modelo 6711, datos considerados en el programa de calculo, comprobacion experimental de la distribucion de dosis, tasa de exposicion y actividad aparente, tecnicas de utilizacion de las fuentes I-125; y los sistemas de planificacion del calculo de las dosis.

  19. Dosimetry of wires and single ribbons of Iridium 192; Dosimetria de alambres y ribbons individuales de Iridio-192

    Mazzucco, L.D. [Centro Medico Nuclear S.R.L. San Juan (Argentina)

    1998-12-31

    The objective of this work is in order to present in table formats the dosimetry of wires and single ribbons of Iridium with lengths 1-12 cm for each one linear source along the bisector which is perpendicular at tissue sources (water) computed for linear activity 1 mCi/cm in the case of wires, and 1 mCi/seed for ribbons. The above tables are of direct use, adaptable at particular cases so they facilitate logarithmic graphics of doses in function of the distance for interpolation and use in the treatments planning. It was shown that for two sources with identical linear activity and total length, one of the equidistant seeds at 1 cm (ribbon) and one wire on the other hand, the differences in dose rates in near positions can be about the 15% so corroborating that it is not possible to use wire tables for seeds neither vice versa. Moreover it was elaborated tables of practical direct use for dose rate in water at c Gy/hr for wires and Ribbons 1-12 cm length and from 0.5-10 cm of distance in the perpendicular bisector at the Iridium implant. (Author)

  20. Development of a guidance guide for dosimetry in computed tomography; Desenvolvimento de um guia orientativo para dosimetria em tomografia computadorizada

    Fontes, Ladyjane Pereira

    2016-07-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  1. Calculation of absorbed dose in water by chemical Fricke dosimetry; Calculo de dose absorvida na agua por dosimetria quimica Fricke

    Rodrigues, Adenilson Paiva, E-mail: adenilson-fisica@hotmail.com.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil); Meireles, Ramiro Conceicao [Fundacao do Cancer, Rio de Janeiro, RJ (Brazil)

    2016-07-01

    This work is the result of a laboratory activity performed in Radiological Sciences Laboratory (CRL), linked to the State University of Rio de Janeiro (UERJ). This practice aimed to determine the absorbed dose to water, through the primary calibration method called dosimetry Fricke, which consists of ferrous ions (Fe + 2) to ferric (Fe + 3), generated by water radiolysis products which is the structural change of water molecule caused by ionizing radiation. A spectrophotometer was used to extract data for analysis at a wavelength (λ) 304 and 224 nm with function of measuring the absorbance using bottles with irradiated and nonirradiated Fricke solution. (author)

  2. Thermoluminescent dosimetry in dentistry students in radiological training; Dosimetria termo-luminiscente en estudiantes de odontologia en entrenamiento radiologico

    Loya, M.; Duarte, R. [Escuela de Odontologia, Universidad Autonoma de Chihuahua (Mexico); Montero, M.E. [CIMAV, Chihuahua (Mexico); Gonzalez, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Ojeda, S.L.; Sanin, L.H. [Facultad de Enfermeria y Nutriologia, Chihuahua (Mexico)

    2007-07-01

    Full text: In this work, the obtained results of the mensuration of the equivalent one are presented of dose (E), in students of the career of Dentistry who during their training in radiology complete the three lists of patient, odontologist and observer. The study one carries out with 35 students (Odontologists), 7 men and 28 women, with ages between 20 and 24 years. A characterization of risk was made following the methodology of the Agency for the environmental control of United States (EPA), counting the number of shots in each list, during the time of training. The effective energy of the X rays used was of 24 KeV. The irradiation technique understood two modalities; the first one with 3 shots of 1.25 seconds and the second with 5 shots of 0.6 seconds. The measurement of E, was carried out with thermoluminescent dosemeters (TL) of LiF:Mg,Cu,P+PTFE, developed in the National Institute of Nuclear Research (ININ). The homogenization of the dosemeters showed a variation in its response to the radiation of 1.85%DS. For the odontologist position, the dosemeters was placed to the height of the chest and the measurement was multiplied by the number of shots that it was 304. The E value was of 3.62 mSv/four-month (11 mSv/year), without any safety equipment and of 2.02 mSv/four-month (6.14 mSv/year), when was considered the scenario for this position with use of vest and lead collar, like safety equipment, diminishing E, almost 50%. In the case of the corresponding position to patient, E, it was measured in different organs of interest, the obtained results are compared with the international standards. Recommendations are given for similar cases. (Author)

  3. Dose measurements in dental radiology using thermoluminescent dosimetry;Medicoes de dose em radiodiagnostico odontologico utilizando dosimetria termoluminescente

    Chiara, Ana Claudia M. de; Costa, Alessandro M. [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras; Pardini, Luiz Carlos [Universidade de Sao Paulo (FORP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Odontologia

    2009-07-01

    The aim of this work was the implementation of a code of practice for dosimetry in dental radiology using the technique of thermoluminescent dosimetry. General principles for the use of thermoluminescent dosimeters were followed. The irradiations were performed using ten X-ray equipment for intra-oral radiography and an X-ray equipment for panoramic radiography. The incident air kerma was evaluated for five different exposure times used in clinical practice for intra-oral radiographs. Using a backscatter factor of 1.2, it was observed that approximately 40% of the entrance skin dose values found for intra-oral radiographs are above the diagnostic reference level recommended in national regulation. Different configurations of voltage and current were used representing the exposure as a child, woman and man for panoramic radiographs. The results obtained for the air kerma area product were respectively 53.3 +- 5.2 mGy.cm{sup 2}, 101.5 +- 9.5 mGy.cm{sup 2} and 116.8 +- 10.4 mGy.cm{sup 2}. The use of thermoluminescent dosimetry requires several procedures before a result is recorded. The use of dosimeters with ionization chambers or semiconductors provides a simple and robust method for routine measurements. However, the use of thermoluminescent dosimetry can be of great value to large-scale surveys to establish diagnostic reference levels. (author)

  4. Dosimetry computer module of the gamma irradiator of ININ; Modulo informatico de dosimetria del irradiador gamma del ININ

    Ledezma F, L. E.; Baldomero J, R. [ININ, Gerencia de Sistemas Informaticos, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Agis E, K. A., E-mail: luis.ledezma@inin.gob.mx [Universidad Autonoma del Estado de Mexico, Facultad de Ingenieria, Cerro de Coatepec s/n, Ciudad Universitaria, 50100 Toluca, Estado de Mexico (Mexico)

    2012-10-15

    This work present the technical specifications for the upgrade of the dosimetry module of the computer system of the gamma irradiator of the Instituto Nacional de Investigaciones Nucleares (ININ) whose result allows the integration and consultation of information in industrial dosimetry subject under an outline client-server. (Author)

  5. Biological Dosimetry of X-rays by micronuclei study; Dosimetria Biologica de rayos-X mediante el estudio de micronucleos

    Gomez, E.; Silva, A.; Navlet, J.

    1991-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes citokinetics blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree centigree has been produced. Experimental data is fitted to model Y=C+ {alpha}D+BD''2 where Y is the number of micronuclei per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 24 refs.

  6. Biological Dosimetry of X-rays by micronuclei study; Dosimetria Biologica de rayos-X mediante el estudio de micronucleos

    Gomez, E; Silva, A; Navlet, J

    1991-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical an cytogenetics data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable, in this case, the study of micronuclei in peripheral blood lymphocytes citokinetics blocked can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using micronuclei assay for X-rays at 250 kVp, 43,79 rads/min and temperature 37 degree centigree has been produced. Experimental data is fitted to model Y=C+ {alpha}D+BD''2 where Y is the number of micronuclei per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 24 refs.

  7. Differences between cross-section libraries for neutron dosimetry; Diferencas entre bibliotecas de secoes de choque para dosimetria de neutrons

    Tardelli, T.C.; Stecher, L.C.; Coelho, T.S.; Castro, V.A. De; Cavalieri, T.A.; Menzel, F.; Giarola, R.S.; Domingos, D.B.; Yoriyaz, H., E-mail: tiago.tardelli@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Engenharia Nuclear

    2013-08-15

    Absorbed dose calculations depend on a consistent set of nuclear data used in simulations in computer codes. Nuclear data are stored in libraries, however, the information available about the differences in dose caused by different libraries are rare. The libraries are processed by a computer system to be able to be used by a radiation transport code. One of the systems capable of processing nuclear data is the NJOY system. The objective of this study is to evaluate the nuclear data libraries for neutrons available in the literature, and to quantify the differences in absorbed dose obtained using the libraries JENDL 4.0, JEFF 3.3.1 and ENDF/B.VII. The absorbed dose calculation was performed on a simple geometric model, as spheres, and in anthropomorphic model of the human body based on the ICRP-110 for neutron transport simulation using the MCNP5 code. The results were compared with literature data. The results obtained with cross sections from the libraries JEFF and ENDF/B.VII have shown to be identical in most cases, except for one case where the difference has exceeded 10%. The results obtained with JENDL library has shown to be considerably different in most cases comparing to other two libraries. Some differences were over 200%. The dose calculations showed differences between the libraries, which is justified by differences in the cross sections. It has been observed that the cross sections values of certain nuclides assume quite different values in different libraries. These differences in turn cause considerable differences in dose calculations. (author)

  8. Application of numerical analysis methods to thermoluminescence dosimetry; Aplicacion de metodos de analisis numerico a la dosimetria por termoluminiscencia

    Gomez Ros, J M; Delgado, A

    1989-07-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs.

  9. Thermoluminescent dosimetry in the radiodiagnostic area of the INNSZ; Dosimetria termoluminiscente en el area de radiodiagnostico del INNSZ

    Azorin V, J.C.; Azorin N, J.; Rivera M, T. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    1998-12-31

    During the year 1997 the Secretaria de Salud through the Direccion de Riesgos Radiologicos published the Mexican Official Standard about the medical diagnostic using X-rays in the Diario Oficial de la Federacion. They are of obligatory observance for all hospitals and radiological rooms which have medical diagnostic with X-ray equipment in the country. These standards were emitted with the purpose improve the conditions as for safety and radiological protection it is referred employing this type of ionizing radiation emitter equipment. Also it is presented the evaluation results about conditions existing about in thirteen X-ray medical diagnostic rooms in the Instituto Nacional de la Nutricion with the purpose of providing the radiological protection means toward the occupationally exposure personnel. It was realized measurements of each one of the blinding barriers for the X-ray equipment and it was suggested the appointments arrangement. (Author)

  10. Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones

    Chavez B, A

    1991-02-15

    The measure of different radiation types, with specific dosemeters, requires that the absorbed dose should be measured with accuracy by some common standard. The existent problem around the dosimetry of accelerated electrons has forced to the development of diverse detector types that after having analyzed the characteristics; dependability and reproducibility are used as dosemeters. Recently the calorimeters have been developed, with the purpose of carrying out dosimetry for electron accelerators. The RISO laboratory in Denmark, in it 10 MeV accelerator had been used for the dosimetry those water calorimeters, later on, using the principle of the water calorimeter, it was designing one similar, for the accelerator of 400 keV. Recently manufactured simple calorimeters of graphite have been used, which can be used in both accelerators of 10 MeV and 400 keV. (Author)

  11. Accreditation ISO/IEC 1705 in dosimetry: Experience and results; Acreditacion ISO/IEC 17025 en dosimetria: Experiencia y resultados

    Martin Garcia, R.; Navarro Bravo, T.

    2013-07-01

    The objective of this work is to present the experience in the process of accreditation of the radiation dosimetry service in which there are trials for the determination of radiation doses due to internal and external exhibitions. Is They describe the aspects that were considered for the design and development of a system of quality and results after its implementation. A review of the benefits accreditation has been reported to the organization is finally made. (Author)

  12. Dosimetry of professionals involved in radio guided surgery; Dosimetria de los profesionales involucrados en la cirugia radioguiada

    Barreto, A. C.; Cardoso, G.; Ferreira, L. S.; Santos, A. I.

    2013-07-01

    The procedure of sentinel node localization is important because it allows less invasive staging of breast cancer. With the capture probe after intradermal injection of the radiopharmaceutical, the surgeon can identify the location of the sentinel node. The use of radioactive materials, generated considerable concern in terms of radiation exposure. The main objective is to evaluate the possible individual dose of each professional involved in the process of radio-location. (Author)

  13. Dosimetry of the patient and occupational in interventional procedures; Dosimetria del paciente y ocupacional en procedimientos intervencionistas

    Andisco, D. [Universidad de Buenos Aires, Facultad de Medicina, Paraguay 2155, C1121AAA Buenos Aires (Argentina); Bourel, V.; Schmidt, L.; Fernandez, N., E-mail: dandisco@fmed.uba.ar [Universidad Favaloro, Facultad de Ciencias e Ingenieria, Solis 453, C1078AAI, Buenos Aires (Argentina)

    2014-08-15

    The big necessity to estimate the entrance doses in skin that the patients receive when are exposed to interventional procedures and the personal dosimetry of the professionals that work in these procedures in operating room, has taken to the analysis of different possibilities that allow to carry out these estimates. The objective of this work was to analyze the possibility of using Optically Stimulated Luminescence dosimeters; comparing the results with ionizing cameras and electronic personal dosimeters. To carry out these estimates, we work with a X-ray equipment Phillips Allure, acrylic phantoms, a dosimetry system formed by ionization camera and dosimeter UNIDOS E, OSL (Nano dots) dosimeters and electronic lavalieres Aloka brand, PDM 117 models. To estimate the doses that the patients receive, entrance dose was measured in skin and in personal dosimetry inside places where the medical professionals are habitually located in different situations among 5 and 60 irradiation min. In the case of direct radiation, the OSL (Nano dots) present reliable readings and only were dispersed values for the measurements of secondary radiation. The measured values and the linking among them were also analyzed. The OSL (Nano dot) dosimetry behaves reliable way when is located in the ranges of more dose to 0,1 mGy, according to the maker indications and fundamentally for direct beams of the hemodynamics equipment being ideal for the measurement of entrance dose in skin. For the Nano dots use in personal dosimetry the results should be read carefully for values major to 0,1 mGy and being completely inappropriate for minor values. (Author)

  14. A new implementation of multichannel radiochromic film dosimetry; Una nueva implementacion del analisis multicanal para la dosimetria mediante peliculas radiocromicas

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Tores Olombrada, M. V. de

    2014-07-01

    The aims of this paper are to carry out a new implementation of the multichannel radiochromic film dosimetry (Micke A, Lewis D, Yu X. Multichannel film dosimetry with nonuniformity correction. Med Phys 2011;38:2523-34), to quantify the variation in gamma index as compared to the single channel film dosimetry, and to determine if the procedure achieves similar results by means of a different scanner that the one used by Micke et al. Radiochromic EBT2 films and a Microtek 9000 XL scanner were used. Our procedure simplifies the system calibration splitting it into two factors, manufactured batch and digitalization specific. Absorbed dose spatial distributions from an open radiotherapy beam without any modulation and 20 IMRT treatments were determined. Their gamma index maps were calculated and a comparison of the results from single channel and multichannel dosimetry was performed. A 5% mean increase in concordance was obtained by using the multichannel film dosimetry. Our results are similar to those reported by Micke et al. even though we are using a different scanner. (Author)

  15. Radiation chemical dosimetry by means of nitrate-nitrite; Dosimetria quimica de la radiacion aplicacion del sistema nitrato-nitrito

    Tormo Ferrero, M J

    1977-07-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolysis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (Author) 22 refs.

  16. A definitive method for dosimetry with radiochromic movie; Un metodo definitivo para la dosimetria con pelicula radiocromica

    Miras del Rio, H.; Arrans Lara, R.

    2013-07-01

    Despite the undoubted benefits of radiochromic film as a two-dimensional radiation detector, the manufacturing process and characteristics of scanners make to present some inherent difficulties that result that its use is complex, tedious, and if not performed so appropriate, imprecise. A protocol that simplifies the calibration process while reducing the number of films used for this purpose is proposed systematically corrects several difficulties, both inherent in the manufacture of the film as the reader and, what is more important achieves levels comparable to those of other more widespread use detectors accuracy. (Author)

  17. Study of dosimetry CT in Skull for pediatric patients; Estudio de dosimetria TC en craneo para pacientes pediatricos

    Ramos Amores, D.; Serna Berna, A.; Mata Colodro, F.; Puchades Puchades, V.

    2013-07-01

    The dose that receiving the patients in CT studies is the highest that can be received in a study of Radiology. If patients are children and we do studies with the same parameters as adults, they will receive a higher dose of radiation. This work seeks to expose the result of a dosimetric study on CT for children aged 0-15, carried out at the Hospital General Universitario de Santa Lucia in Cartagena during the year 2012. (Author)

  18. EPR dosimetry in tooth enamel by x radiation; Dosimetria EPR en esmalte dental irradiado con rayos X

    Dubner, Diana; Perez, Maria del Rosario; Gisone, P. [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)] E-mail: ddubner@cae.arn.gov.ar; Fainstein, C.; Winkler, E. [Comision Nacional de Energia Atomica (CNEA), San Carlos de Bariloche (Argentina). Centro Atomico Bariloche]|[Universidad Nacional de Cuyo, Mendoza (Argentina). Inst. Balseiro; Saravi, Margarita [Comision Nacional de Energia Atomica (CNEA) (Argentina). Centro Atomico Ezeiza; Davila, Francisco [Ateneo Argentino de Odontologia, Buenos Aires (Argentina)

    2001-07-01

    Tooth enamel, extracted from molars, was irradiated with 66 keV X-rays, with doses up to 1 Gy. The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra. The radiation induced paramagnetism is measured, at room temperature, by ESR spectroscopy. The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magnetrons) g=2,0041, and g1=2,0018, g2=1,9972. The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0 Gy

  19. Dosimetria “in vivo” para implantes ginecologicos de cancer de cervix, con braquiterapia de alta tasa de dosis (hdrb

    Guillen G., Oscar O.; Duran S., Rosalia

    2009-01-01

    SOLCA Guayaquil en el Servicio de Braquiterapia dispone de un equipo de carga diferida de alta tasa de dosis, Microselectron HDR de la Empresa Nucletron, equipado con una fuente de Ir192, para la realización de tratamiento a pacientes portadores de cáncer en diferentes localizaciones. Se usa un maniquí de sólido de PMMA tipo 9193, de la PTW con el objetivo de determinar la tasa de kerma en aire de la fuente de Ir192, cuyo error no supera el 0.5%. Adicionalmente, se establece un mecanismo ...

  20. Use of radiological evaluation system from the Instituto de Radioprotecao e Dosimetria in the analysis of recent radiation accidents

    Silva, Rodolfo Julio da

    2013-01-01

    The response to an emergency situation involving ionizing radiation requires the joint participation of professionals from various kind of knowledge, belonging to public and private organizations (in the local, state and federal levels). The theme radiation tends to be an additional challenging factor - considering that it's, usually, remembered for its macabre and ominous aspect, in spite of the benefits provided by it - which makes the implementation of actions to protect the public, emergency professionals, the environment and property, very difficult. To this, we can add the complicating factor that, in most cases, the technician (holder of basic or advanced on the subject) is far !Tom the place where this action unfolds. The accident/incident takes the form of a radioactive source (sometimes orphaned, one that gone astray or even stolen) that is found by a person unaware of the risks to which they are being exposed or, let not forget about it, the non-observance of safety standards in industries and workplaces, by their own operators. Thus, before integrating emergency response plans with conventional plans specific to the prompt response to radiological emergencies, it is necessary that some measures had been anticipated and that some actions had, already, been planned - with the intention of mitigate health, psychological and economical damage, in ali of kind. To do this, since in the course of the second decade of the second millennium, and since you own a portable personal computer (Note or Netbook), or even with a mobile device (cellular) with a bit more resources, both of them previously updated, a responder (or even a qualified technician that is next to that fact) may already guide, at least, about a safety distances !Tom the source. Since he had knowledge about some characteristics of the source (its individual data), he can plan ahead about the possible serious situation that unfolds itself and emergency responders will find, when it get to the site. With the situation assessments done, the formal emergency team triggered will can prepare itself (with personnel and technical-materials facilities) to resolve the incident in the shortest time and with the least possible risks. (author)

  1. Dosimetry in medical specialist in procedures of interventionist radiology; Dosimetria en medico especialista en procedimientos de radiologia intervencionista

    Gaona, E. [Universidad Autonoma Metropolitana, Unidad Xochimilco, Calz. del Hueso 1100, Col. Villa Quietud, 04960 Mexico D. F. (Mexico); Vazquez V, J. A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico); Izeta G, A. C. [Hospital Central Militar, Periferico y Av. Ejercito Nacional s/n, 11200 Mexico D. F. (Mexico); Azorin V, J. C. [Universidad de Guanajuato, Instituto de Fisica, Loma del Bosque 103, 37150 Leon, Guanajuato (Mexico); Arreola, M., E-mail: gaen1310@correo.xoc.uam.mx [Shands Hospital at University of Florida, Department of Radiology, PO Box 100374, Gainesville, FL 32610-0374 (United States)

    2014-08-15

    In this work are presented the experimental results of determining the dose in different body parts, measured by thermoluminescent dosimeters, to medical specialists of implantation procedures of definitive cardiac pacemaker. The medical personnel in ten intervention procedures were controlled according to the procedure type, pathological indication, fluoroscopy time and machine generating estimates of the patient doses. The doses to the extremities of the cardiologist were measured by means of thermoluminescent dosimeters (TLD). The domains of first level in the hand are in the index finger of the left and the right hand. The medium doses of the skin in the eyes, a report of the dose received during each type of intervention procedure in the glandular thyroid and fingers of the cardiologists is made. The results represent the integrated dose to the cardiologist, received during the implantation procedures of definitive cardiac pacemaker in the same patient. By a half time of detection of 70 minutes for patient, the half dose of the skin, received for the right and left hand, ascended to 1,4 mSv, under the glove. In conclusion, the dose average for the dosimeters of the thyroid gland and forehead was varied from 0,41 up to 1,14 mSv for study. The exposure to the X-rays is a topic to consider, more important every time on the development of systematic procedures little invasive, including the angiography, catheter, worker and patient. (Author)

  2. Tl dosimetry around equipment s for dental radiography; Dosimetria TLD en torno a equipos para radiografia dental

    Medrano, E.; Robles G, M. A. [Universidad Autonoma de Zacatecas, Unidad Academica de Odontologia, Apdo. Postal 336, 98000 Zacatecas (Mexico); Vega C, H. R.; Letechipia de L, C.; Hernandez D, V. M., E-mail: edumeco@yahoo.com.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-08-15

    The ambient dose equivalent around X-rays units used in dentistry has been measured. The radiation that escapes of the tail stock of the X-rays equipment was also measured, and the dose in the surfaces of a polyethylene spherical mannequin and other of water, used to represent the patient and the operator, respectively. The study was realized with thermoluminescent dosimeters of the type 100. The operation conditions of the X-rays units were varied when the ambient dose equivalent was measured. In the other measurements the equipment s were operated to 70 k Vp and 8 m A. In the ambient dose equivalent was found asymmetry, likewise the due dose to the radiation that escapes of one of tail stocks was also asymmetric. The dose values in the mannequins went minors to the recommended reference values. (Author)

  3. Estimations of internal dosimetry: practical calculations of incorporated activity; Estimaciones de dosimetria interna: calculos practicos de actividad incorporada

    Cortes C, A. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)

    2003-07-01

    The National Commission of Nuclear Security and Safeguards (CNSNS) carries out periodically measurements of corporal activity to Occupationally Exposed Personnel (POE) to determine that the received doses are in according to that settled down in the General Regulation of Radiological Security. In this work the results of the incorporated activity estimates starting from the results of the measurements that were carried out in the one CNSNS laboratory are presented, with which it should be determine lastly the internal dose. Its were used different methodologies to estimate the incorporated activity: estimate with isolated data, estimate with global data and method of the best estimate, demonstrating this last to be the more appropriate to determine the internal dose. (Author)

  4. A new method for dosimetry with films radiochromic; Un nuevo metodo para la dosimetria con peliculas radiocromica

    Mendez Carot, I.

    2013-07-01

    in this paper a new method is presented and the results of the comparison between the calibration is summarized based on a planning reference and calibration obtained from the irradiated fragments measure different dose levels multichannel compare dosimetry based on the weighted average dosimetry described by Micke et al.(present in the FilmQAPro software) and, finally, show different results obtained with the method proposed in several applications clinics. (Author)

  5. Neutron dosimetry. Environmental monitoring in a BWR type reactor; Dosimetria de neutrones. Monitoreo ambiental en un reactor del tipo BWR

    Tavera D, L; Camacho L, M E

    1991-01-15

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  6. Dosimetry on the radiological risks prevention in radiotherapy; La dosimetria en la prevencion de riesgos radiologicos en radioterapia

    Fornet R, O. M.; Perez G, F., E-mail: nuclear2@citmahlg.holguin.inf.cu [Delegacion Territorial del CITMA, Peralta 16 esq. P. Feria, Rpto. Peralta, 80400 Holguin (Cuba)

    2014-08-15

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  7. Statistical analysis of personal dosimetry of exposed workers; Analisis estadistico de la dosimetria personal de trabajadores expuestos

    Sanchez Munoz, F. J.; Alejo Luque, L.; Mas Munoz, I.; Serrada Hierro, A.

    2013-07-01

    The dosimetry centers accredited by the Nuclear Safety Council (CSN) normally report overcoming legal limits, or some fraction thereof, but do not provide comparative dosimetric criteria indicating if assigned to a given dose is large TPE or small relative to that of their peers. In order to help to resolve the difficulties mentioned ds, it has developed an application that statistically processes the dosimetric data provided by the National Dosimetry Center. (Author)

  8. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  9. Thermoluminescent dosimetry in the radiodiagnostic area of the INNSZ; Dosimetria termoluminiscente en el area de radiodiagnostico del INNSZ

    Azorin V, J C; Azorin N, J; Rivera M, T [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    1999-12-31

    During the year 1997 the Secretaria de Salud through the Direccion de Riesgos Radiologicos published the Mexican Official Standard about the medical diagnostic using X-rays in the Diario Oficial de la Federacion. They are of obligatory observance for all hospitals and radiological rooms which have medical diagnostic with X-ray equipment in the country. These standards were emitted with the purpose improve the conditions as for safety and radiological protection it is referred employing this type of ionizing radiation emitter equipment. Also it is presented the evaluation results about conditions existing about in thirteen X-ray medical diagnostic rooms in the Instituto Nacional de la Nutricion with the purpose of providing the radiological protection means toward the occupationally exposure personnel. It was realized measurements of each one of the blinding barriers for the X-ray equipment and it was suggested the appointments arrangement. (Author)

  10. Proposal of specific policies for wind energy in Brazil, after the first phase of the PROINFA Programme; Propostas de politicas especificas para energia eolica no Brasil apos a primeira fase do PROINFA

    Dutra, Ricardo Marques

    2007-04-15

    This work aims to propose viable strategies, using several criteria, for the development of Wind Energy in Brazil, to be implemented from the second phase of the PROINFA (Programa de Incentivo a Fontes Alternativas de Energia/Incentive Program to Alternative Energy Sources) onwards. It describes the main incentives for fostering renewable energy sources for electricity generation both under a theoretical point of view and through an analysis of the international experience in this field. It also present an analysis of the new Brazilian electric power sector, specially of the evolution of the politics for renewable power sources. Given the international experience and the current state of the Brazilian Utilities, this work proposes and evaluates quantitative and qualitatively strategies for the application of incentives to Wind Energy, beyond those already applied in PROINFA. The criteria for these strategies are: (1) reduction of greenhouse emissions by utilities; (2) optimization of the hydroelectric system; (3) industrial and regional development and (4) an increase of the participation of alternative renewable sources in the power matrix. The results obtained in this work show clearly the viability of several strategies for Wind Energy development in Brazil: for strategy (1), it was identified that Quota/Green Certificate is more adequate for the Brazilian case; for both strategies (2) and (3) it was identified that the Feed-In system is the most adequate one. Finally, for the strategy (4) the Feed-In system is more adequate for a short-term strategy, while, for the long-term, the harmonization of the Feed-In system and Quota/Green Certificate is more appropriate for wind energy development in Brazil. (author)

  11. Evaluación de la respuesta de isotipos de inmunoglobulina especifica a Leishmania en leishmaniasis tegumentaria Americana Evaluation of specific immunoglobin isotype response to Leishmania in American tegumentary leishmaniasis

    Maricel Labrada

    1989-09-01

    Full Text Available Con el fin de determinar las clases de anticuerpo producido contra el parásito y la cinética de los mismos en relación a la evolución de la infección, se estudiaron los sueros de 133 pacientes infectados con Leishmania del complejo braziliensis. Se utilizó la prueba de inmunofluorescencia indirecta y amastigotas de L. mexicana amazonensis como antígeno. En los sueros obtenidos al momento de consultar para el diagnóstico se encontró IgM en 54 de los sueros absorbidos con Straphylococcus aureus Cowan I y en 5 de los no absorbidos. La IgM sólo se encontro en los sueros de pacientes con tiempo devolución de las lesiones Leishmania-specific immunoglobulin subclass response was evaluated in 133 patients infected with Leishmania braziliensis. The indirect immunofluorescent antibody test (IFAT was employed with amastigotes of L. mexicana amazonensis as antigen. Among the 133 sera obtained at consultation fo rdiagnosis of active lesions, IgM was detected in 54 following absorption with Staphylococcus aureus Cowan strain I, and in 5 sera prior to absorption. IgM reactive with Leishmania antigen was only found in sera from patients whose lesions had envolved over past two months or less. Leishmania-specific IgG was detected in all sera prior to absorption. Sera obtained at the time of recurrence of after complete healing of lesions presented only specific IgC. The combined use of the Montenegro skin test and specific IgM increased the sensitivity of immunodiagnostic methods in patients with lesions of less than 2 months duration. Normal control volunteers were negative for specific IgM and unreactive to Montenegro skin testin. Among 16 patients with non-leishmanial lesion, 3 with sporotrichosis showed IgG reactive with Leishmania; none, including 4 with lesions of less than two months duration, showed specific IgM. We conclude that in patients infected with L. brasiliensis the presence of specific IgG and IgM is associated with the time of lesion evolution and the primary or recurrent nature of the lesions. In addition, the combined use of IgM titer and Montenegro reactivity is of potential utility in the diagnosis of early lesions.

  12. Specific absorption in vivo of the [{sup 125} I] insulin by the Chrysemys dorbigni turtle thyroid; Captacao especifica in vivo da [{sup 125} I] insulina pela tireoide de tartarugas Chrysemys dorbigni

    Coutinho, Ligia Maria Barbosa

    1982-12-31

    Based on researches that demonstrate the presence of insulin receptor sites in hypophysis and supra renal, we investigate this hormone specific absorption by the thyroid gland. We used adult males and females Chrysemys dorbigni turtles. It was used a in vivo method consisting of [{sup 125} I] (2 x 10{sup 6} cpm/Kg) insulin intra-aorta administration, and counting of the radioactivity in the gland and blood. 101 refs., 10 figs., 2 tabs.

  13. Optimization of the synthesis of a high specific activity 125{sup I}-labelled hapten for radioimmunoassays; Optimizacion de un metodo de preparacion de un radiohapteno-125''I para ria de alta actividad especifica

    Suraez, C.; Paz, D.; Simon, M. A.; Romero del Hombrebueno, B.

    1994-07-01

    In this first report it is described the synthesis, separation and purification of the 2-radioiodinated histamine- I-labelled histamine by a mixed anhydride reaction. About 75% incorporation of I{sup -}125, from Na{sup 1}25I, was achieved with a molecular ratio of 1:1 mixed anhydride:histamine. The radiochemical purity of the conjugate by TLC was > 99% and its theoretical specific activity, 3850 {mu}Ci/{mu}g. Dissolved in ethanol and held at -20 degree centigree under darkness decomposition on storage didn't exceed 1% per month. (Author) 13 refs.

  14. Optimization of the synthesis of a high specific activity 125{sup I}-labelled hapten for radioimmunoassays; Optimizacion de un metodo de preparacion de un radiohapteno-125''I para ria de alta actividad especifica

    Suraez, C; Paz, D; Simon, M A; Romero del Hombrebueno, B

    1994-07-01

    In this first report it is described the synthesis, separation and purification of the 2-radioiodinated histamine- I-labelled histamine by a mixed anhydride reaction. About 75% incorporation of I{sup -}125, from Na{sup 1}25I, was achieved with a molecular ratio of 1:1 mixed anhydride:histamine. The radiochemical purity of the conjugate by TLC was > 99% and its theoretical specific activity, 3850 {mu}Ci/{mu}g. Dissolved in ethanol and held at -20 degree centigree under darkness decomposition on storage didn't exceed 1% per month. (Author) 13 refs.

  15. Process of nourishment staggered for elimination of nitrogen. Specific characteristics of the process. Strategies of control; Proceso de alimentacion escalonada para eliminacion de nitrogeno. Caracteristicas especificas del proceso. Estrategias de control

    Rodrigo, J. C.; Cortacans, J. A. [Infilco Espanola, s.a (Spain)

    2002-07-01

    This article illustrates the step fed activated sludge process advantages for biological nitrogen removal. This configuration, also known as ALP-HA (alternative phase step feed) process, reduces biological reactor volume, avoids internal sludge recycling and optimizes organic matter consumption for denitrification. Besides, it is offered the possibility to work with a calibrated specific model as a tool for the evaluation, design and operation of the process. To end up, some efficient operation strategies for the three-step ALPHA process in denitrification-nitrification reactors are proposed. (Author) 13 refs.

  16. Conversion factors in patient activity external rate Hp (10) in the patient environment in metabolic therapy with 1-131; Coeficientes de conversion actividad en pacientes a tasa externa Hp(10) en el entorno del paciente en terapia metabolica con I-131

    Barquero Sanz, R.; Chambung, K.; Jaesseong, L.; Castillo Belmonte, A. del; Alonso Hernandez, D.; Andres Rodriguez, C.; Tortosa Oliver, R.; Mari Palacios, A.

    2011-07-01

    The purpose of this study is to determine the conversion factors (h) of R-131 to H measured in the patients environment, as the provision of activity in the same body or tumor, and analyzing the magnitude of the variables most significant influence on the measure of H. Applying the same procedure developed by the working group SEFM based on external exposure measurements made CHin taking the patient during their hospital stay, will optimize the procedure.

  17. Need to monitoring the particulate components and gaseous components of the I-131 in air, on Radiological monitoring networks. impact of the accident of Fukushima Dai-chi in Spain; Necesidad de monitorizar las componentes particulada y gaseosa del {sup 1}31I en aire, en redes de vigilancia radiologica. Impacto en Espana del accidente de Fukushima DAI-ICHI

    Baeza Espasa, A.; Caballero Andrada, M.; Corbacho Merino, J. A.; Ontalba Salamanca, M. A.; Rodriguez Perulero, A.; Valencia Corrales, D.; Vasco Vargas, J.

    2013-07-01

    Following a nuclear accident with significant overseas evacuations, it should be accurately determined concentration radio iodines into the atmosphere, given its important contribution to the radiological impact produced. Automatic networks radiation monitoring aim to provide as quickly as possible, reliable information on these radiological changes, to take necessary countermeasures. (Author)

  18. Formulation, radiopharmaceutical kinetics and dosimetry of the {sup 188}Re(V)-DMSA complex; Formulacion, radiofarmacocinetica y dosimetria del complejo {sup 188}Re(V)-DMSA

    Garcia S, L; Ferro F, G [Departamento de Materiales Radiactivos. Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Salazar, Estado de Mexico (Mexico); Murphy, C.A. de; Pedraza L, M [Departamento de Medicina Nuclear, Instituto Nacional de la Nutricion, Salvador Zubiran, Mexico D.F. (Mexico); Azorin N, J [Departamento de Fisica, Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico)

    1999-07-01

    It was developed through experimental design (ANOVA), a formulation to prepare the {sup 188} Re(V)-Dmsa complex. Likewise, there were realized studies of radiopharmaceutical kinetics and internal dosimetry in animals, its normal and with induced tumors, considering an open bi compartmental model using the MIRD methodology. The {sup 188} Re(V)-Dmsa complex was obtained with a radiochemical purity greater than 95% incubating 30 min at 90 Centigrade under the following formulation: [SnCl{sub 2}] = 1.4 mg/ml, [ascorbic acid] = 0.5 mg/ml, p H = 2.0 - 3.0. The stability test of the formulation, shows that after 48 h of its preparation, does not produce radiolytic degradation neither chemical decomposition. The radiopharmaceutical kinetics data show an average residence time 7.2h, velocity constant {alpha} = 0.6508h{sup -1} and {beta} = 0.1046 h{sup -1} with an apparent distribution volume 6.9 l. The main elimination via was renal and it was observed osseous caption with an accumulated activity 522.049 {+-} 62 MBq h (residence time 14.1094 {+-} 1.69h). In according with the dosimetric calculations, by each 37 MBq injected, the equivalent dose at the tumor was 9.67{+-} 0.33 Sv/g, for an effective dose 0.292 {+-} 0.0017 mSv/MBq. The images obtained in the gamma camera of the mice with induced tumors, show that do not have significant accumulation in the metabolic organs. The caption in bone and in tumors induced of the {sup 188} Re(V)-Dmsa complex, show its potential for be used as a palliative agent for pain in patients with osseous metastasis and in the treatment of tumors of soft tissue. (Author)

  19. Personal dosimetry calculations by means of radio pharmacokinetic and gamma graphic studies; Calculos de dosimetria personalizada por medio de estudios radiofarmacocineticos y gammagraficos

    Arteaga de Murphy, C; Ferro F, G; Pedraza L, M; Montoya M, C E [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Vasco de Quiroga 15, 14000 Mexico D.F. (Mexico)

    2000-07-01

    The determination of the absorbed radiation dose is an essential factor to assess the risk to patient with a diagnostic study of nuclear medicine but over all it is indispensable for predicting the efficiency of individualized radio pharmacotherapy and weighting up the risk/benefit of the treatment. In studies for diagnostic or/and treatment of nuclear medicine generally the absorbed radiation dose is not determined for each patient since the methods for estimating it are laborious and include complex models such biological as mathematical, therefore is very important to have a relatively easy method. The obtained data with {sup 99m} Tc-Abp., a new radiopharmaceutical for osseous gammagraphy, were used with the purpose of exemplifying a practical method. The radio pharmacokinetic parameters were determined during 24 hours in 10 health voluntaries and serial gamma grams were taken during two hours to another voluntaries. The obtained data were used to estimate, with the MIRDOSE3 computer program, the absorbed radiation dose in an osseous dragging with {sup 99m} Tc-Abp. is low: 0.00472 m Gy/MBq to osseous marrow, mainly to the vertebral column and femur, and 0.00169 m Gy/ MBq to whole body. These data are lower than those informed in the medical literature for other bis phosphonates. (Author)

  20. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results;Caracterizacao de dosimetros termoluminescentes para dosimetria de pacientes em radiodiagnostico - resultados iniciais

    Castro, William J.; Squair, Peterson L. [Faculdade Novo Rumo, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gonzaga, Natalia B. [Universidade Unincor, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria S.; Silva, Teogenes A. da [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  1. Progetto EURAMET: HLT03 DUTy - Dosimetria per terapie ultrasonore. Confronto tra metodi di misura - EURAMET: HLT03 DUTy - Dosimetry for ultrasound therapy. Intercomparison of methods

    Giovanni Durando

    2016-03-01

    Full Text Available La mancanza di una definizione della dose ultrasonora rende di fatto impossibile la valutazione della più appropriata “quantità” energia ceduta ai tessuti dal fascio ultrasonoro emesso da un trasduttore durante una terapia. Il progetto di ricerca “Dosimetry for Ultrasound Therapy - DUTy”, finanziato dal programma di ricerca EURAMET EMRP, aveva tra i suoi principali obiettivi, oltre al confronto interlaboratorio che validasse le capacità metrologiche dei laboratori partecipanti, la ricerca della definizione di dose ultrasonora che consentisse la definizione di un piano terapeutico specifico per ogni paziente. ------ Standardized and traceable dose has not yet been developed for medical ultrasound applications. This means that the ‘amount’ of ultrasound required for a particular therapy cannot be calculated and that the ‘amount’ actually delivered quantified. The aim of EURAMET EMRP project “Dosimetry for Ultrasound Therapy - DUTy” project was developing the metrological infrastructure (definitions, validated measurement and modelling methods which underpins the specification of dose for therapeutic ultrasound applications allowing appropriate treatment planning and risk assessment.

  2. Development and application of a pediatric head phantom for dosimetry in computed tomography; Desenvolvimento e aplicacao de um simulador pediatrico craniano para dosimetria em tomografia computadorizada

    Martins, Elaine Wirney

    2016-11-01

    To determine the exposure levels and the absorbed dose in patients undergoing CT scans, is necessary to calculate the CT dose index in measurements with a PMMA or water phantom. The phantom must be enough to simulate the attenuation and scattering characteristics of a human body or parts in a radiation field. The CT specific quantities : CT air kerma index (Ca,100) , weighted CT air kerma index (CW ), a total volume CT air kerma index (Cvol) and the CT air kerma-length product (PKL) must be determined and compared to literature reference levels. In this work a head pediatric phantom was developed, considering that the Brazilian published Diagnostic Reference Levels (DRL) are based on adult phantom measurements. This developed phantom shows a construction innovation using materials to simulate the skullcap, cortical bone (aluminum) and cancellous bone (PVC), and it was filled with distilled water. The phantom dimension follows the recommendations of the World Health Organization and the International Commission on Radiation Units for children from 0 to 5 years old head size: diameter of 160 mm and height of 155 mm. The skullcap has 4 mm of thickness and 111.9 mm of internal diameter. In order to evaluate its behavior, tests were carried out in calibration laboratories and in clinical beams. The results showed attenuation up to 23% when different materials are used as skullcap, demonstrating that the DRLs adopted could be overestimating the dose received by pediatric patients. It is observed that the dose received by CT skull scans presents different distribution, due to the skullcap partially attenuation and/or backscattering which is not considered when the PMMA phantom is used.

  3. In vivo thermoluminescent dosimetry in studies of helicoid computed tomography and excretory urogram; Dosimetria termoluminiscente In vivo en estudios de tomografia computada helicoidal y urograma excretor

    Cruz C, D.; Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Saucedo A, V.M.; Barajas O, J.L. [Unidad de Especialidades Medicas, Secretaria de la Defensa Nacional, 11500 Mexico D.F. (Mexico)

    2005-07-01

    The dosimetry is the field of measurement of the ionizing radiations. It final objective is to determine the 'absorbed dose' for people. The dosimetry is vital in the radiotherapy, the radiological protection and the treatment technologies by irradiation. Presently work, we develop 'In vivo' dosimetry, in exposed patients to studies of helical computed tomography and excretory urogram. The dosimetry 'in vivo' was carried out in 20 patients selected aleatorily, for each medical study. The absorbed dose was measured in points of interest located in crystalline, thyroid, chest and abdomen of each patient, by means of thermoluminescent dosemeters (TLD) LiF: Mg,Cu,P + Ptfe of national fabrication. Also it was quantified the dose in the working area. (Author)

  4. Characterization of chemical compounds for dosimetry of the radiation in industrial processes; Caracterizacao de compostos quimicos para dosimetria das radiacaoes em processos industriais

    Galante, Ana Maria Sisti

    1999-07-01

    Different chemical compounds have been studied to optimize dosimetric systems in irradiation processes. In this study 2,3,5 Triphenyl -2H- Tetrazolium Chloride, Brilliant Cresyl Blue, Bromocresol Green and Potassium Nitrate were investigated for their merits or faults, for {sup 60} Co gamma field, in order to verify if can be considered as dosimeters. Fricke solution was used as reference dosimeter to determine absorption dose rates at the gamma facilities.Only Bromocresol Green and Potassium Nitrate are recommended for dosimetry purposes since the main characteristics were achieved. The other two compounds could be used in dosimetry with changes in their formulation. Bromocresol Green and potassium Nitrate are reproducible and radiation sensitive for absorbed doses from 300 Gy to 150 kGy Bromocresol Green was used in liquid form and Potassium Nitrate was prepared in solid pellets form. Spectrophotometry in the visible region was used as the main detection technique, which allows relating optical absorption, before and after irradiation, with the absorbed dose. The maximum absorption wavelength for each compound was observed at 450-460nm for bromocresol Green and 546nm for Potassium Nitrate. Dose calibration curves are linear for both compounds in all dose intervals. When irradiated with accelerated electrons, with energies between o,9 MeV and 1,5MeV, optical absorption intensification, of about 2,6 times, was observed when comparing results for Potassium Nitrate, with those for gamma rays. All the evaluations are presented in this work. (author)

  5. Training of reverse propagation neural networks applied to neutron dosimetry; Entrenamiento de redes neuronales de propagacion inversa aplicadas a la dosimetria de neutrones

    Hernandez P, C. F.; Martinez B, M. R.; Leon P, A. A.; Espinoza G, J. G.; Castaneda M, V. H.; Solis S, L. O.; Castaneda M, R.; Ortiz R, M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Av. Ramon Lopez Velarde 801, Col. Centro, 98000 Zacatecas, Zac. (Mexico); Mendez V, R. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Laboratorio de Patrones Neutronicos, Av. Complutense 22, 28040 Madrid (Spain); Gallego, E. [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, ETSI Industriales, Jose Gutierrez Abascal 2, 28006 Madrid (Spain); De Sousa L, M. A. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Neutron dosimetry is of great importance in radiation protection as aims to provide dosimetric quantities to assess the magnitude of detrimental health effects due to exposure of neutron radiation. To quantify detriment to health is necessary to evaluate the dose received by the occupationally exposed personnel using different detection systems called dosimeters, which have very dependent responses to the energy distribution of neutrons. The neutron detection is a much more complex problem than the detection of charged particles, since it does not carry an electric charge, does not cause direct ionization and has a greater penetration power giving the possibility of interacting with matter in a different way. Because of this, various neutron detection systems have been developed, among which the Bonner spheres spectrometric system stands out due to the advantages that possesses, such as a wide range of energy, high sensitivity and easy operation. However, once obtained the counting rates, the problem lies in the neutron spectrum deconvolution, necessary for the calculation of the doses, using different mathematical methods such as Monte Carlo, maximum entropy, iterative methods among others, which present various difficulties that have motivated the development of new technologies. Nowadays, methods based on artificial intelligence technologies are being used to perform neutron dosimetry, mainly using the theory of artificial neural networks. In these new methods the need for spectrum reconstruction can be eliminated for the calculation of the doses. In this work an artificial neural network or reverse propagation was trained for the calculation of 15 equivalent doses from the counting rates of the Bonner spheres spectrometric system using a set of 7 spheres, one of 2 spheres and two of a single sphere of different sizes, testing different error values until finding the most appropriate. The optimum network topology was obtained through the robust design methodology of artificial neural networks where the parameters of the network that produced the best results were selected. (Author)

  6. Uncertainty analysis in the determination of absorbed dose in water by Fricke chemical dosimetry; Analise das incertezas na determinacao da dose absorvida na agua por dosimetria quimica Fricke

    Vasconcelos, Fabia; Aguirre, Eder Aguirre, E-mail: fabiavasco@hotmail.com, E-mail: ederuni01@gmail.com [Fundacao do Cancer, Rio de Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2016-07-01

    This work studies the calculations of uncertainties and the level of confidence that involves the process for obtaining the dose absorbed in water using the method of Fricke dosimetry, developed at Laboratorio de Ciencias Radiologicas (LCR). Measurements of absorbance of samples Fricke, irradiated and non-irradiated is going to use in order to calculate the respective sensitivity coefficients, along with the expressions of the calculation of Fricke dose and the absorbed dose in water. Those expressions are used for calculating the others sensitivity coefficients from the input variable. It is going to use the combined uncertainty and the expanded uncertainty, with a level of confidence of 95.45%, in order to report the uncertainties of the measurement. (author)

  7. A new computation tool for neutron spectrometry and dosimetry; Una nueva herramiento de computo para la espectrometria y dosimetria de neutrones

    Martinez B, M. R.; Ortiz R, J. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Av. Ramon Lopez Velarde No. 801, Col. Centro, Zacatecas (Mexico)], e-mail: mrosariomb@yahoo.com.mx

    2009-10-15

    By using the integrated accounts of spectrometric system of Bonner spheres is possible to reconstruct the neutron spectrum using various methods such as: Monte Carlo, the parameterization and iterative methods. The response matrix, counting rates and neutron spectrum are intimately related through the integral-differential of Fredholm of first type. however, the weight of Bonner spheres system, the procedure of spectra reconstruction, the need of a expert user, the high time consumption, the need to use a reconstruction code (BUNKI, SAND, among others) and the spectrum resolution, are some of problems that this system presents. The above difficulties have motivated the development of complementary procedures such as maximum entropy, genetic algorithms and artificial neural networks. In recent years, using neural network technology has become an alternative procedure in the nuclear science research area, considering a replacement for classical techniques used for years. In previous works, was used a new method called robust design methodology of artificial neural networks, to construct various network topologies capable of solving the problems of neutron spectrometry and dosimetry, however noted that not exist tools for end-user that allow test and validate the designed networks. This paper presents the development of a software for neutronic spectrometry and dosimetry, based on information extracted from an artificial neural network designed in previous work, through the robust design methodology of artificial neural networks with the following characteristics: was designed in a user graphical interface easy to use, speed on the application execution, unlike other deconvolution codes, not is necessary to select and initial spectrum for spectrum reconstruction, as an additional element to this tool, besides spectrum, the calculation is performed simultaneous of 13 equivalent dose from just counting rates from a spectrometric system of Bonner spheres. (Author)

  8. Biological dosimetry after criticality accidents. Intercomparison exercise in the Silene Reactor - France; Dosimetria biologica en accidentes de criticidad. Ejercicio de intercomparacion en el Reactor Silene - Francia

    Di Giorgio, Marina; Vallerga, Maria B; Taja, Maria R [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); arn gov ar, E-mail: mdigiorg@cae

    2004-07-01

    The Institute of Radiation Protection and Nuclear Safety Institute (IRSN) organized an international biological dosimetry intercomparison, at the SILENE experimental reactor (Valduc, France), simulating different criticality scenarios: bare source 4 Gy, lead shield source 1 and 2 Gy and gamma pure {sup 60}Co source 2 Gy. Fifteen laboratories were involved in this exercise, including the Argentine Biological Dosimetry Laboratory. The purposes of the intercomparison were: 1) To compare the unstable chromosome aberration (UCA) frequency observed by the different laboratories; and 2) To compare the dose estimation for gamma rays and neutrons. The objects of the present work were: I) To compare the mean frequency of UCA observed by the Argentine laboratory with the mean frequency observed by the participant laboratories as a whole. II) To compare the dose estimates performed by the Argentine lab with those estimated by the other laboratories involved in the second stage of the intercomparison. Overall, the mean frequencies of UCA and the correspondent 95% confidence limits obtained by the Argentine lab were consistent with the results obtained by the laboratories as a whole. For the gamma pure scenario, smaller variations were observed among laboratories in terms of dose (CV=18,2%) than in terms of frequency (CV=30,1%). For the mixed field scenarios, only four laboratories, including the Argentine lab, estimated gamma and neutron components of the total dose and just two (Argentine lab and lab 12) were in agreement with the given physical doses. The 1 Gy experiment presented lesser variations both in terms of frequency and dose than the other two scenarios. For the 4 and 2 Gy experiments, variations in neutron dose were more significant than variations in gamma dose, related to the magnitude of the dose. The results suggest that intercomparison exercises jointly with the accreditation of biological dosimetry by cytogenetic service laboratories, in compliance with ISO/IEC 17025, would allow to unify the protocols applied regarding: techniques, metaphase selection and scoring process. Thus, the dosimetric response in accidental overexposures that would require cooperation among countries, will be improved. (author)

  9. Production of LiF films for dosimetric thermoluminescence application; Producao de filmes de LiF para aplicacao em dosimetria termoluminescente

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F{sub 2} NaF and Cu F{sub 2} to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a {sup 60} Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F{sub 2}: LiF; Mg F{sub 2} films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F{sub 2} : LiF: Mg F{sub 2} films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F{sub 2} layer to the LiF layer. The TL volumetric sensitivity of these films is about four times that of LiF powder and about 1% that of TLD 100. The homogeneity and reproducibility inside a same film batch is better than 20% for 95% of confidence level. (author)

  10. Neutron spectrometry and dosimetry by means of evolutive neural networks; Espectrometria y dosimetria de neutrones por medio de redes neuronales evolutivas

    Ortiz R, J.M.; Martinez B, M.R.; Vega C, H.R. [UAZ, Av. Ramon Lopez Velarde Num. 801, 98000 Zacatecas (Mexico)

    2008-07-01

    The artificial neural networks and the genetic algorithms are two relatively new areas of research, which have been subject to a growing interest during the last years. Both models are inspired by the nature, however, the neural networks are interested in the learning of a single individual, which is defined as fenotypic learning, while the evolutionary algorithms are interested in the adaptation of a population to a changing environment, that which is defined as genotypic learning. Recently, the use of the technology of neural networks has been applied with success in the area of the nuclear sciences, mainly in the areas of neutron spectrometry and dosimetry. The structure (network topology), as well as the learning parameters of a neural network, are factors that contribute in a significant way with the acting of the same one, however, it has been observed that the investigators in this area, carry out the selection of the network parameters through the essay and error technique, that which produces neural networks of poor performance and low generalization capacity. From the revised sources, it has been observed that the use of the evolutionary algorithms, seen as search techniques, it has allowed him to be possible to evolve and to optimize different properties of the neural networks, just as the initialization of the synaptic weights, the network architecture or the training algorithms without the human intervention. The objective of the present work is focused in analyzing the intersection of the neural networks and the evolutionary algorithms, analyzing like it is that the same ones can be used to help in the design processes and training of a neural network, this is, in the good selection of the structural parameters and of network learning, improving its generalization capacity, in such way that the same one is able to reconstruct in an efficient way neutron spectra and to calculate equivalent doses starting from the counting rates of a Bonner sphere spectrometric system. (Author)

  11. Thermoluminescent dosimetry of new phosphors of Zn O exposed to beta radiation; Dosimetria termoluminiscente de nuevos fosforos de ZnO expuestos a radiacion beta

    Cruz V, C.; Burruel I, S.E.; Grijalva M, H. [UNISON, A.P. 130, Hermosillo, Sonora (Mexico); Barboza F, M.; Bernal, R. [CIF, UNISON, A.P. 5-088, Hermosillo, Sonora (Mexico)

    2004-07-01

    In this work, we report the thermoluminescence dosimetry of a new Zn O phosphor obtained by annealing of Zn S powder precipitated when Zn S films were grown by employing a CBD method. The collected Zn S powder was pressed in a die to form pellets which were subjected to different thermal treatments under air atmosphere. X-ray diffraction (XRD) patterns and energy-dispersive X-ray Spectrometry (EDS) analyses confirmed the transformation of Zn S to Zn O. The phosphors thus obtained were exposed to high doses of beta radiation and their thermoluminescent dosimetry show that these new phosphors are materials suitable to be used in high dose thermoluminescence dosimetry. (Author)

  12. The Pelletron Accelerator of IFUNAM and its possible applications to the dosimetry; El Acelerador Pelletron del IFUNAM y sus posibles aplicaciones a la dosimetria

    Rickards, J. [Instituto de Fisica, UNAM, Circuito Exterior, C.U. 04510 Mexico D.F. (Mexico)

    1999-07-01

    The Pelletron Accelerator of positive ions 3 MV in the Institute of Physics of UNAM has characteristics that make it useful for the application to the radiations dosimetry. It is ideal for studying the detailed mechanisms of the radiation interaction with matter, therefore it can be applied to know the performance of dosemeters. With this device can be accelerated almost any type of ion, including He, but excepting the others noble gases. The energies of the disposable ions are in the interval 1 MeV until several MeV, depending of the state of charge selected, the energy can be varied continuously with accuracy of some KeV. It can be achieved streams from 10{sup 4} until 10{sup 6} ions/cm{sup 2}, allowing studies of individual events (tracks) or of collective processes. the beam size can be varying from a diameter 1 mm until 5 cm. It is also took in account with detectors and other techniques associated that can be combined for supporting studies, as surface barrier detectors and of other types, as well as the RBS, PIXE, RN techniques and channeling. (Author)

  13. Dosimetry through the Secondary Laboratory of Dosimetric Calibration of Mexico; Dosimetria a traves del Laboratorio Secundario de Calibracion Dosimetrica de Mexico

    Tovar M, V.M.; Alvarez R, J.T.; Medina O, V.P.; Vergara M, F.; Anaya M, R.; Cejudo A, J.; Salinas L, B. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2004-07-01

    In the beginnings of the sixty years an urgent necessity is presented mainly in the developing countries, of improving in important form the accuracy in the dosimetry of external faces in therapy of radiations (radiotherapy centers), mainly in the calibration of ''clinical dosemeters''. In 1976 the International Atomic Energy Agency, (IAEA), and the World Health Organization, (WHO), they carried out a mutual agreement with regard to the establishment and operation of a net of Secondary Patron Laboratories of Dosimetry, (LSCD). The necessity to establish measure patterns in the field of the dosimetry of the ionizing radiations, is necessary, to have an accuracy but high in the dosimetry of the radiation beams in therapy which is highly dependent of the dose given to the tumor of those patient with cancer. Similar levels of accuracy are required in protection measures to the radiation with an acceptable smaller accuracy, however, when the personal dosemeters are used to determine the doses received by the individuals under work conditions, such mensurations in therapy of radiations and radiological protection will have traceability through a chain of comparisons to primary or national patterns. The traceability is necessary to assure the accuracy and acceptability of the dosimetric measures, as well as, the legal and economic implications. The traceability is also necessary in the dosimetry of high dose like in the sterilization of different products. The main function of the LSCD is to provide a service in metrology of ionizing radiations, maintaining the secondary or national patterns, which have a traceability to the International System of measures, which is based for if same in the comparison of patterns in the Primary Laboratories of Dosimetry (LPD) under the auspice of the International Office of Weights and Measure (BIPM). The secondary and national patterns in the LSCD constitute in Mexico, the national patterns of the magnitudes in the dosimetry of the ionizing radiations. The net of the LSCD of the IAEA/WHO counts the international support to promote the objectives of improving the accuracy in dosimetry measures, particularly in radiotherapy centers, radiological protection and irradiation of different products, as well as, to transfer the dosimetric magnitudes and the distribution of the knowledge in applied dosimetry. The net of LSCD of the IAEA has 69 laboratories in the world in 58 states affiliated members, 13 primary laboratories (Germany, Australia, Austria, Canada, France, Hungary, Italy, Japan, Holland, Russia, United Kingdom, United States), 5 international organizations (ICRU, BIPM, IOMP, IEC, IOML). The first Standard Regional Center of Calibration and Dosimetry in Mexico settled down in the year of 1974 in the Department of Radiotherapy of the Hospital General of Mexico of the Secretary of Health SSA of Mexico. It was working until the year of 1985 when an earthquake in Mexico City destroys great part of its infrastructure. Later on in the year of 1986, the Standard Regional Center of Calibration and Dosimetry, for agreement of the SSA and of the National Institute of Nuclear Research, ININ, step to the Department of Metrology of the ININ. (Author)

  14. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  15. TL Dosimetry on the Tandetron Ion Accelerator area of the ININ; Dosimetria TL en el area del Acelerador de iones Tandetron del ININ

    Valdovinos A, M.A.; Gonzalez M, P.R. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    For the fulfilment of the operation tests of the Positive Ions type Tandetron 4120 MC, 2 MV, it was obtained the permission consented by the National Commission of Nuclear safety and safeguards (CNSNS). During the stage of tests were arranged Tl dosemeters in the Tandetron Accelerator area, as well as toward to the beam exit. In this work, it was presented the results obtained of the measurement of radiation levels, as much in the area as in the beam exit. This Accelerator is useful in different fields of science such as: biology, radiochemistry, materials, solid state physics, archaeology and environmental sciences between others. (Author)

  16. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  17. Development and implementation of own software for dosimetry multichannel film; Desarrollo e implementacion de un software propio para la dosimetria multicanal con pelicula radiocromica EBT2

    Jimenez Feltstrom, D.; Reyes Garcia, R.; Luis Simon, F. J.; Carrasco Herrera, M.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-07-01

    The objective of this work is to develop its own software for multichannel film dosimetry Radiochromic EBT2. Compare the results obtained with its use in multichannel and single-channel dosimetry. Check that the multi-channel dosimetry eliminates much of the artifacts caused by dirt, fingerprints, scratches, etc. Radiochromic in film and scanner devices. (Author)

  18. Experimental verification of a new neutron spectrometer for environmental dosimetry and area; Verficiacion experimental de un nuevo espectrometro de neutrones para dosimetria ambiental y de area

    Gomez-Ros, J. M.; Romero, A.; Begogini, R.; Esposito, A.; Moraleda, M.; Lagares, J. I.; Sansaloni, F.; Arce, P.; Llop, J.

    2011-07-01

    In this communication, we present experimental results with a new neutron spectrometer, developed jointly by the Radiation Dosimetry Unit of CIEMAT Unita di Fisica and INFN-LNF Sanitary (Italy), consisting of a polyethylene moderating sphere detectors thermal neutrons (paired thermoluminescent dosimeters and activation foils) located in different positions. The device configuration and distribution of dosimeters are designed to elicit a response in a nearly isotropic up to 20 MeV energy range. (Author)

  19. Determination of effective dose for workers hemodynamics service using double dosimetry; Determinacion de la dosis efectiva para los trabajadores del servicio de hemodinamica usando doble dosimetria

    Ruiz Lopez, M. A.; Lobato Munoz, M.; Jodar Lopez, C. A.; Ramirez Ros, J. C.; Jerez Sainz, M. I.; Pamos Urena, M.; Carrasco Rodriguez, J. L.

    2013-07-01

    The use of an additional dosimeter at the level of the neck above the lead apron we can provide an indication of the dose in the head (the Crystal dose). In addition, it is possible to combine the two readings of the dosimeter to provide an improved estimate of the effective dose. In the hemodynamics service of our Hospital we have maintained a worker for 3 years with the double dosimetry read monthly. With the readings from these dosimeters will do following algorithms, several estimates of the effective dose to see if, with working conditions that occur in this service, it would be necessary to extend this practice to the rest of the workers to get a better estimation of effective dose. (Author)

  20. Experience of the new service of dosimetry internal by Bio elimination of Tecnatom; Experiencia del nuevo servicio de dosimetria interna por bioeliminacion de Tecnatom

    Duran, T.; Navas Menchen, C.; Campos Mendia, J.

    2012-07-01

    Internal dosimetry is of particular relevance for occupationally exposed workers in the field of nuclear decommissioning and radioactive facilities. The tasks to be performed at these facilities involve an increase in the risk of incorporation of radioactive material into the body, the radioactive waste generated diverse in nature and involve work that may lead to a greater dispersion of radioactive material.

  1. ISO 9001 certification in the clinical dosimetry process in physics medical service; Certificacion ISO9001 en el proceso de dosimetria clinica en un servicio de fisica medica

    Font Gomez, J. A.; Andres Redondo, M. M.; Gandia Martinez, A.; Jimenez Albericio, F. J.; Mengual Gil, M. A.

    2013-07-01

    The objective of this work is to simply name a series of procedures that are part of the certification and technical instructions (manuals about how to perform specific tasks) without going into details. (Author)

  2. Development of pathological anthropomorphic models using 3D modelling techniques for numerical dosimetry; Desenvolvimento de modelos antropomorficos patologicos usando tecnicas de modelagem 3D para dosimetria numerica

    Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco, Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-10-26

    Computational exposure models can be used to estimate human body absorbed dose in a series of situations such as X-Ray exams for diagnosis, accidents and medical treatments. These models are fundamentally composed of an anthropomorphic simulator (phantom), an algorithm that simulates a radioactive source and a Monte Carlo Code. The accuracy of data obtained in the simulation is strongly connected to the adequacy of such simulation to the real situation. The phantoms are one of the key factors for the researcher manipulation. They are generally developed in supine position and its anatomy is patronized by compiled data from international institutions such as ICRP or ICRU. Several pathologies modify the structure of organs and body tissues. In order to measure how significant these alterations are, an anthropomorphic model was developed for this study: patient mastectomies. This model was developed using voxel phantom FASH and then coupled with EGSnrc Monte Carlo code

  3. Biological dosimetry of ionizing radiation by chromosomal aberration analysis; Dosimetria biologica de las radiaciones ionizantes mediante el analisis de aberraciones cromosomicas

    Gonzalez-Castano, S.; Silva, A.; Navlet, J.

    1990-07-01

    Biological dosimetry consists of estimating absorbed doses for people exposed to radiation by mean biological methods. Several indicators used are based in haematological, biochemical, and cytogenetic data, although nowadays without doubt, the cytogenetic method is considered to be the most reliable. In this case, the study ol chromosomal aberrations, normally dicentric chromosomes, in peripheral lymphocytes can be related to absorbed dose through an experimental calibration curve. An experimental dose-response curve, using dicentric chromosomes analysis, X-rays at 300 kVp, 114 rad/min and temperature 37 degree celsius has been produced. Experimental data is fitted to model Y ={alpha} + {beta}{sub 1}D + {beta}{sub 2}D 2 , where Y is the number of dicentrics per cell and D the dose. The curve is compared with those produced elsewhere. (Author) 14 refs.

  4. EPR response characterization of drugs excipients for applying in accident dosimetry; Caracterizacao da resposta RPE dos excipientes dos medicamentos para aplicacao em dosimetria de acidente

    Marczewski, Barbara S.; Rodrigues Junior, Orlando; Galante, Ocimar L.; Costa, Zelia M. da; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    Some drugs are widely used by the population and can be employed to dose retrospective. The carbohydrates (saccharides), commonly used as excipients in the pharmaceutical industry, produce a quantity of free radicals after gamma irradiation, making them useful for dosimetry in emergency or accident situations that imply in dose evaluation from the materials found nearly or in contact with victims. In general, EPR signal from pulverized pills of some drugs are very complex due to the variety of components in the formulation. Because of this fact, some pharmaceutical excipients identified in the pill composition were also analysed by EPR spectrometry. On the counter drugs were studied: Cebion glucose, AAS, Aspirina, Conmel, Lacto-Purga and sugar substitutive ZeroCal. The excipients were: lactose, amide, anhydrous glucose and magnesium stearate. In some samples the number of radicals produced increased with the dose, showing a linear response for a dose range of interest and an adequate sensibility for dosimetry in accident cases.

  5. Use of Fricke solution modified with dyes for dosimetry in phototherapeutic treatments; Uso da solucao Fricke modificada com corantes para futura dosimetria em tratamentos fototerapeuticos

    Almeida, Mayara Gabriella Oliveira de; Nascimento, Rizia Keila; Vieira, Rafaela Etelvina de Amorim; Souza, Vivianne Lucia Bormann, E-mail: mayaradqf@hotmail.com, E-mail: riziakeila@hotmail.com, E-mail: rafaelarodriguesss@hotmail.com, E-mail: vlsouza@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife (Brazil)

    2014-07-01

    Dyes and pigments (photosensitizers) are characterized by their ability to absorb visible light, and to participate in photochemical reactions. These colors are used in medicine in the dose recommended for use in photodynamic therapy (PDT). There are lasers that can meet most of the phototherapeutic agents and are capable of providing light of considerable power with precision on the injured tissue. The use of light emitting diodes (LEDs) have become feasible, thus reducing the cost of the procedures. The Dosimetry Laboratory Chemistry of the CRCN-NE/Brazilian CNEN has worked with some likely dye use in phototherapy treatments, including: methylene blue, malachite green and toluidine blue. A volume of 2.6 ml of the dosimeters was transferred to test tubes and these were irradiated with LED 24, 48, 72 and 96 acrylic simulator 110 mm x 110 mm x 80 mm at a distance of 6.5 cm from reading light source of the irradiated samples was performed on a spectrophotometer. Having obtaining excellent correlations (above 0.97) to the dosimeter calibration curves. Suggests that the dosimeter can be applied to perform a quality control in photodynamic therapy. However, further experiments should be performed before a wide application of this technique. A volume of 2.6 ml of the dosimeters was transferred to test tubes and these were irradiated with LED 24, 48, 72 and 96 acrylic simulator 110 mm x 110 mm x 80 mm at a distance of 6.5 cm from reading light source of the irradiated samples was performed on a spectrophotometer. Having obtaining excellent correlations (above 0.97) to the dosimeter calibration curves. Suggests that the dosimeter can be applied to perform a quality control in photodynamic therapy. However, further experiments should be performed before a wide application of this technique.

  6. Dosimetry for the treatment of cystic craniopharyngioma through radiocolloids with {sup 186} Re; Dosimetria para el tratamiento de craneofaringiomas quisticos mediante radiocoloide con {sup 186} Re

    Rojas, E.L.; Al-dweri, F.M.O.; Lallena, A.M. [Depto. de Fisica Moderna, Universidad de Granada (Spain); Bodineau, C.; Galan, P. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' Carlos Haya' , 29010 Malaga (Spain)

    2003-07-01

    The cystic craniopharyngioma (CQ) are histologically benign tumors that can affect important organs, as the hypothalamus or the optic nerve. They are treated introducing, inside the cyst, a radioactive colloid. The wall constitutes the white volume and the dosimetry is usually carried out starting from analytic formulas that only are valid in the case of an homogeneous media, uniform and infinite. In this work it is studied the dosimetry of the CQ by means of Monte Carlo simulation (MC), taking in account the different materials and interfaces that conform them. We present the obtained results for the radionuclide {sup 186} Re. We have used the Monte Carlo code Penelope and we follow 5x10{sup 6} histories in each simulation. We supposed a size of CQ of 1.75 cm of radio and a wall thickness of 1 mm and we have varied the constituent materials of the interior of the cyst and of the wall. The analytic calculations that we carry out show an excellent agreement with the MC results for an unique media (water), as much for the beta radiation as for those originated of the Rhenium disintegration. However, when it takes in account the gel that is introduced in the tumor for the treatment and we vary the constituent material of the wall, we find important differences. Of the analysis of our results we can conclude that the dosimetry for the treatment of CQ based in the usual analytic formulas overestimates the doses really deposited in the wall of the CQ. (Author)

  7. Test and validation of the iterative code for the neutrons spectrometry and dosimetry: NSDUAZ; Prueba y validacion del codigo iterativo para la espectrometria y dosimetria de neutrones: NSDUAZ

    Reyes H, A.; Ortiz R, J. M.; Reyes A, A.; Castaneda M, R.; Solis S, L. O.; Vega C, H. R., E-mail: alfredo_reyesh@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, Av. Lopez Velarde 801, Col. Centro, 98000 Zacatecas (Mexico)

    2014-08-15

    In this work was realized the test and validation of an iterative code for neutronic spectrometry known as Neutron Spectrometry and Dosimetry of the Universidad Autonoma de Zacatecas (NSDUAZ). This code was designed in a user graph interface, friendly and intuitive in the environment programming of LabVIEW using the iterative algorithm known as SPUNIT. The main characteristics of the program are: the automatic selection of the initial spectrum starting from the neutrons spectra catalog compiled by the International Atomic Energy Agency, the possibility to generate a report in HTML format that shows in graph and numeric way the neutrons flowing and calculates the ambient dose equivalent with base to this. To prove the designed code, the count rates of a spectrometer system of Bonner spheres were used with a detector of {sup 6}LiI(Eu) with 7 polyethylene spheres with diameter of 0, 2, 3, 5, 8, 10 and 12. The count rates measured with two neutron sources: {sup 252}Cf and {sup 239}PuBe were used to validate the code, the obtained results were compared against those obtained using the BUNKIUT code. We find that the reconstructed spectra present an error that is inside the limit reported in the literature that oscillates around 15%. Therefore, it was concluded that the designed code presents similar results to those techniques used at the present time. (Author)

  8. Characterization of silicates and calcium carbonates applied to high-dose dosimetry; Caracterizacao de silicatos e carbonatos de calcio aplicados a dosimetria de doses altas

    Vila, Gustavo Barreto

    2012-07-01

    The predominant isomorphous form in the biominerals studied in this work (oyster shell, coral, mother of pearl and shell) was aragonite. The appearance of the calcite phase occurred at 500 deg C at a heating rate of 10 deg {sup C}/s for all samples except for the coral sample, which was 400 deg C, independent of the heating rate. The most abundant element in the biominerals samples was Ca in the CaO form, and in the silicates (tremolite, diopside and rhodonite) Si in the SiO form. The most common trace element observed in the biominerals samples was Fe. The analyses of electron paramagnetic resonance showed lines of Mn{sup 2+} in the coral and mother-of-pearl samples before irradiation. In the case of the irradiated samples, the defects found were CO{sub 2}{sup -}, CO{sub 3}{sup 3-}, CO{sub 3}{sup -} and SO{sub 2}{sup -}, in the g range between 2.0010 and 2.0062. In the analyses by optical absorption of biominerals, transitions due to the presence of Mn in the samples were found. A thermoluminescent (TL) peak at approximately 140 deg C was found for the biominerals and at 180 deg C for silicates, which intensity depends directly on the dose. For samples exposed to different types of radiation, the TL peak occurred at lower temperatures. From the dose-response curves obtained for these materials, it was possible to determine a linear range for which their application in high dose dosimetry becomes possible. Taking into account the radiation type, among biominerals and silicates, the lowest detectable dose (40mGy) to gamma radiation was achieved for oyster shell samples using the measuring technique of optically stimulated luminescence (OSL). Using beta radiation, for diopside and tremolite samples the lowest detectable dose of 60mGy was obtained. For all samples, using the TL, OSL and thermally stimulated exoelectron emission (TSEE) techniques in alpha, beta and gamma radiation beans a good response reproducibility was obtained. Therefore, the samples characterized in this work are suitable to be used as high dose detectors/dosimeters. (author)

  9. Quality control of radiosurgery: dosimetry with micro camera in spherical mannequin; Control de calidad en radiocirugia: dosimetria con microcamara en maniqui esferico

    Casado Villalon, F. J.; Navarro Guirado, F.; Garci Pareja, S.; Benitez Villegas, E. M.; Galan Montenegro, P.; Moreno Saiz, C.

    2013-07-01

    The dosimetry of small field is part of quality control in the treatment of cranial radiosurgery. In this work the results of absorbed dose in the isocenter, Planner, with those obtained from are compared experimentally with a micro-camera into an spherical mannequin. (Author)

  10. Internal dosimetry for [4-{sup 14}C]-cholesterol in humans; Dosimetria interna para o [4-{sup 14}C]-colesterol em humanos

    Marcato, Larissa Andreto

    2012-07-01

    The main objective of this work is to provide a biokinetic model in order to estimate the radiometric dose due to intake of [4-{sup 14}C]-cholesterol. The model was validated comparing the values of fecal excretion and absorption described in literature with that predicted by the model. The proposed model achieved good concordance between the results (p = 0.416 for excretion and p = 0.423 for absorption). The coefficients of effective dose (SvBq{sup -1}), equivalent dose (SvBq{sup -1}) and absorbed dose (GyBq{sup -1}) in human organs and tissues were calculated using the MIRD methodology and the compartmental analysis software ANACOMP. The coefficients were estimated for four phantoms: adult with a body mass of 73.3 kg, 15 years old adolescent (56.9 kg), 10 years old child (33.2 kg) and five years old child (19.8 kg). The organ that received the highest absorbed dose for all phantoms was the lower large intestine (LLI). The allometry theory was used to interpolate the coefficient of absorbed dose in the lower large intestine (DLLI) for unknown body mass (m): DLLI (GyBq{sup -1})=161.26 m (kg){sup -1.025}. For the same administered activity, the effective dose coefficient (E) decreases as the body mass increases. On other words, for the same intake activity, individuals with low body mass are exposed to higher doses. The allometry theory was used to interpolate the coefficient effective dose (E) for unknown body mass (m): E(SvB{sup -1})= 171.1 m(kg){sup -1,021}. (author)

  11. Dosimetria comparativa de braquiterapia de próstata com sementes de I-125 e Pd-103 via SISCODES/MCNP

    Trindade, Bruno Machado; Christóvão, Marília Tavares; Trindade, Daniela de Fátima Maia; Falcão, Patrícia Lima; Campos, Tarcisio Passos Ribeiro de

    2012-01-01

    OBJETIVO: O presente artigo visa apresentar um estudo dosimétrico comparativo de braquiterapia de próstata com sementes de I-125 e Pd-103. MATERIAIS E MÉTODOS: Um protocolo adotado para ambos os implantes com 148 sementes foi simulado em um fantoma tridimensional heterogêneo de pelve por meio dos códigos SISCODES/MCNP5. Histogramas dose-volume na próstata, bexiga e reto, índices de doses D10, D30, D90, D0,5cc, D2cc e D7cc, e representações de distribuição espacial de dose foram avaliados. RES...

  12. TLD personnel dosimetry and its relationship with the radiodiagnostic training; Dosimetria personal TLD y su relacion con la capacitacion en radiodiagnostico

    Gaona, E.; Franco E, J.G. [DEHA, Universidad Autonoma Metropolitana-Xochimilco, Mexico D.F. (Mexico); Gaona C, E. [Universidad Tecnologica de Mexico, Mexico D.F. (Mexico)

    2002-07-01

    The personnel dosimetry and the training in radiological protection in radiodiagnostic in Mexico before 1997 were almost nonexistent except few services of public and private radiology, we can to say that the personnel dosimetry and the obligatory training was born in the year 1997, together with the present Mexican Official Standards in radiology. This study has the purpose to make an evaluation of the personnel dosimetry of 110 radiology services distributed in the Mexican Republic for the year 2001 and to estimate the annual and bimonthly mean doses, as well as its trust intervals and its relationships with the personnel training in radiological protection by means of a sampling that was realized in two stages (1997 and 2000) in the metropolitan area of Mexico City. The results show that the received doses by the medical and technical personnel in the participating radiology services are in the 0.03 mSv and 0.94 mSv interval and the mean is 0.25 mSv. The estimated annual personnel dose would be in the 0.18 mSv to 5.64 mSv interval, which are values very lower to the annual dose limit that is 50 mSv and its magnitude is similar to the effective annual dose by natural background radiation. In the first stage in training was found that there is not a significant difference in the response frequencies among the medical and technical personnel with a p < 0.05. The 52% of the occupational exposure personnel of radiology uses dosemeter, but only 17% of them know the dose reports. the 15.8% of personnel considers that dosemeter protects against radiation and only 16.5% knows the annual maximum permissible dose for stochastic effects. The second stage, the results shown that there is a significant difference in the response of frequencies among medical and technical personnel, the same results which are obtained for members and non members of a professional association with a p < 0.05. The 38% has personnel dosimetry, the 19% knows the principles of radiological protection. (Author)

  13. Determination of the components of uncertainty for a dosimetry system in radiation protection; Determinacion de las componentes de incertidumbre para un sistema de dosimetria en radio proteccion

    Lopez, F., E-mail: flopez@unan.edu.ni [Universidad Nacional Autonoma de Nicaragua, Managua (Nicaragua); Cabral, T.S.; Peixoto, J.G. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    This work is about the theoretical calculation of uncertainties associated to the dosimetry of photons of a {sup 137}Cs source that will be used in a Dosimetry Laboratory. In this case recognition of the influence quantities that provide most uncertainty and the right choice of resolution of auxiliary equipment to obtain the smallest uncertainties according to the laboratory. (author)

  14. Accreditation of a system of extremity dosimetry: validation and uncertainty of method; Acreditacion de un sistema de dosimetria de extremidades: validacion e incertidumbre del metodo

    Romero Gutierrez, A. M.; Rodriguez Jimenez, R.; Lopez Moyano, J. L.

    2013-07-01

    The authors' goal is to spread the practical experience gained during the accreditation process paying special attention to the process of method validation and estimation uncertainty of the dosimetry system. (Author)

  15. Dosimetry for computed tomography using Fricke gel dosimetry and magnetic resonance imaging; Dosimetria em tomografia computadorizada empregando dosimetro Fricke gel e a tecnica de imageamento por ressonancia magnetica

    Capeleti, Felipe Favaro; Campos, Leticia L., E-mail: felipe@gmpbrasil.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-04-15

    In this work it was determined a new method for the determination of absorbed doses in Computed Tomography (CT) examinations using Fricke gel dosimetry developed at IPEN. Absorbed doses were determined by different methods of analysis, such as optical absorption spectrometry, ionization chambers and magnetic resonance imaging. Lower limit of sensitivity of the Fricke gel solution, the solution repeatability signal Fricke gel and CT equipment, detection sensitivity, among other tests were performed. Different equipment of computed tomography with multiple detectors were used. The Fricke gel solution showed better repeatability than ±5.5% using the technique of optical absorption spectrophotometry and computed tomography equipment showed repeatability better than ±0.2%. The Fricke gel solution features an easy and relatively quick preparation, but it is necessary to be careful not to contaminate and lose the solution. With the results, it was confirmed the application of this type of dosimetry for computed tomography equipment. (author)

  16. Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons

    Bulla, Roseli Tadeu

    1999-07-01

    The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

  17. Spectrometry and dosimetry of isotopic sources of neutrons by means of artificial neural networks; Espectrometria y dosimetria de fuentes isotopicas de neutrones mediante redes neuronales artificiales

    Vega C, H. R.; Ortiz R, J. M.; Hernandez D, V. M; Martinez B, M. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, C/Jose Gutierrez Abascal No. 2, 28006 Madrid (Spain); Barquero, R., E-mail: fermineutron@yahoo.co [Hospital del Rio Hortega, C/Dulzaina No. 2, 47012 Valladolid (Spain)

    2010-09-15

    The artificial neural networks technology has been applied to reconstruct the neutrons spectra of two isotopic sources: {sup 252}Cf, and {sup 241}Am-Be. Also, this technology has been applied to obtain the effective dose, E, and the personal dose equivalents, Hp(10) and environmental, H *(10). To obtain the spectra and the doses only were used the count rates produced in a Bonner Spheres spectrometer with a scintillator of {sup 6}LiI(Eu) of 0.4 {phi} x 0.4 cm{sup 2}. The equivalent environmental dose and the spectra of the sources were also obtained by means of the reconstruction code BUNKIUT. When comparing the results obtained by means of both procedures it was found that they are consistent. (Author)

  18. Monte Carlo dosimetry in simple geometries with interfaces: applications in radiotherapy; Dosimetria Monte Carlo en geometrias simples con interfases: aplicaciones en radioterapia

    Rojas C, E.L

    2004-07-01

    In the last decade, dosimetry has evolved in an accelerated way due in part, to the development of new techniques and advances in instruments manufactured for several applications in Medical Physics. In order to improve achievements gotten with the use of radiation sources for therapeutic use, a guessed right dosimetry must be done and clinical data must be explained with the aid of investigation and supported with scientific bases. In this context, Monte Carlo (MC) method used to simulate radiation transport in materials, contribute with extensive knowledge and extremely useful information to that objective. MC dosimetry has some advantages over experimental and analytical dosimetry but it also has limitations. Maybe the most important is the computer time required to reach to an acceptable uncertainty level in a complex problem. Though this restrictive factor, a right application of MC simulation of radiation transport is a useful, reliable and versatile instrument for dosimetric calculations. From our point of view, the problem of heterogeneities in the sources or in the treatment targets in radiotherapy is of great importance, and this is the principal question to study aboard in this work. We use the MC simulation code Penelope to calculate some dosimetric quantities.The cases we study involve dosimetric aspects of different geometric distributions of radionuclides where interfaces are evident and must be taken into account. This work is divided in five chapters. In the first chapter we give a succinctly description of MC codes for simulation of the transport of particles in a medium and we describe the code Penelope. In chapter two, we study spherical distributions of radionuclides and the effect that interfaces in the target have in the dose received by the tumor. Specifically we study the application of radiocolloids with {sup 186} Re and {sup 32} P to treat homogeneous and nonhomogeneous cystic craniopharyngioma. Chapter three is dedicated to study plane distributions of radionuclides in presence of interfaces, particularly we deal with the injection of radiocolloids with {sup 165} Dy, {sup 32} P and {sup 90} Y into the knee joint with different healing purposes. The model is described and similar studies to those of chapter two, involving heterogeneities of the joint are presented. In chapter four, dosimetric studies of simulated treatments of radiosurgery of the head with the Leksell Gamma Knife are done. We describe the unit, give the simulation details and parameters and describe the targets. To make our investigation spheric interfaces of different materials in the phantoms are considered. Finally, a chapter with the conclusions is presented. References are given after this chapter. (Author)

  19. Dosimetria comparativa de braquiterapia de próstata com sementes de I-125 e Pd-103 via SISCODES/MCNP

    Bruno Machado Trindade

    2012-10-01

    Full Text Available OBJETIVO: O presente artigo visa apresentar um estudo dosimétrico comparativo de braquiterapia de próstata com sementes de I-125 e Pd-103. MATERIAIS E MÉTODOS: Um protocolo adotado para ambos os implantes com 148 sementes foi simulado em um fantoma tridimensional heterogêneo de pelve por meio dos códigos SISCODES/MCNP5. Histogramas dose-volume na próstata, bexiga e reto, índices de doses D10, D30, D90, D0,5cc, D2cc e D7cc, e representações de distribuição espacial de dose foram avaliados. RESULTADOS: A atividade inicial de cada semente de I-125, para que D90 seja equivalente à dose de prescrição, foi calculada em 0,42 mCi, e de Pd-103, em 0,94 mCi. A dose máxima na uretra foi 90% e 108% da dose de prescrição para I-125 e Pd-103, respectivamente. A D2cc para I-125 foi 30 Gy no reto e 127 Gy na bexiga, e para Pd-103 foi 29 Gy no reto e 189 Gy na bexiga. A D10 no osso do púbis foi 144 Gy para I-125 e 66 Gy para Pd-103. CONCLUSÃO: Os resultados indicam que os implantes de Pd-103 e I-125 puderam depositar a dose prescrita no volume alvo. Entre os achados, observou-se excessiva exposição de radiação nos ossos da pelve, principalmente no protocolo com I-125.

  20. Quality assurance program in the External dosimetry laboratory of the CPHR; Programa de aseguramiento de la calidad en el laboratorio de dosimetria externa del CPHR

    Molina P, D.; Pernas S, R.; Martinez H, E.; Cardenas H, J. [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41 y 47. Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba)

    2006-07-01

    From 1999 the Laboratory of External Dosimetry of the Radiation Protection and Hygiene Center comes applying in its service of personal dosimetry a Program of Quality Assurance. This program was designed according to the recommendations of national and international organizations as the National Assuring Office of the Republic of Cuba (ONARC), the International Standards Organization (ISO), the International Electro technique Commission (IEC) and the International Atomic Energy Agency (IAEA). In this work it is presented in a summarized way the operation of this Program of Quality Assurance which includes the administration and conservation of the results and the documentation of the service, the controls that are carried out to the equipment, the acceptance tests that are applied to the equipment and new dosemeters, the shipment and prosecution of the dosemeters, the evaluation, storage and conservation of the doses, the report of the results, the traceability and reproducibility of the measurements, the attention to the reclamations and the clients complaints and the internal and external audits to those that it undergoes periodically the laboratory. (Author)

  1. Kinetic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides; Proposicao de modelos cineticos e alometricos para a dosimetria de radiofarmacos marcados com lantanideos

    Lima, Marina Ferreira

    2012-07-01

    This work proposes two models based in compartmental analyses: Animal model and Human model, using images from gamma camera measurements to determinate the kinetic constants of the {sup 177}Lu-DOTATATE to three animal species (rat Wistar, Armenian hamster and Syrian hamster) and to the human in biodistribution studies split in two phases: Phase 1 governed by uptake from the blood and Phase 2 governed by the real excretion. The kinetic constants obtained from the animals' data ere used to build allometric scaling to predict radiopharmaceutical biodistribution in the human employing relations by mass, metabolism, by life span and by physiological parameters. These extrapolation results were compared with the PRRT (Peptide receptor radiotherapy) patients kinetic data calculated using the Human model. The kinetic constants obtained from humans were used in dose assessment to PRRT patients considering MIRD 26 organs and tissues. Dosimetry results were in agreement with available results from literature. For the Phase 1 allometric scaling from kinetic data from the blood to the organs straight responsible for the {sup 177}Lu-DOTATATE metabolism and excretion - liver, kidneys and urinary bladder -show good correlation in the scaling by mass, metabolism and physiological and parameters. For the Phase 2, only the kinetic data from blood to the liver and to the kidneys show good correlation. Based in the anaesthetics inhibitory action over the renal excretion, there is not empirical basis to allow measurement times over 40 minutes in in vivo studies with small animals. Consequently, the Phase 1 results seem enough to make allometric scaling to assessment dose in PRRT. (author)

  2. Validation criteria of an internal dosimetry laboratory in vivo; Criterios para la validacion de un laboratorio de dosimetria interna in vivo

    Alfaro L, M. de las M., E-mail: mercedes.alfaro@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    People working with radioactive materials, under certain circumstances (e.g. not using the proper protective equipment, an incident not covered, etc.) could be incorporated into the body. The radiation protection programs include direct measurement methods -in vivo- or indirect -in vitro- or both, to know that radioactive material is incorporated into the body. The monitoring measurements of internal contamination or (Radio-bioassay) are carried out with the purpose of determining the amount of radioactive material incorporated in the body; estimate the effective dose and committed dose; management administration of radiation protection; appropriate medical management; and to provide the data necessary for the legal requirements and the preservation of records. The measurement methods used in the monitoring of internal contamination must be validated by the combination of the following processes: calibration, using standards reference materials and/or simulators; execute systematic research, using control samples; and intercomparison between laboratories and performance tests. In this paper the validation criteria of an internal dosimetry laboratory in vivo are presented following the information provided by the standard ANSI N13-30-1996 and ISO/TEC 17025-2005 as are the criteria of facilities, staff training, interpretation of measurements, performance criteria for monitoring of internal contamination in vivo, results reporting and records retention. Thereby we achieve standardized quantitative performance criteria of truthfulness, accuracy and detection limit and a consensus on statistical definitions to establish the validation plan of a monitoring laboratory of internal contamination in vivo. (Author)

  3. Cytogenetics dosimetry: dose-response curve for low doses of X-ray; Dosimetria citogenetica: curva dosis-respuesta para bajas dosis de rayos-X

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon, E-mail: venovall.15@hotmail.com, E-mail: wrpineda@misena.edu.co, E-mail: vmpabonr@udistrital.edu.co [Universidad Distrital Francisco Jose de Caldas (UD), Bogota (Colombia). Grupo de Investigacion en Ciencia y Tecnologia Nuclear; Ureana, Cecilia Crane, E-mail: cecicrane@yahoo.com [Instituto Nacional de Salud (INS), Bogota (Colombia). Laboratorio de Genetica

    2013-07-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers.

  4. Alanine/RPE dosimetry in the process of blood irradiation; Dosimetria alanina/RPE en el proceso de irradiacion de sangre

    Chen, F.; Covas, D.T.; Baffa, O. [Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, 14040-901 Ribeirao Preto-SP (Brazil)

    2000-07-01

    A set of eighty dosemeters approximately of Dl- alanine was proportioned to the Hemo center of Hospital das Clinicas of Medicine Faculty at Ribeirao Preto (HC-FRMP) in the Sao Paulo University, with the purpose to realize a quality control of the radiation dose supplied to blood bags. These dosemeters were divided in eight groups and irradiated for a two months period.The dosemeters were adhered to the bags and arranged inside of an acrylic box filled water with dimensions: (40x40x20) cm{sup 3}. The box irradiation was made using two fields parallel-opposed of (40x40) cm{sup 2} at 80 cm distance source-surface, in the Radiotherapy Service of HC-FMRP, with a {sup 60} Co teletherapy unit. The irradiation time was sufficient to supply a dose of 20 Gy approximately in the box center. The RPE measures were realized in a Varian E-4 spectrometer operating in X-band. For the total of dosemeters and for the irradiation volume, the minimum and maximum doses were of 14 Gy and 23 Gy respectively. The mean dose was (18{+-}2) Gy (1 {sigma}), and the variability coefficient 11 %. Around 5 % of the bags received a dose under of the recommended limit by the Brazilian legislation and as consequence, the exposure time was increased. (Author)

  5. Reconstructive dosimetry of radiological accidents - study of a brazilian case of industrial gamma radiography; Dosimetria reconstrutiva de acidentes radiologicos - estudo de um caso brasileiro de gamagrafia industrial

    Silva, Francisco Cesar Augusto da; Hunt, John G.; Ramalho, Adriana [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Pinto, Livia M.F. Amalfi [ARCtest - Servicos Tecnicos de Inspecao e Manutencao Industrial Ltda., Paulinia, SP (Brazil)]. E-mail: protecao@arctest.com.br

    2002-07-01

    On May 2000, an industrial gamma radiography operator, during a maintenance work of a {sup 60}Co irradiator, has suffered a radiological accident with severe consequences to the left hand. The experts of the High Doses Analysis Group (GADE/IRD/CNEN) initiated the reconstructive dosimetry for the radiation dose estimation, in order to determine the real dose received by the operator, and to help the medical evaluation for prescribing the medical procedures for treatment of the involved victim. This paper presents the reconstructive dosimetry performed through the determination of the radiation doses of the operator, based on theoretical, experimental and computational methods. For the computer methods, a program for the calculation of external doses were used, based on the Monte Carlo method, and a human body simulator composed by voxels. The values of effective and equivalent doses are also presented which has caused severe lesions on the operator hand.

  6. Experience on IMRT treatment for prostate cancer. Planning, dosimetry and quality assurance; Experiencia en el tratamiento de IMRT en cancer de prostata. Planificacion, dosimetria y garantia de calidad

    Gomez Barrado, A.; Garcia Vicente, F.; Fernandez Bedoya, V.; Zapatero Laborda, A.; Fernandez, I.; Bermudez Luna, R.; Perez Gonzalez, L.; Torres Escobar, J. J.

    2011-07-01

    In this study a revision concerning the treatment of prostate cancer with intensity-modulated radiation therapy (IMRT) is performed. Planning and verification of treatments involving dose calculations and image positioning are considered. A set of 110 patients is analysed concerning dosimetry and 92 considering image verification. Dose calculation is verified both experimentally and by means of a monitor unit (MU) calculation system. Positioning control of the prostate is achieved using intraprostatic fiducial markers and digitally reconstructed radiographs (DRRs) as well as a home-made software. All patients studied were consistent with the specifications of the treatment protocol regarding dose prescription in planning target volume (PTV), organ at risk (OAR) dose limitations, dosimetric quality assurance and positioning control. The procedure includes a learning curve considering every aspect of the treatment. The MU calculation system itself has been proved as an effective and functional tool for treatment verification. (Author) 12 refs.

  7. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  8. Dosimetry of internal emitting: principles and perspectives of the MIRD technology; Dosimetria de emisores internos: principios y perspectivas de la metodologia MIRD

    Ferro F, G [Gerencia de Aplicaciones Nucleares en la Salud, Instituto Nacional de Investigaciones Nucleares, Salazar, Estado de Mexico C.P. 52045 (Mexico)

    1999-07-01

    The development of the radiopharmaceutical technology have multiplied the number of radioisotopes with applications in therapeutical nuclear medicine so known as Directed radiotherapy. Assuming the radiation is capable to produce noxious effects in the biological systems, it is important to evaluate appropriately the risks and benefits of the administration of radioactive agents in the patient. The outstanding parameter in this evaluation is the absorbed dose, which is product of the radiation emitted by a radionuclide that is localized or distributed to the interior of the human body in study and whose its estimation helps to predict the efficacy of the treatment. The scheme generalized of MIRD, it was formulated from thirty years ago for evaluating the interior dosimetry at level of organs.The finality of this work is to show the basic principles of the MIRD methodology and its perspectives using innovator tools as the dosimetry for dynamic masses, in particular the personnel dosimetry for the organs of each patient, the dosimetry for the small structures inside the organs (sub organic dosimetry), the distributions of doses in three dimensions (S voxel), the dosimetry at cellular level and the quantitative acquisition of pharmaceutical data. (Author)

  9. Direct detection of second harmonic and its use in alanine/EPR dosimetry; Deteccao direta do segundo harmonico e seu uso na dosimetria alanina/RPE

    Chen, F.; Guzman, C.S.; Graeff, C.F.O.; Baffa, O. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica]. E-mail: chen@dfm.ffclrp.usp.br

    2001-07-01

    In this work, the possible use of the second harmonic EPR signal from irradiated alanine for low radiation dose ({approx}1 Gy) was explored, aiming applications to HDR brachytherapy and teletherapy. The second harmonic signal was directly detected after overmodulation. A batch of DL-alanine/paraffin small cylindrical pellets was made. A VARIAN E-4 X-Band EPR spectrometer with optimized operation parameters like microwave power and modulation amplitude to obtain a signal with the highest amplitude was used. The modulation frequency and modulation amplitude were 100 kHz and 1.25 mT (to overmodulate the signal) respectively. The second harmonic signal was directly detected at twice the modulation frequency. One group of dosimeters was irradiated with a {sup 192} Ir brachytherapy source and the other in a 10 MeV X-rays linear accelerator, both group at a dose range: 0.5 - 15 Gy. The second harmonic signal showed better resolution than the first harmonic one making possible a more easy localization of the signal. Moreover, for both types of radiation, the dose-response curve showed a good linear behavior for the dose range indicated. (author)

  10. Annual course of retraining for the occupational exposure personnel of the laboratory of internal dosimetry; Curso anual de reentrenamiento para el POE del laboratorio de dosimetria interna

    Alfaro L, M.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2002-09-15

    The general objective of this report is to instruct the personnel in the basic concepts of radiological protection and in the Manual of Procedures of Radiological Safety of the Laboratory of Internal Dosimetry. Also, to exchange experiences during the activities that are carried out in the laboratory and in the knowledge of abnormal situations. The referred Manual consists of 14 procedures and 5 instructions which are listed in annex of this document. The content of this course consists of three topics: 1. Basic principles of radiological protection to reduce the received dose equivalent. 2. Use of radiation measurer equipment. 3. Emergency procedures of the laboratory of internal dosimetry. (Author)

  11. Thermoluminescent dosimetry in pediatric patients subjected to TAC cranium multi cutting studies; Dosimetria termoluminiscente en pacientes pediatricos sometidos a estudios de TAC multicorte de craneo

    Tabares V, M.J.; Azorin N, J. [UAM-Iztapalapa, 09340 Mexico D.F. (Mexico); Azorin V, J.C. [CICATA-IPN, 11500 Mexico D.F. (Mexico)]. e-mail: azorin@xanum.uam. mx

    2007-07-01

    Full text: In this work the doses to critical organs in pediatric patient subjected to studies of multi cutting skull tomography were determined. The study included patient smaller than 16. The used tomograph was a Siemens Somaton 16 plus multi cutting. The dosimetry one carries out with thermoluminescent dosemeters of LiF:Mg,Cu,P +Ptfe of national production. This dosemeters type was used due to it characteristics, such as low fading, equivalence with the tissue, easy handling and reading and independence of it answer with the radiation energy. The value of the absorbed doses in organs in the simple study results half of the obtained value in the contrasted study that which indicates that the CTDI{sub vol} is proportional to the dose to organ. In the case of the skull three-dimensional reconstruction tomography the CTDI{sub vol} was practically the same one that for simple tomography was practically; however, the doses to organs differed significantly. When comparing the TDI{sub vol} value of the three-dimensional reconstruction tomography with that of the contrasted tomography the obtained reason it was 1:2; however, the doses to organ didn't show the same relationship and the absorbed dose in the case of the thyroid gland was even bigger in the study of three-dimensional reconstruction. The value of the CTDI{sub vol} is a good indicator of the exposure factors selected for the tomographic exploration and it is useful for the determination of the effective dose, but it doesn't indicate the absorbed dose to organ. (Author)

  12. Dosimetry of the JS-6500 industrial irradiator for the irradiation of the PVC graduated flasks; Dosimetria del irradiador industrial JS-6500 para la irradiacion de probetas de PVC

    Castaneda F, A.; Carrasco A, H.; Martinez P, M.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The dosimetry of the JS-6500 AECL irradiator was realized, outside of the industrial transportation rails to know the dose distribution, as well as its dose speed. This one with the intention of exposing to gamma radiation; plastified PVC graduated flasks and evaluating their interweavement or degradation or both. This study of dosimetry was carried out by means of a theoretical and experimental evaluation in air atmosphere. The results allow to know the irradiation conditions of the PVC graduated flasks as well as those results prove that has not a significant difference among the obtained result as theoretical as experimentally due to that the obtained result in the theoretical evaluation is 2.62 KGy/h and the result for the case of the experimental evaluation is 2.74 KGy/h. (Author)

  13. Applications of the Monte Carlo simulation in dosimetry and medical physics problems; Aplicaciones de la simulacion Monte Carlo en dosimetria y problemas de fisica medica

    Rojas C, E. L., E-mail: leticia.rojas@inin.gob.m [ININ, Gerencia de Ciencias Ambientales, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-07-01

    At the present time the computers use to solve important problems extends to all the areas. These areas can be of social, economic, of engineering, of basic and applied science, etc. With and appropriate handling of computation programs and information can be carried out calculations and simulations of real models, to study them and to solve theoretical or application problems. The processes that contain random variables are susceptible of being approached with the Monte Carlo method. This is a numeric method that, thanks to the improvements in the processors of the computers, it can apply in many tasks more than what was made in the principles of their practical application (at the beginning of the decade of 1950). In this work the application of the Monte Carlo method will be approached in the simulation of the radiation interaction with the matter, to investigate dosimetric aspects of some problems that exist in the medical physics area. Also, contain an introduction about some historical data and some general concepts related with the Monte Carlo simulation are revised. (Author)

  14. Calibration of semiconductors diodes for in vivo dosimetry in total body irradiation treatments; Calibracao de diodos semicondutores para dosimetria in vivo em tratamentos de irradiacao de corpo inteiro

    Oliveira, Fernanda F.; Costa, Alessandro M.; Ghilardi Netto, Thomaz, E-mail: ferretti.oliveira@gmail.com [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Ciencias e Letras. Departamento de Fisica; Amaral, Leonardo L. [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2012-08-15

    This paper presents the results of in vivo dosimetry with p-type semiconductors diodes, EDP-15 (Scanditronix Wellhoefer) of two patients who underwent total body irradiation treatments, at Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto University of Sao Paulo (HCFMRP-USP). The diodes were well calibrated and the calibration factors were determined with the aid of a reference ionization chamber (FC065, IBA dosimetry, sensitive volume of 0.65 cm{sup 3}).The calibration was performed in a Total Body Irradiation (TBI) setup, using solid water phantoms. Different lateral thicknesses from one patient were simulated and then the calibration factors were determined by means of maximum depth dose readings (half of the lateral thickness). The response difference between diode readings and the prescribed dose for both treatments was below 4%. This difference is in agreement as recommended by International Commission on Radiation Units (ICRU), which is {+-}5%. (author)

  15. Study of the reliability of the TLDs reader in a Thermoluminescent dosimetry laboratory; Estudio de la constancia de la lectora de TLDs en un laboratorio de dosimetria termoluminiscente

    Silva F, J.C. da; Fonseca, H.G. da [Instituto de Radioprotecao e Dosimetria-IRD, Av. Salvador Allende s/n- CEP, 22780-160, Rio de Janeiro (Brazil)]. e-mail: Jfeital@ird.gov.br

    2006-07-01

    Acting from the beginning of the decade of 80 in a postal program called 'Dentistry Programs' the Institute of Radioprotection and Dosimetry (IRD) it makes an effort supported by the IAEA so that it can determine with security the reference levels for the diverse practices in radiodiagnostic, including the dentistry. The dentistry program that uses 4 TLDs of lithium fluorite (LiF 100) for evaluations of the doses and of the hemirreductor layer, until 1995 it had already verified close of 5529 X-ray equipment. This work accompanies the result of 3 main parameters (arbitrary reading, reference light and noise) of the reader Harshaw marks 5500, when it is used for routine readings of the TLDs that arrive in the dosimetry laboratory for the due ratings. Together with these TLDs 9 previously selected dosemeters of a certain dosemeters lot is placed with a percentage uncertainty of 3% (for 1 standard deviation). before them they were irradiated in an irradiator of Sr90/Y90 with a dose of approximately 5 mGy, they are treated thermally in an oven PTW it marks to 400 grades for 1 hour + 100 grades for 2 hours and 100 grades in 15 minutes after the irradiations. The referred methodology follows a procedure where they are distributed of 3 in 3 the chosen TLDs of the group of the 9, to the beginning, half and at the end among the total quantity of dosemeters read in the reading disk that it can read of a single time 50 dosemeters. Together with this 10 measurements of reference light and noise are made, data that are provided by the reader through the 'softer WinRem'. Finally the obtained results of reference light and noise, its are compared with the maker's recommendations. Already that of the arbitrary reading (average of the 9 TLDs and its uncertainties), it has revealed a reduction in the percentage uncertainty (2 deviations standard / average) with relationship to one of the first results already obtained through the methodology proposal. It has been, also, applied the statistical test (F of Snedecor) for the verification among the variance of the populations for these two samples. (Author)

  16. Dosimetry in Computed Tomography head and neck scans; Dosimetria em varreduras de Tomografia Computadorizada de cabeça e pescoço

    Gómez, A.M.L.; Santana, P.C.; Mourão, A.P., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais (UFMG), Berlo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Non-invasive diagnostic methods for X-rays, such as computed tomography (CT), have shown rapid growth in radiology services. There is concern about the radiation doses deposited in patients because the CT scans are the ones that contribute most to the dose increase in the population. The legislation for regulating patient dose levels only imposes an upper limit for a given test, depending on the region of the body to be irradiated. Therefore, it is necessary to know the dose values deposited in patients referring to routine protocols used in radiology services and propose an optimization of these according to the principles of radiological protection. Experiments were performed to determine the dose profile deposited in routine adult patient head scans using a male anthropomorphic simulator. Radiochromic film strips were introduced in the central region of the simulator to record the dose profile in the head and neck region and thus determine the air kerma values within the simulator object. Four scans were performed on a General Electric 64-channel tomograph programmed in helical mode and the scans were made with voltages of 80, 100 and 120 kV, and fixed current and automatic current control were used. The mean values recorded on the strips ranged from 14.82 to 22.98 mGy. Imaging noise analyzes were performed so that for all the scans the images obtained were considered of diagnostic quality and the Kerma values in the air when converted to absorbed dose are diagnostic parameters acceptable in the Brazilian legislation.

  17. Integrating techniques for neutron dosimetry in Linac 18 MV; Integrando tecnicas para dosimetria de neutrones en un Linac de 18 MV

    Ceron R, P. V.; Diaz G, J. A. I.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico); Paredes G, L. C. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this paper thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the neutron dose equivalent in a radiotherapy room with a linear electron accelerator of 18 MV. The equivalent dose was measured at isocenter to 1.42 m of target and at the entrance of the labyrinth of the room of a Novalis Tx. The neutron detectors were constructed with pairs of thermoluminescent dosimeters TLD 600 ({sup 6}LiF: Mg, Ti) and TLD 700 ({sup 7}LiF: Mg, Ti) which are placed inside a paraffin sphere of 20 cm in diameter. These measurements enabled the calculation of equivalent dose in the gate and the source term, using the relationships contained in the NCRP-151. Through the models carried out with the code MCNPX the absorbed dose distribution with regard to depth in a paraffin phantom are included and the neutron spectrum produced by the head, taking into account the geometry and component materials. The results are in the order of neutron milli sievert by gray of X-rays (mSv/Gy x) which are in the same order as those found in other reports for different accelerators. (Author)

  18. Electronic Paramagnetic Resonance of irradiated nails: challenges for a dosimetry in radiation accidents; Ressonancia Paramagnetica Eletronica de unhas irradiadas: desafios para uma dosimetria em acidentes radiologicos

    Giannoni, Ricardo A., E-mail: giannoni@ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rodrigues Junior, Orlando [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The purpose of this work is to characterize samples of human nails exposed to high doses of radiation, applying the technique of Electron Paramagnetic Resonance (EPR). The objective is to establish a dose response study that allow determine the absorbed dose by exposed individuals in situations of radiological accidents, in a retrospective form. Samples of human nails were collected and afterward irradiated with gamma radiation, and received dose of 20 Gy. The EPR measurement performed on the samples, before irradiation, permitted the signal identification of the components associated with effects caused by the mechanical stress during the fingernail cutting, the so-called mechanically induced signal (MIS). After the irradiation, different species of free radicals were identified, the so-called radiation induced signal (RIS). (author)

  19. Use of semiconductor diodes for dosimetry TomoTherapy Hi-Art unit; Utilizacion de diodos de semiconductor para la dosimetria de una unidad Tomotherapy Hi-Art

    Hernandez Rodriguez, J.; Garcia Repiso, S.; Martin Rincon, C.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Montes Fuentes, C.; Dena Espinel, E. de; Gomez Llorente, P. L.; Fernandez Bordes, M.

    2011-07-01

    The radiotherapy unit TIT-Art TomoTherapy allows the realization of intensity modulated treatments in a helical manner through design, consisting of a linear accelerator installed on a rotating gantry in combination with the longitudinal movement of the treatment table and a multi leaf collimator (MLC) binary. The acceptance tests include, among other things, the acquisition of a set of dosimetric data (profiles and PDD), for later comparison with a reference set of measures taken at the factory, called the gold standard. Being pre commissioning from the factory, the unit will be accepted provided that the measured data meet the gold standard within preset tolerances. The dosimetric equipment used in the test of acceptance is provided by the manufacturer and so far is done with water tank, camera, software electrometer and associate of Standard Imaging and marketed by TomoTherapy Inc. The objective of this study is to compare the measures obtained with a semiconductor diode with the gold standard. (Author)

  20. Dosimetria de pacientes e médicos em intervenções coronárias percutâneas em Recife, Pernambuco, Brasil

    Maria do Socorro Rocha da Silva

    2011-04-01

    Full Text Available OBJETIVO: Este trabalho teve como objetivo estimar os valores de doses de radiação recebidas por médicos e pacientes em procedimentos intervencionistas cardíacos realizados em um hospital público na cidade de Recife, Pernambuco. MATERIAIS E MÉTODOS: As medidas foram determinadas em 31 pacientes adultos, dos quais 22 tiveram acompanhamento clínico após o procedimento, e em dois cardiologistas com mais de dez anos de experiência. Parâmetros de irradiação para cada procedimento foram registrados. RESULTADOS: Os valores obtidos para a dose absorvida máxima na pele do paciente variaram entre 612 e 8.642 mGy, sendo que 53% foram maiores que 2.000 mGy, valores estes que podem causar efeitos determinísticos. Com relação aos médicos, a dose efetiva média por procedimento foi de 11 µSv e os valores médios do equivalente de dose nas extremidades, mais altos, foram: 923 µSv no pé esquerdo, 514 µSv no pé direito, 382 µSv na mão esquerda e 150 µSv no olho esquerdo. Dependendo do número de procedimentos, as doses recebidas pelos médicos podem exceder os valores limites de doses estabelecidos pelas normas nacionais e internacionais. CONCLUSÃO: Os resultados obtidos sinalizam a necessidade de adoção de estratégias para otimização da proteção radiológica tanto de pacientes quanto de médicos.

  1. Dosimetry of ultraviolet radiation with BaHfO{sub 3} powders; Dosimetria de radiacion ultravioleta con polvos de BaHfO{sub 3}

    Barrera A, A. A.; Aguilar D, G. A.; Guzman M, J.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Ceron R, V., E-mail: abalba1@hotmail.com [Universidad de Guanajuato, 37670 Leon, Guanajuato (Mexico)

    2016-10-15

    Ceramic materials based on pure barium hafnate (BaHfO{sub 3}) have been obtained as a powder by the co-precipitation method. The powders obtained have a cubic structure that favors the thermoluminescent and optical properties, through which a better detection of the non-ionizing radiation is allowed. With these powders various tests were performed in the ultraviolet range at different exposure times. These thermoluminescent (Tl) studies were carried out using a Tl 3500 hand held reader which yielded a brightness curve that ranged from room temperature to the 350 degrees Celsius. This BaHfO{sub 3} response exhibits a broad brightness curve with a single peak centered around 225 degrees Celsius. Finally, is reported that there are materials of barium hafnate (BaHfO{sub 3}) doped with some rare earths (Eu, Tb) which, instead of improving the performance of the powders, decrease it, so that the use of intrinsic barium hafnate is the most appropriate. (Author)

  2. Uncertainties in the dosemeter calibration used for dosimetry in mammography; Incertezas na calibração de dosímetros utilizados para dosimetria em mamografia

    Bianchi, Vivian C.R.N.; Evangelista, Claudete R.; Silva, Teógenes A. da, E-mail: vcrnb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    This study aims to detail the sources of uncertainties and to estimate the combined standard uncertainties associated with the calibration procedure of dosimeters to be used in the dosimetry of X-ray bundles in mammography. A RADCAL ionization chamber, model RC6-M, and the semiconductor dosimeters UNFORS Xi and RADCAL Digitizer AGDM Accul-Gold were used. The calibration coefficients in terms of air kerma and uncertainties were obtained for the reference radiations of the W-Mo target-filter combinations. (author)

  3. Application of the Electron paramagnetic resonance to the ionizing radiation dosimetry; Aplicacion de la Resonancia paramagnetica electronica a la dosimetria de las radiaciones ionizantes

    Urena N, F. [Instituto Nacional de Investigaciones Nucleares, Km. 36.5 Carretera Mexico-Toluca, 52045 Salazar, Estado de Mexico (Mexico)

    2000-07-01

    The Electron Paramagnetic Resonance (EPR) is defined as the resonant absorption of electromagnetic energy in paramagnetic substances by the spin transition of a non-pairing electron between different energy levels in presence of a magnetic field. (Slighter, 1989). One of the more important characteristic of EPR is that the electron spin levels are subdivided by the electron interaction with the magnetic dipoles of the nearby nucleus giving occasion for a spectral structure called hyperfine structure. In this kind of interactions two limit cases are distinguished: 1. when the non-pairing electron is located in a central ion surrounded of atoms belonging to coordinate molecules. 2. When a non-pairing electron interactioning in the same form with a number of equivalent nucleus, which is common in organic radicals, these will give as result spectra. Some EPR spectrometer can be used to dosimetric purposes by free radicals via. In this work, it is presented the application of EPR to dosimetry of ionizing radiations by free radicals via which allows to determinations of high doses. (Author)

  4. Analysis of the gamma criteria validation of dosimetric for VMAT; Analisis de los criterios gamma de validacion de dosimetrias para VMAT

    Sanchez Carrasco, M.; Marti Asenjo, J.; Torres Pozas, S.; Madan Rodriguez, C.; Luque Japon, L.; Godoy Cazorla, J.; Martin Olica, R.

    2013-07-01

    The simultaneous use of the variable elements of the patients, make it necessary to add a specific quality control for each treatment in addition to the quality controls newspapers of the machine. Likewise, the absence of an international or academic standard that a procedure for the validation of these treatments, justify the study of possible criteria for validation. Mannequins and computer programs used in this respect support a variety of analytical methods for the validation of the reproduction of the treatment. These methods of analysis are evaluated according to their sensitivity and specificity. (Author)

  5. Dosimetric pens: evaluation of calibration results in the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes do Instituto de Radioprotecao e Dosimetria (IRD/LNMRI), RJ, Brazil

    Quaresma, D.S.; Ramos, M.M.O.; Cabral, T.S.; Peixoto, J.G.P.

    2005-01-01

    Dosimetric pens are direct reading personal dosemeters that are used in the practices of radiation protection in industries, hospitals, universities, and research institutes in the country. Quality control of measurements made with these instruments must include their periodical calibration in one of the laboratories of the Calibration Laboratory Network for Ionizing Radiation with the aim to compare the behavior of the measurements made in dosimetric pens of different models and manufacturers, submitted for calibration in the LNMRI/IRD/CNEN (Brazilian Lab for Metrology of Ionizing Radiations of the Institute for Radioprotection and Dosimetry of the Brazilian Nuclear Energy Commission), RJ or national reference laboratory and a member of the Network, in the years of 2000 to 2002. The parameters considered for the purpose of this work were: accuracy and linearity of response and measurement uncertainty evaluated. The results show that among the analyzed models there are changes in behavior

  6. Electron dosimetry in irradiation processing with rad-hard diodes; Dosimetria de eletrons em processos de irradiacao com diodos resistentes a danos de radiacao

    Santos, Thais Cavalheri dos

    2012-07-01

    This work had the aim of the development of dosimetric systems based on Si special diodes, resistant to radiation damage to online monitoring of irradiation processing using 1.5 MeV electrons energy and for relative dosimetry and clinical electron beam scanning within an energy range of 6 MeV up to 21 MeV. The diodes used were produced by Float Zone standard (FZ), Magnetic Czochralski (MCz) and epitaxy growth (EPI) methods. In order to use the diodes as detectors, they were fixed on alumina base to allow the connection of the polarization electrodes and the signals extraction. After the diode assembly on the base, each one was housed in a black acrylic probe with aluminized Mylar Registered-Sign window and LEMO Registered-Sign connector. With the devices operating in photovoltaic mode, the integration of the current signals as a function of irradiation time allowed obtain the charge produced in the sensitive volume of each diode irradiated. The electron accelerator used for high doses irradiation was the DC 1500/25/4 JOB 188 of the 1.5 MeV installed at the Radiation Technology Center of the IPEN/CNEN-SP. The current profile as function of exposure time, the response repeatability, the sensitivity as function of absorbed dose and the dose response curve were studied for each device. In comparison to FZ diode, we observed a greater decrease in the sensitivity for MCz diode, and good repeatability in both cases. Also, the increasing of the charge with the absorbed dose was well fitted by a second order polynomial function. In the EPI diode characterization, this one exhibited repeatability better than CTA dosimeters applied routinely in radiation processing. The above results indicate the potential use of these radiation hardness Si diodes in online dosimetry to high doses applications. For low doses irradiation were used the linear accelerators KD2 and Primus, both manufactured by Siemens and located at Sirio-Libanes Hospital. The diodes responses were evaluated for electron beams within the energy range of 6 MeV up to 21 MeV. The following studies were carried out: the short-term repeatability, the dose-response curve as a function of absorbed dose, the charge sensitivity as function of electron beam energy, the percentage depth dose (PPD) and the dose transversal profile. Despite the response of the diodes FZ, MCz and EPI be slightly dependent on the electron beam energy, the dosimetric response was linear in all electron beam energy range studied. In addition to this, the EPI devices showed excellent agreement with simulation performed with Monte Carlo code and the measurements performed with MatriXX Registered-Sign , confirming that the devices can be used as dosimeters in radiotherapy for scanning purposes, dose distribution mapping, constancy monitoring of calibration factor and relative dosimetry. (author)

  7. Characterization of an electronic system for Image acquisition portal to open field dosimetry; Caracterizacao de um sistema eletronico de aquisicao de imagem portal para dosimetria em radioterapia

    Barbi, Gustavo L.; Oliveira, Harley F.; Bertucci, Edenyse C.; Amaral, Leonardo L.; Borges, Leandro F., E-mail: gustavobarbi@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica

    2012-08-15

    The objective was to characterize and enable an electronic portal imaging device (EPID) to use like a portal dosimetry device - PDI, in non-transit mode, without interposition of scattering between the beam and EPID for measurement to open fields. The images as well as the DICOM header data are extracted from software ImageJ and the information are used in the basic algorithm for converting pixel to dose. The linearity and reproducibility of response were analyzed, and the maximum deviation found of 2,3% to 800 monitor units (MU) for linearity and -0,9% for reproducibility of signal measured daily. A 512x512 matrix with a resolution of 0,8mm was established to restore the shape of beam from the image. The field size dependence was evaluated, by obtaining the ratio of total scattering of ionization chamber and EPID. Finally, a calibration factor of 28470.88{+-}170.73 pixel/cGy was established for the central area of the image. Comparative analyzes between the PDI, radiochromic film and array of ionization chambers (MatriXX) showed good agreement for fields greater then 5 x 5 cm{sup 2} to reestablishment of form field and dose, however, for fields between 3x3 cm{sup 2} and 5x5 cm{sup 2}, the agreement to shape of beam was best established by film. (author)

  8. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Gonzalez M, P R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  9. Thermoluminescent properties of ZrO{sub 2}:Mn for UV light dosimetry; Propiedades termoluminiscentes de ZrO{sub 2}:Mn para dosimetria de la luz UV

    Rivera M, T. [Universidad Autonoma Metropolitana Iztapalapa, Deparatmento de Fisica, 09340 Mexico D.F. (Mexico); Azorin N, J. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Falcony G, C. [CINVESTAV-IPN, Departamento de Fisica, 07300 Mexico D.F. (Mexico); Martinez, E.; Garcia, M. [Universidad Nacional Autonoma de Mexico, Instituto de Investigaciones en Materiales, 04510 Mexico D.F. (Mexico)

    1999-07-01

    The main source of ultraviolet light (UV) to whom is exposed the population is the one coming from the Sun, although exist some artificial sources too. The UV light can be classified in UV A (315-400)nm, in UV B (180-315) nm and UV C (100-180) nm. In this work are presented the results studying in the thermoluminescent characteristics of ZrO{sub 2}: Mn for the UV dosimetry. The studied dosimetric characteristics were: concentration effect of the doping material, erased thermal treatment, posterior thermal treatment to the irradiation, Tl curve, response in function to the wavelength, response in function to the dose and reproducibility. Finally, presenting results highly promisers for the UV light dosimetry. (Author)

  10. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons; Camara de ionizacao de eletretos: um novo metodo para deteccao e dosimetria de neutrons termicos

    Ghilardi, A J.P.

    1988-12-31

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of {gamma}-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF{sub 3} ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs.

  11. Development of a calorimetric system for electron beam dosimetry in radiation processing; Desenvolvimento de um sistema calorimetrico para dosimetria de feixe de eletrons em processos por radiacao

    Banados P, H E

    1994-12-31

    A calorimetric system for electron beam dosimetry in radiation processing was developed. The system is composed of a graphite core calorimeter, the temperature measuring and electrical calibrating instrumentation, a microcomputer and the software for the system automation. The research aimed at the optimization of the project parameters, the development of advanced methodologies for calibrating the temperature sensor, the determination of the thermal capacity as a function of the temperature, the measurement of the absorbed dose, and the development of the software needed for the system operation. The operating range extends from 0.1 kGy to 30 kGy. The uncertainty in the measurement of the absorbed dose was estimated to be {+-} 1.8% at the 95% confidence level. Comparative tests of the absorbed dose measurements were made using the IPEN electron accelerator. The results obtained showed an excellent agreement between the absorbed dose determined by the calorimeter and the absorbed dose calculated from the nominal power delivered by the accelerator. (author). 67 refs, 63 figs, 2 tabs.

  12. Chromosomal analysis and application of biological dosimetry in two cases of apparent over exposure; Analisis cromosomico y aplicacion de la dosimetria biologica en dos casos de aparente sobreexposicion

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, ININ A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The gamma radiation calibration curve of {sup 60} Co is used which was generated in the ININ Laboratory of Biology to calculate the exposure dose of two workers whose dosemeters marked values above of the limit allowed. The analysis indicates that in a first case, the aberrations frequency corresponded to the basal value, therefore there is not over exposure. The aberrations frequency of the second case is lightly above to the basal value and therefore the probability favors to what the physical dosimetry indicates. (Author)

  13. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Romero, A. M.; Saez, J. C

    1994-07-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  14. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Romero, A.M.; Saez, J.C.

    1994-08-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  15. Dosimetry of the Occupational Exposure Personnel and not exposure of the INNSZ; Dosimetria del Personal Ocupacionalmente Expuesto (POE) y no expuesto del INNSZ

    Ruiz J, A [Departamento de Medicina Nuclear, Instituto nacional de la nutricion Salvador Zubiran, Mexico D.F. C.P. 14100 (Mexico)

    1999-07-01

    In this work, was measured the equivalent dose of all the personnel of Nuclear medicine and personnel of the Institute which by its activities remain in the Department, by time determined, through thermoluminescent dosemeters and the results were that the personnel presents variable equivalent dose and it is proportional to the time and radionuclide type which use for their work. By this it is allowed to secure what the work watched with respect to radiological protection to fulfil with the International Standards standing for personnel in the Institute. (Author)

  16. Reduction in relapse rate of radioiodine therapy in patients of toxic multinodular goiter: A quality improvement project

    Mitra, Sujata; Muthu, Sonai G

    2012-01-01

    Introduction: Radioiodine (I-131) therapy is the definitive treatment of toxic multinodular goiter (TMNG). Treatment failure may result in relapse after I-131 therapy. The present study was undertaken to reduce treatment failure rate of I-131 therapy in TMNG patients. Materials and Methods: Multiple causes may have lead to treatment failure of I-131 in TMNG patients making it difficult to establish a direct cause?effect relationship and take corrective action. Therefore, the JURAN methodology...

  17. Evaluation of the processes used for the treatment of the hospitable radwastes containing Cs-137

    Peres, S.S.; Silva, J.J.G.

    1988-01-01

    This work presents a resume of results obtained in the treatment of radwastes containing Cs-137 from HNMD (Hospital Naval Marcilio Dias) and IRD (Instituto de Radioprotecao e Dosimetria), due to the radiological accident of Goiania. (author) [pt

  18. Seleção de critérios para a especificação de pastas celulósicas branqueadas de eucaliptos na fabricação de papéis para impressão “offset”

    Edison da Campos Silva

    2000-01-01

    Full Text Available The purpose of this work was to analyze the characteristics of some eucalypts pulps available in the market, aiming to understand their influence in the properties of the offset papers. Another objective of this work was to show alternatives to reduce the number of laboratory tests in the pulp specifications. Thirteen (13 market pulps (Brazilian and international pulps were analyzed and the tests applied were as follows: intrinsic viscosity, alkali solubility at 5%, coarseness, numbers of fibers per gram of pulp, average length of fibers, fine fraction by the Dynamic Paper Chemistry Jar (DPCJ, drainability by Schopper Riegler, before refining. Other tests, such as: tensile index, stretch, burst index, tear index, bulk, air resistance, opacity and absorption of water by cappilarity (Klemm were performed for each type of pulp before refining and for refining levels of 25 ºSR, 30 ºSR, 40 ºSR and 55 ºSR. No evidence of the influence of S5 and intrinsic viscosity was observed at the range of the market pulp properties variation. The Brazilian pulps presented higher initial drainability and required lower PFI revolutions to the same level of refining in comparison to the international pulps. The initial average values of strength indexes: tensile, stretch, burst and tear were higher to the Brazilian pulps. However, this situation was changed at 25 ºSR and other levels of drainability. Due to the higher number of correlations at 30 ºSR, this level of drainability was chosen to determine the pulp characteristics profile. At this level, international pulps showed better values of tensile and tear index, but a higher energy consumption and a lower opacity in comparison to the Brazilian pulps. In addition, this paper suggested the concentration of the lab technical evaluation of pulps on the analysis of opacity, tensile and tear indexes. Such procedure should reduce the number of lab tests as well.

  19. Stability of an anaerobic reactor with support means in the treatment of cassava through the monitoring of relationship AV/AT specific and production of biogas; Estabilidade de um reator anaerobio com meio suporte no tratamento da manipueira atraves do monitoramento da relacao AV/AT e producao especifica de biogas

    Kunzleri, Kathia; Watthier, Elisangela; Gomes, Simone D.; Miguel, Joao F.A. [Universidade Estadual do Oeste do Parana (UNIOESTE), Cascavel, PR (Brazil); Andreani, Cristina Lurdes [Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq), Brasilia, DF (Brazil)

    2010-07-01

    This study aimed to evaluate the removal of different organic loading in an anaerobic reactor for treatment of cassava wastewater, and as a medium bamboo rings. Cassava wastewater study is derived from a starch industry. The wastewater was characterized following the method described in Standard Methods for Examination of Water and Wastewater. The reactor was constructed of PVC, with a volume of 6.8 liters. The results were evaluated by variance analysis (parametric ANOVA) using the software Statistica 7.0. We observed a higher yield for the charge of 5, 601 (4) gDQO / L day, the ratio av/at was below 0.5 thus ensuring system stability. (author)

  20. The synthesis of the insecticides Aldrin and Dieldrin labelled with carbon-14 at high specific activity; Synthese des insecticides aldrine et dieldrine marques au carbone-14 de haute activite specifique; Sintez insektitsidnogo aldrina i dildrina, mechennykh uglerodom-14 pri vysokoj udel'noj aktivnosti; Sintesis de los insecticidas aldrin y dieldrin de elevada actividad especifica marcados con carbono-14

    Thomas, Daniel J; Kilner, A Edward [Radiochemical Centre, UKAEA, Amersham, Bucks (United Kingdom)

    1962-03-15

    Aldrin is the trade name given by Shell Chemicals to 1, 2, 3, 4, 10, 10-hexachloro-1, 4, 4a, 5, 8, 8a-hexahydro-exo-1, 4-endo-5, 8-dimethanonapthalene. Acetylene-1, 2-C{sup 14} is converted successively to tetrachloroethane and trichloroethylene, and this is condensed with carbon tetrachloride by the Prins reaction in the presence of aluminium chloride to octachlorocyclopentene. Dechlorination gives hexachlorocyclopentadiene which undergoes a Diels-Alder addition to bicyclo(2, 2, 1) hepta-2,5-diene to give aldrin-C{sup 14} in 12% yield from barium carbonate. Oxidation of Aldrin gives the 6,7 epoxide, Dieldrin, in 87% yield. The paper includes an account of the separation of octachlorocyclopentene from the crude product of the Prins reaction by gas-liquid chromatography and of the separation of Aldrin and Dieldrin on a small preparative scale by reversed-phase paper chromatography. (author) [French] Aldrine est la denomination commerciale par laquelle la Shell Chemicals designe l'hexachloro-1, 2, 3, 4, 10, 10-hexahydro-1, 4, 4a, 5, 8, 8a-exo-endo-1,4- dimethano-5, 8-naphtalene. L'acetylene-1,2-C{sup 14} est successivement transforme en terachloroethane et en trichloroethylene, lequel se condense avec le tetrachlorure de carbone, par la reaction de Prins, en presence de chlorure d'aluminium, pour donner de l'octachlorocyclopentene. La dechloruration fournit de l'hexachlorocyclopentadiene, lequel, par une synthese de Diels-Alder, se transforme en bicyclohepta(2, 2, 1)-diene-2, 5 pour donner de l'aldrine-C{sup 14}, avec un rendement de 12% par rapport au carbonate de baryum. L'oxydation de l'aldrine donne l'epoxyde-6 7-(dieldrine), avec un rendement de 87%. Les auteurs decrivent, en outre, la separation de l'octachlorocyclopentene par chromatographie gaz-liquide, a partir du produit brut de la reaction de Prins, ainsi que la separation de l'aldrine et de la dieldrine, en petite quantite, par chromatographie sur papier a phase renversee. (author) [Spanish] Aldrin es el nombre comercial que la compania Shell Chemicals dio al 1, 2, 3, 4, 10, 10-hexacloro-1, 4, 4a, 5, 8, 8a-hexabidro-exo-1, 4-endo-5, 8-dimetanonaftaleno. El acetileno-1, 2-{sup 14}C se convierte primero en tetracloroetano y despues en tricloroetileno, y este se condensa con tetracloruro de carbono, por la reaccion de Prins, en presencia de cloruro de aluminio, para dar octaclorociclopenteno. Por decloracion se obtiene hexaclorociclopentadieno que, por una sintesis de Diels-Alder, da biciclo (2, 2, 1) hepta-2, 5-dieno para llegar al aldrin-{sup 14}C con un rendimiento del 12% referido al carbonato de bario. La oxidacion del aldrin da el 6, 7-epoxido, denominado dieldrin, con un rendimiento del 87%. Los autores describen la separacion del octaclorociclopenteno del producto bruto de la reaccion de Prins por cromatografia gas-liquido, y la separacion del aldrin y del dieldrin en pequena escala, por cromatografia sobre el papel, de fase invertida. (author) [Russian] Aldrin - kommercheskoe nazvanie, dannoe SHellom Kemikalom dlya 1 ,2, 3, 4, 10, 10-geksakhloro-1, 4, 4a, 5, 8, 8a-geksagidro ehkso-1,4-ehndo-5,8-dimetanonaftalina. Atsetilen-1,2-C{sup 14} uspeshno prevrashchaetsya v tetrakhloroehtilen i trikhloroehtilen i kondensiruetsya s uglerodistym tetrakhloridom v reaktsii Prinsa v prisutstvii alyuminievogo khlorida v oktakhlorotsiklopentan. Dekhlorizatsiya privodit k geksakhlorotsiklopentadinu, kotoryj dobavlyaetsya v vide Dils-Aldera k bitsiklo (2, 2, 1) gepta-2,5-dinu dlya polucheniya iz barievogo karbonata 12% aldrina-C{sup 14}. Okislenie aldrina privodit k obrazovaniyu ehloksida 6,7 i dildrina v razmere 87%. V dokumente soderzhitsya otchet ob otdelenii oktokhlorotsiklopentana ot syrogo produkta reaktsii Prinsa putem gazozhidkoj khromatografii i ob otdelenii aldrina i dildrina v nebol'shom kolichestve putem obratnoj fazy bumazhnoj khromatografii. (author)

  1. Use of LabSOCS for determination of specific concentrations of {sup 40}K, {sup 238}U and {sup 232}Th in fertilizer samples; Uso de LabSOCS no calculo da eficiencia de detecao para determinacao da concentracao especifica de {sup 40}K, {sup 238}U e {sup 232}Th em amostras de fertilizantes

    Garcez, Ricardo Washington Dutra; Lopes, Jose Marques; Silva, Ademir Xavier da, E-mail: rgarcez@con.ufrj.br, E-mail: marqueslopez@yahoo.com.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Domingues, Alessandro Mariano; Lima, Marco Frota, E-mail: slessandrodomingues@fisica.if.uff.br, E-mail: marcofrotalima@yahoo.com.br [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Instituto de Biologia

    2015-07-01

    Use of fertilizer is an established practice worldwide to promote agricultural productivity increased without increasing the planted area, resulting in native forests protection and increase of the food availability. Some kinds of fertilizer have in their chemical composition some radionuclides due the origin of its feedstock, such as {sup 238}U, the {sup 232}Th, and their descendants, beyond {sup 40}K. Knowledge of the radioactivity levels in the environment is great importance to know the gamma radiation dose that the human being is exposed. For identification and quantitation of radionuclides, it was used gamma spectrometry where HPGe detector was used to obtain the spectra, and LabSOCS software for calculating the detection efficiency for each energy. The values of {sup 232}Th specific concentrations ranged from 4.1 to 368.1 Bq.Kg{sup -1} , the values of {sup 238}U specific concentrations ranged from 16.0 to 647.7 Bq.Kg{sup -1} and {sup 40}K specific concentrations ranged from 19.1 to 12713 Bq.Kg{sup -1} . Concentrations of values are consistent with those found in literature. (author)

  2. Determination of specific activities of U-238, Ra-226, Ra-228 e Th-228 in samples of mineral fertilizers with phosphorus; Determinacao das atividades especificas de U-238, Ra-226, Ra-228 e Th-228 em amostras de fertilizantes minerais com fosforo

    Garcez, R.W.D.; Lopes, J.M.; Silva, A.X. da, E-mail: rgarcez@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharoa (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Domingues, A.M.; Lima, M.A.F. [Universidade Federal Fluminense (UFF),Niteroi, RJ (Brazil)

    2016-07-01

    Samples were analyzed by gamma spectrometry mineral fertilizers with the HPGe detector and aid LabSOCS software for calculating the detection efficiency curve. Specific activities found for Pa-234m, Ra-226, Ra-228 and Th-228 in samples of phosphate fertilizers were 505 Bq.kg{sup -1}, 458 Bq.kg{sup -1}, 450 Bq.kg{sup -1} and 394 Bq.kg{sup -1}, respectively. And for the NPK fertilizer samples were found average values of 390 Bq.kg{sup -1}, 252 Bq.kg{sup -1}, 280 Bq.kg{sup -1} and 268 Bq.kg{sup -1}, respectively. (author)

  3. Assessment of iodine-131 transfer to cow's milk and to man resulting from the Nevada weapons tests of the 1950's

    Bouville, A.; Wachholz, B.W.; Dreicer, M.; Beck, H.L.

    1988-01-01

    The main pathway to man from fallout I-131 is, for most individuals, via the grass-cow-milk chain. In order to assess I-131 exposures for persons in each county of the contiguous U.S. the following estimates must be made : the activities of I-131 deposited on soil and pasture grass, the resulting I-131 concentrations in cow's milk, and the quantity of I-131 ingested by man. The most significant atmospheric weapons tests with respect to fallout occurred in the 1950's, during which time most of the monitoring of environmental radioactivity consisted of gross beta or gamma measurements. Assessments of exposures due to I-131 can be inferred from the original measurements of gross beta or gamma activity, from current or past measurements of radionuclides other than I-131, or from mathematical models

  4. Biokinetics and dosimetry in patients of {sup 99m}Tc-HYNIC-Lys{sup 3}-Bombesin: images of GRP receptors; Biocinetica y dosimetria en humanos de {sup 99m}Tc-HYNIC-Lys{sup 3}-Bombesina: imagenes de receptores GRP

    Santos C, C L [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2007-07-01

    The bombesin (BN) receptor subtype 2 (GRP-r) is expressed in several normal human tissues and is over-expressed in various human tumors including breast, prostate, small cell lung and pancreatic cancer. Recently [{sup 99m}Tc]EDDA/HYNIC-Lys{sup 3}-bombesin ({sup 99m}Tc-HYNIC-BN) was reported as a radiopharmaceutical with high stability in human serum, specific cell GRP-r binding and rapid cell internalization. The aim of this study was to evaluate the feasibility of using {sup 99m}Tc-HYNIC-BN to image GRP-r and to assess the radiopharmaceutical biokinetics and dosimetry in 4 breast cancer patients and in 7 healthy women. Methods: Whole-body images were acquired at 20, 90, 180 min and 24 h after {sup 99m}Tc-HYNIC-BN administration. Regions of interest (ROIs) were drawn around source organs on each time frame. The same set of ROIs was used for all 11 scans and the cpm of each ROI was converted to activity using the conjugate view counting method. The image sequence was used to extrapolate {sup 99m}Tc-HYNIC-BN time-activity curves in each organ in order to calculate the total number of disintegrations (N) that occurred in the source regions, according with MIRD methodology. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. Results: Images showed a rapid radiopharmaceutical blood clearance with renal excretion as predominant route. {sup 99m}Tc-HYNIC-BN exhibited high in vivo affinity for GRP-r over-expression successfully visualized in cancer mammary glands and well differentiated from the ubiquitous GRP-r expression in normal breast, lungs and airways. There was no statistically significant difference (p > 0.05) in the radiation absorbed doses between cancer patients and healthy women. The average equivalent doses (n=11) for a study using 740 MBq were 24.8 +- 8.8 mSv (kidneys), 7.3 +- 1.8 mSv (lungs), 6.5 +- 4.0 mSv (breast) 2.0 +- 0.3 mSv (pancreas), 1.6 +- 0.3 mSv (liver), 1.2 +- 0.2 mSv (ovaries) and 1.0 +- 0.2 mSv (red marrow). The mean effective dose was 3.3 +- 0.6 mSv. Conclusions: The highest absorbed dose variability was found in breast tissues because of differences in the in vivo affinity for GRP-r over-expression. All the absorbed doses are comparable with that known for most of the {sup 99m}Tc studies. In spite of the ubiquitous GRP-r expression in non-neoplastic tissues {sup 99m}Tc-HYNIC-BN is as a promising imaging radiopharmaceutical to target site-specific early breast cancer. These results warrant a further clinical study. (Author)

  5. Internal dose assessment in nuclear medicine: fetal doses due to radiopharmaceutical administration to the mother; Dosimetria interna en medicina nuclear: dosis absorbida en el feto por la administracion de radiofarmacos a la madre

    Rojo, Ana M; Michelin, Severino C

    2004-07-01

    The objective of this publication is to present a guideline for the dose assessment through a comprehensive introduction of knowledge on ionizing radiation, radiation protection during pregnancy and fetal dosimetry for physician and other professionals involved in nuclear medicine practices. It contains tables with recommended dose estimates at all stages of pregnancy for many radiopharmaceuticals. Compounds for which some information was available regarding placental crossover are shown in shaded rows. It includes the most common diagnostic and therapy practices in nuclear medicine considering the four radioactive isotopes selected: {sup 99m}Tc, {sup 131}I, {sup 201}Tl and {sup 67}Ga. There is a special case included, it is when conception occurs after the iodine has been administered. In almost every case, the diagnostic benefit to the mother outweighs the risk of any irradiation of the fetus. However, there is one situation in which severe fetal injury can be incurred from administering a radiopharmaceutical to the mother, and that is use of iodine-131 therapy for ablation of the thyroid in cases of hyperthyroidism or carcinoma. Radioactive iodine readily crosses the placenta and concentrates in the fetal thyroid, where, because of its small organ mass, high radiation doses are received. (author)

  6. Radiological protection in pelvis studies by computed tomography in Rando phantom by means of thermoluminescent dosimetry; Proteccion radiologica en estudios de pelvis por tomografia computada en fantoma Rando mediante dosimetria termoluminiscente

    Madrid G, O. A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Calz. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin N, J., E-mail: riveramt@hotmail.com [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2011-11-15

    The risks of the radiation in computed tomography (CT) studies have been recently reported in many works. Caution should be had in the environment of the exploration in the patient. To maintain the radiation doses so low as is reasonably possible during the CT examination, is important that in the CT the parameters are correctly adjusted for each patient with the purpose of having the minimum dose in the application of the study. Thermoluminescent dosimeters were used to measure the absorbed dose and to measure the CT profiles of dose. The distribution of the dose in the CT abdominal examination in the simulated patients was evaluated. The exploration parameters of the CT were 130 kV, 90 m A, with a cut thickness of 3 mm and a field of 1.0 in the pitch. The assignment dose was increased in an axis along the direction of the study, they were also studied. The equivalent dose due to the direct and dispersed radiation was determined during the procedures of the irradiation in pelvis examinations, for the next areas to the study like is in specific the critical organ (gonads) that is the terminal area of the exploration. Duri